Sample records for large-scale distributed mammogram

  1. A new idea for visualization of lesions distribution in mammogram based on CPD registration method.

    PubMed

    Pan, Xiaoguang; Qi, Buer; Yu, Hongfei; Wei, Haiping; Kang, Yan

    2017-07-20

    Mammography is currently the most effective technique for breast cancer. Lesions distribution can provide support for clinical diagnosis and epidemiological studies. We presented a new idea to help radiologists study breast lesions distribution conveniently. We also developed an automatic tool based on this idea which could show visualization of lesions distribution in a standard mammogram. Firstly, establishing a lesion database to study; then, extracting breast contours and match different women's mammograms to a standard mammogram; finally, showing the lesion distribution in the standard mammogram, and providing the distribution statistics. The crucial process of developing this tool was matching different women's mammograms correctly. We used a hybrid breast contour extraction method combined with coherent point drift method to match different women's mammograms. We tested our automatic tool by four mass datasets of 641 images. The distribution results shown by the tool were consistent with the results counted according to their reports and mammograms by manual. We also discussed the registration error that was less than 3.3 mm in average distance. The new idea is effective and the automatic tool can provide lesions distribution results which are consistent with radiologists simply and conveniently.

  2. Three-Class Mammogram Classification Based on Descriptive CNN Features

    PubMed Central

    Zhang, Qianni; Jadoon, Adeel

    2017-01-01

    In this paper, a novel classification technique for large data set of mammograms using a deep learning method is proposed. The proposed model targets a three-class classification study (normal, malignant, and benign cases). In our model we have presented two methods, namely, convolutional neural network-discrete wavelet (CNN-DW) and convolutional neural network-curvelet transform (CNN-CT). An augmented data set is generated by using mammogram patches. To enhance the contrast of mammogram images, the data set is filtered by contrast limited adaptive histogram equalization (CLAHE). In the CNN-DW method, enhanced mammogram images are decomposed as its four subbands by means of two-dimensional discrete wavelet transform (2D-DWT), while in the second method discrete curvelet transform (DCT) is used. In both methods, dense scale invariant feature (DSIFT) for all subbands is extracted. Input data matrix containing these subband features of all the mammogram patches is created that is processed as input to convolutional neural network (CNN). Softmax layer and support vector machine (SVM) layer are used to train CNN for classification. Proposed methods have been compared with existing methods in terms of accuracy rate, error rate, and various validation assessment measures. CNN-DW and CNN-CT have achieved accuracy rate of 81.83% and 83.74%, respectively. Simulation results clearly validate the significance and impact of our proposed model as compared to other well-known existing techniques. PMID:28191461

  3. Three-Class Mammogram Classification Based on Descriptive CNN Features.

    PubMed

    Jadoon, M Mohsin; Zhang, Qianni; Haq, Ihsan Ul; Butt, Sharjeel; Jadoon, Adeel

    2017-01-01

    In this paper, a novel classification technique for large data set of mammograms using a deep learning method is proposed. The proposed model targets a three-class classification study (normal, malignant, and benign cases). In our model we have presented two methods, namely, convolutional neural network-discrete wavelet (CNN-DW) and convolutional neural network-curvelet transform (CNN-CT). An augmented data set is generated by using mammogram patches. To enhance the contrast of mammogram images, the data set is filtered by contrast limited adaptive histogram equalization (CLAHE). In the CNN-DW method, enhanced mammogram images are decomposed as its four subbands by means of two-dimensional discrete wavelet transform (2D-DWT), while in the second method discrete curvelet transform (DCT) is used. In both methods, dense scale invariant feature (DSIFT) for all subbands is extracted. Input data matrix containing these subband features of all the mammogram patches is created that is processed as input to convolutional neural network (CNN). Softmax layer and support vector machine (SVM) layer are used to train CNN for classification. Proposed methods have been compared with existing methods in terms of accuracy rate, error rate, and various validation assessment measures. CNN-DW and CNN-CT have achieved accuracy rate of 81.83% and 83.74%, respectively. Simulation results clearly validate the significance and impact of our proposed model as compared to other well-known existing techniques.

  4. Sampling probability distributions of lesions in mammograms

    NASA Astrophysics Data System (ADS)

    Looney, P.; Warren, L. M.; Dance, D. R.; Young, K. C.

    2015-03-01

    One approach to image perception studies in mammography using virtual clinical trials involves the insertion of simulated lesions into normal mammograms. To facilitate this, a method has been developed that allows for sampling of lesion positions across the cranio-caudal and medio-lateral radiographic projections in accordance with measured distributions of real lesion locations. 6825 mammograms from our mammography image database were segmented to find the breast outline. The outlines were averaged and smoothed to produce an average outline for each laterality and radiographic projection. Lesions in 3304 mammograms with malignant findings were mapped on to a standardised breast image corresponding to the average breast outline using piecewise affine transforms. A four dimensional probability distribution function was found from the lesion locations in the cranio-caudal and medio-lateral radiographic projections for calcification and noncalcification lesions. Lesion locations sampled from this probability distribution function were mapped on to individual mammograms using a piecewise affine transform which transforms the average outline to the outline of the breast in the mammogram. The four dimensional probability distribution function was validated by comparing it to the two dimensional distributions found by considering each radiographic projection and laterality independently. The correlation of the location of the lesions sampled from the four dimensional probability distribution function across radiographic projections was shown to match the correlation of the locations of the original mapped lesion locations. The current system has been implemented as a web-service on a server using the Python Django framework. The server performs the sampling, performs the mapping and returns the results in a javascript object notation format.

  5. [Estimated mammogram coverage in Goiás State, Brazil].

    PubMed

    Corrêa, Rosangela da Silveira; Freitas-Júnior, Ruffo; Peixoto, João Emílio; Rodrigues, Danielle Cristina Netto; Lemos, Maria Eugênia da Fonseca; Marins, Lucy Aparecida Parreira; Silveira, Erika Aparecida da

    2011-09-01

    This cross-sectional study aimed to estimate mammogram coverage in the State of Goiás, Brazil, describing the supply, demand, and variations in different age groups, evaluating 98 mammography services as observational units. We estimated the mammogram rates by age group and type of health service, as well as the number of tests required to cover 70% and 100% of the target population. We assessed the association between mammograms, geographical distribution of mammography machines, type of service, and age group. Full coverage estimates, considering 100% of women in the 40-69 and 50-69-year age brackets, were 61% and 66%, of which the Brazilian Unified National Health System provided 13% and 14%, respectively. To achieve 70% coverage, 43,424 additional mammograms would be needed. All the associations showed statistically significant differences (p < 0.001). We conclude that mammogram coverage is unevenly distributed in the State of Goiás and that fewer tests are performed than required.

  6. Clustering microcalcifications techniques in digital mammograms

    NASA Astrophysics Data System (ADS)

    Díaz, Claudia. C.; Bosco, Paolo; Cerello, Piergiorgio

    2008-11-01

    Breast cancer has become a serious public health problem around the world. However, this pathology can be treated if it is detected in early stages. This task is achieved by a radiologist, who should read a large amount of mammograms per day, either for a screening or diagnostic purpose in mammography. However human factors could affect the diagnosis. Computer Aided Detection is an automatic system, which can help to specialists in the detection of possible signs of malignancy in mammograms. Microcalcifications play an important role in early detection, so we focused on their study. The two mammographic features that indicate the microcalcifications could be probably malignant are small size and clustered distribution. We worked with density techniques for automatic clustering, and we applied them on a mammography CAD prototype developed at INFN-Turin, Italy. An improvement of performance is achieved analyzing images from a Perugia-Assisi Hospital, in Italy.

  7. Detecting mammographically occult cancer in women with dense breasts using Radon Cumulative Distribution Transform: a preliminary analysis

    NASA Astrophysics Data System (ADS)

    Lee, Juhun; Nishikawa, Robert M.; Rohde, Gustavo K.

    2018-02-01

    We propose using novel imaging biomarkers for detecting mammographically-occult (MO) cancer in women with dense breast tissue. MO cancer indicates visually occluded, or very subtle, cancer that radiologists fail to recognize as a sign of cancer. We used the Radon Cumulative Distribution Transform (RCDT) as a novel image transformation to project the difference between left and right mammograms into a space, increasing the detectability of occult cancer. We used a dataset of 617 screening full-field digital mammograms (FFDMs) of 238 women with dense breast tissue. Among 238 women, 173 were normal with 2 - 4 consecutive screening mammograms, 552 normal mammograms in total, and the remaining 65 women had an MO cancer with a negative screening mammogram. We used Principal Component Analysis (PCA) to find representative patterns in normal mammograms in the RCDT space. We projected all mammograms to the space constructed by the first 30 eigenvectors of the RCDT of normal cases. Under 10-fold crossvalidation, we conducted quantitative feature analysis to classify normal mammograms and mammograms with MO cancer. We used receiver operating characteristic (ROC) analysis to evaluate the classifier's output using the area under the ROC curve (AUC) as the figure of merit. Four eigenvectors were selected via a feature selection method. The mean and standard deviation of the AUC of the trained classifier on the test set were 0.74 and 0.08, respectively. In conclusion, we utilized imaging biomarkers to highlight differences between left and right mammograms to detect MO cancer using novel imaging transformation.

  8. Global detection approach for clustered microcalcifications in mammograms using a deep learning network.

    PubMed

    Wang, Juan; Nishikawa, Robert M; Yang, Yongyi

    2017-04-01

    In computerized detection of clustered microcalcifications (MCs) from mammograms, the traditional approach is to apply a pattern detector to locate the presence of individual MCs, which are subsequently grouped into clusters. Such an approach is often susceptible to the occurrence of false positives (FPs) caused by local image patterns that resemble MCs. We investigate the feasibility of a direct detection approach to determining whether an image region contains clustered MCs or not. Toward this goal, we develop a deep convolutional neural network (CNN) as the classifier model to which the input consists of a large image window ([Formula: see text] in size). The multiple layers in the CNN classifier are trained to automatically extract image features relevant to MCs at different spatial scales. In the experiments, we demonstrated this approach on a dataset consisting of both screen-film mammograms and full-field digital mammograms. We evaluated the detection performance both on classifying image regions of clustered MCs using a receiver operating characteristic (ROC) analysis and on detecting clustered MCs from full mammograms by a free-response receiver operating characteristic analysis. For comparison, we also considered a recently developed MC detector with FP suppression. In classifying image regions of clustered MCs, the CNN classifier achieved 0.971 in the area under the ROC curve, compared to 0.944 for the MC detector. In detecting clustered MCs from full mammograms, at 90% sensitivity, the CNN classifier obtained an FP rate of 0.69 clusters/image, compared to 1.17 clusters/image by the MC detector. These results indicate that using global image features can be more effective in discriminating clustered MCs from FPs caused by various sources, such as linear structures, thereby providing a more accurate detection of clustered MCs on mammograms.

  9. Multi-scales region segmentation for ROI separation in digital mammograms

    NASA Astrophysics Data System (ADS)

    Zhang, Dapeng; Zhang, Di; Li, Yue; Wang, Wei

    2017-02-01

    Mammography is currently the most effective imaging modality used by radiologists for the screening of breast cancer. Segmentation is one of the key steps in the process of developing anatomical models for calculation of safe medical dose of radiation. This paper explores the potential of the statistical region merging segmentation technique for Breast segmentation in digital mammograms. First, the mammograms are pre-processing for regions enhancement, then the enhanced images are segmented using SRM with multi scales, finally these segmentations are combined for region of interest (ROI) separation and edge detection. The proposed algorithm uses multi-scales region segmentation in order to: separate breast region from background region, region edge detection and ROIs separation. The experiments are performed using a data set of mammograms from different patients, demonstrating the validity of the proposed criterion. Results show that, the statistical region merging segmentation algorithm actually can work on the segmentation of medical image and more accurate than another methods. And the outcome shows that the technique has a great potential to become a method of choice for segmentation of mammograms.

  10. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with theirmore » gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks when compared to the previous one. Specifically, at 60%, 65%, and 70% per-mammogram sensitivity, the new CAD system achieves 0.50, 0.68, and 0.92 FP marks per mammogram, whereas at 70%, 75%, and 80% per-case sensitivity it achieves 0.37, 0.48, and 0.71 FP marks per mammogram, respectively. Conversely, at the same sensitivities, the previous CAD system reached 0.71, 0.87, and 1.15 FP marks per mammogram, and 0.57, 0.73, and 0.92 FPs per mammogram. Also, statistical significance of the difference between the two per-mammogram and per-case FROC curves is demonstrated by the p-value<0.001 returned by jackknife FROC analysis performed on the two CAD systems.« less

  11. External validation of Medicare claims codes for digital mammography and computer-aided detection.

    PubMed

    Fenton, Joshua J; Zhu, Weiwei; Balch, Steven; Smith-Bindman, Rebecca; Lindfors, Karen K; Hubbard, Rebecca A

    2012-08-01

    While Medicare claims are a potential resource for clinical mammography research or quality monitoring, the validity of key data elements remains uncertain. Claims codes for digital mammography and computer-aided detection (CAD), for example, have not been validated against a credible external reference standard. We matched Medicare mammography claims for women who received bilateral mammograms from 2003 to 2006 to corresponding mammography data from the Breast Cancer Surveillance Consortium (BCSC) registries in four U.S. states (N = 253,727 mammograms received by 120,709 women). We assessed the accuracy of the claims-based classifications of bilateral mammograms as either digital versus film and CAD versus non-CAD relative to a reference standard derived from BCSC data. Claims data correctly classified the large majority of film and digital mammograms (97.2% and 97.3%, respectively), yielding excellent agreement beyond chance (κ = 0.90). Claims data correctly classified the large majority of CAD mammograms (96.6%) but a lower percentage of non-CAD mammograms (86.7%). Agreement beyond chance remained high for CAD classification (κ = 0.83). From 2003 to 2006, the predictive values of claims-based digital and CAD classifications increased as the sample prevalences of each technology increased. Medicare claims data can accurately distinguish film and digital bilateral mammograms and mammograms conducted with and without CAD. The validity of Medicare claims data regarding film versus digital mammography and CAD suggests that these data elements can be useful in research and quality improvement. ©2012 AACR.

  12. Deep learning and non-negative matrix factorization in recognition of mammograms

    NASA Astrophysics Data System (ADS)

    Swiderski, Bartosz; Kurek, Jaroslaw; Osowski, Stanislaw; Kruk, Michal; Barhoumi, Walid

    2017-02-01

    This paper presents novel approach to the recognition of mammograms. The analyzed mammograms represent the normal and breast cancer (benign and malignant) cases. The solution applies the deep learning technique in image recognition. To obtain increased accuracy of classification the nonnegative matrix factorization and statistical self-similarity of images are applied. The images reconstructed by using these two approaches enrich the data base and thanks to this improve of quality measures of mammogram recognition (increase of accuracy, sensitivity and specificity). The results of numerical experiments performed on large DDSM data base containing more than 10000 mammograms have confirmed good accuracy of class recognition, exceeding the best results reported in the actual publications for this data base.

  13. Availability and accessibility of subsidized mammogram screening program in peninsular Malaysia: A preliminary study using travel impedance approach.

    PubMed

    Mahmud, Aidalina; Aljunid, Syed Mohamed

    2018-01-01

    Access to healthcare is essential in the pursuit of universal health coverage. Components of access are availability, accessibility (spatial and non-spatial), affordability and acceptability. Measuring spatial accessibility is common approach to evaluating access to health care. This study aimed to determine the availability and spatial accessibility of subsidised mammogram screening in Peninsular Malaysia. Availability was determined from the number and distribution of facilities. Spatial accessibility was determined using the travel impedance approach to represent the revealed access as opposed to potential access measured by other spatial measurement methods. The driving distance of return trips from the respondent's residence to the facilities was determined using a mapping application. The travel expenditure was estimated by multiplying the total travel distance by a standardised travel allowance rate, plus parking fees. Respondents in this study were 344 breast cancer patients who received treatment at 4 referral hospitals between 2015 and 2016. In terms of availability, there were at least 6 major entities which provided subsidised mammogram programs. Facilities with mammogram involved with these programs were located more densely in the central and west coast region of the Peninsula. The ratio of mammogram facility to the target population of women aged 40-74 years ranged between 1: 10,000 and 1:80,000. In terms of accessibility, of the 3.6% of the respondents had undergone mammogram screening, their mean travel distance was 53.4 km (SD = 34.5, range 8-112 km) and the mean travel expenditure was RM 38.97 (SD = 24.00, range RM7.60-78.40). Among those who did not go for mammogram screening, the estimated travel distance and expenditure had a skewed distribution with median travel distance of 22.0 km (IQR 12.0, 42.0, range 2.0-340.0) and the median travel cost of RM 17.40 (IQR 10.40, 30.00, range 3.40-240.00). Higher travel impedance was noted among those who lived in sub-urban and rural areas. In summary, availability of mammogram facilities was good in the central and west coast of the peninsula. The overall provider-to-population ratio was lower than recommended. Based on the travel impedance approach used, accessibility to subsidised mammogram screening among the respondents was good in urban areas but deprived in other areas. This study was a preliminary study with limitations. Nonetheless, the evidence suggests that actions have to be taken to improve the accessibility to opportunistic mammogram screening in Malaysia in pursuit of universal health coverage.

  14. Accurate 3D Modeling of Breast Deformation for Temporal Mammogram Registration

    DTIC Science & Technology

    2009-09-01

    U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION...MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland...Towards Registration of Temporal Mammograms by Finite Element Simulation of MR Breast Volumes”, Proceedings of SPIE Medical Imaging 2008 2. Qiu Y

  15. Using multiscale texture and density features for near-term breast cancer risk analysis

    PubMed Central

    Sun, Wenqing; Tseng, Tzu-Liang (Bill); Qian, Wei; Zhang, Jianying; Saltzstein, Edward C.; Zheng, Bin; Lure, Fleming; Yu, Hui; Zhou, Shi

    2015-01-01

    Purpose: To help improve efficacy of screening mammography by eventually establishing a new optimal personalized screening paradigm, the authors investigated the potential of using the quantitative multiscale texture and density feature analysis of digital mammograms to predict near-term breast cancer risk. Methods: The authors’ dataset includes digital mammograms acquired from 340 women. Among them, 141 were positive and 199 were negative/benign cases. The negative digital mammograms acquired from the “prior” screening examinations were used in the study. Based on the intensity value distributions, five subregions at different scales were extracted from each mammogram. Five groups of features, including density and texture features, were developed and calculated on every one of the subregions. Sequential forward floating selection was used to search for the effective combinations. Using the selected features, a support vector machine (SVM) was optimized using a tenfold validation method to predict the risk of each woman having image-detectable cancer in the next sequential mammography screening. The area under the receiver operating characteristic curve (AUC) was used as the performance assessment index. Results: From a total number of 765 features computed from multiscale subregions, an optimal feature set of 12 features was selected. Applying this feature set, a SVM classifier yielded performance of AUC = 0.729 ± 0.021. The positive predictive value was 0.657 (92 of 140) and the negative predictive value was 0.755 (151 of 200). Conclusions: The study results demonstrated a moderately high positive association between risk prediction scores generated by the quantitative multiscale mammographic image feature analysis and the actual risk of a woman having an image-detectable breast cancer in the next subsequent examinations. PMID:26127038

  16. Computer-aided diagnosis of malignant mammograms using Zernike moments and SVM.

    PubMed

    Sharma, Shubhi; Khanna, Pritee

    2015-02-01

    This work is directed toward the development of a computer-aided diagnosis (CAD) system to detect abnormalities or suspicious areas in digital mammograms and classify them as malignant or nonmalignant. Original mammogram is preprocessed to separate the breast region from its background. To work on the suspicious area of the breast, region of interest (ROI) patches of a fixed size of 128×128 are extracted from the original large-sized digital mammograms. For training, patches are extracted manually from a preprocessed mammogram. For testing, patches are extracted from a highly dense area identified by clustering technique. For all extracted patches corresponding to a mammogram, Zernike moments of different orders are computed and stored as a feature vector. A support vector machine (SVM) is used to classify extracted ROI patches. The experimental study shows that the use of Zernike moments with order 20 and SVM classifier gives better results among other studies. The proposed system is tested on Image Retrieval In Medical Application (IRMA) reference dataset and Digital Database for Screening Mammography (DDSM) mammogram database. On IRMA reference dataset, it attains 99% sensitivity and 99% specificity, and on DDSM mammogram database, it obtained 97% sensitivity and 96% specificity. To verify the applicability of Zernike moments as a fitting texture descriptor, the performance of the proposed CAD system is compared with the other well-known texture descriptors namely gray-level co-occurrence matrix (GLCM) and discrete cosine transform (DCT).

  17. Mammogram image quality as a potential contributor to disparities in breast cancer stage at diagnosis: an observational study

    PubMed Central

    2013-01-01

    Background In an ongoing study of racial/ethnic disparities in breast cancer stage at diagnosis, we consented patients to allow us to review their mammogram images, in order to examine the potential role of mammogram image quality on this disparity. Methods In a population-based study of urban breast cancer patients, a single breast imaging specialist (EC) performed a blinded review of the index mammogram that prompted diagnostic follow-up, as well as recent prior mammograms performed approximately one or two years prior to the index mammogram. Seven indicators of image quality were assessed on a five-point Likert scale, where 4 and 5 represented good and excellent quality. These included 3 technologist-associated image quality (TAIQ) indicators (positioning, compression, sharpness), and 4 machine associated image quality (MAIQ) indicators (contrast, exposure, noise and artifacts). Results are based on 494 images examined for 268 patients, including 225 prior images. Results Whereas MAIQ was generally high, TAIQ was more variable. In multivariable models of sociodemographic predictors of TAIQ, less income was associated with lower TAIQ (p < 0.05). Among prior mammograms, lower TAIQ was subsequently associated with later stage at diagnosis, even after adjusting for multiple patient and practice factors (OR = 0.80, 95% CI: 0.65, 0.99). Conclusions Considerable gains could be made in terms of increasing image quality through better positioning, compression and sharpness, gains that could impact subsequent stage at diagnosis. PMID:23621946

  18. Availability and accessibility of subsidized mammogram screening program in peninsular Malaysia: A preliminary study using travel impedance approach

    PubMed Central

    Aljunid, Syed Mohamed

    2018-01-01

    Access to healthcare is essential in the pursuit of universal health coverage. Components of access are availability, accessibility (spatial and non-spatial), affordability and acceptability. Measuring spatial accessibility is common approach to evaluating access to health care. This study aimed to determine the availability and spatial accessibility of subsidised mammogram screening in Peninsular Malaysia. Availability was determined from the number and distribution of facilities. Spatial accessibility was determined using the travel impedance approach to represent the revealed access as opposed to potential access measured by other spatial measurement methods. The driving distance of return trips from the respondent’s residence to the facilities was determined using a mapping application. The travel expenditure was estimated by multiplying the total travel distance by a standardised travel allowance rate, plus parking fees. Respondents in this study were 344 breast cancer patients who received treatment at 4 referral hospitals between 2015 and 2016. In terms of availability, there were at least 6 major entities which provided subsidised mammogram programs. Facilities with mammogram involved with these programs were located more densely in the central and west coast region of the Peninsula. The ratio of mammogram facility to the target population of women aged 40–74 years ranged between 1: 10,000 and 1:80,000. In terms of accessibility, of the 3.6% of the respondents had undergone mammogram screening, their mean travel distance was 53.4 km (SD = 34.5, range 8–112 km) and the mean travel expenditure was RM 38.97 (SD = 24.00, range RM7.60–78.40). Among those who did not go for mammogram screening, the estimated travel distance and expenditure had a skewed distribution with median travel distance of 22.0 km (IQR 12.0, 42.0, range 2.0–340.0) and the median travel cost of RM 17.40 (IQR 10.40, 30.00, range 3.40–240.00). Higher travel impedance was noted among those who lived in sub-urban and rural areas. In summary, availability of mammogram facilities was good in the central and west coast of the peninsula. The overall provider-to-population ratio was lower than recommended. Based on the travel impedance approach used, accessibility to subsidised mammogram screening among the respondents was good in urban areas but deprived in other areas. This study was a preliminary study with limitations. Nonetheless, the evidence suggests that actions have to be taken to improve the accessibility to opportunistic mammogram screening in Malaysia in pursuit of universal health coverage. PMID:29389972

  19. Theorizing the Pathways From Seeking and Scanning to Mammography Screening.

    PubMed

    Lee, Chul-Joo; Zhao, Xiaoquan; Pena-y-Lillo, Macarena

    2016-01-01

    This study combines insights from existing theories in mass communication and health communication, and builds an integrated model accounting for the mechanisms by which an individual's acquisition of mammogram-related media information becomes associated with intentions to obtain a mammogram. Our model was largely supported by a survey with a nationally representative sample of American females between the ages of 40 and 70 years. As expected, seeking and scanning mammogram-related information from the media were both positively associated with reflective integration of media health information, which in turn was positively related to behavioral attitudes and perceived normative pressures. Attitudes and normative pressures were then positively linked to the intention to get a mammogram. Based on these findings, we offer some suggestions for future research in this area.

  20. Alignment of breast cancer screening guidelines, accountability metrics, and practice patterns.

    PubMed

    Onega, Tracy; Haas, Jennifer S; Bitton, Asaf; Brackett, Charles; Weiss, Julie; Goodrich, Martha; Harris, Kimberly; Pyle, Steve; Tosteson, Anna N A

    2017-01-01

    Breast cancer screening guidelines and metrics are inconsistent with each other and may differ from breast screening practice patterns in primary care. This study measured breast cancer screening practice patterns in relation to common evidence-based guidelines and accountability metrics. Cohort study using primary data collected from a regional breast cancer screening research network between 2011 and 2014. Using information on women aged 30 to 89 years within 21 primary care practices of 2 large integrated health systems in New England, we measured the proportion of women screened overall and by age using 2 screening definition categories: any mammogram and screening mammogram. Of the 81,352 women in our cohort, 54,903 (67.5%) had at least 1 mammogram during the time period, 48,314 (59.4%) had a screening mammogram. Women aged 50 to 69 years were the highest proportion screened (82.4% any mammogram, 75% screening indication); 72.6% of women at age 40 had a screening mammogram with a median of 70% (range = 54.3%-84.8%) among the practices. Of women aged at least 75 years, 63.3% had a screening mammogram, with the median of 63.9% (range = 37.2%-78.3%) among the practices. Of women who had 2 or more mammograms, 79.5% were screened annually. Primary care practice patterns for breast cancer screening are not well aligned with some evidence-based guidelines and accountability metrics. Metrics and incentives should be designed with more uniformity and should also include shared decision making when the evidence does not clearly support one single conclusion.

  1. Analysis of classifiers performance for classification of potential microcalcification

    NASA Astrophysics Data System (ADS)

    M. N., Arun K.; Sheshadri, H. S.

    2013-07-01

    Breast cancer is a significant public health problem in the world. According to the literature early detection improve breast cancer prognosis. Mammography is a screening tool used for early detection of breast cancer. About 10-30% cases are missed during the routine check as it is difficult for the radiologists to make accurate analysis due to large amount of data. The Microcalcifications (MCs) are considered to be important signs of breast cancer. It has been reported in literature that 30% - 50% of breast cancer detected radio graphically show MCs on mammograms. Histologic examinations report 62% to 79% of breast carcinomas reveals MCs. MC are tiny, vary in size, shape, and distribution, and MC may be closely connected to surrounding tissues. There is a major challenge using the traditional classifiers in the classification of individual potential MCs as the processing of mammograms in appropriate stage generates data sets with an unequal amount of information for both classes (i.e., MC, and Not-MC). Most of the existing state-of-the-art classification approaches are well developed by assuming the underlying training set is evenly distributed. However, they are faced with a severe bias problem when the training set is highly imbalanced in distribution. This paper addresses this issue by using classifiers which handle the imbalanced data sets. In this paper, we also compare the performance of classifiers which are used in the classification of potential MC.

  2. Computer-Assisted Visual Search/Decision Aids as a Training Tool for Mammography

    DTIC Science & Technology

    1999-07-01

    display of a digital mammogram that compensates for the display brightness, the ambient light and the useful range of pixel intensities in the image...described here extends the work of Liu and Nodine (7) to include adjusting the gray-scale transform for ambient illumination and adjusting the mammogram...visible" disk in each band. The observer’s responses are affected by the display contrast and the ambient room lighting. The contrast of each indicated

  3. Automatic classification for mammogram backgrounds based on bi-rads complexity definition and on a multi content analysis framework

    NASA Astrophysics Data System (ADS)

    Wu, Jie; Besnehard, Quentin; Marchessoux, Cédric

    2011-03-01

    Clinical studies for the validation of new medical imaging devices require hundreds of images. An important step in creating and tuning the study protocol is the classification of images into "difficult" and "easy" cases. This consists of classifying the image based on features like the complexity of the background, the visibility of the disease (lesions). Therefore, an automatic medical background classification tool for mammograms would help for such clinical studies. This classification tool is based on a multi-content analysis framework (MCA) which was firstly developed to recognize image content of computer screen shots. With the implementation of new texture features and a defined breast density scale, the MCA framework is able to automatically classify digital mammograms with a satisfying accuracy. BI-RADS (Breast Imaging Reporting Data System) density scale is used for grouping the mammograms, which standardizes the mammography reporting terminology and assessment and recommendation categories. Selected features are input into a decision tree classification scheme in MCA framework, which is the so called "weak classifier" (any classifier with a global error rate below 50%). With the AdaBoost iteration algorithm, these "weak classifiers" are combined into a "strong classifier" (a classifier with a low global error rate) for classifying one category. The results of classification for one "strong classifier" show the good accuracy with the high true positive rates. For the four categories the results are: TP=90.38%, TN=67.88%, FP=32.12% and FN =9.62%.

  4. Breast density characterization using texton distributions.

    PubMed

    Petroudi, Styliani; Brady, Michael

    2011-01-01

    Breast density has been shown to be one of the most significant risks for developing breast cancer, with women with dense breasts at four to six times higher risk. The Breast Imaging Reporting and Data System (BI-RADS) has a four class classification scheme that describes the different breast densities. However, there is great inter and intra observer variability among clinicians in reporting a mammogram's density class. This work presents a novel texture classification method and its application for the development of a completely automated breast density classification system. The new method represents the mammogram using textons, which can be thought of as the building blocks of texture under the operational definition of Leung and Malik as clustered filter responses. The new proposed method characterizes the mammographic appearance of the different density patterns by evaluating the texton spatial dependence matrix (TDSM) in the breast region's corresponding texton map. The TSDM is a texture model that captures both statistical and structural texture characteristics. The normalized TSDM matrices are evaluated for mammograms from the different density classes and corresponding texture models are established. Classification is achieved using a chi-square distance measure. The fully automated TSDM breast density classification method is quantitatively evaluated on mammograms from all density classes from the Oxford Mammogram Database. The incorporation of texton spatial dependencies allows for classification accuracy reaching over 82%. The breast density classification accuracy is better using texton TSDM compared to simple texton histograms.

  5. Transient Fourier holography with bacteriorhodopsin films for breast cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Rao, Devulapalli; Kothapalli, Sri-Rajasekar; Wu, Pengfei; Yelleswarapu, Chandra

    X-ray mammography is the current gold standard for breast cancer screening. Microcalcifications and other features which are helpful to the radiologist for early diagnostics are often buried in the noise generated by the surrounding dense tissue. So image processing techniques are required to enhance these important features to improve the sensitivity of detection. An innovative technique is demonstrated for recording a hologram of the mammogram. It is recorded on a thin polymer film of Bacteriorhodopsin (bR) as photo induced isomerization grating containing the interference pattern between the object beam containing the Fourier spatial frequency components of the mammogram and a reference beam. The hologram contains all the enhanced features of the mammogram. A significant innovation of the technique is that the enhanced components in the processed image can be viewed by the radiologist in time scale. A technician can record the movie and when the radiologist looks at the movie at his convenience, freezing the frame as and when desired, he would see the microcalcifications as the brightest and last long in time. He would also observe lesions with intensity decreasing as their size increases. The same bR film can be used repeatedly for recording holograms with different mammograms. The technique is versatile and a different frequency band can be chosen to be optimized by changing the reference beam intensity. The experimental arrangement can be used for mammograms in screen film or digital format.

  6. Automated selection of BI-RADS lesion descriptors for reporting calcifications in mammograms

    NASA Astrophysics Data System (ADS)

    Paquerault, Sophie; Jiang, Yulei; Nishikawa, Robert M.; Schmidt, Robert A.; D'Orsi, Carl J.; Vyborny, Carl J.; Newstead, Gillian M.

    2003-05-01

    We are developing an automated computer technique to describe calcifications in mammograms according to the BI-RADS lexicon. We evaluated this technique by its agreement with radiologists' description of the same lesions. Three expert mammographers reviewed our database of 90 cases of digitized mammograms containing clustered microcalcifications and described the calcifications according to BI-RADS. In our study, the radiologists used only 4 of the 5 calcification distribution descriptors and 5 of the 14 calcification morphology descriptors contained in BI-RADS. Our computer technique was therefore designed specifically for these 4 calcification distribution descriptors and 5 calcification morphology descriptors. For calcification distribution, 4 linear discriminant analysis (LDA) classifiers were developed using 5 computer-extracted features to produce scores of how well each descriptor describes a cluster. Similarly, for calcification morphology, 5 LDAs were designed using 10 computer-extracted features. We trained the LDAs using only the BI-RADS data reported by the first radiologist and compared the computer output to the descriptor data reported by all 3 radiologists (for the first radiologist, the leave-one-out method was used). The computer output consisted of the best calcification distribution descriptor and the best 2 calcification morphology descriptors. The results of the comparison with the data from each radiologist, respectively, were: for calcification distribution, percent agreement, 74%, 66%, and 73%, kappa value, 0.44, 0.36, and 0.46; for calcification morphology, percent agreement, 83%, 77%, and 57%, kappa value, 0.78, 0.70, and 0.44. These results indicate that the proposed computer technique can select BI-RADS descriptors in good agreement with radiologists.

  7. Psychological distress in U.S. women who have experienced false-positive mammograms.

    PubMed

    Jatoi, Ismail; Zhu, Kangmin; Shah, Mona; Lawrence, William

    2006-11-01

    In the United States, approximately 10.7% of all screening mammograms lead to a false-positive result, but the overall impact of false-positives on psychological well-being is poorly understood. Data were analyzed from the 2000 U.S. National Health Interview Survey (NHIS), the most recent national survey that included a cancer control module. Study subjects were 9,755 women who ever had a mammogram, of which 1,450 had experienced a false-positive result. Psychological distress was assessed using the validated K6 questionnaire and logistic regression was used to discern any association with previous false-positive mammograms. In a multivariate analysis, women who had indicated a previous false-positive mammogram were more likely to report feeling sad (OR = 1.18, 95% CI, 1.03-1.35), restless (OR = 1.23, 95% CI, 1.08-1.40), worthless (OR = 1.27, 95% CI, 1.04-1.54), and finding that everything was an effort (OR = 1.27, 95% CI, 1.10-1.47). These women were also more likely to have seen a mental health professional in the 12 months preceding the survey (OR = 1.28, 95% CI, 1.03-1.58) and had a higher composite score on all items of the K6 scale (P < 0.0001), a reflection of increased psychological distress. Analyses by age and race revealed that, among women who had experienced false-positives, younger women were more likely to feel that everything was an effort, and blacks were more likely to feel restless. In a random sampling of the U.S. population, women who had previously experienced false-positive mammograms were more likely to report symptoms of anxiety and depression.

  8. Psychological distress, social withdrawal, and coping following receipt of an abnormal mammogram among different ethnicities: a mediation model.

    PubMed

    Molina, Yamile; Beresford, Shirley A A; Espinoza, Noah; Thompson, Beti

    2014-09-01

    To explore ethnic differences in psychological distress and social withdrawal after receiving an abnormal mammogram result and to assess if coping strategies mediate ethnic differences. Descriptive correlational. Two urban mobile mammography units and a rural community hospital in the state of Washington. 41 Latina and 41 non-Latina Caucasian (NLC) women who had received an abnormal mammogram result. Women completed standard sociodemographic questions, Impact of Event Scale-Revised, the social dimension of the Psychological Consequences Questionnaire, and the Brief COPE. Ethnicity, psychological distress, social withdrawal, and coping. Latinas experienced greater psychological distress and social withdrawal compared to NLC counterparts. Denial as a coping strategy mediated ethnic differences in psychological distress. Religious coping mediated ethnic differences in social withdrawal. Larger population-based studies are necessary to understand how ethnic differences in coping strategies can influence psychological outcomes. This is an important finding that warrants additional study among women who are and are not diagnosed with breast cancer following an abnormal mammogram. Nurses may be able to work with Latina patients to diminish denial coping and consequent distress. Nurses may be particularly effective, given cultural values concerning strong interpersonal relationships and respect for authority figures.

  9. Summary measures of agreement and association between many raters' ordinal classifications.

    PubMed

    Mitani, Aya A; Freer, Phoebe E; Nelson, Kerrie P

    2017-10-01

    Interpretation of screening tests such as mammograms usually require a radiologist's subjective visual assessment of images, often resulting in substantial discrepancies between radiologists' classifications of subjects' test results. In clinical screening studies to assess the strength of agreement between experts, multiple raters are often recruited to assess subjects' test results using an ordinal classification scale. However, using traditional measures of agreement in some studies is challenging because of the presence of many raters, the use of an ordinal classification scale, and unbalanced data. We assess and compare the performances of existing measures of agreement and association as well as a newly developed model-based measure of agreement to three large-scale clinical screening studies involving many raters' ordinal classifications. We also conduct a simulation study to demonstrate the key properties of the summary measures. The assessment of agreement and association varied according to the choice of summary measure. Some measures were influenced by the underlying prevalence of disease and raters' marginal distributions and/or were limited in use to balanced data sets where every rater classifies every subject. Our simulation study indicated that popular measures of agreement and association are prone to underlying disease prevalence. Model-based measures provide a flexible approach for calculating agreement and association and are robust to missing and unbalanced data as well as the underlying disease prevalence. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. SU-E-I-58: Objective Models of Breast Shape Undergoing Mammography and Tomosynthesis Using Principal Component Analysis.

    PubMed

    Feng, Ssj; Sechopoulos, I

    2012-06-01

    To develop an objective model of the shape of the compressed breast undergoing mammographic or tomosynthesis acquisition. Automated thresholding and edge detection was performed on 984 anonymized digital mammograms (492 craniocaudal (CC) view mammograms and 492 medial lateral oblique (MLO) view mammograms), to extract the edge of each breast. Principal Component Analysis (PCA) was performed on these edge vectors to identify a limited set of parameters and eigenvectors that. These parameters and eigenvectors comprise a model that can be used to describe the breast shapes present in acquired mammograms and to generate realistic models of breasts undergoing acquisition. Sample breast shapes were then generated from this model and evaluated. The mammograms in the database were previously acquired for a separate study and authorized for use in further research. The PCA successfully identified two principal components and their corresponding eigenvectors, forming the basis for the breast shape model. The simulated breast shapes generated from the model are reasonable approximations of clinically acquired mammograms. Using PCA, we have obtained models of the compressed breast undergoing mammographic or tomosynthesis acquisition based on objective analysis of a large image database. Up to now, the breast in the CC view has been approximated as a semi-circular tube, while there has been no objectively-obtained model for the MLO view breast shape. Such models can be used for various breast imaging research applications, such as x-ray scatter estimation and correction, dosimetry estimates, and computer-aided detection and diagnosis. © 2012 American Association of Physicists in Medicine.

  11. Dense Breasts

    MedlinePlus

    ... fatty tissue. On a mammogram, fatty tissue appears dark (radio-lucent) and the glandular and connective tissues ... white on mammography) and non-dense fatty tissue (dark on mammography) using a visual scale and assign ...

  12. Mammogram registration using the Cauchy-Navier spline

    NASA Astrophysics Data System (ADS)

    Wirth, Michael A.; Choi, Christopher

    2001-07-01

    The process of comparative analysis involves inspecting mammograms for characteristic signs of potential cancer by comparing various analogous mammograms. Factors such as the deformable behavior of the breast, changes in breast positioning, and the amount/geometry of compression may contribute to spatial differences between corresponding structures in corresponding mammograms, thereby significantly complicating comparative analysis. Mammogram registration is a process whereby spatial differences between mammograms can be reduced. Presented in this paper is a nonrigid approach to matching corresponding mammograms based on a physical registration model. Many of the earliest approaches to mammogram registration used spatial transformations which were innately rigid or affine in nature. More recently algorithms have incorporated radial basis functions such as the Thin-Plate Spline to match mammograms. The approach presented here focuses on the use of the Cauchy-Navier Spline, a deformable registration model which offers approximate nonrigid registration. The utility of the Cauchy-Navier Spline is illustrated by matching both temporal and bilateral mammograms.

  13. Large Subpectoral Lipoma on Screening Mammography

    PubMed Central

    Su, Andres; Margolies, Laurie

    2017-01-01

    A 61 year-old woman presenting for bilateral screening mammogram was found to have an oval fat-density mass in the posterior right breast, partially visualized, with anterior displacement and thinning of the pectoralis major muscle. This mass was found on CT and MRI correlation to represent a large fat-containing mass, likely a lipoma, deep to the pectoralis major. On subsequent screening mammograms, the visualized portion of the mass remained stable. Subpectoral lipomas and intramuscular lipomas within the pectoralis major are rare, and their appearance on mammography may not be familiar to most radiologists. A review of the literature and a discussion of their appearance on multiple imaging modalities is provided. PMID:29299106

  14. Use of prior mammograms in the transition to digital mammography: a performance and cost analysis.

    PubMed

    Taylor-Phillips, S; Wallis, M G; Duncan, A; Gale, A G

    2012-01-01

    Breast screening in Europe is gradually changing from film to digital imaging and reporting of cases. In the transition period prior mammograms (from the preceding screening round) are films thereby potentially causing difficulties in comparison to current digital mammograms. To examine this breast screening performance was measured at a digital mammography workstation with prior mammograms displayed in different formats, and the associated costs calculated. 160 selected difficult cases (41% malignant) were read by eight UK qualified mammography readers in three conditions: with film prior mammograms; with digitised prior mammograms; or without prior mammograms. Lesion location and probability of malignancy were recorded, alongside a decision of whether to recall each case for further tests. JAFROC analysis showed a difference between conditions (p=.006); performance with prior mammograms in either film or digitised formats was superior to that without prior mammograms (p<.05). There was no difference in the performance when the prior mammograms were presented in film or digitised form. The number of benign or normal cases recalled was 26% higher without prior mammograms than with digitised or film prior mammograms (p<.05). This would correspond to an increase in recall rate at the study hospital from 4.3% to 5.5% with no associated increase in cancer detection rate. The cost of this increase was estimated to be £11,581 (€13,666) per 10,000 women screened, which is higher than the cost of digitised (£11,114/€13,115), or film display (£6451/€7612) of the prior mammograms. It is recommended that, where available, prior mammograms are used in the transition to digital breast screening. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  15. Multiplexed wavelet transform technique for detection of microcalcification in digitized mammograms.

    PubMed

    Mini, M G; Devassia, V P; Thomas, Tessamma

    2004-12-01

    Wavelet transform (WT) is a potential tool for the detection of microcalcifications, an early sign of breast cancer. This article describes the implementation and evaluates the performance of two novel WT-based schemes for the automatic detection of clustered microcalcifications in digitized mammograms. Employing a one-dimensional WT technique that utilizes the pseudo-periodicity property of image sequences, the proposed algorithms achieve high detection efficiency and low processing memory requirements. The detection is achieved from the parent-child relationship between the zero-crossings [Marr-Hildreth (M-H) detector] /local extrema (Canny detector) of the WT coefficients at different levels of decomposition. The detected pixels are weighted before the inverse transform is computed, and they are segmented by simple global gray level thresholding. Both detectors produce 95% detection sensitivity, even though there are more false positives for the M-H detector. The M-H detector preserves the shape information and provides better detection sensitivity for mammograms containing widely distributed calcifications.

  16. Multiscale wavelet representations for mammographic feature analysis

    NASA Astrophysics Data System (ADS)

    Laine, Andrew F.; Song, Shuwu

    1992-12-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet coefficients, enhanced by linear, exponential and constant weight functions localized in scale space. By improving the visualization of breast pathology we can improve the changes of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  17. Mammographic texture synthesis using genetic programming and clustered lumpy background

    NASA Astrophysics Data System (ADS)

    Castella, Cyril; Kinkel, Karen; Descombes, François; Eckstein, Miguel P.; Sottas, Pierre-Edouard; Verdun, Francis R.; Bochud, François O.

    2006-03-01

    In this work we investigated the digital synthesis of images which mimic real textures observed in mammograms. Such images could be produced in an unlimited number with tunable statistical properties in order to study human performance and model observer performance in perception experiments. We used the previously developed clustered lumpy background (CLB) technique and optimized its parameters with a genetic algorithm (GA). In order to maximize the realism of the textures, we combined the GA objective approach with psychophysical experiments involving the judgments of radiologists. Thirty-six statistical features were computed and averaged, over 1000 real mammograms regions of interest. The same features were measured for the synthetic textures, and the Mahalanobis distance was used to quantify the similarity of the features between the real and synthetic textures. The similarity, as measured by the Mahalanobis distance, was used as GA fitness function for evolving the free CLB parameters. In the psychophysical approach, experienced radiologists were asked to qualify the realism of synthetic images by considering typical structures that are expected to be found on real mammograms: glandular and fatty areas, and fiber crossings. Results show that CLB images found via optimization with GA are significantly closer to real mammograms than previously published images. Moreover, the psychophysical experiments confirm that all the above mentioned structures are reproduced well on the generated images. This means that we can generate an arbitrary large database of textures mimicking mammograms with traceable statistical properties.

  18. Locally adaptive decision in detection of clustered microcalcifications in mammograms.

    PubMed

    Sainz de Cea, María V; Nishikawa, Robert M; Yang, Yongyi

    2018-02-15

    In computer-aided detection or diagnosis of clustered microcalcifications (MCs) in mammograms, the performance often suffers from not only the presence of false positives (FPs) among the detected individual MCs but also large variability in detection accuracy among different cases. To address this issue, we investigate a locally adaptive decision scheme in MC detection by exploiting the noise characteristics in a lesion area. Instead of developing a new MC detector, we propose a decision scheme on how to best decide whether a detected object is an MC or not in the detector output. We formulate the individual MCs as statistical outliers compared to the many noisy detections in a lesion area so as to account for the local image characteristics. To identify the MCs, we first consider a parametric method for outlier detection, the Mahalanobis distance detector, which is based on a multi-dimensional Gaussian distribution on the noisy detections. We also consider a non-parametric method which is based on a stochastic neighbor graph model of the detected objects. We demonstrated the proposed decision approach with two existing MC detectors on a set of 188 full-field digital mammograms (95 cases). The results, evaluated using free response operating characteristic (FROC) analysis, showed a significant improvement in detection accuracy by the proposed outlier decision approach over traditional thresholding (the partial area under the FROC curve increased from 3.95 to 4.25, p-value  <10 -4 ). There was also a reduction in case-to-case variability in detected FPs at a given sensitivity level. The proposed adaptive decision approach could not only reduce the number of FPs in detected MCs but also improve case-to-case consistency in detection.

  19. Locally adaptive decision in detection of clustered microcalcifications in mammograms

    NASA Astrophysics Data System (ADS)

    Sainz de Cea, María V.; Nishikawa, Robert M.; Yang, Yongyi

    2018-02-01

    In computer-aided detection or diagnosis of clustered microcalcifications (MCs) in mammograms, the performance often suffers from not only the presence of false positives (FPs) among the detected individual MCs but also large variability in detection accuracy among different cases. To address this issue, we investigate a locally adaptive decision scheme in MC detection by exploiting the noise characteristics in a lesion area. Instead of developing a new MC detector, we propose a decision scheme on how to best decide whether a detected object is an MC or not in the detector output. We formulate the individual MCs as statistical outliers compared to the many noisy detections in a lesion area so as to account for the local image characteristics. To identify the MCs, we first consider a parametric method for outlier detection, the Mahalanobis distance detector, which is based on a multi-dimensional Gaussian distribution on the noisy detections. We also consider a non-parametric method which is based on a stochastic neighbor graph model of the detected objects. We demonstrated the proposed decision approach with two existing MC detectors on a set of 188 full-field digital mammograms (95 cases). The results, evaluated using free response operating characteristic (FROC) analysis, showed a significant improvement in detection accuracy by the proposed outlier decision approach over traditional thresholding (the partial area under the FROC curve increased from 3.95 to 4.25, p-value  <10-4). There was also a reduction in case-to-case variability in detected FPs at a given sensitivity level. The proposed adaptive decision approach could not only reduce the number of FPs in detected MCs but also improve case-to-case consistency in detection.

  20. Digital mammography: observer performance study of the effects of pixel size on radiologists' characterization of malignant and benign microcalcifications

    NASA Astrophysics Data System (ADS)

    Chan, Heang-Ping; Helvie, Mark A.; Petrick, Nicholas; Sahiner, Berkman; Adler, Dorit D.; Blane, Caroline E.; Joynt, Lynn K.; Paramagul, Chintana; Roubidoux, Marilyn A.; Wilson, Todd E.; Hadjiiski, Lubomir M.; Goodsitt, Mitchell M.

    1999-05-01

    A receiver operating characteristic (ROC) experiment was conducted to evaluate the effects of pixel size on the characterization of mammographic microcalcifications. Digital mammograms were obtained by digitizing screen-film mammograms with a laser film scanner. One hundred twelve two-view mammograms with biopsy-proven microcalcifications were digitized at a pixel size of 35 micrometer X 35 micrometer. A region of interest (ROI) containing the microcalcifications was extracted from each image. ROI images with pixel sizes of 70 micrometers, 105 micrometers, and 140 micrometers were derived from the ROI of 35 micrometer pixel size by averaging 2 X 2, 3 X 3, and 4 X 4 neighboring pixels, respectively. The ROI images were printed on film with a laser imager. Seven MQSA-approved radiologists participated as observers. The likelihood of malignancy of the microcalcifications was rated on a 10-point confidence rating scale and analyzed with ROC methodology. The classification accuracy was quantified by the area, Az, under the ROC curve. The statistical significance of the differences in the Az values for different pixel sizes was estimated with the Dorfman-Berbaum-Metz (DBM) method for multi-reader, multi-case ROC data. It was found that five of the seven radiologists demonstrated a higher classification accuracy with the 70 micrometer or 105 micrometer images. The average Az also showed a higher classification accuracy in the range of 70 to 105 micrometer pixel size. However, the differences in A(subscript z/ between different pixel sizes did not achieve statistical significance. The low specificity of image features of microcalcifications an the large interobserver and intraobserver variabilities may have contributed to the relatively weak dependence of classification accuracy on pixel size.

  1. Residential particulate matter and distance to roadways in relation to mammographic density: results from the Nurses' Health Studies.

    PubMed

    DuPre, Natalie C; Hart, Jaime E; Bertrand, Kimberly A; Kraft, Peter; Laden, Francine; Tamimi, Rulla M

    2017-11-23

    High mammographic density is a strong, well-established breast cancer risk factor. Three studies conducted in various smaller geographic settings reported inconsistent findings between air pollution and mammographic density. We assessed whether particulate matter (PM) exposures (PM 2.5 , PM 2.5-10 , and PM 10 ) and distance to roadways were associated with mammographic density among women residing across the United States. The Nurses' Health Studies are prospective cohorts for whom a subset has screening mammograms from the 1990s (interquartile range 1990-1999). PM was estimated using spatio-temporal models linked to residential addresses. Among 3258 women (average age at mammogram 52.7 years), we performed multivariable linear regression to assess associations between square-root-transformed mammographic density and PM within 1 and 3 years before the mammogram. For linear regression estimates of PM in relation to untransformed mammographic density outcomes, bootstrapped robust standard errors are used to calculate 95% confidence intervals (CIs). Analyses were stratified by menopausal status and region of residence. Recent PM and distance to roadways were not associated with mammographic density in premenopausal women (PM 2.5 within 3 years before mammogram β = 0.05, 95% CI -0.16, 0.27; PM 2.5-10 β = 0, 95%, CI -0.15, 0.16; PM 10 β = 0.02, 95% CI -0.10, 0.13) and postmenopausal women (PM 2.5 within 3 years before mammogram β = -0.05, 95% CI -0.27, 0.17; PM 2.5-10 β = -0.01, 95% CI -0.16, 0.14; PM 10 β = -0.02, 95% CI -0.13, 0.09). Largely null associations were observed within regions. Suggestive associations were observed among postmenopausal women in the Northeast (n = 745), where a 10-μg/m 3 increase in PM 2.5 within 3 years before the mammogram was associated with 3.4 percentage points higher percent mammographic density (95% CI -0.5, 7.3). These findings do not support that recent PM or roadway exposures influence mammographic density. Although PM was largely not associated with mammographic density, we cannot rule out the role of PM during earlier exposure time windows and possible associations among northeastern postmenopausal women.

  2. Preventive health pamphlets in the emergency department.

    PubMed

    Berger, P; Luskin, M; Krishel, S

    1998-01-01

    We conducted a prospective clinical trial to determine the effectiveness of an emergency department informational pamphlet in improving patients' compliance with recommendations that they receive Pap smears, mammograms, and a pneumococcal vaccination. Informational pamphlets were distributed to 1,000 consecutive patients who presented to a university-affiliated emergency department (ED). The pamphlet contained information stating the indications for obtaining routine Pap smears, mammograms, and a pneumococcal vaccination. Target individuals were women 18 years and older and men 65 years and older. Target patients were called approximately 2 months after their ED visits to obtain follow-up data. There were 464 target patients obtained from the 1,000 pamphlets distributed (409 female/55 male), and 68% (316) of the 464 were contacted by telephone for follow-up data. Significantly more women than men had read the pamphlet (62% vs. 8%). Of the women contacted (279), 31.9% (89) were not up to date (UTD) with Pap smears, and 11.2% (10) stated that they had scheduled an appointment for a Pap smear; 14.5% (11) of the women were not UTD with mammograms, and none had scheduled an appointment to receive care. Of the patients over age 65, 67% were not UTD with a pneumococcal vaccination, and no appointments were scheduled to obtain one. We conclude that a significant number of patients who present to this ED are in need of preventive health care. Emergency department informational pamphlets may have a role in improving Pap smear compliance. Women may be more likely then men to read informational pamphlets distributed in the ED.

  3. Abnormality detection of mammograms by discriminative dictionary learning on DSIFT descriptors.

    PubMed

    Tavakoli, Nasrin; Karimi, Maryam; Nejati, Mansour; Karimi, Nader; Reza Soroushmehr, S M; Samavi, Shadrokh; Najarian, Kayvan

    2017-07-01

    Detection and classification of breast lesions using mammographic images are one of the most difficult studies in medical image processing. A number of learning and non-learning methods have been proposed for detecting and classifying these lesions. However, the accuracy of the detection/classification still needs improvement. In this paper we propose a powerful classification method based on sparse learning to diagnose breast cancer in mammograms. For this purpose, a supervised discriminative dictionary learning approach is applied on dense scale invariant feature transform (DSIFT) features. A linear classifier is also simultaneously learned with the dictionary which can effectively classify the sparse representations. Our experimental results show the superior performance of our method compared to existing approaches.

  4. Mammogram registration: a phantom-based evaluation of compressed breast thickness variation effects.

    PubMed

    Richard, Frédéric J P; Bakić, Predrag R; Maidment, Andrew D A

    2006-02-01

    The temporal comparison of mammograms is complex; a wide variety of factors can cause changes in image appearance. Mammogram registration is proposed as a method to reduce the effects of these changes and potentially to emphasize genuine alterations in breast tissue. Evaluation of such registration techniques is difficult since ground truth regarding breast deformations is not available in clinical mammograms. In this paper, we propose a systematic approach to evaluate sensitivity of registration methods to various types of changes in mammograms using synthetic breast images with known deformations. As a first step, images of the same simulated breasts with various amounts of simulated physical compression have been used to evaluate a previously described nonrigid mammogram registration technique. Registration performance is measured by calculating the average displacement error over a set of evaluation points identified in mammogram pairs. Applying appropriate thickness compensation and using a preferred order of the registered images, we obtained an average displacement error of 1.6 mm for mammograms with compression differences of 1-3 cm. The proposed methodology is applicable to analysis of other sources of mammogram differences and can be extended to the registration of multimodality breast data.

  5. Nonrigid mammogram registration using mutual information

    NASA Astrophysics Data System (ADS)

    Wirth, Michael A.; Narhan, Jay; Gray, Derek W. S.

    2002-05-01

    Of the papers dealing with the task of mammogram registration, the majority deal with the task by matching corresponding control-points derived from anatomical landmark points. One of the caveats encountered when using pure point-matching techniques is their reliance on accurately extracted anatomical features-points. This paper proposes an innovative approach to matching mammograms which combines the use of a similarity-measure and a point-based spatial transformation. Mutual information is a cost-function used to determine the degree of similarity between the two mammograms. An initial rigid registration is performed to remove global differences and bring the mammograms into approximate alignment. The mammograms are then subdivided into smaller regions and each of the corresponding subimages is matched independently using mutual information. The centroids of each of the matched subimages are then used as corresponding control-point pairs in association with the Thin-Plate Spline radial basis function. The resulting spatial transformation generates a nonrigid match of the mammograms. The technique is illustrated by matching mammograms from the MIAS mammogram database. An experimental comparison is made between mutual information incorporating purely rigid behavior, and that incorporating a more nonrigid behavior. The effectiveness of the registration process is evaluated using image differences.

  6. The psychological impact of a false-positive screening mammogram in Barcelona.

    PubMed

    Espasa, Rebecca; Murta-Nascimento, Cristiane; Bayés, Ramón; Sala, Maria; Casamitjana, Montserrat; Macià, Francesc; Castells, Xavier

    2012-12-01

    The purpose of this study was to ascertain the psychological impact of mammographic screening for women who receive negative results and for those who need additional non-invasive and invasive complementary investigations to exclude breast cancer (false positives). One hundred fifty women who attended a breast cancer screening programme in Barcelona, aged 50-69 years, were included in this study: 50 with negative results and 100 with false positive mammograms (50 underwent non-invasive and 50 underwent invasive complementary investigations). Participants worried little until they underwent mammography, but worries increased when a telephone call notified the women of the need for further testing. A substantial proportion of women requiring further assessment reported that they were at least somewhat worried about having breast cancer throughout the screening process (P < 0.0001). Nevertheless, levels of anxiety and depression, measured by the Hospital Anxiety and Depression Scale, showed no statistically significant differences among the three groups. In conclusion, although the women showed no psychological morbidity, there is a substantial psychological response in those with an abnormal screening mammogram.

  7. Mutual information-based template matching scheme for detection of breast masses: from mammography to digital breast tomosynthesis

    PubMed Central

    Mazurowski, Maciej A; Lo, Joseph Y; Harrawood, Brian P; Tourassi, Georgia D

    2011-01-01

    Development of a computational decision aid for a new medical imaging modality typically is a long and complicated process. It consists of collecting data in the form of images and annotations, development of image processing and pattern recognition algorithms for analysis of the new images and finally testing of the resulting system. Since new imaging modalities are developed more rapidly than ever before, any effort for decreasing the time and cost of this development process could result in maximizing the benefit of the new imaging modality to patients by making the computer aids quickly available to radiologists that interpret the images. In this paper, we make a step in this direction and investigate the possibility of translating the knowledge about the detection problem from one imaging modality to another. Specifically, we present a computer-aided detection (CAD) system for mammographic masses that uses a mutual information-based template matching scheme with intelligently selected templates. We presented principles of template matching with mutual information for mammography before. In this paper, we present an implementation of those principles in a complete computer-aided detection system. The proposed system, through an automatic optimization process, chooses the most useful templates (mammographic regions of interest) using a large database of previously collected and annotated mammograms. Through this process, the knowledge about the task of detecting masses in mammograms is incorporated in the system. Then we evaluate whether our system developed for screen-film mammograms can be successfully applied not only to other mammograms but also to digital breast tomosynthesis (DBT) reconstructed slices without adding any DBT cases for training. Our rationale is that since mutual information is known to be a robust intermodality image similarity measure, it has high potential of transferring knowledge between modalities in the context of the mass detection task. Experimental evaluation of the system on mammograms showed competitive performance compared to other mammography CAD systems recently published in the literature. When the system was applied “as-is” to DBT, its performance was notably worse than that for mammograms. However, with a simple additional preprocessing step, the performance of the system reached levels similar to that obtained for mammograms. In conclusion, the presented CAD system not only performed competitively on screen-film mammograms but it also performed robustly on DBT showing that direct transfer of knowledge across breast imaging modalities for mass detection is in fact possible. PMID:21554985

  8. Visual assessment of breast density using Visual Analogue Scales: observer variability, reader attributes and reading time

    NASA Astrophysics Data System (ADS)

    Ang, Teri; Harkness, Elaine F.; Maxwell, Anthony J.; Lim, Yit Y.; Emsley, Richard; Howell, Anthony; Evans, D. Gareth; Astley, Susan; Gadde, Soujanya

    2017-03-01

    Breast density is a strong risk factor for breast cancer and has potential use in breast cancer risk prediction, with subjective methods of density assessment providing a strong relationship with the development of breast cancer. This study aims to assess intra- and inter-observer variability in visual density assessment recorded on Visual Analogue Scales (VAS) among trained readers, and examine whether reader age, gender and experience are associated with assessed density. Eleven readers estimated the breast density of 120 mammograms on two occasions 3 years apart using VAS. Intra- and inter-observer agreement was assessed with Intraclass Correlation Coefficient (ICC) and variation between readers visualised on Bland-Altman plots. The mean scores of all mammograms per reader were used to analyse the effect of reader attributes on assessed density. Excellent intra-observer agreement (ICC>0.80) was found in the majority of the readers. All but one reader had a mean difference of <10 percentage points from the first to the second reading. Inter-observer agreement was excellent for consistency (ICC 0.82) and substantial for absolute agreement (ICC 0.69). However, the 95% limits of agreement for pairwise differences were -6.8 to 15.7 at the narrowest and 0.8 to 62.3 at the widest. No significant association was found between assessed density and reader age, experience or gender, or with reading time. Overall, the readers were consistent in their scores, although some large variations were observed. Reader evaluation and targeted training may alleviate this problem.

  9. A deep learning method for classifying mammographic breast density categories.

    PubMed

    Mohamed, Aly A; Berg, Wendie A; Peng, Hong; Luo, Yahong; Jankowitz, Rachel C; Wu, Shandong

    2018-01-01

    Mammographic breast density is an established risk marker for breast cancer and is visually assessed by radiologists in routine mammogram image reading, using four qualitative Breast Imaging and Reporting Data System (BI-RADS) breast density categories. It is particularly difficult for radiologists to consistently distinguish the two most common and most variably assigned BI-RADS categories, i.e., "scattered density" and "heterogeneously dense". The aim of this work was to investigate a deep learning-based breast density classifier to consistently distinguish these two categories, aiming at providing a potential computerized tool to assist radiologists in assigning a BI-RADS category in current clinical workflow. In this study, we constructed a convolutional neural network (CNN)-based model coupled with a large (i.e., 22,000 images) digital mammogram imaging dataset to evaluate the classification performance between the two aforementioned breast density categories. All images were collected from a cohort of 1,427 women who underwent standard digital mammography screening from 2005 to 2016 at our institution. The truths of the density categories were based on standard clinical assessment made by board-certified breast imaging radiologists. Effects of direct training from scratch solely using digital mammogram images and transfer learning of a pretrained model on a large nonmedical imaging dataset were evaluated for the specific task of breast density classification. In order to measure the classification performance, the CNN classifier was also tested on a refined version of the mammogram image dataset by removing some potentially inaccurately labeled images. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to measure the accuracy of the classifier. The AUC was 0.9421 when the CNN-model was trained from scratch on our own mammogram images, and the accuracy increased gradually along with an increased size of training samples. Using the pretrained model followed by a fine-tuning process with as few as 500 mammogram images led to an AUC of 0.9265. After removing the potentially inaccurately labeled images, AUC was increased to 0.9882 and 0.9857 for without and with the pretrained model, respectively, both significantly higher (P < 0.001) than when using the full imaging dataset. Our study demonstrated high classification accuracies between two difficult to distinguish breast density categories that are routinely assessed by radiologists. We anticipate that our approach will help enhance current clinical assessment of breast density and better support consistent density notification to patients in breast cancer screening. © 2017 American Association of Physicists in Medicine.

  10. Deep learning and three-compartment breast imaging in breast cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Drukker, Karen; Huynh, Benjamin Q.; Giger, Maryellen L.; Malkov, Serghei; Avila, Jesus I.; Fan, Bo; Joe, Bonnie; Kerlikowske, Karla; Drukteinis, Jennifer S.; Kazemi, Leila; Pereira, Malesa M.; Shepherd, John

    2017-03-01

    We investigated whether deep learning has potential to aid in the diagnosis of breast cancer when applied to mammograms and biologic tissue composition images derived from three-compartment (3CB) imaging. The dataset contained diagnostic mammograms and 3CB images (water, lipid, and protein content) of biopsy-sampled BIRADS 4 and 5 lesions in 195 patients. In 58 patients, the lesion manifested as a mass (13 malignant vs. 45 benign), in 87 as microcalcifications (19 vs. 68), and in 56 as (focal) asymmetry or architectural distortion (11 vs. 45). Six patients had both a mass and calcifications. For each mammogram and corresponding 3CB images, a 128x128 region of interest containing the lesion was selected by an expert radiologist and used directly as input to a deep learning method pretrained on a very large independent set of non-medical images. We used a nested leave-one-out-by-case (patient) model selection and classification protocol. The area under the ROC curve (AUC) for the task of distinguishing between benign and malignant lesions was used as performance metric. For the cases with mammographic masses, the AUC increased from 0.83 (mammograms alone) to 0.89 (mammograms+3CB, p=.162). For the microcalcification and asymmetry/architectural distortion cases the AUC increased from 0.84 to 0.91 (p=.116) and from 0.61 to 0.87 (p=.006), respectively. Our results indicate great potential for the application of deep learning methods in the diagnosis of breast cancer and additional knowledge of the biologic tissue composition appeared to improve performance, especially for lesions mammographically manifesting as asymmetries or architectural distortions.

  11. Detection of simulated microcalcifications in fixed mammary tissue: An ROC study of the effect of local versus global histogram equalization.

    PubMed

    Sund, T; Olsen, J B

    2006-09-01

    To investigate whether sliding window adaptive histogram equalization (SWAHE) of digital mammograms improves the detection of simulated calcifications, as compared to images normalized by global histogram equalization (GHE). Direct digital mammograms were obtained from mammary tissue phantoms superimposed with different frames. Each frame was divided into forty squares by a wire mesh, and contained granular calcifications randomly positioned in about 50% of the squares. Three radiologists read the mammograms on a display monitor. They classified their confidence in the presence of microcalcifications in each square on a scale of 1 to 5. Images processed with GHE were first read and used as a reference. In a later session, the same images processed with SWAHE were read. The results were compared using ROC methodology. When the total areas AZ were compared, the results were completely equivocal. When comparing the high-specificity partial ROC area AZ,0.2 below false-positive fraction (FPF) 0.20, two of the three observers performed best with the images processed with SWAHE. The difference was not statistically significant. When the reader's confidence threshold in malignancy is set at a high level, increasing the contrast of mammograms with SWAHE may enhance the visibility of microcalcifications without adversely affecting the false-positive rate. When the reader's confidence threshold is set at a low level, the effect of SWAHE is an increase of false positives. Further investigation is needed to confirm the validity of the conclusions.

  12. Contrast enhanced dual energy spectral mammogram, an emerging addendum in breast imaging.

    PubMed

    Kariyappa, Kalpana D; Gnanaprakasam, Francis; Anand, Subhapradha; Krishnaswami, Murali; Ramachandran, Madan

    2016-11-01

    To assess the role of contrast-enhanced dual-energy spectral mammogram (CEDM) as a problem-solving tool in equivocal cases. 44 consenting females with equivocal findings on full-field digital mammogram underwent CEDM. All the images were interpreted by two radiologists independently. Confidence of presence was plotted on a three-point Likert scale and probability of cancer was assigned on Breast Imaging Reporting and Data System scoring. Histopathology was taken as the gold standard. Statistical analyses of all variables were performed. 44 breast lesions were included in the study, among which 77.3% lesions were malignant or precancerous and 22.7% lesions were benign or inconclusive. 20% of lesions were identified only on CEDM. True extent of the lesion was made out in 15.9% of cases, multifocality was established in 9.1% of cases and ductal extension was demonstrated in 6.8% of cases. Statistical significance for CEDM was p-value <0.05. Interobserver kappa value was 0.837. CEDM has a useful role in identifying occult lesions in dense breasts and in triaging lesions. In a mammographically visible lesion, CEDM characterizes the lesion, affirms the finding and better demonstrates response to treatment. Hence, we conclude that CEDM is a useful complementary tool to standard mammogram. Advances in knowledge: CEDM can detect and demonstrate lesions even in dense breasts with the advantage of feasibility of stereotactic biopsy in the same setting. Hence, it has the potential to be a screening modality with need for further studies and validation.

  13. Effect of spatial noise of medical grade Liquid Crystal Displays (LCD) on the detection of micro-calcification

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Fan, Jiahua; Dallas, William J.; Krupinski, Elizabeth A.; Johnson, Jeffrey

    2009-08-01

    This presentation describes work in progress that is the result of an NIH SBIR Phase 1 project that addresses the wide- spread concern for the large number of breast-cancers and cancer victims [1,2]. The primary goal of the project is to increase the detection rate of microcalcifications as a result of the decrease of spatial noise of the LCDs used to display the mammograms [3,4]. Noise reduction is to be accomplished with the aid of a high performance CCD camera and subsequent application of local-mean equalization and error diffusion [5,6]. A second goal of the project is the actual detection of breast cancer. Contrary to the approach to mammography, where the mammograms typically have a pixel matrix of approximately 1900 x 2300 pixels, otherwise known as FFDM or Full-Field Digital Mammograms, we will only use sections of mammograms with a pixel matrix of 256 x 256 pixels. This is because at this time, reduction of spatial noise on an LCD can only be done on relatively small areas like 256 x 256 pixels. In addition, judging the efficacy for detection of breast cancer will be done using two methods: One is a conventional ROC study [7], the other is a vision model developed over several years starting at the Sarnoff Research Center and continuing at the Siemens Corporate Research in Princeton NJ [8].

  14. Adaptive multiscale processing for contrast enhancement

    NASA Astrophysics Data System (ADS)

    Laine, Andrew F.; Song, Shuwu; Fan, Jian; Huda, Walter; Honeyman, Janice C.; Steinbach, Barbara G.

    1993-07-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms within a continuum of scale space and used to enhance features of importance to mammography. Choosing analyzing functions that are well localized in both space and frequency, results in a powerful methodology for image analysis. We describe methods of contrast enhancement based on two overcomplete (redundant) multiscale representations: (1) Dyadic wavelet transform (2) (phi) -transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by non-linear, logarithmic and constant scale-space weight functions. Multiscale edges identified within distinct levels of transform space provide a local support for enhancement throughout each decomposition. We demonstrate that features extracted from wavelet spaces can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  15. Investigating the link between the radiological experience and the allocation of an 'equivocal finding'

    NASA Astrophysics Data System (ADS)

    Rawashdeh, Mohammad A.; Vidotti, Camila; Lee, Warwick; Lewis, Sarah J.; Mello-Thoms, Claudia; Reed, Warren M.; Tapia, Kriscia; Brennan, Patrick C.

    2016-03-01

    Rationale and Objectives: This study will investigate the link between radiologists' experience in reporting mammograms, their caseloads and the decision to give a classification of Royal Australian and New Zealand College of Radiologists (RANZCR) category `3' (indeterminate or equivocal finding). Methods: A test set of 60 mammograms comprising of 20 abnormal and 40 normal cases were shown to 92 radiologists. Each radiologist was asked to identify and localize abnormalities and provide a RANZCR assessment category. Details were obtained from each reader regarding their experience, qualifications and breast reading activities. `Equivocal fractions' were calculated by dividing the number of `equivocal findings' given by each radiologist in the abnormal and normal cases by the total number of cases analyzed: 20 and 40 respectively. The `equivocal fractions' for each of the groups (normal vs abnormal) were calculated and independently correlated with age, number of years since qualification as a radiologist, number of years reading mammograms, number of mammograms read per year, number of hours reading mammograms per week and number of mammograms read over lifetime (the number of years reading mammograms multiplied by the number of mammograms read per year). The non-parametric Spearman test was used. Results: Statistically negative correlations were noted between `equivocal fractions' for the following groups: • For abnormal cases: hours per week (r= -0.38 P= 0.0001) • For normal cases: total number of mammograms read per year (r= -0.29, P= 0.006); number of mammograms read over lifetime (r= -0.21, P= 0.049)); hours reading mammograms per week (r= - 0.20, P= 0.05). Conclusion: Radiologists with greater reading experience assign fewer RANZCR category 3 or equivocal classifications. The findings have implications for screening program efficacy and recall rates. This work is still in progress and further data will be presented at the conference.

  16. Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists

    PubMed Central

    Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.

    2011-01-01

    Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance. PMID:15601640

  17. TU-F-18C-09: Mammogram Surveillance Using Texture Analysis for Breast Cancer Patients After Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuo, H; Tome, W; FOX, J

    2014-06-15

    Purpose: To study the feasibility of applying cancer risk model established from treated patients to predict the risk of recurrence on follow-up mammography after radiation therapy for both ipsilateral and contralateral breast. Methods: An extensive set of textural feature functions was applied to a set of 196 Mammograms from 50 patients. 56 Mammograms from 28 patients were used as training set, 44 mammograms from 22 patients were used as test set and the rest were used for prediction. Feature functions include Histogram, Gradient, Co-Occurrence Matrix, Run-Length Matrix and Wavelet Energy. An optimum subset of the feature functions was selected bymore » Fisher Coefficient (FO) or Mutual Information (MI) (up to top 10 features) or a method combined FO, MI and Principal Component (FMP) (up to top 30 features). One-Nearest Neighbor (1-NN), Linear Discriminant Analysis (LDA) and Nonlinear Discriminant Analysis (NDA) were utilized to build a risk model of breast cancer from the training set of mammograms at the time of diagnosis. The risk model was then used to predict the risk of recurrence from mammogram taken one year and three years after RT. Results: FPM with NDA has the best classification power in classifying the training set of the mammogram with lesions versus those without lesions. The model of FPM with NDA achieved a true positive (TP) rate of 82% compared to 45.5% of using FO with 1-NN. The best false positive (FP) rates were 0% and 3.6% in contra-lateral breast of 1-year and 3-years after RT, and 10.9% in ipsi-lateral breast of 3-years after RT. Conclusion: Texture analysis offers high dimension to differentiate breast tissue in mammogram. Using NDA to classify mammogram with lesion from mammogram without lesion, it can achieve rather high TP and low FP in the surveillance of mammogram for patient with conservative surgery combined RT.« less

  18. Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group.

    PubMed

    Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R

    2000-09-01

    To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.

  19. A method to determine the mammographic regions that show early changes due to the development of breast cancer

    NASA Astrophysics Data System (ADS)

    Karemore, Gopal; Nielsen, Mads; Karssemeijer, Nico; Brandt, Sami S.

    2014-11-01

    It is well understood nowadays that changes in the mammographic parenchymal pattern are an indicator of a risk of breast cancer and we have developed a statistical method that estimates the mammogram regions where the parenchymal changes, due to breast cancer, occur. This region of interest is computed from a score map by utilising the anatomical breast coordinate system developed in our previous work. The method also makes an automatic scale selection to avoid overfitting while the region estimates are computed by a nested cross-validation scheme. In this way, it is possible to recover those mammogram regions that show a significant difference in classification scores between the cancer and the control group. Our experiments suggested that the most significant mammogram region is the region behind the nipple and that can be justified by previous findings from other research groups. This result was conducted on the basis of the cross-validation experiments on independent training, validation and testing sets from the case-control study of 490 women, of which 245 women were diagnosed with breast cancer within a period of 2-4 years after the baseline mammograms. We additionally generalised the estimated region to another, mini-MIAS study and showed that the transferred region estimate gives at least a similar classification result when compared to the case where the whole breast region is used. In all, by following our method, one most likely improves both preclinical and follow-up breast cancer screening, but a larger study population will be required to test this hypothesis.

  20. Contrast enhanced dual energy spectral mammogram, an emerging addendum in breast imaging

    PubMed Central

    Gnanaprakasam, Francis; Anand, Subhapradha; Krishnaswami, Murali; Ramachandran, Madan

    2016-01-01

    Objective: To assess the role of contrast-enhanced dual-energy spectral mammogram (CEDM) as a problem-solving tool in equivocal cases. Methods: 44 consenting females with equivocal findings on full-field digital mammogram underwent CEDM. All the images were interpreted by two radiologists independently. Confidence of presence was plotted on a three-point Likert scale and probability of cancer was assigned on Breast Imaging Reporting and Data System scoring. Histopathology was taken as the gold standard. Statistical analyses of all variables were performed. Results: 44 breast lesions were included in the study, among which 77.3% lesions were malignant or precancerous and 22.7% lesions were benign or inconclusive. 20% of lesions were identified only on CEDM. True extent of the lesion was made out in 15.9% of cases, multifocality was established in 9.1% of cases and ductal extension was demonstrated in 6.8% of cases. Statistical significance for CEDM was p-value <0.05. Interobserver kappa value was 0.837. Conclusion: CEDM has a useful role in identifying occult lesions in dense breasts and in triaging lesions. In a mammographically visible lesion, CEDM characterizes the lesion, affirms the finding and better demonstrates response to treatment. Hence, we conclude that CEDM is a useful complementary tool to standard mammogram. Advances in knowledge: CEDM can detect and demonstrate lesions even in dense breasts with the advantage of feasibility of stereotactic biopsy in the same setting. Hence, it has the potential to be a screening modality with need for further studies and validation. PMID:27610475

  1. The classification of normal screening mammograms

    NASA Astrophysics Data System (ADS)

    Ang, Zoey Z. Y.; Rawashdeh, Mohammad A.; Heard, Robert; Brennan, Patrick C.; Lee, Warwick; Lewis, Sarah J.

    2016-03-01

    Rationale and objectives: To understand how breast screen readers classify the difficulty of normal screening mammograms using common lexicon describing normal appearances. Cases were also assessed on their suitability for a single reader strategy. Materials and Methods: 15 breast readers were asked to interpret a test set of 29 normal screening mammogram cases and classify them by rating the difficulty of the case on a five-point Likert scale, identifying the salient features and assessing their suitability for single reading. Using the False Positive Fractions from a previous study, the 29 cases were classified into 10 "low", 10 "medium" and nine "high" difficulties. Data was analyzed with descriptive statistics. Spearman's correlation was used to test the strength of association between the difficulty of the cases and the readers' recommendation for single reading strategy. Results: The ratings from readers in this study corresponded to the known difficulty level of cases for the 'low' and 'high' difficulty cases. Uniform ductal pattern and density, symmetrical mammographic features and the absence of micro-calcifications were the main reasons associated with 'low' difficulty cases. The 'high' difficulty cases were described as having `dense breasts'. There was a statistically significant negative correlation between the difficulty of the cases and readers' recommendation for single reading (r = -0.475, P = 0.009). Conclusion: The findings demonstrated potential relationships between certain mammographic features and the difficulty for readers to classify mammograms as 'normal'. The standard Australian practice of double reading was deemed more suitable for most cases. There was an inverse moderate association between the difficulty of the cases and the recommendations for single reading.

  2. Hexagonal wavelet processing of digital mammography

    NASA Astrophysics Data System (ADS)

    Laine, Andrew F.; Schuler, Sergio; Huda, Walter; Honeyman-Buck, Janice C.; Steinbach, Barbara G.

    1993-09-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms and used to enhance features of importance to mammography within a continuum of scale-space. We present a method of contrast enhancement based on an overcomplete, non-separable multiscale representation: the hexagonal wavelet transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by local and global non-linear operators. Multiscale edges identified within distinct levels of transform space provide local support for enhancement. We demonstrate that features extracted from multiresolution representations can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  3. Semiautomatic estimation of breast density with DM-Scan software.

    PubMed

    Martínez Gómez, I; Casals El Busto, M; Antón Guirao, J; Ruiz Perales, F; Llobet Azpitarte, R

    2014-01-01

    To evaluate the reproducibility of the calculation of breast density with DM-Scan software, which is based on the semiautomatic segmentation of fibroglandular tissue, and to compare it with the reproducibility of estimation by visual inspection. The study included 655 direct digital mammograms acquired using craniocaudal projections. Three experienced radiologists analyzed the density of the mammograms using DM-Scan, and the inter- and intra-observer agreement between pairs of radiologists for the Boyd and BI-RADS® scales were calculated using the intraclass correlation coefficient. The Kappa index was used to compare the inter- and intra-observer agreements with those obtained previously for visual inspection in the same set of images. For visual inspection, the mean interobserver agreement was 0,876 (95% CI: 0,873-0,879) on the Boyd scale and 0,823 (95% CI: 0,818-0,829) on the BI-RADS® scale. The mean intraobserver agreement was 0,813 (95% CI: 0,796-0,829) on the Boyd scale and 0,770 (95% CI: 0,742-0,797) on the BI-RADS® scale. For DM-Scan, the mean inter- and intra-observer agreement was 0,92, considerably higher than the agreement for visual inspection. The semiautomatic calculation of breast density using DM-Scan software is more reliable and reproducible than visual estimation and reduces the subjectivity and variability in determining breast density. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.

  4. Use of volumetric features for temporal comparison of mass lesions in full field digital mammograms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozek, Jelena, E-mail: jelena.bozek@fer.hr; Grgic, Mislav; Kallenberg, Michiel

    2014-02-15

    Purpose: Temporal comparison of lesions might improve classification between benign and malignant lesions in full-field digital mammograms (FFDM). The authors compare the use of volumetric features for lesion classification, which are computed from dense tissue thickness maps, to the use of mammographic lesion area. Use of dense tissue thickness maps for lesion characterization is advantageous, since it results in lesion features that are invariant to acquisition parameters. Methods: The dataset used in the analysis consisted of 60 temporal mammogram pairs comprising 120 mediolateral oblique or craniocaudal views with a total of 65 lesions, of which 41 were benign and 24more » malignant. The authors analyzed the performance of four volumetric features, area, and four other commonly used features obtained from temporal mammogram pairs, current mammograms, and prior mammograms. The authors evaluated the individual performance of all features and of different feature sets. The authors used linear discriminant analysis with leave-one-out cross validation to classify different feature sets. Results: Volumetric features from temporal mammogram pairs achieved the best individual performance, as measured by the area under the receiver operating characteristic curve (A{sub z} value). Volume change (A{sub z} = 0.88) achieved higher A{sub z} value than projected lesion area change (A{sub z} = 0.78) in the temporal comparison of lesions. Best performance was achieved with a set that consisted of a set of features extracted from the current exam combined with four volumetric features representing changes with respect to the prior mammogram (A{sub z} = 0.90). This was significantly better (p = 0.005) than the performance obtained using features from the current exam only (A{sub z} = 0.77). Conclusions: Volumetric features from temporal mammogram pairs combined with features from the single exam significantly improve discrimination of benign and malignant lesions in FFDM mammograms compared to using only single exam features. In the comparison with prior mammograms, use of volumetric change may lead to better performance than use of lesion area change.« less

  5. Malpractice issues in radiology: medicare compliance versus standard of care conformance--real or imaginary conflict?

    PubMed

    Duszak, Richard; Berlin, Leonard

    2010-06-01

    Plaintiff's Attorney (Pl Att:: Doctor, the record shows that the patient was referred to the hospital's radiology department by her gynecologist for a screening mammogram. The record also shows that when completing the mammography information form, the patient wrote that she had a lump in her left breast, correct? Defendant Radiologist (Df Ra:): Yes. Pl Att: But your technologist performed, and you interpreted, a screening mammogram. Doesn't the radiology standard of care require you to do a diagnostic mammogram when the patient has a breast lump? Df Ra:: Well, normally yes, but if it's going to be a diagnostic mammogram, then the referring physician has to order it. In this case our tech called the gynecologist and asked him whether he wanted to order a diagnostic study, and he said no, he didn't feel the lump, and that we should only do a plain screening mammogram. Pl Att:: Please explain something. You're agreeing that a woman with a breast lump should have a diagnostic mammogram, but you are saying that you didn't do one because the patient's physician wouldn't order it? Don't you have a duty to do the diagnostic mammogram in a case like this on your own, without having to ask permission from the patient's gynecologist? Df Ra:: Only the treating physician can change a screening mammogram into a diagnostic mammogram, and I am not the treating physician. If I went ahead and did a diagnostic mammography examination on my own, it would be Medicare fraud, and our hospital's compliance officer says it could result in our hospital being fined and thrown out of the Medicare program. Pl Atty: What prevents you then from recommending-not ordering, but just recommending-a diagnostic mammogram in your report, because the patient says she's got a lump? Df Rad: Well, according to our hospital's compliance officer, that would also be fraud.

  6. Ant-cuckoo colony optimization for feature selection in digital mammogram.

    PubMed

    Jona, J B; Nagaveni, N

    2014-01-15

    Digital mammogram is the only effective screening method to detect the breast cancer. Gray Level Co-occurrence Matrix (GLCM) textural features are extracted from the mammogram. All the features are not essential to detect the mammogram. Therefore identifying the relevant feature is the aim of this work. Feature selection improves the classification rate and accuracy of any classifier. In this study, a new hybrid metaheuristic named Ant-Cuckoo Colony Optimization a hybrid of Ant Colony Optimization (ACO) and Cuckoo Search (CS) is proposed for feature selection in Digital Mammogram. ACO is a good metaheuristic optimization technique but the drawback of this algorithm is that the ant will walk through the path where the pheromone density is high which makes the whole process slow hence CS is employed to carry out the local search of ACO. Support Vector Machine (SVM) classifier with Radial Basis Kernal Function (RBF) is done along with the ACO to classify the normal mammogram from the abnormal mammogram. Experiments are conducted in miniMIAS database. The performance of the new hybrid algorithm is compared with the ACO and PSO algorithm. The results show that the hybrid Ant-Cuckoo Colony Optimization algorithm is more accurate than the other techniques.

  7. Normal and abnormal tissue identification system and method for medical images such as digital mammograms

    NASA Technical Reports Server (NTRS)

    Heine, John J. (Inventor); Clarke, Laurence P. (Inventor); Deans, Stanley R. (Inventor); Stauduhar, Richard Paul (Inventor); Cullers, David Kent (Inventor)

    2001-01-01

    A system and method for analyzing a medical image to determine whether an abnormality is present, for example, in digital mammograms, includes the application of a wavelet expansion to a raw image to obtain subspace images of varying resolution. At least one subspace image is selected that has a resolution commensurate with a desired predetermined detection resolution range. A functional form of a probability distribution function is determined for each selected subspace image, and an optimal statistical normal image region test is determined for each selected subspace image. A threshold level for the probability distribution function is established from the optimal statistical normal image region test for each selected subspace image. A region size comprising at least one sector is defined, and an output image is created that includes a combination of all regions for each selected subspace image. Each region has a first value when the region intensity level is above the threshold and a second value when the region intensity level is below the threshold. This permits the localization of a potential abnormality within the image.

  8. Method for simulating dose reduction in digital mammography using the Anscombe transformation.

    PubMed

    Borges, Lucas R; Oliveira, Helder C R de; Nunes, Polyana F; Bakic, Predrag R; Maidment, Andrew D A; Vieira, Marcelo A C

    2016-06-01

    This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.

  9. Modeling of digital mammograms using bicubic spline functions and additive noise

    NASA Astrophysics Data System (ADS)

    Graffigne, Christine; Maintournam, Aboubakar; Strauss, Anne

    1998-09-01

    The purpose of our work is the microcalcifications detection on digital mammograms. In order to do so, we model the grey levels of digital mammograms by the sum of a surface trend (bicubic spline function) and an additive noise or texture. We also introduce a robust estimation method in order to overcome the bias introduced by the microcalcifications. After the estimation we consider the subtraction image values as noise. If the noise is not correlated, we adjust its distribution probability by the Pearson's system of densities. It allows us to threshold accurately the images of subtraction and therefore to detect the microcalcifications. If the noise is correlated, a unilateral autoregressive process is used and its coefficients are again estimated by the least squares method. We then consider non overlapping windows on the residues image. In each window the texture residue is computed and compared with an a priori threshold. This provides correct localization of the microcalcifications clusters. However this technique is definitely more time consuming that then automatic threshold assuming uncorrelated noise and does not lead to significantly better results. As a conclusion, even if the assumption of uncorrelated noise is not correct, the automatic thresholding based on the Pearson's system performs quite well on most of our images.

  10. Mammography screening using independent double reading with consensus: is there a potential benefit for computer-aided detection?

    PubMed

    Skaane, Per; Kshirsagar, Ashwini; Hofvind, Solveig; Jahr, Gunnar; Castellino, Ronald A

    2012-04-01

    Double reading improves the cancer detection rate in mammography screening. Single reading with computer-aided detection (CAD) has been considered to be an alternative to double reading. Little is known about the potential benefit of CAD in breast cancer screening with double reading. To compare prospective independent double reading of screen-film (SFM) and full-field digital (FFDM) mammography in population-based screening with retrospective standalone CAD performance on the baseline mammograms of the screen-detected cancers and subsequent cancers diagnosed during the follow-up period. The study had ethics committee approval. A 5-point rating scale for probability of cancer was used for 23,923 (SFM = 16,983; FFDM = 6940) screening mammograms. Of 208 evaluable cancers, 104 were screen-detected and 104 were subsequent (44 interval and 60 next screening round) cancers. Baseline mammograms of subsequent cancers were retrospectively classified in consensus without information about cancer location, histology, or CAD prompting as normal, non-specific minimal signs, significant minimal signs, and false-negatives. The baseline mammograms of the screen-detected cancers and subsequent cancers were evaluated by CAD. Significant minimal signs and false-negatives were considered 'actionable' and potentially diagnosable if correctly prompted by CAD. CAD correctly marked 94% (98/104) of the baseline mammograms of the screen-detected cancers (SFM = 95% [61/64]; FFDM = 93% [37/40]), including 96% (23/24) of those with discordant interpretations. Considering only those baseline examinations of subsequent cancers prospectively interpreted as normal and retrospectively categorized as 'actionable', CAD input at baseline screening had the potential to increase the cancer detection rate from 0.43% to 0.51% (P = 0.13); and to increase cancer detection by 16% ([104 + 17]/104) and decrease interval cancers by 20% (from 44 to 35). CAD may have the potential to increase cancer detection by up to 16%, and to reduce the number of interval cancers by up to 20% in SFM and FFDM screening programs using independent double reading with consensus review. The influence of true- and false-positive CAD marks on decision-making can, however, only be evaluated in a prospective clinical study.

  11. Mammography Among Women With Severe Mental Illness: Exploring Disparities Through a Large Retrospective Cohort Study.

    PubMed

    Thomas, Melanie; James, Monique; Vittinghoff, Eric; Creasman, Jennifer M; Schillinger, Dean; Mangurian, Christina

    2018-01-01

    This study examined mammogram screening rates among women with severe mental illness by using a socioecological framework. Because it has been shown that people with severe mental illness receive less preventive health care overall, the analysis included psychosocial predictors of mammogram screening rates in a cohort of women with severe mental illness. This retrospective cohort study (N=14,651) used existing statewide data for women ages 48-67 in California with Medicaid insurance who received treatment in the specialty mental health care system. The primary outcome of interest was evidence of breast cancer screening via mammogram. The associations of each predictor of interest with mammogram screening were evaluated by using Poisson models with robust standard errors. Across all demographic and diagnostic categories, rates of breast cancer screening in this cohort of women with severe mental illness fell below the national average. Only 26.3% (3,859/14,651) of women in the cohort received breast cancer screening in the past year. This study replicated previous findings that women with schizophrenia spectrum disorder and those with a comorbid substance use disorder are less likely to receive screening than those with other types of mental illness. In this cohort of women with severe mental illness, evidence of nonpsychiatric health care utilization was strongly associated with breast cancer screening (adjusted risk ratio=3.30, 95% confidence interval=2.61-4.16, p<.001). The findings can inform efforts to improve breast cancer screening among women with severe mental illness, such as targeted outreach to population subsets and colocation of primary care services in mental health treatment settings.

  12. Wavelet processing techniques for digital mammography

    NASA Astrophysics Data System (ADS)

    Laine, Andrew F.; Song, Shuwu

    1992-09-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Similar to traditional coarse to fine matching strategies, the radiologist may first choose to look for coarse features (e.g., dominant mass) within low frequency levels of a wavelet transform and later examine finer features (e.g., microcalcifications) at higher frequency levels. In addition, features may be extracted by applying geometric constraints within each level of the transform. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet representations, enhanced by linear, exponential and constant weight functions through scale space. By improving the visualization of breast pathology we can improve the chances of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  13. Multi-image CAD employing features derived from ipsilateral mammographic views

    NASA Astrophysics Data System (ADS)

    Good, Walter F.; Zheng, Bin; Chang, Yuan-Hsiang; Wang, Xiao Hui; Maitz, Glenn S.; Gur, David

    1999-05-01

    On mammograms, certain kinds of features related to masses (e.g., location, texture, degree of spiculation, and integrated density difference) tend to be relatively invariant, or at last predictable, with respect to breast compression. Thus, ipsilateral pairs of mammograms may contain information not available from analyzing single views separately. To demonstrate the feasibility of incorporating multi-view features into CAD algorithm, `single-image' CAD was applied to each individual image in a set of 60 ipsilateral studies, after which all possible pairs of suspicious regions, consisting of one from each view, were formed. For these 402 pairs we defined and evaluated `multi-view' features such as: (1) relative position of centers of regions; (2) ratio of lengths of region projections parallel to nipple axis lines; (3) ratio of integrated contrast difference; (4) ratio of the sizes of the suspicious regions; and (5) measure of relative complexity of region boundaries. Each pair was identified as either a `true positive/true positive' (T) pair (i.e., two regions which are projections of the same actual mass), or as a falsely associated pair (F). Distributions for each feature were calculated. A Bayesian network was trained and tested to classify pairs of suspicious regions based exclusively on the multi-view features described above. Distributions for all features were significantly difference for T versus F pairs as indicated by likelihood ratios. Performance of the Bayesian network, which was measured by ROC analysis, indicates a significant ability to distinguish between T pairs and F pairs (Az equals 0.82 +/- 0.03), using information that is attributed to the multi-view content. This study is the first demonstration that there is a significant amount of spatial information that can be derived from ipsilateral pairs of mammograms.

  14. Hospitalized women's willingness to pay for an inpatient screening mammogram.

    PubMed

    Khaliq, Waseem; Harris, Ché Matthew; Landis, Regina; Bridges, John F P; Wright, Scott M

    2014-01-01

    Lower rates for breast cancer screening persist among low income and uninsured women. Although Medicare and many other insurance plans would pay for screening mammograms done during hospital stays, breast cancer screening has not been part of usual hospital care. This study explores the mean amount of money that hospitalized women were willing to contribute towards the cost of a screening mammogram. Of the 193 enrolled patients, 72% were willing to pay a mean of $83.41 (95% CI, $71.51-$95.31) in advance towards inpatient screening mammogram costs. The study's findings suggest that hospitalized women value the prospect of screening mammography during the hospitalization. It may be wise policy to offer mammograms to nonadherent hospitalized women, especially those who are at high risk for developing breast cancer. © 2014 Annals of Family Medicine, Inc.

  15. Automatic detection of the breast border and nipple position on digital mammograms using genetic algorithm for asymmetry approach to detection of microcalcifications.

    PubMed

    Karnan, M; Thangavel, K

    2007-07-01

    The presence of microcalcifications in breast tissue is one of the most incident signs considered by radiologist for an early diagnosis of breast cancer, which is one of the most common forms of cancer among women. In this paper, the Genetic Algorithm (GA) is proposed for automatic look at commonly prone area the breast border and nipple position to discover the suspicious regions on digital mammograms based on asymmetries between left and right breast image. The basic idea of the asymmetry approach is to scan left and right images are subtracted to extract the suspicious region. The proposed system consists of two steps: First, the mammogram images are enhanced using median filter, normalize the image, at the pectoral muscle region is excluding the border of the mammogram and comparing for both left and right images from the binary image. Further GA is applied to magnify the detected border. The figure of merit is calculated to evaluate whether the detected border is exact or not. And the nipple position is identified using GA. The some comparisons method is adopted for detection of suspected area. Second, using the border points and nipple position as the reference the mammogram images are aligned and subtracted to extract the suspicious region. The algorithms are tested on 114 abnormal digitized mammograms from Mammogram Image Analysis Society database.

  16. Testing novel patient financial incentives to increase breast cancer screening.

    PubMed

    Merrick, Elizabeth Levy; Hodgkin, Dominic; Horgan, Constance M; Lorenz, Laura S; Panas, Lee; Ritter, Grant A; Kasuba, Paul; Poskanzer, Debra; Nefussy, Renee Altman

    2015-11-01

    To examine the effects of 3 types of low-cost financial incentives for patients, including a novel "person-centered" approach on breast cancer screening (mammogram) rates. Randomized controlled trial with 4 arms: 3 types of financial incentives ($15 gift card, entry into lottery for $250 gift card, and a person-centered incentive with choice of $15 gift card or lottery) and a control group. Sample included privately insured Tufts Health Plan members in Massachusetts who were women aged 42 to 69 years with no mammogram claim in ≥ 2.6 years. A sample of 4700 eligible members were randomized to 4 study arms. The control group received a standard reminder letter and the incentive groups received a reminder letter plus an incentive offer for obtaining a mammogram within the next 4 months. Bivariate tests and multivariate logistic regression were used to assess the incentives' impact on mammogram receipt. Data were analyzed for 4427 members (after exclusions such as undeliverable mail). The percent of members receiving a mammogram during the study was 11.7% (gift card), 12.1% (lottery), 13.4% (person-centered/choice), and 11.9% (controls). Differences were not statistically significant in bivariate or multivariate full-sample analyses. In exploratory subgroup analyses of members with a mammogram during the most recent year prior to the study-defined gap, person-centered incentives were associated with a higher likelihood of mammogram receipt. None of the low-cost incentives tested had a statistically significant effect on mammogram rates in the full sample. Exploratory findings for members who were more recently screened suggest that they may be more responsive to person-centered incentives.

  17. Breast Cancer Risk Prediction and Mammography Biopsy Decisions

    PubMed Central

    Armstrong, Katrina; Handorf, Elizabeth A.; Chen, Jinbo; Demeter, Mirar N. Bristol

    2012-01-01

    Background Controversy continues about screening mammography, in part because of the risk of false-negative and false-positive mammograms. Pre-test breast cancer risk factors may improve the positive and negative predictive value of screening. Purpose To create a model that estimates the potential impact of pre-test risk prediction using clinical and genomic information on the reclassification of women with abnormal mammograms (BI-RADS3 and BI-RADS4 [Breast Imaging-Reporting and Data System]) above and below the threshold for breast biopsy. Methods The current study modeled 1-year breast cancer risk in women with abnormal screening mammograms using existing data on breast cancer risk factors, 12 validated breast cancer single nucleotide polymorphisms (SNPs), and probability of cancer given the BI-RADS category. Examination was made of reclassification of women above and below biopsy thresholds of 1%, 2%, and 3% risk. The Breast Cancer Surveillance Consortium data were collected from 1996 to 2002. Data analysis was conducted in 2010 and 2011. Results Using a biopsy risk threshold of 2% and the standard risk factor model, 5% of women with a BI-RADS3 mammogram had a risk above the threshold, and 3% of women with BIRADS4A mammograms had a risk below the threshold. The addition of 12 SNPs in the model resulted in 8% of women with a BI-RADS3 mammogram above the threshold for biopsy and 7% of women with BI-RADS4A mammograms below the threshold. Conclusions The incorporation of pre-test breast cancer risk factors could change biopsy decisions for a small proportion of women with abnormal mammograms. The greatest impact comes from standard breast cancer risk factors. PMID:23253645

  18. Follow-Up of Abnormal Breast and Colorectal Cancer Screening by Race/Ethnicity.

    PubMed

    McCarthy, Anne Marie; Kim, Jane J; Beaber, Elisabeth F; Zheng, Yingye; Burnett-Hartman, Andrea; Chubak, Jessica; Ghai, Nirupa R; McLerran, Dale; Breen, Nancy; Conant, Emily F; Geller, Berta M; Green, Beverly B; Klabunde, Carrie N; Inrig, Stephen; Skinner, Celette Sugg; Quinn, Virginia P; Haas, Jennifer S; Schnall, Mitchell; Rutter, Carolyn M; Barlow, William E; Corley, Douglas A; Armstrong, Katrina; Doubeni, Chyke A

    2016-10-01

    Timely follow-up of abnormal tests is critical to the effectiveness of cancer screening, but may vary by screening test, healthcare system, and sociodemographic group. Timely follow-up of abnormal mammogram and fecal occult blood testing or fecal immunochemical tests (FOBT/FIT) were compared by race/ethnicity using Population-Based Research Optimizing Screening through Personalized Regimens consortium data. Participants were women with an abnormal mammogram (aged 40-75 years) or FOBT/FIT (aged 50-75 years) in 2010-2012. Analyses were performed in 2015. Timely follow-up was defined as colonoscopy ≤3 months following positive FOBT/FIT; additional imaging or biopsy ≤3 months following Breast Imaging Reporting and Data System Category 0, 4, or 5 mammograms; or ≤9 months following Category 3 mammograms. Logistic regression was used to model receipt of timely follow-up adjusting for study site, age, year, insurance, and income. Among 166,602 mammograms, 10.7% were abnormal; among 566,781 FOBT/FITs, 4.3% were abnormal. Nearly 96% of patients with abnormal mammograms received timely follow-up versus 68% with abnormal FOBT/FIT. There was greater variability in receipt of follow-up across healthcare systems for positive FOBT/FIT than for abnormal mammograms. For mammography, black women were less likely than whites to receive timely follow-up (91.8% vs 96.0%, OR=0.71, 95% CI=0.51, 0.97). For FOBT/FIT, Hispanics were more likely than whites to receive timely follow-up than whites (70.0% vs 67.6%, OR=1.12, 95% CI=1.04, 1.21). Timely follow-up among women was more likely for abnormal mammograms than FOBT/FITs, with small variations in follow-up rates by race/ethnicity and larger variation across healthcare systems. Copyright © 2016 American Journal of Preventive Medicine. All rights reserved.

  19. A controlled phantom study of a noise equalization algorithm for detecting microcalcifications in digital mammograms.

    PubMed

    Gürün, O O; Fatouros, P P; Kuhn, G M; de Paredes, E S

    2001-04-01

    We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the approach. Particularly, it was observed that the method of estimating the width of distributions in the feature space was based on assumptions which resulted in the loss of similarity preservation characteristics. A modification involving a change of estimator statistic was made, and the modified approach was tested on the same phantom images. Other modifications for improving detectability such as downsampling and use of alternate local contrast filters were also tested. The results indicate that these modifications yield improvements in detectability, while extending the generality of the approach. Extensions to real mammograms and further directions of research are discussed.

  20. Improved Classification of Mammograms Following Idealized Training

    PubMed Central

    Hornsby, Adam N.; Love, Bradley C.

    2014-01-01

    People often make decisions by stochastically retrieving a small set of relevant memories. This limited retrieval implies that human performance can be improved by training on idealized category distributions (Giguère & Love, 2013). Here, we evaluate whether the benefits of idealized training extend to categorization of real-world stimuli, namely classifying mammograms as normal or tumorous. Participants in the idealized condition were trained exclusively on items that, according to a norming study, were relatively unambiguous. Participants in the actual condition were trained on a representative range of items. Despite being exclusively trained on easy items, idealized-condition participants were more accurate than those in the actual condition when tested on a range of item types. However, idealized participants experienced difficulties when test items were very dissimilar from training cases. The benefits of idealization, attributable to reducing noise arising from cognitive limitations in memory retrieval, suggest ways to improve real-world decision making. PMID:24955325

  1. Improved Classification of Mammograms Following Idealized Training.

    PubMed

    Hornsby, Adam N; Love, Bradley C

    2014-06-01

    People often make decisions by stochastically retrieving a small set of relevant memories. This limited retrieval implies that human performance can be improved by training on idealized category distributions (Giguère & Love, 2013). Here, we evaluate whether the benefits of idealized training extend to categorization of real-world stimuli, namely classifying mammograms as normal or tumorous. Participants in the idealized condition were trained exclusively on items that, according to a norming study, were relatively unambiguous. Participants in the actual condition were trained on a representative range of items. Despite being exclusively trained on easy items, idealized-condition participants were more accurate than those in the actual condition when tested on a range of item types. However, idealized participants experienced difficulties when test items were very dissimilar from training cases. The benefits of idealization, attributable to reducing noise arising from cognitive limitations in memory retrieval, suggest ways to improve real-world decision making.

  2. Evaluation Of Digital Unsharp-Mask Filtering For The Detection Of Subtle Mammographic Microcalcifications

    NASA Astrophysics Data System (ADS)

    Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.

    1986-06-01

    We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted observer performance experiments to evaluate the detectability of micro-calcifications in three sets of mammograms: the original film images, unprocessed digitized images, and unsharp-masked images. Each set included the same 20 normal cases and 12 abnormal cases. A total of 5 board-certified radiologists and 4 senior radiology residents participated as observers. In the first experiment, the detectability of microcalcifications was measured for the original, unprocessed digitized, and unsharp-masked images. Each observer read all 96 films in one session with the cases arranged in a different random order. A maximum of 15 seconds was allowed to read each image. To facilitate receiver operating character-istic (ROC) analysis, each observer ranked his/her observation regarding the presence or absence of a cluster of 3 or more microcalcifications on a 5-point confidence rating scale (1=definitely no microcalcifications, 2=probably no microcalcifications; 3=microcalcifi-cations possibly present; 4=microcalcifications probably present; 5=microcalcifications definitely present). The observer identified the location of the suspected microcalci-fications when the confidence rating was 2 or greater. In the second experiment, we evaluated whether reading the unsharp-masked image and the unprocessed digitized image side by side for each case would reduce false-positive detection rates for microcalcifications and thus improve overall performance. The observer was again allowed a maximum of 15 seconds to read each pair of images and was instructed to use the unsharp-masked image for primary reading and the unprocessed digitized image for reference. The experimental setting and procedures were otherwise the same as those for the first experiment.

  3. Comparative effectiveness of mailed reminder letters on mammography screening compliance.

    PubMed

    Romaire, Melissa A; Bowles, Erin J Aiello; Anderson, Melissa L; Buist, Diana S M

    2012-08-01

    Reminder letters are effective at prompting women to schedule mammograms. Less well studied are reminders addressing multiple preventive service recommendations. We compared the effectiveness of a mammogram-specific reminder sent when a woman was due for a mammogram to a reminder letter addressing multiple preventive services and sent on a woman's birthday on mammography receipt. The study included 48,583 women 52-74 years enrolled in Group Health Cooperative, a health plan in Washington State. From 2005 to 2009, women were mailed 88,605 mammogram-specific or birthday letters. In this one group pretest-posttest study, we modeled the odds of obtaining a screening mammogram after receiving a letter by reminder type using logistic regression, controlling for demographic and healthcare use characteristics and stratifying by whether women were overdue or up-to-date with mammography at the mailing. Among women up-to-date with screening, birthday letters were negatively associated with mammography receipt compared to mammogram-specific letters (birthday letters with 1-2 recommendations: OR=0.73; 95% CI:0.68-0.79; 3 recommendations: OR=0.74; 95% CI:0.69-0.78; 4-8 recommendations: OR=0.62 95% CI:0.55-0.68) after. Among overdue women, birthday letters with 4-8 recommendations were negatively associated with mammography receipt. Transitioning from mammogram-specific reminder letters to multiple preventive service birthday letters was associated with decreased mammography receipt. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Inequity of healthcare utilization on mammography examination and Pap smear screening in Thailand: Analysis of a population-based household survey

    PubMed Central

    2017-01-01

    Healthcare in Thailand is not equally distributed, and not all people can equally access healthcare resources even if they are covered by health insurance. To examine factors associated with the utilization of mammography examination for breast cancer and Pap smear screening for cervical cancer, data from the national reproductive health survey conducted by the National Statistical Office of Thailand in 2009 was examined. The survey was carried out on 15,074,126 women aged 30–59 years. The results showed that the wealthier respondents had more mammograms than did the lower-income groups. The concentration index was 0.144. The data on Pap smears for cervical cancer also showed that the wealthier respondents were more likely to have had a Pap smear than their lower-income counterparts. The concentration index was 0.054. Determinants of mammography examination were education, followed by health welfare and wealth index, whereas the determinants of Pap smear screening were wealth index, followed by health welfare and education. The government should support greater education for women because education was associated with socioeconomic status and wealth. There should be an increase in the number of screening campaigns, mobile clinics, and low-cost mammograms and continued support for accessibility to mammograms, especially in rural areas and low-income communities. PMID:28282430

  5. Computer-aided detection and diagnosis of masses and clustered microcalcifications from digital mammograms

    NASA Astrophysics Data System (ADS)

    Nishikawa, Robert M.; Giger, Maryellen L.; Doi, Kunio; Vyborny, Carl J.; Schmidt, Robert A.; Metz, Charles E.; Wu, Chris Y.; Yin, Fang-Fang; Jiang, Yulei; Huo, Zhimin; Lu, Ping; Zhang, Wei; Ema, Takahiro; Bick, Ulrich; Papaioannou, John; Nagel, Rufus H.

    1993-07-01

    We are developing an 'intelligent' workstation to assist radiologists in diagnosing breast cancer from mammograms. The hardware for the workstation will consist of a film digitizer, a high speed computer, a large volume storage device, a film printer, and 4 high resolution CRT monitors. The software for the workstation is a comprehensive package of automated detection and classification schemes. Two rule-based detection schemes have been developed, one for breast masses and the other for clustered microcalcifications. The sensitivity of both schemes is 85% with a false-positive rate of approximately 3.0 and 1.5 false detections per image, for the mass and cluster detection schemes, respectively. Computerized classification is performed by an artificial neural network (ANN). The ANN has a sensitivity of 100% with a specificity of 60%. Currently, the ANN, which is a three-layer, feed-forward network, requires as input ratings of 14 different radiographic features of the mammogram that were determined subjectively by a radiologist. We are in the process of developing automated techniques to objectively determine these 14 features. The workstation will be placed in the clinical reading area of the radiology department in the near future, where controlled clinical tests will be performed to measure its efficacy.

  6. Acceleration of Image Segmentation Algorithm for (Breast) Mammogram Images Using High-Performance Reconfigurable Dataflow Computers

    PubMed Central

    Filipovic, Nenad D.

    2017-01-01

    Image segmentation is one of the most common procedures in medical imaging applications. It is also a very important task in breast cancer detection. Breast cancer detection procedure based on mammography can be divided into several stages. The first stage is the extraction of the region of interest from a breast image, followed by the identification of suspicious mass regions, their classification, and comparison with the existing image database. It is often the case that already existing image databases have large sets of data whose processing requires a lot of time, and thus the acceleration of each of the processing stages in breast cancer detection is a very important issue. In this paper, the implementation of the already existing algorithm for region-of-interest based image segmentation for mammogram images on High-Performance Reconfigurable Dataflow Computers (HPRDCs) is proposed. As a dataflow engine (DFE) of such HPRDC, Maxeler's acceleration card is used. The experiments for examining the acceleration of that algorithm on the Reconfigurable Dataflow Computers (RDCs) are performed with two types of mammogram images with different resolutions. There were, also, several DFE configurations and each of them gave a different acceleration value of algorithm execution. Those acceleration values are presented and experimental results showed good acceleration. PMID:28611851

  7. Acceleration of Image Segmentation Algorithm for (Breast) Mammogram Images Using High-Performance Reconfigurable Dataflow Computers.

    PubMed

    Milankovic, Ivan L; Mijailovic, Nikola V; Filipovic, Nenad D; Peulic, Aleksandar S

    2017-01-01

    Image segmentation is one of the most common procedures in medical imaging applications. It is also a very important task in breast cancer detection. Breast cancer detection procedure based on mammography can be divided into several stages. The first stage is the extraction of the region of interest from a breast image, followed by the identification of suspicious mass regions, their classification, and comparison with the existing image database. It is often the case that already existing image databases have large sets of data whose processing requires a lot of time, and thus the acceleration of each of the processing stages in breast cancer detection is a very important issue. In this paper, the implementation of the already existing algorithm for region-of-interest based image segmentation for mammogram images on High-Performance Reconfigurable Dataflow Computers (HPRDCs) is proposed. As a dataflow engine (DFE) of such HPRDC, Maxeler's acceleration card is used. The experiments for examining the acceleration of that algorithm on the Reconfigurable Dataflow Computers (RDCs) are performed with two types of mammogram images with different resolutions. There were, also, several DFE configurations and each of them gave a different acceleration value of algorithm execution. Those acceleration values are presented and experimental results showed good acceleration.

  8. Assessment of automatic exposure control performance in digital mammography using a no-reference anisotropic quality index

    NASA Astrophysics Data System (ADS)

    Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.

    2017-03-01

    Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.

  9. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    PubMed Central

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPRfalse-positive rate, sensitivity, and CDRcancer detection rate at all annual interpretive volumes. Conclusion These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow. © RSNA, 2014 Online supplemental material is available for this article. PMID:24960110

  10. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    PubMed

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPR false-positive rate (P = .011) and CDR cancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPR false-positive rate , sensitivity, and CDR cancer detection rate at all annual interpretive volumes. These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow.

  11. Mammogram segmentation using maximal cell strength updation in cellular automata.

    PubMed

    Anitha, J; Peter, J Dinesh

    2015-08-01

    Breast cancer is the most frequently diagnosed type of cancer among women. Mammogram is one of the most effective tools for early detection of the breast cancer. Various computer-aided systems have been introduced to detect the breast cancer from mammogram images. In a computer-aided diagnosis system, detection and segmentation of breast masses from the background tissues is an important issue. In this paper, an automatic segmentation method is proposed to identify and segment the suspicious mass regions of mammogram using a modified transition rule named maximal cell strength updation in cellular automata (CA). In coarse-level segmentation, the proposed method performs an adaptive global thresholding based on the histogram peak analysis to obtain the rough region of interest. An automatic seed point selection is proposed using gray-level co-occurrence matrix-based sum average feature in the coarse segmented image. Finally, the method utilizes CA with the identified initial seed point and the modified transition rule to segment the mass region. The proposed approach is evaluated over the dataset of 70 mammograms with mass from mini-MIAS database. Experimental results show that the proposed approach yields promising results to segment the mass region in the mammograms with the sensitivity of 92.25% and accuracy of 93.48%.

  12. Predictors and patterns of fear of cancer recurrence in breast cancer survivors.

    PubMed

    McGinty, Heather L; Small, Brent J; Laronga, Christine; Jacobsen, Paul B

    2016-01-01

    This prospective, longitudinal study examined fear of cancer recurrence (FCR) among breast cancer survivors having mammograms. FCR was hypothesized to increase prior to the mammogram, decrease from immediately pre- to immediately post-mammogram with negative results, and then increase following the mammogram. The possible presence of different trajectories of FCR was also examined. Based on the cognitive-behavioral model (CBM) of health anxiety, greater perceived risk of recurrence, worse perceived consequences of recurrence, lower treatment efficacy beliefs, lower coping self-efficacy, and more engagement in reassurance-seeking behaviors were hypothesized to be associated with greater FCR across all study time points. Following treatment completion for Stage 0-IIIA breast cancer, 161 women completed the following measures: perceived risk and perceived consequences of recurrence, treatment efficacy beliefs, coping self-efficacy, and reassurance-seeking behaviors. Participants reported FCR at 3 time points before and 3 after the mammogram. Growth curve analysis was used to test for changes in FCR over time and growth mixture modeling examined different trajectories in FCR and the ability of the CBM to predict these trajectories. As hypothesized, FCR significantly changed over time; scores increased prior to the mammogram, decreased immediately following receipt of negative mammography results, and increased during the month following the mammogram. Growth mixture models revealed 2 classes, higher-FCR and lower-FCR, which were predicted by the CBM. These study findings support the use of the CBM in predicting which cancer survivors experience greater FCR and indicates that CBM-driven interventions may prove beneficial for reducing distressing FCR. (c) 2015 APA, all rights reserved).

  13. Depression and anxiety diagnoses are not associated with delayed resolution of abnormal mammograms and pap tests among vulnerable women.

    PubMed

    Kronman, Andrea C; Freund, Karen M; Heeren, Tim; Beaver, Kristine A; Flynn, Mary; Battaglia, Tracy A

    2012-04-01

    Delays in care after abnormal cancer screening contribute to disparities in cancer outcomes. Women with psychiatric disorders are less likely to receive cancer screening and may also have delays in diagnostic resolution after an abnormal screening test. To determine if depression and anxiety are associated with delays in resolution after abnormal mammograms and Pap tests in a vulnerable population of urban women. We conducted retrospective chart reviews of electronic medical records to identify women who had a diagnosis of depression or anxiety in the year prior to the abnormal mammogram or Pap test. We used time-to-event analysis to analyze the outcome of time to resolution after abnormal cancer screening, and Cox proportional hazards regression modeling to control for confounding. Women receiving care in six Boston-area community health centers 2004-2005: 523 with abnormal mammograms, 474 with abnormal Pap tests. Of the women with abnormal mammogram and pap tests, 19% and 16%, respectively, had co-morbid depression. There was no difference in time to diagnostic resolution between depressed and not-depressed women for those with abnormal mammograms (aHR = 0.9, 95 CI 0.7,1.1) or Pap tests (aHR = 0.9, 95 CI 0.7,1.3). An active diagnosis of depression and/or anxiety in the year prior to an abnormal mammogram or Pap test was not associated with a prolonged time to diagnostic resolution. Our findings imply that documented mood disorders do not identify an additional barrier to resolution after abnormal cancer screening in a vulnerable population of women.

  14. Mammograms

    MedlinePlus

    ... mammography facility know about breast implants when scheduling a mammogram. The technologist and radiologist must be experienced in performing mammography on women who have breast implants. If the technologist ...

  15. Advanced Signal Processing Methods Applied to Digital Mammography

    NASA Technical Reports Server (NTRS)

    Stauduhar, Richard P.

    1997-01-01

    The work reported here is on the extension of the earlier proposal of the same title, August 1994-June 1996. The report for that work is also being submitted. The work reported there forms the foundation for this work from January 1997 to September 1997. After the earlier work was completed there were a few items that needed to be completed prior to submission of a new and more comprehensive proposal for further research. Those tasks have been completed and two new proposals have been submitted, one to NASA, and one to Health & Human Services WS). The main purpose of this extension was to refine some of the techniques that lead to automatic large scale evaluation of full mammograms. Progress on each of the proposed tasks follows. Task 1: A multiresolution segmentation of background from breast has been developed and tested. The method is based on the different noise characteristics of the two different fields. The breast field has more power in the lower octaves and the off-breast field behaves similar to a wideband process, where more power is in the high frequency octaves. After the two fields are separated by lowpass filtering, a region labeling routine is used to find the largest contiguous region, the breast. Task 2: A wavelet expansion that can decompose the image without zero padding has been developed. The method preserves all properties of the power-of-two wavelet transform and does not add appreciably to computation time or storage. This work is essential for analysis of the full mammogram, as opposed to selecting sections from the full mammogram. Task 3: A clustering method has been developed based on a simple counting mechanism. No ROC analysis has been performed (and was not proposed), so we cannot finally evaluate this work without further support. Task 4: Further testing of the filter reveals that different wavelet bases do yield slightly different qualitative results. We cannot provide quantitative conclusions about this for all possible bases without further support. Task 5: Better modeling does indeed make an improvement in the detection output. After the proposal ended, we came up with some new theoretical explanations that helps in understanding when the D4 filter should be better. This work is currently in the review process. Task 6: N/A. This no longer applies in view of Tasks 4-5. Task 7: Comprehensive plans for further work have been completed. These plans are the subject of two proposals, one to NASA and one to HHS. These proposals represent plans for a complete evaluation of the methods for identifying normal mammograms, augmented with significant further theoretical work.

  16. Mammogram

    MedlinePlus

    Mammography; Breast cancer - mammography; Breast cancer - screening mammography; Breast lump - mammogram; Breast tomosynthesis ... images. This does not always mean you have breast cancer. Your health care provider may simply need to ...

  17. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borges, Lucas R., E-mail: lucas.rodrigues.borges@usp.br; Oliveira, Helder C. R. de; Nunes, Polyana F.

    2016-06-15

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtainedmore » by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.« less

  18. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    PubMed Central

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Bakic, Predrag R.; Maidment, Andrew D. A.; Vieira, Marcelo A. C.

    2016-01-01

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions. PMID:27277017

  19. Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms

    PubMed Central

    Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish

    2014-01-01

    Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224

  20. The Immediate Impact of the 2009 USPSTF Screening Guideline Change on Physician Recommendation of a Screening Mammogram: Findings from a National Ambulatory and Medical Care Survey-Based Study.

    PubMed

    Rajan, Suja S; Suryavanshi, Manasi S; Karanth, Siddharth; Lairson, David R

    2017-04-01

    Regular screening is considered the most effective method to reduce the mortality and morbidity associated with breast cancer. Nevertheless, contradictory evidence about screening mammograms has led to periodic changes and considerable variations among different screening guidelines. This study is the first to examine the immediate impact of the 2009 US Preventive Services Task Force (USPSTF) guideline modification on physician recommendation of mammograms. The study included visits by women aged 40 years and older without prior breast cancer from the National Ambulatory and Medical Care Survey 2008-2010. Bivariate and multiple logistic regressions were used to determine the factors associated with mammography recommendation. Approximately 29,395 visits were included and mammography was recommended during 1350 visits; 50-64-year-old women had 72% higher odds, and 65-74-year-old women had twice the odds of getting a mammogram recommendation compared with 40-49-year-old women in 2009. However, there was no difference in recommendation by age groups in 2008 and 2010. Obstetricians and gynecologists did not modify their recommendation behavior in 2009, unlike all other specialists who reduced their recommendation for 40-49-year-old women in 2009. Other characteristics associated with mammogram recommendations were certain patient comorbidities, physician specialty and primary care physician status, health maintenance organization status of the clinic, and certain visit characteristics. This study demonstrated a temporary effect of the USPSTF screening guideline change on mammogram recommendation. However, in light of conflicting recommendations by different guidelines, the physicians erred toward the more rigorous guidelines and did not permanently reduce their mammogram recommendation for women aged 40-49 years.

  1. A breast health educational program for Chinese-American women: 3- to 12-month postintervention effect.

    PubMed

    Lee-Lin, Frances; Nguyen, Thuan; Pedhiwala, Nisreen; Dieckmann, Nathan; Menon, Usha

    2015-01-01

    To test the efficacy of a culturally targeted breast cancer screening educational program in increasing mammogram completion in Chinese-American immigrant women. Randomized controlled study. Chinese communities, Portland, Oregon. From April 2010 to September 2011, 300 women were randomized to receive a theory-based, culturally targeted breast cancer screening educational intervention (n = 147) or a mammography screening brochure published by the National Cancer Institute (n = 153). The two-part intervention consisted of group teaching with targeted, theory-based messages followed by individual counseling sessions. Mammography completion, perceived susceptibility, perceived benefits, perceived barriers, perceived cultural barriers, and demographic variables. A 2 × 3 mixed logistic model was applied to determine odds ratio of mammogram completion. Behavior changed in both groups, with a total of 170 participants (56.7%) reporting a mammogram at 12 months. The logistic model indicated increased odds of mammogram completion in the intervention compared to the control group at 3, 6, and 12 months. When controlling for marital status, age, and age moved to the United States, the intervention group was nine times more likely to complete mammograms than the control group. The culturally targeted educational program significantly increased mammogram use among Chinese immigrant women. Further testing of effectiveness in larger community settings is needed. The intervention may also serve as a foundation from which to develop education to increase cancer screening among other minority subgroups.

  2. Perceptions of One's Neighborhood and Mammogram Use among a Sample of Low-Income Women at Risk for Human Immunodeficiency Virus and Sexually Transmitted Infections.

    PubMed

    Davey-Rothwell, Melissa A; Bowie, Janice; Murray, Laura; Latkin, Carl A

    2016-01-01

    Neighborhood disorder, signs of physical and social disorganization, has been related to a range of poor mental and physical health outcomes. Although individual factors have been widely associated with getting a mammogram, little is known about the impact of the neighborhood environment on a woman's decision to get a mammogram. In a sample of women at risk for human immunodeficiency virus and sexually transmitted infections, we explored the role of perceptions of one's neighborhood on getting a mammogram. The study included two samples: women 40 to 49 years (n = 233) and women 50 years and older (n = 83). Data were collected from May 2006 through June 2008. Women age 50 years and older who lived in a neighborhood with disorder were 72% less likely to get a mammogram compared with women who lived in neighborhoods without disorder. There was no relationship for women age 40 to 49 years. Interventions are needed to increase awareness and encourage women living in neighborhoods with disorder to get a mammogram. In addition to interventions to increase mammography, programs are needed to decrease neighborhood disorder. Increasing neighborhood cohesion, social control, and empowerment could integrate health promotion programs to both reduce disorder and increase health behaviors. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  3. New Embedded Denotes Fuzzy C-Mean Application for Breast Cancer Density Segmentation in Digital Mammograms

    NASA Astrophysics Data System (ADS)

    Othman, Khairulnizam; Ahmad, Afandi

    2016-11-01

    In this research we explore the application of normalize denoted new techniques in advance fast c-mean in to the problem of finding the segment of different breast tissue regions in mammograms. The goal of the segmentation algorithm is to see if new denotes fuzzy c- mean algorithm could separate different densities for the different breast patterns. The new density segmentation is applied with multi-selection of seeds label to provide the hard constraint, whereas the seeds labels are selected based on user defined. New denotes fuzzy c- mean have been explored on images of various imaging modalities but not on huge format digital mammograms just yet. Therefore, this project is mainly focused on using normalize denoted new techniques employed in fuzzy c-mean to perform segmentation to increase visibility of different breast densities in mammography images. Segmentation of the mammogram into different mammographic densities is useful for risk assessment and quantitative evaluation of density changes. Our proposed methodology for the segmentation of mammograms on the basis of their region into different densities based categories has been tested on MIAS database and Trueta Database.

  4. Segmentation for the enhancement of microcalcifications in digital mammograms.

    PubMed

    Milosevic, Marina; Jankovic, Dragan; Peulic, Aleksandar

    2014-01-01

    Microcalcification clusters appear as groups of small, bright particles with arbitrary shapes on mammographic images. They are the earliest sign of breast carcinomas and their detection is the key for improving breast cancer prognosis. But due to the low contrast of microcalcifications and same properties as noise, it is difficult to detect microcalcification. This work is devoted to developing a system for the detection of microcalcification in digital mammograms. After removing noise from mammogram using the Discrete Wavelet Transformation (DWT), we first selected the region of interest (ROI) in order to demarcate the breast region on a mammogram. Segmenting region of interest represents one of the most important stages of mammogram processing procedure. The proposed segmentation method is based on a filtering using the Sobel filter. This process will identify the significant pixels, that belong to edges of microcalcifications. Microcalcifications were detected by increasing the contrast of the images obtained by applying Sobel operator. In order to confirm the effectiveness of this microcalcification segmentation method, the Support Vector Machine (SVM) and k-Nearest Neighborhood (k-NN) algorithm are employed for the classification task using cross-validation technique.

  5. Quantification of mammographic masking risk with volumetric breast density maps: how to select women for supplemental screening

    NASA Astrophysics Data System (ADS)

    Holland, Katharina; van Gils, Carla H.; Wanders, Johanna OP; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    The sensitivity of mammograms is low for women with dense breasts, since cancers may be masked by dense tissue. In this study, we investigated methods to identify women with density patterns associated with a high masking risk. Risk measures are derived from volumetric breast density maps. We used the last negative screening mammograms of 93 women who subsequently presented with an interval cancer (IC), and, as controls, 930 randomly selected normal screening exams from women without cancer. Volumetric breast density maps were computed from the mammograms, which provide the dense tissue thickness at each location. These were used to compute absolute and percentage glandular tissue volume. We modeled the masking risk for each pixel location using the absolute and percentage dense tissue thickness and we investigated the effect of taking the cancer location probability distribution (CLPD) into account. For each method, we selected cases with the highest masking measure (by thresholding) and computed the fraction of ICs as a function of the fraction of controls selected. The latter can be interpreted as the negative supplemental screening rate (NSSR). Between the models, when incorporating CLPD, no significant differences were found. In general, the methods performed better when CLPD was included. At higher NSSRs some of the investigated masking measures had a significantly higher performance than volumetric breast density. These measures may therefore serve as an alternative to identify women with a high risk for a masked cancer.

  6. Local breast density assessment using reacquired mammographic images.

    PubMed

    García, Eloy; Diaz, Oliver; Martí, Robert; Diez, Yago; Gubern-Mérida, Albert; Sentís, Melcior; Martí, Joan; Oliver, Arnau

    2017-08-01

    The aim of this paper is to evaluate the spatial glandular volumetric tissue distribution as well as the density measures provided by Volpara™ using a dataset composed of repeated pairs of mammograms, where each pair was acquired in a short time frame and in a slightly changed position of the breast. We conducted a retrospective analysis of 99 pairs of repeatedly acquired full-field digital mammograms from 99 different patients. The commercial software Volpara™ Density Maps (Volpara Solutions, Wellington, New Zealand) is used to estimate both the global and the local glandular tissue distribution in each image. The global measures provided by Volpara™, such as breast volume, volume of glandular tissue, and volumetric breast density are compared between the two acquisitions. The evaluation of the local glandular information is performed using histogram similarity metrics, such as intersection and correlation, and local measures, such as statistics from the difference image and local gradient correlation measures. Global measures showed a high correlation (breast volume R=0.99, volume of glandular tissue R=0.94, and volumetric breast density R=0.96) regardless the anode/filter material. Similarly, histogram intersection and correlation metric showed that, for each pair, the images share a high degree of information. Regarding the local distribution of glandular tissue, small changes in the angle of view do not yield significant differences in the glandular pattern, whilst changes in the breast thickness between both acquisition affect the spatial parenchymal distribution. This study indicates that Volpara™ Density Maps is reliable in estimating the local glandular tissue distribution and can be used for its assessment and follow-up. Volpara™ Density Maps is robust to small variations of the acquisition angle and to the beam energy, although divergences arise due to different breast compression conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Evaluation of a New Ensemble Learning Framework for Mass Classification in Mammograms.

    PubMed

    Rahmani Seryasat, Omid; Haddadnia, Javad

    2018-06-01

    Mammography is the most common screening method for diagnosis of breast cancer. In this study, a computer-aided system for diagnosis of benignity and malignity of the masses was implemented in mammogram images. In the computer aided diagnosis system, we first reduce the noise in the mammograms using an effective noise removal technique. After the noise removal, the mass in the region of interest must be segmented and this segmentation is done using a deformable model. After the mass segmentation, a number of features are extracted from it. These features include: features of the mass shape and border, tissue properties, and the fractal dimension. After extracting a large number of features, a proper subset must be chosen from among them. In this study, we make use of a new method on the basis of a genetic algorithm for selection of a proper set of features. After determining the proper features, a classifier is trained. To classify the samples, a new architecture for combination of the classifiers is proposed. In this architecture, easy and difficult samples are identified and trained using different classifiers. Finally, the proposed mass diagnosis system was also tested on mini-Mammographic Image Analysis Society and digital database for screening mammography databases. The obtained results indicate that the proposed system can compete with the state-of-the-art methods in terms of accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Performance of a fail-safe system to follow up abnormal mammograms in primary care.

    PubMed

    Grossman, Ellie; Phillips, Russell S; Weingart, Saul N

    2010-09-01

    Missed and delayed breast cancer diagnoses are major sources of potential harm to patients and medical malpractice liability in the United States. Follow-up of abnormal mammogram results is an essential but challenging component of safe breast care. To explore the value of an inexpensive method to follow up abnormal test results, we examined a paper-based fail-safe system. We examined a fail-safe system used to follow up abnormal mammograms at a primary care practice at an urban teaching hospital. We analyzed all abnormal mammogram reports and clinicians' responses to follow-up reminders. We characterized potential lapses identified in this system and used regression models to identify patient, provider, and test result characteristics associated with such lapses. Clinicians responded to fail-safe reminders for 92% of 948 abnormal mammograms. Clinicians reported that they were unaware of the abnormal result in 8% of cases and that there was no follow-up plan in place for 3% of cases. Clinicians with more years of experience were more likely to be aware of the abnormal result (odds of being unaware per incremental year in practice, 0.92; 95% confidence interval, 0.88-0.97) and were more likely to have a follow-up plan. A paper-based fail-safe system for abnormal mammograms is feasible in a primary care practice. However, special care is warranted to ensure full clinician adherence and address staff transitions and trainee-related issues.

  9. INDIAM--an e-learning system for the interpretation of mammograms.

    PubMed

    Guliato, Denise; Bôaventura, Ricardo S; Maia, Marcelo A; Rangayyan, Rangaraj M; Simedo, Mariângela S; Macedo, Túlio A A

    2009-08-01

    We propose the design of a teaching system named Interpretation and Diagnosis of Mammograms (INDIAM) for training students in the interpretation of mammograms and diagnosis of breast cancer. The proposed system integrates an illustrated tutorial on radiology of the breast, that is, mammography, which uses education techniques to guide the user (doctors, students, or researchers) through various concepts related to the diagnosis of breast cancer. The user can obtain informative text about specific subjects, access a library of bibliographic references, and retrieve cases from a mammographic database that are similar to a query case on hand. The information of each case stored in the mammographic database includes the radiological findings, the clinical history, the lifestyle of the patient, and complementary exams. The breast cancer tutorial is linked to a module that simulates the analysis and diagnosis of a mammogram. The tutorial incorporates tools for helping the user to evaluate his or her knowledge about a specific subject by using the education system or by simulating a diagnosis with appropriate feedback in case of error. The system also makes available digital image processing tools that allow the user to draw the contour of a lesion, the contour of the breast, or identify a cluster of calcifications in a given mammogram. The contours provided by the user are submitted to the system for evaluation. The teaching system is integrated with AMDI-An Indexed Atlas of Digital Mammograms-that includes case studies, e-learning, and research systems. All the resources are accessible via the Web.

  10. The personal costs and convenience of screening mammography.

    PubMed

    Suter, Lisa Gale; Nakano, Connie Y; Elmore, Joann G

    2002-09-01

    Few studies have examined the impact of women's personal costs on obtaining a screening mammogram in the United States. All women obtaining screening mammograms at nine Connecticut mammography facilities during a 2-week study period were asked to complete a questionnaire. Facilities included urban and rural fixed sites and mobile sites. The survey included questions about insurance coverage, mammogram payment, and personal costs in terms of transportation, family care, parking, and lost work time from the women's perspective. The response rate was 62% (731 of 1189). Thirty-two percent of respondents incurred some type of personal cost, including lost work time, family care, and parking. Women incurring personal costs were more likely than those without personal costs to attend an urban facility (46% vs. 23%, p < 0.01) and be under the age of 50 (40% vs. 26%, p < 0.01). Overall, 61% of women listed convenience and 17% listed cost as a reason for choosing a mammography facility; 23% reported that cost might prevent them from obtaining a future mammogram. One third of women obtaining mammograms may be incurring personal costs. These personal costs should be considered in future cost-effectiveness analyses.

  11. Breast cancer risk assessment and diagnosis model using fuzzy support vector machine based expert system

    NASA Astrophysics Data System (ADS)

    Dheeba, J.; Jaya, T.; Singh, N. Albert

    2017-09-01

    Classification of cancerous masses is a challenging task in many computerised detection systems. Cancerous masses are difficult to detect because these masses are obscured and subtle in mammograms. This paper investigates an intelligent classifier - fuzzy support vector machine (FSVM) applied to classify the tissues containing masses on mammograms for breast cancer diagnosis. The algorithm utilises texture features extracted using Laws texture energy measures and a FSVM to classify the suspicious masses. The new FSVM treats every feature as both normal and abnormal samples, but with different membership. By this way, the new FSVM have more generalisation ability to classify the masses in mammograms. The classifier analysed 219 clinical mammograms collected from breast cancer screening laboratory. The tests made on the real clinical mammograms shows that the proposed detection system has better discriminating power than the conventional support vector machine. With the best combination of FSVM and Laws texture features, the area under the Receiver operating characteristic curve reached .95, which corresponds to a sensitivity of 93.27% with a specificity of 87.17%. The results suggest that detecting masses using FSVM contribute to computer-aided detection of breast cancer and as a decision support system for radiologists.

  12. Response of deep and shallow tropical maritime cumuli to large-scale processes

    NASA Technical Reports Server (NTRS)

    Yanai, M.; Chu, J.-H.; Stark, T. E.; Nitta, T.

    1976-01-01

    The bulk diagnostic method of Yanai et al. (1973) and a simplified version of the spectral diagnostic method of Nitta (1975) are used for a more quantitative evaluation of the response of various types of cumuliform clouds to large-scale processes, using the same data set in the Marshall Islands area for a 100-day period in 1956. The dependence of the cloud mass flux distribution on radiative cooling, large-scale vertical motion, and evaporation from the sea is examined. It is shown that typical radiative cooling rates in the tropics tend to produce a bimodal distribution of mass spectrum exhibiting deep and shallow clouds. The bimodal distribution is further enhanced when the large-scale vertical motion is upward, and a nearly unimodal distribution of shallow clouds prevails when the relative cooling is compensated by the heating due to the large-scale subsidence. Both deep and shallow clouds are modulated by large-scale disturbances. The primary role of surface evaporation is to maintain the moisture flux at the cloud base.

  13. Breast Cancers Between Mammograms Have Aggressive Features

    Cancer.gov

    Breast cancers that are discovered in the period between regular screening mammograms—known as interval cancers—are more likely to have features associated with aggressive behavior and a poor prognosis than cancers found via screening mammograms.

  14. Segmentation and detection of breast cancer in mammograms combining wavelet analysis and genetic algorithm.

    PubMed

    Pereira, Danilo Cesar; Ramos, Rodrigo Pereira; do Nascimento, Marcelo Zanchetta

    2014-04-01

    In Brazil, the National Cancer Institute (INCA) reports more than 50,000 new cases of the disease, with risk of 51 cases per 100,000 women. Radiographic images obtained from mammography equipments are one of the most frequently used techniques for helping in early diagnosis. Due to factors related to cost and professional experience, in the last two decades computer systems to support detection (Computer-Aided Detection - CADe) and diagnosis (Computer-Aided Diagnosis - CADx) have been developed in order to assist experts in detection of abnormalities in their initial stages. Despite the large number of researches on CADe and CADx systems, there is still a need for improved computerized methods. Nowadays, there is a growing concern with the sensitivity and reliability of abnormalities diagnosis in both views of breast mammographic images, namely cranio-caudal (CC) and medio-lateral oblique (MLO). This paper presents a set of computational tools to aid segmentation and detection of mammograms that contained mass or masses in CC and MLO views. An artifact removal algorithm is first implemented followed by an image denoising and gray-level enhancement method based on wavelet transform and Wiener filter. Finally, a method for detection and segmentation of masses using multiple thresholding, wavelet transform and genetic algorithm is employed in mammograms which were randomly selected from the Digital Database for Screening Mammography (DDSM). The developed computer method was quantitatively evaluated using the area overlap metric (AOM). The mean ± standard deviation value of AOM for the proposed method was 79.2 ± 8%. The experiments demonstrate that the proposed method has a strong potential to be used as the basis for mammogram mass segmentation in CC and MLO views. Another important aspect is that the method overcomes the limitation of analyzing only CC and MLO views. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Tumor Size of Invasive Breast Cancer on Magnetic Resonance Imaging and Conventional Imaging (Mammogram/Ultrasound): Comparison with Pathological Size and Clinical Implications.

    PubMed

    Haraldsdóttir, K H; Jónsson, Þ; Halldórsdóttir, A B; Tranberg, K-G; Ásgeirsson, K S

    2017-03-01

    In Landspitali University Hospital, magnetic resonance imaging is used non-selectively in addition to mammogram and ultrasound in the preoperative assessment of breast cancer patients. The aim of this study was to assess invasive tumor size on imaging, compare with pathological size and evaluate the impact of magnetic resonance imaging on the type of surgery performed. All women with invasive breast cancer, diagnosed in Iceland, between 2007 and 2009 were reviewed retrospectively. In all, 438 of 641 (68%) patients diagnosed had preoperative magnetic resonance imaging. Twelve patients treated with neoadjuvant chemotherapy were excluded and 65 patients with multifocal or contralateral disease were assessed separately. Correlations between microscopic and radiologic tumor sizes were relatively weak. All imaging methods were inaccurate especially for large tumors, resulting in an overall underestimation of tumor size for these tumors. Magnetic resonance imaging under- and overestimated pathological tumor size by more than 10 mm in 16/348 (4.6%) and 26/348 patients (7.5%), respectively. In 19 patients (73%), overestimation of size was seen exclusively on magnetic resonance imaging. For tumors under- or overestimated by magnetic resonance imaging, the mastectomy rates were 56% and 65%, respectively, compared to an overall mastectomy rate of 43%. Of 51 patients diagnosed with multifocal disease on pathology, 19 (37%) were diagnosed by mammogram or ultrasound and 40 (78%) by magnetic resonance imaging resulting in a total detection rate of 84% (43 patients). Fourteen (3%) patients were diagnosed preoperatively with contralateral disease. Of those tumors, all were detected on magnetic resonance imaging but seven (50%) were also detected on mammogram or ultrasound or both. Our results suggest that routine use of magnetic resonance imaging may result in both under- and overestimation of tumor size and increase mastectomy rates in a small proportion of patients. Magnetic resonance imaging aids in the diagnosis of contralateral and multifocal disease.

  16. Impact of Immediate Interpretation of Screening Tomosynthesis Mammography on Performance Metrics.

    PubMed

    Winkler, Nicole S; Freer, Phoebe; Anzai, Yoshimi; Hu, Nan; Stein, Matthew

    2018-05-07

    This study aimed to compare performance metrics for immediate and delayed batch interpretation of screening tomosynthesis mammograms. This HIPAA compliant study was approved by institutional review board with a waiver of consent. A retrospective analysis of screening performance metrics for tomosynthesis mammograms interpreted in 2015 when mammograms were read immediately was compared to historical controls from 2013 to 2014 when mammograms were batch interpreted after the patient had departed. A total of 5518 screening tomosynthesis mammograms (n = 1212 for batch interpretation and n = 4306 for immediate interpretation) were evaluated. The larger sample size for the latter group reflects a group practice shift to performing tomosynthesis for the majority of patients. Age, breast density, comparison examinations, and high-risk status were compared. An asymptotic proportion test and multivariable analysis were used to compare performance metrics. There was no statistically significant difference in recall or cancer detection rates for the batch interpretation group compared to immediate interpretation group with respective recall rate of 6.5% vs 5.3% = +1.2% (95% confidence interval -0.3 to 2.7%; P = .101) and cancer detection rate of 6.6 vs 7.2 per thousand = -0.6 (95% confidence interval -5.9 to 4.6; P = .825). There was no statistically significant difference in positive predictive values (PPVs) including PPV1 (screening recall), PPV2 (biopsy recommendation), or PPV 3 (biopsy performed) with batch interpretation (10.1%, 42.1%, and 40.0%, respectively) and immediate interpretation (13.6%, 39.2%, and 39.7%, respectively). After adjusting for age, breast density, high-risk status, and comparison mammogram, there was no difference in the odds of being recalled or cancer detection between the two groups. There is no statistically significant difference in interpretation performance metrics for screening tomosynthesis mammograms interpreted immediately compared to those interpreted in a delayed fashion. Copyright © 2018. Published by Elsevier Inc.

  17. Mammography decision making: Trends and predictors of provider communication in the Health Information National Trends Survey, 2011 to 2014.

    PubMed

    Spring, Laura M; Marshall, Megan R; Warner, Erica T

    2017-02-01

    In 2009, the US Preventive Services Task Force recommended that the decision to initiate screening mammography before age 50 years should be individualized. Herein, the authors examined whether health care providers are communicating regarding mammography decision making with women and whether communication is associated with screening behavior. Data were drawn from the 2011 to 2014 Health Information National Trends Survey (HINTS). A total of 5915 female respondents aged ≥ 40 years who responded to the following question were included: "Has a doctor or other health professional ever told you that you could choose whether or not to have a mammogram?" We used logistic regression to generate odds ratios (ORs) and 95% confidence intervals (95% CIs) for predictors of provider communication and assessed whether provider communication was associated with mammography in the previous 2 years overall and stratified by age. Fewer than 50% of the women reported provider communication regarding mammogram choice. Women who reported provider communication were not found to be more likely to report no mammogram within the past 2 years (OR, 1.07; 95% CI, 0.87-1.31) compared with those who did not. When stratified by 10-year age group, provider communication was associated with a higher likelihood of no mammogram only among women age ≥70 years (OR, 1.64; 95% CI, 1.15-2.34), and was associated with a lower likelihood of no mammogram only among women aged 40 to 49 years (OR, 0.63; 95% CI, 0.43-0.92). Between 2011 and 2014, less than one-half of women received communication regarding mammogram choice despite recommendations from the US Preventive Services Task Force. Provider communication regarding mammogram choice can influence screening behavior, particularly for younger and older women. Cancer 2017;123:401-409. © 2016 American Cancer Society. © 2016 American Cancer Society.

  18. Automatic correspondence detection in mammogram and breast tomosynthesis images

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Jan; Krüger, Julia; Bischof, Arpad; Barkhausen, Jörg; Handels, Heinz

    2012-02-01

    Two-dimensional mammography is the major imaging modality in breast cancer detection. A disadvantage of mammography is the projective nature of this imaging technique. Tomosynthesis is an attractive modality with the potential to combine the high contrast and high resolution of digital mammography with the advantages of 3D imaging. In order to facilitate diagnostics and treatment in the current clinical work-flow, correspondences between tomosynthesis images and previous mammographic exams of the same women have to be determined. In this paper, we propose a method to detect correspondences in 2D mammograms and 3D tomosynthesis images automatically. In general, this 2D/3D correspondence problem is ill-posed, because a point in the 2D mammogram corresponds to a line in the 3D tomosynthesis image. The goal of our method is to detect the "most probable" 3D position in the tomosynthesis images corresponding to a selected point in the 2D mammogram. We present two alternative approaches to solve this 2D/3D correspondence problem: a 2D/3D registration method and a 2D/2D mapping between mammogram and tomosynthesis projection images with a following back projection. The advantages and limitations of both approaches are discussed and the performance of the methods is evaluated qualitatively and quantitatively using a software phantom and clinical breast image data. Although the proposed 2D/3D registration method can compensate for moderate breast deformations caused by different breast compressions, this approach is not suitable for clinical tomosynthesis data due to the limited resolution and blurring effects perpendicular to the direction of projection. The quantitative results show that the proposed 2D/2D mapping method is capable of detecting corresponding positions in mammograms and tomosynthesis images automatically for 61 out of 65 landmarks. The proposed method can facilitate diagnosis, visual inspection and comparison of 2D mammograms and 3D tomosynthesis images for the physician.

  19. What Is a Mammogram and When Should I Get One?

    MedlinePlus

    ... Statistics What CDC Is Doing Research African American Women and Mass Media Campaign Public Service Announcements Print Materials Buttons and Badges Stay Informed Cancer Home What Is a Mammogram? Language: English (US) Español ( ...

  20. Automated detection of microcalcification clusters in mammograms

    NASA Astrophysics Data System (ADS)

    Karale, Vikrant A.; Mukhopadhyay, Sudipta; Singh, Tulika; Khandelwal, Niranjan; Sadhu, Anup

    2017-03-01

    Mammography is the most efficient modality for detection of breast cancer at early stage. Microcalcifications are tiny bright spots in mammograms and can often get missed by the radiologist during diagnosis. The presence of microcalcification clusters in mammograms can act as an early sign of breast cancer. This paper presents a completely automated computer-aided detection (CAD) system for detection of microcalcification clusters in mammograms. Unsharp masking is used as a preprocessing step which enhances the contrast between microcalcifications and the background. The preprocessed image is thresholded and various shape and intensity based features are extracted. Support vector machine (SVM) classifier is used to reduce the false positives while preserving the true microcalcification clusters. The proposed technique is applied on two different databases i.e DDSM and private database. The proposed technique shows good sensitivity with moderate false positives (FPs) per image on both databases.

  1. Assessment of Mammography Experiences and Satisfaction among American Indian/Alaska Native Women

    PubMed Central

    Ndikum-Moffor, Florence M.; Braiuca, Stacy; Daley, Christine Makosky; Gajewski, Byron J.; Engelman, Kimberly K.

    2013-01-01

    BACKGROUND American Indian/Alaska Native (AI/AN) women have lower breast cancer (BCA) screening and 5-year survival rates than non-Hispanic Whites. Understanding reasons for low screening rates is important to combat later stage diagnoses. The purpose of this study was to assess mammography experiences and satisfaction among AI/AN women. METHODS Nine focus groups were held with rural (N=15) and urban (N=38) AI/AN women 40 years and older in Kansas and Kansas City, Missouri, living both near and far from Indian Health Service (IHS) and tribal facilities, to examine experiences and satisfaction with mammography. Transcripts were coded and themes identified using a community-based participatory research approach. FINDINGS Themes were classified under knowledge, communication, and awareness of breast cancer, barriers to mammography, mammogram facility size, impressions of mammogram technologist, motivations to getting a mammogram, and how to improve the mammogram experience. Participants had knowledge of prevention, but described cultural reasons for not discussing it and described better experiences in smaller facilities. Participants indicated having a mammogram technologist who was friendly, knowledgeable, respectful, competent, and explained the test was a determining factor in satisfaction. Other factors included family history, physician recommendation, and financial incentives. Barriers included transportation, cost, perceptions of prejudice, and time constraints. Participants on reservations or near IHS facilities preferred IHS over mainstream providers. Suggestions for improvement included caring technologists, better machines with less discomfort, and education. CONCLUSIONS Interventions to enhance the professionalism, empathy, and cultural awareness of mammogram technologists, reduce barriers, and provide positive expectations and incentives could improve satisfaction and compliance with screening mammography. PMID:24183414

  2. Mammographic enhancement with combining local statistical measures and sliding band filter for improved mass segmentation in mammograms

    NASA Astrophysics Data System (ADS)

    Kim, Dae Hoe; Choi, Jae Young; Choi, Seon Hyeong; Ro, Yong Man

    2012-03-01

    In this study, a novel mammogram enhancement solution is proposed, aiming to improve the quality of subsequent mass segmentation in mammograms. It has been widely accepted that characteristics of masses are usually hyper-dense or uniform density with respect to its background. Also, their core parts are likely to have high-intensity values while the values of intensity tend to be decreased as the distance to core parts increases. Based on the aforementioned observations, we develop a new and effective mammogram enhancement method by combining local statistical measurements and Sliding Band Filtering (SBF). By effectively combining local statistical measurements and SBF, we are able to improve the contrast of the bright and smooth regions (which represent potential mass regions), as well as, at the same time, the regions where their surrounding gradients are converging to the centers of regions of interest. In this study, 89 mammograms were collected from the public MAIS database (DB) to demonstrate the effectiveness of the proposed enhancement solution in terms of improving mass segmentation. As for a segmentation method, widely used contour-based segmentation approach was employed. The contour-based method in conjunction with the proposed enhancement solution achieved overall detection accuracy of 92.4% with a total of 85 correct cases. On the other hand, without using our enhancement solution, overall detection accuracy of the contour-based method was only 78.3%. In addition, experimental results demonstrated the feasibility of our enhancement solution for the purpose of improving detection accuracy on mammograms containing dense parenchymal patterns.

  3. A Community-Based Partnership to Successfully Implement and Maintain a Breast Health Navigation Program.

    PubMed

    Drake, Bettina F; Tannan, Shivon; Anwuri, Victoria V; Jackson, Sherrill; Sanford, Mark; Tappenden, Jennifer; Goodman, Melody S; Colditz, Graham A

    2015-12-01

    Breast cancer screening combined with follow-up and treatment reduces breast cancer mortality. However, in the study clinic, only 12 % of eligible women ≥40 years received a mammogram in the previous year. The objective of this project was to implement patient navigation, in our partner health clinic to (1) identify women overdue for a mammogram; and (2) increase mammography utilization in this population over a 2-year period. Women overdue for a mammogram were identified. One patient navigator made navigation attempts over a 2-year period (2009-2011). Navigation included working around systems- and individual-level barriers to receive a mammogram as well as the appropriate follow-up post screening. Women were contacted up to three times to initiate navigation. The proportion of women navigated and who received a mammogram during the study period were compared to women who did not receive a mammogram using Chi square tests for categorical variables and t tests for continuous variables with an α = 0.05. Barriers to previous mammography were also assessed. With 94.8 % of eligible women navigated and 94 % of these women completing mammography, the implementation project reached 89 % of the target population. This project was a successful implementation of an evidence-based patient navigation program that continues to provide significant impact in a high-need area. Cost was the most commonly cite barrier to mammography. Increasing awareness of resources in the community for mammography and follow-up care remains a necessary adjunct to removing structural and financial barriers to accessing preventive services.

  4. 21 CFR 900.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... radiographic image of a phantom. (ll) Physical science means physics, chemistry, radiation science (including medical physics and health physics), and engineering. (mm) Positive mammogram means a mammogram that has... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MAMMOGRAPHY QUALITY...

  5. Women with Disabilities and Breast Cancer Screening

    MedlinePlus

    ... Likely to Have Received a Mammogram During the Past Two Years 1 Breast Cancer Screening Recommendations 2 If you ... of Age Who Received a Mammogram During the Past 2 Years, By Disability Status – 2010 National Household Interview Survey( ...

  6. Design and implementation of a distributed large-scale spatial database system based on J2EE

    NASA Astrophysics Data System (ADS)

    Gong, Jianya; Chen, Nengcheng; Zhu, Xinyan; Zhang, Xia

    2003-03-01

    With the increasing maturity of distributed object technology, CORBA, .NET and EJB are universally used in traditional IT field. However, theories and practices of distributed spatial database need farther improvement in virtue of contradictions between large scale spatial data and limited network bandwidth or between transitory session and long transaction processing. Differences and trends among of CORBA, .NET and EJB are discussed in details, afterwards the concept, architecture and characteristic of distributed large-scale seamless spatial database system based on J2EE is provided, which contains GIS client application, web server, GIS application server and spatial data server. Moreover the design and implementation of components of GIS client application based on JavaBeans, the GIS engine based on servlet, the GIS Application server based on GIS enterprise JavaBeans(contains session bean and entity bean) are explained.Besides, the experiments of relation of spatial data and response time under different conditions are conducted, which proves that distributed spatial database system based on J2EE can be used to manage, distribute and share large scale spatial data on Internet. Lastly, a distributed large-scale seamless image database based on Internet is presented.

  7. Utility of adaptive control processing for the interpretation of digital mammograms.

    PubMed

    Jinnouchi, Mikako; Yabuuchi, Hidetake; Kubo, Makoto; Tokunaga, Eriko; Yamamoto, Hidetaka; Honda, Hiroshi

    2016-11-01

    Background Adaptive control processing for mammography (ACM) is a novel program that automatically sets up appropriate image-processing parameters for individual mammograms (MMGs) by analyzing the focal and whole breast histogram. Purpose To investigate whether ACM improves the image contrast of digital MMGs and whether it improves radiologists' diagnostic performance in reading of MMGs. Material and Methods One hundred normal cases for image quality assessment and another 100 cases (50 normal and 50 cancers) for observer performance assessment were enrolled. All mammograms were examined with and without ACM. Five radiologists assessed the intra- and extra-mammary contrast of 100 normal MMGs, and the mean scores of the intra- and extra-mammary contrast were compared between MMGs with and without ACM in both the dense and non-dense group. They classified 100 MMGs into BI-RADS categories 1-5, and were asked to rate the images on a scale of 0 to 100 for the likelihood of the presence of category 3-5 lesions in each breast. Detectability of breast cancer, reading time, and frequency of window adjustment were compared between MMGs with and without ACM. Results ACM improved the intra-mammary contrast in both the dense and non-dense group but degraded extra-mammary contrast in the dense group. There was no significant difference in detectability of breast cancer between MMGs with and without ACM. Frequency of window adjustment without ACM was significantly higher than that with ACM. Reading time without ACM was significantly longer than that with ACM. Conclusion ACM improves the image contrast of MMGs and shortens reading time.

  8. The effect of a couples intervention to increase breast cancer screening among korean americans.

    PubMed

    Lee, Eunice; Menon, Usha; Nandy, Karabi; Szalacha, Laura; Kviz, Frederick; Cho, Young; Miller, Arlene; Park, Hanjong

    2014-05-01

    To assess the efficacy of Korean Immigrants and Mammography-Culture-Specific Health Intervention (KIM-CHI), an educational program for Korean American (KA) couples designed to improve mammography uptake among KA women. A two-group cluster randomized, longitudinal, controlled design. 50 KA religious organizations in the Chicago area. 428 married KA women 40 years of age or older who had not had a mammogram in the past year. The women and their husbands were recruited from 50 KA religious organizations. Couples were randomly assigned to intervention or attention control groups. Those in the KIM-CHI program (n = 211 couples) were compared to an attention control group (n = 217 couples) at baseline, as well as at 6 and 15 months postintervention on mammogram uptake. Sociodemographic variables and mammography uptake were measured. Level of acculturation was measured using the Suinn-Lew Asian Self-Identity Acculturation Scale. Researchers asked questions about healthcare resources and use, health insurance status, usual source of care, physical examinations in the past two years, family history of breast cancer, and history of mammography. The KIM-CHI group showed statistically significant increases in mammography uptake compared to the attention control group at 6 months and 15 months postintervention. The culturally targeted KIM-CHI program was effective in increasing mammogram uptake among nonadherent KA women. Nurses and healthcare providers should consider specific health beliefs as well as inclusion of husbands or significant others. They also should target education to be culturally relevant for KA women to effectively improve frequency of breast cancer screening.

  9. Breast cancer screening practices among first-generation immigrant muslim women.

    PubMed

    Hasnain, Memoona; Menon, Usha; Ferrans, Carol Estwing; Szalacha, Laura

    2014-07-01

    The purpose of this study was to identify beliefs about breast cancer, screening practices, and factors associated with mammography use among first-generation immigrant Muslim women in Chicago, IL. A convenience sample of 207 first-generation immigrant Muslim women (Middle Eastern 51%; South Asian 49%) completed a culturally adapted questionnaire developed from established instruments. The questionnaire was administered in Urdu, Hindi, Arabic, or English, based on participant preference. Internal-consistency reliability was demonstrated for all scales (alpha coefficients ranged from 0.64 to 0.91). Associations between enabling, predisposing, and need variables and the primary outcome of mammography use were explored by fitting logistic regression models. Although 70% of the women reported having had a mammogram at least once, only 52% had had one within the past 2 years. Four factors were significant predictors of ever having had a mammogram: years in the United States, self-efficacy, perceived importance of mammography, and intent to be screened. Five factors were significant predictors of adherence (having had a mammogram in the past 2 years): years in the United States, having a primary care provider, perceived importance of mammography, barriers, and intent to be screened. This article sheds light on current screening practices and identifies theory-based constructs that facilitate and hinder Muslim women's participation in mammography screening. Our findings provide insights for reaching out particularly to new immigrants, developing patient education programs grounded in culturally appropriate approaches to address perceived barriers and building women's self-efficacy, as well as systems-level considerations for ensuring access to primary care providers.

  10. A topology visualization early warning distribution algorithm for large-scale network security incidents.

    PubMed

    He, Hui; Fan, Guotao; Ye, Jianwei; Zhang, Weizhe

    2013-01-01

    It is of great significance to research the early warning system for large-scale network security incidents. It can improve the network system's emergency response capabilities, alleviate the cyber attacks' damage, and strengthen the system's counterattack ability. A comprehensive early warning system is presented in this paper, which combines active measurement and anomaly detection. The key visualization algorithm and technology of the system are mainly discussed. The large-scale network system's plane visualization is realized based on the divide and conquer thought. First, the topology of the large-scale network is divided into some small-scale networks by the MLkP/CR algorithm. Second, the sub graph plane visualization algorithm is applied to each small-scale network. Finally, the small-scale networks' topologies are combined into a topology based on the automatic distribution algorithm of force analysis. As the algorithm transforms the large-scale network topology plane visualization problem into a series of small-scale network topology plane visualization and distribution problems, it has higher parallelism and is able to handle the display of ultra-large-scale network topology.

  11. Cognizance and utilization about breast cancer screening among the health professional female students and staffs of University Kuala Lumpur, Royal College of Medicine Perak, Malaysia

    PubMed Central

    Haque, A. T. M. Emdadul; Mohd Hisham, Muhammad Afif Bin; Ahmad Adzman, Noor Azwa Laili Binti; Azudin, Nur Atiqah Binti; Shafri, Nursakinah Binti; Haque, Mainul

    2016-01-01

    Background: Breast cancer (BC) is a major life-threatening problem and a global concern including Malaysia. BC is an equal threat for both developing and developed countries. The aim of this study was to determine the relationship between sociodemographic factors with knowledge, attitude, and perception on BC screening among the females of University Kuala Lumpur, Royal College of Medicine Perak (UniKL RCMP). Materials and Methods: This cross-sectional study was conducted from 2015 to 2016. The populations included were the students and staff of UniKL RCMP. The simple sampling method was used and a set of questionnaire was prepared and distributed to the participants who were willing to participate. The data were analyzed by using the SPSS version 17. Results: Of the 220 only 203 questionnaires were returned. Nearly 87.7% of participants indicated genetic factors as the cause of BC, followed by exposure to carcinogenic and X-ray. Excessive smoking (54.2%) and sedentary lifestyle (52.2%) were the risk factors of the BC. 100% of participants thought that breast self-examination (BSE) is important to detect a breast lump and most of them (76.8%) knew what a mammogram is but only 2.0% went for a mammogram. Chemotherapy (71.9%) and surgery (71.9%) were treatments options according to study participants. Nearly 91.1% agreed that regular mammogram could help to detect BC at an early stage. Nearly 88.2% thought BC is not easily curable. Finally, for the attitude on BC screening, most of them knew how to perform BSE (69.0%) with the frequency of 36.0% doing it once a year. Conclusions: The majority of the participants found the good knowledge on BC and on how to perform BSE. Although most of them knew what a mammogram is, only a few have gone for it since perhaps it is recommended for those who are above 50-year-old. Therefore, researchers believe and trust that there is an urgent need of state-funded multicenter study to prevent and early diagnosis of BC in Malaysia. PMID:28144097

  12. Cognizance and utilization about breast cancer screening among the health professional female students and staffs of University Kuala Lumpur, Royal College of Medicine Perak, Malaysia.

    PubMed

    Haque, A T M Emdadul; Mohd Hisham, Muhammad Afif Bin; Ahmad Adzman, Noor Azwa Laili Binti; Azudin, Nur Atiqah Binti; Shafri, Nursakinah Binti; Haque, Mainul

    2016-01-01

    Breast cancer (BC) is a major life-threatening problem and a global concern including Malaysia. BC is an equal threat for both developing and developed countries. The aim of this study was to determine the relationship between sociodemographic factors with knowledge, attitude, and perception on BC screening among the females of University Kuala Lumpur, Royal College of Medicine Perak (UniKL RCMP). This cross-sectional study was conducted from 2015 to 2016. The populations included were the students and staff of UniKL RCMP. The simple sampling method was used and a set of questionnaire was prepared and distributed to the participants who were willing to participate. The data were analyzed by using the SPSS version 17. Of the 220 only 203 questionnaires were returned. Nearly 87.7% of participants indicated genetic factors as the cause of BC, followed by exposure to carcinogenic and X-ray. Excessive smoking (54.2%) and sedentary lifestyle (52.2%) were the risk factors of the BC. 100% of participants thought that breast self-examination (BSE) is important to detect a breast lump and most of them (76.8%) knew what a mammogram is but only 2.0% went for a mammogram. Chemotherapy (71.9%) and surgery (71.9%) were treatments options according to study participants. Nearly 91.1% agreed that regular mammogram could help to detect BC at an early stage. Nearly 88.2% thought BC is not easily curable. Finally, for the attitude on BC screening, most of them knew how to perform BSE (69.0%) with the frequency of 36.0% doing it once a year. The majority of the participants found the good knowledge on BC and on how to perform BSE. Although most of them knew what a mammogram is, only a few have gone for it since perhaps it is recommended for those who are above 50-year-old. Therefore, researchers believe and trust that there is an urgent need of state-funded multicenter study to prevent and early diagnosis of BC in Malaysia.

  13. 21 CFR 900.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... radiographic image of a phantom. (ll) Physical science means physics, chemistry, radiation science (including medical physics and health physics), and engineering. (mm) Positive mammogram means a mammogram that has... 50 percent adipose tissue. (vv) Survey means an onsite physics consultation and evaluation of a...

  14. 21 CFR 900.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... radiographic image of a phantom. (ll) Physical science means physics, chemistry, radiation science (including medical physics and health physics), and engineering. (mm) Positive mammogram means a mammogram that has... 50 percent adipose tissue. (vv) Survey means an onsite physics consultation and evaluation of a...

  15. 21 CFR 900.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... radiographic image of a phantom. (ll) Physical science means physics, chemistry, radiation science (including medical physics and health physics), and engineering. (mm) Positive mammogram means a mammogram that has... 50 percent adipose tissue. (vv) Survey means an onsite physics consultation and evaluation of a...

  16. Automated System for Early Breast Cancer Detection in Mammograms

    NASA Technical Reports Server (NTRS)

    Bankman, Isaac N.; Kim, Dong W.; Christens-Barry, William A.; Weinberg, Irving N.; Gatewood, Olga B.; Brody, William R.

    1993-01-01

    The increasing demand on mammographic screening for early breast cancer detection, and the subtlety of early breast cancer signs on mammograms, suggest an automated image processing system that can serve as a diagnostic aid in radiology clinics. We present a fully automated algorithm for detecting clusters of microcalcifications that are the most common signs of early, potentially curable breast cancer. By using the contour map of the mammogram, the algorithm circumvents some of the difficulties encountered with standard image processing methods. The clinical implementation of an automated instrument based on this algorithm is also discussed.

  17. Breast cancer screening practices among Asian Americans and Pacific Islanders.

    PubMed

    Oh, Kyeung Mi; Zhou, Qiuping Pearl; Kreps, Gary L; Ryu, Shin Kue

    2012-09-01

    To compare the breast cancer screening practices and related factors between Asian Americans and Pacific Islanders (PIs) and non-Hispanic whites. Using 2008 Behavioral Risk Factor Surveillance System data, reported mammogram usage among women aged 40+ were compared. Covariates included demographics, risk behaviors, health perception, care access, and general health practice behavior. PIs had higher rates of screening mammogram usage than did Asian Americans. Most covariates had different levels of influence on mammogram screening for the 2 groups, with a few in opposite directions. Understanding the magnitude and predictors of these disparities for racial/ethnic groups can help inform targeted interventions.

  18. A new breast cancer risk analysis approach using features extracted from multiple sub-regions on bilateral mammograms

    NASA Astrophysics Data System (ADS)

    Sun, Wenqing; Tseng, Tzu-Liang B.; Zheng, Bin; Zhang, Jianying; Qian, Wei

    2015-03-01

    A novel breast cancer risk analysis approach is proposed for enhancing performance of computerized breast cancer risk analysis using bilateral mammograms. Based on the intensity of breast area, five different sub-regions were acquired from one mammogram, and bilateral features were extracted from every sub-region. Our dataset includes 180 bilateral mammograms from 180 women who underwent routine screening examinations, all interpreted as negative and not recalled by the radiologists during the original screening procedures. A computerized breast cancer risk analysis scheme using four image processing modules, including sub-region segmentation, bilateral feature extraction, feature selection, and classification was designed to detect and compute image feature asymmetry between the left and right breasts imaged on the mammograms. The highest computed area under the curve (AUC) is 0.763 ± 0.021 when applying the multiple sub-region features to our testing dataset. The positive predictive value and the negative predictive value were 0.60 and 0.73, respectively. The study demonstrates that (1) features extracted from multiple sub-regions can improve the performance of our scheme compared to using features from whole breast area only; (2) a classifier using asymmetry bilateral features can effectively predict breast cancer risk; (3) incorporating texture and morphological features with density features can boost the classification accuracy.

  19. Application of texture analysis method for mammogram density classification

    NASA Astrophysics Data System (ADS)

    Nithya, R.; Santhi, B.

    2017-07-01

    Mammographic density is considered a major risk factor for developing breast cancer. This paper proposes an automated approach to classify breast tissue types in digital mammogram. The main objective of the proposed Computer-Aided Diagnosis (CAD) system is to investigate various feature extraction methods and classifiers to improve the diagnostic accuracy in mammogram density classification. Texture analysis methods are used to extract the features from the mammogram. Texture features are extracted by using histogram, Gray Level Co-Occurrence Matrix (GLCM), Gray Level Run Length Matrix (GLRLM), Gray Level Difference Matrix (GLDM), Local Binary Pattern (LBP), Entropy, Discrete Wavelet Transform (DWT), Wavelet Packet Transform (WPT), Gabor transform and trace transform. These extracted features are selected using Analysis of Variance (ANOVA). The features selected by ANOVA are fed into the classifiers to characterize the mammogram into two-class (fatty/dense) and three-class (fatty/glandular/dense) breast density classification. This work has been carried out by using the mini-Mammographic Image Analysis Society (MIAS) database. Five classifiers are employed namely, Artificial Neural Network (ANN), Linear Discriminant Analysis (LDA), Naive Bayes (NB), K-Nearest Neighbor (KNN), and Support Vector Machine (SVM). Experimental results show that ANN provides better performance than LDA, NB, KNN and SVM classifiers. The proposed methodology has achieved 97.5% accuracy for three-class and 99.37% for two-class density classification.

  20. Application of adaptive boosting to EP-derived multilayer feed-forward neural networks (MLFN) to improve benign/malignant breast cancer classification

    NASA Astrophysics Data System (ADS)

    Land, Walker H., Jr.; Masters, Timothy D.; Lo, Joseph Y.; McKee, Dan

    2001-07-01

    A new neural network technology was developed for improving the benign/malignant diagnosis of breast cancer using mammogram findings. A new paradigm, Adaptive Boosting (AB), uses a markedly different theory in solutioning Computational Intelligence (CI) problems. AB, a new machine learning paradigm, focuses on finding weak learning algorithm(s) that initially need to provide slightly better than random performance (i.e., approximately 55%) when processing a mammogram training set. Then, by successive development of additional architectures (using the mammogram training set), the adaptive boosting process improves the performance of the basic Evolutionary Programming derived neural network architectures. The results of these several EP-derived hybrid architectures are then intelligently combined and tested using a similar validation mammogram data set. Optimization focused on improving specificity and positive predictive value at very high sensitivities, where an analysis of the performance of the hybrid would be most meaningful. Using the DUKE mammogram database of 500 biopsy proven samples, on average this hybrid was able to achieve (under statistical 5-fold cross-validation) a specificity of 48.3% and a positive predictive value (PPV) of 51.8% while maintaining 100% sensitivity. At 97% sensitivity, a specificity of 56.6% and a PPV of 55.8% were obtained.

  1. Factors related to noncompliance with screening mammogram appointments among low-income African-American women.

    PubMed Central

    Crump, S. R.; Mayberry, R. M.; Taylor, B. D.; Barefield, K. P.; Thomas, P. E.

    2000-01-01

    Despite current mammography recommendations, screening rates among African-American women are suboptimal. The purpose of this case-control study was to identify the psychological, demographic, and health care system barriers to screening mammography use among low-income African-American women. A total of 574 women with screening mammogram appointments at an urban hospital were interviewed to determine the predictors of mammogram appointment noncompliance. Predictor variables included: demographics; breast cancer knowledge, attitudes, beliefs, and screening practices; and type of health care provider making the referral. Age was inversely related to mammogram appointment noncompliance. Relative to women 40 to 49 years old, women 70 years of age and older were the least likely to miss their appointments (odds ratio [OR], 0.3; 95% confidence interval [CI], 0.2, 0.5). Women referred for mammography by a physician's assistant or nurse practitioner were less likely to miss their appointments than women referred by a physician (OR, 0.3; 95% CI, 0.1, 0.8). Embarrassment, lack of breast symptoms, and forgetfulness also contributed to noncompliance. Key demographic, attitudinal, and health care system factors hinder low-income African-American women from obtaining screening mammograms. These findings have significant health education and policy implications for health care delivery to women in this population. PMID:10881473

  2. Workflow management in large distributed systems

    NASA Astrophysics Data System (ADS)

    Legrand, I.; Newman, H.; Voicu, R.; Dobre, C.; Grigoras, C.

    2011-12-01

    The MonALISA (Monitoring Agents using a Large Integrated Services Architecture) framework provides a distributed service system capable of controlling and optimizing large-scale, data-intensive applications. An essential part of managing large-scale, distributed data-processing facilities is a monitoring system for computing facilities, storage, networks, and the very large number of applications running on these systems in near realtime. All this monitoring information gathered for all the subsystems is essential for developing the required higher-level services—the components that provide decision support and some degree of automated decisions—and for maintaining and optimizing workflow in large-scale distributed systems. These management and global optimization functions are performed by higher-level agent-based services. We present several applications of MonALISA's higher-level services including optimized dynamic routing, control, data-transfer scheduling, distributed job scheduling, dynamic allocation of storage resource to running jobs and automated management of remote services among a large set of grid facilities.

  3. Towards an in-plane methodology to track breast lesions using mammograms and patient-specific finite-element simulations

    NASA Astrophysics Data System (ADS)

    Lapuebla-Ferri, Andrés; Cegoñino-Banzo, José; Jiménez-Mocholí, Antonio-José; Pérez del Palomar, Amaya

    2017-11-01

    In breast cancer screening or diagnosis, it is usual to combine different images in order to locate a lesion as accurately as possible. These images are generated using a single or several imaging techniques. As x-ray-based mammography is widely used, a breast lesion is located in the same plane of the image (mammogram), but tracking it across mammograms corresponding to different views is a challenging task for medical physicians. Accordingly, simulation tools and methodologies that use patient-specific numerical models can facilitate the task of fusing information from different images. Additionally, these tools need to be as straightforward as possible to facilitate their translation to the clinical area. This paper presents a patient-specific, finite-element-based and semi-automated simulation methodology to track breast lesions across mammograms. A realistic three-dimensional computer model of a patient’s breast was generated from magnetic resonance imaging to simulate mammographic compressions in cranio-caudal (CC, head-to-toe) and medio-lateral oblique (MLO, shoulder-to-opposite hip) directions. For each compression being simulated, a virtual mammogram was obtained and posteriorly superimposed to the corresponding real mammogram, by sharing the nipple as a common feature. Two-dimensional rigid-body transformations were applied, and the error distance measured between the centroids of the tumors previously located on each image was 3.84 mm and 2.41 mm for CC and MLO compression, respectively. Considering that the scope of this work is to conceive a methodology translatable to clinical practice, the results indicate that it could be helpful in supporting the tracking of breast lesions.

  4. Mammography performance in Oman: Review of factors influencing cancer yield and positive predictive value.

    PubMed

    Taif, Sawsan; Tufail, Fatma; Alnuaimi, Ahmed Sameer

    2016-06-01

    The aim of this study is to assess mammography performance in Oman by estimating the breast cancer rate and the positive predictive value (PPV) with the influence of some variables. This cross-sectional study was conducted on mammograms done in one of the three main breast imaging centers in Oman between January 2008 and July 2012. Diagnostic and screening groups were identified and assessed separately. Rate of abnormal mammograms, rate of breast cancer and the PPV were estimated according to Breast Imaging Reporting and Data System (BIRADS) score, presence of breast lump and patient's age. Total of 653 mammograms were included, 254 diagnostic and 399 screening. Abnormal mammograms (BIRADS 4 and 5) form 31.9% of the diagnostic examinations compared with 6.8% of screening examinations. Breast cancer was present in 17.9% of the diagnostic compared with 1.0% of the screening group. The PPV of BIRADS 5 was 94.1%, and for BIRADS 4 was 37.1 and 26.7% for diagnostic and screening studies. Overall PPV for abnormal mammograms was 65.2% in the diagnostic and 26.7% in the screening group. Mammography PPV shows positive association with age (P = 0.039) while presence of breast lump has no significant effect on the PPV (P = 0.38). BIRADS 5 score was found to have a high cancer yield making it a strong predictor of cancer. Different results were obtained in the diagnostic compared with screening mammography with higher rates of abnormal mammograms and breast cancer. Mammography performance should be better in the older women. © 2014 Wiley Publishing Asia Pty Ltd.

  5. Double versus single reading of mammograms in a breast cancer screening programme: a cost-consequence analysis.

    PubMed

    Posso, Margarita C; Puig, Teresa; Quintana, Ma Jesus; Solà-Roca, Judit; Bonfill, Xavier

    2016-09-01

    To assess the costs and health-related outcomes of double versus single reading of digital mammograms in a breast cancer screening programme. Based on data from 57,157 digital screening mammograms from women aged 50-69 years, we compared costs, false-positive results, positive predictive value and cancer detection rate using four reading strategies: double reading with and without consensus and arbitration, and single reading with first reader only and second reader only. Four highly trained radiologists read the mammograms. Double reading with consensus and arbitration was 15 % (Euro 334,341) more expensive than single reading with first reader only. False-positive results were more frequent at double reading with consensus and arbitration than at single reading with first reader only (4.5 % and 4.2 %, respectively; p < 0.001). The positive predictive value (9.3 % and 9.1 %; p = 0.812) and cancer detection rate were similar for both reading strategies (4.6 and 4.2 per 1000 screens; p = 0.283). Our results suggest that changing to single reading of mammograms could produce savings in breast cancer screening. Single reading could reduce the frequency of false-positive results without changing the cancer detection rate. These results are not conclusive and cannot be generalized to other contexts with less trained radiologists. • Double reading of digital mammograms is more expensive than single reading. • Compared to single reading, double reading yields a higher proportion of false-positive results. • The cancer detection rate was similar for double and single readings. • Single reading may be a cost-effective strategy in breast cancer screening programmes.

  6. The Effect of California's Breast Density Notification Legislation on Breast Cancer Screening.

    PubMed

    Chau, Stephanie Lynn; Alabaster, Amy; Luikart, Karin; Brenman, Leslie Manace; Habel, Laurel A

    2017-04-01

    Half of US states mandate women be notified if they have dense breasts on their mammogram, yet guidelines and data on supplemental screening modalities are limited. Breast density (BD) refers to the extent that breast tissue appears radiographically dense on mammograms. High BD reduces the sensitivity of screening mammography and increases breast cancer risk. The aim of this study was to determine the potential impact of California's 2013 BD notification legislation on breast cancer screening patterns. We conducted a cohort study of women aged 40 to 74 years who were members of a large Northern California integrated health plan (approximately 3.9 million members) in 2011-2015. We calculated pre- and post-legislation rates of screening mammography and magnetic resonance imaging (MRI). We also examined whether women with dense breasts (defined as BI-RADS density c or d) had higher MRI rates than women with nondense breasts (defined as BI-RADS density a or b). After adjustment for race/ethnicity, age, body mass index, medical facility, neighborhood median income, and cancer history, there was a relative 6.6% decrease (relative risk [RR] 0.934, confidence interval [CI] 0.92-0.95) in the rate of screening mammography, largely driven by a decrease among women <50 years. While infrequent, there was a relative 16% increase (RR 1.16, CI 1.07-1.25) in the rate of screening MRI, with the greatest increase among the youngest women. In the postlegislation period, women with extremely dense breasts (BI-RADS d) had 2.77 times (CI 1.93-3.95) the odds of a MRI within 9 months of a screening mammogram compared with women with nondense breasts (BI-RADS b). In this setting, MRI rates increased in the postlegislation period. In addition, women with higher BD were more likely to have supplementary MRI. The decrease in mammography rates seen primarily among younger women may have been due to changes in national screening guidelines.

  7. Automatic localization of the nipple in mammograms using Gabor filters and the Radon transform

    NASA Astrophysics Data System (ADS)

    Chakraborty, Jayasree; Mukhopadhyay, Sudipta; Rangayyan, Rangaraj M.; Sadhu, Anup; Azevedo-Marques, P. M.

    2013-02-01

    The nipple is an important landmark in mammograms. Detection of the nipple is useful for alignment and registration of mammograms in computer-aided diagnosis of breast cancer. In this paper, a novel approach is proposed for automatic detection of the nipple based on the oriented patterns of the breast tissues present in mammograms. The Radon transform is applied to the oriented patterns obtained by a bank of Gabor filters to detect the linear structures related to the tissue patterns. The detected linear structures are then used to locate the nipple position using the characteristics of convergence of the tissue patterns towards the nipple. The performance of the method was evaluated with 200 scanned-film images from the mini-MIAS database and 150 digital radiography (DR) images from a local database. Average errors of 5:84 mm and 6:36 mm were obtained with respect to the reference nipple location marked by a radiologist for the mini-MIAS and the DR images, respectively.

  8. Mammography status using patient self-reports and computerized radiology database.

    PubMed

    Thompson, B; Taylor, V; Goldberg, H; Mullen, M

    1999-10-01

    This study sought to compare self-reported mammography use of low-income women utilizing an inner-city public hospital with a computerized hospital database for tracking mammography use. A survey of all age-eligible women using the hospital's internal medicine clinic was done; responses were matched with the radiology database. We examined concordance among the two data sources. Concordance between self-report and the database was high (82%) when using "ever had a mammogram at the hospital," but low (58%) when comparing self-reported last mammogram with the information contained in the database. Disagreements existed between self-reports and the database. Because we sought to ensure that women would know exactly what a mammogram entailed by including a picture of a woman having a mammogram, it is possible that women's responses were accurate, leading to concerns that discrepancies might be present in the database. Physicians and staff must ensure that they understand the full history of a woman's experience with mammography before recommending for or against the procedure.

  9. Computer aided system for segmentation and visualization of microcalcifications in digital mammograms.

    PubMed

    Reljin, Branimir; Milosević, Zorica; Stojić, Tomislav; Reljin, Irini

    2009-01-01

    Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal "images" are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph.

  10. Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system.

    PubMed

    Tanaka, Toyohiko; Nitta, Norihisa; Ohta, Shinichi; Kobayashi, Tsuyoshi; Kano, Akiko; Tsuchiya, Keiko; Murakami, Yoko; Kitahara, Sawako; Wakamiya, Makoto; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2009-12-01

    A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-μm-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages.

  11. A crisis of visibility: The psychological consequences of false-positive screening mammograms, an interview study.

    PubMed

    Bond, Mary; Garside, Ruth; Hyde, Christopher

    2015-11-01

    To understand the meaning of having a false-positive screening mammogram. Qualitative interview study. Twenty-one women, who had experienced false-positive screening mammograms, took part in semi-structured interviews that were analysed with Interpretive Phenomenological Analysis. This research took place in the United Kingdom. The analysis revealed a wide range of response to having a false-positive mammogram, from nonchalance to extreme fear. These reactions come from the potential for the belief that one is healthy to be challenged by being recalled, as the worst is frequently assumed. For most, the image of the lesion on the X-ray brought the reality of this challenge into sharp focus, as they might soon discover they had breast cancer. Waiting, whether for the appointment, at the clinic or for biopsy results was considered the worst aspect of being recalled. Generally, the uncertainty was quickly resolved with the pronouncement of the 'all-clear', which brought considerable relief and the restoration of belief in the healthy self. However, for some, lack of information, contradictory information, or poor interpersonal communication meant that uncertainty about their health status lingered at least until their next normal screening mammogram. Mammography screening related anxiety lasted for up to 12 years. Breast cancer screening produces a 'crisis of visibility'. Accepting the screening invitation is taking a risk that you may experience unnecessary stress, uncertainty, fear, anxiety, and physical pain. Not accepting the invitation is taking a risk that malignant disease will remain invisible. Statement of contribution What is already known on this subject? More than 50,000 women a year in England have a false-positive mammogram (FPM). Having an FPM can cause anxiety compared with a normal mammogram. The anxiety can last up to 35 months. What does this study add? Refocuses attention from the average response found in quantitative studies to the wide range of individual response. Gives insight into the nature of the anxiety of having FPMs. Highlights the role of uncertainty in provoking distress from an FPM. © 2015 The British Psychological Society.

  12. Inequalities in socioeconomic status and race and the odds of undergoing a mammogram in Brazil.

    PubMed

    Melo, Enirtes Caetano Prates; de Oliveira, Evangelina Xavier Gouveia; Chor, Dóra; Carvalho, Marilia Sá; Pinheiro, Rejane Sobrino

    2016-09-15

    Access to mammograms, in common with other diagnostic procedures, is strongly conditioned by socioeconomic disparities. Which aspects of inequality affect the odds of undergoing a mammogram, and whether they are the same in different localities, are relevant issues related to the success of health policies. This study analyzed data from the 2008 PNAD - Brazilian National Household Sample Survey (11.607 million women 40 years of age or older), on having had at least one mammogram over life for women 40 years of age or older in each of Brazil's nine Metropolitan Regions (MR), according to socioeconomic position. The effects of income, schooling, health insurance and race in the different regions were investigated using multivariate logistical regression for each region individually, and for all MRs combined. The age-adjusted odds of a woman having had a mammogram according to race and stratified by two income strata (and two schooling strata) were also analyzed. Having a higher income increases four to seven times a woman's odds of having had at least one mammogram in all MRs except Curitiba. For schooling, the gradient, though less steep, is favorable to women with more years of study. Having health insurance increases two to three times the odds in all MRs. Multivariate analysis did not show differences due to race (except for the Fortaleza MR), but the stratified analysis by income and schooling shows effects of race in most MRs, with greater differences for women with higher socioeconomic status. This study confirms that income and schooling, as well as having health insurance, are still important determinants of inequality in health service use in Brazil. Additionally, race also contributes to the odds of having had a mammogram. The point is not to isolate the effect of each factor, but to evaluate how their interrelations may exacerbate differences, generating patterns of cumulative adversity, a theme that is still little explored in Brazil. This is much more important when we consider that race has only recently started be included in analyses of health outcomes in Brazil.

  13. Computerized decision support system for mass identification in breast using digital mammogram: a study on GA-based neuro-fuzzy approaches.

    PubMed

    Das, Arpita; Bhattacharya, Mahua

    2011-01-01

    In the present work, authors have developed a treatment planning system implementing genetic based neuro-fuzzy approaches for accurate analysis of shape and margin of tumor masses appearing in breast using digital mammogram. It is obvious that a complicated structure invites the problem of over learning and misclassification. In proposed methodology, genetic algorithm (GA) has been used for searching of effective input feature vectors combined with adaptive neuro-fuzzy model for final classification of different boundaries of tumor masses. The study involves 200 digitized mammograms from MIAS and other databases and has shown 86% correct classification rate.

  14. Comparison of prestellar core elongations and large-scale molecular cloud structures in the Lupus I region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poidevin, Frédérick; Ade, Peter A. R.; Hargrave, Peter C.

    2014-08-10

    Turbulence and magnetic fields are expected to be important for regulating molecular cloud formation and evolution. However, their effects on sub-parsec to 100 parsec scales, leading to the formation of starless cores, are not well understood. We investigate the prestellar core structure morphologies obtained from analysis of the Herschel-SPIRE 350 μm maps of the Lupus I cloud. This distribution is first compared on a statistical basis to the large-scale shape of the main filament. We find the distribution of the elongation position angle of the cores to be consistent with a random distribution, which means no specific orientation of themore » morphology of the cores is observed with respect to the mean orientation of the large-scale filament in Lupus I, nor relative to a large-scale bent filament model. This distribution is also compared to the mean orientation of the large-scale magnetic fields probed at 350 μm with the Balloon-borne Large Aperture Telescope for Polarimetry during its 2010 campaign. Here again we do not find any correlation between the core morphology distribution and the average orientation of the magnetic fields on parsec scales. Our main conclusion is that the local filament dynamics—including secondary filaments that often run orthogonally to the primary filament—and possibly small-scale variations in the local magnetic field direction, could be the dominant factors for explaining the final orientation of each core.« less

  15. Natural History of Breast Density and Breast Cancer Risk

    DTIC Science & Technology

    2001-07-01

    mammography database. We have estimated breast density on the oldest mammogram from both cases and controls, using our semi-automated software and...using the oldest mammogram) with breast cancer risk. Next winter, we will continue these analyses investigating the change in density over time and

  16. Large-scale anisotropy of the cosmic microwave background radiation

    NASA Technical Reports Server (NTRS)

    Silk, J.; Wilson, M. L.

    1981-01-01

    Inhomogeneities in the large-scale distribution of matter inevitably lead to the generation of large-scale anisotropy in the cosmic background radiation. The dipole, quadrupole, and higher order fluctuations expected in an Einstein-de Sitter cosmological model have been computed. The dipole and quadrupole anisotropies are comparable to the measured values, and impose important constraints on the allowable spectrum of large-scale matter density fluctuations. A significant dipole anisotropy is generated by the matter distribution on scales greater than approximately 100 Mpc. The large-scale anisotropy is insensitive to the ionization history of the universe since decoupling, and cannot easily be reconciled with a galaxy formation theory that is based on primordial adiabatic density fluctuations.

  17. Utilization of screening mammography in New Hampshire: a population-based assessment.

    PubMed

    Carney, Patricia A; Goodrich, Martha E; Mackenzie, Todd; Weiss, Julia E; Poplack, Steven P; Wells, Wendy S; Titus-Ernstoff, Linda

    2005-10-15

    The objective of screening mammography is to identify breast carcinoma early, which requires routine screening. Although self-report data indicate that screening utilization is high, the results of this population-based assessment indicated that utilization is lower than reported previously. The authors compared New Hampshire population data from the 2000 Census with clinical encounter data for the corresponding time obtained from the New Hampshire Mammography Network, a mammography registry that captures approximately 90% of the mammograms performed in participating New Hampshire facilities. The results showed that approximately 36% of New Hampshire women either never had a mammogram or had not had a mammogram in > 27 months (irregular screenees), and older women (80 yrs and older) were less likely to be screened (79% unscreened/underscreened) compared with younger women (ages 40-69 yrs; 28-32% unscreened/underscreened). Of the screened women, 44% were adhering to an interval of 14 months, and 21% were adhering within 15 months and 26 months. The remaining 35% of the women had 1 or 2 mammograms and did not return within 27 months. Routine mammography screening may be occurring less often than believed when survey data alone are used. An important, compelling concern is the reason women had one or two mammograms only and then did not return for additional screening. This area deserves additional research. Copyright 2005 American Cancer Society

  18. The Large -scale Distribution of Galaxies

    NASA Astrophysics Data System (ADS)

    Flin, Piotr

    A review of the Large-scale structure of the Universe is given. A connection is made with the titanic work by Johannes Kepler in many areas of astronomy and cosmology. A special concern is made to spatial distribution of Galaxies, voids and walls (cellular structure of the Universe). Finaly, the author is concluding that the large scale structure of the Universe can be observed in much greater scale that it was thought twenty years ago.

  19. Assessing the patient's mammogram experience.

    PubMed

    Dodendorf, Diane M; Deogun, Gurvinder K; Rodie, Amy Risch; Pol, Louis G

    2004-01-01

    This study overviews an operational blueprint that diagrams the activities and interactions of all participants in a typical screening mammography appointment in a large medical center. The blueprint is constructed from multiple sources of data collected from mammography patients, service providers in the radiology department, and medical records. The benefits from using patient perspectives, the insights gained from the blueprint development process, and the value of the resulting screening mammography appointment blueprint are included.

  20. Seamless lesion insertion in digital mammography: methodology and reader study

    NASA Astrophysics Data System (ADS)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  1. Male group size, female distribution and changes in sexual segregation by Roosevelt elk

    PubMed Central

    Peterson, Leah M.

    2017-01-01

    Sexual segregation, or the differential use of space by males and females, is hypothesized to be a function of body size dimorphism. Sexual segregation can also manifest at small (social segregation) and large (habitat segregation) spatial scales for a variety of reasons. Furthermore, the connection between small- and large-scale sexual segregation has rarely been addressed. We studied a population of Roosevelt elk (Cervus elaphus roosevelti) across 21 years in north coastal California, USA, to assess small- and large-scale sexual segregation in winter. We hypothesized that male group size would associate with small-scale segregation and that a change in female distribution would associate with large-scale segregation. Variation in forage biomass might also be coupled to small and large-scale sexual segregation. Our findings were consistent with male group size associating with small-scale segregation and a change in female distribution associating with large-scale segregation. Females appeared to avoid large groups comprised of socially dominant males. Males appeared to occupy a habitat vacated by females because of a wider forage niche, greater tolerance to lethal risks, and, perhaps, to reduce encounters with other elk. Sexual segregation at both spatial scales was a poor predictor of forage biomass. Size dimorphism was coupled to change in sexual segregation at small and large spatial scales. Small scale segregation can seemingly manifest when all forage habitat is occupied by females and large scale segregation might happen when some forage habitat is not occupied by females. PMID:29121076

  2. Architectural Optimization of Digital Libraries

    NASA Technical Reports Server (NTRS)

    Biser, Aileen O.

    1998-01-01

    This work investigates performance and scaling issues relevant to large scale distributed digital libraries. Presently, performance and scaling studies focus on specific implementations of production or prototype digital libraries. Although useful information is gained to aid these designers and other researchers with insights to performance and scaling issues, the broader issues relevant to very large scale distributed libraries are not addressed. Specifically, no current studies look at the extreme or worst case possibilities in digital library implementations. A survey of digital library research issues is presented. Scaling and performance issues are mentioned frequently in the digital library literature but are generally not the focus of much of the current research. In this thesis a model for a Generic Distributed Digital Library (GDDL) and nine cases of typical user activities are defined. This model is used to facilitate some basic analysis of scaling issues. Specifically, the calculation of Internet traffic generated for different configurations of the study parameters and an estimate of the future bandwidth needed for a large scale distributed digital library implementation. This analysis demonstrates the potential impact a future distributed digital library implementation would have on the Internet traffic load and raises questions concerning the architecture decisions being made for future distributed digital library designs.

  3. Travel burden to breast MRI and utilization: are risk and sociodemographics related

    PubMed Central

    Onega, Tracy; Lee, Christoph I.; Benkeser, David; Alford-Teaster, Jennifer; Haas, Jennifer S.; Tosteson, Anna N. A.; Hill, Deirdre; Shi, Xun; Henderson, Louise M.; Hubbard, Rebecca A.

    2016-01-01

    Background Mammograms, unlike magnetic resonance imaging (MRI), are relatively geographically accessible. Additional travel time is often required to access breast MRI. However, the amount of additional travel time and whether it varies based on sociodemographic or breast cancer risk factors is unknown. Methods We examine screening mammograms and MRIs between 2005 and 2012 in the Breast Cancer Surveillance Consortium (BCSC) by a) travel time to the closest and actual mammography facility used, and the difference between the two; b) woman's breast cancer risk factors and c) socio-demographic characteristics. We used logistic regression to examine the odds of traveling farther than the closest facility in relation to women's characteristics. Results Among 821,683 screening mammograms, 76.6% occurred at the closest facility compared to 51.9% of screening MRIs (N=3,687). The median differential travel time among women not using the closest facility for mammography was 14 minutes (IQR: 8-25) versus 20 minutes (IQR 11-40) for breast MRI. Differential travel time for both imaging modalities did not vary notably by breast cancer risk factors, but was significantly longer for non-urban residents. For non-Hispanic black, compared to non-Hispanic white women, the adjusted odds of traveling farther than the closest facility were 9% lower for mammography (OR 0.91; 95% CI:0.87-0.95), but more than two times higher for MRI (OR 2.64; 95% CI:1.36-5.13). Conclusions Breast cancer risk factors were not related to excess travel time for screening MRI, but sociodemographic factors were, suggesting the possibility that geographic distribution of advanced imaging may exacerbated disparities for some vulnerable populations. PMID:27026577

  4. Racial and Ethnic Disparity in Symptomatic Breast Cancer Awareness despite a Recent Screen: The Role of Tumor Biology and Mammography Facility Characteristics.

    PubMed

    Mortel, Mylove; Rauscher, Garth H; Murphy, Anne Marie; Hoskins, Kent; Warnecke, Richard B

    2015-10-01

    In a racially and ethnically diverse sample of recently diagnosed urban patients with breast cancer, we examined associations of patient, tumor biology, and mammography facility characteristics on the probability of symptomatic discovery of their breast cancer despite a recent prior screening mammogram. In the Breast Cancer Care in Chicago study, self-reports at interview were used to define patients as having a screen-detected breast cancer or having symptomatic awareness despite a recent screening mammogram (SADRS), in the past 1 or 2 years. Patients with symptomatic breast cancer who did not report a recent prior screen were excluded from these analyses. Characteristics associated with more aggressive disease [estrogen receptor (ER)- and progesterone receptor (PR)-negative status and higher tumor grade] were abstracted from medical records. Mammogram facility characteristics that might indicate aspects of screening quality were defined and controlled for in some analyses. SADRS was more common among non-Hispanic black and Hispanic than among non-Hispanic white patients (36% and 42% vs. 25%, respectively, P = 0.0004). SADRS was associated with ER/PR-negative and higher-grade disease. Patients screened at sites that relied on dedicated radiologists and sites that were breast imaging centers of excellence were less likely to report SADRS. Tumor and facility factors together accounted for two thirds of the disparity in SADRS (proportion mediated = 70%, P = 0.02). Facility resources and tumor aggressiveness explain much of the racial/ethnic disparity in symptomatic breast cancer among recently screened patients. A more equitable distribution of high-quality screening would ameliorate but not eliminate this disparity. ©2015 American Association for Cancer Research.

  5. Conflicting national recommendations and the use of screening mammography: does the physician's recommendation matter?

    PubMed

    Taplin, S H; Urban, N; Taylor, V M; Savarino, J

    1997-01-01

    This study evaluated whether women's perceptions of the conflicting recommendations for breast cancer screening were associated with decreased use of mammography. We conducted a random-digit-dial telephone survey of 1024 women in four communities of western Washington State. In addition to collecting data for demographics, beliefs about mammography, and insurance coverage, we inquired whether the respondents were aware of any conflicting recommendations about when to begin or how frequently to perform screening mammography, whether their physicians had recommended a mammogram, and whether they were likely to do what their physicians recommended. After grouping women according to whether they perceived conflicting recommendations, we used chi-square statistics to compare the distribution of proportions of women by age, race, household income, education, and insurance coverage. To estimate the odds of their having a mammogram in the previous 2 years (yes or no), we used multivariate logistic regression and included the above variables as covariates. Sixty-two percent of eligible women completed the survey, and 49 percent (479 of 985) perceived conflicting recommendations. The association between perceiving conflict and mammography use was not significant. Eighty-three percent of women who perceived conflicting recommendations reported being more comfortable using their own judgment about getting the procedure. After controlling for whether women perceived conflicting recommendations and all other factors, women who said they followed their physician's advice but did not recall their physician recommending mammography were 71 percent less likely to have received a recent mammogram than were women who reported their physician did recommend it (odds ratio 0.29, confidence interval 0.16-0.51). The conflicting recommendations surrounding breast cancer screening are not influencing women's choices about mammography. The physician recommendation and women's self-reported likeliness to follow it are the most important factors associated with mammography use.

  6. Application of the Minkowski-functionals for automated pattern classification of breast parenchyma depicted by digital mammography

    NASA Astrophysics Data System (ADS)

    Boehm, Holger F.; Fischer, Tanja; Riosk, Dororthea; Britsch, Stefanie; Reiser, Maximilian

    2008-03-01

    With an estimated life-time-risk of about 10%, breast cancer is the most common cancer among women in western societies. Extensive mammography-screening programs have been implemented for diagnosis of the disease at an early stage. Several algorithms for computer-aided detection (CAD) have been proposed to help radiologists manage the increasing number of mammographic image-data and identify new cases of cancer. However, a major issue with most CAD-solutions is the fact that performance strongly depends on the structure and density of the breast tissue. Prior information about the global tissue quality in a patient would be helpful for selecting the most effective CAD-approach in order to increase the sensitivity of lesion-detection. In our study, we propose an automated method for textural evaluation of digital mammograms using the Minkowski Functionals in 2D. 80 mammograms are consensus-classified by two experienced readers as fibrosis, involution/atrophy, or normal. For each case, the topology of graylevel distribution is evaluated within a retromamillary image-section of 512 x 512 pixels. In addition, we obtain parameters from the graylevel-histogram (20th percentile, median and mean graylevel intensity). As a result, correct classification of the mammograms based on the densitometic parameters is achieved in between 38 and 48%, whereas topological analysis increases the rate to 83%. The findings demonstrate the effectiveness of the proposed algorithm. Compared to features obtained from graylevel histograms and comparable studies, we draw the conclusion that the presented method performs equally good or better. Our future work will be focused on the characterization of the mammographic tissue according to the Breast Imaging Reporting and Data System (BI-RADS). Moreover, other databases will be tested for an in-depth evaluation of the efficiency of our proposal.

  7. Correlating mammographic and pathologic findings in clinical decision support using natural language processing and data mining methods.

    PubMed

    Patel, Tejal A; Puppala, Mamta; Ogunti, Richard O; Ensor, Joe E; He, Tiancheng; Shewale, Jitesh B; Ankerst, Donna P; Kaklamani, Virginia G; Rodriguez, Angel A; Wong, Stephen T C; Chang, Jenny C

    2017-01-01

    A key challenge to mining electronic health records for mammography research is the preponderance of unstructured narrative text, which strikingly limits usable output. The imaging characteristics of breast cancer subtypes have been described previously, but without standardization of parameters for data mining. The authors searched the enterprise-wide data warehouse at the Houston Methodist Hospital, the Methodist Environment for Translational Enhancement and Outcomes Research (METEOR), for patients with Breast Imaging Reporting and Data System (BI-RADS) category 5 mammogram readings performed between January 2006 and May 2015 and an available pathology report. The authors developed natural language processing (NLP) software algorithms to automatically extract mammographic and pathologic findings from free text mammogram and pathology reports. The correlation between mammographic imaging features and breast cancer subtype was analyzed using one-way analysis of variance and the Fisher exact test. The NLP algorithm was able to obtain key characteristics for 543 patients who met the inclusion criteria. Patients with estrogen receptor-positive tumors were more likely to have spiculated margins (P = .0008), and those with tumors that overexpressed human epidermal growth factor receptor 2 (HER2) were more likely to have heterogeneous and pleomorphic calcifications (P = .0078 and P = .0002, respectively). Mammographic imaging characteristics, obtained from an automated text search and the extraction of mammogram reports using NLP techniques, correlated with pathologic breast cancer subtype. The results of the current study validate previously reported trends assessed by manual data collection. Furthermore, NLP provides an automated means with which to scale up data extraction and analysis for clinical decision support. Cancer 2017;114-121. © 2016 American Cancer Society. © 2016 American Cancer Society.

  8. Predicting radiologists' true and false positive decisions in reading mammograms by using gaze parameters and image-based features

    NASA Astrophysics Data System (ADS)

    Gandomkar, Ziba; Tay, Kevin; Ryder, Will; Brennan, Patrick C.; Mello-Thoms, Claudia

    2016-03-01

    Radiologists' gaze-related parameters combined with image-based features were utilized to classify suspicious mammographic areas ultimately scored as True Positives (TP) and False Positives (FP). Eight breast radiologists read 120 two-view digital mammograms of which 59 had biopsy proven cancer. Eye tracking data was collected and nearby fixations were clustered together. Suspicious areas on mammograms were independently identified based on thresholding an intensity saliency map followed by automatic segmentation and pruning steps. For each radiologist reported area, radiologist's fixation clusters in the area, as well as neighboring suspicious areas within 2.5° of the center of fixation, were found. A 45-dimensional feature vector containing gaze parameters of the corresponding cluster along with image-based characteristics was constructed. Gaze parameters included total number of fixations in the cluster, dwell time, time to hit the cluster for the first time, maximum number of consecutive fixations, and saccade magnitude of the first fixation in the cluster. Image-based features consisted of intensity, shape, and texture descriptors extracted from the region around the suspicious area, its surrounding tissue, and the entire breast. For each radiologist, a userspecific Support Vector Machine (SVM) model was built to classify the reported areas as TPs or FPs. Leave-one-out cross validation was utilized to avoid over-fitting. A feature selection step was embedded in the SVM training procedure by allowing radial basis function kernels to have 45 scaling factors. The proposed method was compared with the radiologists' performance using the jackknife alternative free-response receiver operating characteristic (JAFROC). The JAFROC figure of merit increased significantly for six radiologists.

  9. Mass detection in digital breast tomosynthesis: Deep convolutional neural network with transfer learning from mammography.

    PubMed

    Samala, Ravi K; Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A; Wei, Jun; Cha, Kenny

    2016-12-01

    Develop a computer-aided detection (CAD) system for masses in digital breast tomosynthesis (DBT) volume using a deep convolutional neural network (DCNN) with transfer learning from mammograms. A data set containing 2282 digitized film and digital mammograms and 324 DBT volumes were collected with IRB approval. The mass of interest on the images was marked by an experienced breast radiologist as reference standard. The data set was partitioned into a training set (2282 mammograms with 2461 masses and 230 DBT views with 228 masses) and an independent test set (94 DBT views with 89 masses). For DCNN training, the region of interest (ROI) containing the mass (true positive) was extracted from each image. False positive (FP) ROIs were identified at prescreening by their previously developed CAD systems. After data augmentation, a total of 45 072 mammographic ROIs and 37 450 DBT ROIs were obtained. Data normalization and reduction of non-uniformity in the ROIs across heterogeneous data was achieved using a background correction method applied to each ROI. A DCNN with four convolutional layers and three fully connected (FC) layers was first trained on the mammography data. Jittering and dropout techniques were used to reduce overfitting. After training with the mammographic ROIs, all weights in the first three convolutional layers were frozen, and only the last convolution layer and the FC layers were randomly initialized again and trained using the DBT training ROIs. The authors compared the performances of two CAD systems for mass detection in DBT: one used the DCNN-based approach and the other used their previously developed feature-based approach for FP reduction. The prescreening stage was identical in both systems, passing the same set of mass candidates to the FP reduction stage. For the feature-based CAD system, 3D clustering and active contour method was used for segmentation; morphological, gray level, and texture features were extracted and merged with a linear discriminant classifier to score the detected masses. For the DCNN-based CAD system, ROIs from five consecutive slices centered at each candidate were passed through the trained DCNN and a mass likelihood score was generated. The performances of the CAD systems were evaluated using free-response ROC curves and the performance difference was analyzed using a non-parametric method. Before transfer learning, the DCNN trained only on mammograms with an AUC of 0.99 classified DBT masses with an AUC of 0.81 in the DBT training set. After transfer learning with DBT, the AUC improved to 0.90. For breast-based CAD detection in the test set, the sensitivity for the feature-based and the DCNN-based CAD systems was 83% and 91%, respectively, at 1 FP/DBT volume. The difference between the performances for the two systems was statistically significant (p-value < 0.05). The image patterns learned from the mammograms were transferred to the mass detection on DBT slices through the DCNN. This study demonstrated that large data sets collected from mammography are useful for developing new CAD systems for DBT, alleviating the problem and effort of collecting entirely new large data sets for the new modality.

  10. Design of Availability-Dependent Distributed Services in Large-Scale Uncooperative Settings

    ERIC Educational Resources Information Center

    Morales, Ramses Victor

    2009-01-01

    Thesis Statement: "Availability-dependent global predicates can be efficiently and scalably realized for a class of distributed services, in spite of specific selfish and colluding behaviors, using local and decentralized protocols". Several types of large-scale distributed systems spanning the Internet have to deal with availability variations…

  11. Wavelet Compression of Satellite-Transmitted Digital Mammograms

    NASA Technical Reports Server (NTRS)

    Zheng, Yuan F.

    2001-01-01

    Breast cancer is one of the major causes of cancer death in women in the United States. The most effective way to treat breast cancer is to detect it at an early stage by screening patients periodically. Conventional film-screening mammography uses X-ray films which are effective in detecting early abnormalities of the breast. Direct digital mammography has the potential to improve the image quality and to take advantages of convenient storage, efficient transmission, and powerful computer-aided diagnosis, etc. One effective alternative to direct digital imaging is secondary digitization of X-ray films. This technique may not provide as high an image quality as the direct digital approach, but definitely have other advantages inherent to digital images. One of them is the usage of satellite-transmission technique for transferring digital mammograms between a remote image-acquisition site and a central image-reading site. This technique can benefit a large population of women who reside in remote areas where major screening and diagnosing facilities are not available. The NASA-Lewis Research Center (LeRC), in collaboration with the Cleveland Clinic Foundation (CCF), has begun a pilot study to investigate the application of the Advanced Communications Technology Satellite (ACTS) network to telemammography. The bandwidth of the T1 transmission is limited (1.544 Mbps) while the size of a mammographic image is huge. It takes a long time to transmit a single mammogram. For example, a mammogram of 4k by 4k pixels with 16 bits per pixel needs more than 4 minutes to transmit. Four images for a typical screening exam would take more than 16 minutes. This is too long a time period for a convenient screening. Consequently, compression is necessary for making satellite-transmission of mammographic images practically possible. The Wavelet Research Group of the Department of Electrical Engineering at The Ohio State University (OSU) participated in the LeRC-CCF collaboration by providing advanced compression technology using wavelet transform. OSU developed a time-efficient software package with various wavelets to compress a serious of mammographic images. This documents reports the result of the compression activities.

  12. Using population-based data to examine preventive services by disability type among dually eligible (Medicare/Medicaid) adults.

    PubMed

    Reichard, Amanda; Fox, Michael H

    2013-04-01

    Individuals dually eligible for Medicaid and Medicare constitute a small percentage of these program's populations but account for a disproportionately large percent of their total costs. While much work has examined high expenditures, little is known about their health and details of their health care utilization. Utilize an important public health surveillance tool to better understand preventive service use among the dual eligible population. This study involved descriptive and regression analyses of dual eligibles in the Medical Expenditure Panel Survey data from pooled alternate years 2000-2008. We classified the sample into 4 mutually exclusive groups: cognitive limitations, physical disabilities, double diagnosis (cognitive limitations and physical disability), or neither cognitive limitations nor physical disability. For most groups, age was significantly associated with preventive services, though direction varies. Older age was linked to greater receipt of flu shots while younger age was associated with greater receipt of Pap tests, mammograms and dental services. Black women in all groups (except cognitive limitations) had an increased likelihood of receiving a Pap test and a mammogram. A subset of dual eligibles drives the majority of expenditures. People with physical disabilities, regardless of whether they also have a cognitive limitation, are among the highest costing and sickest of our non-institutionalized dual eligible population. Efforts to understand and address the challenges faced by women with physical disabilities in accessing Pap tests or mammograms may be helpful in improving the overall health status for this disability group, but also for all dual eligibles. Published by Elsevier Inc.

  13. Medical Advocacy and Supportive Environments for African-Americans Following Abnormal Mammograms.

    PubMed

    Molina, Yamile; Hempstead, Bridgette H; Thompson-Dodd, Jacci; Weatherby, Shauna Rae; Dunbar, Claire; Hohl, Sarah D; Malen, Rachel C; Ceballos, Rachel M

    2015-09-01

    African-American women experience disproportionately adverse outcomes relative to non-Latina White women after an abnormal mammogram result. Research has suggested medical advocacy and staff support may improve outcomes among this population. The purpose of the study was to understand reasons African-American women believe medical advocacy to be important and examine if and how staff can encourage and be supportive of medical advocacy. A convenience-based sample of 30-74-year-old women who self-identified as African-American/Black/of African descent and who had received an abnormal mammogram result was recruited from community-based organizations, mobile mammography services, and the local department of health. This qualitative study included semi-structured interviews. Patients perceived medical advocacy to be particularly important for African-Americans, given mistrust and discrimination present in medical settings and their own familiarity with their bodies and symptoms. Respondents emphasized that staff can encourage medical advocacy through offering information in general in a clear, informative, and empathic style. Cultural competency interventions that train staff how to foster medical advocacy may be a strategy to improve racial disparities following an abnormal mammogram.

  14. Redshift surveys

    NASA Technical Reports Server (NTRS)

    Geller, Margaret J.; Huchra, J. P.

    1991-01-01

    Present-day understanding of the large-scale galaxy distribution is reviewed. The statistics of the CfA redshift survey are briefly discussed. The need for deeper surveys to clarify the issues raised by recent studies of large-scale galactic distribution is addressed.

  15. Intentions to Maintain Adherence to Mammography

    PubMed Central

    Bowling, J. Michael; Brewer, Noel T.; Lipkus, Isaac M.; Skinner, Celette Sugg; Strigo, Tara S.; Rimer, Barbara K.

    2008-01-01

    Abstract Objective Recent attention has focused on moving women from having initial mammograms to maintaining adherence to regular mammography schedules. We examined behavioral intentions to maintain mammography adherence, which include the likelihood of performing a behavior, and implementation intentions, specific action plans to obtain mammograms. Potential predictors were Theory of Planned Behavior constructs, previous barriers, previous mammography maintenance, and age. Methods Respondents were 2062 currently adherent women due for their next mammograms in 3–4 months according to American Cancer Society recommendations for annual screening. Statistical models were used to examine predictors of behavioral and two implementation intentions, including having thought about where women would get their next mammograms and having thought about making appointments. Results With the exception of pros, cons, and subjective norms, all variables predicted behavioral intentions (p ≤ 0.05). Stronger perceived control, previous mammography maintenance, and one barrier (vs. none) predicted being more likely to have thought about where to get their next mammograms. Previous maintenance and no barriers (vs. two) predicted being more likely to have thought about making appointments. Conclusions Our findings suggest that among women currently adherent to mammography, volitional factors, such as barriers, may be better predictors of implementation intentions than motivational factors, such as attitudes. Implementation variables may be useful in understanding how women move from intentions to action. Future research should examine how such factors relate to mammography maintenance behaviors and can be integrated into behavior change interventions. PMID:18657041

  16. Simultaneous detection and classification of breast masses in digital mammograms via a deep learning YOLO-based CAD system.

    PubMed

    Al-Masni, Mohammed A; Al-Antari, Mugahed A; Park, Jeong-Min; Gi, Geon; Kim, Tae-Yeon; Rivera, Patricio; Valarezo, Edwin; Choi, Mun-Taek; Han, Seung-Moo; Kim, Tae-Seong

    2018-04-01

    Automatic detection and classification of the masses in mammograms are still a big challenge and play a crucial role to assist radiologists for accurate diagnosis. In this paper, we propose a novel Computer-Aided Diagnosis (CAD) system based on one of the regional deep learning techniques, a ROI-based Convolutional Neural Network (CNN) which is called You Only Look Once (YOLO). Although most previous studies only deal with classification of masses, our proposed YOLO-based CAD system can handle detection and classification simultaneously in one framework. The proposed CAD system contains four main stages: preprocessing of mammograms, feature extraction utilizing deep convolutional networks, mass detection with confidence, and finally mass classification using Fully Connected Neural Networks (FC-NNs). In this study, we utilized original 600 mammograms from Digital Database for Screening Mammography (DDSM) and their augmented mammograms of 2,400 with the information of the masses and their types in training and testing our CAD. The trained YOLO-based CAD system detects the masses and then classifies their types into benign or malignant. Our results with five-fold cross validation tests show that the proposed CAD system detects the mass location with an overall accuracy of 99.7%. The system also distinguishes between benign and malignant lesions with an overall accuracy of 97%. Our proposed system even works on some challenging breast cancer cases where the masses exist over the pectoral muscles or dense regions. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Large Scale Density Estimation of Blue and Fin Whales (LSD)

    DTIC Science & Technology

    2014-09-30

    172. McDonald, MA, Hildebrand, JA, and Mesnick, S (2009). Worldwide decline in tonal frequencies of blue whale songs . Endangered Species Research 9...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Large Scale Density Estimation of Blue and Fin Whales ...estimating blue and fin whale density that is effective over large spatial scales and is designed to cope with spatial variation in animal density utilizing

  18. Framing Innovation: The Role of Distributed Leadership in Gaining Acceptance of Large-Scale Technology Initiatives

    ERIC Educational Resources Information Center

    Turner, Henry J.

    2014-01-01

    This dissertation of practice utilized a multiple case-study approach to examine distributed leadership within five school districts that were attempting to gain acceptance of a large-scale 1:1 technology initiative. Using frame theory and distributed leadership theory as theoretical frameworks, this study interviewed each district's…

  19. Women's views on reminder letters for screening mammography: Mixed methods study of women from 23 family health networks.

    PubMed

    Kaczorowski, Janusz; Karwalajtys, Tina; Lohfeld, Lynne; Laryea, Stephanie; Anderson, Kelly; Roder, Stefanie; Sebaldt, Rolf J

    2009-06-01

    To explore women's perspectives on the acceptability and content of reminder letters for screening mammography from their family physicians, as well as such letters' effect on screening intentions. Cross-sectional mailed survey followed by focus groups with a subgroup of respondents. Ontario. One family physician was randomly selected from each of 23 family health networks and primary care networks participating in a demonstration project to increase the delivery of preventive services. From the practice roster of each physician, up to 35 randomly selected women aged 50 to 69 years who were due or overdue for screening mammograms and who had received reminder letters from their family physicians within the past 6 months were surveyed. Recall of having received reminder letters and of their content, influence of the letters on decisions to have mammograms, and interest in receiving future reminder letters. Focus group interviews with survey respondents explored the survey findings in greater depth using a standardized interview guide. The response rate to the survey was 55.7% (384 of 689), and 45.1% (173 of 384) of responding women reported having mammograms in the past 6 months. Among women who recalled receiving letters and either making appointments for or having mammograms, 74.8% (122 of 163) indicated that the letters substantially influenced their decisions. Most respondents (77.1% [296 of 384]) indicated that they would like to continue to receive reminders, and 28.9% (111 of 384) indicated that they would like to receive additional information about mammograms. Participants in 2 focus groups (n = 3 and n = 5) indicated that they thought letters reflected a positive attitude of physicians toward mammography screening. They also commented that newly eligible women had different information needs than women who had had mammograms done in the past. Reminder letters were considered by participants to be useful and appeared to influence women's decisions to undergo mammography screening.

  20. SU-E-I-59: Investigation of the Usefulness of a Standard Deviation and Mammary Gland Density as Indexes for Mammogram Classification.

    PubMed

    Takarabe, S; Yabuuchi, H; Morishita, J

    2012-06-01

    To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.

  1. Responses of Cloud Type Distributions to the Large-Scale Dynamical Circulation: Water Budget-Related Dynamical Phase Space and Dynamical Regimes

    NASA Technical Reports Server (NTRS)

    Wong, Sun; Del Genio, Anthony; Wang, Tao; Kahn, Brian; Fetzer, Eric J.; L'Ecuyer, Tristan S.

    2015-01-01

    Goals: Water budget-related dynamical phase space; Connect large-scale dynamical conditions to atmospheric water budget (including precipitation); Connect atmospheric water budget to cloud type distributions.

  2. Implications of the IRAS data for galactic gamma-ray astronomy and EGRET

    NASA Technical Reports Server (NTRS)

    Stecker, F. W.

    1990-01-01

    Using the results of gamma-ray, millimeter wave and far infrared surveys of the galaxy, one can derive a logically consistent picture of the large scale distribution of galactic gas and cosmic rays, one tied to the overall processes of stellar birth and destruction on a galactic scale. Using the results of the IRAS far-infrared survey of the galaxy, the large scale radial distribution of galactic far-infrared emission were obtained independently for both the Northern and Southern Hemisphere sides of the Galaxy. It was found that the dominant feature in these distributions to be a broad peak coincident with the 5 kpc molecular gas cloud ring. Also found was evidence of spiral arm features. Strong correlations are evident between the large scale galactic distributions of far infrared emission, gamma-ray emission and total CO emission. There is a particularly tight correlation between the distribution of warm molecular clouds and far-infrared emission on a galactic scale.

  3. The distribution of free electrons in the inner galaxy from pulsar dispersion measures

    NASA Technical Reports Server (NTRS)

    Harding, D. S.; Harding, A. K.

    1981-01-01

    The dispersion measures of a sample of 149 pulsars in the inner Galaxy (absolute value of l 50 deg) were statistically analyzed to deduce the large-scale distribution of free thermal electrons in this region. The dispersion measure distribution of these pulsars shows significant evidence for a decrease in the electron scale height from a local value greater than the pulsar scale height to a value less than the pulsar scale height at galactocentric radii inside of approximately 7 kpc. An increase in the electron density (to a value around .15/cu cm at 4 to 5 kpc) must accompany such a decrease in scale height. There is also evidence for a large-scale warp in the electron distribution below the b + 0 deg plane inside the Solar circle. A model is proposed for the electron distribution which incorporates these features and Monte Carlo generated dispersion measure distributions are presented for parameters which best reproduce the observed pulsar distributions.

  4. Formation of large-scale structure from cosmic strings and massive neutrinos

    NASA Technical Reports Server (NTRS)

    Scherrer, Robert J.; Melott, Adrian L.; Bertschinger, Edmund

    1989-01-01

    Numerical simulations of large-scale structure formation from cosmic strings and massive neutrinos are described. The linear power spectrum in this model resembles the cold-dark-matter power spectrum. Galaxy formation begins early, and the final distribution consists of isolated density peaks embedded in a smooth background, leading to a natural bias in the distribution of luminous matter. The distribution of clustered matter has a filamentary appearance with large voids.

  5. Resurrecting hot dark matter - Large-scale structure from cosmic strings and massive neutrinos

    NASA Technical Reports Server (NTRS)

    Scherrer, Robert J.

    1988-01-01

    These are the results of a numerical simulation of the formation of large-scale structure from cosmic-string loops in a universe dominated by massive neutrinos (hot dark matter). This model has several desirable features. The final matter distribution contains isolated density peaks embedded in a smooth background, producing a natural bias in the distribution of luminous matter. Because baryons can accrete onto the cosmic strings before the neutrinos, the galaxies will have baryon cores and dark neutrino halos. Galaxy formation in this model begins much earlier than in random-phase models. On large scales the distribution of clustered matter visually resembles the CfA survey, with large voids and filaments.

  6. Supporting large scale applications on networks of workstations

    NASA Technical Reports Server (NTRS)

    Cooper, Robert; Birman, Kenneth P.

    1989-01-01

    Distributed applications on networks of workstations are an increasingly common way to satisfy computing needs. However, existing mechanisms for distributed programming exhibit poor performance and reliability as application size increases. Extension of the ISIS distributed programming system to support large scale distributed applications by providing hierarchical process groups is discussed. Incorporation of hierarchy in the program structure and exploitation of this to limit the communication and storage required in any one component of the distributed system is examined.

  7. Association between mammogram density and background parenchymal enhancement of breast MRI

    NASA Astrophysics Data System (ADS)

    Aghaei, Faranak; Danala, Gopichandh; Wang, Yunzhi; Zarafshani, Ali; Qian, Wei; Liu, Hong; Zheng, Bin

    2018-02-01

    Breast density has been widely considered as an important risk factor for breast cancer. The purpose of this study is to examine the association between mammogram density results and background parenchymal enhancement (BPE) of breast MRI. A dataset involving breast MR images was acquired from 65 high-risk women. Based on mammography density (BIRADS) results, the dataset was divided into two groups of low and high breast density cases. The Low-Density group has 15 cases with mammographic density (BIRADS 1 and 2), while the High-density group includes 50 cases, which were rated by radiologists as mammographic density BIRADS 3 and 4. A computer-aided detection (CAD) scheme was applied to segment and register breast regions depicted on sequential images of breast MRI scans. CAD scheme computed 20 global BPE features from the entire two breast regions, separately from the left and right breast region, as well as from the bilateral difference between left and right breast regions. An image feature selection method namely, CFS method, was applied to remove the most redundant features and select optimal features from the initial feature pool. Then, a logistic regression classifier was built using the optimal features to predict the mammogram density from the BPE features. Using a leave-one-case-out validation method, the classifier yields the accuracy of 82% and area under ROC curve, AUC=0.81+/-0.09. Also, the box-plot based analysis shows a negative association between mammogram density results and BPE features in the MRI images. This study demonstrated a negative association between mammogram density and BPE of breast MRI images.

  8. Effect of cost-sharing reductions on preventive service use among Medicare fee-for-service beneficiaries.

    PubMed

    Goodwin, Suzanne M; Anderson, Gerard F

    2012-01-01

    Section 4104 of the Patient Protection and Affordable Care Act (ACA) waives previous cost-sharing requirements for many Medicare-covered preventive services. In 1997, Congress passed similar legislation waiving the deductible only for mammograms and Pap smears. The purpose of this study is to examine the effect of the deductible waiver on mammogram and Pap smear utilization rates. Using 1995-2003 Medicare claims from a sample of female, elderly Medicare fee-for-service beneficiaries, two pre/post analyses were conducted comparing mammogram and Pap smear utilization rates before and after implementation of the deductible waiver. Receipt of screening mammograms and Pap smears served as the outcome measures, and two time measures, representing two post-test observation periods, were used to examine the short- and long-term impacts on utilization. There was a 20 percent short-term and a 25 percent longer term increase in the probability of having had a mammogram in the four years following the 1997 deductible waiver. Beneficiaries were no more likely to receive a Pap smear following the deductible waiver. Elimination of cost sharing may be an effective strategy for increasing preventive service use, but the impact could depend on the characteristics of the procedure, its cost, and the disease and populations it targets. These historical findings suggest that, with implementation of Section 4104, the greatest increases in utilization will be seen for preventive services that screen for diseases with high incidence or prevalence rates that increase with age, that are expensive, and that are performed on a frequent basis.

  9. Mammography screening in single older African-American women: a study of related factors.

    PubMed

    Zhu, K; Hunter, S; Bernard, L J; Payne-Wilks, K; Roland, C L; Levine, R S

    2000-01-01

    Using baseline data from an intervention study, we examined cognitive, psychological, social and medical care factors in relation to the use of a mammogram in the preceding year among single African-American women aged 65 and older. Study subjects were 325 African-American women aged 65 and older who were divorced, widowed, separated or never-married, and lived in ten public housing complexes in Nashville, Tennessee. In-person interviews were conducted to collect information on breast screening behavior, knowledge and attitude, social network and activities, emotional and psychological symptoms and signs, and medical care use. Compared with those who had not had a mammogram in the preceding year, women who had had a mammogram in the preceding year were three times more likely to have a regular doctor (95% confidence interval [CI] 1.4-5.0) and about six times more likely to have a doctor's recommendation for a mammogram (95%CI 3.4-11.1). In addition, they were more likely to: (a) have attended a meeting on breast health or received educational materials on breast cancer; (b) agree that a woman needs a mammogram even though she has no breast problem; (c) agree that a woman can have breast cancer without having symptoms; (d) have living children and grandchildren; and (e) attend social activities more frequently. While access to regular medical care and receiving a physician's recommendation are strongly associated with mammography among these older, single African-American women, education on breast health and social networks also appear to be influential.

  10. Do cultural factors predict mammography behaviour among Korean immigrants in the USA?

    PubMed

    Lee, Hanju; Kim, Jiyun; Han, Hae-Ra

    2009-12-01

    This paper is a report of a study of the correlates of mammogram use among Korean American women. Despite the increasing incidence of and mortality from breast cancer, Asian women in the United States of America report consistently low rates of mammography screening. A number of health beliefs and sociodemographic characteristics have been associated with mammogram participation among these women. However, studies systematically investigating cultural factors in relation to mammogram experience have been scarce. We measured screening-related health beliefs, modesty and use of Eastern medicine in 100 Korean American women in 2006. Hierarchical logistic regression was used to examine the unique contribution of the study variables, after accounting for sociodemographic characteristics. Only 51% reported past mammogram use. Korean American women who had previously had mammograms were statistically significantly older and had higher perceived benefit scores than those who had not. Perceived benefits (odds ratio = 6.3, 95% confidence interval = 2.12, 18.76) and breast cancer susceptibility (odds ratio = 3.18, 95% confidence interval = 1.06, 9.59) were statistically significant correlates of mammography experience, whereas cultural factors did not correlate. Post hoc analysis showed that for women with some or good English skills, cultural factors statistically significantly correlated with health beliefs and breast cancer knowledge (P < 0.05). Nurses should consider the inclusion in culturally tailored interventions of more targeted outreach and healthcare system navigation assistance for promoting mammography screening in Korean American women. Further research is needed to unravel the interplay between acculturation, cultural factors and health beliefs related to cancer screening behaviours of Korean American women.

  11. Mesh-free based variational level set evolution for breast region segmentation and abnormality detection using mammograms.

    PubMed

    Kashyap, Kanchan L; Bajpai, Manish K; Khanna, Pritee; Giakos, George

    2018-01-01

    Automatic segmentation of abnormal region is a crucial task in computer-aided detection system using mammograms. In this work, an automatic abnormality detection algorithm using mammographic images is proposed. In the preprocessing step, partial differential equation-based variational level set method is used for breast region extraction. The evolution of the level set method is done by applying mesh-free-based radial basis function (RBF). The limitation of mesh-based approach is removed by using mesh-free-based RBF method. The evolution of variational level set function is also done by mesh-based finite difference method for comparison purpose. Unsharp masking and median filtering is used for mammogram enhancement. Suspicious abnormal regions are segmented by applying fuzzy c-means clustering. Texture features are extracted from the segmented suspicious regions by computing local binary pattern and dominated rotated local binary pattern (DRLBP). Finally, suspicious regions are classified as normal or abnormal regions by means of support vector machine with linear, multilayer perceptron, radial basis, and polynomial kernel function. The algorithm is validated on 322 sample mammograms of mammographic image analysis society (MIAS) and 500 mammograms from digital database for screening mammography (DDSM) datasets. Proficiency of the algorithm is quantified by using sensitivity, specificity, and accuracy. The highest sensitivity, specificity, and accuracy of 93.96%, 95.01%, and 94.48%, respectively, are obtained on MIAS dataset using DRLBP feature with RBF kernel function. Whereas, the highest 92.31% sensitivity, 98.45% specificity, and 96.21% accuracy are achieved on DDSM dataset using DRLBP feature with RBF kernel function. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Understanding the patient-provider communication needs and experiences of Latina and non-Latina White women following an abnormal mammogram.

    PubMed

    Molina, Yamile; Hohl, Sarah D; Ko, Linda K; Rodriguez, Edgar A; Thompson, Beti; Beresford, Shirley A A

    2014-12-01

    Latinas are more likely to delay recommended follow-up care than non-Latina White (NLW) women after an abnormal mammogram result. Ethnic differences in communication needs and experiences with health-care staff and providers may contribute to these delays as well as satisfaction with care. Nonetheless, little research has explored the aspects of communication that may contribute to patient comprehension, adherence to follow-up care, and satisfaction across ethnicity. The purpose of this exploratory, qualitative study was to identify patients' communication needs and experiences with follow-up care among Latina and NLW women who received an abnormal mammogram. We conducted 41 semi-structured interviews with 19 Latina and 22 NLW women between the ages of 40 and 74 who had received an abnormal mammogram. Communication themes indicated that women's needs and experiences concerning abnormal mammograms and follow-up care varied across ethnicity. Latinas and NLW women appeared to differ in their comprehension of abnormal results and follow-up care as a result of language barriers and health literacy. Both groups of women identified clear, empathic communication as being important in patient-provider communication; however, Latinas underscored the need for warm communicative styles, and NLW women emphasized the importance of providing more information. Women with high levels of satisfaction with patient-provider interactions appeared to have positive perspectives of subsequent screening and cancer treatment. To improve patient satisfaction and adherence to follow-up care among Latinas, educational programs are necessary to counsel health-care professionals with regard to language, health literacy, and empathic communication needs in health-care service delivery.

  13. Community Partnerships, Food Pantries, and an Evidence-Based Intervention to Increase Mammography among Rural Women

    ERIC Educational Resources Information Center

    Bencivenga, Marcyann; DeRubis, Susan; Leach, Patricia; Lotito, Lisa; Shoemaker, Charles; Lengerich, Eugene J.

    2008-01-01

    Context: Multiple national agencies and organizations recommend that women age 40 years and older have an annual screening mammogram. Women who are poor, less educated, lack a usual source of care, and reside in rural Appalachia are less likely to have had a recent mammogram. Purpose: To increase use of mammography among a rural Appalachian…

  14. Accuracy improvement in laser stripe extraction for large-scale triangulation scanning measurement system

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Liu, Wei; Li, Xiaodong; Yang, Fan; Gao, Peng; Jia, Zhenyuan

    2015-10-01

    Large-scale triangulation scanning measurement systems are widely used to measure the three-dimensional profile of large-scale components and parts. The accuracy and speed of the laser stripe center extraction are essential for guaranteeing the accuracy and efficiency of the measuring system. However, in the process of large-scale measurement, multiple factors can cause deviation of the laser stripe center, including the spatial light intensity distribution, material reflectivity characteristics, and spatial transmission characteristics. A center extraction method is proposed for improving the accuracy of the laser stripe center extraction based on image evaluation of Gaussian fitting structural similarity and analysis of the multiple source factors. First, according to the features of the gray distribution of the laser stripe, evaluation of the Gaussian fitting structural similarity is estimated to provide a threshold value for center compensation. Then using the relationships between the gray distribution of the laser stripe and the multiple source factors, a compensation method of center extraction is presented. Finally, measurement experiments for a large-scale aviation composite component are carried out. The experimental results for this specific implementation verify the feasibility of the proposed center extraction method and the improved accuracy for large-scale triangulation scanning measurements.

  15. Breast Density Awareness and Knowledge, and Intentions for Breast Cancer Screening in a Diverse Sample of Women Age Eligible for Mammography.

    PubMed

    Santiago-Rivas, Marimer; Benjamin, Shayna; Andrews, Janna Z; Jandorf, Lina

    2017-08-14

    The objectives of this study were to assess breast density knowledge and breast density awareness, and to identify information associated with intention to complete routine and supplemental screening for breast cancer in a diverse sample of women age eligible for mammography. We quantitatively (self-report) assessed breast density awareness and knowledge (N = 264) in black (47.7%), Latina (35.2%), and white (17%) women recruited online and in the community. Most participants reported having heard about breast density (69.2%); less than one third knew their own breast density status (30.4%). Knowing their own breast density, believing that women should be notified of their breast density in their mammogram report, and feeling informed if being provided this information are associated with likelihood of completing mammogram. Intending mammogram completion and knowledge regarding the impact of breast density on mammogram accuracy are associated with likelihood of completing supplemental ultrasound tests of the breast. These findings help inform practitioners and policy makers about information and communication factors that influence breast cancer screening concerns and decisions. Knowing this information should prepare practitioners to better identify women who may have not been exposed to breast density messages.

  16. Variable size computer-aided detection prompts and mammography film reader decisions

    PubMed Central

    Gilbert, Fiona J; Astley, Susan M; Boggis, Caroline RM; McGee, Magnus A; Griffiths, Pamela M; Duffy, Stephen W; Agbaje, Olorunsola F; Gillan, Maureen GC; Wilson, Mary; Jain, Anil K; Barr, Nicola; Beetles, Ursula M; Griffiths, Miriam A; Johnson, Jill; Roberts, Rita M; Deans, Heather E; Duncan, Karen A; Iyengar, Geeta

    2008-01-01

    Introduction The purpose of the present study was to investigate the effect of computer-aided detection (CAD) prompts on reader behaviour in a large sample of breast screening mammograms by analysing the relationship of the presence and size of prompts to the recall decision. Methods Local research ethics committee approval was obtained; informed consent was not required. Mammograms were obtained from women attending routine mammography at two breast screening centres in 1996. Films, previously double read, were re-read by a different reader using CAD. The study material included 315 cancer cases comprising all screen-detected cancer cases, all subsequent interval cancers and 861 normal cases randomly selected from 10,267 cases. Ground truth data were used to assess the efficacy of CAD prompting. Associations between prompt attributes and tumour features or reader recall decisions were assessed by chi-squared tests. Results There was a highly significant relationship between prompting and a decision to recall for cancer cases and for a random sample of normal cases (P < 0.001). Sixty-four per cent of all cases contained at least one CAD prompt. In cancer cases, larger prompts were more likely to be recalled (P = 0.02) for masses but there was no such association for calcifications (P = 0.9). In a random sample of 861 normal cases, larger prompts were more likely to be recalled (P = 0.02) for both mass and calcification prompts. Significant associations were observed with prompting and breast density (p = 0.009) for cancer cases but not for normal cases (P = 0.05). Conclusions For both normal cases and cancer cases, prompted mammograms were more likely to be recalled and the prompt size was also associated with a recall decision. PMID:18724867

  17. Understanding Clinical Mammographic Breast Density Assessment: a Deep Learning Perspective.

    PubMed

    Mohamed, Aly A; Luo, Yahong; Peng, Hong; Jankowitz, Rachel C; Wu, Shandong

    2017-09-20

    Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categories (i.e., fatty, scattered density, heterogeneously dense, or extremely dense). In each mammogram examination, a breast is typically imaged with two different views, i.e., the mediolateral oblique (MLO) view and cranial caudal (CC) view. The BI-RADS-based breast density assessment is a qualitative process made by visual observation of both the MLO and CC views by radiologists, where there is a notable inter- and intra-reader variability. In order to maintain consistency and accuracy in BI-RADS-based breast density assessment, gaining understanding on radiologists' reading behaviors will be educational. In this study, we proposed to leverage the newly emerged deep learning approach to investigate how the MLO and CC view images of a mammogram examination may have been clinically used by radiologists in coming up with a BI-RADS density category. We implemented a convolutional neural network (CNN)-based deep learning model, aimed at distinguishing the breast density categories using a large (15,415 images) set of real-world clinical mammogram images. Our results showed that the classification of density categories (in terms of area under the receiver operating characteristic curve) using MLO view images is significantly higher than that using the CC view. This indicates that most likely it is the MLO view that the radiologists have predominately used to determine the breast density BI-RADS categories. Our study holds a potential to further interpret radiologists' reading characteristics, enhance personalized clinical training to radiologists, and ultimately reduce reader variations in breast density assessment.

  18. Variable size computer-aided detection prompts and mammography film reader decisions.

    PubMed

    Gilbert, Fiona J; Astley, Susan M; Boggis, Caroline Rm; McGee, Magnus A; Griffiths, Pamela M; Duffy, Stephen W; Agbaje, Olorunsola F; Gillan, Maureen Gc; Wilson, Mary; Jain, Anil K; Barr, Nicola; Beetles, Ursula M; Griffiths, Miriam A; Johnson, Jill; Roberts, Rita M; Deans, Heather E; Duncan, Karen A; Iyengar, Geeta

    2008-01-01

    The purpose of the present study was to investigate the effect of computer-aided detection (CAD) prompts on reader behaviour in a large sample of breast screening mammograms by analysing the relationship of the presence and size of prompts to the recall decision. Local research ethics committee approval was obtained; informed consent was not required. Mammograms were obtained from women attending routine mammography at two breast screening centres in 1996. Films, previously double read, were re-read by a different reader using CAD. The study material included 315 cancer cases comprising all screen-detected cancer cases, all subsequent interval cancers and 861 normal cases randomly selected from 10,267 cases. Ground truth data were used to assess the efficacy of CAD prompting. Associations between prompt attributes and tumour features or reader recall decisions were assessed by chi-squared tests. There was a highly significant relationship between prompting and a decision to recall for cancer cases and for a random sample of normal cases (P < 0.001). Sixty-four per cent of all cases contained at least one CAD prompt. In cancer cases, larger prompts were more likely to be recalled (P = 0.02) for masses but there was no such association for calcifications (P = 0.9). In a random sample of 861 normal cases, larger prompts were more likely to be recalled (P = 0.02) for both mass and calcification prompts. Significant associations were observed with prompting and breast density (p = 0.009) for cancer cases but not for normal cases (P = 0.05). For both normal cases and cancer cases, prompted mammograms were more likely to be recalled and the prompt size was also associated with a recall decision.

  19. Mass detection in digital breast tomosynthesis: Deep convolutional neural network with transfer learning from mammography

    PubMed Central

    Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A.; Wei, Jun; Cha, Kenny

    2016-01-01

    Purpose: Develop a computer-aided detection (CAD) system for masses in digital breast tomosynthesis (DBT) volume using a deep convolutional neural network (DCNN) with transfer learning from mammograms. Methods: A data set containing 2282 digitized film and digital mammograms and 324 DBT volumes were collected with IRB approval. The mass of interest on the images was marked by an experienced breast radiologist as reference standard. The data set was partitioned into a training set (2282 mammograms with 2461 masses and 230 DBT views with 228 masses) and an independent test set (94 DBT views with 89 masses). For DCNN training, the region of interest (ROI) containing the mass (true positive) was extracted from each image. False positive (FP) ROIs were identified at prescreening by their previously developed CAD systems. After data augmentation, a total of 45 072 mammographic ROIs and 37 450 DBT ROIs were obtained. Data normalization and reduction of non-uniformity in the ROIs across heterogeneous data was achieved using a background correction method applied to each ROI. A DCNN with four convolutional layers and three fully connected (FC) layers was first trained on the mammography data. Jittering and dropout techniques were used to reduce overfitting. After training with the mammographic ROIs, all weights in the first three convolutional layers were frozen, and only the last convolution layer and the FC layers were randomly initialized again and trained using the DBT training ROIs. The authors compared the performances of two CAD systems for mass detection in DBT: one used the DCNN-based approach and the other used their previously developed feature-based approach for FP reduction. The prescreening stage was identical in both systems, passing the same set of mass candidates to the FP reduction stage. For the feature-based CAD system, 3D clustering and active contour method was used for segmentation; morphological, gray level, and texture features were extracted and merged with a linear discriminant classifier to score the detected masses. For the DCNN-based CAD system, ROIs from five consecutive slices centered at each candidate were passed through the trained DCNN and a mass likelihood score was generated. The performances of the CAD systems were evaluated using free-response ROC curves and the performance difference was analyzed using a non-parametric method. Results: Before transfer learning, the DCNN trained only on mammograms with an AUC of 0.99 classified DBT masses with an AUC of 0.81 in the DBT training set. After transfer learning with DBT, the AUC improved to 0.90. For breast-based CAD detection in the test set, the sensitivity for the feature-based and the DCNN-based CAD systems was 83% and 91%, respectively, at 1 FP/DBT volume. The difference between the performances for the two systems was statistically significant (p-value < 0.05). Conclusions: The image patterns learned from the mammograms were transferred to the mass detection on DBT slices through the DCNN. This study demonstrated that large data sets collected from mammography are useful for developing new CAD systems for DBT, alleviating the problem and effort of collecting entirely new large data sets for the new modality. PMID:27908154

  20. Region-growing approach to detect microcalcifications in digital mammograms

    NASA Astrophysics Data System (ADS)

    Shin, Jin-Wook; Chae, Soo-Ik; Sook, Yoon M.; Park, Dong-Sun

    2001-09-01

    Detecting early symptoms of breast cancer is very important to enhance the possibility of cure. There have been active researches to develop computer-aided diagnosis(CAD) systems detecting early symptoms of breast cancer in digital mammograms. An expert or a CAD system can recognize the early symptoms based on microcalcifications appeared in digital mammographic images. Microcalcifications have higher gray value than surrounding regions, so these can be detected by expanding a region from a local maximum. However the resultant image contains unnecessary elements such as noise, holes and valleys. Mathematical morphology is a good solution to delete regions that are affected by the unnecessary elements. In this paper, we present a method that effectively detects microcalcifications in digital mammograms using a combination of local maximum operation and the region-growing operation.

  1. Travel Times for Screening Mammography: Impact of Geographic Expansion by a Large Academic Health System.

    PubMed

    Rosenkrantz, Andrew B; Liang, Yu; Duszak, Richard; Recht, Michael P

    2017-09-01

    This study aims to assess the impact of off-campus facility expansion by a large academic health system on patient travel times for screening mammography. Screening mammograms performed from 2013 to 2015 and associated patient demographics were identified using the NYU Langone Medical Center Enterprise Data Warehouse. During this time, the system's number of mammography facilities increased from 6 to 19, reflecting expansion beyond Manhattan throughout the New York metropolitan region. Geocoding software was used to estimate driving times from patients' homes to imaging facilities. For 147,566 screening mammograms, the mean estimated patient travel time was 19.9 ± 15.2 minutes. With facility expansion, travel times declined significantly (P < 0.001) from 26.8 ± 18.9 to 18.5 ± 13.3 minutes (non-Manhattan residents: from 31.4 ± 20.3 to 18.7 ± 13.6). This decline occurred consistently across subgroups of patient age, race, ethnicity, payer status, and rurality, leading to decreased variation in travel times between such subgroups. However, travel times to pre-expansion facilities remained stable (initial: 26.8 ± 18.9 minutes, final: 26.7 ± 18.6 minutes). Among women undergoing mammography before and after expansion, travel times were shorter for the postexpansion mammogram in only 6.3%, but this rate varied significantly (all P < 0.05) by certain demographic factors (higher in younger and non-Hispanic patients) and was as high as 18.2%-18.9% of patients residing in regions with the most active expansion. Health system mammography facility geographic expansion can improve average patient travel burden and reduce travel time variation among sociodemographic populations. Nonetheless, existing patients strongly tend to return to established facilities despite potentially shorter travel time locations, suggesting strong site loyalty. Variation in travel times likely relates to various factors other than facility proximity. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Spatial distribution of GRBs and large scale structure of the Universe

    NASA Astrophysics Data System (ADS)

    Bagoly, Zsolt; Rácz, István I.; Balázs, Lajos G.; Tóth, L. Viktor; Horváth, István

    We studied the space distribution of the starburst galaxies from Millennium XXL database at z = 0.82. We examined the starburst distribution in the classical Millennium I (De Lucia et al. (2006)) using a semi-analytical model for the genesis of the galaxies. We simulated a starburst galaxies sample with Markov Chain Monte Carlo method. The connection between the large scale structures homogenous and starburst groups distribution (Kofman and Shandarin 1998), Suhhonenko et al. (2011), Liivamägi et al. (2012), Park et al. (2012), Horvath et al. (2014), Horvath et al. (2015)) on a defined scale were checked too.

  3. The large-scale distribution of galaxies

    NASA Technical Reports Server (NTRS)

    Geller, Margaret J.

    1989-01-01

    The spatial distribution of galaxies in the universe is characterized on the basis of the six completed strips of the Harvard-Smithsonian Center for Astrophysics redshift-survey extension. The design of the survey is briefly reviewed, and the results are presented graphically. Vast low-density voids similar to the void in Bootes are found, almost completely surrounded by thin sheets of galaxies. Also discussed are the implications of the results for the survey sampling problem, the two-point correlation function of the galaxy distribution, the possibility of detecting large-scale coherent flows, theoretical models of large-scale structure, and the identification of groups and clusters of galaxies.

  4. Computational Simulation of Breast Compression Based on Segmented Breast and Fibroglandular Tissues on Magnetic Resonance Images

    PubMed Central

    Shih, Tzu-Ching; Chen, Jeon-Hor; Liu, Dongxu; Nie, Ke; Sun, Lizhi; Lin, Muqing; Chang, Daniel; Nalcioglu, Orhan; Su, Min-Ying

    2010-01-01

    This study presents a finite element based computational model to simulate the three-dimensional deformation of the breast and the fibroglandular tissues under compression. The simulation was based on 3D MR images of the breast, and the craniocaudal and mediolateral oblique compression as used in mammography was applied. The geometry of whole breast and the segmented fibroglandular tissues within the breast were reconstructed using triangular meshes by using the Avizo® 6.0 software package. Due to the large deformation in breast compression, a finite element model was used to simulate the non-linear elastic tissue deformation under compression, using the MSC.Marc® software package. The model was tested in 4 cases. The results showed a higher displacement along the compression direction compared to the other two directions. The compressed breast thickness in these 4 cases at 60% compression ratio was in the range of 5-7 cm, which is the typical range of thickness in mammography. The projection of the fibroglandular tissue mesh at 60% compression ratio was compared to the corresponding mammograms of two women, and they demonstrated spatially matched distributions. However, since the compression was based on MRI, which has much coarser spatial resolution than the in-plane resolution of mammography, this method is unlikely to generate a synthetic mammogram close to the clinical quality. Whether this model may be used to understand the technical factors that may impact the variations in breast density measurements needs further investigation. Since this method can be applied to simulate compression of the breast at different views and different compression levels, another possible application is to provide a tool for comparing breast images acquired using different imaging modalities – such as MRI, mammography, whole breast ultrasound, and molecular imaging – that are performed using different body positions and different compression conditions. PMID:20601773

  5. Computational simulation of breast compression based on segmented breast and fibroglandular tissues on magnetic resonance images.

    PubMed

    Shih, Tzu-Ching; Chen, Jeon-Hor; Liu, Dongxu; Nie, Ke; Sun, Lizhi; Lin, Muqing; Chang, Daniel; Nalcioglu, Orhan; Su, Min-Ying

    2010-07-21

    This study presents a finite element-based computational model to simulate the three-dimensional deformation of a breast and fibroglandular tissues under compression. The simulation was based on 3D MR images of the breast, and craniocaudal and mediolateral oblique compression, as used in mammography, was applied. The geometry of the whole breast and the segmented fibroglandular tissues within the breast were reconstructed using triangular meshes by using the Avizo 6.0 software package. Due to the large deformation in breast compression, a finite element model was used to simulate the nonlinear elastic tissue deformation under compression, using the MSC.Marc software package. The model was tested in four cases. The results showed a higher displacement along the compression direction compared to the other two directions. The compressed breast thickness in these four cases at a compression ratio of 60% was in the range of 5-7 cm, which is a typical range of thickness in mammography. The projection of the fibroglandular tissue mesh at a compression ratio of 60% was compared to the corresponding mammograms of two women, and they demonstrated spatially matched distributions. However, since the compression was based on magnetic resonance imaging (MRI), which has much coarser spatial resolution than the in-plane resolution of mammography, this method is unlikely to generate a synthetic mammogram close to the clinical quality. Whether this model may be used to understand the technical factors that may impact the variations in breast density needs further investigation. Since this method can be applied to simulate compression of the breast at different views and different compression levels, another possible application is to provide a tool for comparing breast images acquired using different imaging modalities--such as MRI, mammography, whole breast ultrasound and molecular imaging--that are performed using different body positions and under different compression conditions.

  6. Automatic detection of anomalies in screening mammograms

    PubMed Central

    2013-01-01

    Background Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. Methods In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. Results The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Conclusions Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%. PMID:24330643

  7. A Functional Model for Management of Large Scale Assessments.

    ERIC Educational Resources Information Center

    Banta, Trudy W.; And Others

    This functional model for managing large-scale program evaluations was developed and validated in connection with the assessment of Tennessee's Nutrition Education and Training Program. Management of such a large-scale assessment requires the development of a structure for the organization; distribution and recovery of large quantities of…

  8. Ecological niche modeling as a new paradigm for large-scale investigations of diversity and distribution of birds

    Treesearch

    A. Townsend Peterson; Daniel A. Kluza

    2005-01-01

    Large-scale assessments of the distribution and diversity of birds have been challenged by the need for a robust methodology for summarizing or predicting species' geographic distributions (e.g. Beard et al. 1999, Manel et al. 1999, Saveraid et al. 2001). Methodologies used in such studies have at times been inappropriate, or even more frequently limited in their...

  9. Numerical Simulations of Vortical Mode Stirring: Effects of Large Scale Shear and Strain

    DTIC Science & Technology

    2015-09-30

    Numerical Simulations of Vortical Mode Stirring: Effects of Large-Scale Shear and Strain M.-Pascale Lelong NorthWest Research Associates...can be implemented in larger-scale ocean models. These parameterizations will incorporate the effects of local ambient conditions including latitude...talk at the 1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Nonlinear Effects in Internal Waves Conference held

  10. Statistical analysis of mesoscale rainfall: Dependence of a random cascade generator on large-scale forcing

    NASA Technical Reports Server (NTRS)

    Over, Thomas, M.; Gupta, Vijay K.

    1994-01-01

    Under the theory of independent and identically distributed random cascades, the probability distribution of the cascade generator determines the spatial and the ensemble properties of spatial rainfall. Three sets of radar-derived rainfall data in space and time are analyzed to estimate the probability distribution of the generator. A detailed comparison between instantaneous scans of spatial rainfall and simulated cascades using the scaling properties of the marginal moments is carried out. This comparison highlights important similarities and differences between the data and the random cascade theory. Differences are quantified and measured for the three datasets. Evidence is presented to show that the scaling properties of the rainfall can be captured to the first order by a random cascade with a single parameter. The dependence of this parameter on forcing by the large-scale meteorological conditions, as measured by the large-scale spatial average rain rate, is investigated for these three datasets. The data show that this dependence can be captured by a one-to-one function. Since the large-scale average rain rate can be diagnosed from the large-scale dynamics, this relationship demonstrates an important linkage between the large-scale atmospheric dynamics and the statistical cascade theory of mesoscale rainfall. Potential application of this research to parameterization of runoff from the land surface and regional flood frequency analysis is briefly discussed, and open problems for further research are presented.

  11. Closing the Gap in Mammogram Screening: An Experimental Intervention among Low-Income Hispanic Women in Community Health Clinics

    ERIC Educational Resources Information Center

    Deavenport, Alexis; Modeste, Naomi; Marshak, Helen Hopp; Neish, Christine

    2011-01-01

    A low rate of mammogram screening exists among low-income Hispanic women. To address this disparity, an experimental intervention containing audiovisual and written media was conducted using the health belief model as a framework. The purpose of this study was to determine if low-income Hispanic women, more than 40 years of age, who received…

  12. Multi-agent based control of large-scale complex systems employing distributed dynamic inference engine

    NASA Astrophysics Data System (ADS)

    Zhang, Daili

    Increasing societal demand for automation has led to considerable efforts to control large-scale complex systems, especially in the area of autonomous intelligent control methods. The control system of a large-scale complex system needs to satisfy four system level requirements: robustness, flexibility, reusability, and scalability. Corresponding to the four system level requirements, there arise four major challenges. First, it is difficult to get accurate and complete information. Second, the system may be physically highly distributed. Third, the system evolves very quickly. Fourth, emergent global behaviors of the system can be caused by small disturbances at the component level. The Multi-Agent Based Control (MABC) method as an implementation of distributed intelligent control has been the focus of research since the 1970s, in an effort to solve the above-mentioned problems in controlling large-scale complex systems. However, to the author's best knowledge, all MABC systems for large-scale complex systems with significant uncertainties are problem-specific and thus difficult to extend to other domains or larger systems. This situation is partly due to the control architecture of multiple agents being determined by agent to agent coupling and interaction mechanisms. Therefore, the research objective of this dissertation is to develop a comprehensive, generalized framework for the control system design of general large-scale complex systems with significant uncertainties, with the focus on distributed control architecture design and distributed inference engine design. A Hybrid Multi-Agent Based Control (HyMABC) architecture is proposed by combining hierarchical control architecture and module control architecture with logical replication rings. First, it decomposes a complex system hierarchically; second, it combines the components in the same level as a module, and then designs common interfaces for all of the components in the same module; third, replications are made for critical agents and are organized into logical rings. This architecture maintains clear guidelines for complexity decomposition and also increases the robustness of the whole system. Multiple Sectioned Dynamic Bayesian Networks (MSDBNs) as a distributed dynamic probabilistic inference engine, can be embedded into the control architecture to handle uncertainties of general large-scale complex systems. MSDBNs decomposes a large knowledge-based system into many agents. Each agent holds its partial perspective of a large problem domain by representing its knowledge as a Dynamic Bayesian Network (DBN). Each agent accesses local evidence from its corresponding local sensors and communicates with other agents through finite message passing. If the distributed agents can be organized into a tree structure, satisfying the running intersection property and d-sep set requirements, globally consistent inferences are achievable in a distributed way. By using different frequencies for local DBN agent belief updating and global system belief updating, it balances the communication cost with the global consistency of inferences. In this dissertation, a fully factorized Boyen-Koller (BK) approximation algorithm is used for local DBN agent belief updating, and the static Junction Forest Linkage Tree (JFLT) algorithm is used for global system belief updating. MSDBNs assume a static structure and a stable communication network for the whole system. However, for a real system, sub-Bayesian networks as nodes could be lost, and the communication network could be shut down due to partial damage in the system. Therefore, on-line and automatic MSDBNs structure formation is necessary for making robust state estimations and increasing survivability of the whole system. A Distributed Spanning Tree Optimization (DSTO) algorithm, a Distributed D-Sep Set Satisfaction (DDSSS) algorithm, and a Distributed Running Intersection Satisfaction (DRIS) algorithm are proposed in this dissertation. Combining these three distributed algorithms and a Distributed Belief Propagation (DBP) algorithm in MSDBNs makes state estimations robust to partial damage in the whole system. Combining the distributed control architecture design and the distributed inference engine design leads to a process of control system design for a general large-scale complex system. As applications of the proposed methodology, the control system design of a simplified ship chilled water system and a notional ship chilled water system have been demonstrated step by step. Simulation results not only show that the proposed methodology gives a clear guideline for control system design for general large-scale complex systems with dynamic and uncertain environment, but also indicate that the combination of MSDBNs and HyMABC can provide excellent performance for controlling general large-scale complex systems.

  13. Mammographic screening for breast cancer in a resource-restricted environment.

    PubMed

    Apffelstaedt, S P; Dalmayer, L; Baatjes, K

    2014-04-01

    Mammographic screening is carried out at public sector hospitals as part of clinical practice. We report the experience of such screening at Tygerberg Academic Hospital (TBAH), a tertiary referral hospital in the Western Cape Province, South Africa. All mammograms performed between 2003 and 2012 at TBAH were analysed regarding patient demographics, clinical data, indication and outcome according to the American College of Radiology Breast Imaging Reporting and Data System (BIRADS). Screening mammography was offered to patients > 40 years of age and mammograms were read by experienced breast surgeons. Patients with BIRADS 3 and 4 lesions were recalled for short-term follow-up, further imaging or tissue acquisition. Patients with BIRADS 5 lesions were recalled for tissue acquisition. Further imaging, method of tissue acquisition, histology results and use of neo-adjuvant therapy were also recorded. Of 16 105 mammograms, 3 774 (23.4%) were carried out for screening purposes. The median age of patients undergoing screening was 54 years. Of 407 women with mammograms that were reported as BIRADS 3 - 5 (10.8% of screening mammograms), 187 (46% of recalled women) went on to have further imaging only. Tissue was acquired in 175 patients (43% of recalled women), comprising a biopsy rate of 4.6% of the total series. The malignancy rate in cases in which tissue acquisition was done was 25%. Forty-three breast cancers were diagnosed (11.4/1 000 examinations). Of the cancers, nine (31%) were ductal carcinomas in situ. Of 20 invasive cancers, nine (45%) were < 10 mm in size. Of the invasive cancers, 40% were node-positive. The cancer diagnosis rate indicates a high breast cancer load in an urbanised population.

  14. An Assessment of the Likelihood, Frequency, and Content of Verbal Communication Between Radiologists and Women Receiving Screening and Diagnostic Mammography

    PubMed Central

    Carney, Patricia A.; Kettler, Mark; Cook, Andrea J.; Geller, Berta M.; Karliner, Leah; Miglioretti, Diana L.; Bowles, Erin Aiello; Buist, Diana S.; Gallagher, Thomas H.; Elmore, Joann G.

    2009-01-01

    Rationale & Objective Research on communication between radiologists and women undergoing screening and diagnostic mammography is limited. We describe community radiologists’ communication practices with patients regarding screening and diagnostic mammogram results and factors associated with frequency of communication. Materials & Methods We received surveys from 257 radiologists (70% of those eligible) about the extent to which they talk to women as part of their healthcare visit for either screening or diagnostic mammograms, whether this occurs if the exam assessment is positive or negative, and how they use estimates of patient risk to convey information about an abnormal exam where the specific finding of cancer is not yet known. We also assessed characteristics of the radiologists to identify associations with more or less frequent communication at the time of the mammogram. Results Two hundred and forty-three radiologists provided complete data (95%). Very few (<6%) reported routinely communicating with women when screening mammograms were either normal or abnormal. Less than half (47%) routinely communicated with women when their diagnostic mammograms were normal, while 77% often or always communicated with women when their diagnostic exams were abnormal. For positive diagnostic exams, female radiologists were more likely to be frequent communicators compared to males (87.1% to 72.8%; p-value = 0.02) and those who spend 40-79% of their time in breast imaging (94.6%) were more likely to be frequent communicators compared to those who spend less time (67.2%-78.9%; p-value = 0.02). Most radiologists convey risk information using general rather than numeric statements (57.7% vs. 28.5%). Conclusions Radiologists are most likely to convey information about diagnostic mammographic findings when results are abnormal. Most radiologists convey risk information using general rather than numeric statements. PMID:19442539

  15. The association of social support and education with breast and cervical cancer screening.

    PubMed

    Documet, Patricia; Bear, Todd M; Flatt, Jason D; Macia, Laura; Trauth, Jeanette; Ricci, Edmund M

    2015-02-01

    Disparities in breast and cervical cancer screening by socioeconomic status persist in the United States. It has been suggested that social support may facilitate screening, especially among women of low socioeconomic status. However, at present, it is unclear whether social support enables mammogram and Pap test compliance. This study examines the association between social support and compliance with mammogram and Pap test screening guidelines, and whether social support provides added value for women of low education. Data were from a countywide 2009-2010 population-based survey, which included records of 2,588 women 40 years and older (mammogram) and 2,123 women 21 to 65 years old (Pap test). Compliance was determined using the guidelines in effect at the time of data collection. Social support was significantly related to mammogram (adjusted odds ratio = 1.43; 95% confidence interval [1.16, 1.77]) and Pap test (adjusted odds ratio = 1.71; 95% confidence interval [1.27, 2.29]) compliance after controlling for age, race, having a regular health care provider, and insurance status. The interaction between social support and education had a significant effect on Pap test compliance only among women younger than 40; the effect was not significant for mammogram compliance. Social support is associated with breast and cervical cancer screening compliance. The association between education and cancer screening behavior may be moderated by social support; however, results hold only for Pap tests among younger women. Practitioners and researchers should focus on interventions that activate social support networks as they may help increase both breast and cervical cancer screening compliance among women with low educational attainment. © 2014 Society for Public Health Education.

  16. Frequency and Determinants of a Short-Interval Follow-up Recommendation After an Abnormal Screening Mammogram.

    PubMed

    Pelletier, Eric; Daigle, Jean-Marc; Defay, Fannie; Major, Diane; Guertin, Marie-Hélène; Brisson, Jacques

    2016-11-01

    After imaging assessment of an abnormal screening mammogram, a follow-up examination 6 months later is recommended to some women. Our aim was to identify which characteristics of lesions, women, and physicians are associated to such short-interval follow-up recommendation in the Quebec Breast Cancer Screening Program. Between 1998 and 2008, 1,839,396 screening mammograms were performed and a total of 114,781 abnormal screens were assessed by imaging only. Multivariate analysis was done with multilevel Poisson regression models with robust variance and generalized linear mixed models. A short-interval follow-up was recommended in 26.7% of assessments with imaging only, representing 2.3% of all screens. Case-mix adjusted proportion of short-interval follow-up recommendations varied substantially across physicians (range: 4%-64%). Radiologists with high recall rates (≥15%) had a high proportion of short-interval follow-up recommendation (risk ratio: 1.82; 95% confidence interval: 1.35-2.45) compared to radiologists with low recall rates (<5%). The adjusted proportion of short-interval follow-up was high (22.8%) even when a previous mammogram was usually available. Short-interval follow-up recommendation at assessment is frequent in this Canadian screening program, even when a previous mammogram is available. Characteristics related to radiologists appear to be key determinants of short-interval follow-up recommendation, rather than characteristics of lesions or patient mix. Given that it can cause anxiety to women and adds pressure on the health system, it appears important to record and report short-interval follow-up and to identify ways to reduce its frequency. Short-interval follow-up recommendations should be considered when assessing the burden of mammography screening. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Spatiotemporal property and predictability of large-scale human mobility

    NASA Astrophysics Data System (ADS)

    Zhang, Hai-Tao; Zhu, Tao; Fu, Dongfei; Xu, Bowen; Han, Xiao-Pu; Chen, Duxin

    2018-04-01

    Spatiotemporal characteristics of human mobility emerging from complexity on individual scale have been extensively studied due to the application potential on human behavior prediction and recommendation, and control of epidemic spreading. We collect and investigate a comprehensive data set of human activities on large geographical scales, including both websites browse and mobile towers visit. Numerical results show that the degree of activity decays as a power law, indicating that human behaviors are reminiscent of scale-free random walks known as Lévy flight. More significantly, this study suggests that human activities on large geographical scales have specific non-Markovian characteristics, such as a two-segment power-law distribution of dwelling time and a high possibility for prediction. Furthermore, a scale-free featured mobility model with two essential ingredients, i.e., preferential return and exploration, and a Gaussian distribution assumption on the exploration tendency parameter is proposed, which outperforms existing human mobility models under scenarios of large geographical scales.

  18. Multi-level structure in the large scale distribution of optically luminous galaxies

    NASA Astrophysics Data System (ADS)

    Deng, Xin-fa; Deng, Zu-gan; Liu, Yong-zhen

    1992-04-01

    Fractal dimensions in the large scale distribution of galaxies have been calculated with the method given by Wen et al. [1] Samples are taken from CfA redshift survey in northern and southern galactic [2] hemisphere in our analysis respectively. Results from these two regions are compared with each other. There are significant differences between the distributions in these two regions. However, our analyses do show some common features of the distributions in these two regions. All subsamples show multi-level fractal character distinctly. Combining it with the results from analyses of samples given by IRAS galaxies and results from samples given by redshift survey in pencil-beam fields, [3,4] we suggest that multi-level fractal structure is most likely to be a general and important character in the large scale distribution of galaxies. The possible implications of this character are discussed.

  19. Probing the statistics of primordial fluctuations and their evolution

    NASA Technical Reports Server (NTRS)

    Gaztanaga, Enrique; Yokoyama, Jun'ichi

    1993-01-01

    The statistical distribution of fluctuations on various scales is analyzed in terms of the counts in cells of smoothed density fields, using volume-limited samples of galaxy redshift catalogs. It is shown that the distribution on large scales, with volume average of the two-point correlation function of the smoothed field less than about 0.05, is consistent with Gaussian. Statistics are shown to agree remarkably well with the negative binomial distribution, which has hierarchial correlations and a Gaussian behavior at large scales. If these observed properties correspond to the matter distribution, they suggest that our universe started with Gaussian fluctuations and evolved keeping hierarchial form.

  20. A deep (learning) dive into visual search behaviour of breast radiologists

    NASA Astrophysics Data System (ADS)

    Mall, Suneeta; Brennan, Patrick C.; Mello-Thoms, Claudia

    2018-03-01

    Visual search, the process of detecting and identifying objects using the eye movements (saccades) and the foveal vision, has been studied for identification of root causes of errors in the interpretation of mammography. The aim of this study is to model visual search behaviour of radiologists and their interpretation of mammograms using deep machine learning approaches. Our model is based on a deep convolutional neural network, a biologically-inspired multilayer perceptron that simulates the visual cortex, and is reinforced with transfer learning techniques. Eye tracking data obtained from 8 radiologists (of varying experience levels in reading mammograms) reviewing 120 two-view digital mammography cases (59 cancers) have been used to train the model, which was pre-trained with the ImageNet dataset for transfer learning. Areas of the mammogram that received direct (foveally fixated), indirect (peripherally fixated) or no (never fixated) visual attention were extracted from radiologists' visual search maps (obtained by a head mounted eye tracking device). These areas, along with the radiologists' assessment (including confidence of the assessment) of suspected malignancy were used to model: 1) Radiologists' decision; 2) Radiologists' confidence on such decision; and 3) The attentional level (i.e. foveal, peripheral or none) obtained by an area of the mammogram. Our results indicate high accuracy and low misclassification in modelling such behaviours.

  1. Comparative visualization of digital mammograms on clinical 2K monitor workstations and hardcopy: a contrast detail analysis

    NASA Astrophysics Data System (ADS)

    Torbica, Pavle; Buchberger, Wolfgang; Bernathova, M.; Mallouhi, Ammar; Peer, Siegfried; Bosmans, Hilde; Faulkner, Keith

    2003-05-01

    The purpose of this study was to compare the radiologist`s performance in detecting small low-contrast objects with hardcopy and softcopy reading of digital mammograms. 12 images of a contrast-detail (CD) phantom without and with 25.4 mm, 50.8 mm, and 76.2 mm additional polymethylmetacrylate (PMMA) attenuation were acquired with a caesium iodid/amorphous silicon flat panel detector under standard exposure conditions. The phantom images were read by three independent observers, by conducting a four-alternative forced-choice experiment. Reading of the hardcopy was done on a mammography viewbox under standardized reading conditions. For soft copy reading, a dedicated workstation with two 2K monitors was used. CD-curves and image quality figure (IQF) values were calculated from the correct detection rates of randomly located gold disks in the phantom. The figures were compared for both reading conditions and for different PMMA layers. For all types of exposures, soft copy reading resulted in significantly better contrast-detail characteristics and IQF values, as compared to hard copy reading of laser printouts. (p< 0.01). The authors conclude that the threshold contrast characteristics of digital mammograms displayed on high-resolution monitors are sufficient to make soft copy reading of digital mammograms feasible.

  2. Medical radiologic technologist review: effects on a population-based breast cancer screening program.

    PubMed

    Tonita, J M; Hillis, J P; Lim, C H

    1999-05-01

    To evaluate the effects of medical radiologic technologist review of mammograms in a population-based breast cancer screening program. A technologist review pilot project was incorporated into the Regina, Saskatchewan, Canada, reading center. Technologists received special training in mammographic interpretation. They reviewed all 27,863 mammograms obtained at the center from July 1995 to September 1996 that were reviewed by a radiologist and selected cases for second blind reading by another radiologist. When the two radiologists' readings were in agreement, the report was sent. When the readings differed, a third opinion was obtained from the program's consulting radiologist. Changes in the number of mammograms interpreted as abnormal and the number of cancers detected were assessed. The technologist review was responsible for the detection of nine cancers missed at the first radiologist's interpretation. Technologists were very discriminating; only 391 cases (1.4%) were sent for double reading. The positive predictive value of screening did not change significantly (7.5% without review, 8.1% with review; P > .20). A substantial number of cancers were found with the technologist review. The number of mammograms interpreted as abnormal was reduced slightly. The technologist review proved to be a cost-effective alternative to double reading by two radiologists.

  3. Using x-ray mammograms to assist in microwave breast image interpretation.

    PubMed

    Curtis, Charlotte; Frayne, Richard; Fear, Elise

    2012-01-01

    Current clinical breast imaging modalities include ultrasound, magnetic resonance (MR) imaging, and the ubiquitous X-ray mammography. Microwave imaging, which takes advantage of differing electromagnetic properties to obtain image contrast, shows potential as a complementary imaging technique. As an emerging modality, interpretation of 3D microwave images poses a significant challenge. MR images are often used to assist in this task, and X-ray mammograms are readily available. However, X-ray mammograms provide 2D images of a breast under compression, resulting in significant geometric distortion. This paper presents a method to estimate the 3D shape of the breast and locations of regions of interest from standard clinical mammograms. The technique was developed using MR images as the reference 3D shape with the future intention of using microwave images. Twelve breast shapes were estimated and compared to ground truth MR images, resulting in a skin surface estimation accurate to within an average Euclidean distance of 10 mm. The 3D locations of regions of interest were estimated to be within the same clinical area of the breast as corresponding regions seen on MR imaging. These results encourage investigation into the use of mammography as a source of information to assist with microwave image interpretation as well as validation of microwave imaging techniques.

  4. Family/friend recommendations and mammography intentions: the roles of perceived mammography norms and support

    PubMed Central

    Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.

    2015-01-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [−0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. PMID:26324395

  5. 'Fracking', Induced Seismicity and the Critical Earth

    NASA Astrophysics Data System (ADS)

    Leary, P.; Malin, P. E.

    2012-12-01

    Issues of 'fracking' and induced seismicity are reverse-analogous to the equally complex issues of well productivity in hydrocarbon, geothermal and ore reservoirs. In low hazard reservoir economics, poorly producing wells and low grade ore bodies are many while highly producing wells and high grade ores are rare but high pay. With induced seismicity factored in, however, the same distribution physics reverses the high/low pay economics: large fracture-connectivity systems are hazardous hence low pay, while high probability small fracture-connectivity systems are non-hazardous hence high pay. Put differently, an economic risk abatement tactic for well productivity and ore body pay is to encounter large-scale fracture systems, while an economic risk abatement tactic for 'fracking'-induced seismicity is to avoid large-scale fracture systems. Well productivity and ore body grade distributions arise from three empirical rules for fluid flow in crustal rock: (i) power-law scaling of grain-scale fracture density fluctuations; (ii) spatial correlation between spatial fluctuations in well-core porosity and the logarithm of well-core permeability; (iii) frequency distributions of permeability governed by a lognormality skewness parameter. The physical origin of rules (i)-(iii) is the universal existence of a critical-state-percolation grain-scale fracture-density threshold for crustal rock. Crustal fractures are effectively long-range spatially-correlated distributions of grain-scale defects permitting fluid percolation on mm to km scales. The rule is, the larger the fracture system the more intense the percolation throughput. As percolation pathways are spatially erratic and unpredictable on all scales, they are difficult to model with sparsely sampled well data. Phenomena such as well productivity, induced seismicity, and ore body fossil fracture distributions are collectively extremely difficult to predict. Risk associated with unpredictable reservoir well productivity and ore body distributions can be managed by operating in a context which affords many small failures for a few large successes. In reverse view, 'fracking' and induced seismicity could be rationally managed in a context in which many small successes can afford a few large failures. However, just as there is every incentive to acquire information leading to higher rates of productive well drilling and ore body exploration, there are equal incentives for acquiring information leading to lower rates of 'fracking'-induced seismicity. Current industry practice of using an effective medium approach to reservoir rock creates an uncritical sense that property distributions in rock are essentially uniform. Well-log data show that the reverse is true: the larger the length scale the greater the deviation from uniformity. Applying the effective medium approach to large-scale rock formations thus appears to be unnecessarily hazardous. It promotes the notion that large scale fluid pressurization acts against weakly cohesive but essentially uniform rock to produce large-scale quasi-uniform tensile discontinuities. Indiscriminate hydrofacturing appears to be vastly more problematic in reality than as pictured by the effective medium hypothesis. The spatial complexity of rock, especially at large scales, provides ample reason to find more controlled pressurization strategies for enhancing in situ flow.

  6. A Life-Cycle Model of Human Social Groups Produces a U-Shaped Distribution in Group Size.

    PubMed

    Salali, Gul Deniz; Whitehouse, Harvey; Hochberg, Michael E

    2015-01-01

    One of the central puzzles in the study of sociocultural evolution is how and why transitions from small-scale human groups to large-scale, hierarchically more complex ones occurred. Here we develop a spatially explicit agent-based model as a first step towards understanding the ecological dynamics of small and large-scale human groups. By analogy with the interactions between single-celled and multicellular organisms, we build a theory of group lifecycles as an emergent property of single cell demographic and expansion behaviours. We find that once the transition from small-scale to large-scale groups occurs, a few large-scale groups continue expanding while small-scale groups gradually become scarcer, and large-scale groups become larger in size and fewer in number over time. Demographic and expansion behaviours of groups are largely influenced by the distribution and availability of resources. Our results conform to a pattern of human political change in which religions and nation states come to be represented by a few large units and many smaller ones. Future enhancements of the model should include decision-making rules and probabilities of fragmentation for large-scale societies. We suggest that the synthesis of population ecology and social evolution will generate increasingly plausible models of human group dynamics.

  7. A Life-Cycle Model of Human Social Groups Produces a U-Shaped Distribution in Group Size

    PubMed Central

    Salali, Gul Deniz; Whitehouse, Harvey; Hochberg, Michael E.

    2015-01-01

    One of the central puzzles in the study of sociocultural evolution is how and why transitions from small-scale human groups to large-scale, hierarchically more complex ones occurred. Here we develop a spatially explicit agent-based model as a first step towards understanding the ecological dynamics of small and large-scale human groups. By analogy with the interactions between single-celled and multicellular organisms, we build a theory of group lifecycles as an emergent property of single cell demographic and expansion behaviours. We find that once the transition from small-scale to large-scale groups occurs, a few large-scale groups continue expanding while small-scale groups gradually become scarcer, and large-scale groups become larger in size and fewer in number over time. Demographic and expansion behaviours of groups are largely influenced by the distribution and availability of resources. Our results conform to a pattern of human political change in which religions and nation states come to be represented by a few large units and many smaller ones. Future enhancements of the model should include decision-making rules and probabilities of fragmentation for large-scale societies. We suggest that the synthesis of population ecology and social evolution will generate increasingly plausible models of human group dynamics. PMID:26381745

  8. Architecture and Programming Models for High Performance Intensive Computation

    DTIC Science & Technology

    2016-06-29

    Applications Systems and Large-Scale-Big-Data & Large-Scale-Big-Computing (DDDAS- LS ). ICCS 2015, June 2015. Reykjavk, Ice- land. 2. Bo YT, Wang P, Guo ZL...The Mahali project,” Communications Magazine , vol. 52, pp. 111–133, Aug 2014. 14 DISTRIBUTION A: Distribution approved for public release. Response ID

  9. Large Scale Density Estimation of Blue and Fin Whales: Utilizing Sparse Array Data to Develop and Implement a New Method for Estimating Blue and Fin Whale Density

    DTIC Science & Technology

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Large Scale Density Estimation of Blue and Fin Whales ...Utilizing Sparse Array Data to Develop and Implement a New Method for Estimating Blue and Fin Whale Density Len Thomas & Danielle Harris Centre...to develop and implement a new method for estimating blue and fin whale density that is effective over large spatial scales and is designed to cope

  10. Large-scale geographic variation in distribution and abundance of Australian deep-water kelp forests.

    PubMed

    Marzinelli, Ezequiel M; Williams, Stefan B; Babcock, Russell C; Barrett, Neville S; Johnson, Craig R; Jordan, Alan; Kendrick, Gary A; Pizarro, Oscar R; Smale, Dan A; Steinberg, Peter D

    2015-01-01

    Despite the significance of marine habitat-forming organisms, little is known about their large-scale distribution and abundance in deeper waters, where they are difficult to access. Such information is necessary to develop sound conservation and management strategies. Kelps are main habitat-formers in temperate reefs worldwide; however, these habitats are highly sensitive to environmental change. The kelp Ecklonia radiate is the major habitat-forming organism on subtidal reefs in temperate Australia. Here, we provide large-scale ecological data encompassing the latitudinal distribution along the continent of these kelp forests, which is a necessary first step towards quantitative inferences about the effects of climatic change and other stressors on these valuable habitats. We used the Autonomous Underwater Vehicle (AUV) facility of Australia's Integrated Marine Observing System (IMOS) to survey 157,000 m2 of seabed, of which ca 13,000 m2 were used to quantify kelp covers at multiple spatial scales (10-100 m to 100-1,000 km) and depths (15-60 m) across several regions ca 2-6° latitude apart along the East and West coast of Australia. We investigated the large-scale geographic variation in distribution and abundance of deep-water kelp (>15 m depth) and their relationships with physical variables. Kelp cover generally increased with latitude despite great variability at smaller spatial scales. Maximum depth of kelp occurrence was 40-50 m. Kelp latitudinal distribution along the continent was most strongly related to water temperature and substratum availability. This extensive survey data, coupled with ongoing AUV missions, will allow for the detection of long-term shifts in the distribution and abundance of habitat-forming kelp and the organisms they support on a continental scale, and provide information necessary for successful implementation and management of conservation reserves.

  11. Implications of the IRAS data for galactic gamma ray astronomy and EGRET

    NASA Technical Reports Server (NTRS)

    Stecker, Floyd W.

    1990-01-01

    Using the results of gamma-ray, millimeter wave and far surveys of the galaxy, logically consistent picture of the large scale distribution of galactic gas and cosmic rays was derived, tied to the overall processes of stellar birth and destruction on a galactic scale. Using the results of the IRAS far-infrared survey of te galaxy, the large scale radial distributions of galactic far-infrared emission independently was obtained for both the Northern and Southern Hemisphere sides of the Galaxy. The dominant feature in these distributions was found to be a broad peak coincident with the 5 kpc molecular gas cloud ring. Evidence was found for spiral arm features. Strong correlations are evident between the large scale galactic distributions of far-infrared emission, gamma-ray emission and total CO emission. There is particularly tight correlation between the distribution of warm molecular clouds and far-infrared emission on a galactic scale. The 5 kpc ring was evident in existing galactic gamma-ray data. The extent to which the more detailed spiral arm features are evident in the more resolved EGRET (Energetic Gamma-Ray Experimental Telescope) data will help to determine more precisely the propagation characteristics of cosmic rays.

  12. Mapping spatial patterns of denitrifiers at large scales (Invited)

    NASA Astrophysics Data System (ADS)

    Philippot, L.; Ramette, A.; Saby, N.; Bru, D.; Dequiedt, S.; Ranjard, L.; Jolivet, C.; Arrouays, D.

    2010-12-01

    Little information is available regarding the landscape-scale distribution of microbial communities and its environmental determinants. Here we combined molecular approaches and geostatistical modeling to explore spatial patterns of the denitrifying community at large scales. The distribution of denitrifrying community was investigated over 107 sites in Burgundy, a 31 500 km2 region of France, using a 16 X 16 km sampling grid. At each sampling site, the abundances of denitrifiers and 42 soil physico-chemical properties were measured. The relative contributions of land use, spatial distance, climatic conditions, time and soil physico-chemical properties to the denitrifier spatial distribution were analyzed by canonical variation partitioning. Our results indicate that 43% to 85% of the spatial variation in community abundances could be explained by the measured environmental parameters, with soil chemical properties (mostly pH) being the main driver. We found spatial autocorrelation up to 739 km and used geostatistical modelling to generate predictive maps of the distribution of denitrifiers at the landscape scale. Studying the distribution of the denitrifiers at large scale can help closing the artificial gap between the investigation of microbial processes and microbial community ecology, therefore facilitating our understanding of the relationships between the ecology of denitrifiers and N-fluxes by denitrification.

  13. Robust scalable stabilisability conditions for large-scale heterogeneous multi-agent systems with uncertain nonlinear interactions: towards a distributed computing architecture

    NASA Astrophysics Data System (ADS)

    Manfredi, Sabato

    2016-06-01

    Large-scale dynamic systems are becoming highly pervasive in their occurrence with applications ranging from system biology, environment monitoring, sensor networks, and power systems. They are characterised by high dimensionality, complexity, and uncertainty in the node dynamic/interactions that require more and more computational demanding methods for their analysis and control design, as well as the network size and node system/interaction complexity increase. Therefore, it is a challenging problem to find scalable computational method for distributed control design of large-scale networks. In this paper, we investigate the robust distributed stabilisation problem of large-scale nonlinear multi-agent systems (briefly MASs) composed of non-identical (heterogeneous) linear dynamical systems coupled by uncertain nonlinear time-varying interconnections. By employing Lyapunov stability theory and linear matrix inequality (LMI) technique, new conditions are given for the distributed control design of large-scale MASs that can be easily solved by the toolbox of MATLAB. The stabilisability of each node dynamic is a sufficient assumption to design a global stabilising distributed control. The proposed approach improves some of the existing LMI-based results on MAS by both overcoming their computational limits and extending the applicative scenario to large-scale nonlinear heterogeneous MASs. Additionally, the proposed LMI conditions are further reduced in terms of computational requirement in the case of weakly heterogeneous MASs, which is a common scenario in real application where the network nodes and links are affected by parameter uncertainties. One of the main advantages of the proposed approach is to allow to move from a centralised towards a distributed computing architecture so that the expensive computation workload spent to solve LMIs may be shared among processors located at the networked nodes, thus increasing the scalability of the approach than the network size. Finally, a numerical example shows the applicability of the proposed method and its advantage in terms of computational complexity when compared with the existing approaches.

  14. Mapping the distribution of the denitrifier community at large scales (Invited)

    NASA Astrophysics Data System (ADS)

    Philippot, L.; Bru, D.; Ramette, A.; Dequiedt, S.; Ranjard, L.; Jolivet, C.; Arrouays, D.

    2010-12-01

    Little information is available regarding the landscape-scale distribution of microbial communities and its environmental determinants. Here we combined molecular approaches and geostatistical modeling to explore spatial patterns of the denitrifying community at large scales. The distribution of denitrifrying community was investigated over 107 sites in Burgundy, a 31 500 km2 region of France, using a 16 X 16 km sampling grid. At each sampling site, the abundances of denitrifiers and 42 soil physico-chemical properties were measured. The relative contributions of land use, spatial distance, climatic conditions, time and soil physico-chemical properties to the denitrifier spatial distribution were analyzed by canonical variation partitioning. Our results indicate that 43% to 85% of the spatial variation in community abundances could be explained by the measured environmental parameters, with soil chemical properties (mostly pH) being the main driver. We found spatial autocorrelation up to 740 km and used geostatistical modelling to generate predictive maps of the distribution of denitrifiers at the landscape scale. Studying the distribution of the denitrifiers at large scale can help closing the artificial gap between the investigation of microbial processes and microbial community ecology, therefore facilitating our understanding of the relationships between the ecology of denitrifiers and N-fluxes by denitrification.

  15. Incremental Role of Mammography in the Evaluation of Gynecomastia in Men Who Have Undergone Chest CT.

    PubMed

    Sonnenblick, Emily B; Salvatore, Mary; Szabo, Janet; Lee, Karen A; Margolies, Laurie R

    2016-08-01

    The purpose of this study was to determine whether additional breast imaging is clinically valuable in the evaluation of patients with gynecomastia incidentally observed on CT of the chest. In a retrospective analysis, 62 men were identified who had a mammographic diagnosis of gynecomastia and had also undergone CT within 8 months (median, 2 months). We compared the imaging findings of both modalities and correlated them with the clinical outcome. Gynecomastia was statistically significantly larger on mammograms than on CT images; however, there was a high level of concordance in morphologic features and distribution of gynecomastia between mammography and CT. In only one case was gynecomastia evident on mammographic but not CT images, owing to cachexia. Two of the 62 men had ductal carcinoma, which was obscured by gynecomastia. Both of these patients had symptoms suggesting malignancy. The appearance of gynecomastia on CT scans and mammograms was highly correlated. Mammography performed within 8 months of CT is unlikely to reveal cancer unless there is a suspicious clinical finding or a breast mass eccentric to the nipple. Men with clinical symptoms of gynecomastia do not need additional imaging with mammography to confirm the diagnosis if they have undergone recent cross-sectional imaging.

  16. Women’s cognitive and affective reactions to breast cancer survivor stories: A structural equation analysis

    PubMed Central

    McQueen, Amy; Kreuter, Matthew W.

    2010-01-01

    OBJECTIVE Compare the immediate affective and cognitive reactions to cancer survivor stories about mammography and breast cancer vs. a didactic, informational approach. METHODS Participants (N=489) were African American women age 40 years and older (Mean = 61). Most had ≤ high school education (67%), annual household income ≤ $20,000 (77%), and a prior mammogram (89%). Participants completed surveys before and after watching the narrative or informational video. We used structural equation modeling to examine the large number of inter-related latent constructs. RESULTS Women who watched the narrative video experienced more positive and negative emotions, found it easier to understand the video, had more positive evaluations of the video, reported stronger identification with the message source (i.e., perceived similarity, trust, liking), and were more engaged with the video. CONCLUSIONS Narratives elicited immediate reactions consistent with theorized pathways of how communication affects behavior. Future studies should examine whether and how these immediate outcomes act as mediators of the longer-term effects of narratives on affect, cognitions, and behavior. PRACTICE IMPLICATIONS Stories of other women’s experiences may be more powerful than a didactic presentation when encouraging African American women to get a mammogram. PMID:20850258

  17. Evaluation of the "Angelina Jolie Effect" on Screening Mammography Utilization in an Academic Center.

    PubMed

    Huesch, Marco D; Schetter, Susann; Segel, Joel; Chetlen, Alison

    2017-08-01

    The aim of this study was to understand the impact on screening mammography at our institution, comparing weekly utilization in the 2 years before and the 2 years after Ms Angelina Jolie disclosed in the New York Times on May 13, 2013, that she had had a prophylactic double mastectomy. All 48,110 consecutive screening mammograms conducted at our institution between May 16, 2011, and May 16, 2015, were selected from our electronic medical record system. We used interrupted time series statistical models and graphical methods on utilization data to understand utilization changes before and after Ms Jolie's news. The graphed trend of weekly screening mammogram utilization failed to show changes around the time of interest. Analytical models and statistical tests also failed to show a step change increase or acceleration of utilization around May 2013. However, graphical and time series analyses showed a flattening of utilization in the middle of 2014. In our well-powered analysis in a large regional breast imaging center, we found no support for the hypothesis that this celebrity news drove increased screening. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Performance of distributed multiscale simulations

    PubMed Central

    Borgdorff, J.; Ben Belgacem, M.; Bona-Casas, C.; Fazendeiro, L.; Groen, D.; Hoenen, O.; Mizeranschi, A.; Suter, J. L.; Coster, D.; Coveney, P. V.; Dubitzky, W.; Hoekstra, A. G.; Strand, P.; Chopard, B.

    2014-01-01

    Multiscale simulations model phenomena across natural scales using monolithic or component-based code, running on local or distributed resources. In this work, we investigate the performance of distributed multiscale computing of component-based models, guided by six multiscale applications with different characteristics and from several disciplines. Three modes of distributed multiscale computing are identified: supplementing local dependencies with large-scale resources, load distribution over multiple resources, and load balancing of small- and large-scale resources. We find that the first mode has the apparent benefit of increasing simulation speed, and the second mode can increase simulation speed if local resources are limited. Depending on resource reservation and model coupling topology, the third mode may result in a reduction of resource consumption. PMID:24982258

  19. Shifts in Summertime Precipitation Accumulation Distributions over the US

    NASA Astrophysics Data System (ADS)

    Martinez-Villalobos, C.; Neelin, J. D.

    2016-12-01

    Precipitation accumulations, i.e., the amount of precipitation integrated over the course of an event, is a variable with both important physical and societal implications. Previous observational studies show that accumulation distributions have a characteristic shape, with an approximately power law decrease at first, followed by a sharp decrease at a characteristic large event cutoff scale. This cutoff scale is important as it limits the biggest accumulation events. Stochastic prototypes show that the resulting distributions, and importantly the large event cutoff scale, can be understood as a result of the interplay between moisture loss by precipitation and changes in moisture sinks/sources due to fluctuations in moisture divergence over the course of a precipitation event. The strength of this fluctuating moisture sink/source term is expected to increase under global warming, with both theory and climate model simulations predicting a concomitant increase in the large event cutoff scale. This cutoff scale increase has important consequences as it implies an approximately exponential increase for the largest accumulation events. Given its importance, in this study we characterize and track changes in the distribution of precipitation events accumulations over the contiguous US. Accumulation distributions are calculated using hourly precipitation data from 1700 stations, covering the 1974-2013 period over May-October. The resulting distributions largely follow the aforementioned shape, with individual cutoff scales depending on the local climate. An increase in the large event cutoff scale over this period is observed over several regions over the US, most notably over the eastern third of the US. In agreement with the increase in the cutoff, almost exponential increases in the highest accumulation percentiles occur over these regions, with increases in the 99.9 percentile in the Northeast of 70% for example. The relationship to changes in daily precipitation that have previously been noted and to changes in the moisture budget over this period are examined.

  20. Shifts in Summertime Precipitation Accumulation Distributions over the US

    NASA Astrophysics Data System (ADS)

    Martinez-Villalobos, C.; Neelin, J. D.

    2017-12-01

    Precipitation accumulations, i.e., the amount of precipitation integrated over the course of an event, is a variable with both important physical and societal implications. Previous observational studies show that accumulation distributions have a characteristic shape, with an approximately power law decrease at first, followed by a sharp decrease at a characteristic large event cutoff scale. This cutoff scale is important as it limits the biggest accumulation events. Stochastic prototypes show that the resulting distributions, and importantly the large event cutoff scale, can be understood as a result of the interplay between moisture loss by precipitation and changes in moisture sinks/sources due to fluctuations in moisture divergence over the course of a precipitation event. The strength of this fluctuating moisture sink/source term is expected to increase under global warming, with both theory and climate model simulations predicting a concomitant increase in the large event cutoff scale. This cutoff scale increase has important consequences as it implies an approximately exponential increase for the largest accumulation events. Given its importance, in this study we characterize and track changes in the distribution of precipitation events accumulations over the contiguous US. Accumulation distributions are calculated using hourly precipitation data from 1700 stations, covering the 1974-2013 period over May-October. The resulting distributions largely follow the aforementioned shape, with individual cutoff scales depending on the local climate. An increase in the large event cutoff scale over this period is observed over several regions over the US, most notably over the eastern third of the US. In agreement with the increase in the cutoff, almost exponential increases in the highest accumulation percentiles occur over these regions, with increases in the 99.9 percentile in the Northeast of 70% for example. The relationship to changes in daily precipitation that have previously been noted and to changes in the moisture budget over this period are examined.

  1. Double inflation - A possible resolution of the large-scale structure problem

    NASA Technical Reports Server (NTRS)

    Turner, Michael S.; Villumsen, Jens V.; Vittorio, Nicola; Silk, Joseph; Juszkiewicz, Roman

    1987-01-01

    A model is presented for the large-scale structure of the universe in which two successive inflationary phases resulted in large small-scale and small large-scale density fluctuations. This bimodal density fluctuation spectrum in an Omega = 1 universe dominated by hot dark matter leads to large-scale structure of the galaxy distribution that is consistent with recent observational results. In particular, large, nearly empty voids and significant large-scale peculiar velocity fields are produced over scales of about 100 Mpc, while the small-scale structure over less than about 10 Mpc resembles that in a low-density universe, as observed. Detailed analytical calculations and numerical simulations are given of the spatial and velocity correlations.

  2. Neighborhood Structural Similarity Mapping for the Classification of Masses in Mammograms.

    PubMed

    Rabidas, Rinku; Midya, Abhishek; Chakraborty, Jayasree

    2018-05-01

    In this paper, two novel feature extraction methods, using neighborhood structural similarity (NSS), are proposed for the characterization of mammographic masses as benign or malignant. Since gray-level distribution of pixels is different in benign and malignant masses, more regular and homogeneous patterns are visible in benign masses compared to malignant masses; the proposed method exploits the similarity between neighboring regions of masses by designing two new features, namely, NSS-I and NSS-II, which capture global similarity at different scales. Complementary to these global features, uniform local binary patterns are computed to enhance the classification efficiency by combining with the proposed features. The performance of the features are evaluated using the images from the mini-mammographic image analysis society (mini-MIAS) and digital database for screening mammography (DDSM) databases, where a tenfold cross-validation technique is incorporated with Fisher linear discriminant analysis, after selecting the optimal set of features using stepwise logistic regression method. The best area under the receiver operating characteristic curve of 0.98 with an accuracy of is achieved with the mini-MIAS database, while the same for the DDSM database is 0.93 with accuracy .

  3. Breast mass segmentation in mammograms combining fuzzy c-means and active contours

    NASA Astrophysics Data System (ADS)

    Hmida, Marwa; Hamrouni, Kamel; Solaiman, Basel; Boussetta, Sana

    2018-04-01

    Segmentation of breast masses in mammograms is a challenging issue due to the nature of mammography and the characteristics of masses. In fact, mammographic images are poor in contrast and breast masses have various shapes and densities with fuzzy and ill-defined borders. In this paper, we propose a method based on a modified Chan-Vese active contour model for mass segmentation in mammograms. We conduct the experiment on mass Regions of Interest (ROI) extracted from the MIAS database. The proposed method consists of mainly three stages: Firstly, the ROI is preprocessed to enhance the contrast. Next, two fuzzy membership maps are generated from the preprocessed ROI based on fuzzy C-Means algorithm. These fuzzy membership maps are finally used to modify the energy of the Chan-Vese model and to perform the final segmentation. Experimental results indicate that the proposed method yields good mass segmentation results.

  4. Automated analysis for microcalcifications in high resolution digital mammograms

    DOEpatents

    Mascio, Laura N.

    1996-01-01

    A method for automatically locating microcalcifications indicating breast cancer. The invention assists mammographers in finding very subtle microcalcifications and in recognizing the pattern formed by all the microcalcifications. It also draws attention to microcalcifications that might be overlooked because a more prominent feature draws attention away from an important object. A new filter has been designed to weed out false positives in one of the steps of the method. Previously, iterative selection threshold was used to separate microcalcifications from the spurious signals resulting from texture or other background. A Selective Erosion or Enhancement (SEE) Filter has been invented to improve this step. Since the algorithm detects areas containing potential calcifications on the mammogram, it can be used to determine which areas need be stored at the highest resolution available, while, in addition, the full mammogram can be reduced to an appropriate resolution for the remaining cancer signs.

  5. Automated analysis for microcalcifications in high resolution digital mammograms

    DOEpatents

    Mascio, L.N.

    1996-12-17

    A method is disclosed for automatically locating microcalcifications indicating breast cancer. The invention assists mammographers in finding very subtle microcalcifications and in recognizing the pattern formed by all the microcalcifications. It also draws attention to microcalcifications that might be overlooked because a more prominent feature draws attention away from an important object. A new filter has been designed to weed out false positives in one of the steps of the method. Previously, iterative selection threshold was used to separate microcalcifications from the spurious signals resulting from texture or other background. A Selective Erosion or Enhancement (SEE) Filter has been invented to improve this step. Since the algorithm detects areas containing potential calcifications on the mammogram, it can be used to determine which areas need be stored at the highest resolution available, while, in addition, the full mammogram can be reduced to an appropriate resolution for the remaining cancer signs. 8 figs.

  6. Quantifying Stock Return Distributions in Financial Markets

    PubMed Central

    Botta, Federico; Moat, Helen Susannah; Stanley, H. Eugene; Preis, Tobias

    2015-01-01

    Being able to quantify the probability of large price changes in stock markets is of crucial importance in understanding financial crises that affect the lives of people worldwide. Large changes in stock market prices can arise abruptly, within a matter of minutes, or develop across much longer time scales. Here, we analyze a dataset comprising the stocks forming the Dow Jones Industrial Average at a second by second resolution in the period from January 2008 to July 2010 in order to quantify the distribution of changes in market prices at a range of time scales. We find that the tails of the distributions of logarithmic price changes, or returns, exhibit power law decays for time scales ranging from 300 seconds to 3600 seconds. For larger time scales, we find that the distributions tails exhibit exponential decay. Our findings may inform the development of models of market behavior across varying time scales. PMID:26327593

  7. Quantifying Stock Return Distributions in Financial Markets.

    PubMed

    Botta, Federico; Moat, Helen Susannah; Stanley, H Eugene; Preis, Tobias

    2015-01-01

    Being able to quantify the probability of large price changes in stock markets is of crucial importance in understanding financial crises that affect the lives of people worldwide. Large changes in stock market prices can arise abruptly, within a matter of minutes, or develop across much longer time scales. Here, we analyze a dataset comprising the stocks forming the Dow Jones Industrial Average at a second by second resolution in the period from January 2008 to July 2010 in order to quantify the distribution of changes in market prices at a range of time scales. We find that the tails of the distributions of logarithmic price changes, or returns, exhibit power law decays for time scales ranging from 300 seconds to 3600 seconds. For larger time scales, we find that the distributions tails exhibit exponential decay. Our findings may inform the development of models of market behavior across varying time scales.

  8. Large-scale velocities and primordial non-Gaussianity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, Fabian

    2010-09-15

    We study the peculiar velocities of density peaks in the presence of primordial non-Gaussianity. Rare, high-density peaks in the initial density field can be identified with tracers such as galaxies and clusters in the evolved matter distribution. The distribution of relative velocities of peaks is derived in the large-scale limit using two different approaches based on a local biasing scheme. Both approaches agree, and show that halos still stream with the dark matter locally as well as statistically, i.e. they do not acquire a velocity bias. Nonetheless, even a moderate degree of (not necessarily local) non-Gaussianity induces a significant skewnessmore » ({approx}0.1-0.2) in the relative velocity distribution, making it a potentially interesting probe of non-Gaussianity on intermediate to large scales. We also study two-point correlations in redshift space. The well-known Kaiser formula is still a good approximation on large scales, if the Gaussian halo bias is replaced with its (scale-dependent) non-Gaussian generalization. However, there are additional terms not encompassed by this simple formula which become relevant on smaller scales (k > or approx. 0.01h/Mpc). Depending on the allowed level of non-Gaussianity, these could be of relevance for future large spectroscopic surveys.« less

  9. Study of the Effects of Total Modulation Transfer Function Changes on Observer Performance Using Clinical Mammograms.

    NASA Astrophysics Data System (ADS)

    Bencomo, Jose Antonio Fagundez

    The main goal of this study was to relate physical changes in image quality measured by Modulation Transfer Function (MTF) to diagnostic accuracy. One Hundred and Fifty Kodak Min-R screen/film combination conventional craniocaudal mammograms obtained with the Pfizer Microfocus Mammographic system were selected from the files of the Department of Radiology, at M.D. Anderson Hospital and Tumor Institute. The mammograms included 88 cases with a variety of benign diagnosis and 62 cases with a variety of malignant biopsy diagnosis. The average age of the patient population was 55 years old. 70 cases presented calcifications with 30 cases having calcifications smaller than 0.5mm. 46 cases presented irregular bordered masses larger than 1 cm. 30 cases presented smooth bordered masses with 20 larger than 1 cm. Four separated copies of the original images were made each having a different change in the MTF using a defocusing technique whereby copies of the original were obtained by light exposure through different thicknesses (spacing) of transparent film base. The mammograms were randomized, and evaluated by three experienced mammographers for the degree of visibility of various anatomical breast structures and pathological lesions (masses and calicifications), subjective image quality, and mammographic interpretation. 3,000 separate evaluations were anayzed by several statistical techniques including Receiver Operating Characteristic curve analysis, McNemar test for differences between proportions and the Landis et al. method of agreement weighted kappa for ordinal categorical data. Results from the statistical analysis show: (1) There were no statistical significant differences in the diagnostic accuracy of the observers when diagnosing from mammograms with the same MTF. (2) There were no statistically significant differences in diagnostic accuracy for each observer when diagnosing from mammograms with the different MTF's used in the study. (3) There statistical significant differences in detail visibility between the copies and the originals. Detail visibility was better in the originals. (4) Feature interpretations were not significantly different between the originals and the copies. (5) Perception of image quality did not affect image interpretation. Continuation and improvement of this research ca be accomplished by: using a case population more sensitive to MTF changes, i.e., asymptomatic women with minimum breast cancer, more observers (including less experienced radiologists and experienced technologists) must collaborate in the study, and using a minimum of 200 benign and 200 malignant cases.

  10. Large-scale motions in the universe: Using clusters of galaxies as tracers

    NASA Technical Reports Server (NTRS)

    Gramann, Mirt; Bahcall, Neta A.; Cen, Renyue; Gott, J. Richard

    1995-01-01

    Can clusters of galaxies be used to trace the large-scale peculiar velocity field of the universe? We answer this question by using large-scale cosmological simulations to compare the motions of rich clusters of galaxies with the motion of the underlying matter distribution. Three models are investigated: Omega = 1 and Omega = 0.3 cold dark matter (CDM), and Omega = 0.3 primeval baryonic isocurvature (PBI) models, all normalized to the Cosmic Background Explorer (COBE) background fluctuations. We compare the cluster and mass distribution of peculiar velocities, bulk motions, velocity dispersions, and Mach numbers as a function of scale for R greater than or = 50/h Mpc. We also present the large-scale velocity and potential maps of clusters and of the matter. We find that clusters of galaxies trace well the large-scale velocity field and can serve as an efficient tool to constrain cosmological models. The recently reported bulk motion of clusters 689 +/- 178 km/s on approximately 150/h Mpc scale (Lauer & Postman 1994) is larger than expected in any of the models studied (less than or = 190 +/- 78 km/s).

  11. Image Based Biomarker of Breast Cancer Risk: Analysis of Risk Disparity Among Minority Populations

    DTIC Science & Technology

    2014-03-01

    attenuation coefficient of calcium hydroxyapatite ; is a parameter controlling the contrast of MCs in synthetic images (0< ə); and is the linear...effect of acquisition parameters and quantum noise," Med Phys, 37, 1591-600 (2010). [13] M. J. Yaffe, J. M. Boone, N. Packard, O. Alonzo-Proulx, S. Y...the acquisition of individual mammograms, the use of linear transformations does not seem appropriate for mammogram registration. Non-linear

  12. Using a Tracking System to Improve Prostate Cancer Screening and Follow-up in a Small Urban Community

    DTIC Science & Technology

    2001-05-01

    clinical practice, attention is directed toward informing the general public about them. In the late 1980 ’s, the Prostate Cancer Education Council...impact of abnormal mammograms on psychosocial outcomes and subsequent screening. PsychoOncology, 9, 402-410. Myers, R.E., Hyslop T., Jennings-Dozier, K...impact of abnormal mammograms on psychosocial outcomes and subsequent screening. PsychoOncology, 9, 402- 410. Myers, R.E., Hyslop T., Jennings-Dozier, K

  13. Diagnosing Diagnosis Errors: Lessons From A Multi-Institutional Collaborative Project

    DTIC Science & Technology

    2005-01-01

    Breast Cancer Inappropriately reassured to have benign lesions - 21/435 (5%); 14 (3%) misread mammogram, 4 (1%) misread pathologic finding, 5 (1...diagnostic tests they are using. It is well known that a normal mammogram in a woman with a breast lump does not rule out the diagnosis of breast cancer ...physician delay in the diagnosis of breast cancer . Arch Intern Med 2002;162:1343–8. 27. Clark S. Spinal infections go undetected. Lancet 1998;351

  14. Development of a Computer-Aided Diagnosis System for Early Detection of Masses Using Retrospectively Detected Cancers on Prior Mammograms

    DTIC Science & Technology

    2006-06-01

    Hadjiiski, and N. Petrick, "Computerized nipple identification for multiple image analysis in computer-aided diagnosis," Medical Physics 31, 2871...candidates, 3 identification of suspicious objects, 4 feature extraction and analysis, and 5 FP reduc- tion by classification of normal tissue...detection of microcalcifi- cations on digitized mammograms.41 An illustration of a La- placian decomposition tree is shown on the left-hand side of Fig. 4

  15. Frequency-Domain Optical Mammogram

    DTIC Science & Technology

    2002-10-01

    have performed the proposed analysis of frequency-domain optical mammograms for a clinical population of about 150 patients. This analysis has led to...model the propagation of light in tissue14-20 have led to new approaches to optical mammography. As The authors are with the Department of Electrical...Modulation Methods, and Signal Detection /406 7.2.1 Lasers and arc lamps / 407’ 7.2.2 Pulsed sources / 407 7.2.3 Laser diodes and light-emitting diodes ( LEDs

  16. Mammography Screening Among African-American Women With a Family History of Breast Cancer

    DTIC Science & Technology

    1999-02-01

    Women into Mammography Stages of C hange ................................................................... Page 101-102 Appendix F: Poster Presentations...Agree 5. Strongly agree 7. Refused 8. Don’t know 2.8 Once you have a couple of mammograms that are normal, you dont need any more for a few years...mammogram is off schedule but is not thinking or planning to get another and has not scheduled an appointment. 102 Appendix F Poster Presentations and

  17. Mammographic features of isolated tuberculous mastitis.

    PubMed

    Al-Marri, Mohammed R; Aref, Essam; Omar, Ahamed J

    2005-04-01

    To present the mammography findings in 8 patients with tuberculosis (TB) of the breast, with a review of the literature. This study is a retrospective data collection. Each chart with confirmed breast TB based on bacteriology or pathologic findings was analyzed for clinical presentation, gender, nationality, demographic data, prior history of TB, investigation, management, mammographic findings and ultrasound, when available. Mammograms were reviewed by 2 consultant radiologists without knowing the previous diagnosis or the nature of the study. The study was carried out at The State Tuberculosis Registry and Radiology Department, Hamad General Hospital, State of Qatar, from 1990 to 2002. Out of 13 females with TB mastitis, only 8 cases had mammograms preoperatively. The incidence of breast TB in Qatar is rare (1/1000 mammograms per year). Three types of TB mastitis were identified in our study; the nodular (50%), the diffuse (37.5%) of which 77% were limited to one sector of the breast and the sclerosing (12.5%) mastitis. Three patients (43%) were reported as carcinoma. Although mammography identified 3 types of TB, it was not helpful in differentiating TB from carcinoma of the breast. However, the careful evaluation of the degree of density and trabecular thickening of the mass in relation to it size might reduce the number of false positive cases of carcinoma diagnosed with mammograms. Biopsy specimen remains the best diagnostic tool in TB mastitis.

  18. U.S. Preventive Services Task Force recommendations and cancer screening among female Medicare beneficiaries.

    PubMed

    Salloum, Ramzi G; Kohler, Racquel E; Jensen, Gail A; Sheridan, Stacey L; Carpenter, William R; Biddle, Andrea K

    2014-03-01

    Medicare covers several cancer screening tests not currently recommended by the U.S. Preventive Services Task Force (Task Force). In September 2002, the Task Force relaxed the upper age limit of 70 years for breast cancer screening recommendations, and in March 2003 an upper age limit of 65 years was introduced for cervical cancer screening recommendations. We assessed whether mammogram and Pap test utilization among women with Medicare coverage is influenced by changes in the Task Force's recommendations for screening. We identified female Medicare beneficiaries aged 66-80 years and used bivariate probit regression to examine the receipt of breast (mammogram) and cervical (Pap test) cancer screening reflecting changes in the Task Force recommendations. We analyzed 9,760 Medicare Current Beneficiary Survey responses from 2001 to 2007. More than two-thirds reported receiving a mammogram and more than one-third a Pap test in the previous 2 years. Lack of recommendation was given as a reason for not getting screened among the majority (51% for mammogram and 75% for Pap). After controlling for beneficiary-level socioeconomic characteristics and access to care factors, we did not observe a significant change in breast and cervical cancer screening patterns following the changes in Task Force recommendations. Although there is evidence that many Medicare beneficiaries adhere to screening guidelines, some women may be receiving non-recommended screening services covered by Medicare.

  19. Pattern Recognition and Size Prediction of Microcalcification Based on Physical Characteristics by Using Digital Mammogram Images.

    PubMed

    Jothilakshmi, G R; Raaza, Arun; Rajendran, V; Sreenivasa Varma, Y; Guru Nirmal Raj, R

    2018-06-05

    Breast cancer is one of the life-threatening cancers occurring in women. In recent years, from the surveys provided by various medical organizations, it has become clear that the mortality rate of females is increasing owing to the late detection of breast cancer. Therefore, an automated algorithm is needed to identify the early occurrence of microcalcification, which would assist radiologists and physicians in reducing the false predictions via image processing techniques. In this work, we propose a new algorithm to detect the pattern of a microcalcification by calculating its physical characteristics. The considered physical characteristics are the reflection coefficient and mass density of the binned digital mammogram image. The calculation of physical characteristics doubly confirms the presence of malignant microcalcification. Subsequently, by interpolating the physical characteristics via thresholding and mapping techniques, a three-dimensional (3D) projection of the region of interest (RoI) is obtained in terms of the distance in millimeter. The size of a microcalcification is determined using this 3D-projected view. This algorithm is verified with 100 abnormal mammogram images showing microcalcification and 10 normal mammogram images. In addition to the size calculation, the proposed algorithm acts as a good classifier that is used to classify the considered input image as normal or abnormal with the help of only two physical characteristics. This proposed algorithm exhibits a classification accuracy of 99%.

  20. Ethnic differences in social support after initial receipt of an abnormal mammogram.

    PubMed

    Molina, Yamile; Hohl, Sarah D; Nguyen, Michelle; Hempstead, Bridgette H; Weatherby, Shauna Rae; Dunbar, Claire; Beresford, Shirley A A; Ceballos, Rachel M

    2016-10-01

    We examine access to and type of social support after initial receipt of an abnormal mammogram across non-Latina White (NLW), African American, and Latina women. This cross-sectional study used a mixed method design, with quantitative and qualitative measures. Women were recruited through 2 community advocates and 3 breast-health-related care organizations. With regard to access, African American women were less likely to access social support relative to NLW counterparts. Similar nonsignificant differences were found for Latinas. Women did not discuss results with family and friends to avoid burdening social networks and negative reactions. Networks' geographic constraints and medical mistrust influenced Latina and African American women's decisions to discuss results. With regard to type of social support, women reported emotional support across ethnicity. Latina and African American women reported more instrumental support, whereas NLW women reported more informational support in the context of their well-being. There are shared and culturally unique aspects of women's experiences with social support after initially receiving an abnormal mammogram. Latina and African American women may particularly benefit from informational support from health care professionals. Communitywide efforts to mitigate mistrust and encourage active communication about cancer may improve ethnic disparities in emotional well-being and diagnostic resolution during initial receipt of an abnormal mammogram. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  1. Mammography use among women ages 40-49 after the 2009 U.S. Preventive Services Task Force recommendation.

    PubMed

    Block, Lauren D; Jarlenski, Marian P; Wu, Albert W; Bennett, Wendy L

    2013-11-01

    In 2009, the U.S. Preventive Service Task Force changed its recommendation regarding screening mammography in average-risk women aged 40-49 years. To evaluate the effects of the 2009 recommendation on reported mammogram use in a population-based survey. Secondary data analysis of data collected in the 2006, 2008, and 2010 Behavioral Risk Factor Surveillance System surveys. Women ages 40-74 years in the 50 states and Washington, DC who were not pregnant at time of survey and reported data on mammogram use during the 2006, 2008, or 2010 survey. Mammogram use was compared between women ages 40-49 and women ages 50-74 before and after the recommendation. We performed a difference-in-difference estimation adjusted for access to care, education, race, and health status, and stratified analyses by whether women reported having a routine checkup in the prior year. Reported prevalence of mammogram use in the past year among women ages 40-49 and 50-74 was 53.2 % and 65.2 %, respectively in 2008, and 51.7 % and 62.4 % in 2010. In 2010, mammography use did not significantly decline from 2006-2008 in women ages 40-49 relative to women ages 50-74. There was no reduction in mammography use among younger women in 2010 compared to older women and previous years. Patients and providers may have been hesitant to comply with the 2009 recommendation.

  2. Family/friend recommendations and mammography intentions: the roles of perceived mammography norms and support.

    PubMed

    Molina, Yamile; Ornelas, India J; Doty, Sarah L; Bishop, Sonia; Beresford, Shirley A A; Coronado, Gloria D

    2015-10-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [-0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  3. Gravitational lenses and large scale structure

    NASA Technical Reports Server (NTRS)

    Turner, Edwin L.

    1987-01-01

    Four possible statistical tests of the large scale distribution of cosmic material are described. Each is based on gravitational lensing effects. The current observational status of these tests is also summarized.

  4. Two-view information fusion for improvement of computer-aided detection (CAD) of breast masses on mammograms

    NASA Astrophysics Data System (ADS)

    Wei, Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Helvie, Mark A.; Roubidoux, Marilyn A.; Zhou, Chuan; Ge, Jun; Zhang, Yiheng

    2006-03-01

    We are developing a two-view information fusion method to improve the performance of our CAD system for mass detection. Mass candidates on each mammogram were first detected with our single-view CAD system. Potential object pairs on the two-view mammograms were then identified by using the distance between the object and the nipple. Morphological features, Hessian feature, correlation coefficients between the two paired objects and texture features were used as input to train a similarity classifier that estimated a similarity scores for each pair. Finally, a linear discriminant analysis (LDA) classifier was used to fuse the score from the single-view CAD system and the similarity score. A data set of 475 patients containing 972 mammograms with 475 biopsy-proven masses was used to train and test the CAD system. All cases contained the CC view and the MLO or LM view. We randomly divided the data set into two independent sets of 243 cases and 232 cases. The training and testing were performed using the 2-fold cross validation method. The detection performance of the CAD system was assessed by free response receiver operating characteristic (FROC) analysis. The average test FROC curve was obtained from averaging the FP rates at the same sensitivity along the two corresponding test FROC curves from the 2-fold cross validation. At the case-based sensitivities of 90%, 85% and 80% on the test set, the single-view CAD system achieved an FP rate of 2.0, 1.5, and 1.2 FPs/image, respectively. With the two-view fusion system, the FP rates were reduced to 1.7, 1.3, and 1.0 FPs/image, respectively, at the corresponding sensitivities. The improvement was found to be statistically significant (p<0.05) by the AFROC method. Our results indicate that the two-view fusion scheme can improve the performance of mass detection on mammograms.

  5. A similarity measure method combining location feature for mammogram retrieval.

    PubMed

    Wang, Zhiqiong; Xin, Junchang; Huang, Yukun; Li, Chen; Xu, Ling; Li, Yang; Zhang, Hao; Gu, Huizi; Qian, Wei

    2018-05-28

    Breast cancer, the most common malignancy among women, has a high mortality rate in clinical practice. Early detection, diagnosis and treatment can reduce the mortalities of breast cancer greatly. The method of mammogram retrieval can help doctors to find the early breast lesions effectively and determine a reasonable feature set for image similarity measure. This will improve the accuracy effectively for mammogram retrieval. This paper proposes a similarity measure method combining location feature for mammogram retrieval. Firstly, the images are pre-processed, the regions of interest are detected and the lesions are segmented in order to get the center point and radius of the lesions. Then, the method, namely Coherent Point Drift, is used for image registration with the pre-defined standard image. The center point and radius of the lesions after registration are obtained and the standard location feature of the image is constructed. This standard location feature can help figure out the location similarity between the image pair from the query image to each dataset image in the database. Next, the content feature of the image is extracted, including the Histogram of Oriented Gradients, the Edge Direction Histogram, the Local Binary Pattern and the Gray Level Histogram, and the image pair content similarity can be calculated using the Earth Mover's Distance. Finally, the location similarity and content similarity are fused to form the image fusion similarity, and the specified number of the most similar images can be returned according to it. In the experiment, 440 mammograms, which are from Chinese women in Northeast China, are used as the database. When fusing 40% lesion location feature similarity and 60% content feature similarity, the results have obvious advantages. At this time, precision is 0.83, recall is 0.76, comprehensive indicator is 0.79, satisfaction is 96.0%, mean is 4.2 and variance is 17.7. The results show that the precision and recall of this method have obvious advantage, compared with the content-based image retrieval.

  6. Enterprise PACS and image distribution.

    PubMed

    Huang, H K

    2003-01-01

    Around the world now, because of the need to improve operation efficiency and better cost effective healthcare, many large-scale healthcare enterprises have been formed. Each of these enterprises groups hospitals, medical centers, and clinics together as one enterprise healthcare network. The management of these enterprises recognizes the importance of using PACS and image distribution as a key technology in cost-effective healthcare delivery in the enterprise level. As a result, many large-scale enterprise level PACS/image distribution pilot studies, full design and implementation, are underway. The purpose of this paper is to provide readers an overall view of the current status of enterprise PACS and image distribution. reviews three large-scale enterprise PACS/image distribution systems in USA, Germany, and South Korean. The concept of enterprise level PACS/image distribution, its characteristics and ingredients are then discussed. Business models for enterprise level implementation available by the private medical imaging and system integration industry are highlighted. One current system under development in designing a healthcare enterprise level chest tuberculosis (TB) screening in Hong Kong is described in detail. Copyright 2002 Elsevier Science Ltd.

  7. On distributed wavefront reconstruction for large-scale adaptive optics systems.

    PubMed

    de Visser, Cornelis C; Brunner, Elisabeth; Verhaegen, Michel

    2016-05-01

    The distributed-spline-based aberration reconstruction (D-SABRE) method is proposed for distributed wavefront reconstruction with applications to large-scale adaptive optics systems. D-SABRE decomposes the wavefront sensor domain into any number of partitions and solves a local wavefront reconstruction problem on each partition using multivariate splines. D-SABRE accuracy is within 1% of a global approach with a speedup that scales quadratically with the number of partitions. The D-SABRE is compared to the distributed cumulative reconstruction (CuRe-D) method in open-loop and closed-loop simulations using the YAO adaptive optics simulation tool. D-SABRE accuracy exceeds CuRe-D for low levels of decomposition, and D-SABRE proved to be more robust to variations in the loop gain.

  8. Silver hake tracks changes in Northwest Atlantic circulation.

    PubMed

    Nye, Janet A; Joyce, Terrence M; Kwon, Young-Oh; Link, Jason S

    2011-08-02

    Recent studies documenting shifts in spatial distribution of many organisms in response to a warming climate highlight the need to understand the mechanisms underlying species distribution at large spatial scales. Here we present one noteworthy example of remote oceanographic processes governing the spatial distribution of adult silver hake, Merluccius bilinearis, a commercially important fish in the Northeast US shelf region. Changes in spatial distribution of silver hake over the last 40 years are highly correlated with the position of the Gulf Stream. These changes in distribution are in direct response to local changes in bottom temperature on the continental shelf that are responding to the same large scale circulation change affecting the Gulf Stream path, namely changes in the Atlantic meridional overturning circulation (AMOC). If the AMOC weakens, as is suggested by global climate models, silver hake distribution will remain in a poleward position, the extent to which could be forecast at both decadal and multidecadal scales.

  9. Improving Cancer Detection and Dose Efficiency in Dedicated Breast Cancer CT

    DTIC Science & Technology

    2011-02-01

    17. A. E. Burgess, F. L. Jacobson, and P. F. Judy , “ Human observer detection experiments with mammograms and power-law noise,” Med. Phys., Vol. 28...Jacobson F L and Judy P F 2001 Human observer detection experiments with mammograms and power-law noise Med. Phys. 28 419–37 Crawford C R and Kak A C 1979...anthropomorphic head phantom was designed for realistically simulating human head [12], it features not only a natural human skeleton but also contrast

  10. Computerized breast cancer analysis system using three stage semi-supervised learning method.

    PubMed

    Sun, Wenqing; Tseng, Tzu-Liang Bill; Zhang, Jianying; Qian, Wei

    2016-10-01

    A large number of labeled medical image data is usually a requirement to train a well-performed computer-aided detection (CAD) system. But the process of data labeling is time consuming, and potential ethical and logistical problems may also present complications. As a result, incorporating unlabeled data into CAD system can be a feasible way to combat these obstacles. In this study we developed a three stage semi-supervised learning (SSL) scheme that combines a small amount of labeled data and larger amount of unlabeled data. The scheme was modified on our existing CAD system using the following three stages: data weighing, feature selection, and newly proposed dividing co-training data labeling algorithm. Global density asymmetry features were incorporated to the feature pool to reduce the false positive rate. Area under the curve (AUC) and accuracy were computed using 10 fold cross validation method to evaluate the performance of our CAD system. The image dataset includes mammograms from 400 women who underwent routine screening examinations, and each pair contains either two cranio-caudal (CC) or two mediolateral-oblique (MLO) view mammograms from the right and the left breasts. From these mammograms 512 regions were extracted and used in this study, and among them 90 regions were treated as labeled while the rest were treated as unlabeled. Using our proposed scheme, the highest AUC observed in our research was 0.841, which included the 90 labeled data and all the unlabeled data. It was 7.4% higher than using labeled data only. With the increasing amount of labeled data, AUC difference between using mixed data and using labeled data only reached its peak when the amount of labeled data was around 60. This study demonstrated that our proposed three stage semi-supervised learning can improve the CAD performance by incorporating unlabeled data. Using unlabeled data is promising in computerized cancer research and may have a significant impact for future CAD system applications. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Analysis of labor productivity using large-scale data of firm's financial statements

    NASA Astrophysics Data System (ADS)

    Ikeda, Y.; Souma, W.; Aoyama, H.; Fujiwara, Y.; Iyetomi, H.

    2010-08-01

    We investigated labor productivity distribution by analyzing large-scale financial statement data consisting of listed and unlisted Japanese firms to clarify the characteristics of the Japanese labor market. Both high and low productivity sides of the labor productivity distribution follows the power-law distribution. Large inequality in the low productivity side was observed only for the manufacturing sectors in Japan fiscal year (JFY) 1999 and observed for both the manufacturing and non-manufacturing sectors in JFY 2002. The decline in the Japanese GDP in JFY 1999 and JFY 2002 were coincided with the large inequality in the low productivity side of the distribution. A lower peak was found for all non-manufacturing sectors. This might be the origin of the low productivity of the non-manufacturing sectors reported in recent economic studies.

  12. Large-Scale Geographic Variation in Distribution and Abundance of Australian Deep-Water Kelp Forests

    PubMed Central

    Marzinelli, Ezequiel M.; Williams, Stefan B.; Babcock, Russell C.; Barrett, Neville S.; Johnson, Craig R.; Jordan, Alan; Kendrick, Gary A.; Pizarro, Oscar R.; Smale, Dan A.; Steinberg, Peter D.

    2015-01-01

    Despite the significance of marine habitat-forming organisms, little is known about their large-scale distribution and abundance in deeper waters, where they are difficult to access. Such information is necessary to develop sound conservation and management strategies. Kelps are main habitat-formers in temperate reefs worldwide; however, these habitats are highly sensitive to environmental change. The kelp Ecklonia radiate is the major habitat-forming organism on subtidal reefs in temperate Australia. Here, we provide large-scale ecological data encompassing the latitudinal distribution along the continent of these kelp forests, which is a necessary first step towards quantitative inferences about the effects of climatic change and other stressors on these valuable habitats. We used the Autonomous Underwater Vehicle (AUV) facility of Australia’s Integrated Marine Observing System (IMOS) to survey 157,000 m2 of seabed, of which ca 13,000 m2 were used to quantify kelp covers at multiple spatial scales (10–100 m to 100–1,000 km) and depths (15–60 m) across several regions ca 2–6° latitude apart along the East and West coast of Australia. We investigated the large-scale geographic variation in distribution and abundance of deep-water kelp (>15 m depth) and their relationships with physical variables. Kelp cover generally increased with latitude despite great variability at smaller spatial scales. Maximum depth of kelp occurrence was 40–50 m. Kelp latitudinal distribution along the continent was most strongly related to water temperature and substratum availability. This extensive survey data, coupled with ongoing AUV missions, will allow for the detection of long-term shifts in the distribution and abundance of habitat-forming kelp and the organisms they support on a continental scale, and provide information necessary for successful implementation and management of conservation reserves. PMID:25693066

  13. A Web-based Distributed Voluntary Computing Platform for Large Scale Hydrological Computations

    NASA Astrophysics Data System (ADS)

    Demir, I.; Agliamzanov, R.

    2014-12-01

    Distributed volunteer computing can enable researchers and scientist to form large parallel computing environments to utilize the computing power of the millions of computers on the Internet, and use them towards running large scale environmental simulations and models to serve the common good of local communities and the world. Recent developments in web technologies and standards allow client-side scripting languages to run at speeds close to native application, and utilize the power of Graphics Processing Units (GPU). Using a client-side scripting language like JavaScript, we have developed an open distributed computing framework that makes it easy for researchers to write their own hydrologic models, and run them on volunteer computers. Users will easily enable their websites for visitors to volunteer sharing their computer resources to contribute running advanced hydrological models and simulations. Using a web-based system allows users to start volunteering their computational resources within seconds without installing any software. The framework distributes the model simulation to thousands of nodes in small spatial and computational sizes. A relational database system is utilized for managing data connections and queue management for the distributed computing nodes. In this paper, we present a web-based distributed volunteer computing platform to enable large scale hydrological simulations and model runs in an open and integrated environment.

  14. Detection of masses in mammogram images using CNN, geostatistic functions and SVM.

    PubMed

    Sampaio, Wener Borges; Diniz, Edgar Moraes; Silva, Aristófanes Corrêa; de Paiva, Anselmo Cardoso; Gattass, Marcelo

    2011-08-01

    Breast cancer occurs with high frequency among the world's population and its effects impact the patients' perception of their own sexuality and their very personal image. This work presents a computational methodology that helps specialists detect breast masses in mammogram images. The first stage of the methodology aims to improve the mammogram image. This stage consists in removing objects outside the breast, reducing noise and highlighting the internal structures of the breast. Next, cellular neural networks are used to segment the regions that might contain masses. These regions have their shapes analyzed through shape descriptors (eccentricity, circularity, density, circular disproportion and circular density) and their textures analyzed through geostatistic functions (Ripley's K function and Moran's and Geary's indexes). Support vector machines are used to classify the candidate regions as masses or non-masses, with sensitivity of 80%, rates of 0.84 false positives per image and 0.2 false negatives per image, and an area under the ROC curve of 0.87. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Self-Report Versus Medical Record for Mammography Screening Among Minority Women.

    PubMed

    Nandy, Karabi; Menon, Usha; Szalacha, Laura A; Park, HanJong; Lee, Jongwon; Lee, Eunice E

    2016-12-01

    Self-report is the most common means of obtaining mammography screening data. The purpose of this study was to assess the accuracy of minority women's self-reported mammography by comparing their self-reported dates of mammograms with those in their medical records from a community-based randomized control trial. We found that out of 192 women, 116 signed the Health Information Portability and Accountability Act form and, among these, 97 had medical records that could be verified (97 / 116 = 83.6%). Ninety-two records matched where both sources confirmed a mammogram; 48 of 92 (52.2%) matched perfectly on self-reported date of mammogram. Complexities in the verification process warrant caution when verifying self-reported mammography screening in minority populations. In spite of some limitations, our findings support the usage of self-reported data on mammography as a validated tool for other researchers investigating mammography screening among minority women who continue to have low screening rates. © The Author(s) 2016.

  16. Bi-model processing for early detection of breast tumor in CAD system

    NASA Astrophysics Data System (ADS)

    Mughal, Bushra; Sharif, Muhammad; Muhammad, Nazeer

    2017-06-01

    Early screening of skeptical masses in mammograms may reduce mortality rate among women. This rate can be further reduced upon developing the computer-aided diagnosis system with decrease in false assumptions in medical informatics. This method highlights the early tumor detection in digitized mammograms. For improving the performance of this system, a novel bi-model processing algorithm is introduced. It divides the region of interest into two parts, the first one is called pre-segmented region (breast parenchyma) and other is the post-segmented region (suspicious region). This system follows the scheme of the preprocessing technique of contrast enhancement that can be utilized to segment and extract the desired feature of the given mammogram. In the next phase, a hybrid feature block is presented to show the effective performance of computer-aided diagnosis. In order to assess the effectiveness of the proposed method, a database provided by the society of mammographic images is tested. Our experimental outcomes on this database exhibit the usefulness and robustness of the proposed method.

  17. Correlates of mammography screening among Hispanic women living in lower Rio Grande Valley farmworker communities.

    PubMed

    Palmer, Richard C; Fernandez, Maria E; Tortolero-Luna, Guillermo; Gonzales, Alicia; Mullen, Patricia Dolan

    2005-08-01

    Factors contributing to the underuse of mammography screening by female Hispanic farmworkers aged 50 years and older in the Lower Rio Grande Valley were determined through home-based, Spanish-language personal interviews (N = 200). Questions covered adherence to screening mammography guidelines (mammogram within 2 years), healthcare access, sociodemographic characteristics, and theoretical constructs related to breast cancer screening in the literature. Multivariate findings indicated that adherent women were 3.6 times more likely to have health insurance. Self-efficacy for obtaining a mammogram and decisional balance were also significantly related to adherence; age, income, and education variables were not associated, perhaps because of restricted variation. Results indicate continuing efforts are needed to ensure that medically underserved migrant farmworker women have access to health care services. In addition, efforts to increase their self-efficacy in obtaining a mammogram and to counter negative attitudes and opinions by stressing the positive prognosis associated with early detection are warranted.

  18. Evaluation of a "loss-framed" minimal intervention to increase mammography utilization among medically un- and under-insured women.

    PubMed

    Abood, Doris A; Coster, Daniel C; Mullis, Ann K; Black, David R

    2002-01-01

    This study was conducted because mammography is under-utilized, even though it is the most effective early detection screening device for breast cancer. A loss-framed telephonic message based on prospect theory was evaluated for the effects on mammography utilization among medically un- and under-insured women living in demographically similar rural counties in Florida. The sample consisted mostly of White women (approximately 89%) 50-64 years old. Experimental group participants received the loss-framed message telephonically and those in the comparison group received the "usual telephone procedure." Logistic regression analyses revealed that women who received the loss-framed message were six times more likely to obtain a mammogram (OR = 6.6, P < 0.0001). The impact of the loss-framed message persisted even after adjustment for initial versus re-screen mammogram effects. This in-reach, loss-framed, minimal intervention seems to have viability and may serve as an alternative or adjunct program for encouraging women to receive mammograms.

  19. Urban women's preferences for learning of their mammogram result: a qualitative study.

    PubMed

    Marcus, Erin N; Drummond, Darlene; Dietz, Noella

    2012-03-01

    Research suggests that communication of mammogram results is flawed for many low-income ethnic minority women. This study conducted four focus groups with low-income inner-city minority women (n = 34). The goals of our project were: (1) to elucidate women's experiences learning of their result; (2) to elicit their preferences as to how this communication could be improved; and (3) to gather information to help inform the development of a new tool for communicating mammogram results. Salient themes included dissatisfaction with result communication; difficulty elucidating the meaning of a typical results notification letter; a preference for direct verbal communication of results and for print materials that included pictures, testimonials, and an action plan including a hotline to call with questions; and a strong interest in advance education about the likelihood of having to return for additional follow up. Video and other programs to inform patients before the test about what happens after may improve patient satisfaction and enhance women's understanding of their personal result and follow up plan.

  20. A multidisciplinary approach to the development of low-cost high-performance lightwave networks

    NASA Technical Reports Server (NTRS)

    Maitan, Jacek; Harwit, Alex

    1991-01-01

    Our research focuses on high-speed distributed systems. We anticipate that our results will allow the fabrication of low-cost networks employing multi-gigabit-per-second data links for space and military applications. The recent development of high-speed low-cost photonic components and new generations of microprocessors creates an opportunity to develop advanced large-scale distributed information systems. These systems currently involve hundreds of thousands of nodes and are made up of components and communications links that may fail during operation. In order to realize these systems, research is needed into technologies that foster adaptability and scaleability. Self-organizing mechanisms are needed to integrate a working fabric of large-scale distributed systems. The challenge is to fuse theory, technology, and development methodologies to construct a cost-effective, efficient, large-scale system.

  1. Online Support: Impact on Anxiety in Women Who Experience an Abnormal Screening Mammogram

    PubMed Central

    Obadina, Eniola T.; Dubenske, Lori L.; McDowell, Helene E.; Atwood, Amy K.; Mayer, Deborah K.; Woods, Ryan W.; Gustafson, David H.; Burnside, Elizabeth S.

    2014-01-01

    OBJECTIVES To determine whether an online support tool can impact anxiety in women experiencing an abnormal mammogram. MATERIALS AND METHODS We developed an online support system using the Comprehensive Health Enhancement Support System (CHESS) designed for women experiencing an abnormal mammogram as a model. Our trial randomized 130 of these women to online support (the intervention group) or to a list of five commonly used Internet sites (the comparison group). Surveys assessed anxiety and breast cancer worry, and patient satisfaction at three important clinical time points: when women were notified of their abnormal mammogram, at the time of diagnostic imaging, and at the time of biopsy (if biopsy was recommended). RESULTS Study participants in the intervention group showed a significant decrease in anxiety at the time of biopsy compared to the comparison group (p=0.017). However, there was no significant difference in anxiety between the intervention group and the comparison group at the time of diagnostic work-up. We discontinued assessment of patient satisfaction after finding that many women had substantial difficulty answering the questions that referenced their physician, because they did not understand who their physician was for this process of care. CONCLUSION The combination of the inability to identify the physician providing care during the mammography work-up and anxiety effects seen only after an interaction with the breast imaging team may indicate that online support only decreases the anxiety of women in concert with direct interpersonal support from the healthcare team. PMID:25193424

  2. Exploring potential use of internet, E-mail, and instant text messaging to promote breast health and mammogram use among immigrant Hispanic women in Los Angeles County.

    PubMed

    Dang, Catherine M; Estrada, Sylvia; Bresee, Catherine; Phillips, Edward H

    2013-10-01

    Breast cancer is now the leading cause of death in Hispanic women (HW). Internet, e-mail, and instant text messaging may be cost-effective in educating HW about breast health and in reducing breast cancer mortality. We surveyed 905 HW women attending a free health fair about their technology use, acculturation, insurance status, mammography use, and breast cancer knowledge. Data were analyzed by t test or χ(2) tests. Mean age was 51.9 ± 14.2 years (range, 18 to 88 years). Ninety-two per cent were foreign-born. Most had completed some high school (39%) or elementary (38%) education. Most (62%) were uninsured. The majority spoke (67%) and read (66%) only Spanish. Only 60 per cent of HW older than 40 years had a recent mammogram. HW older than 40 years who had not had a recent mammogram were younger (mean 54.9 ± 10.8 vs 58 ± 10.4 years) and less likely to have health insurance (25 vs 44%; P < 0.001). Most HW never use the Internet (58%) or e-mail (64%). However, 70 per cent have mobile phones (66% older than 40 years), and 65 per cent use text messaging daily (58% older than 40 years, P = 0.001). In fact, 45 per cent wish to receive a mammogram reminder by text. Text messaging may be an inexpensive way to promote breast health and screening mammography use among uninsured HW.

  3. Does telephone scheduling assistance increase mammography screening adherence?

    PubMed

    Payton, Colleen A; Sarfaty, Mona; Beckett, Shirley; Campos, Carmen; Hilbert, Kathleen

    2015-11-01

    The 2 objectives were: 1) describe the use of a patient navigation process utilized to promote adherence to mammography screening within a primary care practice, and 2) determine the result of the navigation process and estimate the time required to increase mammography screening with this approach in a commercially insured patient population enrolled in a health maintenance organization. An evaluation of a nonrandomized practice improvement intervention. Women eligible for mammography (n = 298) who did not respond to 2 reminder letters were contacted via telephone by a navigator who offered scheduling assistance for mammography screening. The patient navigator scheduled appointments, documented the number of calls, and confirmed completed mammograms in the electronic health record, as well as estimated the time for calls and chart review. Of the 188 participants reached by phone, 112 (59%) scheduled appointments using the patient navigator, 35 (19%) scheduled their own appointments independently prior to the call, and 41 (22%) declined. As a result of the telephone intervention, 78 of the 188 women reached (41%) received a mammogram; also, all 35 women who had independently scheduled a mammogram received one. Chart documentation confirmed that 113 (38%) of the cohort of 298 women completed a mammogram. The estimated time burden for the entire project was 55 hours and 33 minutes, including calling patients, scheduling appointments, and chart review. A patient navigator can increase mammography adherence in a previously nonadherent population by making the screening appointment while the patient is on the phone.

  4. Breast cancers missed by screening radiologists can be detected by reading mammograms at a distance.

    PubMed

    Schreutelkamp, Ineke L; Kwee, Robert M; Veekmans, Peter; Adriaensen, Miraude E A P M

    2018-05-03

    During locally organized quality assurance evaluation sessions for screening radiologists, we noticed that individual screening radiologists did miss tumours which in our opinion could be detected at a distance. To determine whether tumours missed by individual screening radiologists can be detected at a distance. Twenty-eight screening mammograms of 28 females (mean age 63 years, range 49-73) with a pathologically proven malignant tumour missed by individual screening radiologists were mixed with 56 normal screening mammograms of 56 females (mean age 63 years, range 53-74). This test set was independently assessed by a senior screening radiologist and by a radiology resident without prior training in screening mammography at 1.5 m distance from the screen display. Readers were unaware of the prevalence of pathologically proven malignant tumours in the test set. Primary outcome was whether the reader would recall the woman. The senior screening radiologist recalled 28 of 28 women with a pathologically proven malignant tumour (sensitivity of 100%) and 16 of 56 women without pathology (specificity of 71%). The radiology resident recalled 25 of 28 women with a pathologically proven malignant tumour (sensitivity of 89%) and 10 of 56 women without pathology (specificity of 82%). Some malignant tumours missed by an individual screening radiologist can be detected from 1.5 m distance. Therefore, we recommend that screening radiologists consciously take a distant view before closely evaluating the mammogram in detail.

  5. Contrast limited adaptive histogram equalization image processing to improve the detection of simulated spiculations in dense mammograms.

    PubMed

    Pisano, E D; Zong, S; Hemminger, B M; DeLuca, M; Johnston, R E; Muller, K; Braeuning, M P; Pizer, S M

    1998-11-01

    The purpose of this project was to determine whether Contrast Limited Adaptive Histogram Equalization (CLAHE) improves detection of simulated spiculations in dense mammograms. Lines simulating the appearance of spiculations, a common marker of malignancy when visualized with masses, were embedded in dense mammograms digitized at 50 micron pixels, 12 bits deep. Film images with no CLAHE applied were compared to film images with nine different combinations of clip levels and region sizes applied. A simulated spiculation was embedded in a background of dense breast tissue, with the orientation of the spiculation varied. The key variables involved in each trial included the orientation of the spiculation, contrast level of the spiculation and the CLAHE settings applied to the image. Combining the 10 CLAHE conditions, 4 contrast levels and 4 orientations gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 40 backgrounds. Twenty student observers were asked to detect the orientation of the spiculation in the image. There was a statistically significant improvement in detection performance for spiculations with CLAHE over unenhanced images when the region size was set at 32 with a clip level of 2, and when the region size was set at 32 with a clip level of 4. The selected CLAHE settings should be tested in the clinic with digital mammograms to determine whether detection of spiculations associated with masses detected at mammography can be improved.

  6. A novel deep learning-based approach to high accuracy breast density estimation in digital mammography

    NASA Astrophysics Data System (ADS)

    Ahn, Chul Kyun; Heo, Changyong; Jin, Heongmin; Kim, Jong Hyo

    2017-03-01

    Mammographic breast density is a well-established marker for breast cancer risk. However, accurate measurement of dense tissue is a difficult task due to faint contrast and significant variations in background fatty tissue. This study presents a novel method for automated mammographic density estimation based on Convolutional Neural Network (CNN). A total of 397 full-field digital mammograms were selected from Seoul National University Hospital. Among them, 297 mammograms were randomly selected as a training set and the rest 100 mammograms were used for a test set. We designed a CNN architecture suitable to learn the imaging characteristic from a multitudes of sub-images and classify them into dense and fatty tissues. To train the CNN, not only local statistics but also global statistics extracted from an image set were used. The image set was composed of original mammogram and eigen-image which was able to capture the X-ray characteristics in despite of the fact that CNN is well known to effectively extract features on original image. The 100 test images which was not used in training the CNN was used to validate the performance. The correlation coefficient between the breast estimates by the CNN and those by the expert's manual measurement was 0.96. Our study demonstrated the feasibility of incorporating the deep learning technology into radiology practice, especially for breast density estimation. The proposed method has a potential to be used as an automated and quantitative assessment tool for mammographic breast density in routine practice.

  7. Online support: Impact on anxiety in women who experience an abnormal screening mammogram.

    PubMed

    Obadina, Eniola T; Dubenske, Lori L; McDowell, Helene E; Atwood, Amy K; Mayer, Deborah K; Woods, Ryan W; Gustafson, David H; Burnside, Elizabeth S

    2014-12-01

    To determine whether an online support tool can impact anxiety in women experiencing an abnormal mammogram. We developed an online support system using the Comprehensive Health Enhancement Support System (CHESS) designed for women experiencing an abnormal mammogram as a model. Our trial randomized 130 of these women to online support (the intervention group) or to a list of five commonly used Internet sites (the comparison group). Surveys assessed anxiety and breast cancer worry, and patient satisfaction at three important clinical time points: when women were notified of their abnormal mammogram, at the time of diagnostic imaging, and at the time of biopsy (if biopsy was recommended). Study participants in the intervention group showed a significant decrease in anxiety at the time of biopsy compared to the comparison group (p = 0.017). However, there was no significant difference in anxiety between the intervention group and the comparison group at the time of diagnostic work-up. We discontinued assessment of patient satisfaction after finding that many women had substantial difficulty answering the questions that referenced their physician, because they did not understand who their physician was for this process of care. The combination of the inability to identify the physician providing care during the mammography work-up and anxiety effects seen only after an interaction with the breast imaging team may indicate that online support only decreases the anxiety of women in concert with direct interpersonal support from the healthcare team. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Influencing clinicians and healthcare managers: can ROC be more persuasive?

    NASA Astrophysics Data System (ADS)

    Taylor-Phillips, S.; Wallis, M. G.; Duncan, A.; Gale, A. G.

    2010-02-01

    Receiver Operating Characteristic analysis provides a reliable and cost effective performance measurement tool, without using full clinical trials. However, when ROC analysis shows that performance is statistically superior in one condition than another it is difficult to relate this result to effects in practice, or even to determine whether it is clinically significant. In this paper we present two concurrent analyses: using ROC methods alongside single threshold recall rate data, and suggest that reporting both provides complimentary data. Four mammographers read 160 difficult cases (41% malignant) twice, with and without prior mammograms. Lesion location and probability of malignancy was reported for each case and analyzed using JAFROC. Concurrently each participant chose recall or return to screen for each case. JAFROC analysis showed that the presence of prior mammograms improved performance (p<.05). Single threshold data showed a trend towards a 26% increase in the number of false positive recalls without prior mammograms (p=.056). If this trend were present throughout the NHS Breast Screening Programme then discarding prior mammograms would correspond to an increase in recall rate from 4.6% to 5.3%, and 12,414 extra women recalled annually for assessment. Whilst ROC methods account for all possible thresholds of recall and have higher power, providing a single threshold example of false positive, false negative, and recall rates when reporting results could be more influential for clinicians. This paper discusses whether this is a useful additional method of presenting data, or whether it is misleading and inaccurate.

  9. The effects of gray scale image processing on digital mammography interpretation performance.

    PubMed

    Cole, Elodia B; Pisano, Etta D; Zeng, Donglin; Muller, Keith; Aylward, Stephen R; Park, Sungwook; Kuzmiak, Cherie; Koomen, Marcia; Pavic, Dag; Walsh, Ruth; Baker, Jay; Gimenez, Edgardo I; Freimanis, Rita

    2005-05-01

    To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations-manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE-were presented in soft copy display. There were three radiologists per presentation. Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type.

  10. Assessment of mammographic film processor performance in a hospital and mobile screening unit.

    PubMed

    Murray, J G; Dowsett, D J; Laird, O; Ennis, J T

    1992-12-01

    In contrast to the majority of mammographic breast screening programmes, film processing at this centre occurs on site in both hospital and mobile trailer units. Initial (1989) quality control (QC) sensitometric tests revealed a large variation in film processor performance in the mobile unit. The clinical significance of these variations was assessed and acceptance limits for processor performance determined. Abnormal mammograms were used as reference material and copied using high definition 35 mm film over a range of exposure settings. The copies were than matched with QC film density variation from the mobile unit. All films were subsequently ranked for spatial and contrast resolution. Optimal values for processing time of 2 min (equivalent to film transit time 3 min and developer time 46 s) and temperature of 36 degrees C were obtained. The widespread anomaly of reporting film transit time as processing time is highlighted. Use of mammogram copies as a means of measuring the influence of film processor variation is advocated. Careful monitoring of the mobile unit film processor performance has produced stable quality comparable with the hospital based unit. The advantages of on site film processing are outlined. The addition of a sensitometric step wedge to all mammography film stock as a means of assessing image quality is recommended.

  11. The Role of Medical Interpretation on Breast and Cervical Cancer Screening Among Asian American and Pacific Islander Women

    PubMed Central

    Lee, Jessica; Tran, Jacqueline H.; Kagawa-Singer, Marjorie; Foo, Mary Anne; Nguyen, Tu-Uyen N.; Valdez-Dadia, Annalyn; Thomson, Jasmin; Tanjasiri, Sora Park

    2010-01-01

    We examined whether the impact of medical interpretation services was associated with the receipt of a mammogram, clinical breast exam, and Pap smear. We conducted a large cross-sectional study involving four Asian American and Pacific Islander (AAPI) communities with high proportions of individuals with limited English proficiency (LEP). Participants were recruited from community clinics, churches and temples, supermarkets, and other community gathering sites in Northern and Southern California. Among those that responded, 98% completed the survey rendering a total of 1,708 AAPI women. In a series of multivariate logistic regression models, it was found that women who typically used a medical interpreter had a greater odds of having received a mammogram (odds ratio [OR] = 1.85; 95% confidence interval [CI] = 1.21, 2.83), clinical breast exam (OR = 3.03; 95% CI = 1.82, 5.03), and a Pap smear (OR = 2.34; 95% CI = 1.38, 3.97) than those who did not usually use an interpreter. The study provides support for increasing language access in healthcare settings. In particular, medical interpreters may help increase the utilization of breast and cervical cancer screening among LEP AAPI women. PMID:20352398

  12. The professional quality criteria of Italian breast screening radiologists: results from a national survey comparing the programmes started in 2000-2012 versus the ones started in 1990-1999.

    PubMed

    Morrone, Doralba; Giordano, Livia; Artuso, Franca; Bernardi, Daniela; Fedato, Chiara; Frigerio, Alfonso; Giorgi, Daniela; Naldoni, Carlo; Saguatti, Gianni; Severi, Daniela; Taffurelli, Mario; Terribile, Daniela; Ventura, Leonardo; Bucchi, Lauro

    2017-01-01

    In Italy, due to increasing healthcare budget and staff shortages, the recently created regional mammography screening programmes were established under worse radiology practice quality criteria than the previously created programmes. Using available data from a national questionnaire survey conducted at the end of 2013 and involving 222 responder radiologists, we compared the main professional quality standards of radiologists working in the screening programmes established during the period 2000-2012 with those working in the screening programmes created from 1990 to 1999. The former reported more years of clinical experience in breast imaging and a greater clinical mammogram reading volume than the latter. Conversely, they dedicated less working time to breast imaging, were less likely to participate in the diagnostic assessment of screen-detected lesions, to work in large-staffed screening centres, and to have a screening and a total mammogram reading volume (SMRV and TMRV) ≥ 5000 per year. The level of most professional quality criteria of Italian mammography screening radiologists has decreased over time. As SMRV and TMRV are important predictors of diagnostic accuracy, we can expect a lower interpretation performance of radiologists working in the recently created screening programmes.

  13. Correlating the ground truth of mammographic histology with the success or failure of imaging.

    PubMed

    Tot, Tibor

    2005-02-01

    Detailed and systematic mammographic-pathologic correlation is essential for evaluation of the advantages and disadvantages of mammography as an imaging method as well as for establishing the role of additional methods or alternatives. Two- and three-dimensional large section histopathology represents an ideal tool for this correlation. This kind of interdisciplinary approach ("mammographic histology") is slowly but irrevocably becoming accepted as the new golden standard in diagnosing breast abnormalities. In this review, upon summarizing the theoretical background and our practical experience in routine diagnostic use of these advantageous techniques, we report on the accuracy of the preoperative radiological diagnosis. As compared to the final diagnostic outcome, stellate lesions on the mammogram and microcalcifications of casting type indicate malignancy with very high accuracy while predicting malignancy in cases of powdery and crushed stone type microcalcifications is problematic. The extent of the disease is regularly underestimated on the mammogram by the radiologist. Combining different radiological signs, and comparing repeated static images taken in regular intervals in screening or postoperative follow-up, the mammographer may type and grade the lesions properly in a considerable number of cases. Regular mammographic-pathologic correlation may increase the specificity and sensitivity of mammographic diagnosis. This correlation is essential for establishing the proper pre- and postoperative histological diagnosis, too.

  14. Landscape-scale distribution and density of raptor populations wintering in anthropogenic-dominated desert landscapes

    Treesearch

    Adam E. Duerr; Tricia A. Miller; Kerri L. Cornell Duerr; Michael J. Lanzone; Amy Fesnock; Todd E. Katzner

    2015-01-01

    Anthropogenic development has great potential to affect fragile desert environments. Large-scale development of renewable energy infrastructure is planned for many desert ecosystems. Development plans should account for anthropogenic effects to distributions and abundance of rare or sensitive wildlife; however, baseline data on abundance and distribution of such...

  15. Large Scale Density Estimation of Blue and Fin Whales (LSD)

    DTIC Science & Technology

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Large Scale Density Estimation of Blue and Fin Whales ...sensors, or both. The goal of this research is to develop and implement a new method for estimating blue and fin whale density that is effective over...develop and implement a density estimation methodology for quantifying blue and fin whale abundance from passive acoustic data recorded on sparse

  16. Optical interconnect for large-scale systems

    NASA Astrophysics Data System (ADS)

    Dress, William

    2013-02-01

    This paper presents a switchless, optical interconnect module that serves as a node in a network of identical distribution modules for large-scale systems. Thousands to millions of hosts or endpoints may be interconnected by a network of such modules, avoiding the need for multi-level switches. Several common network topologies are reviewed and their scaling properties assessed. The concept of message-flow routing is discussed in conjunction with the unique properties enabled by the optical distribution module where it is shown how top-down software control (global routing tables, spanning-tree algorithms) may be avoided.

  17. Tail-scope: Using friends to estimate heavy tails of degree distributions in large-scale complex networks

    NASA Astrophysics Data System (ADS)

    Eom, Young-Ho; Jo, Hang-Hyun

    2015-05-01

    Many complex networks in natural and social phenomena have often been characterized by heavy-tailed degree distributions. However, due to rapidly growing size of network data and concerns on privacy issues about using these data, it becomes more difficult to analyze complete data sets. Thus, it is crucial to devise effective and efficient estimation methods for heavy tails of degree distributions in large-scale networks only using local information of a small fraction of sampled nodes. Here we propose a tail-scope method based on local observational bias of the friendship paradox. We show that the tail-scope method outperforms the uniform node sampling for estimating heavy tails of degree distributions, while the opposite tendency is observed in the range of small degrees. In order to take advantages of both sampling methods, we devise the hybrid method that successfully recovers the whole range of degree distributions. Our tail-scope method shows how structural heterogeneities of large-scale complex networks can be used to effectively reveal the network structure only with limited local information.

  18. Network placement optimization for large-scale distributed system

    NASA Astrophysics Data System (ADS)

    Ren, Yu; Liu, Fangfang; Fu, Yunxia; Zhou, Zheng

    2018-01-01

    The network geometry strongly influences the performance of the distributed system, i.e., the coverage capability, measurement accuracy and overall cost. Therefore the network placement optimization represents an urgent issue in the distributed measurement, even in large-scale metrology. This paper presents an effective computer-assisted network placement optimization procedure for the large-scale distributed system and illustrates it with the example of the multi-tracker system. To get an optimal placement, the coverage capability and the coordinate uncertainty of the network are quantified. Then a placement optimization objective function is developed in terms of coverage capabilities, measurement accuracy and overall cost. And a novel grid-based encoding approach for Genetic algorithm is proposed. So the network placement is optimized by a global rough search and a local detailed search. Its obvious advantage is that there is no need for a specific initial placement. At last, a specific application illustrates this placement optimization procedure can simulate the measurement results of a specific network and design the optimal placement efficiently.

  19. The topology of large-scale structure. I - Topology and the random phase hypothesis. [galactic formation models

    NASA Technical Reports Server (NTRS)

    Weinberg, David H.; Gott, J. Richard, III; Melott, Adrian L.

    1987-01-01

    Many models for the formation of galaxies and large-scale structure assume a spectrum of random phase (Gaussian), small-amplitude density fluctuations as initial conditions. In such scenarios, the topology of the galaxy distribution on large scales relates directly to the topology of the initial density fluctuations. Here a quantitative measure of topology - the genus of contours in a smoothed density distribution - is described and applied to numerical simulations of galaxy clustering, to a variety of three-dimensional toy models, and to a volume-limited sample of the CfA redshift survey. For random phase distributions the genus of density contours exhibits a universal dependence on threshold density. The clustering simulations show that a smoothing length of 2-3 times the mass correlation length is sufficient to recover the topology of the initial fluctuations from the evolved galaxy distribution. Cold dark matter and white noise models retain a random phase topology at shorter smoothing lengths, but massive neutrino models develop a cellular topology.

  20. States of mind: Emotions, body feelings, and thoughts share distributed neural networks

    PubMed Central

    Oosterwijk, Suzanne; Lindquist, Kristen A.; Anderson, Eric; Dautoff, Rebecca; Moriguchi, Yoshiya; Barrett, Lisa Feldman

    2012-01-01

    Scientists have traditionally assumed that different kinds of mental states (e.g., fear, disgust, love, memory, planning, concentration, etc.) correspond to different psychological faculties that have domain-specific correlates in the brain. Yet, growing evidence points to the constructionist hypothesis that mental states emerge from the combination of domain-general psychological processes that map to large-scale distributed brain networks. In this paper, we report a novel study testing a constructionist model of the mind in which participants generated three kinds of mental states (emotions, body feelings, or thoughts) while we measured activity within large-scale distributed brain networks using fMRI. We examined the similarity and differences in the pattern of network activity across these three classes of mental states. Consistent with a constructionist hypothesis, a combination of large-scale distributed networks contributed to emotions, thoughts, and body feelings, although these mental states differed in the relative contribution of those networks. Implications for a constructionist functional architecture of diverse mental states are discussed. PMID:22677148

  1. Selectivity by host plants affects the distribution of arbuscular mycorrhizal fungi: evidence from ITS rDNA sequence metadata.

    PubMed

    Yang, Haishui; Zang, Yanyan; Yuan, Yongge; Tang, Jianjun; Chen, Xin

    2012-04-12

    Arbuscular mycorrhizal fungi (AMF) can form obligate symbioses with the vast majority of land plants, and AMF distribution patterns have received increasing attention from researchers. At the local scale, the distribution of AMF is well documented. Studies at large scales, however, are limited because intensive sampling is difficult. Here, we used ITS rDNA sequence metadata obtained from public databases to study the distribution of AMF at continental and global scales. We also used these sequence metadata to investigate whether host plant is the main factor that affects the distribution of AMF at large scales. We defined 305 ITS virtual taxa (ITS-VTs) among all sequences of the Glomeromycota by using a comprehensive maximum likelihood phylogenetic analysis. Each host taxonomic order averaged about 53% specific ITS-VTs, and approximately 60% of the ITS-VTs were host specific. Those ITS-VTs with wide host range showed wide geographic distribution. Most ITS-VTs occurred in only one type of host functional group. The distributions of most ITS-VTs were limited across ecosystem, across continent, across biogeographical realm, and across climatic zone. Non-metric multidimensional scaling analysis (NMDS) showed that AMF community composition differed among functional groups of hosts, and among ecosystem, continent, biogeographical realm, and climatic zone. The Mantel test showed that AMF community composition was significantly correlated with plant community composition among ecosystem, among continent, among biogeographical realm, and among climatic zone. The structural equation modeling (SEM) showed that the effects of ecosystem, continent, biogeographical realm, and climatic zone were mainly indirect on AMF distribution, but plant had strongly direct effects on AMF. The distribution of AMF as indicated by ITS rDNA sequences showed a pattern of high endemism at large scales. This pattern indicates high specificity of AMF for host at different scales (plant taxonomic order and functional group) and high selectivity from host plants for AMF. The effects of ecosystemic, biogeographical, continental and climatic factors on AMF distribution might be mediated by host plants.

  2. Large-scale runoff generation - parsimonious parameterisation using high-resolution topography

    NASA Astrophysics Data System (ADS)

    Gong, L.; Halldin, S.; Xu, C.-Y.

    2011-08-01

    World water resources have primarily been analysed by global-scale hydrological models in the last decades. Runoff generation in many of these models are based on process formulations developed at catchments scales. The division between slow runoff (baseflow) and fast runoff is primarily governed by slope and spatial distribution of effective water storage capacity, both acting at very small scales. Many hydrological models, e.g. VIC, account for the spatial storage variability in terms of statistical distributions; such models are generally proven to perform well. The statistical approaches, however, use the same runoff-generation parameters everywhere in a basin. The TOPMODEL concept, on the other hand, links the effective maximum storage capacity with real-world topography. Recent availability of global high-quality, high-resolution topographic data makes TOPMODEL attractive as a basis for a physically-based runoff-generation algorithm at large scales, even if its assumptions are not valid in flat terrain or for deep groundwater systems. We present a new runoff-generation algorithm for large-scale hydrology based on TOPMODEL concepts intended to overcome these problems. The TRG (topography-derived runoff generation) algorithm relaxes the TOPMODEL equilibrium assumption so baseflow generation is not tied to topography. TRG only uses the topographic index to distribute average storage to each topographic index class. The maximum storage capacity is proportional to the range of topographic index and is scaled by one parameter. The distribution of storage capacity within large-scale grid cells is obtained numerically through topographic analysis. The new topography-derived distribution function is then inserted into a runoff-generation framework similar VIC's. Different basin parts are parameterised by different storage capacities, and different shapes of the storage-distribution curves depend on their topographic characteristics. The TRG algorithm is driven by the HydroSHEDS dataset with a resolution of 3" (around 90 m at the equator). The TRG algorithm was validated against the VIC algorithm in a common model framework in 3 river basins in different climates. The TRG algorithm performed equally well or marginally better than the VIC algorithm with one less parameter to be calibrated. The TRG algorithm also lacked equifinality problems and offered a realistic spatial pattern for runoff generation and evaporation.

  3. Large-scale runoff generation - parsimonious parameterisation using high-resolution topography

    NASA Astrophysics Data System (ADS)

    Gong, L.; Halldin, S.; Xu, C.-Y.

    2010-09-01

    World water resources have primarily been analysed by global-scale hydrological models in the last decades. Runoff generation in many of these models are based on process formulations developed at catchments scales. The division between slow runoff (baseflow) and fast runoff is primarily governed by slope and spatial distribution of effective water storage capacity, both acting a very small scales. Many hydrological models, e.g. VIC, account for the spatial storage variability in terms of statistical distributions; such models are generally proven to perform well. The statistical approaches, however, use the same runoff-generation parameters everywhere in a basin. The TOPMODEL concept, on the other hand, links the effective maximum storage capacity with real-world topography. Recent availability of global high-quality, high-resolution topographic data makes TOPMODEL attractive as a basis for a physically-based runoff-generation algorithm at large scales, even if its assumptions are not valid in flat terrain or for deep groundwater systems. We present a new runoff-generation algorithm for large-scale hydrology based on TOPMODEL concepts intended to overcome these problems. The TRG (topography-derived runoff generation) algorithm relaxes the TOPMODEL equilibrium assumption so baseflow generation is not tied to topography. TGR only uses the topographic index to distribute average storage to each topographic index class. The maximum storage capacity is proportional to the range of topographic index and is scaled by one parameter. The distribution of storage capacity within large-scale grid cells is obtained numerically through topographic analysis. The new topography-derived distribution function is then inserted into a runoff-generation framework similar VIC's. Different basin parts are parameterised by different storage capacities, and different shapes of the storage-distribution curves depend on their topographic characteristics. The TRG algorithm is driven by the HydroSHEDS dataset with a resolution of 3'' (around 90 m at the equator). The TRG algorithm was validated against the VIC algorithm in a common model framework in 3 river basins in different climates. The TRG algorithm performed equally well or marginally better than the VIC algorithm with one less parameter to be calibrated. The TRG algorithm also lacked equifinality problems and offered a realistic spatial pattern for runoff generation and evaporation.

  4. Distributed intrusion detection system based on grid security model

    NASA Astrophysics Data System (ADS)

    Su, Jie; Liu, Yahui

    2008-03-01

    Grid computing has developed rapidly with the development of network technology and it can solve the problem of large-scale complex computing by sharing large-scale computing resource. In grid environment, we can realize a distributed and load balance intrusion detection system. This paper first discusses the security mechanism in grid computing and the function of PKI/CA in the grid security system, then gives the application of grid computing character in the distributed intrusion detection system (IDS) based on Artificial Immune System. Finally, it gives a distributed intrusion detection system based on grid security system that can reduce the processing delay and assure the detection rates.

  5. MHD Modeling of the Solar Wind with Turbulence Transport and Heating

    NASA Technical Reports Server (NTRS)

    Goldstein, M. L.; Usmanov, A. V.; Matthaeus, W. H.; Breech, B.

    2009-01-01

    We have developed a magnetohydrodynamic model that describes the global axisymmetric steady-state structure of the solar wind near solar minimum with account for transport of small-scale turbulence associated heating. The Reynolds-averaged mass, momentum, induction, and energy equations for the large-scale solar wind flow are solved simultaneously with the turbulence transport equations in the region from 0.3 to 100 AU. The large-scale equations include subgrid-scale terms due to turbulence and the turbulence (small-scale) equations describe the effects of transport and (phenomenologically) dissipation of the MHD turbulence based on a few statistical parameters (turbulence energy, normalized cross-helicity, and correlation scale). The coupled set of equations is integrated numerically for a source dipole field on the Sun by a time-relaxation method in the corotating frame of reference. We present results on the plasma, magnetic field, and turbulence distributions throughout the heliosphere and on the role of the turbulence in the large-scale structure and temperature distribution in the solar wind.

  6. Information Power Grid Posters

    NASA Technical Reports Server (NTRS)

    Vaziri, Arsi

    2003-01-01

    This document is a summary of the accomplishments of the Information Power Grid (IPG). Grids are an emerging technology that provide seamless and uniform access to the geographically dispersed, computational, data storage, networking, instruments, and software resources needed for solving large-scale scientific and engineering problems. The goal of the NASA IPG is to use NASA's remotely located computing and data system resources to build distributed systems that can address problems that are too large or complex for a single site. The accomplishments outlined in this poster presentation are: access to distributed data, IPG heterogeneous computing, integration of large-scale computing node into distributed environment, remote access to high data rate instruments,and exploratory grid environment.

  7. Groups of galaxies in the Center for Astrophysics redshift survey

    NASA Technical Reports Server (NTRS)

    Ramella, Massimo; Geller, Margaret J.; Huchra, John P.

    1989-01-01

    By applying the Huchra and Geller (1982) objective group identification algorithm to the Center for Astrophysics' redshift survey, a catalog of 128 groups with three or more members is extracted, and 92 of these are used as a statistical sample. A comparison of the distribution of group centers with the distribution of all galaxies in the survey indicates qualitatively that groups trace the large-scale structure of the region. The physical properties of groups may be related to the details of large-scale structure, and it is concluded that differences among group catalogs may be due to the properties of large-scale structures and their location relative to the survey limits.

  8. Development of a Computer-aided Diagnosis System for Early Detection of Masses Using Retrospectively Detected Cancers on Prior Mammograms

    DTIC Science & Technology

    2009-06-01

    131 cases with 131 biopsy proven masses, of which 27 were malignant and 104 benign. The true locations of the masses were identified by an experi- enced ...two acquisitions would cause differ- ences in the subtlety of the masses on the FFDMs and SFMs. However, assuming that the differences are ran- dom... Lado , M. Souto, and J. J. Vidal, “Computer-aided diagnosis: Automatic detection of malignant masses in digitized mammograms,” Med. Phys. 25, 957–964

  9. Building a Better Model: A Personalized Breast Cancer Risk Model Incorporating Breast Density to Stratify Risk and Improve Application of Resources

    DTIC Science & Technology

    2013-10-01

    MAMMOGRAM 5 OTHER BREAST IMAGING TEST (E.G., MRI , ULTRASOUND) 6 THEMOGRAPHY 7 NOTHING 8 DK/REF PROBE: ANYTHING ELSE? IF NECESSARY: JUST THE...SKIP IF HOWCHECK = 5] Have you ever had any other breast imaging procedure designed to detect breast cancer (for example, an MRI or ultrasound? 1 YES...SELECT ALL THAT APPLY) 1 Another mammogram 2 Ultrasound of the breast 3 MRI of the breast 4 OTHER [specify:] 31 5 NONE 6 DK/REF {Q: ADDSURG

  10. Anomaly detection for medical images based on a one-class classification

    NASA Astrophysics Data System (ADS)

    Wei, Qi; Ren, Yinhao; Hou, Rui; Shi, Bibo; Lo, Joseph Y.; Carin, Lawrence

    2018-02-01

    Detecting an anomaly such as a malignant tumor or a nodule from medical images including mammogram, CT or PET images is still an ongoing research problem drawing a lot of attention with applications in medical diagnosis. A conventional way to address this is to learn a discriminative model using training datasets of negative and positive samples. The learned model can be used to classify a testing sample into a positive or negative class. However, in medical applications, the high unbalance between negative and positive samples poses a difficulty for learning algorithms, as they will be biased towards the majority group, i.e., the negative one. To address this imbalanced data issue as well as leverage the huge amount of negative samples, i.e., normal medical images, we propose to learn an unsupervised model to characterize the negative class. To make the learned model more flexible and extendable for medical images of different scales, we have designed an autoencoder based on a deep neural network to characterize the negative patches decomposed from large medical images. A testing image is decomposed into patches and then fed into the learned autoencoder to reconstruct these patches themselves. The reconstruction error of one patch is used to classify this patch into a binary class, i.e., a positive or a negative one, leading to a one-class classifier. The positive patches highlight the suspicious areas containing anomalies in a large medical image. The proposed method has been tested on InBreast dataset and achieves an AUC of 0.84. The main contribution of our work can be summarized as follows. 1) The proposed one-class learning requires only data from one class, i.e., the negative data; 2) The patch-based learning makes the proposed method scalable to images of different sizes and helps avoid the large scale problem for medical images; 3) The training of the proposed deep convolutional neural network (DCNN) based auto-encoder is fast and stable.

  11. Mapping the universe in three dimensions

    PubMed Central

    Haynes, Martha P.

    1996-01-01

    The determination of the three-dimensional layout of galaxies is critical to our understanding of the evolution of galaxies and the structures in which they lie, to our determination of the fundamental parameters of cosmology, and to our understanding of both the past and future histories of the universe at large. The mapping of the large scale structure in the universe via the determination of galaxy red shifts (Doppler shifts) is a rapidly growing industry thanks to technological developments in detectors and spectrometers at radio and optical wavelengths. First-order application of the red shift-distance relation (Hubble’s law) allows the analysis of the large-scale distribution of galaxies on scales of hundreds of megaparsecs. Locally, the large-scale structure is very complex but the overall topology is not yet clear. Comparison of the observed red shifts with ones expected on the basis of other distance estimates allows mapping of the gravitational field and the underlying total density distribution. The next decade holds great promise for our understanding of the character of large-scale structure and its origin. PMID:11607714

  12. Mapping the universe in three dimensions.

    PubMed

    Haynes, M P

    1996-12-10

    The determination of the three-dimensional layout of galaxies is critical to our understanding of the evolution of galaxies and the structures in which they lie, to our determination of the fundamental parameters of cosmology, and to our understanding of both the past and future histories of the universe at large. The mapping of the large scale structure in the universe via the determination of galaxy red shifts (Doppler shifts) is a rapidly growing industry thanks to technological developments in detectors and spectrometers at radio and optical wavelengths. First-order application of the red shift-distance relation (Hubble's law) allows the analysis of the large-scale distribution of galaxies on scales of hundreds of megaparsecs. Locally, the large-scale structure is very complex but the overall topology is not yet clear. Comparison of the observed red shifts with ones expected on the basis of other distance estimates allows mapping of the gravitational field and the underlying total density distribution. The next decade holds great promise for our understanding of the character of large-scale structure and its origin.

  13. Validating Bayesian truth serum in large-scale online human experiments.

    PubMed

    Frank, Morgan R; Cebrian, Manuel; Pickard, Galen; Rahwan, Iyad

    2017-01-01

    Bayesian truth serum (BTS) is an exciting new method for improving honesty and information quality in multiple-choice survey, but, despite the method's mathematical reliance on large sample sizes, existing literature about BTS only focuses on small experiments. Combined with the prevalence of online survey platforms, such as Amazon's Mechanical Turk, which facilitate surveys with hundreds or thousands of participants, BTS must be effective in large-scale experiments for BTS to become a readily accepted tool in real-world applications. We demonstrate that BTS quantifiably improves honesty in large-scale online surveys where the "honest" distribution of answers is known in expectation on aggregate. Furthermore, we explore a marketing application where "honest" answers cannot be known, but find that BTS treatment impacts the resulting distributions of answers.

  14. Validating Bayesian truth serum in large-scale online human experiments

    PubMed Central

    Frank, Morgan R.; Cebrian, Manuel; Pickard, Galen; Rahwan, Iyad

    2017-01-01

    Bayesian truth serum (BTS) is an exciting new method for improving honesty and information quality in multiple-choice survey, but, despite the method’s mathematical reliance on large sample sizes, existing literature about BTS only focuses on small experiments. Combined with the prevalence of online survey platforms, such as Amazon’s Mechanical Turk, which facilitate surveys with hundreds or thousands of participants, BTS must be effective in large-scale experiments for BTS to become a readily accepted tool in real-world applications. We demonstrate that BTS quantifiably improves honesty in large-scale online surveys where the “honest” distribution of answers is known in expectation on aggregate. Furthermore, we explore a marketing application where “honest” answers cannot be known, but find that BTS treatment impacts the resulting distributions of answers. PMID:28494000

  15. Scale-dependent coupling of hysteretic capillary pressure, trapping, and fluid mobilities

    NASA Astrophysics Data System (ADS)

    Doster, F.; Celia, M. A.; Nordbotten, J. M.

    2012-12-01

    Many applications of multiphase flow in porous media, including CO2-storage and enhanced oil recovery, require mathematical models that span a large range of length scales. In the context of numerical simulations, practical grid sizes are often on the order of tens of meters, thereby de facto defining a coarse model scale. Under particular conditions, it is possible to approximate the sub-grid-scale distribution of the fluid saturation within a grid cell; that reconstructed saturation can then be used to compute effective properties at the coarse scale. If both the density difference between the fluids and the vertical extend of the grid cell are large, and buoyant segregation within the cell on a sufficiently shorte time scale, then the phase pressure distributions are essentially hydrostatic and the saturation profile can be reconstructed from the inferred capillary pressures. However, the saturation reconstruction may not be unique because the parameters and parameter functions of classical formulations of two-phase flow in porous media - the relative permeability functions, the capillary pressure -saturation relationship, and the residual saturations - show path dependence, i.e. their values depend not only on the state variables but also on their drainage and imbibition histories. In this study we focus on capillary pressure hysteresis and trapping and show that the contribution of hysteresis to effective quantities is dependent on the vertical length scale. By studying the transition from the two extreme cases - the homogeneous saturation distribution for small vertical extents and the completely segregated distribution for large extents - we identify how hysteretic capillary pressure at the local scale induces hysteresis in all coarse-scale quantities for medium vertical extents and finally vanishes for large vertical extents. Our results allow for more accurate vertically integrated modeling while improving our understanding of the coupling of capillary pressure and relative permeabilities over larger length scales.

  16. Mammography in females with an implanted medical device: impact on image quality, pain and anxiety.

    PubMed

    Paap, Ellen; Witjes, Marloes; van Landsveld-Verhoeven, Cary; Pijnappel, Ruud M; Maas, Angela H E M; Broeders, Mireille J M

    2016-10-01

    To assess the image quality of mammograms in females with an implanted medical device (IMD), to evaluate pain and anxiety during mammography in these females and to investigate the experience of radiographers. Image quality was evaluated by two radiographers and one radiologist in the images of females with an IMD participating in the Dutch screening programme (clients). Pain and anxiety were scored using a Numeric Rating Scale in both clients visiting a screening organization and patients from the Isala Hospital, Zwolle. Experience of screening radiographers was collected with a questionnaire. Images of the breast with IMD showed reduced contrast in craniocaudal (CC) and mediolateral-oblique (MLO) views [by both the radiographers and radiologist (range: 11-29%)], less projected breast tissue [only radiographers; CC lateral side: 25.5%, 95% confidence interval (CI): 18.7-32.2] and reduced projection of the pectoral muscle (only radiographers; MLO width pectoral muscle: 31.5%, 95% CI: 24.4-38.7). Clients experienced more pain and anxiety during mammography in the breast with IMD compared to the breast without IMD in the breast (pain difference CC: 0.48 ± 0.16, p = 0.003; pain difference MLO: 0.46 ± 0.16, p = 0.004; anxiety difference 1.30 ± 0.22; p < 0.001). Patients experienced more pain (1.05 ± 0.12; p < 0.001) and anxiety (1.22 ± 0.15; p < 0.001) after placement of IMD. Radiographers are more cautious, more anxious and use less compression during mammography of breasts with IMD. Image quality in a breast with an IMD could be improved by projecting more breast tissue on the mammogram, thereby including (part of) the IMD between the paddles, if required. In addition, radiographers should pay sufficient attention to reducing discomfort both before and during the screening examination. Little is known about the quality of mammography in females with an IMD or how these females and radiographers experience the screening examination. The results of our study showed that having an IMD could result in a suboptimal mammogram and increased discomfort.

  17. Large-Scale Ichthyoplankton and Water Mass Distribution along the South Brazil Shelf

    PubMed Central

    de Macedo-Soares, Luis Carlos Pinto; Garcia, Carlos Alberto Eiras; Freire, Andrea Santarosa; Muelbert, José Henrique

    2014-01-01

    Ichthyoplankton is an essential component of pelagic ecosystems, and environmental factors play an important role in determining its distribution. We have investigated simultaneous latitudinal and cross-shelf gradients in ichthyoplankton abundance to test the hypothesis that the large-scale distribution of fish larvae in the South Brazil Shelf is associated with water mass composition. Vertical plankton tows were collected between 21°27′ and 34°51′S at 107 stations, in austral late spring and early summer seasons. Samples were taken with a conical-cylindrical plankton net from the depth of chlorophyll maxima to the surface in deep stations, or from 10 m from the bottom to the surface in shallow waters. Salinity and temperature were obtained with a CTD/rosette system, which provided seawater for chlorophyll-a and nutrient concentrations. The influence of water mass on larval fish species was studied using Indicator Species Analysis, whereas environmental effects on the distribution of larval fish species were analyzed by Distance-based Redundancy Analysis. Larval fish species were associated with specific water masses: in the north, Sardinella brasiliensis was found in Shelf Water; whereas in the south, Engraulis anchoita inhabited the Plata Plume Water. At the slope, Tropical Water was characterized by the bristlemouth Cyclothone acclinidens. The concurrent analysis showed the importance of both cross-shelf and latitudinal gradients on the large-scale distribution of larval fish species. Our findings reveal that ichthyoplankton composition and large-scale spatial distribution are determined by water mass composition in both latitudinal and cross-shelf gradients. PMID:24614798

  18. Large-scale ichthyoplankton and water mass distribution along the South Brazil Shelf.

    PubMed

    de Macedo-Soares, Luis Carlos Pinto; Garcia, Carlos Alberto Eiras; Freire, Andrea Santarosa; Muelbert, José Henrique

    2014-01-01

    Ichthyoplankton is an essential component of pelagic ecosystems, and environmental factors play an important role in determining its distribution. We have investigated simultaneous latitudinal and cross-shelf gradients in ichthyoplankton abundance to test the hypothesis that the large-scale distribution of fish larvae in the South Brazil Shelf is associated with water mass composition. Vertical plankton tows were collected between 21°27' and 34°51'S at 107 stations, in austral late spring and early summer seasons. Samples were taken with a conical-cylindrical plankton net from the depth of chlorophyll maxima to the surface in deep stations, or from 10 m from the bottom to the surface in shallow waters. Salinity and temperature were obtained with a CTD/rosette system, which provided seawater for chlorophyll-a and nutrient concentrations. The influence of water mass on larval fish species was studied using Indicator Species Analysis, whereas environmental effects on the distribution of larval fish species were analyzed by Distance-based Redundancy Analysis. Larval fish species were associated with specific water masses: in the north, Sardinella brasiliensis was found in Shelf Water; whereas in the south, Engraulis anchoita inhabited the Plata Plume Water. At the slope, Tropical Water was characterized by the bristlemouth Cyclothone acclinidens. The concurrent analysis showed the importance of both cross-shelf and latitudinal gradients on the large-scale distribution of larval fish species. Our findings reveal that ichthyoplankton composition and large-scale spatial distribution are determined by water mass composition in both latitudinal and cross-shelf gradients.

  19. NASA's Information Power Grid: Large Scale Distributed Computing and Data Management

    NASA Technical Reports Server (NTRS)

    Johnston, William E.; Vaziri, Arsi; Hinke, Tom; Tanner, Leigh Ann; Feiereisen, William J.; Thigpen, William; Tang, Harry (Technical Monitor)

    2001-01-01

    Large-scale science and engineering are done through the interaction of people, heterogeneous computing resources, information systems, and instruments, all of which are geographically and organizationally dispersed. The overall motivation for Grids is to facilitate the routine interactions of these resources in order to support large-scale science and engineering. Multi-disciplinary simulations provide a good example of a class of applications that are very likely to require aggregation of widely distributed computing, data, and intellectual resources. Such simulations - e.g. whole system aircraft simulation and whole system living cell simulation - require integrating applications and data that are developed by different teams of researchers frequently in different locations. The research team's are the only ones that have the expertise to maintain and improve the simulation code and/or the body of experimental data that drives the simulations. This results in an inherently distributed computing and data management environment.

  20. Comparisons of ionospheric electron density distributions reconstructed by GPS computerized tomography, backscatter ionograms, and vertical ionograms

    NASA Astrophysics Data System (ADS)

    Zhou, Chen; Lei, Yong; Li, Bofeng; An, Jiachun; Zhu, Peng; Jiang, Chunhua; Zhao, Zhengyu; Zhang, Yuannong; Ni, Binbin; Wang, Zemin; Zhou, Xuhua

    2015-12-01

    Global Positioning System (GPS) computerized ionosphere tomography (CIT) and ionospheric sky wave ground backscatter radar are both capable of measuring the large-scale, two-dimensional (2-D) distributions of ionospheric electron density (IED). Here we report the spatial and temporal electron density results obtained by GPS CIT and backscatter ionogram (BSI) inversion for three individual experiments. Both the GPS CIT and BSI inversion techniques demonstrate the capability and the consistency of reconstructing large-scale IED distributions. To validate the results, electron density profiles obtained from GPS CIT and BSI inversion are quantitatively compared to the vertical ionosonde data, which clearly manifests that both methods output accurate information of ionopsheric electron density and thereby provide reliable approaches to ionospheric soundings. Our study can improve current understanding of the capability and insufficiency of these two methods on the large-scale IED reconstruction.

  1. Efficient On-Demand Operations in Large-Scale Infrastructures

    ERIC Educational Resources Information Center

    Ko, Steven Y.

    2009-01-01

    In large-scale distributed infrastructures such as clouds, Grids, peer-to-peer systems, and wide-area testbeds, users and administrators typically desire to perform "on-demand operations" that deal with the most up-to-date state of the infrastructure. However, the scale and dynamism present in the operating environment make it challenging to…

  2. Backscattering from a Gaussian distributed, perfectly conducting, rough surface

    NASA Technical Reports Server (NTRS)

    Brown, G. S.

    1977-01-01

    The problem of scattering by random surfaces possessing many scales of roughness is analyzed. The approach is applicable to bistatic scattering from dielectric surfaces, however, this specific analysis is restricted to backscattering from a perfectly conducting surface in order to more clearly illustrate the method. The surface is assumed to be Gaussian distributed so that the surface height can be split into large and small scale components, relative to the electromagnetic wavelength. A first order perturbation approach is employed wherein the scattering solution for the large scale structure is perturbed by the small scale diffraction effects. The scattering from the large scale structure is treated via geometrical optics techniques. The effect of the large scale surface structure is shown to be equivalent to a convolution in k-space of the height spectrum with the following: the shadowing function, a polarization and surface slope dependent function, and a Gaussian factor resulting from the unperturbed geometrical optics solution. This solution provides a continuous transition between the near normal incidence geometrical optics and wide angle Bragg scattering results.

  3. Biology-Inspired Distributed Consensus in Massively-Deployed Sensor Networks

    NASA Technical Reports Server (NTRS)

    Jones, Kennie H.; Lodding, Kenneth N.; Olariu, Stephan; Wilson, Larry; Xin, Chunsheng

    2005-01-01

    Promises of ubiquitous control of the physical environment by large-scale wireless sensor networks open avenues for new applications that are expected to redefine the way we live and work. Most of recent research has concentrated on developing techniques for performing relatively simple tasks in small-scale sensor networks assuming some form of centralized control. The main contribution of this work is to propose a new way of looking at large-scale sensor networks, motivated by lessons learned from the way biological ecosystems are organized. Indeed, we believe that techniques used in small-scale sensor networks are not likely to scale to large networks; that such large-scale networks must be viewed as an ecosystem in which the sensors/effectors are organisms whose autonomous actions, based on local information, combine in a communal way to produce global results. As an example of a useful function, we demonstrate that fully distributed consensus can be attained in a scalable fashion in massively deployed sensor networks where individual motes operate based on local information, making local decisions that are aggregated across the network to achieve globally-meaningful effects.

  4. A qualitative study on Singaporean women's views towards breast cancer screening and Single Nucleotide Polymorphisms (SNPs) gene testing to guide personalised screening strategies.

    PubMed

    Wong, Xin Yi; Chong, Kok Joon; van Til, Janine A; Wee, Hwee Lin

    2017-11-21

    Breast cancer is the top cancer by incidence and mortality in Singaporean women. Mammography is by far its best screening tool, but current recommended age and interval may not yield the most benefit. Recent studies have demonstrated the potential of single nucleotide polymorphisms (SNPs) to improve discriminatory accuracy of breast cancer risk assessment models. This study was conducted to understand Singaporean women's views towards breast cancer screening and SNPs gene testing to guide personalised screening strategies. Focus group discussions were conducted among English-speaking women (n = 27) between 40 to 65 years old, both current and lapsed mammogram users. Women were divided into four groups based on age and mammogram usage. Discussions about breast cancer and screening experience, as well as perception and attitude towards SNPs gene testing were conducted by an experienced moderator. Women were also asked for factors that will influence their uptake of the test. Transcripts were analysed using thematic analysis to captured similarities and differences in views expressed. Barriers to repeat mammogram attendance include laziness to make appointment and painful and uncomfortable screening process. However, the underlying reason may be low perceived susceptibility to breast cancer. Facilitators to repeat mammogram attendance include ease of making appointment and timely reminders. Women were generally receptive towards SNPs gene testing, but required information on accuracy, cost, invasiveness, and side effects before they decide whether to go for it. Other factors include waiting time for results and frequency interval. On average, women gave a rating of 7.5 (range 5 to 10) when asked how likely they will go for the test. Addressing concerns such as pain and discomfort during mammogram, providing timely reminders and debunking breast cancer myths can help to improve screening uptake. Women demonstrated a spectrum of responses towards a novel test like SNPs gene testing, but need more information to make an informed decision. Future public health education on predictive genetic testing should adequately address both benefits and risks. Findings from this study is used to inform a discrete choice experiment to empirically quantify women preferences and willingness-to-pay for SNPs gene testing.

  5. Dissemination of periodic mammography and patterns of use, by birth cohort, in Catalonia (Spain)

    PubMed Central

    Rue, Montserrat; Carles, Misericordia; Vilaprinyo, Ester; Martinez-Alonso, Montserrat; Espinas, Josep-Alfons; Pla, Roger; Brugulat, Pilar

    2008-01-01

    Background In Catalonia (Spain) breast cancer mortality has declined since the beginning of the 1990s. The dissemination of early detection by mammography and the introduction of adjuvant treatments are among the possible causes of this decrease, and both were almost coincident in time. Thus, understanding how these procedures were incorporated into use in the general population and in women diagnosed with breast cancer is very important for assessing their contribution to the reduction in breast cancer mortality. In this work we have modeled the dissemination of periodic mammography and described repeat mammography behavior in Catalonia from 1975 to 2006. Methods Cross-sectional data from three Catalan Health Surveys for the calendar years 1994, 2002 and 2006 was used. The dissemination of mammography by birth cohort was modeled using a mixed effects model and repeat mammography behavior was described by age and survey year. Results For women born from 1938 to 1952, mammography clearly had a period effect, meaning that they started to have periodic mammograms at the same calendar years but at different ages. The age at which approximately 50% of the women were receiving periodic mammograms went from 57.8 years of age for women born in 1938–1942 to 37.3 years of age for women born in 1963–1967. Women in all age groups experienced an increase in periodic mammography use over time, although women in the 50–69 age group have experienced the highest increase. Currently, the target population of the Catalan Breast Cancer Screening Program, 50–69 years of age, is the group that self-reports the highest utilization of periodic mammograms, followed by the 40–49 age group. A higher proportion of women of all age groups have annual mammograms rather than biennial or irregular ones. Conclusion Mammography in Catalonia became more widely implemented during the 1990s. We estimated when cohorts initiated periodic mammograms and how frequently women are receiving them. These two pieces of information will be entered into a cost-effectiveness model of early detection in Catalonia. PMID:19014679

  6. Anomalies in the GRBs' distribution

    NASA Astrophysics Data System (ADS)

    Bagoly, Zsolt; Horvath, Istvan; Hakkila, Jon; Toth, Viktor

    2015-08-01

    Gamma-ray bursts (GRBs) are the most luminous objects known: they outshine their host galaxies making them ideal candidates for probing large-scale structure. Earlier, the angular distribution of different GRBs (long, intermediate and short) has been studied in detail with different methods and it has been found that the short and intermediate groups showed deviation from the full randomness at different levels (e.g. Vavrek, R., et al. 2008). However these result based only angular measurements of the BATSE experiment, without any spatial distance indicator involved.Currently we have more than 361 GRBs with measured precise position, optical afterglow and redshift, mainly due to the observations of the Swift mission. This sample is getting large enough that it its homogeneous and isotropic distribution a large scale can be checked. We have recently (Horvath, I. et al., 2014) identified a large clustering of gamma-ray bursts at redshift z ~ 2 in the general direction of the constellations of Hercules and Corona Borealis. This angular excess cannot be entirely attributed to known selection biases, making its existence due to chance unlikely. The scale on which the clustering occurs is disturbingly large, about 2-3 Gpc: the underlying distribution of matter suggested by this cluster is big enough to question standard assumptions about Universal homogeneity and isotropy.

  7. Mass dependence of Higgs boson production at large transverse momentum through a bottom-quark loop

    NASA Astrophysics Data System (ADS)

    Braaten, Eric; Zhang, Hong; Zhang, Jia-Wei

    2018-05-01

    In the production of the Higgs through a bottom-quark loop, the transverse momentum distribution of the Higgs at large PT is complicated by its dependence on two other important scales: the bottom quark mass mb and the Higgs mass mH. A strategy for simplifying the calculation of the cross section at large PT is to calculate only the leading terms in its expansion in mb2/PT2. In this paper, we consider the bottom-quark-loop contribution to the parton process q q ¯→H +g at leading order in αs. We show that the leading power of 1 /PT2 can be expressed in the form of a factorization formula that separates the large scale PT from the scale of the masses. All the dependence on mb and mH can be factorized into a distribution amplitude for b b ¯ in the Higgs, a distribution amplitude for b b ¯ in a real gluon, and an end point contribution. The factorization formula can be used to organize the calculation of the leading terms in the expansion in mb2/PT2 so that every calculation involves at most two scales.

  8. Postmenopausal hormone therapy and changes in mammographic density.

    PubMed

    van Duijnhoven, Fränzel J B; Peeters, Petra H M; Warren, Ruth M L; Bingham, Sheila A; van Noord, Paulus A H; Monninkhof, Evelyn M; Grobbee, Diederick E; van Gils, Carla H

    2007-04-10

    Hormone therapy (HT) use has been associated with an increased breast cancer risk. We explored the underlying mechanism further by determining the effects of HT on mammographic density, a measure of dense tissue in the breast and a consistent breast cancer risk factor. A total of 620 HT users and 620 never users from the Dutch Prospect-European Prospective Investigation into Cancer and Nutrition (EPIC) cohort and 175 HT users and 161 never users from the United Kingdom EPIC-Norfolk cohort were included. For HT users, one mammogram before and one mammogram during HT use was included. For never users, mammograms with similar time intervals were included. Mammographic density was assessed using a computer-assisted method. Changes in density were analyzed using linear regression. The median time between mammograms was 3.0 years and the median duration of HT use was 1 year. The absolute mean decline in percent density was larger in never users (7.3%) than in estrogen therapy users (6.4%; P = .22) and combined HT users (3.5%; P < .01). The effect of HT appeared to be high in a small number of women, whereas most women were unaffected. Our results suggest that HT use, and especially estrogen and progestin use, slows the changes from dense patterns to more fatty patterns that are normally seen in women with increasing age. Given that it is postulated that lifetime cumulative exposure to high density may be related to breast cancer risk, a delay in density decline in HT users potentially could explain their increased breast cancer risk.

  9. Exploring a new bilateral focal density asymmetry based image marker to predict breast cancer risk

    NASA Astrophysics Data System (ADS)

    Aghaei, Faranak; Mirniaharikandehei, Seyedehnafiseh; Hollingsworth, Alan B.; Wang, Yunzhi; Qiu, Yuchen; Liu, Hong; Zheng, Bin

    2017-03-01

    Although breast density has been widely considered an important breast cancer risk factor, it is not very effective to predict risk of developing breast cancer in a short-term or harboring cancer in mammograms. Based on our recent studies to build short-term breast cancer risk stratification models based on bilateral mammographic density asymmetry, we in this study explored a new quantitative image marker based on bilateral focal density asymmetry to predict the risk of harboring cancers in mammograms. For this purpose, we assembled a testing dataset involving 100 positive and 100 negative cases. In each of positive case, no any solid masses are visible on mammograms. We developed a computer-aided detection (CAD) scheme to automatically detect focal dense regions depicting on two bilateral mammograms of left and right breasts. CAD selects one focal dense region with the maximum size on each image and computes its asymmetrical ratio. We used this focal density asymmetry as a new imaging marker to divide testing cases into two groups of higher and lower focal density asymmetry. The first group included 70 cases in which 62.9% are positive, while the second group included 130 cases in which 43.1% are positive. The odds ratio is 2.24. As a result, this preliminary study supported the feasibility of applying a new focal density asymmetry based imaging marker to predict the risk of having mammography-occult cancers. The goal is to assist radiologists more effectively and accurately detect early subtle cancers using mammography and/or other adjunctive imaging modalities in the future.

  10. Visual adaptation and the amplitude spectra of radiological images.

    PubMed

    Kompaniez-Dunigan, Elysse; Abbey, Craig K; Boone, John M; Webster, Michael A

    2018-01-01

    We examined how visual sensitivity and perception are affected by adaptation to the characteristic amplitude spectra of X-ray mammography images. Because of the transmissive nature of X-ray photons, these images have relatively more low-frequency variability than natural images, a difference that is captured by a steeper slope of the amplitude spectrum (~ - 1.5) compared to the ~ 1/f (slope of - 1) spectra common to natural scenes. Radiologists inspecting these images are therefore exposed to a different balance of spectral components, and we measured how this exposure might alter spatial vision. Observers (who were not radiologists) were adapted to images of normal mammograms or the same images sharpened by filtering the amplitude spectra to shallower slopes. Prior adaptation to the original mammograms significantly biased judgments of image focus relative to the sharpened images, demonstrating that the images are sufficient to induce substantial after-effects. The adaptation also induced strong losses in threshold contrast sensitivity that were selective for lower spatial frequencies, though these losses were very similar to the threshold changes induced by the sharpened images. Visual search for targets (Gaussian blobs) added to the images was also not differentially affected by adaptation to the original or sharper images. These results complement our previous studies examining how observers adapt to the textural properties or phase spectra of mammograms. Like the phase spectrum, adaptation to the amplitude spectrum of mammograms alters spatial sensitivity and visual judgments about the images. However, unlike the phase spectrum, adaptation to the amplitude spectra did not confer a selective performance advantage relative to more natural spectra.

  11. Increasing cancer detection yield of breast MRI using a new CAD scheme of mammograms

    NASA Astrophysics Data System (ADS)

    Tan, Maxine; Aghaei, Faranak; Hollingsworth, Alan B.; Stough, Rebecca G.; Liu, Hong; Zheng, Bin

    2016-03-01

    Although breast MRI is the most sensitive imaging modality to detect early breast cancer, its cancer detection yield in breast cancer screening is quite low (< 3 to 4% even for the small group of high-risk women) to date. The purpose of this preliminary study is to test the potential of developing and applying a new computer-aided detection (CAD) scheme of digital mammograms to identify women at high risk of harboring mammography-occult breast cancers, which can be detected by breast MRI. For this purpose, we retrospectively assembled a dataset involving 30 women who had both mammography and breast MRI screening examinations. All mammograms were interpreted as negative, while 5 cancers were detected using breast MRI. We developed a CAD scheme of mammograms, which include a new quantitative mammographic image feature analysis based risk model, to stratify women into two groups with high and low risk of harboring mammography-occult cancer. Among 30 women, 9 were classified into the high risk group by CAD scheme, which included all 5 women who had cancer detected by breast MRI. All 21 low risk women remained negative on the breast MRI examinations. The cancer detection yield of breast MRI applying to this dataset substantially increased from 16.7% (5/30) to 55.6% (5/9), while eliminating 84% (21/25) unnecessary breast MRI screenings. The study demonstrated the potential of applying a new CAD scheme to significantly increase cancer detection yield of breast MRI, while simultaneously reducing the number of negative MRIs in breast cancer screening.

  12. [Opinion and Participation in the Regional Early Breast Cancer Detection Program in 2007 on the part of family physicians from a health district in the Autonomous Community of Madrid, Spain].

    PubMed

    Garrido Elustondo, Sofía; Sánchez Padilla, Elisabeth; Ramírez Alesón, Victoria; González Hernández, Ma José; González Navarro, Andrés; López Gómez, Carlos

    2008-01-01

    Mammogram screening is the most effective method for the early detection of breast cancer. The objective of this study is to evaluate the degree of knowledge, the opinion and the participation in the early breast cancer detection program on the part of the family physicians of the Autonomous Community of Madrid. The population studied was comprised of family physicians from Madrid Health District Seven. An anonymous, self-administered questionnaire comprised of 30 questions grouped into physicians characteristics and opinion concerning the early breast cancer detection programs. A total of 46% of the physicians replied. A total of 94% of the physicians believed that it is their duty to inform their patients concerning preventive activities, including breast cancer screening, and 95% believed their advice to be useful for convincing women to have a mammogram. A total of 72% believed information to be lacking on this program. During the time when mammograms are being taken at their centres, 24% of the physicians surveyed always or almost always ask the women if they have any doubts or would like further information, 43% having set up appointments for them and 95% advising them to have a mammogram taken. The family physicians have a good opinion of the early breast cancer detection program and feel their advice to be effective for improving the participation in the program. They report lack of information and inform women about the program to only a small degree.

  13. Mammographic screening practices among Chinese-Australian women.

    PubMed

    Kwok, Cannas; Fethney, Judith; White, Kate

    2012-03-01

    To report mammographic screening practice among Chinese-Australian women, and to examine the relationship between demographic characteristics, acculturation factors (English proficiency and length of stay in Australia), cultural beliefs, and having a mammogram as recommended. Cross-sectional and descriptive. The study was conducted in 2009 in Sydney, Australia. Of 988 Chinese-Australian women over 18 years of age invited to participate in the study, 785 (79%) completed and returned the questionnaire. Of these women, 320 (40.8%) were in the target age range of 50 to 69 years. The Chinese Breast Cancer Screening Beliefs Questionnaire (CBCSB) was used as a data collection instrument. Analysis included descriptive statistics, bivariate analysis using chi-square and t tests, and logistic regression. Of the 320 women in the targeted age range of 50 to 69 years, 238 (74.4%) had a mammogram as recommended biannually. Being married-de facto, in the 60 to 69 age group, and speaking Cantonese at home were positively associated with women's mammographic screening practice. However, no statistically significant differences in acculturation factors and having a mammogram as recommended were found. In terms of CBCSB score, women who had mammograms as recommended had more positive attitudes toward health checkups and perceived fewer barriers to mammographic screening. Effort should be focused on specific subgroups of Chinese-Australian women in order to fully understand the barriers involved in participating in mammographic screening. Nurses can use the findings from the present study to design culturally sensitive breast cancer screening programs to encourage women's participation in mammography. © 2011 Sigma Theta Tau International.

  14. Use of the Persuasive Health Message framework in the development of a community-based mammography promotion campaign

    PubMed Central

    Johnson-Turbes, Ashani

    2015-01-01

    Purpose We describe how the Persuasive Health Message (PHM) framework was used to guide the formative evaluation informing development of messages and materials used in a community-based multi-media campaign intended to motivate low-income African American women to obtain low- or no-cost mammograms through the CDC’s National Breast and Cervical Cancer Early Detection Program. Methods Seventy-eight African American women were recruited for eight focus groups that discussed breast cancer screening. The moderator guide was developed in accordance with the PHM framework and solicited information on perceived threat and efficacy, cues, salient beliefs and referents, and barriers to self-efficacy. Results We created persuasive messages to emphasize that African American women are susceptible to the threat of breast cancer, but that their personal action in obtaining regular mammograms may lead to early detection, subsequent treatment, and reduced cancer mortality. The messages addressed concerns of self-efficacy by emphasizing that uninsured women can also obtain high-quality low- or no-cost mammograms. In an attempt to combat the sentiment that breast cancer is a death sentence, the messages indicated that breast cancer can be successfully treated, especially when detected early. Conclusions The PHM framework consists of three steps: (1) determine information about threat and efficacy; (2) develop an audience profile; and (3) construct a persuasive message. It offered our team easy-to-follow, flexible steps to create a persuasive and effective campaign promoting awareness and use of mammogram screening among low-income African American women. PMID:25724414

  15. FROM FINANCE TO COSMOLOGY: THE COPULA OF LARGE-SCALE STRUCTURE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scherrer, Robert J.; Berlind, Andreas A.; Mao, Qingqing

    2010-01-01

    Any multivariate distribution can be uniquely decomposed into marginal (one-point) distributions, and a function called the copula, which contains all of the information on correlations between the distributions. The copula provides an important new methodology for analyzing the density field in large-scale structure. We derive the empirical two-point copula for the evolved dark matter density field. We find that this empirical copula is well approximated by a Gaussian copula. We consider the possibility that the full n-point copula is also Gaussian and describe some of the consequences of this hypothesis. Future directions for investigation are discussed.

  16. Conditional sampling technique to test the applicability of the Taylor hypothesis for the large-scale coherent structures

    NASA Technical Reports Server (NTRS)

    Hussain, A. K. M. F.

    1980-01-01

    Comparisons of the distributions of large scale structures in turbulent flow with distributions based on time dependent signals from stationary probes and the Taylor hypothesis are presented. The study investigated an area in the near field of a 7.62 cm circular air jet at a Re of 32,000, specifically having coherent structures through small-amplitude controlled excitation and stable vortex pairing in the jet column mode. Hot-wire and X-wire anemometry were employed to establish phase averaged spatial distributions of longitudinal and lateral velocities, coherent Reynolds stress and vorticity, background turbulent intensities, streamlines and pseudo-stream functions. The Taylor hypothesis was used to calculate spatial distributions of the phase-averaged properties, with results indicating that the usage of the local time-average velocity or streamwise velocity produces large distortions.

  17. Mammogram classification scheme using 2D-discrete wavelet and local binary pattern for detection of breast cancer

    NASA Astrophysics Data System (ADS)

    Adi Putra, Januar

    2018-04-01

    In this paper, we propose a new mammogram classification scheme to classify the breast tissues as normal or abnormal. Feature matrix is generated using Local Binary Pattern to all the detailed coefficients from 2D-DWT of the region of interest (ROI) of a mammogram. Feature selection is done by selecting the relevant features that affect the classification. Feature selection is used to reduce the dimensionality of data and features that are not relevant, in this paper the F-test and Ttest will be performed to the results of the feature extraction dataset to reduce and select the relevant feature. The best features are used in a Neural Network classifier for classification. In this research we use MIAS and DDSM database. In addition to the suggested scheme, the competent schemes are also simulated for comparative analysis. It is observed that the proposed scheme has a better say with respect to accuracy, specificity and sensitivity. Based on experiments, the performance of the proposed scheme can produce high accuracy that is 92.71%, while the lowest accuracy obtained is 77.08%.

  18. Effectiveness of breast cancer screening policies in countries with medium-low incidence rates.

    PubMed

    Kong, Qingxia; Mondschein, Susana; Pereira, Ana

    2018-02-05

    Chile has lower breast cancer incidence rates compared to those in developed countries. Our public health system aims to perform 10 biennial screening mammograms in the age group of 50 to 69 years by 2020. Using a dynamic programming model, we have found the optimal ages to perform 10 screening mammograms that lead to the lowest lifetime death rate and we have evaluated a set of fixed inter-screening interval policies. The optimal ages for the 10 mammograms are 43, 47, 51, 54, 57, 61, 65, 68, 72, and 76 years, and the most effective fixed inter-screening is every four years after the 40 years. Both policies respectively reduce lifetime death rate in 6.4% and 5.7% and the cost of saving one life in 17% and 9.3% compared to the 2020 Chilean policy. Our findings show that two-year inter-screening interval policies are less effective in countries with lower breast cancer incidence; thus we recommend screening policies with a wider age range and larger inter-screening intervals for Chile.

  19. Effectiveness of breast cancer screening policies in countries with medium-low incidence rates

    PubMed Central

    Kong, Qingxia; Mondschein, Susana; Pereira, Ana

    2018-01-01

    ABSTRACT Chile has lower breast cancer incidence rates compared to those in developed countries. Our public health system aims to perform 10 biennial screening mammograms in the age group of 50 to 69 years by 2020. Using a dynamic programming model, we have found the optimal ages to perform 10 screening mammograms that lead to the lowest lifetime death rate and we have evaluated a set of fixed inter-screening interval policies. The optimal ages for the 10 mammograms are 43, 47, 51, 54, 57, 61, 65, 68, 72, and 76 years, and the most effective fixed inter-screening is every four years after the 40 years. Both policies respectively reduce lifetime death rate in 6.4% and 5.7% and the cost of saving one life in 17% and 9.3% compared to the 2020 Chilean policy. Our findings show that two-year inter-screening interval policies are less effective in countries with lower breast cancer incidence; thus we recommend screening policies with a wider age range and larger inter-screening intervals for Chile. PMID:29412375

  20. The mammography screening employee inreach program.

    PubMed

    Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria

    2007-02-01

    To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.

  1. Classification of breast tissue in mammograms using efficient coding.

    PubMed

    Costa, Daniel D; Campos, Lúcio F; Barros, Allan K

    2011-06-24

    Female breast cancer is the major cause of death by cancer in western countries. Efforts in Computer Vision have been made in order to improve the diagnostic accuracy by radiologists. Some methods of lesion diagnosis in mammogram images were developed based in the technique of principal component analysis which has been used in efficient coding of signals and 2D Gabor wavelets used for computer vision applications and modeling biological vision. In this work, we present a methodology that uses efficient coding along with linear discriminant analysis to distinguish between mass and non-mass from 5090 region of interest from mammograms. The results show that the best rates of success reached with Gabor wavelets and principal component analysis were 85.28% and 87.28%, respectively. In comparison, the model of efficient coding presented here reached up to 90.07%. Altogether, the results presented demonstrate that independent component analysis performed successfully the efficient coding in order to discriminate mass from non-mass tissues. In addition, we have observed that LDA with ICA bases showed high predictive performance for some datasets and thus provide significant support for a more detailed clinical investigation.

  2. Large-Scale Cooperative Task Distribution on Peer-to-Peer Networks

    DTIC Science & Technology

    2012-01-01

    SUBTITLE Large-scale cooperative task distribution on peer-to-peer networks 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...of agents, and each agent attempts to form a coalition with its most profitable partner. The second algorithm builds upon the Shapley for- mula [37...ters at the second layer. These Category Layer clusters each represent a single resource, and agents join one or more clusters based on their

  3. Time-sliced perturbation theory for large scale structure I: general formalism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blas, Diego; Garny, Mathias; Sibiryakov, Sergey

    2016-07-01

    We present a new analytic approach to describe large scale structure formation in the mildly non-linear regime. The central object of the method is the time-dependent probability distribution function generating correlators of the cosmological observables at a given moment of time. Expanding the distribution function around the Gaussian weight we formulate a perturbative technique to calculate non-linear corrections to cosmological correlators, similar to the diagrammatic expansion in a three-dimensional Euclidean quantum field theory, with time playing the role of an external parameter. For the physically relevant case of cold dark matter in an Einstein-de Sitter universe, the time evolution ofmore » the distribution function can be found exactly and is encapsulated by a time-dependent coupling constant controlling the perturbative expansion. We show that all building blocks of the expansion are free from spurious infrared enhanced contributions that plague the standard cosmological perturbation theory. This paves the way towards the systematic resummation of infrared effects in large scale structure formation. We also argue that the approach proposed here provides a natural framework to account for the influence of short-scale dynamics on larger scales along the lines of effective field theory.« less

  4. The two-point correlation function for groups of galaxies in the Center for Astrophysics redshift survey

    NASA Technical Reports Server (NTRS)

    Ramella, Massimo; Geller, Margaret J.; Huchra, John P.

    1990-01-01

    The large-scale distribution of groups of galaxies selected from complete slices of the CfA redshift survey extension is examined. The survey is used to reexamine the contribution of group members to the galaxy correlation function. The relationship between the correlation function for groups and those calculated for rich clusters is discussed, and the results for groups are examined as an extension of the relation between correlation function amplitude and richness. The group correlation function indicates that groups and individual galaxies are equivalent tracers of the large-scale matter distribution. The distribution of group centers is equivalent to random sampling of the galaxy distribution. The amplitude of the correlation function for groups is consistent with an extrapolation of the amplitude-richness relation for clusters. The amplitude scaled by the mean intersystem separation is also consistent with results for richer clusters.

  5. States of mind: emotions, body feelings, and thoughts share distributed neural networks.

    PubMed

    Oosterwijk, Suzanne; Lindquist, Kristen A; Anderson, Eric; Dautoff, Rebecca; Moriguchi, Yoshiya; Barrett, Lisa Feldman

    2012-09-01

    Scientists have traditionally assumed that different kinds of mental states (e.g., fear, disgust, love, memory, planning, concentration, etc.) correspond to different psychological faculties that have domain-specific correlates in the brain. Yet, growing evidence points to the constructionist hypothesis that mental states emerge from the combination of domain-general psychological processes that map to large-scale distributed brain networks. In this paper, we report a novel study testing a constructionist model of the mind in which participants generated three kinds of mental states (emotions, body feelings, or thoughts) while we measured activity within large-scale distributed brain networks using fMRI. We examined the similarity and differences in the pattern of network activity across these three classes of mental states. Consistent with a constructionist hypothesis, a combination of large-scale distributed networks contributed to emotions, thoughts, and body feelings, although these mental states differed in the relative contribution of those networks. Implications for a constructionist functional architecture of diverse mental states are discussed. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. A quantitative approach to the topology of large-scale structure. [for galactic clustering computation

    NASA Technical Reports Server (NTRS)

    Gott, J. Richard, III; Weinberg, David H.; Melott, Adrian L.

    1987-01-01

    A quantitative measure of the topology of large-scale structure: the genus of density contours in a smoothed density distribution, is described and applied. For random phase (Gaussian) density fields, the mean genus per unit volume exhibits a universal dependence on threshold density, with a normalizing factor that can be calculated from the power spectrum. If large-scale structure formed from the gravitational instability of small-amplitude density fluctuations, the topology observed today on suitable scales should follow the topology in the initial conditions. The technique is illustrated by applying it to simulations of galaxy clustering in a flat universe dominated by cold dark matter. The technique is also applied to a volume-limited sample of the CfA redshift survey and to a model in which galaxies reside on the surfaces of polyhedral 'bubbles'. The topology of the evolved mass distribution and 'biased' galaxy distribution in the cold dark matter models closely matches the topology of the density fluctuations in the initial conditions. The topology of the observational sample is consistent with the random phase, cold dark matter model.

  7. Disappearance of Anisotropic Intermittency in Large-amplitude MHD Turbulence and Its Comparison with Small-amplitude MHD Turbulence

    NASA Astrophysics Data System (ADS)

    Yang, Liping; Zhang, Lei; He, Jiansen; Tu, Chuanyi; Li, Shengtai; Wang, Xin; Wang, Linghua

    2018-03-01

    Multi-order structure functions in the solar wind are reported to display a monofractal scaling when sampled parallel to the local magnetic field and a multifractal scaling when measured perpendicularly. Whether and to what extent will the scaling anisotropy be weakened by the enhancement of turbulence amplitude relative to the background magnetic strength? In this study, based on two runs of the magnetohydrodynamic (MHD) turbulence simulation with different relative levels of turbulence amplitude, we investigate and compare the scaling of multi-order magnetic structure functions and magnetic probability distribution functions (PDFs) as well as their dependence on the direction of the local field. The numerical results show that for the case of large-amplitude MHD turbulence, the multi-order structure functions display a multifractal scaling at all angles to the local magnetic field, with PDFs deviating significantly from the Gaussian distribution and a flatness larger than 3 at all angles. In contrast, for the case of small-amplitude MHD turbulence, the multi-order structure functions and PDFs have different features in the quasi-parallel and quasi-perpendicular directions: a monofractal scaling and Gaussian-like distribution in the former, and a conversion of a monofractal scaling and Gaussian-like distribution into a multifractal scaling and non-Gaussian tail distribution in the latter. These results hint that when intermittencies are abundant and intense, the multifractal scaling in the structure functions can appear even if it is in the quasi-parallel direction; otherwise, the monofractal scaling in the structure functions remains even if it is in the quasi-perpendicular direction.

  8. Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brancucci Martinez-Anido, C.; Hodge, B. M.

    2014-09-01

    This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

  9. Large-scale modeling of rain fields from a rain cell deterministic model

    NASA Astrophysics Data System (ADS)

    FéRal, Laurent; Sauvageot, Henri; Castanet, Laurent; Lemorton, JoëL.; Cornet, FréDéRic; Leconte, Katia

    2006-04-01

    A methodology to simulate two-dimensional rain rate fields at large scale (1000 × 1000 km2, the scale of a satellite telecommunication beam or a terrestrial fixed broadband wireless access network) is proposed. It relies on a rain rate field cellular decomposition. At small scale (˜20 × 20 km2), the rain field is split up into its macroscopic components, the rain cells, described by the Hybrid Cell (HYCELL) cellular model. At midscale (˜150 × 150 km2), the rain field results from the conglomeration of rain cells modeled by HYCELL. To account for the rain cell spatial distribution at midscale, the latter is modeled by a doubly aggregative isotropic random walk, the optimal parameterization of which is derived from radar observations at midscale. The extension of the simulation area from the midscale to the large scale (1000 × 1000 km2) requires the modeling of the weather frontal area. The latter is first modeled by a Gaussian field with anisotropic covariance function. The Gaussian field is then turned into a binary field, giving the large-scale locations over which it is raining. This transformation requires the definition of the rain occupation rate over large-scale areas. Its probability distribution is determined from observations by the French operational radar network ARAMIS. The coupling with the rain field modeling at midscale is immediate whenever the large-scale field is split up into midscale subareas. The rain field thus generated accounts for the local CDF at each point, defining a structure spatially correlated at small scale, midscale, and large scale. It is then suggested that this approach be used by system designers to evaluate diversity gain, terrestrial path attenuation, or slant path attenuation for different azimuth and elevation angle directions.

  10. B-Spline Filtering for Automatic Detection of Calcification Lesions in Mammograms

    NASA Astrophysics Data System (ADS)

    Bueno, G.; Sánchez, S.; Ruiz, M.

    2006-10-01

    Breast cancer continues to be an important health problem between women population. Early detection is the only way to improve breast cancer prognosis and significantly reduce women mortality. It is by using CAD systems that radiologist can improve their ability to detect, and classify lesions in mammograms. In this study the usefulness of using B-spline based on a gradient scheme and compared to wavelet and adaptative filtering has been investigated for calcification lesion detection and as part of CAD systems. The technique has been applied to different density tissues. A qualitative validation shows the success of the method.

  11. Void probability as a function of the void's shape and scale-invariant models. [in studies of spacial galactic distribution

    NASA Technical Reports Server (NTRS)

    Elizalde, E.; Gaztanaga, E.

    1992-01-01

    The dependence of counts in cells on the shape of the cell for the large scale galaxy distribution is studied. A very concrete prediction can be done concerning the void distribution for scale invariant models. The prediction is tested on a sample of the CfA catalog, and good agreement is found. It is observed that the probability of a cell to be occupied is bigger for some elongated cells. A phenomenological scale invariant model for the observed distribution of the counts in cells, an extension of the negative binomial distribution, is presented in order to illustrate how this dependence can be quantitatively determined. An original, intuitive derivation of this model is presented.

  12. The cosmological principle is not in the sky

    NASA Astrophysics Data System (ADS)

    Park, Chan-Gyung; Hyun, Hwasu; Noh, Hyerim; Hwang, Jai-chan

    2017-08-01

    The homogeneity of matter distribution at large scales, known as the cosmological principle, is a central assumption in the standard cosmological model. The case is testable though, thus no longer needs to be a principle. Here we perform a test for spatial homogeneity using the Sloan Digital Sky Survey Luminous Red Galaxies (LRG) sample by counting galaxies within a specified volume with the radius scale varying up to 300 h-1 Mpc. We directly confront the large-scale structure data with the definition of spatial homogeneity by comparing the averages and dispersions of galaxy number counts with allowed ranges of the random distribution with homogeneity. The LRG sample shows significantly larger dispersions of number counts than the random catalogues up to 300 h-1 Mpc scale, and even the average is located far outside the range allowed in the random distribution; the deviations are statistically impossible to be realized in the random distribution. This implies that the cosmological principle does not hold even at such large scales. The same analysis of mock galaxies derived from the N-body simulation, however, suggests that the LRG sample is consistent with the current paradigm of cosmology, thus the simulation is also not homogeneous in that scale. We conclude that the cosmological principle is neither in the observed sky nor demanded to be there by the standard cosmological world model. This reveals the nature of the cosmological principle adopted in the modern cosmology paradigm, and opens a new field of research in theoretical cosmology.

  13. Full-field acoustomammography using an acousto-optic sensor.

    PubMed

    Sandhu, J S; Schmidt, R A; La Rivière, P J

    2009-06-01

    In this Letter the authors introduce a wide-field transmission ultrasound approach to breast imaging based on the use of a large area acousto-optic (AO) sensor. Accompanied by a suitable acoustic source, such a detector could be mounted on a traditional mammography system and provide a mammographylike ultrasound projection image of the compressed breast in registration with the x-ray mammogram. The authors call the approach acoustography. The hope is that this additional information could improve the sensitivity and specificity of screening mammography. The AO sensor converts ultrasound directly into a visual image by virtue of the acousto-optic effect of the liquid crystal layer contained in the AO sensor. The image is captured with a digital video camera for processing, analysis, and storage. In this Letter, the authors perform a geometrical resolution analysis and also present images of a multimodality breast phantom imaged with both mammography and acoustography to demonstrate the feasibility of the approach. The geometric resolution analysis suggests that the technique could readily detect tumors of diameter of 3 mm using 8.5 MHz ultrasound, with smaller tumors detectable with higher frequency ultrasound, though depth penetration might then become a limiting factor. The preliminary phantom images show high contrast and compare favorably to digital mammograms of the same phantom. The authors have introduced and established, through phantom imaging, the feasibility of a full-field transmission ultrasound detector for breast imaging based on the use of a large area AO sensor. Of course variations in attenuation of connective, glandular, and fatty tissues will lead to images with more cluttered anatomical background than those of the phantom imaged here. Acoustic coupling to the mammographically compressed breast, particularly at the margins, will also have to be addressed.

  14. Full-field acoustomammography using an acousto-optic sensor

    PubMed Central

    Sandhu, J. S.; Schmidt, R. A.; La Rivière, P. J.

    2009-01-01

    In this Letter the authors introduce a wide-field transmission ultrasound approach to breast imaging based on the use of a large area acousto-optic (AO) sensor. Accompanied by a suitable acoustic source, such a detector could be mounted on a traditional mammography system and provide a mammographylike ultrasound projection image of the compressed breast in registration with the x-ray mammogram. The authors call the approach acoustography. The hope is that this additional information could improve the sensitivity and specificity of screening mammography. The AO sensor converts ultrasound directly into a visual image by virtue of the acousto-optic effect of the liquid crystal layer contained in the AO sensor. The image is captured with a digital video camera for processing, analysis, and storage. In this Letter, the authors perform a geometrical resolution analysis and also present images of a multimodality breast phantom imaged with both mammography and acoustography to demonstrate the feasibility of the approach. The geometric resolution analysis suggests that the technique could readily detect tumors of diameter of 3 mm using 8.5 MHz ultrasound, with smaller tumors detectable with higher frequency ultrasound, though depth penetration might then become a limiting factor. The preliminary phantom images show high contrast and compare favorably to digital mammograms of the same phantom. The authors have introduced and established, through phantom imaging, the feasibility of a full-field transmission ultrasound detector for breast imaging based on the use of a large area AO sensor. Of course variations in attenuation of connective, glandular, and fatty tissues will lead to images with more cluttered anatomical background than those of the phantom imaged here. Acoustic coupling to the mammographically compressed breast, particularly at the margins, will also have to be addressed. PMID:19610321

  15. A completely automated CAD system for mass detection in a large mammographic database.

    PubMed

    Bellotti, R; De Carlo, F; Tangaro, S; Gargano, G; Maggipinto, G; Castellano, M; Massafra, R; Cascio, D; Fauci, F; Magro, R; Raso, G; Lauria, A; Forni, G; Bagnasco, S; Cerello, P; Zanon, E; Cheran, S C; Lopez Torres, E; Bottigli, U; Masala, G L; Oliva, P; Retico, A; Fantacci, M E; Cataldo, R; De Mitri, I; De Nunzio, G

    2006-08-01

    Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.

  16. Fixed-facility workplace screening mammography.

    PubMed

    Reynolds, H E; Larkin, G N; Jackson, V P; Hawes, D R

    1997-02-01

    Potential barriers to compliance with screening mammography guidelines include the cost and inconvenience involved with undergoing the procedure. Workplace screening with mobile mammography is one possible approach to the convenience barrier. However, fixed-facility workplace screening is a viable alternative for any company with a large workforce in one location. This paper describes our initial experience with one such fixed facility. The facility was a cooperative venture by a large pharmaceutical company and an academic radiology department to provide convenient, no-cost (to the patient) screening mammography to employees, dependents, and retirees more than 40 years old. The pharmaceutical company built the facility within its corporate headquarters and the academic radiology department provided the equipment and personnel. The company was billed a fixed cost per examination. In the first 22 months of operation, 4210 (of 4559 scheduled) screening mammograms were obtained. The mean age of the population was 53 years old. Ninety percent of the screening mammograms were interpreted as negative or benign; 10% required additional workup. Of the screened population, 62 biopsies were recommended and 60 were performed. Of these, 42 were benign and 18 malignant. The cancer detection rate was 4.3 per 1000 (0.43%). At the time of diagnosis, six patients were stage 0, 10 patients were stage I, one patient was stage II, and one patient was stage III. Eleven of the 18 patients had minimal cancers. Of the patients who completed a satisfaction survey, 97% percent expressed a high degree of satisfaction with the screening process and stated they would use the facility in the future. A fixed facility for workplace screening mammography is a viable way to provide nearly barrier-free access to high-quality mammography. Patient acceptance is high.

  17. Extracting Useful Semantic Information from Large Scale Corpora of Text

    ERIC Educational Resources Information Center

    Mendoza, Ray Padilla, Jr.

    2012-01-01

    Extracting and representing semantic information from large scale corpora is at the crux of computer-assisted knowledge generation. Semantic information depends on collocation extraction methods, mathematical models used to represent distributional information, and weighting functions which transform the space. This dissertation provides a…

  18. Biotic and abiotic factors predicting the global distribution and population density of an invasive large mammal

    PubMed Central

    Lewis, Jesse S.; Farnsworth, Matthew L.; Burdett, Chris L.; Theobald, David M.; Gray, Miranda; Miller, Ryan S.

    2017-01-01

    Biotic and abiotic factors are increasingly acknowledged to synergistically shape broad-scale species distributions. However, the relative importance of biotic and abiotic factors in predicting species distributions is unclear. In particular, biotic factors, such as predation and vegetation, including those resulting from anthropogenic land-use change, are underrepresented in species distribution modeling, but could improve model predictions. Using generalized linear models and model selection techniques, we used 129 estimates of population density of wild pigs (Sus scrofa) from 5 continents to evaluate the relative importance, magnitude, and direction of biotic and abiotic factors in predicting population density of an invasive large mammal with a global distribution. Incorporating diverse biotic factors, including agriculture, vegetation cover, and large carnivore richness, into species distribution modeling substantially improved model fit and predictions. Abiotic factors, including precipitation and potential evapotranspiration, were also important predictors. The predictive map of population density revealed wide-ranging potential for an invasive large mammal to expand its distribution globally. This information can be used to proactively create conservation/management plans to control future invasions. Our study demonstrates that the ongoing paradigm shift, which recognizes that both biotic and abiotic factors shape species distributions across broad scales, can be advanced by incorporating diverse biotic factors. PMID:28276519

  19. Recurrent patterning in the daily foraging routes of hamadryas baboons (Papio hamadryas): spatial memory in large-scale versus small-scale space.

    PubMed

    Schreier, Amy L; Grove, Matt

    2014-05-01

    The benefits of spatial memory for foraging animals can be assessed on two distinct spatial scales: small-scale space (travel within patches) and large-scale space (travel between patches). While the patches themselves may be distributed at low density, within patches resources are likely densely distributed. We propose, therefore, that spatial memory for recalling the particular locations of previously visited feeding sites will be more advantageous during between-patch movement, where it may reduce the distances traveled by animals that possess this ability compared to those that must rely on random search. We address this hypothesis by employing descriptive statistics and spectral analyses to characterize the daily foraging routes of a band of wild hamadryas baboons in Filoha, Ethiopia. The baboons slept on two main cliffs--the Filoha cliff and the Wasaro cliff--and daily travel began and ended on a cliff; thus four daily travel routes exist: Filoha-Filoha, Filoha-Wasaro, Wasaro-Wasaro, Wasaro-Filoha. We use newly developed partial sum methods and distribution-fitting analyses to distinguish periods of area-restricted search from more extensive movements. The results indicate a single peak in travel activity in the Filoha-Filoha and Wasaro-Filoha routes, three peaks of travel activity in the Filoha-Wasaro routes, and two peaks in the Wasaro-Wasaro routes; and are consistent with on-the-ground observations of foraging and ranging behavior of the baboons. In each of the four daily travel routes the "tipping points" identified by the partial sum analyses indicate transitions between travel in small- versus large-scale space. The correspondence between the quantitative analyses and the field observations suggest great utility for using these types of analyses to examine primate travel patterns and especially in distinguishing between movement in small versus large-scale space. Only the distribution-fitting analyses are inconsistent with the field observations, which may be due to the scale at which these analyses were conducted. © 2013 Wiley Periodicals, Inc.

  20. Real Time Text Analysis

    NASA Astrophysics Data System (ADS)

    Senthilkumar, K.; Ruchika Mehra Vijayan, E.

    2017-11-01

    This paper aims to illustrate real time analysis of large scale data. For practical implementation we are performing sentiment analysis on live Twitter feeds for each individual tweet. To analyze sentiments we will train our data model on sentiWordNet, a polarity assigned wordNet sample by Princeton University. Our main objective will be to efficiency analyze large scale data on the fly using distributed computation. Apache Spark and Apache Hadoop eco system is used as distributed computation platform with Java as development language

  1. The Large Scale Distribution of Water Ice in the Polar Regions of the Moon

    NASA Astrophysics Data System (ADS)

    Jordan, A.; Wilson, J. K.; Schwadron, N.; Spence, H. E.

    2017-12-01

    For in situ resource utilization, one must know where water ice is on the Moon. Many datasets have revealed both surface deposits of water ice and subsurface deposits of hydrogen near the lunar poles, but it has proved difficult to resolve the differences among the locations of these deposits. Despite these datasets disagreeing on how deposits are distributed on small scales, we show that most of these datasets do agree on the large scale distribution of water ice. We present data from the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) on the Lunar Reconnaissance Orbiter (LRO), LRO's Lunar Exploration Neutron Detector (LEND), the Neutron Spectrometer on Lunar Prospector (LPNS), LRO's Lyman Alpha Mapping Project (LAMP), LRO's Lunar Orbiter Laser Altimeter (LOLA), and Chandrayaan-1's Moon Mineralogy Mapper (M3). All, including those that show clear evidence for water ice, reveal surprisingly similar trends with latitude, suggesting that both surface and subsurface datasets are measuring ice. All show that water ice increases towards the poles, and most demonstrate that its signature appears at about ±70° latitude and increases poleward. This is consistent with simulations of how surface and subsurface cold traps are distributed with latitude. This large scale agreement constrains the origin of the ice, suggesting that an ancient cometary impact (or impacts) created a large scale deposit that has been rendered locally heterogeneous by subsequent impacts. Furthermore, it also shows that water ice may be available down to ±70°—latitudes that are more accessible than the poles for landing.

  2. Reconstruction of spatial distributions of sound velocity and absorption in soft biological tissues using model ultrasonic tomographic data

    NASA Astrophysics Data System (ADS)

    Burov, V. A.; Zotov, D. I.; Rumyantseva, O. D.

    2014-07-01

    A two-step algorithm is used to reconstruct the spatial distributions of the acoustic characteristics of soft biological tissues-the sound velocity and absorption coefficient. Knowing these distributions is urgent for early detection of benign and malignant neoplasms in biological tissues, primarily in the breast. At the first stage, large-scale distributions are estimated; at the second step, they are refined with a high resolution. Results of reconstruction on the base of model initial data are presented. The principal necessity of preliminary reconstruction of large-scale distributions followed by their being taken into account at the second step is illustrated. The use of CUDA technology for processing makes it possible to obtain final images of 1024 × 1024 samples in only a few minutes.

  3. Prevalence of Mammographically Dense Breasts in the United States

    PubMed Central

    Gangnon, Ronald E.; Burt, Veronica; Trentham-Dietz, Amy; Hampton, John M.; Wellman, Robert D.; Kerlikowske, Karla; Miglioretti, Diana L.

    2014-01-01

    Background National legislation is under consideration that would require women with mammographically dense breasts to be informed of their breast density and encouraged to discuss supplemental breast cancer screening with their health care providers. The number of US women potentially affected by this legislation is unknown. Methods We determined the mammographic breast density distribution by age and body mass index (BMI) using data from 1518 599 mammograms conducted from 2007 through 2010 at mammography facilities in the Breast Cancer Surveillance Consortium (BCSC). We applied these breast density distributions to age- and BMI-specific counts of the US female population derived from the 2010 US Census and the National Health and Nutrition Examination Survey (NHANES) to estimate the number of US women with dense breasts. Results Overall, 43.3% (95% confidence interval [CI] = 43.1% to 43.4%) of women 40 to 74 years of age had heterogeneously or extremely dense breasts, and this proportion was inversely associated with age and BMI. Based on the age and BMI distribution of US women, we estimated that 27.6 million women (95% CI = 27.5 to 27.7 million) aged 40 to 74 years in the United States have heterogeneously or extremely dense breasts. Women aged 40 to 49 years (N = 12.3 million) accounted for 44.3% of this group. Conclusion The prevalence of dense breasts among US women of common breast cancer screening ages exceeds 25 million. Policymakers and healthcare providers should consider this large prevalence when debating breast density notification legislation and designing strategies to ensure that women who are notified have opportunities to evaluate breast cancer risk and discuss and pursue supplemental screening options if deemed appropriate. PMID:25217577

  4. Linear velocity fields in non-Gaussian models for large-scale structure

    NASA Technical Reports Server (NTRS)

    Scherrer, Robert J.

    1992-01-01

    Linear velocity fields in two types of physically motivated non-Gaussian models are examined for large-scale structure: seed models, in which the density field is a convolution of a density profile with a distribution of points, and local non-Gaussian fields, derived from a local nonlinear transformation on a Gaussian field. The distribution of a single component of the velocity is derived for seed models with randomly distributed seeds, and these results are applied to the seeded hot dark matter model and the global texture model with cold dark matter. An expression for the distribution of a single component of the velocity in arbitrary local non-Gaussian models is given, and these results are applied to such fields with chi-squared and lognormal distributions. It is shown that all seed models with randomly distributed seeds and all local non-Guassian models have single-component velocity distributions with positive kurtosis.

  5. Development of a national electronic interval cancer review for breast screening

    NASA Astrophysics Data System (ADS)

    Halling-Brown, M. D.; Patel, M. N.; Wallis, M. G.; Young, K. C.

    2018-03-01

    Reviewing interval cancers and prior screening mammograms are a key measure to monitor screening performance. Radiological analysis of the imaging features in prior mammograms and retrospective classification are an important educational tool for readers to improve individual performance. The requirements of remote, collaborative image review sessions, such as those required to run a remote interval cancer review, are variable and demand a flexible and configurable software solution that is not currently available on commercial workstations. The wide range of requirements for both collection and remote review of interval cancers has precipitated the creation of extensible medical image viewers and accompanying systems. In order to allow remote viewing, an application has been designed to allow workstation-independent, PACS-less viewing and interaction with medical images in a remote, collaborative manner, providing centralised reporting and web-based feedback. A semi-automated process, which allows the centralisation of interval cancer cases, has been developed. This stand-alone, flexible image collection toolkit provides the extremely important function of bespoke, ad-hoc image collection at sites where there is no dedicated hardware. Web interfaces have been created which allow a national or regional administrator to organise, coordinate and administer interval cancer review sessions and deploy invites to session members to participate. The same interface allows feedback to be analysed and distributed. The eICR provides a uniform process for classifying interval cancers across the NHSBSP, which facilitates rapid access to a robust 'external' review for patients and their relatives seeking answers about why their cancer was 'missed'.

  6. Computerized image analysis: estimation of breast density on mammograms

    NASA Astrophysics Data System (ADS)

    Zhou, Chuan; Chan, Heang-Ping; Petrick, Nicholas; Sahiner, Berkman; Helvie, Mark A.; Roubidoux, Marilyn A.; Hadjiiski, Lubomir M.; Goodsitt, Mitchell M.

    2000-06-01

    An automated image analysis tool is being developed for estimation of mammographic breast density, which may be useful for risk estimation or for monitoring breast density change in a prevention or intervention program. A mammogram is digitized using a laser scanner and the resolution is reduced to a pixel size of 0.8 mm X 0.8 mm. Breast density analysis is performed in three stages. First, the breast region is segmented from the surrounding background by an automated breast boundary-tracking algorithm. Second, an adaptive dynamic range compression technique is applied to the breast image to reduce the range of the gray level distribution in the low frequency background and to enhance the differences in the characteristic features of the gray level histogram for breasts of different densities. Third, rule-based classification is used to classify the breast images into several classes according to the characteristic features of their gray level histogram. For each image, a gray level threshold is automatically determined to segment the dense tissue from the breast region. The area of segmented dense tissue as a percentage of the breast area is then estimated. In this preliminary study, we analyzed the interobserver variation of breast density estimation by two experienced radiologists using BI-RADS lexicon. The radiologists' visually estimated percent breast densities were compared with the computer's calculation. The results demonstrate the feasibility of estimating mammographic breast density using computer vision techniques and its potential to improve the accuracy and reproducibility in comparison with the subjective visual assessment by radiologists.

  7. Mammographic density measured as changes in tissue structure caused by HRT

    NASA Astrophysics Data System (ADS)

    Raundahl, Jakob; Loog, Marco; Nielsen, Mads

    2006-03-01

    Numerous studies have investigated the relation between mammographic density and breast cancer risk. These studies indicate that women with high breast density have a four to six fold risk increase. An investigation of whether or not this relation is causal is important for, e.g., hormone replacement therapy (HRT), which has been shown to actually increase the density. No gold standard for automatic assessment of mammographic density exists. Manual methods such as Wolfe patterns and BI-RADS are helpful for communication of diagnostic sensitivity, but they are both time consuming and crude. They may be sufficient in certain cases and for single measurements, but for serial, temporal analysis it is necessary to be able to detect more subtle changes and, in addition, to be more reproducible. In this work an automated method for measuring the effect of HRT w.r.t. changes in biological density in the breast is presented. This measure is a novel measure, which provides structural information orthogonal to intensity-based methods. Hessian eigenvalues at different scales are used as features and a clustering of these is employed to divide a mammogram into four structurally different areas. Subsequently, based on the relative size of the areas, a density score is determined. In the experiments, two sets of mammograms of 50 patients from a double blind, placebo controlled HRT experiment were used. The change in density for the HRT group, measured with the new method, was significantly higher (p = 0.0002) than the change in the control group.

  8. Bridging the gap between small and large scale sediment budgets? - A scaling challenge in the Upper Rhone Basin, Switzerland

    NASA Astrophysics Data System (ADS)

    Schoch, Anna; Blöthe, Jan; Hoffmann, Thomas; Schrott, Lothar

    2016-04-01

    A large number of sediment budgets have been compiled on different temporal and spatial scales in alpine regions. Detailed sediment budgets based on the quantification of a number of sediment storages (e.g. talus cones, moraine deposits) exist only for a few small scale drainage basins (up to 10² km²). In contrast, large scale sediment budgets (> 10³ km²) consider only long term sediment sinks such as valley fills and lakes. Until now, these studies often neglect small scale sediment storages in the headwaters. However, the significance of these sediment storages have been reported. A quantitative verification whether headwaters function as sediment source regions is lacking. Despite substantial transport energy in mountain environments due to steep gradients and high relief, sediment flux in large river systems is frequently disconnected from alpine headwaters. This leads to significant storage of coarse-grained sediment along the flow path from rockwall source regions to large sedimentary sinks in major alpine valleys. To improve the knowledge on sediment budgets in large scale alpine catchments and to bridge the gap between small and large scale sediment budgets, we apply a multi-method approach comprising investigations on different spatial scales in the Upper Rhone Basin (URB). The URB is the largest inneralpine basin in the European Alps with a size of > 5400 km². It is a closed system with Lake Geneva acting as an ultimate sediment sink for suspended and clastic sediment. We examine the spatial pattern and volumes of sediment storages as well as the morphometry on the local and catchment-wide scale. We mapped sediment storages and bedrock in five sub-regions of the study area (Goms, Lötschen valley, Val d'Illiez, Vallée de la Liène, Turtmann valley) in the field and from high-resolution remote sensing imagery to investigate the spatial distribution of different sediment storage types (e.g. talus deposits, debris flow cones, alluvial fans). These sub-regions cover all three litho-tectonic units of the URB (Helvetic nappes, Penninic nappes, External massifs) and different catchment sizes to capture the inherent variability. Different parameters characterizing topography, surface characteristics, and vegetation cover are analyzed for each storage type. The data is then used in geostatistical models (PCA, stepwise logistic regression) to predict the spatial distribution of sediment storage for the whole URB. We further conduct morphometric analyses of the URB to gain information on the varying degree of glacial imprint and postglacial landscape evolution and their control on the spatial distribution of sediment storage in a large scale drainage basin. Geophysical methods (ground penetrating radar and electrical resistivity tomography) are applied on different sediment storage types on the local scale to estimate mean thicknesses. Additional data from published studies are used to complement our dataset. We integrate the local data in the statistical model on the spatial distribution of sediment storages for the whole URB. Hence, we can extrapolate the stored sediment volumes to the regional scale in order to bridge the gap between small and large scale studies.

  9. Void probability as a function of the void's shape and scale-invariant models

    NASA Technical Reports Server (NTRS)

    Elizalde, E.; Gaztanaga, E.

    1991-01-01

    The dependence of counts in cells on the shape of the cell for the large scale galaxy distribution is studied. A very concrete prediction can be done concerning the void distribution for scale invariant models. The prediction is tested on a sample of the CfA catalog, and good agreement is found. It is observed that the probability of a cell to be occupied is bigger for some elongated cells. A phenomenological scale invariant model for the observed distribution of the counts in cells, an extension of the negative binomial distribution, is presented in order to illustrate how this dependence can be quantitatively determined. An original, intuitive derivation of this model is presented.

  10. Determining maximum stand density index in mixed species stands for strategic-scale stocking assessments

    Treesearch

    Chris W. Woodall; Patrick D. Miles; John S. Vissage

    2005-01-01

    Stand density index (SDI), although developed for use in even-aged monocultures, has been used for assessing stand density in large-scale forest inventories containing diverse tree species and size distributions. To improve application of SDI in unevenaged, mixed species stands present in large-scale forest inventories, trends in maximum SDI across diameter classes...

  11. "We get by with a little help from our friends": Small-scale informal and large-scale formal peer distribution networks of sterile injecting equipment in Australia.

    PubMed

    Newland, Jamee; Newman, Christy; Treloar, Carla

    2016-08-01

    In Australia, sterile needles and syringes are distributed to people who inject drugs (PWID) through formal services for the purposes of preventing blood borne viruses (BBV). Peer distribution involves people acquiring needles from formal services and redistributing them to others. This paper investigates the dynamics of the distribution of sterile injecting equipment among networks of people who inject drugs in four sites in New South Wales (NSW), Australia. Qualitative data exploring the practice of peer distribution were collected through in-depth, semi-structured interviews and participatory social network mapping. These interviews explored injecting equipment demand, access to services, relationship pathways through which peer distribution occurred, an estimate of the size of the different peer distribution roles and participants' understanding of the illegality of peer distribution in NSW. Data were collected from 32 participants, and 31 (98%) reported participating in peer distribution in the months prior to interview. Of those 31 participants, five reported large-scale formal distribution, with an estimated volume of 34,970 needles and syringes annually. Twenty-two participated in reciprocal exchange, where equipment was distributed and received on an informal basis that appeared dependent on context and circumstance and four participants reported recipient peer distribution as their only access to sterile injecting equipment. Most (n=27) were unaware that it was illegal to distribute injecting equipment to their peers. Peer distribution was almost ubiquitous amongst the PWID participating in the study, and although five participants reported taking part in the highly organised, large-scale distribution of injecting equipment for altruistic reasons, peer distribution was more commonly reported to take place in small networks of friends and/or partners for reasons of convenience. The law regarding the illegality of peer distribution needs to change so that NSPs can capitalise on peer distribution to increase the options available to PWID and to acknowledge PWID as essential harm reduction agents in the prevention of BBVs. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Automated assessment of bilateral breast volume asymmetry as a breast cancer biomarker during mammographic screening

    NASA Astrophysics Data System (ADS)

    Williams, Alex C.; Hitt, Austin; Voisin, Sophie; Tourassi, Georgia

    2013-03-01

    The biological concept of bilateral symmetry as a marker of developmental stability and good health is well established. Although most individuals deviate slightly from perfect symmetry, humans are essentially considered bilaterally symmetrical. Consequently, increased fluctuating asymmetry of paired structures could be an indicator of disease. There are several published studies linking bilateral breast size asymmetry with increased breast cancer risk. These studies were based on radiologists' manual measurements of breast size from mammographic images. We aim to develop a computerized technique to assess fluctuating breast volume asymmetry in screening mammograms and investigate whether it correlates with the presence of breast cancer. Using a large database of screening mammograms with known ground truth we applied automated breast region segmentation and automated breast size measurements in CC and MLO views using three well established methods. All three methods confirmed that indeed patients with breast cancer have statistically significantly higher fluctuating asymmetry of their breast volumes. However, statistically significant difference between patients with cancer and benign lesions was observed only for the MLO views. The study suggests that automated assessment of global bilateral asymmetry could serve as a breast cancer risk biomarker for women undergoing mammographic screening. Such biomarker could be used to alert radiologists or computer-assisted detection (CAD) systems to exercise increased vigilance if higher than normal cancer risk is suspected.

  13. A deep learning approach for the analysis of masses in mammograms with minimal user intervention.

    PubMed

    Dhungel, Neeraj; Carneiro, Gustavo; Bradley, Andrew P

    2017-04-01

    We present an integrated methodology for detecting, segmenting and classifying breast masses from mammograms with minimal user intervention. This is a long standing problem due to low signal-to-noise ratio in the visualisation of breast masses, combined with their large variability in terms of shape, size, appearance and location. We break the problem down into three stages: mass detection, mass segmentation, and mass classification. For the detection, we propose a cascade of deep learning methods to select hypotheses that are refined based on Bayesian optimisation. For the segmentation, we propose the use of deep structured output learning that is subsequently refined by a level set method. Finally, for the classification, we propose the use of a deep learning classifier, which is pre-trained with a regression to hand-crafted feature values and fine-tuned based on the annotations of the breast mass classification dataset. We test our proposed system on the publicly available INbreast dataset and compare the results with the current state-of-the-art methodologies. This evaluation shows that our system detects 90% of masses at 1 false positive per image, has a segmentation accuracy of around 0.85 (Dice index) on the correctly detected masses, and overall classifies masses as malignant or benign with sensitivity (Se) of 0.98 and specificity (Sp) of 0.7. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Latitudinal variability of large-scale coronal temperature and its association with the density and the global magnetic field

    NASA Technical Reports Server (NTRS)

    Guhathakurta, M.; Fisher, R. R.

    1994-01-01

    In this paper we utilize the latitiude distribution of the coronal temperature during the period 1984-1992 that was derived in a paper by Guhathakurta et al, 1993, utilizing ground-based intensity observations of the green (5303 A Fe XIV) and red (6374 A Fe X) coronal forbidden lines from the National Solar Observatory at Sacramento Peak, and establish it association with the global magnetic field and the density distributions in the corona. A determination of plasma temperature, T, was estimated from the intensity ratio Fe X/Fe XIV (where T is inversely proportional to the ratio), since both emission lines come from ionized states of Fe, and the ratio is only weakly dependent on density. We observe that there is a large-scale organization of the inferred coronal temperature distribution that is associated with the large-scale, weak magnetic field structures and bright coronal features; this organization tends to persist through most of the magnetic activity cycle. These high-temperature structures exhibit time-space characteristics which are similar to those of the polar crown filaments. This distribution differs in spatial and temporal characterization from the traditional picture of sunspot and active region evolution over the range of the sunspot cycle, which are manifestations of the small-scale, strong magnetic field regions.

  15. Mems: Platform for Large-Scale Integrated Vacuum Electronic Circuits

    DTIC Science & Technology

    2017-03-20

    SECURITY CLASSIFICATION OF: The objective of the LIVEC advanced study project was to develop a platform for large-scale integrated vacuum electronic ...Distribution Unlimited UU UU UU UU 20-03-2017 1-Jul-2014 30-Jun-2015 Final Report: MEMS Platform for Large-Scale Integrated Vacuum Electronic ... Electronic Circuits (LIVEC) Contract No: W911NF-14-C-0093 COR Dr. James Harvey U.S. ARO RTP, NC 27709-2211 Phone: 702-696-2533 e-mail

  16. Landscape-scale distribution and persistence of genetically modified oilseed rape (Brassica napus) in Manitoba, Canada.

    PubMed

    Knispel, Alexis L; McLachlan, Stéphane M

    2010-01-01

    Genetically modified herbicide-tolerant (GMHT) oilseed rape (OSR; Brassica napus L.) was approved for commercial cultivation in Canada in 1995 and currently represents over 95% of the OSR grown in western Canada. After a decade of widespread cultivation, GMHT volunteers represent an increasing management problem in cultivated fields and are ubiquitous in adjacent ruderal habitats, where they contribute to the spread of transgenes. However, few studies have considered escaped GMHT OSR populations in North America, and even fewer have been conducted at large spatial scales (i.e. landscape scales). In particular, the contribution of landscape structure and large-scale anthropogenic dispersal processes to the persistence and spread of escaped GMHT OSR remains poorly understood. We conducted a multi-year survey of the landscape-scale distribution of escaped OSR plants adjacent to roads and cultivated fields. Our objective was to examine the long-term dynamics of escaped OSR at large spatial scales and to assess the relative importance of landscape and localised factors to the persistence and spread of these plants outside of cultivation. From 2005 to 2007, we surveyed escaped OSR plants along roadsides and field edges at 12 locations in three agricultural landscapes in southern Manitoba where GMHT OSR is widely grown. Data were analysed to examine temporal changes at large spatial scales and to determine factors affecting the distribution of escaped OSR plants in roadside and field edge habitats within agricultural landscapes. Additionally, we assessed the potential for seed dispersal between escaped populations by comparing the relative spatial distribution of roadside and field edge OSR. Densities of escaped OSR fluctuated over space and time in both roadside and field edge habitats, though the proportion of GMHT plants was high (93-100%). Escaped OSR was positively affected by agricultural landscape (indicative of cropping intensity) and by the presence of an adjacent field planted to OSR. Within roadside habitats, escaped OSR was also strongly associated with large-scale variables, including road surface (indicative of traffic intensity) and distance to the nearest grain elevator. Conversely, within field edges, OSR density was affected by localised crop management practices such as mowing, soil disturbance and herbicide application. Despite the proximity of roadsides and field edges, there was little evidence of spatial aggregation among escaped OSR populations in these two habitats, especially at very fine spatial scales (i.e. <100 m), suggesting that natural propagule exchange is infrequent. Escaped OSR populations were persistent at large spatial and temporal scales, and low density in a given landscape or year was not indicative of overall extinction. As a result of ongoing cultivation and transport of OSR crops, escaped GMHT traits will likely remain predominant in agricultural landscapes. While escaped OSR in field edge habitats generally results from local seeding and management activities occurring at the field-scale, distribution patterns within roadside habitats are determined in large part by seed transport occurring at the landscape scale and at even larger regional scales. Our findings suggest that these large-scale anthropogenic dispersal processes are sufficient to enable persistence despite limited natural seed dispersal. This widespread dispersal is likely to undermine field-scale management practices aimed at eliminating escaped and in-field GMHT OSR populations. Agricultural transport and landscape-scale cropping patterns are important determinants of the distribution of escaped GM crops. At the regional level, these factors ensure ongoing establishment and spread of escaped GMHT OSR despite limited local seed dispersal. Escaped populations thus play an important role in the spread of transgenes and have substantial implications for the coexistence of GM and non-GM production systems. Given the large-scale factors driving the spread of escaped transgenes, localised co-existence measures may be impracticable where they are not commensurate with regional dispersal mechanisms. To be effective, strategies aimed at reducing contamination from GM crops should be multi-scale in approach and be developed and implemented at both farm and landscape levels of organisation. Multiple stakeholders should thus be consulted, including both GM and non-GM farmers, as well as seed developers, processors, transporters and suppliers. Decisions to adopt GM crops require thoughtful and inclusive consideration of the risks and responsibilities inherent in this new technology.

  17. Screen-Space Normal Distribution Function Caching for Consistent Multi-Resolution Rendering of Large Particle Data.

    PubMed

    Ibrahim, Mohamed; Wickenhauser, Patrick; Rautek, Peter; Reina, Guido; Hadwiger, Markus

    2018-01-01

    Molecular dynamics (MD) simulations are crucial to investigating important processes in physics and thermodynamics. The simulated atoms are usually visualized as hard spheres with Phong shading, where individual particles and their local density can be perceived well in close-up views. However, for large-scale simulations with 10 million particles or more, the visualization of large fields-of-view usually suffers from strong aliasing artifacts, because the mismatch between data size and output resolution leads to severe under-sampling of the geometry. Excessive super-sampling can alleviate this problem, but is prohibitively expensive. This paper presents a novel visualization method for large-scale particle data that addresses aliasing while enabling interactive high-quality rendering. We introduce the novel concept of screen-space normal distribution functions (S-NDFs) for particle data. S-NDFs represent the distribution of surface normals that map to a given pixel in screen space, which enables high-quality re-lighting without re-rendering particles. In order to facilitate interactive zooming, we cache S-NDFs in a screen-space mipmap (S-MIP). Together, these two concepts enable interactive, scale-consistent re-lighting and shading changes, as well as zooming, without having to re-sample the particle data. We show how our method facilitates the interactive exploration of real-world large-scale MD simulation data in different scenarios.

  18. Reader variability in breast density estimation from full-field digital mammograms: the effect of image postprocessing on relative and absolute measures.

    PubMed

    Keller, Brad M; Nathan, Diane L; Gavenonis, Sara C; Chen, Jinbo; Conant, Emily F; Kontos, Despina

    2013-05-01

    Mammographic breast density, a strong risk factor for breast cancer, may be measured as either a relative percentage of dense (ie, radiopaque) breast tissue or as an absolute area from either raw (ie, "for processing") or vendor postprocessed (ie, "for presentation") digital mammograms. Given the increasing interest in the incorporation of mammographic density in breast cancer risk assessment, the purpose of this study is to determine the inherent reader variability in breast density assessment from raw and vendor-processed digital mammograms, because inconsistent estimates could to lead to misclassification of an individual woman's risk for breast cancer. Bilateral, mediolateral-oblique view, raw, and processed digital mammograms of 81 women were retrospectively collected for this study (N = 324 images). Mammographic percent density and absolute dense tissue area estimates for each image were obtained from two radiologists using a validated, interactive software tool. The variability of interreader agreement was not found to be affected by the image presentation style (ie, raw or processed, F-test: P > .5). Interreader estimates of relative and absolute breast density are strongly correlated (Pearson r > 0.84, P < .001) but systematically different (t-test, P < .001) between the two readers. Our results show that mammographic density may be assessed with equal reliability from either raw or vendor postprocessed images. Furthermore, our results suggest that the primary source of density variability comes from the subjectivity of the individual reader in assessing the absolute amount of dense tissue present in the breast, indicating the need to use standardized tools to mitigate this effect. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  19. Breast screening: What can the interval cancer review teach us? Are we perhaps being a bit too hard on ourselves?

    PubMed

    Lekanidi, Katerina; Dilks, Phil; Suaris, Tamara; Kennett, Steffan; Purushothaman, Hema

    2017-09-01

    The aim of this study was to determine the features that make interval cancers apparent on the preceding screening mammogram and determine whether changes in the ways of performing the interval cancer review will affect the true interval cancer rate. This study was approved by the clinical governance committee. Mammograms of women diagnosed with an interval cancer were included in the study if they had been allocated to either the "suspicious signs" group or "subtle signs" group, during the historic interval cancer review. Three radiologists, individually and blinded to the site of interval cancer, reviewed the mammograms and documented the presence, site, characteristics and classification of any abnormality. Findings were compared with the appearances of the abnormality at the site of subsequent cancer development by a different breast radiologist. The chi-squared test was used in the analysis of the results, seeking associations between recall concordance and cancer mammographic or histological characteristics. 111/590 interval cancers fulfilled the study inclusion criteria. In 17% of the cases none of the readers identified the relevant abnormality on the screening mammogram. 1/3 readers identified the relevant lesion in 22% of the cases, 2/3 readers in 28% of cases and all 3 readers in 33% of cases. The commonest unanimously recalled abnormality was microcalcification and the most challenging mammographic abnormality to detect was asymmetric density. We did not find any statistically significant association between recall concordance and time to interval cancer, position of lesion in the breast, breast density or cancer grade. Even the simple step of performing an independent blinded review of interval cancers reduces the rate of interval cancers classified as missed by up to 39%. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Temporal assessment of radiomic features on clinical mammography in a high-risk population

    NASA Astrophysics Data System (ADS)

    Mendel, Kayla R.; Li, Hui; Lan, Li; Chan, Chun-Wai; King, Lauren M.; Tayob, Nabihah; Whitman, Gary; El-Zein, Randa; Bedrosian, Isabelle; Giger, Maryellen L.

    2018-02-01

    Extraction of high-dimensional quantitative data from medical images has become necessary in disease risk assessment, diagnostics and prognostics. Radiomic workflows for mammography typically involve a single medical image for each patient although medical images may exist for multiple imaging exams, especially in screening protocols. Our study takes advantage of the availability of mammograms acquired over multiple years for the prediction of cancer onset. This study included 841 images from 328 patients who developed subsequent mammographic abnormalities, which were confirmed as either cancer (n=173) or non-cancer (n=155) through diagnostic core needle biopsy. Quantitative radiomic analysis was conducted on antecedent FFDMs acquired a year or more prior to diagnostic biopsy. Analysis was limited to the breast contralateral to that in which the abnormality arose. Novel metrics were used to identify robust radiomic features. The most robust features were evaluated in the task of predicting future malignancies on a subset of 72 subjects (23 cancer cases and 49 non-cancer controls) with mammograms over multiple years. Using linear discriminant analysis, the robust radiomic features were merged into predictive signatures by: (i) using features from only the most recent contralateral mammogram, (ii) change in feature values between mammograms, and (iii) ratio of feature values over time, yielding AUCs of 0.57 (SE=0.07), 0.63 (SE=0.06), and 0.66 (SE=0.06), respectively. The AUCs for temporal radiomics (ratio) statistically differed from chance, suggesting that changes in radiomics over time may be critical for risk assessment. Overall, we found that our two-stage process of robustness assessment followed by performance evaluation served well in our investigation on the role of temporal radiomics in risk assessment.

  1. Screening Mammography Use Among Older Women Before and After the 2009 U.S. Preventive Services Task Force Recommendations.

    PubMed

    Chang, Chiang-Hua; Bynum, Julie P W; Onega, Tracy; Colla, Carrie H; Lurie, Jon D; Tosteson, Anna N A

    2016-10-01

    It is uncertain how changes in the U.S. Preventive Services Task Force breast cancer screening recommendations (from annual to biennial mammography screening in women aged 50-74 and grading the evidence as insufficient for screening in women aged 75 and older) have affected mammography use among Medicare beneficiaries. Cohort study of 12 million Medicare fee-for-service women aged 65-74 and 75 and older to measure changes in 3-year screening use, 2007-2009 (before) and 2010-2012 (after), defined by two measures-proportion screened and frequency of screening by age, race/ethnicity, and hospital referral region. Fewer women were screened, but with similar frequency after 2009 for both age groups (after vs. before: age 65-74: 60.1% vs. 60.8% screened, 2.1 vs. 2.1 mammograms per screened woman; age 75 and older: 31.7% vs. 33.6% screened, 1.9 vs. 1.9 mammograms per screened woman; all p < 0.05). Black women were the only subgroup with an increase in screening use, and for both age groups (after vs. before: age 65-74: 55.4% vs. 54.0% screened and 2.0 vs. 1.9 mammograms per screened woman; age 75 and older: 28.5% vs. 27.9% screened and 1.8 vs. 1.8 mammograms per screened woman; all p < 0.05). Regional change patterns in screening were more similar between age groups (Pearson correlation r = 0.781 for proportion screened; r = 0.840 for frequency of screening) than between black versus nonblack women (Pearson correlation r = 0.221 for proportion screened; r = 0.212 for frequency of screening). Changes in screening mammography use for Medicare women are not fully aligned with the 2009 recommendations.

  2. Does mammogram attendance influence participation in cervical and colorectal cancer screening? A prospective study among 1856 French women.

    PubMed

    Bertaut, Aurélie; Coudert, Julien; Bengrine, Leila; Dancourt, Vincent; Binquet, Christine; Douvier, Serge

    2018-01-01

    We aimed to determine participation rates and factors associated with participation in colorectal (fecal occul blood test) and cervical cancer (Pap-smear) screening among a population of women participating in breast cancer screening. From August to October 2015, a self-administered questionnaire was sent by post to 2 900 women aged 50-65, living in Côte-d'Or, France, and who were up to date with mammogram screening. Polytomic logistic regression was used to identify correlates of participation in both cervical and colorectal cancer screenings. Participation in all 3 screenings was chosen as the reference. Study participation rate was 66.3% (n = 1856). Besides being compliant with mammogram, respectively 78.3% and 56.6% of respondents were up to date for cervical and colorectal cancer screenings, while 46.2% were compliant with the 3 screenings. Consultation with a gynecologist in the past year was associated with higher chance of undergoing the 3 screenings or female cancer screenings (p<10-4), when consultation with a GP was associated with higher chance of undergoing the 3 screenings or organized cancer screenings (p<0.05). Unemployment, obesity, age>59 and yearly flu vaccine were associated with a lower involvement in cervical cancer screening. Women from high socio-economic classes were more likely to attend only female cancer screenings (p = 0.009). Finally, a low level of physical activity and tobacco use were associated with higher risk of no additional screening participation (p<10-3 and p = 0.027). Among women participating in breast screening, colorectal and cervical cancer screening rates could be improved. Including communication about these 2 cancer screenings in the mammogram invitation could be worth to explore.

  3. Change in Mammography Use Following the Revised Guidelines from the U.S. Preventive Services Task Force.

    PubMed

    Lee, Jeannette Y; Malak, Sharp F; Klimberg, Vicki Suzanne; Henry-Tillman, Ronda; Kadlubar, Susan

    2017-03-01

    The U.S. Preventive Services Task Force (USPSTF) recommended screening mammography every 1-2 years for women 40 years and older in 2002, and changed its recommendations in 2009 to no routine screening for women between 40 and 49 years of age; and biennial screening for women between 50 and 74 years of age. This study evaluates the change in mammographic use after the issuance of the revised recommendations. Women who participated in a cross-sectional study of breast cancer risk factors from 2007 to 2013 were asked if they had received a mammogram in the preceding 2 years. All 3442 study participants who enrolled in the study after January 1, 2011 were matched by race, age, and educational level with women enrolled between 2007 and 2010. The proportions of women who stated they had received a mammogram in the past 2 years were compared between the two groups. One fourth of the participants were African American and 39% were 40-49 years of age. Among white women, significant decreases in recent mammogram use from 2007-2010 to 2011-2013 were detected for women 40-49 years of age (-10.3%, p < 0.001) and 50-74 years of age (-8.8%, p < 0.001). Among African-American women, the change in recent mammogram use was not statistically significant for women 40-49 years of age (-2.7%, p = 0.440) or 50-74 years of age (-2.2%, p = 0.398). Following the change in the USPSTF guidelines, mammography use among white women declined; however, no change was observed among African-American women. © 2016 Wiley Periodicals, Inc.

  4. Analysis of a mammography teaching program based on an affordance design model.

    PubMed

    Luo, Ping; Eikman, Edward A; Kealy, William; Qian, Wei

    2006-12-01

    The wide use of computer technology in education, particularly in mammogram reading, asks for e-learning evaluation. The existing media comparative studies, learner attitude evaluations, and performance tests are problematic. Based on an affordance design model, this study examined an existing e-learning program on mammogram reading. The selection criteria include content relatedness, representativeness, e-learning orientation, image quality, program completeness, and accessibility. A case study was conducted to examine the affordance features, functions, and presentations of the selected software. Data collection and analysis methods include interviews, protocol-based document analysis, and usability tests and inspection. Also some statistics were calculated. The examination of PBE identified that this educational software designed and programmed some tools. The learner can use these tools in the process of optimizing displays, scanning images, comparing different projections, marking the region of interests, constructing a descriptive report, assessing one's learning outcomes, and comparing one's decisions with the experts' decisions. Further, PBE provides some resources for the learner to construct one's knowledge and skills, including a categorized image library, a term-searching function, and some teaching links. Besides, users found it easy to navigate and carry out tasks. The users also reacted positively toward PBE's navigation system, instructional aids, layout, pace and flow of information, graphics, and other presentation design. The software provides learners with some cognitive tools, supporting their perceptual problem-solving processes and extending their capabilities. Learners can internalize the mental models in mammogram reading through multiple perceptual triangulations, sensitization of related features, semantic description of mammogram findings, and expert-guided semantic report construction. The design of these cognitive tools and the software interface matches the findings and principles in human learning and instructional design. Working with PBE's case-based simulations and categorized gallery, learners can enrich and transfer their experience to their jobs.

  5. Surveillance for cancer recurrence in long-term young breast cancer survivors randomly selected from a statewide cancer registry.

    PubMed

    Jones, Tarsha; Duquette, Debra; Underhill, Meghan; Ming, Chang; Mendelsohn-Victor, Kari E; Anderson, Beth; Milliron, Kara J; Copeland, Glenn; Janz, Nancy K; Northouse, Laurel L; Duffy, Sonia M; Merajver, Sofia D; Katapodi, Maria C

    2018-05-01

    This study examined clinical breast exam (CBE) and mammography surveillance in long-term young breast cancer survivors (YBCS) and identified barriers and facilitators to cancer surveillance practices. Data collected with a self-administered survey from a statewide, randomly selected sample of YBCS diagnosed with invasive breast cancer or ductal carcinoma in situ younger than 45 years old, stratified by race (Black vs. White/Other). Multivariate logistic regression models identified predictors of annual CBEs and mammograms. Among 859 YBCS (n = 340 Black; n = 519 White/Other; mean age = 51.0 ± 5.9; diagnosed 11.0 ± 4.0 years ago), the majority (> 85%) reported an annual CBE and a mammogram. Black YBCS in the study were more likely to report lower rates of annual mammography and more barriers accessing care compared to White/Other YBCS. Having a routine source of care, confidence to use healthcare services, perceived expectations from family members and healthcare providers to engage in cancer surveillance, and motivation to comply with these expectations were significant predictors of having annual CBEs and annual mammograms. Cost-related lack of access to care was a significant barrier to annual mammograms. Routine source of post-treatment care facilitated breast cancer surveillance above national average rates. Persistent disparities regarding access to mammography surveillance were identified for Black YBCS, primarily due to lack of access to routine source of care and high out-of-pocket costs. Public health action targeting cancer surveillance in YBCS should ensure routine source of post-treatment care and address cost-related barriers. Clinical Trials Registration Number: NCT01612338.

  6. Finding the minimal intervention needed for sustained mammography adherence.

    PubMed

    Gierisch, Jennifer M; DeFrank, Jessica T; Bowling, J Michael; Rimer, Barbara K; Matuszewski, Jeanine M; Farrell, David; Skinner, Celette Sugg

    2010-10-01

    Regular adherence to mammography screening saves lives, yet few women receive regular mammograms. RCT. Participants were recruited through a state employee health plan. All were women aged 40-75 years and had recent mammograms prior to enrollment (n=3547). Data were collected from 2004 to 2009. Trial tested efficacy of a two-step adaptively-designed intervention to increase mammography adherence over 4 years. The first intervention step consisted of three reminder types: enhanced usual care reminders (EUCR); enhanced letter reminders (ELR); both delivered by mail, and automated telephone reminders (ATR). After delivery of reminders, women who became off-schedule in any of the 4 years received a second step of supplemental interventions. Three supplemental intervention arms contained priming letters and telephone counseling: barriers only (BarriCall); barriers plus positive consequences of getting mammograms (BarriConCall+); and barriers plus negative consequences of not getting mammograms (BarriConCall-). Average cumulative number of days non-adherent to mammography over 4 years based on annual screening guidelines (analyses conducted in 2009). All reminders performed equally well in reducing number of days of non-adherence. Women randomized to receive supplemental interventions had significantly fewer days of non-adherence compared to women who received EUCR (p=0.0003). BarrConCall+ and BarrConCall- conditions did not significantly differ in days non-adherent compared to women in the barriers-only condition (BarriCon). The minimal intervention needed for sustained mammography use is a combination of a reminder followed by a priming letter and barrier-specific telephone counseling for women who become off-schedule. Additional costs associated with supplemental interventions should be considered by organizations deciding which interventions to use. NCT01148875. Copyright © 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Disparities in abnormal mammogram follow-up time for Asian women compared to non-Hispanic Whites and between Asian ethnic groups

    PubMed Central

    Nguyen, KH; Pasick, RJ; Stewart, SL; Kerlikowske, K; Karliner, LS

    2017-01-01

    Background Delays in abnormal mammogram follow-up contribute to poor outcomes. We examined abnormal screening mammogram follow-up differences for non-Hispanic Whites (NHW) and Asian women. Methods Prospective cohort of NHW and Asian women with a Breast Imaging Reporting and Data System abnormal result of 0 or 3+ in the San Francisco Mammography Registry between 2000–2010. We performed Kaplan-Meier estimation for median-days to follow-up with a diagnostic radiologic test, and compared proportion with follow-up at 30, 60 and 90 days, and no follow-up at one-year for Asians overall (and Asian ethnic groups) and NHWs. We additionally assessed the relationship between race/ethnicity and time-to-follow-up with adjusted Cox proportional hazards models. Results Among Asian women, Vietnamese and Filipinas had the longest, and Japanese the shortest, median follow-up time (32, 28, 19 days, respectively) compared to NHWs (15 days). The proportion of women receiving follow-up at 30 days was lower for Asians vs NHWs (57% vs 77%, p<0.0001), and these disparities persisted at 60 and 90 days for all Asian ethnic groups except Japanese. Asians had a reduced hazard of follow-up compared with NHWs (aHR 0.70, 95% CI 0.69–0.72). Asians also had a higher rate than NHWs of no follow-up (15% vs 10%; p<0.001); among Asian ethnic groups, Filipinas had the highest percentage of women with no follow-up (18.1%). Conclusion Asian, particularly Filipina and Vietnamese, women were less likely than NHWs to receive timely follow-up after an abnormal screening mammogram. Research should disaggregate Asian ethnicity to better understand and address barriers to effective cancer prevention. PMID:28603859

  8. Efficiency of Core Biopsy for BI-RADS-5 Breast Lesions.

    PubMed

    Wolf, Ronald; Quan, Glenda; Calhoun, Kris; Soot, Laurel; Skokan, Laurie

    2008-01-01

    Stereotactic biopsy has proven more cost effective for biopsy of lesions associated with moderately suspicious mammograms. Data regarding selection of stereotactic biopsy (CORE) instead of excisional biopsy (EB) as the first diagnostic procedure in patients with nonpalpable breast lesions and highest suspicion breast imaging-reporting and data system (BI-RADS)-5 mammograms are sparse. Records from a regional health system radiology database were screened for mammograms associated with image-guided biopsy. A total of 182 nonpalpable BI-RADS-5 lesions were sampled in 178 patients over 5 years, using CORE or EB. Initial surgical margins, number of surgeries, time from initial procedure to last related surgical procedure, and hospital and professional charges for related admissions were compared using chi-squared, t-test, and Wilcoxon Mann-Whitney tests. A total of 108 CORE and 74 EB were performed as the first diagnostic procedure. Invasive or in situ carcinoma was diagnosed in 156 (86%) of all biopsies, 95 in CORE and 61 in EB groups. Negative margins of the first surgical procedure were more frequent in CORE (n = 70, 74%) versus EB (n = 17, 28%), p < 0.05. Use of CORE was associated with fewer total surgical procedures per lesion (1.29 +/- 0.05 versus 1.8 +/- 0.05, p < 0.05). Time of initial diagnostic procedure to final treatment did not vary significantly according to group (27 +/- 2 days versus 22 +/- 2 days, CORE versus EB). Mean charges including the diagnostic procedure and all subsequent surgeries were not different between CORE and EB groups ($10,500 +/- 300 versus $11,500 +/- 500, p = 0.08). Use of CORE as the first procedure in patients with highly suspicious mammograms is associated with improved pathologic margins and need for fewer surgical procedures than EB, and should be considered the preferred initial diagnostic approach.

  9. Mobile Versus Fixed Facility: Latinas' Attitudes and Preferences for Obtaining a Mammogram.

    PubMed

    Scheel, John R; Tillack, Allison A; Mercer, Lauren; Coronado, Gloria D; Beresford, Shirley A A; Molina, Yamile; Thompson, Beti

    2018-01-01

    Mobile mammographic services have been proposed as a way to reduce Latinas' disproportionate late-stage presentation compared with white women by increasing their access to mammography. The aims of this study were to assess why Latinas may not use mobile mammographic services and to explore their preferences after using these services. Using a mixed-methods approach, a secondary analysis was conducted of baseline survey data (n = 538) from a randomized controlled trial to improve screening mammography rates among Latinas in Washington. Descriptive statistics and bivariate regression were used to characterize mammography location preferences and to test for associations with sociodemographic indices, health care access, and perceived breast cancer risk and beliefs. On the basis of these findings, a qualitative study (n = 18) was used to explore changes in perceptions after using mobile mammographic services. More Latinas preferred obtaining a mammogram at a fixed facility (52.3% [n = 276]) compared with having no preference (46.3% [n = 249]) and preferring mobile mammographic services (1.7% [n = 9]). Concerns about privacy and comfort (15.6% [n = 84]) and about general quality (10.6% [n = 57]) were common reasons for preferring a fixed facility. Those with no history of mammography preferred a fixed facility (P < .05). In the qualitative study, Latinas expressed similar initial concerns but became positive toward the mobile mammographic services after obtaining a mammogram. Although most Latinas preferred obtaining a mammogram at a fixed facility, positive experiences with mobile mammography services changed their attitudes toward them. These findings highlight the need to include community education when using mobile mammographic service to increase screening mammography rates in underserved communities. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Towards the use of computationally inserted lesions for mammographic CAD assessment

    NASA Astrophysics Data System (ADS)

    Ghanian, Zahra; Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2018-03-01

    Computer-aided detection (CADe) devices used for breast cancer detection on mammograms are typically first developed and assessed for a specific "original" acquisition system, e.g., a specific image detector. When CADe developers are ready to apply their CADe device to a new mammographic acquisition system, they typically assess the CADe device with images acquired using the new system. Collecting large repositories of clinical images containing verified cancer locations and acquired by the new image acquisition system is costly and time consuming. Our goal is to develop a methodology to reduce the clinical data burden in the assessment of a CADe device for use with a different image acquisition system. We are developing an image blending technique that allows users to seamlessly insert lesions imaged using an original acquisition system into normal images or regions acquired with a new system. In this study, we investigated the insertion of microcalcification clusters imaged using an original acquisition system into normal images acquired with that same system utilizing our previously-developed image blending technique. We first performed a reader study to assess whether experienced observers could distinguish between computationally inserted and native clusters. For this purpose, we applied our insertion technique to clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM) and the Breast Cancer Digital Repository (BCDR). Regions of interest containing microcalcification clusters from one breast of a patient were inserted into the contralateral breast of the same patient. The reader study included 55 native clusters and their 55 inserted counterparts. Analysis of the reader ratings using receiver operating characteristic (ROC) methodology indicated that inserted clusters cannot be reliably distinguished from native clusters (area under the ROC curve, AUC=0.58±0.04). Furthermore, CADe sensitivity was evaluated on mammograms with native and inserted microcalcification clusters using a commercial CADe system. For this purpose, we used full field digital mammograms (FFDMs) from 68 clinical cases, acquired at the University of Michigan Health System. The average sensitivities for native and inserted clusters were equal, 85.3% (58/68). These results demonstrate the feasibility of using the inserted microcalcification clusters for assessing mammographic CAD devices.

  11. HAlign-II: efficient ultra-large multiple sequence alignment and phylogenetic tree reconstruction with distributed and parallel computing.

    PubMed

    Wan, Shixiang; Zou, Quan

    2017-01-01

    Multiple sequence alignment (MSA) plays a key role in biological sequence analyses, especially in phylogenetic tree construction. Extreme increase in next-generation sequencing results in shortage of efficient ultra-large biological sequence alignment approaches for coping with different sequence types. Distributed and parallel computing represents a crucial technique for accelerating ultra-large (e.g. files more than 1 GB) sequence analyses. Based on HAlign and Spark distributed computing system, we implement a highly cost-efficient and time-efficient HAlign-II tool to address ultra-large multiple biological sequence alignment and phylogenetic tree construction. The experiments in the DNA and protein large scale data sets, which are more than 1GB files, showed that HAlign II could save time and space. It outperformed the current software tools. HAlign-II can efficiently carry out MSA and construct phylogenetic trees with ultra-large numbers of biological sequences. HAlign-II shows extremely high memory efficiency and scales well with increases in computing resource. THAlign-II provides a user-friendly web server based on our distributed computing infrastructure. HAlign-II with open-source codes and datasets was established at http://lab.malab.cn/soft/halign.

  12. Macroecology of unicellular organisms - patterns and processes.

    PubMed

    Soininen, Janne

    2012-02-01

    Macroecology examines the relationship between organisms and their environment at large spatial (and temporal) scales. Typically, macroecologists explain the large-scale patterns of abundance, distribution and diversity. Despite the difficulties in sampling and characterizing microbial diversity, macroecologists have recently also been interested in unicellular organisms. Here, I review the current advances made in microbial macroecology, as well as discuss related ecosystem functions. Overall, it seems that microorganisms suit surprisingly well to known species abundance distributions and show positive relationship between distribution and adundance. Microbial species-area and distance-decay relationships tend to be weaker than for macroorganisms, but nonetheless significant. Few findings on altitudinal gradients in unicellular taxa seem to differ greatly from corresponding findings for larger taxa, whereas latitudinal gradients among microorganisms have either been clearly evident or absent depending on the context. Literature also strongly emphasizes the role of spatial scale for the patterns of diversity and suggests that patterns are affected by species traits as well as ecosystem characteristics. Finally, I discuss the large role of local biotic and abiotic variables driving the community assembly in unicellular taxa and eventually dictating how multiple ecosystem processes are performed. Present review highlights the fact that most microorganisms may not differ fundamentally from larger taxa in their large-scale distribution patterns. Yet, review also shows that many aspects of microbial macroecology are still relatively poorly understood and specific patterns depend on focal taxa and ecosystem concerned. © 2011 Society for Applied Microbiology and Blackwell Publishing Ltd.

  13. Soil moisture and biogeochemical factors influence the distribution of annual Bromus species

    Treesearch

    Jayne Belnap; John M. Stark; Benjamin M. Rau; Edith B. Allen; Susan Phillips

    2016-01-01

    Abiotic factors have a strong influence on where annual Bromus species are found. At the large regional scale, temperature and precipitation extremes determine the boundaries of Bromus occurrence. At the more local scale, soil characteristics and climate influence distribution, cover, and performance. In hot, dry, summer-rainfall-dominated deserts (Sonoran, Chihuahuan...

  14. Convex hulls of random walks in higher dimensions: A large-deviation study

    NASA Astrophysics Data System (ADS)

    Schawe, Hendrik; Hartmann, Alexander K.; Majumdar, Satya N.

    2017-12-01

    The distribution of the hypervolume V and surface ∂ V of convex hulls of (multiple) random walks in higher dimensions are determined numerically, especially containing probabilities far smaller than P =10-1000 to estimate large deviation properties. For arbitrary dimensions and large walk lengths T , we suggest a scaling behavior of the distribution with the length of the walk T similar to the two-dimensional case and behavior of the distributions in the tails. We underpin both with numerical data in d =3 and d =4 dimensions. Further, we confirm the analytically known means of those distributions and calculate their variances for large T .

  15. Evaluation of Kirkwood-Buff integrals via finite size scaling: a large scale molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Dednam, W.; Botha, A. E.

    2015-01-01

    Solvation of bio-molecules in water is severely affected by the presence of co-solvent within the hydration shell of the solute structure. Furthermore, since solute molecules can range from small molecules, such as methane, to very large protein structures, it is imperative to understand the detailed structure-function relationship on the microscopic level. For example, it is useful know the conformational transitions that occur in protein structures. Although such an understanding can be obtained through large-scale molecular dynamic simulations, it is often the case that such simulations would require excessively large simulation times. In this context, Kirkwood-Buff theory, which connects the microscopic pair-wise molecular distributions to global thermodynamic properties, together with the recently developed technique, called finite size scaling, may provide a better method to reduce system sizes, and hence also the computational times. In this paper, we present molecular dynamics trial simulations of biologically relevant low-concentration solvents, solvated by aqueous co-solvent solutions. In particular we compare two different methods of calculating the relevant Kirkwood-Buff integrals. The first (traditional) method computes running integrals over the radial distribution functions, which must be obtained from large system-size NVT or NpT simulations. The second, newer method, employs finite size scaling to obtain the Kirkwood-Buff integrals directly by counting the particle number fluctuations in small, open sub-volumes embedded within a larger reservoir that can be well approximated by a much smaller simulation cell. In agreement with previous studies, which made a similar comparison for aqueous co-solvent solutions, without the additional solvent, we conclude that the finite size scaling method is also applicable to the present case, since it can produce computationally more efficient results which are equivalent to the more costly radial distribution function method.

  16. Expert identification of visual primitives used by CNNs during mammogram classification

    NASA Astrophysics Data System (ADS)

    Wu, Jimmy; Peck, Diondra; Hsieh, Scott; Dialani, Vandana; Lehman, Constance D.; Zhou, Bolei; Syrgkanis, Vasilis; Mackey, Lester; Patterson, Genevieve

    2018-02-01

    This work interprets the internal representations of deep neural networks trained for classification of diseased tissue in 2D mammograms. We propose an expert-in-the-loop inter- pretation method to label the behavior of internal units in convolutional neural networks (CNNs). Expert radiologists identify that the visual patterns detected by the units are correlated with meaningful medical phenomena such as mass tissue and calcificated vessels. We demonstrate that several trained CNN models are able to produce explanatory descriptions to support the final classification decisions. We view this as an important first step toward interpreting the internal representations of medical classification CNNs and explaining their predictions.

  17. Use of joint two-view information for computerized lesion detection on mammograms: improvement of microcalcification detection accuracy

    NASA Astrophysics Data System (ADS)

    Sahiner, Berkman; Gurcan, Metin N.; Chan, Heang-Ping; Hadjiiski, Lubomir M.; Petrick, Nicholas; Helvie, Mark A.

    2002-05-01

    We are developing new techniques to improve the accuracy of computerized microcalcification detection by using the joint two-view information on craniocaudal (CC) and mediolateral-oblique (MLO) views. After cluster candidates were detected using a single-view detection technique, candidates on CC and MLO views were paired using their radial distances from the nipple. Object pairs were classified with a joint two-view classifier that used the similarity of objects in a pair. Each cluster candidate was also classified as a true microcalcification cluster or a false-positive (FP) using its single-view features. The outputs of these two classifiers were fused. A data set of 38 pairs of mammograms from our database was used to train the new detection technique. The independent test set consisted of 77 pairs of mammograms from the University of South Florida public database. At a per-film sensitivity of 70%, the FP rates were 0.17 and 0.27 with the fusion and single-view detection methods, respectively. Our results indicate that correspondence of cluster candidates on two different views provides valuable additional information for distinguishing false from true microcalcification clusters.

  18. Associations Between Religion-Related Factors and Breast Cancer Screening Among American Muslims

    PubMed Central

    Padela, Aasim I.; Murrar, Sohad; Adviento, Brigid; Liao, Chuanhong; Hosseinian, Zahra; Peek, Monica; Curlin, Farr

    2015-01-01

    American Muslims have low rates of mammography utilization, and research suggests that religious values influence their health-seeking behaviors. We assessed associations between religion-related factors and breast cancer screening in this population. A diverse group of Muslim women were recruited from mosques and Muslim organization sites in Greater Chicago to self-administer a survey incorporating measures of fatalism, religiosity, discrimination, and Islamic modesty. 254 surveys were collected of which 240 met age inclusion criteria (40 years of age or older). Of the 240, 72 respondents were Arab, 71 South Asian, 59 African American, and 38 identified with another ethnicity. 77 % of respondents had at least one mammogram in their lifetime, yet 37 % had not obtained mammography within the past 2 years. In multivariate models, positive religious coping, and perceived religious discrimination in healthcare were negatively associated with having a mammogram in the past 2 years, while having a PCP was positively associated. Ever having a mammogram was positively associated with increasing age and years of US residency, and knowing someone with breast cancer. Promoting biennial mammography among American Muslims may require addressing ideas about religious coping and combating perceived religious discrimination through tailored interventions. PMID:24700026

  19. Associations between religion-related factors and breast cancer screening among American Muslims.

    PubMed

    Padela, Aasim I; Murrar, Sohad; Adviento, Brigid; Liao, Chuanhong; Hosseinian, Zahra; Peek, Monica; Curlin, Farr

    2015-06-01

    American Muslims have low rates of mammography utilization, and research suggests that religious values influence their health-seeking behaviors. We assessed associations between religion-related factors and breast cancer screening in this population. A diverse group of Muslim women were recruited from mosques and Muslim organization sites in Greater Chicago to self-administer a survey incorporating measures of fatalism, religiosity, discrimination, and Islamic modesty. 254 surveys were collected of which 240 met age inclusion criteria (40 years of age or older). Of the 240, 72 respondents were Arab, 71 South Asian, 59 African American, and 38 identified with another ethnicity. 77% of respondents had at least one mammogram in their lifetime, yet 37% had not obtained mammography within the past 2 years. In multivariate models, positive religious coping, and perceived religious discrimination in healthcare were negatively associated with having a mammogram in the past 2 years, while having a PCP was positively associated. Ever having a mammogram was positively associated with increasing age and years of US residency, and knowing someone with breast cancer. Promoting biennial mammography among American Muslims may require addressing ideas about religious coping and combating perceived religious discrimination through tailored interventions.

  20. A novel approach for detection and classification of mammographic microcalcifications using wavelet analysis and extreme learning machine.

    PubMed

    Malar, E; Kandaswamy, A; Chakravarthy, D; Giri Dharan, A

    2012-09-01

    The objective of this paper is to reveal the effectiveness of wavelet based tissue texture analysis for microcalcification detection in digitized mammograms using Extreme Learning Machine (ELM). Microcalcifications are tiny deposits of calcium in the breast tissue which are potential indicators for early detection of breast cancer. The dense nature of the breast tissue and the poor contrast of the mammogram image prohibit the effectiveness in identifying microcalcifications. Hence, a new approach to discriminate the microcalcifications from the normal tissue is done using wavelet features and is compared with different feature vectors extracted using Gray Level Spatial Dependence Matrix (GLSDM) and Gabor filter based techniques. A total of 120 Region of Interests (ROIs) extracted from 55 mammogram images of mini-Mias database, including normal and microcalcification images are used in the current research. The network is trained with the above mentioned features and the results denote that ELM produces relatively better classification accuracy (94%) with a significant reduction in training time than the other artificial neural networks like Bayesnet classifier, Naivebayes classifier, and Support Vector Machine. ELM also avoids problems like local minima, improper learning rate, and over fitting. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Mobile Phone Multilevel and Multimedia Messaging Intervention for Breast Cancer Screening: Pilot Randomized Controlled Trial.

    PubMed

    Lee, Hee; Ghebre, Rahel; Le, Chap; Jang, Yoo Jeong; Sharratt, Monica; Yee, Douglas

    2017-11-07

    Despite the increasing breast cancer incidence and mortality rates, Korean American immigrant women have one of the lowest rates of breast cancer screening across racial groups in the United States. Mobile health (mHealth), defined as the delivery of health care information or services through mobile communication devices, has been utilized to successfully improve a variety of health outcomes. This study adapted the principles of mHealth to advance breast cancer prevention efforts among Korean American immigrant women, an underserved community. Using a randomized controlled trial design, 120 Korean American women aged 40 to 77 years were recruited and randomly assigned to either the mMammogram intervention group (n=60) to receive culturally and personally tailored multilevel and multimedia messages through a mobile phone app along with health navigator services or the usual care control group (n=60) to receive a printed brochure. Outcome measures included knowledge, attitudes, and beliefs about breast cancer screening, readiness for mammography, and mammogram receipt. The feasibility and acceptability of the mMammogram intervention was also assessed. The intervention group showed significantly greater change on scores of knowledge of breast cancer and screening guidelines (P=.01). The intervention group also showed significantly greater readiness for mammography use after the intervention compared with the control group. A significantly higher proportion of women who received the mMammogram intervention (75%, 45/60) completed mammograms by the 6-month follow-up compared with the control group (30%, 18/60; P<.001). In addition, the intervention group rated satisfaction with the intervention (P=.003), effectiveness of the intervention (P<.001), and increase of knowledge on breast cancer and screenings (P=.001) significantly higher than the control group. A mobile phone app-based intervention combined with health navigator service was a feasible, acceptable, and effective intervention mechanism to promote breast cancer screening in Korean American immigrant women. A flexible, easily tailored approach that relies on recent technological advancements can reach underserved and hard-to-recruit populations that bear disproportionate cancer burdens. Clinicaltrials.gov NCT01972048; https://clinicaltrials.gov/show/NCT01972048 (Archived by WebCite at https://clinicaltrials.gov/archive/NCT01972048/2013_10_29). ©Hee Lee, Rahel Ghebre, Chap Le, Yoo Jeong Jang, Monica Sharratt, Douglas Yee. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 07.11.2017.

  2. Prospects of Detecting HI using Redshifted 21-cm Radiation at z˜3

    NASA Astrophysics Data System (ADS)

    Gehlot, Bharat Kumar; Bagla, J. S.

    2017-03-01

    Distribution of cold gas in the post-reionization era provides an important link between distribution of galaxies and the process of star formation. Redshifted 21-cm radiation from the hyperfine transition of neutral hydrogen allows us to probe the neutral component of cold gas, most of which is to be found in the interstellar medium of galaxies. Existing and upcoming radio telescopes can probe the large scale distribution of neutral hydrogen via HI intensity mapping. In this paper, we use an estimate of the HI power spectrum derived using an ansatz to compute the expected signal from the large scale HI distribution at z˜3. We find that the scale dependence of bias at small scales makes a significant difference to the expected signal even at large angular scales. We compare the predicted signal strength with the sensitivity of radio telescopes that can observe such radiation and calculate the observation time required for detecting neutral hydrogen at these redshifts. We find that OWFA (Ooty Wide Field Array) offers the best possibility to detect neutral hydrogen at z˜3 before the SKA (Square Kilometer Array) becomes operational. We find that the OWFA should be able to make a 3 σ or a more significant detection in 2000 hours of observations at several angular scales. Calculations done using the Fisher matrix approach indicate that a 5 σ detection of the binned HI power spectrum via measurement of the amplitude of the HI power spectrum is possible in 1000 h (Sarkar et al. 2017).

  3. Soil organic carbon - a large scale paired catchment assessment

    NASA Astrophysics Data System (ADS)

    Kunkel, V.; Hancock, G. R.; Wells, T.

    2016-12-01

    Soil organic carbon (SOC) concentration can vary both spatially and temporally driven by differences in soil properties, topography and climate. However most studies have focused on point scale data sets with a paucity of studies examining larger scale catchments. Here we examine the spatial and temporal distribution of SOC for two large catchments. The Krui (575 km2) and Merriwa River (675km2) catchments (New South Wales, Australia). Both have similar shape, soils, topography and orientation. We show that SOC distribution is very similar for both catchments and that elevation (and associated increase in soil moisture) is a major influence on SOC. We also show that there is little change in SOC from the initial assessment in 2006 to 2015 despite a major drought from 2003 to 2010 and extreme rainfall events in 2007 and 2010 -therefore SOC concentration appears robust. However, we found significant relationships between erosion and deposition patterns (as quantified using 137Cs) and SOC for both catchments again demonstrating a strong geomorphic relationship. Vegetation across the catchments was assessed using remote sensing (Landsat and MODIS). Vegetation patterns were temporally consistent with above ground biomass increasing with elevation. SOC could be predicted using both these low and high resolution remote sensing platforms. Results indicate that, although moderate resolution (250 m) allows for reasonable prediction of the spatial distribution of SOC, the higher resolution (30 m) improved the strength of the SOC-NDVI relationship. The relationship between SOC and 137Cs, as a surrogate for the erosion and deposition of SOC, suggested that sediment transport and deposition influences the distribution of SOC within the catchment. The findings demonstrate that over the large catchment scale and at the decadal time scale that SOC is relatively constant and can largely be predicted by topography.

  4. Reader strategies: variability and error- methodology, findings, and health policy implications from a study of the U.S. population of mammographers

    NASA Astrophysics Data System (ADS)

    Beam, Craig A.

    2002-04-01

    Each year, approximately 60% of all US women over the age of 40 utilize mammography. Through the matrix of an imaging technology, this Population of Patients (POP) interacts with a population of approximately 20,000 physicians who interpret mammograms in the US. This latter Population of Diagnosticians (POD) operationally serves as the interface between an image-centric healthcare technology system and patient. Methods: using data collected from a large POD and POP based study, I evaluate the distribution of several ROC curve-related parameters in the POD and explore the health policy implications of a population ROC curve for mammography. Results and Conclusions: Principal Components Analysis suggests that two Binormal parameters are sufficient to explain variation in the POD and implies that the Binormal model is foundational to Health Policy Research in Mammography. A population ROC curve based on percentiles of the POD can be used to set targets to achieve national health policy goals. Medical Image Perception science provides the framework. Alternatively, a restrictive policy can be envisioned using performance criteria based on area. However, the data suggests this sort of policy would be too costly in terms of reduced healthcare service capacity in the US in the face of burgeoning demands.

  5. A Census of Large-scale (≥10 PC), Velocity-coherent, Dense Filaments in the Northern Galactic Plane: Automated Identification Using Minimum Spanning Tree

    NASA Astrophysics Data System (ADS)

    Wang, Ke; Testi, Leonardo; Burkert, Andreas; Walmsley, C. Malcolm; Beuther, Henrik; Henning, Thomas

    2016-09-01

    Large-scale gaseous filaments with lengths up to the order of 100 pc are on the upper end of the filamentary hierarchy of the Galactic interstellar medium (ISM). Their association with respect to the Galactic structure and their role in Galactic star formation are of great interest from both an observational and theoretical point of view. Previous “by-eye” searches, combined together, have started to uncover the Galactic distribution of large filaments, yet inherent bias and small sample size limit conclusive statistical results from being drawn. Here, we present (1) a new, automated method for identifying large-scale velocity-coherent dense filaments, and (2) the first statistics and the Galactic distribution of these filaments. We use a customized minimum spanning tree algorithm to identify filaments by connecting voxels in the position-position-velocity space, using the Bolocam Galactic Plane Survey spectroscopic catalog. In the range of 7\\buildrel{\\circ}\\over{.} 5≤slant l≤slant 194^\\circ , we have identified 54 large-scale filaments and derived mass (˜ {10}3{--}{10}5 {M}⊙ ), length (10-276 pc), linear mass density (54-8625 {M}⊙ pc-1), aspect ratio, linearity, velocity gradient, temperature, fragmentation, Galactic location, and orientation angle. The filaments concentrate along major spiral arms. They are widely distributed across the Galactic disk, with 50% located within ±20 pc from the Galactic mid-plane and 27% run in the center of spiral arms. An order of 1% of the molecular ISM is confined in large filaments. Massive star formation is more favorable in large filaments compared to elsewhere. This is the first comprehensive catalog of large filaments that can be useful for a quantitative comparison with spiral structures and numerical simulations.

  6. Exploring the role of movement in determining the global distribution of marine biomass using a coupled hydrodynamic - Size-based ecosystem model

    NASA Astrophysics Data System (ADS)

    Watson, James R.; Stock, Charles A.; Sarmiento, Jorge L.

    2015-11-01

    Modeling the dynamics of marine populations at a global scale - from phytoplankton to fish - is necessary if we are to quantify how climate change and other broad-scale anthropogenic actions affect the supply of marine-based food. Here, we estimate the abundance and distribution of fish biomass using a simple size-based food web model coupled to simulations of global ocean physics and biogeochemistry. We focus on the spatial distribution of biomass, identifying highly productive regions - shelf seas, western boundary currents and major upwelling zones. In the absence of fishing, we estimate the total ocean fish biomass to be ∼ 2.84 ×109 tonnes, similar to previous estimates. However, this value is sensitive to the choice of parameters, and further, allowing fish to move had a profound impact on the spatial distribution of fish biomass and the structure of marine communities. In particular, when movement is implemented the viable range of large predators is greatly increased, and stunted biomass spectra characterizing large ocean regions in simulations without movement, are replaced with expanded spectra that include large predators. These results highlight the importance of considering movement in global-scale ecological models.

  7. The impact of land-surface wetness heterogeneity on mesoscale heat fluxes

    NASA Technical Reports Server (NTRS)

    Chen, Fei; Avissar, Roni

    1994-01-01

    Vertical heat fluxes associated with mesoscale circulations generated by land-surface wetness discontinuities are often stronger than turbulent fluxes, especially in the upper part of the atmospheric planetary boundary layer. As a result, they contribute significantly to the subgrid-scale fluxes in large-scale atmospheric models. Yet they are not considered in these models. To provide some insights into the possible parameterization of these fluxes in large-scale models, a state-of-the-art mesoscale numerical model was used to investigate the relationships between mesoscale heat fluxes and atmospheric and land-surface characteristics that play a key role in the generation of mesoscale circulations. The distribution of land-surface wetness, the wavenumber and the wavelength of the land-surface discontinuities, and the large-scale wind speed have a significant impact on the mesoscale heat fluxes. Empirical functions were derived to characterize the relationships between mesoscale heat fluxes and the spatial distribution of land-surface wetness. The strongest mesoscale heat fluxes were obtained for a wavelength of forcing corresponding approximately to the local Rossby deformation radius. The mesoscale heat fluxes are weakened by large-scale background winds but remain significant even with moderate winds.

  8. Distributed weighted least-squares estimation with fast convergence for large-scale systems.

    PubMed

    Marelli, Damián Edgardo; Fu, Minyue

    2015-01-01

    In this paper we study a distributed weighted least-squares estimation problem for a large-scale system consisting of a network of interconnected sub-systems. Each sub-system is concerned with a subset of the unknown parameters and has a measurement linear in the unknown parameters with additive noise. The distributed estimation task is for each sub-system to compute the globally optimal estimate of its own parameters using its own measurement and information shared with the network through neighborhood communication. We first provide a fully distributed iterative algorithm to asymptotically compute the global optimal estimate. The convergence rate of the algorithm will be maximized using a scaling parameter and a preconditioning method. This algorithm works for a general network. For a network without loops, we also provide a different iterative algorithm to compute the global optimal estimate which converges in a finite number of steps. We include numerical experiments to illustrate the performances of the proposed methods.

  9. Distributed weighted least-squares estimation with fast convergence for large-scale systems☆

    PubMed Central

    Marelli, Damián Edgardo; Fu, Minyue

    2015-01-01

    In this paper we study a distributed weighted least-squares estimation problem for a large-scale system consisting of a network of interconnected sub-systems. Each sub-system is concerned with a subset of the unknown parameters and has a measurement linear in the unknown parameters with additive noise. The distributed estimation task is for each sub-system to compute the globally optimal estimate of its own parameters using its own measurement and information shared with the network through neighborhood communication. We first provide a fully distributed iterative algorithm to asymptotically compute the global optimal estimate. The convergence rate of the algorithm will be maximized using a scaling parameter and a preconditioning method. This algorithm works for a general network. For a network without loops, we also provide a different iterative algorithm to compute the global optimal estimate which converges in a finite number of steps. We include numerical experiments to illustrate the performances of the proposed methods. PMID:25641976

  10. Climate-driven C4 plant distributions in China: divergence in C4 taxa

    PubMed Central

    Wang, Renzhong; Ma, Linna

    2016-01-01

    There have been debates on the driving factors of C4 plant expansion, such as PCO2 decline in the late Micocene and warmer climate and precipitation at large-scale modern ecosystems. These disputes are mainly due to the lack of direct evidence and extensive data analysis. Here we use mass flora data to explore the driving factors of C4 distribution and divergent patterns for different C4 taxa at continental scale in China. The results display that it is mean annual climate variables driving C4 distribution at present-day vegetation. Mean annual temperature is the critical restriction of total C4 plants and the precipitation gradients seem to have much less impact. Grass and sedge C4 plants are largely restricted to mean annual temperature and precipitation respectively, while Chenopod C4 plants are strongly restricted by aridity in China. Separate regression analysis can succeed to detect divergences of climate distribution patterns of C4 taxa at global scale. PMID:27302686

  11. Incorporating linguistic knowledge for learning distributed word representations.

    PubMed

    Wang, Yan; Liu, Zhiyuan; Sun, Maosong

    2015-01-01

    Combined with neural language models, distributed word representations achieve significant advantages in computational linguistics and text mining. Most existing models estimate distributed word vectors from large-scale data in an unsupervised fashion, which, however, do not take rich linguistic knowledge into consideration. Linguistic knowledge can be represented as either link-based knowledge or preference-based knowledge, and we propose knowledge regularized word representation models (KRWR) to incorporate these prior knowledge for learning distributed word representations. Experiment results demonstrate that our estimated word representation achieves better performance in task of semantic relatedness ranking. This indicates that our methods can efficiently encode both prior knowledge from knowledge bases and statistical knowledge from large-scale text corpora into a unified word representation model, which will benefit many tasks in text mining.

  12. Incorporating Linguistic Knowledge for Learning Distributed Word Representations

    PubMed Central

    Wang, Yan; Liu, Zhiyuan; Sun, Maosong

    2015-01-01

    Combined with neural language models, distributed word representations achieve significant advantages in computational linguistics and text mining. Most existing models estimate distributed word vectors from large-scale data in an unsupervised fashion, which, however, do not take rich linguistic knowledge into consideration. Linguistic knowledge can be represented as either link-based knowledge or preference-based knowledge, and we propose knowledge regularized word representation models (KRWR) to incorporate these prior knowledge for learning distributed word representations. Experiment results demonstrate that our estimated word representation achieves better performance in task of semantic relatedness ranking. This indicates that our methods can efficiently encode both prior knowledge from knowledge bases and statistical knowledge from large-scale text corpora into a unified word representation model, which will benefit many tasks in text mining. PMID:25874581

  13. Modeling Booklet Effects for Nonequivalent Group Designs in Large-Scale Assessment

    ERIC Educational Resources Information Center

    Hecht, Martin; Weirich, Sebastian; Siegle, Thilo; Frey, Andreas

    2015-01-01

    Multiple matrix designs are commonly used in large-scale assessments to distribute test items to students. These designs comprise several booklets, each containing a subset of the complete item pool. Besides reducing the test burden of individual students, using various booklets allows aligning the difficulty of the presented items to the assumed…

  14. An Alternative Way to Model Population Ability Distributions in Large-Scale Educational Surveys

    ERIC Educational Resources Information Center

    Wetzel, Eunike; Xu, Xueli; von Davier, Matthias

    2015-01-01

    In large-scale educational surveys, a latent regression model is used to compensate for the shortage of cognitive information. Conventionally, the covariates in the latent regression model are principal components extracted from background data. This operational method has several important disadvantages, such as the handling of missing data and…

  15. Finite Mixture Multilevel Multidimensional Ordinal IRT Models for Large Scale Cross-Cultural Research

    ERIC Educational Resources Information Center

    de Jong, Martijn G.; Steenkamp, Jan-Benedict E. M.

    2010-01-01

    We present a class of finite mixture multilevel multidimensional ordinal IRT models for large scale cross-cultural research. Our model is proposed for confirmatory research settings. Our prior for item parameters is a mixture distribution to accommodate situations where different groups of countries have different measurement operations, while…

  16. Upper Washita River experimental watersheds: Multiyear stability of soil water content profiles

    USDA-ARS?s Scientific Manuscript database

    Scaling in situ soil water content time series data to a large spatial domain is a key element of watershed environmental monitoring and modeling. The primary method of estimating and monitoring large-scale soil water content distributions is via in situ networks. It is critical to establish the s...

  17. Patterns of Spatial Variation of Assemblages Associated with Intertidal Rocky Shores: A Global Perspective

    PubMed Central

    Cruz-Motta, Juan José; Miloslavich, Patricia; Palomo, Gabriela; Iken, Katrin; Konar, Brenda; Pohle, Gerhard; Trott, Tom; Benedetti-Cecchi, Lisandro; Herrera, César; Hernández, Alejandra; Sardi, Adriana; Bueno, Andrea; Castillo, Julio; Klein, Eduardo; Guerra-Castro, Edlin; Gobin, Judith; Gómez, Diana Isabel; Riosmena-Rodríguez, Rafael; Mead, Angela; Bigatti, Gregorio; Knowlton, Ann; Shirayama, Yoshihisa

    2010-01-01

    Assemblages associated with intertidal rocky shores were examined for large scale distribution patterns with specific emphasis on identifying latitudinal trends of species richness and taxonomic distinctiveness. Seventy-two sites distributed around the globe were evaluated following the standardized sampling protocol of the Census of Marine Life NaGISA project (www.nagisa.coml.org). There were no clear patterns of standardized estimators of species richness along latitudinal gradients or among Large Marine Ecosystems (LMEs); however, a strong latitudinal gradient in taxonomic composition (i.e., proportion of different taxonomic groups in a given sample) was observed. Environmental variables related to natural influences were strongly related to the distribution patterns of the assemblages on the LME scale, particularly photoperiod, sea surface temperature (SST) and rainfall. In contrast, no environmental variables directly associated with human influences (with the exception of the inorganic pollution index) were related to assemblage patterns among LMEs. Correlations of the natural assemblages with either latitudinal gradients or environmental variables were equally strong suggesting that neither neutral models nor models based solely on environmental variables sufficiently explain spatial variation of these assemblages at a global scale. Despite the data shortcomings in this study (e.g., unbalanced sample distribution), we show the importance of generating biological global databases for the use in large-scale diversity comparisons of rocky intertidal assemblages to stimulate continued sampling and analyses. PMID:21179546

  18. Spectral fingerprints of large-scale neuronal interactions.

    PubMed

    Siegel, Markus; Donner, Tobias H; Engel, Andreas K

    2012-01-11

    Cognition results from interactions among functionally specialized but widely distributed brain regions; however, neuroscience has so far largely focused on characterizing the function of individual brain regions and neurons therein. Here we discuss recent studies that have instead investigated the interactions between brain regions during cognitive processes by assessing correlations between neuronal oscillations in different regions of the primate cerebral cortex. These studies have opened a new window onto the large-scale circuit mechanisms underlying sensorimotor decision-making and top-down attention. We propose that frequency-specific neuronal correlations in large-scale cortical networks may be 'fingerprints' of canonical neuronal computations underlying cognitive processes.

  19. Radiological and clinical features of adult non-puerperal mastitis.

    PubMed

    Tan, H; Li, R; Peng, W; Liu, H; Gu, Y; Shen, X

    2013-04-01

    To describe the radiological and clinical features of adult non-puerperal mastitis and to determine the most accurate method of preventing unnecessary surgical procedures. Clinical and imaging findings were retrospectively reviewed in 51 females with non-puerperal mastitis, which was confirmed by biopsy/surgical pathology. All 51 patients had pre-operative MRI; 45 patients also had sonograms and 25 also had mammograms, pre-operatively. Of the 51 cases with non-puerperal mastitis, 94.1% (48/51) were confirmed as having acute or chronic inflammation, and the other 3 had plasma cell mastitis; areola papillaris inflammation was found in 39.2% (20/51) of the cases. Overall, 6 of the 25 cases that were examined with mammography and 2 of the 45 cases that were examined with sonography appeared normal, but all 51 lesions were positively identified on MRI. Asymmetrical density (12/25) on mammograms and solitary or separated/contiguous, clustered, hypoechoic mass-like lesions (31/45) on ultrasound were the most common signs of non-puerperal mastitis. On enhanced MRI, 90.2% (46/51) of patients showed non-mass-like enhanced lesions. Multiple regional enhancements in the pattern of distribution (32/46) and separated or contiguous, clustered, rim-like enhancements in the pattern of internal enhancement (29/46) were the most common manifestations in non-mass-like enhanced lesions. Of the 51 patients, mastitis Type 1 and Type 2 in the time-signal intensity curve were detected in 47.1% and 51.0% of the patients, respectively. The breast imaging reporting and data system categories with the highest number of patients were Category 0 (9/25) on mammography, Category 4a on sonography (18/45) and Category 4a on MRI (29/51). The findings from mammography and ultrasound are non-specific; therefore, using MR can be helpful in the diagnosis, especially in the presence of non-mass-like enhancements that are multiple, regional, separated, or contiguous, clustered and rim-like. Mastitis is often neglected because of the lack of typical clinical signs and symptoms. This study has assessed and described the clinical features and imaging findings of adult non-puerperal mastitis on mammograms, sonograms and MRI and found that MRI is more specific in the diagnosis of disease.

  20. Radiological and clinical features of adult non-puerperal mastitis

    PubMed Central

    Tan, H; Li, R; Liu, H; Gu, Y; Shen, X

    2013-01-01

    Objective: To describe the radiological and clinical features of adult non-puerperal mastitis and to determine the most accurate method of preventing unnecessary surgical procedures. Methods: Clinical and imaging findings were retrospectively reviewed in 51 females with non-puerperal mastitis, which was confirmed by biopsy/surgical pathology. All 51 patients had pre-operative MRI; 45 patients also had sonograms and 25 also had mammograms, pre-operatively. Results: Of the 51 cases with non-puerperal mastitis, 94.1% (48/51) were confirmed as having acute or chronic inflammation, and the other 3 had plasma cell mastitis; areola papillaris inflammation was found in 39.2% (20/51) of the cases. Overall, 6 of the 25 cases that were examined with mammography and 2 of the 45 cases that were examined with sonography appeared normal, but all 51 lesions were positively identified on MRI. Asymmetrical density (12/25) on mammograms and solitary or separated/contiguous, clustered, hypoechoic mass-like lesions (31/45) on ultrasound were the most common signs of non-puerperal mastitis. On enhanced MRI, 90.2% (46/51) of patients showed non-mass-like enhanced lesions. Multiple regional enhancements in the pattern of distribution (32/46) and separated or contiguous, clustered, rim-like enhancements in the pattern of internal enhancement (29/46) were the most common manifestations in non-mass-like enhanced lesions. Of the 51 patients, mastitis Type 1 and Type 2 in the time–signal intensity curve were detected in 47.1% and 51.0% of the patients, respectively. The breast imaging reporting and data system categories with the highest number of patients were Category 0 (9/25) on mammography, Category 4a on sonography (18/45) and Category 4a on MRI (29/51). Conclusion: The findings from mammography and ultrasound are non-specific; therefore, using MR can be helpful in the diagnosis, especially in the presence of non-mass-like enhancements that are multiple, regional, separated, or contiguous, clustered and rim-like. Advances in knowledge: Mastitis is often neglected because of the lack of typical clinical signs and symptoms. This study has assessed and described the clinical features and imaging findings of adult non-puerperal mastitis on mammograms, sonograms and MRI and found that MRI is more specific in the diagnosis of disease. PMID:23392197

  1. SCALE PROBLEMS IN REPORTING LANDSCAPE PATTERN AT THE REGIONAL SCALE

    EPA Science Inventory

    Remotely sensed data for Southeastern United States (Standard Federal Region 4) are used to examine the scale problems involved in reporting landscape pattern for a large, heterogeneous region. Frequency distributions of landscape indices illustrate problems associated with the g...

  2. Large- and small-scale environmental factors drive distributions of cool-adapted plants in karstic microrefugia

    PubMed Central

    Vojtkó, András; Farkas, Tünde; Szabó, Anna; Havadtői, Krisztina; Vojtkó, Anna E.; Tölgyesi, Csaba; Cseh, Viktória; Erdős, László; Maák, István Elek; Keppel, Gunnar

    2017-01-01

    Background and aims Dolines are small- to large-sized bowl-shaped depressions of karst surfaces. They may constitute important microrefugia, as thermal inversion often maintains cooler conditions within them. This study aimed to identify the effects of large- (macroclimate) and small-scale (slope aspect and vegetation type) environmental factors on cool-adapted plants in karst dolines of East-Central Europe. We also evaluated the potential of these dolines to be microrefugia that mitigate the effects of climate change on cool-adapted plants in both forest and grassland ecosystems. Methods We compared surveys of plant species composition that were made between 2007 and 2015 in 21 dolines distributed across four mountain ranges (sites) in Hungary and Romania. We examined the effects of environmental factors on the distribution and number of cool-adapted plants on three scales: (1) regional (all sites); (2) within sites and; (3) within dolines. Generalized linear models and non-parametric tests were used for the analyses. Key Results Macroclimate, vegetation type and aspect were all significant predictors of the diversity of cool-adapted plants. More cool-adapted plants were recorded in the coolest site, with only few found in the warmest site. At the warmest site, the distribution of cool-adapted plants was restricted to the deepest parts of dolines. Within sites of intermediate temperature and humidity, the effect of vegetation type and aspect on the diversity of cool-adapted plants was often significant, with more taxa being found in grasslands (versus forests) and on north-facing slopes (versus south-facing slopes). Conclusions There is large variation in the number and spatial distribution of cool-adapted plants in karst dolines, which is related to large- and small-scale environmental factors. Both macro- and microrefugia are therefore likely to play important roles in facilitating the persistence of cool-adapted plants under global warming. PMID:28025290

  3. Large- and small-scale environmental factors drive distributions of cool-adapted plants in karstic microrefugia.

    PubMed

    Bátori, Zoltán; Vojtkó, András; Farkas, Tünde; Szabó, Anna; Havadtői, Krisztina; Vojtkó, Anna E; Tölgyesi, Csaba; Cseh, Viktória; Erdős, László; Maák, István Elek; Keppel, Gunnar

    2017-01-01

    Dolines are small- to large-sized bowl-shaped depressions of karst surfaces. They may constitute important microrefugia, as thermal inversion often maintains cooler conditions within them. This study aimed to identify the effects of large- (macroclimate) and small-scale (slope aspect and vegetation type) environmental factors on cool-adapted plants in karst dolines of East-Central Europe. We also evaluated the potential of these dolines to be microrefugia that mitigate the effects of climate change on cool-adapted plants in both forest and grassland ecosystems. We compared surveys of plant species composition that were made between 2007 and 2015 in 21 dolines distributed across four mountain ranges (sites) in Hungary and Romania. We examined the effects of environmental factors on the distribution and number of cool-adapted plants on three scales: (1) regional (all sites); (2) within sites and; (3) within dolines. Generalized linear models and non-parametric tests were used for the analyses. Macroclimate, vegetation type and aspect were all significant predictors of the diversity of cool-adapted plants. More cool-adapted plants were recorded in the coolest site, with only few found in the warmest site. At the warmest site, the distribution of cool-adapted plants was restricted to the deepest parts of dolines. Within sites of intermediate temperature and humidity, the effect of vegetation type and aspect on the diversity of cool-adapted plants was often significant, with more taxa being found in grasslands (versus forests) and on north-facing slopes (versus south-facing slopes). There is large variation in the number and spatial distribution of cool-adapted plants in karst dolines, which is related to large- and small-scale environmental factors. Both macro- and microrefugia are therefore likely to play important roles in facilitating the persistence of cool-adapted plants under global warming. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Domain-Adapted Convolutional Networks for Satellite Image Classification: A Large-Scale Interactive Learning Workflow

    DOE PAGES

    Lunga, Dalton D.; Yang, Hsiuhan Lexie; Reith, Andrew E.; ...

    2018-02-06

    Satellite imagery often exhibits large spatial extent areas that encompass object classes with considerable variability. This often limits large-scale model generalization with machine learning algorithms. Notably, acquisition conditions, including dates, sensor position, lighting condition, and sensor types, often translate into class distribution shifts introducing complex nonlinear factors and hamper the potential impact of machine learning classifiers. Here, this article investigates the challenge of exploiting satellite images using convolutional neural networks (CNN) for settlement classification where the class distribution shifts are significant. We present a large-scale human settlement mapping workflow based-off multiple modules to adapt a pretrained CNN to address themore » negative impact of distribution shift on classification performance. To extend a locally trained classifier onto large spatial extents areas we introduce several submodules: First, a human-in-the-loop element for relabeling of misclassified target domain samples to generate representative examples for model adaptation; second, an efficient hashing module to minimize redundancy and noisy samples from the mass-selected examples; and third, a novel relevance ranking module to minimize the dominance of source example on the target domain. The workflow presents a novel and practical approach to achieve large-scale domain adaptation with binary classifiers that are based-off CNN features. Experimental evaluations are conducted on areas of interest that encompass various image characteristics, including multisensors, multitemporal, and multiangular conditions. Domain adaptation is assessed on source–target pairs through the transfer loss and transfer ratio metrics to illustrate the utility of the workflow.« less

  5. Domain-Adapted Convolutional Networks for Satellite Image Classification: A Large-Scale Interactive Learning Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lunga, Dalton D.; Yang, Hsiuhan Lexie; Reith, Andrew E.

    Satellite imagery often exhibits large spatial extent areas that encompass object classes with considerable variability. This often limits large-scale model generalization with machine learning algorithms. Notably, acquisition conditions, including dates, sensor position, lighting condition, and sensor types, often translate into class distribution shifts introducing complex nonlinear factors and hamper the potential impact of machine learning classifiers. Here, this article investigates the challenge of exploiting satellite images using convolutional neural networks (CNN) for settlement classification where the class distribution shifts are significant. We present a large-scale human settlement mapping workflow based-off multiple modules to adapt a pretrained CNN to address themore » negative impact of distribution shift on classification performance. To extend a locally trained classifier onto large spatial extents areas we introduce several submodules: First, a human-in-the-loop element for relabeling of misclassified target domain samples to generate representative examples for model adaptation; second, an efficient hashing module to minimize redundancy and noisy samples from the mass-selected examples; and third, a novel relevance ranking module to minimize the dominance of source example on the target domain. The workflow presents a novel and practical approach to achieve large-scale domain adaptation with binary classifiers that are based-off CNN features. Experimental evaluations are conducted on areas of interest that encompass various image characteristics, including multisensors, multitemporal, and multiangular conditions. Domain adaptation is assessed on source–target pairs through the transfer loss and transfer ratio metrics to illustrate the utility of the workflow.« less

  6. PKI security in large-scale healthcare networks.

    PubMed

    Mantas, Georgios; Lymberopoulos, Dimitrios; Komninos, Nikos

    2012-06-01

    During the past few years a lot of PKI (Public Key Infrastructures) infrastructures have been proposed for healthcare networks in order to ensure secure communication services and exchange of data among healthcare professionals. However, there is a plethora of challenges in these healthcare PKI infrastructures. Especially, there are a lot of challenges for PKI infrastructures deployed over large-scale healthcare networks. In this paper, we propose a PKI infrastructure to ensure security in a large-scale Internet-based healthcare network connecting a wide spectrum of healthcare units geographically distributed within a wide region. Furthermore, the proposed PKI infrastructure facilitates the trust issues that arise in a large-scale healthcare network including multi-domain PKI infrastructures.

  7. Spatio-temporal precipitation climatology over complex terrain using a censored additive regression model.

    PubMed

    Stauffer, Reto; Mayr, Georg J; Messner, Jakob W; Umlauf, Nikolaus; Zeileis, Achim

    2017-06-15

    Flexible spatio-temporal models are widely used to create reliable and accurate estimates for precipitation climatologies. Most models are based on square root transformed monthly or annual means, where a normal distribution seems to be appropriate. This assumption becomes invalid on a daily time scale as the observations involve large fractions of zero observations and are limited to non-negative values. We develop a novel spatio-temporal model to estimate the full climatological distribution of precipitation on a daily time scale over complex terrain using a left-censored normal distribution. The results demonstrate that the new method is able to account for the non-normal distribution and the large fraction of zero observations. The new climatology provides the full climatological distribution on a very high spatial and temporal resolution, and is competitive with, or even outperforms existing methods, even for arbitrary locations.

  8. Overview of Sea-Ice Properties, Distribution and Temporal Variations, for Application to Ice-Atmosphere Chemical Processes.

    NASA Astrophysics Data System (ADS)

    Moritz, R. E.

    2005-12-01

    The properties, distribution and temporal variation of sea-ice are reviewed for application to problems of ice-atmosphere chemical processes. Typical vertical structure of sea-ice is presented for different ice types, including young ice, first-year ice and multi-year ice, emphasizing factors relevant to surface chemistry and gas exchange. Time average annual cycles of large scale variables are presented, including ice concentration, ice extent, ice thickness and ice age. Spatial and temporal variability of these large scale quantities is considered on time scales of 1-50 years, emphasizing recent and projected changes in the Arctic pack ice. The amount and time evolution of open water and thin ice are important factors that influence ocean-ice-atmosphere chemical processes. Observations and modeling of the sea-ice thickness distribution function are presented to characterize the range of variability in open water and thin ice.

  9. Point-Focusing Solar-Power Distributed Receivers

    NASA Technical Reports Server (NTRS)

    Lucas, J. W.

    1985-01-01

    Two-volume annual report describes development work aimed at achieving large-scale production of modular, point-focusing distributed receivers (PFDR's) for solar-powered generation of electricity or thermal power for industrial use.

  10. Drought forecasting in Luanhe River basin involving climatic indices

    NASA Astrophysics Data System (ADS)

    Ren, Weinan; Wang, Yixuan; Li, Jianzhu; Feng, Ping; Smith, Ronald J.

    2017-11-01

    Drought is regarded as one of the most severe natural disasters globally. This is especially the case in Tianjin City, Northern China, where drought can affect economic development and people's livelihoods. Drought forecasting, the basis of drought management, is an important mitigation strategy. In this paper, we evolve a probabilistic forecasting model, which forecasts transition probabilities from a current Standardized Precipitation Index (SPI) value to a future SPI class, based on conditional distribution of multivariate normal distribution to involve two large-scale climatic indices at the same time, and apply the forecasting model to 26 rain gauges in the Luanhe River basin in North China. The establishment of the model and the derivation of the SPI are based on the hypothesis of aggregated monthly precipitation that is normally distributed. Pearson correlation and Shapiro-Wilk normality tests are used to select appropriate SPI time scale and large-scale climatic indices. Findings indicated that longer-term aggregated monthly precipitation, in general, was more likely to be considered normally distributed and forecasting models should be applied to each gauge, respectively, rather than to the whole basin. Taking Liying Gauge as an example, we illustrate the impact of the SPI time scale and lead time on transition probabilities. Then, the controlled climatic indices of every gauge are selected by Pearson correlation test and the multivariate normality of SPI, corresponding climatic indices for current month and SPI 1, 2, and 3 months later are demonstrated using Shapiro-Wilk normality test. Subsequently, we illustrate the impact of large-scale oceanic-atmospheric circulation patterns on transition probabilities. Finally, we use a score method to evaluate and compare the performance of the three forecasting models and compare them with two traditional models which forecast transition probabilities from a current to a future SPI class. The results show that the three proposed models outperform the two traditional models and involving large-scale climatic indices can improve the forecasting accuracy.

  11. Cosmic void clumps

    NASA Astrophysics Data System (ADS)

    Lares, M.; Luparello, H. E.; Garcia Lambas, D.; Ruiz, A. N.; Ceccarelli, L.; Paz, D.

    2017-10-01

    Cosmic voids are of great interest given their relation to the large scale distribution of mass and the way they trace cosmic flows shaping the cosmic web. Here we show that the distribution of voids has, in consonance with the distribution of mass, a characteristic scale at which void pairs are preferentially located. We identify clumps of voids with similar environments and use them to define second order underdensities. Also, we characterize its properties and analyze its impact on the cosmic microwave background.

  12. Descriptive Statistics for Modern Test Score Distributions: Skewness, Kurtosis, Discreteness, and Ceiling Effects.

    PubMed

    Ho, Andrew D; Yu, Carol C

    2015-06-01

    Many statistical analyses benefit from the assumption that unconditional or conditional distributions are continuous and normal. More than 50 years ago in this journal, Lord and Cook chronicled departures from normality in educational tests, and Micerri similarly showed that the normality assumption is met rarely in educational and psychological practice. In this article, the authors extend these previous analyses to state-level educational test score distributions that are an increasingly common target of high-stakes analysis and interpretation. Among 504 scale-score and raw-score distributions from state testing programs from recent years, nonnormal distributions are common and are often associated with particular state programs. The authors explain how scaling procedures from item response theory lead to nonnormal distributions as well as unusual patterns of discreteness. The authors recommend that distributional descriptive statistics be calculated routinely to inform model selection for large-scale test score data, and they illustrate consequences of nonnormality using sensitivity studies that compare baseline results to those from normalized score scales.

  13. A 14 h-3 Gpc3 study of cosmic homogeneity using BOSS DR12 quasar sample

    NASA Astrophysics Data System (ADS)

    Laurent, Pierre; Le Goff, Jean-Marc; Burtin, Etienne; Hamilton, Jean-Christophe; Hogg, David W.; Myers, Adam; Ntelis, Pierros; Pâris, Isabelle; Rich, James; Aubourg, Eric; Bautista, Julian; Delubac, Timothée; du Mas des Bourboux, Hélion; Eftekharzadeh, Sarah; Palanque Delabrouille, Nathalie; Petitjean, Patrick; Rossi, Graziano; Schneider, Donald P.; Yeche, Christophe

    2016-11-01

    The BOSS quasar sample is used to study cosmic homogeneity with a 3D survey in the redshift range 2.2 < z < 2.8. We measure the count-in-sphere, N(< r), i.e. the average number of objects around a given object, and its logarithmic derivative, the fractal correlation dimension, D2(r). For a homogeneous distribution N(< r) propto r3 and D2(r) = 3. Due to the uncertainty on tracer density evolution, 3D surveys can only probe homogeneity up to a redshift dependence, i.e. they probe so-called ``spatial isotropy". Our data demonstrate spatial isotropy of the quasar distribution in the redshift range 2.2 < z < 2.8 in a model-independent way, independent of any FLRW fiducial cosmology, resulting in 3 - langleD2rangle < 1.7 × 10-3 (2 σ) over the range 250 < r < 1200 h-1 Mpc for the quasar distribution. If we assume that quasars do not have a bias much less than unity, this implies spatial isotropy of the matter distribution on large scales. Then, combining with the Copernican principle, we finally get homogeneity of the matter distribution on large scales. Alternatively, using a flat ΛCDM fiducial cosmology with CMB-derived parameters, and measuring the quasar bias relative to this ΛCDM model, our data provide a consistency check of the model, in terms of how homogeneous the Universe is on different scales. D2(r) is found to be compatible with our ΛCDM model on the whole 10 < r < 1200 h-1 Mpc range. For the matter distribution we obtain 3 - langleD2rangle < 5 × 10-5 (2 σ) over the range 250 < r < 1200 h-1 Mpc, consistent with homogeneity on large scales.

  14. Pre-reading mammograms by specialised breast technologists: legal implications for technologist and radiologist in The Netherlands.

    PubMed

    van den Biggelaar, F J H M; Flobbe, K; van Engelshoven, J M A; de Bijl, N P Y M

    2009-09-01

    This paper focuses on the legal implications in terms of duties and responsibilities for radiologists and radiologic technologists of independent pre-reading of mammograms by radiologic technologists, so patients could be discharged without being seen by a radiologist. Pre-reading could be effectuated when preconditions are met to perform reserved procedures by unauthorised professionals as stated in the Individual Health Care Professions (IHCP) Act. Furthermore, compliance with a protocol or code of conduct in combination with adequate training and supervision should be sufficient to disprove potential claims. For a wide implementation, pre-reading should be well-embedded in legal rules and should answer the professional standard of care.

  15. Radiogenomics analysis identifies correlations of digital mammography with clinical molecular signatures in breast cancer.

    PubMed

    Tamez-Peña, Jose-Gerardo; Rodriguez-Rojas, Juan-Andrés; Gomez-Rueda, Hugo; Celaya-Padilla, Jose-Maria; Rivera-Prieto, Roxana-Alicia; Palacios-Corona, Rebeca; Garza-Montemayor, Margarita; Cardona-Huerta, Servando; Treviño, Victor

    2018-01-01

    In breast cancer, well-known gene expression subtypes have been related to a specific clinical outcome. However, their impact on the breast tissue phenotype has been poorly studied. Here, we investigate the association of imaging data of tumors to gene expression signatures from 71 patients with breast cancer that underwent pre-treatment digital mammograms and tumor biopsies. From digital mammograms, a semi-automated radiogenomics analysis generated 1,078 features describing the shape, signal distribution, and texture of tumors along their contralateral image used as control. From tumor biopsy, we estimated the OncotypeDX and PAM50 recurrence scores using gene expression microarrays. Then, we used multivariate analysis under stringent cross-validation to train models predicting recurrence scores. Few univariate features reached Spearman correlation coefficients above 0.4. Nevertheless, multivariate analysis yielded significantly correlated models for both signatures (correlation of OncotypeDX = 0.49 ± 0.07 and PAM50 = 0.32 ± 0.10 in stringent cross-validation and OncotypeDX = 0.83 and PAM50 = 0.78 for a unique model). Equivalent models trained from the unaffected contralateral breast were not correlated suggesting that the image signatures were tumor-specific and that overfitting was not a considerable issue. We also noted that models were improved by combining clinical information (triple negative status and progesterone receptor). The models used mostly wavelets and fractal features suggesting their importance to capture tumor information. Our results suggest that molecular-based recurrence risk and breast cancer subtypes have observable radiographic phenotypes. To our knowledge, this is the first study associating mammographic information to gene expression recurrence signatures.

  16. Radiogenomics analysis identifies correlations of digital mammography with clinical molecular signatures in breast cancer

    PubMed Central

    Tamez-Peña, Jose-Gerardo; Rodriguez-Rojas, Juan-Andrés; Gomez-Rueda, Hugo; Celaya-Padilla, Jose-Maria; Rivera-Prieto, Roxana-Alicia; Palacios-Corona, Rebeca; Garza-Montemayor, Margarita; Cardona-Huerta, Servando

    2018-01-01

    In breast cancer, well-known gene expression subtypes have been related to a specific clinical outcome. However, their impact on the breast tissue phenotype has been poorly studied. Here, we investigate the association of imaging data of tumors to gene expression signatures from 71 patients with breast cancer that underwent pre-treatment digital mammograms and tumor biopsies. From digital mammograms, a semi-automated radiogenomics analysis generated 1,078 features describing the shape, signal distribution, and texture of tumors along their contralateral image used as control. From tumor biopsy, we estimated the OncotypeDX and PAM50 recurrence scores using gene expression microarrays. Then, we used multivariate analysis under stringent cross-validation to train models predicting recurrence scores. Few univariate features reached Spearman correlation coefficients above 0.4. Nevertheless, multivariate analysis yielded significantly correlated models for both signatures (correlation of OncotypeDX = 0.49 ± 0.07 and PAM50 = 0.32 ± 0.10 in stringent cross-validation and OncotypeDX = 0.83 and PAM50 = 0.78 for a unique model). Equivalent models trained from the unaffected contralateral breast were not correlated suggesting that the image signatures were tumor-specific and that overfitting was not a considerable issue. We also noted that models were improved by combining clinical information (triple negative status and progesterone receptor). The models used mostly wavelets and fractal features suggesting their importance to capture tumor information. Our results suggest that molecular-based recurrence risk and breast cancer subtypes have observable radiographic phenotypes. To our knowledge, this is the first study associating mammographic information to gene expression recurrence signatures. PMID:29596496

  17. Network-scale spatial and temporal variation in Chinook salmon (Oncorhynchus tshawytscha) redd distributions: patterns inferred from spatially continuous replicate surveys

    Treesearch

    Daniel J. Isaak; Russell F. Thurow

    2006-01-01

    Spatially continuous sampling designs, when temporally replicated, provide analytical flexibility and are unmatched in their ability to provide a dynamic system view. We have compiled such a data set by georeferencing the network-scale distribution of Chinook salmon (Oncorhynchus tshawytscha) redds across a large wilderness basin (7330 km2) in...

  18. [Spatial point pattern analysis of main trees and flowering Fargesia qinlingensis in Abies fargesii forests in Mt Taibai of the Qinling Mountains, China].

    PubMed

    Li, Guo Chun; Song, Hua Dong; Li, Qi; Bu, Shu Hai

    2017-11-01

    In Abies fargesii forests of the giant panda's habitats in Mt. Taibai, the spatial distribution patterns and interspecific associations of main tree species and their spatial associations with the understory flowering Fargesia qinlingensis were analyzed at multiple scales by univariate and bivaria-te O-ring function in point pattern analysis. The results showed that in the A. fargesii forest, the number of A. fargesii was largest but its population structure was in decline. The population of Betula platyphylla was relatively young, with a stable population structure, while the population of B. albo-sinensis declined. The three populations showed aggregated distributions at small scales and gradually showed random distributions with increasing spatial scales. Spatial associations among tree species were mainly showed at small scales and gradually became not spatially associated with increasing scale. A. fargesii and B. platyphylla were positively associated with flowering F. qinlingensis at large and medium scales, whereas B. albo-sinensis showed negatively associated with flowering F. qinlingensis at large and medium scales. The interaction between trees and F. qinlingensis in the habitats of giant panda promoted the dynamic succession and development of forests, which changed the environment of giant panda's habitats in Qinling.

  19. Scaling laws of passive-scalar diffusion in the interstellar medium

    NASA Astrophysics Data System (ADS)

    Colbrook, Matthew J.; Ma, Xiangcheng; Hopkins, Philip F.; Squire, Jonathan

    2017-05-01

    Passive-scalar mixing (metals, molecules, etc.) in the turbulent interstellar medium (ISM) is critical for abundance patterns of stars and clusters, galaxy and star formation, and cooling from the circumgalactic medium. However, the fundamental scaling laws remain poorly understood in the highly supersonic, magnetized, shearing regime relevant for the ISM. We therefore study the full scaling laws governing passive-scalar transport in idealized simulations of supersonic turbulence. Using simple phenomenological arguments for the variation of diffusivity with scale based on Richardson diffusion, we propose a simple fractional diffusion equation to describe the turbulent advection of an initial passive scalar distribution. These predictions agree well with the measurements from simulations, and vary with turbulent Mach number in the expected manner, remaining valid even in the presence of a large-scale shear flow (e.g. rotation in a galactic disc). The evolution of the scalar distribution is not the same as obtained using simple, constant 'effective diffusivity' as in Smagorinsky models, because the scale dependence of turbulent transport means an initially Gaussian distribution quickly develops highly non-Gaussian tails. We also emphasize that these are mean scalings that apply only to ensemble behaviours (assuming many different, random scalar injection sites): individual Lagrangian 'patches' remain coherent (poorly mixed) and simply advect for a large number of turbulent flow-crossing times.

  20. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    PubMed

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Constraints on the Origin of Cosmic Rays above 1018 eV from Large-scale Anisotropy Searches in Data of the Pierre Auger Observatory

    NASA Astrophysics Data System (ADS)

    Pierre Auger Collaboration; Abreu, P.; Aglietta, M.; Ahlers, M.; Ahn, E. J.; Albuquerque, I. F. M.; Allard, D.; Allekotte, I.; Allen, J.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Alves Batista, R.; Ambrosio, M.; Aminaei, A.; Anchordoqui, L.; Andringa, S.; Antiči'c, T.; Aramo, C.; Arganda, E.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avenier, M.; Avila, G.; Badescu, A. M.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Bardenet, R.; Barroso, S. L. C.; Baughman, B.; Bäuml, J.; Baus, C.; Beatty, J. J.; Becker, K. H.; Bellétoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanco, F.; Blanco, M.; Bleve, C.; Blümer, H.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brancus, I.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Buroker, L.; Burton, R. E.; Caballero-Mora, K. S.; Caccianiga, B.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Cheng, S. H.; Chiavassa, A.; Chinellato, J. A.; Chirinos Diaz, J.; Chudoba, J.; Cilmo, M.; Clay, R. W.; Cocciolo, G.; Collica, L.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daniel, B.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; del Peral, L.; del Río, M.; Deligny, O.; Dembinski, H.; Dhital, N.; Di Giulio, C.; Díaz Castro, M. L.; Diep, P. N.; Diogo, F.; Dobrigkeit, C.; Docters, W.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Espadanal, J.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Fang, K.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferguson, A. P.; Fick, B.; Figueira, J. M.; Filevich, A.; Filipčič, A.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Fratu, O.; Fröhlich, U.; Fuchs, B.; Gaior, R.; Gamarra, R. F.; Gambetta, S.; García, B.; Garcia Roca, S. T.; Garcia-Gamez, D.; Garcia-Pinto, D.; Garilli, G.; Gascon Bravo, A.; Gemmeke, H.; Ghia, P. L.; Giller, M.; Gitto, J.; Glass, H.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gómez Berisso, M.; Gómez Vitale, P. F.; Gonçalves, P.; Gonzalez, J. G.; Gookin, B.; Gorgi, A.; Gouffon, P.; Grashorn, E.; Grebe, S.; Griffith, N.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hansen, P.; Harari, D.; Harrison, T. A.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hill, G. C.; Hojvat, C.; Hollon, N.; Holmes, V. C.; Homola, P.; Hörandel, J. R.; Horvath, P.; Hrabovský, M.; Huber, D.; Huege, T.; Insolia, A.; Ionita, F.; Italiano, A.; Jansen, S.; Jarne, C.; Jiraskova, S.; Josebachuili, M.; Kadija, K.; Kampert, K. H.; Karhan, P.; Kasper, P.; Katkov, I.; Kégl, B.; Keilhauer, B.; Keivani, A.; Kelley, J. L.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapp, J.; Koang, D.-H.; Kotera, K.; Krohm, N.; Krömer, O.; Kruppke-Hansen, D.; Kuempel, D.; Kulbartz, J. K.; Kunka, N.; La Rosa, G.; Lachaud, C.; LaHurd, D.; Latronico, L.; Lauer, R.; Lautridou, P.; Le Coz, S.; Leão, M. S. A. B.; Lebrun, D.; Lebrun, P.; Leigui de Oliveira, M. A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; López, R.; Lopez Agüera, A.; Louedec, K.; Lozano Bahilo, J.; Lu, L.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Maller, J.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, J.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martin, L.; Martinez, H.; Martínez Bravo, O.; Martraire, D.; Masías Meza, J. J.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurel, D.; Maurizio, D.; Mazur, P. O.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Mertsch, P.; Messina, S.; Meurer, C.; Meyhandan, R.; Mi'canovi'c, S.; Micheletti, M. I.; Minaya, I. A.; Miramonti, L.; Molina-Bueno, L.; Mollerach, S.; Monasor, M.; Monnier Ragaigne, D.; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Mostafá, M.; Moura, C. A.; Muller, M. A.; Müller, G.; Münchmeyer, M.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nelles, A.; Neuser, J.; Nhung, P. T.; Niechciol, M.; Niemietz, L.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nožka, L.; Oehlschläger, J.; Olinto, A.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parra, A.; Pastor, S.; Paul, T.; Pech, M.; Peķala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrolini, A.; Petrov, Y.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Plum, M.; Ponce, V. H.; Pontz, M.; Porcelli, A.; Privitera, P.; Prouza, M.; Quel, E. J.; Querchfeld, S.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Revenu, B.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Rivera, H.; Rizi, V.; Roberts, J.; Rodrigues de Carvalho, W.; Rodriguez, G.; Rodriguez Cabo, I.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodríguez-Frías, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouillé-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Rühle, C.; Saftoiu, A.; Salamida, F.; Salazar, H.; Salesa Greus, F.; Salina, G.; Sánchez, F.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, B.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovánek, P.; Schröder, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Sigl, G.; Silva Lopez, H. H.; Sima, O.; 'Smiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Srivastava, Y. N.; Stanic, S.; Stapleton, J.; Stasielak, J.; Stephan, M.; Stutz, A.; Suarez, F.; Suomijärvi, T.; Supanitsky, A. D.; Šuša, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Szuba, M.; Tapia, A.; Tartare, M.; Taşcău, O.; Tcaciuc, R.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Todero Peixoto, C. J.; Toma, G.; Tomankova, L.; Tomé, B.; Tonachini, A.; Torralba Elipe, G.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van Aar, G.; van den Berg, A. M.; van Velzen, S.; van Vliet, A.; Varela, E.; Vargas Cárdenas, B.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Verzi, V.; Vicha, J.; Videla, M.; Villaseñor, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Walz, D.; Watson, A. A.; Weber, M.; Weidenhaupt, K.; Weindl, A.; Werner, F.; Westerhoff, S.; Whelan, B. J.; Widom, A.; Wieczorek, G.; Wiencke, L.; Wilczyńska, B.; Wilczyński, H.; Will, M.; Williams, C.; Winchen, T.; Wommer, M.; Wundheiler, B.; Yamamoto, T.; Yapici, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zamorano Garcia, B.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Zhou, J.; Zhu, Y.; Zimbres Silva, M.; Ziolkowski, M.

    2013-01-01

    A thorough search for large-scale anisotropies in the distribution of arrival directions of cosmic rays detected above 1018 eV at the Pierre Auger Observatory is reported. For the first time, these large-scale anisotropy searches are performed as a function of both the right ascension and the declination and expressed in terms of dipole and quadrupole moments. Within the systematic uncertainties, no significant deviation from isotropy is revealed. Upper limits on dipole and quadrupole amplitudes are derived under the hypothesis that any cosmic ray anisotropy is dominated by such moments in this energy range. These upper limits provide constraints on the production of cosmic rays above 1018 eV, since they allow us to challenge an origin from stationary galactic sources densely distributed in the galactic disk and emitting predominantly light particles in all directions.

  2. [A bomb attack in the Netherlands; how would we provide hospital care?

    PubMed

    Haverkort, J J M; de Jong, M B; van Spengler, L L; Leenen, L P H

    2017-01-01

    - There is an ever-present threat of large-scale incidents and disasters, such as terrorism and natural disasters.- Preparation and planning are the key to successful response to major incidents and disasters, which is why education, training sessions and exercises take place in the Netherlands.- Analysis of recent large-scale incidents in Europe and the USA emphasises the importance of adequate distribution of the wounded to centres where the correct care can be provided.- A major step has been taken in the Netherlands to provide for such an eventuality with the introduction of distribution plans for the wounded, and other initiatives such as a regional hospital disaster plan.- If a large-scale incident should take place the Netherlands also has a Major Incident Hospital at its disposal; this is a unique facility that can guarantee availability of 200 spare beds to the Netherlands healthcare system within 30 minutes.

  3. Large-scale quantum networks based on graphs

    NASA Astrophysics Data System (ADS)

    Epping, Michael; Kampermann, Hermann; Bruß, Dagmar

    2016-05-01

    Society relies and depends increasingly on information exchange and communication. In the quantum world, security and privacy is a built-in feature for information processing. The essential ingredient for exploiting these quantum advantages is the resource of entanglement, which can be shared between two or more parties. The distribution of entanglement over large distances constitutes a key challenge for current research and development. Due to losses of the transmitted quantum particles, which typically scale exponentially with the distance, intermediate quantum repeater stations are needed. Here we show how to generalise the quantum repeater concept to the multipartite case, by describing large-scale quantum networks, i.e. network nodes and their long-distance links, consistently in the language of graphs and graph states. This unifying approach comprises both the distribution of multipartite entanglement across the network, and the protection against errors via encoding. The correspondence to graph states also provides a tool for optimising the architecture of quantum networks.

  4. Contribution of peculiar shear motions to large-scale structure

    NASA Technical Reports Server (NTRS)

    Mueler, Hans-Reinhard; Treumann, Rudolf A.

    1994-01-01

    Self-gravitating shear flow instability simulations in a cold dark matter-dominated expanding Einstein-de Sitter universe have been performed. When the shear flow speed exceeds a certain threshold, self-gravitating Kelvin-Helmoholtz instability occurs, forming density voids and excesses along the shear flow layer which serve as seeds for large-scale structure formation. A possible mechanism for generating shear peculiar motions are velocity fluctuations induced by the density perturbations of the postinflation era. In this scenario, short scales grow earlier than large scales. A model of this kind may contribute to the cellular structure of the luminous mass distribution in the universe.

  5. Bilateral Image Subtraction and Multivariate Models for the Automated Triaging of Screening Mammograms

    PubMed Central

    Celaya-Padilla, José; Martinez-Torteya, Antonio; Rodriguez-Rojas, Juan; Galvan-Tejada, Jorge; Treviño, Victor; Tamez-Peña, José

    2015-01-01

    Mammography is the most common and effective breast cancer screening test. However, the rate of positive findings is very low, making the radiologic interpretation monotonous and biased toward errors. This work presents a computer-aided diagnosis (CADx) method aimed to automatically triage mammogram sets. The method coregisters the left and right mammograms, extracts image features, and classifies the subjects into risk of having malignant calcifications (CS), malignant masses (MS), and healthy subject (HS). In this study, 449 subjects (197 CS, 207 MS, and 45 HS) from a public database were used to train and evaluate the CADx. Percentile-rank (p-rank) and z-normalizations were used. For the p-rank, the CS versus HS model achieved a cross-validation accuracy of 0.797 with an area under the receiver operating characteristic curve (AUC) of 0.882; the MS versus HS model obtained an accuracy of 0.772 and an AUC of 0.842. For the z-normalization, the CS versus HS model achieved an accuracy of 0.825 with an AUC of 0.882 and the MS versus HS model obtained an accuracy of 0.698 and an AUC of 0.807. The proposed method has the potential to rank cases with high probability of malignant findings aiding in the prioritization of radiologists work list. PMID:26240818

  6. The Efficacy of Mammography Boot Camp to Improve the Performance of Radiologists

    PubMed Central

    Lee, Eun Hye; Jung, Seung Eun; Kim, You Me; Choi, Nami

    2014-01-01

    Objective To evaluate the efficacy of a mammography boot camp (MBC) to improve radiologists' performance in interpreting mammograms in the National Cancer Screening Program (NCSP) in Korea. Materials and Methods Between January and July of 2013, 141 radiologists were invited to a 3-day educational program composed of lectures and group practice readings using 250 digital mammography cases. The radiologists' performance in interpreting mammograms were evaluated using a pre- and post-camp test set of 25 cases validated prior to the camp by experienced breast radiologists. Factors affecting the radiologists' performance, including age, type of attending institution, and type of test set cases, were analyzed. Results The average scores of the pre- and post-camp tests were 56.0 ± 12.2 and 78.3 ± 9.2, respectively (p < 0.001). The post-camp test scores were higher than the pre-camp test scores for all age groups and all types of attending institutions (p < 0.001). The rate of incorrect answers in the post-camp test decreased compared to the pre-camp test for all suspicious cases, but not for negative cases (p > 0.05). Conclusion The MBC improves radiologists' performance in interpreting mammograms irrespective of age and type of attending institution. Improved interpretation is observed for suspicious cases, but not for negative cases. PMID:25246818

  7. Promoting Breast Cancer Screening through Storytelling by Chamorro Cancer Survivors

    PubMed Central

    Manglona, Rosa Duenas; Robert, Suzanne; Isaacson, Lucy San Nicolas; Garrido, Marie; Henrich, Faye Babauta; Santos, Lola Sablan; Le, Daisy; Peters, Ruth

    2017-01-01

    The largest Chamorro population outside of Guam and the Mariana Islands reside in California. Cancer health disparities disproportionally affect Pacific Islander communities, including the Chamorro, and breast cancer is the most common cancer affecting women. To address health concerns such as cancer, Pacific Islander women frequently utilize storytelling to initiate conversations about health and to address sensitive topics such as breast health and cancer. One form of storytelling used in San Diego is a play that conveys the message of breast cancer screening to the community in a culturally and linguistically appropriate way. This play, Nan Nena’s Mammogram, tells the story of an older woman in the community who learns about breast cancer screening from her young niece. The story builds upon the underpinnings of Chamorro culture - family, community, support, and humor - to portray discussing breast health, getting support for breast screening, and visiting the doctor. The story of Nan Nena’s Mammogram reflects the willingness of a few pioneering Chamorro women to use their personal experiences of cancer survivorship to promote screening for others. Through the support of a Chamorro community-based organization, these Chamorro breast cancer survivors have used the success of Nan Nena’s Mammogram to expand their education activities and to form a new cancer survivor organization for Chamorro women in San Diego. PMID:29805328

  8. Consistency of visual assessments of mammographic breast density from vendor-specific "for presentation" images.

    PubMed

    Abdolell, Mohamed; Tsuruda, Kaitlyn; Lightfoot, Christopher B; Barkova, Eva; McQuaid, Melanie; Caines, Judy; Iles, Sian E

    2016-01-01

    Discussions of percent breast density (PD) and breast cancer risk implicitly assume that visual assessments of PD are comparable between vendors despite differences in technology and display algorithms. This study examines the extent to which visual assessments of PD differ between mammograms acquired from two vendors. Pairs of "for presentation" digital mammography images were obtained from two mammography units for 146 women who had a screening mammogram on one vendor unit followed by a diagnostic mammogram on a different vendor unit. Four radiologists independently visually assessed PD from single left mediolateral oblique view images from the two vendors. Analysis of variance, intra-class correlation coefficients (ICC), scatter plots, and Bland-Altman plots were used to evaluate PD assessments between vendors. The mean radiologist PD for each image was used as a consensus PD measure. Overall agreement of the PD assessments was excellent between the two vendors with an ICC of 0.95 (95% confidence interval: 0.93 to 0.97). Bland-Altman plots demonstrated narrow upper and lower limits of agreement between the vendors with only a small bias (2.3 percentage points). The results of this study support the assumption that visual assessment of PD is consistent across mammography vendors despite vendor-specific appearances of "for presentation" images.

  9. Investigating the Link Between Radiologists Gaze, Diagnostic Decision, and Image Content

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tourassi, Georgia; Voisin, Sophie; Paquit, Vincent C

    2013-01-01

    Objective: To investigate machine learning for linking image content, human perception, cognition, and error in the diagnostic interpretation of mammograms. Methods: Gaze data and diagnostic decisions were collected from six radiologists who reviewed 20 screening mammograms while wearing a head-mounted eye-tracker. Texture analysis was performed in mammographic regions that attracted radiologists attention and in all abnormal regions. Machine learning algorithms were investigated to develop predictive models that link: (i) image content with gaze, (ii) image content and gaze with cognition, and (iii) image content, gaze, and cognition with diagnostic error. Both group-based and individualized models were explored. Results: By poolingmore » the data from all radiologists machine learning produced highly accurate predictive models linking image content, gaze, cognition, and error. Merging radiologists gaze metrics and cognitive opinions with computer-extracted image features identified 59% of the radiologists diagnostic errors while confirming 96.2% of their correct diagnoses. The radiologists individual errors could be adequately predicted by modeling the behavior of their peers. However, personalized tuning appears to be beneficial in many cases to capture more accurately individual behavior. Conclusions: Machine learning algorithms combining image features with radiologists gaze data and diagnostic decisions can be effectively developed to recognize cognitive and perceptual errors associated with the diagnostic interpretation of mammograms.« less

  10. A situational analysis of breast cancer early detection services in Trinidad and Tobago.

    PubMed

    Badal, Kimberly; Rampersad, Fidel; Warner, Wayne A; Toriola, Adetunji T; Mohammed, Hamish; Scheffel, Harold-Alexis; Ali, Rehanna; Moosoodeen, Murrie; Konduru, Siva; Russel, Adaila; Haraksingh, Rajini

    2018-01-01

    A situational analysis of breast cancer (BC) early detection services was carried out to investigate whether Trinidad and Tobago (T&T) has the framework for successful organized national screening. An online survey was designed to assess the availability, accessibility, quality control and assurance (QC&A), and monitoring and evaluation (M&E) mechanisms for public and private BC early detection. A focus group with local radiologists (n = 3) was held to identify unaddressed challenges and make recommendations for improvement. Major public hospitals offer free detection services with wait times of 1-6 months for an appointment. Private institutions offer mammograms for TTD$240 (USD$37) at minimum with same day service. Both sectors report a lack of trained staff. Using 1.2 mammograms per 10,000 women ≥40 years as sufficient, the public sector's rate of 0.19 mammograms per 10,000 women ≥40 years for screening and diagnosis is inadequate. Program M&E mechanisms, QC&A guidelines for machinery use, delays in receipt of pathology reports, and unreliable drug access are further unaddressed challenges. T&T must first strengthen its human and physical resources, implement M&E and QC&A measures, strengthen cancer care, and address other impediments to BC early detection before investing in nationally organized BC screening.

  11. Automated recognition of microcalcification clusters in mammograms

    NASA Astrophysics Data System (ADS)

    Bankman, Isaac N.; Christens-Barry, William A.; Kim, Dong W.; Weinberg, Irving N.; Gatewood, Olga B.; Brody, William R.

    1993-07-01

    The widespread and increasing use of mammographic screening for early breast cancer detection is placing a significant strain on clinical radiologists. Large numbers of radiographic films have to be visually interpreted in fine detail to determine the subtle hallmarks of cancer that may be present. We developed an algorithm for detecting microcalcification clusters, the most common and useful signs of early, potentially curable breast cancer. We describe this algorithm, which utilizes contour map representations of digitized mammographic films, and discuss its benefits in overcoming difficulties often encountered in algorithmic approaches to radiographic image processing. We present experimental analyses of mammographic films employing this contour-based algorithm and discuss practical issues relevant to its use in an automated film interpretation instrument.

  12. Performance characteristics of digital vs film screen mammography in community practice.

    PubMed

    Dabbous, Firas; Dolecek, Therese A; Friedewald, Sarah M; Tossas-Milligan, Katherine Y; Macarol, Tere; Summerfelt, Wm Thomas; Rauscher, Garth H

    2018-05-01

    We compared the performance characteristics of 297 629 full field digital (FFDM) and 416 791 screen film mammograms (SFM). Sensitivity increased with age, decreased with breast density, and was lower for more aggressive and lobular tumors. While sensitivity did not differ significantly by modality, specificity was generally 1%-2% points higher for FFDM than for SFM across age and breast density categories. The lower recall rate for FFDM vs SFM in our study may partially explain performance differences by modality. In this large health care organization, modest gains in performance were achieved with the introduction of FFDM as a replacement for SFM. © 2017 Wiley Periodicals, Inc.

  13. Analyzing Distributed Functions in an Integrated Hazard Analysis

    NASA Technical Reports Server (NTRS)

    Morris, A. Terry; Massie, Michael J.

    2010-01-01

    Large scale integration of today's aerospace systems is achievable through the use of distributed systems. Validating the safety of distributed systems is significantly more difficult as compared to centralized systems because of the complexity of the interactions between simultaneously active components. Integrated hazard analysis (IHA), a process used to identify unacceptable risks and to provide a means of controlling them, can be applied to either centralized or distributed systems. IHA, though, must be tailored to fit the particular system being analyzed. Distributed systems, for instance, must be analyzed for hazards in terms of the functions that rely on them. This paper will describe systems-oriented IHA techniques (as opposed to traditional failure-event or reliability techniques) that should be employed for distributed systems in aerospace environments. Special considerations will be addressed when dealing with specific distributed systems such as active thermal control, electrical power, command and data handling, and software systems (including the interaction with fault management systems). Because of the significance of second-order effects in large scale distributed systems, the paper will also describe how to analyze secondary functions to secondary functions through the use of channelization.

  14. The Universe at Moderate Redshift

    NASA Technical Reports Server (NTRS)

    Cen, Renyue; Ostriker, Jeremiah P.

    1997-01-01

    The report covers the work done in the past year and a wide range of fields including properties of clusters of galaxies; topological properties of galaxy distributions in terms of galaxy types; patterns of gravitational nonlinear clustering process; development of a ray tracing algorithm to study the gravitational lensing phenomenon by galaxies, clusters and large-scale structure, one of whose applications being the effects of weak gravitational lensing by large-scale structure on the determination of q(0); the origin of magnetic fields on the galactic and cluster scales; the topological properties of Ly(alpha) clouds the Ly(alpha) optical depth distribution; clustering properties of Ly(alpha) clouds; and a determination (lower bound) of Omega(b) based on the observed Ly(alpha) forest flux distribution. In the coming year, we plan to continue the investigation of Ly(alpha) clouds using larger dynamic range (about a factor of two) and better simulations (with more input physics included) than what we have now. We will study the properties of galaxies on 1 - 100h(sup -1) Mpc scales using our state-of-the-art large scale galaxy formation simulations of various cosmological models, which will have a resolution about a factor of 5 (in each dimension) better than our current, best simulations. We will plan to study the properties of X-ray clusters using unprecedented, very high dynamic range (20,000) simulations which will enable us to resolve the cores of clusters while keeping the simulation volume sufficiently large to ensure a statistically fair sample of the objects of interest. The details of the last year's works are now described.

  15. A watershed scale spatially-distributed model for streambank erosion rate driven by channel curvature

    NASA Astrophysics Data System (ADS)

    McMillan, Mitchell; Hu, Zhiyong

    2017-10-01

    Streambank erosion is a major source of fluvial sediment, but few large-scale, spatially distributed models exist to quantify streambank erosion rates. We introduce a spatially distributed model for streambank erosion applicable to sinuous, single-thread channels. We argue that such a model can adequately characterize streambank erosion rates, measured at the outsides of bends over a 2-year time period, throughout a large region. The model is based on the widely-used excess-velocity equation and comprised three components: a physics-based hydrodynamic model, a large-scale 1-dimensional model of average monthly discharge, and an empirical bank erodibility parameterization. The hydrodynamic submodel requires inputs of channel centerline, slope, width, depth, friction factor, and a scour factor A; the large-scale watershed submodel utilizes watershed-averaged monthly outputs of the Noah-2.8 land surface model; bank erodibility is based on tree cover and bank height as proxies for root density. The model was calibrated with erosion rates measured in sand-bed streams throughout the northern Gulf of Mexico coastal plain. The calibrated model outperforms a purely empirical model, as well as a model based only on excess velocity, illustrating the utility of combining a physics-based hydrodynamic model with an empirical bank erodibility relationship. The model could be improved by incorporating spatial variability in channel roughness and the hydrodynamic scour factor, which are here assumed constant. A reach-scale application of the model is illustrated on ∼1 km of a medium-sized, mixed forest-pasture stream, where the model identifies streambank erosion hotspots on forested and non-forested bends.

  16. Solutions of large-scale electromagnetics problems involving dielectric objects with the parallel multilevel fast multipole algorithm.

    PubMed

    Ergül, Özgür

    2011-11-01

    Fast and accurate solutions of large-scale electromagnetics problems involving homogeneous dielectric objects are considered. Problems are formulated with the electric and magnetic current combined-field integral equation and discretized with the Rao-Wilton-Glisson functions. Solutions are performed iteratively by using the multilevel fast multipole algorithm (MLFMA). For the solution of large-scale problems discretized with millions of unknowns, MLFMA is parallelized on distributed-memory architectures using a rigorous technique, namely, the hierarchical partitioning strategy. Efficiency and accuracy of the developed implementation are demonstrated on very large problems involving as many as 100 million unknowns.

  17. Modification in drag of turbulent boundary layers resulting from manipulation of large-scale structures

    NASA Technical Reports Server (NTRS)

    Corke, T. C.; Guezennec, Y.; Nagib, H. M.

    1981-01-01

    The effects of placing a parallel-plate turbulence manipulator in a boundary layer are documented through flow visualization and hot wire measurements. The boundary layer manipulator was designed to manage the large scale structures of turbulence leading to a reduction in surface drag. The differences in the turbulent structure of the boundary layer are summarized to demonstrate differences in various flow properties. The manipulator inhibited the intermittent large scale structure of the turbulent boundary layer for at least 70 boundary layer thicknesses downstream. With the removal of the large scale, the streamwise turbulence intensity levels near the wall were reduced. The downstream distribution of the skin friction was also altered by the introduction of the manipulator.

  18. Time for a re-evaluation of mammography in the young? Results of an audit of mammography in women younger than 40 in a resource restricted environment.

    PubMed

    Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin

    2011-08-01

    Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.

  19. Breast dosimetry in clinical mammography

    NASA Astrophysics Data System (ADS)

    Benevides, Luis Alberto Do Rego

    The objective of this study was show that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. In the study, AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The protocol proposes the use of a fiber-optic coupled (FOCD) or Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeter to measure the entrance skin exposure at the time of the mammogram without interfering with diagnostic information of the mammogram. The study showed that FOCD had sensitivity with less than 7% energy dependence, linear in all tube current-time product stations, and was reproducible within 2%. FOCD was superior to MOSFET dosimeter in sensitivity, reusability, and reproducibility. The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. In addition, the study population anthropometric measurements enabled the development of analytical equations to calculate the whole breast area, estimate for the skin layer thickness and optimal location for automatic exposure control ionization chamber. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

  20. Time to definitive diagnosis of breast cancer in Latina and non-Hispanic white women: the six cities study.

    PubMed

    Ramirez, Amelie G; Pérez-Stable, Eliseo J; Talavera, Gregory A; Penedo, Frank J; Carrillo, J Emilio; Fernandez, Maria E; Muñoz, Edgar; Long Parma, Dorothy; Holden, Alan Ec; San Miguel de Majors, Sandra; Nápoles, Anna; Castañeda, Sheila F; Gallion, Kipling J

    2013-12-01

    Time delay after an abnormal screening mammogram may have a critical impact on tumor size, stage at diagnosis, treatment, prognosis, and survival of subsequent breast cancer. This study was undertaken to evaluate disparities between Latina and non-Hispanic white (NHW) women in time to definitive diagnosis of breast cancer after an abnormal screening mammogram, as well as factors contributing to such disparities. As part of the activities of the National Cancer Institute (NCI)-funded Redes En Acción research network, clinical records of 186 Latinas and 74 NHWs who received abnormal screening mammogram results were reviewed to determine the time to obtain a definitive diagnosis. Data was obtained from participating clinics in six U.S. cities and included demographics, clinical history, and mammogram characteristics. Kaplan-Meier estimates and Cox proportional hazards models were used to test differences in median time to definitive diagnosis by ethnicity after adjusting for clinic site, demographics, and clinical characteristics. Time-to-event analysis showed that Latinas took 2.2 times longer to reach 50% definitively diagnosed with breast cancer relative to NHWs, and three times longer to reach 80% diagnosed (p=0.001). Latinas' median time to definitive diagnosis was 60 days compared to 27 for NHWs, a 59% gap in diagnosis rates (adjusted Hazard Ratio [aHR] = 1.59, 95% CI = 1.09, 2.31; p=0.015). BI-RADS-4/5 women's diagnosis rate was more than twice that of BI-RADS-3 (aHR = 2.11, 95% CI = 1.18, 3.78; p=0.011). Disparities in time between receipt of abnormal screening result and definitive diagnosis adversely affect Latinas compared to NHWs, and remain significant after adjusting for demographic and clinical variables. With cancer now the leading cause of mortality among Latinos, a greater need exists for ethnically and culturally appropriate interventions like patient navigation to facilitate Latinas' successful entry into, and progression through, the cancer care system.

  1. Staging of breast cancer and the advanced applications of digital mammogram: what the physician needs to know?

    PubMed

    Helal, Maha H; Mansour, Sahar M; Zaglol, Mai; Salaleldin, Lamia A; Nada, Omniya M; Haggag, Marwa A

    2017-03-01

    To study the role of advanced applications of digital mammogram, whether contrast-enhanced spectral mammography (CESM) or digital breast tomosynthesis (DBT), in the "T" staging of histologically proven breast cancer before planning for treatment management. In this prospective analysis, we evaluated 98 proved malignant breast masses regarding their size, multiplicity and the presence of associated clusters of microcalcifications. Evaluation methods included digital mammography (DM), 3D tomosynthesis and CESM. Traditional DM was first performed then in a period of 10-14-day interval; breast tomosynthesis and contrast-based mammography were performed for the involved breast only. Views at tomosynthesis were acquired in a "step-and-shoot" tube motion mode to produce multiple (11-15), low-dose images and in contrast-enhanced study, low-energy (22-33 kVp) and high-energy (44-49 kVp) exposures were taken after the i.v. injection of the contrast agent. Operative data were the gold standard reference. Breast tomosynthesis showed the highest accuracy in size assessment (n = 69, 70.4%) than contrast-enhanced (n = 49, 50%) and regular mammography (n = 59, 60.2%). Contrast-enhanced mammography presented the least performance in assessing calcifications, yet it was most sensitive in the detection of multiplicity (92.3%), followed by tomosynthesis (77%) and regular mammography (53.8%). The combined analysis of the three modalities provided an accuracy of 74% in the "T" staging of breast cancer. The combined application of tomosynthesis and contrast-enhanced digital mammogram enhanced the performance of the traditional DM and presented an informative method in the staging of breast cancer. Advances in knowledge: Staging and management planning of breast cancer can divert according to tumour size, multiplicity and the presence of microcalcifications. DBT shows sharp outlines of the tumour with no overlap tissue and spots microcalcifications. Contrast-enhanced spectral mammogram shows the extent of abnormal contrast uptake and detects multiplicity. Integrated analysis provides optimal findings for proper "T" staging of breast cancer.

  2. Breast Cancer Screening in Patients With Newly Diagnosed Lung and Colorectal Cancer: A Population-Based Study of Utilization

    PubMed Central

    Sadigh, Gelareh; Carlos, Ruth C.; Ward, Kevin C.; Switchenko, Jeffrey M.; Jiang, Renjian; Applegate, Kimberly E.; Duszak, Richard

    2017-01-01

    Purpose To assess breast cancer screening utilization in Medicare beneficiaries with colorectal and lung cancer versus cancer-free controls. Methods Female fee-for-service Medicare beneficiaries who were ≥67 years old and diagnosed with lung or colorectal cancer between 2000 and 2011 and who reported to a Surveillance, Epidemiology, and End Results (SEER) registry (case group) were followed for 2 years after their diagnoses, unless death, a diagnosis of breast cancer, or the end of 2013 came first. A similar number of cancer-free controls were individually matched to cases by age, race, registry region, and follow-up time. Screening utilization was defined as the percentage of women with ≥1 screening mammogram during follow-up. Results Overall, 104,164 cases (48% colorectal, 52% lung; 30% advanced cancer) and 104,164 controls were included. Among women with lung or colorectal cancer, 22% underwent ≥1 screening mammogram versus 26% of controls (odds ratio [OR] 0.80; 95% confidence interval [CI] 0.78–0.82). Stratified by cancer type, 28% of colorectal cancer cases versus 29% of controls (OR 0.98; 95% CI 0.95–1.01) and 17% of lung cancer cases versus 23% of controls (OR 0.63; 95% CI 0.60–0.65) received ≥1 mammogram. When stratified by stage, 8% with advanced cancer versus 18% of controls (OR 0.33; 95% CI 0.31–0.35) and 30% with early-stage cancer versus 30% of controls (OR 1; 95% CI 0.97–1.02) underwent ≥1 mammogram. Conclusion Screening mammography utilization rates are similar between Medicare beneficiaries with early-stage cancer versus controls. Although the majority of patients with advanced-stage cancer appropriately do not pursue screening mammography, a small number (8%) continue with screening. PMID:28325489

  3. Breast Cancer Screening in Patients With Newly Diagnosed Lung and Colorectal Cancer: A Population-Based Study of Utilization.

    PubMed

    Sadigh, Gelareh; Carlos, Ruth C; Ward, Kevin C; Switchenko, Jeffrey M; Jiang, Renjian; Applegate, Kimberly E; Duszak, Richard

    2017-07-01

    To assess breast cancer screening utilization in Medicare beneficiaries with colorectal and lung cancer versus cancer-free controls. Female fee-for-service Medicare beneficiaries who were ≥67 years old and diagnosed with lung or colorectal cancer between 2000 and 2011 and who reported to a Surveillance, Epidemiology, and End Results (SEER) registry (case group) were followed for 2 years after their diagnoses, unless death, a diagnosis of breast cancer, or the end of 2013 came first. A similar number of cancer-free controls were individually matched to cases by age, race, registry region, and follow-up time. Screening utilization was defined as the percentage of women with ≥1 screening mammogram during follow-up. Overall, 104,164 cases (48% colorectal, 52% lung; 30% advanced cancer) and 104,164 controls were included. Among women with lung or colorectal cancer, 22% underwent ≥1 screening mammogram versus 26% of controls (odds ratio [OR] 0.80; 95% confidence interval [CI] 0.78-0.82). Stratified by cancer type, 28% of colorectal cancer cases versus 29% of controls (OR 0.98; 95% CI 0.95-1.01) and 17% of lung cancer cases versus 23% of controls (OR 0.63; 95% CI 0.60-0.65) received ≥1 mammogram. When stratified by stage, 8% with advanced cancer versus 18% of controls (OR 0.33; 95% CI 0.31-0.35) and 30% with early-stage cancer versus 30% of controls (OR 1; 95% CI 0.97-1.02) underwent ≥1 mammogram. Screening mammography utilization rates are similar between Medicare beneficiaries with early-stage cancer versus controls. Although the majority of patients with advanced-stage cancer appropriately do not pursue screening mammography, a small number (8%) continue with screening. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. A population-based tissue probability map-driven level set method for fully automated mammographic density estimations.

    PubMed

    Kim, Youngwoo; Hong, Byung Woo; Kim, Seung Ja; Kim, Jong Hyo

    2014-07-01

    A major challenge when distinguishing glandular tissues on mammograms, especially for area-based estimations, lies in determining a boundary on a hazy transition zone from adipose to glandular tissues. This stems from the nature of mammography, which is a projection of superimposed tissues consisting of different structures. In this paper, the authors present a novel segmentation scheme which incorporates the learned prior knowledge of experts into a level set framework for fully automated mammographic density estimations. The authors modeled the learned knowledge as a population-based tissue probability map (PTPM) that was designed to capture the classification of experts' visual systems. The PTPM was constructed using an image database of a selected population consisting of 297 cases. Three mammogram experts extracted regions for dense and fatty tissues on digital mammograms, which was an independent subset used to create a tissue probability map for each ROI based on its local statistics. This tissue class probability was taken as a prior in the Bayesian formulation and was incorporated into a level set framework as an additional term to control the evolution and followed the energy surface designed to reflect experts' knowledge as well as the regional statistics inside and outside of the evolving contour. A subset of 100 digital mammograms, which was not used in constructing the PTPM, was used to validate the performance. The energy was minimized when the initial contour reached the boundary of the dense and fatty tissues, as defined by experts. The correlation coefficient between mammographic density measurements made by experts and measurements by the proposed method was 0.93, while that with the conventional level set was 0.47. The proposed method showed a marked improvement over the conventional level set method in terms of accuracy and reliability. This result suggests that the proposed method successfully incorporated the learned knowledge of the experts' visual systems and has potential to be used as an automated and quantitative tool for estimations of mammographic breast density levels.

  5. A practical large scale/high speed data distribution system using 8 mm libraries

    NASA Technical Reports Server (NTRS)

    Howard, Kevin

    1993-01-01

    Eight mm tape libraries are known primarily for their small size, large storage capacity, and low cost. However, many applications require an additional attribute which, heretofore, has been lacking -- high transfer rate. Transfer rate is particularly important in a large scale data distribution environment -- an environment in which 8 mm tape should play a very important role. Data distribution is a natural application for 8 mm for several reasons: most large laboratories have access to 8 mm tape drives, 8 mm tapes are upwardly compatible, 8 mm media are very inexpensive, 8 mm media are light weight (important for shipping purposes), and 8 mm media densely pack data (5 gigabytes now and 15 gigabytes on the horizon). If the transfer rate issue were resolved, 8 mm could offer a good solution to the data distribution problem. To that end Exabyte has analyzed four ways to increase its transfer rate: native drive transfer rate increases, data compression at the drive level, tape striping, and homogeneous drive utilization. Exabyte is actively pursuing native drive transfer rate increases and drive level data compression. However, for non-transmitted bulk data applications (which include data distribution) the other two methods (tape striping and homogeneous drive utilization) hold promise.

  6. A distributed parallel storage architecture and its potential application within EOSDIS

    NASA Technical Reports Server (NTRS)

    Johnston, William E.; Tierney, Brian; Feuquay, Jay; Butzer, Tony

    1994-01-01

    We describe the architecture, implementation, use of a scalable, high performance, distributed-parallel data storage system developed in the ARPA funded MAGIC gigabit testbed. A collection of wide area distributed disk servers operate in parallel to provide logical block level access to large data sets. Operated primarily as a network-based cache, the architecture supports cooperation among independently owned resources to provide fast, large-scale, on-demand storage to support data handling, simulation, and computation.

  7. A quark model analysis of orbital angular momentum

    NASA Astrophysics Data System (ADS)

    Scopetta, Sergio; Vento, Vicente

    1999-08-01

    Orbital Angular Momentum (OAM) twist-two parton distributions are studied. At the low energy, hadronic, scale we calculate them for the relativistic MIT bag model and for non-relativistic potential quark models. We reach the scale of the data by leading order evolution using the OPE and perturbative QCD. We confirm that the contribution of quarks and gluons OAM to the nucleon spin grows with Q2, and it can be relevant at the experimental scale, even if it is negligible at the hadronic scale, irrespective of the model used. The sign and shape of the quark OAM distribution at high Q2 may depend strongly on the relative size of the OAM and spin distributions at the hadronic scale. Sizeable quark OAM distributions at the hadronic scale, as proposed by several authors, can produce the dominant contribution to the nucleon spin at high Q2. As expected by general arguments, we obtain, that the large gluon OAM contribution is almost cancelled by the gluon spin contribution.

  8. ADMS Evaluation Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2018-01-23

    Deploying an ADMS or looking to optimize its value? NREL offers a low-cost, low-risk evaluation platform for assessing ADMS performance. The National Renewable Energy Laboratory (NREL) has developed a vendor-neutral advanced distribution management system (ADMS) evaluation platform and is expanding its capabilities. The platform uses actual grid-scale hardware, large-scale distribution system models, and advanced visualization to simulate realworld conditions for the most accurate ADMS evaluation and experimentation.

  9. Non-Gaussian Nature of Fracture and the Survival of Fat-Tail Exponents

    NASA Astrophysics Data System (ADS)

    Tallakstad, Ken Tore; Toussaint, Renaud; Santucci, Stephane; Måløy, Knut Jørgen

    2013-04-01

    We study the fluctuations of the global velocity Vl(t), computed at various length scales l, during the intermittent mode-I propagation of a crack front. The statistics converge to a non-Gaussian distribution, with an asymmetric shape and a fat tail. This breakdown of the central limit theorem (CLT) is due to the diverging variance of the underlying local crack front velocity distribution, displaying a power law tail. Indeed, by the application of a generalized CLT, the full shape of our experimental velocity distribution at large scale is shown to follow the stable Levy distribution, which preserves the power law tail exponent under upscaling. This study aims to demonstrate in general for crackling noise systems how one can infer the complete scale dependence of the activity—and extreme event distributions—by measuring only at a global scale.

  10. Dynamical links between small- and large-scale mantle heterogeneity: Seismological evidence

    NASA Astrophysics Data System (ADS)

    Frost, Daniel A.; Garnero, Edward J.; Rost, Sebastian

    2018-01-01

    We identify PKP • PKP scattered waves (also known as P‧ •P‧) from earthquakes recorded at small-aperture seismic arrays at distances less than 65°. P‧ •P‧ energy travels as a PKP wave through the core, up into the mantle, then scatters back down through the core to the receiver as a second PKP. P‧ •P‧ waves are unique in that they allow scattering heterogeneities throughout the mantle to be imaged. We use array-processing methods to amplify low amplitude, coherent scattered energy signals and resolve their incoming direction. We deterministically map scattering heterogeneity locations from the core-mantle boundary to the surface. We use an extensive dataset with sensitivity to a large volume of the mantle and a location method allowing us to resolve and map more heterogeneities than have previously been possible, representing a significant increase in our understanding of small-scale structure within the mantle. Our results demonstrate that the distribution of scattering heterogeneities varies both radially and laterally. Scattering is most abundant in the uppermost and lowermost mantle, and a minimum in the mid-mantle, resembling the radial distribution of tomographically derived whole-mantle velocity heterogeneity. We investigate the spatial correlation of scattering heterogeneities with large-scale tomographic velocities, lateral velocity gradients, the locations of deep-seated hotspots and subducted slabs. In the lowermost 1500 km of the mantle, small-scale heterogeneities correlate with regions of low seismic velocity, high lateral seismic gradient, and proximity to hotspots. In the upper 1000 km of the mantle there is no significant correlation between scattering heterogeneity location and subducted slabs. Between 600 and 900 km depth, scattering heterogeneities are more common in the regions most remote from slabs, and close to hotspots. Scattering heterogeneities show an affinity for regions close to slabs within the upper 200 km of the mantle. The similarity between the distribution of large-scale and small-scale mantle structures suggests a dynamic connection across scales, whereby mantle heterogeneities of all sizes may be directed in similar ways by large-scale convective currents.

  11. Mammograms

    MedlinePlus

    ... gov/widgets/fahc.html" width="243" height="179" title="Find a Health Center Widget" ... M.D., Community Oncology and Prevention Trials Research Group, Division of Cancer Prevention, National Cancer Institute, ...

  12. The Large-Scale Structure of Semantic Networks: Statistical Analyses and a Model of Semantic Growth

    ERIC Educational Resources Information Center

    Steyvers, Mark; Tenenbaum, Joshua B.

    2005-01-01

    We present statistical analyses of the large-scale structure of 3 types of semantic networks: word associations, WordNet, and Roget's Thesaurus. We show that they have a small-world structure, characterized by sparse connectivity, short average path lengths between words, and strong local clustering. In addition, the distributions of the number of…

  13. Voltage Impacts of Utility-Scale Distributed Wind

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, A.

    2014-09-01

    Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbinemore » interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.« less

  14. Particle Acceleration in Mildly Relativistic Shearing Flows: The Interplay of Systematic and Stochastic Effects, and the Origin of the Extended High-energy Emission in AGN Jets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ruo-Yu; Rieger, F. M.; Aharonian, F. A., E-mail: ruoyu@mpi-hd.mpg.de, E-mail: frank.rieger@mpi-hd.mpg.de, E-mail: aharon@mpi-hd.mpg.de

    The origin of the extended X-ray emission in the large-scale jets of active galactic nuclei (AGNs) poses challenges to conventional models of acceleration and emission. Although electron synchrotron radiation is considered the most feasible radiation mechanism, the formation of the continuous large-scale X-ray structure remains an open issue. As astrophysical jets are expected to exhibit some turbulence and shearing motion, we here investigate the potential of shearing flows to facilitate an extended acceleration of particles and evaluate its impact on the resultant particle distribution. Our treatment incorporates systematic shear and stochastic second-order Fermi effects. We show that for typical parametersmore » applicable to large-scale AGN jets, stochastic second-order Fermi acceleration, which always accompanies shear particle acceleration, can play an important role in facilitating the whole process of particle energization. We study the time-dependent evolution of the resultant particle distribution in the presence of second-order Fermi acceleration, shear acceleration, and synchrotron losses using a simple Fokker–Planck approach and provide illustrations for the possible emergence of a complex (multicomponent) particle energy distribution with different spectral branches. We present examples for typical parameters applicable to large-scale AGN jets, indicating the relevance of the underlying processes for understanding the extended X-ray emission and the origin of ultrahigh-energy cosmic rays.« less

  15. 4D co-registration of X-ray and MR-mammograms: initial clinical results and potential incremental diagnostic value.

    PubMed

    Dietzel, Matthias; Hopp, Torsten; Ruiter, Nicole V; Kaiser, Clemens G; Kaiser, Werner A; Baltzer, Pascal A

    2015-01-01

    4D co-registration of X-ray- and MR-mammograms (XM and MM) is a new method of image fusion. The present study aims to evaluate its clinical feasibility, radiological accuracy, and potential clinical value. XM and MM of 25 patients were co-registered. Results were evaluated by a blinded reader. Precision of the 4D co-registration was "very good" (mean-score [ms]=7), and lesions were "easier to delineate" (ms=5). In 88.8%, "relevant additional diagnostic information" was present, accounting for a more "confident diagnosis" in 76% (ms=5). 4D co-registration is feasible, accurate, and of potential clinical value. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Distributions and Changes of Carbonate Parameters Along the U.S. East Coast

    NASA Astrophysics Data System (ADS)

    Xu, Y. Y.; Cai, W. J.; Wanninkhof, R. H.; Salisbury, J., II

    2017-12-01

    On top of anthropogenic climate change, upwelling, eutrophication, river discharge, and interactions with the open ocean have affected carbonate chemistry in coastal waters. In this study, we present the large-scale variations of carbonate parameters along the U.S. east coast using in situ observations obtained during an East Coast Ocean Acidification (ECOA) cruise in summer 2015. Compare with previous large-scale cruises along the east coast, the ECOA cruise increases spatial coverage in the Gulf of Marine region and has more offshore stations for a better understanding of carbon dynamics in coastal waters and their interactions with open ocean waters. Our results show that the spatial distribution of water mass properties set up the large-scale advection of salt and heat and the distribution of total alkalinity (TA). However, dissolved inorganic carbon (DIC) shows a distinct pattern. Coastal water pH displays high variability in the Gulf of Maine and the Mid-Atlantic Bight (MAB). But it is relatively homogeneous in the South Atlantic Bight (SAB). In contrast, the distribution of aragonite saturation state (Ω) has an increase pattern from north to south similar to those of TA, SST, and SSS. A mechanistic discussion will be presented to understand the controls on Ω in eastern coastal waters. A comparison with previous cruises also suggests very different changes of pH and Ω in the MAB and SAB. Preliminary analysis suggests an overall increase in surface pH and Ω in the MAB. In contrast, pH and Ω in the SAB surface waters decrease over the past two decades. This work serves as a platform for the monitoring of large-scale carbon cycling in the U.S. east coast. It is also important to identify the physical and biogeochemical processes that affect these distributions and changes over time for a better understanding of carbon cycling and ocean acidification in coastal waters.

  17. Modeling spatially-varying landscape change points in species occurrence thresholds

    USGS Publications Warehouse

    Wagner, Tyler; Midway, Stephen R.

    2014-01-01

    Predicting species distributions at scales of regions to continents is often necessary, as large-scale phenomena influence the distributions of spatially structured populations. Land use and land cover are important large-scale drivers of species distributions, and landscapes are known to create species occurrence thresholds, where small changes in a landscape characteristic results in abrupt changes in occurrence. The value of the landscape characteristic at which this change occurs is referred to as a change point. We present a hierarchical Bayesian threshold model (HBTM) that allows for estimating spatially varying parameters, including change points. Our model also allows for modeling estimated parameters in an effort to understand large-scale drivers of variability in land use and land cover on species occurrence thresholds. We use range-wide detection/nondetection data for the eastern brook trout (Salvelinus fontinalis), a stream-dwelling salmonid, to illustrate our HBTM for estimating and modeling spatially varying threshold parameters in species occurrence. We parameterized the model for investigating thresholds in landscape predictor variables that are measured as proportions, and which are therefore restricted to values between 0 and 1. Our HBTM estimated spatially varying thresholds in brook trout occurrence for both the proportion agricultural and urban land uses. There was relatively little spatial variation in change point estimates, although there was spatial variability in the overall shape of the threshold response and associated uncertainty. In addition, regional mean stream water temperature was correlated to the change point parameters for the proportion of urban land use, with the change point value increasing with increasing mean stream water temperature. We present a framework for quantify macrosystem variability in spatially varying threshold model parameters in relation to important large-scale drivers such as land use and land cover. Although the model presented is a logistic HBTM, it can easily be extended to accommodate other statistical distributions for modeling species richness or abundance.

  18. Novel Directional Protection Scheme for the FREEDM Smart Grid System

    NASA Astrophysics Data System (ADS)

    Sharma, Nitish

    This research primarily deals with the design and validation of the protection system for a large scale meshed distribution system. The large scale system simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms, to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. The addition of distributed generation and power electronic based solid state transformer adds to the complexity of the protection. The FREEDM loop system has a fault current limiter and in addition, the Solid State Transformer (SST) limits the fault current at 2.0 per unit. Former students at ASU have developed the protection scheme using fiber-optic cable. However, during the NSF-FREEDM site visit, the National Science Foundation (NSF) team regarded the system incompatible for the long distances. Hence, a new protection scheme with a wireless scheme is presented in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The trip signal generated by the pilot protection system is used to trigger the FID (fault isolation device) which is an electronic circuit breaker operation (switched off/opening the FIDs). The trip signal must be received and accepted by the SST, and it must block the SST operation immediately. A comprehensive protection system for the large scale meshed distribution system has been developed in PSCAD with the ability to quickly detect the faults. The validation of the protection system is performed by building a hardware model using commercial relays at the ASU power laboratory.

  19. Why small-scale cannabis growers stay small: five mechanisms that prevent small-scale growers from going large scale.

    PubMed

    Hammersvik, Eirik; Sandberg, Sveinung; Pedersen, Willy

    2012-11-01

    Over the past 15-20 years, domestic cultivation of cannabis has been established in a number of European countries. New techniques have made such cultivation easier; however, the bulk of growers remain small-scale. In this study, we explore the factors that prevent small-scale growers from increasing their production. The study is based on 1 year of ethnographic fieldwork and qualitative interviews conducted with 45 Norwegian cannabis growers, 10 of whom were growing on a large-scale and 35 on a small-scale. The study identifies five mechanisms that prevent small-scale indoor growers from going large-scale. First, large-scale operations involve a number of people, large sums of money, a high work-load and a high risk of detection, and thus demand a higher level of organizational skills than for small growing operations. Second, financial assets are needed to start a large 'grow-site'. Housing rent, electricity, equipment and nutrients are expensive. Third, to be able to sell large quantities of cannabis, growers need access to an illegal distribution network and knowledge of how to act according to black market norms and structures. Fourth, large-scale operations require advanced horticultural skills to maximize yield and quality, which demands greater skills and knowledge than does small-scale cultivation. Fifth, small-scale growers are often embedded in the 'cannabis culture', which emphasizes anti-commercialism, anti-violence and ecological and community values. Hence, starting up large-scale production will imply having to renegotiate or abandon these values. Going from small- to large-scale cannabis production is a demanding task-ideologically, technically, economically and personally. The many obstacles that small-scale growers face and the lack of interest and motivation for going large-scale suggest that the risk of a 'slippery slope' from small-scale to large-scale growing is limited. Possible political implications of the findings are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Optical Demonstration of a Medical Imaging System with an EMCCD-Sensor Array for Use in a High Resolution Dynamic X-ray Imager

    PubMed Central

    Qu, Bin; Huang, Ying; Wang, Weiyuan; Sharma, Prateek; Kuhls-Gilcrist, Andrew T.; Cartwright, Alexander N.; Titus, Albert H.; Bednarek, Daniel R.; Rudin, Stephen

    2011-01-01

    Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained. PMID:23505330

  1. Characterization of spray-induced turbulence using fluorescence PIV

    NASA Astrophysics Data System (ADS)

    van der Voort, Dennis D.; Dam, Nico J.; Clercx, Herman J. H.; Water, Willem van de

    2018-07-01

    The strong shear induced by the injection of liquid sprays at high velocities induces turbulence in the surrounding medium. This, in turn, influences the motion of droplets as well as the mixing of air and vapor. Using fluorescence-based tracer particle image velocimetry, the velocity field surrounding 125-135 m/s sprays exiting a 200-μm nozzle is analyzed. For the first time, the small- and large-scale turbulence characteristics of the gas phase surrounding a spray has been measured simultaneously, using a large eddy model to determine the sub-grid scales. This further allows the calculation of the Stokes numbers of droplets, which indicates the influence of turbulence on their motion. The measurements lead to an estimate of the dissipation rate ɛ ≈ 35 m2 s^{-3}, a microscale Reynolds number Re_{λ } ≈ 170, and a Kolmogorov length scale of η ≈ 10^{-4} m. Using these dissipation rates to convert a droplet size distribution to a distribution of Stokes numbers, we show that only the large scale motion of turbulence disperses the droplet in the current case, but the small scales will grow in importance with increasing levels of atomization and ambient pressures.

  2. Large-Scale Distributed Computational Fluid Dynamics on the Information Power Grid Using Globus

    NASA Technical Reports Server (NTRS)

    Barnard, Stephen; Biswas, Rupak; Saini, Subhash; VanderWijngaart, Robertus; Yarrow, Maurice; Zechtzer, Lou; Foster, Ian; Larsson, Olle

    1999-01-01

    This paper describes an experiment in which a large-scale scientific application development for tightly-coupled parallel machines is adapted to the distributed execution environment of the Information Power Grid (IPG). A brief overview of the IPG and a description of the computational fluid dynamics (CFD) algorithm are given. The Globus metacomputing toolkit is used as the enabling device for the geographically-distributed computation. Modifications related to latency hiding and Load balancing were required for an efficient implementation of the CFD application in the IPG environment. Performance results on a pair of SGI Origin 2000 machines indicate that real scientific applications can be effectively implemented on the IPG; however, a significant amount of continued effort is required to make such an environment useful and accessible to scientists and engineers.

  3. GLAD: a system for developing and deploying large-scale bioinformatics grid.

    PubMed

    Teo, Yong-Meng; Wang, Xianbing; Ng, Yew-Kwong

    2005-03-01

    Grid computing is used to solve large-scale bioinformatics problems with gigabytes database by distributing the computation across multiple platforms. Until now in developing bioinformatics grid applications, it is extremely tedious to design and implement the component algorithms and parallelization techniques for different classes of problems, and to access remotely located sequence database files of varying formats across the grid. In this study, we propose a grid programming toolkit, GLAD (Grid Life sciences Applications Developer), which facilitates the development and deployment of bioinformatics applications on a grid. GLAD has been developed using ALiCE (Adaptive scaLable Internet-based Computing Engine), a Java-based grid middleware, which exploits the task-based parallelism. Two bioinformatics benchmark applications, such as distributed sequence comparison and distributed progressive multiple sequence alignment, have been developed using GLAD.

  4. Model for non-Gaussian intraday stock returns

    NASA Astrophysics Data System (ADS)

    Gerig, Austin; Vicente, Javier; Fuentes, Miguel A.

    2009-12-01

    Stock prices are known to exhibit non-Gaussian dynamics, and there is much interest in understanding the origin of this behavior. Here, we present a model that explains the shape and scaling of the distribution of intraday stock price fluctuations (called intraday returns) and verify the model using a large database for several stocks traded on the London Stock Exchange. We provide evidence that the return distribution for these stocks is non-Gaussian and similar in shape and that the distribution appears stable over intraday time scales. We explain these results by assuming the volatility of returns is constant intraday but varies over longer periods such that its inverse square follows a gamma distribution. This produces returns that are Student distributed for intraday time scales. The predicted results show excellent agreement with the data for all stocks in our study and over all regions of the return distribution.

  5. Investigation of low-latitude hydrogen emission in terms of a two-component interstellar gas model

    NASA Technical Reports Server (NTRS)

    Baker, P. L.; Burton, W. B.

    1975-01-01

    High-resolution 21-cm hydrogen line observations at low galactic latitude are analyzed to determine the large-scale distribution of galactic hydrogen. Distribution parameters are found by model fitting, optical depth effects are computed using a two-component gas model suggested by the observations, and calculations are made for a one-component uniform spin-temperature gas model to show the systematic departures between this model and data obtained by incorrect treatment of the optical depth effects. Synthetic 21-cm line profiles are computed from the two-component model, and the large-scale trends of the observed emission profiles are reproduced together with the magnitude of the small-scale emission irregularities. Values are determined for the thickness of the galactic hydrogen disk between half density points, the total observed neutral hydrogen mass of the galaxy, and the central number density of the intercloud hydrogen atoms. It is shown that typical hydrogen clouds must be between 1 and 13 pc in diameter and that optical thinness exists on large-scale despite the presence of optically thin gas.

  6. Direct numerical simulation of turbulent channel flow with spanwise alternatively distributed strips control

    NASA Astrophysics Data System (ADS)

    Ni, Weidan; Lu, Lipeng; Fang, Jian; Moulinec, Charles; Yao, Yufeng

    2018-05-01

    The effect of spanwise alternatively distributed strips (SADS) control on turbulent flow in a plane channel has been studied by direct numerical simulations to investigate the characteristics of large-scale streamwise vortices (LSSVs) induced by small-scale active wall actuation, and their potential in suppressing flow separation. SADS control is realized by alternatively arranging out-of-phase control (OPC) and in-phase control (IPC) wall actuations on the lower channel wall surface, in the spanwise direction. It is found that the coherent structures are suppressed or enhanced alternatively by OPC or IPC, respectively, leading to the formation of a vertical shear layer, which is responsible for the LSSVs’ presence. Large-scale low-speed region can also be observed above the OPC strips, which resemble large-scale low-speed streaks. LSSVs are found to be in a statistically-converged steady state and their cores are located between two neighboring OPC and IPC strips. Their motions contribute significantly to the momentum transport in the wall-normal and spanwise directions, demonstrating their potential ability to suppress flow separation.

  7. Cosmological explosions from cold dark matter perturbations

    NASA Technical Reports Server (NTRS)

    Scherrer, Robert J.

    1992-01-01

    The cosmological-explosion model is examined for a universe dominated by cold dark matter in which explosion seeds are produced from the growth of initial density perturbations of a given form. Fragmentation of the exploding shells is dominated by the dark-matter potential wells rather than the self-gravity of the shells, and particular conditions are required for the explosions to bootstrap up to very large scales. The final distribution of dark matter is strongly correlated with the baryons on small scales, but uncorrelated on large scales.

  8. Breast cancer screening

    MedlinePlus

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  9. Remote sensing of permafrost and geological hazards in Alaska

    NASA Technical Reports Server (NTRS)

    Ferrians, O. J., Jr. (Principal Investigator)

    1973-01-01

    The author has identified the following significant results. The study of the ERTS-1 imagery of Alaska indicates the following: that areas of different topographic expression affecting the distribution and character of permafrost can be distinguished clearly; that on the Arctic North Slope, regional differences in the distribution and character of permafrost-related oriented thaw lakes can be observed; that the distribution of certain types of geologic materials having a significant effect on the character of permafrost can be delineated on a regional scale; and that the resolution of the imagery is adequate to identify large scale geologic hazards such as landslides, glacier-dammed lakes, aufeis fields, etc. The information concerning the distribution and character of permafrost and geologic hazards to the gained in accomplishing the objectives of this project will be an invaluable aid in solving engineering-geologic and environmental problems related to route and site selection for structures such as roads, railroads, pipelines, and large installations; to distribution of natural construction materials; and to construction and maintenance.

  10. Impact of spatio-temporal scale of adjustment on variational assimilation of hydrologic and hydrometeorological data in operational distributed hydrologic models

    NASA Astrophysics Data System (ADS)

    Lee, H.; Seo, D.; McKee, P.; Corby, R.

    2009-12-01

    One of the large challenges in data assimilation (DA) into distributed hydrologic models is to reduce the large degrees of freedom involved in the inverse problem to avoid overfitting. To assess the sensitivity of the performance of DA to the dimensionality of the inverse problem, we design and carry out real-world experiments in which the control vector in variational DA (VAR) is solved at different scales in space and time, e.g., lumped, semi-distributed, and fully-distributed in space, and hourly, 6 hourly, etc., in time. The size of the control vector is related to the degrees of freedom in the inverse problem. For the assessment, we use the prototype 4-dimenational variational data assimilator (4DVAR) that assimilates streamflow, precipitation and potential evaporation data into the NWS Hydrology Laboratory’s Research Distributed Hydrologic Model (HL-RDHM). In this talk, we present the initial results for a number of basins in Oklahoma and Texas.

  11. Reconstruction of halo power spectrum from redshift-space galaxy distribution: cylinder-grouping method and halo exclusion effect

    NASA Astrophysics Data System (ADS)

    Okumura, Teppei; Takada, Masahiro; More, Surhud; Masaki, Shogo

    2017-07-01

    The peculiar velocity field measured by redshift-space distortions (RSD) in galaxy surveys provides a unique probe of the growth of large-scale structure. However, systematic effects arise when including satellite galaxies in the clustering analysis. Since satellite galaxies tend to reside in massive haloes with a greater halo bias, the inclusion boosts the clustering power. In addition, virial motions of the satellite galaxies cause a significant suppression of the clustering power due to non-linear RSD effects. We develop a novel method to recover the redshift-space power spectrum of haloes from the observed galaxy distribution by minimizing the contamination of satellite galaxies. The cylinder-grouping method (CGM) we study effectively excludes satellite galaxies from a galaxy sample. However, we find that this technique produces apparent anisotropies in the reconstructed halo distribution over all the scales which mimic RSD. On small scales, the apparent anisotropic clustering is caused by exclusion of haloes within the anisotropic cylinder used by the CGM. On large scales, the misidentification of different haloes in the large-scale structures, aligned along the line of sight, into the same CGM group causes the apparent anisotropic clustering via their cross-correlation with the CGM haloes. We construct an empirical model for the CGM halo power spectrum, which includes correction terms derived using the CGM window function at small scales as well as the linear matter power spectrum multiplied by a simple anisotropic function at large scales. We apply this model to a mock galaxy catalogue at z = 0.5, designed to resemble Sloan Digital Sky Survey-III Baryon Oscillation Spectroscopic Survey (BOSS) CMASS galaxies, and find that our model can predict both the monopole and quadrupole power spectra of the host haloes up to k < 0.5 {{h Mpc^{-1}}} to within 5 per cent.

  12. Magnetic pattern at supergranulation scale: the void size distribution

    NASA Astrophysics Data System (ADS)

    Berrilli, F.; Scardigli, S.; Del Moro, D.

    2014-08-01

    The large-scale magnetic pattern observed in the photosphere of the quiet Sun is dominated by the magnetic network. This network, created by photospheric magnetic fields swept into convective downflows, delineates the boundaries of large-scale cells of overturning plasma and exhibits "voids" in magnetic organization. These voids include internetwork fields, which are mixed-polarity sparse magnetic fields that populate the inner part of network cells. To single out voids and to quantify their intrinsic pattern we applied a fast circle-packing-based algorithm to 511 SOHO/MDI high-resolution magnetograms acquired during the unusually long solar activity minimum between cycles 23 and 24. The computed void distribution function shows a quasi-exponential decay behavior in the range 10-60 Mm. The lack of distinct flow scales in this range corroborates the hypothesis of multi-scale motion flows at the solar surface. In addition to the quasi-exponential decay, we have found that the voids depart from a simple exponential decay at about 35 Mm.

  13. Basic Equations Interrelate Atomic and Nuclear Properties to Patterns at the Size Scales of the Cosmos, Extended Clusters of Galaxies, Galaxies, and Nebulae

    NASA Astrophysics Data System (ADS)

    Allen, Rob

    2016-09-01

    Structures within molecules and nuclei have relationships to astronomical patterns. The COBE cosmic scale plots, and large scale surveys of galaxy clusters have patterns also repeating and well known at atomic scales. The Induction, Strong Force, and Nuclear Binding Energy Periods within the Big Bang are revealed to have played roles in the formation of these large scale distributions. Equations related to the enormous patterns also model chemical bonds and likely nucleus and nucleon substructures. ratios of the forces that include gravity are accurately calculated from the distributions and shapes. In addition, particle masses and a great many physical constants can be derived with precision and accuracy from astrophysical shapes. A few very basic numbers can do modelling from nucleon internals to molecules to super novae, and up to the Visible Universe. Equations are also provided along with possible structural configurations for some Cold Dark Matter and Dark Energy.

  14. Properties and spatial distribution of galaxy superclusters

    NASA Astrophysics Data System (ADS)

    Liivamägi, Lauri Juhan

    2017-01-01

    Astronomy is a science that can offer plenty of unforgettable imagery, and the large-scale distribution of galaxies is no exception. Among the first features the viewer's eye is likely to be drawn to, are large concentrations of galaxies - galaxy superclusters, contrasting to the seemingly empty regions beside them. Superclusters can extend from tens to over hundred megaparsecs, they contain from hundreds to thousands of galaxies, and many galaxy groups and clusters. Unlike galaxy clusters, superclusters are clearly unrelaxed systems, not gravitationally bound as crossing times exceed the age of the universe, and show little to no radial symmetry. Superclusters, as part of the large-scale structure, are sensitive to the initial power spectrum and the following evolution. They are massive enough to leave an imprint on the cosmic microwave background radiation. Superclusters can also provide an unique environment for their constituent galaxies and galaxy clusters. In this study we used two different observational and one simulated galaxy samples to create several catalogues of structures that, we think, correspond to what are generally considered galaxy superclusters. Superclusters were delineated as continuous over-dense regions in galaxy luminosity density fields. When calculating density fields several corrections were applied to remove small-scale redshift distortions and distance-dependent selection effects. Resulting catalogues of objects display robust statistical properties, showing that flux-limited galaxy samples can be used to create nearly volume-limited catalogues of superstructures. Generally, large superclusters can be regarded as massive, often branching filamentary structures, that are mainly characterised by their length. Smaller superclusters, on the other hand, can display a variety of shapes. Spatial distribution of superclusters shows large-scale variations, with high-density concentrations often found in semi-regularly spaced groups. Future studies are needed to quantify the relations between superclusters and finer details of the galaxy distribution. Supercluster catalogues from this thesis have already been used in numerous other studies.

  15. Law Enforcement Efforts to Control Domestically Grown Marijuana.

    DTIC Science & Technology

    1984-05-25

    mari- juana grown indoors , the involvement of large criminal organizations, and the patterns of domestic marijuana distribution. In response to a GAO...information is particularly important if the amount of marijuana grown indoors and the number of large-scale cultiva- tion and distribution organizations... marijuana indoors is becoming increasingly popular. A 1982 narcotics assessment by the Western States Information Network (WSIN)2 of marijuana

  16. An NCME Instructional Module on Booklet Designs in Large-Scale Assessments of Student Achievement: Theory and Practice

    ERIC Educational Resources Information Center

    Frey, Andreas; Hartig, Johannes; Rupp, Andre A.

    2009-01-01

    In most large-scale assessments of student achievement, several broad content domains are tested. Because more items are needed to cover the content domains than can be presented in the limited testing time to each individual student, multiple test forms or booklets are utilized to distribute the items to the students. The construction of an…

  17. Development of Novel Therapeutics for Neglected Tropical Disease Leishmaniasis

    DTIC Science & Technology

    2015-10-01

    Approved for public release; distribution unlimited We undertook planning of kick off coordination meeting. A low dose infection model of CL was validated...A large scale synthesis of PEN optimized and in vitro studies were performed revealed that PEN alters parasite lipidome. Further studies were...Pentalinonsterol, Leishmania, cutaneous leishmaniasis, treatment Accomplishments • Undertook planning of kick off coordination meeting • Large scale synthesis of

  18. Coalescence of repelling colloidal droplets: a route to monodisperse populations.

    PubMed

    Roger, Kevin; Botet, Robert; Cabane, Bernard

    2013-05-14

    Populations of droplets or particles dispersed in a liquid may evolve through Brownian collisions, aggregation, and coalescence. We have found a set of conditions under which these populations evolve spontaneously toward a narrow size distribution. The experimental system consists of poly(methyl methacrylate) (PMMA) nanodroplets dispersed in a solvent (acetone) + nonsolvent (water) mixture. These droplets carry electrical charges, located on the ionic end groups of the macromolecules. We used time-resolved small angle X-ray scattering to determine their size distribution. We find that the droplets grow through coalescence events: the average radius (R) increases logarithmically with elapsed time while the relative width σR/(R) of the distribution decreases as the inverse square root of (R). We interpret this evolution as resulting from coalescence events that are hindered by ionic repulsions between droplets. We generalize this evolution through a simulation of the Smoluchowski kinetic equation, with a kernel that takes into account the interactions between droplets. In the case of vanishing or attractive interactions, all droplet encounters lead to coalescence. The corresponding kernel leads to the well-known "self-preserving" particle distribution of the coalescence process, where σR/(R) increases to a plateau value. However, for droplets that interact through long-range ionic repulsions, "large + small" droplet encounters are more successful at coalescence than "large + large" encounters. We show that the corresponding kernel leads to a particular scaling of the droplet-size distribution-known as the "second-scaling law" in the theory of critical phenomena, where σR/(R) decreases as 1/√(R) and becomes independent of the initial distribution. We argue that this scaling explains the narrow size distributions of colloidal dispersions that have been synthesized through aggregation processes.

  19. The Large Local Hole in the Galaxy Distribution: The 2MASS Galaxy Angular Power Spectrum

    NASA Astrophysics Data System (ADS)

    Frith, W. J.; Outram, P. J.; Shanks, T.

    2005-06-01

    We present new evidence for a large deficiency in the local galaxy distribution situated in the ˜4000 deg2 APM survey area. We use models guided by the 2dF Galaxy Redshift Survey (2dFGRS) n(z) as a probe of the underlying large-scale structure. We first check the usefulness of this technique by comparing the 2dFGRS n(z) model prediction with the K-band and B-band number counts extracted from the 2MASS and 2dFGRS parent catalogues over the 2dFGRS Northern and Southern declination strips, before turning to a comparison with the APM counts. We find that the APM counts in both the B and K-bands indicate a deficiency in the local galaxy distribution of ˜30% to z ≈ 0.1 over the entire APM survey area. We examine the implied significance of such a large local hole, considering several possible forms for the real-space correlation function. We find that such a deficiency in the APM survey area indicates an excess of power at large scales over what is expected from the correlation function observed in 2dFGRS correlation function or predicted from ΛCDM Hubble Volume mock catalogues. In order to check further the clustering at large scales in the 2MASS data, we have calculated the angular power spectrum for 2MASS galaxies. Although in the linear regime (l<30), ΛCDM models can give a good fit to the 2MASS angular power spectrum, over a wider range (l<100) the power spectrum from Hubble Volume mock catalogues suggests that scale-dependent bias may be needed for ΛCDM to fit. However, the modest increase in large-scale power observed in the 2MASS angular power spectrum is still not enough to explain the local hole. If the APM survey area really is 25% deficient in galaxies out to z≈0.1, explanations for the disagreement with observed galaxy clustering statistics include the possibilities that the galaxy clustering is non-Gaussian on large scales or that the 2MASS volume is still too small to represent a `fair sample' of the Universe. Extending the 2dFGRS redshift survey over the whole APM area would resolve many of the remaining questions about the existence and interpretation of this local hole.

  20. Validation of the Spanish Version of the Mammography-Specific Self-Efficacy Scale.

    PubMed

    Jerome-D'Emilia, Bonnie; Suplee, Patricia; Akincigil, Ayse

    2015-05-01

    To consider psychometric estimates of the validity and reliability of the Spanish translation of a mammography-specific self-efficacy scale. A cross-sectional study. Three primarily Hispanic churches and a Hispanic community center in a low-income urban area of New Jersey. 153 low-income Hispanic women aged 40-85 years. The translated scale was administered to participants during a six-month period. Internal consistency, reliability, and construct and predictive validity were assessed. Demographic variables included income and insurance status. Outcome variables included total mammography-specific self-efficacy and having had a mammogram within the past two years. Preliminary evidence of reliability and validity were found, and predictive validity was demonstrated. The health needs of specific populations can be addressed only when research instruments have been appropriately validated and all relevant factors are considered. Diverse groups of low-income women face similar challenges and barriers in their efforts to get screened. Nurses are in an ideal position to help women with preventive care decision making (e.g., screening for breast cancer). Understanding how a woman's level of self-efficacy affects her decision making should be considered when counseling a client.

Top