Choi, Woosung; Min, Kyungmin; Kim, Chaehoon; Ko, Young Soo; Jeon, Jae Wan; Seo, Hwimin; Park, Yong-Ki; Choi, Minkee
2016-01-01
Amine-containing adsorbents have been extensively investigated for post-combustion carbon dioxide capture due to their ability to chemisorb low-concentration carbon dioxide from a wet flue gas. However, earlier studies have focused primarily on the carbon dioxide uptake of adsorbents, and have not demonstrated effective adsorbent regeneration and long-term stability under such conditions. Here, we report the versatile and scalable synthesis of a functionalized-polyethyleneimine (PEI)/silica adsorbent which simultaneously exhibits a large working capacity (2.2 mmol g−1) and long-term stability in a practical temperature swing adsorption process (regeneration under 100% carbon dioxide at 120 °C), enabling the separation of concentrated carbon dioxide. We demonstrate that the functionalization of PEI with 1,2-epoxybutane reduces the heat of adsorption and facilitates carbon dioxide desorption (>99%) during regeneration compared with unmodified PEI (76%). Moreover, the functionalization significantly improves long-term adsorbent stability over repeated temperature swing adsorption cycles due to the suppression of urea formation and oxidative amine degradation. PMID:27572662
Air separation with temperature and pressure swing
Cassano, Anthony A.
1986-01-01
A chemical absorbent air separation process is set forth which uses a temperature swing absorption-desorption cycle in combination with a pressure swing wherein the pressure is elevated in the desorption stage of the process.
PLSS Scale Demonstration of MTSA Temperature Swing Adsorption Bed Concept for CO2 Removal/Rejection
NASA Technical Reports Server (NTRS)
Iacomini, Christine S.; Powers, Aaron; Paul, Heather L.
2009-01-01
Metabolic heat regenerated temperature swing adsorption (MTSA) incorporated into a portable life support system (PLSS) is being explored as a viable means of removing and rejecting carbon dioxide (CO2) from an astronaut s ventilation loop. Sorbent pellets used in previous work are inherently difficult to quickly heat and cool. Further, their use in packed beds create large undesirable pressure drop. Thus work has been done to assess the application and performance of aluminum foam wash coated with a layer of sorbent. A to-scale sorbent bed, as envisioned studying use by a Martian PLSS, was designed, built, and tested. Performance of the assembly in regards to CO2 adsorption and pressure drop were assessed and the results are presented.
DOT National Transportation Integrated Search
2016-04-01
Todays environment is increasingly hostile to bridge decks with exposure : to deicing salts and environmental factors such as large temperature swings : and polluting chemicals. Being subjected to the most severe loading of all the : bridge compon...
Thermal control on the lunar surface
NASA Technical Reports Server (NTRS)
Walker, Sherry T.; Alexander, Reginald A.; Tucker, Stephen P.
1995-01-01
For a mission to the Moon which lasts more than a few days, thermal control is a challenging problem because of the Moon's wide temperature swings and long day and night periods. During the lunar day it is difficult to reject heat temperatures low enough to be comfortable for either humans or electronic components, while excessive heat loss can damage unprotected equipment at night. Fluid systems can readily be designed to operate at either the hot or cold temperature extreme but it is more difficult to accomodate both extermes within the same system. Special consideration should be given to sensitive systems, such as optics and humans, and systems that generate large amounts of waste heat, such as lunar bases or manufacturing facilities. Passive thermal control systems such as covers, shades and optical coatings can be used to mitigate the temperature swings experienced by components. For more precise thermal control active systems such as heaters or heat pumps are required although they require more power than passive systems.
Carbon dioxide separation using adsorption with steam regeneration
Elliott, Jeannine Elizabeth; Copeland, Robert James; Leta, Daniel P.; McCall, Patrick P.; Bai, Chuansheng; DeRites, Bruce A.
2016-11-29
A process for separating a carbon dioxide from a gas stream is disclosed. The process can include passing the gas stream over a sorbent that adsorbs the carbon dioxide by concentration swing adsorption and adsorptive displacement. The sorbent can be regenerated and the carbon dioxide recaptured by desorbing the carbon dioxide from the sorbent using concentration swing adsorption and desorptive displacement. A carbon dioxide separation system is also disclosed. Neither the system nor the process rely on temperature swing or pressure swing adsorption.
Swing-free transport of suspended loads. Summer research report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basher, A.M.H.
1996-02-01
Transportation of large objects using traditional bridge crane can induce pendulum motion (swing) of the object. In environments such as factory the energy contained in the swinging mass can be large and therefore attempts to move the mass onto target while still swinging can cause considerable damage. Oscillations must be damped or allowed to decay before the next process can take place. Stopping the swing can be accomplished by moving the bridge in a manner to counteract the swing which sometimes can be done by skilled operator, or by waiting for the swing to damp sufficiently that the object canmore » be moved to the target without risk of damage. One of the methods that can be utilized for oscillation suppression is input preshaping. The validity of this method depends on the exact knowledge of the system dynamics. This method can be modified to provide some degrees of robustness with respect to unknown dynamics but at the cost of the speed of transient response. This report describes investigations on the development of a controller to dampen the oscillations.« less
Apparatus for thermal swing adsorption and thermally-enhanced pressure swing adsorption
Wegeng, Robert S.; Rassat, Scot D.; Stenkamp, Victoria S.; TeGrotenhuis, Ward E.; Matson, Dean W.; Drost, M. Kevin; Viswanathan, Vilayanur V.
2005-12-13
The present invention provides compact adsorption systems that are capable of rapid temperature swings and rapid cycling. Novel methods of thermal swing adsorption and thermally-enhanced pressure swing adsorption are also described. In some aspects of the invention, a gas is passed through the adsorbent thus allowing heat exchangers to be very close to all portions of the adsorbent and utilize less space. In another aspect, the adsorption media is selectively heated, thus reducing energy costs. Methods and systems for gas adsorption/desorption having improved energy efficiency with capability of short cycle times are also described. Advantages of the invention include the ability to use (typically) 30-100 times less adsorbent compared to conventional systems.
Method for thermal swing adsorption and thermally-enhanced pressure swing adsorption
Wegeng, Robert S.; Rassat, Scot D.; Stenkamp, Victoria S.; TeGrotenhuis, Ward E.; Matson, Dean W.; Drost, M. Kevin; Viswanathan, Vilayanur V.
2003-10-07
The present invention provides compact adsorption systems that are capable of rapid temperature swings and rapid cycling. Novel methods of thermal swing adsorption and thermally-enhanced pressure swing adsorption are also described. In some aspects of the invention, a gas is passed through the adsorbent thus allowing heat exchangers to be very close to all portions of the adsorbent and utilize less space. In another aspect, the adsorption media is selectively heated, thus reducing energy costs. Methods and systems for gas adsorption/desorption having improved energy efficiency with capability of short cycle times are also described. Advantages of the invention include the ability to use (typically) 30-100 times less adsorbent compared to conventional systems.
Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development
NASA Technical Reports Server (NTRS)
Padilla, Sebastian; Powers, Aaron; Ball, Tyler; Lacomini, Christie; Paul, Heather L.
2009-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2-selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (L CO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas represents a significant source of potential energy for the warming of the adsorbent bed as it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously.
NASA Astrophysics Data System (ADS)
Xu, Hui Fang; Sun, Wen; Han, Xin Feng
2018-06-01
An analytical model of surface potential profiles and transfer characteristics for hetero stacked tunnel field-effect transistors (HS-TFETs) is presented for the first time, where hetero stacked materials are composed of two different bandgaps. The bandgap of the underlying layer is smaller than that of the upper layer. Under different device parameters (upper layer thickness, underlying layer thickness, and hetero stacked materials) and temperature, the validity of the model is demonstrated by the agreement of its results with the simulation results. Moreover, the results show that the HS-TFETs can obtain predominant performance with relatively slow changes of subthreshold swing (SS) over a wide drain current range, steep average subthreshold swing, high on-state current, and large on–off state current ratio.
NASA Astrophysics Data System (ADS)
Shima, Hiroyuki
2012-11-01
The tree-based rope swing is a popular recreational facility, often installed in outdoor areas. Hanging from a rope, users drop from a high platform and then swing at great speed like ‘Tarzan’, finally jumping ahead to land on the ground. The question naturally arises, how far can Tarzan jump using the swing? In this paper, I present an introductory analysis of the mechanics of the Tarzan swing, a large pendulum-like swing with Tarzan himself attached as weight. This enables determination of how much further forward Tarzan can jump using a given swing apparatus. The discussion is based on elementary mechanics and is, therefore, expected to provide rich opportunities for investigations using analytic and numerical methods.
Neuromotor Issues in the Learning and Control of Golf Skill
ERIC Educational Resources Information Center
Knight, Christopher A.
2004-01-01
Theoretical and practical issues related to the neuromotor control of a golf swing are presented in this paper. The typical strategy for golf training consists of high volume repetition with an emphasis on a large variety of isolated swing characteristics. The student is frequently instructed to maintain consistent performance in each swing with…
Thermal evaluation of advanced solar dynamic heat receiver performance
NASA Technical Reports Server (NTRS)
Crane, Roger A.
1989-01-01
The thermal performance of a variety of concepts for thermal energy storage as applied to solar dynamic applications is discussed. It is recognized that designs providing large thermal gradients or large temperature swings during orbit are susceptible to early mechanical failure. Concepts incorporating heat pipe technology may encounter operational limitations over sufficiently large ranges. By reviewing the thermal performance of basic designs, the relative merits of the basic concepts are compared. In addition the effect of thermal enhancement and metal utilization as applied to each design provides a partial characterization of the performance improvements to be achieved by developing these technologies.
Testing, Modeling and System Impact of Metabolic Heat Regenerated Temperature Swing Adsorption
NASA Technical Reports Server (NTRS)
Lacomini, Christine S.; Powers, Aaron; Lewis, Matthew; Linrud, Christopher; Waguespack, Glenn; Conger, Bruce; Paul, Heather L.
2008-01-01
Metabolic heat regenerated temperature swing adsorption (MTSA) technology is being developed for removal and rejection of carbon dioxide (CO2) and heat from a portable life support system (PLSS) to the Martian environment. Previously, hardware was built and tested to demonstrate using heat from simulated, dry ventilation loop gas to affect the temperature swing required to regenerate an adsorbent used for CO2 removal. New testing has been performed using a moist, simulated ventilation loop gas to demonstrate the effects of water condensing and freezing in the heat exchanger during adsorbent regeneration. In addition, thermal models of the adsorbent during regeneration were modified and calibrated with test data to capture the effect of the CO2 heat of desorption. Finally, MTSA impact on PLSS design was evaluated by performing thermal balances assuming a specific PLSS architecture. Results using NASA s Extravehicular Activity System Sizing Analysis Tool (EVAS_SAT), a PLSS system evaluation tool, are presented.
NASA Astrophysics Data System (ADS)
Mallikarjunarao; Ranjan, Rajeev; Pradhan, K. P.; Artola, L.; Sahu, P. K.
2016-09-01
In this paper, a novel N-channel Tunnel Field Effect Transistor (TFET) i.e., Trigate Silicon-ON-Insulator (SOI) N-TFET with high-k spacer is proposed for better Sub-threshold swing (SS) and OFF-state current (IOFF) by keeping in mind the sensitivity towards temperature. The proposed model can achieve a Sub-threshold swing less than 35 mV/decade at various temperatures, which is desirable for designing low power CTFET for digital circuit applications. In N-TFET source doping has a significant effect on the ON-state current (ION) level; therefore more electrons will tunnel from source to channel region. High-k Spacer i.e., HfO2 is used to enhance the device performance and also it avoids overlapping of transistors in an integrated circuits (IC's). We have designed a reliable device by performing the temperature analysis on Transfer characteristics, Drain characteristics and also on various performance metrics like ON-state current (ION), OFF-state current (IOFF), ION/IOFF, Trans-conductance (gm), Trans-conductance Generation Factor (TGF), Sub-threshold Swing (SS) to observe the applications towards harsh temperature environment.
Cycle development and design for CO{sub 2} capture from flue gas by vacuum swing adsorption
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jun Zhang; Paul A. Webley
CO{sub 2} capture and storage is an important component in the development of clean power generation processes. One CO{sub 2} capture technology is gas-phase adsorption, specifically pressure (or vacuum) swing adsorption. The complexity of these processes makes evaluation and assessment of new adsorbents difficult and time-consuming. In this study, we have developed a simple model specifically targeted at CO{sub 2} capture by pressure swing adsorption and validated our model by comparison with data from a fully instrumented pilot-scale pressure swing adsorption process. The model captures non-isothermal effects as well as nonlinear adsorption and nitrogen coadsorption. Using the model and ourmore » apparatus, we have designed and studied a large number of cycles for CO{sub 2} capture. We demonstrate that by careful management of adsorption fronts and assembly of cycles based on understanding of the roles of individual steps, we are able to quickly assess the effect of adsorbents and process parameters on capture performance and identify optimal operating regimes and cycles. We recommend this approach in contrast to exhaustive parametric studies which tend to depend on specifics of the chosen cycle and adsorbent. We show that appropriate combinations of process steps can yield excellent process performance and demonstrate how the pressure drop, and heat loss, etc. affect process performance through their effect on adsorption fronts and profiles. Finally, cyclic temperature profiles along the adsorption column can be readily used to infer concentration profiles - this has proved to be a very useful tool in cyclic function definition. Our research reveals excellent promise for the application of pressure/vacuum swing adsorption technology in the arena of CO{sub 2} capture from flue gases. 20 refs., 6 figs., 2 tabs.« less
Cycle development and design for CO2 capture from flue gas by vacuum swing adsorption.
Zhang, Jun; Webley, Paul A
2008-01-15
CO2 capture and storage is an important component in the development of clean power generation processes. One CO2 capture technology is gas-phase adsorption, specifically pressure (or vacuum) swing adsorption. The complexity of these processes makes evaluation and assessment of new adsorbents difficult and time-consuming. In this study, we have developed a simple model specifically targeted at CO2 capture by pressure swing adsorption and validated our model by comparison with data from a fully instrumented pilot-scale pressure swing adsorption process. The model captures nonisothermal effects as well as nonlinear adsorption and nitrogen coadsorption. Using the model and our apparatus, we have designed and studied a large number of cycles for CO2 capture. We demonstrate that by careful management of adsorption fronts and assembly of cycles based on understanding of the roles of individual steps, we are able to quickly assess the effect of adsorbents and process parameters on capture performance and identify optimal operating regimes and cycles. We recommend this approach in contrast to exhaustive parametric studies which tend to depend on specifics of the chosen cycle and adsorbent. We show that appropriate combinations of process steps can yield excellent process performance and demonstrate how the pressure drop, and heat loss, etc. affect process performance through their effect on adsorption fronts and profiles. Finally, cyclic temperature profiles along the adsorption column can be readily used to infer concentration profiles-this has proved to be a very useful tool in cyclic function definition. Our research reveals excellent promise for the application of pressure/vacuum swing adsorption technology in the arena of CO2 capture from flue gases.
Where do golf driver swings go wrong? Factors influencing driver swing consistency.
Zhang, X; Shan, G
2014-10-01
One of the challenging skills in golfing is the driver swing. There have been a large number of studies characterizing golf swings, yielding insightful instructions on how to swing well. As a result, achieving a sub-18 handicap is no longer the top problem for golfers. Instead, players are now most troubled by a lack of consistency during swing execution. The goal of this study was to determine how to consistently execute good golf swings. Using 3D motion capture and full-body biomechanical modeling, 22 experienced golfers were analysed. For characterizing both successful and failed swings, 19 selected parameters (13 angles, 4 time parameters, and 2 distances) were used. The results showed that 14 parameters are highly sensitive and/or prone to motor control variations. These parameters sensitized five distinct areas of swing to variation: (a) ball positioning, (b) transverse club angle, (c) transition, (d) wrist control, and (e) posture migration between takeaway and impact. Suggestions were provided for how to address these five distinct problem areas. We hope our findings on how to achieve consistency in golf swings will benefit all levels of golf pedagogy and help maintain/develop interests to involve more golf/physical activity for a healthy lifestyle. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Method and apparatus for thermal swing adsorption and thermally-enhanced pressure swing adsorption
Wegeng, Robert S.; Rassat, Scot D.; TeGrotenhuis, Ward E.; Drost, Kevin; Vishwanathan, Vilayanur V.
2004-06-08
The present invention provides compact adsorption systems that are capable of rapid temperature swings and rapid cycling. Novel methods of thermal swing adsorption and thermally-enhanced pressure swing adsorption are also described. In some aspects of the invention, a gas is passed through the adsorbent thus allowing heat exchangers to be very close to all portions of the adsorbent and utilize less space. In another aspect, the adsorption media is selectively heated, thus reducing energy costs. Methods and systems for gas adsorption/desorption having improved energy efficiency with capability of short cycle times are also described. In another aspect, the apparatus or methods utilize heat exchange channels of varying lengths that have volumes controlled to provide equal heat fluxes. Methods of fuel cell startup are also described. Advantages of the invention include the ability to use (typically) 30-100 times less adsorbent compared to conventional systems.
NASA Astrophysics Data System (ADS)
Vu, Quoc An; Fan, Sidi; Hyup Lee, Sang; Joo, Min-Kyu; Jong Yu, Woo; Lee, Young Hee
2018-07-01
While two-dimensional (2D) van der Waals (vdW) layered materials are promising channel materials for wearable electronics and energy-efficient field-effect transistors (FETs), large hysteresis and large subthreshold swing induced by either dangling bonds at gate oxide dielectrics and/or trap molecules in bubbles at vdW interface are a serious drawback, hampering implementation of the 2D-material based FETs in real electronics. Here, we report a monolayer MoS2 FET with near-zero hysteresis reaching 0.15% of the sweeping range of the gate bias, a record-value observed so far in 2D FETs. This was realized by squeezing the MoS2 channel between top h-BN layer and bottom h-BN gate dielectrics and further removing the trap molecules in bubbles at the vdW interfaces via post-annealing. By segregating the bubbles out to the edge of the channel, we also obtain excellent switching characteristics with a minimum subthreshold swing of 63 mV/dec, an average subthreshold slope of 69 mV/dec for a current range of four orders of magnitude at room temperature, and a high on/off current ratio of 108 at a small operating voltage (<1 V). Such a near-zero hysteresis and a near-ideal subthreshold limit originate from the reduced trap density of ~5.2 × 109 cm‑2 eV‑1, a thousand times smaller than previously reported values.
Humidity-swing mechanism for CO2 capture from ambient air.
Yang, Hao; Singh, Manmilan; Schaefer, Jacob
2018-05-10
A humidity-swing polymeric sorbent captures CO2 from ambient air at room temperature simply by changing the humidity level. To date there has been no direct experimental evidence to characterize the chemical mechanism for this process. In this report we describe the use of solid-state NMR to study the humidity-swing CO2 absorption/desorption cycle directly. We find that at low humidity levels CO2 is absorbed as HCO3-. At high humidity levels, HCO3- is replaced by hydrated OH- and the absorbed CO2 is released.
Fixing atmospheric CO2 by environment adaptive sorbent and renewable energy
NASA Astrophysics Data System (ADS)
Wang, T.; Liu, J.; Ge, K.; Fang, M.
2014-12-01
Fixing atmospheric CO2, followed by geologic storage in remote areas is considered an environmentally secure approach to climate mitigation. A moisture swing sorbent was investigated in the laboratory for CO2 capture at a remote area with humid and windy conditions. The energy requirement of moisture swing absorption could be greatly reduced compared to that of traditional high-temperature thermal swing, by assuming that the sorbent can be naturally dried and regenerated at ambient conditions. However, for currently developed moisture swing materials, the CO2 capacity would drop significantly at high relative humidity. The CO2 capture amount can be reduced by the poor thermodynamics and kinetics at high relative humidity or low temperature. Similar challenges also exist for thermal or vacuum swing sorbents. Developing sorbent materials which adapt to specific environments, such as high humidity or low temperature, can ensure sufficient capture capacity on the one hand, and realize better economics on the other hand (Figure 1) .An environment adaptive sorbent should have the abilities of tunable capacity and fast kinetics at extreme conditions, such as high humidity or low temperature. In this presentation, the possibility of tuning CO2 absorption capacity of a polymerized ionic liquid material is discussed. The energy requirement evaluation shows that tuning the CO2 binding energy of sorbent, rather than increasing the temperature or reducing the humidity of air, could be much more economic. By determining whether the absorption process is controlled by physical diffusion controlled or chemical reaction, an effective approach to fast kinetics at extreme conditions is proposed. A shrinking core model for mass transfer kinetics is modified to cope with the relatively poor kinetics of air capture. For the studied sample which has a heterogeneous structure, the kinetic analysis indicates a preference of sorbent particle size optimization, rather than support layer optimization. Chemical reaction kinetics could be enhanced by stronger binding energy or higher temperature. However, the total kinetics can only be significantly improved by chemical reaction enhancement if the physical diffusion is fast enough.
Rapid Swings between Greenhouse and Icehouse Climate States near the Oligocene - Miocene Boundary
NASA Astrophysics Data System (ADS)
Zhang, Y.; Fraass, A.; Ruan, J.; Jin, X.; D'haenens, S.; Gasson, E.; Deconto, R. M.; Pearson, A.; Leckie, R. M.; Liu, C.; Liebrand, D.; Hull, P. M.; Pagani, M.
2017-12-01
The Earth's Cenozoic climate is conventionally portrayed as either being in a greenhouse or an icehouse conditions. Greenhouse climates are characterized by warm temperatures, high CO2 concentrations, low continental ice volume and reduced meridional temperature gradients, whereas icehouse climates are the opposite. The transition between greenhouse and icehouse primarily is achieved through stepwise and unidirectional cooling, ice sheet growth and increases in the meridional temperature gradients. Various feedbacks in the climate system and the global carbon cycle as well as the ice sheet hysteresis effect seem to preclude substantial fluctuations in the meridional temperature gradients, atmospheric CO2 concentrations and the volume of the East Antarctic Ice Sheet (EAIS) on a high frequency (orbital timescales). For example, relative to the Holocene, the last glacial maximum (LGM) is characterized by relatively small pCO2 changes (80-100 parts per million, ppm), similar cooling between the mid- and low-latitudes, and a stable East Antarctica Ice Sheet (EAIS). However, here we present geochemical reconstructions that appear to indicate large and rapid swings of CO2 (>200 ppm) and meridional temperature gradients near the Oligocene - Miocene (O-M) boundary ( 23 Ma). Further, transient waxing and waning of the EAIS during the Mi-1 glaciation is suggested by ice volume calculations based on benthic δ18O data, which are supported by the glaciomarine sequences deposited at the Ross Sea. Our results demonstrate a high sensitivity of surface ocean temperatures and temperature gradients, the global carbon cycle, and the cryosphere to changes in boundary conditions, with implications for our future.
Vitale, Wolfgang A; Casu, Emanuele A; Biswas, Arnab; Rosca, Teodor; Alper, Cem; Krammer, Anna; Luong, Gia V; Zhao, Qing-T; Mantl, Siegfried; Schüler, Andreas; Ionescu, A M
2017-03-23
Steep-slope transistors allow to scale down the supply voltage and the energy per computed bit of information as compared to conventional field-effect transistors (FETs), due to their sub-60 mV/decade subthreshold swing at room temperature. Currently pursued approaches to achieve such a subthermionic subthreshold swing consist in alternative carrier injection mechanisms, like quantum mechanical band-to-band tunneling (BTBT) in Tunnel FETs or abrupt phase-change in metal-insulator transition (MIT) devices. The strengths of the BTBT and MIT have been combined in a hybrid device architecture called phase-change tunnel FET (PC-TFET), in which the abrupt MIT in vanadium dioxide (VO 2 ) lowers the subthreshold swing of strained-silicon nanowire TFETs. In this work, we demonstrate that the principle underlying the low swing in the PC-TFET relates to a sub-unity body factor achieved by an internal differential gate voltage amplification. We study the effect of temperature on the switching ratio and the swing of the PC-TFET, reporting values as low as 4.0 mV/decade at 25 °C, 7.8 mV/decade at 45 °C. We discuss how the unique characteristics of the PC-TFET open new perspectives, beyond FETs and other steep-slope transistors, for low power electronics, analog circuits and neuromorphic computing.
Regenerable Sorbent for CO2 Removal
NASA Technical Reports Server (NTRS)
Alptekin, Gokhan; Jayaraman, Ambal
2013-01-01
A durable, high-capacity regenerable sorbent can remove CO2 from the breathing loop under a Martian atmosphere. The system design allows near-ambient temperature operation, needs only a small temperature swing, and sorbent regeneration takes place at or above 8 torr, eliminating the potential for Martian atmosphere to leak into the regeneration bed and into the breathing loop. The physical adsorbent can be used in a metabolic, heat-driven TSA system to remove CO2 from the breathing loop of the astronaut and reject it to the Martian atmosphere. Two (or more) alternating sorbent beds continuously scrub and reject CO2 from the spacesuit ventilation loop. The sorbent beds are cycled, alternately absorbing CO2 from the vent loop and rejecting the adsorbed material into the environment at a high CO2 partial pressure (above 8 torr). The system does not need to run the adsorber at cryogenic temperatures, and uses a much smaller temperature swing. The sorbent removes CO2 via a weak chemical interaction. The interaction is strong enough to enable CO2 adsorption even at 3 to 7.6 torr. However, because the interaction between the surface adsorption sites and the CO2 is relatively weak, the heat input needed to regenerate the sorbent is much lower than that for chemical absorbents. The sorbent developed in this project could potentially find use in a large commercial market in the removal of CO2 emissions from coal-fired power plants, if regulations are put in place to curb carbon emissions from power plants.
NASA Astrophysics Data System (ADS)
Tsai, Ming-Yen; Chang, Ting-Chang; Chu, Ann-Kuo; Hsieh, Tien-Yu; Chen, Te-Chih; Lin, Kun-Yao; Tsai, Wu-Wei; Chiang, Wen-Jen; Yan, Jing-Yi
2013-07-01
This letter investigates the effect of temperature on hot-carrier stress-induced degradation behavior in InGaZnO thin film transistors. After hot-carrier stress at 25 °C, serious on-current and subthreshold swing degradations are observed due to trap state generation near the drain side. For identical stress performed at elevated temperatures, current degradation in the I-V transfer curve under reverse mode is gradually suppressed and the anomalous hump in the gate-to-drain capacitance-voltage curve becomes more severe. These suppressed degradations and the more severe hump can be both attributed to hole-trapping near the drain side due to high drain bias at high temperature.
Rapid Temperature Swing Adsorption using Polymeric/Supported Amine Hollow Fibers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chance, Ronald; Chen, Grace; Dai, Ying
This project is a bench-scale, post-combustion capture project carried out at Georgia Tech (GT) with support and collaboration with GE, Algenol Biofuels, Southern Company and subcontract to Trimeric Corporation. The focus of the project is to develop a process based on composite amine-functionalized oxide / polymer hollow fibers for use as contactors in a rapid temperature swing adsorption post-combustion carbon dioxide capture process. The hollow fiber morphology allows coupling of efficient heat transfer with effective gas contacting, potentially giving lower parasitic loads on the power plant compared to traditional contacting strategies using solid sorbents.
An adsorption of carbon dioxide on activated carbon controlled by temperature swing adsorption
NASA Astrophysics Data System (ADS)
Tomas, Korinek; Karel, Frana
2017-09-01
This work deals with a method of capturing carbon dioxide (CO2) in indoor air. Temperature Swing Adsorption (TSA) on solid adsorbent was chosen for CO2 capture. Commercial activated carbon (AC) in form of extruded pellets was used as a solid adsorbent. There was constructed a simple device to testing effectiveness of CO2 capture in a fixed bed with AC. The TSA cycle was also simulated using the open-source software OpenFOAM. There was a good agreement between results obtained from numerical simulations and experimental data for adsorption process.
NASA Technical Reports Server (NTRS)
Knox, J. C.; Mulloth, Lila; Frederick, Kenneth; Affleck, Dave
2003-01-01
Accumulation and subsequent compression of carbon dioxide that is removed from space cabin are two important processes involved in a closed-loop air revitalization scheme of the International Space Station (ISS). The carbon dioxide removal assembly (CDRA) of ISS currently operates in an open loop mode without a compressor. This paper describes the integrated test results of a flight-like CDRA and a temperature-swing adsorption compressor (TSAC) for carbon dioxide removal and compression. The paper provides details of the TSAC operation at various CO2 loadings and corresponding performance of CDRA.
Arm swing magnitude and asymmetry during gait in the early stages of Parkinson's disease.
Lewek, Michael D; Poole, Roxanne; Johnson, Julia; Halawa, Omar; Huang, Xuemei
2010-02-01
The later stages of Parkinson's disease (PD) are characterized by altered gait patterns. Although decreased arm swing during gait is the most frequently reported motor dysfunction in individuals with PD, quantitative descriptions of gait in early PD have largely ignored upper extremity movements. This study was designed to perform a quantitative analysis of arm swing magnitude and asymmetry that might be useful in the assessment of early PD. Twelve individuals with early PD (in "off" state) and eight controls underwent gait analysis using an optically-based motion capture system. Participants were instructed to walk at normal and fast velocities, and then on heels (to minimize push-off). Arm swing was measured as the excursion of the wrist with respect to the pelvis. Arm swing magnitude for each arm, and inter-arm asymmetry, were compared between groups. Both groups had comparable gait velocities (p = 0.61), and there was no significant difference between the groups in the magnitude of arm swing in all walking conditions for the arm that swung more (p = 0.907) or less (p = 0.080). Strikingly, the PD group showed significantly greater arm swing asymmetry (asymmetry angle: 13.9 + or - 7.9%) compared to the control group (asymmetry angle: 5.1 + or - 4.0%; p = 0.003). Unlike arm swing magnitude, arm swing asymmetry unequivocally differs between people with early PD and controls. Such quantitative evaluation of arm swing, especially its asymmetry, may have utility for early and differential diagnosis, and for tracking disease progression in patients with later PD. Copyright 2009 Elsevier B.V. All rights reserved.
Arm Swing Magnitude and Asymmetry During Gait in the Early Stages of Parkinson's Disease
Lewek, Michael D.; Poole, Roxanne; Johnson, Julia; Halawa, Omar; Huang, Xuemei
2009-01-01
The later stages of Parkinson's disease (PD) are characterized by altered gait patterns. Although decreased arm swing during gait is the most frequently reported motor dysfunction in individuals with PD, quantitative descriptions of gait in early PD have largely ignored upper extremity movements. This study was designed to perform a quantitative analysis of arm swing magnitude and asymmetry that might be useful in the assessment of early PD. Twelve individuals with early PD (in “off” state) and eight controls underwent gait analysis using an optically-based motion capture system. Participants were instructed to walk at normal and fast velocities, and then on heels (to minimize push-off). Arm swing was measured as the excursion of the wrist with respect to the pelvis. Arm swing magnitude for each arm, and inter-arm asymmetry, were compared between groups. Both groups had comparable gait velocities (p=0.61), and there was no significant difference between the groups in the magnitude of arm swing in all walking conditions for the arm that swung more (p=0.907) or less (p=0.080). Strikingly, the PD group showed significantly greater arm swing asymmetry (asymmetry angle: 13.9±7.9%) compared to the control group (asymmetry angle: 5.1±4.0%; p=0.003). Unlike arm swing magnitude, arm swing asymmetry unequivocally differs between people with early PD and controls. Such quantitative evaluation of arm swing, especially its asymmetry, may have utility for early and differential diagnosis, and for tracking disease progression in patients with later PD. PMID:19945285
The 23 to 300 C demagnetization resistance of samarium-cobalt permanent magnets
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Overton, Eric
1991-01-01
The influence of temperature on knee point and squareness of the M-H demagnetization characteristic of permanent magnets is important information for the full utilization of the capabilities of samarium-cobalt magnets at high temperature in demagnetization resistent permanent magnet devices. Composite plots of the knee field and the demagnetizing field required to produce a given magnetic induction swing below remanence were obtained for several commercial Sm2Co17 type magnet samples in the temperature range of 23 to 300 C. Using the knee point to define the limits of operation safe against irreversible demagnetization, such plots are shown to provide an effective overview of the useable regions in the space of temperature-induction swing parameters. The observed second quadrant M-H characteristic squareness is shown, by two measures, to increase gradually with temperature, reaching a peak in the interval 200 to 300 C.
Effect of human behavior on economizer efficacy and thermal comfort in southern California
NASA Astrophysics Data System (ADS)
Lanning, TIghe Glennon
California has set a zero net-energy conservation goal for the residential sector that is to be achieved by 2020 (California Energy Commission 2011). To reduce energy consumption in the building sector, modern buildings should fundamentally incorporate sustainable performance standards, involving renewable systems, climate-specific strategies, and consideration of a variety of users. Building occupants must operate in concert with the buildings they inhabit in order to maximize the potential of the building, its systems, and their own comfort. In climates with significant diurnal temperature swings, environmental controls designed to capitalize on this should be considered to reduce cooling-related loads. One specific strategy is the air-side economizer, which uses daily outdoor temperature swings to reduce indoor temperature swings. Traditionally a similar effect could be achieved by using thermal mass to buffer indoor temperature swings through thermal lag. Economizers reduce the amount of thermal mass typically required by naturally ventilated buildings. Fans are used to force cool nighttime air deep into the building, allowing lower mass buildings to take advantage of nighttime cooling. Economizers connect to a thermostat, and when the outdoor temperature dips below a programmed set-point the economizer draws cool air from outside, flushing out the warmed interior air. This type of system can be simulated with reasonable accuracy by energy modeling programs; however, because the system is occupant-driven (as opposed to a truly passive mass-driven system) any unpredictable occupant behavior can reduce its effectiveness and create misleading simulation results. This unpredictably has helped prevent the spread of economizers in the residential market. This study investigated to what extent human behavior affected the performance of economizer-based HVAC systems, based on physical observations, environmental data collections, and energy simulations of a residential building in Los Angeles, California. Tangible measures for alleviating problems, such as user-friendly interface design and the incorporation of human behavior into energy models are recommended based on these observations.
Vibro-Impact Type Triboelectric Energy Harvester for Large Amplitude and Wideband Applications
NASA Astrophysics Data System (ADS)
Chen, J. M.; Bu, L.; Xu, W. Y.; Xu, B. J.; Song, L.
2015-12-01
This paper reports the design, fabrication and testing of a novel vibro-impact type triboelectric energy harvester. The dynamics of vibro-impact converts external vibration to large contact force for triboelectric power generation. Strong nonlinearities are measured for this vibro-impact system, and wideband frequency response under diverse structural parameters are analyzed. The proposed device is applied in two large amplitude scenarios, and generates maximal peak-to-peak voltage of 18V in foot swinging condition @2Hz 30cm, and maximal peak-to-peak voltage of 45 V in arm swinging condition during running @5Hz 40cm.
Blum, Yvonne; Vejdani, Hamid R; Birn-Jeffery, Aleksandra V; Hubicki, Christian M; Hurst, Jonathan W; Daley, Monica A
2014-01-01
To achieve robust and stable legged locomotion in uneven terrain, animals must effectively coordinate limb swing and stance phases, which involve distinct yet coupled dynamics. Recent theoretical studies have highlighted the critical influence of swing-leg trajectory on stability, disturbance rejection, leg loading and economy of walking and running. Yet, simulations suggest that not all these factors can be simultaneously optimized. A potential trade-off arises between the optimal swing-leg trajectory for disturbance rejection (to maintain steady gait) versus regulation of leg loading (for injury avoidance and economy). Here we investigate how running guinea fowl manage this potential trade-off by comparing experimental data to predictions of hypothesis-based simulations of running over a terrain drop perturbation. We use a simple model to predict swing-leg trajectory and running dynamics. In simulations, we generate optimized swing-leg trajectories based upon specific hypotheses for task-level control priorities. We optimized swing trajectories to achieve i) constant peak force, ii) constant axial impulse, or iii) perfect disturbance rejection (steady gait) in the stance following a terrain drop. We compare simulation predictions to experimental data on guinea fowl running over a visible step down. Swing and stance dynamics of running guinea fowl closely match simulations optimized to regulate leg loading (priorities i and ii), and do not match the simulations optimized for disturbance rejection (priority iii). The simulations reinforce previous findings that swing-leg trajectory targeting disturbance rejection demands large increases in stance leg force following a terrain drop. Guinea fowl negotiate a downward step using unsteady dynamics with forward acceleration, and recover to steady gait in subsequent steps. Our results suggest that guinea fowl use swing-leg trajectory consistent with priority for load regulation, and not for steadiness of gait. Swing-leg trajectory optimized for load regulation may facilitate economy and injury avoidance in uneven terrain.
Blum, Yvonne; Vejdani, Hamid R.; Birn-Jeffery, Aleksandra V.; Hubicki, Christian M.; Hurst, Jonathan W.; Daley, Monica A.
2014-01-01
To achieve robust and stable legged locomotion in uneven terrain, animals must effectively coordinate limb swing and stance phases, which involve distinct yet coupled dynamics. Recent theoretical studies have highlighted the critical influence of swing-leg trajectory on stability, disturbance rejection, leg loading and economy of walking and running. Yet, simulations suggest that not all these factors can be simultaneously optimized. A potential trade-off arises between the optimal swing-leg trajectory for disturbance rejection (to maintain steady gait) versus regulation of leg loading (for injury avoidance and economy). Here we investigate how running guinea fowl manage this potential trade-off by comparing experimental data to predictions of hypothesis-based simulations of running over a terrain drop perturbation. We use a simple model to predict swing-leg trajectory and running dynamics. In simulations, we generate optimized swing-leg trajectories based upon specific hypotheses for task-level control priorities. We optimized swing trajectories to achieve i) constant peak force, ii) constant axial impulse, or iii) perfect disturbance rejection (steady gait) in the stance following a terrain drop. We compare simulation predictions to experimental data on guinea fowl running over a visible step down. Swing and stance dynamics of running guinea fowl closely match simulations optimized to regulate leg loading (priorities i and ii), and do not match the simulations optimized for disturbance rejection (priority iii). The simulations reinforce previous findings that swing-leg trajectory targeting disturbance rejection demands large increases in stance leg force following a terrain drop. Guinea fowl negotiate a downward step using unsteady dynamics with forward acceleration, and recover to steady gait in subsequent steps. Our results suggest that guinea fowl use swing-leg trajectory consistent with priority for load regulation, and not for steadiness of gait. Swing-leg trajectory optimized for load regulation may facilitate economy and injury avoidance in uneven terrain. PMID:24979750
Lunar and Martian environmental interactions with nuclear power system radiators
NASA Technical Reports Server (NTRS)
Perez-Davis, Marla E.; Gaier, James R.; Katzan, Cynthia M.
1992-01-01
Future NASA space missions include a permanent manned presence on the moon and an expedition to the planet Mars. Such steps will require careful consideration of environmental interactions in the selection and design of required power systems. Several environmental constituents may be hazardous to performance integrity. Potential threats common to both the moon and Mars are low ambient temperatures, wide daily temperature swings, solar flux, and large quantities of dust. The surface of Mars provides the additional challenges of dust storms, winds, and a carbon dioxide atmosphere. In this review, the anticipated environmental interactions with surface power system radiators are described, as well as the impacts of these interactions on radiator durability, which were identified at NASA Lewis Research Center.
Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption
NASA Technical Reports Server (NTRS)
Padilla, Sebastian A.; Bower, Chad E.; Iacomini, Christie S.; Paul, Heather L.
2012-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA Subassembly (MTSAS) was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort was testing in a simulated lunar environment. This environment was simulated in Paragon's EHF vacuum chamber. The objective of the testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. Lunar environment testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 Nomenclature loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This exceeded any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.
Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption Technology
NASA Technical Reports Server (NTRS)
Padilla, Sebastian A.; Bower, Chad; Iacomini, Christie S.; Paul, H.
2011-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA subassembly was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort is operations and testing in a simulated lunar environment. This environment was simulated in Paragon s EHF vacuum chamber. The objective of this testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. The lunar testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This had not been achieved in any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.
NASA Technical Reports Server (NTRS)
Mulloth, Lila M.; Affleck, Dave L.; Rosen, Micha; LeVan, M. Douglas; Wang, Yuan; Cavalcante, Celio L.
2004-01-01
The air revitalization system of the International Space Station (ISS) operates in an open loop mode and relies on the resupply of oxygen and other consumables from earth for the life support of astronauts. A compressor is required for delivering the carbon dioxide from a removal assembly to a reduction unit to recover oxygen and thereby closing the air-loop. We have a developed a temperature-swing adsorption compressor (TSAC) for performing these tasks that is energy efficient, quiet, and has no rapidly moving parts. This paper discusses the mechanical design and the results of thermal model validation tests of a TSAC that uses air as the cooling medium.
Design and Development of an air-cooled Temperature-Swing Adsorption Compressor for Carbon Dioxide
NASA Technical Reports Server (NTRS)
Mulloth, Lila M.
2003-01-01
The air revitalization system of the International Space Station (ISS) operates in an open loop mode and relies on the resupply of oxygen and other consumables from earth for the life support of astronauts. A compressor is required for delivering the carbon dioxide from a removal assembly to a reduction unit to recover oxygen and thereby closing the air-loop. We have a developed a temperature-swing adsorption compressor (TSAC) for performing these tasks that is energy efficient, quiet, and has no wearing parts. This paper discusses the design features of a TSAC hardware that uses air as the cooling medium and has Space Station application.
Temperature Swing Adsorption Compressor Development
NASA Technical Reports Server (NTRS)
Finn, John E.; Mulloth, Lila M.; Affleck, Dave L.
2001-01-01
Closing the oxygen loop in an air revitalization system based on four-bed molecular sieve and Sabatier reactor technology requires a vacuum pump-compressor that can take the low-pressure CO, from the 4BMS and compress and store for use by a Sabatier reactor. NASA Ames Research Center proposed a solid-state temperature-swing adsorption (TSA) compressor that appears to meet performance requirements, be quiet and reliable, and consume less power than a comparable mechanical compressor/accumulator combination. Under this task, TSA compressor technology is being advanced through development of a complete prototype system. A liquid-cooled TSA compressor has been partially tested, and the rest of the system is being fabricated. An air-cooled TSA compressor is also being designed.
The Neuro-Mechanical Processes That Underlie Goal-Directed Medio-Lateral APA during Gait Initiation.
Honeine, Jean-Louis; Schieppati, Marco; Crisafulli, Oscar; Do, Manh-Cuong
2016-01-01
Gait initiation (GI) involves passing from bipedal to unipedal stance. It requires a rapid movement of the center of foot pressure (CoP) towards the future swing foot and of the center of mass (CoM) in the direction of the stance foot prior to the incoming step. This anticipatory postural adjustment (APA) allows disengaging the swing leg from the ground and establishing favorable conditions for stepping. This study aimed to describe the neuro-mechanical process that underlies the goal-directed medio-lateral (ML) APA. We hypothesized that controlled knee flexion of the stance leg contributes to the initial ML displacement of the CoP and to the calibration of the first step. Fourteen subjects initiated gait starting from three different initial stance widths of 15 cm (Small), 30 cm (Medium), and 45 cm (Large). Optoelectronic, force platform and electromyogram (EMG) measurements were performed. During APA, soleus activity diminished bilaterally, while tibialis anterior (TA) activity increased, more so in the stance leg than in the swing leg, and to a larger extent with increasing initial stance width. Knee flexion of the stance leg was observed during APA and correlated with the ML CoP displacement towards the swing leg. ML CoP and CoM displacements during APA increased with increasing stance width. The activity of stance-leg TA was correlated with the degree of knee flexion. Swing-leg tensor fasciae latae (TFL) was also active during APA. Across subjects, when stance-leg tibialis activity was low, TFL activity was large and vice versa. The modulation of the ML CoP position during APA allowed the gravity-driven torque to place the CoM just lateral to the stance foot during step execution. Accordingly, the gravity-driven torque, the ML CoM velocity during step execution, and the step width at foot contact (FC) were lower in the Small and greater in the Large condition. Consequently, the position of the stepping foot at FC remained close to the sagittal plane in all three conditions. Conclusively, coordinated activation of hip abductors and ankle dorsiflexors during APA displaces the CoP towards the swing leg, and sets the contact position for the swing foot.
The Neuro-Mechanical Processes That Underlie Goal-Directed Medio-Lateral APA during Gait Initiation
Honeine, Jean-Louis; Schieppati, Marco; Crisafulli, Oscar; Do, Manh-Cuong
2016-01-01
Gait initiation (GI) involves passing from bipedal to unipedal stance. It requires a rapid movement of the center of foot pressure (CoP) towards the future swing foot and of the center of mass (CoM) in the direction of the stance foot prior to the incoming step. This anticipatory postural adjustment (APA) allows disengaging the swing leg from the ground and establishing favorable conditions for stepping. This study aimed to describe the neuro-mechanical process that underlies the goal-directed medio-lateral (ML) APA. We hypothesized that controlled knee flexion of the stance leg contributes to the initial ML displacement of the CoP and to the calibration of the first step. Fourteen subjects initiated gait starting from three different initial stance widths of 15 cm (Small), 30 cm (Medium), and 45 cm (Large). Optoelectronic, force platform and electromyogram (EMG) measurements were performed. During APA, soleus activity diminished bilaterally, while tibialis anterior (TA) activity increased, more so in the stance leg than in the swing leg, and to a larger extent with increasing initial stance width. Knee flexion of the stance leg was observed during APA and correlated with the ML CoP displacement towards the swing leg. ML CoP and CoM displacements during APA increased with increasing stance width. The activity of stance-leg TA was correlated with the degree of knee flexion. Swing-leg tensor fasciae latae (TFL) was also active during APA. Across subjects, when stance-leg tibialis activity was low, TFL activity was large and vice versa. The modulation of the ML CoP position during APA allowed the gravity-driven torque to place the CoM just lateral to the stance foot during step execution. Accordingly, the gravity-driven torque, the ML CoM velocity during step execution, and the step width at foot contact (FC) were lower in the Small and greater in the Large condition. Consequently, the position of the stepping foot at FC remained close to the sagittal plane in all three conditions. Conclusively, coordinated activation of hip abductors and ankle dorsiflexors during APA displaces the CoP towards the swing leg, and sets the contact position for the swing foot. PMID:27642280
Jazz Style and Articulation: How to Get Your Band or Choir to Swing
ERIC Educational Resources Information Center
Tolson, Jerry
2012-01-01
The interpretation of jazz style is crucial to the element of swing in any jazz ensemble performance. Today, many charts for both large and small instrumental and vocal jazz ensembles are well marked with articulations and expression markings. However, in some cases, there is nothing to guide the musician. This article addresses some common jazz…
Efficient generation of H2 by splitting water with an isothermal redox cycle.
Muhich, Christopher L; Evanko, Brian W; Weston, Kayla C; Lichty, Paul; Liang, Xinhua; Martinek, Janna; Musgrave, Charles B; Weimer, Alan W
2013-08-02
Solar thermal water-splitting (STWS) cycles have long been recognized as a desirable means of generating hydrogen gas (H2) from water and sunlight. Two-step, metal oxide-based STWS cycles generate H2 by sequential high-temperature reduction and water reoxidation of a metal oxide. The temperature swings between reduction and oxidation steps long thought necessary for STWS have stifled STWS's overall efficiency because of thermal and time losses that occur during the frequent heating and cooling of the metal oxide. We show that these temperature swings are unnecessary and that isothermal water splitting (ITWS) at 1350°C using the "hercynite cycle" exhibits H2 production capacity >3 and >12 times that of hercynite and ceria, respectively, per mass of active material when reduced at 1350°C and reoxidized at 1000°C.
NASA Technical Reports Server (NTRS)
Padilla, Sebastian A.; Powers, Aaron; Iacomini, Christie S.; Paul, Heather L.
2011-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. The core of the MTSA technology is a sorbent bed that removes CO2 from the PLSS ventilation loop gas via a temperature swing. A Condensing Ice Heat eXchanger (CIHX) is used to warm the sorbent while also removing water from the ventilation loop gas. A Sublimation Heat eXchanger (SHX) is used to cool the sorbent. Research was performed to explore an MTSA designed for both lunar and Martian operations. Previously each the sorbent bed, CIHX, and SHX had been built and tested individually on a scale relevant to PLSS operations, but they had not been done so as an integrated subassembly. Design and analysis of an integrated subassembly was performed based on this prior experience and an updated transient system model. Focus was on optimizing the design for Martian operations, but the design can also be used in lunar operations. An Engineering Development Unit (EDU) of an integrated MTSA subassembly was assembled based on the design. Its fabrication is discussed. Some details on the differences between the as-assembled EDU to the future flight unit are considered.
NASA Technical Reports Server (NTRS)
Padilla, Sebastian A.; Powers, Aaron; Iacomini, Christie S.; Bower, Chad E.; Paul, Heather L.
2012-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. The core of the MTSA technology is a sorbent bed that removes CO2 from the PLSS ventilation loop gas via a temperature swing. A Condensing Icing Heat eXchanger (CIHX) is used to warm the sorbent while also removing water from the ventilation loop gas. A Sublimation Heat eXchanger (SHX) is used to cool the sorbent. Research was performed to explore an MTSA designed for both lunar and Martian operations. Previously the sorbent bed, CIHX, and SHX had been built and tested individually on a scale relevant to PLSS operations, but they had not been done so as an integrated subassembly. Design and analysis of an integrated subassembly was performed based on this prior experience and an updated transient system model. Focus was on optimizing the design for Martian operations, but the design can also be used in lunar operations. An Engineering Development Unit (EDU) of an integrated MTSA subassembly was assembled based on the design. Its fabrication is discussed. Some details on the differences between the as-assembled EDU and the future flight unit are considered.
Liu, Xinke; Ang, Kah-Wee; Yu, Wenjie; He, Jiazhu; Feng, Xuewei; Liu, Qiang; Jiang, He; Dan Tang; Wen, Jiao; Lu, Youming; Liu, Wenjun; Cao, Peijiang; Han, Shun; Wu, Jing; Liu, Wenjun; Wang, Xi; Zhu, Deliang; He, Zhubing
2016-04-22
Black phosphorus (BP) has emerged as a promising two-dimensional (2D) material for next generation transistor applications due to its superior carrier transport properties. Among other issues, achieving reduced subthreshold swing and enhanced hole mobility simultaneously remains a challenge which requires careful optimization of the BP/gate oxide interface. Here, we report the realization of high performance BP transistors integrated with HfO2 high-k gate dielectric using a low temperature CMOS process. The fabricated devices were shown to demonstrate a near ideal subthreshold swing (SS) of ~69 mV/dec and a room temperature hole mobility of exceeding >400 cm(2)/Vs. These figure-of-merits are benchmarked to be the best-of-its-kind, which outperform previously reported BP transistors realized on traditional SiO2 gate dielectric. X-ray photoelectron spectroscopy (XPS) analysis further reveals the evidence of a more chemically stable BP when formed on HfO2 high-k as opposed to SiO2, which gives rise to a better interface quality that accounts for the SS and hole mobility improvement. These results unveil the potential of black phosphorus as an emerging channel material for future nanoelectronic device applications.
System and process for polarity swing assisted regeneration of gas selective capture liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heldebrant, David J.; Tegrotenhuis, Ward E.; Freeman, Charles J.
A polarity swing-assisted regeneration (PSAR) process is disclosed for improving the efficiency of releasing gases chemically bound to switchable ionic liquids. Regeneration of the SWIL involves addition of a quantity of non-polar organic compound as an anti-solvent to destabilize the SWIL, which aids in release of the chemically bound gas. The PSAR decreases gas loading of a SWIL at a given temperature and increases the rate of gas release compared to heating in the absence of anti-solvent.
Possible Economies in Air-Conditioning by Accepting Temperature Swings.
ERIC Educational Resources Information Center
Loudon, A. G.; Petherbridge, P.
Public building air conditioning systems, which use constant and varying heat and cooling loads, are compared and investigated. Experiments indicated that constant temperature controls based on outside air temperature alone were inefficient. Ventilating a building with outside air and the methods of doing so are cited as being the most economical…
NECAP 4.1: NASA's Energy-Cost Analysis Program input manual
NASA Technical Reports Server (NTRS)
Jensen, R. N.
1982-01-01
The computer program NECAP (NASA's Energy Cost Analysis Program) is described. The program is a versatile building design and energy analysis tool which has embodied within it state of the art techniques for performing thermal load calculations and energy use predictions. With the program, comparisons of building designs and operational alternatives for new or existing buildings can be made. The major feature of the program is the response factor technique for calculating the heat transfer through the building surfaces which accounts for the building's mass. The program expands the response factor technique into a space response factor to account for internal building temperature swings; this is extremely important in determining true building loads and energy consumption when internal temperatures are allowed to swing.
Influence of maturation on instep kick biomechanics in female soccer athletes.
Lyle, Mark A; Sigward, Susan M; Tsai, Liang-Ching; Pollard, Christine D; Powers, Christopher M
2011-10-01
The purpose of this study was to compare kicking biomechanics between young female soccer players at two different stages of physical maturation and to identify biomechanical predictors of peak foot velocity. Swing and stance limb kinematics and kinetics were recorded from 20 female soccer players (10 prepubertal, 10 postpubertal) while kicking a soccer ball using an angled two-step approach. Peak foot velocity as well as hip and knee kinematics and kinetics were compared between groups using independent-samples t-tests. Pearson correlation coefficients and stepwise multiple regression were used to identify predictors of peak foot velocity. Peak foot velocity and the peak swing limb net hip flexor moment was significantly greater in the postpubertal group when compared with the prepubertal group (13.4 vs 11.6 m·s(-1), P = 0.003; 1.22 vs 1.07 N·m·kg(-1)·m(-1), P = 0.03). Peak stance limb hip and knee extensor moments were not different between groups. Although the peak swing limb hip and knee flexion angles were similar between groups, the postpubertal group demonstrated significantly less peak stance limb hip and knee flexion angles when compared with the prepubertal group (P < 0.001 and P = 0.045). Using a linear regression model, swing limb peak hip flexor moment and peak swing limb hip extension range of motion combined to explain 65% of the variance in peak foot velocity. Despite a difference in stance limb kinematics, similar swing limb kinematics between groups indicates that the prepubertal female athletes kicked with a mature swing limb kick pattern. The ability to generate a large hip flexor moment of the swing limb seems to be an important factor for improving kicking performance in young female soccer players.
Reactive extraction of lactic acid with trioctylamine/methylene chloride/n-hexane
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, D.H.; Hong, W.H.
The trioctylamine (TOA)/methylene chloride (MC)/n-hexane system was used as the extraction agent for the extraction of lactic acid. Curves of equilibrium and hydration were obtained at various temperatures and concentrations of TOA. A modified mass action model was proposed to interpret the equilibrium and the hydration curves. The reaction mechanism and the corresponding parameters which best represent the equilibrium data were estimated, and the concentration of water in the organic phase was predicted by inserting the parameters into the simple mathematical equation of the modified model. The concentration of MC and the change of temperature were important factors for themore » extraction and the stripping process. The stripping was performed by a simple distillation which was a combination of temperature-swing regeneration and diluent-swing regeneration. The type of inactive diluent has no influence on the stripping. The stripping efficiencies were about 70%.« less
NASA Astrophysics Data System (ADS)
Palodkar, Avinash V.; Anupam, Kumar; Roy, Zunipa; Saha, B. B.; Halder, G. N.
2017-10-01
Adsorption characteristics of nitrogen onto granular activated carbon for the wide range of temperature (303-323 K) and pressure (0.2027-2.0265 MPa) have been reported for a single bed pressure swing adsorption refrigeration system. The experimental data were fitted to Langmuir, Dubinin-Astakhov and Dubinin-Radushkevich (D-R) isotherms. The Langmuir and D-R isotherm models were found appropriate in correlating experimental adsorption data with an average relative error of ±2.0541% and ±0.6659% respectively. The isosteric heat of adsorption data were estimated as a function of surface coverage of nitrogen and temperature using D-R isotherm. The heat of adsorption was observed to decrease from 12.65 to 6.98 kJ.mol-1 with an increase in surface concentration at 303 K and it followed the same pattern for other temperatures. It was found that an increase in temperature enhances the magnitude of the heat of adsorption.
A double pendulum swing experiment: In search of a better bat
NASA Astrophysics Data System (ADS)
Cross, Rod
2005-04-01
Experimental results on the large-amplitude motion of a double pendulum are presented, with emphasis on the first half cycle. The initial part of the swing is reproducible and is of interest in modeling various human movement activities such as running, throwing, kicking, and the swing of a bat or racquet. Beyond this time, the motion is chaotic. The forces and torques acting on each pendulum segment are analyzed to explain its motion. The results show how a "perfect" bat could be designed where all the kinetic energy from the player's arms is transferred to the ball and none is retained in the arms or the bat after the impact.
Grip pressure distributions and associated variability in golf: a two-club comparison.
Langlais, Sean M; Broker, Jeffrey P
2014-06-01
Teaching and playing professionals offer multiple theories concerning the manner in which forces should be applied to the handle of the club during the golf swing. This study extends recent research concerning grip pressures and forces in golf, with the purpose of exploring the similarities and differences between force profiles for a 7-iron and driver swung by proficient golfers. A secondary purpose was to further analyze the way that golfers use grip forces to manipulate the club. Grip forces were measured on eight low handicap golfers (USGA indexes 0 to 7) swinging their own 7-irons and drivers. In total, lead-hand and trail-hand grip forces were isolated as well as anatomically specific forces within the hands. Force profile variability across multiple swings for each golfer and between golfers characterized consistencies and important differences. Correlations between 7-iron and driver force profiles characterized force 'signatures.' The data highlight large fluctuations in grip forces during the swing. Marked differences between participants were observed, involving force magnitudes and phasing. Dominant forces arose primarily from the lead hand, specifically the last three fingers. Force profiles were highly repeatable across swings for a golfer (standard deviations < 7% of total force) and force profile correlations between 7-iron and driver for a golfer were remarkably high (r2 = 0.86). Notably, within swing force variability was greatest during club acceleration, but dramatically decreased at impact.
Environmentally induced acoustic emission from reinforced concrete
NASA Astrophysics Data System (ADS)
Pollock, Adrian A.; Gonzalez-Nunez, Miguel; Shokri, Tala
2011-04-01
A system is being developed to monitor in-service deterioration of reinforced concrete (RC) in highway bridges. The system includes the monitoring of acoustic emission (AE). To develop a preliminary understanding of AE source mechanisms and their causes while also getting closer to the challenges of separating relevant AE from noise, a 6ft long RC test article was monitored in the outdoors environment of a New Jersey summer. There were indications of daily swings in the AE rate, coinciding with the daily swings in temperature. However this correlation was not consistent or reproducible. As the monitoring was extended into the winter and the test site was buried in snow, the AE rate dropped drastically. It was concluded that temperature changes were instrumental in stimulating AE from this damaged concrete. Implications for the formulation of AE evaluation criteria are discussed. Also, the summer swings provoked consideration of the underlying stress field, the fractal nature of the heterogeneous material and the stochastic AE phenomenon. An analysis of calm time distributions yielded results similar to those found by Abe and Suzuki for earthquake time distributions. Analysis of this kind may help to differentiate relevant AE from some kinds of noise.
NASA Astrophysics Data System (ADS)
Yun, Seung Jae; Lee, Yong Woo; Son, Se Wan; Byun, Chang Woo; Reddy, A. Mallikarjuna; Joo, Seung Ki
2012-08-01
A planarized thick copper (Cu) gate low temperature polycrystalline silicon (LTPS) thin film transistors (TFTs) is fabricated for ultra-large active-matrix organic light-emitting diode (AMOLED) displays. We introduce a damascene and chemical mechanical polishing process to embed a planarized Cu gate of 500 nm thickness into a trench and Si3N4/SiO2 multilayer gate insulator, to prevent the Cu gate from diffusing into the silicon (Si) layer at 550°C, and metal-induced lateral crystallization (MILC) technology to crystallize the amorphous Si layer. A poly-Si TFT with planarized thick Cu gate exhibits a field effect mobility of 5 cm2/Vs and a threshold voltage of -9 V, and a subthreshold swing (S) of 1.4 V/dec.
True Shear Parallel Plate Viscometer
NASA Technical Reports Server (NTRS)
Ethridge, Edwin; Kaukler, William
2010-01-01
This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.
The Effects of Increased Body Temperature on Motor Control during Golf Putting
Mathers, John F.; Grealy, Madeleine A.
2016-01-01
This study investigated the effect of increased core temperature on the performance outcome and movement kinematics of elite golfers during a golf putting task. The study aimed to examine individual differences in the extent to which increased temperature influenced the rate of putting success, whether increased temperature speeded up the timing of the putting downswing and whether elite golfers changed their movement kinematics during times of thermal stress. Six participants performed 20 putts to each of four putt distances (1, 2, 3, and 4 m) under normal temperature conditions and when core body temperature was increased. There was no significant difference in the number of successful putts between the two temperature conditions, but there was an increase in putterhead velocity at ball impact on successful putts to distances of 1 and 4 m when temperature was elevated. This reflected an increase in swing amplitude rather than a reduction in swing duration as hypothesized. There were individual differences in the motor control response to thermal stress as three of the golfers changed the kinematic parameters used to scale their putting movements to achieve putts of different distances at elevated temperatures. Theoretical implications for these findings and the practical implications for elite golfers and future research are discussed. PMID:27630588
NASA Astrophysics Data System (ADS)
Xiong, Ling; Luo, Xiao; Hu, Hai-xiang; Zhang, Zhi-yu; Zhang, Feng; Zheng, Li-gong; Zhang, Xue-jun
2017-08-01
A feasible way to improve the manufacturing efficiency of large reaction-bonded silicon carbide optics is to increase the processing accuracy in the ground stage before polishing, which requires high accuracy metrology. A swing arm profilometer (SAP) has been used to measure large optics during the ground stage. A method has been developed for improving the measurement accuracy of SAP using a capacitive probe and implementing calibrations. The experimental result compared with the interferometer test shows the accuracy of 0.068 μm in root-mean-square (RMS) and maps in 37 low-order Zernike terms show accuracy of 0.048 μm RMS, which shows a powerful capability to provide a major input in high-precision grinding.
Skull base tumors: a comprehensive review of transfacial swing osteotomy approaches.
Moreira-Gonzalez, Andrea; Pieper, Daniel R; Cambra, Jorge Balaguer; Simman, Richard; Jackson, Ian T
2005-03-01
Numerous techniques have been proposed for the resection of skull base tumors, each one unique with regard to the region exposed and degree of technical complexity. This study describes the use of transfacial swing osteotomies in accessing lesions located at various levels of the cranial base. Eight patients who underwent transfacial swings for exposure and resection of cranial base lesions between 1996 and 2002 were studied. The mandible was the choice when wide exposure of nasopharyngeal and midline skull base tumors was necessary, especially when they involved the infratemporal fossa. The midfacial swing osteotomy was an option when access to the entire clivus was necessary. An orbital swing approach was used to access large orbital tumors lying inferior to the optic nerve and posterior to the globe, a region that is often difficult to visualize. Gross total tumor excision was possible in all patients. Six patients achieved disease control and two had recurrences. The complications of cerebrospinal fluid leak, infection, hematoma, or cranial nerve damage did not occur. After surgery, some patients experienced temporary symptoms caused by local swelling. The aesthetic result was considered good. Transfacial swing osteotomies provide a wide exposure to tumors that occur in the central skull base area. Excellent knowledge of the detailed anatomy of this region is paramount to the success of this surgery. The team concept is essential; it is built around the craniofacial surgeon and an experienced skull base neurosurgeon.
Kinetic and Kinematic Differences in a Golf Swing in One and Both Lower Limb Amputees
Stastny, Petr; Maszczyk, Adam; Tománková, Kristina; Kubový, Petr; Richtrová, Michaela; Otáhal, Jakub; Čichoň, Rostislav; Mostowik, Aleksandra; Żmijewski, Piotr; Cięszczyk, Paweł
2015-01-01
Amputee golfers need to cope with the absence of sole proprioception, a decreased range of swing motion and other factors which should be recognized for training purposes. The aim of this study was to determine the kinetic and kinematic differences in the golf swing in one leg and two legs amputees. The participants consisted of two males and one female at a professional or amateur level with a different degree of disability. Each participant was taped by 3D markers and performed five golf swings with the iron 6. The intraclass correlation coefficient (ICC) did not vary between individuals in kinematics, however, it was low in kinetic variables of two leg amputees. The Kendal rank correlation showed a significant relationship between the level of amputation and a large number of kinetic and kinematic variables such as X factor, O factor, S factor and individual body angles. The fluency and similarity of the golf swing did not depend on the level of amputation. One lower limb amputation did not seem to increase movement variability contrary to two lower limb amputation. The most variable parameter was a weight-shift in all golfers. The takeaway and horizontal force angle depended on the level of amputation rather than individual technique, thus, their modification by training may be difficult. Estimation of golf swing „mistakes” in amputees in respect to the leading arm in an early follow or late follow position appeared to be useless. PMID:26834871
Kinetic and Kinematic Differences in a Golf Swing in One and Both Lower Limb Amputees.
Stastny, Petr; Maszczyk, Adam; Tománková, Kristina; Kubový, Petr; Richtrová, Michaela; Otáhal, Jakub; Čichoň, Rostislav; Mostowik, Aleksandra; Żmijewski, Piotr; Cięszczyk, Paweł
2015-11-22
Amputee golfers need to cope with the absence of sole proprioception, a decreased range of swing motion and other factors which should be recognized for training purposes. The aim of this study was to determine the kinetic and kinematic differences in the golf swing in one leg and two legs amputees. The participants consisted of two males and one female at a professional or amateur level with a different degree of disability. Each participant was taped by 3D markers and performed five golf swings with the iron 6. The intraclass correlation coefficient (ICC) did not vary between individuals in kinematics, however, it was low in kinetic variables of two leg amputees. The Kendal rank correlation showed a significant relationship between the level of amputation and a large number of kinetic and kinematic variables such as X factor, O factor, S factor and individual body angles. The fluency and similarity of the golf swing did not depend on the level of amputation. One lower limb amputation did not seem to increase movement variability contrary to two lower limb amputation. The most variable parameter was a weight-shift in all golfers. The takeaway and horizontal force angle depended on the level of amputation rather than individual technique, thus, their modification by training may be difficult. Estimation of golf swing "mistakes" in amputees in respect to the leading arm in an early follow or late follow position appeared to be useless.
NASA Technical Reports Server (NTRS)
Hasseeb, Hashmatullah; Iannetti, Anthony
2017-01-01
A major component of a Martian In-Situ Resource Utilization (ISRU) system is the CO2 acquisition subsystem. This subsystem must be able to extract and separate CO2 at ambient Martian pressures and then output the gas at high pressures for the chemical reactors to generate fuel and oxygen. The Temperature Swing Adsorption (TSA) Pump is a competitive design that can perform this task using heating and cooling cycles in an enclosed volume. The design of this system is explored and analyzed for an output pressure range of 50 kPa to 500 kPa and an adsorption temperature range of -50 C to 40 C while meeting notional requirements for two mission scenarios. Mass and energy consumption results are presented for 2-stage, 3-stage, and 4-stage systems using the following adsorbents: Grace 544 13X, BASF 13X, Grace 522 5A and VSA 10 LiX.
Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development
NASA Technical Reports Server (NTRS)
Padilla, Sebastian; Powers, Aaron; Ball, Tyler; Iacomini, Christie; Paul, Heather, L.
2008-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.
2016-03-30
This illustration shows one possible scenario for the hot, rocky exoplanet called 55 Cancri e, which is nearly two times as wide as Earth. New data from NASA Spitzer Space Telescope show that the planet has extreme temperature swings.
NASA Technical Reports Server (NTRS)
Knox, James C.; Miller, Lee; Campbell, Melissa; Mulloth, Lila; Varghese, Mini
2006-01-01
Accumulation and subsequent compression of carbon dioxide that is removed from the space cabin are two important processes involved in a closed-loop air revitalization scheme of the International Space Station (ISS). The 4-Bed Molecular Sieve (4BMS) of ISS currently operates in an open loop mode without a compressor. The Sabatier Engineering Development Unit (EDU) processes waste CO2 to provide water to the crew. This paper reports the integrated 4BMS, air-cooled Temperature Swing Adsorption Compressor (TSAC), and Sabatier EDU testing. The TSAC prototype was developed at NASA Ames Research Center (ARC). The 4BMS was modified to a functionally flight-like condition at NASA Marshall Space Flight Center (MSFC). Testing was conducted at MSFC. The paper provides details of the TSAC operation at various CO2 loadings and corresponding performance of the 4BMS and Sabatier.
Carbon dioxide pressure swing adsorption process using modified alumina adsorbents
Gaffney, T.R.; Golden, T.C.; Mayorga, S.G.; Brzozowski, J.R.; Taylor, F.W.
1999-06-29
A pressure swing adsorption process for absorbing CO[sub 2] from a gaseous mixture containing CO[sub 2] comprises introducing the gaseous mixture at a first pressure into a reactor containing a modified alumina adsorbent maintained at a temperature ranging from 100 C and 500 C to adsorb CO[sub 2] to provide a CO[sub 2] laden alumina adsorbent and a CO[sub 2] depleted gaseous mixture and contacting the CO[sub 2] laden adsorbent with a weakly adsorbing purge fluid at a second pressure which is lower than the first pressure to desorb CO[sub 2] from the CO[sub 2] laden alumina adsorbent. The modified alumina adsorbent which is formed by depositing a solution having a pH of 3.0 or more onto alumina and heating the alumina to a temperature ranging from 100 C and 600 C, is not degraded by high concentrations of water under process operating conditions. 1 fig.
Performance of High Temperature Operational Amplifier, Type LM2904WH, under Extreme Temperatures
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad; Elbuluk, Malik
2008-01-01
Operation of electronic parts and circuits under extreme temperatures is anticipated in NASA space exploration missions as well as terrestrial applications. Exposure of electronics to extreme temperatures and wide-range thermal swings greatly affects their performance via induced changes in the semiconductor material properties, packaging and interconnects, or due to incompatibility issues between interfaces that result from thermal expansion/contraction mismatch. Electronics that are designed to withstand operation and perform efficiently in extreme temperatures would mitigate risks for failure due to thermal stresses and, therefore, improve system reliability. In addition, they contribute to reducing system size and weight, simplifying its design, and reducing development cost through the elimination of otherwise required thermal control elements for proper ambient operation. A large DC voltage gain (100 dB) operational amplifier with a maximum junction temperature of 150 C was recently introduced by STMicroelectronics [1]. This LM2904WH chip comes in a plastic package and is designed specifically for automotive and industrial control systems. It operates from a single power supply over a wide range of voltages, and it consists of two independent, high gain, internally frequency compensated operational amplifiers. Table I shows some of the device manufacturer s specifications.
Selective O 2 Sorption at Ambient Temperatures via Node Distortions in Sc-MIL-100
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sava Gallis, Dorina F.; Chapman, Karena W.; Rodriguez, Mark A.
2016-05-24
An open pored metal–organic framework (MOF) with oxygen selectivity at exceptionally high temperatures is confirmed by synthesis, sorption, and synchrotron structural analyses. The large-pore MIL-100 framework with access to the metal center (e.g., Sc and Fe) resulted in preferential O2 over N2 gas uptake at temperatures ranging from 77 K to ambient temperatures (258, 298, and 313 K). Most notably, Sc-MIL-100 shows exceptional O2 sorption; pair distribution function analyses indicate that this is due to distortions in the framework owing to the size of Sc atoms, in particular in the trimer metal cluster. Experimental studies also correlate very well withmore » GCMC simulations, confirming more favorable O2-framework interactions at pressures up to 1 bar, due to the close proximity of O2 to the high density of metal centers in the small tetrahedral cages. Both materials maintain their crystallinity upon gas adsorption cycling, are regenerable, and show exceptional promise for use in energy efficient oxygen purification processes, such as Pressure Swing Adsorption.« less
Kwon, Young-Hoo; Como, Christopher S; Singhal, Kunal; Lee, Sangwoo; Han, Ki Hoon
2012-06-01
The purposes of this study were (1) to determine the functional swing plane (FSP) of the clubhead and the motion planes (MPs) of the shoulder/arm points and (2) to assess planarity of the golf swing based on the FSP and the MPs. The swing motions of 14 male skilled golfers (mean handicap = -0.5 +/- 2.0) using three different clubs (driver, 5-iron, and pitching wedge) were captured by an optical motion capture system (250Hz). The FSP and MPs along with their slope/relative inclination and direction/direction of inclination were obtained using a new trajectory-plane fitting method. The slope and direction of the FSP revealed a significant club effect (p < 0.001). The relative inclination and direction of inclination of the MP showed significant point (p < 0.001) and club (p < 0.001) effects and interaction (p < 0.001). Maximum deviations of the points from the FSP revealed a significant point effect (p < 0.001) and point-club interaction (p < 0.001). It was concluded that skilled golfers exhibited well-defined and consistent FSP and MPs, and the shoulder/arm points moved on vastly different MPs and exhibited large deviations from the FSP. Skilled golfers in general exhibited semi-planar downswings with two distinct phases: a transition phase and a planar execution phase.
Low-Power, Chip-Scale, Carbon Dioxide Gas Sensors for Spacesuit Monitoring
NASA Technical Reports Server (NTRS)
Rani, Asha; Shi, Chen; Thomson, Brian; Debnath, Ratan; Wen, Boamei; Motayed, Abhishek; Chullen, Cinda
2018-01-01
N5 Sensors, Inc. through a Small Business Technology Transfer (STTR) contract award has been developing ultra-small, low-power carbon dioxide (CO2) gas sensors, suited for monitoring CO2 levels inside NASA spacesuits. Due to the unique environmental conditions within the spacesuits, such as high humidity, large temperature swings, and operating pressure swings, measurement of key gases relevant to astronaut's safety and health such as(CO2), is quite challenging. Conventional non-dispersive infrared absorption based CO2 sensors present challenges inside the spacesuits due to size, weight, and power constraints, along with the ability to sense CO2 in a high humidity environment. Unique chip-scale, nanoengineered chemiresistive gas-sensing architecture has been developed for this application, which can be operated in a typical space-suite environmental conditions. Unique design combining the selective adsorption properties of the nanophotocatalytic clusters of metal-oxides and metals, provides selective detection of CO2 in high relative humidity conditions. All electronic design provides a compact and low-power solution, which can be implemented for multipoint detection of CO2 inside the spacesuits. This paper will describe the sensor architecture, development of new photocatalytic material for better sensor response, and advanced structure for better sensitivity and shorter response times.
Early Improper Motion Detection in Golf Swings Using Wearable Motion Sensors: The First Approach
Stančin, Sara; Tomažič, Sašo
2013-01-01
This paper presents an analysis of a golf swing to detect improper motion in the early phase of the swing. Led by the desire to achieve a consistent shot outcome, a particular golfer would (in multiple trials) prefer to perform completely identical golf swings. In reality, some deviations from the desired motion are always present due to the comprehensive nature of the swing motion. Swing motion deviations that are not detrimental to performance are acceptable. This analysis is conducted using a golfer's leading arm kinematic data, which are obtained from a golfer wearing a motion sensor that is comprised of gyroscopes and accelerometers. Applying the principal component analysis (PCA) to the reference observations of properly performed swings, the PCA components of acceptable swing motion deviations are established. Using these components, the motion deviations in the observations of other swings are examined. Any unacceptable deviations that are detected indicate an improper swing motion. Arbitrarily long observations of an individual player's swing sequences can be included in the analysis. The results obtained for the considered example show an improper swing motion in early phase of the swing, i.e., the first part of the backswing. An early detection method for improper swing motions that is conducted on an individual basis provides assistance for performance improvement. PMID:23752563
Early improper motion detection in golf swings using wearable motion sensors: the first approach.
Stančin, Sara; Tomažič, Sašo
2013-06-10
This paper presents an analysis of a golf swing to detect improper motion in the early phase of the swing. Led by the desire to achieve a consistent shot outcome, a particular golfer would (in multiple trials) prefer to perform completely identical golf swings. In reality, some deviations from the desired motion are always present due to the comprehensive nature of the swing motion. Swing motion deviations that are not detrimental to performance are acceptable. This analysis is conducted using a golfer's leading arm kinematic data, which are obtained from a golfer wearing a motion sensor that is comprised of gyroscopes and accelerometers. Applying the principal component analysis (PCA) to the reference observations of properly performed swings, the PCA components of acceptable swing motion deviations are established. Using these components, the motion deviations in the observations of other swings are examined. Any unacceptable deviations that are detected indicate an improper swing motion. Arbitrarily long observations of an individual player's swing sequences can be included in the analysis. The results obtained for the considered example show an improper swing motion in early phase of the swing, i.e., the first part of the backswing. An early detection method for improper swing motions that is conducted on an individual basis provides assistance for performance improvement.
Sorbent-based Oxygen Production for Energy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sethi, Vijay
Project DE-FE0024075 deals with the development of a moderate-temperature sorbent-based oxygen production technology. Sorbent-based oxygen production process utilizes oxygen-storage properties of Perovskites to (1) adsorb oxygen from air in a solid sorbent, and (2) release the adsorbed oxygen into a sweep gas such as CO 2 and/or steam for gasification systems or recycled flue gas for oxy-combustion systems. Pure oxygen can be produced by the use of vacuum instead of a sweep gas to affect the pressure swing. By developing more efficient and stable, higher sorption capacity, newer class of materials operating at moderate temperatures this process represents a majormore » advancement in air separation technology. Newly developed perovskite ceramic sorbent materials with order-disorder transition have a higher O 2 adsorption capacity, potentially 200 °C lower operating temperatures, and up to two orders of magnitude faster desorption rates than those used in earlier development efforts. The performance advancements afforded by the new materials lead to substantial savings in capital investment and operational costs. Cost of producing oxygen using sorbents could be as much as 26% lower than VPSA and about 13% lower than a large cryogenic air separation unit. Cost advantage against large cryogenic separation is limited because sorbent-based separation numbers up sorbent modules for achieving the larger capacity.« less
Effect of arm swing strategy on local dynamic stability of human gait.
Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H
2015-02-01
Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.
Frontal Plane Knee Moments in Golf: Effect of Target Side Foot Position at Address
Lynn, Scott K.; Noffal, Guillermo J.
2010-01-01
Golf has the potential to keep people active well into their later years. Injuries to the target side knee have been reported in golfers, yet no mechanisms for these injuries have been proposed. The loads on the knee during the golf swing may be insufficient to cause acute injury, yet they may be a factor in the progression of overuse/degenerative conditions; therefore, research developing swing modifications that may alter loading of the knee is warranted. It has been suggested that the proper golf set-up position has the target-side foot externally rotated but no reasoning for this modification has been provided. Frontal plane knee moments have been implicated in many knee pathologies. Therefore, this study used a 3-dimensional link segment model to quantify the frontal plane knee moments during the golf swing in a straight (STR) and externally rotated (EXT) target-side foot position. Subjects were 7 collegiate golfers and knee moments were compared between conditions using repeated measures T-tests. The golf swing knee moment magnitudes were also descriptively compared to those reported for two athletic maneuvers (drop jump landing, side-step cutting) and activities of daily living (gait, stair ascent). The EXT condition decreased the peak knee adduction moment as compared to the STR condition; however, foot position had no effect on the peak knee abduction moment. Also, the magnitude of the knee adduction moments during the two activities of daily living were 9-33% smaller than those experienced during the two different golfing conditions. The drop jump landing and golf swing knee moments were of similar magnitude (STR= - 5%, EXT= + 8%); however, the moments associated with side- step cutting were 50-71% larger than those on the target side knee during the golf swing. The loading of the target side knee during the golf swing may be a factor in the development and progression of knee pathologies and further research should examine ways of attenuating these loads through exercise and swing modifications. Key points An externally rotated front foot position at address would be recommended for those with medial knee pathology in the target side limb. There is a large valgus moment on the target side knee during the golf swing that is not decreased with external rotation of the foot at address. The potential of the knee moments on the target side limb to lead to knee pathologies in golfers needs to be further investigated. PMID:24149696
NASA Astrophysics Data System (ADS)
Ju, Yanqing
2005-11-01
To swing higher and higher, a person on a swing stands up and squats down twice for each swing back and forth. These body movements can increase the mechanical energy of the system. The person on the swing stands on the seat and is propelled by an initial force so that he or she can rise higher and higher by body movement alone. How is this done? If we watch people on swings we see that they usually squat down while the swing goes up to its two highest points, and then stand up quickly when the swing descends to its lowest point. What is the physics behind this?
Tether cutting maneuver in swing-by trajectory
NASA Astrophysics Data System (ADS)
Yamasaki, Tsubasa; Bando, Mai; Hokamoto, Shinji
2018-01-01
The swing-by maneuver is known as a method to change the velocity of a spacecraft by using the gravity force of the celestial body. The powered swing-by has been studied to enhance the velocity change during the swing-by maneuver. This paper studies another way of the powered swing-by using tether cutting, which does not require additional propellant consumption, and shows that the proposed powered swing-by can increase the effect of the swing-by as same as using impulsive thrust. Moreover, it is discussed whether the system has possibility to realize both the powered swing-by of a mother satellite and the planetary capture of a subsatellite simultaneously.
NASA Technical Reports Server (NTRS)
Iacomini, Christine; Powers, Aaron; Bowers, Chad; Straub-Lopez, Katie; Anderson, Grant; MacCallum, Taber; Paul, Heather
2007-01-01
Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of CO2 in an environment with a ppCO2 of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (195K) removes metabolically-produced CO2 in the vent loop. Once fully loaded, the adsorbent is then warmed externally by the vent loop (approx. 300K), rejecting the captured CO2 to Mars ambient. Two beds are used to effect a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the vent loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available at Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments was conducted which lead to the selection and partial characterization of an appropriate adsorbent. The adsorbent NaX successfully removed CO2 from a simulated vent loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design challenges as listed in the conclusions.
Carbon dioxide pressure swing adsorption process using modified alumina adsorbents
Gaffney, Thomas Richard; Golden, Timothy Christopher; Mayorga, Steven Gerard; Brzozowski, Jeffrey Richard; Taylor, Fred William
1999-01-01
A pressure swing adsorption process for absorbing CO.sub.2 from a gaseous mixture containing CO.sub.2 comprising introducing the gaseous mixture at a first pressure into a reactor containing a modified alumina adsorbent maintained at a temperature ranging from 100.degree. C. and 500.degree. C. to adsorb CO.sub.2 to provide a CO.sub.2 laden alumina adsorbent and a CO.sub.2 depleted gaseous mixture and contacting the CO.sub.2 laden adsorbent with a weakly adsorbing purge fluid at a second pressure which is lower than the first pressure to desorb CO.sub.2 from the CO.sub.2 laden alumina adsorbent. The modified alumina adsorbent which is formed by depositing a solution having a pH of 3.0 or more onto alumina and heating the alumina to a temperature ranging from 100.degree. C. and 600.degree. C., is not degraded by high concentrations of water under process operating conditions.
Advanced Acid Gas Separation Technology for the Utilization of Low Rank Coals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kloosterman, Jeff
2012-12-31
Air Products has developed a potentially ground-breaking technology – Sour Pressure Swing Adsorption (PSA) – to replace the solvent-based acid gas removal (AGR) systems currently employed to separate sulfur containing species, along with CO{sub 2} and other impurities, from gasifier syngas streams. The Sour PSA technology is based on adsorption processes that utilize pressure swing or temperature swing regeneration methods. Sour PSA technology has already been shown with higher rank coals to provide a significant reduction in the cost of CO{sub 2} capture for power generation, which should translate to a reduction in cost of electricity (COE), compared to baselinemore » CO{sub 2} capture plant design. The objective of this project is to test the performance and capability of the adsorbents in handling tar and other impurities using a gaseous mixture generated from the gasification of lower rank, lignite coal. The results of this testing are used to generate a high-level pilot process design, and to prepare a techno-economic assessment evaluating the applicability of the technology to plants utilizing these coals.« less
2009-08-17
aluminum bolted to aluminum specimens. 2. Similarly to the temperature effects on the response of the specimens tested, relative humidity swings have a...bolted to aluminum specimens show the highest susceptibility to relative humidity shifts. This response is believed to be related to their ability to...relaxation stage, little effects are detected from relative humidity fluctuations. 81 9. The data
Temperature Variations Recorded During Interinstitutional Air Shipments of Laboratory Mice
Syversen, Eric; Pineda, Fernando J; Watson, Julie
2008-01-01
Despite extensive guidelines and regulations that govern most aspects of rodent shipping, few data are available on the physical environment experienced by rodents during shipment. To document the thermal environment experienced by mice during air shipments, we recorded temperatures at 1-min intervals throughout 103 routine interinstitutional shipments originating at our institution. We found that 49.5% of shipments were exposed to high temperatures (greater than 29.4 °C), 14.6% to low temperatures (less than 7.2 °C), and 61% to temperature variations of 11 °C or more. International shipments were more likely than domestic shipments to experience temperature extremes and large variations in temperature. Freight forwarders using passenger airlines rather than their own airplanes were more likely to have shipments that experienced temperature extremes or variations. Temperature variations were most common during stopovers. Some airlines were more likely than others to experience inflight temperature extremes or swings. Most domestic shipments lasted at least 24 h, whereas international shipments lasted 48 to 72 h. Despite exposure to high and low temperatures, animals in all but 1 shipment arrived alive. We suggest that simple measures, such as shipping at night during hot weather, provision of nesting material in shipping crates, and specifying aircraft cargo-hold temperatures that are suitable for rodents, could reduce temperature-induced stress. Measures such as additional training for airport ground crews, as previously recommended by the American Veterinary Medical Association, could further reduce exposure of rodents to extreme ambient temperatures during airport stopovers. PMID:18210996
Temperature variations recorded during interinstitutional air shipments of laboratory mice.
Syversen, Eric; Pineda, Fernando J; Watson, Julie
2008-01-01
Despite extensive guidelines and regulations that govern most aspects of rodent shipping, few data are available on the physical environment experienced by rodents during shipment. To document the thermal environment experienced by mice during air shipments, we recorded temperatures at 1-min intervals throughout 103 routine interinstitutional shipments originating at our institution. We found that 49.5% of shipments were exposed to high temperatures (greater than 29.4 degrees C), 14.6% to low temperatures (less than 7.2 degrees C), and 61% to temperature variations of 11 degrees C or more. International shipments were more likely than domestic shipments to experience temperature extremes and large variations in temperature. Freight forwarders using passenger airlines rather than their own airplanes were more likely to have shipments that experienced temperature extremes or variations. Temperature variations were most common during stopovers. Some airlines were more likely than others to experience inflight temperature extremes or swings. Most domestic shipments lasted at least 24 h, whereas international shipments lasted 48 to 72 h. Despite exposure to high and low temperatures, animals in all but 1 shipment arrived alive. We suggest that simple measures, such as shipping at night during hot weather, provision of nesting material in shipping crates, and specifying aircraft cargo-hold temperatures that are suitable for rodents, could reduce temperature-induced stress. Measures such as additional training for airport ground crews, as previously recommended by the American Veterinary Medical Association, could further reduce exposure of rodents to extreme ambient temperatures during airport stopovers.
Microstructure and conductance-slope of InAs/GaSb tunnel diodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iutzi, Ryan M., E-mail: iutzi@mit.edu; Fitzgerald, Eugene A.
2014-06-21
InAs/GaSb and similar materials systems have generated great interest as a heterojunction for tunnel field effect transistors (TFETs) due to favorable band alignment. However, little is currently understood about how such TFETs are affected by materials defects and nonidealities. We present measurements of the conductance slope for various InAs/GaSb heterojunctions via two-terminal electrical measurements, which removes three-terminal parasitics and enables direct study on the effect of microstructure on tunnelling. Using this, we can predict how subthreshold swings in TFETs can depend on microstructure. We also demonstrate growth and electrical characterization for structures grown by metalorganic chemical vapor deposition (MOCVD)—a generallymore » more scalable process compared with molecular beam epitaxy (MBE). We determine that misfit dislocations and point defects near the interface can lead to energy states in the band-gap and local band bending that result in trap-assisted leakage routes and nonuniform band alignment across the junction area that lower the steepness of the conductance slope. Despite the small lattice mismatch, misfit dislocations still form in InAs on GaSb due to relaxation as a result of large strain from intermixed compositions. This can be circumvented by growing GaSb on InAs, straining the GaSb underlayer, or lowering the InAs growth temperature in the region of the interface. The conductance slope can also be improved by annealing the samples at higher temperatures, which we believe acts to annihilate point defects and average out major fluctuations in band alignment across the interface. Using a combination of these techniques, we can greatly improve the steepness of the conductance slope which could result in steeper subthreshold swings in TFETs in the future.« less
Intelligent Power Swing Detection Scheme to Prevent False Relay Tripping Using S-Transform
NASA Astrophysics Data System (ADS)
Mohamad, Nor Z.; Abidin, Ahmad F.; Musirin, Ismail
2014-06-01
Distance relay design is equipped with out-of-step tripping scheme to ensure correct distance relay operation during power swing. The out-of-step condition is a consequence result from unstable power swing. It requires proper detection of power swing to initiate a tripping signal followed by separation of unstable part from the entire power system. The distinguishing process of unstable swing from stable swing poses a challenging task. This paper presents an intelligent approach to detect power swing based on S-Transform signal processing tool. The proposed scheme is based on the use of S-Transform feature of active power at the distance relay measurement point. It is demonstrated that the proposed scheme is able to detect and discriminate the unstable swing from stable swing occurring in the system. To ascertain validity of the proposed scheme, simulations were carried out with the IEEE 39 bus system and its performance has been compared with the wavelet transform-based power swing detection scheme.
NASA Astrophysics Data System (ADS)
Merlaud, Alexis; Tack, Frederik; Constantin, Daniel; Georgescu, Lucian; Maes, Jeroen; Fayt, Caroline; Mingireanu, Florin; Schuettemeyer, Dirk; Meier, Andreas Carlos; Schönardt, Anja; Ruhtz, Thomas; Bellegante, Livio; Nicolae, Doina; Den Hoed, Mirjam; Allaart, Marc; Van Roozendael, Michel
2018-01-01
The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) is a compact remote sensing instrument dedicated to mapping trace gases from an unmanned aerial vehicle (UAV). SWING is based on a compact visible spectrometer and a scanning mirror to collect scattered sunlight. Its weight, size, and power consumption are respectively 920 g, 27 cm × 12 cm × 8 cm, and 6 W. SWING was developed in parallel with a 2.5 m flying-wing UAV. This unmanned aircraft is electrically powered, has a typical airspeed of 100 km h-1, and can operate at a maximum altitude of 3 km. We present SWING-UAV experiments performed in Romania on 11 September 2014 during the Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaign, which was dedicated to test newly developed instruments in the context of air quality satellite validation. The UAV was operated up to 700 m above ground, in the vicinity of the large power plant of Turceni (44.67° N, 23.41° E; 116 m a. s. l. ). These SWING-UAV flights were coincident with another airborne experiment using the Airborne imaging differential optical absorption spectroscopy (DOAS) instrument for Measurements of Atmospheric Pollution (AirMAP), and with ground-based DOAS, lidar, and balloon-borne in situ observations. The spectra recorded during the SWING-UAV flights are analysed with the DOAS technique. This analysis reveals NO2 differential slant column densities (DSCDs) up to 13±0.6×1016 molec cm-2. These NO2 DSCDs are converted to vertical column densities (VCDs) by estimating air mass factors. The resulting NO2 VCDs are up to 4.7±0.4×1016 molec cm-2. The water vapour DSCD measurements, up to 8±0.15×1022 molec cm-2, are used to estimate a volume mixing ratio of water vapour in the boundary layer of 0.013±0.002 mol mol-1. These geophysical quantities are validated with the coincident measurements.
Surface Power Radiative Cooling Tests
NASA Astrophysics Data System (ADS)
Vaughn, Jason; Schneider, Todd
2006-01-01
Terrestrial nuclear power plants typically maintain their temperature through convective cooling, such as water and forced air. However, the space environment is a vacuum environment, typically 10-8 Torr pressure, therefore in proposed missions to the lunar surface, power plants would have to rely on radiative cooling to remove waste heat. Also, the Martian surface has a very tenuous atmosphere (e.g. ~5 Torr CO2), therefore, the main heat transfer method on the Martian surface is also radiative. Because of the lack of atmosphere on the Moon and the tenuous atmosphere on Mars, surface power systems on both the Lunar and Martian surface must rely heavily on radiative heat transfer. Because of the large temperature swings on both the lunar and the Martian surfaces, trying to radiate heat is inefficient. In order to increase power system efficiency, an effort is underway to test various combinations of materials with high emissivities to demonstrate their ability to survive these degrading atmospheres to maintain a constant radiator temperature improving surface power plant efficiency. An important part of this effort is the development of a unique capability that would allow the determination of a materials emissivity at high temperatures. A description of the test capability as well as initial data is presented.
77 FR 7011 - Safety Standard for Infant Swings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-10
... JPMA as compliant with the ASTM voluntary infant swing standard. C. Infant Swings and the ASTM... positioned in the swing seat. c. Description of Proposed Changes The shoulder strap requirement is intended... swing fails the test. c. Description of Proposed Changes The proposed rule would make two changes to the...
Thermo-electrochemical evaluation of lithium-ion batteries for space applications
NASA Astrophysics Data System (ADS)
Walker, W.; Yayathi, S.; Shaw, J.; Ardebili, H.
2015-12-01
Advanced energy storage and power management systems designed through rigorous materials selection, testing and analysis processes are essential to ensuring mission longevity and success for space exploration applications. Comprehensive testing of Boston Power Swing 5300 lithium-ion (Li-ion) cells utilized by the National Aeronautics and Space Administration (NASA) to power humanoid robot Robonaut 2 (R2) is conducted to support the development of a test-correlated Thermal Desktop (TD) Systems Improved Numerical Differencing Analyzer (SINDA) (TD-S) model for evaluation of power system thermal performance. Temperature, current, working voltage and open circuit voltage measurements are taken during nominal charge-discharge operations to provide necessary characterization of the Swing 5300 cells for TD-S model correlation. Building from test data, embedded FORTRAN statements directly simulate Ohmic heat generation of the cells during charge-discharge as a function of surrounding temperature, local cell temperature and state of charge. The unique capability gained by using TD-S is demonstrated by simulating R2 battery thermal performance in example orbital environments for hypothetical extra-vehicular activities (EVA) exterior to a small satellite. Results provide necessary demonstration of this TD-S technique for thermo-electrochemical analysis of Li-ion cells operating in space environments.
Hamai, Satoshi; Miura, Hiromasa; Higaki, Hidehiko; Shimoto, Takeshi; Matsuda, Shuichi; Okazaki, Ken; Iwamoto, Yukihide
2008-12-01
The expectation of returning to sports activities after total knee arthroplasty (TKA) has become more important to patients than ever. To our knowledge, no studies have been published evaluating the three-dimensional knee joint kinematics during sports activity after TKA. Continuous X-ray images of the golf swing and stationary cycling were taken using a large flat panel detector for four and eight post-arthroplasty knees, respectively. The implant flexion and axial rotation angles were determined using a radiographic-based, image-matching technique. Both the golf swing from the set-up position to the top of the backswing, and the stationary cycling from the top position of the crank to the bottom position of the crank, produced progressive axial rotational motions (p = 0.73). However, the golf swing from the top of the backswing to the end of the follow-through produced significantly larger magnitudes of rotational motions in comparison to stationary cycling (p < 0.01). Excessive internal-external rotations generated from the top of the backswing to the end of the follow-through could contribute to accelerated polyethylene wear. However, gradual rotational movements were consistently demonstrated during the stationary cycling. Therefore, stationary cycling is recommended rather than playing golf for patients following a TKA who wish to remain physically active.
3. This series of photographs (3 through 9) illustrates the ...
3. This series of photographs (3 through 9) illustrates the operation of the swing bridge. In #3 the bridge is in its closed position. #3 4,5,&6 the boat whistles and requests passage. the bridge is closed to traffice. The bridge operator, stationed in the center of the tenders house at the center of the truss releases the pneumatic jack. The rollers beneath the deck. swing upward and the electric-powered turntable swings the bobtail drawn in the direction of the oncoming vessel. In #7 a tugboat enters the channel. In #8 a much-lightened ore carrier which has delivered its cargo to the steel mills upriver(note the high water mark), makes its way down-river towards Lake Erie. Such boats are too large to turn around on the narrow Cuyahoga, so they go out backwards, pulled by a tug. in #9 the the ore-carrier clears the channel. In #10 As soon as the boat clears the bridge, the bridge tender begins to close it. The bridge is opened in the direction of an oncoming vessel so that it can be closed even as the boat is leaving the channel; thus surface traffic on Center Street suffers the least possible interruption. - Center Street Swing Bridge, Southwest of Public Square, Cleveland, Cuyahoga County, OH
Comparative M-H Characteristics of 1-5 and 2-17 Type Samarium-Cobalt Permanent Magnets to 300 C
NASA Technical Reports Server (NTRS)
Niedra, Janis M.
1994-01-01
Recent consideration of the use of permanent magnets in space power converters at heat rejection temperatures exceeding 250 C and in miniature high temperature actuators is supporting a search for permanent magnets resistant to demagnetizing forces at high temperature. The present paper investigates the short-term demagnetization resistance to applied bucking fields and at temperatures up to 300 C of SmCo5 type magnets, in the form of 1-cm cubes, from several commercial sources. Quasistatic, 2nd quadrant M-H data taken at selected temperatures are the source of derived plots which are then compared to similar data for previously tested Sm2Co17 type magnets. The 1-5 magnet remanence tends to be about 1.5 kG below that of the 2-17 magnets throughout the temperature range. However, the intrinsic coercivities and M-H curve 'knee-fields' seen in particular 1-5 magnets were considerably above those seen previously in the 2-17 magnets. This superior resistance to demagnetizing fields attainable in 1-5 magnets is also illustrated by safe operating area plots based on the knee-field, the magnetic induction swing and temperature. Comments are made on the possibility that a remanence versus knee-field tradeoff can make 1-5 material competitive with 2-17 in applications where a magnet has to withstand large bucking fields at high temperature.
Large seasonal swings in leaf area of Amazon rainforests
Myneni, Ranga B.; Yang, Wenze; Nemani, Ramakrishna R.; Huete, Alfredo R.; Dickinson, Robert E.; Knyazikhin, Yuri; Didan, Kamel; Fu, Rong; Negrón Juárez, Robinson I.; Saatchi, Sasan S.; Hashimoto, Hirofumi; Ichii, Kazuhito; Shabanov, Nikolay V.; Tan, Bin; Ratana, Piyachat; Privette, Jeffrey L.; Morisette, Jeffrey T.; Vermote, Eric F.; Roy, David P.; Wolfe, Robert E.; Friedl, Mark A.; Running, Steven W.; Votava, Petr; El-Saleous, Nazmi; Devadiga, Sadashiva; Su, Yin; Salomonson, Vincent V.
2007-01-01
Despite early speculation to the contrary, all tropical forests studied to date display seasonal variations in the presence of new leaves, flowers, and fruits. Past studies were focused on the timing of phenological events and their cues but not on the accompanying changes in leaf area that regulate vegetation–atmosphere exchanges of energy, momentum, and mass. Here we report, from analysis of 5 years of recent satellite data, seasonal swings in green leaf area of ≈25% in a majority of the Amazon rainforests. This seasonal cycle is timed to the seasonality of solar radiation in a manner that is suggestive of anticipatory and opportunistic patterns of net leaf flushing during the early to mid part of the light-rich dry season and net leaf abscission during the cloudy wet season. These seasonal swings in leaf area may be critical to initiation of the transition from dry to wet season, seasonal carbon balance between photosynthetic gains and respiratory losses, and litterfall nutrient cycling in moist tropical forests. PMID:17360360
33 CFR 118.70 - Lights on swing bridges.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Lights on swing bridges. 118.70... LIGHTING AND OTHER SIGNALS § 118.70 Lights on swing bridges. (a) Swing span lights on through bridges. Each... an approaching vessel the swing span when closed will display three red lights on top of the span...
33 CFR 118.70 - Lights on swing bridges.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Lights on swing bridges. 118.70... LIGHTING AND OTHER SIGNALS § 118.70 Lights on swing bridges. (a) Swing span lights on through bridges. Each... an approaching vessel the swing span when closed will display three red lights on top of the span...
33 CFR 118.70 - Lights on swing bridges.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Lights on swing bridges. 118.70... LIGHTING AND OTHER SIGNALS § 118.70 Lights on swing bridges. (a) Swing span lights on through bridges. Each... an approaching vessel the swing span when closed will display three red lights on top of the span...
33 CFR 118.70 - Lights on swing bridges.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Lights on swing bridges. 118.70... LIGHTING AND OTHER SIGNALS § 118.70 Lights on swing bridges. (a) Swing span lights on through bridges. Each... an approaching vessel the swing span when closed will display three red lights on top of the span...
20. Detail view of west swing span abutment through swing ...
20. Detail view of west swing span abutment through swing span truss, looking north - India Point Railroad Bridge, Spanning Seekonk River between Providence & East Providence, Providence, Providence County, RI
Effect of active arm swing to local dynamic stability during walking.
Wu, Yu; Li, Yue; Liu, An-Min; Xiao, Fei; Wang, Yin-Zhi; Hu, Fei; Chen, Jin-Ling; Dai, Ke-Rong; Gu, Dong-Yun
2016-02-01
Arm swing is an essential component in regulating dynamic stability of the whole body during walking, while the contribution of active arm swing to local dynamic stability of different motion segments remains unclear. This study investigated the effects of arm swing under natural arm swing condition and active arm swing condition on local dynamic stability and gait variability of the trunk segments (C7 and T10 joint) and lower extremity joints (hip, knee and ankle joint). The local divergence exponents (λs) and mean standard deviation over strides (MeanSD) of 24 young healthy adults were calculated while they were walking on treadmill with two arm swing conditions at their preferred walking speed (PWS). We found that in medial-lateral direction, both λs and MeanSD values of the trunk segments (C7 and T10 joint) in active arm swing condition were significantly lower than those in natural arm swing condition (p<0.05), while no significant difference of λs or MeanSD in lower extremity joints (hip, knee and ankle joint) was found between two arm swing conditions (p>0.05, respectively). In anterior-posterior and vertical direction, neither λs nor MeanSD values of all body segments showed significant difference between two arm swing conditions (p>0.05, respectively). These findings indicate that active arm swing may help to improve the local dynamic stability of the trunk segments in medial-lateral direction. Copyright © 2015 Elsevier B.V. All rights reserved.
Effect of temperature on the characteristics of silicon nanowire transistor.
Hashim, Yasir; Sidek, Othman
2012-10-01
This paper presents the temperature characteristics of silicon nanowire transistors (SiNWTs) and examines the effect of temperature on transfer characteristics, threshold voltage, I(ON)/I(OFF) ratio, drain-induced barrier lowering (DIBL), and sub-threshold swing (SS). The (MuGFET) simulation tool was used to investigate the temperature characteristics of a transistor. The findings reveal the negative effect of higher working temperature on the use of SiNWTs in electronic circuits, such as digital circuits and amplifiers circuits, because of the lower I(ON)/I(OFF) ratio, higher DIBL, and higher SS at higher temperature. Moreover, the ON state is the optimum condition for using a transistor as a temperature nano-sensor.
Dopaminergic modulation of arm swing during gait among Parkinson’s disease patients
Sterling, Nicholas W.; Cusumano, Joseph P.; Shaham, Noam; Piazza, Stephen J.; Liu, Guodong; Kong, Lan; Du, Guangwei; Lewis, Mechelle M.; Huang, Xuemei
2015-01-01
Background Reduced arm swing amplitude, symmetry, and coordination during gait have been reported in Parkinson’s disease (PD), but the relationship between dopaminergic depletion and these upper limb gait changes remains unclear. This study investigated the effects of dopaminergic drugs on arm swing velocity, symmetry, and coordination in PD. Methods Forearm angular velocity was recorded in 16 PD and 17 control subjects (Controls) during free walking trials. Angular velocity amplitude of each arm, arm swing asymmetry, and maximum cross-correlation were compared between control and PD groups, and between OFF- and ON-medication states among PD subjects. Results Compared to Controls, PD subjects in the OFF-medication state exhibited lower angular velocity amplitude of the slower- (p=0.0018), but not faster- (p=0.2801) swinging arm. In addition, PD subjects demonstrated increased arm swing asymmetry (p=0.0046) and lower maximum cross-correlation (p=0.0026). Following dopaminergic treatment, angular velocity amplitude increased in the slower- (p=0.0182), but not faster- (p=0.2312) swinging arm among PD subjects. Furthermore, arm swing asymmetry decreased (p=0.0386), whereas maximum cross-correlation showed no change (p=0.7436). Pre-drug angular velocity amplitude of the slower-swinging arm was correlated inversely with the change in arm swing asymmetry (R=−0.73824, p=0.0011). Conclusions This study provides quantitative evidence that reduced arm swing and symmetry in PD can be modulated by dopaminergic replacement. The lack of modulations of bilateral arm coordination suggests that additional neurotransmitters may also be involved in arm swing changes in PD. Further studies are warranted to investigate the longitudinal trajectory of arm swing dynamics throughout PD progression. PMID:25502948
Dopaminergic modulation of arm swing during gait among Parkinson's disease patients.
Sterling, Nicholas W; Cusumano, Joseph P; Shaham, Noam; Piazza, Stephen J; Liu, Guodong; Kong, Lan; Du, Guangwei; Lewis, Mechelle M; Huang, Xuemei
2015-01-01
Reduced arm swing amplitude, symmetry, and coordination during gait have been reported in Parkinson's disease (PD), but the relationship between dopaminergic depletion and these upper limb gait changes remains unclear. We aimed to investigate the effects of dopaminergic drugs on arm swing velocity, symmetry, and coordination in PD. Forearm angular velocity was recorded in 16 PD and 17 control subjects (Controls) during free walking trials. Angular velocity amplitude of each arm, arm swing asymmetry, and maximum cross-correlation were compared between control and PD groups, and between OFF- and ON-medication states among PD subjects. Compared to Controls, PD subjects in the OFF-medication state exhibited lower angular velocity amplitude of the slower- (p = 0.0018), but not faster- (p = 0.2801) swinging arm. In addition, PD subjects demonstrated increased arm swing asymmetry (p = 0.0046) and lower maximum cross-correlation (p = 0.0026). Following dopaminergic treatment, angular velocity amplitude increased in the slower- (p = 0.0182), but not faster- (p = 0.2312) swinging arm among PD subjects. Furthermore, arm swing asymmetry decreased (p = 0.0386), whereas maximum cross-correlation showed no change (p = 0.7436). Pre-drug angular velocity amplitude of the slower-swinging arm was correlated inversely with the change in arm swing asymmetry (R = -0.73824, p = 0.0011). This study provides quantitative evidence that reduced arm swing and symmetry in PD can be modulated by dopaminergic replacement. The lack of modulations of bilateral arm coordination suggests that additional neurotransmitters may also be involved in arm swing changes in PD. Further studies are warranted to investigate the longitudinal trajectory of arm swing dynamics throughout PD progression.
Qiu, Chenguang; Zhang, Zhiyong; Zhong, Donglai; Si, Jia; Yang, Yingjun; Peng, Lian-Mao
2015-01-27
Field-effect transistors (FETs) based on moderate or large diameter carbon nanotubes (CNTs) usually suffer from ambipolar behavior, large off-state current and small current on/off ratio, which are highly undesirable for digital electronics. To overcome these problems, a feedback-gate (FBG) FET structure is designed and tested. This FBG FET differs from normal top-gate FET by an extra feedback-gate, which is connected directly to the drain electrode of the FET. It is demonstrated that a FBG FET based on a semiconducting CNT with a diameter of 1.5 nm may exhibit low off-state current of about 1 × 10(-13) A, high current on/off ratio of larger than 1 × 10(8), negligible drain-induced off-state leakage current, and good subthreshold swing of 75 mV/DEC even at large source-drain bias and room temperature. The FBG structure is promising for CNT FETs to meet the standard for low-static-power logic electronics applications, and could also be utilized for building FETs using other small band gap semiconductors to suppress leakage current.
The metabolic cost of human running: is swinging the arms worth it?
Arellano, Christopher J; Kram, Rodger
2014-07-15
Although the mechanical function is quite clear, there is no consensus regarding the metabolic benefit of arm swing during human running. We compared the metabolic cost of running using normal arm swing with the metabolic cost of running while restricting the arms in three different ways: (1) holding the hands with the arms behind the back in a relaxed position (BACK), (2) holding the arms across the chest (CHEST) and (3) holding the hands on top of the head (HEAD). We hypothesized that running without arm swing would demand a greater metabolic cost than running with arm swing. Indeed, when compared with running using normal arm swing, we found that net metabolic power demand was 3, 9 and 13% greater for the BACK, CHEST and HEAD conditions, respectively (all P<0.05). We also found that when running without arm swing, subjects significantly increased the peak-to-peak amplitudes of both shoulder and pelvis rotation about the vertical axis, most likely a compensatory strategy to counterbalance the rotational angular momentum of the swinging legs. In conclusion, our findings support our general hypothesis that swinging the arms reduces the metabolic cost of human running. Our findings also demonstrate that arm swing minimizes torso rotation. We infer that actively swinging the arms provides both metabolic and biomechanical benefits during human running. © 2014. Published by The Company of Biologists Ltd.
The effects of the arm swing on biomechanical and physiological aspects of roller ski skating.
Hegge, Ann Magdalen; Ettema, Gertjan; de Koning, Jos J; Rognstad, Asgeir Bakken; Hoset, Martin; Sandbakk, Øyvind
2014-08-01
This study analyzed the biomechanical and physiological effects of the arm swing in roller ski skating, and compared leg-skating (i.e. ski skating without poles) using a pronounced arm swing (SWING) with leg-skating using locked arms (LOCKED). Sixteen elite male cross-country skiers performed submaximal stages at 10, 15 and 20kmh(-1) on a 2% inclined treadmill in the two techniques. SWING demonstrated higher peak push-off forces and a higher force impulse at all speeds, but a longer cycle length only at the highest speed (all P<.05), indicating a lower force effectiveness with SWING at the two lowest speeds. Additionally, the flexion-extension movement in the lower limbs was more pronounced for SWING. Oxygen uptake was higher for SWING at the two lowest speeds (both P<.05) without any differences in blood lactate. At the highest speed, oxygen uptake did not differ between SWING and LOCKED, but the RER, blood lactate and ventilation were lower with SWING (all P<.05). Taken together, these results demonstrate that utilizing the arm swing in roller ski skating increases the ski forces and aerobic energy cost at low and moderate speeds, whereas the greater forces at high speed lead to a longer cycle length and smaller anaerobic contribution. Copyright © 2014 Elsevier B.V. All rights reserved.
Transparent Thin-Film Transistors Based on Sputtered Electric Double Layer
Cai, Wensi; Ma, Xiaochen; Zhang, Jiawei; Song, Aimin
2017-01-01
Electric-double-layer (EDL) thin-film transistors (TFTs) have attracted much attention due to their low operation voltages. Recently, EDL TFTs gated with radio frequency (RF) magnetron sputtered SiO2 have been developed which is compatible to large-area electronics fabrication. In this work, fully transparent Indium-Gallium-Zinc-Oxide-based EDL TFTs on glass substrates have been fabricated at room temperature for the first time. A maximum transmittance of about 80% has been achieved in the visible light range. The transparent TFTs show a low operation voltage of 1.5 V due to the large EDL capacitance (0.3 µF/cm2 at 20 Hz). The devices exhibit a good performance with a low subthreshold swing of 130 mV/dec and a high on-off ratio > 105. Several tests have also been done to investigate the influences of light irradiation and bias stress. Our results suggest that such transistors might have potential applications in battery-powered transparent electron devices. PMID:28772789
Transparent Thin-Film Transistors Based on Sputtered Electric Double Layer.
Cai, Wensi; Ma, Xiaochen; Zhang, Jiawei; Song, Aimin
2017-04-20
Electric-double-layer (EDL) thin-film transistors (TFTs) have attracted much attention due to their low operation voltages. Recently, EDL TFTs gated with radio frequency (RF) magnetron sputtered SiO₂ have been developed which is compatible to large-area electronics fabrication. In this work, fully transparent Indium-Gallium-Zinc-Oxide-based EDL TFTs on glass substrates have been fabricated at room temperature for the first time. A maximum transmittance of about 80% has been achieved in the visible light range. The transparent TFTs show a low operation voltage of 1.5 V due to the large EDL capacitance (0.3 µF/cm² at 20 Hz). The devices exhibit a good performance with a low subthreshold swing of 130 mV/dec and a high on-off ratio > 10⁵. Several tests have also been done to investigate the influences of light irradiation and bias stress. Our results suggest that such transistors might have potential applications in battery-powered transparent electron devices.
a New Golf-Swing Robot Model Utilizing Shaft Elasticity
NASA Astrophysics Data System (ADS)
Suzuki, S.; Inooka, H.
1998-10-01
The performance of golf clubs and balls is generally evaluated by using golf-swing robots that conventionally have two or three joints with completely interrelated motion. This interrelation allows the user of this robot to specify only the initial posture and swing velocity of the robot and therefore the swing motion of this type of robot cannot be subtly adjusted to the specific characteristics of individual golf clubs. Consequently, golf-swing robots cannot accurately emulate advanced golfers, and this causes serious problems for the evaluation of golf club performance. In this study, a new golf-swing robot that can adjust its motion to both a specified value of swing velocity and the specific characteristics of individual golf clubs was analytically investigated. This robot utilizes the dynamic interference force produced by its swing motion and by shaft vibration and can therefore emulate advanced golfers and perform highly reliable evaluations of golf clubs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Byung-Jae; Hwang, Ya-Hsi; Ahn, Shihyun
The recovery effects of thermal annealing on dc and rf performance of off-state step-stressed AlGaN/GaN high electron mobility transistors were investigated. After stress, reverse gate leakage current and sub-threshold swing increased and drain current on-off ratio decreased. However, these degradations were completely recovered after thermal annealing at 450 °C for 10 mins for devices stressed either once or twice. The trap densities, which were estimated by temperature-dependent drain-current sub-threshold swing measurements, increased after off-state step-stress and were reduced after subsequent thermal annealing. In addition, the small signal rf characteristics of stressed devices were completely recovered after thermal annealing.
Murakami, Koji; Hamai, Satoshi; Okazaki, Ken; Ikebe, Satoru; Shimoto, Takeshi; Hara, Daisuke; Mizu-uchi, Hideki; Higaki, Hidehiko; Iwamoto, Yukihide
2016-03-01
Participation in specific activities requires complex ranges of knee movements and activity-dependent kinematics. The purpose of this study was to investigate dynamic knee kinematics during squat and golf swing using image-matching techniques. Five healthy males performed squats and golf swings under periodic X-ray images at 10 frames per second. We analyzed the in vivo three-dimensional kinematic parameters of subjects' knees, namely the tibiofemoral flexion angle, anteroposterior (AP) translation, and internal-external rotation, using serial X-ray images and computed tomography-derived, digitally reconstructed radiographs. During squat from 0° to 140° of flexion, the femur moved about 25 mm posteriorly and rotated 19° externally relative to the tibia. Screw-home movement near extension, bicondylar rollback between 20° and 120° of flexion, and medial pivot motion at further flexion were observed. During golf swing, the leading and trailing knees (the left and right knees respectively in the right-handed golfer) showed approximately five millimeters and four millimeters of AP translation with 18° and 26° of axial rotation, respectively. A central pivot motion from set-up to top of the backswing, lateral pivot motion from top to ball impact, and medial pivot motion from impact to the end of follow-through were observed. The medial pivot motion was not always recognized during both activities, but a large range of axial rotation with bilateral condylar AP translations occurs during golf swing. This finding has important implications regarding the amount of acceptable AP translation and axial rotation at low flexion in replaced knees. IV. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Iacomini, Christie; Powers, Aaron; Speight, Garland; Padilla, Sebastian; Paul, Heather L.
2009-01-01
A Metabolic heat-regenerated Temperature Swing Adsorption (MTSA) system is being developed for carbon dioxide, water and thermal control in a lunar and martian portable life support system (PLSS). A previous system analysis was performed to evaluate the impact of MTSA on PLSS design. That effort was Mars specific and assumed liquid carbon dioxide (LCO2) coolant made from martian resources. Transient effects were not considered but rather average conditions were used throughout the analysis. This effort takes into further consideration the transient effects inherent in the cycling MTSA system as well as assesses the use of water as coolant. Standard heat transfer, thermodynamic, and heat exchanger methods are presented to conduct the analysis. Assumptions and model verification are discussed. The tool was used to perform various system studies. Coolant selection was explored and takes into account different operational scenarios as the minimum bed temperature is driven by the sublimation temperature of the coolant (water being significantly higher than LCO2). From this, coolant mass is sized coupled with sorbent bed mass because MTSA adsorption performance decreases with increasing sublimation temperature. Reduction in heat exchanger performance and even removal of certain heat exchangers, like a recuperative one between the two sorbent beds, is also investigated. Finally, the coolant flow rate is varied over the cycle to determine if there is a more optimal means of cooling the bed from a mass perspective. Results of these studies and subsequent recommendations for system design are presented.
Development of a Temperature Sensor for Jet Engine and Space Missions Environments
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad; Culley, Dennis E.; Elbuluk, Malik
2008-01-01
Electronic systems in aerospace and in space exploration missions are expected to encounter extreme temperatures and wide thermal swings. To address the needs for extreme temperature electronics, research efforts exist at the NASA Glenn Research Center (GRC) to develop and evaluate electronics for extreme temperature operations, and to establish their reliability under extreme temperature operation and thermal cycling; conditions that are typical of both the aerospace and space environments. These efforts are supported by the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program and by the NASA Electronic Parts and Packaging (NEPP) Program. This work reports on the results obtained on the development of a temperature sensor geared for use in harsh environments.
Convolutional Architecture Exploration for Action Recognition and Image Classification
2015-01-01
that has 200 videos taken in 720x480 resolution of 9 different sporting activities: diving, golf , swinging , kicking, lifting, horseback riding, running...sporting activities: diving, golf swinging , kicking, lifting, horseback riding, running, skateboarding, swinging (various gymnastics), and walking. In this...Testing Videos Diving 13 3 Golf Swinging 21 4 Horseback Riding 11 3 Kicking 21 4 Lifting 12 3 Running 12 3 Skateboarding 12 3 Swinging (Gymnastics) 28
A Three Dimensional Kinematic and Kinetic Study of the Golf Swing
Nesbit, Steven M.
2005-01-01
This paper discusses the three-dimensional kinematics and kinetics of a golf swing as performed by 84 male and one female amateur subjects of various skill levels. The analysis was performed using a variable full-body computer model of a human coupled with a flexible model of a golf club. Data to drive the model was obtained from subject swings recorded using a multi-camera motion analysis system. Model output included club trajectories, golfer/club interaction forces and torques, work and power, and club deflections. These data formed the basis for a statistical analysis of all subjects, and a detailed analysis and comparison of the swing characteristics of four of the subjects. The analysis generated much new data concerning the mechanics of the golf swing. It revealed that a golf swing is a highly coordinated and individual motion and subject-to-subject variations were significant. The study highlighted the importance of the wrists in generating club head velocity and orienting the club face. The trajectory of the hands and the ability to do work were the factors most closely related to skill level. Key Points Full-body model of the golf swing. Mechanical description of the golf swing. Statistical analysis of golf swing mechanics. Comparisons of subject swing mechanics PMID:24627665
A three dimensional kinematic and kinetic study of the golf swing.
Nesbit, Steven M
2005-12-01
This paper discusses the three-dimensional kinematics and kinetics of a golf swing as performed by 84 male and one female amateur subjects of various skill levels. The analysis was performed using a variable full-body computer model of a human coupled with a flexible model of a golf club. Data to drive the model was obtained from subject swings recorded using a multi-camera motion analysis system. Model output included club trajectories, golfer/club interaction forces and torques, work and power, and club deflections. These data formed the basis for a statistical analysis of all subjects, and a detailed analysis and comparison of the swing characteristics of four of the subjects. The analysis generated much new data concerning the mechanics of the golf swing. It revealed that a golf swing is a highly coordinated and individual motion and subject-to-subject variations were significant. The study highlighted the importance of the wrists in generating club head velocity and orienting the club face. The trajectory of the hands and the ability to do work were the factors most closely related to skill level. Key PointsFull-body model of the golf swing.Mechanical description of the golf swing.Statistical analysis of golf swing mechanics.Comparisons of subject swing mechanics.
Agresta, Cristine; Ward, Christian R; Wright, W Geoffrey; Tucker, Carole A
2018-06-01
Many field sports involve equipment that restricts one or both arms from moving while running. Arm swing during running has been examined from a biomechanical and physiologic perspective but not from an injury perspective. Moreover, only bilateral arm swing suppression has been studied with respect to running. The purpose of this study was to determine the influence of running with one arm restrained on lower extremity mechanics associated with running or sport-related injury. Fifteen healthy participants ran at a self-selected speed with typical arm swing, with one arm restrained and with both arms restrained. Lower extremity kinematics and spatiotemporal measures were analysed for all arm swing conditions. Running with one arm restrained resulted in increased frontal plane knee and hip angles, decreased foot strike angle, and decreased centre of mass vertical displacement compared to typical arm swing or bilateral arm swing restriction. Stride length was decreased and step frequency increased when running with one or both arms restrained. Unilateral arm swing restriction induces changes in lower extremity kinematics that are not similar to running with bilateral arm swing restriction or typical arm swing motion. Running with one arm restrained increases frontal plane mechanics associated with risk of knee injury.
Smith, Aimée C; Roberts, Jonathan R; Wallace, Eric S; Kong, Pui; Forrester, Stephanie E
2016-02-01
Two-dimensional methods have been used to compute trunk kinematic variables (flexion/extension, lateral bend, axial rotation) and X-factor (difference in axial rotation between trunk and pelvis) during the golf swing. Recent X-factor studies advocated three-dimensional (3D) analysis due to the errors associated with two-dimensional (2D) methods, but this has not been investigated for all trunk kinematic variables. The purpose of this study was to compare trunk kinematic variables and X-factor calculated by 2D and 3D methods to examine how different approaches influenced their profiles during the swing. Trunk kinematic variables and X-factor were calculated for golfers from vectors projected onto the global laboratory planes and from 3D segment angles. Trunk kinematic variable profiles were similar in shape; however, there were statistically significant differences in trunk flexion (-6.5 ± 3.6°) at top of backswing and trunk right-side lateral bend (8.7 ± 2.9°) at impact. Differences between 2D and 3D X-factor (approximately 16°) could largely be explained by projection errors introduced to the 2D analysis through flexion and lateral bend of the trunk and pelvis segments. The results support the need to use a 3D method for kinematic data calculation to accurately analyze the golf swing.
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Fox, Dennis S.; Miller, Robert A.
2002-01-01
The development of the pulse detonation engine (PDE) requires robust design of the engine components that are capable of enduring harsh detonation environments. In this study, a high cycle thermal fatigue test rig was developed for evaluating candidate PDE combustor materials using a CO2 laser. The high cycle thermal fatigue behavior of Haynes 188 alloy was investigated under an enhanced pulsed laser test condition of 30 Hz cycle frequency (33 ms pulse period, and 10 ms pulse width including 0.2 ms pulse spike). The temperature swings generated by the laser pulses near the specimen surface were characterized by using one-dimensional finite difference modeling combined with experimental measurements. The temperature swings resulted in significant thermal cyclic stresses in the oxide scale/alloy system, and induced extensive surface cracking. Striations of various sizes were observed at the cracked surfaces and oxide/alloy interfaces under the cyclic stresses. The test results indicated that oxidation and creep-enhanced fatigue at the oxide scale/alloy interface was an important mechanism for the surface crack initiation and propagation under the simulated PDE condition.
Portable Cathode-Air Vapor-Feed Electrochemical Medical Oxygen Concentrator (OC)
NASA Technical Reports Server (NTRS)
Balasubramanian, Ashwin
2015-01-01
Missions on the International Space Station and future space exploration will present significant challenges to crew health care capabilities, particularly in the efficient utilization of onboard oxygen resources. Exploration vehicles will require lightweight, compact, and portable oxygen concentrators that can provide medical-grade oxygen from the ambient cabin air. Current pressure-swing adsorption OCs are heavy and bulky, require significant start-up periods, operate in narrow temperature ranges, and require a liquid water feed. Lynntech, Inc., has developed an electrochemical OC that operates with a cathode-air vapor feed, eliminating the need for a bulky onboard water supply. Lynntech's OC is smaller and lighter than conventional pressure-swing OCs, is capable of instant start-up, and operates over a temperature range of 5-80 C. Accomplished through a unique nanocomposite proton exchange membrane and catalyst technology, the unit delivers 4 standard liters per minute of humidified oxygen at 60 percent concentration. The technology enables both ambient-pressure operating devices for portable applications and pressurized (up to 3,600 psi) OC devices for stationary applications.
NASA Technical Reports Server (NTRS)
Mulloth, Lila M.; Rosen, Micha; Affleck, David; LeVan, M. Douglas; Wang, Yuan
2005-01-01
The air revitalization system of the International Space Station (ISS) operates in an open loop mode and relies on the resupply of oxygen and other consumables from earth for the life support of astronauts. A compressor is required for delivering the carbon dioxide from a removal assembly to a reduction unit to recover oxygen and thereby dosing the air-loop. We have developed a temperature-swing adsorption compressor (TSAC) that is energy efficient, quiet, and has no rapidly moving parts for performing these tasks. The TSAC is a solid-state compressor that has the capability to remove CO2 from a low- pressure source, and subsequently store, compress, and deliver at a higher pressure as required by a processor. The TSAC is an ideal interface device for CO2 removal and reduction units in the air revitalization loop of a spacecraft for oxygen recovery. This paper discusses the design and testing of a TSAC for carbon dioxide that has application in the ISS and future spacecraft for closing the air revitalization loop.
Yoshida, Keiichiro; Kuwahara, Takuya; Kuroki, Tomoyuki; Okubo, Masaaki
2012-09-15
NO(x) emitted from a stationary diesel engine generator was treated with a hybrid system comprising NO(x) reduction by nonthermal plasma (NTP) and temperature swing adsorption (TSA) driven by engine waste heat. TSA produces a low-volume gas mixture of N(2) and highly concentrated NO(x), which is effectively reduced by NTP treatment. Improved treatment performance and efficiency are achieved by re-injecting the NTP-treated gas mixture into the engine intake. The system comprises two switchable adsorption chambers; the operation of this system was simulated by using a one-chamber system. The maximum energy efficiency for NO(x) treatment is 200 g(NO(2))/kWh. The respective contributions of NTP and injection of N(2) and NO(x) to the performance were theoretically analyzed. The analysis predicts that high energy efficiency and high NO(x)-removal efficiency can be simultaneously achieved with this system but miniaturization of the adsorption chambers will be a challenge. Copyright © 2012 Elsevier B.V. All rights reserved.
A Three-Dimensional Kinematic and Kinetic Study of the College-Level Female Softball Swing
Milanovich, Monica; Nesbit, Steven M.
2014-01-01
This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings. Key Points The female softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. The paths of the grip point, bat centre-of-curvature, CG, and COP are complex yet reveal consistent patterns among subjects indicating that these patterns are fundamental components of the swing. The most important mechanical quantity relative to generating bat speed is the total work applied to the bat from the batter. Computer modeling of the softball swing is a viable means for study of the fundamental mechanics of the swing motion, the interactions between the batter and the bat, and the energy transfers between the two. PMID:24570623
A three-dimensional kinematic and kinetic study of the college-level female softball swing.
Milanovich, Monica; Nesbit, Steven M
2014-01-01
This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings. Key PointsThe female softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities.The paths of the grip point, bat centre-of-curvature, CG, and COP are complex yet reveal consistent patterns among subjects indicating that these patterns are fundamental components of the swing.The most important mechanical quantity relative to generating bat speed is the total work applied to the bat from the batter.Computer modeling of the softball swing is a viable means for study of the fundamental mechanics of the swing motion, the interactions between the batter and the bat, and the energy transfers between the two.
Evaluation of Silicon-on-Insulator HTOP-01 Operational Amplifier for Wide Temperature Operation
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad; Elbuluk, Malik
2008-01-01
Electronics capable of operation under extreme temperatures are required in many of NASA space exploration missions. Aerospace and military applications, as well as some terrestrial industries constitute environments where electronic systems are anticipated to be exposed to extreme temperatures and wide-range thermal swings. Electronics that are able to withstand and operate efficiently in such harsh environments would simplify, if not eliminate, traditional thermal control elements and their associated structures for proper ambient operation. As a result, overall system mass would be reduced, design would be simplified, and reliability would be improved. Electronic parts that are built utilizing silicon-on-insulator (SOI) technology are known to offer better radiation-tolerance compared to their conventional silicon counterparts, provide faster switching, and consume less power. They also exhibit reduced leakage current and, thus, they are often tailored for high temperature operation. These attributes make SOI-based devices suitable for use in harsh environments where extreme temperatures and wide thermal swings are anticipated. A new operational amplifier, based on silicon-on-insulator technology and geared for high temperature well-logging applications, was recently introduced by Honeywell Corporation. This HTOP-01 dual precision operational amplifier is a low power device, operates on a single supply, and has an internal oscillator and an external clocking option [1]. It is rated for operation from -55 C to +225 C with a maximum output current capability of 50 mA. The amplifier chip is designed as a 14-pin, hermetically-sealed device in a ceramic package. Table I shows some of the device manufacturer s specifications.
Development of Active Rocking Chair with Changing Swing According to Heartbeat Fluctuation
NASA Astrophysics Data System (ADS)
Kawashima, Takeshi
The purpose of this study is to realize a comfortable swing according to the condition of each individual person. A simple active rocking chair is developed, the swing of which changes with the heartbeat fluctuation of the seated person. The active rocking chair is driven by a solenoid for safety and silence. Swinging is strengthened when the period of the heartbeat lengthens, and it is weakened when the period shortens. Swinging is evaluated using a questionnaire of 16 bipolar scales that was developed for the evaluation of comfortable swinging on the basis of the semantic differential (SD) technique. As a result, it is confirmed that comfortable swinging is realized by the developed active rocking chair. Then the acceleration near the ear of the seated person is measured in order to examine the features of comfortable swinging using the feedback of heartbeat fluctuation. It is clarified that the power spectrum of the envelope of the acceleration waveform shows “1/f fluctuation”.
NASA Technical Reports Server (NTRS)
Iacomini, Christine; Powers, Aaron; Bower, Chad; Straub-Lopez, Kathrine; Anderson, Grant; MacCallum, Taber; Paul, Heather L.
2007-01-01
Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of carbon dioxide (CO2) in an environment with a CO2 partial pressure (ppCO2) of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (195K) removes metabolically-produced CO2 in the ventilation loop. Once fully loaded, the adsorbent is then warmed externally by the ventilation loop (300K), rejecting the captured CO2 to Mars ambient. Two beds are used to provide a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the ventilation loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available on Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments were conducted which lead to the selection and partial characterization of an appropriate adsorbent. The Molsiv Adsorbents 13X 8x12 (also known as NaX zeolite) successfully removed CO2 from a simulated ventilation loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design challenges as listed in the conclusions section of this paper.
M-H characteristics and demagnetization resistance of samarium-cobalt permanent magnets to 300 C
NASA Technical Reports Server (NTRS)
Niedra, Janis M.
1992-01-01
The influence of temperature on the M-H demagnetization characteristics of permanent magnets is important information for the full utilization of the capabilities of samarium-cobalt magnets at high temperatures in demagnetization-resistant permanent magnet devices. In high temperature space power converters, such as free-piston Stirling engine driven linear alternators, magnet demagnetization can occur as a long-term consequence of thermal agitation of domains and of metallurgical change, and also as an immediate consequence of too large an applied field. Investigated here is the short-term demagnetization resistance to applied fields derived from basic M-H data. This quasistatic demagnetization data was obtained for commercial, high-intrinsic-coercivity, Sm2Co17-type magnets from 5 sources, in the temperature range 23 to 300 C. An electromagnet driven, electronic hysteresigraph was used to test the 1-cm cubic samples. The observed variation of the 2nd quadrant M-H characteristics was a typical rapid loss of M-coercivity and a relatively lesser loss of remanence with increasing temperature. The 2nd quadrant M-H curve knee point is used to define the limits of operation safe against irreversible demagnetization due to an excessive bucking field for a given flux density swing at temperature. Such safe operating area plots are shown to differentiate the high temperature capabilities of the samples from different sources. For most of the samples, their 2nd quadrant M-H loop squareness increased with temperature, reaching a peak or a plateau above 250 C.
NASA Astrophysics Data System (ADS)
Smith, Samuel; Llinas, Juan-Pablo; Bokor, Jeffrey; Salahuddin, Sayeef
2018-01-01
Ballistic quantum transport calculations based on the non-equilbrium Green's function formalism show that field-effect transistor devices made from chevron-type graphene nanoribbons (CGNRs) could exhibit negative differential resistance with peak-to-valley ratios in excess of 4800 at room temperature as well as steep-slope switching with 6 mV/decade subtheshold swing over five orders of magnitude and ON-currents of 88$\\mu$A/$\\mu$m. This is enabled by the superlattice-like structure of these ribbons that have large periodic unit cells with regions of different effective bandgap, resulting in minibands and gaps in the density of states above the conduction band edge. The CGNR ribbon used in our proposed device has been previously fabricated with bottom-up chemical synthesis techniques and could be incorporated into an experimentally-realizable structure.
NASA Astrophysics Data System (ADS)
Lin, Yu-Shu; Cheng, Po-Hsien; Huang, Kuei-Wen; Lin, Hsin-Chih; Chen, Miin-Jang
2018-06-01
Sub-10 nm high-K gate dielectrics are of critical importance in two-dimensional transition metal dichalcogenides (TMDs) transistors. However, the chemical inertness of TMDs gives rise to a lot of pinholes in gate dielectrics, resulting in large gate leakage current. In this study, sub-10 nm, uniform and pinhole-free Al2O3 high-K gate dielectrics on MoS2 were achieved by atomic layer deposition without surface functionalization, in which an ultrathin Al2O3 layer prepared with a short purge time at a low temperature of 80 °C offers the nucleation cites for the deposition of the overlaying oxide at a higher temperature. Conductive atomic force microscopy reveals the significant suppression of gate leakage current in the sub-10 nm Al2O3 gate dielectrics with the low-temperature nucleation layer. Raman and X-ray photoelectron spectroscopies indicate that no oxidation occurred during the deposition of the low-temperature Al2O3 nucleation layer on MoS2. With the high-quality sub-10 nm Al2O3 high-K gate dielectrics, low hysteresis and subthreshold swing were demonstrated on the normally-off top-gated MoS2 transistors.
van der Giesen, Coen; Meinrenken, Christoph J; Kleijn, René; Sprecher, Benjamin; Lackner, Klaus S; Kramer, Gert Jan
2017-01-17
Most carbon capture and storage (CCS) envisions capturing CO 2 from flue gas. Direct air capture (DAC) of CO 2 has hitherto been deemed unviable because of the higher energy associated with capture at low atmospheric concentrations. We present a Life Cycle Assessment of coal-fired electricity generation that compares monoethanolamine (MEA)-based postcombustion capture (PCC) of CO 2 with distributed, humidity-swing-based direct air capture (HS-DAC). Given suitable temperature, humidity, wind, and water availability, HS-DAC can be largely passive. Comparing energy requirements of HS-DAC and MEA-PCC, we find that the parasitic load of HS-DAC is less than twice that of MEA-PCC (60-72 kJ/mol versus 33-46 kJ/mol, respectively). We also compare other environmental impacts as a function of net greenhouse gas (GHG) mitigation: To achieve the same 73% mitigation as MEA-PCC, HS-DAC would increase nine other environmental impacts by on average 38%, whereas MEA-PCC would increase them by 31%. Powering distributed HS-DAC with photovoltaics (instead of coal) while including recapture of all background GHG, reduces this increase to 18%, hypothetically enabling coal-based electricity with net-zero life-cycle GHG. We conclude that, in suitable geographies, HS-DAC can complement MEA-PCC to enable CO 2 capture independent of time and location of emissions and recapture background GHG from fossil-based electricity beyond flue stack emissions.
The effect of spin in swing bowling in cricket: model trajectories for spin alone
NASA Astrophysics Data System (ADS)
Robinson, Garry; Robinson, Ian
2015-02-01
In ‘swing’ bowling, as employed by fast and fast-medium bowlers in cricket, back-spin along the line of the seam is normally applied in order to keep the seam vertical and to provide stability against ‘wobble’ of the seam. Whilst spin is normally thought of as primarily being the slow bowler's domain, the spin applied by the swing bowler has the side-effect of generating a lift or Magnus force. This force, depending on the orientation of the seam and hence that of the back-spin, can have a side-ways component as well as the expected vertical ‘lift’ component. The effect of the spin itself, in influencing the trajectory of the fast bowler's delivery, is normally not considered, presumably being thought of as negligible. The purpose of this paper is to investigate, using calculated model trajectories, the amount of side-ways movement due to the spin and to see how this predicted movement compares with the total observed side-ways movement. The size of the vertical lift component is also estimated. It is found that, although the spin is an essential part of the successful swing bowler's delivery, the amount of side-ways movement due to the spin itself amounts to a few centimetres or so, and is therefore small, but perhaps not negligible, compared to the total amount of side-ways movement observed. The spin does, however, provide a considerable amount of lift compared to the equivalent delivery bowled without spin, altering the point of pitching by up to 3 m, a very large amount indeed. Thus, for example, bowling a ball with the seam pointing directly down the pitch and not designed to swing side-ways at all, but with the amount of back-spin varied, could provide a very powerful additional weapon in the fast bowler's arsenal. So-called ‘sling bowlers’, who use a very low arm action, can take advantage of spin since effectively they can apply side-spin to the ball, giving rise to a large side-ways movement, ˜ 20{}^\\circ cm or more, which certainly is significant. For a given amount of spin the amount of side-ways movement increases as the bowler's delivery arm becomes more horizontal. This technique could also be exploited by normal spin bowlers as well as swing bowlers.
33 CFR 118.70 - Lights on swing bridges.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Lights on swing bridges. 118.70 Section 118.70 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.70 Lights on swing bridges. (a) Swing span lights on through bridges. Each...
Brain networks governing the golf swing in professional golfers.
Kim, Jin Hyun; Han, Joung Kyue; Kim, Bung-Nyun; Han, Doug Hyun
2015-01-01
Golf, as with most complex motor skills, requires multiple different brain functions, including attention, motor planning, coordination, calculation of timing, and emotional control. In this study we assessed the correlation between swing components and brain connectivity from the cerebellum to the cerebrum. Ten female golf players and 10 age-matched female controls were recruited. In order to determine swing consistency among participants, the standard deviation (SD) of the mean swing speed time and the SD of the mean swing angle were assessed over 30 swings. Functional brain connectivity was assessed by resting state functional MRI. Pro-golfers showed greater positive left cerebellum connectivity to the occipital lobe, temporal lobe, parietal lobe and both frontal lobes compared to controls. The SD of play scores was positively correlated with the SD of the impact angle. Constant swing speed and back swing angle in professional golfers were associated with functional connectivity (FC) between the cerebellum and parietal and frontal lobes. In addition, the constant impact angle in professional golfers was associated with improved golf scores and additional FC of the thalamus.
Göpfert, Caroline; Lindinger, Stefan J; Ohtonen, Olli; Rapp, Walter; Müller, Erich; Linnamo, Vesa
2016-06-01
The study investigated the effects of arm swing during leg push-off in V2-alternate/G4 skating on neuromuscular activation and force production by the leg muscles. Nine skilled cross-country skiers performed V2-alternate skating without poles at moderate, high, and maximal speeds, both with free (SWING) and restricted arm swing (NOSWING). Maximal speed was 5% greater in SWING (P<0.01), while neuromuscular activation and produced forces did not differ between techniques. At both moderate and high speed the maximal (2% and 5%, respectively) and average (both 5%) vertical force and associated impulse (10% and 14%) were greater with SWING (all P<0.05). At high speed range of motion and angular velocity of knee flexion were 24% greater with SWING (both P<0.05), while average EMG of m. biceps femoris was 31% lower (all P<0.05) in SWING. In a similar manner, the average EMG of m. vastus medialis and m. biceps femoris were lower (17% and 32%, P<0.05) during the following knee extension. Thus, swinging the arms while performing V2-alternate can enhance both maximal speed and skiing economy at moderate and, in particularly, high speeds. Copyright © 2016 Elsevier B.V. All rights reserved.
A springy pendulum could describe the swing leg kinetics of human walking.
Song, Hyunggwi; Park, Heewon; Park, Sukyung
2016-06-14
The dynamics of human walking during various walking conditions could be qualitatively captured by the springy legged dynamics, which have been used as a theoretical framework for bipedal robotics applications. However, the spring-loaded inverted pendulum model describes the motion of the center of mass (CoM), which combines the torso, swing and stance legs together and does not explicitly inform us as to whether the inter-limb dynamics share the springy legged dynamics characteristics of the CoM. In this study, we examined whether the swing leg dynamics could also be represented by springy mechanics and whether the swing leg stiffness shows a dependence on gait speed, as has been observed in CoM mechanics during walking. The swing leg was modeled as a spring-loaded pendulum hinged at the hip joint, which is under forward motion. The model parameters of the loaded mass were adopted from body parameters and anthropometric tables, whereas the free model parameters for the rest length of the spring and its stiffness were estimated to best match the data for the swing leg joint forces. The joint forces of the swing leg were well represented by the springy pendulum model at various walking speeds with a regression coefficient of R(2)>0.8. The swing leg stiffness increased with walking speed and was correlated with the swing frequency, which is consistent with previous observations from CoM dynamics described using the compliant leg. These results suggest that the swing leg also shares the springy dynamics, and the compliant walking model could be extended to better present swing leg dynamics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Delabastita, Tijs; Desloovere, Kaat; Meyns, Pieter
2016-01-01
Observational research suggests that in children with cerebral palsy, the altered arm swing is linked to instability during walking. Therefore, the current study investigates whether children with cerebral palsy use their arms more than typically developing children, to enhance gait stability. Evidence also suggests an influence of walking speed on gait stability. Moreover, previous research highlighted a link between walking speed and arm swing. Hence, the experiment aimed to explore differences between typically developing children and children with cerebral palsy taking into account the combined influence of restricting arm swing and increasing walking speed on gait stability. Spatiotemporal gait characteristics, trunk movement parameters and margins of stability were obtained using three dimensional gait analysis to assess gait stability of 26 children with cerebral palsy and 24 typically developing children. Four walking conditions were evaluated: (i) free arm swing and preferred walking speed; (ii) restricted arm swing and preferred walking speed; (iii) free arm swing and high walking speed; and (iv) restricted arm swing and high walking speed. Double support time and trunk acceleration variability increased more when arm swing was restricted in children with bilateral cerebral palsy compared to typically developing children and children with unilateral cerebral palsy. Trunk sway velocity increased more when walking speed was increased in children with unilateral cerebral palsy compared to children with bilateral cerebral palsy and typically developing children and in children with bilateral cerebral palsy compared to typically developing children. Trunk sway velocity increased more when both arm swing was restricted and walking speed was increased in children with bilateral cerebral palsy compared to typically developing children. It is proposed that facilitating arm swing during gait rehabilitation can improve gait stability and decrease trunk movements in children with cerebral palsy. The current results thereby partly support the suggestion that facilitating arm swing in specific situations possibly enhances safety and reduces the risk of falling in children with cerebral palsy. PMID:27471457
Large Swing Valve in the 10- by 10-Foot Supersonic Wind Tunnel
1956-05-21
A 24-foot diameter swing valve is seen in an open position inside the new 10- by 10-Foot Supersonic Wind Tunnel at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The 10- by 10 was the most powerful propulsion wind tunnel in the nation. After over three years of construction the tunnel was ready to conduct its first tests in early 1956. The 10- by 10-foot tunnel was part of Congress’ Unitary Plan Act which coordinated wind tunnel construction at the NACA, Air Force, industry, and universities. The 10- by 10 was the largest of the three NACA tunnels built under the act. This large swinging valve is critical to the operation of the facility. In one position the valve seals off the tunnel exhaust, making the tunnel a closed circuit, which is used for aerodynamic testing of models. In its other position, the valve acts as a seal across the tunnel and leaves the tunnel exhaust open. This arrangement is used when engines are fired. The air going through the tunnel is taken from the atmosphere and returned to the atmosphere after one pass through the tunnel. Engines up to five feet in diameter can be tested in the 10- by 10-foot test section. Air flows up to Mach 3.5 can be fed through the test section by a 250,000-horsepower axial-flow compressor fan. The incoming air must be dehumidified and cooled so that the proper conditions are present for the test. A large air dryer with 1,890 tons of activated alumina soaks up 1.5 tons of water per minute from the air flow. A cooling apparatus equivalent to 250,000 household air conditioners is used to cool the air.
The impact of model detail on power grid resilience measures
NASA Astrophysics Data System (ADS)
Auer, S.; Kleis, K.; Schultz, P.; Kurths, J.; Hellmann, F.
2016-05-01
Extreme events are a challenge to natural as well as man-made systems. For critical infrastructure like power grids, we need to understand their resilience against large disturbances. Recently, new measures of the resilience of dynamical systems have been developed in the complex system literature. Basin stability and survivability respectively assess the asymptotic and transient behavior of a system when subjected to arbitrary, localized but large perturbations in frequency and phase. To employ these methods that assess power grid resilience, we need to choose a certain model detail of the power grid. For the grid topology we considered the Scandinavian grid and an ensemble of power grids generated with a random growth model. So far the most popular model that has been studied is the classical swing equation model for the frequency response of generators and motors. In this paper we study a more sophisticated model of synchronous machines that also takes voltage dynamics into account, and compare it to the previously studied model. This model has been found to give an accurate picture of the long term evolution of synchronous machines in the engineering literature for post fault studies. We find evidence that some stable fix points of the swing equation become unstable when we add voltage dynamics. If this occurs the asymptotic behavior of the system can be dramatically altered, and basin stability estimates obtained with the swing equation can be dramatically wrong. We also find that the survivability does not change significantly when taking the voltage dynamics into account. Further, the limit cycle type asymptotic behaviour is strongly correlated with transient voltages that violate typical operational voltage bounds. Thus, transient voltage bounds are dominated by transient frequency bounds and play no large role for realistic parameters.
Dynamic motion of red blood cells in simple shear flow
NASA Astrophysics Data System (ADS)
Sui, Y.; Chew, Y. T.; Roy, P.; Cheng, Y. P.; Low, H. T.
2008-11-01
A three-dimensional numerical model is proposed to simulate the dynamic motion of red blood cells (RBCs) in simple shear flow. The RBCs are approximated by ghost cells consisting of Newtonian liquid drops enclosed by Skalak membranes which take into account the membrane shear elasticity and the membrane area incompressibility. The RBCs have an initially biconcave discoid resting shape, and the internal liquid is assumed to have the same physical properties as the matrix fluid. The simulation is based on a hybrid method, in which the immersed boundary concept is introduced into the framework of the lattice Boltzmann method, and a finite element model is incorporated to obtain the forces acting on the nodes of the cell membrane which is discretized into flat triangular elements. The dynamic motion of RBCs is investigated in simple shear flow under a broad range of shear rates. At large shear rates, the cells are found to carry out a swinging motion, in which periodic inclination oscillation and shape deformation superimpose on the membrane tank treading motion. With the shear rate decreasing, the swinging amplitude of the cell increases, and finally triggers a transition to tumbling motion. This is the first direct numerical simulation that predicts both the swinging motion of the RBCs and the shear rate induced transition, which have been observed in a recent experiment. It is also found that as the mode changes from swinging to tumbling, the apparent viscosity of the suspension increases monotonically.
Return to Golf Following Left Total Hip Arthroplasty in a Golfer Who is Right Handed
Betlach, Michael; Senkarik, Ryan; Smith, Robyn; Voight, Michael
2007-01-01
Background Research indicates return to golf is a safe activity following total hip arthroplasty (THA). Frequently, individuals have shown both physical faults and swing faults after THA, which can persist even following rehabilitation. Physical limitations and pain often lead to faults in the golfers swing, most notably “hanging back.” These problems may not be improved after surgery unless the proper re-training takes place. Objectives Using pre-surgical as well as post-surgical information, physical faults and swing faults were identified. A corrective training protocol was developed to normalize physical and swing limitations. Case description The patient is a 52-year old male golfer who underwent left total hip arthroplasty secondary to left hip osteoarthritis. Video analysis both pre and post surgery indicated the patient was “hanging back.” This “hanging back” can lead to an inefficient golf swing and potential injury. Following a physical evaluation, a training protocol was designed to correct abnormal physical findings to assist the patient in creating an efficient golf swing. Outcomes The patient was able to swing the golf club with proper weighting of the lead lower extremity, significant improvement of swing efficiency, and return to play at a zero handicap following a corrective training protocol. Discussion A return to full weight bearing, functional strength, range of motion, stability, and balance are critical to regaining the physical skills necessary to properly swing the golf club. Further, mastery of these objective components lend themselves to the trust needed to load the lead leg with confidence during the golf swing. PMID:21509144
Work and power analysis of the golf swing.
Nesbit, Steven M; Serrano, Monika
2005-12-01
A work and power (energy) analysis of the golf swing is presented as a method for evaluating the mechanics of the golf swing. Two computer models were used to estimate the energy production, transfers, and conversions within the body and the golf club by employing standard methods of mechanics to calculate work of forces and torques, kinetic energies, strain energies, and power during the golf swing. A detailed model of the golf club determined the energy transfers and conversions within the club during the downswing. A full-body computer model of the golfer determined the internal work produced at the body joints during the downswing. Four diverse amateur subjects were analyzed and compared using these two models. The energy approach yielded new information on swing mechanics, determined the force and torque components that accelerated the club, illustrated which segments of the body produced work, determined the timing of internal work generation, measured swing efficiencies, calculated shaft energy storage and release, and proved that forces and range of motion were equally important in developing club head velocity. A more comprehensive description of the downswing emerged from information derived from an energy based analysis. Key PointsFull-Body Model of the golf swing.Energy analysis of the golf swing.Work of the body joints dDuring the golf swing.Comparisons of subject work and power characteristics.
Work and Power Analysis of the Golf Swing
Nesbit, Steven M.; Serrano, Monika
2005-01-01
A work and power (energy) analysis of the golf swing is presented as a method for evaluating the mechanics of the golf swing. Two computer models were used to estimate the energy production, transfers, and conversions within the body and the golf club by employing standard methods of mechanics to calculate work of forces and torques, kinetic energies, strain energies, and power during the golf swing. A detailed model of the golf club determined the energy transfers and conversions within the club during the downswing. A full-body computer model of the golfer determined the internal work produced at the body joints during the downswing. Four diverse amateur subjects were analyzed and compared using these two models. The energy approach yielded new information on swing mechanics, determined the force and torque components that accelerated the club, illustrated which segments of the body produced work, determined the timing of internal work generation, measured swing efficiencies, calculated shaft energy storage and release, and proved that forces and range of motion were equally important in developing club head velocity. A more comprehensive description of the downswing emerged from information derived from an energy based analysis. Key Points Full-Body Model of the golf swing. Energy analysis of the golf swing. Work of the body joints dDuring the golf swing. Comparisons of subject work and power characteristics. PMID:24627666
Hejrati, Babak; Chesebrough, Sam; Bo Foreman, K; Abbott, Jake J; Merryweather, Andrew S
2016-10-01
Previous studies have shown that inclusion of arm swing in gait rehabilitation leads to more effective walking recovery in patients with walking impairments. However, little is known about the correct arm-swing trajectories to be used in gait rehabilitation given the fact that changes in walking conditions affect arm-swing patterns. In this paper we present a comprehensive look at the effects of a variety of conditions on arm-swing patterns during walking. The results describe the effects of surface slope, walking speed, and physical characteristics on arm-swing patterns in healthy individuals. We propose data-driven mathematical models to describe arm-swing trajectories. Thirty individuals (fifteen females and fifteen males) with a wide range of height (1.58-1.91m) and body mass (49-98kg), participated in our study. Based on their self-selected walking speed, each participant performed walking trials with four speeds on five surface slopes while their whole-body kinematics were recorded. Statistical analysis showed that walking speed, surface slope, and height were the major factors influencing arm swing during locomotion. The results demonstrate that data-driven models can successfully describe arm-swing trajectories for normal gait under varying walking conditions. The findings also provide insight into the behavior of the elbow during walking. Copyright © 2016. Published by Elsevier B.V.
Mazumdar, Atmadeep; Sen, Krishna Nirmalya; Lahiri, Balendra Nath
2007-01-01
The Haddon matrix is a potential tool for recognizing hazards in any operating engineering system. This paper presents a case study of operational hazards at a large construction site. The fish bone structure helps to visualize and relate the chain of events, which led to the failure of the system. The two-tier Haddon matrix approach helps to analyze the problem and subsequently prescribes preventive steps. The cybernetic approach has been undertaken to establish the relationship among event variables and to identify the ones with most potential. Those event variables in this case study, based on the cybernetic concepts like control responsiveness and controllability salience, are (a) uncontrolled swing of sheet contributing to energy, (b) slippage of sheet from anchor, (c) restricted longitudinal and transverse swing or rotation about the suspension, (d) guilt or uncertainty of the crane driver, (e) safe working practices and environment.
Club position relative to the golfer's swing plane meaningfully affects swing dynamics.
MacKenzie, Sasho J
2012-06-01
Previous research indicates that the motion of the golf club is not planar and that the plane traced out by the club is different than that of the golfer's hands. The aim of the present study was to investigate how the position of the club, relative to the golfer's swing plane, influences the motion of the club by using a four-segment (torso, upper arm, forearm, and club), three-dimensional forward dynamics model. A genetic algorithm optimized the coordination of the model's four muscular torque generators to produce the best golf swings possible under six different conditions. The series of simulations were designed to demonstrate the effect of positioning the club above, and below, the golfer's swing plane as well as the effect of changing the steepness of the golfer's swing plane. The simulation results suggest that positioning the club below the golfer's swing plane, early in the downswing, will facilitate the squaring of the clubface for impact, while positioning the club above the plane will have the opposite effect. It was also demonstrated that changing the steepness of the golfer's swing plane by 10 degrees can have little effect on the delivery of the clubhead to the ball.
Swings and roundabouts: management of jealousy in heterosexual swinging couples.
de Visser, Richard; McDonald, Dee
2007-06-01
Swinging involves consensual mutual involvement in extra-dyadic sex. Jealousy in swinging couples is an interesting topic for social psychological research, because it is a common and acceptable response to a romantic partner's real or imagined infidelity. This qualitative study examined the management of jealousy among four active heterosexual swinging couples living in southern England. Participants highlighted the importance of discussion and negotiation to develop a shared couple identity and shared rules and boundaries that allowed them to manage jealousy so that they could better enjoy swinging. Rather than seeking to eliminate jealousy, swingers may manage their feelings of jealousy in order to increase sexual excitement and arousal. This study adds to our understanding of jealousy among swingers and the broader issue of jealousy in intimate relationships.
A review of oxygen removal from oxygen-bearing coal-mine methane.
Zhao, Peiyu; Zhang, Guojie; Sun, Yinghui; Xu, Ying
2017-06-01
In this article, a comparison will be made concerning the advantages and disadvantages of five kinds of coal mine methane (CMM) deoxygenation method, including pressure swing adsorption, combustion, membrane separation, non-metallic reduction, and cryogenic distillation. Pressure swing adsorption has a wide range of application and strong production capacity. To achieve this goal, adsorbent must have high selectivity, adsorption capacity, and adequate adsorption/desorption kinetics, remain stable after several adsorption/desorption cycles, and possess good thermal and mechanical stabilities. Catalytic combustion deoxygenation is a high-temperature exothermic redox chemical reaction, which releases large amounts of thermal energy. So, the stable and accurate control of the temperature is not easy. Meanwhile partial methane is lost. The key of catalytic combustion deoxygenation lies in the development of high-efficiency catalyst. Membrane separation has advantages of high separation efficiency and low energy consumption. However, there are many obstacles, including higher costs. Membrane materials have the requirements of both high permeability and high selectivity. The development of new membrane materials is a key for membrane separation. Cryogenic distillation has many excellence advantages, such as high purity production and high recovery. However, the energy consumption increases with decreasing CH 4 concentrations in feed gas. Moreover, there are many types of operational security problems. And that several kinds of deoxygenation techniques mentioned above have an economic value just for oxygen-bearing CMM with methane content above 30%. Moreover, all the above methods are not applicable to deoxygenation of low concentration CMM. Non-metallic reduction method cannot only realize cyclic utilization of deoxidizer but also have no impurity gases generation. It also has a relatively low cost and low loss rate of methane, and the oxygen is removed thoroughly. In particular, the non-metallic reduction method has good development prospects for low concentration oxygen-bearing CMM. This article also points out the direction of future development of coal mine methane deoxygenation.
NASA Technical Reports Server (NTRS)
Swickrath, Michael J.; Watts,Carly; Anderson, Molly; McMillin, Summer; Boerman, Craig; Colunga, Aaron; Vogel, Matthew
2011-01-01
Controlling carbon dioxide (CO2) and water (H2O) concentrations in the vapor phase of a space suit is critical to ensuring an astronauts safety, comfortability, and capability to perform extra-vehicular activity (EVA) tasks. Historically, this has been accomplished using lithium hydroxide (LiOH) and metal oxides (MetOx). Lithium hydroxide is a consumable material and requires priming with water before it becomes effective at removing carbon dioxide. MetOx is regenerable through a power-intensive thermal cycle but is significantly heavier on a volume basis than LiOH. As an alternative, amine-based vacuum swing beds are under aggressive development for EVA applications which control atmospheric concentrations of both CO2 and H2O through a fully-regenerative process. The current concept, referred to as the rapid cycle amine (RCA), has resulted in numerous laboratory prototypes. Performance of these prototypes have been assessed and documented from experimental and theoretical perspectives. To support developmental efforts, a first principles model has also been established for the vacuum swing adsorption technology. The efforts documented herein summarize performance characterization and simulation results for several variable metabolic profiles subjected to the RCA. Furthermore, a variety of control methods are explored including timed swing cycles, instantaneous CO2 feedback control, and time-averaged CO2 feedback control. A variety of off-nominal tests are also explored including high/low suit temperatures, increasingly high humidity cases, and dynamic pressure cases simulating the suit pre-breathe protocol. Consequently, this work builds on efforts previous efforts to fully bound the performance of the rapid cycle amine under a variety of nominal and off-nominal conditions.
Effects of Aging on Arm Swing during Gait: The Role of Gait Speed and Dual Tasking.
Mirelman, Anat; Bernad-Elazari, Hagar; Nobel, Tomer; Thaler, Avner; Peruzzi, Agnese; Plotnik, Meir; Giladi, Nir; Hausdorff, Jeffrey M
2015-01-01
Healthy walking is characterized by pronounced arm swing and axial rotation. Aging effects on gait speed, stride length and stride time variability have been previously reported, however, less is known about aging effects on arm swing and axial rotation and their relationship to age-associated gait changes during usual walking and during more challenging conditions like dual tasking. Sixty healthy adults between the ages of 30-77 were included in this study designed to address this gap. Lightweight body fixed sensors were placed on each wrist and lower back. Participants walked under 3 walking conditions each of 1 minute: 1) comfortable speed, 2) walking while serially subtracting 3's (Dual Task), 3) walking at fast speed. Aging effects on arm swing amplitude, range, symmetry, jerk and axial rotation amplitude and jerk were compared between decades of age (30-40; 41-50; 51-60; 61-77 years). As expected, older adults walked slower (p = 0.03) and with increased stride variability (p = 0.02). Arm swing amplitude decreased with age under all conditions (p = 0.04). In the oldest group, arm swing decreased during dual task and increased during the fast walking condition (p<0.0001). Similarly, arm swing asymmetry increased during the dual task in the older groups (p<0.004), but not in the younger groups (p = 0.67). Significant differences between groups and within conditions were observed in arm swing jerk (p<0.02), axial rotation amplitude (p<0.02) and axial jerk (p<0.001). Gait speed, arm swing amplitude of the dominant arm, arm swing asymmetry and axial rotation jerk were all independent predictors of age in a multivariate model. These findings suggest that the effects of gait speed and dual tasking on arm swing and axial rotation during walking are altered among healthy older adults. Follow-up work is needed to examine if these effects contribute to reduced stability in aging.
Effects of Aging on Arm Swing during Gait: The Role of Gait Speed and Dual Tasking
Mirelman, Anat; Bernad-Elazari, Hagar; Nobel, Tomer; Thaler, Avner; Peruzzi, Agnese; Plotnik, Meir; Giladi, Nir; Hausdorff, Jeffrey M.
2015-01-01
Healthy walking is characterized by pronounced arm swing and axial rotation. Aging effects on gait speed, stride length and stride time variability have been previously reported, however, less is known about aging effects on arm swing and axial rotation and their relationship to age-associated gait changes during usual walking and during more challenging conditions like dual tasking. Sixty healthy adults between the ages of 30–77 were included in this study designed to address this gap. Lightweight body fixed sensors were placed on each wrist and lower back. Participants walked under 3 walking conditions each of 1 minute: 1) comfortable speed, 2) walking while serially subtracting 3’s (Dual Task), 3) walking at fast speed. Aging effects on arm swing amplitude, range, symmetry, jerk and axial rotation amplitude and jerk were compared between decades of age (30–40; 41–50; 51–60; 61–77 years). As expected, older adults walked slower (p = 0.03) and with increased stride variability (p = 0.02). Arm swing amplitude decreased with age under all conditions (p = 0.04). In the oldest group, arm swing decreased during dual task and increased during the fast walking condition (p<0.0001). Similarly, arm swing asymmetry increased during the dual task in the older groups (p<0.004), but not in the younger groups (p = 0.67). Significant differences between groups and within conditions were observed in arm swing jerk (p<0.02), axial rotation amplitude (p<0.02) and axial jerk (p<0.001). Gait speed, arm swing amplitude of the dominant arm, arm swing asymmetry and axial rotation jerk were all independent predictors of age in a multivariate model. These findings suggest that the effects of gait speed and dual tasking on arm swing and axial rotation during walking are altered among healthy older adults. Follow-up work is needed to examine if these effects contribute to reduced stability in aging. PMID:26305896
Evaluating the effects of under loaded and overloaded warm ups on subsequent swing velocity.
Miller, Ryan M; Heishman, Aaron D; Freitas, Eduardo D S; Bemben, Michael G
2017-08-26
Several attempts to identify the optimal on deck procedure to enhance swing velocity in baseball have been made. However, inconsistent findings continue to constitute much of the body of literature. Additionally, the emergence of athlete monitoring in sport has led to the exploration of more sport specific tasks to potentially identify athlete fatigue and readiness to perform. Therefore, the purpose of this investigation was to examine three different bat weight warm up protocols on subsequent swing velocity and to examine the reliability of swing velocity measurements to allude to its potential a sport specific athlete monitoring metric. Thirty-two recreational male baseball players 20.3 ± 2.0years, 179.6 ± 7.1cm and 89.6± 11.1kg completed the study. Subjects completed three testing visits that included warming up with a control bat ([CB] 32in, 29oz), plastic bat ([PB] 31in, 6.4oz), or heavy bat ([HB] 32in, 57oz). Testing visits began with three CB swing trials followed by three intervention bat trials, then concluded with three additional CB swings. Swing velocity was assessed using visual 3D technology. Analyses of variance indicate that following the PB (26.6 ± 2.0m/s) and CB interventions (26.2 ± 1.7m/s) significantly faster (p<0.001) swing velocities were generated when compared to the traditional HB intervention (24.1 ± 2.2m/s). When assessed for reliability, the average ICC was 0.681 and Chronbach's alpha was 0.95 indicating exceptional reliability. Congruent to previous research, this data bolsters the notion that warming up with a HB can hinder swing velocity. However, in contrast to previous research this data suggests that using a PB can increase swing velocity significantly. Furthermore, visual 3D can be designated as an exceptionally reliable device to measure swing velocity.
Alteration of swing leg work and power during human accelerated sprinting
Matsubayashi, Takeo; Matsuo, Akifumi; Zushi, Koji
2017-01-01
ABSTRACT This study investigated changes in lower-extremity joint work and power during the swing phase in a maximal accelerated sprinting. Twelve male sprinters performed 60 m maximal sprints while motion data was recorded. Lower-extremity joint work and power during the swing phase of each stride for both legs were calculated. Positive hip and negative knee work (≈4.3 and ≈−2.9 J kg−1) and mean power (≈13.4 and ≈−8.7 W kg−1) during the entire swing phase stabilized or decreased after the 26.2±1.1 (9.69±0.25 m s−1) or 34.3±1.5 m mark (9.97±0.26 m s−1) during the acceleration phase. In contrast, the hip negative work and mean power during the early swing phase (≈7-fold and ≈3.7-fold increase in total), as well as the knee negative work and power during the terminal swing phase (≈1.85-fold and ≈2-fold increase in total), increased until maximal speed. Moreover, only the magnitudes of increases in negative work and mean power at hip and knee joints during the swing phase were positively associated with the increment of running speed from the middle of acceleration phase. These findings indicate that the roles of energy generation and absorption at the hip and knee joints shift around the middle of the acceleration phase as energy generation and absorption at the hip during the late swing phase and at the knee during early swing phase are generally maintained or decreased, and negative work and power at hip during the early swing phase and at knee during the terminal swing phase may be responsible for increasing running speed when approaching maximal speed. PMID:28396485
Effects of training with a dynamic moment of inertia bat on swing performance.
Liu, Chiang; Liu, Ya-Chen; Kao, Ying-Chieh; Shiang, Tzyy-Yuang
2011-11-01
The purpose of this study was to investigate the effects of the 8-week dynamic moment of inertia (DMOI) bat training on swing velocity, batted-ball speed, hitting distance, muscle power, and grip force. The DMOI bat is characterized in that the bat could be swung more easily by reducing the moment of inertia at the initial stage of swing without decreasing the bat weight and has a faster swing velocity and lower muscle activity. Seventeen varsity baseball players were randomly assigned to the DMOI bat training group (n = 9) and the normal bat training group (n = 8). The training protocol was 7 swings each set, 5-8 sets each time, 3 times each week, and 8 weeks' training period. The results showed that the swing training with the DMOI bat for 8 weeks significantly increased swing velocity by about 6.20% (96.86 ± 8.48 vs. 102.82 ± 9.93 km·h(-1)), hitting distance by about 6.69% (80.06 ± 9.16 vs. 84.99 ± 7.26 m), muscle power of the right arm by about 12.04% (3.34 ± 0.41 vs. 3.74 ± 0.61 m), and muscle power of the left arm by about 8.23% (3.36 ± 0.46 vs. 3.61 ± 0.39 m) (p < 0.05). Furthermore, the DMOI bat training group had a significantly better change percentage in swing velocity, hitting distance, and grip force of the left hand than did the normal bat training group (p < 0.05). The findings suggested that the swing training with the DMOI bat has a positive benefit on swing performance and that the DMOI bat could be used as a new training tool in baseball.
Near-thermal limit gating in heavily doped III-V semiconductor nanowires using polymer electrolytes
NASA Astrophysics Data System (ADS)
Ullah, A. R.; Carrad, D. J.; Krogstrup, P.; Nygârd, J.; Micolich, A. P.
2018-02-01
Doping is a common route to reducing nanowire transistor on-resistance but it has limits. A high doping level gives significant loss in gate performance and ultimately complete gate failure. We show that electrolyte gating remains effective even when the Be doping in our GaAs nanowires is so high that traditional metal-oxide gates fail. In this regime we obtain a combination of subthreshold swing and contact resistance that surpasses the best existing p -type nanowire metal-oxide semiconductor field-effect transistors (MOSFETs). Our subthreshold swing of 75 mV/dec is within 25 % of the room-temperature thermal limit and comparable with n -InP and n -GaAs nanowire MOSFETs. Our results open a new path to extending the performance and application of nanowire transistors, and motivate further work on improved solid electrolytes for nanoscale device applications.
NASA Astrophysics Data System (ADS)
Zhang, Q.; Shan, F. K.; Liu, G. X.; Liu, A.; Lee, W. J.; Shin, B. C.
2014-05-01
Amorphous indium-titanium-zinc-oxide (ITZO) thin-film transistors (TFTs) with various channel thicknesses were fabricated at room temperature by using pulsed laser deposition. The channel layer thickness (CLT) dependence of the TFTs was investigated. All the ITZO thin films were amorphous, and the surface roughnesses decreased slightly first and then increased with increasing CLT. With increasing CLT from 35 to 140 nm, the on/off current ratio and the field-effect mobility increased, and the subthreshold swing decreased. The TFT with a CLT of 210 nm exhibited the worst performance, while the ITZO TFT with a CLT of 140 nm exhibited the best performance with a subthreshold voltage of 2.86 V, a mobility of 53.9 cm2V-1s-1, a subthreshold swing of 0.29 V/decade and an on/off current ratio of 109.
XRF inductive bead fusion and PLC based control system
NASA Astrophysics Data System (ADS)
Zhu, Jin-hong; Wang, Ying-jie; Shi, Hong-xin; Chen, Qing-ling; Chen, Yu-xi
2009-03-01
In order to ensure high-quality X-ray fluorescence spectrometry (XRF) analysis, an inductive bead fusion machine was developed. The prototype consists of super-audio IGBT induction heating power supply, rotation and swing mechanisms, and programmable logic controller (PLC). The system can realize sequence control, mechanical movement control, output current and temperature control. Experimental results show that the power supply can operate at an ideal quasi-resonant state, in which the expected power output and the required temperature can be achieved for rapid heating and the uniform formation of glass beads respectively.
The role of pelvis-thorax coupling in controlling within-golf club swing speed.
Lamb, Peter F; Pataky, Todd C
2018-02-23
Pelvis-thorax coordination has been recognised to be associated with swing speed. Increasing angular separation between the pelvis and thorax has been thought to initiate the stretch shortening cycle and lead to increased clubhead speed. The purpose of this study was to determine whether pelvis-thorax coupling played a significant role in regulating clubhead speed, in a group of low-handicap golfers (mean handicap = 4.1). Sixteen participants played shots to target distances determined based on their typical 5- and 6-iron shot distances. Half the difference between median 5- and 6-iron distance for each participant was used to create three swing effort conditions: "minus", "norm", and "plus". Ten shots were played under each swing effort condition using both the 5-iron and 6-iron, resulting in six shot categories and 60 shots per participant. No significant differences were found for X-factor for club or swing effort. X-factor stretch showed significant differences for club and swing effort. Continuous relative phase (CRP) results mainly showed evidence of the stretch shortening cycle in the downswing and that it was more pronounced late in the downswing as swing effort increased. Substantial inter-individual CRP variability demonstrated the need for individual analyses when investigating coordination in the golf swing.
Uh, Kyungchan; Yoon, Bora; Lee, Chan Woo; Kim, Jong-Man
2016-01-20
Electroactive materials that change shape in response to electrical stimulation can serve as actuators. Electroactive actuators of this type have great utility in a variety of technologies, including biomimetic artificial muscles, robotics, and sensors. Electroactive actuators developed to date often suffer from problems associated with the need to use electrolytes, slow response times, high driving voltages, and short cycle lifetimes. Herein, we report an electrolyte-free, single component, polymer electroactive actuator, which has a fast response time, high durability, and requires a low driving voltage (<5 V). The process employed for production of this material involves wet-spinning of a preorganized camphorsulfonic acid (CSA)-doped polyaniline (PANI) gel, which generates long, flexible, and conductive (∼270 S/cm) microfibers. Reversible bending motions take place upon application of an alternating current (AC) to the PANI polymer. This motion, promoted by a significantly low driving voltage (<0.5 V) in the presence of an external magnetic field, has a very large swinging speed (9000 swings/min) that lies in the range of those of flies and bees (1000-15000 swings/min) and is fatigue-resistant (>1000000 cycles).
Goertz, R.C.
1957-09-17
A device that reduces or eliminntes the swing of an object being transported by a traveling crane is described. The supporting cable of the crane extends through a guide and follower positioned below the crane by an electric motor and follow-up circuit. The swing or horizontal motion of the cable is detected by the follower, and a signal is generated that will cause the motor to move the follower in opposition to the motion of the swing thus having a dampening effect on the pendulum action of the supported body. This improvement is particularly valuable when the supported load may be so radioactive that a person could not manually stop the swing.
Cricket Ball Aerodynamics: Myth Versus Science
NASA Technical Reports Server (NTRS)
Mehta, Rabindra D.; Koga, Demmis J. (Technical Monitor)
2000-01-01
Aerodynamics plays a prominent role in the flight of a cricket ball released by a bowler. The main interest is in the fact that the ball can follow a curved flight path that is not always under the control of the bowler. ne basic aerodynamic principles responsible for the nonlinear flight or "swing" of a cricket ball were identified several years ago and many papers have been published on the subject. In the last 20 years or so, several experimental investigations have been conducted on cricket ball swing, which revealed the amount of attainable swing, and the parameters that affect it. A general overview of these findings is presented with emphasis on the concept of late swing and the effects of meteorological conditions on swing. In addition, the relatively new concept of "reverse" swing, how it can be achieved in practice and the role in it of ball "tampering", are discussed in detail. A discussion of the "white" cricket ball used in last year's World Cup, which supposedly possesses different swing properties compared to a conventional red ball, is also presented.
Effects of moment of inertia on restricted motion swing speed.
Schorah, David; Choppin, Simon; James, David
2015-06-01
In many sports, the maximum swing speed of a racket, club, or bat is a key performance parameter. Previous research in multiple sports supports the hypothesis of an inverse association between the swing speed and moment of inertia of an implement. The aim of this study was to rigorously test and quantify this relationship using a restricted swinging motion. Eight visually identical rods with a common mass but variable moment of inertia were manufactured. Motion capture technology was used to record eight participants' maximal effort swings with the rods. Strict exclusion criteria were applied to data that did not adhere to the prescribed movement pattern. The study found that for all participants, swing speed decreased with respect to moment of inertia according to a power relationship. However, in contrast to previous studies, the rate of decrease varied from participant to participant. With further analysis it was found that participants performed more consistently at the higher end of the moment of inertia range tested. The results support the inverse association between swing speed and moment of inertia but only for higher moment of inertia implements.
Methods for separation/purification utilizing rapidly cycled thermal swing sorption
Tonkovich, Anna Lee Y.; Monzyk, Bruce F.; Wang, Yong; VanderWiel, David P.; Perry, Steven T.; Fitzgerald, Sean P.; Simmons, Wayne W.; McDaniel, Jeffrey S.; Weller, Jr., Albert E.
2004-11-09
The present invention provides apparatus and methods for separating fluid components. In preferred embodiments, the apparatus and methods utilize microchannel devices with small distances for heat and mass transfer to achieve rapid cycle times and surprisingly large volumes of fluid components separated in short times using relatively compact hardware.
Simon, Ann M.; Hargrove, Levi J.
2016-01-01
Powered knee-ankle prostheses are capable of providing net-positive mechanical energy to amputees. Yet, there are limitless ways to deliver this energy throughout the gait cycle. It remains largely unknown how different combinations of active knee and ankle assistance affect the walking mechanics of transfemoral amputees. This study assessed the relative contributions of stance phase knee swing initiation, increasing ankle stiffness and powered plantarflexion as three unilateral transfemoral amputees walked overground at their self-selected walking speed. Five combinations of knee and ankle conditions were evaluated regarding the kinematics and kinetics of the amputated and intact legs using repeated measures analyses of variance. We found eliminating active knee swing initiation or powered plantarflexion was linked to increased compensations of the ipsilateral hip joint during the subsequent swing phase. The elimination of knee swing initiation or powered plantarflexion also led to reduced braking ground reaction forces of the amputated and intact legs, and influenced both sagittal and frontal plane loading of the intact knee joint. Gradually increasing prosthetic ankle stiffness influenced the shape of the prosthetic ankle plantarflexion moment, more closely mirroring the intact ankle moment. Increasing ankle stiffness also corresponded to increased prosthetic ankle power generation (despite a similar maximum stiffness value across conditions) and increased braking ground reaction forces of the amputated leg. These findings further our understanding of how to deliver assistance with powered knee-ankle prostheses and the compensations that occur when specific aspects of assistance are added/removed. PMID:26807889
Hunting for swinging millisecond pulsars with XMM-Newton
NASA Astrophysics Data System (ADS)
Papitto, Alessandro
2013-10-01
The recent XMM discovery of a millisecond pulsar swinging between an accretion- powered (X-ray) and a rotation-powered (radio) pulsar state provided the final evidence of the evolutionary link between these two classes, demonstrating that transitions between the two states can be observed over of a few weeks. We propose a ToO program (made of 3 triggers of 60 ks, over a 3years timescale) aimed at detecting X-ray accretion powered pulsations in sources already known as ms radio pulsars. Candidates are restricted to black widows and redbacks, systems in an evolutionary phase that allows state transitions. Enlarging the number of systems in this transitional phase is crucial to test binary evolution theories, and to study the disk-field interaction over a large range of mass accretion rates.
Development of a Temperature Sensor for Jet Engine and Space Mission Applications
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad; Elbuluk, Malik; Culley, Dennis
2008-01-01
Electronics for Distributed Turbine Engine Control and Space Exploration Missions are expected to encounter extreme temperatures and wide thermal swings. In particular, circuits deployed in a jet engine compartment are likely to be exposed to temperatures well exceeding 150 C. To meet this requirement, efforts exist at the NASA Glenn Research Center (GRC), in support of the Fundamental Aeronautics Program/Subsonic Fixed Wing Project, to develop temperature sensors geared for use in high temperature environments. The sensor and associated circuitry need to be located in the engine compartment under distributed control architecture to simplify system design, improve reliability, and ease signal multiplexing. Several circuits were designed using commercial-off-the-shelf as well as newly-developed components to perform temperature sensing at high temperatures. The temperature-sensing circuits will be described along with the results pertaining to their performance under extreme temperature.
Investigating Liquid CO2 as a Coolant for a MTSA Heat Exchanger Design
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Padilla, Sebastian; Powers, Aaron; Iacomini, Christie
2009-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO 2) control for a future Portable Life Support System (PLSS), as well as water recycling. CO 2 removal and rejection is accomplished by driving a sorbent through a temperature swing of approximately 210 K to 280 K . The sorbent is cooled to these sub-freezing temperatures by a Sublimating Heat Exchanger (SHX) with liquid coolant expanded to sublimation temperatures. Water is the baseline coolant available on the moon, and if used, provides a competitive solution to the current baseline PLSS schematic. Liquid CO2 (LCO2) is another non-cryogenic coolant readily available from Martian resources which can be produced and stored using relatively low power and minimal infrastructure. LCO 2 expands from high pressure liquid (5800 kPa) to Mars ambient (0.8 kPa) to produce a gas / solid mixture at temperatures as low as 156 K. Analysis and experimental work are presented to investigate factors that drive the design of a heat exchanger to effectively use this sink. Emphasis is given to enabling efficient use of the CO 2 cooling potential and mitigation of heat exchanger clogging due to solid formation. Minimizing mass and size as well as coolant delivery are also considered. The analysis and experimental work is specifically performed in an MTSA-like application to enable higher fidelity modeling for future optimization of a SHX design. In doing so, the work also demonstrates principles and concepts so that the design can be further optimized later in integrated applications (including Lunar application where water might be a choice of coolant).
A Low-cost Environmental Control System for Precise Radial Velocity Spectrometers
NASA Astrophysics Data System (ADS)
Sliski, David H.; Blake, Cullen H.; Halverson, Samuel
2017-12-01
We present an environmental control system (ECS) designed to achieve milliKelvin (mK) level temperature stability for small-scale astronomical instruments. This ECS is inexpensive and is primarily built from commercially available components. The primary application for our ECS is the high-precision Doppler spectrometer MINERVA-Red, where the thermal variations of the optical components within the instrument represent a major source of systematic error. We demonstrate ±2 mK temperature stability within a 0.5 m3 thermal enclosure using resistive heaters in conjunction with a commercially available PID controller and off-the-shelf thermal sensors. The enclosure is maintained above ambient temperature, enabling rapid cooling through heat dissipation into the surrounding environment. We demonstrate peak-to-valley (PV) temperature stability of better than 5 mK within the MINERVA-Red vacuum chamber, which is located inside the thermal enclosure, despite large temperature swings in the ambient laboratory environment. During periods of stable laboratory conditions, the PV variations within the vacuum chamber are less than 3 mK. This temperature stability is comparable to the best stability demonstrated for Doppler spectrometers currently achieving m s-1 radial velocity precision. We discuss the challenges of using commercially available thermoelectrically cooled CCD cameras in a temperature-stabilized environment, and demonstrate that the effects of variable heat output from the CCD camera body can be mitigated using PID-controlled chilled water systems. The ECS presented here could potentially provide the stable operating environment required for future compact “astrophotonic” precise radial velocity (PRV) spectrometers to achieve high Doppler measurement precision with a modest budget.
General closeup view of the swing span bridge in the ...
General close-up view of the swing span bridge in the close position, looking upriver. The pivot/center pier is positioned in the center of Tennessee River. Note: Each arm of the continuous swing span acts as simple spans. The total span over four (4) supports is partially continuous-- the middle panel at the center pier is continuous for bending moments, but discontinuous for shears. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Automatically closing swing gate closure assembly
Chang, Shih-Chih; Schuck, William J.; Gilmore, Richard F.
1988-01-01
A swing gate closure assembly for nuclear reactor tipoff assembly wherein the swing gate is cammed open by a fuel element or spacer but is reliably closed at a desired closing rate primarily by hydraulic forces in the absence of a fuel charge.
Gluck, George S; Bendo, John A; Spivak, Jeffrey M
2008-01-01
The golf swing imparts significant stress on the lumbar spine. Not surprisingly, low back pain (LBP) is one of the most common musculoskeletal complaints among golfers. This article provides a review of lumbar spine forces during the golf swing and other research available on swing biomechanics and muscle activity during trunk rotation. The role of "modern" and "classic" swing styles in golf-associated LBP, as well as LBP causation theories, treatment, and prevention strategies, are reviewed. A PubMed literature search was performed using various permutations of the following keywords: lumbar, spine, low, back, therapy, pain, prevention, injuries, golf, swing, trunk, rotation, and biomechanics. Articles were screened and selected for relevance to injuries in golf, swing mechanics, and biomechanics of the trunk and lumbar spine. Articles addressing treatment of LBP with discussions on trunk rotation or golf were also selected. Primary references were included from the initial selection of articles where appropriate. General web searches were performed to identify articles for background information on the sport of golf and postsurgical return to play. Prospective, randomized studies have shown that focus on the transversus abdominus (TA) and multifidi (MF) muscles is a necessary part of physical therapy for LBP. Some studies also suggest that the coaching of a "classic" golf swing and increasing trunk flexibility may provide additional benefit. There is a notable lack of studies separating the effects of swing modification from physical rehabilitation, and controlled trials are necessary to identify the true effectiveness of specific swing modifications for reducing LBP in golf. Although the establishment of a commonly used regimen to address all golf-associated LBP would be ideal, it may be more practical to apply basic principles mentioned in this article to the tailoring of a unique regimen for the patient. Guidelines for returning to golf after spine surgery are also discussed.
24. VIEW TO NORTHEAST FROM BRIDGE HOUSE. SOUTH SWING SPAN ...
24. VIEW TO NORTHEAST FROM BRIDGE HOUSE. SOUTH SWING SPAN (SEEN AS THE ROADWAY IN FOREGROUND) HAS CLOSED, NORTH SWING SPAN IS APPROACHING CLOSURE. - George P. Coleman Memorial Bridge, Spanning York River at U.S. Route 17, Yorktown, York County, VA
Kinetic constrained optimization of the golf swing hub path.
Nesbit, Steven M; McGinnis, Ryan S
2014-12-01
This study details an optimization of the golf swing, where the hand path and club angular trajectories are manipulated. The optimization goal was to maximize club head velocity at impact within the interaction kinetic limitations (force, torque, work, and power) of the golfer as determined through the analysis of a typical swing using a two-dimensional dynamic model. The study was applied to four subjects with diverse swing capabilities and styles. It was determined that it is possible for all subjects to increase their club head velocity at impact within their respective kinetic limitations through combined modifications to their respective hand path and club angular trajectories. The manner of the modifications, the degree of velocity improvement, the amount of kinetic reduction, and the associated kinetic limitation quantities were subject dependent. By artificially minimizing selected kinetic inputs within the optimization algorithm, it was possible to identify swing trajectory characteristics that indicated relative kinetic weaknesses of a subject. Practical implications are offered based upon the findings of the study. Key PointsThe hand path trajectory is an important characteristic of the golf swing and greatly affects club head velocity and golfer/club energy transfer.It is possible to increase the energy transfer from the golfer to the club by modifying the hand path and swing trajectories without increasing the kinetic output demands on the golfer.It is possible to identify relative kinetic output strengths and weakness of a golfer through assessment of the hand path and swing trajectories.Increasing any one of the kinetic outputs of the golfer can potentially increase the club head velocity at impact.The hand path trajectory has important influences over the club swing trajectory.
Kinetic Constrained Optimization of the Golf Swing Hub Path
Nesbit, Steven M.; McGinnis, Ryan S.
2014-01-01
This study details an optimization of the golf swing, where the hand path and club angular trajectories are manipulated. The optimization goal was to maximize club head velocity at impact within the interaction kinetic limitations (force, torque, work, and power) of the golfer as determined through the analysis of a typical swing using a two-dimensional dynamic model. The study was applied to four subjects with diverse swing capabilities and styles. It was determined that it is possible for all subjects to increase their club head velocity at impact within their respective kinetic limitations through combined modifications to their respective hand path and club angular trajectories. The manner of the modifications, the degree of velocity improvement, the amount of kinetic reduction, and the associated kinetic limitation quantities were subject dependent. By artificially minimizing selected kinetic inputs within the optimization algorithm, it was possible to identify swing trajectory characteristics that indicated relative kinetic weaknesses of a subject. Practical implications are offered based upon the findings of the study. Key Points The hand path trajectory is an important characteristic of the golf swing and greatly affects club head velocity and golfer/club energy transfer. It is possible to increase the energy transfer from the golfer to the club by modifying the hand path and swing trajectories without increasing the kinetic output demands on the golfer. It is possible to identify relative kinetic output strengths and weakness of a golfer through assessment of the hand path and swing trajectories. Increasing any one of the kinetic outputs of the golfer can potentially increase the club head velocity at impact. The hand path trajectory has important influences over the club swing trajectory. PMID:25435779
Aldridge Whitehead, Jennifer M; Wolf, Erik J; Scoville, Charles R; Wilken, Jason M
2014-10-01
Stair ascent can be difficult for individuals with transfemoral amputation because of the loss of knee function. Most individuals with transfemoral amputation use either a step-to-step (nonreciprocal, advancing one stair at a time) or skip-step strategy (nonreciprocal, advancing two stairs at a time), rather than a step-over-step (reciprocal) strategy, because step-to-step and skip-step allow the leading intact limb to do the majority of work. A new microprocessor-controlled knee (Ottobock X2(®)) uses flexion/extension resistance to allow step-over-step stair ascent. We compared self-selected stair ascent strategies between conventional and X2(®) prosthetic knees, examined between-limb differences, and differentiated stair ascent mechanics between X2(®) users and individuals without amputation. We also determined which factors are associated with differences in knee position during initial contact and swing within X2(®) users. Fourteen individuals with transfemoral amputation participated in stair ascent sessions while using conventional and X2(®) knees. Ten individuals without amputation also completed a stair ascent session. Lower-extremity stair ascent joint angles, moment, and powers and ground reaction forces were calculated using inverse dynamics during self-selected strategy and cadence and controlled cadence using a step-over-step strategy. One individual with amputation self-selected a step-over-step strategy while using a conventional knee, while 10 individuals self-selected a step-over-step strategy while using X2(®) knees. Individuals with amputation used greater prosthetic knee flexion during initial contact (32.5°, p = 0.003) and swing (68.2°, p = 0.001) with higher intersubject variability while using X2(®) knees compared to conventional knees (initial contact: 1.6°, swing: 6.2°). The increased prosthetic knee flexion while using X2(®) knees normalized knee kinematics to individuals without amputation during swing (88.4°, p = 0.179) but not during initial contact (65.7°, p = 0.002). Prosthetic knee flexion during initial contact and swing were positively correlated with prosthetic limb hip power during pull-up (r = 0.641, p = 0.046) and push-up/early swing (r = 0.993, p < 0.001), respectively. Participants with transfemoral amputation were more likely to self-select a step-over-step strategy similar to individuals without amputation while using X2(®) knees than conventional prostheses. Additionally, the increased prosthetic knee flexion used with X2(®) knees placed large power demands on the hip during pull-up and push-up/early swing. A modified strategy that uses less knee flexion can be used to allow step-over-step ascent in individuals with less hip strength.
Swing-bed services under the Medicare program, 1984-87
Silverman, Herbert A.
1990-01-01
Under Medicare, swing beds are beds that can be used by small rural hospitals to furnish both acute and post-acute care. The swing-bed program was instituted under the provisions of the Omnibus Reconciliation Act of 1980 (Public Law 96-499). Under Medicare, post-acute care in the hospital would be covered as services equivalent to skilled nursing facility level of care. Data show that the program has had a rapid rate of growth. By 1987, swing beds accounted for 9.7 percent of the admissions to skilled nursing facility services, 6.0 percent of the covered days of care, and 6.2 percent of the reimbursements. Over one-half of the swing-bed services are furnished in the North Central States. PMID:10113275
Swing Weights of Baseball and Softball Bats
NASA Astrophysics Data System (ADS)
Russell, Dan
2010-10-01
Baseball and softball bats are sold according to length in inches and weight in ounces. Much to the consternation of players buying new bats, however, not all bats that weigh the same swing the same. The reason for this has to do with moment of inertia of the bat about a pivot point on the handle, or what the sporting goods industry refers to as swing weight.2-3 A number of recent field studies4-7 have confirmed that the speed with which a player can swing a baseball or softball bat depends more on the bat's moment of inertia than on its mass. In this paper we investigate the moment of inertia (swing weight) of a variety of baseball and softball bats.
NASA Astrophysics Data System (ADS)
Wang, Yang; Yu, Jianqun; Yu, Yajun
2018-05-01
To solve the problems in the DEM simulations of the screening process of a swing-bar sieve, in this paper we propose the real-virtual boundary method to build the geometrical model of the screen deck on a swing-bar sieve. The motion of the swing-bar sieve is modelled by the planer multi-body kinematics. A coupled model of the discrete element method (DEM) with multi-body kinematics (MBK) is presented to simulate the flowing and passing processes of soybean particles on the screen deck. By the comparison of the simulated results with the experimental results of the screening process of the LA-LK laboratory scale swing-bar sieve, the feasibility and validity of the real-virtual boundary method and the coupled DEM-MBK model we proposed in this paper can be verified. This work provides the basis for the optimization design of the swing-bar sieve with circular apertures and complex motion.
Practical Applications of Reading Research.
ERIC Educational Resources Information Center
Harris, Albert J.
There are three main reasons why reading research has not had a stronger influence on what goes on in schools. The first reason is the powerful impact of social forces such as the bandwagon effect, the pendulum swing, and the prevailing climate of opinion. These factors determine to an unfortunately large degree whether or not particular research…
Pendula, Models, Constructivism and Reality
ERIC Educational Resources Information Center
Nola, Robert
2004-01-01
It is argued that Galileo made an important breakthrough in the methodology of science by considering idealized models of phenomena such as free fall, swinging pendula and the like, which can conflict with experience. The idealized models are constructs largely by our reasoning processes applied to the theoretical situation at hand. On this view,…
Serials vs. the Dollar Dilemma: Currency Swings and Rising Costs Play Havoc with Prices.
ERIC Educational Resources Information Center
Ketcham, Lee; Born, Kathleen
1995-01-01
This periodical price survey examines pricing trends, currency fluctuation and other predictors of 1996 serials costs. Tables are derived from analysis of three Institute for Scientific Information (ISI) databases and reflect subscription rates of large libraries. Sidebars include cost history information specific to mid-size to smaller academic…
Testing and Validation of the Dynamic Inertia Measurement Method
NASA Technical Reports Server (NTRS)
Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David
2015-01-01
The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.
Effects of special composite stretching on the swing of amateur golf players
Lee, Joong-chul; Lee, Sung-wan; Yeo, Yun-ghi; Park, Gi Duck
2015-01-01
[Purpose] The study investigated stretching for safer a golf swing compared to present stretching methods for proper swings in order to examine the effects of stretching exercises on golf swings. [Subjects] The subjects were 20 amateur golf club members who were divided into two groups: an experimental group which performed stretching, and a control group which did not. The subjects had no bone deformity, muscle weakness, muscle soreness, or neurological problems. [Methods] A swing analyzer and a ROM measuring instrument were used as the measuring tools. The swing analyzer was a GS400-golf hit ball analyzer (Korea) and the ROM measuring instrument was a goniometer (Korea). [Results] The experimental group showed a statistically significant improvement in driving distance. After the special stretching training for golf, a statistically significant difference in hit-ball direction deviation after swings were found between the groups. The experimental group showed statistically significant decreases in hit ball direction deviation. After the special stretching training for golf, statistically significant differences in hit-ball speed were found between the groups. The experimental group showed significant increases in hit-ball speed. [Conclusion] To examine the effects of a special stretching program for golf on golf swing-related factors, 20 male amateur golf club members performed a 12-week stretching training program. After the golf stretching training, statistically significant differences were found between the groups in hit-ball driving distance, direction deviation, deflection distance, and speed. PMID:25995553
Effects of special composite stretching on the swing of amateur golf players.
Lee, Joong-Chul; Lee, Sung-Wan; Yeo, Yun-Ghi; Park, Gi Duck
2015-04-01
[Purpose] The study investigated stretching for safer a golf swing compared to present stretching methods for proper swings in order to examine the effects of stretching exercises on golf swings. [Subjects] The subjects were 20 amateur golf club members who were divided into two groups: an experimental group which performed stretching, and a control group which did not. The subjects had no bone deformity, muscle weakness, muscle soreness, or neurological problems. [Methods] A swing analyzer and a ROM measuring instrument were used as the measuring tools. The swing analyzer was a GS400-golf hit ball analyzer (Korea) and the ROM measuring instrument was a goniometer (Korea). [Results] The experimental group showed a statistically significant improvement in driving distance. After the special stretching training for golf, a statistically significant difference in hit-ball direction deviation after swings were found between the groups. The experimental group showed statistically significant decreases in hit ball direction deviation. After the special stretching training for golf, statistically significant differences in hit-ball speed were found between the groups. The experimental group showed significant increases in hit-ball speed. [Conclusion] To examine the effects of a special stretching program for golf on golf swing-related factors, 20 male amateur golf club members performed a 12-week stretching training program. After the golf stretching training, statistically significant differences were found between the groups in hit-ball driving distance, direction deviation, deflection distance, and speed.
Wurzbacher, Jan Andre; Gebald, Christoph; Piatkowski, Nicolas; Steinfeld, Aldo
2012-08-21
A temperature-vacuum swing (TVS) cyclic process is applied to an amine-functionalized nanofibrilated cellulose sorbent to concurrently extract CO(2) and water vapor from ambient air. The promoting effect of the relative humidity on the CO(2) capture capacity and on the amount of coadsorbed water is quantified. The measured specific CO(2) capacities range from 0.32 to 0.65 mmol/g, and the corresponding specific H(2)O capacities range from 0.87 to 4.76 mmol/g for adsorption temperatures varying between 10 and 30 °C and relative humidities varying between 20 and 80%. Desorption of CO(2) is achieved at 95 °C and 50 mbar(abs) without dilution by a purge gas, yielding a purity exceeding 94.4%. Sorbent stability and a closed mass balance for both H(2)O and CO(2) are demonstrated for ten consecutive adsorption-desorption cycles. The specific energy requirements of the TVS process based on the measured H(2)O and CO(2) capacities are estimated to be 12.5 kJ/mol(CO2) of mechanical (pumping) work and between 493 and 640 kJ/mol(CO2) of heat at below 100 °C, depending on the air relative humidity. For a targeted CO(2) capacity of 2 mmol/g, the heat requirement would be reduced to between 272 and 530 kJ/mol(CO2), depending strongly on the amount of coadsorbed water.
MoS2 Negative-Capacitance Field-Effect Transistors with Subthreshold Swing below the Physics Limit.
Liu, Xingqiang; Liang, Renrong; Gao, Guoyun; Pan, Caofeng; Jiang, Chunsheng; Xu, Qian; Luo, Jun; Zou, Xuming; Yang, Zhenyu; Liao, Lei; Wang, Zhong Lin
2018-05-21
The Boltzmann distribution of electrons induced fundamental barrier prevents subthreshold swing (SS) from less than 60 mV dec -1 at room temperature, leading to high energy consumption of MOSFETs. Herein, it is demonstrated that an aggressive introduction of the negative capacitance (NC) effect of ferroelectrics can decisively break the fundamental limit governed by the "Boltzmann tyranny". Such MoS 2 negative-capacitance field-effect transistors (NC-FETs) with self-aligned top-gated geometry demonstrated here pull down the SS value to 42.5 mV dec -1 , and simultaneously achieve superior performance of a transconductance of 45.5 μS μm and an on/off ratio of 4 × 10 6 with channel length less than 100 nm. Furthermore, the inserted HfO 2 layer not only realizes a stable NC gate stack structure, but also prevents the ferroelectric P(VDF-TrFE) from fatigue with robust stability. Notably, the fabricated MoS 2 NC-FETs are distinctly different from traditional MOSFETs. The on-state current increases as the temperature decreases even down to 20 K, and the SS values exhibit nonlinear dependence with temperature due to the implementation of the ferroelectric gate stack. The NC-FETs enable fundamental applications through overcoming the Boltzmann limit in nanoelectronics and open up an avenue to low-power transistors needed for many exciting long-endurance portable consumer products. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Rosen, Micha; Mulloth, Lila; Varghese, Mini
2005-01-01
This paper describes the results of long-duration testing of a temperature-swing adsorption compressor that has application in the International Space Station (ISS) and future spacecraft for closing the air revitalization loop. The air revitalization system of the ISS operates in an open loop mode and relies on the resupply of oxygen and other consumables from Earth for the life support of astronauts. A compressor is required for delivering the carbon dioxide from a removal assembly to a reduction unit to recover oxygen and thereby closing the air-loop. The TSAC is a solid-state compressor that has the capability to remove CO2 from a low-pressure source, and subsequently store, compress, and deliver at a higher pressure as required by a processor. The TSAC is an ideal interface device for CO2 removal and reduction units in the air revitalization loop of a spacecraft for oxygen recovery. The TSAC was developed and its operation was successfully verified in integration tests with the flight-like Carbon Dioxide Removal Assembly (CDRA) at Marshall Space Flight Center prior to the long-duration tests. Long-duration tests reveal the impacts of repeated thermal cycling on the compressor components and the adsorbent material.
Trends in snowfall versus rainfall in the Western United States--Revisited
NASA Astrophysics Data System (ADS)
Dettinger, M. D.; Knowles, N.; Cayan, D. R.
2015-12-01
Knowles et al. (J. Climate, 2006) documented long-term (1949-2004) trends in precipitation form, with a smaller fraction of precipitation falling, in recent decades, on days with reported snow compared to days when no snow was reported (and when precipitation was presumably rain). This precipitation-amount-corrected trend was found at three-quarters of 261 cooperative weather stations across the region. The trends correlated with corresponding trends towards warmer winter air temperatures at the weather stations involved. An update of those analyses through the more recent period indicates that the overall swing towards less precipitation fraction occurring on snowy days has continued through the intervening years, with 21st Century rain/snow fractions remaining significantly higher than historical norms at most stations. The same data have also been used to develop site-specific statistical relations between precipitation form (snowy-day precipitation vs purely rainy day) and air temperatures by logistical regressions at over 200 stations across the West, to determine whether the general temperature trends mentioned above have, in fact, been large enough to explain the trending precipitation forms. That is, were the warming trends detected across the West large enough to actually raise temperatures above the local snow-rain thresholds at most stations? The regression relations show that the temperature at which half of the wet days have been snowy historically varies, from station to station, across a range from -2ºC to +4ºC. Thus at some stations winter storm temperatures would have to rise above about -2ºC to markedly impact precipitation forms, while at other stations, temperature had to rise above +4ºC. Nonetheless, observed temperature trends since 1950 have been sufficient to explain the observed regional precipitation-form trends. The fitted precipitation form-temperature relations also provide a basis for estimating precipitation forms in hydrological models and in climate-change projections across the region, allowing—for example—more geographically informed projections of precipitation-form changes under future climates. On the whole, though, the expected relations between warming trends and precipitation-form trends found by Knowles et al. (2006) continue to hold.
CFD Analysis of Swing of Cricket Ball and Trajectory Prediction
NASA Astrophysics Data System (ADS)
G, Jithin; Tom, Josin; Ruishikesh, Kamat; Jose, Jyothish; Kumar, Sanjay
2013-11-01
This work aims to understand the aerodynamics associated with the flight and swing of a cricket ball and predict its flight trajectory over the course of the game: at start (smooth ball) and as the game progresses (rough ball). Asymmetric airflow over the ball due to seam orientation and surface roughness can cause flight deviation (swing). The values of Drag, Lift and Side forces which are crucial for determining the trajectory of the ball were found with the help of FLUENT using the standard K- ɛ model. Analysis was done to study how the ball velocity, spin imparted to be ball and the tilt of the seam affects the movement of the ball through air. The governing force balance equations in 3 dimensions in combination a MATLAB code which used Heun's method was used for obtaining the trajectory of the ball. The conditions for the conventional swing and reverse swing to occur were deduced from the analysis and found to be in alignment with the real life situation. Critical seam angle for maximum swing and transition speed for normal to reverse swing were found out. The obtained trajectories were compared to real life hawk eye trajectories for validation. The analysis results were in good agreement with the real life situation.
Spine biomechanics associated with the shortened, modern one-plane golf swing.
Dale, R Barry; Brumitt, Jason
2016-06-01
The purpose of this study was to compare kinetic, kinematic, and performance variables associated with full and shortened modern backswings in a skilled group of modern swing (one-plane) golfers. Shortening the modern golf backswing is proposed to reduce vertebral spine stress, but supporting evidence is lacking and performance implications are unknown. Thirteen male golfers performed ten swings of each swing type using their own 7-iron club. Biomechanical-dependent variables included the X-Factor kinematic data and spine kinetics. Performance-related dependent variables included club head velocity (CHV), shot distance, and accuracy (distance from the target line). Data were analysed with repeated measures ANOVA with an a priori alpha of 0.05 (SPSS 22.0, IBM, Armonk, NY, USA). We found significant reductions for the X-Factor (p < 0.05) between the full and shortened swings. The shortened swing condition ameliorated vertebral compression force from 7.6 ± 1.4 to 7.0 ± 1.7 N (normalised to body weight, p = 0.01) and significantly reduced CHV (p < 0.05) by ~2 m/s with concomitant shot distance diminution by ~10 m (p < 0.05). Further research is necessary to examine the applicability of a shortened swing for golfers with low back pain.
Rehabilitation of Low Back Pain in Golfers
Finn, Christopher
2013-01-01
Context: Low back injuries are the most common injury in golf. Best practice guidelines for rehabilitation and prevention of these injuries are helpful for health care professionals and all golfers. Objective: To establish a best practice clinical model for low back pain in golfers from diagnosis through treatment and rehabilitation to return to golf. Evidence Acquisition: The PubMed database and Google Scholar were searched from 1993 to 2012 with the following keywords: golf and low back injury, low back injury, golf and low back pain, golf injury prevention, golf modern swing, muscles in golf swing, low back rehabilitation, diaphragm, and core stability. All studies addressed in some manner the rehabilitation, prevention, or return to sport from low back injury, preferably in direct relation to golf, as well as muscle firing patterns used during the golf swing. Results: Best practice for rehabilitation and prevention of low back injury in golf appears to be through a multidisciplinary approach. Conclusion: Movement patterns, muscle imbalances, and type of swing utilized all have a direct effect on the forces applied to the spine during the golf swing and need to be assessed to prevent or rehabilitate injury. Understanding the golf swing and how the body works during the swing is necessary. PMID:24459546
Van Hooren, Bas; Bosch, Frans
2017-12-01
It is widely assumed that there is an eccentric hamstring muscle fibre action during the swing phase of high-speed running. However, animal and modelling studies in humans show that the increasing distance between musculotendinous attachment points during forward swing is primarily due to passive lengthening associated with the take-up of muscle slack. Later in the swing phase, the contractile element (CE) maintains a near isometric action while the series elastic (tendinous) element first stretches as the knee extends, and then recoils causing the swing leg to forcefully retract prior to ground contact. Although modelling studies showed some active lengthening of the contractile (muscular) element during the mid-swing phase of high-speed running, we argue that the increasing distance between the attachment points should not be interpreted as an eccentric action of the CE due to the effects of muscle slack. Therefore, there may actually be no significant eccentric, but rather predominantly an isometric action of the hamstrings CE during the swing phase of high-speed running when the attachment points of the hamstrings are moving apart. Based on this, we propose that isometric rather than eccentric exercises are a more specific way of conditioning the hamstrings for high-speed running.
A Pilot Study of Horizontal Head and Eye Rotations in Baseball Batting.
Fogt, Nick; Persson, Tyler W
2017-08-01
The purpose of the study was to measure and compare horizontal head and eye tracking movements as baseball batters "took" pitches and swung at baseball pitches. Two former college baseball players were tested in two conditions. A pitching machine was used to project tennis balls toward the subjects. In the first condition, subjects acted as if they were taking (i.e., not swinging) the pitches. In the second condition, subjects attempted to bat the pitched balls. Head movements were measured with an inertial sensor; eye movements were measured with a video eye tracker. For each condition, the relationship between the horizontal head and eye rotations was similar for the two subjects, as were the overall head-, eye-, and gaze-tracking strategies. In the "take" condition, head movements in the direction of the ball were larger than eye movements for much of the pitch trajectory. Large eye movements occurred only late in the pitch trajectory. Gaze was directed near the ball until approximately 150 milliseconds before the ball arrived at the batter, at which time gaze was directed ahead of the ball to a location near that occupied when the ball crosses the plate. In the "swing" condition, head movements in the direction of the ball were larger than eye movements throughout the pitch trajectory. Gaze was directed near the ball until approximately 50 to 60 milliseconds prior to pitch arrival at the batter. Horizontal head rotations were larger than horizontal eye rotations in both the "take" and "swing" conditions. Gaze was directed ahead of the ball late in the pitch trajectory in the "take" condition, whereas gaze was directed near the ball throughout much of the pitch trajectory in the "swing" condition.
Obusek, J P; Holt, K G; Rosenstein, R M
1995-07-01
Human leg swinging is modeled as the harmonic motion of a hybrid mass-spring pendulum. The cycle period is determined by a gravitational component and an elastic component, which is provided by the attachment of a soft-tissue/muscular spring of variable stiffness. To confirm that the stiffness of the spring changes with alterations in the inertial properties of the oscillator and that stiffness is relevant for the control of cycle period, we conducted this study in which the simple pendulum equivalent length was experimentally manipulated by adding mass to the ankle of a comfortably swinging leg. Twenty-four young, healthy adults were videotaped as they swung their right leg under four conditions: no added mass and with masses of 2.27, 4.55, and 6.82kg added to the ankle. Strong, linear relationships between the acceleration and displacement of the swinging leg within subjects and conditions were found, confirming the motion's harmonic nature. Cycle period significantly increased with the added mass. However, the observed increases were not as large as would be predicted by the induced changes in the gravitational component alone. These differences were interpreted as being due to increases in the active muscular stiffness. Significant linear increases in the elastic component (and hence stiffness) were demonstrated with increases in the simple pendulum equivalent length in 20 of the individual subjects, with r2 values ranging between 0.89 and 0.99. Significant linear relationships were also demonstrated between the elastic and gravitational components in 22 subjects, with individual r2 values between 0.90 and 0.99.(ABSTRACT TRUNCATED AT 250 WORDS)
Hysteresis-Free Carbon Nanotube Field-Effect Transistors.
Park, Rebecca S; Hills, Gage; Sohn, Joon; Mitra, Subhasish; Shulaker, Max M; Wong, H-S Philip
2017-05-23
While carbon nanotube (CNT) field-effect transistors (CNFETs) promise high-performance and energy-efficient digital systems, large hysteresis degrades these potential CNFET benefits. As hysteresis is caused by traps surrounding the CNTs, previous works have shown that clean interfaces that are free of traps are important to minimize hysteresis. Our previous findings on the sources and physics of hysteresis in CNFETs enabled us to understand the influence of gate dielectric scaling on hysteresis. To begin with, we validate through simulations how scaling the gate dielectric thickness results in greater-than-expected benefits in reducing hysteresis. Leveraging this insight, we experimentally demonstrate reducing hysteresis to <0.5% of the gate-source voltage sweep range using a very large-scale integration compatible and solid-state technology, simply by fabricating CNFETs with a thin effective oxide thickness of 1.6 nm. However, even with negligible hysteresis, large subthreshold swing is still observed in the CNFETs with multiple CNTs per transistor. We show that the cause of large subthreshold swing is due to threshold voltage variation between individual CNTs. We also show that the source of this threshold voltage variation is not explained solely by variations in CNT diameters (as is often ascribed). Rather, other factors unrelated to the CNTs themselves (i.e., process variations, random fixed charges at interfaces) are a significant factor in CNT threshold voltage variations and thus need to be further improved.
The influence of muscles on knee flexion during the swing phase of gait.
Piazza, S J; Delp, S L
1996-06-01
Although the movement of the leg during swing phase is often compared to the unforced motion of a compound pendulum, the muscles of the leg are active during swing and presumably influence its motion. To examine the roles of muscles in determining swing phase knee flexion, we developed a muscle-actuated forward dynamic simulation of the swing phase of normal gait. Joint angles and angular velocities at toe-off were derived from experimental measurements, as were pelvis motions and muscle excitations. Joint angles and joint moments resulting from the simulation corresponded to experimental measurements made during normal gait. Muscular joint moments and initial joint angular velocities were altered to determine the effects of each upon peak knee flexion in swing phase. As expected, the simulation demonstrated that either increasing knee extension moment or decreasing toe-off knee flexion velocity decreased peak knee flexion. Decreasing hip flexion moment or increasing toe-off hip flexion velocity also caused substantial decreases in peak knee flexion. The rectus femoris muscle played an important role in regulating knee flexion; removal of the rectus femoris actuator from the model resulted in hyperflexion of the knee, whereas an increase in the excitation input to the rectus femoris actuator reduced knee flexion. These findings confirm that reduced knee flexion during the swing phase (stiff-knee gait) may be caused by overactivity of the rectus femoris. The simulations also suggest that weakened hip flexors and stance phase factors that determine the angular velocities of the knee and hip at toe-off may be responsible for decreased knee flexion during swing phase.
Ground reaction forces produced by two different hockey skating arm swing techniques.
Hayward-Ellis, Julie; Alexander, Marion J L; Glazebrook, Cheryl M; Leiter, Jeff
2017-10-01
The arm swing in hockey skating can have a positive effect on the forces produced by each skate, and the resulting velocity from each push off. The main purpose of this study was to measure the differences in ground reaction forces (GRFs) produced from an anteroposterior versus a mediolateral style hockey skating arm swing. Twenty-four elite-level female hockey players performed each technique while standing on a ground-mounted force platform, and all trials were filmed using two video cameras. Force data was assessed for peak scaled GRFs in the frontal and sagittal planes, and resultant GRF magnitude and direction. Upper limb kinematics were assessed from the video using Dartfish video analysis software, confirming that the subjects successfully performed two distinct arm swing techniques. The mediolateral arm swing used a mean of 18.38° of glenohumeral flexion/extension and 183.68° of glenohumeral abduction/adduction while the anteroposterior technique used 214.17° and 28.97° respectively. The results of this study confirmed that the mediolateral arm swing produced 37% greater frontal plane and 33% less sagittal plane GRFs than the anteroposterior arm swing. The magnitudes of the resultant GRFs were not significantly different between the two techniques; however, the mediolateral technique produced a resultant GRF with a significantly larger angle from the direction of travel (44.44°) as compared to the anteroposterior technique (31.60°). The results of this study suggest that the direction of GRFs produced by the mediolateral arm swing more closely mimic the direction of lower limb propulsion during the skating stride.
Stabilization of cat paw trajectory during locomotion
Klishko, Alexander N.; Farrell, Bradley J.; Beloozerova, Irina N.; Latash, Mark L.
2014-01-01
We investigated which of cat limb kinematic variables during swing of regular walking and accurate stepping along a horizontal ladder are stabilized by coordinated changes of limb segment angles. Three hypotheses were tested: 1) animals stabilize the entire swing trajectory of specific kinematic variables (performance variables); and 2) the level of trajectory stabilization is similar between regular and ladder walking and 3) is higher for forelimbs compared with hindlimbs. We used the framework of the uncontrolled manifold (UCM) hypothesis to quantify the structure of variance of limb kinematics in the limb segment orientation space across steps. Two components of variance were quantified for each potential performance variable, one of which affected it (“bad variance,” variance orthogonal to the UCM, VORT) while the other one did not (“good variance,” variance within the UCM, VUCM). The analysis of five candidate performance variables revealed that cats during both locomotor behaviors stabilize 1) paw vertical position during the entire swing (VUCM > VORT, except in mid-hindpaw swing of ladder walking) and 2) horizontal paw position in initial and terminal swing (except for the entire forepaw swing of regular walking). We also found that the limb length was typically stabilized in midswing, whereas limb orientation was not (VUCM ≤ VORT) for both limbs and behaviors during entire swing. We conclude that stabilization of paw position in early and terminal swing enables accurate and stable locomotion, while stabilization of vertical paw position in midswing helps paw clearance. This study is the first to demonstrate the applicability of the UCM-based analysis to nonhuman movement. PMID:24899676
The influence of material anisotropy on vibration at onset in a three-dimensional vocal fold model
Zhang, Zhaoyan
2014-01-01
Although vocal folds are known to be anisotropic, the influence of material anisotropy on vocal fold vibration remains largely unknown. Using a linear stability analysis, phonation onset characteristics were investigated in a three-dimensional anisotropic vocal fold model. The results showed that isotropic models had a tendency to vibrate in a swing-like motion, with vibration primarily along the superior-inferior direction. Anterior-posterior (AP) out-of-phase motion was also observed and large vocal fold vibration was confined to the middle third region along the AP length. In contrast, increasing anisotropy or increasing AP-transverse stiffness ratio suppressed this swing-like motion and allowed the vocal fold to vibrate in a more wave-like motion with strong medial-lateral motion over the entire medial surface. Increasing anisotropy also suppressed the AP out-of-phase motion, allowing the vocal fold to vibrate in phase along the entire AP length. Results also showed that such improvement in vibration pattern was the most effective with large anisotropy in the cover layer alone. These numerical predictions were consistent with previous experimental observations using self-oscillating physical models. It was further hypothesized that these differences may facilitate complete glottal closure in finite-amplitude vibration of anisotropic models as observed in recent experiments. PMID:24606284
NASA Technical Reports Server (NTRS)
Bower, Chad E.; Padilla, Sebastian A.; Iacomini, Christie S.; Paul, Heather L.
2010-01-01
This paper describes modeling methods for the three core components of a Metabolic heat regenerated Temperature Swing Adsorption (MTSA) subassembly: a sorbent bed, a sublimation (cooling) heat exchanger (SHX), and a condensing icing (warming) heat exchanger (CIHX). The primary function of the MTSA, removing carbon dioxide from a space suit Portable Life Support System (PLSS) ventilation loop, is performed via the sorbent bed. The CIHX is used to heat the sorbent bed for desorption and to remove moisture from the ventilation loop while the SHX is alternately employed to cool the sorbent bed via sublimation of a spray of water at low pressure to prepare the reconditioned bed for the next cycle. This paper describes subsystem heat a mass transfer modeling methodologies relevant to the description of the MTSA subassembly in Thermal Desktop and SINDA/FLUINT. Several areas of particular modeling interest are discussed. In the sorbent bed, capture of the translating carbon dioxide (CO2) front and associated local energy and mass balance in both adsorbing and desorbing modes is covered. The CIHX poses particular challenges for modeling in SINDA/FLUINT as accounting for solids states in fluid submodels are not a native capability. Methods for capturing phase change and latent heat of ice as well as the transport properties across a layer of low density accreted frost are developed. This extended modeling capacity is applicable to temperatures greater than 258 K. To extend applicability to the minimum device temperature of 235 K, a method for a mapped transformation of temperatures from below the limit temperatures to some value above is given along with descriptions for associated material property transformations and the resulting impacts to total heat and mass transfer. Similar considerations are given for the SHX along with functional relationships for areal sublimation rates as limited by flow mechanics in t1he outlet duct.
NASA Technical Reports Server (NTRS)
Bower, Chad; Padilla, Sebastian; Iacomini, Christie; Paul, Heather L.
2009-01-01
This paper describes modeling methods for the three core components of a Metabolic heat regenerated Temperature Swing Adsorption (MTSA) subassembly: the sorbent bed, a sublimation (cooling) heat exchanger (SHX), and a condensing icing (warming) heat exchanger (CIHX). The primary function of the MTSA, removing carbon dioxide from a ventilation loop, is performed via the sorbent bed. The CIHX is used to heat the sorbent bed for desorption and to remove moisture from the ventilation loop while the SHX is alternately employed to cool the sorbent bed via sublimation of a spray of water at low pressure to prepare the reconditioned bed for the next cycle. This paper describes a system level model of the MTSA as developed in Thermal Desktop and SINDA/FLUINT including assumptions on geometry and physical phenomena, modeling methodology and relevant pa ra mete rizatio ns. Several areas of particular modeling interest are discussed. In the sorbent bed, capture of the translating CO2 saturation front and associated local energy and mass balance in both adsorbing and desorbing modes is covered. The CIHX poses particular challenges for modeling in SINDA/FLUINT as accounting for solids states in fluid submodels are not a native capability. Methods for capturing phase change and latent heat of ice as well as the transport properties across a layer of low density accreted frost are developed. This extended modeling capacity is applicable to temperatures greater than 258 K. To extend applicability to the minimum device temperature of 235 K, a method for a mapped transformation of temperatures from below the limit temperatures to some value above is given along with descriptions for associated material property transformations and the resulting impacts to total heat and mass transfer. Similar considerations are shown for the SHX along with assumptions for flow mechanics and resulting model methods for sublimation in a flow.
Testing of an Amine-Based Pressure-Swing System for Carbon Dioxide and Humidity Control
NASA Technical Reports Server (NTRS)
Lin, Amy; Smith, Frederick; Sweterlitsch, Jeffrey; Graf, John; Nalette, Tim; Papale, William; Campbell, Melissa; Lu, Sao-Dung
2007-01-01
In a crewed spacecraft environment, atmospheric carbon dioxide (CO2) and moisture control is crucial. Hamilton Sundstrand has developed a stable and efficient amine-based CO2 and water vapor sorbent, SA9T, that is well-suited for use in a spacecraft environment. The sorbent is efficiently packaged in pressure-swing regenerable beds that are thermally linked to improve removal efficiency and minimize vehicle thermal loads. Flows are all controlled with a single spool valve. This technology has been baselined for the new Orion spacecraft. However, more data was needed on the operational characteristics of the package in a simulated spacecraft environment. A unit was therefore tested with simulated metabolic loads in a closed chamber at Johnson Space Center during the last third of 2006. Tests were run at a variety of cabin temperatures and with a range of operating conditions varying cycle time, vacuum pressure, air flow rate, and crew activity levels. Results of this testing are presented and potential flight operational strategies discussed.
High performance MoS2 TFT using graphene contact first process
NASA Astrophysics Data System (ADS)
Chang Chien, Chih-Shiang; Chang, Hsun-Ming; Lee, Wei-Ta; Tang, Ming-Ru; Wu, Chao-Hsin; Lee, Si-Chen
2017-08-01
An ohmic contact of graphene/MoS2 heterostructure is determined by using ultraviolet photoelectron spectroscopy (UPS). Since graphene shows a great potential to replace metal contact, a direct comparison of Cr/Au contact and graphene contact on the MoS2 thin film transistor (TFT) is made. Different from metal contacts, the work function of graphene can be modulated. As a result, the subthreshold swing can be improved. And when Vg
Teaching Your Gymnasts to Swing. Biomechanics in Plain Talk for the Novice Coach.
ERIC Educational Resources Information Center
Sim, Laura J.
1985-01-01
The key to successful uneven parallel bar routines lies in the rhythm and continuity of movement which is ensured through the element of swing. Diagrams are offered to help illustrate how the biomechanical principles of torque and momentum are essential to learning and developing the mechanics of swing. (DF)
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Dog, swing. 236.743 Section 236.743 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.743 Dog, swing. A locking dog mounted in such a manner that it is free to rotate on a trunnion which is riveted to a locking...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Dog, swing. 236.743 Section 236.743 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.743 Dog, swing. A locking dog mounted in such a manner that it is free to rotate on a trunnion which is riveted to a locking...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Dog, swing. 236.743 Section 236.743 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.743 Dog, swing. A locking dog mounted in such a manner that it is free to rotate on a trunnion which is riveted to a locking...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Dog, swing. 236.743 Section 236.743 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.743 Dog, swing. A locking dog mounted in such a manner that it is free to rotate on a trunnion which is riveted to a locking...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Dog, swing. 236.743 Section 236.743 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.743 Dog, swing. A locking dog mounted in such a manner that it is free to rotate on a trunnion which is riveted to a locking...
77 FR 66703 - Safety Standard for Infant Swings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
.... Instability of the swing was reported in 5 percent of the incident reports. In most of these cases, the swing.... Nor is it necessarily easy for firms to estimate prospectively the economic impact that a regulation... of the likely economic impacts of conforming to the standard that is being proposed, not the economic...
The Kinetics of Swinging a Baseball Bat.
Crisco, Joseph J; Osvalds, Nikolas J; Rainbow, Michael J
2018-04-13
The purpose of this study was to compute the three-dimensional kinetics required to swing three youth baseball bats of varying moments of inertia (MOI). 306 swings by 22 male players (13-18 yrs.) were analyzed. Inverse dynamics with respect to the batter's hands were computed given the known kinematics and physical properties of the bats. We found that peak force increased with larger bat MOI and was strongly correlated with bat tip speed. In contrast, peak moments were weakly correlated with bat MOI and bat tip speed. Throughout the swing, the force applied to the bat was dominated by a component aligned with the long axis of the bat and directed away from the bat knob, while the moment applied to the bat was minimal until just prior to ball impact. These results indicate that players act to mostly "pull" the bat during their swing until just prior to ball impact, at which point they rapidly increase the moment on the bat. This kinetic analysis provides novel insight into the forces and moments used to swing baseball bats.
Pröbsting, Eva; Kannenberg, Andreas; Zacharias, Britta
2016-01-01
Background: There are clear indications for benefits of stance control orthoses compared to locked knee ankle foot orthoses. However, stance control orthoses still have limited function compared with a sound human leg. Objectives: The aim of this study was to evaluate the potential benefits of a microprocessor stance and swing control orthosis compared to stance control orthoses and locked knee ankle foot orthoses in activities of daily living. Study design: Survey of lower limb orthosis users before and after fitting of a microprocessor stance and swing control orthosis. Methods: Thirteen patients with various lower limb pareses completed a baseline survey for their current orthotic device (locked knee ankle foot orthosis or stance control orthosis) and a follow-up for the microprocessor stance and swing control orthosis with the Orthosis Evaluation Questionnaire, a new self-reported outcome measure devised by modifying the Prosthesis Evaluation Questionnaire for use in lower limb orthotics and the Activities of Daily Living Questionnaire. Results: The Orthosis Evaluation Questionnaire results demonstrated significant improvements by microprocessor stance and swing control orthosis use in the total score and the domains of ambulation (p = .001), paretic limb health (p = .04), sounds (p = .02), and well-being (p = .01). Activities of Daily Living Questionnaire results showed significant improvements with the microprocessor stance and swing control orthosis with regard to perceived safety and difficulty of activities of daily living. Conclusion: The microprocessor stance and swing control orthosis may facilitate an easier, more physiological, and safer execution of many activities of daily living compared to traditional leg orthosis technologies. Clinical relevance This study compared patient-reported outcomes of a microprocessor stance and swing control orthosis (C-Brace) to those with traditional knee ankle foot orthosis and stance control orthosis devices. The C-Brace offers new functions including controlled knee flexion during weight bearing and dynamic swing control, resulting in significant improvements in perceived orthotic mobility and safety. PMID:27151648
Pröbsting, Eva; Kannenberg, Andreas; Zacharias, Britta
2017-02-01
There are clear indications for benefits of stance control orthoses compared to locked knee ankle foot orthoses. However, stance control orthoses still have limited function compared with a sound human leg. The aim of this study was to evaluate the potential benefits of a microprocessor stance and swing control orthosis compared to stance control orthoses and locked knee ankle foot orthoses in activities of daily living. Survey of lower limb orthosis users before and after fitting of a microprocessor stance and swing control orthosis. Thirteen patients with various lower limb pareses completed a baseline survey for their current orthotic device (locked knee ankle foot orthosis or stance control orthosis) and a follow-up for the microprocessor stance and swing control orthosis with the Orthosis Evaluation Questionnaire, a new self-reported outcome measure devised by modifying the Prosthesis Evaluation Questionnaire for use in lower limb orthotics and the Activities of Daily Living Questionnaire. The Orthosis Evaluation Questionnaire results demonstrated significant improvements by microprocessor stance and swing control orthosis use in the total score and the domains of ambulation ( p = .001), paretic limb health ( p = .04), sounds ( p = .02), and well-being ( p = .01). Activities of Daily Living Questionnaire results showed significant improvements with the microprocessor stance and swing control orthosis with regard to perceived safety and difficulty of activities of daily living. The microprocessor stance and swing control orthosis may facilitate an easier, more physiological, and safer execution of many activities of daily living compared to traditional leg orthosis technologies. Clinical relevance This study compared patient-reported outcomes of a microprocessor stance and swing control orthosis (C-Brace) to those with traditional knee ankle foot orthosis and stance control orthosis devices. The C-Brace offers new functions including controlled knee flexion during weight bearing and dynamic swing control, resulting in significant improvements in perceived orthotic mobility and safety.
2012-03-22
this job exist outside the AF and there are benefits and drawbacks to military and civilian careers in the engineering field. What incentive do CE...like the AF at large doesnt appreciate my work anywhere. It’s personally disappointing, and somewhat depressing. It’s quite a pendulum swing from
A NASTRAN Model of a Large Flexible Swing-Wing Bomber. Volume 1: NASTRAN Model Plane
NASA Technical Reports Server (NTRS)
Mock, W. D.
1982-01-01
A review was conducted of B-1 aircraft no. 2 (A/C-2) internal loads models to determine the minimum model complexity necessary to fulfill all of the airloads research study objectives. Typical model sizings were tabulated at selected vehicle locations, and scale layouts were prepared of the NASTRAN structural analysis model.
Muscle activity during the golf swing.
McHardy, A; Pollard, H
2005-11-01
In the right hands, the golf swing is a motion that inspires looks of awe from the public. It is a complex movement of the whole body to generate power to a golf ball to propel the ball great distances with accuracy. This movement relies on the coordinated sequence of muscle activation to produce a fluid and reproducible movement. This paper reviews the literature on golf swing related muscle activity. The phases of this activity are discussed with a view to assisting the practitioner in understanding the swing. Such understanding may help in the management of the injured golfer.
Mood Swings: An Affective Interactive Art System
NASA Astrophysics Data System (ADS)
Bialoskorski, Leticia S. S.; Westerink, Joyce H. D. M.; van den Broek, Egon L.
The progress in the field of affective computing enables the realization of affective consumer products, affective games, and affective art. This paper describes the affective interactive art system Mood Swings, which interprets and visualizes affect expressed by a person. Mood Swings is founded on the integration of a framework for affective movements and a color model. This enables Mood Swings to recognize affective movement characteristics as expressed by a person and display a color that matches the expressed emotion. With that, a unique interactive system is introduced, which can be considered as art, a game, or a combination of both.
Sorbie, Graeme G; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike C
2018-04-01
The purpose of this study was to compare the electromyography (EMG) patterns of the thoracic and lumbar regions of the erector spinae (ES) muscle during the golf swing whilst using four different golf clubs. Fifteen right-handed male golfers performed a total of twenty swings in random order using the driver, 4-iron, 7-iron and pitching-wedge. Surface EMG was recorded from the lead and trail sides of the thoracic and lumbar regions of the ES muscle (T8, L1 and L5 lateral to the spinous-process). Three-dimensional high-speed video analysis was used to identify the backswing, forward swing, acceleration, early and late follow-through phases of the golf swing. No significant differences in muscle-activation levels from the lead and trail sides of the thoracic and lumbar regions of the ES muscle were displayed between the driver, 4-iron, 7-iron and pitching-wedge (P > 0.05). The highest mean thoracic and lumbar ES muscle-activation levels were displayed in the forward swing (67-99% MVC) and acceleration (83-106% MVC) phases of the swing for all clubs tested. The findings from this study show that there were no significant statistical differences between the driver, 4-iron, 7-iron and pitching-wedge when examining muscle activity from the thoracic and lumbar regions of the ES muscle.
Xu, Qiqi; Zhao, Jianwen; Pecunia, Vincenzo; Xu, Wenya; Zhou, Chunshan; Dou, Junyan; Gu, Weibing; Lin, Jian; Mo, Lixin; Zhao, Yanfei; Cui, Zheng
2017-04-12
The fabrication of printed high-performance and environmentally stable n-type single-walled carbon nanotube (SWCNT) transistors and their integration into complementary (i.e., complementary metal-oxide-semiconductor, CMOS) circuits are widely recognized as key to achieving the full potential of carbon nanotube electronics. Here, we report a simple, efficient, and robust method to convert the polarity of SWCNT thin-film transistors (TFTs) using cheap and readily available ethanolamine as an electron doping agent. Printed p-type bottom-gate SWCNT TFTs can be selectively converted into n-type by deposition of ethanolamine inks on the transistor active region via aerosol jet printing. Resulted n-type TFTs show excellent electrical properties with an on/off ratio of 10 6 , effective mobility up to 30 cm 2 V -1 s -1 , small hysteresis, and small subthreshold swing (90-140 mV dec -1 ), which are superior compared to the original p-type SWCNT devices. The n-type SWCNT TFTs also show good stability in air, and any deterioration of performance due to shelf storage can be fully recovered by a short low-temperature annealing. The easy polarity conversion process allows construction of CMOS circuitry. As an example, CMOS inverters were fabricated using printed p-type and n-type TFTs and exhibited a large noise margin (50 and 103% of 1/2 V dd = 1 V) and a voltage gain as high as 30 (at V dd = 1 V). Additionally, the CMOS inverters show full rail-to-rail output voltage swing and low power dissipation (0.1 μW at V dd = 1 V). The new method paves the way to construct fully functional complex CMOS circuitry by printed TFTs.
Stüeken, E E; Kipp, M A; Koehler, M C; Schwieterman, E W; Johnson, B; Buick, R
2016-12-01
Nitrogen is a major nutrient for all life on Earth and could plausibly play a similar role in extraterrestrial biospheres. The major reservoir of nitrogen at Earth's surface is atmospheric N 2 , but recent studies have proposed that the size of this reservoir may have fluctuated significantly over the course of Earth's history with particularly low levels in the Neoarchean-presumably as a result of biological activity. We used a biogeochemical box model to test which conditions are necessary to cause large swings in atmospheric N 2 pressure. Parameters for our model are constrained by observations of modern Earth and reconstructions of biomass burial and oxidative weathering in deep time. A 1-D climate model was used to model potential effects on atmospheric climate. In a second set of tests, we perturbed our box model to investigate which parameters have the greatest impact on the evolution of atmospheric pN 2 and consider possible implications for nitrogen cycling on other planets. Our results suggest that (a) a high rate of biomass burial would have been needed in the Archean to draw down atmospheric pN 2 to less than half modern levels, (b) the resulting effect on temperature could probably have been compensated by increasing solar luminosity and a mild increase in pCO 2 , and (c) atmospheric oxygenation could have initiated a stepwise pN 2 rebound through oxidative weathering. In general, life appears to be necessary for significant atmospheric pN 2 swings on Earth-like planets. Our results further support the idea that an exoplanetary atmosphere rich in both N 2 and O 2 is a signature of an oxygen-producing biosphere. Key Words: Biosignatures-Early Earth-Planetary atmospheres. Astrobiology 16, 949-963.
An improved correlation method for determining the period of a torsion pendulum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo Jie; Wang Dianhong
Considering variation of environment temperature and unhomogeneity of background gravitational field, an improved correlation method was proposed to determine the variational period of a torsion pendulum with high precision. The result of processing experimental data shows that the uncertainty of determining the period with this method has been improved about twofolds than traditional correlation method, which is significant for the determination of gravitational constant with time-of-swing method.
Lamb Wave Propagation in Varying Thermal Environments
2007-03-01
detection in structural joints (5). The Tacoma Narrows Bridge collapse, which occurred on 7 November 1940, was due to a torsional or twisting mode that...operational, the airframes can be subjected to temperature swings (-40°F to 150°F) and the corrosive effects of salts, de-icing agents, and several types...aircraft-grade aluminum plate study was used to verify wavespeed dispersion characteristics (7:428). Techniques similar to these are implemented in the
Extraction of Xenon Using Enriching Reflux Pressure Swing Adsorption
2010-09-01
collection scheme aimed at preconcentrating xenon without the use of any form of cooling. The collection scheme utilizes activated charcoal (AC), a... collection efficiency for a given trap size. For a given isothermal system, it can be seen that if adsorption occurs at high pressure, where capacity is... activated charcoal at room temperature. These results are presented below and show that these early tests appear very promising and that useful quantities
What Research Tells the Golf Instructor about the Golf Swing and Putting.
ERIC Educational Resources Information Center
Kraft, Robert E.
The purpose of this survey was to clarify some misconceptions and challenge some common practices in teaching golf skills. Over 100 research studies in golf have been reviewed and summarized. The following categories relating to the golf swing were examined: (1) grip; (2) videotape; (3) electronic golf swing analyzer; (4) teaching methods; (5)…
Movement Variability in the Golf Swing: Theoretical, Methodological, and Practical Issues
ERIC Educational Resources Information Center
Glazier, Paul
2011-01-01
Movement variability in the golf swing has recently been identified as a priority for future research in golf science. Although this ubiquitous aspect of golf performance has featured in previous empirical investigations of the golf swing, it has tended to be subordinate and studied as an adjunct to other more conventional research questions.…
The Effect of Restricted Arm Swing on Energy Expenditure in Healthy Men
ERIC Educational Resources Information Center
Yizhar, Ziva; Boulos, Spiro; Inbar, Omri; Carmeli, Eli
2009-01-01
Arm swing in human walking is an active natural motion involving the upper extremities. Earlier studies have described the interrelationship between arms and legs during walking, but the effect of arm swing on energy expenditure and dynamic parameters during normal gait, is inconclusive. The aim of this study was to investigate the effect of…
NASA Astrophysics Data System (ADS)
Allen, R. L.
2017-12-01
Enhanced images from subsea sonar scanning of the Western Gulf of Mexico have revealed quite large temples (4 km. in length), ruins of cities (14 km. by 11 km.), pyramids, amphitheaters, and many other structures. Some human faces have beards implying much earlier migrations of Europeans or North Africans. Several temples have paleo astronomy alignments and similarities to Stone Henge. Southern and Southwestern USA satellite land images display characteristics in common with several subsea designs. Water depths indicate that many structures go back about as far as the late Ice Age and are likely to be over ten thousand years old. Chronologies of civilizations, especially in North America will need to be seriously reconsidered. Greatly rising sea levels and radical climate changes must have helped to destroy relatively advanced cultures. Suprisingly deep water depths of many architectures provide evidence for closures within the Gulf of Mexico to open seas. Closures and openings may have influenced ancient radical climate swings between warmth and cooling as Gulf contributions to water temperatures contracted or expanded. These creations of very old and surprisingly advanced civilizations need protection.
Bipolar correlation of volcanism with millennial climate change
Bay, Ryan C.; Bramall, Nathan; Price, P. Buford
2004-01-01
Analyzing data from our optical dust logger, we find that volcanic ash layers from the Siple Dome (Antarctica) borehole are simultaneous (with >99% rejection of the null hypothesis) with the onset of millennium-timescale cooling recorded at Greenland Ice Sheet Project 2 (GISP2; Greenland). These data are the best evidence yet for a causal connection between volcanism and millennial climate change and lead to possibilities of a direct causal relationship. Evidence has been accumulating for decades that volcanic eruptions can perturb climate and possibly affect it on long timescales and that volcanism may respond to climate change. If rapid climate change can induce volcanism, this result could be further evidence of a southern-lead North–South climate asynchrony. Alternatively, a volcanic-forcing viewpoint is of particular interest because of the high correlation and relative timing of the events, and it may involve a scenario in which volcanic ash and sulfate abruptly increase the soluble iron in large surface areas of the nutrient-limited Southern Ocean, stimulate growth of phytoplankton, which enhance volcanic effects on planetary albedo and the global carbon cycle, and trigger northern millennial cooling. Large global temperature swings could be limited by feedback within the volcano–climate system. PMID:15096586
Experimental and numerical study of a dual configuration for a flapping tidal current generator.
Kim, Jihoon; Quang Le, Tuyen; Hwan Ko, Jin; Ebenezer Sitorus, Patar; Hartarto Tambunan, Indra; Kang, Taesam
2015-07-30
In this study, we conduct experimental and consecutive numerical analyses of a flapping tidal current generator with a mirror-type dual configuration with front-swing and rear-swing flappers. An experimental analysis of a small-scale prototype is conducted in a towing tank, and a numerical analysis is conducted by means of two-dimensional computational fluid dynamics simulations with an in-house code. An experimental study with a controller to determine the target arm angle shows that the resultant arm angle is dependent on the input arm angle, the frequency, and the applied load, while a high pitch is obtained simply with a high input arm angle. Through a parametric analysis conducted while varying these factors, a high applied load and a high input arm angle were found to be advantageous. Moreover, the optimal reduced frequency was found to be 0.125 in terms of the power extraction. In consecutive numerical investigations with the kinematics selected from the experiments, it was found that a rear-swing flapper contributes to the total amount of power more than a front-swing flapper with a distance of two times the chord length and with a 90° phase difference between the two. The high contribution stems from the high power generated by the rear-swing flapper, which mimics the tail fin movement of a dolphin along a flow, compared to a plunge system or a front-swing system, which mimics the tail fin movement of a dolphin against a flow. It is also due to the fact that the shed vorticities of the front-swing flapper slightly affect negatively or even positively the power performance of the rear-swing system at a given distance and phase angle.
Arm swing as a potential new prodromal marker of Parkinson's disease.
Mirelman, Anat; Bernad-Elazari, Hagar; Thaler, Avner; Giladi-Yacobi, Eytan; Gurevich, Tanya; Gana-Weisz, Mali; Saunders-Pullman, Rachel; Raymond, Deborah; Doan, Nancy; Bressman, Susan B; Marder, Karen S; Alcalay, Roy N; Rao, Ashwini K; Berg, Daniela; Brockmann, Kathrin; Aasly, Jan; Waro, Bjørg Johanne; Tolosa, Eduardo; Vilas, Dolores; Pont-Sunyer, Claustre; Orr-Urtreger, Avi; Hausdorff, Jeffrey M; Giladi, Nir
2016-10-01
Reduced arm swing is a well-known clinical feature of Parkinson's disease (PD), often observed early in the course of the disease. We hypothesized that subtle changes in arm swing and axial rotation may also be detectable in the prodromal phase. The purpose of this study was to evaluate the relationship between the LRRK2-G2019S mutation, arm swing, and axial rotation in healthy nonmanifesting carriers and noncarriers of the G2019S mutation and in patients with PD. A total of 380 participants (186 healthy nonmanifesting controls and 194 PD patients) from 6 clinical sites underwent gait analysis while wearing synchronized 3-axis body-fixed sensors on the lower back and bilateral wrists. Participants walked for 1 minute under the following 2 conditions: (1) usual walking and (2) dual-task walking. Arm swing amplitudes, asymmetry, variability, and smoothness were calculated for both arms along with measures of axial rotation. A total of 122 nonmanifesting participants and 67 PD patients were carriers of the G2019S mutation. Nonmanifesting mutation carriers walked with greater arm swing asymmetry and variability and lower axial rotation smoothness under the dual task condition when compared with noncarriers (P < .04). In the nonmanifesting mutation carriers, arm swing asymmetry was associated with gait variability under dual task (P = .003). PD carriers showed greater asymmetry and variability of movement than PD noncarriers, even after controlling for disease severity (P < .009). The G2019S mutation is associated with increased asymmetry and variability among nonmanifesting participants and patients with PD. Prospective studies should determine if arm swing asymmetry and axial rotation smoothness may be used as motor markers of prodromal PD. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
Thompson, Elizabeth; Agada, Peter; Wright, W Geoffrey; Reimann, Hendrik; Jeka, John
2017-10-01
Impaired arm swing is a common motor symptom of Parkinson's disease (PD), and correlates with other gait impairments and increased risk of falls. Studies suggest that arm swing is not merely a passive consequence of trunk rotation during walking, but an active component of gait. Thus, techniques to enhance arm swing may improve gait characteristics. There is currently no portable device to measure arm swing and deliver immediate cues for larger movement. Here we test report pilot testing of such a device, ArmSense (patented), using a crossover repeated-measures design. Twelve people with PD walked in a video-recorded gym space at self-selected comfortable and fast speeds. After baseline, cues were given either visually using taped targets on the floor to increase step length or through vibrations at the wrist using ArmSense to increase arm swing amplitude. Uncued walking then followed, to assess retention. Subjects successfully reached cueing targets on >95% of steps. At a comfortable pace, step length increased during both visual cueing and ArmSense cueing. However, we observed increased medial-lateral trunk sway with visual cueing, possibly suggesting decreased gait stability. In contrast, no statistically significant changes in trunk sway were observed with ArmSense cues compared to baseline walking. At a fast pace, changes in gait parameters were less systematic. Even though ArmSense cues only specified changes in arm swing amplitude, we observed changes in multiple gait parameters, reflecting the active role arm swing plays in gait and suggesting a new therapeutic path to improve mobility in people with PD. Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of proton irradiated n- and p-type strained FinFETs at low temperatures down to 100 K
NASA Astrophysics Data System (ADS)
Vicentis Caparroz, Luis Felipe; Mendes Bordallo, Caio Cesar; Martino, Joao Antonio; Simoen, Eddy; Claeys, Cor; Ghedini Der Agopian, Paula
2018-06-01
This paper studies the main low temperature electrical parameters of SOI n- and p-type FinFETs, standard and strained devices, submitted to proton irradiation. The study covers the range from room temperature down to 100 K, focusing on the threshold voltage (VTH), subthreshold swing (SS), the Early voltage VEA, transistor efficiency and the intrinsic gain voltage (AV) for 3 different channel widths. The p-channel devices showed a greater immunity to radiation than the n-channel ones, when considering the basic parameters thanks to the back conduction turn-off tendency, while from the analog parameters point of view, both transistor types presented a similar response to proton radiation at strong inversion.
Andrysek, Jan; Chau, Gilbert
2007-12-01
Microprocessor-controlled prostheses facilitate a more natural and efficient gait for individuals with above-knee amputations by continually adjusting the level of swing-phase damping. One caveat associated with these technologies is that the user must charge the onboard batteries on a daily basis. It is, therefore, the aim of this study to examine the feasibility of using an electromechanical system to provide prosthetic swing-phase damping and, concomitantly, the function of converting physiological energy that is normally dissipated during the swing phase, to electrical energy. Gait data from a single subject and data from a kinematic simulator were used to develop an empirical model. The findings in this study indicate that an electromagnetic system has appropriate characteristics for use in swing-phase control and also has the potential to recover energy under particular conditions.
NASA Astrophysics Data System (ADS)
Sakai, Naoki; Kawabe, Naoto; Hara, Masayuki; Toyoda, Nozomi; Yabuta, Tetsuro
This paper argues how a compact humanoid robot can acquire a giant-swing motion without any robotic models by using Q-Learning method. Generally, it is widely said that Q-Learning is not appropriated for learning dynamic motions because Markov property is not necessarily guaranteed during the dynamic task. However, we tried to solve this problem by embedding the angular velocity state into state definition and averaging Q-Learning method to reduce dynamic effects, although there remain non-Markov effects in the learning results. The result shows how the robot can acquire a giant-swing motion by using Q-Learning algorithm. The successful acquired motions are analyzed in the view point of dynamics in order to realize a functionally giant-swing motion. Finally, the result shows how this method can avoid the stagnant action loop at around the bottom of the horizontal bar during the early stage of giant-swing motion.
To develop behavioral tests of vestibular functioning in the Wistar rat
NASA Technical Reports Server (NTRS)
Nielson, H. C.
1980-01-01
Two tests of vestibular functioning in the rat were developed. The first test was the water maze. In the water maze the rat does not have the normal proprioceptive feedback from its limbs to help it maintain its orientation, and must rely primarily on the sensory input from its visual and vestibular systems. By altering lighting conditions and visual cues the vestibular functioning without visual cues was assessed. Whether there was visual compensation for some vestibular dysfunction was determined. The second test measured vestibular functioning of the rat's behavior on a parallel swing. In this test the rat's postural adjustments while swinging on the swing with the otoliths being stimulated were assessed. Less success was achieved in developing the parallel swing as a test of vestibular functioning than with the water maze. The major problem was incorrect initial assumptions of what the rat's probable behavior on the parallel swing would be.
A glider swing intervention for people with dementia.
Snyder, M; Tseng, Y; Brandt, C; Croghan, C; Hanson, S; Constantine, R; Kirby, L
2001-01-01
The soothing, repetitive movement of rocking and swinging is well known to anyone who has enjoyed a porch swing or rocking chair. Positive effects of rocking have been reported. However, investigations on its effect in people with dementia are limited. The purposes of this quasi-experimental, repeated-measures design study were to measure the effects of a glider swing on emotions, relaxation, and aggressive behaviors in a group of nursing home residents with dementia (n = 30). Data were obtained during a 5-day baseline phase, a 10-day intervention phase, and a 5-day posttreatment phase. Subjects were placed on the glider for 20 minutes each day during the intervention phase. The results of the study indicate that the glider intervention significantly improved emotions and relaxation. The most noted changes were found after 10 minutes of swinging. However, no differences were found in aggressive behaviors.
Nanopatterning of swinging substrates by ion-beam sputtering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Sun Mi; Kim, J.-S., E-mail: jskim@sm.ac.kr
Graphite substrates are azimuthally swung during ion-beam sputtering (IBS) at a polar angle θ = 78° from the surface normal. The swinging of the substrate not only causes quasi-two-dimensional mass transport but also makes various sputter effects from the different incident angles to work together. Through variation of the swing angle, both the transport and sputtering effects synergistically produce a series of salient patterns, such as asymmetric wall-like structures, which can grow to several tens of nanometers and exhibit a re-entrant orientational change with the increased swing angle. Thus, the present work demonstrates that dynamic variables such as the swing angle, whichmore » have been little utilized, offer an additional parameter space that can be exploited to diversify the sputtered patterns, thereby expanding the applicability of an IBS as well as the comprehension of the IBS nano patterning mechanism.« less
Everaerts, Ken; Zeng, Li; Hennek, Jonathan W; Camacho, Diana I; Jariwala, Deep; Bedzyk, Michael J; Hersam, Mark C; Marks, Tobin J
2013-11-27
Solution-processed amorphous oxide semiconductors (AOSs) are emerging as important electronic materials for displays and transparent electronics. We report here on the fabrication, microstructure, and performance characteristics of inkjet-printed, low-temperature combustion-processed, amorphous indium gallium zinc oxide (a-IGZO) thin-film transistors (TFTs) grown on solution-processed hafnia self-assembled nanodielectrics (Hf-SANDs). TFT performance for devices processed below 300 °C includes >4× enhancement in electron mobility (μFE) on Hf-SAND versus SiO2 or ALD-HfO2 gate dielectrics, while other metrics such as subthreshold swing (SS), current on:off ratio (ION:IOFF), threshold voltage (Vth), and gate leakage current (Ig) are unchanged or enhanced. Thus, low voltage IGZO/SAND TFT operation (<2 V) is possible with ION:IOFF = 10(7), SS = 125 mV/dec, near-zero Vth, and large electron mobility, μFE(avg) = 20.6 ± 4.3 cm(2) V(-1) s(-1), μFE(max) = 50 cm(2) V(-1) s(-1). Furthermore, X-ray diffraction analysis indicates that the 300 °C IGZO combustion processing leaves the underlying Hf-SAND microstructure and capacitance intact. This work establishes the compatibility and advantages of all-solution, low-temperature fabrication of inkjet-printed, combustion-derived high-mobility IGZO TFTs integrated with self-assembled hybrid organic-inorganic nanodielectrics.
IGZO TFT-based circuit with tunable threshold voltage by laser annealing
NASA Astrophysics Data System (ADS)
Huang, Xiaoming; Yu, Guang; Wu, Chenfei
2017-11-01
In this work, a high-performance inverter based on amorphous indium-gallium-zinc oxide thin-film transistors (TFTs) has been fabricated, which consists of a driver TFT and a load TFT. The threshold voltage (Vth) of the load TFT can be tuned by applying an area-selective laser annealing. The transfer curve of the load TFT shows a parallel shift into the negative bias direction upon laser annealing. Based on x-ray photoelectron spectroscopy analyses, the negative Vth shift can be attributed to the increase of oxygen vacancy concentration within the device channel upon laser irradiation. Compared to the untreated inverter, the laser annealed inverter shows much improved switching characteristics, including a large output swing range which is close to full swing, as well as an enhanced output voltage gain. Furthermore, the dynamic performance of ring oscillator based on the laser-annealed inverter is improved.
A passively controlled appendage deployment system for the San Marco D/L spacecraft
NASA Technical Reports Server (NTRS)
Lang, W. E.; Frisch, H. P.; Schwartz, D. A.
1984-01-01
The analytical simulation of deployment dynamics of these two axis concepts as well as the evolution of practical designs for the add on deployable inertia boom units is described. With the boom free to swing back in response to Coriolis forces as well as outwards in response to centrifugal forces, the kinematics of motion are complex but admit the possibility of absorbing deployment energy in frictional or other damping devices about the radial axis, where large amplitude motions can occur and where the design envelope allows more available volume. An acceptable range is defined for frictional damping for any given spin rate. Inadequate damping allows boom motions which strike the spacecraft; excessive damping causes the boom to swing out and latch with damaging violence. The acceptable range is a design parameter and must accommodate spin rate tolerance and also the tolerance and repeatability of the damping mechanisms.
Polarization swings reveal magnetic energy dissipation in blazars
Zhang, Haocheng; Chen, Xuhui; Böttcher, Markus; ...
2015-05-01
The polarization signatures of blazar emissions are known to be highly variable. In addition to small fluctuations of the polarization angle around a mean value, large (≳ 180°) polarization angle swings are observed. We suggest that such phenomena can be interpreted as arising from light-travel-time effects within an underlying axisymmetric emission region. We present the first simultaneous fitting of the multi-wavelength spectrum, variability, and time-dependent polarization features of a correlated optical and gamma-ray flaring event of the prominent blazar 3C279, which was accompanied by a drastic change in its polarization signatures. This unprecedented combination of spectral, variability, and polarization informationmore » in a coherent physical model allows us to place stringent constraints on the particle acceleration and magnetic-field topology in the relativistic jet of a blazar, strongly favoring a scenario in which magnetic energy dissipation is the primary driver of the flare event.« less
Swing arm profilometer: analytical solutions of misalignment errors for testing axisymmetric optics
NASA Astrophysics Data System (ADS)
Xiong, Ling; Luo, Xiao; Liu, Zhenyu; Wang, Xiaokun; Hu, Haixiang; Zhang, Feng; Zheng, Ligong; Zhang, Xuejun
2016-07-01
The swing arm profilometer (SAP) has been playing a very important role in testing large aspheric optics. As one of most significant error sources that affects the test accuracy, misalignment error leads to low-order errors such as aspherical aberrations and coma apart from power. In order to analyze the effect of misalignment errors, the relation between alignment parameters and test results of axisymmetric optics is presented. Analytical solutions of SAP system errors from tested mirror misalignment, arm length L deviation, tilt-angle θ deviation, air-table spin error, and air-table misalignment are derived, respectively; and misalignment tolerance is given to guide surface measurement. In addition, experiments on a 2-m diameter parabolic mirror are demonstrated to verify the model; according to the error budget, we achieve the SAP test for low-order errors except power with accuracy of 0.1 μm root-mean-square.
NASA Astrophysics Data System (ADS)
Lin, Jianqiang; Kim, Tae-Woo; Antoniadis, Dimitri A.; del Alamo, Jesús A.
2012-06-01
We present a novel n-type InGaAs quantum-well metal-oxide-semiconductor field-effect transistor (QW-MOSFET) fabricated by a self-aligned gate-last process and investigate relevant Si-like manufacturing issues in future III-V MOSFETs. The device structure features a composite InP/Al2O3 gate barrier with a capacitance equivalent thickness (CET) of 3 nm and non alloyed Mo ohmic contacts. We have found that RIE introduces significant damage to the intrinsic device resulting in poor current drive and subthreshold swing. The effect is largely removed through a thermal annealing step. Thermally annealed QW-MOSFETs exhibit a subthreshold swing of 95 mV/dec, indicative of excellent interfacial characteristics. The peak mobility of the MOSFET is 2780 cm2 V-1 s-1.
Breakthrough in Xenon Capture and Purification Using Adsorbent-Supported Silver Nanoparticles.
Deliere, Ludovic; Coasne, Benoit; Topin, Sylvain; Gréau, Claire; Moulin, Christophe; Farrusseng, David
2016-07-04
Rare gas capture and purification is a major challenge for energy, environment, and health applications. Of utmost importance for the nuclear industry, novel separation processes for Xe are urgently needed for spent nuclear fuel reprocessing and nuclear activity monitoring. The recovered, non-radioactive Xe is also of high economic value for lighting, surgical anesthetic, etc. Here, using adsorption and breakthrough experiments and statistical mechanics molecular simulation, we show the outstanding performance of zeolite-supported silver nanoparticles to capture/separate Xe at low concentrations (0.087-100 ppm). We also establish the efficiency of temperature swing adsorption based on such adsorbents for Xe separation from Kr/Xe mixtures and air streams corresponding to off-gases generated by nuclear reprocessing. This study paves the way for the development of novel, cost-efficient technologies relying on the large selectivity/capacity of adsorbent-supported silver nanoparticles which surpass all materials ever tested. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The Effects of an Ergogenic Aid on Golf Swing Consistency and Skill.
ERIC Educational Resources Information Center
Moore, John O.; Beitel, Patricia A.
Golf experts suggest that a performer should attempt to swing the same way during each shot, changing clubs to alter the flight trajectory and distance of the ball. This study sought to determine if there was a difference in the development of golf skill and swing consistency between a control group and an experimental group using an ergogenic…
How Do Batters Use Visual, Auditory, and Tactile Information about the Success of a Baseball Swing?
ERIC Educational Resources Information Center
Gray, Rob
2009-01-01
Bat/ball contact produces visual (the ball leaving the bat), auditory (the "crack" of the bat), and tactile (bat vibration) feedback about the success of the swing. We used a batting simulation to investigate how college baseball players use visual, tactile, and auditory feedback. In Experiment 1, swing accuracy (i.e., the lateral separation…
Control of Angular Momentum during Walking in Children with Cerebral Palsy
ERIC Educational Resources Information Center
Bruijn, Sjoerd M.; Meyns, Pieter; Jonkers, Ilse; Kaat, Desloovere; Duysens, Jacques
2011-01-01
Children with hemiparetic Cerebral Palsy (CP) walk with marked asymmetries. For instance, we have recently shown that they have less arm swing on the affected side, and more arm swing at the unaffected side. Such an increase in arm swing at the unaffected side may be aimed at controlling total body angular momentum about the vertical axis,…
Franz-Keldysh effect in GeSn pin photodetectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oehme, M., E-mail: oehme@iht.uni-stuttgart.de; Kostecki, K.; Schmid, M.
2014-04-21
The optical properties and the Franz-Keldysh effect at the direct band gap of GeSn alloys with Sn concentrations up to 4.2% at room temperature were investigated. The GeSn material was embedded in the intrinsic region of a Ge heterojunction photodetector on Si substrates. The layer structure was grown by means of ultra-low temperature molecular beam epitaxy. The absorption coefficient as function of photon energy and the direct bandgap energies were determined. In all investigated samples, the Franz-Keldysh effect can be observed. A maximum absorption ratio of 1.5 was determined for 2% Sn for a voltage swing of 3 V.
Detailed view of one (1) end of the swing span, ...
Detailed view of one (1) end of the swing span, supported on a rest pier, with the span in the closed position and in the train operational mode. Note the end truss bearing where a steel wedge is in the driven position to complete the end bearing arrangement. The wedges are power-driven through the machinery crank arms shown, thus forcing the ends of the swing span truss upward. Note: The top of the old stone pies has been encased with a concrete collar to hold stone masonry together and strengthen truss bearing points. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
A new concept in denture design for patients with few remaining teeth: case reports.
Ling, B C
1995-12-01
This article presents an alternative to the conventional swing-lock de sign of removable partial denture construction. It incorporates the principles of sectional dentures as well as the swing-lock concept and overcomes some of the limitations of conventional swing-lock dentures. I-bar struts and stainless steel keepers form part of the first section of the denture. The second part of the denture consists of the denture base with the artificial teeth and magnetic retention units. This system has been used successfully in a number of patients whose situations were suitable for the conventional swing-lock design.
Increasing cognitive load attenuates right arm swing in healthy human walking
NASA Astrophysics Data System (ADS)
Killeen, Tim; Easthope, Christopher S.; Filli, Linard; Lőrincz, Lilla; Schrafl-Altermatt, Miriam; Brugger, Peter; Linnebank, Michael; Curt, Armin; Zörner, Björn; Bolliger, Marc
2017-01-01
Human arm swing looks and feels highly automated, yet it is increasingly apparent that higher centres, including the cortex, are involved in many aspects of locomotor control. The addition of a cognitive task increases arm swing asymmetry during walking, but the characteristics and mechanism of this asymmetry are unclear. We hypothesized that this effect is lateralized and a Stroop word-colour naming task-primarily involving left hemisphere structures-would reduce right arm swing only. We recorded gait in 83 healthy subjects aged 18-80 walking normally on a treadmill and while performing a congruent and incongruent Stroop task. The primary measure of arm swing asymmetry-an index based on both three-dimensional wrist trajectories in which positive values indicate proportionally smaller movements on the right-increased significantly under dual-task conditions in those aged 40-59 and further still in the over-60s, driven by reduced right arm flexion. Right arm swing attenuation appears to be the norm in humans performing a locomotor-cognitive dual-task, confirming a prominent role of the brain in locomotor behaviour. Women under 60 are surprisingly resistant to this effect, revealing unexpected gender differences atop the hierarchical chain of locomotor control.
Electromyographic Analysis of the Lower Limb Muscles in Low- and High-Handicap Golfers.
Marta, Sérgio; Silva, Luís; Vaz, João R; Castro, Maria António; Reinaldo, Gustavo; Pezarat-Correia, Pedro
2016-09-01
The aim of this study was to compare the electromyographic patterns of the lower limb muscles during a golf swing performed by low- and high-handicap golfers. Ten golfers (5 low- and 5 high-handicap) performed 8 swings using a 7-iron. Surface electromyography (EMG) was recorded for the following lower limb muscles on both sides: biceps femoris, semitendinosus, gluteus maximus, vastus medialis and lateralis, rectus femoris, tibialis anterior, peroneus longus, and gastrocnemius medialis and lateralis. The golf-swing phases were determined by 3-dimensional high-speed video analysis. Compared with the high-handicap golfers, the low-handicap golfers performed the forward swing with a shorter duration of the swing phases, with the exception of the late follow-through, where they exhibited longer duration. Considering the EMG patterns, the low-handicap golfers showed a tendency for the studied muscles to reach an activation peak earlier and presented statistically significant higher muscle activity in some of the lower limb muscles, mainly from the left side. Differences between low- and high-handicap golfers were found in the average duration of swing phases and in the activation level of the lower limbs, with more evidence on muscles from the left side.
Relationships between clubshaft motions and clubface orientation during the golf swing.
Takagi, Tokio; Yokozawa, Toshiharu; Inaba, Yuki; Matsuda, Yuji; Shiraki, Hitoshi
2017-09-01
Since clubface orientation at impact affects ball direction and ball spin, the ability to control clubface orientation is one of the most important skills for golfers. This study presents a new method to describe clubface orientation as a function of the clubshaft motions (i.e., swing plane orientation, clubshaft angle in the swing plane, and clubshaft rolling angle) during a golf swing and investigates the relationships between the clubshaft motions and clubface orientation at impact. The club motion data of driver shots were collected from eight skilled golfers using a three-dimensional motion capture system. The degrees of influence of the clubshaft motions on the clubface orientation were investigated using sensitivity analysis. The sensitivity analysis revealed that the swing plane horizontal angle affected the clubface horizontal angle to an extent of 100%, that the clubshaft angle in the swing plane affected both the clubface vertical and horizontal angles to extents of 74 and 68%, respectively, and that the clubshaft rolling angle affected both the clubface vertical and horizontal angles to extents of -67 and 75%, respectively. Since the method presented here relates clubface orientation to clubshaft motions, it is useful for understanding the clubface control of a golfer.
Effect of different external attention of focus instruction on learning of golf putting skill.
Shafizadeh, Mohsen; McMorris, Terry; Sproule, John
2011-10-01
The effect of different sources of external attentional focus on learning a motor skill was assessed in the present study. 30 students (12 men, 18 women) participated voluntarily and were divided, according to type of external focus, into target, club swing, and target-club swing groups. The task was a golf putting skill. The target focus group attended to the target (hole), the club swing focus group attended to the execution of the club's swing, and the target-club swing focus group attended to both. All participants performed 50 trials of the putting skill in the acquisition phase and 10 trials in the 24-hr. delayed retention phase. The dependent variable was the error in the putting skill measured as the distance from the hole to the ball after each strike. Results showed the target-club swing focus group had better scores in the acquisition and retention phases than the other groups. It was concluded that external focus instruction helped the learners to integrate target cue with action cue and is more effective in skill learning than other external-focus instructions. These results support the claims of ecological psychology theorists concerning the effects of external focus of attention.
[Recognition of walking stance phase and swing phase based on moving window].
Geng, Xiaobo; Yang, Peng; Wang, Xinran; Geng, Yanli; Han, Yu
2014-04-01
Wearing transfemoral prosthesis is the only way to complete daily physical activity for amputees. Motion pattern recognition is important for the control of prosthesis, especially in the recognizing swing phase and stance phase. In this paper, it is reported that surface electromyography (sEMG) signal is used in swing and stance phase recognition. sEMG signal of related muscles was sampled by Infiniti of a Canadian company. The sEMG signal was then filtered by weighted filtering window and analyzed by height permitted window. The starting time of stance phase and swing phase is determined through analyzing special muscles. The sEMG signal of rectus femoris was used in stance phase recognition and sEMG signal of tibialis anterior is used in swing phase recognition. In a certain tolerating range, the double windows theory, including weighted filtering window and height permitted window, can reach a high accuracy rate. Through experiments, the real walking consciousness of the people was reflected by sEMG signal of related muscles. Using related muscles to recognize swing and stance phase is reachable. The theory used in this paper is useful for analyzing sEMG signal and actual prosthesis control.
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong
2018-01-01
Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.
Stepping responses to treadmill perturbations vary with severity of motor deficits in human SCI.
Chu, Virginia Way Tong; Hornby, T George; Schmit, Brian D
2018-04-18
In this study, we investigated the responses to tread perturbations during human stepping on a treadmill. Our approach was to test the effects of perturbations to a single leg using a split-belt treadmill in healthy participants and in participants with varying severity of spinal cord injury (SCI). We recruited 11 people with incomplete SCI and 5 noninjured participants. As participants walked on an instrumented treadmill, the belt on one side was stopped or accelerated briefly during mid to late stance. A majority of participants initiated an unnecessary swing when the treadmill was stopped in mid stance, although the likelihood of initiating a step was decreased in participants with more severe SCI. Accelerating or decelerating one belt of the treadmill during stance altered the characteristics of swing. We observed delayed swing initiation when the belt was decelerated (i.e. the hip was in a more flexed position at time of swing) and advanced swing initiation with acceleration (i.e. hip extended at swing initiation). Further, the timing and leg posture of heel strike appeared to remain constant, reflected by a sagittal plane hip angle at heel strike that remained the same regardless of the perturbation. In summary, our results supported the current understanding of the role of sensory feedback and central drive in the control of stepping in participants with incomplete SCI and noninjured participants. In particular, the observation of unnecessary swing during a stop perturbation highlights the interdependence of central and sensory drive in walking control.
29 CFR Appendix E to Subpart M of... - Sample Fall Protection Plan
Code of Federal Regulations, 2012 CFR
2012-07-01
... system shall not be used when the wind is strong enough to cause loads with large surface areas to swing out of radius, or result in loss of control of the load, or when weather conditions cause the walking... column is through the slab opening, there will no longer exist a fall hazard at this location. III...
29 CFR Appendix E to Subpart M of... - Sample Fall Protection Plan
Code of Federal Regulations, 2013 CFR
2013-07-01
... system shall not be used when the wind is strong enough to cause loads with large surface areas to swing out of radius, or result in loss of control of the load, or when weather conditions cause the walking... column is through the slab opening, there will no longer exist a fall hazard at this location. III...
29 CFR Appendix E to Subpart M of... - Sample Fall Protection Plan
Code of Federal Regulations, 2011 CFR
2011-07-01
... system shall not be used when the wind is strong enough to cause loads with large surface areas to swing out of radius, or result in loss of control of the load, or when weather conditions cause the walking... column is through the slab opening, there will no longer exist a fall hazard at this location. III...
ERIC Educational Resources Information Center
Dyson, Dana D.
2009-01-01
Reforms in American public education have not resolved the wide academic performance gap between students attending schools in poor, large, urban centers versus schools in wealthier areas. Aggregate performance outcomes on state achievement tests reveal that some school districts consistently outperform others, a few fluctuate over time but are…
High-pressure swing system for measurements of radioactive fission gases in air samples
NASA Astrophysics Data System (ADS)
Schell, W. R.; Vives-Battle, J.; Yoon, S. R.; Tobin, M. J.
1999-01-01
Radionuclides emitted from nuclear reactors, fuel reprocessing facilities and nuclear weapons tests are distributed widely in the atmosphere but have very low concentrations. As part of the Comprehensive Test Ban Treaty (CTBT), identification and verification of the emission of radionuclides from such sources are fundamental in maintaining nuclear security. To detect underground and underwater nuclear weapons tests, only the gaseous components need to be analyzed. Equipment has now been developed that can be used to collect large volumes of air, separate and concentrate the radioactive gas constituents, such as xenon and krypton, and measure them quantitatively. By measuring xenon isotopes with different half-lives, the time since the fission event can be determined. Developments in high-pressure (3500 kPa) swing chromatography using molecular sieve adsorbents have provided the means to collect and purify trace quantities of the gases from large volumes of air automatically. New scintillation detectors, together with timing and pulse shaping electronics, have provided the low-background levels essential in identifying the gamma ray, X-ray, and electron energy spectra of specific radionuclides. System miniaturization and portability with remote control could be designed for a field-deployable production model.
Frequency Shift During Mass Properties Testing Using Compound Pendulum Method
NASA Technical Reports Server (NTRS)
Wolfe, David; Regan, Chris
2012-01-01
During mass properties testing on the X-48B Blended Wing Body aircraft (The Boeing Company, Chicago, Illinois) at the National Aeronautics and Space Administration Dryden Flight Research Center, Edwards, California, large inertia measurement errors were observed in results from compound pendulum swings when compared to analytical models. By comparing periods of oscillations as measured from an average over the test period versus the period of each oscillation, it was noticed that the frequency of oscillation was shifting significantly throughout the test. This phenomenon was only noticed during compound pendulum swings, and not during bifilar pendulum swings. The frequency shift was only visible upon extensive data analysis of the frequency for each oscillation, and did not appear in averaged frequency data over the test period. Multiple test articles, test techniques, and hardware setups were used in attempts to eliminate or identify the cause of the frequency shift. Plotting the frequency of oscillation revealed a region of minimal shift that corresponded to a larger amplitude range. This region of minimal shift provided the most accurate results compared to a known test article; however, the amplitudes that produce accurate inertia measurements are amplitudes larger than those generally accepted in mass properties testing. This paper examines two case studies of the frequency shift, using mass properties testing performed on a dummy test article, and on the X-48B Blended Wing Body aircraft.
Detailed view of one (1) arm of the swing bridge ...
Detailed view of one (1) arm of the swing bridge cantilevering out from the center/pivot pier on which the entire span is balanced at its center when in the open position. Both arms of the span have equal length. Note that the members are pin-connected at their connections (joints). - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Silicon-On-Insulator (SOI) Devices and Mixed-Signal Circuits for Extreme Temperature Applications
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad; Elbuluk, Malik
2008-01-01
Electronic systems in planetary exploration missions and in aerospace applications are expected to encounter extreme temperatures and wide thermal swings in their operational environments. Electronics designed for such applications must, therefore, be able to withstand exposure to extreme temperatures and to perform properly for the duration of the missions. Electronic parts based on silicon-on-insulator (SOI) technology are known, based on device structure, to provide faster switching, consume less power, and offer better radiation-tolerance compared to their silicon counterparts. They also exhibit reduced current leakage and are often tailored for high temperature operation. However, little is known about their performance at low temperature. The performance of several SOI devices and mixed-signal circuits was determined under extreme temperatures, cold-restart, and thermal cycling. The investigations were carried out to establish a baseline on the functionality and to determine suitability of these devices for use in space exploration missions under extreme temperatures. The experimental results obtained on selected SOI devices are presented and discussed in this paper.
Operator control systems and methods for swing-free gantry-style cranes
Feddema, J.T.; Petterson, B.J.; Robinett, R.D. III
1998-07-28
A system and method are disclosed for eliminating swing motions in gantry-style cranes while subject to operator control. The present invention comprises an infinite impulse response (IIR) filter and a proportional-integral (PI) feedback controller. The IIR filter receives input signals (commanded velocity or acceleration) from an operator input device and transforms them into output signals in such a fashion that the resulting motion is swing free (i.e., end-point swinging prevented). The parameters of the IIR filter are updated in real time using measurements from a hoist cable length encoder. The PI feedback controller compensates for modeling errors and external disturbances, such as wind or perturbations caused by collision with objects. The PI feedback controller operates on cable swing angle measurements provided by a cable angle sensor. The present invention adjusts acceleration and deceleration to eliminate oscillations. An especially important feature of the present invention is that it compensates for variable-length cable motions from multiple cables attached to a suspended payload. 10 figs.
Operator control systems and methods for swing-free gantry-style cranes
Feddema, John T.; Petterson, Ben J.; Robinett, III, Rush D.
1998-01-01
A system and method for eliminating swing motions in gantry-style cranes while subject to operator control is presented. The present invention comprises an infinite impulse response ("IIR") filter and a proportional-integral ("PI") feedback controller (50). The IIR filter receives input signals (46) (commanded velocity or acceleration) from an operator input device (45) and transforms them into output signals (47) in such a fashion that the resulting motion is swing free (i.e., end-point swinging prevented). The parameters of the IIR filter are updated in real time using measurements from a hoist cable length encoder (25). The PI feedback controller compensates for modeling errors and external disturbances, such as wind or perturbations caused by collision with objects. The PI feedback controller operates on cable swing angle measurements provided by a cable angle sensor (27). The present invention adjusts acceleration and deceleration to eliminate oscillations. An especially important feature of the present invention is that it compensates for variable-length cable motions from multiple cables attached to a suspended payload.
Ohta, Yoichi; Ishii, Yasumitsu; Ikudome, Sachi; Nakamoto, Hiroki
2014-02-01
The effects of weighted bat warm-up on adjustment of upper limb muscle activity were investigated during baseball bat swinging under dynamic conditions that require a spatial and temporal adjustment of the swinging to hit a moving target. Seven male college baseball players participated in this study. Using a batting simulator, the task was to swing the standard bat coincident with the arrival timing and position of a moving target after three warm-up swings using a standard or weighted bat. There was no significant effect of weighted bat warm-up on muscle activity before impact associated with temporal or spatial movement corrections. However, lower inhibition of the extensor carpi ulnaris muscle activity was observed in a velocity-changed condition in the weighted bat warm-up, as compared to a standard bat warm-up. It is suggested that weighted bat warm-up decreases the adjustment ability associated with inhibition of muscle activation under movement correction conditions.
Activity of upper limb muscles during human walking.
Kuhtz-Buschbeck, Johann P; Jing, Bo
2012-04-01
The EMG activity of upper limb muscles during human gait has rarely been studied previously. It was examined in 20 normal volunteers in four conditions: walking on a treadmill (1) with unrestrained natural arm swing (Normal), (2) while volitionally holding the arms still (Held), (3) with the arms immobilized (Bound), and (4) with the arms swinging in phase with the ipsilateral legs, i.e. opposite-to-normal phasing (Anti-Normal). Normal arm swing involved weak rhythmical lengthening and shortening contractions of arm and shoulder muscles. Phasic muscle activity was needed to keep the unrestricted arms still during walking (Held), indicating a passive component of arm swing. An active component, possibly programmed centrally, existed as well, because some EMG signals persisted when the arms were immobilized during walking (Bound). Anti-Normal gait involved stronger EMG activity than Normal walking and was uneconomical. The present results indicate that normal arm swing has both passive and active components. Copyright © 2011 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Bradshaw, Elizabeth J.; Keogh, Justin W. L.; Hume, Patria A.; Maulder, Peter S.; Nortje, Jacques; Marnewick, Michel
2009-01-01
The purpose of this study was to examine the role of neuromotor noise on golf swing performance in high- and low-handicap players. Selected two-dimensional kinematic measures of 20 male golfers (n = 10 per high- or low-handicap group) performing 10 golf swings with a 5-iron club was obtained through video analysis. Neuromotor noise was calculated…
On swinging spring chaotic oscillations
NASA Astrophysics Data System (ADS)
Aldoshin, Gennady T.; Yakovlev, Sergey P.
2018-05-01
In this work, chaotic modes of Swinging spring oscillations, their appearing conditions and probable scenario of evolution are studied. Swinging spring two-dimensional potential has (under certain conditions) local maximum. It can lead to stochastic attractor appearing. The system instability reason is inner (auto-parametric) resonance with frequencies ratio 2:1, which allows us to conclude that attractor could evolve according to the period doubling scenario, which was predicted by Feigenbaum in 1978.
NASA Astrophysics Data System (ADS)
Korytov, M. S.; Shcherbakov, V. S.; Titenko, V. V.
2018-01-01
Limitation of the swing of the bridge crane cargo rope is a matter of urgency, as it can significantly improve the efficiency and safety of the work performed. In order to completely dampen the pendulum swing after the break-up of a bridge or a bridge-crane freight cart to maximum speed, it is necessary, in the normal repulsion control of the electric motor, to split the process of dispersion into a minimum of three gaps. For a dynamic system of swinging of a bridge crane on a flexible cable hanger in a separate vertical plane, an analytical solution was obtained to determine the temporal dependence of the cargo rope angle relative to the gravitational vertical when the cargo suspension point moves with constant acceleration. The resulting analytical dependence of the cargo rope angle and its first derivative can break the process of dispersing the cargo suspension point into three stages of dispersal and braking with various accelerations and enter maximum speed of movement of the cargo suspension point. In doing so, the condition of eliminating the swings of the cargo rope relative to the gravitational vertical is fulfilled. Provides examples of the maximum speed output constraints-to-time when removing the rope swing.
Lauder, S; Cosgrove, V E; Gliddon, E; Grimm, D; Dodd, S; Berk, L; Castle, D; Suppes, T S; Berk, M
2017-05-01
MoodSwings 2.0 is a self-guided online intervention for bipolar disorder. The intervention incorporates technological improvements on an earlier validated version of the intervention (MoodSwings 1.0). The previous MoodSwings trial provides this study with a unique opportunity to progress previous work, whilst being able to take into consideration lesson learnt, and technological enhancements. The structure and technology of MoodSwings 2.0 are described and the relevance to other online health interventions is highlighted. An international team from Australia and the US updated and improved the programs content pursuant to changes in DSM-5, added multimedia components and included larger numbers of participants in the group discussion boards. Greater methodological rigour in this trial includes an attention control condition, quarterly telephone assessments, and red flag alerts for significant clinical change. This paper outlines these improvements, including additional security and safety measures. A 3 arm RCT is currently evaluating the enhanced program to assess the efficacy of MS 2.0; the primary outcome is change in depressive and manic symptoms. To our knowledge this is the first randomized controlled online bipolar study with a discussion board attention control and meets the key methodological criteria for online interventions. Copyright © 2017. Published by Elsevier Inc.
Lauder, S.; Cosgrove, V.E.; Gliddon, E.; Grimm, D.; Dodd, S.; Berk, L.; Castle, D.; Suppes, T.S.; Berk, M.
2017-01-01
MoodSwings 2.0 is a self-guided online intervention for bipolar disorder. The intervention incorporates technological improvements on an earlier validated version of the intervention (MoodSwings 1.0). The previous MoodSwings trial provides this study with a unique opportunity to progress previous work, whilst being able to take into consideration lesson learnt, and technological enhancements. The structure and technology of MoodSwings 2.0 are described and the relevance to other online health interventions is highlighted. An international team from Australia and the US updated and improved the programs content pursuant to changes in DSM-5, added multimedia components and included larger numbers of participants in the group discussion boards. Greater methodological rigour in this trial includes an attention control condition, quarterly telephone assessments, and red flag alerts for significant clinical change. This paper outlines these improvements, including additional security and safety measures. A 3 arm RCT is currently evaluating the enhanced program to assess the efficacy of MS 2.0; the primary outcome is change in depressive and manic symptoms. To our knowledge this is the first randomised controlled online bipolar study with a discussion board attention control and meets the key methodological criteria for online interventions PMID:28257919
Synchronized metronome training induces changes in the kinematic properties of the golf swing.
Sommer, Marius; Häger, Charlotte; Rönnqvist, Louise
2014-03-01
The purpose of this study was to evaluate possible effects of synchronized metronome training (SMT) on movement dynamics during golf-swing performance, as captured by kinematic analysis. A one-group, between-test design was applied on 13 male golfers (27.5 +/- 4.6 years old, 12.7 +/- 4.9 handicap) who completed 12 sessions of SMT over a four-week period. Pre- and post-assessments of golf swings with three different clubs (4-iron, 7-iron, and pitching wedge) were performed using a three-dimensional motion capture system. Club velocity at three different swing phases (backswing, downswing, and follow-through) was measured and cross-correlation analysis of time-series signals were made on joint couplings (wrist-elbow-shoulder) of both arms, and between joints and the club, during the full golf swing. There were significantly higher cross-correlations between joint-couplings and concomitant changes of the associated phase-shift differences, as well as reduced phase-shift variability at post-test. No significant effect of SMT was found for the club velocities. We suggest that domain-general influences of SMT on the underlying brain-based motor control strategies lead to a more coordinated movement pattern of the golf-swing performance, which may explain previous observations of significantly improved golf-shot accuracy and decreased variability after SMT.
Compensatory mechanisms of balance to the scaling of arm-swing frequency.
Ko, Ji Hyun; Wang, Zheng; Challis, John H; Newell, Karl M
2015-11-05
The present study investigated the contribution of the Hof (2007) mechanism 1 (M1-moving the center of pressure (COP) with respect to the vertical projection of the center of mass (COMTotal)); and mechanism 2 (M2-rotating the trunk and upper limbs around the COMTotal) to postural control and the stability of COP-COMTotal cophase as a function of lateral arm-swing frequency. Young adults were instructed to stand still on a force platform while alternating their arm swinging from above the head to the side of their thigh to create perturbations to postural control. Scaling the frequency of arm-swing (random step changes of 0.2 Hz within a bandwidth of 0.2 to 1.6 Hz) increased the SD of COP but decreased the SD of COMTotal. Increments in arm-swing frequency induced a progressive increase in M1 and decrease in M2 in terms of their relative contribution to postural stability. The cophase between COP and COMTotal became more tightly in-phase over increments of arm-swing frequency. These findings show an adaptive compensatory role of M1 and M2 within the stability of COP-COMTotal coupling in the regulation of human balance control. Copyright © 2015 Elsevier Ltd. All rights reserved.
A neuromechanical strategy for mediolateral foot placement in walking humans.
Rankin, Bradford L; Buffo, Stephanie K; Dean, Jesse C
2014-07-15
Stability is an important concern during human walking and can limit mobility in clinical populations. Mediolateral stability can be efficiently controlled through appropriate foot placement, although the underlying neuromechanical strategy is unclear. We hypothesized that humans control mediolateral foot placement through swing leg muscle activity, basing this control on the mechanical state of the contralateral stance leg. Participants walked under Unperturbed and Perturbed conditions, in which foot placement was intermittently perturbed by moving the right leg medially or laterally during the swing phase (by ∼50-100 mm). We quantified mediolateral foot placement, electromyographic activity of frontal-plane hip muscles, and stance leg mechanical state. During Unperturbed walking, greater swing-phase gluteus medius (GM) activity was associated with more lateral foot placement. Increases in GM activity were most strongly predicted by increased mediolateral displacement between the center of mass (CoM) and the contralateral stance foot. The Perturbed walking results indicated a causal relationship between stance leg mechanics and swing-phase GM activity. Perturbations that reduced the mediolateral CoM displacement from the stance foot caused reductions in swing-phase GM activity and more medial foot placement. Conversely, increases in mediolateral CoM displacement caused increased swing-phase GM activity and more lateral foot placement. Under both Unperturbed and Perturbed conditions, humans controlled their mediolateral foot placement by modulating swing-phase muscle activity in response to the mechanical state of the contralateral leg. This strategy may be disrupted in clinical populations with a reduced ability to modulate muscle activity or sense their body's mechanical state.
Ficklin, Travis; Lund, Robin; Schipper, Megan
2014-01-01
The purpose of this study was to compare traditional and swing blocking techniques on center of mass (COM) projectile motion and effective blocking area in nine healthy Division I female volleyball players. Two high-definition (1080 p) video cameras (60 Hz) were used to collect two-dimensional variables from two separate views. One was placed perpendicular to the plane of the net and the other was directed along the top of the net, and were used to estimate COM locations and blocking area in a plane parallel to the net and hand penetration through the plane of the net respectively. Video of both the traditional and swing techniques were digitized and kinematic variables were calculated. Paired samples t-tests indicated that the swing technique resulted in greater (p < 0.05) vertical and horizontal takeoff velocities (vy and vx), jump height (H), duration of the block (tBLOCK), blocking coverage during the block (C) as well as hand penetration above and through the net’s plane (YPEN, ZPEN). The traditional technique had significantly greater approach time (tAPP). The results of this study suggest that the swing technique results in both greater jump height and effective blocking area. However, the shorter tAPP that occurs with swing is associated with longer times in the air during the block which may reduce the ability of the athlete to make adjustments to attacks designed to misdirect the defense. Key Points Swing blocking technique has greater jump height, effective blocking area, hand penetration, horizontal and vertical takeoff velocity, and has a shorter time of approach. Despite these advantages, there may be more potential for mistiming blocks and having erratic deflections of the ball after contact when using the swing technique. Coaches should take more than simple jump height and hand penetration into account when deciding which technique to employ. PMID:24570609
Ficklin, Travis; Lund, Robin; Schipper, Megan
2014-01-01
The purpose of this study was to compare traditional and swing blocking techniques on center of mass (COM) projectile motion and effective blocking area in nine healthy Division I female volleyball players. Two high-definition (1080 p) video cameras (60 Hz) were used to collect two-dimensional variables from two separate views. One was placed perpendicular to the plane of the net and the other was directed along the top of the net, and were used to estimate COM locations and blocking area in a plane parallel to the net and hand penetration through the plane of the net respectively. Video of both the traditional and swing techniques were digitized and kinematic variables were calculated. Paired samples t-tests indicated that the swing technique resulted in greater (p < 0.05) vertical and horizontal takeoff velocities (vy and vx), jump height (H), duration of the block (tBLOCK), blocking coverage during the block (C) as well as hand penetration above and through the net's plane (YPEN, ZPEN). The traditional technique had significantly greater approach time (tAPP). The results of this study suggest that the swing technique results in both greater jump height and effective blocking area. However, the shorter tAPP that occurs with swing is associated with longer times in the air during the block which may reduce the ability of the athlete to make adjustments to attacks designed to misdirect the defense. Key PointsSwing blocking technique has greater jump height, effective blocking area, hand penetration, horizontal and vertical takeoff velocity, and has a shorter time of approach.Despite these advantages, there may be more potential for mistiming blocks and having erratic deflections of the ball after contact when using the swing technique.Coaches should take more than simple jump height and hand penetration into account when deciding which technique to employ.
Mâaref, Khaled; Martinet, Noël; Grumillier, Constance; Ghannouchi, Slaheddine; André, Jean Marie; Paysant, Jean
2010-06-01
To analyze the spatiotemporal parameters in the terminal swing phase of the prosthetic limb in unilateral transfemoral amputees (TFAs) compared with a group of asymptomatic subjects, and to identify a latency period (LP) in the TFA between the full extension of the prosthetic knee and the initial ground contact of the ipsilateral foot. To study the correlation between the LP and the duration of the swing phase. To evaluate the influence of the type of knee, the time since amputation, and the amputation level on the latency period. Three-dimensional gait analysis with an optoelectronic device. Gait analysis laboratory of a re-education and functional rehabilitation service. TFA (n=29) and able-bodied (n=15) subjects. Not applicable. Spatiotemporal and kinematics gait parameters. The swing phase and the LP of the prosthetic limb, associated with a consequently longer single-limb stance phase in the intact limb, were significantly longer than those measured in the intact limbs of these subjects, as well as those measured on both lower limbs of the able-bodied subjects (P<.05). There is a positive correlation (P<.05; r(2)=.58 between the LP and the swing phase on the TFA's prosthetic side. The LP measured in the prosthetic limb of TFA with a swing-phase control prosthetic knee is significantly greater than in those using the microprocessor-controlled prosthetic knee (P<.05). Of negligible duration in able-bodied subjects and in the intact limb of TFA, the LP is significantly greater in the prosthetic limb. It can explain the lengthened swing phase on the prosthetic side of those subjects. The use of a microprocessor-controlled prosthetic knee allows the LP to be reduced. This LP appears to be necessary to insure the stability of the prosthetic knee. We suggest calling this time "confidence time." Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Quality assurance of a gimbaled head swing verification using feature point tracking.
Miura, Hideharu; Ozawa, Shuichi; Enosaki, Tsubasa; Kawakubo, Atsushi; Hosono, Fumika; Yamada, Kiyoshi; Nagata, Yasushi
2017-01-01
To perform dynamic tumor tracking (DTT) for clinical applications safely and accurately, gimbaled head swing verification is important. We propose a quantitative gimbaled head swing verification method for daily quality assurance (QA), which uses feature point tracking and a web camera. The web camera was placed on a couch at the same position for every gimbaled head swing verification, and could move based on a determined input function (sinusoidal patterns; amplitude: ± 20 mm; cycle: 3 s) in the pan and tilt directions at isocenter plane. Two continuous images were then analyzed for each feature point using the pyramidal Lucas-Kanade (LK) method, which is an optical flow estimation algorithm. We used a tapped hole as a feature point of the gimbaled head. The period and amplitude were analyzed to acquire a quantitative gimbaled head swing value for daily QA. The mean ± SD of the period were 3.00 ± 0.03 (range: 3.00-3.07) s and 3.00 ± 0.02 (range: 3.00-3.07) s in the pan and tilt directions, respectively. The mean ± SD of the relative displacement were 19.7 ± 0.08 (range: 19.6-19.8) mm and 18.9 ± 0.2 (range: 18.4-19.5) mm in the pan and tilt directions, respectively. The gimbaled head swing was reliable for DTT. We propose a quantitative gimbaled head swing verification method for daily QA using the feature point tracking method and a web camera. Our method can quantitatively assess the gimbaled head swing for daily QA from baseline values, measured at the time of acceptance and commissioning. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
A comparative study of two different uncinectomy techniques: swing-door and classical.
Singhania, Ankit A; Bansal, Chetan; Chauhan, Nirali; Soni, Saurav
2012-01-01
The aim of this study was to determine which technique of uncinectomy, classical or swing door technique. Four hundred eighty Cases of sinusitis were selected and operated for Functional Endoscopic Sinus Surgery (FESS). Out of these, in 240 uncinectomies classical uncinectomy was done whereas in another 240 uncinectomies swing door technique was used. Initially patients were medically managed treated according to their symptoms and prior management. Patients who had received previous adequate medical management were evaluated with CT scan of the sinuses. If disease still persists than they were operated for FESS. The authors' experience indicates that Functional endoscopic sinus surgery can be performed under local or general anesthesia, as permitted or tolerated. In this review classical technique was used in 240 uncinectomies. Out of this, ethmoidal complex injury was noted in 4 cases, missed maxillary ostium syndrome (incomplete removal) was reported in 12 patients and orbital fat exposure was encountered in 5 patients. As compared to 240 uncinectomies done with swing door technique, incomplete removal was evident in 2 cases and lacrimal duct injury was reported in 3 cases. 'Evidence that underscores how this 'swing door technique' successfully combines 'the conservation goals of the anterior-to-posterior approach and anatomic virtues of the posterior-to-anterior approach to ethmoidectomy of the total 480 uncinectomies operated. Out of which 240 uncinectomies have been performed using the 'swing-door' technique. The 240 uncinectomies performed using classical technique were used as controls. The incidence of orbital penetration, incomplete removal, ethmoidal complex injury and ostium non-identification was significantly less with the new technique. Three lacrimal injuries occurred with the 'swing-door' technique compared to no injuries with classical technique. The authors recommend swing door technique as it is easy to learn, allows complete removal of the uncinate flush with the lateral nasal wall and allows easy identification of the natural ostium of the maxillary sinus without injuring the ethmoidal complex.
Dreher, Thomas; Wolf, Sebastian I; Maier, Michael; Hagmann, Sébastien; Vegvari, Dóra; Gantz, Simone; Heitzmann, Daniel; Wenz, Wolfram; Braatz, Frank
2012-10-03
The evidence for distal rectus femoris transfer as a part of multilevel surgery for the correction of stiff-knee gait in children with spastic diplegic cerebral palsy is limited because of inconsistent outcomes reported in various studies and the lack of long-term evaluations. This study investigated the long-term results (mean, nine years) for fifty-three ambulatory patients with spastic diplegic cerebral palsy and stiff-knee gait treated with standardized distal rectus femoris transfer as a part of multilevel surgery. Standardized three-dimensional gait analysis and clinical examination were carried out before surgery and at one year and nine years after surgery. Patients with decreased peak knee flexion in swing phase who had distal rectus femoris transfer to correct the decreased peak knee flexion in swing phase (C-DRFT) were evaluated separately from those with normal or increased peak knee flexion in swing phase who had distal rectus femoris transfer done as a prophylactic procedure (P-DRFT). A significantly increased peak knee flexion in swing phase was found in the C-DRFT group one year after surgery, while a significant loss (15°) in peak knee flexion in swing phase was noted in the P-DRFT group. A slight but not significant increase in peak knee flexion in swing phase in both groups was noted at the time of the long-term follow-up. A significant improvement in timing of peak knee flexion in swing phase was only found for the C-DRFT group, and was maintained after nine years. Knee motion and knee flexion velocity were significantly increased in both groups and were maintained at long-term follow-up in the C-DRFT group, while the P-DRFT showed a deterioration of knee motion. Distal rectus femoris transfer is an effective procedure to treat stiff-knee gait featuring decreased peak knee flexion in swing phase and leads to a long-lasting increase of peak knee flexion in swing phase nine years after surgery. Patients with more involvement showed a greater potential to benefit from distal rectus femoris transfer. However, 18% of the patients showed a permanently poor response and 15% developed recurrence. In patients with severe knee flexion who underwent a prophylactic distal rectus femoris transfer, a significant loss in peak knee flexion in swing phase was noted and thus a prophylactic distal rectus femoris transfer may not be indicated in these patients. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Flexible thin-film transistors on plastic substrate at room temperature.
Han, Dedong; Wang, Wei; Cai, Jian; Wang, Liangliang; Ren, Yicheng; Wang, Yi; Zhang, Shengdong
2013-07-01
We have fabricated flexible thin-film transistors (TFTs) on plastic substrates using Aluminum-doped ZnO (AZO) as an active channel layer at room temperature. The AZO-TFTs showed n-channel device characteristics and operated in enhancement mode. The device shows a threshold voltage of 1.3 V, an on/off ratio of 2.7 x 10(7), a field effect mobility of 21.3 cm2/V x s, a subthreshold swing of 0.23 V/decade, and the off current of less than 10(-12) A at room temperature. Recently, the flexible displays have become a very hot topic. Flexible thin film transistors are key devices for realizing flexible displays. We have investigated AZO-TFT on flexible plastic substrate, and high performance flexible TFTs have been obtained.
NASA Astrophysics Data System (ADS)
Bebiche, S.; Bouhadda, I.; Mohammed-Brahim, T.; Coulon, N.; Bergamini, J. F.; Poriel, C.; Jacques, E.
2017-04-01
In this work we report the fabrication of N channel transistors based on IF(CN2)2 meta molecule. The effect of IF(CN2)2 meta evaporation parameters on corresponding TFTs performances, is evaluated and highlighted here. Since the effect of deposition conditions for this molecule type has not been reported yet, here we report an improvement about 20 times of field effect mobility when deposited at substrate temperature of 80 °C and deposition rate of 0.7 Å/s, and then annealed at low temperature. Reached mobility of 2.2 × 10-3 cm2/V·s, is comparable to reported μFE of single crystal indenofluorene TFTs. The optimum mobility in these evaporation conditions was explained by the best compromise between the grain size and packing density of films. Fabricated IF(CN2)2 meta based devices are combined to 6,13-Bis(triisopropylsilylethynyl)pentacene devices and then integrated into a CMOS inverter logic circuit. The inverter's VTC shows large output voltage swing. Electrical stability of the performed inverter was also evaluated and the inverter shows a correct electrical stability, after 3 h of non-stop operation and the peak to peak magnitude corresponding to VOUT decreases only by 2.6%.
Importance of water quality in container plant production
John M. Ruter
2013-01-01
High substrate pH is a major problem for producers of container-grown plants and seedlings. The primary cause of high substrate pH is irrigation water with high alkalinity. Alkalinity is defined as the capacity of water to neutralize acids. Some alkalinity in irrigation water is beneficial as it serves as a buffer to large swings in pH levels, but high alkalinity in...
A double pendulum model of tennis strokes
NASA Astrophysics Data System (ADS)
Cross, Rod
2011-05-01
The physics of swinging a tennis racquet is examined by modeling the forearm and the racquet as a double pendulum. We consider differences between a forehand and a serve, and show how they differ from the swing of a bat and a golf club. It is also shown that the swing speed of a racquet, like that of a bat or a club, depends primarily on its moment of inertia rather than on its mass.
The relationship between biomechanical variables and driving performance during the golf swing.
Chu, Yungchien; Sell, Timothy C; Lephart, Scott M
2010-09-01
Swing kinematic and ground reaction force data from 308 golfers were analysed to identify the variables important to driving ball velocity. Regression models were applied at four selected events in the swing. The models accounted for 44-74% of variance in ball velocity. Based on the regression analyses, upper torso-pelvis separation (the X-Factor), delayed release (i.e. the initiation of movement) of the arms and wrists, trunk forward and lateral tilting, and weight-shifting during the swing were significantly related to ball velocity. Our results also verify several general coaching ideas that were considered important to increased ball velocity. The results of this study may serve as both skill and strength training guidelines for golfers.
Torsion effect of swing frame on the measurement of horizontal two-plane balancing machine
NASA Astrophysics Data System (ADS)
Wang, Qiuxiao; Wang, Dequan; He, Bin; Jiang, Pan; Wu, Zhaofu; Fu, Xiaoyan
2017-03-01
In this paper, the vibration model of swing frame of two-plane balancing machine is established to calculate the vibration center position of swing frame first. The torsional stiffness formula of spring plate twisting around the vibration center is then deduced by using superposition principle. Finally, the dynamic balancing experiments prove the irrationality of A-B-C algorithm which ignores the torsion effect, and show that the torsional stiffness deduced by experiments is consistent with the torsional stiffness calculated by theory. The experimental datas show the influence of the torsion effect of swing frame on the separation ratio of sided balancing machines, which reveals the sources of measurement error and assesses the application scope of A-B-C algorithm.
NASA Astrophysics Data System (ADS)
Merlaud, Alexis; Tack, Frederik; Constantin, Daniel; Fayt, Caroline; Maes, Jeroen; Mingireanu, Florin; Mocanu, Ionut; Georgescu, Lucian; Van Roozendael, Michel
2015-04-01
The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) is an instrument dedicated to atmospheric trace gas retrieval from an Unmanned Aerial Vehicle (UAV). The payload is based on a compact visible spectrometer and a scanning mirror to collect scattered sunlight. Its weight, size, and power consumption are respectively 920 g, 27x12x12 cm3, and 6 W. The custom-built 2.5 m flying wing UAV is electrically powered, has a typical airspeed of 100 km/h, and can operate at a maximum altitude of 3 km. Both the payload and the UAV were developed in the framework of a collaboration between the Belgian Institute for Space Aeronomy (BIRA-IASB) and the Dunarea de Jos University of Galati, Romania. We present here SWING-UAV test flights dedicated to NO2 measurements and performed in Romania on 10 and 11 September 2014, during the Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaign. The UAV performed 5 flights in the vicinity of the large thermal power station of Turceni (44.67° N, 23.4° E). The UAV was operated in visual range during the campaign, up to 900 m AGL , downwind of the plant and crossing its exhaust plume. The spectra recorded on flight are analyzed with the Differential Optical Absorption Spectroscopy (DOAS) method. The retrieved NO2 Differential Slant Column Densities (DSCDs) are up to 1.5e17 molec/cm2 and reveal the horizontal gradients around the plant. The DSCDs are converted to vertical columns and compared with coincident car-based DOAS measurements. We also present the near-future perspective of the SWING-UAV observation system, which includes flights in 2015 above the Black Sea to quantify ship emissions, the addition of SO2 as a target species, and autopilot flights at higher altitudes to cover a typical satellite pixel extent (10x10 km2).
Temperature-dependent performance of all-NbN DC-SQUID magnetometers
NASA Astrophysics Data System (ADS)
Liu, Quansheng; Wang, Huiwu; Zhang, Qiyu; Wang, Hai; Peng, Wei; Wang, Zhen
2017-05-01
Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current-voltage and voltage-flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.
NASA Astrophysics Data System (ADS)
Zheng, Jie; Li, Ling; Chen, Weidong
2015-12-01
The bottom anti-reflective coating (BARC) material can enhance the resolution of the nanopatterns structures in laser interference lithography process. In this study, WIDE-B ARC material was investigated to confirm the reduction of the vertical standing wave which leads to defect of nanopatterns. And the critical dimension (CD) of 100 nm L/S patterns with and without the application of BARC material was fabricated by laser interference lithography technology. The compared results showed that BARC can effectively reduce CD swing and obtain more uniform nanopatterns. Meanwhile, we also verified the influence of cured temperature and film thickness of BARC on the uniformity of nanopatterns.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Joung-min, E-mail: cho.j.ad@m.titech.ac.jp; Akiyama, Yuto; Kakinuma, Tomoyuki
2013-10-15
We have investigated trap density of states (trap DOS) in n-channel organic field-effect transistors based on N,N ’-bis(cyclohexyl)naphthalene diimide (Cy-NDI) and dimethyldicyanoquinonediimine (DMDCNQI). A new method is proposed to extract trap DOS from the Arrhenius plot of the temperature-dependent transconductance. Double exponential trap DOS are observed, in which Cy-NDI has considerable deep states, by contrast, DMDCNQI has substantial tail states. In addition, numerical simulation of the transistor characteristics has been conducted by assuming an exponential trap distribution and the interface approximation. Temperature dependence of transfer characteristics are well reproduced only using several parameters, and the trap DOS obtained from the simulatedmore » characteristics are in good agreement with the assumed trap DOS, indicating that our analysis is self-consistent. Although the experimentally obtained Meyer-Neldel temperature is related to the trap distribution width, the simulation satisfies the Meyer-Neldel rule only very phenomenologically. The simulation also reveals that the subthreshold swing is not always a good indicator of the total trap amount, because it also largely depends on the trap distribution width. Finally, band transport is explored from the simulation having a small number of traps. A crossing point of the transfer curves and negative activation energy above a certain gate voltage are observed in the simulated characteristics, where the critical V{sub G} above which band transport is realized is determined by the sum of the trapped and free charge states below the conduction band edge.« less
Process for CO.sub.2 capture using zeolites from high pressure and moderate temperature gas streams
Siriwardane, Ranjani V [Morgantown, WV; Stevens, Robert W [Morgantown, WV
2012-03-06
A method for separating CO.sub.2 from a gas stream comprised of CO.sub.2 and other gaseous constituents using a zeolite sorbent in a swing-adsorption process, producing a high temperature CO.sub.2 stream at a higher CO.sub.2 pressure than the input gas stream. The method utilizes CO.sub.2 desorption in a CO.sub.2 atmosphere and effectively integrates heat transfers for optimizes overall efficiency. H.sub.2O adsorption does not preclude effective operation of the sorbent. The cycle may be incorporated in an IGCC for efficient pre-combustion CO.sub.2 capture. A particular application operates on shifted syngas at a temperature exceeding 200.degree. C. and produces a dry CO.sub.2 stream at low temperature and high CO.sub.2 pressure, greatly reducing any compression energy requirements which may be subsequently required.
Muscle strength and golf performance: a critical review.
Torres-Ronda, Lorena; Sánchez-Medina, Luis; González-Badillo, Juan J
2011-01-01
Golf has become an increasingly popular sport and a growing body of research trying to identify its main physical requirements is being published. The aim of this review was twofold: first, to examine the existing scientific literature regarding strength training and golf in healthy, non-injured, subjects; and second, to reach conclusions that could provide information on how to design more effective strength training programs to improve golf performance as well as directions for future research. Studies which analyzed the relationship between muscle strength, swing performance variables (club head speed, driving distance, ball speed) and skill (handicap, score) were reviewed. Changes in swing performance following different strength training programs were also investigated. Finally, a critical analysis about the methodologies used was carried out. The results of the reviewed studies seem to indicate that: 1) a positive relationship exists between handicap and swing performance (even though few studies have investigated this issue); 2) there is a positive correlation between skill (handicap and/or score) and muscle strength; and 3) there is a relationship between driving distance, swing speed, ball speed and muscle strength. Results suggest that training leg-hip and trunk power as well as grip strength is especially relevant for golf performance improvement. Studies that analyzed variations in swing performance following resistance-only training programs are scarce, thus it is difficult to prove whether the observed improvements are attributable to changes in strength levels. Many of the studies reviewed presented some methodological errors in their design and not all strength assessment protocols seemed appropriate. Further studies should determine muscle strength needs in relation to final swing performance, using well designed experiments and strict isoinertial assessment protocols which adequately relate to specific golf motion, age and skill level. More studies with elite participants, either professional or amateur, would be especially desirable. Key pointsPOSITIVE CORRELATIONS EXIST BETWEEN: 1) handicap and swing performance variables; 2) muscle strength and skill (handicap and/or golf score); and 3) driving dis-tance, swing speed, ball speed and muscle strength.Leg-hip, trunk power and grip strength seem espe-cially relevant for golf performance improvement.Further research should determine muscle strength needs in relation to final swing performance, using well designed experiments and strict assessment pro-tocols which adequately relate to specific golf mo-tion, age and skill level.
Muscle Strength And Golf Performance: A Critical Review
Torres-Ronda, Lorena; Sánchez-Medina, Luis; González-Badillo, Juan J.
2011-01-01
Golf has become an increasingly popular sport and a growing body of research trying to identify its main physical requirements is being published. The aim of this review was twofold: first, to examine the existing scientific literature regarding strength training and golf in healthy, non-injured, subjects; and second, to reach conclusions that could provide information on how to design more effective strength training programs to improve golf performance as well as directions for future research. Studies which analyzed the relationship between muscle strength, swing performance variables (club head speed, driving distance, ball speed) and skill (handicap, score) were reviewed. Changes in swing performance following different strength training programs were also investigated. Finally, a critical analysis about the methodologies used was carried out. The results of the reviewed studies seem to indicate that: 1) a positive relationship exists between handicap and swing performance (even though few studies have investigated this issue); 2) there is a positive correlation between skill (handicap and/or score) and muscle strength; and 3) there is a relationship between driving distance, swing speed, ball speed and muscle strength. Results suggest that training leg-hip and trunk power as well as grip strength is especially relevant for golf performance improvement. Studies that analyzed variations in swing performance following resistance-only training programs are scarce, thus it is difficult to prove whether the observed improvements are attributable to changes in strength levels. Many of the studies reviewed presented some methodological errors in their design and not all strength assessment protocols seemed appropriate. Further studies should determine muscle strength needs in relation to final swing performance, using well designed experiments and strict isoinertial assessment protocols which adequately relate to specific golf motion, age and skill level. More studies with elite participants, either professional or amateur, would be especially desirable. Key points Positive correlations exist between: 1) handicap and swing performance variables; 2) muscle strength and skill (handicap and/or golf score); and 3) driving dis-tance, swing speed, ball speed and muscle strength. Leg-hip, trunk power and grip strength seem espe-cially relevant for golf performance improvement. Further research should determine muscle strength needs in relation to final swing performance, using well designed experiments and strict assessment pro-tocols which adequately relate to specific golf mo-tion, age and skill level. PMID:24149290
The Influence of Footwear on the Modular Organization of Running.
Santuz, Alessandro; Ekizos, Antonis; Janshen, Lars; Baltzopoulos, Vasilios; Arampatzis, Adamantios
2017-01-01
For most of our history, we predominantly ran barefoot or in minimalist shoes. The advent of modern footwear, however, might have introduced alterations in the motor control of running. The present study investigated shod and barefoot running under the perspective of the modular organization of muscle activation, in order to help addressing the neurophysiological factors underlying human locomotion. On a treadmill, 20 young and healthy inexperienced barefoot runners ran shod and barefoot at preferred speed (2.8 ± 0.4 m/s). Fundamental synergies, containing the time-dependent activation coefficients (motor primitives) and the time-invariant muscle weightings (motor modules), were extracted from 24 ipsilateral electromyographic activities using non-negative matrix factorization. In shod running, the average foot strike pattern was a rearfoot strike, while in barefoot running it was a mid-forefoot strike. In both conditions, five fundamental synergies were enough to describe as many gait cycle phases: weight acceptance, propulsion, arm swing, early swing and late swing. We found the motor primitives to be generally shifted earlier in time during the stance-related phases and later in the swing-related ones in barefoot running. The motor primitive describing the propulsion phase was significantly of shorter duration (peculiarity confirmed by the analysis of the spinal motor output). The arm swing primitive, instead, was significantly wider in the barefoot condition. The motor modules demonstrated analogous organization with some significant differences in the propulsion, arm swing and late swing synergies. Other than to the trivial absence of shoes, the differences might be deputed to the lower ankle gear ratio (and the consequent increased system instability) and to the higher recoil capabilities of the longitudinal foot arch during barefoot compared to shod running.
The Influence of Footwear on the Modular Organization of Running
Santuz, Alessandro; Ekizos, Antonis; Janshen, Lars; Baltzopoulos, Vasilios; Arampatzis, Adamantios
2017-01-01
For most of our history, we predominantly ran barefoot or in minimalist shoes. The advent of modern footwear, however, might have introduced alterations in the motor control of running. The present study investigated shod and barefoot running under the perspective of the modular organization of muscle activation, in order to help addressing the neurophysiological factors underlying human locomotion. On a treadmill, 20 young and healthy inexperienced barefoot runners ran shod and barefoot at preferred speed (2.8 ± 0.4 m/s). Fundamental synergies, containing the time-dependent activation coefficients (motor primitives) and the time-invariant muscle weightings (motor modules), were extracted from 24 ipsilateral electromyographic activities using non-negative matrix factorization. In shod running, the average foot strike pattern was a rearfoot strike, while in barefoot running it was a mid-forefoot strike. In both conditions, five fundamental synergies were enough to describe as many gait cycle phases: weight acceptance, propulsion, arm swing, early swing and late swing. We found the motor primitives to be generally shifted earlier in time during the stance-related phases and later in the swing-related ones in barefoot running. The motor primitive describing the propulsion phase was significantly of shorter duration (peculiarity confirmed by the analysis of the spinal motor output). The arm swing primitive, instead, was significantly wider in the barefoot condition. The motor modules demonstrated analogous organization with some significant differences in the propulsion, arm swing and late swing synergies. Other than to the trivial absence of shoes, the differences might be deputed to the lower ankle gear ratio (and the consequent increased system instability) and to the higher recoil capabilities of the longitudinal foot arch during barefoot compared to shod running. PMID:29213246
Correlation of Titleist Performance Institute (TPI) level 1 movement screens and golf swing faults.
Gulgin, Heather R; Schulte, Brian C; Crawley, Amy A
2014-02-01
Although some research in the past has examined how physical limitations in strength or flexibility affect a golfer's performance, the performance outcome most measured was driving distance. Currently, there are no data that have examined the relationship between selected strength and flexibility variables and golf swing faults. The purpose of this study was to examine the relationship between Titleist Performance Institute (TPI) level 1 movement screen variables and 14 common golf swing faults. Thirty-six male and female golfers (mean age, 25.4 ± 9.9 years; height, 175.9 ± 16.2 cm; mass, 76.2 ± 14.6 kg; handicap, 14.2 ± 10.4) participated. Twelve physical tests of strength, flexibility, and balance were assessed using the TPI level 1 golf fitness screening tool. Golfers then hit 4 golf shots (with a 5-iron) while being videoed, and those were then analyzed for 14 different golf swing faults (using V1Pro software). Three significant associations between a physical limitation and a particular golf swing fault were found: toe touch and early hip extension (p = 0.015), bridge on right side with both early hip extension (p = 0.050), and loss of posture (p = 0.028). In addition, an odds ratio showed that when a golfer could not overhead deep squat or single leg balance on left side, they were 2-3 times more likely to exhibit a early hip extension, loss of posture, or slide during the golf swing, as compared with those who could perform a correct overhead deep squat. Based on our findings, it is important for the golf fitness professional to particularly address a golfer's core strength, balance, and hamstring flexibility to help avoid common golf swing faults, which affect a golfer's ball striking ability and ultimately their performance.
NASA Astrophysics Data System (ADS)
Bhattacharyya, Kaustuve; den Boef, Arie; Noot, Marc; Adam, Omer; Grzela, Grzegorz; Fuchs, Andreas; Jak, Martin; Liao, Sax; Chang, Ken; Couraudon, Vincent; Su, Eason; Tzeng, Wilson; Wang, Cathy; Fouquet, Christophe; Huang, Guo-Tsai; Chen, Kai-Hsiung; Wang, Y. C.; Cheng, Kevin; Ke, Chih-Ming; Terng, L. G.
2017-03-01
The optical coupling between gratings in diffraction-based overlay triggers a swing-curve1,6 like response of the target's signal contrast and overlay sensitivity through measurement wavelengths and polarizations. This means there are distinct measurement recipes (wavelength and polarization combinations) for a given target where signal contrast and overlay sensitivity are located at the optimal parts of the swing-curve that can provide accurate and robust measurements. Some of these optimal recipes can be the ideal choices of settings for production. The user has to stay away from the non-optimal recipe choices (that are located on the undesirable parts of the swing-curve) to avoid possibilities to make overlay measurement error that can be sometimes (depending on the amount of asymmetry and stack) in the order of several "nm". To accurately identify these optimum operating areas of the swing-curve during an experimental setup, one needs to have full-flexibility in wavelength and polarization choices. In this technical publication, a diffraction-based overlay (DBO) measurement tool with many choices of wavelengths and polarizations is utilized on advanced production stacks to study swing-curves. Results show that depending on the stack and the presence of asymmetry, the swing behavior can significantly vary and a solid procedure is needed to identify a recipe during setup that is robust against variations in stack and grating asymmetry. An approach is discussed on how to use this knowledge of swing-curve to identify recipe that is not only accurate at setup, but also robust over the wafer, and wafer-to-wafer. KPIs are reported in run-time to ensure the quality / accuracy of the reading (basically acting as an error bar to overlay measurement).
Closeup view under the track at the center/pivot pier showing ...
Close-up view under the track at the center/pivot pier showing the system of distributing girders which transfer all the load of the swing span, both dead, live load, wind, etc., onto the circular drum, thence to the rim bearing 40 20-inch diameter wheels. Note: The track timber ties supported on the bottom truss chord of the swing span truss. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Contributions of muscles and passive dynamics to swing initiation over a range of walking speeds.
Fox, Melanie D; Delp, Scott L
2010-05-28
Stiff-knee gait is a common walking problem in cerebral palsy characterized by insufficient knee flexion during swing. To identify factors that may limit knee flexion in swing, it is necessary to understand how unimpaired subjects successfully coordinate muscles and passive dynamics (gravity and velocity-related forces) to accelerate the knee into flexion during double support, a critical phase just prior to swing that establishes the conditions for achieving sufficient knee flexion during swing. It is also necessary to understand how contributions to swing initiation change with walking speed, since patients with stiff-knee gait often walk slowly. We analyzed muscle-driven dynamic simulations of eight unimpaired subjects walking at four speeds to quantify the contributions of muscles, gravity, and velocity-related forces (i.e. Coriolis and centrifugal forces) to preswing knee flexion acceleration during double support at each speed. Analysis of the simulations revealed contributions from muscles and passive dynamics varied systematically with walking speed. Preswing knee flexion acceleration was achieved primarily by hip flexor muscles on the preswing leg with assistance from biceps femoris short head. Hip flexors on the preswing leg were primarily responsible for the increase in preswing knee flexion acceleration during double support with faster walking speed. The hip extensors and abductors on the contralateral leg and velocity-related forces opposed preswing knee flexion acceleration during double support. Copyright 2010 Elsevier Ltd. All rights reserved.
Contributions of muscles and passive dynamics to swing initiation over a range of walking speeds
Fox, Melanie D.; Delp, Scott L.
2010-01-01
Stiff-knee gait is a common walking problem in cerebral palsy characterized by insufficient knee flexion during swing. To identify factors that may limit knee flexion in swing, it is necessary to understand how unimpaired subjects successfully coordinate muscles and passive dynamics (gravity and velocity-related forces) to accelerate the knee into flexion during double support, a critical phase just prior to swing that establishes the conditions for achieving sufficient knee flexion during swing. It is also necessary to understand how contributions to swing initiation change with walking speed, since patients with stiff-knee gait often walk slowly. We analyzed muscle-driven dynamic simulations of eight unimpaired subjects walking at four speeds to quantify the contributions of muscles, gravity, and velocity-related forces (i.e. Coriolis and centrifugal forces) to preswing knee flexion acceleration during double support at each speed. Analysis of the simulations revealed contributions from muscles and passive dynamics varied systematically with walking speed. Preswing knee flexion acceleration was achieved primarily by hip flexor muscles on the preswing leg with assistance from biceps femoris short head. Hip flexors on the preswing leg were primarily responsible for the increase in preswing knee flexion acceleration during double support with faster walking speed. The hip extensors and abductors on the contralateral leg and velocity-related forces opposed preswing knee flexion acceleration during double support. PMID:20236644
Brown, Susan J; Nevill, Alan M; Monk, Stuart A; Otto, Steve R; Selbie, W Scott; Wallace, Eric S
2011-11-01
Previous studies on the kinematics of the golf swing have mainly focused on group analysis of male golfers of a wide ability range. In the present study, we investigated gross body kinematics using a novel method of analysis for golf research for a group of low handicap female golfers to provide an understanding of their swing mechanics in relation to performance. Data were collected for the drive swings of 16 golfers using a 12-camera three-dimensional motion capture system and a stereoscopic launch monitor. Analysis of covariance identified three covariates (increased pelvis-thorax differential at the top of the backswing, increased pelvis translation during the backswing, and a decrease in absolute backswing time) as determinants of the variance in clubhead speed (adjusted r (2) = 0.965, P < 0.05). A significant correlation was found between left-hand grip strength and clubhead speed (r = 0.54, P < 0.05) and between handicap and clubhead speed (r = -0.612, P < 0.05). Flexibility measures showed some correlation with clubhead speed; both sitting flexibility tests gave positive correlations (clockwise: r = 0.522, P < 0.05; counterclockwise: r = 0.711, P < 0.01). The results suggest that there is no common driver swing technique for optimal performance in low handicap female golfers, and therefore consideration should be given to individual swing characteristics in future studies.
Effects of constrained arm swing on vertical center of mass displacement during walking.
Yang, Hyung Suk; Atkins, Lee T; Jensen, Daniel B; James, C Roger
2015-10-01
The purpose of this study was to determine the effects of constraining arm swing on the vertical displacement of the body's center of mass (COM) during treadmill walking and examine several common gait variables that may account for or mask differences in the body's COM motion with and without arm swing. Participants included 20 healthy individuals (10 male, 10 female; age: 27.8 ± 6.8 years). The body's COM displacement, first and second peak vertical ground reaction forces (VGRFs), and lowest VGRF during mid-stance, peak summed bilateral VGRF, lower extremity sagittal joint angles, stride length, and foot contact time were measured with and without arm swing during walking at 1.34 m/s. The body's COM displacement was greater with the arms constrained (arm swing: 4.1 ± 1.2 cm, arm constrained: 4.9 ± 1.2 cm, p < 0.001). Ground reaction force data indicated that the COM displacement increased in both double limb and single limb stance. However, kinematic patterns visually appeared similar between conditions. Shortened stride length and foot contact time also were observed, although these do not seem to account for the increased COM displacement. However, a change in arm COM acceleration might have contributed to the difference. These findings indicate that a change in arm swing causes differences in vertical COM displacement, which could increase energy expenditure. Copyright © 2015 Elsevier B.V. All rights reserved.
Dey, Sanjay
2017-01-01
Vibrio cholerae experiences a highly hostile environment at human intestine which triggers the induction of various heat shock genes. The hchA gene product of V. cholerae O395, referred to a hypothetical intracellular protease/amidase VcHsp31, is one such stress-inducible homodimeric protein. Our current study demonstrates that VcHsp31 is endowed with molecular chaperone, amidopeptidase and robust methylglyoxalase activities. Through site directed mutagenesis coupled with biochemical assays on VcHsp31, we have confirmed the role of residues in the vicinity of the active site towards amidopeptidase and methylglyoxalase activities. VcHsp31 suppresses the aggregation of insulin in vitro in a dose dependent manner. Through crystal structures of VcHsp31 and its mutants, grown at various temperatures, we demonstrate that VcHsp31 acquires two (Type-I and Type-II) dimeric forms. Type-I dimer is similar to EcHsp31 where two VcHsp31 monomers associate in eclipsed manner through several intersubunit hydrogen bonds involving their P-domains. Type-II dimer is a novel dimeric organization, where some of the intersubunit hydrogen bonds are abrogated and each monomer swings out in the opposite directions centering at their P-domains, like twisting of wet cloth. Normal mode analysis (NMA) of Type-I dimer shows similar movement of the individual monomers. Upon swinging, a dimeric surface of ~400Å2, mostly hydrophobic in nature, is uncovered which might bind partially unfolded protein substrates. We propose that, in solution, VcHsp31 remains as an equilibrium mixture of both the dimers. With increase in temperature, transformation to Type-II form having more exposed hydrophobic surface, occurs progressively accounting for the temperature dependent increase of chaperone activity of VcHsp31. PMID:28235098
Ezbiri, Miriam; Takacs, Michael; Stolz, Boris; Lungthok, Jeffrey; Steinfeld, Aldo
2017-01-01
Perovskites are attractive redox materials for thermo/electrochemical fuel synthesis. To design perovskites with balanced redox energetics for thermochemically splitting CO2, the activity of lattice oxygen vacancies and stability against crystal phase changes and detrimental carbonate formation are predicted for a representative range of perovskites by electronic structure computations. Systematic trends in these materials properties when doping with selected metal cations are described in the free energy range defined for isothermal and temperature-swing redox cycles. To confirm that the predicted materials properties root in the bulk chemical composition, selected perovskites are synthesized and characterized by X-ray diffraction, transmission electron microscopy, and thermogravimetric analysis. On one hand, due to the oxidation equilibrium, none of the investigated compositions outperforms non-stoichiometric ceria – the benchmark redox material for CO2 splitting with temperature-swings in the range of 800–1500 °C. On the other hand, certain promising perovskites remain redox-active at relatively low oxide reduction temperatures at which ceria is redox-inactive. This trade-off in the redox energetics is established for YFeO3, YCo0.5Fe0.5O3 and LaFe0.5Ni0.5O3, identified as stable against phase changes and capable to convert CO2 to CO at 600 °C and 10 mbar CO in CO2, and to being decomposed at 1400 °C and 0.1 mbar O2 with an enthalpy change of 440–630 kJ mol–1 O2. PMID:29456856
Development and Feasibility Assessment of a Rotational Orthosis for Walking with Arm Swing.
Fang, Juan; Xie, Qing; Yang, Guo-Yuan; Xie, Le
2017-01-01
Interlimb neural coupling might underlie human bipedal locomotion, which is reflected in the fact that people swing their arms synchronously with leg movement in normal gait. Therefore, arm swing should be included in gait training to provide coordinated interlimb performance. The present study aimed to develop a Rotational Orthosis for Walking with Arm Swing (ROWAS), and evaluate its feasibility from the perspectives of implementation, acceptability and responsiveness. We developed the mechanical structures of the ROWAS system in SolidWorks, and implemented the concept in a prototype. Normal gait data were used as the reference performance of the shoulder, hip, knee and ankle joints of the prototype. The ROWAS prototype was tested for function assessment and further evaluated using five able-bodied subjects for user feedback. The ROWAS prototype produced coordinated performance in the upper and lower limbs, with joint profiles similar to those occurring in normal gait. The subjects reported a stronger feeling of walking with arm swing than without. The ROWAS system was deemed feasible according to the formal assessment criteria.
NASA Astrophysics Data System (ADS)
Zhang, Menghua; Ma, Xin; Rong, Xuewen; Tian, Xincheng; Li, Yibin
2017-02-01
This paper exploits an error tracking control method for overhead crane systems for which the error trajectories for the trolley and the payload swing can be pre-specified. The proposed method does not require that the initial payload swing angle remains zero, whereas this requirement is usually assumed in conventional methods. The significant feature of the proposed method is its superior control performance as well as its strong robustness over different or uncertain rope lengths, payload masses, desired positions, initial payload swing angles, and external disturbances. Owing to the same attenuation behavior, the desired error trajectory for the trolley for each traveling distance is not needed to be reset, which is easy to implement in practical applications. By converting the error tracking overhead crane dynamics to the objective system, we obtain the error tracking control law for arbitrary initial payload swing angles. Lyapunov techniques and LaSalle's invariance theorem are utilized to prove the convergence and stability of the closed-loop system. Simulation and experimental results are illustrated to validate the superior performance of the proposed error tracking control method.
Development and Feasibility Assessment of a Rotational Orthosis for Walking with Arm Swing
Fang, Juan; Xie, Qing; Yang, Guo-Yuan; Xie, Le
2017-01-01
Interlimb neural coupling might underlie human bipedal locomotion, which is reflected in the fact that people swing their arms synchronously with leg movement in normal gait. Therefore, arm swing should be included in gait training to provide coordinated interlimb performance. The present study aimed to develop a Rotational Orthosis for Walking with Arm Swing (ROWAS), and evaluate its feasibility from the perspectives of implementation, acceptability and responsiveness. We developed the mechanical structures of the ROWAS system in SolidWorks, and implemented the concept in a prototype. Normal gait data were used as the reference performance of the shoulder, hip, knee and ankle joints of the prototype. The ROWAS prototype was tested for function assessment and further evaluated using five able-bodied subjects for user feedback. The ROWAS prototype produced coordinated performance in the upper and lower limbs, with joint profiles similar to those occurring in normal gait. The subjects reported a stronger feeling of walking with arm swing than without. The ROWAS system was deemed feasible according to the formal assessment criteria. PMID:28203142
Bradshaw, Elizabeth J; Keogh, Justin W L; Hume, Patria A; Maulder, Peter S; Nortje, Jacques; Marnewick, Michel
2009-06-01
The purpose of this study was to examine the role of neuromotor noise on golf swing performance in high- and low-handicap players. Selected two-dimensional kinematic measures of 20 male golfers (n=10 per high- or low-handicap group) performing 10 golf swings with a 5-iron club was obtained through video analysis. Neuromotor noise was calculated by deducting the standard error of the measurement from the coefficient of variation obtained from intra-individual analysis. Statistical methods included linear regression analysis and one-way analysis of variance using SPSS. Absolute invariance in the key technical positions (e.g., at the top of the backswing) of the golf swing appears to be a more favorable technique for skilled performance.
A load-based mechanism for inter-leg coordination in insects
2017-01-01
Animals rely on an adaptive coordination of legs during walking. However, which specific mechanisms underlie coordination during natural locomotion remains largely unknown. One hypothesis is that legs can be coordinated mechanically based on a transfer of body load from one leg to another. To test this hypothesis, we simultaneously recorded leg kinematics, ground reaction forces and muscle activity in freely walking stick insects (Carausius morosus). Based on torque calculations, we show that load sensors (campaniform sensilla) at the proximal leg joints are well suited to encode the unloading of the leg in individual steps. The unloading coincides with a switch from stance to swing muscle activity, consistent with a load reflex promoting the stance-to-swing transition. Moreover, a mechanical simulation reveals that the unloading can be ascribed to the loading of a specific neighbouring leg, making it exploitable for inter-leg coordination. We propose that mechanically mediated load-based coordination is used across insects analogously to mammals. PMID:29187626
13. View of swing span showing bridge operator's control cabin, ...
13. View of swing span showing bridge operator's control cabin, looking northeast - India Point Railroad Bridge, Spanning Seekonk River between Providence & East Providence, Providence, Providence County, RI
Rosetta Navigation at its Mars Swing-By
NASA Technical Reports Server (NTRS)
Budnik, Frank; Morley, Trevor
2007-01-01
This paper reports on the navigation activities during Rosetta s Mars swing-by. It covers the Mars approach phase starting after a deterministic deep-space maneuver in September 2006, the swing-by proper on 25 February 2007, and ends with another deterministic deep-space maneuver in April 2007 which was also foreseen to compensate any navigation error. Emphasis is put on the orbit determination and prediction set-up and the evolution of the targeting estimates in the B-plane and their adjustments by trajectory correction maneuvers.
Free-Swinging Failure Tolerance for Robotic Manipulators
NASA Technical Reports Server (NTRS)
English, James
1997-01-01
Under this GSRP fellowship, software-based failure-tolerance techniques were developed for robotic manipulators. The focus was on failures characterized by the loss of actuator torque at a joint, called free-swinging failures. The research results spanned many aspects of the free-swinging failure-tolerance problem, from preparing for an expected failure to discovery of postfailure capabilities to establishing efficient methods to realize those capabilities. Developed algorithms were verified using computer-based dynamic simulations, and these were further verified using hardware experiments at Johnson Space Center.
45Degree view of one (1) arm of the swing span ...
45-Degree view of one (1) arm of the swing span bridge in the open position. The view shows the continuous bottom chord of the truss. The vertical post and diagonal web members that frame into this bottom chord are connected with single steel pins at each panel point (or joint). The timber track ties, supporting the track, span from truss to truss bottom chords (16' -0') and are supported thereby. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Snyder, M; Tseng, Y H; Brandt, C; Croghan, C; Hanson, S; Constantine, R; Kirby, L
2001-01-01
Intervention studies for persons with dementia present many challenges. This article describes challenges encountered in conducting a glider swing intervention study for persons with dementia and the strategies used to manage the problems encountered. The overall purpose of a quasi-experimental study was to explore the effects of a glider swing intervention on emotions, relaxation, and aggressive behaviors in nursing home residents with dementia. Suggestions for investigators conducting intervention studies for persons with dementia are provided.
Update on the Swinging Atwood's Machine
NASA Astrophysics Data System (ADS)
Tufillaro, Nicholas
2010-03-01
The Swinging Atwood's machine (SAM) is an Atwood's machine where one of the masses is allowed to swing in a plane. There are only a few integrable examples of mechanical systems, and we show that SAM is completely integrable when the mass ratio is three. We also present an overview of recent results that analyze the dynamics of SAM for other mass ratios using the Painleve analysis and Galois theory, which indicate that SAM is non-integrable for other values of mass ratios.
Myths of Teaching the Golf Swing.
ERIC Educational Resources Information Center
Kraft, Robert E.
1987-01-01
This article dispells 11 myths about common teaching practices and misconceptions about the modern golf swing. Each myth is counterbalanced by facts presented by researchers about appropriate movements, skills, and practices. (CB)
... who did not warm up before playing. The golf swing is broken down into four phases: backswing, downswing, ... is the repetitive nature of this sport. The golf swing involves repetitive, high-velocity movement of the neck, ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, JA; Sumida, K; Herm, ZR
Two representative metal-organic frameworks, Zn4O(BTB)(2)(BTB3- = 1,3,5-benzenetribenzoate; MOF-177) and Mg-2(dobdc) (dobdc(4-) = 1,4-dioxido-2,5-benzenedicarboxylate; Mg-MOF-74, CPO-27-Mg), are evaluated in detail for their potential use in post-combustion CO2 capture via temperature swing adsorption (TSA). Low-pressure single-component CO2 and N-2 adsorption isotherms were measured every 10 degrees C from 20 to 200 degrees C, allowing the performance of each material to be analyzed precisely. In order to gain a more complete understanding of the separation phenomena and the thermodynamics of CO2 adsorption, the isotherms were analyzed using a variety of methods. With regard to the isosteric heat of CO2 adsorption, Mg-2(dobdc) exhibits anmore » abrupt drop at loadings approaching the saturation of the Mg2+ sites, which has significant implications for regeneration in different industrial applications. The CO2/N-2 selectivities were calculated using ideal adsorbed solution theory (IAST) for MOF-177, Mg-2(dobdc), and zeolite NaX, and working capacities were estimated using a simplified TSA model. Significantly, MOF-177 fails to exhibit a positive working capacity even at regeneration temperatures as high as 200 degrees C, while Mg-2(dobdc) reaches a working capacity of 17.6 wt% at this temperature. Breakthrough simulations were also performed for the three materials, demonstrating the superior performance of Mg-2(dobdc) over MOF-177 and zeolite NaX. These results show that the presence of strong CO2 adsorption sites is essential for a metal-organic framework to be of utility in post-combustion CO2 capture via a TSA process, and present a methodology for the evaluation of new metal-organic frameworks via analysis of single-component gas adsorption isotherms.« less
16. Detail view of swing span track manual alignment and ...
16. Detail view of swing span track manual alignment and locking mechanisms, looking southwest - India Point Railroad Bridge, Spanning Seekonk River between Providence & East Providence, Providence, Providence County, RI
Analysis on temperature dependent current mechanism of tunnel field-effect transistors
NASA Astrophysics Data System (ADS)
Lee, Junil; Kwon, Dae Woong; Kim, Hyun Woo; Kim, Jang Hyun; Park, Euyhwan; Park, Taehyung; Kim, Sihyun; Lee, Ryoongbin; Lee, Jong-Ho; Park, Byung-Gook
2016-06-01
In this paper, the total drain current (I D) of a tunnel FET (TFET) is decomposed into each current component with different origins to analyze the I D formation mechanisms of the TFET as a function of gate voltage (V GS). Transfer characteristics are firstly extracted with fabricated Silicon channel TFETs (Si TFETs) and silicon germanium channel TFETs (SiGe TFETs) at various temperatures. The subthreshold swings (SS) of both Si TFETs and SiGe TFETs get degraded and the SSs of SiGe TFETs get degraded more as temperature becomes higher. Then, all the I Ds measured at various temperatures are decomposed into each current component through technology computer aided design (TCAD) simulations with a good agreement with experimental data. As a result, it is revealed that Shockley-Read-Hall (SRH) recombination mainly contribute to the I D of a TFET before band to band tunneling (BTBT) occurs. Furthermore, the SS degradation by high temperature is explained successfully by the SRH recombination with electric field dependence.
1. VIEW OF SWING BRIDGE FROM KEDZIE AVENUE BRIDGE, LOOKING ...
1. VIEW OF SWING BRIDGE FROM KEDZIE AVENUE BRIDGE, LOOKING EAST. - Chicago, Madison & Northern Railroad, Sanitary & Ship Canal Bridge, Spanning Sanitary & Ship Canal, east of Kedzie Avenue, Chicago, Cook County, IL
A Study on Multi-Swing Stability Analysis of Power System using Damping Rate Inversion
NASA Astrophysics Data System (ADS)
Tsuji, Takao; Morii, Yuki; Oyama, Tsutomu; Hashiguchi, Takuhei; Goda, Tadahiro; Nomiyama, Fumitoshi; Kosugi, Narifumi
In recent years, much attention is paid to the nonlinear analysis method in the field of stability analysis of power systems. Especially for the multi-swing stability analysis, the unstable limit cycle has an important meaning as a stability margin. It is required to develop a high speed calculation method of stability boundary regarding multi-swing stability because the real-time calculation of ATC is necessary to realize the flexible wheeling trades. Therefore, the authors have developed a new method which can calculate the unstable limit cycle based on damping rate inversion method. Using the unstable limit cycle, it is possible to predict the multi-swing stability at the time when the fault transmission line is reclosed. The proposed method is tested in Lorenz equation, single-machine infinite-bus system model and IEEJ WEST10 system model.
Partial feedback linearization control for 3-D underactuated overhead crane systems.
Wu, Xianqing; He, Xiongxiong
2016-11-01
In this paper, a novel anti-swing control method is proposed for 3-dimensional (3-D) underactuated overhead crane systems, which guarantees fast transportation and efficient swing suppression. Specifically, to increase the performance of the payload swing suppression, a swing-suppressing element is introduced, based on which a novel positioning error signal is constructed. Then, a new control method is developed, and the overall system is divided into two subsystems. The stability analysis of the two subsystems and the overall system is given. In addition, the convergence of the system states is proved. Simulation results are provided to demonstrate the superior performance of the proposed controller over the existing controllers. Meanwhile, the practical performance of the proposed controller is experimentally validated on a portable overhead crane test-bed. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Pang, Marco Y C; Yang, Jaynie F
2002-07-01
Humans can make smooth, continuous transitions in walking direction from forward to backward. Thus, the processing of sensory input must allow a similar continuum of possibilities. Hip extension and reduced load are two important conditions that control the transition from the stance to swing phase during forward stepping in human infants. The purpose of this study was to determine whether the same factors also regulate the initiation of the swing phase in other directions of stepping. Thirty-seven infants between the ages of 5 and 13 months were studied during supported forward and sideways stepping on a treadmill. Disturbances were elicited by placing a piece of cardboard under the foot and pulling the cardboard in different directions. In this way, the leg was displaced in a particular direction and simultaneously unloaded. We observed whether the swing phase was immediately initiated after the application of disturbances in various directions. Electromyography, vertical ground reaction forces, and hip motion in frontal and sagittal planes were recorded. The results showed that the most potent sensory input to initiate the swing phase depends on the direction of stepping. Although low load was always necessary to initiate swing for all directions of walking, the preferred hip position was always one directly opposite the direction of walking. The results indicated the presence of selective gating of sensory input from the legs as a function of the direction of stepping.
Hip joint torques during the golf swing of young and senior healthy males.
Foxworth, Judy L; Millar, Audrey L; Long, Benjamin L; Way, Michael; Vellucci, Matthew W; Vogler, Joshua D
2013-09-01
Descriptive, laboratory study. To compare the 3-D hip torques during a golf swing between young and senior healthy male amateur golfers. The secondary purpose was to compare the 3-D hip joint torques between the trail leg and lead leg. The generation of hip torques from the hip musculature is an important aspect of the golf swing. Golf is a very popular activity, and estimates of hip torques during the golf swing have not been reported. Twenty healthy male golfers were divided into a young group (mean ± SD age, 25.1 ± 3.1 years) and a senior group (age, 56.9 ± 4.7 years). All subjects completed 10 golf swings using their personal driver. A motion capture system and force plates were used to obtain kinematic and kinetic data. Inverse dynamic analyses were used to calculate 3-D hip joint torques of the trail and lead limbs. Two-way analyses of covariance (group by leg), with club-head velocity as a covariate, were used to compare peak hip torques between groups and limbs. Trail-limb hip external rotator torque was significantly greater in the younger group compared to the senior group, and greater in the trail leg versus the lead leg. When adjusting for club-head velocity, young and senior healthy male amateur golfers generated comparable hip torques during a golf swing, with the exception of the trail-limb hip external rotator torque. The largest hip torque found was the trail-limb hip extensor torque.
High Power Amplifier and Power Supply
NASA Technical Reports Server (NTRS)
Duong, Johnny; Stride, Scot; Harvey, Wayne; Haque, Inam; Packard, Newton; Ng, Quintin; Ispirian, Julie Y.; Waian, Christopher; Janes, Drew
2008-01-01
A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.
Kinematic analysis of the golf swing in men and women experienced golfers.
Egret, C I; Nicolle, B; Dujardin, F H; Weber, J; Chollet, D
2006-06-01
Golf has become an increasingly popular sport, which is enjoyed by both men and women. This paper addresses the question what differences may exist between men and women golfers. The purpose of this study is to analyze the kinematic pattern of the golf swing in both men and women experienced golfers. Seven male and five female golfers participated in the study. The measurements of kinematic data during swing were obtained with the optoelectronic system VICON (Oxford's Metric, Oxford, UK) with five cameras operating at 50 frames per second. Clubhead speed was measured using a radar system (Bell-Tronics, Ltd, Covington, USA). A Mann-Whitney test (p = 0.05) showed that the women seem to produce a wide swing with larger hip and shoulder joint rotation angles at the top of the backswing. Men flexed their left knee more during the backswing, this may promote a greater weight transfer to the right side. Nevertheless, these two kinematic patterns showed no significant differences in the clubhead speed. Men probably used their increased knee flexion to compensate for their muscular and articular suppleness which is less than that of the women. The results of this study show that there is a specific swing for women.
Centre of pressure patterns in the golf swing: individual-based analysis.
Ball, Kevin; Best, Russell
2012-06-01
Weight transfer has been identified as important in group-based analyses. The aim of this study was to extend this work by examining the importance of weight transfer in the golf swing on an individual basis. Five professional and amateur golfers performed 50 swings with the driver, hitting a ball into a net. The golfer's centre of pressure position and velocity, parallel with the line of shot, were measured by two force plates at eight swing events that were identified from high-speed video. The relationships between these parameters and club head velocity at ball contact were examined using regression statistics. The results did support the use of group-based analysis, with all golfers returning significant relationships. However, results were also individual-specific, with golfers returning different combinations of significant factors. Furthermore, factors not identified in group-based analysis were significant on an individual basis. The most consistent relationship was a larger weight transfer range associated with a larger club head velocity (p < 0.05). All golfers also returned at least one significant relationship with rate of weight transfer at swing events (p < 0.01). Individual-based analysis should form part of performance-based biomechanical analysis of sporting skills.
Analysis of the 5 iron golf swing when hitting for maximum distance.
Healy, Aoife; Moran, Kieran A; Dickson, Jane; Hurley, Cillian; Smeaton, Alan F; O'Connor, Noel E; Kelly, Philip; Haahr, Mads; Chockalingam, Nachiappan
2011-07-01
Most previous research on golf swing mechanics has focused on the driver club. The aim of this study was to identify the kinematic factors that contribute to greater hitting distance when using the 5 iron club. Three-dimensional marker coordinate data were collected (250 Hz) to calculate joint kinematics at eight key swing events, while a swing analyser measured club swing and ball launch characteristics. Thirty male participants were assigned to one of two groups, based on their ball launch speed (high: 52.9 ± 2.1 m · s(-1); low: 39.9 ± 5.2 m · s(-1)). Statistical analyses were used to identify variables that differed significantly between the two groups. Results showed significant differences were evident between the two groups for club face impact point and a number of joint angles and angular velocities, with greater shoulder flexion and less left shoulder internal rotation in the backswing, greater extension angular velocity in both shoulders at early downswing, greater left shoulder adduction angular velocity at ball contact, greater hip joint movement and X Factor angle during the downswing, and greater left elbow extension early in the downswing appearing to contribute to greater hitting distance with the 5 iron club.
Differences in activation properties of the hamstring muscles during overground sprinting.
Higashihara, Ayako; Nagano, Yasuharu; Ono, Takashi; Fukubayashi, Toru
2015-09-01
The purpose of this study was to quantify activation of the biceps femoris (BF) and medial hamstring (MH) during overground sprinting. Lower-extremity kinematics and electromyography (EMG) of the BF and MH were recorded in 13 male sprinters performing overground sprinting at maximum effort. Mean EMG activity was calculated in the early stance, late stance, mid-swing, and late-swing phases. Activation of the BF was significantly greater during the early stance phase than the late stance phase (p<0.01). Activation of the BF muscle was significantly lower during the first half of the mid-swing phase than the other phases (p<0.05). The MH had significantly greater EMG activation relative to its recorded maximum values compared to that for the BF during the late stance (p<0.05) and mid-swing (p<0.01) phases. These results indicate that the BF shows high activation before and after foot contact, while the MH shows high activation during the late stance and mid-swing phases. We concluded that the activation properties of the BF and MH muscles differ within the sprinting gait cycle. Copyright © 2015 Elsevier B.V. All rights reserved.
The ideal chip is not enough: Issues retarding the success of wide band-gap devices
NASA Astrophysics Data System (ADS)
Kaminski, Nando
2017-04-01
Semiconductor chips made from the wide band-gap (WBG) materials silicon carbide (SiC) or gallium nitride (GaN) are already approaching the theoretical limits given by the respective materials. Unfortunately, their advantages over silicon devices cannot be fully exploited due to limitations imposed by the device packaging or the circuitry around the semiconductors. Stray inductances slow down the switching speed and increase losses, packaging materials limit the maximum temperature and the maximum useful temperature swing, and passives limit the maximum switching frequency. All these issues have to be solved or at least minimised to make WBG attractive for a wider range of applications and, consequently, to profit from the economy of scale.
NASA Astrophysics Data System (ADS)
Lee, Sunwoo; Yoon, Seungki; Park, In-Sung; Ahn, Jinho
2009-04-01
We studied the electrical characteristics of an organic field effect transistor (OFET) formed by the hydrogen (H2) and nitrogen (N2) mixed gas treatment of a gate dielectric layer. We also investigated how device mobility is related to the length and width variations of the channel. Aluminum oxide (Al2O3) was used as the gate dielectric layer. After the treatment, the mobility and subthreshold swing were observed to be significantly improved by the decreased hole carrier localization at the interfacial layer between the gate oxide and pentacene channel layers. H2 gas plays an important role in removing the defects of the gate oxide layer at temperatures below 100 °C.
Free-Swinging Failure Tolerance for Robotic Manipulators. Degree awarded by Purdue Univ.
NASA Technical Reports Server (NTRS)
English, James
1997-01-01
Under this GSRP fellowship, software-based failure-tolerance techniques were developed for robotic manipulators. The focus was on failures characterized by the loss of actuator torque at a joint, called free-swinging failures. The research results spanned many aspects of the free-swinging failure-tolerance problem, from preparing for an expected failure to discovery of postfailure capabilities to establishing efficient methods to realize those capabilities. Developed algorithms were verified using computer-based dynamic simulations, and these were further verified using hardware experiments at Johnson Space Center.
Mun, Frederick; Suh, Seung Woo; Park, Hyun-Joon; Choi, Ahnryul
2015-05-14
Understanding the kinematics of the lumbar spine and hip joints during a golf swing is a basic step for identifying swing-specific factors associated with low back pain. The objective of this study was to examine the kinematic relationship between rotational movement of the lumbar spine and hip joints during a golf swing. Fifteen professional golfers participated in this study with employment of six infrared cameras to record their golf swings. Anatomical reference system of the upper torso, pelvis and thigh segments, and the location of each hip and knee joint were defined by the protocols of the kinematic model of previous studies. Lumbar spine and hip joint rotational angle was calculated utilizing the Euler angle method. Cross-correlation and angle-angle plot was used to examine the degree of kinematic relationship between joints. A fairly strong coupling relationship was shown between the lumbar spine and hip rotational movements with an average correlation of 0.81. Leading hip contribution to overall rotation was markedly high in the early stage of the downswing, while the lumbar spine contributed greater towards the end of the downswing; however, the relative contributions of the trailing hip and lumbar spine were nearly equal during the entire downswing. Most of the professional golfers participated in this study used a similar coordination strategy when moving their hips and lumbar spine during golf swings. The rotation of hips was observed to be more efficient in producing the overall rotation during the downswing when compared to the backswing. These results provide quantitative information to better understand the lumbar spine and hip joint kinematic characteristics of professional golfers. This study will have great potential to be used as a normal control data for the comparison with kinematic information among golfers with low back pain and for further investigation of golf swing-specific factors associated with injury.
SU-E-T-465: Dose Calculation Method for Dynamic Tumor Tracking Using a Gimbal-Mounted Linac
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sugimoto, S; Inoue, T; Kurokawa, C
Purpose: Dynamic tumor tracking using the gimbal-mounted linac (Vero4DRT, Mitsubishi Heavy Industries, Ltd., Japan) has been available when respiratory motion is significant. The irradiation accuracy of the dynamic tumor tracking has been reported to be excellent. In addition to the irradiation accuracy, a fast and accurate dose calculation algorithm is needed to validate the dose distribution in the presence of respiratory motion because the multiple phases of it have to be considered. A modification of dose calculation algorithm is necessary for the gimbal-mounted linac due to the degrees of freedom of gimbal swing. The dose calculation algorithm for the gimbalmore » motion was implemented using the linear transformation between coordinate systems. Methods: The linear transformation matrices between the coordinate systems with and without gimbal swings were constructed using the combination of translation and rotation matrices. The coordinate system where the radiation source is at the origin and the beam axis along the z axis was adopted. The transformation can be divided into the translation from the radiation source to the gimbal rotation center, the two rotations around the center relating to the gimbal swings, and the translation from the gimbal center to the radiation source. After operating the transformation matrix to the phantom or patient image, the dose calculation can be performed as the no gimbal swing. The algorithm was implemented in the treatment planning system, PlanUNC (University of North Carolina, NC). The convolution/superposition algorithm was used. The dose calculations with and without gimbal swings were performed for the 3 × 3 cm{sup 2} field with the grid size of 5 mm. Results: The calculation time was about 3 minutes per beam. No significant additional time due to the gimbal swing was observed. Conclusions: The dose calculation algorithm for the finite gimbal swing was implemented. The calculation time was moderate.« less
Lumbar Corsets Can Decrease Lumbar Motion in Golf Swing
Hashimoto, Koji; Miyamoto, Kei; Yanagawa, Takashi; Hattori, Ryo; Aoki, Takaaki; Matsuoka, Toshio; Ohno, Takatoshi; Shimizu, Katsuji
2013-01-01
Swinging a golf club includes the rotation and extension of the lumbar spine. Golf-related low back pain has been associated with degeneration of the lumbar facet and intervertebral discs, and with spondylolysis. Reflective markers were placed directly onto the skin of 11young male amateur golfers without a previous history of back pain. Using a VICON system (Oxford Metrics, U.K.), full golf swings were monitored without a corset (WOC), with a soft corset (SC), and with a hard corset (HC), with each subject taking 3 swings. Changes in the angle between the pelvis and the thorax (maximum range of motion and angular velocity) in 3 dimensions (lumbar rotation, flexion-extension, and lateral tilt) were analyzed, as was rotation of the hip joint. Peak changes in lumbar extension and rotation occurred just after impact with the ball. The extension angle of the lumbar spine at finish was significantly lower under SC (38°) or HC (28°) than under WOC (44°) conditions (p < 0.05). The maximum angular velocity after impact was significantly smaller under HC (94°/sec) than under SC (177°/sec) and WOC (191° /sec) conditions, as were the lumbar rotation angles at top and finish. In contrast, right hip rotation angles at top showed a compensatory increase under HC conditions. Wearing a lumbar corset while swinging a golf club can effectively decrease lumbar extension and rotation angles from impact until the end of the swing. These effects were significantly enhanced while wearing an HC. Key points Rotational and extension forces on the lumbar spine may cause golf-related low back pain Wearing lumbar corsets during a golf swing can effectively decrease lumbar extension and rotation angles and angular velocity. Wearing lumbar corsets increased the rotational motion of the hip joint while reducing the rotation of the lumbar spine. PMID:24149729
Lumbar corsets can decrease lumbar motion in golf swing.
Hashimoto, Koji; Miyamoto, Kei; Yanagawa, Takashi; Hattori, Ryo; Aoki, Takaaki; Matsuoka, Toshio; Ohno, Takatoshi; Shimizu, Katsuji
2013-01-01
Swinging a golf club includes the rotation and extension of the lumbar spine. Golf-related low back pain has been associated with degeneration of the lumbar facet and intervertebral discs, and with spondylolysis. Reflective markers were placed directly onto the skin of 11young male amateur golfers without a previous history of back pain. Using a VICON system (Oxford Metrics, U.K.), full golf swings were monitored without a corset (WOC), with a soft corset (SC), and with a hard corset (HC), with each subject taking 3 swings. Changes in the angle between the pelvis and the thorax (maximum range of motion and angular velocity) in 3 dimensions (lumbar rotation, flexion-extension, and lateral tilt) were analyzed, as was rotation of the hip joint. Peak changes in lumbar extension and rotation occurred just after impact with the ball. The extension angle of the lumbar spine at finish was significantly lower under SC (38°) or HC (28°) than under WOC (44°) conditions (p < 0.05). The maximum angular velocity after impact was significantly smaller under HC (94°/sec) than under SC (177°/sec) and WOC (191° /sec) conditions, as were the lumbar rotation angles at top and finish. In contrast, right hip rotation angles at top showed a compensatory increase under HC conditions. Wearing a lumbar corset while swinging a golf club can effectively decrease lumbar extension and rotation angles from impact until the end of the swing. These effects were significantly enhanced while wearing an HC. Key pointsRotational and extension forces on the lumbar spine may cause golf-related low back painWearing lumbar corsets during a golf swing can effectively decrease lumbar extension and rotation angles and angular velocity.Wearing lumbar corsets increased the rotational motion of the hip joint while reducing the rotation of the lumbar spine.
Agricultural and Ranching area, Rio Sao Francisco, Brazil
NASA Technical Reports Server (NTRS)
1990-01-01
This agricultural and Ranching area, Rio Sao Francisco, Brazil (13.0S, 43.5W) has been under study for several years. See scene STS-31-92-045 for comparison. This area has many small single family subsistence farms, large square and rectangular commercial farms and pastures for livestock grazing. Over the several years of observation, the number and size of farms has increased and center-pivot, swing-arm irrigation systems have been installed.
Robust, Thin Optical Films for Extreme Environments
NASA Technical Reports Server (NTRS)
2006-01-01
The environment of space presents scientists and engineers with the challenges of a harsh, unforgiving laboratory in which to conduct their scientific research. Solar astronomy and X-ray astronomy are two of the more challenging areas into which NASA scientists delve, as the optics for this high-tech work must be extremely sensitive and accurate, yet also be able to withstand the battering dished out by radiation, extreme temperature swings, and flying debris. Recent NASA work on this rugged equipment has led to the development of a strong, thin film for both space and laboratory use.
8. 320 FOOT LEVEL, SWING ARM NINE SHOWING BACK SIDE ...
8. 320 FOOT LEVEL, SWING ARM NINE SHOWING BACK SIDE OF ENVIRONMENTAL CHAMBER (WHITE ROOM). WHITE ROOM MADE CONNECTION WITH CAPSULE ON LAUNCH VEHICLE. - Mobile Launcher One, Kennedy Space Center, Titusville, Brevard County, FL
Swinging into Pendulums with a Background.
ERIC Educational Resources Information Center
Barrow, Lloyd H.; Cook, Julie
1993-01-01
Explains reasons why students have misconceptions concerning pendulum swings. Presents a series of 10 pendulum task cards to provide middle-school students with a solid mental scaffolding upon which to build their knowledge of kinetic energy and pendulums. (PR)
29. SOUTH SWING SPAN, SHOWING REPRESENTATIVE REDUCTION GEAR/MOTOR DRIVE UNIT ...
29. SOUTH SWING SPAN, SHOWING REPRESENTATIVE REDUCTION GEAR/MOTOR DRIVE UNIT (CENTER) AND WEDGE MOTOR UNIT (RIGHT). - George P. Coleman Memorial Bridge, Spanning York River at U.S. Route 17, Yorktown, York County, VA
Noether symmetries and the Swinging Atwood Machine
NASA Astrophysics Data System (ADS)
Moreira, I. C.; Almeida, M. A.
1991-07-01
In this work we apply the Noether theorem with generalised symmetries for discussing the integrability of the Swinging Atwood Machine (SAM) model. We analyse also the limitations of this procedure and compare it with the Yoshida method.
Skill Analysis of the Wrist Release in the Golf Swings Utilizing Shaft Elasticity
NASA Astrophysics Data System (ADS)
Suzuki, Soichiro; Hoshino, Yohei; Kobayashi, Yukinori
This study analyzes the skill component of the wrist release in the golf swing by employing a three-dimensional dynamic model considering vibration of the club shaft. It is observed that professional and expert golfers relax their wrists in the swing motion as a "natural" or "late" release. Thus, the relationship between the timing of the wrist release and the shaft vibration is examined in this study. First, it is demonstrated that "natural release" at the zero-crossing point of the bending vibration of the shaft efficiently increases the head speed at impact. In the next step, the "late hitting" condition is imposed upon the model. It is demonstrated that "late hitting" could further improve the efficiency of the swing motion. Finally, the skill component in the wrist release for the long drive is experimentally verified by measuring the movement of the wrist and the dynamic deformation of the shaft during the downswing.
LeMoyne, Robert; Mastroianni, Timothy
2016-08-01
Natural gait consists of synchronous and rhythmic patterns for both the lower and upper limb. People with hemiplegia can experience reduced arm swing, which can negatively impact the quality of gait. Wearable and wireless sensors, such as through a smartphone, have demonstrated the ability to quantify various features of gait. With a software application the smartphone (iPhone) can function as a wireless gyroscope platform capable of conveying a gyroscope signal recording as an email attachment by wireless connectivity to the Internet. The gyroscope signal recordings of the affected hemiplegic arm with reduced arm swing arm and the unaffected arm are post-processed into a feature set for machine learning. Using a multilayer perceptron neural network a considerable degree of classification accuracy is attained to distinguish between the affected hemiplegic arm with reduced arm swing arm and the unaffected arm.
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad
2009-01-01
Electronic systems designed for use in deep space and planetary exploration missions are expected to encounter extreme temperatures and wide thermal swings. Silicon-based devices are limited in their wide-temperature capability and usually require extra measures, such as cooling or heating mechanisms, to provide adequate ambient temperature for proper operation. Silicon-On-Insulator (SOI) technology, on the other hand, lately has been gaining wide spread use in applications where high temperatures are encountered. Due to their inherent design, SOI-based integrated circuit chips are able to operate at temperatures higher than those of the silicon devices by virtue of reducing leakage currents, eliminating parasitic junctions, and limiting internal heating. In addition, SOI devices provide faster switching, consume less power, and offer improved radiation-tolerance. Very little data, however, exist on the performance of such devices and circuits under cryogenic temperatures. In this work, the performance of an SOI bootstrapped, full-bridge driver integrated circuit was evaluated under extreme temperatures and thermal cycling. The investigations were carried out to establish a baseline on the functionality and to determine suitability of this device for use in space exploration missions under extreme temperature conditions.
Ustinova, Ksenia I; Feldman, Anatol G; Levin, Mindy F
2013-06-01
The paretic arm of subjects with stroke has a decreased ability to quickly adapt to and recover from perturbations during rhythmical arm swinging. We investigated whether bilateral coupling in the synchronous motion of two arms may facilitate the restoration of rhythmical movement of the paretic arm in subjects with chronic hemiparesis due to stroke. While standing, stroke and age-matched healthy (control) subjects swung one or both arms synchronously at ~0.8 Hz from the shoulder joints. In randomly selected cycles, one arm was transiently arrested by an electromagnetic device when moving forward or backward. In the control group, bilateral swinging resumed faster than unilateral swinging regardless of which arm was perturbed. In the stroke group, this effect was observed only when the perturbation was applied to the paretic arm, suggesting that the motion of the non-paretic arm accelerated the recovery from perturbation of the paretic arm. In addition, bilateral swinging resumed after reduced anterior-posterior excursions of both arms in stroke subjects. Results confirm previous findings that bilateral swinging is normally guided by central changes in the referent configuration of the two arms that function as a single unit. As a consequence, both arms cooperate in recovery from perturbation of motion applied to one arm. Results also suggest that stroke-related brain damage alters the symmetry of bilateral interaction, resulting in deficits of inter-manual cooperative action. The involvement of the non-paretic arm could be beneficial for the recovery of swinging of both arms and may also facilitate movements of the paretic arm in certain tasks.
Organic antireflective coatings for 193-nm lithography
NASA Astrophysics Data System (ADS)
Trefonas, Peter, III; Blacksmith, Robert F.; Szmanda, Charles R.; Kavanagh, Robert J.; Adams, Timothy G.; Taylor, Gary N.; Coley, Suzanne; Pohlers, Gerd
1999-06-01
Organic anti-reflective coatings (ARCs) continue to play an important role in semiconductor manufacturing. These materials provide a convenient means of greatly reducing the resist photospeed swing and reflective notching. In this paper, we describe a novel class of ARC materials optimized for lithographic applications using 193 nm exposure tools. These ARCs are based upon polymers containing hydroxyl-alkyl methacrylate monomers for crosslinkable sites, styrene for a chromophore at 193 nm, and additional alkyl-methacrylate monomers as property modifiers. A glycouril crosslinker and a thermally-activated acidic catalyst provide a route to forming an impervious crosslinked film activate data high bake temperatures. ARC compositions can be adjusted to optimize the film's real and imaginary refractive indices. Selection of optimal target indices for 193 nm lithographic processing through simulations is described. Potential chromophores for 193 nm were explored using ZNDO modeling. We show how these theoretical studies were combined with material selection criteria to yield a versatile organic anti-reflectant film, Shipley 193 G0 ARC. Lithographic process data indicates the materials is capable of supporting high resolution patterning, with the line features displaying a sharp resist/ARC interface with low line edge roughness. The resist Eo swing is successfully reduced from 43 percent to 6 percent.
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad
2011-01-01
Data acquisition and control systems depend on timing signals for proper operation and required accuracy. These clocked signals are typically provided by some form of an oscillator set to produce a repetitive, defined signal at a given frequency. Crystal oscillators are commonly used because they are less expensive, smaller, and more reliable than other types of oscillators. Because of the inherent characteristics of the crystal, the oscillators exhibit excellent frequency stability within the specified range of operational temperature. In some cases, however, some compensation techniques are adopted to further improve the thermal stability of a crystal oscillator. Very limited data exist on the performance and reliability of commercial-off-the-shelf (COTS) crystal oscillators at temperatures beyond the manufacturer's specified operating temperature range. This information is very crucial if any of these parts were to be used in circuits designed for use in space exploration missions where extreme temperature swings and thermal cycling are encountered. This report presents the results of the work obtained on the operation of Silicon Laboratories crystal oscillator, type Si530, under specified and extreme ambient temperatures.
Chestovich, Paul J; McNicoll, Christopher F; Ingalls, Nichole K; Kuhls, Deborah A; Fraser, Douglas R; Morrissey, Shawna L; Fildes, John J
2018-01-01
Fellowship trainees in acute care surgery require experience in the management of complex and operative trauma cases. Trauma center staffing usually follows standard 12-hour or 24-hour shifts, with resident and fellow trainees following a similar schedule. Although trauma admissions can be generally unpredictable, we analyzed temporal trends of trauma patient arrival times to determine the best time frame to maximize trainee experience during each day. We reviewed 10 years (2007-2016) of trauma registry data for blunt and penetrating trauma activations. Hourly volumetric trends were observed, and three specific events were chosen for detailed analysis: (1) trauma activation with Injury Severity Score (ISS) greater than 15, (2) laparotomy for trauma, and (3) thoracotomy for trauma. A retrospective shift log was created, which included day (7:00 AM to 7:00 PM), night (7:00 PM to 7:00 AM), and swing (noon to midnight) shifts. A swing shift was chosen because it captures the peak volume for all three events. Means and 95% confidence intervals were calculated, and comparisons were made between shifts using the Wilcoxon matched-pairs signed rank test with Bonferroni correction, and p less than 0.05 considered significant. During the 10-year study period, 28,287 patients were treated at our trauma center. This included the evaluation and management of 7,874 patients with ISS greater than 15, performance of 1,766 laparotomies, and 392 thoracotomies for trauma. Swing shift was superior to both day and night shifts for ISS greater than 15 (p < 0.001). Both swing and night shifts were superior to day shift for laparotomies (p < 0.001). Swing shift was superior to both day shift (p < 0.001) and night shift (p = 0.031). Shifts with the highest yield of ISS greater than 15, laparotomies, and thoracotomies include night and swing shifts on Fridays and Saturdays. Projected experience of acute care surgery fellows in managing complex trauma patients increases with the integration of swing shifts into the schedule. Daily trauma volume follows a temporal pattern which, when used correctly, can increase trainee exposure to complex and operative trauma cases. We encourage other centers to analyze their volume and adjust trainee schedules accordingly to maximize their educational experience. Therapeutic study, level IV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Jinxiong; Yuan, Hongtao; Meng, Mengmeng
Identifying new two-dimensional (2D) materials with both high carrier mobility and a large electronic band gap is critical for novel electronics and optoelectronics applications. Here, we demonstrated a new air-stable ultrahigh-mobility layered Bi 2O 2Se semiconductor with a large band gap of ~ 0.8 eV and a low effective mass of ~ 0.14 m 0. High-quality 2D Bi2O2Se crystals with a thickness down to a monolayer and a domain size greater than 200 μm were readily grown by chemical vapor deposition (CVD). Size-tunable band gap of Bi 2O 2Se was found to increase as thinning down to the monolayer duemore » to the quantum confinement effect. An ultrahigh Hall mobility of > 20,000 cm 2 V -1 s -1 was achieved in as-grown Bi 2O 2Se flakes at 1.9 K, which allows for the observation of Shubnikov–de Haas quantum oscillations. Top-gated field-effect transistors based on CVD-grown 2D Bi 2O 2Se crystals (down to bilayer) exhibited high Hall mobility (up to 450 cm 2 V -1 s -1), large current on/off ratios (>106) and near-ideal subthreshold swings (~65 mV/dec) at room temperature. Our results make the high-mobility 2D Bi 2O 2Se semiconductor a promising candidate for future high-speed and low-power electronic applications.« less
Wu, Jinxiong; Yuan, Hongtao; Meng, Mengmeng; ...
2017-04-03
Identifying new two-dimensional (2D) materials with both high carrier mobility and a large electronic band gap is critical for novel electronics and optoelectronics applications. Here, we demonstrated a new air-stable ultrahigh-mobility layered Bi 2O 2Se semiconductor with a large band gap of ~ 0.8 eV and a low effective mass of ~ 0.14 m 0. High-quality 2D Bi2O2Se crystals with a thickness down to a monolayer and a domain size greater than 200 μm were readily grown by chemical vapor deposition (CVD). Size-tunable band gap of Bi 2O 2Se was found to increase as thinning down to the monolayer duemore » to the quantum confinement effect. An ultrahigh Hall mobility of > 20,000 cm 2 V -1 s -1 was achieved in as-grown Bi 2O 2Se flakes at 1.9 K, which allows for the observation of Shubnikov–de Haas quantum oscillations. Top-gated field-effect transistors based on CVD-grown 2D Bi 2O 2Se crystals (down to bilayer) exhibited high Hall mobility (up to 450 cm 2 V -1 s -1), large current on/off ratios (>106) and near-ideal subthreshold swings (~65 mV/dec) at room temperature. Our results make the high-mobility 2D Bi 2O 2Se semiconductor a promising candidate for future high-speed and low-power electronic applications.« less
How joint torques affect hamstring injury risk in sprinting swing-stance transition.
Sun, Yuliang; Wei, Shutao; Zhong, Yunjian; Fu, Weijie; Li, Li; Liu, Yu
2015-02-01
The potential mechanisms of hamstring strain injuries in athletes are not well understood. The study, therefore, was aimed at understanding hamstring mechanics by studying loading conditions during maximum-effort overground sprinting. Three-dimensional kinematics and ground reaction force data were collected from eight elite male sprinters sprinting at their maximum effort. Maximal isometric torques of the hip and knee were also collected. Data from the sprinting gait cycle were analyzed via an intersegmental dynamics approach, and the different joint torque components were calculated. During the initial stance phase, the ground reaction force passed anteriorly to the knee and hip, producing an extension torque at the knee and a flexion torque at the hip joint. Thus, the active muscle torque functioned to produce flexion torque at the knee and extension torque at the hip. The maximal muscle torque at the knee joint was 1.4 times the maximal isometric knee flexion torque. During the late swing phase, the muscle torque counterbalanced the motion-dependent torque and acted to flex the knee joint and extend the hip joint. The loading conditions on the hamstring muscles were similar to those of the initial stance phase. During both the initial stance and late swing phases, the large passive torques at both the knee and hip joints acted to lengthen the hamstring muscles. The active muscle torques generated mainly by the hamstrings functioned to counteract those passive effects. As a result, during sprinting or high-speed locomotion, the hamstring muscles may be more susceptible to high risk of strain injury during these two phases.
Laser High-Cycle Thermal Fatigue of Pulse Detonation Engine Combustor Materials Tested
NASA Technical Reports Server (NTRS)
Zhu, Dong-Ming; Fox, Dennis S.; Miller, Robert A.
2001-01-01
Pulse detonation engines (PDE's) have received increasing attention for future aerospace propulsion applications. Because the PDE is designed for a high-frequency, intermittent detonation combustion process, extremely high gas temperatures and pressures can be realized under the nearly constant-volume combustion environment. The PDE's can potentially achieve higher thermodynamic cycle efficiency and thrust density in comparison to traditional constant-pressure combustion gas turbine engines (ref. 1). However, the development of these engines requires robust design of the engine components that must endure harsh detonation environments. In particular, the detonation combustor chamber, which is designed to sustain and confine the detonation combustion process, will experience high pressure and temperature pulses with very short durations (refs. 2 and 3). Therefore, it is of great importance to evaluate PDE combustor materials and components under simulated engine temperatures and stress conditions in the laboratory. In this study, a high-cycle thermal fatigue test rig was established at the NASA Glenn Research Center using a 1.5-kW CO2 laser. The high-power laser, operating in the pulsed mode, can be controlled at various pulse energy levels and waveform distributions. The enhanced laser pulses can be used to mimic the time-dependent temperature and pressure waves encountered in a pulsed detonation engine. Under the enhanced laser pulse condition, a maximum 7.5-kW peak power with a duration of approximately 0.1 to 0.2 msec (a spike) can be achieved, followed by a plateau region that has about one-fifth of the maximum power level with several milliseconds duration. The laser thermal fatigue rig has also been developed to adopt flat and rotating tubular specimen configurations for the simulated engine tests. More sophisticated laser optic systems can be used to simulate the spatial distributions of the temperature and shock waves in the engine. Pulse laser high-cycle thermal fatigue behavior has been investigated on a flat Haynes 188 alloy specimen, under the test condition of 30-Hz cycle frequency (33-msec pulse period and 10-msec pulse width including a 0.2-msec pulse spike; ref. 4). Temperature distributions were calculated with one-dimensional finite difference models. The calculations show that that the 0.2-msec pulse spike can cause an additional 40 C temperature fluctuation with an interaction depth of 0.08 mm near the specimen surface region. This temperature swing will be superimposed onto the temperature swing of 80 C that is induced by the 10-msec laser pulse near the 0.53-mm-deep surface interaction region.
Risk Factors for Knee Injury in Golf: A Systematic Review.
Baker, Matthew L; Epari, Devakar R; Lorenzetti, Silvio; Sayers, Mark; Boutellier, Urs; Taylor, William R
2017-12-01
Golf is commonly considered a low-impact sport that carries little risk of injury to the knee and is generally allowed following total knee arthroplasty (TKA). Kinematic and kinetic studies of the golf swing have reported results relevant to the knee, but consensus as to the loads experienced during a swing and how the biomechanics of an individual's technique may expose the knee to risk of injury is lacking. Our objective was to establish (1) the prevalence of knee injury resulting from participation in golf and (2) the risk factors for knee injury from a biomechanical perspective, based on an improved understanding of the internal loading conditions and kinematics that occur in the knee from the time of addressing the ball to the end of the follow-through. A systematic literature search was conducted to determine the injury rate, kinematic patterns, loading, and muscle activity of the knee during golf. A knee injury prevalence of 3-18% was established among both professional and amateur players, with no clear dependence on skill level or sex; however, older players appear at greater risk of injury. Studies reporting kinematics indicate that the lead knee is exposed to a complex series of motions involving rapid extension and large magnitudes of tibial internal rotation, conditions that may pose risks to the structures of a natural knee or TKA. To date, the loads experienced by the lead knee during a golf swing have been reported inconsistently in the literature. Compressive loads ranging from 100 to 440% bodyweight have been calculated and measured using methods including inverse dynamics analysis and instrumented knee implants. Additionally, the magnitude of loading appears to be independent of the club used. This review is the first to highlight the lack of consensus regarding knee loading during the golf swing and the associated risks of injury. Results from the literature suggest the lead knee is subject to a higher magnitude of stress and more demanding motions than the trail knee. Therefore, recommendations regarding return to golf following knee injury or surgical intervention should carefully consider the laterality of the injury.
Methods of and system for swing damping movement of suspended objects
Jones, J.F.; Petterson, B.J.; Strip, D.R.
1991-03-05
A payload suspended from a gantry is swing damped in accordance with a control algorithm based on the periodic motion of the suspended mass or by servoing on the forces induced by the suspended mass. 13 figures.
Critical Access Hospitals (CAH)
... of CAH status? CAH status includes the following benefits: Cost-based reimbursement from Medicare. As of January 1, ... stabilize healthcare facilities’ census and may provide financial benefits. Swing bed services in CAHs are eligible for cost-based reimbursement, while swing bed services in non- ...
8. View of Bronx (east) side of swing span looking ...
8. View of Bronx (east) side of swing span looking north, showing masonry rest pier and truss sway bracing. (Nov. 25, 1988) - University Heights Bridge, Spanning Harlem River at 207th Street & West Harlem Road, New York County, NY
Periodic orbits of the integrable swinging Atwood's machine
NASA Astrophysics Data System (ADS)
Nunes, Ana; Casasayas, Josefina; Tufillaro, Nicholas
1995-02-01
We identify all the periodic orbits of the integrable swinging Atwood's machine by calculating the rotation number of each orbit on its invariant tori in phase space, and also providing explicit formulas for the initial conditions needed to generate each orbit.
NASA Astrophysics Data System (ADS)
Tsai, Chi-Hung; Lai, Mei-Yi; Liu, Che-Wei; Huang, Shiang-Yin; Lin, Che-Yu; Yeh, Jeng-Sheng
In our digital art, we design a folding fan as an interactive magic device. You can use it to play with gas around the world of illusions. Although gas could not be seen in our real world, we still want to interact with it in our illusions by the element of bubble shadows. Opening and swinging the folding fan can blow the bubble shadows away; closing and swinging it can break bubbles. If the magic fan touches the shadow of gas, the bubble shadows will explode and release colorful particles to surround you. Those actions are controlled and located by our circuits with Arduino board.
NASA Astrophysics Data System (ADS)
Zhao, Jieliang; Huang, He; Yan, Shaoze
2017-03-01
Whether for insects or for aircrafts, landing is one of the indispensable links in the verification of airworthiness safety. The mechanisms by which insects achieve a fast and stable landing remain unclear. An intriguing example is provided by honeybees (Apis mellifera ligustica), which use the swinging motion of their abdomen to dissipate residual flying energy and to achieve a smooth, stable, and quick landing. By using a high-speed camera, we observed that touchdown is initiated by honeybees extending their front legs or antennae and then landing softly on a wall. After touchdown, they swing the rest of their bodies until all flying energy is dissipated. We suggested a simplified model with mass-spring dampers for the body of the honeybee and revealed the mechanism of flying energy transfer and dissipation in detail. Results demonstrate that body translation and abdomen swinging help honeybees dissipate residual flying energy and orchestrate smooth landings. The initial kinetic energy of flying is transformed into the kinetic energy of the abdomen's rotary movement. Then, the kinetic energy of rotary movement is converted into thermal energy during the swinging cycle. This strategy provides more insight into the mechanism of insect flying, which further inspires better design on aerial vehicle with better landing performance.
Laughlin, Walter A; Fleisig, Glenn S; Aune, Kyle T; Diffendaffer, Alek Z
2016-01-01
Swing trajectory and ground reaction forces (GRF) of 30 collegiate baseball batters hitting a pitched ball were compared between a standard bat, a bat with extra weight about its barrel, and a bat with extra weight in its handle. It was hypothesised that when compared to a standard bat, only a handle-weighted bat would produce equivalent bat kinematics. It was also hypothesised that hitters would not produce equivalent GRFs for each weighted bat, but would maintain equivalent timing when compared to a standard bat. Data were collected utilising a 500 Hz motion capture system and 1,000 Hz force plate system. Data between bats were considered equivalent when the 95% confidence interval of the difference was contained entirely within ±5% of the standard bat mean value. The handle-weighted bat had equivalent kinematics, whereas the barrel-weighted bat did not. Both weighted bats had equivalent peak GRF variables. Neither weighted bat maintained equivalence in the timing of bat kinematics and some peak GRFs. The ability to maintain swing kinematics with a handle-weighted bat may have implications for swing training and warm-up. However, altered timings of kinematics and kinetics require further research to understand the implications on returning to a conventionally weighted bat.
Brown, Susan J; Selbie, W Scott; Wallace, Eric S
2013-01-01
A common biomechanical feature of a golf swing, described in various ways in the literature, is the interaction between the thorax and pelvis, often termed the X-Factor. There is no consistent method used within golf biomechanics literature however to calculate these segment interactions. The purpose of this study was to examine X-factor data calculated using three reported methods in order to determine the similarity or otherwise of the data calculated using each method. A twelve-camera three-dimensional motion capture system was used to capture the driver swings of 19 participants and a subject specific three-dimensional biomechanical model was created with the position and orientation of each model estimated using a global optimisation algorithm. Comparison of the X-Factor methods showed significant differences for events during the swing (P < 0.05). Data for each kinematic measure were derived as a times series for all three methods and regression analysis of these data showed that whilst one method could be successfully mapped to another, the mappings between methods are subject dependent (P <0.05). Findings suggest that a consistent methodology considering the X-Factor from a joint angle approach is most insightful in describing a golf swing.
Joyce, Christopher; Burnett, Angus; Ball, Kevin
2010-09-01
It is believed that increasing the X-factor (movement of the shoulders relative to the hips) during the golf swing can increase ball velocity at impact. Increasing the X-factor may also increase the risk of low back pain. The aim of this study was to provide recommendations for the three-dimensional (3D) measurement of the X-factor and lower trunk movement during the golf swing. This three-part validation study involved; (1) developing and validating models and related algorithms (2) comparing 3D data obtained during static positions representative of the golf swing to visual estimates and (3) comparing 3D data obtained during dynamic golf swings to images gained from high-speed video. Of particular interest were issues related to sequence dependency. After models and algorithms were validated, results from parts two and three of the study supported the conclusion that a lateral bending/flexion-extension/axial rotation (ZYX) order of rotation was deemed to be the most suitable Cardanic sequence to use in the assessment of the X-factor and lower trunk movement in the golf swing. The findings of this study have relevance for further research examining the X-factor its relationship to club head speed and lower trunk movement and low back pain in golf.
Marta, Sérgio; Silva, Luís; Vaz, João Rocha; Castro, Maria António; Reinaldo, Gustavo; Pezarat-Correia, Pedro
2016-01-01
The aim of this study was to describe and compare the EMG patterns of select lower limb muscles throughout the golf swing, performed with three different clubs, in non-elite middle-aged players. Fourteen golfers performed eight swings each using, in random order, a pitching wedge, 7-iron and 4-iron. Surface electromyography (EMG) was recorded bilaterally from lower limb muscles: tibialis anterior, peroneus longus, gastrocnemius medialis, gastrocnemius lateralis, biceps femoris, semitendinosus, gluteus maximus, vastus medialis, rectus femoris and vastus lateralis. Three-dimensional high-speed video analysis was used to determine the golf swing phases. Results showed that, in average handicap golfers, the highest muscle activation levels occurred during the Forward Swing Phase, with the right semitendinosus and the right biceps femoris muscles producing the highest mean activation levels relative to maximal electromyography (70-76% and 68-73% EMG(MAX), respectively). Significant differences between the pitching wedge and the 4-iron club were found in the activation level of the left semitendinosus, right tibialis anterior, right peroneus longus, right vastus medialis, right rectus femuris and right gastrocnemius muscles. The lower limb muscles showed, in most cases and phases, higher mean values of activation on electromyography when golfers performed shots with a 4-iron club.
Lerner, Zachary F; Damiano, Diane L; Bulea, Thomas C
2016-08-01
A robotic exoskeleton was designed for individuals with crouch gait caused by cerebral palsy with the intent to supplement existing muscle function during walking. The aim of this study was to evaluate how powered knee extension assistance provided during stance and swing phases of the gait cycle affect knee kinematics, and knee flexor and extensor muscle activity. Muscle activity and kinematic data were collected from four individuals with crouch gait from cerebral palsy during their normal walking condition and while walking with the exoskeleton under stance, swing, and stance & swing assistance. The exoskeleton was effective in reducing crouch by an average of 13.8° in three of the four participants when assistance was provided during the stance phase; assistance during the swing phase alone was ineffective. Peak knee extensor activity was maintained for all of the conditions during the stance and swing phases. Integrated (i.e. area under the curve) knee extensor activity decreased in two of the subjects indicating a more well-modulated activation pattern. Modest increases in peak and integrated antagonist knee flexor activity were exhibited in all participants; the subject without kinematic improvement had the greatest increase. While the exoskeleton was well tolerated, additional training with a focus on reducing knee flexor activity may lead to further improvements in crouch gait reduction.
Research on the measurement technology of effective arm length of swing arm profilometer
NASA Astrophysics Data System (ADS)
Chen, Lin; Jing, Hongwei; Wei, Zhongwei; Li, Jie; Cao, Xuedong
2014-09-01
When the swing arm profilometer(SAP) measuring the mirror, the effective arm length of SAP which haves an obvious influence on the measurement results of the mirror surface shape needs to be measured accurately. It requires the measurement uncertainty of the effective arm length to reach 10μm in order to meet the measurement requirements, in this paper, we present a kind of technology based on laser tracker to measure the effective arm length of SAP. When the swing arm rotates around the shaft axis of swing arm rotary stage, the probe and two laser tracker balls form three sections of circular arc around the shaft axis of swing arm rotary stage in space. Laser tracker tracks and measures the circular arcs of two laser tracker balls, the center coordinates of the circular plane of circular arc can be calculated by data processing. The linear equation that passes through the two center coordinates is the equation of the shaft axis of rotary stage, the vertical distance from the probe to the shaft axis of rotary stage which can be calculated refer to the equation from the point to the line is the effective arm length. After Matlab simulation, this measurement method can meet the measurement accuracy.
Modification of hemiplegic compensatory gait pattern by symmetry-based motion controller of HAL.
Kawamoto, Hiroaki; Kadone, Hideki; Sakurai, Takeru; Sankai, Yoshiyuki
2015-01-01
As one of several characteristics of hemiplegic patients after stroke, compensatory gait caused by affected limb is often seen. The purpose of this research is to apply a symmetry-based controller of a wearable type lower limb robot, Hybrid Assistive Limb (HAL) to hemiplegic patients with compensatory gait, and to investigate improvement of gait symmetry. The controller is designed respectively for swing phase and support phase according to characteristics of hemiplegic gait pattern. The controller during swing phase stores the motion of the unaffected limb and then provides motion support on the affected limb during the subsequent swing using the stored pattern to realize symmetric gait based on spontaneous limb swing. Moreover, the controller during support phase provides motion to extend hip and knee joints to support wearer's body. Clinical tests were conducted in order to assess the modification of gait symmetry. Our case study involved participation of one chronic stroke patient who performs abnormally-compensatory gait for both of the affected and unaffected limbs. As a result, the patient's gait symmetry was improved by providing motion support during the swing phase on the affected side and motion constraint during the support phase on the unaffected side. The study showed promising basis for the effectiveness of the controller for the future clinical study.
Bae, Tae Soo; Cho, Woong; Kim, Kwon Hee; Chae, Soo Won
2014-11-01
Although the lumbar spine region is the most common site of injury in golfers, little research has been done on intervertebral loads in relation to the anatomical-morphological differences in the region. This study aimed to examine the biomechanical effects of anatomical-morphological differences in the lumbar lordosis on the lumbar spinal joints during a golf swing. The golf swing motions of ten professional golfers were analyzed. Using a subject-specific 3D musculoskeletal system model, inverse dynamic analyses were performed to compare the intervertebral load, the load on the lumbar spine, and the load in each swing phase. In the intervertebral load, the value was the highest at the L5-S1 and gradually decreased toward the T12. In each lumbar spine model, the load value was the greatest on the kypholordosis (KPL) followed by normal lordosis (NRL), hypolordosis (HPL), and excessive lordosis (EXL) before the impact phase. However, results after the follow-through (FT) phase were shown in reverse order. Finally, the load in each swing phase was greatest during the FT phase in all the lumbar spine models. The findings can be utilized in the training and rehabilitation of golfers to help reduce the risk of injury by considering individual anatomical-morphological characteristics.
NASA Astrophysics Data System (ADS)
Gu, Yongxian
The demand of portable power generation systems for both domestic and military applications has driven the advances of mesoscale internal combustion engine systems. This dissertation was devoted to the gasdynamic modeling and parametric study of the mesoscale internal combustion swing engine/generator systems. First, the system-level thermodynamic modeling for the swing engine/generator systems has been developed. The system performance as well as the potentials of both two- and four-stroke swing engine systems has been investigated based on this model. Then through parameterc studies, the parameters that have significant impacts on the system performance have been identified, among which, the burn time and spark advance time are the critical factors related to combustion process. It is found that the shorter burn time leads to higher system efficiency and power output and the optimal spark advance time is about half of the burn time. Secondly, the turbulent combustion modeling based on levelset method (G-equation) has been implemented into the commercial software FLUENT. Thereafter, the turbulent flame propagation in a generic mesoscale combustion chamber and realistic swing engine chambers has been studied. It is found that, in mesoscale combustion engines, the burn time is dominated by the mean turbulent kinetic energy in the chamber. It is also shown that in a generic mesoscale combustion chamber, the burn time depends on the longest distance between the initial ignition kernel to its walls and by changing the ignition and injection locations, the burn time can be reduced by a factor of two. Furthermore, the studies of turbulent flame propagation in real swing engine chambers show that the combustion can be enhanced through in-chamber turbulence augmentation and with higher engine frequency, the burn time is shorter, which indicates that the in-chamber turbulence can be induced by the motion of moving components as well as the intake gas jet flow. The burn time for current two-stroke swing engine is estimated as about 2.5 ms, which can be used in the prescribed burned mass fraction profile that follows the Wiebe's function. Finally, a 2D CFD code for compressible flow has been developed to study wave interactions in the engine and header system. It is found that with realistic working conditions, for a two-stroke swing engine, certain expansion waves can be created by the exhaust gas flows and the chamber pressure can reach as low as 5 psi below one atmosphere, which helps fill fresh reactant charge. The results also show that to obtain appropriate header tuning for the current two-stroke swing engine, the length of the header neck is about 40 cm.
NASA Astrophysics Data System (ADS)
Pytlak, E.; McManamon, A.; Hughes, S. P.; Van Der Zweep, R. A.; Butcher, P.; Karafotias, C.; Beckers, J.; Welles, E.
2016-12-01
Numerous studies have documented the impacts that large scale weather patterns and climate phenomenon like the El Niño Southern Oscillation (ENSO), Pacific-North American (PNA) Pattern, and others can have on seasonal temperature and precipitation in the Columbia River Basin (CRB). While far from perfect in terms of seasonal predictability in specific locations, these intra-annual weather and climate signal do tilt the odds toward different temperature and precipitation outcomes, which in turn can have impacts on seasonal snowpacks, streamflows and water supply in large river basins like the CRB. We hypothesize that intraseasonal climate signals and long wave jet stream patterns can be objectively incorporated into what it is otherwise a climatology-based set of Ensemble Streamflow Forecasts, and can increase the predictive skill and utility of these forecasts used for mid-range hydropower planning. The Bonneville Power Administration (BPA) and Deltares have developed a subsampling-resampling method to incorporate climate mode information into the Ensemble Streamflow Prediction (ESP) forecasts (Beckers, et al., 2016). Since 2015, BPA and Deltares USA have experimented with this method in pre-operational use, using five objective multivariate climate indices that appear to have the greatest predictive value for seasonal temperature and precipitation in the CRB. The indices are used to objectively select historical weather from about twenty analog years in the 66-year (1949-2015) historical ESP set. These twenty scenarios then serve as the starting point to generate monthly synthetic weather and streamflow time series to return to a set of 66 streamflow traces. Our poster will share initial results from the 2015 and 2016 water years, which included large swings in the Quasi-Biennial Oscillation, persistent blocking jet stream patterns, and the development of a strong El Niño event. While the results are very preliminary and for only two seasons, there may be some value in incorporating objectively-identified climate signals into ESP-based streamflow forecasts.Beckers, J. V. L., Weerts, A. H., Tijdeman, E., and Welles, E.: ENSO-Conditioned Weather Resampling Method for Seasonal Ensemble Streamflow Prediction, Hydrol. Earth Syst. Sci. Discuss., doi:10.5194/hess-2016-72, in review, 2016.
Control of electrothermal heating during regeneration of activated carbon fiber cloth.
Johnsen, David L; Mallouk, Kaitlin E; Rood, Mark J
2011-01-15
Electrothermal swing adsorption (ESA) of organic gases generated by industrial processes can reduce atmospheric emissions and allow for reuse of recovered product. Desorption energy efficiency can be improved through control of adsorbent heating, allowing for cost-effective separation and concentration of these gases for reuse. ESA experiments with an air stream containing 2000 ppm(v) isobutane and activated carbon fiber cloth (ACFC) were performed to evaluate regeneration energy consumption. Control logic based on temperature feedback achieved select temperature and power profiles during regeneration cycles while maintaining the ACFC's mean regeneration temperature (200 °C). Energy requirements for regeneration were independent of differences in temperature/power oscillations (1186-1237 kJ/mol of isobutane). ACFC was also heated to a ramped set-point, and the average absolute error between the actual and set-point temperatures was small (0.73%), demonstrating stable control as set-point temperatures vary, which is necessary for practical applications (e.g., higher temperatures for higher boiling point gases). Additional logic that increased the maximum power application at lower ACFC temperatures resulted in a 36% decrease in energy consumption. Implementing such control logic improves energy efficiency for separating and concentrating organic gases for post-desorption liquefaction of the organic gas for reuse.
2007-01-26
ocean affects calcifying organisms, such as corals , with significant effects to reefs , the ecosystems they support, and their ability to pro- tect...water coral reefs , to open- ocean systems. For example, increasing ocean acidity, altered biogeochemistry, changing current patterns, loss of sea ice...for example, large swings in the populations of commercial fisheries, changes in seabird-population distributions, and coral - reef -bleaching events
Single InAs/GaSb nanowire low-power CMOS inverter.
Dey, Anil W; Svensson, Johannes; Borg, B Mattias; Ek, Martin; Wernersson, Lars-Erik
2012-11-14
III-V semiconductors have so far predominately been employed for n-type transistors in high-frequency applications. This development is based on the advantageous transport properties and the large variety of heterostructure combinations in the family of III-V semiconductors. In contrast, reports on p-type devices with high hole mobility suitable for complementary metal-oxide-semiconductor (CMOS) circuits for low-power operation are scarce. In addition, the difficulty to integrate both n- and p-type devices on the same substrate without the use of complex buffer layers has hampered the development of III-V based digital logic. Here, inverters fabricated from single n-InAs/p-GaSb heterostructure nanowires are demonstrated in a simple processing scheme. Using undoped segments and aggressively scaled high-κ dielectric, enhancement mode operation suitable for digital logic is obtained for both types of transistors. State-of-the-art on- and off-state characteristics are obtained and the individual long-channel n- and p-type transistors exhibit minimum subthreshold swings of SS = 98 mV/dec and SS = 400 mV/dec, respectively, at V(ds) = 0.5 V. Inverter characteristics display a full signal swing and maximum gain of 10.5 with a small device-to-device variability. Complete inversion is measured at low frequencies although large parasitic capacitances deform the waveform at higher frequencies.
High electron mobility and quantum oscillations in non-encapsulated ultrathin semiconducting Bi2O2Se
NASA Astrophysics Data System (ADS)
Wu, Jinxiong; Yuan, Hongtao; Meng, Mengmeng; Chen, Cheng; Sun, Yan; Chen, Zhuoyu; Dang, Wenhui; Tan, Congwei; Liu, Yujing; Yin, Jianbo; Zhou, Yubing; Huang, Shaoyun; Xu, H. Q.; Cui, Yi; Hwang, Harold Y.; Liu, Zhongfan; Chen, Yulin; Yan, Binghai; Peng, Hailin
2017-07-01
High-mobility semiconducting ultrathin films form the basis of modern electronics, and may lead to the scalable fabrication of highly performing devices. Because the ultrathin limit cannot be reached for traditional semiconductors, identifying new two-dimensional materials with both high carrier mobility and a large electronic bandgap is a pivotal goal of fundamental research. However, air-stable ultrathin semiconducting materials with superior performances remain elusive at present. Here, we report ultrathin films of non-encapsulated layered Bi2O2Se, grown by chemical vapour deposition, which demonstrate excellent air stability and high-mobility semiconducting behaviour. We observe bandgap values of ˜0.8 eV, which are strongly dependent on the film thickness due to quantum-confinement effects. An ultrahigh Hall mobility value of >20,000 cm2 V-1 s-1 is measured in as-grown Bi2O2Se nanoflakes at low temperatures. This value is comparable to what is observed in graphene grown by chemical vapour deposition and at the LaAlO3-SrTiO3 interface, making the detection of Shubnikov-de Haas quantum oscillations possible. Top-gated field-effect transistors based on Bi2O2Se crystals down to the bilayer limit exhibit high Hall mobility values (up to 450 cm2 V-1 s-1), large current on/off ratios (>106) and near-ideal subthreshold swing values (˜65 mV dec-1) at room temperature. Our results make Bi2O2Se a promising candidate for future high-speed and low-power electronic applications.
29 CFR Appendix E to Subpart M of... - Sample Fall Protection Plan
Code of Federal Regulations, 2014 CFR
2014-07-01
... edge of the floor or beam and swing the worker like a pendulum until the line has moved to a position... points. Accompanying this pendulum swing is a lowering of the worker, with the attendant danger that he...
Photometric Observations of Main-belt Asteroids 1637 Swings 10498 Bobgent, and (25980) 2001 FK53
NASA Astrophysics Data System (ADS)
Brincat, Stephen M.; Galdies, Charles
2018-04-01
Photometric observations of asteroids 1637 Swings, 10498 Bobgent and (25980) 2001 FK 53 were acquired from Flarestar Observatory (MPC171) and Znith Observatory in 2017. The observations were made during a favourable apparition for each asteroid.
17. CONTROL ROOM, NORTH SIDE, WITH BRIDGE SWING CONTROLS ON ...
17. CONTROL ROOM, NORTH SIDE, WITH BRIDGE SWING CONTROLS ON LEFT, SIGNAL CONTROLS ON RIGHT, WHISTLE PULL TOP. RADIO TELEPHONE IN CENTER BACK (Fred Small) - Burlington Northern Railroad Bridge, Spanning Willamette River at River Mile 6.9, Portland, Multnomah County, OR
Study on safety operation for large hydroelectric generator unit
NASA Astrophysics Data System (ADS)
Yan, Z. G.; Cui, T.; Zhou, L. J.; Zhi, F. L.; Wang, Z. W.
2012-11-01
Hydroelectric generator unit is a complex mechanical system which is composed of hydraulic turbine and electric generator. Rotary system is supported by the bearing bracket and the reinforced concrete structures, and vibration problem can't be avoided in the process of operating. Many large-scale hydroelectric units have been damaged because of the vibration problem in recent years. As the increase of the hydraulic turbine unit capacity and water head, the safe operation of hydraulic turbine has become a focus research in many countries. The operating characteristics of the hydraulic turbine have obvious differences at different working conditions. Based on the combination of field measurement and theoretical calculation, this paper shows a deep research on the safe operation of a large-scale Francis turbine unit. Firstly, the measurements of vibration, swing, pressure fluctuation and noise were carried out at 4 different heads. And also the relationships between vibrations and pressure fluctuations at different heads and working conditions were analysed deeply. Then the scientific prediction of safe operation for the unit at high head were done based on the CFD numerical calculation. Finally, this paper shows the division of the operating zone for the hydroelectric unit. According to the experimental results (vibrations, swings, pressure fluctuations and noise) as well as the theoretical results, the operating zone of the unit has been divided into three sections: prohibited operating zone, transition operating zone and safe operating zone. After this research was applied in the hydropower station, the security and economic efficiency of unit increased greatly, and enormous economic benefits and social benefits have been obtained.
NASA Astrophysics Data System (ADS)
Tsai, Jung-Hui; Chen, Jeng-Shyan; Chu, Yu-Jui
2005-01-01
The influence of δ-doping channels on the performance of n +-GaAs/p +-InGaP/n-GaAs camel-gate field effect transistors is investigated by theoretical analysis and experimental results. The depleted pn junction of the camel gate and the existence of considerable conduction band discontinuity at the InGaP/GaAs heterojunction enhance the potential barrier height and the forward gate voltage. As the concentration-thickness products of the n-GaAs layer and δ-doping layer are fixed, the higher δ-doping device exhibits a higher potential barrier height, a larger drain current, and a broader gate voltage swing, whereas the transconductance is somewhat lower. For a n +=5.5×10 12 cm -2δ-doping device, the experimental result exhibits a maximum transconductance of 240 mS/mm and a gate voltage swing of 3.5 V. Consequently, the studied devices provide a good potential for large signal and linear circuit applications.
Suitability of Strain Gage Sensors for Integration into Smart Sport Equipment: A Golf Club Example.
Umek, Anton; Zhang, Yuan; Tomažič, Sašo; Kos, Anton
2017-04-21
Wearable devices and smart sport equipment are being increasingly used in amateur and professional sports. Smart sport equipment employs various sensors for detecting its state and actions. The correct choice of the most appropriate sensor(s) is of paramount importance for efficient and successful operation of sport equipment. When integrated into the sport equipment, ideal sensors are unobstructive, and do not change the functionality of the equipment. The article focuses on experiments for identification and selection of sensors that are suitable for the integration into a golf club with the final goal of their use in real time biofeedback applications. We tested two orthogonally affixed strain gage (SG) sensors, a 3-axis accelerometer, and a 3-axis gyroscope. The strain gage sensors are calibrated and validated in the laboratory environment by a highly accurate Qualisys Track Manager (QTM) optical tracking system. Field test results show that different types of golf swing and improper movement in early phases of golf swing can be detected with strain gage sensors attached to the shaft of the golf club. Thus they are suitable for biofeedback applications to help golfers to learn repetitive golf swings. It is suggested that the use of strain gage sensors can improve the golf swing technical error detection accuracy and that strain gage sensors alone are enough for basic golf swing analysis. Our final goal is to be able to acquire and analyze as many parameters of a smart golf club in real time during the entire duration of the swing. This would give us the ability to design mobile and cloud biofeedback applications with terminal or concurrent feedback that will enable us to speed-up motor skill learning in golf.
Suitability of Strain Gage Sensors for Integration into Smart Sport Equipment: A Golf Club Example
Umek, Anton; Zhang, Yuan; Tomažič, Sašo; Kos, Anton
2017-01-01
Wearable devices and smart sport equipment are being increasingly used in amateur and professional sports. Smart sport equipment employs various sensors for detecting its state and actions. The correct choice of the most appropriate sensor(s) is of paramount importance for efficient and successful operation of sport equipment. When integrated into the sport equipment, ideal sensors are unobstructive, and do not change the functionality of the equipment. The article focuses on experiments for identification and selection of sensors that are suitable for the integration into a golf club with the final goal of their use in real time biofeedback applications. We tested two orthogonally affixed strain gage (SG) sensors, a 3-axis accelerometer, and a 3-axis gyroscope. The strain gage sensors are calibrated and validated in the laboratory environment by a highly accurate Qualisys Track Manager (QTM) optical tracking system. Field test results show that different types of golf swing and improper movement in early phases of golf swing can be detected with strain gage sensors attached to the shaft of the golf club. Thus they are suitable for biofeedback applications to help golfers to learn repetitive golf swings. It is suggested that the use of strain gage sensors can improve the golf swing technical error detection accuracy and that strain gage sensors alone are enough for basic golf swing analysis. Our final goal is to be able to acquire and analyze as many parameters of a smart golf club in real time during the entire duration of the swing. This would give us the ability to design mobile and cloud biofeedback applications with terminal or concurrent feedback that will enable us to speed-up motor skill learning in golf. PMID:28430147
Prilutsky, B I; Gregor, R J
2001-07-01
There has been no consistent explanation as to why humans prefer changing their gait from walking to running and from running to walking at increasing and decreasing speeds, respectively. This study examined muscle activation as a possible determinant of these gait transitions. Seven subjects walked and ran on a motor-driven treadmill for 40s at speeds of 55, 70, 85, 100, 115, 130 and 145% of the preferred transition speed. The movements of subjects were videotaped, and surface electromyographic activity was recorded from seven major leg muscles. Resultant moments at the leg joints during the swing phase were calculated. During the swing phase of locomotion at preferred running speeds (115, 130, 145%), swing-related activation of the ankle, knee and hip flexors and peaks of flexion moments were typically lower (P<0.05) during running than during walking. At preferred walking speeds (55, 70, 85%), support-related activation of the ankle and knee extensors was typically lower during stance of walking than during stance of running (P<0.05). These results support the hypothesis that the preferred walk-run transition might be triggered by the increased sense of effort due to the exaggerated swing-related activation of the tibialis anterior, rectus femoris and hamstrings; this increased activation is necessary to meet the higher joint moment demands to move the swing leg during fast walking. The preferred run-walk transition might be similarly triggered by the sense of effort due to the higher support-related activation of the soleus, gastrocnemius and vastii that must generate higher forces during slow running than during walking at the same speed.
[Polish adaptation of swing questionnaire (Survey Work-home Interaction - Nijmegen)].
Mościcka-Teske, Agnieszka; Merecz, Dorota
2012-01-01
The aim of the paper is to present the Polish adaptation of Survey Work-Home Interaction - Nijmegen (SWING). The analyses were based on the survey results from two groups of subjects, a sample of workers, representative in terms of sex and age, living in urban areas (N = 600) and a group of 59 employees examined twice with a help of SWING to assess the stability of the obtained results over a month time. The analyses performed proved that the Polish version of SWING is a reliable tool for studying work-home interactions. Correlation coefficients of items with total result of negative work-home interaction (WHI) subscale varied from 0.51 to 0.74, with positive WHI subscale from 0.26 to 0.60, negative home-work interaction (HWI) subscale, from 0.54 to 0.68 and positive HWI subscale from 0.31 to 0.59. Cronbach's alpha for the whole survey was 0.79, and for subscales varied from 0.73 to 0.89. The results of factorial analysis confirmed a our-factor structure of SWING. Factors I, items had loading from 0.58 to 0.81; II, from 0.29 to 0.78; III, from 0.60 to 0.80; and IV, from 0.28 to 0.74. The values of fit index for a four-factor model, were 0.91 (NNFI), 0.06 (RMSEA), and 0.92 (CFI), which means that this model is characterized by a good fit to empirical data. The correlation coefficient between two measurements at one month interval were also high and reached the range of 0.63 to 0.84. The results obtained are comparable to the psychometric characteristic of the English version of SWING.
NASA Astrophysics Data System (ADS)
Sun, Jia; Wan, Qing; Lu, Aixia; Jiang, Jie
2009-11-01
Battery drivable low-voltage SnO2-based paper thin-film transistors with a near-zero threshold voltage (Vth=0.06 V) gated by microporous SiO2 dielectric with electric-double-layer (EDL) effect are fabricated at room temperature. The operating voltage is found to be as low as 1.5 V due to the huge gate specific capacitance (1.34 μF/cm2 at 40 Hz) related to EDL formation. The subthreshold gate voltage swing and current on/off ratio is found to be 82 mV/decade and 2.0×105, respectively. The electron field-effect mobility is estimated to be 47.3 cm2/V s based on the measured gate specific capacitance at 40 Hz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahn, Byung Du; Park, Jin-Seong; Chung, K. B., E-mail: kbchung@dongguk.edu
Device performance of InGaZnO (IGZO) thin film transistors (TFTs) are investigated as a function of hydrogen ion irradiation dose at room temperature. Field effect mobility is enhanced, and subthreshold gate swing is improved with the increase of hydrogen ion irradiation dose, and there is no thermal annealing. The electrical device performance is correlated with the electronic structure of IGZO films, such as chemical bonding states, features of the conduction band, and band edge states below the conduction band. The decrease of oxygen deficient bonding and the changes in electronic structure of the conduction band leads to the improvement of devicemore » performance in IGZO TFT with an increase of the hydrogen ion irradiation dose.« less
Carbon dioxide adsorbents containing magnesium oxide suitable for use at high temperatures
Mayorga, Steven Gerard; Weigel, Scott Jeffrey; Gaffney, Thomas Richard; Brzozowski, Jeffrey Richard
2001-01-01
Adsorption of carbon dioxide from gas streams at temperatures in the range of 300 to 500.degree. C. is carried out with a solid adsorbent containing magnesium oxide, preferably promoted with an alkali metal carbonate or bicarbonate so that the atomic ratio of alkali metal to magnesium is in the range of 0.006 to 2.60. Preferred adsorbents are made from the precipitate formed on addition of alkali metal and carbonate ions to an aqueous solution of a magnesium salt. Atomic ratios of alkali metal to magnesium can be adjusted by washing the precipitate with water. Low surface area adsorbents can be made by dehydration and CO.sub.2 removal of magnesium hydroxycarbonate, with or without alkali metal promotion. The process is especially valuable in pressure swing adsorption operations.
Bi-layer Channel AZO/ZnO Thin Film Transistors Fabricated by Atomic Layer Deposition Technique
NASA Astrophysics Data System (ADS)
Li, Huijin; Han, Dedong; Liu, Liqiao; Dong, Junchen; Cui, Guodong; Zhang, Shengdong; Zhang, Xing; Wang, Yi
2017-03-01
This letter demonstrates bi-layer channel Al-doped ZnO/ZnO thin film transistors (AZO/ZnO TFTs) via atomic layer deposition process at a relatively low temperature. The effects of annealing in oxygen atmosphere at different temperatures have also been investigated. The ALD bi-layer channel AZO/ZnO TFTs annealed in dry O2 at 300 °C exhibit a low leakage current of 2.5 × 10-13A, I on/ I off ratio of 1.4 × 107, subthreshold swing (SS) of 0.23 V/decade, and high transmittance. The enhanced performance obtained from the bi-layer channel AZO/ZnO TFT devices is explained by the inserted AZO front channel layer playing the role of the mobility booster.
Climate Science: Tropical Expansion by Ocean Swing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Jian
The tropical belt has become wider over the past decades, but climate models fall short of capturing the full rate of the expansion. The latest analysis of the climate simulations suggests that a long-term swing of the Pacific Decadal Oscillation is the main missing cause.
20. VIEW TO SOUTHEAST AT CENTERLINE (U37) WHERE SWING SPANS ...
20. VIEW TO SOUTHEAST AT CENTERLINE (U37) WHERE SWING SPANS MEET. PIVOT PIER 1N AT LEFT, PIVOT PIER 1S AT RIGHT. - George P. Coleman Memorial Bridge, Spanning York River at U.S. Route 17, Yorktown, York County, VA
Unbounded orbits of a swinging Atwood's machine
NASA Astrophysics Data System (ADS)
Tufillaro, N.; Nunes, A.; Casasayas, J.
1988-12-01
The motion of a swinging Atwood's machine is examined when the orbits are unbounded. Expressions for the asymptotic behavior of the orbits are derived that exhibit either an infinite number of oscillations or no oscillations, depending only on a critical value of the mass ratio.
Teardrop and heart orbits of a swinging Atwood's machine
NASA Astrophysics Data System (ADS)
Tufillaro, Nicholas B.
1994-03-01
An exact solution is presented for a swinging Atwood's machine. This teardrop-heart orbit is constructed using Hamilton-Jacobi theory. The example nicely illustrates the utility of the Hamilton-Jacobi method for finding solutions to nonlinear mechanical systems when more elementary techniques fail.
“Gunslinger’s gait”: a new cause of unilaterally reduced arm swing
Araújo, Rui; Ferreira, Joaquim J; Antonini, Angelo
2015-01-01
Objective To postulate a new possible cause of a unilaterally reduced arm swing in addition to the known medical conditions such as shoulder pathology, Erb’s palsy, stroke, and Parkinson’s disease. Methods Analysis of YouTube videos depicting the gait of highly ranked Russian officials. Results We found a similar walking pattern in President Vladimir Putin, Prime Minister Dmitry Medvedev and three other highly ranked Russian officials, all presenting with a consistently reduced right arm swing in the absence of other overt neurological abnormalities. Conclusions We propose that this new gait pattern, which we term “gunslinger’s gait,” may result from a behavioural adaptation, possibly triggered by KGB or other forms of weapons training where trainees are taught to keep their right hand close to the chest while walking, allowing them to quickly draw a gun when faced with a foe. This should be included in the differential diagnosis of a unilaterally reduced arm swing. PMID:26666758
Myosin V is a biological Brownian machine.
Fujita, Keisuke; Iwaki, Mitsuhiro
2014-01-01
Myosin V is a vesicle transporter that unidirectionally walks along cytoskeletal actin filaments by converting the chemical energy of ATP into mechanical work. Recently, it was found that myosin V force generation is a composition of two processes: a lever-arm swing, which involves a conformational change in the myosin molecule, and a Brownian search-and-catch, which involves a diffusive "search" by the motor domain that is followed by an asymmetric "catch" in the forward actin target such that Brownian motion is rectified. Here we developed a system that combines optical tweezers with DNA nano-material to show that the Brownian search-and-catch mechanism is the energetically dominant process at near stall force, providing 13 kBT of work compared to just 3 kBT by the lever-arm swing. Our result significantly reconsiders the lever-arm swinging model, which assumes the swing dominantly produces work (>10 kBT), and sheds light on the Brownian search-and-catch as a driving process.
Hayes, Heather Brant; Chang, Young-Hui
2012-01-01
Presynaptic inhibition is a powerful mechanism for selectively and dynamically gating sensory inputs entering the spinal cord. We investigated how hindlimb mechanics influence presynaptic inhibition during locomotion using pioneering approaches in an in vitro spinal cord–hindlimb preparation. We recorded lumbar dorsal root potentials to measure primary afferent depolarization-mediated presynaptic inhibition and compared their dependence on hindlimb endpoint forces, motor output, and joint kinematics. We found that stance-phase force on the opposite limb, particularly at toe contact, strongly influenced the magnitude and timing of afferent presynaptic inhibition in the swinging limb. Presynaptic inhibition increased in proportion to opposite limb force, as well as locomotor frequency. This form of presynaptic inhibition binds the sensorimotor states of the two limbs, adjusting sensory inflow to the swing limb based on forces generated by the stance limb. Functionally, it may serve to adjust swing-phase sensory transmission based on locomotor task, speed, and step-to-step environmental perturbations. PMID:22442562
Myosin V is a biological Brownian machine
Fujita, Keisuke; Iwaki, Mitsuhiro
2014-01-01
Myosin V is a vesicle transporter that unidirectionally walks along cytoskeletal actin filaments by converting the chemical energy of ATP into mechanical work. Recently, it was found that myosin V force generation is a composition of two processes: a lever-arm swing, which involves a conformational change in the myosin molecule, and a Brownian search-and-catch, which involves a diffusive “search” by the motor domain that is followed by an asymmetric “catch” in the forward actin target such that Brownian motion is rectified. Here we developed a system that combines optical tweezers with DNA nano-material to show that the Brownian search-and-catch mechanism is the energetically dominant process at near stall force, providing 13 kBT of work compared to just 3 kBT by the lever-arm swing. Our result significantly reconsiders the lever-arm swinging model, which assumes the swing dominantly produces work (>10 kBT), and sheds light on the Brownian search-and-catch as a driving process. PMID:27493501
The use of 3D scanning for sporting applications
NASA Astrophysics Data System (ADS)
Friel, Kevin; Ajjimaporn, Pann; Straub, Jeremy; Kerlin, Scott
2015-05-01
This paper describes the process and research that went into creating a set of 3D models to characterize a golf swing. The purpose of this work is to illustrate how a 3D scanner could be used for assessing athlete performance in sporting applications. In this case, introductory work has been performed to show how the scanner could be used to show the errors a golfer made in a swing. Multiple factors must be taken into account when assessing golfers' swings including the position and movement of the golfer's hands, arms, and foot placement as well as the position of the club head and shaft of the golf club.
Ruggles, C.A.
1957-08-27
A swinging arm gage designed to measure radial angles, tapering, sloping, or arcuate concave surfaces is described. The principle of the swinging arm gage is that in any spherical system, radii and radial lines established by them pass through the center of the sphere. Thus if an arm be made to pivot at the sphere center, the path of the swinging end can be guided by a can so set as to establish the proper center angle, and dial indicators on the arm can be zeroed on a master object, angular and dimensional manufacturing errors can be determined on a duplicate object. This device makes possible a considerable saving of time in measuring complex arcuate contours.
A Standalone Vision Impairments Simulator for Java Swing Applications
NASA Astrophysics Data System (ADS)
Oikonomou, Theofanis; Votis, Konstantinos; Korn, Peter; Tzovaras, Dimitrios; Likothanasis, Spriridon
A lot of work has been done lately in an attempt to assess accessibility. For the case of web rich-client applications several tools exist that simulate how a vision impaired or colour-blind person would perceive this content. In this work we propose a simulation tool for non-web JavaTM Swing applications. Developers and designers face a real challenge when creating software that has to cope with a lot of interaction situations, as well as specific directives for ensuring an accessible interaction. The proposed standalone tool will assist them to explore user-centered design and important accessibility issues for their JavaTM Swing implementations.
Novel Field-Effect Schottky Barrier Transistors Based on Graphene-MoS2 Heterojunctions
Tian, He; Tan, Zhen; Wu, Can; Wang, Xiaomu; Mohammad, Mohammad Ali; Xie, Dan; Yang, Yi; Wang, Jing; Li, Lain-Jong; Xu, Jun; Ren, Tian-Ling
2014-01-01
Recently, two-dimensional materials such as molybdenum disulphide (MoS2) have been demonstrated to realize field effect transistors (FET) with a large current on-off ratio. However, the carrier mobility in backgate MoS2 FET is rather low (typically 0.5–20 cm2/V·s). Here, we report a novel field-effect Schottky barrier transistors (FESBT) based on graphene-MoS2 heterojunction (GMH), where the characteristics of high mobility from graphene and high on-off ratio from MoS2 are properly balanced in the novel transistors. Large modulation on the device current (on/off ratio of 105) is achieved by adjusting the backgate (through 300 nm SiO2) voltage to modulate the graphene-MoS2 Schottky barrier. Moreover, the field effective mobility of the FESBT is up to 58.7 cm2/V·s. Our theoretical analysis shows that if the thickness of oxide is further reduced, a subthreshold swing (SS) of 40 mV/decade can be maintained within three orders of drain current at room temperature. This provides an opportunity to overcome the limitation of 60 mV/decade for conventional CMOS devices. The FESBT implemented with a high on-off ratio, a relatively high mobility and a low subthreshold promises low-voltage and low-power applications for future electronics. PMID:25109609
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-08
... manufactured wafer swing check valves. The wafer swing check valves will be used for the filter feed pumps as... check valves will prevent backflow into the filter feed pumps at the Glen Water Reclamation Facility in...
Dynamic Hip Kinematics During the Golf Swing After Total Hip Arthroplasty.
Hara, Daisuke; Nakashima, Yasuharu; Hamai, Satoshi; Higaki, Hidehiko; Ikebe, Satoru; Shimoto, Takeshi; Yoshimoto, Kensei; Iwamoto, Yukihide
2016-07-01
Although most surgeons allow their patients to play golf after total hip arthroplasty (THA), the effect on the implant during the golf swing is still unclear. To evaluate hip kinematics during the golf swing after THA. Descriptive laboratory study. Eleven hips in 9 patients who underwent primary THA were analyzed. All patients were right-handed recreational golfers, and these 11 hips included 6 right hips and 5 left hips. Periodic radiographic images of the golf swing were taken using a flat-panel x-ray detector. Movements of the hip joint and components were assessed using 3-dimensional-to-2-dimensional model-to-image registration techniques. Liner-to-neck contact and translation of the femoral head with respect to the acetabular cup (cup-head translation) were examined. Hip kinematics, orientation of components, and maximum cup-head translation were compared between patients with and without liner-to-neck contact. On average, the golf swing produced approximately 50° of axial rotation in both lead and trail hips. Liner-to-neck contact was observed in 4 hips with elevated rim liners (2 lead hips and 2 trail hips) at maximum external rotation. Neither bone-to-bone nor bone-to-implant contact was observed at any phases of the golf swing in any of the hips. Four hips with liner-to-neck contact had significantly larger maximum external rotation (37.9° ± 7.0° vs 20.6° ± 9.9°, respectively; P = .01) and more cup anteversion (26.5° ± 6.1° vs 10.8° ± 8.9°, respectively; P = .01) than hips without liner-to-neck contact. No significant differences between hips with and without contact were found for cup inclination (42.0° ± 2.5° vs 38.1° ± 5.5°, respectively; P = .22), combined anteversion (45.3° ± 8.9° vs 51.4° ± 7.9°, respectively; P = .26), or maximum cup-head translation (1.3 ± 0.3 mm vs 1.5 ± 0.4 mm, respectively; P = .61). In this analysis, the golf swing did not produce excessive hip rotation or cup-head translation in any hips. However, liner-to-neck contact during the golf swing was observed in 36% of the hips, with unknown effects on the long-term results. Golf is an admissible sport after THA because dynamic hip stability was observed. However, the implant position, especially cup anteversion and the use of elevated rim liners, promoted liner-to-neck contact. © 2016 The Author(s).
NASA Astrophysics Data System (ADS)
Ramli, Liyana; Mohamed, Z.; Jaafar, H. I.
2018-07-01
This paper proposes an improved input shaping for minimising payload swing of an overhead crane with payload hoisting and payload mass variations. A real time unity magnitude zero vibration (UMZV) shaper is designed by using an artificial neural network trained by particle swarm optimisation. The proposed technique could predict and directly update the shaper's parameters in real time to handle the effects of time-varying parameters during the crane operation with hoisting. To evaluate the performances of the proposed method, experiments are conducted on a laboratory overhead crane with a payload hoisting, different payload masses and two different crane motions. The superiority of the proposed method is confirmed by reductions of at least 38.9% and 91.3% in the overall and residual swing responses, respectively over a UMZV shaper designed using an average operating frequency and a robust shaper namely Zero Vibration Derivative-Derivative (ZVDD). The proposed method also demonstrates a significant residual swing suppression as compared to a ZVDD shaper designed based on varying frequency. In addition, the significant reductions are achieved with a less shaper duration resulting in a satisfactory speed of response. It is envisaged that the proposed method can be used for designing effective input shapers for payload swing suppression of a crane with time-varying parameters and for a crane that employ finite actuation states.
Giatsis, George; Panoutsakopoulos, Vassilios; Kollias, Iraklis A
2018-05-01
The purpose of this study was to investigate the possible arm swing effect on the biomechanical parameters of vertical counter movement jump due to differences of the compliance of the take-off surface. Fifteen elite male beach-volleyball players (26.2 ± 5.9 years; 1.87 ± 0.05 m; 83.4 ± 6.0 kg; mean ± standard deviation, respectively) performed counter movement jumps on sand and on a rigid surface with and without an arm swing. Results showed significant (p < .05) surface effects on the jump height, the ankle joint angle at the lowest height of the body center of mass and the ankle angular velocity. Also, significant arm swing effects were found on jump height, maximum power output, temporal parameters, range of motion and angular velocity of the hip. These findings could be attributed to the instability of the sand, which resulted in reduced peak power output due to the differences of body configuration at the lowest body position and lower limb joints' range of motion. The combined effect of the backward arm swing and the recoil of the sand that resulted in decreased resistance at ankle plantar flexion should be controlled at the preparation of selected jumping tasks in beach-volleyball.
The role of upper torso and pelvis rotation in driving performance during the golf swing.
Myers, Joseph; Lephart, Scott; Tsai, Yung-Shen; Sell, Timothy; Smoliga, James; Jolly, John
2008-01-15
While the role of the upper torso and pelvis in driving performance is anecdotally appreciated by golf instructors, their actual biomechanical role is unclear. The aims of this study were to describe upper torso and pelvis rotation and velocity during the golf swing and determine their role in ball velocity. One hundred recreational golfers underwent a biomechanical golf swing analysis using their own driver. Upper torso and pelvic rotation and velocity, and torso-pelvic separation and velocity, were measured for each swing. Ball velocity was assessed with a golf launch monitor. Group differences (groups based on ball velocity) and moderate relationships (r > or = 0.50; P < 0.001) were observed between an increase in ball velocity and the following variables: increased torso-pelvic separation at the top of the swing, maximum torso-pelvic separation, maximum upper torso rotation velocity, upper torso rotational velocity at lead arm parallel and last 40 ms before impact, maximum torso-pelvic separation velocity and torso-pelvic separation velocity at both lead arm parallel and at the last 40 ms before impact. Torso-pelvic separation contributes to greater upper torso rotation velocity and torso-pelvic separation velocity during the downswing, ultimately contributing to greater ball velocity. Golf instructors can consider increasing ball velocity by maximizing separation between the upper torso and pelvis at the top of and initiation of the downswing.
Yoon, Jiyeon; Park, Jinse; Park, Kunbo; Jo, Geunyeol; Kim, Haeyu; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Eung Seok; Kim, Hee-Tae; Youm, Chang Hong
2016-01-01
Recently, arm facilitation has been interested in gait rehabilitation. However, there have been few studies concerning arm facilitation in patients with Parkinson's disease (PD). The aim of our study was to investigate the effect of increasing arm weights on gait pattern in patients with PD. Twenty-seven patients with PD were enrolled, and they underwent gait analysis using a three-dimensional motion capture system. Sandbags were applied to the distal forearms in all participants. We compared gait parameters including arm swing, pelvic motion, spatiotemporal data, and relative rotational angle between the weighted and unweighted gaits. The total arm-swing amplitude and pelvic rotation were significantly higher when walking with additional arm weights than without arm weights. Cadence, walking speed, stride length, and swing phase were significantly higher, whereas stride time, double-support time, and stance phase were significantly lower, when walking with additional arm weights than without arm weights. We conclude that adding weights to the arm during walking may facilitate arm and pelvic movements, which results in changes to gait patterns. The therapeutic use of additional arm weights could be considered for gait rehabilitation in PD to improve gait impairment. Arm-swing facilitation using weight load improved gait in Parkinson's disease. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Ku, Hao-Hsiang
2015-01-01
Nowadays, people can easily use a smartphone to get wanted information and requested services. Hence, this study designs and proposes a Golf Swing Injury Detection and Evaluation open service platform with Ontology-oritened clustering case-based reasoning mechanism, which is called GoSIDE, based on Arduino and Open Service Gateway initative (OSGi). GoSIDE is a three-tier architecture, which is composed of Mobile Users, Application Servers and a Cloud-based Digital Convergence Server. A mobile user is with a smartphone and Kinect sensors to detect the user's Golf swing actions and to interact with iDTV. An application server is with Intelligent Golf Swing Posture Analysis Model (iGoSPAM) to check a user's Golf swing actions and to alter this user when he is with error actions. Cloud-based Digital Convergence Server is with Ontology-oriented Clustering Case-based Reasoning (CBR) for Quality of Experiences (OCC4QoE), which is designed to provide QoE services by QoE-based Ontology strategies, rules and events for this user. Furthermore, GoSIDE will automatically trigger OCC4QoE and deliver popular rules for a new user. Experiment results illustrate that GoSIDE can provide appropriate detections for Golfers. Finally, GoSIDE can be a reference model for researchers and engineers.
Tsukahara, Atsushi; Hasegawa, Yasuhisa; Eguchi, Kiyoshi; Sankai, Yoshiyuki
2015-03-01
This paper proposes a novel gait intention estimator for an exoskeleton-wearer who needs gait support owing to walking impairment. The gait intention estimator not only detects the intention related to the start of the swing leg based on the behavior of the center of ground reaction force (CoGRF), but also infers the swing speed depending on the walking velocity. The preliminary experiments categorized into two stages were performed on a mannequin equipped with the exoskeleton robot [Hybrid Assistive Limb: (HAL)] including the proposed estimator. The first experiment verified that the gait support system allowed the mannequin to walk properly and safely. In the second experiment, we confirmed the differences in gait characteristics attributed to the presence or absence of the proposed swing speed profile. As a feasibility study, we evaluated the walking capability of a severe spinal cord injury patient supported by the system during a 10-m walk test. The results showed that the system enabled the patient to accomplish a symmetrical walk from both spatial and temporal standpoints while adjusting the speed of the swing leg. Furthermore, the critical differences of gait between our system and a knee-ankle-foot orthosis were obtained from the CoGRF distribution and the walking time. Through the tests, we demonstrated the effectiveness and practical feasibility of the gait support algorithms.
Progress Toward a Compact 0.05 K Magnet Refrigerator Operating from 10 K
NASA Technical Reports Server (NTRS)
Canavan, Edgar; Shirron, Peter; DiPirro, Micheal; Tuttle, James; Jackson, Michael; King, Todd; Numazawa, Takenori
2003-01-01
Much of the most interesting information regarding our universe is hidden in the sub-millimeter, infrared, and x-rays bands of the spectrum, to which our atmosphere is largely opaque. Thus, missions exploring these bands are a very important part of NASA s Space Science program. Coincidentally, the most sensitive detectors in these spectral regions operate at extremely low temperatures, typically 0.05 - 0.10 K. Generally these temperatures will be achieved using magnetic refrigerators, also know as Adiabatic Demagnetization Refrigerators, or ADRs. Current ADRs, such as the one used in the XRS-II instrument on the Astro-E2 satellite, use a single-stage to cool detectors from 1.3 K to 0.06 K. The ADR is designed so that it can absorb the heat on the detector stage for at least 24 hours before it must stop, warm up to the helium bath temperature (1.3 K), and dump the accumulated heat. Future detector arrays will be much larger and will have higher heat dissipation. Furthermore, future missions will use mechanical cryocoolers to provide upper stage cooling, but they can only reach 4 - 10 K. Trying to scale heavy (-15 kg) single stage ADRs up to the higher heat loads and higher heat rejection temperatures required leads to unacceptably large systems. The GSFC Cryogenics Branch has developed the Continuous ADR (CADR) to solve this problem. The CADR consists of a series of ADR stages that sequentially pass heat from the load up to the high temperature heat sink. The stage connected to the load remains at a constant temperature. The continuous stage effectively decouples detector operation from ADR operation, allowing the ADR stages to be cycled much more rapidly. Rapid cycling leads to higher cooling power density. The cascading, multistage arrangement allows the magnetic refrigerant of each stage to be optimized for its own temperature swing. In the past year, we have made good progress toward a 0.05 to 10K system. A four-stage system that operates from 4.2 K was demonstrated. Magnetic shielding was added to eliminate inter-stage coupling. Improvements were made to superconducting and passive gas-gap heat switches. A second type of passive gas gap switch, one meant for use at higher temperature, was demonstrated. The presentation will focus primarily on these recent design improvements, and on the challenges that remain on the progress toward a system that will operate from 10 K or higher.
Integrated Evaluation of Closed Loop Air Revitalization System Components
NASA Technical Reports Server (NTRS)
Murdock, K.
2010-01-01
NASA s vision and mission statements include an emphasis on human exploration of space, which requires environmental control and life support technologies. This Contractor Report (CR) describes the development and evaluation of an Air Revitalization System, modeling and simulation of the components, and integrated hardware testing with the goal of better understanding the inherent capabilities and limitations of this closed loop system. Major components integrated and tested included a 4-Bed Modular Sieve, Mechanical Compressor Engineering Development Unit, Temperature Swing Adsorption Compressor, and a Sabatier Engineering and Development Unit. The requisite methodolgy and technical results are contained in this CR.
NASA Technical Reports Server (NTRS)
Hasseeb, Hashmatullah; Iannetti, Anthony
2017-01-01
Mars ISRU converts atmospheric CO2 to generate O2 and CH4. Reduces launch mass, thus mission cost. Increases mission duration and independence. CO2 acquisition system must: a) Reliably extract CO2 over the varying Martian environment. 1) approx. 0.67-0.93 kPa pressure and 2) 125 C to 40 C. b) Provide and compress high purity gas to chemical plants. 1) Separate N2, Ar2, etc. from approx. 95% CO2 atmosphere and 2) Current pressure targets: 50 kPa-500 kPa.
Demonstration of Metabolic Heat Regenerated Temperature Swing Adsorption Technology
NASA Technical Reports Server (NTRS)
Paul, Heather; Iacomini, Christine; Powers, Aaron; Dunham, Jonah; Straub-Lopez, Katie; Anerson, Grant; MacCallum, Taber
2007-01-01
Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is currently being investigated for removal and rejection of CO2 and heat from a Portable Life Support System (PLSS) to a Martian environment. The metabolically-produced CO2 present in the vent loop gas is collected using a CO2 selective adsorbent that has been cooled via a heat exchanger to near CO2 sublimation temperatures (approx.195K) with liquid CO2 obtained from Martian resources. Once the adsorbent is fully loaded, fresh warm, moist vent loop (approx.300K) is used to heat the adsorbent via another heat exchanger. The adsorbent will then reject the collected CO2 to the Martian ambient. Two beds are used to achieve continuous CO2 removal by cycling between the cold and warm conditions for adsorbent loading and regeneration, respectively. Small experiments have already been completed to show that an adsorbent can be cycled between these PLSS operating conditions to provide adequate conditions for CO2 removal from a simulated vent loop. One of the remaining technical challenges is extracting enough heat from the vent loop to warm the adsorbent in an appreciable time frame to meet the required adsorb/desorb cycle. The other key technical aspect of the technology is employing liquid CO2 to achieve the appropriate cooling. A technology demonstrator has been designed, built and tested to investigate the feasibility of 1) warming the adsorbent using the moist vent loop, 2) cooling the adsorbent using liquid CO2, and 3) using these two methods in conjunction to successfully remove CO2 from a vent loop and reject it to Mars ambient. Both analytical and numerical methods were used to perform design calculations and trades. The demonstrator was built and tested. The design analysis and testing results are presented along with recommendations for future development required to increase the maturity of the technology.
Agricultural and Ranching area, Rio Sao Francisco, Brazil
1990-12-10
STS035-73-082 (2-10 Dec 1990) --- This agricultural and ranching area, Rio Sao Francisco, Brazil (13.0S, 43.5W) has been under study for several years. See scene STS-31-92-045 for comparison. This area has many small single family subsistence farms, large square and rectangular commercial farms and pastures for livestock grazing. Over the several years of observation, the number and size of farms has increased and center-pivot, swing-arm irrigation systems have been installed.
Combined Electromagnetic and Magnetometer Data Acquisition and Processing
2004-10-27
the crankshaft and camshafts are steel, the use of ferromagnetic materials on the vehicle have been kept to an absolute minimum to reduce the magnetic...directly to the platform, while the lower coils are free to swing backward if they encounter an obstacle such as a large rock, rut, or tree trunk or...magnetometer/EM61 system was run over these items. The parking lot behind the building is ringed by trees , so RTK-quality GPS is far from assured
25. VIEW EAST IN BRIDGE TENDER'S HOUSE, (left) ORIGINAL LEVERS ...
25. VIEW EAST IN BRIDGE TENDER'S HOUSE, (left) ORIGINAL LEVERS FOR GASOLINE ENGINE OPERATION OF SWING-SPAN, (right) PANEL F ELECTRIC OPERATION OF GATES AND SWING-SPAN; new bridge located in background - Tipers Bridge, Spanning Great Wicomico River at State Route 200, Kilmarnock, Lancaster County, VA
Directly induced swing for closed loop control of electroslag remelting furnace
Damkroger, Brian
1998-01-01
An apparatus and method for controlling an electroslag remelting furnace, imposing a periodic fluctuation on electrode drive speed and thereby generating a predictable voltage swing signal. The fluctuation is preferably done by imposition of a sine, square, or sawtooth wave on the drive dc offset signal.
On the integrability of the motion of 3D-Swinging Atwood machine and related problems
NASA Astrophysics Data System (ADS)
Elmandouh, A. A.
2016-03-01
In the present article, we study the problem of the motion of 3D- Swinging Atwood machine. A new integrable case for this problem is announced. We point out a new integrable case describing the motion of a heavy particle on a titled cone.
D'Angelo, Giuseppe; Thibaudier, Yann; Telonio, Alessandro; Hurteau, Marie-France; Kuczynski, Victoria; Dambreville, Charline
2014-01-01
Stepping along curvilinear paths produces speed differences between the inner and outer limb(s). This can be reproduced experimentally by independently controlling left and right speeds with split-belt locomotion. Here we provide additional details on the pattern of the four limbs during quadrupedal split-belt locomotion in intact cats. Six cats performed tied-belt locomotion (same speed bilaterally) and split-belt locomotion where one side (constant side) stepped at constant treadmill speed while the other side (varying side) stepped at several speeds. Cycle, stance, and swing durations changed in parallel in homolateral limbs with shorter and longer stance and swing durations on the fast side, respectively, compared with the slow side. Phase variations were quantified in all four limbs by measuring the slopes of the regressions between stance and cycle durations (rSTA) and between swing and cycle durations (rSW). For a given limb, rSTA and rSW were not significantly different from one another on the constant side whereas on the varying side rSTA increased relative to tied-belt locomotion while rSW became more negative. Phase variations were similar for homolateral limbs. Increasing left-right speed differences produced a large increase in homolateral double support on the slow side, while triple-support periods decreased. Increasing left-right speed differences altered homologous coupling, homolateral coupling on the fast side, and coupling between the fast hindlimb and slow forelimb. Results indicate that homolateral limbs share similar control strategies, only certain features of the interlimb pattern adjust, and spinal locomotor networks of the left and right sides are organized symmetrically. PMID:25031257
Synchoronous inter-hemispheric alpine glacier advances during the Late Glacial?
NASA Astrophysics Data System (ADS)
Bakke, Jostein; Paasche, Øyvind
2016-04-01
The termination of the last glaciation in both hemispheres was a period of rapid climate swings superimposed on the overall warming trend, resulting from large-scale reorganizations of the atmospheric and oceanic circulation patterns in both hemispheres. Environmental changes during the deglaciation have been inferred from proxy records, as well as by model simulations. Several oscillations took place both in northern and southern hemispheres caused by melt water releases such as during the Younger Dryas in north and the Antarctic Cold Reversal in south. However, a consensus on the hemispheric linkages through ocean and atmosphere are yet to be reached. Here we present a new multi-proxy reconstruction from a sub-annually resolved lake sediment record from Lake Lusvatnet in Arctic Norway compared with a new reconstruction from the same time interval at South Georgia, Southern Ocean, suggesting inter-hemispheric climate linkages during the Bølling/Allerød time period. Our reconstruction of the alpine glacier in the lake Lusvatnet catchment show a synchronous glacier advance with the Birch-hill moraine complex in the Southern Alps, New Zealand during the Intra Allerød Cooling period. We propose these inter hemispheric climate swings to be forced by the northward migration of the southern Subtropical Front during the Antarctic Cold Reversal. Such a northward migration of the Subtropical Front is shown in model simulation and in palaeorecords to reduce the Agulhas leakage impacting the strength of the Atlantic meridional overturning circulation. We simply ask if this can be the carrier of rapid climate swings from one hemisphere to another? Our high-resolution reconstructions provide the basis for an enhanced understanding of the tiny balance between migration of the Subtropical Front in the Southern Ocean and the teleconnection to northern hemisphere.
Simulation of aerodynamic noise and vibration noise in hard disk drives
NASA Astrophysics Data System (ADS)
Zhu, Lei; Shen, Sheng-Nan; Li, Hui; Zhang, Guo-Qing; Cui, Fu-Hao
2018-05-01
Internal flow field characteristics of HDDs are usually influenced by the arm swing during seek operations. This, in turn, can affect aerodynamic noise and airflow-induced noise. In this paper, the dynamic mesh method is used to calculate the flow-induced vibration (FIV) by transient structure analysis and the boundary element method (BEM) is utilized to predict the vibration noise. Two operational states are considered: the arm is fixed and swinging over the disk. Both aerodynamic noise and vibration noise inside drives increase rapidly with increase in disk rotation and arm swing velocities. The largest aerodynamic noise source is always located near the arm and swung with the arm.
Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.
Chino, N; Pearson, J R; Cockrell, J L; Mikishko, H A; Koepke, G H
1975-01-01
Negative pressures in the small space between the distal stump and the below-knee prosthetic socket were measured during swing phase for a series of nine subjects. A molded rubber sleeve connecting the prosthesis and the thigh was found to enhance this effect so that suction suspension occurred during the entire swing phase. Deterioration of the suction occurred when the sleeve was intentionally pierced, and when other suspensions such as a suprapatellar cuff or thigh band were tested. The findings indicate that the total-contact socket, gel liner and elastic sleeve combine to create suction in the below-knee socket which improves overall comfort and function for the patient in using the prosthesis.
NASA Astrophysics Data System (ADS)
Feng, Linrun; Tang, Wei; Zhao, Jiaqing; Yang, Ruozhang; Hu, Wei; Li, Qiaofeng; Wang, Ruolin; Guo, Xiaojun
2016-02-01
With its excellent mechanical flexibility, low-cost and low-temperature processing, the solution processed organic field-effect transistor (OFET) is a promising platform technology for developing ubiquitous sensor applications in digital health, environment monitoring and Internet of Things. However, a contradiction between achieving low voltage operation and having stable performance severely hinder the technology to become commercially viable. This work shows that, by reducing the sub-gap density of states (DOS) at the channel for low operation voltage and using a proper low-k non-polar polymer dielectric layer, such an issue can be addressed. Stable electrical properties after either being placed for weeks or continuously prolonged bias stressing for hours in ambient air are achieved for all solution processed unencapsulated OFETs with the channel being exposed to the ambient air for analyte detection. The fabricated device presents a steep subthreshold swing less than 100 mV/decade, and an ON/OFF ratio of 106 at a voltage swing of 3 V. The low voltage and stable operation allows the sensor made of the OFET to be incorporated into a battery-powered electronic system for continuously reliable sensing of ammonia vapor in ambient air with very small power consumption of about 50 nW.
Feng, Linrun; Tang, Wei; Zhao, Jiaqing; Yang, Ruozhang; Hu, Wei; Li, Qiaofeng; Wang, Ruolin; Guo, Xiaojun
2016-01-01
With its excellent mechanical flexibility, low-cost and low-temperature processing, the solution processed organic field-effect transistor (OFET) is a promising platform technology for developing ubiquitous sensor applications in digital health, environment monitoring and Internet of Things. However, a contradiction between achieving low voltage operation and having stable performance severely hinder the technology to become commercially viable. This work shows that, by reducing the sub-gap density of states (DOS) at the channel for low operation voltage and using a proper low-k non-polar polymer dielectric layer, such an issue can be addressed. Stable electrical properties after either being placed for weeks or continuously prolonged bias stressing for hours in ambient air are achieved for all solution processed unencapsulated OFETs with the channel being exposed to the ambient air for analyte detection. The fabricated device presents a steep subthreshold swing less than 100 mV/decade, and an ON/OFF ratio of 106 at a voltage swing of 3 V. The low voltage and stable operation allows the sensor made of the OFET to be incorporated into a battery-powered electronic system for continuously reliable sensing of ammonia vapor in ambient air with very small power consumption of about 50 nW. PMID:26861412
Student Learning through Hands-On Industry Projects
ERIC Educational Resources Information Center
Acheson, Lingma Lu
2014-01-01
Learning is most effective when accompanied by doing. If someone desires to become a baseball player, being told how to play the game, watching others play and even understanding the rules of the game are mostly ineffective if the individual never "swings the bat". This paper outlines the implementation of this method (swinging the bat)…
Swedish Defence Acquisition Transformation: A Research Agenda
2015-05-13
presentation • A small country perspective • The swinging pendulum : “From preparedness to deployment to preparedness?” – or “from national defence to PSOs to...history of war The swinging (political) pendulum • A. 200 years of peace – Standing in preparedness • B. Post Cold War – Deployed on PSOs • C
Physics of Swinging a Striking Implement
ERIC Educational Resources Information Center
Cross, Rod
2015-01-01
The act of swinging an object such as a hammer or a tennis racket involves the application of forces and torques in a manner that is intuitively obvious to the person performing the task, but is probably much less obvious to the average physics student. This article describes the basic mechanics of the problem.
NASA Astrophysics Data System (ADS)
Krivoruchenko, Mikhail I.
2009-08-01
Using elementary geometric tools, we apply essentially the same methods to derive expressions for the rotation angle of the swing plane of Foucault's pendulum and the rotation angle of the spin of a relativistic particle moving in a circular orbit (the Thomas precession effect).
High Bar Swing Performance in Novice Adults: Effects of Practice and Talent
ERIC Educational Resources Information Center
Busquets, Albert; Marina, Michel; Irurtia, Alfredo; Ranz, Daniel; Angulo-Barroso, Rosa M.
2011-01-01
An individual's a priori talent can affect movement performance during learning. Also, task requirements and motor-perceptual factors are critical to the learning process. This study describes changes in high bar swing performance after a 2-month practice period. Twenty-five novice participants were divided by a priori talent level…
41. Reconstruction of roadway; view of swing span looking northwest ...
41. Reconstruction of roadway; view of swing span looking northwest from Bronx approach, showing new apron under construction-concrete foundation partly built. Note trolley in background and broken asphalt in roadway bed. December 15, 1925 photograph. - University Heights Bridge, Spanning Harlem River at 207th Street & West Harlem Road, New York County, NY
75 FR 63714 - Drawbridge Operation Regulation; Des Allemands Bayou, LA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-18
... deviation from the regulation governing the operation of the Burlington Northern Santa Fe Railway swing...-671-2128, e-mail [email protected] . If you have questions on viewing the docket, call Renee V... Burlington Northern Santa Fe Railway swing span drawbridge across Bayou Des Allemands, mile 14.0 has a...
Expert Baseball Batters Have Greater Sensitivity in Making Swing Decisions
ERIC Educational Resources Information Center
Gray, Rob
2010-01-01
This study used signal detection theory to conceptualize the problem a baseball batter faces when deciding whether or not to swing at a pitch. It examined the launch angle (LA) criteria used by expert (college players) and less experienced (recreational league players) batters using a baseball batting simulation. This study showed that, although…
Directly induced swing for closed loop control of electroslag remelting furnace
Damkroger, B.
1998-04-07
An apparatus and method are disclosed for controlling an electroslag remelting furnace, imposing a periodic fluctuation on electrode drive speed and thereby generating a predictable voltage swing signal. The fluctuation is preferably done by imposition of a sine, square, or sawtooth wave on the drive dc offset signal. 8 figs.
Measurement of centering error for probe of swing arm profilometer using a spectral confocal sensor
NASA Astrophysics Data System (ADS)
Chen, Lin; Jing, Hongwei; Wei, Zhongwei; Cao, Xuedong
2015-02-01
A spectral confocal sensor was used to measure the centering error for probe of swing arm profilometer (SAP). The feasibility of this technology was proved through simulation and experiment. The final measurement results was also analyzed to evaluate the advantages and disadvantages of this technology.
Pressure Swing Adsorption in the Unit Operations Laboratory
ERIC Educational Resources Information Center
Ganley, Jason
2018-01-01
This paper describes a student laboratory in the Unit Operations Laboratory at the Colorado School of Mines: air separation by pressure swing adsorption. The flexibility of the system enables students to study the production of enriched nitrogen or oxygen streams. Automatic data acquisition permits the study of cycle steps and performance.…
Getting into the Swing of Things: Using Pendulums to Learn the Scientific Method.
ERIC Educational Resources Information Center
Grambo, Gregory
1996-01-01
A middle school science teacher describes the learning and thinking processes of his class as they worked and played with pendulums and learned to build a swing that could tell time. The article illustrates how students can learn the value of the scientific method for problem solving. (DB)
Aerial view of the entire bridge crossing the Tennessee River ...
Aerial view of the entire bridge crossing the Tennessee River looking up river. The swing bridge, when open, permits river navigational traffic to ply the river. Construction of a replacement bridge, to be located 93.27 feet down river, has now started. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
"Gunslinger's gait": a new cause of unilaterally reduced arm swing.
Araújo, Rui; Ferreira, Joaquim J; Antonini, Angelo; Bloem, Bastiaan R
2015-12-14
To postulate a new possible cause of a unilaterally reduced arm swing in addition to the known medical conditions such as shoulder pathology, Erb's palsy, stroke, and Parkinson's disease. Analysis of YouTube videos depicting the gait of highly ranked Russian officials. We found a similar walking pattern in President Vladimir Putin, Prime Minister Dmitry Medvedev and three other highly ranked Russian officials, all presenting with a consistently reduced right arm swing in the absence of other overt neurological abnormalities. We propose that this new gait pattern, which we term "gunslinger's gait," may result from a behavioural adaptation, possibly triggered by KGB or other forms of weapons training where trainees are taught to keep their right hand close to the chest while walking, allowing them to quickly draw a gun when faced with a foe. This should be included in the differential diagnosis of a unilaterally reduced arm swing. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Pricing of swing options: A Monte Carlo simulation approach
NASA Astrophysics Data System (ADS)
Leow, Kai-Siong
We study the problem of pricing swing options, a class of multiple early exercise options that are traded in energy market, particularly in the electricity and natural gas markets. These contracts permit the option holder to periodically exercise the right to trade a variable amount of energy with a counterparty, subject to local volumetric constraints. In addition, the total amount of energy traded from settlement to expiration with the counterparty is restricted by a global volumetric constraint. Violation of this global volumetric constraint is allowed but would lead to penalty settled at expiration. The pricing problem is formulated as a stochastic optimal control problem in discrete time and state space. We present a stochastic dynamic programming algorithm which is based on piecewise linear concave approximation of value functions. This algorithm yields the value of the swing option under the assumption that the optimal exercise policy is applied by the option holder. We present a proof of an almost sure convergence that the algorithm generates the optimal exercise strategy as the number of iterations approaches to infinity. Finally, we provide a numerical example for pricing a natural gas swing call option.
Coordinated weather balloon solar radiation measurements during a solar eclipse
2016-01-01
Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes. This article is part of the themed issue ‘Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse’. PMID:27550757
Can-out hatch assembly and positioning system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basnar, P.J.; Frank, R.C.; Hoh, J.C.
1985-07-03
A can-out hatch assembly is adapted to engage in a sealed manner the upper end of a covered sealed container around an aperture in a sealed chamber and to remove the cover from the container permitting a contaminant to be transferred between the container and the chamber while isolating internal portions of the container and chamber from the surrounding environment. A swing bracket is coupled at a first end thereof to the inner, lower wall of the sealed container adjacent to the aperture therein. To a second end of the swing bracket is mounted a hatch cover which may bemore » positioned in sealed engagement about the chamber's aperture by rotating the hatch cover in a first direction when the swing bracket is in the full down position. Rotation of the hatch cover in a second direction release it from sealed engagement with the chamber's aperture. A lid support rod also coupled to the second end of the swing bracket and inserted through an aperture in the center of the hatch cover may be rotated for theadably engaging the container's cover whereupon the cover may be removed from the container and the hatch cover displaced from the aperture by pivoting displacement of the swing bracket. The contaminant may then be either removed from the container and placed within the sealed chamber, or vice versa, followed by positioning of the cover upon the container and the hatch cover over the aperture in a sealed manner.« less
Coordinated weather balloon solar radiation measurements during a solar eclipse.
Harrison, R G; Marlton, G J; Williams, P D; Nicoll, K A
2016-09-28
Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'. © 2016 The Authors.
Can-out hatch assembly and positioning system
Basnar, P.J.; Frank, R.C.; Hoh, J.C.
1985-07-03
A can-out hatch assembly is adapted to engage in a sealed manner the upper end of a covered sealed container around an aperture in a sealed chamber and to remove the cover from the container permitting a contaminant to be transferred between the container and the chamber while isolating internal portions of the container and chamber from the surrounding environment. A swing bracket is coupled at a first end thereof to the inner, lower wall of the sealed container adjacent to the aperture therein. To a second end of the swing bracket is mounted a hatch cover which may be positioned in sealed engagement about the chamber's aperture by rotating the hatch cover in a first direction when the swing bracket is in the full down position. Rotation of the hatch cover in a second direction release it from sealed engagement with the chamber's aperture. A lid support rod also coupled to the second end of the swing bracket and inserted through an aperture in the center of the hatch cover may be rotated for theadably engaging the container's cover whereupon the cover may be removed from the container and the hatch cover displaced from the aperture by pivoting displacement of the swing bracket. The contaminant may then be either removed from the container and placed within the sealed chamber, or vice versa, followed by positioning of the cover upon the container and the hatch cover over the aperture in a sealed manner.
Can-out hatch assembly and positioning system
Basnar, Paul J.; Frank, Robert C.; Hoh, Joseph C.
1986-01-01
A can-out hatch assembly is adapted to engage in a sealed manner the upper end of a covered sealed container around an aperture in a sealed chamber and to remove the cover from the container permitting a contaminant to be transferred between the container and the chamber while isolating internal portions of the container and chamber from the surrounding environment. A swing bracket is coupled at a first end thereof to the inner, lower wall of the sealed container adjacent to the aperture therein. To a second end of the swing bracket is mounted a hatch cover which may be positioned in sealed engagement about the chamber's aperture by rotating the hatch cover in a first direction when the swing bracket is in the full down position. Rotation of the hatch cover in a second direction releases it from sealed engagement with the chamber's aperture. A lid support rod also coupled to the second end of the swing bracket and inserted through an aperture in the center of the hatch cover may be rotated for threadably engaging the container's cover whereupon the cover may be removed from the container and the hatch cover displaced from the aperture by pivoting displacement of the swing bracket. The contaminant may then be either removed from the container and placed within the sealed chamber, or vice versa, followed by positioning of the cover upon the container and the hatch cover over the aperture in a sealed manner.
Can-out hatch assembly and positioning system
Basnar, Paul J.; Frank, Robert C.; Hoh, Joseph C.
1986-01-07
A can-out hatch assembly is adapted to engage in a sealed manner the upper end of a covered sealed container around an aperture in a sealed chamber and to remove the cover from the container permitting a contaminant to be transferred between the container and the chamber while isolating internal portions of the container and chamber from the surrounding environment. A swing bracket is coupled at a first end thereof to the inner, lower wall of the sealed container adjacent to the aperture therein. To a second end of the swing bracket is mounted a hatch cover which may be positioned in sealed engagement about the chamber's aperture by rotating the hatch cover in a first direction when the swing bracket is in the full down position. Rotation of the hatch cover in a second direction releases it from sealed engagement with the chamber's aperture. A lid support rod also coupled to the second end of the swing bracket and inserted through an aperture in the center of the hatch cover may be rotated for threadably engaging the container's cover whereupon the cover may be removed from the container and the hatch cover displaced from the aperture by pivoting displacement of the swing bracket. The contaminant may then be either removed from the container and placed within the sealed chamber, or vice versa, followed by positioning of the cover upon the container and the hatch cover over the aperture in a sealed manner.
The Biomechanics of the Modern Golf Swing: Implications for Lower Back Injuries.
Cole, Michael H; Grimshaw, Paul N
2016-03-01
The modern golf swing is a complex and asymmetrical movement that places an emphasis on restricting pelvic turn while increasing thorax rotation during the backswing to generate higher clubhead speeds at impact. Increasing thorax rotation relative to pelvic rotation preloads the trunk muscles by accentuating their length and allowing them to use the energy stored in their elastic elements to produce more power. As the thorax and pelvis turn back towards the ball during the downswing, more skilled golfers are known to laterally slide their pelvis toward the target, which further contributes to final clubhead speed. However, despite the apparent performance benefits associated with these sequences, it has been argued that the lumbar spine is incapable of safely accommodating the forces they produce. This notion supports a link between the repeated performance of the golf swing and the development of golf-related low back injuries. Of the complaints reported by golfers, low back injuries continue to be the most prevalent, but the mechanism of these injuries is still poorly understood. This review highlights that there is a paucity of research directly evaluating the apparent link between the modern golf swing and golf-related low back pain. Furthermore, there has been a general lack of consensus within the literature with respect to the methods used to objectively assess the golf swing and the methods used to derived common outcome measures. Future research would benefit from a clear set of guidelines to help reduce the variability between studies.
The hindlimb in walking horses: 2. Net joint moments and joint powers.
Clayton, H M; Hodson, E; Lanovaz, J L; Colborne, G R
2001-01-01
The objective of the study was to describe net joint moments and joint powers in the equine hindlimb during walking. The subjects were 5 sound horses. Kinematic and force data were collected synchronously and combined with morphometric information to determine net joint moments at each hindlimb joint throughout stance and swing. The results showed that the net joint moment was on the caudal/plantar side of all hindlimb joints at the start of stance when the limb was being actively retracted. It moved to the cranial/dorsal side around 24% stride at the hip and stifle and in terminal stance at the more distal joints. It remained on the cranial/dorsal side of all joints during the first half of swing to provide active limb protraction, then moved to the caudal/plantar aspect to reverse the direction of limb motion prior to ground contact. The hip joint was the main source of energy generation throughout the stride. It was assisted by the tarsal joint in both stance and swing phases and by the fetlock joint during the stance phase. The coffin joint acted as an energy damper during stance, whereas the stifle joint absorbed almost equal amounts of energy in the stance and swing phases. The coffin and fetlock joints absorbed energy as the limb was protracted and retracted during the swing phase, suggesting that their movements were driven by inertial forces. Future studies will apply these findings to detect changes in the energy profiles due to specific soft tissue injuries.
NASA Technical Reports Server (NTRS)
Bower, Chad; Padilla, Sebastian; Iacomini, Christie; Paul, Heather L.
2010-01-01
This paper details the validation of modeling methods for the three core components of a Metabolic heat regenerated Temperature Swing Adsorption (MTSA) subassembly, developed for use in a Portable Life Support System (PLSS). The first core component in the subassembly is a sorbent bed, used to capture and reject metabolically produced carbon dioxide (CO2). The sorbent bed performance can be augmented with a temperature swing driven by a liquid CO2 (LCO2) sublimation heat exchanger (SHX) for cooling the sorbent bed, and a condensing, icing heat exchanger (CIHX) for warming the sorbent bed. As part of the overall MTSA effort, scaled design validation test articles for each of these three components have been independently tested in laboratory conditions. Previously described modeling methodologies developed for implementation in Thermal Desktop and SINDA/FLUINT are reviewed and updated, their application in test article models outlined, and the results of those model correlations relayed. Assessment of the applicability of each modeling methodology to the challenge of simulating the response of the test articles and their extensibility to a full scale integrated subassembly model is given. The independent verified and validated modeling methods are applied to the development of a MTSA subassembly prototype model and predictions of the subassembly performance are given. These models and modeling methodologies capture simulation of several challenging and novel physical phenomena in the Thermal Desktop and SINDA/FLUINT software suite. Novel methodologies include CO2 adsorption front tracking and associated thermal response in the sorbent bed, heat transfer associated with sublimation of entrained solid CO2 in the SHX, and water mass transfer in the form of ice as low as 210 K in the CIHX.
Behavior of a nuclear steel containment equipment hatch at large strain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanous, F.; Greimann, L.
1988-05-01
During a severe accident, buckling of a steel containment hatch door, large deformation and ovaling of the hatch sleeve are potential causes of mismatch at the sealing surface which can result in a leakage path. A three-dimensional nonlinear finite element analysis of a typical steel containment/sleeve/hatch assembly that includes containment stiffeners, pretensioned swing bolts, and hatch door geometric imperfection is presented. The analysis was carried out to the nonlinear range up to large strains. The results indicated that the buckling load occurs at pressure, far above that which causes gross yielding of the shell plate. Although buckling of the hatchmore » door increased the relative motions of the hatch sleeve and the hatch door, the motions remained sufficiently small to prevent leakage.« less
Variable-Speed Power-Turbine for the Large Civil Tilt Rotor
NASA Technical Reports Server (NTRS)
Suchezky, Mark; Cruzen, G. Scott
2012-01-01
Turbine design concepts were studied for application to a large civil tiltrotor transport aircraft. The concepts addressed the need for high turbine efficiency across the broad 2:1 turbine operating speed range representative of the notional mission for the aircraft. The study focused on tailoring basic turbine aerodynamic design design parameters to avoid the need for complex, heavy, and expensive variable geometry features. The results of the study showed that good turbine performance can be achieved across the design speed range if the design focuses on tailoring the aerodynamics for good tolerance to large swings in incidence, as opposed to optimizing for best performance at the long range cruise design point. A rig design configuration and program plan are suggested for a dedicated experiment to validate the proposed approach.
Bi-layer Channel AZO/ZnO Thin Film Transistors Fabricated by Atomic Layer Deposition Technique.
Li, Huijin; Han, Dedong; Liu, Liqiao; Dong, Junchen; Cui, Guodong; Zhang, Shengdong; Zhang, Xing; Wang, Yi
2017-12-01
This letter demonstrates bi-layer channel Al-doped ZnO/ZnO thin film transistors (AZO/ZnO TFTs) via atomic layer deposition process at a relatively low temperature. The effects of annealing in oxygen atmosphere at different temperatures have also been investigated. The ALD bi-layer channel AZO/ZnO TFTs annealed in dry O 2 at 300 °C exhibit a low leakage current of 2.5 × 10 -13 A, I on /I off ratio of 1.4 × 10 7 , subthreshold swing (SS) of 0.23 V/decade, and high transmittance. The enhanced performance obtained from the bi-layer channel AZO/ZnO TFT devices is explained by the inserted AZO front channel layer playing the role of the mobility booster.
Zinc Oxide Thin-Film Transistors
NASA Astrophysics Data System (ADS)
Fortunato, E.; Barquinha, P.; Pimentel, A.; Gonçalves, A.; Marques, A.; Pereira, L.; Martins, R.
ZnO thin film transistors (ZnO-TFT) have been fabricated by rf magnetron sputtering at room temperature with a bottom-gate configuration. The ZnO-TFT operates in the enhancement mode with a threshold voltage of 21 V, a field effect mobility of 20 cm2/Vs, a gate voltage swing of 1.24 V/decade and an on/off ratio of 2×105. The ZnO-TFT present an average optical transmission (including the glass substrate) of 80 % in the visible part of the spectrum. The combination of transparency, high channel mobility and room temperature processing makes the ZnO-TFT a very promising low cost optoelectronic device for the next generation of invisible and flexible electronics. Moreover, the processing technology used to fabricate this device is relatively simple and it is compatible with inexpensive plastic/flexible substrate technology.
High Mobility Thin Film Transistors Based on Amorphous Indium Zinc Tin Oxide
Noviyana, Imas; Lestari, Annisa Dwi; Putri, Maryane; Won, Mi-Sook; Bae, Jong-Seong; Heo, Young-Woo; Lee, Hee Young
2017-01-01
Top-contact bottom-gate thin film transistors (TFTs) with zinc-rich indium zinc tin oxide (IZTO) active layer were prepared at room temperature by radio frequency magnetron sputtering. Sintered ceramic target was prepared and used for deposition from oxide powder mixture having the molar ratio of In2O3:ZnO:SnO2 = 2:5:1. Annealing treatment was carried out for as-deposited films at various temperatures to investigate its effect on TFT performances. It was found that annealing treatment at 350 °C for 30 min in air atmosphere yielded the best result, with the high field effect mobility value of 34 cm2/Vs and the minimum subthreshold swing value of 0.12 V/dec. All IZTO thin films were amorphous, even after annealing treatment of up to 350 °C. PMID:28773058
Method of interplanetary trajectory optimization for the spacecraft with low thrust and swing-bys
NASA Astrophysics Data System (ADS)
Konstantinov, M. S.; Thein, M.
2017-07-01
The method developed to avoid the complexity of solving the multipoint boundary value problem while optimizing interplanetary trajectories of the spacecraft with electric propulsion and a sequence of swing-bys is presented in the paper. This method is based on the use of the preliminary problem solutions for the impulsive trajectories. The preliminary problem analyzed at the first stage of the study is formulated so that the analysis and optimization of a particular flight path is considered as the unconstrained minimum in the space of the selectable parameters. The existing methods can effectively solve this problem and make it possible to identify rational flight paths (the sequence of swing-bys) to receive the initial approximation for the main characteristics of the flight path (dates, values of the hyperbolic excess velocity, etc.). These characteristics can be used to optimize the trajectory of the spacecraft with electric propulsion. The special feature of the work is the introduction of the second (intermediate) stage of the research. At this stage some characteristics of the analyzed flight path (e.g. dates of swing-bys) are fixed and the problem is formulated so that the trajectory of the spacecraft with electric propulsion is optimized on selected sites of the flight path. The end-to-end optimization is carried out at the third (final) stage of the research. The distinctive feature of this stage is the analysis of the full set of optimal conditions for the considered flight path. The analysis of the characteristics of the optimal flight trajectories to Jupiter with Earth, Venus and Mars swing-bys for the spacecraft with electric propulsion are presented. The paper shows that the spacecraft weighing more than 7150 kg can be delivered into the vicinity of Jupiter along the trajectory with two Earth swing-bys by use of the space transportation system based on the "Angara A5" rocket launcher, the chemical upper stage "KVTK" and the electric propulsion system with input electrical power of 100 kW.
The "swing-ding": a golf-related head injury in children.
Wang, Arthur; Cohen, Alan R; Robinson, Shenandoah
2011-01-01
In recent years there has been an increased incidence of golf-associated head injuries in children and adolescents. At the authors' institution, they have identified a unique pattern of head injury associated with a swinging golf club. In this study, the authors highlight the mechanism of this injury and report their experience treating it. The authors reviewed the database of Rainbow Babies and Children's Hospital Trauma Center and performed a retrospective analysis of golf injuries recorded over a 10-year period (January 2000-April 2010). They identified 13 children (9 boys and 4 girls) who sustained head injuries in golfing accidents. All patients were 10 years of age or younger. The medical charts were reviewed and follow-up interviews were conducted to better delineate the details of the injuries. Injuries included 13 depressed skull fractures, 7 epidural hematomas, and 1 cerebral contusion. All 13 patients sustained their injuries after being struck in the head by a golf club. Seven sustained injuries on the follow-through of the initial swing and 3 sustained injuries on the backswing. All but one patient required neurosurgical intervention. Five patients developed neurological sequelae. None of the children had prior experience with golf equipment. All but one injury occurred in the child's own backyard. There was no direct supervision by an adult in any of the cases. Golfing can lead to serious head injuries in children. The authors noticed a unique pattern of golf-related head injuries, previously not described, that they have termed the "swing-ding." This golf club-inflicted injury occurs when a child stands too close to a swinging golfer and is struck in the head, subsequently sustaining a comminuted depressed skull fracture in the frontal or temporal region, with or without further intracranial injury. The study suggests that a lack of adult supervision, minimal previous golf experience, and proximity of the child to the swinging golfer are all implicated in this head injury pattern.
FORTNER, HOWARD A.; SALGADO, JEANETTE M.; HOLMSTRUP, ANGELICA M.; HOLMSTRUP, MICHAEL E.
2014-01-01
Tabata (TAB) training, consisting of eight cycles of 20 seconds of maximal exercise followed by 10 seconds of rest, is time-efficient, with aerobic and anaerobic benefit. This study investigated the cardiovascular and metabolic demands of a TAB versus traditional (TRAD) resistance protocol with the kettlebell swing. Fourteen young (18–25y), non-obese (BMI 25.7±0.8 kg/m2) participants reported on three occasions. All testing incorporated measurements of HR, oxygen consumption, and blood lactate accumulation. Each participant completed Tabata kettlebell swings (male- 8kg, female- 4.5kg; 8 intervals; 20s maximal repetitions, 10s rest). On a subsequent visit (TRAD), the total swings from the TAB protocol were evenly divided into 4 sets, with 90s rest between sets. Outcome measures were compared using paired t-tests. The TAB was completed more quickly than the TRAD protocol (240.0±0.0 v. 521.5±3.3 sec, P<0.01), at a higher perceived exertion (Borg RPE; 15.1±0.7 v. 11.7±0.9, P<0.01). The TAB elicited a higher average VO2 value (33.1±1.5 v. 27.2±1.6 ml/kg/min, P<0.01), percent of VO2peak achieved (71.0±0.3 v. 58.4±0.3%, P<0.01), maximal HR (162.4±4.6 v. 145.6±4.8 bpm, P<0.01), and post-exercise blood lactate concentration (6.4±1.1 v. 3.7±0.5 mmol/L, P<0.01). Conclusion The kettlebell swing demonstrated significantly greater cardiovascular and metabolic responses within a TAB vs. TRAD framework. Appropriate screening and risk stratification are advised before implementing kettlebell swings. PMID:27182402
A study of variable thrust, variable specific impulse trajectories for solar system exploration
NASA Astrophysics Data System (ADS)
Sakai, Tadashi
A study has been performed to determine the advantages and disadvantages of variable thrust and variable Isp (specific impulse) trajectories for solar system exploration. There have been several numerical research efforts for variable thrust, variable Isp, power-limited trajectory optimization problems. All of these results conclude that variable thrust, variable Isp (variable specific impulse, or VSI) engines are superior to constant thrust, constant Isp (constant specific impulse; or CSI) engines. However, most of these research efforts assume a mission from Earth to Mars, and some of them further assume that these planets are circular and coplanar. Hence they still lack the generality. This research has been conducted to answer the following questions: (1) Is a VSI engine always better than a CSI engine or a high thrust engine for any mission to any planet with any time of flight considering lower propellant mass as the sole criterion? (2) If a planetary swing-by is used for a VSI trajectory, is the fuel savings of a VSI swing-by trajectory better than that of a CSI swing-by or high thrust swing-by trajectory? To support this research, an unique, new computer-based interplanetary trajectory calculation program has been created. This program utilizes a calculus of variations algorithm to perform overall optimization of thrust, Isp, and thrust vector direction along a trajectory that minimizes fuel consumption for interplanetary travel. It is assumed that the propulsion system is power-limited, and thus the compromise between thrust and Isp is a variable to be optimized along the flight path. This program is capable of optimizing not only variable thrust trajectories but also constant thrust trajectories in 3-D space using a planetary ephemeris database. It is also capable of conducting planetary swing-bys. Using this program, various Earth-originating trajectories have been investigated and the optimized results have been compared to traditional CSI and high thrust trajectory solutions. Results show that VSI rocket engines reduce fuel requirements for any mission compared to CSI rocket engines. Fuel can be saved by applying swing-by maneuvers for VSI engines; but the effects of swing-bys due to VSI engines are smaller than that of CSI or high thrust engines.
A Web-Based Simulation Tool on The Performance of Different Roofing Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Joe; New, Joshua Ryan; Miller, William A
The Roof Savings Calculator (www.roofcalc.com) provides the general public with a web-based program for calculating the energy savings of different roofing and attic systems on four different building types (residential, office, retail, and warehouse) in 239 US TMY2 locations. The core simulation engine of the RSC is doe2attic, which couples the AtticSim program developed by Oak Ridge National Laboratory with the DOE-2.1E program originally developed by Lawrence Berkeley National Laboratory a widely used whole-building simulation program since the 1980 s. Although simulating heat flows through the roof may seem to be an easy task, simulating the net effect of roofingmore » strategies on building heating and cooling energy use can be quite challenging. Few simulation programs can reliably capture dynamics including an attic or plenum with large day-night temperature swings, high ventilation rates, significant radiant exchange between the roof and the attic floor and thermal interactions when there are ducts in the attic, as is typical in North American buildings. The doe2attic program has been tested against detailed measurements gathered in two residential buildings in Fresno, California from cooling energy use to air and surface temperatures, and heat fluxes of the roof and attic floor. The focus of this paper is on the doe2attic simulation tool, but the user interface of the RSC will also be briefly described.« less
Solid Lubricants and Coatings for Extreme Environments: State-of-the-Art Survey
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa
2007-01-01
An investigation was conducted to survey anticipated requirements for solid lubricants in lunar and Martian environments, as well as the effects of these environments on lubricants and their performance and durability. The success of habitats and vehicles on the Moon and Mars, and ultimately, of the human exploration of and permanent human presence on the Moon and Mars, are critically dependent on the correct and reliable operation of many moving mechanical assemblies and tribological components. The coefficient of friction and lifetime of any lubricant generally vary with the environment, and lubricants have very different characteristics under different conditions. It is essential, therefore, to select the right lubrication technique and lubricant for each mechanical and tribological application. Several environmental factors are hazardous to performance integrity on the Moon and Mars. Potential threats common to both the Moon and Mars are low ambient temperatures, wide daily temperature swings (thermal cycling), solar flux, cosmic radiation, and large quantities of dust. The surface of Mars has the additional challenges of dust storms, winds, and a carbon dioxide atmosphere. Solid lubricants and coatings are needed for lunar and Martian applications, where liquid lubricants are ineffective and undesirable, and these lubricants must perform well in the extreme environments of the Moon, Mars, and space, as well as on Earth, where they will be assembled and tested. No solid lubricants and coatings and their systems currently exist or have been validated that meet these requirements, so new solid lubricants must be designed and validated for these applications.
Prospective versus predictive control in timing of hitting a falling ball.
Katsumata, Hiromu; Russell, Daniel M
2012-02-01
Debate exists as to whether humans use prospective or predictive control to intercept an object falling under gravity (Baurès et al. in Vis Res 47:2982-2991, 2007; Zago et al. in Vis Res 48:1532-1538, 2008). Prospective control involves using continuous information to regulate action. τ, the ratio of the size of the gap to the rate of gap closure, has been proposed as the information used in guiding interceptive actions prospectively (Lee in Ecol Psychol 10:221-250, 1998). This form of control is expected to generate movement modulation, where variability decreases over the course of an action based upon more accurate timing information. In contrast, predictive control assumes that a pre-programmed movement is triggered at an appropriate criterion timing variable. For a falling object it is commonly argued that an internal model of gravitational acceleration is used to predict the motion of the object and determine movement initiation. This form of control predicts fixed duration movements initiated at consistent time-to-contact (TTC), either across conditions (constant criterion operational timing) or within conditions (variable criterion operational timing). The current study sought to test predictive and prospective control hypotheses by disrupting continuous visual information of a falling ball and examining consistency in movement initiation and duration, and evidence for movement modulation. Participants (n = 12) batted a ball dropped from three different heights (1, 1.3 and 1.5 m), under both full-vision and partial occlusion conditions. In the occlusion condition, only the initial ball drop and the final 200 ms of ball flight to the interception point could be observed. The initiation of the swing did not occur at a consistent TTC, τ, or any other timing variable across drop heights, in contrast with previous research. However, movement onset was not impacted by occluding the ball flight for 280-380 ms. This finding indicates that humans did not need to be continuously coupled to vision of the ball to initiate the swing accurately, but instead could use predictive control based on acceleration timing information (TTC2). However, other results provide evidence for movement modulation, a characteristic of prospective control. Strong correlations between movement initiation and duration and reduced timing variability from swing onset to arrival at the interception point, both support compensatory variability. An analysis of modulation within the swing revealed that early in the swing, the movement acceleration was strongly correlated to the required mean velocity at swing onset and that later in the swing, the movement acceleration was again strongly correlated with the current required mean velocity. Rather than a consistent movement initiated at the same time, these findings show that the swing was variable but modulated for meeting the demands of each trial. A prospective model of coupling τ (bat-ball) with τ (ball-target) was found to provide a very strong linear fit for an average of 69% of the movement duration. These findings provide evidence for predictive control based on TTC2 information in initiating the swing and prospective control based on τ in guiding the bat to intercept the ball.
Ding, Xingwei; Qin, Cunping; Song, Jiantao; Zhang, Jianhua; Jiang, Xueyin; Zhang, Zhilin
2017-12-01
Thin-film transistors (TFTs) with atomic layer deposition (ALD) HfZnO (HZO) as channel layer and Al 2 O 3 as gate insulator were successfully fabricated. Compared with ZnO-TFT, the stability of HZO-TFT was obviously improved as Hf doping can suppress the generation of oxygen related defects. The transfer characteristics of TFTs at different temperatures were also investigated, and temperature stability enhancement was observed for the TFT with Hf doping. The density of states (DOS) was calculated based on the experimentally obtained E a , which can explain the experimental observation. A high-field effect mobility of 9.4 cm 2 /Vs, a suitable turn-on voltage of 0.26 V, a high on/off ratio of over 10 7 and a steep sub-threshold swing of 0.3 V/decade were obtained in HZO-TFT. The results showed that temperature stability enhancement in HfZnO thin-film transistors are attributed to the smaller DOS.
NASA Astrophysics Data System (ADS)
Ding, Xingwei; Qin, Cunping; Song, Jiantao; Zhang, Jianhua; Jiang, Xueyin; Zhang, Zhilin
2017-01-01
Thin-film transistors (TFTs) with atomic layer deposition (ALD) HfZnO (HZO) as channel layer and Al2O3 as gate insulator were successfully fabricated. Compared with ZnO-TFT, the stability of HZO-TFT was obviously improved as Hf doping can suppress the generation of oxygen related defects. The transfer characteristics of TFTs at different temperatures were also investigated, and temperature stability enhancement was observed for the TFT with Hf doping. The density of states (DOS) was calculated based on the experimentally obtained E a, which can explain the experimental observation. A high-field effect mobility of 9.4 cm2/Vs, a suitable turn-on voltage of 0.26 V, a high on/off ratio of over 107 and a steep sub-threshold swing of 0.3 V/decade were obtained in HZO-TFT. The results showed that temperature stability enhancement in HfZnO thin-film transistors are attributed to the smaller DOS.
Two-Phase Thermal Switching System for a Small, Extended Duration Lunar Surface Science Platform
NASA Technical Reports Server (NTRS)
Bugby, David C.; Farmer, Jeffery T.; OConnor, Brian F.; Wirzburger, Melissa J.; Abel, Elisabeth D.; Stouffer, Chuck J.
2010-01-01
This paper describes a novel thermal control system for the Warm Electronics Box (WEB) on board a small lunar surface lander intended to support science activities anywhere on the lunar surface for an extended duration of up to 6 years. Virtually all lander electronics, which collectively dissipate about 60 W in the reference mission, are contained within the WEB. These devices must be maintained below 323 K (with a goal of 303 K) during the nearly 15-earth-day lunar day, when surface temperatures can reach 390K, and above 263 K during the nearly 15-earth-day lunar night, when surface temperatures can reach 100K. Because of the large temperature swing from lunar day-to-night, a novel thermal switching system was required that would be able to provide high conductance from WEB to radiator(s) during the hot lunar day and low (or negligible) conductance during the cold lunar night. The concept that was developed consists of ammonia variable conductance heat pipes (VCHPs) to collect heat from WEB components and a polymer wick propylene loop heat pipe (LHP) to transport the collected heat to the radiator(s). The VCHPs autonomously maximize transport when the WEB is warm and autonomously shut down when the WEB gets cold. The LHP autonomously shuts down when the VCHPs shut down. When the environment transitions from lunar night to day, the VCHPs and LHP autonomously turn back on. Out of 26 analyzed systems, this novel arrangement was able to best achieve the combined goals of zero control power, autonomous operation, long life, low complexity, low T, and landed tilt tolerance.
NASA Astrophysics Data System (ADS)
Takenaka, Kosuke; Endo, Masashi; Uchida, Giichiro; Setsuhara, Yuichi
2018-04-01
This work demonstrated the low-temperature control of the oxidation of Amorphous InGaZnOx (a-IGZO) films using inductively coupled plasma as a means of precisely tuning the properties of thin film transistors (TFTs) and as an alternative to post-deposition annealing at high temperatures. The effects of the plasma treatment of the as-deposited a-IGZO films were investigated by assessing the electrical properties of TFTs incorporating these films. A TFT fabricated using an a-IGZO film exposed to an Ar-H2-O2 plasma at substrate temperatures as low as 300 °C exhibited the best performance, with a field effect mobility as high as 42.2 cm2 V-1 s-1, a subthreshold gate voltage swing of 1.2 V decade-1, and a threshold voltage of 2.8 V. The improved transfer characteristics of TFTs fabricated with a-IGZO thin films treated using an Ar-H2-O2 plasma are attributed to the termination of oxygen vacancies around Ga and Zn atoms by OH radicals in the gas phase.
Crenna, Paolo; Cuong, Do Manh; Brénière, Yvon
2001-01-01
The organisation of the muscular activities responsible for the termination of gait, their modulation as a function of the rate of progression and the associated mechanical effects were investigated in normal adults, using EMG, force plate and kinematic recordings. In particular, the braking actions in reaction to a visual cue presented at the instant of heel-strike were analysed quantitatively, with a focus on representative leg and thigh muscles of the weight-supporting (stance) and oscillating (swing) limb, during walk-and-stop trials performed at three different velocities. In the stance limb, the EMG associated with braking started approximately 150 ms after the stop signal and, on average, displayed a distal-to-proximal activation sequence that primarily involved the posterior muscle groups (soleus, SOL, and hamstring, HAM). With the exception of SOL, which showed a single EMG burst, EMG patterns consisted of two or three progressively larger components occurring reciprocally in antagonistic muscles. Increasing walking speed yielded a significant reduction of the activity in distal muscles, and a simultaneous increment in proximal muscles. The mechanical effect of the earlier braking actions, estimated from the backward-directed wave of the horizontal ground reaction force, decreased in a velocity-dependent manner. In the swing limb the braking activities began approximately 330 ms after the stop signal and, on average, revealed a proximal-to-distal activation sequence with the extensor groups (quadriceps, QUAD, and SOL) playing a prominent role. They always consisted of single EMG bursts, largely co-activated in the antagonist muscles. The onset latencies of the individual components showed a close correlation, and the spatio-temporal parameters were always scaled in parallel. Unlike the stance limb, the mechanical braking action associated with the final contact of the swing limb increased with walking speed. The results indicate that the muscle synergies responsible for the rapid termination of gait in response to a ground-contact visual cue are produced by a relatively flexible set of motor commands modulated according to different velocity-dependent strategies in the weight-bearing limb, and by a single, fairly robust motor programme in the swing limb. Mechanical constraints related to the relative position of the centre of foot pressure and centre of body mass at the time the braking commands begin to affect external forces, may condition the difference between the two sides of the body. PMID:11744777
Methodology for the Conduct of a Seismic Risk Mitigation Study.
1985-06-01
indoors . Hanging objects swing. Vibrations like passing of light truck. IV Hanging objects swing. Vibrations like passing of heavy trucks; or...UNCLAS PW2 FU?4Cr1ONAL SBSXIOW OPV TAcflCALSTRATE;C ML1S1N.ULIUVM Emmuccons Prowe demiled bvvskdaww of wampc iuekngmjg s ?.vs 5aswmovcqwSw chat mun be
ERIC Educational Resources Information Center
Wong, Darren; Lee, Paul; Foong, See Kit
2010-01-01
We investigate the electromagnetic induction phenomenon for a "falling," "oscillating" and "swinging" magnet and a coil, with the help of a datalogger. For each situation, we discuss the salient aspects of the phenomenon, with the aid of diagrams, and relate the motion of the magnet to its mathematical and graphical representations. Using various…
24 CFR 3280.405 - Standard for swinging exterior passage doors for use in manufactured homes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... pre-production specimen test in accordance with AAMA 1702.2-95, Voluntary Standard Swinging Exterior... requirements. The design and construction of exterior door units must meet all requirements of AAMA 1702.2-95.... For homes designed to be located in Wind Zones II and III, manufacturers shall design exterior walls...
24 CFR 3280.405 - Standard for swinging exterior passage doors for use in manufactured homes.
Code of Federal Regulations, 2013 CFR
2013-04-01
... pre-production specimen test in accordance with AAMA 1702.2-95, Voluntary Standard Swinging Exterior... requirements. The design and construction of exterior door units must meet all requirements of AAMA 1702.2-95.... For homes designed to be located in Wind Zones II and III, manufacturers shall design exterior walls...
24 CFR 3280.405 - Standard for swinging exterior passage doors for use in manufactured homes.
Code of Federal Regulations, 2011 CFR
2011-04-01
... pre-production specimen test in accordance with AAMA 1702.2-95, Voluntary Standard Swinging Exterior... requirements. The design and construction of exterior door units must meet all requirements of AAMA 1702.2-95.... For homes designed to be located in Wind Zones II and III, manufacturers shall design exterior walls...
24 CFR 3280.405 - Standard for swinging exterior passage doors for use in manufactured homes.
Code of Federal Regulations, 2012 CFR
2012-04-01
... pre-production specimen test in accordance with AAMA 1702.2-95, Voluntary Standard Swinging Exterior... requirements. The design and construction of exterior door units must meet all requirements of AAMA 1702.2-95.... For homes designed to be located in Wind Zones II and III, manufacturers shall design exterior walls...
24 CFR 3280.405 - Standard for swinging exterior passage doors for use in manufactured homes.
Code of Federal Regulations, 2014 CFR
2014-04-01
... pre-production specimen test in accordance with AAMA 1702.2-95, Voluntary Standard Swinging Exterior... requirements. The design and construction of exterior door units must meet all requirements of AAMA 1702.2-95.... For homes designed to be located in Wind Zones II and III, manufacturers shall design exterior walls...
ERIC Educational Resources Information Center
Marrero, Meghan E.; Gunning, Amanda M.; Tazi, Zoila
2014-01-01
Kindergarteners have plenty of opportunities to discover and investigate cause and effect in their own lives and in all subject areas. If it rains, they may not be able to go outside for recess. If they pump harder on the swing, the swing will go faster and higher. In science, they may investigate pushes and pulls; discover how exposure to…
Determination of the optimal conditions for inclination maneuvers using a Swing-by
NASA Astrophysics Data System (ADS)
Moura, O.; Celestino, C. C.; Prado, A. F. B. A.
2018-05-01
The search for methods to reduce the fuel consumption in orbital transfers is something relevant and always current in astrodynamics. Therefore, the maneuvers assisted by the gravity, also called Swing-by maneuvers, can be an advantageous option to save fuel. The proposal of the present research is to explore the influence of some parameters in a Swing-by of an artificial satellite orbiting a planet with one of the moons of this mother planet, with the goal of changing the inclination of the artificial satellite around the main body of the system. The fuel consumption of this maneuver is compared with the required consumption to perform the same change of inclination using the classical approach of impulsive maneuvers.
Aguirre-Ollinger, G; Colgate, J E; Peshkin, M A; Goswami, A
2011-03-01
Many of the current implementations of exoskeletons for the lower extremities are conceived to either augment the user's load-carrying capabilities or reduce muscle activation during walking. Comparatively little research has been conducted on enabling an exoskeleton to increase the agility of lower-limb movements. One obstacle in this regard is the inertia of the exoskeleton's mechanism, which tends to reduce the natural frequency of the human limbs. A control method is presented that produces an approximate compensation of the inertia of an exoskeleton's mechanism. The controller was tested on a statically mounted, single-degree-of-freedom (DOF) exoskeleton that assists knee flexion and extension. Test subjects performed multiple series of leg-swing movements in the context of a computer-based, sprint-like task. A large initial acceleration of the leg was needed for the subjects to track a virtual target on a computer screen. The uncompensated inertia of the exoskeleton mechanism slowed down the transient response of the subjects' limb, in comparison with trials performed without the exoskeleton. The subsequent use of emulated inertia compensation on the exoskeleton allowed the subjects to improve their transient response for the same task.
[The manpower market for physicians in the Nordic countries 1980-2000].
Skoglund, E; Taraldset, A
2000-06-30
The ratio between population and active physicians in the Nordic countries has improved from 488 inhabitants per physician in 1980 to 315 in 2000. There is a large mobility of physicians between the countries, contributing to levelling out swings in demand and supply of manpower. Language and culture being similar, physicians can easily adjust to working in a neighbouring country. Iceland is special in this respect, as a surplus of Icelandic physicians has always found work in the other Nordic countries. Of course, their numbers are small relative to the total number of active physicians in the Nordic countries, now approximately 76,000. The number of students admitted to Nordic medical faculties has changed in line with swings in estimated future demand for manpower. Today, numbers are increasing again; this year, approximately 2,900 students will be admitted. Norway stands apart from the other Nordic countries in terms of medical manpower needs. During the last 20 years there has been a continuous shortage of physicians while all the other countries have been through periods of surplus and unemployment among physicians. Manpower forecasts in the early 1980s underestimated the growth in the health care system and hence the demand for medical manpower.
Gender differences in joint biomechanics during walking: normative study in young adults.
Kerrigan, D C; Todd, M K; Della Croce, U
1998-01-01
The effect of gender on specific joint biomechanics during gait has been largely unexplored. Given the perceived, subjective, and temporal differences in walking between genders, we hypothesized that quantitative analysis would reveal specific gender differences in joint biomechanics as well. Sagittal kinematic (joint motion) and kinetic (joint torque and power) data from the lower limbs during walking were collected and analyzed in 99 young adult subjects (49 females), aged 20 to 40 years, using an optoelectronic motion analysis and force platform system. Kinetic data were normalized for both height and weight. Female and male data were compared graphically and statistically to assess differences in all major peak joint kinematic and kinetic values. Females had significantly greater hip flexion and less knee extension before initial contact, greater knee flexion moment in pre-swing, and greater peak mechanical joint power absorption at the knee in pre-swing (P < 0.0019 for each parameter). Other differences were noted (P < 0.05) that were not statistically significant when accounting for multiple comparisons. These gender differences may provide new insights into walking dynamics and may be important for both clinical and research studies in motivating the development of separate biomechanical reference databases for males and females.
Design and jump phenomenon analysis of an eccentric ring energy harvester
NASA Astrophysics Data System (ADS)
Wang, Yu-Jen; Chen, Chung-De
2013-10-01
This paper presents the development of a wheel-mounted eccentric ring energy harvester that is driven by centripetal and gravitational forces during wheel rotation. The natural frequency of the eccentric ring matches the wheel rotation frequency at any car speed because its character length is designed equal to the wheel radius. Consequently, the eccentric ring oscillates with a relatively large swing angle at the wheel speed to generate high levels of power. The nonlinear dynamic behavior of the eccentric ring is investigated to ensure that the proposed design produces steady swing angles, especially at high wheel speeds. Herein, the jump phenomenon of the dynamic motion of the eccentric ring is analyzed by using the Duffing equation and the linearization process. The discriminant value obtained from the analysis confirms that no jump phenomenon occurs at all wheel speeds if the eccentric ring is properly designed. In the experiment, the eccentric ring is integrated with magnets and a coil set to generate 318-442 μW at constant wheel speeds between 300 and 500 rpm. This shows that the proposed device is a potential power source for low-power wheel-mounted electronics, such as pressure sensors, accelerometers, and thermometers.
von Twickel, Arndt; Büschges, Ansgar; Pasemann, Frank
2011-02-01
This article presents modular recurrent neural network controllers for single legs of a biomimetic six-legged robot equipped with standard DC motors. Following arguments of Ekeberg et al. (Arthropod Struct Dev 33:287-300, 2004), completely decentralized and sensori-driven neuro-controllers were derived from neuro-biological data of stick-insects. Parameters of the controllers were either hand-tuned or optimized by an evolutionary algorithm. Employing identical controller structures, qualitatively similar behaviors were achieved for robot and for stick insect simulations. For a wide range of perturbing conditions, as for instance changing ground height or up- and downhill walking, swing as well as stance control were shown to be robust. Behavioral adaptations, like varying locomotion speeds, could be achieved by changes in neural parameters as well as by a mechanical coupling to the environment. To a large extent the simulated walking behavior matched biological data. For example, this was the case for body support force profiles and swing trajectories under varying ground heights. The results suggest that the single-leg controllers are suitable as modules for hexapod controllers, and they might therefore bridge morphological- and behavioral-based approaches to stick insect locomotion control.
Martin, Miriam S; Kline, Helen C; Wagner, Dana R; Alexander, Lacey R; Edwards-Callaway, Lily N; Grandin, Temple
2018-05-03
The objective of this study was to assess the effects of captive bolt length and breed type on post-stun leg activity in cattle. A total of 2850 Holstein (HOL) and non-Holstein British/Continental bred (NHOL) steers and heifers were observed post-stunning at a large commercial slaughter facility. A pneumatically powered penetrating captive bolt stunner was used with three different bolt lengths: CON, 15.24 cm; MED, 16.51 cm; and LON, 17.78 cm. Hind limb kicking, forelimb activity, take away belt stops, carcass swing and number of knife sticks during exsanguination were recorded for each animal from video recording. Hind limb and forelimb kicks observed ranged from 0 to 25 and 0 to 8, respectively. Analysis of post-stun hind limb and forelimb activity indicated that increasing pneumatically powered penetrating captive bolt length does not decrease post-stun leg activity. There was a higher percentage of cattle experiencing take away belt stops and carcass swing in HOL as compared with NHOL. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Scaling of Device Variability and Subthreshold Swing in Ballistic Carbon Nanotube Transistors
NASA Astrophysics Data System (ADS)
Cao, Qing; Tersoff, Jerry; Han, Shu-Jen; Penumatcha, Ashish V.
2015-08-01
In field-effect transistors, the inherent randomness of dopants and other charges is a major cause of device-to-device variability. For a quasi-one-dimensional device such as carbon nanotube transistors, even a single charge can drastically change the performance, making this a critical issue for their adoption as a practical technology. Here we calculate the effect of the random charges at the gate-oxide surface in ballistic carbon nanotube transistors, finding good agreement with the variability statistics in recent experiments. A combination of experimental and simulation results further reveals that these random charges are also a major factor limiting the subthreshold swing for nanotube transistors fabricated on thin gate dielectrics. We then establish that the scaling of the nanotube device uniformity with the gate dielectric, fixed-charge density, and device dimension is qualitatively different from conventional silicon transistors, reflecting the very different device physics of a ballistic transistor with a quasi-one-dimensional channel. The combination of gate-oxide scaling and improved control of fixed-charge density should provide the uniformity needed for large-scale integration of such novel one-dimensional transistors even at extremely scaled device dimensions.
Temperature Swings in a Hot Jupiter's Atmosphere
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2016-04-01
Weather variations in the atmosphere of a planet on a highly eccentric orbit are naturally expected to be extreme. Now, a study has directly measured the wild changes in the atmosphere of a highly eccentric hot Jupiter as it passes close to its host star.Diagram of the HD 80606 system. The inset images labeled AH show the temperature distribution of the planet at different stages as it swings around its star. [de Wit et al. 2016]Eccentric OpportunityFor a hot Jupiter a gas giant that orbits close to its host star the exoplanet HD 80606 b exhibits a fairly unusual path. Rather than having a circularized orbit, HD 80606 b travels on an extremely elliptic 111-day orbit, with an eccentricity of e ~ 0.93. Since the amount of flux HD 80606 b receives from its host varies by a factor of ~850 over the course of its orbit, it stands to reason that this planet must have extreme weather swings!Now a team of scientists led by Julien de Wit (Massachusetts Institute of Technology) has reanalyzed old observations of HD 80606 and obtained new ones using the Spitzer Space Telescope. The longer observing time and new data analysis techniques allowed the team to gain new insights into how the exoplanets atmosphere responds to changes in the stellar flux it receives during its orbit.Extreme VariationsBy measuring the infrared light coming from HD 80606, de Wit and collaborators modeled the planets temperature during 80 hours of its closest approach to its host star. This period of time included the ~20 hours in which most of the planets temperature change is expected to occur, as it approaches to a distance a mere 6 stellar radii from its host.The authors find that the layer of the atmosphere probed by Spitzer heats rapidly from 500K to 1400K (thats ~440F to a scalding 2000+F!) as the planet approaches periastron.The atmosphere then cools similarly quickly as the planet heads away from the star once more.Relative infrared brightness of HD 80606 b at 4.5 and 8 m. The dip marks where the planet passes behind the star, as viewed from Earth. [de Wit et al. 2016]Exploring an Atmospheric LayerBased on the authors models, the layer of the planets atmosphere probed by Spitzer absorbs ~20% of the radiation incident from the host star. This atmospheric layer has a ~4-hour radiative timescale, much shorter than the ~93-hour rotation period the authors estimate for HD 80606 b which means that the heat is not transported efficiently from the day side to the night side of the planet.These measurements are the first of their kind for an exoplanets atmosphere, opening a new window into our understanding of hot Jupiters. Applying the methods used here to other eccentric planets should help us to better understand the formation mechanisms and atmospheres of these extreme planets.CitationJulien de Witet al2016ApJ820L33. doi:10.3847/2041-8205/820/2/L33
Temperature control during regeneration of activated carbon fiber cloth with resistance-feedback.
Johnsen, David L; Rood, Mark J
2012-10-16
Electrothermal swing adsorption (ESA) of organic compounds from gas streams with activated carbon fiber cloth (ACFC) reduces emissions to the atmosphere and recovers feedstock for reuse. Local temperature measurement (e.g., with a thermocouple) is typically used to monitor/control adsorbent regeneration cycles. Remote electrical resistance measurement is evaluated here as an alternative to local temperature measurement. ACFC resistance that was modeled based on its physical properties was within 10.5% of the measured resistance values during electrothermal heating. Resistance control was developed based on this measured relationship and used to control temperature to within 2.3% of regeneration set-point temperatures. Isobutane-laden adsorbent was then heated with resistance control. After 2 min of heating, the temperature of the adsorbent with isobutane was 13% less than the adsorbent without isobutane. This difference decreased to 2.1% after 9 min of heating, showing desorption of isobutane. An ACFC cartridge was also heated to 175 °C for 900 cycles with its resistance and adsorption capacity values remaining within 3% and 2%, respectively. This new method to control regeneration power application based on rapid sensing of the adsorbent's resistance removes the need for direct-contact temperature sensors providing a simple, cost-efficient, and long-term regeneration technique for ESA systems.
2010-06-01
to result in lower maintenance and higher reliability compared with the commercially practiced options of pressure swing adsorption (PSA) or vacuum ...screen and the temperature displayed on the graph will decrease. The Knob is used to zoom the chart and scroll through historical values. For a list of...Friday ‐ Status: OK. Tinker AFB reported a FAL alarm occurs when the compressor isn’t pumping oxygen. The FAL alarm terminates when the
Yang, Wen-Wen; Liu, Ya-Chen; Lu, Lee-Chang; Chang, Hsiao-Yun; Chou, Paul Pei-Hsi; Liu, Chiang
2013-12-01
Compared with regulation-weight baseballs, lightweight baseballs generate lower torque on the shoulder and elbow joints without altering the pitching movement and timing. This study investigates the throwing accuracy, throwing velocity, arm swing velocity, and maximum shoulder external rotation (MSER) of adolescent players after 10 weeks of pitching training with appropriate lightweight baseballs. We assigned 24 adolescent players to a lightweight baseball group (group L) and a regulation-weight baseball group (group R) based on their pretraining throwing velocity. Both groups received pitching training 3 times per week for 10 weeks with 4.4- and 5-oz baseballs. The players' throwing accuracy, throwing velocity, arm swing velocity, and MSER were measured from 10 maximum efforts throws using a regulation-weight baseball before and after undergoing the pitching training. The results showed that the players in group L significantly increased their throwing velocity and arm swing velocity (p < 0.05) after 10 weeks of pitching training with the 4.4-oz baseball, whereas group R did not (p > 0.05). Furthermore, the percentage change in the throwing velocity and arm swing velocity of group L was significantly superior to that of group R (p < 0.05). Thus, we concluded that the 10 weeks of pitching training with an appropriate lightweight baseball substantially enhanced the arm swing velocity and throwing velocity of the adolescent baseball players. These findings suggest that using a lightweight baseball, which can reduce the risk of injury without altering pitching patterns, has positive training effects on players in the rapid physical growth and technique development stage.
Self-Reported Recovery from 2-Week 12-Hour Shift Work Schedules: A 14-Day Follow-Up.
Merkus, Suzanne L; Holte, Kari Anne; Huysmans, Maaike A; van de Ven, Peter M; van Mechelen, Willem; van der Beek, Allard J
2015-09-01
Recovery from fatigue is important in maintaining night workers' health. This study compared the course of self-reported recovery after 2-week 12-hour schedules consisting of either night shifts or swing shifts (i.e., 7 night shifts followed by 7 day shifts) to such schedules consisting of only day work. Sixty-one male offshore employees-20 night workers, 16 swing shift workers, and 25 day workers-rated six questions on fatigue (sleep quality, feeling rested, physical and mental fatigue, and energy levels; scale 1-11) for 14 days after an offshore tour. After the two night-work schedules, differences on the 1(st) day (main effects) and differences during the follow-up (interaction effects) were compared to day work with generalized estimating equations analysis. After adjustment for confounders, significant main effects were found for sleep quality for night workers (1.41, 95% confidence interval 1.05-1.89) and swing shift workers (1.42, 95% confidence interval 1.03-1.94) when compared to day workers; their interaction terms were not statistically significant. For the remaining fatigue outcomes, no statistically significant main or interaction effects were found. After 2-week 12-hour night and swing shifts, only the course for sleep quality differed from that of day work. Sleep quality was poorer for night and swing shift workers on the 1(st) day off and remained poorer for the 14-day follow-up. This showed that while working at night had no effect on feeling rested, tiredness, and energy levels, it had a relatively long-lasting effect on sleep quality.
Swing limb mechanics and minimum toe clearance in people with knee osteoarthritis.
Levinger, Pazit; Lai, Daniel T H; Menz, Hylton B; Morrow, Adam D; Feller, Julian A; Bartlett, John R; Bergman, Neil R; Begg, Rezaul
2012-02-01
Knee osteoarthritis (OA) has been shown to be a risk factor for falls. Reductions in foot clearance during the swing phase of walking can cause a trip and potentially lead to a fall. This study examined the swing phase mechanics of people with and without knee OA during walking. Minimum toe clearance (MTC) height, joint angles at the time of MTC and the influence of the angular changes of the hip, knee and ankle of the swing leg on foot clearance using sensitivity analysis were investigated in 50 knee OA participants and 28 age-matched asymptomatic controls. Although both groups had a similar MTC height (controls: 12.8±6.7 mm, knee OA: 13.4±7.0 mm), the knee OA group used a different strategy to achieve the same foot clearance, as evidenced by greater knee flexion (52.5±5.3° vs 49.4±4.8°, p=0.007), greater hip abduction (-3.6±3.3° vs -1.8±3.3°, p=0.03) and less ankle adduction (2.8±1.9° vs 4.2±2.1°, p=0.01). MTC height was comparable between the groups, however a different swing phase mechanism was used by the knee OA. Although adequate MTC is an important component of safe locomotion, it does not appear to be impaired in people with knee OA. Other factors, such as inadequate responses to postural perturbation, may be responsible for falls in this group. Copyright © 2011 Elsevier B.V. All rights reserved.
HAND TRUCK FOR HANDLING EQUIPMENT
King, D.W.
1959-02-24
A truck is described for the handling of large and relatively heavy pieces of equipment and particularly for the handling of ion source units for use in calutrons. The truck includes a chassis and a frame pivoted to the chassis so as to be operable to swing in the manner of a boom. The frame has spaced members so arranged that the device to be handled can be suspended between or passed between these spaced members and also rotated with respect to the frame when the device is secured to the spaced members.
2009-06-20
CAPE CANAVERAL, Fla. – The slings from a large crane swing the detached orbiter access arm, which ends in the White Room, away from the fixed service structure, or FSS, on Launch Pad 39B at NASA's Kennedy Space Center in Florida. The White Room provided entry into space shuttles that were on the pad. The arm is being removed from the FSS for the pad's conversion as launch site for the Constellation Program's Ares I-X. The launch of the Ares I-X flight test is targeted for August 2009. Photo credit: NASA/Kim Shiflett
Positioning Mechanism For Hoisting
NASA Technical Reports Server (NTRS)
Marlin, John D., III; Moore, Barry J.; Myers, Robert I.
1992-01-01
Mechanism positions large, heavy objects in container for lifting out by hoist, crane, or winch. Handles objects gently and ensures they are lifted cleanly away in vertical direction without bumping container. Developed for lifting offset pieces of solid-propellant core out of rocket motor through its propellant port. Similar specialized mechanisms can be developed to lift other specially shaped, specially contained heavy objects. Track in base of mechanism guides each trunnion and piece to which attached to middle as hydraulic rods extend. When mechanism lifted, tilted pieces swing inward and come to rest on energy-absorbing paddle.
NASA Technical Reports Server (NTRS)
Royrvik, O.
1983-01-01
It has been suggested that the spaced antenna drift (SAD) technique could be successfully used by VHF radars and that it would be superior to a Doppler-beam-swinging (DBS) technique because it would take advantage of the aspect sensitivity of the scattered signal, and might also benefit from returns from single meteors. It appears, however, that the technique suffers from several limitations. On the basis of one SAD experiment performed at the very large Jicamarca radar, it is concluded that the SAD technique can be compared in accuracy to the DBS technique only if small antenna dimensions are used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judd, Stephen; Dallmann, Nicholas; Seitz, Daniel
A modular space vehicle chassis may facilitate convenient access to internal components of the space vehicle. Each module may be removable from the others such that each module may be worked on individually. Multiple panels of at least one of the modules may swing open or otherwise be removable, exposing large portions of the internal components of the space vehicle. Such chassis architectures may reduce the time required for and difficulty of performing maintenance or modifications, may allow multiple space vehicles to take advantage of a common chassis design, and may further allow for highly customizable space vehicles.
Frame Matching and [Delta]PTED: A Framework for Teaching Swing and Blues Dance Partner Connection
ERIC Educational Resources Information Center
DeMers, Joseph Daniel
2013-01-01
Frame Matching is a codified theory of partner-dance connection. It establishes a framework for breaking down and teaching Swing and Blues dance connection. It is the act of creating, maintaining, or changing tension between partners with posture and tone, in order to lead and follow energy and direction. Frame Matching is explained in terms of…
ERIC Educational Resources Information Center
Inouye, Martha; Houseal, Ana
2018-01-01
Anyone who has spent decades in public education is aware of the pendulum swing of ideas, strategies, and policies that can cause drastic changes. Since the 1980s, inclusion of critical thinking development in classrooms has sharply declined, given accountability mandates and legislation such as No Child Left Behind. A potential reawakening to…