Sample records for laser evaluation des

  1. Terre des Lasers: the new Aquitaine outreach and communication center in photonics

    NASA Astrophysics Data System (ADS)

    Prulhiere, Jean Paul; Sarger, Laurent

    2009-06-01

    The competitive cluster "Route des Lasers" has been labeled by the French Government in July 2005. In this context, it has launched in September 2005, in cooperation with Commissariat à l'Energie Atomique (CEA) and Regional Council a project involving scientific exhibitions, called "Terre des Lasers ®", in order to create an exhibition and an area of communication and science discovery or a very large target (public, school, industry) in the fields of optics, lasers, optronics and imaging. This initiative is part of the strategy of the "Route des Lasers" center which aims to promote technologies developed in the areas of photonics, targeting in particular children and teenagers and their awareness for this particular industrial and scientific topic.

  2. La Station Laser ultra mobile: de l'Obtention d'une Exactitude centimétrique des Mesures à des Applications en Océanographie et Géodésie Spatiales

    NASA Astrophysics Data System (ADS)

    Nicolas, Joëlle

    2000-12-01

    La Station Laser Ultra Mobile est la plus petite station de télémétrie laser au monde, ne pesant que 300 kg, dédiée à la poursuite de satellites équipés de rétroréflecteurs laser. Elle utilise un petit télescope de 13 cm de diamètre placé sur une monture issue d'un théodolite de précision et motorisé, un laser très compact et une photodiode à avalanche permettant la détection au niveau du simple photo-électron. Les premières expériences (Corse, fin 1996) ont révélé de nombreuses instabilités dans la qualité des mesures. Ce travail concerne l'étude et la mise en place de nombreuses modifications techniques afin d'atteindre une exactitude centimétrique des mesures et de pouvoir participer à la campagne de validation des orbites et d'étalonnage de l'altimètre du satellite océanographique JASON-1 (2001). La précision instrumentale souhaitée a été vérifiée avec succès en laboratoire. Outre cet aspect instrumental et métrologique, une analyse a été développée afin de pouvoir estimer l'exactitude et la stabilité des observations de la station mobile après intégration des modifications. A partir d'une expérience de co-localisation entre les deux stations laser fixe du plateau de Calern, l'analyse est basée sur l'ajustement, par station, de coordonnées et d'un biais instrumental moyen à partir d'une orbite de référence des satellites LAGEOS. Des variations saisonnières ont été mises en évidence dans les séries temporelles des différentes composantes. La comparaison locale des déformations de la croûte terrestre se traduisant par des variations d'altitude issues des données laser a montré une cohérence remarquable avec les mesures du gravimètre absolu transportable FG5. Des signaux de même amplitude ont aussi été observés par GPS. Ces variations sont également mises en évidence à l'échelle mondiale et leur interprétation géophysique est faite (combinaison des effets de marées terrestres et polaire

  3. Lasers solides pompés par diode émettant des impulsions picosecondes à haute cadence dans l'ultraviolet

    NASA Astrophysics Data System (ADS)

    Balembois, F.; Forget, S.; Papadopoulos, D.; Druon, F.; Georges, P.; Devilder, P.-J.; Lefort, L.

    2005-06-01

    De nombreuses applications requièrent des sources lasers impulsionnelles ultraviolettes, présentant des durées d'impulsion et des cadences spécifiques. Grâce à l'utilisation de structures d'oscillateurs et d'amplificateurs originales il est possible de réaliser de telles sources à partir de lasers solides pompés par diodes et de profiter ainsi de la compacité, de l'efficacité et de la robustesse de ces sources. Nous présentons ici la réalisation d'un laser à verrouillage de modes et d'un microlaser déclenché permettant d'obtenir des impulsions ultraviolettes picosecondes à une cadence de quelques MHz en vue d'application à la microscopie de fluorescence résolue en temps, ainsi que la mise en œuvre pour le traitement des matériaux d'un système oscillateur-amplificateur produisant plus de 600 mW de rayonnement UV à 266 ou 355 nm avec des impulsions sub-nanosecondes.

  4. Etudes optiques de nouveaux materiaux laser: Des orthosilicates dopes a l'ytterbium: Le yttrium (lutetium,scandium) pentoxide de silicium

    NASA Astrophysics Data System (ADS)

    Denoyer, Aurelie

    La decouverte et l'elaboration de nouveaux materiaux laser solides suscitent beaucoup d'interet parmi la communaute scientifique. En particulier les lasers dans la gamme de frequence du micron debouchent sur beaucoup d'applications, en telecommunication, en medecine, dans le domaine militaire, pour la, decoupe des metaux (lasers de puissance), en optique non lineaire (doublage de frequence, bistabilite optique). Le plus couramment utilise actuellement est le Nd:YAG dans cette famille de laser, mais des remplacants plus performants sont toujours recherches. Les lasers a base d'Yb3+ possedent beaucoup d'avantages compares aux lasers Nd3+ du fait de leur structure electronique simple et de leur deterioration moins rapide. Parmi les matrices cristallines pouvant accueillir l'ytterbium, les orthosilicates Yb:Y 2SiO5, Yb:Lu2SiO5 et Yb:Sc2SiO 5 se positionnent tres bien, du fait de leur bonne conductivite thermique et du fort eclatement de leur champ cristallin necessaire a l'elaboration de lasers quasi-3 niveaux. De plus l'etude fine et systematique des proprietes microscopiques de nouveaux materiaux s'avere toujours tres interessante du point de vue de la recherche fondamentale, c'est ainsi que de nouveaux modeles sont concus (par exemple pour le champ cristallin) ou que de nouvelles proprietes inhabituelles sont decouvertes, menant a de nouvelles applications. Ainsi d'autres materiaux dopes a l'ytterbium sont connus pour leurs proprietes de couplage electron-phonon, de couplage magnetique, d'emission cooperative ou encore de bistabilite optique, mais ces proprietes n'ont encore jamais ete mises en evidence dans Yb:Y 2SiO5, Yb:Lu2SiO5 et Yb:Sc2SiO 5. Ainsi, cette these a pour but l'etude des proprietes optiques et des interactions microscopiques dans Yb:Y2SiO 5, Yb:Lu2SiO5 et Yb:Sc2SiO5. Nous utilisons principalement les techniques d'absorption IR et de spectroscopie Raman pour determiner les excitations du champ cristallin et les modes de vibration dans le materiau

  5. Potentialités des lasers à fibre dans la génération de rayonnement cohérent UV

    NASA Astrophysics Data System (ADS)

    Martel, G.; Hideur, A.; Ortaç, B.; Lecourt, J.-B.; Chédot, C.; Brunel, M.; Chéron, B.; Limpert, J.; Tunnermann, T.; Grelu, Ph.; Gicquel-Guézo, M.; Labbé, C.; Loualiche, S.; Roussignol, Ph.; Sanchez, F.; Leblond, H.

    2006-12-01

    Le premier laser à fibre dopé aux ions de terres rares fonctionna au tout début des années 60. Il fournissait quelques milliwatts autour de 1 μm. Les décades suivantes virent très peu d'améliorations tant du côté des laboratoires que du point de vue industriel. La dernière décennie (1995/2005) vit se concrétiser la seconde révolution des lasers à fibres. Déjà kilowatt en continu, ils atteignent désormais les 1013 watts/cm2 avec des impulsions de la centaine de femtoseconde. Lors de cette présentation nous passerons en revue les potentialités des lasers à fibre. Nous décrirons les verrous technologiques qui ont été levés ces dix dernières années pour les régimes CW mais aussi femtosecondes. Nous montrerons également comment la prochaine génération de fibres optiques actuellement en développement permettra d'offrir des sources stables et de très haute puissance pour l'avenir proche.

  6. Un projet d'horloge atomique spatiale utlilsant le refroidissement des atomes par faisceaux laser: PHARAO

    NASA Astrophysics Data System (ADS)

    Laurent, Ph.; Lemonde, P.; Simon, E.; Santarelli, G.; Petit, P.; Dimarcq, N.; Clairon, A.; Salomon, C.; Audoin, C.; Changeart, F. Jamin; Gonzalez, F.

    2018-04-01

    This paper, "Un projet d'horloge atomique spatiale utlilsant le refroidissement des atomes par faisceaux laser: PHARAO," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  7. L'evaluation des politiques institutionnelles d'evaluation des apprentissages. Rapport synthese (The Evaluation of Institutional Policies of Evaluation of Learning. Synthesis Report). 2410-0520.

    ERIC Educational Resources Information Center

    Lindfelt, Bengt, Ed.

    In accordance with provincial educational regulations, Quebec's community colleges have adopted "politiques institutionnelles d'evaluation des apprentissages" (PIEA), or institutional policies of the evaluation of learning. This report provides a synthesis of evaluations of the PIEA conducted by the province's Commission on the…

  8. 75 FR 25319 - Agency Information Collection (Survey of Satisfaction With the Disability Evaluation System (DES...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900--New (DES)] Agency Information Collection (Survey of Satisfaction With the Disability Evaluation System (DES)) Activities Under OMB Review AGENCY...).'' SUPPLEMENTARY INFORMATION: Title: Survey of Satisfaction with the Disability Evaluation System (DES). OMB...

  9. CO2 laser irradiation enhances CaF2 formation and inhibits lesion progression on demineralized dental enamel-in vitro study.

    PubMed

    Zancopé, Bruna R; Rodrigues, Lívia P; Parisotto, Thais M; Steiner-Oliveira, Carolina; Rodrigues, Lidiany K A; Nobre-dos-Santos, Marinês

    2016-04-01

    This study evaluated if Carbon dioxide (CO2) (λ 10.6 μm) laser irradiation combined with acidulated phosphate fluoride gel application (APF gel) enhances "CaF2" uptake by demineralized enamel specimens (DES) and inhibits enamel lesion progression. Thus, two studies were conducted and DES were subjected to APF gel combined or not with CO2 laser irradiation (11.3 or 20.0 J/cm(2), 0.4 or 0.7 W) performed before, during, or after APF gel application. In study 1, 165 DES were allocated to 11 groups. Fluoride as "CaF2 like material" formed on enamel was determined in 100 DES (n = 10/group), and the surface morphologies of 50 specimens were evaluated by scanning electron microscopy (SEM) before and after "CaF2" extraction. In study 2, 165 DES (11 groups, n = 15), subjected to the same treatments as in study 1, were further subjected to a pH-cycling model to simulate a high cariogenic challenge. The progression of demineralization in DES was evaluated by cross-sectional microhardness and polarized light microscopy analyses. Laser at 11.3 J/cm(2) applied during APF gel application increased "CaF2" uptake on enamel surface. Laser irradiation and APF gel alone arrested the lesion progression compared with the control (p < 0.05). Areas of melting, fusion, and cracks were observed. CO2 laser irradiation, combined with a single APF application enhanced "CaF2" uptake on enamel surface and a synergistic effect was found. However, regarding the inhibition of caries lesion progression, no synergistic effect could be demonstrated. In conclusion, the results have shown that irradiation with specific laser parameters significantly enhanced CaF2 uptake by demineralized enamel and inhibited lesion progression.

  10. When to use discrete event simulation (DES) for the economic evaluation of health technologies? A review and critique of the costs and benefits of DES.

    PubMed

    Karnon, Jonathan; Haji Ali Afzali, Hossein

    2014-06-01

    Modelling in economic evaluation is an unavoidable fact of life. Cohort-based state transition models are most common, though discrete event simulation (DES) is increasingly being used to implement more complex model structures. The benefits of DES relate to the greater flexibility around the implementation and population of complex models, which may provide more accurate or valid estimates of the incremental costs and benefits of alternative health technologies. The costs of DES relate to the time and expertise required to implement and review complex models, when perhaps a simpler model would suffice. The costs are not borne solely by the analyst, but also by reviewers. In particular, modelled economic evaluations are often submitted to support reimbursement decisions for new technologies, for which detailed model reviews are generally undertaken on behalf of the funding body. This paper reports the results from a review of published DES-based economic evaluations. Factors underlying the use of DES were defined, and the characteristics of applied models were considered, to inform options for assessing the potential benefits of DES in relation to each factor. Four broad factors underlying the use of DES were identified: baseline heterogeneity, continuous disease markers, time varying event rates, and the influence of prior events on subsequent event rates. If relevant, individual-level data are available, representation of the four factors is likely to improve model validity, and it is possible to assess the importance of their representation in individual cases. A thorough model performance evaluation is required to overcome the costs of DES from the users' perspective, but few of the reviewed DES models reported such a process. More generally, further direct, empirical comparisons of complex models with simpler models would better inform the benefits of DES to implement more complex models, and the circumstances in which such benefits are most likely.

  11. Industrial laser welding evaluation study

    NASA Technical Reports Server (NTRS)

    Hella, R.; Locke, E.; Ream, S.

    1974-01-01

    High power laser welding was evaluated for fabricating space vehicle boosters. This evaluation was made for 1/4 in. and 1/2 in. aluminum (2219) and 1/4 in. and 1/2 in. D6AC steel. The Avco HPL 10 kW industrial laser was used to perform the evaluation. The objective has been achieved through the completion of the following technical tasks: (1) parameter study to optimize welding and material parameters; (2) preparation of welded panels for MSFC evaluation; and (3) demonstration of the repeatability of laser welding equipment. In addition, the design concept for a laser welding system capable of welding large space vehicle boosters has been developed.

  12. Le Laser A Argon Ionise : Applications Therapeutiques

    NASA Astrophysics Data System (ADS)

    Brunetaud, J. M.; Mosquet, L.; Mordon, S.; Rotteleur, G.

    1984-03-01

    Le laser a argon ionise est un laser a emission continue, reglee en general en multiraies de 487 a 544 nm. Le rayonnement de ce laser est bien absorbe par les tissus vivants, avec une action preferentielle au niveau des pigments rouges (hemoglobine, myoglobine) et noirs (melanine). Le laser a argon est princi-palement utilise en therapeutique pour ses effets thermiques : en fonction du choix des parametres (puissance optique, surface exposee, temps d'exposition) on peut obtenir une coagulation (temperature optimale au niveau des tissus 60° - 80°) ou une volatisation (temperature superieure a 100°). Si la zone volatilisee est tres etroite (inferieure a 0,5 mm) on obtient un effet de coupe. Par rapport aux deux autres lasers egalement utilises pour leurs effets thermiques (CO2 et Nd. YAG) l'argon a des effets intermediaires : la coagulation sera plus superficielle qu'avec le Nd. YAG et la volatisation plus profonde qu'avec le CO2. Lors de la coupe, la necrose sur les berges sera egalement plus importante qu'avec le CO2.

  13. Evaluation d'un scenario d'apprentissage favorisant la mobilisation des habiletes reliees au processus d'enquete

    NASA Astrophysics Data System (ADS)

    Blanchard, Samuel F. J.

    Les resultats au Programme international pour le suivi des acquis des eleves (PISA) demontrent que les jeunes neobrunswickois francophones se classent b un niveau significativement inferieur comparaiivement aux eleves anglophones du Nouveau-Brunswick, aux eleves des autres provinces canadiennes et se classent sous la moyenne internationale de tous les pays participants quant b la culture scientifique. L'evaluation de cette culture scientifique est basee sur une serie de savoirs, de savoir-faire et de savoir-etre reliee au processus d'enquete scolaire. Le processus d'enquete scolaire est une approche b l'apprentissage ou les eleves effectuent des recherches d'informations, discutent d'idees et entreprennent des investigations pour augmenter leur comprehension d'un probleme ou d'un sujet. Les recherches demontrent que le processus d'enquete scolaire est rarement une composante pedagogique importante de la salle de classe et les recherches portant sur l'implantation du processus d'enquete scolaire recommandent de rendre ce dernier plus accessible aux enseignantes et aux enseignants. Afin de rendre le processus d'enquete plus accessible aux enseignantes et aux enseignants, notre recherche porte sur l'evaluation de la valeur pedagogique d'un scenario d'apprentissage (PhaRoboS) concu specialement pour creer un environnement dans lequel les eleves auront plusieurs occasions a mobiliser les habiletes reliees au processus d'enquete. Les retombees de cette evaluation nous permettront d'offrir des pistes de remediations afin d'aider plus d'enseignantes et d'enseignants b creer un environnement dans lequel les eleves auront plusieurs occasions b mobiliser les habiletes reliees au processus d'enquete. Cette evaluation s'est faite a partir d'une methodologie inspiree de l'evaluation pour fin d'amelioration d'un objet pedagogique. L'analyse des donnees qualitatives recueillies aupres des eleves et de leur enseignante d'une ecole francophone du Nouveau-Brunswick semble montrer que

  14. Pulsed-laser capabilities at the Laser-Hardened Materials Evaluation Laboratory (LHMEL)

    NASA Astrophysics Data System (ADS)

    Royse, Robert W.; Seibert, Daniel B., II; Lander, Michael L.; Eric, John J.

    2000-08-01

    Pulsed laser capabilities at the Laser Hardened Material Evaluation Laboratory are described relevant to optical coupling, impulse generation and laser propulsion. Capabilities of the Nd:Glass laser are presented as well as supporting test systems.

  15. Laser interference effect evaluation method based on character of laser-spot and image feature

    NASA Astrophysics Data System (ADS)

    Tang, Jianfeng; Luo, Xiaolin; Wu, Lingxia

    2016-10-01

    Evaluating the laser interference effect to CCD objectively and accurately has great research value. Starting from the change of the image's feature before and after interference, meanwhile, considering the influence of the laser-spot distribution character on the masking degree of the image feature information, a laser interference effect evaluation method based on character of laser-spot and image feature was proposed. It reflected the laser-spot distribution character using the distance between the center of the laser-spot and center of the target. It reflected the change of the global image feature using the changes of image's sparse coefficient matrix, which was obtained by the SSIM-inspired orthogonal matching pursuit (OMP) sparse coding algorithm. What's more, the assessment method reflected the change of the local image feature using the changes of the image's edge sharpness, which could be obtained by the change of the image's gradient magnitude. Taken together, the laser interference effect can be evaluated accurately. In terms of the laser interference experiment results, the proposed method shows good rationality and feasibility under the disturbing condition of different laser powers, and it can also overcome the inaccuracy caused by the change of the laser-spot position, realizing the evaluation of the laser interference effect objectively and accurately.

  16. Dynamique de nanobulles et nanoplasmas generes autour de nanoparticules plasmoniques irradiees par des impulsions ultracourtes

    NASA Astrophysics Data System (ADS)

    Dagallier, Adrien

    L'emergence des lasers a impulsion ultrabreves et des nanotechnologies a revolutionne notre perception et notre maniere d'interagir avec l'infiniment petit. Les gigantesques intensites generees par ces impulsions plus courtes que les temps de relaxation ou de diffusion du milieu irradie induisent de nombreux phenomenes non-lineaires, du doublement de frequence a l'ablation, dans des volumes de dimension caracteristique de l'ordre de la longueur d'onde du laser. En biologie et en medecine, ces phenomenes sont utilises a des fins d'imagerie multiphotonique ou pour detruire des tissus vivants. L'introduction de nanoparticules plasmoniques, qui concentrent le champ electromagnetique incident dans des regions de dimensions nanometriques, jusqu'a une fraction de la longueur d'onde, amplifie les phenomenes non-lineaires tout en offrant un controle beaucoup plus precis de la deposition d'energie, ouvrant la voie a la detection de molecules individuelles en solution et a la nanochirurgie. La nanochirurgie repose principalement sur la formation d'une bulle de vapeur a proximite d'une membrane cellulaire. Cette bulle de vapeur perce la membrane de maniere irreversible,entrainant la cellule a sa mort, ou la perturbe temporairement, ce qui permet d'envisager de faire penetrer dans la cellule des medicaments ou des brins d'ADN pour de la therapie genique. C'est principalement la taille de la bulle qui va decider de l'issue de l'irradiation laser. Il est donc necessaire de controler finement les parametres du laser et la geometrie de la nanoparticule afin d'atteindre l'objectif fixe. Le moyen le plus direct a l'heure actuelle de valider un ensemble de conditions experimentales est de realiser l'experience en laboratoire,ce qui est long et couteux. Les modeles de dynamique de bulle existants ne prennent pas en compte les parametres de l'irradiation et ajustent souvent leurs conditions initiales a partir de leurs mesures experimentales, ce qui limite la portee du modele au cas pour

  17. Caractérisation expérimentale et modélisation numérique des propriétés spectroscopiques d'absorbants saturables pour le déclenchement passif de laser verre erbium

    NASA Astrophysics Data System (ADS)

    Girard, S.; Shcherbitsky, V.; Fromager, M.; Aït Ameur, K.; Moncorgé, R.; Ferrand, B.; Montagne, J.

    2002-06-01

    Une comparaison entre différents absorbants saturables (LMA, MALO, ZnS et ZnSe dopés Col^+ et ZnSe dopé Cr^{2+}) utilisables comme interrupteur optique passif pour déclencher les sources lasers verre erbium à 1.53 μm est présentée. Des expériences de saturation en simple passage sont interprétées en tenant compte de la distribution spatiale et temporelle du laser de pompe. Cette technique permet d'obtenir des sections efficaces de saturation effectives fiables et indépendantes des conditions de mesure sans introduire artificiellement d'absorption dans l'état excité qui, en principe, n'existe pas dans ce type de système contrairement aux études effectuées jusqu'ici sur ces matériaux.

  18. Comparative hazard evaluation of near-infrared diode lasers.

    PubMed

    Marshall, W J

    1994-05-01

    Hazard evaluation methods from various laser protection standards differ when applied to extended-source, near-infrared lasers. By way of example, various hazard analyses are applied to laser training systems, which incorporate diode lasers, specifically those that assist in training military or law enforcement personnel in the proper use of weapons by simulating actual firing by the substitution of a beam of near-infrared energy for bullets. A correct hazard evaluation of these lasers is necessary since simulators are designed to be directed toward personnel during normal use. The differences among laser standards are most apparent when determining the hazard class of a laser. Hazard classification is based on a comparison of the potential exposures with the maximum permissible exposures in the 1986 and 1993 versions of the American National Standard for the Safe Use of Lasers, Z136.1, and the accessible emission limits of the federal laser product performance standard. Necessary safety design features of a particular system depend on the hazard class. The ANSI Z136.1-1993 standard provides a simpler and more accurate hazard assessment of low-power, near-infrared, diode laser systems than the 1986 ANSI standard. Although a specific system is evaluated, the techniques described can be readily applied to other near-infrared lasers or laser training systems.

  19. Evaluation d’une grille de supervision des laboratoires des leishmanioses cutanées au Maroc

    PubMed Central

    El Mansouri, Bouchra; Amarir, Fatima; Hajli, Yamina; Fellah, Hajiba; Sebti, Faiza; Delouane, Bouchra; Sadak, Abderrahim; Adlaoui, El Bachir; Rhajaoui, Mohammed

    2017-01-01

    Introduction Afin d’évaluer une grille de contrôle standardisée de laboratoire de diagnostic des leishmanioses, comme nouveau outil de supervision. Méthodes Un essai pilote a été pratiqué sur sept laboratoires provinciaux, appartenant à quatre provinces au Maroc, en suivant l’évolution de leurs performances tous les deux ans, entre l’année 2006 et 2014. Cette étude détaille la situation des laboratoires provinciaux avant et après la mise en œuvre de la grille de supervision. Au total vingt et une grille sont analysées. Résultats En 2006, les résultats ont montré clairement une insuffisance des performances des laboratoires: besoin en formation (41.6%), personnel pratiquant le prélèvement cutané (25%), pénurie en matériels et réactifs (65%), gestions documentaire et local non conformes (85%). Différentes actions correctives ont été menées par le Laboratoire National de Référence des Leishmanioses (LNRL) durant la période d’étude. En 2014, le LNRL a enregistré une nette amélioration des performances des laboratoires. Les besoins en matière de formation, qualité du prélèvement, dotation en matériels et réactifs ont été comblés et une coordination efficace s’est établie entre le LNRL et les laboratoires provinciaux. Conclusion Ceci montre l'efficacité de la grille comme outil de supervision de grande qualité, et comme pierre angulaire de tout progrès qui doit être obtenu dans les programmes de lutte contre les leishmanioses. PMID:29187922

  20. Characterization of the canine desmin (DES) gene and evaluation as a candidate gene for dilated cardiomyopathy in the Dobermann.

    PubMed

    Stabej, Polona; Imholz, Sandra; Versteeg, Serge A; Zijlstra, Carla; Stokhof, Arnold A; Domanjko-Petric, Aleksandra; Leegwater, Peter A J; van Oost, Bernard A

    2004-10-13

    Canine-dilated cardiomyopathy (DCM) in dogs is a disease of the myocardium associated with dilatation and impaired contraction of the ventricles and is suspected to have a genetic cause. A missense mutation in the desmin gene (DES) causes DCM in a human family. Human DCM closely resembles the canine disease. In the present study, we evaluated whether DES gene mutations are responsible for DCM in Dobermann dogs. We have isolated bacterial artificial chromosome clones (BACs) containing the canine DES gene and determined the chromosomal location by fluorescence in situ hybridization (FISH). Using data deposited in the NCBI trace archive and GenBank, the canine DES gene DNA sequence was assembled and seven single nucleotide polymorphisms (SNPs) were identified. From the canine DES gene BAC clones, a polymorphic microsatellite marker was isolated. The microsatellite marker and four informative desmin SNPs were typed in a Dobermann family with frequent DCM occurrence, but the disease phenotype did not associate with a desmin haplotype. We concluded that mutations in the DES gene do not play a role in Dobermann DCM. Availability of the microsatellite marker, SNPs and DNA sequence reported in this study enable fast evaluation of the DES gene as a DCM candidate gene in other dog breeds with DCM occurrence.

  1. Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.

    PubMed

    Mordon, Serge; Eymard-Maurin, Anne Françoise; Wassmer, Benjamin; Ringot, Jean

    2007-01-01

    The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 1064-nm Nd:YAG laser versus a continuous 980-nm diode laser. A pulsed 1064-nm Nd:YAG (Smart-Lipo; Deka, Italy) and a CW 980-nm diode laser (Pharaon, Osyris, France) were evaluated at different energy settings for lipolysis on the thighs of a fresh cadaver. The lasers were coupled to a 600-microm optical fiber inserted in a 1-mm diameter cannula. Biopsy specimens were taken on irradiated and non-irradiated areas. Hematoxylin-erythrosin-safran staining and immunostaining (anti-PS100 polyclonal antibody) were performed to identify fat tissue damage. In the absence of laser exposures (control specimens), cavities created by cannulation were seen; adipocytes were round in appearance and not deflated. At low energy settings, tumescent adipocytes were observed. At higher energy settings, cytoplasmic retraction, disruption of membranes, and heat-coagulated collagen fibers were noted; coagulated blood cells were also present. For the highest energy settings, carbonization of fat tissue involving fibers and membranes was clearly seen. For equivalent energy settings, 1064-nm and 980-nm wavelengths gave similar histologic results. Laser lipolysis is a relatively new technique that is still under development. Our histologic findings suggest several positive benefits of the laser, including skin retraction and a reduction in intraoperative bleeding. The interaction of the laser with the tissue is similar at 980 nm and 1064 nm with the same energy settings. Because higher volumes of fat are removed with higher total energy, a high-power 980-nm diode laser could offer an interesting alternative to the 1064-nm Nd

  2. Impact de la preparation des anodes crues et des conditions de cuisson sur la fissuration dans des anodes denses

    NASA Astrophysics Data System (ADS)

    Amrani, Salah

    La fabrication de l'aluminium est realisee dans une cellule d'electrolyse, et cette operation utilise des anodes en carbone. L'evaluation de la qualite de ces anodes reste indispensable avant leur utilisation. La presence des fissures dans les anodes provoque une perturbation du procede l'electrolyse et une diminution de sa performance. Ce projet a ete entrepris pour determiner l'impact des differents parametres de procedes de fabrication des anodes sur la fissuration des anodes denses. Ces parametres incluent ceux de la fabrication des anodes crues, des proprietes des matieres premieres et de la cuisson. Une recherche bibliographique a ete effectuee sur tous les aspects de la fissuration des anodes en carbone pour compiler les travaux anterieurs. Une methodologie detaillee a ete mise au point pour faciliter le deroulement des travaux et atteindre les objectifs vises. La majorite de ce document est reservee pour la discussion des resultats obtenus au laboratoire de l'UQAC et au niveau industriel. Concernant les etudes realisees a l'UQAC, une partie des travaux experimentaux est reservee a la recherche des differents mecanismes de fissuration dans les anodes denses utilisees dans l'industrie d'aluminium. L'approche etait d'abord basee sur la caracterisation qualitative du mecanisme de la fissuration en surface et en profondeur. Puis, une caracterisation quantitative a ete realisee pour la determination de la distribution de la largeur de la fissure sur toute sa longueur, ainsi que le pourcentage de sa surface par rapport a la surface totale de l'echantillon. Cette etude a ete realisee par le biais de la technique d'analyse d'image utilisee pour caracteriser la fissuration d'un echantillon d'anode cuite. L'analyse surfacique et en profondeur de cet echantillon a permis de voir clairement la formation des fissures sur une grande partie de la surface analysee. L'autre partie des travaux est basee sur la caracterisation des defauts dans des echantillons d'anodes crues

  3. Diode laser prostatectomy (VLAP): initial canine evaluation

    NASA Astrophysics Data System (ADS)

    Kopchok, George E.; Verbin, Chris; Ayres, Bruce; Peng, Shi-Kaung; White, Rodney A.

    1995-05-01

    This study evaluated the acute and chronic effects of diode laser (960 nm) prostatectomy using a Prolase II fiber in a canine model (n equals 5). The laser fiber consists of a 1000 um quartz fiber which reflects a cone of laser energy, at 45 degree(s) to the axis of the fiber, into the prostatic urethra (Visual Laser Ablation of Prostate). Perineal access was used to guide a 15.5 Fr cystoscope to the level of the prostate. Under visual guidance and continual saline irrigation, 60 watts of laser power was delivered for 60 seconds at 3, 9, and 12 o'clock and 30 seconds at the 6 o'clock (posterior) positions for a total energy fluence of 12,600 J. One prostate received an additional 60 second exposure at 3 and 9 o'clock for a total fluence of 19,800 J. The prostates were evaluated at one day (n equals 1) and 8 weeks (n equals 4). The histopathology of laser effects at one day show areas of necrosis with loss of glandular structures and stromal edema. Surrounding this area was a zone of degenerative glandular structures extending up to 17.5 mm (cross sectional diameter). The histopathology of the 8 week laser treated animals demonstrated dilated prostatic urethras with maximum cross- sectional diameter of 23.4 mm (mean equals 18.5 +/- 3.9 mm). This study demonstrates the effectiveness of diode laser energy for prostatic tissue coagulation and eventual sloughing. The results also demonstrate the safety of diode laser energy, with similar tissue response as seen with Nd:YAG laser, for laser prostatectomy.

  4. Laser Doppler flowmetry evaluation of gingival recovery response after laser treatment

    NASA Astrophysics Data System (ADS)

    Todea, Carmen; Cânjǎu, Silvana; Dodenciu, Dorin; Miron, Mariana I.; Tudor, Anca; Bǎlǎbuc, Cosmin

    2013-06-01

    This study was performed in order to evaluate in vivo the applicability of Laser Doppler Flowmetry (LDF) in recording the gingival blood flow and to assess the changes of gingival blood flow following gingival reshaping performed with Er:YAG and 980 nm diode lasers. The LDF evaluation was performed on 20 anterior teeth, which underwent reshaping of gingiva, corresponding to 5 female patients (4 anterior teeth/patient), aged between 20 and 35. One part of the mouth was treated with Er:YAG laser (LP, VLP modes, 140 - 250 mJ, 10 - 20 Hz, using cylindrical sapphire tips) and other part with 980 nm diode laser (CW, 4 W, contact mode and saline solution cooling). The gingival blood flow was monitored using a MoorLab laser Doppler equipment (Moor Instruments Ltd., Axminster, UK) with a straight optical probe, MP3b, 10 mm. The data were processed using statistical analysis software SPSS v16.0.1. The investigation showed an evident decrease in perfusion for both areas in comparison with the baseline values 24 hours after treatment. The microvascular blood flow increased significantly after 7 days in both areas but mostly in diode area (p<0.001). After 14 days for the Er:YAG area the blood perfusion returned to the initial value. The results in diode area remained at a high level after 14 days. Both lasers proved efficiency in the surgical treatment of gingival tissue. Moreover, Laser Doppler Flowmetry is adequate for recording changes in gingival blood flow following periodontal surgery.

  5. Electromagnetic Gauge Study of Laser-Induced Shock Waves in Aluminium Alloys

    NASA Astrophysics Data System (ADS)

    Peyre, P.; Fabbro, R.

    1995-12-01

    The laser-shock behaviour of three industrial aluminum alloys has been analyzed with an Electromagnetic Gauge Method (EMV) for measuring the velocity of the back free surface of thin foils submitted to plane laser irradiation. Surface pressure, shock decay in depth and Hugoniot Elastic Limits (HEL) of the materials were investigated with increasing thicknesses of foils to be shocked. First, surface peak pressures values as a function of laser power density gave a good agreement with conventional piezoelectric quartz measurements. Therefore, comparison of experimental results with computer simulations, using a 1D hydrodynamic Lagrangian finite difference code, were also in good accordance. Lastly, HEL values were compared with static and dynamic compressive tests in order to estimate the effects of a very large range of strain rates (10^{-3} s^{-1} to 10^6 s^{-1}) on the mechanical properties of the alloys. Cet article fait la synthèse d'une étude récente sur la caractérisation du comportement sous choc-laser de trois alliages d'aluminium largement utilisés dans l'industrie à travers la méthode dite de la jauge électromagnétique. Cette méthode permet de mesurer les vitesses matérielles induites en face arrière de plaques d'épaisseurs variables par un impact laser. La mise en vitesse de plaques nous a permis, premièrement, de vérifier la validité des pressions d'impact superficielles obtenues en les comparant avec des résultats antérieurs obtenus par des mesures sur capteurs quartz. Sur des plaques d'épaisseurs croissantes, nous avons caractérisé l'atténuation des ondes de choc en profondeur dans les alliages étudiés et mesuré les limites d'élasticité sous choc (pressions d'Hugoniot) des alliages. Les résultats ont été comparés avec succès à des simulations numériques grâce à un code de calcul monodimensionnel Lagrangien. Enfin, les valeurs des pressions d'Hugoniot mesurées ont permis de tracer l'évolution des contraintes d

  6. Déprescription des agonistes des récepteurs des benzodiazépines

    PubMed Central

    Pottie, Kevin; Thompson, Wade; Davies, Simon; Grenier, Jean; Sadowski, Cheryl A.; Welch, Vivian; Holbrook, Anne; Boyd, Cynthia; Swenson, Robert; Ma, Andy; Farrell, Barbara

    2018-01-01

    Résumé Objectif Formuler des lignes directrices fondées sur les données probantes visant à aider les cliniciens à décider du moment et de la façon sécuritaire de réduire la dose des agonistes des récepteurs des benzodiazépines (BZRA) pour mettre fin au traitement; se concentrer sur le niveau le plus élevé des données disponibles et obtenir les commentaires des professionnels de première ligne durant le processus de rédaction, de révision et d’adoption des lignes directrices. Méthodes L’équipe comptait 8 cliniciens (1 médecin de famille, 2 psychiatres, 1 psychologue clinique, 1 pharmacologue clinique, 2 pharmaciennes cliniques et 1 gériatre) et une spécialiste de la méthodologie; les membres ont divulgué tout conflit d’intérêts. Nous avons eu recours à un processus systématique, y compris l’approche GRADE (Grading of Recommendations Assessment, Development and Evaluation) pour formuler les lignes directrices. Les données ont été générées par une revue systématique d’études portant sur la déprescription des BZRA contre l’insomnie, de même que par une revue des revues sur les torts liés à la poursuite du traitement par BZRA et des synthèses narratives sur les préférences des patients et les répercussions sur les ressources. Ces données et le score GRADE de qualité des données ont servi à formuler les recommandations. L’équipe a peaufiné le texte sur le contenu et les recommandations des lignes directrices par consensus et a synthétisé les considérations cliniques afin de répondre aux questions des cliniciens de première ligne. Une version préliminaire des lignes directrices a été révisée par les cliniciens et les intervenants. Recommandations Nous recommandons d’offrir la déprescription (réduction lente de la dose) des BZRA à tous les patients âgés (≥ 65 ans) sous un BZRA, sans égard à la durée de l’usage, et suggérons d’offrir la déprescription (réduction lente de la dose)

  7. Laser Safety Manual for DREO

    DTIC Science & Technology

    1993-11-01

    milieu de travail securitaire dans les laboratoires de recherche utilisant de la radiation laser. L ’"American National Standard for the Safe Use of...d6fense nationale de poursuites l ~gales. i~i. I I EXECUTIVE SUMMARY Laser beams are currently used for some R&D activities at DREO. As laser radiation...par un appared as described in CFAO 66-4. must be strictly observed, laser peut provoquer des br-tilures de la reline et de la peau . Les mesures de

  8. Evaluation of a satellite laser ranging technique using pseudonoise code modulated laser diodes

    NASA Technical Reports Server (NTRS)

    Ball, Carolyn Kay

    1987-01-01

    Several types of Satellite Laser Ranging systems exist, operating with pulsed, high-energy lasers. The distance between a ground point and an orbiting satellite can be determined to within a few centimeters. A new technique substitutes pseudonoise code modulated laser diodes, which are much more compact, reliable and less costly, for the lasers now used. Since laser diode technology is only now achieving sufficiently powerful lasers, the capabilities of the new technique are investigated. Also examined are the effects of using an avalanche photodiode detector instead of a photomultiplier tube. The influence of noise terms (including background radiation, detector dark and thermal noise and speckle) that limit the system range and performance is evaluated.

  9. Effect of pulsed laser light in patients with dry eye syndrome.

    PubMed

    Guilloto Caballero, S; García Madrona, J L; Colmenero Reina, E

    2017-11-01

    The objective of this study was to determine the clinical benefits of pulsed light therapy for the treatment of Dry Eye Syndrome (DES) due to the decrease in aqueous tear production (aqueous deficient DES) and/or excessive tear evaporation (evaporative DES) due to Meibomian Gland Dysfunction (MGD). A study was conducted on 72 eyes corresponding to 36 patients with DES. Out of these 72 eyes, 60 underwent refractive surgery (48 with femtosecond laser, 6 were operated with a mechanical microkeratome, and 6 with refractive photo-keratectomy[RPK], 6 treated with phacoemulsification, and 6 with no previous surgical treatment. Pulsed laser light (Intense Pulsed Light Regulated [IRPL ® ]) was use to stimulate the secretion of the Meibomian glands during 4 sessions, one every 15 days. Patients with aqueous deficient DES did not show any improvement. Eyes with no previous surgery and those treated with phacoemulsification and PRK had a favourable outcome. On the other hand, less conclusive results were observed in the eyes treated with excimer laser. This treatment could be very helpful to treat evaporative DES produced by MGD. On the other hand, it is not helpful for those cases related to an isolated damage in the aqueous phase, or the mucin phase. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Etude des phenomenes dynamiques ultrarapides et des caracteristiques impulsionnelles d'emission terahertz du supraconducteur YBCO

    NASA Astrophysics Data System (ADS)

    Savard, Stephane

    Les premieres etudes d'antennes a base de supraconducteurs a haute temperature critique emettant une impulsion electromagnetique dont le contenu en frequence se situe dans le domaine terahertz remontent a 1996. Une antenne supraconductrice est formee d'un micro-pont d'une couche mince supraconductrice sur lequel un courant continu est applique. Un faisceau laser dans le visible est focalise sur le micro-pont et place le supraconducteur dans un etat hors-equilibre ou des paires sont brisees. Grace a la relaxation des quasiparticules en surplus et eventuellement de la reformation des paires supraconductrices, nous pouvons etudier la nature de la supraconductivite. L'analyse de la cinetique temporelle du champ electromagnetique emis par une telle antenne terahertz supraconductrice s'est averee utile pour decrire qualitativement les caracteristiques de celle-ci en fonction des parametres d'operation tels que le courant applique, la temperature et la puissance d'excitation. La comprehension de l'etat hors-equilibre est la cle pour comprendre le fonctionnement des antennes terahertz supraconductrices a haute temperature critique. Dans le but de comprendre ultimement cet etat hors-equilibre, nous avions besoin d'une methode et d'un modele pour extraire de facon plus systematique les proprietes intrinseques du materiau qui compose l'antenne terahertz a partir des caracteristiques d'emission de celle-ci. Nous avons developpe une procedure pour calibrer le spectrometre dans le domaine temporel en utilisant des antennes terahertz de GaAs bombarde aux protons H+ comme emetteur et detecteur. Une fois le montage calibre, nous y avons insere une antenne emettrice dipolaire de YBa 2Cu3O7-delta . Un modele avec des fonctions exponentielles de montee et de descente du signal est utilise pour lisser le spectre du champ electromagnetique de l'antenne de YBa 2Cu3O7-delta, ce qui nous permet d'extraire les proprietes intrinseques de ce dernier. Pour confirmer la validite du modele

  11. Laser Safety Evaluation of the MILES and Mini MILES Laser Emitting Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AUGUSTONI, ARNOLD L.

    Laser safety evaluation and output emission measurements were performed (during October and November 2001) on SNL MILES and Mini MILES laser emitting components. The purpose, to verify that these components, not only meet the Class 1 (eye safe) laser hazard criteria of the CDRH Compliance Guide for Laser Products and 21 CFR 1040 Laser Product Performance Standard; but also meet the more stringent ANSI Std. z136.1-2000 Safe Use of Lasers conditions for Class 1 lasers that govern SNL laser operations. The results of these measurements confirmed that all of the Small Arms Laser Transmitters, as currently set (''as is''), meetmore » the Class 1 criteria. Several of the Mini MILES Small Arms Transmitters did not. These were modified and re-tested and now meet the Class 1 laser hazard criteria. All but one System Controllers (hand held and rifle stock) met class 1 criteria for single trigger pulls and all presented Class 3a laser hazard levels if the trigger is held (continuous emission) for more than 5 seconds on a single point target. All units were Class 3a for ''aided'' viewing. These units were modified and re-tested and now meet the Class 1 hazard criteria for both ''aided'' as well as ''unaided'' viewing. All the Claymore Mine laser emitters tested are laser hazard Class 1 for both ''aided'' as well as ''unaided'' viewing.« less

  12. Evaluation of the effect of a CO2 laser and fluoride on the reduction of carious lesions progression in primary teeth: an in vitro study

    NASA Astrophysics Data System (ADS)

    Zancopé, Bruna R.; Cesar, Marina M. C.; Rodrigues, Lidiany K. A.; Nobre-dos-Santos, Marinês

    2014-02-01

    This study aimed at investigating if CO2 laser irradiation (λ =10.6μm - 11.3 J/cm2) combined with fluoridated products, enhances the CaF2 formation on enamel surface and inhibits lesion progression of demineralized primary enamel. Thus, 135 demineralized primary enamel specimens (DES) were allocated to 9 groups (n=15) as follows: 1- DES only, 2- DES + pH cycling (control), 3- 1.23% acidulated phosphate fluoride gel (APF), 4- 1.23% fluoride foam (FF), 5- 5% fluoride varnish (FV), 6- CO2 Laser (L), 7 - Laser during APF application, 8-Laser during FF application and 9-Laser during FV application. Except for the demineralized enamel group, all specimens were submitted to a 7 day pH cycling regime. The knoop hardness number (KHN) was determined by cross-sectional microhardness analysis. After treatments application, three specimens of each group had their surface examined for CaF2 formation by scanning electron microscopy (SEM). The data was analyzed by ANOVA and Student's t-test (α= 0.05). Enamel mineral loss (ΔS) for groups 1 to 9 were respectively,(8,676.28+/-1,077.46b),(12,419.54+/-1,050.21a),(8,156.80+/-1,279.90b),(8,081.32+/-1,019.69b),(8,820.86+/-1,805. 99b),(8,723.45+/-1,167.14b),(9,003.17+/-796.90b),(8.229,03+/-961.25b),(9,023.32+/-1,1069b). The results showed statistically significant difference between control and all treatments groups (p<0.05). However there was no difference among them (p>0.05). SEM observations showed evidences of melting, fusion and calcium fluoride formation on enamel surface. In conclusion, laser irradiation alone or combined with fluoridated products inhibited lesion progression of demineralized primary enamel surface. However, no synergistic effect was observed when CO2 laser irradiation and fluoridated products application were combined.

  13. Comparison of a long-pulse Nd:YAG laser and a combined 585/1,064-nm laser for the treatment of acne scars: a randomized split-face clinical study.

    PubMed

    Min, Seong U K; Choi, Yu Sung; Lee, Dong Hun; Yoon, Mi Young; Suh, Dae Hun

    2009-11-01

    Nonablative laser is gaining popularity because of the low risk of complications, especially in patients with darker skin. To compare the efficacy and safety of a long-pulse neodymium-doped yttrium aluminium garnet (Nd:YAG) laser and a combined 585/1,064-nm laser for the treatment of acne scars. Nineteen patients with mild to moderate atrophic acne scars received four long-pulse Nd:YAG laser or combined 585/1,064-nm laser treatment sessions at fortnightly intervals. Treatments were administered randomly in a split-face manner. Acne scars showed mild to moderate improvement, with significant Echelle d'évaluation clinique des cicatrices d'acné (ECCA) score reductions, after both treatments. Although intermodality differences were not significant, combined 585/1,064-nm laser was more effective for deep boxcar scars. In patients with combined 585/1,064-nm laser-treated sides that improved more than long-pulse Nd:YAG laser-treated sides, ECCA scores were significantly lower for combined 585/1,064-nm laser treatment. Histologic evaluations revealed significantly greater collagen deposition, although there was no significant difference between the two modalities. Patient satisfaction scores concurred with physicians' evaluations. Both lasers ameliorated acne scarring with minimal downtime. In light of this finding, optimal outcomes might be achieved when laser treatment types are chosen after considering individual scar type and response.

  14. Vecteurs Singuliers des Theories des Champs Conformes Minimales

    NASA Astrophysics Data System (ADS)

    Benoit, Louis

    En 1984 Belavin, Polyakov et Zamolodchikov revolutionnent la theorie des champs en explicitant une nouvelle gamme de theories, les theories quantiques des champs bidimensionnelles invariantes sous les transformations conformes. L'algebre des transformations conformes de l'espace-temps presente une caracteristique remarquable: en deux dimensions elle possede un nombre infini de generateurs. Cette propriete impose de telles conditions aux fonctions de correlations qu'il est possible de les evaluer sans aucune approximation. Les champs des theories conformes appartiennent a des representations de plus haut poids de l'algebre de Virasoro, une extension centrale de l'algebre conforme du plan. Ces representations sont etiquetees par h, le poids conforme de leur vecteur de plus haut poids, et par la charge centrale c, le facteur de l'extension centrale, commune a toutes les representations d'une meme theorie. Les theories conformes minimales sont constituees d'un nombre fini de representations. Parmi celles-ci se trouvent des theories unitaires dont les representation forment la serie discrete de l'algebre de Virasoro; leur poids h a la forme h_{p,q}(m)=[ (p(m+1) -qm)^2-1] (4m(m+1)), ou p,q et m sont des entiers positifs et p+q<= m+1. L'entier m parametrise la charge centrale: c(m)=1 -{6over m(m+1)} avec n>= 2. Ces representations possedent un sous-espace invariant engendre par deux sous-representations avec h_1=h_{p,q} + pq et h_2=h_{p,q} + (m-p)(m+1-q) dont chacun des vecteurs de plus haut poids portent le nom de vecteur singulier et sont notes respectivement |Psi _{p,q}> et |Psi_{m-p,m+1-q}>. . Les theories super-conformes sont une version super-symetrique des theories conformes. Leurs champs appartiennent a des representation de plus haut poids de l'algebre de Neveu-Schwarz, une des deux extensions super -symetriques de l'algebre de Virasoro. Les theories super -conformes minimales possedent la meme structure que les theories conformes minimales. Les representations

  15. Developpement d'un montage simulant l'erosion par la pluie pour l'evaluation des revetements glaciophobes dans le domaine aerospatial

    NASA Astrophysics Data System (ADS)

    Tremblay, Sarah-Eve

    Ce memoire presente le developpement d’un montage simulant l’erosion par la pluie afin d’effectuer l’evaluation de differents revetements glaciophobes dans le domaine aerospatial. Bien que plusieurs revetements presentent une bonne efficacite a reduire l’adherence et/ou l’accumulation de glace, ils ne repondent pas necessairement aux normes de resistance a l’erosion simulee par les gouttes de pluie les frappant a grande vitesse. Il n’existe qu’une installation en Amerique du Nord offrant un service d’essai qui evalue la resistance a l’erosion par la pluie suivant les normes aerospatiales. Etant l’unique institution pouvant faire la certification de peintures utilisees sur les avions en ce qui a trait a l’erosion par la pluie, ce service est donc difficile d’acces et couteux. Le laboratoire international des materiaux antigivre (LIMA) a developpe un essai plus rapide et moins couteux, facilitant ainsi le developpement de revetements glaciophobes devant resister a l’erosion par la pluie. Dans cette etude, le developpement du montage d’erosion par la pluie effectue au laboratoire des materiaux antigivre (LIMA) est presente. En particulier, des essais sur quatre (4) revetements dont la resistance a l’erosion est connue, et sur trois revetements industriels, ont ete effectues afin d’ajuster les differents parametres du montage comme la pression et la temperature de l’eau ainsi que la robustesse du montage. Ensuite, des essais de sensibilite et de reproductibilite des resultats ont egalement ete effectues pour fin de validation du montage et du protocole experimental. Pour ce faire, le montage de type jet d’eau developpe consiste principalement en une pompe a haute pression qui projette un jet d’eau continu passant par les orifices d’un disque tournant. Cette operation permet de generer une goutte de pluie simulee qui est projetee sur un echantillon de revetement statique. L’essai est base sur la norme standard ASTM (Liquid

  16. Airborne Laser Systems Testing and Analysis (essals et analyse des systemes laser embarques)

    DTIC Science & Technology

    2010-04-01

    of Surface/ Paints Reflection Properties (PILASTER targets); • PILASTER Sensors Testing and Calibration; • LOAS Laser System Testing; and • Test...PILASTER targets candidate paints and materials), a Laser Scatter-meter (LSM) was built. To briefly summarise the fundamental concepts involved...Green Painted Target. 7.6.3 Laser Beam Misalignment with Respect to the Beam-Expander Support For measuring the beam misalignment, the beam expander

  17. Evaluation d'une approche pedagogique respectant les facons d'apprendre des filles en sciences et en TIC en 9e annee au Nouveau-Brunswick

    NASA Astrophysics Data System (ADS)

    Lirette-Pitre, Nicole T.

    2009-07-01

    La reussite scolaire des filles les amene de plus en plus a poursuivre une formation postsecondaire et a exercer des professions qui demandent un haut niveau de connaissances et d'expertise scientifique. Toutefois, les filles demeurent toujours tres peu nombreuses a envisager une carriere en sciences (chimie et physique), en ingenierie ou en TIC (technologie d'information et de la communication), soit une carriere reliee a la nouvelle economie. Pour plusieurs filles, les sciences et les TIC ne sont pas des matieres scolaires qu'elles trouvent interessantes meme si elles y reussissent tres bien. Ces filles admettent que leurs experiences d'apprentissage en sciences et en TIC ne leur ont pas permis de developper un interet ni de se sentir confiante en leurs habiletes a reussir dans ces matieres. Par consequent, peu de filles choisissent de poursuivre leurs etudes postsecondaires dans ces disciplines. La theorie sociocognitive du choix carriere a ete choisie comme modele theorique pour mieux comprendre quelles variables entrent en jeu lorsque les filles choisissent leur carriere. Notre etude a pour objet la conception et l'evaluation de l'efficacite d'un materiel pedagogique concu specifiquement pour ameliorer les experiences d'apprentissage en sciences et en TIC des filles de 9e annee au Nouveau-Brunswick. L'approche pedagogique privilegiee dans notre materiel a mis en oeuvre des strategies pedagogiques issues des meilleures pratiques que nous avons identifiees et qui visaient particulierement l'augmentation du sentiment d'auto-efficacite et de l'interet des filles pour ces disciplines. Ce materiel disponible par Internet a l'adresse http://www.umoncton.ca/lirettn/scientic est directement en lien avec le programme d'etudes en sciences de la nature de 9e annee du Nouveau-Brunswick. L'evaluation de l'efficacite de notre materiel pedagogique a ete faite selon deux grandes etapes methodologiques: 1) l'evaluation de l'utilisabilite et de la convivialite du materiel et 2

  18. A comparative evaluation: Oral leukoplakia surgical management using diode laser, CO2 laser, and cryosurgery.

    PubMed

    Natekar, Madhukar; Raghuveer, Hosahallli-Puttaiah; Rayapati, Dilip-Kumar; Shobha, Eshwara-Singh; Prashanth, Nagesh-Tavane; Rangan, Vinod; Panicker, Archana G

    2017-06-01

    The comparatively evaluate the three surgical treatment modalities namely cryosurgery, diode and CO2 laser surgery in terms of healing outcomes on the day of surgery, first and second week post operatively and recurrence at the end of 18 months was assessed. Thirty selected patients were divided randomly into three groups. Each group comprising of ten patients were subjected to one of the three modalities of treatment namely cryosurgery, diode laser or CO2 laser surgery for ablation of OL. Obtained data was analyzed using mainly using Chi-square and Anova tests. Study showed statistical significant differences (p > 0.05) for evaluation parameters like pain, edema and scar. The parameters like infection, recurrence, bleeding showed no statistical significance. Pain was significantly higher in CO2 laser surgery group as compared with diode laser group. There was no recurrence observed at the end of the 6 months follow up period in all the three study groups. Observations from the study highlights that all three surgical modalities used in this study were effective for treatment of OL, and the overall summation of the results of the study showed that laser therapy (CO2 and Diode) seems to offer better clinically significant results than cryotherapy. Key words: Oral premalignant lesion, leukoplakia, cryosurgery, CO2 laser surgery, diode laser surgery.

  19. Etude de l'amelioration de la qualite des anodes par la modification des proprietes du brai

    NASA Astrophysics Data System (ADS)

    Bureau, Julie

    La qualite des anodes produites se doit d'etre bonne afin d'obtenir de l'aluminium primaire tout en reduisant le cout de production du metal, la consommation d'energie et les emissions environnementales. Or, l'obtention des proprietes finales de l'anode necessite une liaison satisfaisante entre le coke et le brai. Toutefois, la matiere premiere actuelle n'assure pas forcement la compatibilite entre le coke et le brai. Une des solutions les plus prometteuses, pour ameliorer la cohesion entre ces deux materiaux, est la modification des proprietes du brai. L'objectif de ce travail consiste a modifier les proprietes du brai par l'ajout d'additifs chimiques afin d'ameliorer la mouillabilite du coke par le brai modifie pour produire des anodes de meilleure qualite. La composition chimique du brai est modifiee en utilisant des tensioactifs ou agents de modification de surface choisis dans le but d'enrichir les groupements fonctionnels susceptibles d'ameliorer la mouillabilite. L'aspect economique, l'empreinte environnementale et l'impact sur la production sont consideres dans la selection des additifs chimiques. Afin de realiser ce travail, la methodologie consiste a d'abord caracteriser les brais non modifies, les additifs chimiques et les cokes par la spectroscopie infrarouge a transformee de Fourier (FTIR) afin d'identifier les groupements chimiques presents. Puis, les brais sont modifies en ajoutant un additif chimique afin de possiblement modifier ses proprietes. Differentes quantites d'additif sont ajoutees afin d'examiner l'effet de la variation de la concentration sur les proprietes du brai modifie. La methode FTIR permet d'evaluer la composition chimique des brais modifies afin de constater si l'augmentation de la concentration d'additif enrichit les groupements fonctionnels favorisant l'adhesion coke/brai. Ensuite, la mouillabilite du coke par le brai est observee par la methode goutte- sessile. Une amelioration de la mouillabilite par la modification a l'aide d

  20. Evaluation of 3-D laser scanning equipment : 2016 interim report.

    DOT National Transportation Integrated Search

    2017-05-01

    As a follow-up to ICT Project R27-030, Evaluation of 3-D Laser Scanning, this report provides findings of an evaluation of 3-D laser : scanning equipment to determine the tangible costs versus benefits and the manpower savings realized by using the e...

  1. Evaluation of 3-D Laser Scanning Equipment : 2018 Final Report

    DOT National Transportation Integrated Search

    2018-05-01

    As a follow-up to ICT Project R27-030, Evaluation of 3-D Laser Scanning, this report provides findings of an evaluation of 3-D laser scanning equipment to determine the tangible costs versus benefits and the manpower savings realized by using the equ...

  2. Evaluation of a laser road surface tester.

    DOT National Transportation Integrated Search

    1995-01-01

    The purpose of this study was to evaluate the accuracy and usefulness of pavement distress data derived from a laser road surface tester (RST) operating on Virginia's interstate highway system. The evaluation was conducted by comparing rut depth, rou...

  3. Controle optique de qubits lies a des centres isoelectroniques d'azote dans le GaAs

    NASA Astrophysics Data System (ADS)

    Ethier-Majcher, Gabriel

    Le traitement de l'information quantique est un domaine de recherche actuellement en pleine effervescence car il laisse entrevoir une revolution dans notre facon de traiter et d'echanger de l'information. D'une part, l'ordinateur quantique promet de resoudre des problemes comme la factorisation d'un polynome de facon beaucoup plus efficace qu'un ordinateur classique. D'autre part, les communications quantiques promettent l'echange d'information de facon fondamentalement inviolable. Afin de tirer pleinement profit de ces nouvelles technologies, il sera avantageux de construire des reseaux quantiques. Dans un tel reseau, des processeurs quantiques, les noeuds, seront connectes par des photons voyageant dans des fibres optiques. Les reseaux quantiques permettront de deployer les communications quantiques a grande echelle et de creer des super-ordinateurs quantiques. La realisation de reseaux quantiques necessitera des interfaces optiques pouvant echanger l'information de facon coherente entre un qubit (bit d'information quantique) et un photon. L'implementation de telles interfaces dans un systeme physique s'avere un important defi scientifique et technologique. Or, les systemes actuellement envisages a cette fin souffrent d'un faible couplage avec la lumiere ou encore de grandes inhomogeneites, constituant des obstacles a la realisation de reseaux a grande echelle. Dans cette these, le potentiel des centres isoelectroniques pour realiser des interfaces optiques est evalue. Deux types de qubits lies a des paires d'azote dans le GaAs sont consideres : les qubits excitoniques et les qubits de spin electronique, controlables par l'intermediaire d'excitons charges. Le controle optique complet des qubits excitoniques est demontre, ce qui constitue la premiere realisation du genre dans les centres isoelectroniques. L'observation d'excitons charges dans ce systeme, liant a la fois des trous lourds et des trous legers, laisse entrevoir de nouvelles possibilites afin de

  4. The applicability of a material-treatment laser pulse in non-destructive evaluations.

    PubMed

    Hrovatin, R; Petkovsek, R; Diaci, J; Mozina, J

    2006-12-22

    A practical optodynamic study was performed to determine the usability of different lengths of laser pulses for the generation of ultrasonic transients in a solid material. The aim of the study was to evaluate the possibility of a dual use for a laser pulse-for laser material processing, on the one hand, and for the ultrasonic wave generation on the other-with both processes being combined on the same production line. The propagation of the laser-generated ultrasonic waves is evaluated by detecting and measuring with a PID-controlled stabilized interferometer. Thus, both systems provided the basic tools, the generation and detection of ultrasonic waves, for an ultrasonic, laser-based, non-destructive material evaluation. The ultrasonic transients generated by 'classical' nanosecond laser pulses were compared with the transients generated by industrial laser pulses with a duration of a few tenths of a microsecond. The experimental results are compared with the results of a time-of-flight analysis that also involved part of a mode-conversion analysis for both regimes in a layered material structure. The differences between the two waveforms were assessed in terms of their visibility, wavelength and resolution. The limit values were calculated and estimated for the laser-pulse parameters, when such pulses are intended for use in an ultrasonic, laser-based, non-destructive evaluation. The possibility of using an industrial marking laser for laser ultrasound generation is thus demonstrated.

  5. Evaluation of Low-Level Laser Therapy in TMD Patients

    PubMed Central

    Emir, Faruk; Sahin, Cem

    2015-01-01

    Light amplification by stimulated emission of radiation (laser) is one of the most recent treatment modalities in dentistry. Low-level laser therapy (LLLT) is suggested to have biostimulating and analgesic effects through direct irradiation without causing thermal response. There are few studies that have investigated the efficacy of laser therapy in temporomandibular disorders (TMD), especially in reduced mouth opening. The case report here evaluates performance of LLLT with a diode laser for temporomandibular clicking and postoperative findings were evaluated in two cases of TMD patients. First patient had a history of limited mouth opening and pain in temporomandibular joint (TMJ) region since nine months. Second patient's main complaint was his restricted mouth opening, which was progressed in one year. LLLT was performed with a 685 nm red probed diode laser that has an energy density of 6.2 J/cm2, three times a week for one month, and application time was 30 seconds (685 nm, 25 mW, 30 s, 0.02 Hz, and 6.2 J/cm2) (BTL-2000, Portative Laser Therapy Device). The treatment protocol was decided according to the literature. One year later patients were evaluated and there were no changes. This application suggested that LLLT is an appropriate treatment for TMD related pain and limited mouth opening and should be considered as an alternative to other methods. PMID:26587294

  6. Evaluation method based on the image correlation for laser jamming image

    NASA Astrophysics Data System (ADS)

    Che, Jinxi; Li, Zhongmin; Gao, Bo

    2013-09-01

    The jamming effectiveness evaluation of infrared imaging system is an important part of electro-optical countermeasure. The infrared imaging devices in the military are widely used in the searching, tracking and guidance and so many other fields. At the same time, with the continuous development of laser technology, research of laser interference and damage effect developed continuously, laser has been used to disturbing the infrared imaging device. Therefore, the effect evaluation of the infrared imaging system by laser has become a meaningful problem to be solved. The information that the infrared imaging system ultimately present to the user is an image, so the evaluation on jamming effect can be made from the point of assessment of image quality. The image contains two aspects of the information, the light amplitude and light phase, so the image correlation can accurately perform the difference between the original image and disturbed image. In the paper, the evaluation method of digital image correlation, the assessment method of image quality based on Fourier transform, the estimate method of image quality based on error statistic and the evaluation method of based on peak signal noise ratio are analysed. In addition, the advantages and disadvantages of these methods are analysed. Moreover, the infrared disturbing images of the experiment result, in which the thermal infrared imager was interfered by laser, were analysed by using these methods. The results show that the methods can better reflect the jamming effects of the infrared imaging system by laser. Furthermore, there is good consistence between evaluation results by using the methods and the results of subjective visual evaluation. And it also provides well repeatability and convenient quantitative analysis. The feasibility of the methods to evaluate the jamming effect was proved. It has some extent reference value for the studying and developing on electro-optical countermeasures equipments and

  7. Lasers à électrons libres de courtes longueurs d'onde: état de l'art et perspectives

    NASA Astrophysics Data System (ADS)

    Couprie, M. E.

    2003-06-01

    Les Lasers à Électrons Libres (LEL) sont des sources de rayonnement cohérent et accordable, basées sur l'interaction d'un faisceau d'électrons relativistes circulant dans le champ magnétique magnétique périodique et permanent créé par un “onduleur”. et d'une onde optique. L'onde lumineuse peut être issue de l'émission de rayonnement synchroton émise par le paquet d'électrons a chaque passage pour un système super-radiant en mode SASE (Self Amplified Spontaneous Emission- Emission Spontanée Auto-Amplifiée) ou issue du rayonnement synchrotron stocké dans une cavité optique, en mode oscillateur, ou d'une onde laser externe, en mode génération d'harmonique. Sous certaines conditions, l'onde lumineuse est amplifiée, au détriment de l'énergie cinétique des électrons, ce qui conduit à l'effet laser. L'état de l'art des sources Laser à Electrons Libres dans l'UV et le VUV est présenté, en indiquant les complémentarités résultant des différentes configurations tant du point de vue des sources que de leurs utilisations. Les projets de sources de courte longueur d'onde proposés sont ensuite discutés.

  8. Evaluation of intrauterine adhesion treatment by laser hysteroscopy

    NASA Astrophysics Data System (ADS)

    Mutrynowski, Andrzej; Zabielska, Renata

    1996-03-01

    Hysteroscopy, which is a kind of endoscopy, makes it possible to evaluate macroscopically the cervical canal, uterine cavity, and the uterine opening of the oviducts. Laser hysteroscopy is used for removing septa and intrauterine adhesions, polyps, small submucosus myomas, and for endometrium ablation in abnormal metrorrhagias. The paper aims at the initial evaluation of laser hysteroscopy in removing intrauterine adhesions in the cases of 41 infertile women. Among all infertile patients 16 women (39%) conceived. Among others 1 woman (2.5%) did not want to conceive and 19 had other causes of infertility. Thirteen (93%) out of 14 patients with hypomenorrhea before surgery reported improvement of the menstruation cycle after the treatment. Five patients (12%) had adhesions for the second time. The patients had the second laser hysteroscopy. The control diagnostic hysteroscopy showed no adhesions in those cases.

  9. Evaluation des prescriptions antibiotiques au service des urgences de l’Hôpital Militaire d’Instruction Mohammed V (HMIMV)

    PubMed Central

    Elbouti, Anass; Rafai, Mostafa; Chouaib, Naoufal; Jidane, Said; Belkouch, Ahmed; Bakkali, Hicham; Belyamani, Lahcen

    2016-01-01

    Cette étude à pour objectifs de décrire les pratiques des prescriptions, évaluer leur pertinence et leur conformité aux règles d’utilisations et étudier les facteurs susceptibles de les influencer. Il s’agit d’une étude transversale d’évaluation des prescriptions antibiotiques portant sur 105 patients réalisée au service des urgences médico-chirurgicales de l’H.M.I.Med V de Rabat sur une période d’un mois. Le recueil des données était fait à l’aide d’un questionnaire rapportant les données démographiques et anamnestiques, les antécédents, la notion d’allergie, les données spécifiques de l’examen clinique, les données para cliniques, la prescription détaillée de l’antibiotique. Les données récoltées ont été ensuite évaluées par un médecin référent, chargé d’indiquer les éventuelles erreurs de traitement. Parmi les infections ayant motivé la prescription des antibiotiques, les affections des systèmes respiratoires et urinaires étaient au premier rang, les familles d’antibiotiques les plus couramment employées sont les pénicillines, les quinolones et les céphalosporines. 74 prescriptions soit (70,5%) étaient à la fois pertinentes et conformes contre 9 prescriptions soit (8,6%) justifiées mais non pertinentes et 6 prescriptions soit (5,7%) étaient jugées injustifiées par le médecin référent par absence d’infection. Les évaluations des pratiques médicales sont rarement menées dans les établissements de santé; c’est dans ce cadre que nous avons voulu nous inscrire en produisant cette étude afin d’améliorer la pertinence de nos prescriptions antibiotiques et d’optimiser leur conformité aux différentes recommandations. PMID:28292124

  10. Caracterisation des melanges developpes pour le moulage basse pression des poudres metalliques (LPIM) =

    NASA Astrophysics Data System (ADS)

    Fareh, Fouad

    Le moulage par injection basse pression des poudres metalliques est une technique de fabrication qui permet de fabriquer des pieces possedant la complexite des pieces coulees mais avec les proprietes mecaniques des pieces corroyees. Cependant, l'optimisation des etapes de deliantage et de frittage a ete jusqu'a maintenant effectuee a l'aide de melange pour lesquels la moulabilite optimale n'a pas encore ete demontree. Ainsi, la comprehension des proprietes rheologiques et de la segregation des melanges est tres limitee et cela presente le point faible du processus de LPIM. L'objectif de ce projet de recherche etait de caracteriser l'influence des liants sur le comportement rheologique des melanges en mesurant la viscosite et la segregation des melanges faible viscosite utilises dans le procede LPIM. Afin d'atteindre cet objectif, des essais rheologiques et thermogravimetriques ont ete conduits sur 12 melanges. Ces melanges ont ete prepares a base de poudre d'Inconel 718 de forme spherique (chargement solide constant a 60%) et de cires, d'agents surfactants ou epaississants. Les essais rheologiques ont ete utilises entre autre pour calculer l'indice d'injectabilite ?STV des melanges, tandis que les essais thermogravimetriques ont permis d'evaluer precisement la segregation des poudres dans les melanges. Il a ete demontre que les trois (3) melanges contenant de la cire de paraffine et de l'acide stearique presentent des indices alpha STV plus eleves qui sont avantageux pour le moulage par injection des poudres metalliques (MIM), mais segregent beaucoup trop pour que la piece fabriquee produise de bonnes caracteristiques mecaniques. A l'oppose, le melange contenant de la cire de paraffine et de l'ethylene-vinyle acetate ainsi que le melange contenant seulement de la cire de carnauba segregent peu voire pas du tout, mais possedent de tres faibles indices alphaSTV : ils sont donc difficilement injectables. Le meilleur compromis semble donc etre les melanges contenant de

  11. Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators

    DTIC Science & Technology

    2017-07-07

    AFRL-RH-FS-TR-2017-0026 Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators Thomas K. Kuyk Peter A. Smith Solangia...34Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators" (AFRL-RH-FS-TR- 2017 - 0026 SHORTER.PATRI CK.D.1023156390 Digitally...SUBTITLE Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators 5a. CONTRACT NUMBER FA8650-14-D-6519 5b. GRANT NUMBER 5c

  12. Laser range pole field evaluation report

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A field evaluation was made of the laser pole equipment. The basic plan for the evaluation was to expose the equipment to the actual people and environment for which it was intended and determine, through the use of the equipment, its resultant effectivity in terms of improved performance. Results show the equipment performed better than expected in the high elevation clean air of Colorado, and did as well in Tennessee.

  13. Ablation laser pour la microélectronique plastique

    NASA Astrophysics Data System (ADS)

    Alloncle, A.-P.; Thomas, B.; Grojo, D.; Delaporte, Ph.; Sentis, M.; Sanaur, S.; Barret, M.; Collot, Ph.

    2006-12-01

    La microélectronique plastique connaît un développement sans précédent dans le domaine de la recherche. Cette étude s'intéresse à l'utilisation des lasers impulsionnels pour la réalisation de composants organiques sur supports souples. Les deux aspects plus particulièrement étudiés sont d'une part la gravure de polymère pour réaliser un canal entre la source et le drain, et d'autre part le développement d'un procédéde dépôt appelé LIFT pour Laser Induced Forward Transfer. Ce dernier pourrait notamment permettre dedéposer des composés organiques non solubles.

  14. Du pompage optique laser à l'absorption saturée résolue en temps

    NASA Astrophysics Data System (ADS)

    Dumont, M.

    The first part is a brief historical account of the beginning of lasers at the « Laboratoire de Spectroscopie Hertzienne de l'ENS » and, more precisely, of the first experiments of optical pumping with multimode lasers. The three new features (stimulated emission, coherence and saturation) are emphasized. Paragraphes 2 and 3 outline the special behaviour of monomode optical pumping (velocity selection) and of timeresolved saturated absorption. This last technique is applied to study elastic collisions (determination of the « collision Kernel ») and Raman coherence between metastable levels. The last paragraphe summarizes a semi-perturbative calculation of transients in Velocity Selective Optical Pumping (VSOP). La première partie est un survol historique de l'introduction des lasers au laboratoire de Spectroscopie Hertzienne de l'ENS et particulièrement des premières expériences de pompage optique avec un laser multimode. Les trois caractéristiques nouvelles (émission stimulée, cohérence de la lumière et saturations) sont mises en lumière. Les paragraphes 2 et 3 présentent les particularités du pompage optique par un laser monomode (sélection des vitesses atomiques) et de la technique d'absorption saturée résolue en temps. Cette dernière technique est appliquée à l'étude des collisions élastiques (détermination du « noyau de collision ») et de la cohérence Raman entre niveaux métastables. La dernière partie présente, de façon résumée, un calcul semiperturbatif des transitoires de pompage optique sélectif en vitesse (VSOP).

  15. Décontamination nucléaire par laser UV

    NASA Astrophysics Data System (ADS)

    Delaporte, Ph.; Gastaud, M.; Marine, W.; Sentis, M.; Uteza, O.; Thouvenot, P.; Alcaraz, J. L.; Le Samedy, J. M.; Blin, D.

    2003-06-01

    Le développement et l'utilisation de procédés propres pour le nettoyage ou la préparation de surfaces est l'une des priorités du milieu industriel. Cet intérêt est d'autant plus grand dans le domaine du nucléaire pour lequel la réduction des déchets est un axe de recherche important. Un dispositif de décontamination nucléaire par laser UV impulsionnel a été développé et testé. Il est composé. d'un laser à excimères de 1kW, d'un faisceau de fibres optiques et d'un dispositif de récupération des particules. Les essais réalisés en milieu actif ont démontré sa capacité à nettoyer des surfaces métalliques polluées par différents radioéléments avec des facteurs de décontamination généralement supérieurs à 10. Ce dispositif permet de décontaminer de grandes surfaces de géométrie simple en réduisant fortement la génération de déchets secondaires. Il est, à ce jour et dans ces conditions d'utilisations, le procédé de décontamination par voie sèche le plus efficace.

  16. Ingenierie de nanoparticules plasmoniques robustes pour la generation de bulles par laser en vue d'applications biomedicales

    NASA Astrophysics Data System (ADS)

    Lachaine, Remi

    Les chirurgiens generent des bulles dans le corps humain a l'aide d'irradiation laser depuis plusieurs decennies. Ils utilisent ces bulles comme de petits scalpels, leur permettant de faire des incisions precises et localisees. Une des applications de cet outil chirurgical est la perforation cellulaire. Au lieu d'utiliser une aiguille pour perforer la membrane des cellules, il est possible de focaliser des impulsions laser en surface d'une cellule, formant un plasma au point focal du laser et generant une bulle qui perfore la membrane cellulaire. Toutefois, ce procede est assez lent et la perforation massive de cellules in-vivo n'est pas envisageable. Pour accelerer le processus, il est possible d'utiliser des nanoparticules plasmoniques. Ces dernieres agissent comme des nano-antennes qui permettent de concentrer la lumiere sur une echelle nanometrique. La possibilite d'irradier un grand nombre de nanoparticules simultanement a donne un nouvel elan a la generation de bulle comme outil de perforation cellulaire. L'utilisation de nanoparticules dans un contexte biomedical comporte toutefois certains risques. En particulier, la fragmentation de nanoparticules peut augmenter la toxicite du traitement. Dans un cas ideal, il est preferable d'utiliser des nanoparticules qui ne sont pas endommagees par l'irradiation laser. Cette these a pour but de developper une methode d'ingenierie de nanoparticules robustes permettant la generation efficace de bulles a des fins biomedicales. Il est tout d'abord demontre experimentalement que la formation de plasma est bel et bien le mecanisme physique principal menant a la generation de bulles lors de l'irradiation infrarouge (longueur d'onde de 800 nm) et ultrarapide (temps d'impulsion entre 45 fs et 1 ps) de nanoparticules d'or de 100 nm. Pour realiser cette demonstration, une methode pompe-sonde de detection de bulles d'environ 1 mum a ete elaboree. Cette methode a permis de mettre en evidence une difference de taille de 18% entre

  17. Histologic evaluation of laser lipolysis comparing continuous wave vs pulsed lasers in an in vivo pig model.

    PubMed

    Levi, Jessica R; Veerappan, Anna; Chen, Bo; Mirkov, Mirko; Sierra, Ray; Spiegel, Jeffrey H

    2011-01-01

    To evaluate acute and delayed laser effects of subdermal lipolysis and collagen deposition using an in vivo pig model and to compare histologic findings in fatty tissue after continuous wave diode (CW) vs pulsed laser treatment. Three CW lasers (980, 1370, and 1470 nm) and 3 pulsed lasers (1064, 1320, and 1440 nm) were used to treat 4 Göttingen minipigs. Following administration of Klein tumescent solution, a laser cannula was inserted at the top of a 10 × 2.5-cm rectangle and was passed subdermally to create separate laser "tunnels." Temperatures at the surface and at intervals of 4-mm to 20-mm depths were recorded immediately after exposure and were correlated with skin injury. Full-thickness cutaneous biopsy specimens were obtained at 1 day, 1 week, and 1 month after exposure and were stained with hematoxylin-eosin and trichrome stain. Qualitative and semiquantitative histopathologic evaluations were performed with attention to vascular damage, lipolysis, and collagen deposition. Skin surface damage occurred at temperatures exceeding 46°C. Histologic examination at 1 day after exposure showed hemorrhage, fibrous collagen fiber coagulation, and adipocyte damage. Adipocytes surrounded by histiocytes, a marker of lipolysis, were present at 1 week and 1 month after exposure. Collagen deposition in subdermal fatty tissue and in reticular dermis of some specimens was noted at 1 week and had increased at 1 month. Tissue treated with CW laser at 1470 nm demonstrated greater hemorrhage and more histiocytes at damage sites than tissue treated with pulsed laser at 1440 nm. There was a trend toward more collagen deposition with pulsed lasers than with CW lasers, but this was not statistically significant. Histopathologic comparison between results of CW laser at 980 nm vs pulsed laser at 1064 nm showed the same trend. Hemorrhage differences may result from pulse duration variations. A theoretical calculation estimating temperature rise in vessels supported this

  18. Laser/Optical Data Base Products: Evaluation and Selection.

    ERIC Educational Resources Information Center

    Nicholls, Paul Travis

    1988-01-01

    The practical advice for the evaluation of laser/optical data disk materials (e.g., CD-ROM) is based on a review of the relevant literature. An evaluation framework is outlined and collection development tools and sources of published reviews are identified. (34 references) (Author/CLB)

  19. Optimisation thermique de moules d'injection construits par des processus génératifs

    NASA Astrophysics Data System (ADS)

    Boillat, E.; Glardon, R.; Paraschivescu, D.

    2002-12-01

    Une des potentialités les plus remarquables des procédés de production génératifs, comme le frittage sélectif par laser, est leur capacité à fabriquer des moules pour l'injection plastique équipés directement de canaux de refroidissement conformes, parfaitement adaptés aux empreintes Pour que l'industrie de l'injection puisse tirer pleinement parti de cette nouvelle opportunité, il est nécessaire de mettre à la disposition des moulistes des logiciels de simulation capables d'évaluer les gains de productivité et de qualité réalisables avec des systèmes de refroidissement mieux adaptés. Ces logiciels devraient aussi être capables, le cas échéant, de concevoir le système de refroidissement optimal dans des situations où l'empreinte d'injection est complexe. Devant le manque d'outils disponibles dans ce domaine, le but de cet article est de proposer un modèle simple de moules d'injection. Ce modèle permet de comparer différentes stratégies de refroidissement et peut être couplé avec un algorithme d'optimisation.

  20. Evaluating the effects of a 532-nm fiber-based KTP laser on transoral laser surgery supplies.

    PubMed

    Coughlan, Carolyn A; Verma, Sunil P

    2013-11-01

    The KTP laser has become commonplace in transoral head and neck surgery. The interactions of this laser with commonly used supplies in transoral surgery have not been formally examined. This study evaluates the effects of the KTP laser on surgical supplies. Experimental study. The study was conducted in an empty operating room at a university-affiliated medical center. An Aura XP 532-nm KTP laser with a 600-nm fiber was used in pulsed and continuous modes. The beam was focused at the shaft and balloon of 3 "laser-safe" endotracheal tubes (ETTs), a polyvinyl chloride (PVC) ETT, and a Codman surgical patty. Time to penetrate was recorded. Results The KTP laser beam was unable to penetrate any of the laser-resistant ETTs. It did react with the black number markings on the PVC ETT by producing sparks but was unable to penetrate the shaft of the ETT. The KTP laser was nonreactive with all ETT cuffs except in 1 of 3 trials with the outer balloon cuff of a Rusch Lasertubus ETT when the laser was used in a continuous mode. The KTP laser caused the production of a flame upon contact with the blue radiopaque strip of the surgical patty, even when the patty was wet. This study demonstrates that a number of safe ETT options may be used during transoral laser microsurgery with a KTP laser. In addition, Codman surgical patties are shown to be a significant fire risk in KTP laser surgery.

  1. Evaluation des Connaissances-Attitudes-Pratiques des populations des districts sanitaires de Benoye, Laoukassy, Moundou et N’Djaména Sud sur la rage canine au Tchad

    PubMed Central

    Mindekem, Rolande; Lechenne, Monique; Alfaroukh, Idriss Oumar; Moto, Daugla Doumagoum; Zinsstag, Jakob; Ouedraogo, Laurent Tinoaga; Salifou, Sahidou

    2017-01-01

    Introduction La rage canine demeure une préoccupation en Afrique comme au Tchad. La présente étude vise à évaluer les Connaissances-Attitudes-Pratiques des populations pour la prise en charge appropriée des personnes exposées et une lutte efficace. Méthodes C’était une étude transversale descriptive réalisée en juillet et septembre dans quatre districts sanitaires au Tchad en 2015. Les données ont été collectées à l’aide d’un questionnaire auprès des ménages recrutés suivant un sondage aléatoire à 3 degrés. Résultats C’était 2428 personnes enquêtées avec un niveau maximum primaire (54,12%). L’âge moyen était de 36 ± 13,50 ans. Ils étaient cultivateurs (35,17%), commerçants (18,04%), ménagères (12,81%). La rage était définie comme une maladie transmise du chien à l’homme (41,43%), une altération du cerveau (41,27%), une sous-alimentation (10,26%). Le chat était faiblement connu réservoir (13,84%) et vecteur (19,77%) ainsi que la griffure comme moyen de transmission (4,61%) et la vaccination du chat comme mesure préventive (0,49%). Les premiers soins en cas de morsure à domicile étaient les pratiques traditionnelles (47,69%), le lavage des plaies (19,48%) ou aucune action entreprise (20,43%). Les ménages consultaient la santé humaine (78,50%), la santé animale (5,35%) et les guérisseurs traditionnels (27%). Conclusion La communication en rapport avec des premiers soins à la maison en cas de morsure, la connaissance du chat comme réservoir et vecteur, celle de la griffure comme moyen de transmission et la promotion de la consultation des services vétérinaires en cas de morsure sont nécessaires. PMID:28761600

  2. Laser etching of austenitic stainless steels for micro-structural evaluation

    NASA Astrophysics Data System (ADS)

    Baghra, Chetan; Kumar, Aniruddha; Sathe, D. B.; Bhatt, R. B.; Behere, P. G.; Afzal, Mohd

    2015-06-01

    Etching is a key step in metallography to reveal microstructure of polished specimen under an optical microscope. A conventional technique for producing micro-structural contrast is chemical etching. As an alternate, laser etching is investigated since it does not involve use of corrosive reagents and it can be carried out without any physical contact with sample. Laser induced etching technique will be beneficial especially in nuclear industry where materials, being radioactive in nature, are handled inside a glove box. In this paper, experimental results of pulsed Nd-YAG laser based etching of few austenitic stainless steels such as SS 304, SS 316 LN and SS alloy D9 which are chosen as structural material for fabrication of various components of upcoming Prototype Fast Breeder Reactor (PFBR) at Kalpakkam India were reported. Laser etching was done by irradiating samples using nanosecond pulsed Nd-YAG laser beam which was transported into glass paneled glove box using optics. Experiments were carried out to understand effect of laser beam parameters such as wavelength, fluence, pulse repetition rate and number of exposures required for etching of austenitic stainless steel samples. Laser etching of PFBR fuel tube and plug welded joint was also carried to evaluate base metal grain size, depth of fusion at welded joint and heat affected zone in the base metal. Experimental results demonstrated that pulsed Nd-YAG laser etching is a fast and effortless technique which can be effectively employed for non-contact remote etching of austenitic stainless steels for micro-structural evaluation.

  3. Protection performance evaluation regarding imaging sensors hardened against laser dazzling

    NASA Astrophysics Data System (ADS)

    Ritt, Gunnar; Koerber, Michael; Forster, Daniel; Eberle, Bernd

    2015-05-01

    Electro-optical imaging sensors are widely distributed and used for many different purposes, including civil security and military operations. However, laser irradiation can easily disturb their operational capability. Thus, an adequate protection mechanism for electro-optical sensors against dazzling and damaging is highly desirable. Different protection technologies exist now, but none of them satisfies the operational requirements without any constraints. In order to evaluate the performance of various laser protection measures, we present two different approaches based on triangle orientation discrimination on the one hand and structural similarity on the other hand. For both approaches, image analysis algorithms are applied to images taken of a standard test scene with triangular test patterns which is superimposed by dazzling laser light of various irradiance levels. The evaluation methods are applied to three different sensors: a standard complementary metal oxide semiconductor camera, a high dynamic range camera with a nonlinear response curve, and a sensor hardened against laser dazzling.

  4. Les effets des interfaces sur les proprietes magnetiques et de transport des multicouches nickel/iron et cobalt/silver

    NASA Astrophysics Data System (ADS)

    Veres, Teodor

    Cette these est consacree a l'etude de l'evolution structurale des proprietes magnetiques et de transport des multicouches Ni/Fe et nanostructures a base de Co et de l'Ag. Dans une premiere partie, essentiellement bibliographique, nous introduisons quelques concepts de base relies aux proprietes magnetiques et de transport des multicouches metalliques. Ensuite, nous presentons une breve description des methodes d'analyse des resultats. La deuxieme partie est consacree a l'etude des proprietes magnetiques et de transport des multicouches ferromagnetiques/ferromagnetiques Ni/Fe. Nous montrerons qu'une interpretation coherente de ces proprietes necessite la prise en consideration des effets des interfaces. Nous nous attacherons a mettre en evidence, a evaluer et a etudier les effets de ces interfaces ainsi que leur evolution, et ce, suite a des traitements thermiques tel que le depot a temperature elevee et l'irradiation ionique. Les analyses correlees de la structure et de la magnetoresistance nous permettront d'emettre des conclusions sur l'influence des couches tampons entre l'interface et le substrat ainsi qu'entre les couches elles-memes sur le comportement magnetique des couches F/F. La troisieme partie est consacree aux systemes a Magneto-Resistance Geante (MRG) a base de Co et Ag. Nous allons etudier l'evolution de la microstructure suite a l'irradiation avec des ions Si+ ayant une energie de 1 MeV, ainsi que les effets de ces changements sur le comportement magnetique. Cette partie debutera par l'analyse des proprietes d'une multicouche hybride, intermediaire entre les multicouches et les materiaux granulaires. Nous analyserons a l'aide des mesures de diffraction, de relaxation superparamagnetique et de magnetoresistance, les evolutions structurales produites par l'irradiation ionique. Nous etablirons des modeles qui nous aideront a interpreter les resultats pour une serie des multicouches qui couvrent un large eventail de differents comportements magnetiques

  5. Developpement et application d'un systeme mobile de laser terrestre pour quantifier le bilan sedimentaire des plages

    NASA Astrophysics Data System (ADS)

    Van-Wierts, Stefanie

    Au Québec maritime, l'érosion côtière est une problématique d'envergure, notamment sur les côtes de formations meubles. Les plages ont un rôle de zone tampon ayant comme fonction naturelle d'absorber l'énergie des vagues et donc d'assurer l'équilibre de certains écosystèmes et le maintien de l'écoumène en réduisant l'érosion de la côte. Les méthodes d'acquisition conventionnelles ne permettent pas de quantifier convenablement les changements morphosédimentaires d'une plage à l'échelle des cellules hydrosédimentaires. Le manque de méthode d'acquisition fiable et de données quantitatives mène à une surestimation ou à une sous-estimation de la disponibilité sédimentaire d'un système côtier. Pour contrer ces lacunes et afin de minimiser les coûts d'acquisition, un nouveau système mobile de LiDAR terrestre a été mis en place, permettant d'acquérir des données topographiques de l'estran, de la haute plage et des falaises. Le système multicapteurs comprend un LiDAR, un système de navigation à haute précision (IMU et D-GPS) et une caméra. L'ensemble des instruments et capteurs sont montés sur un véhicule de type tout-terrain. Le système a été évalué sur la zone côtière de la péninsule de Manicouagan. La comparaison des données LiDAR avec 1 050 points de référence géopositionnés au D-GPS montre une erreur verticale moyenne de 0,1 m sur les secteurs de plage. Les résultats montrent que le volume sédimentaire moyen des plages devant les zones où la ligne de rivage présente un ouvrage de protection en enrochement (12 m 3/m) est plus de trois fois plus faible que devant les secteurs à l'état naturel (35,5 m3/m). La moyenne des secteurs en transition, constituant les segments où une zone artificielle et une zone naturelle se chevauchent présentent un volume moyen de 28 m3/m. Aussi, les plages devant les secteurs anthropisés sont en moyenne près de 2 fois plus étroites (12,7 m) que devant les secteurs naturels (25

  6. Effect of laser peripheral iridotomy using argon and neodymium-YAG lasers on corneal endothelial cell density: 7-year longitudinal evaluation.

    PubMed

    Ono, Takashi; Iida, Masaharu; Sakisaka, Toshihiro; Minami, Keiichiro; Miyata, Kazunori

    2018-03-01

    To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers. Retrospective case series. Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated. Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy. Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.

  7. The Rapid Disaster Evaluation System (RaDES): A Plan to Improve Global Disaster Response by Privatizing the Assessment Component.

    PubMed

    Iserson, Kenneth V

    2017-09-01

    Emergency medicine personnel frequently respond to major disasters. They expect to have an effective and efficient management system to elegantly allocate available resources. Despite claims to the contrary, experience demonstrates this rarely occurs. This article describes privatizing disaster assessment using a single-purposed, accountable, and well-trained organization. The goal is to achieve elegant disaster assessment, rather than repeatedly exhorting existing groups to do it. The Rapid Disaster Evaluation System (RaDES) would quickly and efficiently assess a postdisaster population's needs. It would use an accountable nongovernmental agency's teams with maximal training, mobility, and flexibility. Designed to augment the Inter-Agency Standing Committee's 2015 Emergency Response Preparedness Plan, RaDES would provide the initial information needed to avoid haphazard and overlapping disaster responses. Rapidly deployed teams would gather information from multiple sources and continually communicate those findings to their base, which would then disseminate them to disaster coordinators in a concise, coherent, and transparent way. The RaDES concept represents an elegant, minimally bureaucratic, and effective rapid response to major disasters. However, its implementation faces logistical, funding, and political obstacles. Developing and maintaining RaDES would require significant funding and political commitment to coordinate the numerous agencies that claim to be performing the same tasks. Although simulations can demonstrate efficacy and deficiencies, only field tests will demonstrate RaDES' power to improve interagency coordination and decrease the cost of major disaster response. At the least, the RaDES concept should serve as a model for discussing how to practicably improve our current chaotic disaster responses. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Acousto-ultrasonic nondestructive evaluation of materials using laser beam generation and detection

    NASA Technical Reports Server (NTRS)

    Huber, Robert D.; Green, Robert E., Jr.; Vary, Alex; Kautz, Harold

    1990-01-01

    Presented in viewgraph format, the possibility of using laser generation and detection of ultrasound to replace piezoelectric transducers for the acousto-ultrasonic technique is advanced. The advantages and disadvantages of laser acousto-ultrasonics are outlined. Laser acousto-ultrasonics complements standard piezoelectric acousto-ultrasonics and offers non-contact nondestructive evaluation.

  9. Instrumentation optique pour l'identification per-operatoire des tissus durant les chirurgies de la thyroide

    NASA Astrophysics Data System (ADS)

    De Montigny, Etienne

    Cette these traite du developpement d'instrumentation pour l'imagerie medicale optique. Ces travaux sont centres sur une application particuliere ; faciliter l'identification des tissus durant les chirurgies de la thyroide et de la parathyroide. La thyroide est une glande situee dans le cou, attachee au larynx a la hauteur de la pomme d'Adam. Elle est entouree de plusieurs structures importantes : muscles, nerfs et glandes parathyroides. Ces dernieres controlent la calcemie et jouent donc un role essentiel dans le corps. Elles sont toutefois de petite taille et sont tres difficiles a distinguer du gras et des ganglions environnants. L'objectif principal de cette these est de developper une instrumentation basee sur la microscopie optique pour permettre l'identification des tissus : thyroide, parathyroide, gras et ganglions, durant les chirurgies. Les choix sont donc faits en fonction de cette application et du contexte specifique des mesures intra-operatoires sur des patients humains. Plusieurs modalites d'imagerie optique sont identifiees pour atteindre l'objectif : microscopie confocale en reflectance, tomographique par coherence optique, et mesure de l'autofluorescence des glandes parathyroides. Dans le but d'ameliorer leur compatibilite avec l'environnement clinique qui requiert stabilite dans le temps et resistance aux vibrations et aux conditions environnementales, ce projet se concentre sur les implementations miniaturisables et basees sur des fibres optiques. Pour implementer un systeme d'imagerie en fluorescence a balayage laser rapide, un systeme d'imagerie en fluorescence par encodage spectral est propose. Bien que l'utilisation de l'encodage spectral semble a priori incompatible avec le contraste en fluorescence, une implementation facile a realiser est proposee. Une seconde version du montage, compatible avec la clinique et facilitant le developpement d'un endoscope, est presentee. La preuve de principe de cette methode est faite a 1300nm, une longueur

  10. Le role du phytoplancton de petite taille (<20 mum) dans les variations des proprietes optiques des eaux du Saint-Laurent

    NASA Astrophysics Data System (ADS)

    Mas, Sebastien

    Les mesures satellitaires de couleur des oceans sont largement determinees par les proprietes optiques inherentes (IOPs) des eaux de surface. D'autre part, le phytoplancton de petite taille (<20 mum) est le plus souvent dominant dans les oceans, et peut donc etre une source importante de variation des IOPs dans les oceans. Dans ce contexte, le but principal de ce doctorat etait de definir l'impact du phytoplancton (<20 mum) sur les variations des proprietes optiques de l'Estuaire et du Golfe du Saint-Laurent (Canada). Afin d'atteindre cet objectif, il etait necessaire de determiner en milieu controle les facteurs de variabilite des proprietes optiques cellulaires et des IOPs du phytoplancton (<20 mum) des eaux du Saint-Laurent, et d'evaluer la contribution du phytoplancton (<20 mum) aux proprietes optiques totales des eaux du Saint-Laurent. Des experiences en laboratoire ont montre que les variations des proprietes optiques des cellules phytoplanctoniques soumises a un cycle jour-nuit, ainsi qu'a des changements concomitants d'intensite lumineuse, peuvent contribuer significativement a la variabilite des proprietes optiques observee en milieu naturel. D'autres experiences ont, quant a elles, mis en evidence que les variations des proprietes optiques des cellules phytoplanctoniques dues aux phases de croissance peuvent alterer les IOPs des oceans, particulierement pendant les periodes de floraison. De plus, la presence de bacteries et de particules detritiques peut egalement affecter la variabilite des IOPs totales, notamment la diffusion. Au printemps, dans l'Estuaire et le Golfe du Saint-Laurent, la contribution du phytoplancton <20 mum aux IOPs presentait des differences regionales evidentes pour les proprietes d'absorption et de diffusion. En plus de la variabilite spatiale, les proprietes optiques cellulaires presentaient des variations journalieres, et ce particulierement pour le picophytoplancton. Enfin, la plupart des differences observees dans les

  11. Development and psychometric evaluation of the Decisional Engagement Scale (DES-10): A patient-reported psychosocial survey for quality cancer care.

    PubMed

    Hoerger, Michael; Chapman, Benjamin P; Mohile, Supriya G; Duberstein, Paul R

    2016-09-01

    In light of recent health care reforms, we have provided an illustrative example of new opportunities available for psychologists to develop patient-reported measures related to health care quality. Patient engagement in health care decision making has been increasingly acknowledged as a vital component of quality cancer care. We developed the 10-item Decisional Engagement Scale (DES-10), a patient-reported measure of engagement in decision making in cancer care that assesses patients' awareness of their diagnosis, sense of empowerment and involvement, and level of information seeking and planning. The National Institutes of Health's ResearchMatch recruitment tool was used to facilitate Internet-mediated data collection from 376 patients with cancer. DES-10 scores demonstrated good internal consistency reliability (α = .80), and the hypothesized unidimensional factor structure fit the data well. The reliability and factor structure were supported across subgroups based on demographic, socioeconomic, and health characteristics. Higher DES-10 scores were associated with better health-related quality of life (r = .31). In concurrent validity analyses controlling for age, socioeconomic status, and health-related quality of life, higher DES-10 scores were associated with higher scores on quality-of-care indices, including greater awareness of one's treatments, greater preferences for shared decision making, and clearer preferences about end-of-life care. A mini-measure, the DES-3, also performed well psychometrically. In conclusion, DES-10 and DES-3 scores showed evidence of reliability and validity, and these brief patient-reported measures can be used by researchers, clinicians, nonprofits, hospitals, insurers, and policymakers interested in evaluating and improving the quality of cancer care. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  12. Evaluating the damage process of dynamic target by high-energy laser in ocean environment

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Ye, Demao

    2013-12-01

    The high-energy laser, as one of directed energy weapon, is famous for its unique advantage of speed-of-light response which was considered as an ideal weapon against anti-ship missile. This paper commits to evaluate the damage process of missile by high-energy laser weapon. We analyze the propagation properties which are susceptible to atmospheric attenuation effects, atmospheric turbulence effects, thermal blooming effects in sky-sea atmosphere firstly. Then because laser weapons attack one target at a time and it takes several seconds at a minimum for the target engaged, a model of calculating the required t ime for damaging the attack target was built . In the end effective evaluation methods of hot-ablated and high-energy laser weapon's damaging effectiveness are made, when the body or the optical elements of the missile is irradiated by the concatenation wave laser weapon. And one of the issues just as laser power, propagation distance is changed; the model can make different evaluation. The above model can provide the theoretical basis for the high-energy laser weapon intercept anti-ship missile and tactic deraign rationality for naval ship-borne laser weapons.

  13. Laser biostimulation of articular cartilage: in vitro evaluation

    NASA Astrophysics Data System (ADS)

    Jia, Yali; Guo, Zhouyi; Yang, Xiaohong; Zeng, Chang-Chun

    2004-07-01

    In the orthopaedic field, the repair of ariticular cartilage is still a difficult problem, because of the physiological characters of cartilaginous tissues and chondrocytes. To find an effective method of stimulating their regeneration, this in vitro study focuses on the biostimulation of rabbit articular chondrocytes by low-power He-Ne laser. The articular chondrocytes isolated from the cartilage of the medial condyle of the femur of the rabbit were incubated in HamF12 medium. The second passage culture were spread on 24 petri dishes and were irradiated with laser at power density of 2 - 12 mW/cm2 for 6.5 minutes, corresponding to the energy density of 1-6 J/cm2. Laser treatment was performed three times at a 24-hour interval. After lasering, incubation was continued for 24 hours. Non-irradiated cells were kept under the same conditions as the irradiated ones. The cell proliferation activity was evaluated with a XTT colorimetric method. Irradiation of 4 - 6 J/cm2 revealed a considerably higher cell proliferation activity comparing to control cultures. Thereinto, the energy density of 4 and 5 J/cm2 remarkably increased cell growth (P<0.01). The present study showed that a particular laser irradiation stimulates articular chondrocytes proliferation. These findings might be clinically relevant, indicating that low-power laser irradiation treatment is likely to achieve the repair of articular cartilage in clinic.

  14. Prediction du profil de durete de l'acier AISI 4340 traite thermiquement au laser

    NASA Astrophysics Data System (ADS)

    Maamri, Ilyes

    Les traitements thermiques de surfaces sont des procedes qui visent a conferer au coeur et a la surface des pieces mecaniques des proprietes differentes. Ils permettent d'ameliorer la resistance a l'usure et a la fatigue en durcissant les zones critiques superficielles par des apports thermiques courts et localises. Parmi les procedes qui se distinguent par leur capacite en terme de puissance surfacique, le traitement thermique de surface au laser offre des cycles thermiques rapides, localises et precis tout en limitant les risques de deformations indesirables. Les proprietes mecaniques de la zone durcie obtenue par ce procede dependent des proprietes physicochimiques du materiau a traiter et de plusieurs parametres du procede. Pour etre en mesure d'exploiter adequatement les ressources qu'offre ce procede, il est necessaire de developper des strategies permettant de controler et regler les parametres de maniere a produire avec precision les caracteristiques desirees pour la surface durcie sans recourir au classique long et couteux processus essai-erreur. L'objectif du projet consiste donc a developper des modeles pour predire le profil de durete dans le cas de traitement thermique de pieces en acier AISI 4340. Pour comprendre le comportement du procede et evaluer les effets des differents parametres sur la qualite du traitement, une etude de sensibilite a ete menee en se basant sur une planification experimentale structuree combinee a des techniques d'analyse statistiques eprouvees. Les resultats de cette etude ont permis l'identification des variables les plus pertinentes a exploiter pour la modelisation. Suite a cette analyse et dans le but d'elaborer un premier modele, deux techniques de modelisation ont ete considerees, soient la regression multiple et les reseaux de neurones. Les deux techniques ont conduit a des modeles de qualite acceptable avec une precision d'environ 90%. Pour ameliorer les performances des modeles a base de reseaux de neurones, deux

  15. Application of millisecond pulsed laser for thermal fatigue property evaluation

    NASA Astrophysics Data System (ADS)

    Pan, Sining; Yu, Gang; Li, Shaoxia; He, Xiuli; Xia, Chunyang; Ning, Weijian; Zheng, Caiyun

    2018-02-01

    An approach based on millisecond pulsed laser is proposed for thermal fatigue property evaluation in this paper. Cyclic thermal stresses and strains within millisecond interval are induced by complex and transient temperature gradients with pulsed laser heating. The influence of laser parameters on surface temperature is studied. The combination of low pulse repetition rate and high pulse energy produces small temperature oscillation, while high pulse repetition rate and low pulse energy introduces large temperature shock. The possibility of application is confirmed by two thermal fatigue tests of compacted graphite iron with different laser controlled modes. The developed approach is able to fulfill the preset temperature cycles and simulate thermal fatigue failure of engine components.

  16. Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy

    PubMed Central

    Wróbel, Maciej S.; Jędrzejewska-Szczerska, Malgorzata; Galla, Stanislaw; Piechowski, Leszek; Sawczak, Miroslaw; Popov, Alexey P.; Bykov, Alexander V.; Tuchin, Valery V.; Cenian, Adam

    2015-01-01

    Abstract. Skin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to thermal conductivity and capacitance); thus, they can be used as substitutes for human skin for approximate evaluation of laser heating efficiency in an almost real environment. Thermographic imaging was applied to measure the spatial and temporal temperature distributions on the surface of laser-irradiated phantoms. The study yielded results of heating with regard to phantom thickness and absorption, as well as laser settings. The methodology developed can be used in practice for preclinical evaluations of laser treatment for dermatology. PMID:26263414

  17. Clinical and Spectrophotometric Evaluation of LED and Laser Activated Teeth Bleaching.

    PubMed

    Lo Giudice, R; Pantaleo, G; Lizio, A; Romeo, U; Castiello, G; Spagnuolo, G; Giudice, G Lo

    2016-01-01

    Auxiliary power sources (LED and laser) are used in in-office teeth bleaching techniques to accelerate the redox reaction of the whitening gel to increase ease of use, to improve comfort and safety, and to decrease the procedure time. The aim this study is to evaluate the efficiency of the teeth whitening procedures performed with hydrogen peroxide and carbamide peroxide, LED or Laser activated. 18 patients, affected by exogenous dyschromia, were treated with a bleaching agent composed by 35% hydrogen peroxide and 10% carbamide peroxide. They were divided into two groups: in the first group the bleaching agent was activated by a LED lamp; in the second group it was activated by a Laser diode lamp. Both groups were subjected to 3 bleaching cycle of 15' each. The chromatic evaluations were performed before and after one week from the treatment, using a chromatic scale and a spectrophotometer. The mean value of pre, post bleaching and follow-up were analyzed using a T-test, with results statistically significant for P<0,05. Results showed that the variations in brightness, chroma and hue are significantly influenced by the interaction between the whitening agent and the original colour of the teeth. Laser-activation has marginally improved the bleaching effectiveness. All patients treated with laser activation complained an increase in dental sensitivity. The use of laser-activating systems did not improve the efficacy of bleaching.

  18. Customer Overview of Pulsed Laser Heating for Evaluation of Gun Bore Materials

    DTIC Science & Technology

    2015-05-01

    Technical Report ARWSB-TR-15003 Customer Overview of Pulsed Laser Heating for Evaluation of Gun Bore Materials Mark E. Todaro...SUBTITLE Customer Overview of Pulsed Laser Heating for Evaluation of Gun Bore Materials 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...thermomechanical effects that occur at the bore of large and medium caliber guns during firing. Hence, PLH has been used not only to gain insight into the erosion

  19. Evaluation of Skylab earth laser beacon imagery. [spaceborne photography

    NASA Technical Reports Server (NTRS)

    Piech, K. R.; Schott, J. R.

    1975-01-01

    During the Skylab 3 and 4 missions the Skylab spacecraft was illuminated by a low power argon ion and dye laser. The earth laser beacon was studied visually by the astronauts. In addition, they collected 35 mm hand-held color photographs of the beacons. Photographs are shown that were obtained on Skylab 3 and Skylab 4. The imagery collected during the Skylab mission was analyzed to evaluate the utility of beacon lasers as terrestial 'artificial stars' for space navigation. The analyses of the imagery revealed two unusual features of the earth laser beacon: (1) The beacon, even though of a low power (approximately 1 watt), is considerably brighter than any other terrain feature and is readily visible on imagery at a distance in excess of 1500 km (900 miles). (2) Another feature of the beacon is its large size. The typical beacon extends over about 5 resolution areas with a characteristic dimension of about 200 m.

  20. Diagnostics for the detection and evaluation of laser induced damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, L.; Kozlowski, M.; Rainer, F.

    1995-12-31

    The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less

  1. Diagnostics for the detection and evaluation of laser induced damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, L.; Kozlowski, M.; Rainer, F.

    1995-01-03

    The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less

  2. Vers la diode laser organique ?

    NASA Astrophysics Data System (ADS)

    Horowitz, G.

    1998-06-01

    The recent report of a laser effect in polyparaphenylenevinylene has raised up a great interest. Here, we review the works in that field. Stimulated emission (SE) in conjugated polymers (PCs) manifests itself by a spectral narrowing and a shortening of the emission life time. By putting the emitting medium into microcavity, an increase of the emission directionality has also been reported. We also give results on SE in sexithiophene (6T) single crystals. An analysis of the emitting levels shows that we are dealing with a four level system, which could account for the low excitation threshold. L'annonce récente d'un possible effet laser dans le polyparaphénylè nevinylène (PPV) a suscité un grand intérêt. Nous faisons ici le point sur les travaux dans ce domaine. L'émission stimulée (ES) dans les polymères conjugués (PC) se manifeste par un rétrécissement spectral et un raccourcissement de la durée de vie d'émission. En plaçant le milieu émissif dans une micro-cavité, une augmentation de la directionnalité de l'émission a été observée. Nous donnons par ailleurs des résultats sur l'ES dans des monocristaux de sexithiophène (6T). L'analyse des niveaux émissifs montre qu'il s'agit . d'un système à quatre niveaux, ce qui pourrait expliquer le faible seuil d'excitation.

  3. Residual stress evaluation of components produced via direct metal laser sintering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kemerling, Brandon; Lippold, John C.; Fancher, Christopher M.

    Direct metal laser sintering is an additive manufacturing process which is capable of fabricating three-dimensional components using a laser energy source and metal powder particles. Despite the numerous benefits offered by this technology, the process maturity is low with respect to traditional subtractive manufacturing methods. Relationships between key processing parameters and final part properties are generally lacking and require further development. In this study, residual stresses were evaluated as a function of key process variables. The variables evaluated included laser scan strategy and build plate preheat temperature. Residual stresses were measured experimentally via neutron diffraction and computationally via finite elementmore » analysis. Good agreement was shown between the experimental and computational results. Results showed variations in the residual stress profile as a function of laser scan strategy. Compressive stresses were dominant along the build height (z) direction, and tensile stresses were dominant in the x and y directions. Build plate preheating was shown to be an effective method for alleviating residual stress due to the reduction in thermal gradient.« less

  4. Residual stress evaluation of components produced via direct metal laser sintering

    DOE PAGES

    Kemerling, Brandon; Lippold, John C.; Fancher, Christopher M.; ...

    2018-03-22

    Direct metal laser sintering is an additive manufacturing process which is capable of fabricating three-dimensional components using a laser energy source and metal powder particles. Despite the numerous benefits offered by this technology, the process maturity is low with respect to traditional subtractive manufacturing methods. Relationships between key processing parameters and final part properties are generally lacking and require further development. In this study, residual stresses were evaluated as a function of key process variables. The variables evaluated included laser scan strategy and build plate preheat temperature. Residual stresses were measured experimentally via neutron diffraction and computationally via finite elementmore » analysis. Good agreement was shown between the experimental and computational results. Results showed variations in the residual stress profile as a function of laser scan strategy. Compressive stresses were dominant along the build height (z) direction, and tensile stresses were dominant in the x and y directions. Build plate preheating was shown to be an effective method for alleviating residual stress due to the reduction in thermal gradient.« less

  5. Modification of structural and transport properties in epitaxial YBa2CU3Ox films by pulsed laser irradiation

    NASA Astrophysics Data System (ADS)

    Chechenin, N. G.; Chernysh, A. V.; Korneev, V. V.; Monakhov, E. V.; Seleznev, B. V.

    1993-12-01

    Pulsed (~20 ns) laser effects in epitaxial YBa2CU3Ox/SrTiO3 thin films were investigated, using RBS/channeling for compositional and structural characterization and 4-point technique for electrical measurements. It was found that laser pulse melting and following quenching lead to a transition from a single-crystalline to a polycrystalline state in films. The formation of grain boundaries causes a room temperature electrical resistivity increase by a factor 10-40, depending on the initial film properties and on the irradiation conditions. Unlike corpuscular (ions, neutrons) irradiation, the laser pulse induced structural damage did not lead to the disappearance of HTS, which persisted up to the highest laser fluences used. It was found, that a thermal model can consistently describe the fluence dependence of disorder, depth of surface relief and helps, with a simple two-layer model, in understanding of fluence dependence of room temperature resistivity in a relatively thick film. Les effects de pulses laser (~20 ns) sur des films minces épitaxiés d'YBa2Cu3Ox/SrTiO3 ont été étudiés par rétrodiffusion Rutherford et canalisation afin de caractériser leur composition et leur structure et à l'aide de la technique des 4 points pour les mesures électriques. On a trouvé que la fusion par pulse laser suivie par une trempe entraîne une transition d'un film monocristallin vers un film polycristallin. La formation de joints de grains s'accompagne d'une augmentation d'un facteur 10-40, de la résistivité électrique à température ambiante, dépendante des propriétés initiales du film et des conditions d'irradiation. Contrairement à l'irradiation corpusculaire (ions, neutrons) l'endommagement produit par la pulse laser n'entraîne pas la disparition de la superconductivité à haute température (HTS), qui persiste jusqu'aux plus hautes doses utilisées. On a trouvé qu'un modèle thermique peut décrire de façon consistante, la profondeur de la rugosité de

  6. Histological evaluation of the equine larynx after unilateral laser-assisted ventriculocordectomy.

    PubMed

    Robinson, P; Williams, K J; Sullins, K E; Arnoczky, S P; Stick, J A; Robinson, N E; de Feijter-Rupp, H; Derksen, F J

    2007-05-01

    Trans-endoscopic laser surgery, such as unilateral laser-assisted ventriculocordectomy (LVC), has gained popularity in the treatment of RLN because a laryngotomy incision or general anaesthesia are not required. However, removal of the vocal fold and ventricle takes considerable laser energy and could cause collateral tissue damage, including injury to the adjacent laryngeal cartilages. To document the histological effects of laser surgery on laryngeal tissues in horses that have undergone LVC for the treatment of laryngeal hemiplegia (LH). Six horses were used: 4 with experimentally induced LH that had subsequently undergone LVC 6 months prior to euthanasia; and, 2 horses were used as controls. One of the control horses with naturally occurring LH was used to study the effect of neuropathy alone, whereas the other was subjected to euthanasia immediately following LVC to evaluate the acute effect of laser surgery. Using a band saw, each larynx was sectioned transversely at 5 mm intervals and evaluated histologically. Acutely, LVC caused thermal damage to adjacent soft tissues but did not affect the histology of the laryngeal cartilages. Six months after LVC, laryngeal cartilages were histologically normal and there was squamous metaplasia of the repaired laryngeal mucosa, resulting in restitution of the mucosal integrity. Using a diode laser in contact fashion at 20 W, LVC can be used to remove the laryngeal vocal fold and ventricle without causing laryngeal cartilage damage. Laryngeal chondritis is an unlikely consequence of LVC.

  7. Clinical and Spectrophotometric Evaluation of LED and Laser Activated Teeth Bleaching

    PubMed Central

    Lo Giudice, R.; Pantaleo, G.; Lizio, A.; Romeo, U.; Castiello, G.; Spagnuolo, G.; Giudice, G. Lo

    2016-01-01

    Background: Auxiliary power sources (LED and laser) are used in in-office teeth bleaching techniques to accelerate the redox reaction of the whitening gel to increase ease of use, to improve comfort and safety, and to decrease the procedure time. Objective: The aim this study is to evaluate the efficiency of the teeth whitening procedures performed with hydrogen peroxide and carbamide peroxide, LED or Laser activated. Method: 18 patients, affected by exogenous dyschromia, were treated with a bleaching agent composed by 35% hydrogen peroxide and 10% carbamide peroxide. They were divided into two groups: in the first group the bleaching agent was activated by a LED lamp; in the second group it was activated by a Laser diode lamp. Both groups were subjected to 3 bleaching cycle of 15’ each. The chromatic evaluations were performed before and after one week from the treatment, using a chromatic scale and a spectrophotometer. The mean value of pre, post bleaching and follow-up were analyzed using a T-test, with results statistically significant for P<0,05. Results: Results showed that the variations in brightness, chroma and hue are significantly influenced by the interaction between the whitening agent and the original colour of the teeth. Laser-activation has marginally improved the bleaching effectiveness. All patients treated with laser activation complained an increase in dental sensitivity. Conclusion: The use of laser-activating systems did not improve the efficacy of bleaching. PMID:27386010

  8. Survey of Laser-Produced Pressure and Impulse Data

    DTIC Science & Technology

    1988-01-01

    Marseille, Marseille, France; C.E.A. Limeil-Service H.D.E., St. Georges , France Experimental Conditions: Laser: TEA C02 Wavelength: 10.6 pm Pulse energy: to...Mecanique des Fluides de Marseille, Marseille, France; C.E.A. Limeil-Service H.D.E., St. Georges , France Experimental Conditions: Laser: TEA CO2 Wavelength...34 Authors : C.L. Bohn, M.D. Stephen, F. Eng, J.C. Souders, G.A. Brost , T.F. Deaton, B.W. Duvall, and J.T. Tinsley Citation: "Mechanical coupling of an

  9. Laser ultrasonic evaluation of human dental enamel during remineralization treatment

    PubMed Central

    Wang, Hsiao-Chuan; Fleming, Simon; Lee, Yung-Chun; Swain, Michael; Law, Susan; Xue, Jing

    2011-01-01

    In this work a non-destructive laser ultrasonic technique is used to quantitatively evaluate the progressive change in the elastic response of human dental enamel during a remineralization treatment. The condition of the enamel was measured during two weeks treatment using laser generated and detected surface acoustic waves in sound and demineralized enamel. Analysis of the acoustic velocity dispersion confirms the efficacy, as well as illuminating the progress, of the treatment. PMID:21339879

  10. Evaluation of a new laser-resistant fabric and copper foil-wrapped endotracheal tube.

    PubMed

    Sosis, M B; Braverman, B; Caldarelli, D D

    1996-07-01

    The risk of an endotracheal tube's combustion during laser airway surgery necessitates the use of special anesthetic techniques and equipment to prevent this complication. This study was designed to evaluate the Laser-Trach(TM), a new laser-resistant rubber endotracheal tube for use during laser airway surgery. The Laser-Trach endotracheal tubes that were evaluated were size 6.0 mm internal diameter (ID) red rubber endotracheal tubes which had been commercially wrapped by Kendall-Sheridan (Mansfield, Mass.) with copper foil tape and overwrapped with fabric. The fabric layer was saturated with water prior to our tests, as recommended by the manufacturer. The Laser-Trach endotracheal tubes were compared with plain (bare) size 6.0 mm ID Rusch red rubber endotracheal tubes. The tubes under study were positioned horizontally on wet towels in air and had 5 L x min(-1) of oxygen flowing through them. They were subjected to continuous laser radiation at 40 W from either a CO2 or an Nd-YAG laser. The Nd-YAG laser was propagated via a 600-micron fiber bundle. Each laser was directed perpendicularly at the shaft of the endotracheal tube being studied, and its output was continued until a blowtorch fire occurred or 60 seconds had elapsed. Sixty seconds of CO2 laser fire did not ignite any of the eight Laser-Trach endotracheal tubes tested. However, blowtorch ignition of all eight bare rubber tubes tested occurred after 0.87 +/- 0.21 (mean +/- SD) seconds of CO2 laser fire. Nd-YAG laser contact with the Laser-Trach endotracheal tubes caused the perforation and blowtorch ignition of all eight tubes tested after 18.79 +/- 7.83 seconds. This was a significantly (P<.05) longer time than the 5.45 +/- 4.75 seconds required for the blowtorch ignition of all eight plain rubber endotracheal tubes tested with the Nd-YAG laser. Our results show that under the conditions of this study, the shafts of the Kendall-Sheridan Laser-Trach endotracheal tubes were resistant to the C02 laser

  11. Bibliography of Soviet Laser Developments, No. 16, April - June 1974

    DTIC Science & Technology

    1974-11-01

    Radiofiz Acta physica polonica Bulletin de I’Academic Polonaise del Sciences. Serie des Sciences Terhniqurs Akademiya nauk Armyanskoy SSR. DokUdy...V. Kryukov (0). Spectral kinetics of radiation from complex organic dye solution lasers. Acta phys. et ehem. Szeged, v. 19, no

  12. Thermographic and clinical evaluation of 808-nm laser photobiomodulation effects after third molar extraction.

    PubMed

    Pedreira, Amanda A; Wanderley, Flavia G; Sa, Maira F; Viena, Camila S; Perez, Adriano; Hoshi, Ryuichi; Leite, Marcia P; Reis, Silvia R; Medrado, Alena P

    2016-08-01

    A randomized, blind, controlled clinical study was conducted with a convenience sample of 24 patients to evaluate the effectiveness of an aluminum gallium arsenide (AlGaAs) infrared laser 808 nm after third molar extraction by the use of infrared thermography technique. Patients were divided into four groups: erupted third molars were extracted from the patients in Group I and Group II, and impacted third molars were extracted from the patients in Group III and Group IV. Group I and Group III received mock laser therapy in which the device was powered off, and Group II and Group IV were exposed to laser light. Postoperative clinical parameters related to the third molar extraction were evaluated; these parameters included pain, trismus and edema. Circulatory patterns were also evaluated by infrared thermography that exhibited local temperature coefficient at different postoperative periods. A slight improvement was observed for swelling, pain and trismus in patients who received laser irradiation, although the differences were not statistically significant (P>0.05). Laser therapy had a significant influence on the local circulation in the area near the temporomandibular joint, as determined by infrared thermography (P<0.05). Laser therapy was able to change the local circulation, although it did not significantly influence swelling, pain or trismus during the postoperative period.

  13. Evaluating the beam quality of double-cladding fiber lasers in applications.

    PubMed

    Yan, Ping; Wang, Xuejiao; Gong, Mali; Xiao, Qirong

    2016-08-10

    We put forward a new βFL factor, which is used exclusively in fiber lasers and is suitable to assess beam quality and choose the LP01 mode as the new suitable ideal beam. We present a new simple measurement method and verify the reasonability of the βFL factor in experiment in a 20/400 μm fiber laser. Furthermore, we use the βFL factor to evaluate the beam quality of a 3-kW-level fiber laser. It can be concluded that βFL is a key factor not only for assessing the performance of the high-power fiber laser that is our main focus, but also for the simple measurement.

  14. Randomized Trial Evaluating Ranibizumab Plus Prompt or Deferred Laser or Triamcinolone Plus Prompt Laser for Diabetic Macular Edema

    PubMed Central

    Elman, Michael J.; Aiello, Lloyd Paul; Beck, Roy W.; Bressler, Neil M.; Bressler, Susan B.; Edwards, Allison R.; Ferris, Frederick L.; Friedman, Scott M.; Glassman, Adam R.; Miller, Kellee M.; Scott, Ingrid U.; Stockdale, Cynthia R.; Sun, Jennifer K.

    2010-01-01

    Objective Evaluate intravitreal 0.5 mg ranibizumab or 4 mg triamcinolone combined with focal/grid laser compared with focal/grid laser alone for treatment of diabetic macular edema (DME). Design Multicenter, randomized clinical trial. Participants A total of 854 study eyes of 691 participants with visual acuity (approximate Snellen equivalent) of 20/32 to 20/320 and DME involving the fovea. Methods Eyes were randomized to sham injection + prompt laser (n=293), 0.5 mg ranibizumab + prompt laser (n=187), 0.5 mg ranibizumab + deferred (≥24 weeks) laser (n=188), or 4 mg triamcinolone + prompt laser (n=186). Retreatment followed an algorithm facilitated by a web-based, real-time data-entry system. Main Outcome Measures Best-corrected visual acuity and safety at 1 year. Results The 1-year mean change (±standard deviation) in the visual acuity letter score from baseline was significantly greater in the ranibizumab + prompt laser group (+9±11, P<0.001) and ranibizumab + deferred laser group (+9±12, P<0.001) but not in the triamcinolone + prompt laser group (+4±13, P=0.31) compared with the sham + prompt laser group (+3±13). Reduction in mean central subfield thickness in the triamcinolone + prompt laser group was similar to both ranibizumab groups and greater than in the sham + prompt laser group. In the subset of pseudophakic eyes at baseline (n=273), visual acuity improvement in the triamcinolone + prompt laser group appeared comparable to that in the ranibizumab groups. No systemic events attributable to study treatment were apparent. Three eyes (0.8%) had injection-related endophthalmitis in the ranibizumab groups, whereas elevated intraocular pressure and cataract surgery were more frequent in the triamcinolone + prompt laser group. Two-year visual acuity outcomes were similar to 1-year outcomes. Conclusions Intravitreal ranibizumab with prompt or deferred laser is more effective through at least 1 year compared with prompt laser alone for the treatment of DME

  15. Randomized trial evaluating ranibizumab plus prompt or deferred laser or triamcinolone plus prompt laser for diabetic macular edema.

    PubMed

    Elman, Michael J; Aiello, Lloyd Paul; Beck, Roy W; Bressler, Neil M; Bressler, Susan B; Edwards, Allison R; Ferris, Frederick L; Friedman, Scott M; Glassman, Adam R; Miller, Kellee M; Scott, Ingrid U; Stockdale, Cynthia R; Sun, Jennifer K

    2010-06-01

    Evaluate intravitreal 0.5 mg ranibizumab or 4 mg triamcinolone combined with focal/grid laser compared with focal/grid laser alone for treatment of diabetic macular edema (DME). Multicenter, randomized clinical trial. A total of 854 study eyes of 691 participants with visual acuity (approximate Snellen equivalent) of 20/32 to 20/320 and DME involving the fovea. Eyes were randomized to sham injection + prompt laser (n=293), 0.5 mg ranibizumab + prompt laser (n=187), 0.5 mg ranibizumab + deferred (> or =24 weeks) laser (n=188), or 4 mg triamcinolone + prompt laser (n=186). Retreatment followed an algorithm facilitated by a web-based, real-time data-entry system. Best-corrected visual acuity and safety at 1 year. The 1-year mean change (+/-standard deviation) in the visual acuity letter score from baseline was significantly greater in the ranibizumab + prompt laser group (+9+/-11, P<0.001) and ranibizumab + deferred laser group (+9+/-12, P<0.001) but not in the triamcinolone + prompt laser group (+4+/-13, P=0.31) compared with the sham + prompt laser group (+3+/-13). Reduction in mean central subfield thickness in the triamcinolone + prompt laser group was similar to both ranibizumab groups and greater than in the sham + prompt laser group. In the subset of pseudophakic eyes at baseline (n=273), visual acuity improvement in the triamcinolone + prompt laser group appeared comparable to that in the ranibizumab groups. No systemic events attributable to study treatment were apparent. Three eyes (0.8%) had injection-related endophthalmitis in the ranibizumab groups, whereas elevated intraocular pressure and cataract surgery were more frequent in the triamcinolone + prompt laser group. Two-year visual acuity outcomes were similar to 1-year outcomes. Intravitreal ranibizumab with prompt or deferred laser is more effective through at least 1 year compared with prompt laser alone for the treatment of DME involving the central macula. Ranibizumab as applied in this study

  16. Non-destructive evaluation of UV pulse laser-induced damage performance of fused silica optics.

    PubMed

    Huang, Jin; Wang, Fengrui; Liu, Hongjie; Geng, Feng; Jiang, Xiaodong; Sun, Laixi; Ye, Xin; Li, Qingzhi; Wu, Weidong; Zheng, Wanguo; Sun, Dunlu

    2017-11-24

    The surface laser damage performance of fused silica optics is related to the distribution of surface defects. In this study, we used chemical etching assisted by ultrasound and magnetorheological finishing to modify defect distribution in a fused silica surface, resulting in fused silica samples with different laser damage performance. Non-destructive test methods such as UV laser-induced fluorescence imaging and photo-thermal deflection were used to characterize the surface defects that contribute to the absorption of UV laser radiation. Our results indicate that the two methods can quantitatively distinguish differences in the distribution of absorptive defects in fused silica samples subjected to different post-processing steps. The percentage of fluorescence defects and the weak absorption coefficient were strongly related to the damage threshold and damage density of fused silica optics, as confirmed by the correlation curves built from statistical analysis of experimental data. The results show that non-destructive evaluation methods such as laser-induced fluorescence and photo-thermal absorption can be effectively applied to estimate the damage performance of fused silica optics at 351 nm pulse laser radiation. This indirect evaluation method is effective for laser damage performance assessment of fused silica optics prior to utilization.

  17. Fiabilité des structures mécaniques adaptatives: effet de la panne des actionneurs ou des capteurs sur la stabilité

    NASA Astrophysics Data System (ADS)

    Fall, H.; Charon, W.; Kouta, R.

    2002-12-01

    Ces dernières décennies, des activités significatives dans le monde étaient dirigées autour du contrôle actif. Le but de ces recherches était essentiellement d'améliorer les performances, la fiabilité et la sécurité des systèmes. Notamment dans le cas des structures soumises à des vibrations aléatoires. D'importants travaux ont été consacré à l'utilisation des “matériaux intelligents” comme capteurs et actionneurs. Cette article propose l'analyse de la fiabilité des systèmes mécaniques en étudiant les pannes des actionneurs ou des capteurs. L'effet de ces pannes sur la stabilité et la performance du système y est démontré. Les méthodologies de conception y sont rappelées. Des exemples numériques sont fournis à travers le contrôle d'un panneau sous chargement dynamique pour illustrer la méthode proposée.

  18. Evaluation of 2.1μm DFB lasers for space applications

    NASA Astrophysics Data System (ADS)

    Barbero, J.; López, D.; Esquivias, I.; Tijero, J. M. G.; Fischer, M.; Roessner, K.; Koeth, J.; Zahir, M.

    2017-11-01

    This paper presents the results obtained in the frame of an ESA-funded project called "Screening and Preevaluation of Shortwave Infrared Laser Diode for Space Application" with the objective of verifying the maturity of state of the art SWIR DFB lasers at 2.1μm to be used for space applications (mainly based on the occultation measurement principle and spectroscopy). The paper focus on the functional and environmental evaluation test plan. It includes high precision characterization, mechanical test (vibration and SRS shocks), thermal cycling, gamma and proton radiation tests, life test and some details of the Destructive Physical Analysis performed. The electro-optical characterization includes measurements of the tuning capabilities of the laser both by current and by temperature, the wavelength stability and the optical power versus laser current.

  19. Laser Plasma Microthruster Performance Evaluation

    NASA Astrophysics Data System (ADS)

    Luke, James R.; Phipps, Claude R.

    2003-05-01

    The micro laser plasma thruster (μLPT) is a sub-kilogram thruster that is capable of meeting the Air Force requirements for the Attitude Control System on a 100-kg class small satellite. The μLPT uses one or more 4W diode lasers to ablate a solid fuel, producing a jet of hot gas or plasma which creates thrust with a high thrust/power ratio. A pre-prototype continuous thrust experiment has been constructed and tested. The continuous thrust experiment uses a 505 mm long continuous loop fuel tape, which consists of a black laser-absorbing fuel material on a transparent plastic substrate. When the laser is operated continuously, the exhaust plume and thrust vector are steered in the direction of the tape motion. Thrust steering can be avoided by pulsing the laser. A torsion pendulum thrust stand has been constructed and calibrated. Many fuel materials and substrates have been tested. Best performance from a non-energetic fuel material was obtained with black polyvinyl chloride (PVC), which produced an average of 70 μN thrust and coupling coefficient (Cm) of 190 μN/W. A proprietary energetic material was also tested, in which the laser initiates a non-propagating detonation. This material produced 500 μN of thrust.

  20. Evaluation of surface topography of zirconia ceramic after Er:YAG laser etching.

    PubMed

    Turp, Volkan; Akgungor, Gokhan; Sen, Deniz; Tuncelli, Betul

    2014-10-01

    The aim of this study is to evaluate the effect of Erbium: yttrium-aluminum-garnet (Er:YAG) laser with different pulse lengths on the surface roughness of zirconia ceramic and airborne particle abrasion. Er:YAG laser treatment is expected to be an alternative surface treatment method for zirconia ceramics; however, the parameters and success of the application are not clear. One hundred and forty zirconia discs (diameter, 10 mm; thickness, 1.2 mm) were prepared by a computer-aided design and computer-aided manufacturing (CAD/CAM) system according to the manufacturer's instructions. Specimens were divided into 14 groups (n=10). One group was left as polished control, one group was air-particle abraded with Al2O3 particles. For the laser treatment groups, laser irradiation was applied at three different pulse energy levels (100, 200, and 300 mJ) and for each energy level at four different pulse lengths; 50, 100, 300, and 600 μs. Surface roughness was evaluated with an optical profilometer and specimens were evaluated with scanning electron microscopy (SEM). Data was analyzed with one way ANOVA and Tukey multiple comparison tests (α=0.05). For the 100 and 200 mJ laser etching groups, 50 and 100 μs laser duration resulted in significantly higher surface roughness compared with air-particle abrasion (p<0.05). The difference among Ra values of 300 μs, 600 μs, and air-particle abrasion groups were not statistically significant (p>0.05). For the 300 mJ laser etching groups; there was no statistically significant difference among the Ra values of 50 μs, 100 μs, 300 μs, 600 μs, and air-particle abrasion groups (p>0.05). In order to increase surface roughness and promote better bonding to resin luting agents, Er:YAG laser etching may be an alternative to air-particle abrasion for zirconia ceramics. However, high levels of pulse energy and longer pulse length may have an adverse effect on micromechanical locking properties, because of a

  1. Developpement des betons semi autoplacants a rheologie adaptee pour des infrastructures

    NASA Astrophysics Data System (ADS)

    Sotomayor Cruz, Cristian Daniel

    Au cours des dernières décennies, les infrastructures canadiennes et québécoises comportent plusieurs structures en béton armé présentant des problèmes de durabilité dus aux conditions climatiques sévères, à la mauvaise conception des structures, à la qualité des matériaux, aux types des bétons choisis, aux systèmes de construction ou à l'existence d'événements incontrôlables. En ce qui concerne le choix du béton pour la construction des infrastructures, une vaste gamme de béton divisée en deux principaux types peut être utilisée: le béton conventionnel vibré (BCV) et le béton autoplaçant (BAP). Dans le cas d'un BCV, la consolidation inadéquate par vibration a été un problème récurrent, occasionnant des dommages structuraux. Ceci a conduit à une réduction de la durabilité et à une augmentation du coût d'entretien et de réparation des infrastructures. Rien que l'utilisation d'un BAP a des avantages tels que l'élimination de la vibration, la réduction des coûts de main d'oeuvre et l'amélioration de la qualité des structures, néanmoins, le coût initial d'un BAP par rapport à un BCV ne permet pas encore de généraliser son utilisation dans l'industrie de la construction. Ce mémoire présente la conception d'une nouvelle gamme de béton semi-autoplaçant pour la construction des infrastructures (BSAP-I) exigeant une vibration minimale. Il s'agit de trouver un équilibre optimal entre la rhéologie et le coût initial du nouveau béton pour conférer une bonne performance structurale et économique aux structures. Le programme expérimental établi a premièrement permis d'évaluer la faisabilité d'utilisation des BSAP-I pour la mise en place des piliers d'une infrastructure de pont à Sherbrooke. En plus, l'utilisation d'un plan d'expériences a permis l'évaluation de trois paramètres de formulation sur les propriétés des mélanges de BSAP-I à l'état frais et durci. Finalement, l'évaluation de la performance des

  2. In Vitro Evaluation of Dentin Hydraulic Conductance After 980 nm Diode Laser Irradiation.

    PubMed

    Rizzante, Fabio A P; Maenosono, Rafael M; Duarte, Marco A H; Furuse, Adilson Y; Palma-Dibb, Regina G; Ishikiriama, Sérgio K

    2016-03-01

    Dentin hypersensitivity treatments are based on the physical obliteration of the dentinal tubules to reduce hydraulic conductance. The aim of the present study is to evaluate the hydraulic conductance of bovine root dentin after irradiation with a 980-nm diode laser, with or without associated fluoride varnish. Sixty bovine root dentin specimens were divided into six groups (n = 10 in each group): G1, G3, and G5 (0.5 W, 0.7 W, and 1 W diode laser, respectively); G2, G4, and G6 (fluoride varnish application + 0.5 W, 0.7 W, and 1 W diode laser, respectively). The dentin hydraulic conductance was evaluated at four time periods with a fluxmeter: 1) with smear layer, 2) after 37% phosphoric acid etching, 3) after the treatments, and 4) after 6% citric acid challenge. After the dentinal fluid flow measurements, specimens were also evaluated for mineral composition using energy dispersive X-ray spectroscopy (EDS). Analysis demonstrated a better result with increased irradiation power (P < 0.001), especially if the diode laser irradiation was associated with the application of fluoride varnish (P < 0.001), ensuring a greater reduction in permeability. Considering the groups treated only with laser irradiation, the 1 W group was superior when compared with the 0.5 W and 0.7 W irradiated groups immediately after treatment (P < 0.001). After citric acid testing, all groups showed similar results, except when comparing the 1 W groups with the 0.5 W groups (P = 0.04). EDS results of the irradiated groups showed an increase in the proportion of calcium and phosphorus ions, which demonstrates a superficial composition modification after laser treatments. Laser irradiation of exposed dentin promoted significant reduction in the dentin hydraulic conductance, mainly with higher energy densities and association with fluoride varnish.

  3. Paternité des articles et intérêts concurrents : une analyse des recommandations aux auteurs des journaux traitant de pratique pharmaceutique

    PubMed Central

    Courbon, Ève; Tanguay, Cynthia; Lebel, Denis; Bussières, Jean-François

    2014-01-01

    RÉSUMÉ Contexte : La présence d’auteurs honorifiques et fantômes ainsi que les intérêts concurrents représentent des difficultés bien documentées, liées à la publication d’articles scientifiques. Il existe des lignes directrices encadrant la rédaction et la publication de manuscrits scientifiques, notamment celles de l’International Committee of Medical Journal Editors (ICMJE). Objectifs : L’objectif principal de cette étude descriptive et transversale visait à recenser les instructions portant sur la paternité des articles et les intérêts concurrents provenant des recommandations aux auteurs des journaux traitant de pratique pharmaceutique. L’objectif secondaire visait à déterminer des mesures correctrices pour une paternité des articles plus transparente. Méthode : La recherche a débuté par l’identification des journaux traitant de pratique pharmaceutique. La consultation des instructions aux auteurs des journaux a permis ensuite de recenser les recommandations destinées à éviter les problèmes de paternité des articles et d’intérêts concurrents. Finalement, les membres de l’équipe de recherche se sont consultés afin de définir des mesures correctrices possibles à l’intention des chercheurs. Résultats : Des 232 journaux traitant de pharmacie, 33 ont été définis comme traitant de pratique pharmaceutique. Un total de 24 (73 %) journaux mentionnaient suivre la politique de l’ICMJE, 14 (42 %) demandaient aux auteurs de remplir un formulaire de déclaration d’intérêts concurrents au moment de la soumission de l’article, 17 (52 %) présentaient une définition de la qualité d’auteur et 5 (15 %) demandaient de détailler les contributions de chaque auteur. Une grille de 40 critères a été élaborée pour définir l’attribution du statut d’auteur. Conclusion : Moins de la moitié des journaux demandait aux auteurs de transmettre un formulaire de déclaration des intérêts concurrents au moment de la

  4. Evaluation and design of non-lethal laser dazzlers utilizing microcontrollers

    NASA Astrophysics Data System (ADS)

    Richardson, Keith Jack

    Current non-lethal weapons suffer from an inability to meet requirements for uses across many fields and purposes. The safety and effectiveness of these weapons are inadequate. New concepts have provided a weapon utilizing lasers to flashblind a target's visual system. Minimal research and testing have been conducted to investigate the efficiency and safety of these weapons called laser dazzlers. Essentially a laser dazzler is comprised of a laser beam that has been diverged with the use of a lens to expand the beam creating an intensely bright flashlight. All laser dazzlers to date are incapable of adjusting to external conditions automatically. This is important, because the power of these weapons need to change according to distance and light conditions. At long distances, the weapon is rendered useless because the laser beam has become diluted. At near distances, the weapon is too powerful causing permanent damage to the eye because the beam is condensed. Similarly, the eye adapts to brightness by adjusting the pupil size, which effectively limits the amount of light entering the eye. Laser eye damage is determined by the level of irradiance entering the eye. Therefore, a laser dazzler needs the ability to adjust output irradiance to compensate for the distance to the target and ambient light conditions. It was postulated if an innovative laser dazzler design could adjust the laser beam divergence then the irradiance at the eye could be optimized for maximum vision disruption with minimal risk of permanent damage. The young nature of these weapons has lead to the rushed assumptions of laser wavelengths (color) and pulsing frequencies to cause maximum disorientation. Research provided key values of irradiance, wavelength, pulsing frequency and functions for the optical lens system. In order for the laser dazzler to continuously evaluate the external conditions, luminosity and distance sensors were incorporated into the design. A control system was devised to

  5. Non-Contact Laser Based Ultrasound Evaluation of Canned Foods

    NASA Astrophysics Data System (ADS)

    Shelton, David

    2005-03-01

    Laser-Based Ultrasound detection was used to measure the velocity of compression waves transmitted through canned foods. Condensed broth, canned pasta, and non-condensed soup were evaluated in these experiments. Homodyne adaptive optics resulted in measurements that were more accurate than the traditional heterodyne method, as well as yielding a 10 dB gain in signal to noise. A-Scans measured the velocity of ultrasound sent through the center of the can and were able to distinguish the quantity of food stuff in its path, as well as distinguish between meat and potato. B-Scans investigated the heterogeneity of the sample’s contents. The evaluation of canned foods was completely non-contact and would be suitable for continuous monitoring in production. These results were verified by conducting the same experiments with a contact piezo transducer. Although the contact method yields a higher signal to noise ratio than the non-contact method, Laser-Based Ultrasound was able to detect surface waves the contact transducer could not.

  6. La participation des enfants et des adolescents à la boxe

    PubMed Central

    Purcell, Laura K; LeBlanc, Claire MA

    2012-01-01

    RÉSUMÉ Des milliers de garçons et de filles de moins de 19 ans font de la boxe en Amérique du Nord. Même si la boxe comporte des avantages pour ceux qui y participent, y compris l’exercice, l’autodiscipline et la confiance en soi, le sport lui-même favorise et récompense des coups délibérés à la tête et au visage. Les personnes qui font de la boxe risquent de subir des blessures à la tête, au visage et au cou, y compris des traumatismes neurologiques chroniques et même fatals. Les commotions cérébrales sont l’une des principales blessures causées par la boxe. En raison du risque de blessures crâniennes et faciales, la Société canadienne de pédiatrie et l’American Academy of Pediatrics s’opposent vigoureusement à la boxe comme activité sportive pour les enfants et les adolescents. Ces organismes recommandent que les médecins s’élèvent contre la boxe auprès des jeunes et les encouragent à participer à d’autres activités dans lesquelles les coups intentionnels à la tête ne constituent pas un élément essentiel du sport.

  7. Evaluation de la sécurité du circuit des médicaments anticancéreux dans un hôpital régional en Tunisie

    PubMed Central

    Sahli, Jihène; El Ghardallou, Meriam; Bougmiza, Iheb; Henchiri, Besma; Limam, Manel; Mejdoub, Rim; Mtiraoui, Ali; Ajmi, Thouraya

    2016-01-01

    Introduction Parmi les événements indésirables, ceux liés au circuit des médicaments occupent une place importante et risquent de causer un préjudice grave aux patients. Dans ce contexte, nous avons mené cette étude dans l'optique de décrire et d’évaluer le circuit des médicaments anticancéreux dans un hôpital régional tunisien. Méthodes Il s'agit d'une étude évaluative du risque lié aux médicaments anticancéreux, type « visite de risque » menée sur une période de 15 jours au cours de l'année 2014 au service de cancérologie de l'hôpital régional de Gafsa (Tunisie). Cette méthode d’évaluation est inspirée de celle conduite par le projet « SECURIMED » développé par le Comité de Coordination de l'Evaluation Clinique et de la Qualité en Aquitaine (CCECQA), en France. Résultats Dans notre étude, l'observation du circuit des médicaments anticancéreux a révélé certaines insuffisances. On a noté que la répartition des missions des différents acteurs est sujette parfois à des glissements de tâches. Un manque important ainsi que une inadéquation aux normes au niveau des équipements nécessaires pour la préparation et la protection des professionnels manipulant ces médicaments ont été également décelés. Conclusion La sécurisation du circuit des médicaments devrait être une priorité inscrite dans l'ensemble des démarches nationales et partagée par tous les intervenants et ce dans l'optique d'atteindre un objectif prémium: la qualité de la prise en charge globale et la sécurité des patients. PMID:27200135

  8. Laser femtoseconde, filamentation, nuage et orage

    NASA Astrophysics Data System (ADS)

    Courvoisier, F.; Boutou, V.; Kasparian, J.; Salmon, E.; Méjean, G.; Yu, J.; Wolf, J.-P.

    2005-06-01

    Les applications telles que le contrôle de foudre grâce aux filaments autoguidés générés par un laser femtoseconde nécessitent de propager un tel filament à travers des aérosols de gouttes d'eau. Nous montrons qu'un filament survit à son interaction avec une goutte de diamètre comparable au sien (95 μ m), ainsi qu'à des nuages d'épaisseur optique 3,2, soit 5% de transmission. Cette transmission est permise par la présence d'un “bain de photons” autour du filament. Ce bain forme un réservoir contenant une part importante de l'énergie du faisceau, en équilibre avec le filament, et favorisant son alimentation.

  9. Membrane fluidization by alcohols inhibits DesK-DesR signalling in Bacillus subtilis.

    PubMed

    Vaňousová, Kateřina; Beranová, Jana; Fišer, Radovan; Jemioła-Rzemińska, Malgorzata; Matyska Lišková, Petra; Cybulski, Larisa; Strzałka, Kazimierz; Konopásek, Ivo

    2018-03-01

    After cold shock, the Bacillus subtilis desaturase Des introduces double bonds into the fatty acids of existing membrane phospholipids. The synthesis of Des is regulated exclusively by the two-component system DesK/DesR; DesK serves as a sensor of the state of the membrane and triggers Des synthesis after a decrease in membrane fluidity. The aim of our work is to investigate the biophysical changes in the membrane that are able to affect the DesK signalling state. Using linear alcohols (ethanol, propanol, butanol, hexanol, octanol) and benzyl alcohol, we were able to suppress Des synthesis after a temperature downshift. The changes in the biophysical properties of the membrane caused by alcohol addition were followed using membrane fluorescent probes and differential scanning calorimetry. We found that the membrane fluidization induced by alcohols was reflected in an increased hydration at the lipid-water interface. This is associated with a decrease in DesK activity. The addition of alcohol mimics a temperature increase, which can be measured isothermically by fluorescence anisotropy. The effect of alcohols on the membrane periphery is in line with the concept of the mechanism by which two hydrophilic motifs located at opposite ends of the transmembrane region of DesK, which work as a molecular caliper, sense temperature-dependent variations in membrane properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. In-vitro and clinical evaluation of transurethral laser-induced prostatectomy (TULIP)

    NASA Astrophysics Data System (ADS)

    van Swol, Christiaan F. P.; Verdaasdonck, Rudolf M.; Mooibroek, Jaap; Boon, Tom A.

    1993-05-01

    Transurethral ultrasound-guided laser induced prostatectomy (TULIP) is a recent development in the treatment of benign prostatic hyperplasia. The system is based upon Nd:YAG laser irradiation delivered by a right angled fiber. The dosimetry used in a clinical situation is mostly based upon animal studies. In this study, the light and temperature distribution in the prostate during Nd:YAG laser irradiation were modeled using Monte Carlo and finite differences theory. The results of this model were compared with in vitro experiments. The influence of the different parameters involved, e.g., the scanning speed and the power of the laser beam, were evaluated. Initial results show the temperature distribution and thus the therapeutic effect of the TULIP procedure. Until now 36 patients have been treated successfully. The mean in-hospital time was somewhat shorter than for a TURP treatment while the results were comparable. These treatments, however, show the need for a better understanding of the mechanisms involved. Modeling and subsequent in vitro and in vivo measurements might improve the understanding and safe and successful application of prostate treatment using laser based systems.

  11. Etude du processus de changement vecu par des familles ayant decide d'adopter volontairement des comportements d'attenuation des changements climatiques

    NASA Astrophysics Data System (ADS)

    Leger, Michel T.

    Les activites humaines energivores telles l'utilisation intensive de l'automobile, la surconsommation de biens et l'usage excessif d'electricite contribuent aux changements climatiques et autres problemes environnementaux. Bien que plusieurs recherches rapportent que l'etre humain est de plus en plus conscient de ses impacts sur le climat de la planete, ces memes recherches indiquent qu'en general, les gens continuent a se comporter de facon non ecologique. Que ce soit a l'ecole ou dans la communaute, plusieurs chercheurs en education relative a l'environnement estiment qu'une personne bien intentionnee est capable d'adopter des comportements plus respectueux de l'environnement. Le but de cette these etait de comprendre le processus d'integration de comportements d'attenuation des changements climatiques dans des familles. A cette fin, nous nous sommes fixe deux objectifs : 1) decrire les competences et les procedes qui favorisent l'adoption de comportements d'attenuation des changements climatiques dans des familles et 2) decrire les facteurs et les dynamiques familiales qui facilitent et limitent l'adoption de comportements d'attenuation des changements climatiques dans des familles. Des familles ont ete invitees a essayer des comportements personnels et collectifs d'attenuation des changements climatiques de sorte a integrer des modes de vie plus ecologiques. Sur une periode de huit mois, nous avons suivi leur experience de changement afin de mieux comprendre comment se produit le processus de changement dans des familles qui decident volontairement d'adopter des comportements d'attenuation des changements climatiques. Apres leur avoir fourni quelques connaissances de base sur les changements climatiques, nous avons observe le vecu de changement des familles durant huit mois d'essais a l'aide de journaux reflexifs, d'entretiens d'explicitation et du journal du chercheur. La these comporte trois articles scientifiques. Dans le premier article, nous presentons une

  12. [Evaluation of YAG-laser vitreolysis effectiveness based on quantitative characterization of vitreous floaters].

    PubMed

    Shaimova, V A; Shaimov, T B; Shaimov, R B; Galin, A Yu; Goloshchapova, Zh A; Ryzhkov, P K; Fomin, A V

    2018-01-01

    To develop methods for evaluating effectiveness of YAG-laser vitreolysis of vitreous floaters. The study included 144 patients (173 eyes) who had underwent YAG-laser vitreolysis and were under observation from 01.09.16 to 31.01.18. The patients were 34 to 86 years old (mean age 62.7±10.2 years), 28 (19.4%) patients were male, 116 (80.6%) - female. All patients underwent standard and additional examination: ultrasonography (Accutome B-scan plus, U.S.A.), optic biometry (Lenstar 900, Haag-Streit, Switzerland), spectral optical coherence tomography using RTVue XR Avanti scanner (Optovue, U.S.A.) in modes Enhanced HD Line, 3D Retina, 3D Widefield MCT, Cross Line, Angio Retina, and scanning laser ophthalmoscopy (SLO) using Navilas 577s system. Laser vitreolysis was performed using the Ultra Q Reflex laser (Ellex, Australia). This paper presents methods of objective quantitative and qualitative assessment of artifactual shadows of vitreous floaters with spectral optical coherence tomographic scanner RTVue xR Avanti employing an algorithm of automatic detection of non-perfusion zones in modes Angio Retina, HD Angio Retina, as well as foveal avascular zone (FAZ) measurement with Angio Analytics® software. SLO performed with Navilas 577s was used as method of visualizing floaters and artifactual shadows in retinal surface layers prior to surgical treatment and after YAG-laser vitreolysis. Suggested methods of quantitative and qualitative assessment of artifactual shadows of the floaters in retinal layers are promising and may prove to be highly relevant for clinical monitoring of patients, optimization of treatment indications and evaluating effectiveness of YAG-laser vitreolysis. Further research of laser vitreolysis effectiveness in patients with vitreous floaters is necessary.

  13. The Sixth Omega Laser Facility Users Group Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrasso, R. D.

    A capacity gathering of over 100 researchers from 25 universities and laboratories met at the Laboratory for Laser Energetics (LLE) for the Sixth Omega Laser Facility Users Group (OLUG) workshop. The purpose of the 2.5-day workshop was to facilitate communications and exchanges among individual OMEGA users, and between users and the LLE management; to present ongoing and proposed research; to encourage research opportunities and collaborations that could be undertaken at the Omega Laser Facility and in a complementary fashion at other facilities [such as the National Ignition Facility (NIF) or the Laboratoire pour l’Utilisation des Lasers Intenses (LULI)]; to providemore » an opportunity for students, postdoctoral fellows, and young researchers to present their research in an informal setting; and to provide feedback from the users to LLE management about ways to improve and keep the facility and future experimental campaigns at the cutting edge.« less

  14. The Fifth Omega Laser Facility Users Group Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrasso, R. D.

    A capacity gathering of over 100 researchers from 25 universities and laboratories met at the Laboratory for Laser Energetics (LLE) for the Fifth Omega Laser Facility Users Group (OLUG) workshop. The purpose of the 2.5-day workshop was to facilitate communications and exchanges among individual Omega users and between users and the LLE management; to present ongoing and proposed research; to encourage research opportunities and collaborations that could be undertaken at the Omega Laser Facility and in a complementary fashion at other facilities [such as the National Ignition Facility (NIF) or the Laboratoire pour l’Utilisation des Lasers Intenses (LULI)]; to providemore » an opportunity for students, postdoctoral fellows, and young researchers to present their research in an informal setting; and to provide feedback to LLE management from the users about ways to improve the facility and future experimental campaigns.« less

  15. Laser ektacytometry and evaluation of statistical characteristics of inhomogeneous ensembles of red blood cells

    NASA Astrophysics Data System (ADS)

    Nikitin, S. Yu.; Priezzhev, A. V.; Lugovtsov, A. E.; Ustinov, V. D.; Razgulin, A. V.

    2014-10-01

    The paper is devoted to development of the laser ektacytometry technique for evaluation of the statistical characteristics of inhomogeneous ensembles of red blood cells (RBCs). We have analyzed theoretically laser beam scattering by the inhomogeneous ensembles of elliptical discs, modeling red blood cells in the ektacytometer. The analysis shows that the laser ektacytometry technique allows for quantitative evaluation of such population characteristics of RBCs as the cells mean shape, the cells deformability variance and asymmetry of the cells distribution in the deformability. Moreover, we show that the deformability distribution itself can be retrieved by solving a specific Fredholm integral equation of the first kind. At this stage we do not take into account the scatter in the RBC sizes.

  16. Evaluation of Mechanical Properties of Glass Fiber Posts Subjected to Laser Surface Treatments.

    PubMed

    Barbosa Siqueira, Carolina; Spadini de Faria, Natália; Raucci-Neto, Walter; Colucci, Vivian; Alves Gomes, Erica

    2016-10-01

    The aim of this study was to evaluate the influence of laser irradiation on flexural strength, elastic modulus, and surface roughness and morphology of glass fiber posts (GFPs). Laser treatment of GFPs has been introduced to improve its adhesion properties. A total of 40 GFPs were divided into 4 groups according to the irradiation protocol: GC-no irradiation, GYAG-irradiation with erbium:yttrium-aluminum-garnet [Er:YAG], GCR-irradiation with erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG), and GDI-irradiation with diode laser. The GFP roughness and morphology were evaluated through laser confocal microscopy before and after surface treatment. Three-point bending flexural test measured flexural strength and elastic modulus. Data about elastic modulus and flexural strength were subjected to one-way ANOVA and Bonferroni test (p < 0.05). The effect of roughness was evaluated using the linear mixed effects model and Bonferroni test (p < 0.05). Laser treatment changed surface roughness in the groups GCR (p = 0.000) and GDI (p = 0.007). The mean flexural strength in GYAG (995.22 MPa) was similar to that in GC (980.48 MPa) (p = 1.000) but different from that in GCR (746.83 MPa) and that in GDI (691.34 MPa) (p = 0.000). No difference was found between the groups GCR and GDI (p = 0.86). For elastic modulus: GYAG (24.47 GPa) was similar to GC (25.92 GPa) (p = 1.000) but different from GCR (19.88 GPa) (p = 0.002) and GDI (17.20 GPa) (p = 0.000). The different types of lasers, especially Er,Cr:YSGG and 980 ηm diode, influenced the mechanical properties of GFPs.

  17. In vitro histological evaluation of the surgical margins made by different laser wavelengths in tongue tissues

    PubMed Central

    Azevedo, Ana-Salvaterra; Ferreira, Fernando; Delgado, Maria-Leonor; Garcês, Fernanda; Carreira, Sofia; Martins, Marco; Suarez-Quintanilla, Juan

    2016-01-01

    Background Lasers have become standard tools for the surgical treatment of oral lesions. The purpose of this study is to determine the surgical margins and histologically evaluate the tissue thermal effects induced by different types of surgical instruments. Material and Methods Cuts were made in pork tongues’ mucosa with different lasers (Er:YAG at 2W with and without air / water spray and at 4W with and without air / water spray; CO2 at 3.5W and 7W in pulsed mode and at 7W in continuous mode; the diode laser at 3.5W and boost 3.5W in pulsed mode; Nd:YAG at 6W, 40Hz and electroscalpel at 5W and conventional scalpel as control. Macroscopic and microscopic morphological changes were evaluated. Results The results of this study showed that the surgical instruments that caused greater tissue damage extension were: the Nd:YAG laser (670.68μm), the diode 3.5W and boost PW (626.82μm), the CO2 7W CW (571.18μm), the CO2 at 7W PW (485.45μm), the diode 3.5W PW (456.15μm), the electroscalpel (409.57μm) and lastly the CO2 laser 3.5W PW (306.19μm) and Er:YAG (74.66μm) laser, regardless of power, mode or air / water spray used. An association between the Tissue Damage Extension and the Degree of Carbonization (r = 0.789; P = 0.01), and an association between the Tissue Damage Extension and Regularity of the Incision were found (r = -, 299; P = 0.01). Conclusions The results of this study suggest that lasers can be used in soft tissues biopsies of the oral cavity, enabling a correct histopathological analysis, as long as the biological effects of each laser type are considered. The Er:YAG laser revealed its potential for biopsies of the oral mucosa ensuring a successful histological evaluation and the CO2 laser at 3,5W in pulsed mode presented itself as the best choice for surgeries with hemostasis. Key words:CO2 laser, diode laser, Er:YAG laser, laser surgery, Nd:YAG laser, oral mucosa, thermal effect. PMID:27703606

  18. Des ballons pour demain

    NASA Astrophysics Data System (ADS)

    Régipa, R.

    A partir d'une théorie sur la détermination des formes et des contraintes globales d'un ballon de révolution, ou s'en rapprochant, une nouvelle famille de ballons a été définie. Les ballons actuels, dits de ``forme naturelle'', sont calculés en général pour une tension circonférencielle nulle. Ainsi, pour une mission donnée, la tension longitudinale et la forme de l'enveloppe sont strictement imposées. Les ballons de la nouvelle génération sont globalement cylindriques et leurs pôles sont réunis par un câble axial, chargé de transmettre une partie des efforts depuis le crochet (pôle inférieur), directement au pôle supérieur. De plus, la zone latérale cylindrique est soumise à un faible champ de tensions circonférencielles. Ainsi, deux paramètres permettent de faire évoluer la distribution des tensions et la forme de l'enveloppe: - la tension du câble de liaison entre pôles (ou la longueur de ce câble) - la tension circonférencielle moyenne désirée (ou le rayon du ballon). On peut donc calculer et réaliser: - soit des ballons de forme adaptée, comme les ballons à fond plat pour le bon fonctionnement des montgolfières infrarouge (projet MIR); - soit des ballons optimisés pour une bonne répartition des contraintes et une meilleure utilisation des matériaux d'enveloppe, pour l'ensemble des programmes stratosphériques. Il s'ensuit une économie sensible des coûts de fabrication, une fiabilité accrue du fonctionnement de ces ballons et une rendement opérationnel bien supérieur, permettant entre autres, d'envisager des vols à très haute altitude en matériaux très légers.

  19. Diethylstilbestrol (DES) and Cancer

    MedlinePlus

    ... Genetics Services Directory Cancer Prevention Overview Research Diethylstilbestrol (DES) and Cancer On This Page What is DES? ... outlined in the table below. Fertility Problems in DES Daughters ( 7 ) Fertility Complication Hazard Ratio Percent Cumulative ...

  20. Maladie des vibrations

    PubMed Central

    Shen, Shixin (Cindy); House, Ronald A.

    2017-01-01

    Résumé Objectif Permettre aux médecins de famille de comprendre l’épidémiologie, la pathogenèse, les symptômes, le diagnostic et la prise en charge de la maladie des vibrations, une maladie professionnelle importante et courante au Canada. Sources d’information Une recherche a été effectuée sur MEDLINE afin de relever les recherches et comptes rendus portant sur la maladie des vibrations. Une recherche a été effectuée sur Google dans le but d’obtenir la littérature grise qui convient au contexte canadien. D’autres références ont été tirées des articles relevés. Message principal La maladie des vibrations est une maladie professionnelle répandue touchant les travailleurs de diverses industries qui utilisent des outils vibrants. La maladie est cependant sous-diagnostiquée au Canada. Elle compte 3 éléments : vasculaire, sous la forme d’un phénomène de Raynaud secondaire; neurosensoriel; et musculosquelettique. Aux stades les plus avancés, la maladie des vibrations entraîne une invalidité importante et une piètre qualité de vie. Son diagnostic exige une anamnèse minutieuse, en particulier des antécédents professionnels, un examen physique, des analyses de laboratoire afin d’éliminer les autres diagnostics, et la recommandation en médecine du travail aux fins d’investigations plus poussées. La prise en charge consiste à réduire l’exposition aux vibrations, éviter les températures froides, abandonner le tabac et administrer des médicaments. Conclusion Pour assurer un diagnostic rapide de la maladie des vibrations et améliorer le pronostic et la qualité de vie, les médecins de famille devraient connaître cette maladie professionnelle courante, et pouvoir obtenir les détails pertinents durant l’anamnèse, recommander les patients aux cliniques de médecine du travail et débuter les demandes d’indemnisation de manière appropriée. PMID:28292812

  1. Femtosecond laser beam propagation through corneal tissue: Evaluation of therapeutic laser-stimulated second and third- harmonic generation

    NASA Astrophysics Data System (ADS)

    Calhoun, William R., III

    One of the most recent advancements in laser technology is the development of ultrashort pulsed femtosecond lasers (FSLs). FSLs are improving many fields due to their unique extreme precision, low energy and ablation characteristics. In the area of laser medicine, ophthalmic surgeries have seen very promising developments. Some of the most commonly performed surgical operations in the world, including laser-assisted in-situ keratomileusis (LASIK), lens replacement (cataract surgery), and keratoplasty (cornea transplant), now employ FSLs for their unique abilities that lead to improved clinical outcome and patient satisfaction. The application of FSLs in medical therapeutics is a recent development, and although they offer many benefits, FSLs also stimulate nonlinear optical effects (NOEs), many of which were insignificant with previously developed lasers. NOEs can change the laser characteristics during propagation through a medium, which can subsequently introduce unique safety concerns for the surrounding tissues. Traditional approaches for characterizing optical effects, laser performance, safety and efficacy do not properly account for NOEs, and there remains a lack of data that describe NOEs in clinically relevant procedures and tissues. As FSL technology continues to expand towards new applications, FSL induced NOEs need to be better understood in order to ensure safety as FSL medical devices and applications continue to evolve at a rapid pace. In order to improve the understanding of FSL-tissue interactions related to NOEs stimulated during laser beam propagation though corneal tissue, research investigations were conducted to evaluate corneal optical properties and determine how corneal tissue properties including corneal layer, collagen orientation and collagen crosslinking, and laser parameters including pulse energy, repetition rate and numerical aperture affect second and third-harmonic generation (HG) intensity, duration and efficiency. The results of

  2. Etat des lieux des soins de premier recours des malades mentaux à Antananarivo : étude rétrospective

    PubMed Central

    Bakohariliva, Hasina Andrianarivony; Rafehivola, Imisanavalona Hanitrinihaja; Raobelle, Evah Norotiana; Raharivelo, Adeline; Rajaonarison, Bertille Hortense

    2018-01-01

    Résumé Religion et guérisseurs traditionnels occupent encore une place prépondérante dans la prise en charge des maladies mentales à Madagascar. Ainsi, nous nous sommes fixés comme objectif d'établir un état des lieux sur les soins de premier recours des malades mentaux. Nous avons mené une étude rétrospective descriptive s'étalant sur une période de 16 mois allant de janvier 2014 en avril 2015 au sein du service de psychiatrie du CHU de Befelatanana à Antananarivo. La prévalence des psychoses était de 25%. Le genre féminin (53%), l'ethnie merina (77%), les étudiants (45%), le niveau d'étude secondaire (40%), les célibataires (72%), la religion protestante (45%), ainsi que le niveau socio-économique moyen (57,5%) étaient prédominants. Dans les paramètres cliniques, le mode de début brutal (52%), le premier recours à la religion (40%), la présence d'antécédents des cas similaire (90%), étaient majoritaires. La schizophrénie était la pathologie la plus rencontrée dans la moitié des cas. Le délai d'amélioration en cas de traitement religieux et traditionnels était dans la moitié des cas de plus de 10 jours d'hospitalisation. Les patients ayant reçu une prise en charge psychiatrique en premier recours, étaient améliorés dans 75 % cas en moins de 10jours. Le retard du recours aux soins psychiatriques est une réalité à Madagascar qui aggrave le pronostic des psychoses. PMID:29632623

  3. Evaluation of laser cutting process with auxiliary gas pressure by soft computing approach

    NASA Astrophysics Data System (ADS)

    Lazov, Lyubomir; Nikolić, Vlastimir; Jovic, Srdjan; Milovančević, Miloš; Deneva, Heristina; Teirumenieka, Erika; Arsic, Nebojsa

    2018-06-01

    Evaluation of the optimal laser cutting parameters is very important for the high cut quality. This is highly nonlinear process with different parameters which is the main challenge in the optimization process. Data mining methodology is one of most versatile method which can be used laser cutting process optimization. Support vector regression (SVR) procedure is implemented since it is a versatile and robust technique for very nonlinear data regression. The goal in this study was to determine the optimal laser cutting parameters to ensure robust condition for minimization of average surface roughness. Three cutting parameters, the cutting speed, the laser power, and the assist gas pressure, were used in the investigation. As a laser type TruLaser 1030 technological system was used. Nitrogen as an assisted gas was used in the laser cutting process. As the data mining method, support vector regression procedure was used. Data mining prediction accuracy was very high according the coefficient (R2) of determination and root mean square error (RMSE): R2 = 0.9975 and RMSE = 0.0337. Therefore the data mining approach could be used effectively for determination of the optimal conditions of the laser cutting process.

  4. Photoémission de Csl induite par une impulsion laser intense femtoseconde

    NASA Astrophysics Data System (ADS)

    Belsky, A.; Vasil'Ev, A.; Yatsenko, B.; Bachau, H.; Martin, P.; Geoffroy, G.; Guizard, S.

    2003-06-01

    Nous avons mesuré pour la première fois les spectres de photoélectrons émis par un cristal isolant à large bande interdite, Csl, avec une dynamique de 10^6 coups/s, excité par la source laser haute cadence du C.E.L.I.A (800 nm, 40 fs, 1 kHz, 1 TW). L'émission d'électrons jusqu'à des énergies de quelques dizaines d'électrons-volts a été observée pour des impulsions d'éclairement compris entre 0.5 et 3 TW/cm^2, relativement faible donc par comparaison aux éclairements utilisés pour accélérer les électrons d'un atome aux mêmes énergies. Ces spectres contiennent tous, en particulier, deux bandes dans le domaine des basses énergies d'électrons (<5 eV), également observées lors d'études précédentes. Les électrons les plus énergétiques forment un plateau intense légèrement structuré et limité par une coupure exponentielle. Pour des impulsions de 3 TW/cm^2 cette coupure est située à 27 eV. L'insuffisance du mécanisme électron-photon-phonon, considéré jusqu'à présent comme le principal processus d'échauffement des électrons dans les solides en interaction non destructrice avec un champ laser, nous a poussé à proposer un mécanisme alternatif. Ce modèle met en évidence les transitions directes multiphotoniques dans la bande de conduction du solide qui sont incontournables du fait de sa structure électronique multi-branches

  5. New alternatives for laser vaporization of the prostate: experimental evaluation of a 980-, 1,318- and 1,470-nm diode laser device.

    PubMed

    Wezel, Felix; Wendt-Nordahl, Gunnar; Huck, Nina; Bach, Thorsten; Weiss, Christel; Michel, Maurice Stephan; Häcker, Axel

    2010-04-01

    Several diode laser systems were introduced in recent years for the minimal-invasive surgical therapy of benign prostate enlargement. We investigated the ablation capacities, hemostatic properties and extend of tissue necrosis of different diode lasers at wavelengths of 980, 1,318 and 1,470 nm and compared the results to the 120 W GreenLight HPS laser. The laser devices were evaluated in an ex vivo model using isolated porcine kidneys. The weight difference of the porcine kidneys after 10 min of laser vaporization defined the amount of ablated tissue. Blood loss was measured in blood-perfused kidneys following laser vaporization. Histological examination was performed to assess the tissue effects. The side-firing 980 and 1,470 nm diode lasers displayed similar ablative capacities compared to the GreenLight HPS laser (n.s.). The 1,318-nm laser, equipped with a bare-ended fiber, reached a higher ablation rate compared to the other laser devices (each P < 0.05). A calculated 'output power efficiency per watt' revealed that the 1,318-nm laser with a bare-ended fiber reached the highest rate compared to the side-firing devices (each P < 0.0001). All three diode lasers showed superior hemostatic properties compared to the GreenLight HPS laser (each P < 0.01). The extend of morphological tissue necrosis was 4.62 mm (1,318 nm), 1.30 mm (1,470 nm), 4.18 mm (980 nm) and 0.84 mm (GreenLight HPS laser), respectively. The diode lasers offered similar ablative capacities and improved hemostatic properties compared to the 120 W GreenLight HPS laser in this experimental ex vivo setting. The higher tissue penetration of the diode lasers compared to the GreenLight HPS laser may explain improved hemostasis.

  6. Evaluation of the cavity margins after Er:YAG laser ablation of the enamel and dentin

    NASA Astrophysics Data System (ADS)

    Dostalova, Tatjana; Krejsa, Otakar; Jelinkova, Helena; Hamal, Karel

    1994-12-01

    This study investigates the checks of cavity margin after enamel and dentin ablation. The Er:YAG laser enamel and dentin ablation can be directly connected with the danger of cracks originating in the enamel near the cavity. This study evaluates the quality of the enamel edges after Er:YAG laser preparation. The enamel and dentin of buccal surfaces were ablated by the Er:YAG laser radiation. An Erbium:YAG laser system with the energy of 200 mJ was used to generate 200 microsecond(s) long pulses of mid-infrared 2.94 micrometers light in multimode configuration. The laser was operating in a free running mode, the repetition rate being 0.5 Hz with average laser power of 100 mW. Laser radiation was focused on the tooth tissue. Water cooling was used during the procedure in order to prevent tooth tissue destruction. The time of laser preparation was 5 minutes. A cavity of class V was prepared. The teeth were immersed into 0.5% basic fuchsin and then centrifuged at 6000 rev/min for 20 minutes. The microphotographs of the margins stained with 0.5% basic fuchsin were made and then the longitudinal section of the teeth were evaluated. The micrographs of the longitudinal section were checked and measured afterwards. The effect of the investigated laser irradiation on the origin of cracks was analyzed in the scanning electron microscope. Micrographs of each tooth before and after the laser ablation were compared. Micrographs of the intact teeth after extraction present the cracks of the enamel. They depend on the pressure exerted during extraction. The influence of the laser ablation proper is it bears no signs of new cracks. The conclusions of this study demonstrate the non-invasive nature of the Er:YAG laser ablation of the hard dental tissues.

  7. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    PubMed

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels <3 mm in diameter. We analyzed the impact of stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; P<.001). The benefit of a DES compared to a BMS regarding ISR was consistent among the subgroups of stent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels <3.0 mm and lesions >15 mm length. © 2016 John Wiley & Sons Ltd.

  8. Evaluation of uranium transitions for isotopically-selective laser induced fluorescence with diode lasers (technical report for ST064)

    NASA Astrophysics Data System (ADS)

    Cannon, B. D.

    1993-10-01

    Isotopically-selective excitation of uranium atoms by diode lasers can be the basis for a portable instrument to perform uranium isotopic assays in the field. Such an instrument would improve the ability of on-site inspections to detect and deter nuclear proliferation. Published and unpublished spectroscopic data on atomic uranium were examined to identify candidate transitions for isotopically-selective laser excitation with diode lasers. Eleven candidate transitions were identified and evaluated for their potential usefulness for a portable uranium assay instrument. Eight of these transitions are suitable for laser induced fluorescence using different excitation and detection wavelengths, which will improve sensitivity and elemental selectivity. Data sheets on the 25 uranium transitions in the wavelength range 629 nm to 1,000 nm that originate in the ground or first excited states of neutral atomic uranium are included. Each data sheet provides the wavelength, upper and lower energy levels, angular momentum quantum numbers, U-235 isotope shift (relative to U-238, and high-resolution spectra of weapons-grade uranium (93% U-235 and 7% U-238).

  9. Litigation involving DES.

    PubMed

    Rheingold, P D

    1976-01-01

    Focus is on the diethylstilbestrol (DES) litigation which has resulted from the 1971 discovery that this synthetic estrogen can cause cancer in the daughters of women who used the drug during pregnancy in an effort to prevent threatened abortion. Possibly 100 suits are pending at this time in which DES daughters claim injuries. In most of these vaginal or cervical cancer has appeared -- with or without a hysterectomy having been performed. Several women died from cancer. The fact that the use of DES occurred many years ago is the legal hurdle most troublesome to lawyers. The average women coming to a lawyer's office today has a mother who used some form of DES, perhaps in 1955. Few drugstores have records today of the prescriptions which they filled 20 years ago. It has been estimated that over the 1950-1970 period more than 200 different companies manufactured or "tabletized" under their own name DES plus a variety of similar synthetic estrogens promoted for the prevention of threatened abortion. A further hurdle caused by the passage of time is that even the records of the physicians are frequently lost. A final problem created by the age of the cases is statute of limitations. If the actual manufacturer of the DES cannot be identified, this is generally the end of the lawyer's interest in the case. The chance of the plaintiff winning may be increased if the action against all the manufacturers is a class action. Most of the pending DES suits are against the manufacturer and not against the doctor. Thus far no DES case has been tried to completion. Several have been settled by the manufacturers on the eve of the trial, generally for less than the full sum that a cancer victim would expect to receive.

  10. Evaluation of the communication quality of free-space laser communication based on the power-in-the-bucket method.

    PubMed

    Yin, Xianghui; Wang, Rui; Wang, Shaoxin; Wang, Yukun; Jin, Chengbin; Cao, Zhaoliang; Xuan, Li

    2018-02-01

    Atmospheric turbulence seriously affects the quality of free-space laser communication. The Strehl ratio (SR) is used to evaluate the effect of atmospheric turbulence on the receiving energy of free-space laser communication systems. However, the SR method does not consider the area of the laser-receiving end face. In this study, the power-in-the-bucket (PIB) method is demonstrated to accurately evaluate the effect of turbulence on the receiving energy. A theoretical equation is first obtained to calculate PIB. Simulated and experimental validations are then performed to verify the effectiveness of the theoretical equation. This work may provide effective guidance for the design and evaluation of free-space laser communication systems.

  11. Médecine des voyages

    PubMed Central

    Aw, Brian; Boraston, Suni; Botten, David; Cherniwchan, Darin; Fazal, Hyder; Kelton, Timothy; Libman, Michael; Saldanha, Colin; Scappatura, Philip; Stowe, Brian

    2014-01-01

    Résumé Objectif Définir la pratique de la médecine des voyages, présenter les éléments fondamentaux d’une consultation complète préalable aux voyages à des voyageurs internationaux et aider à identifier les patients qu’il vaudrait mieux envoyer en consultation auprès de professionnels de la médecine des voyages. Sources des données Les lignes directrices et les recommandations sur la médecine des voyages et les maladies liées aux voyages publiées par les autorités sanitaires nationales et internationales ont fait l’objet d’un examen. Une recension des ouvrages connexes dans MEDLINE et EMBASE a aussi été effectuée. Message principal La médecine des voyages est une spécialité très dynamique qui se concentre sur les soins préventifs avant un voyage. Une évaluation exhaustive du risque pour chaque voyageur est essentielle pour mesurer avec exactitude les risques particuliers au voyageur, à son itinéraire et à sa destination et pour offrir des conseils sur les interventions les plus appropriées en gestion du risque afin de promouvoir la santé et prévenir les problèmes médicaux indésirables durant le voyage. Des vaccins peuvent aussi être nécessaires et doivent être personnalisés en fonction des antécédents d’immunisation du voyageur, de son itinéraire et du temps qu’il reste avant son départ. Conclusion La santé et la sécurité d’un voyageur dépendent du degré d’expertise du médecin qui offre le counseling préalable à son voyage et les vaccins, au besoin. On recommande à ceux qui donnent des conseils aux voyageurs d’être conscients de l’ampleur de cette responsabilité et de demander si possible une consultation auprès de professionnels de la médecine des voyages pour tous les voyageurs à risque élevé.

  12. Laser cleaning of works of art: evaluation of the thermal stress induced by Er:YAG laser

    NASA Astrophysics Data System (ADS)

    De Cruz, A.; Andreotti, A.; Ceccarini, A.; Colombini, M. P.

    2014-06-01

    The Er:YAG laser has proven particularly efficient in cleaning procedures of works of art. The removal of the superficial deposits is achieved through melting, thermal decomposition and evaporation. However, the energy absorbed by vibrational modes is dissipated as heat, increasing the temperature of the surface coating that could cause damage on the object. The aim of this study was to evaluate the temperature increase induced by a Er:YAG MonaLaser (LLC., Orlando, FL, USA). To that purpose, we designed a dedicated device to perform the tests in an inert atmosphere or with a wetting agent, to measure the radiant energy per laser pulse. Tests were carried out both on graphite, which absorbs IR radiation and showed a very intense flash emission, and on different kind of samples representative of materials with different levels of conductivity and thermal diffusivity. Results obtained showed that the temperature increase in the irradiated surface depends on the substrate but never causes the damage of the organic and inorganic material. The use of a solvent as wetting agent has been also tested.

  13. Determination des Parametres Atmospheriques des Etoiles Naines Blanches de Type DB

    NASA Astrophysics Data System (ADS)

    Beauchamp, Alain

    1995-01-01

    Les etoiles naines blanches dont les spectres visibles sont domines par des raies fortes d'helium neutre sont subdivisees en trois classes, DB (raies d'helium neutre seulement), DBA (raies d'helium neutre et d'hydrogene) et DBZ (raies d'helium neutre et d'elements lourds). Nous analysons trois echantillons de spectres observes de ces types de naines blanches. Les echantillons consistent, respectivement, de 48 spectres dans le domaine du visible (3700-5100 A). 24 dans l'ultraviolet (1200-3100 A) et quatre dans la partie rouge du visible (5100-6900) A). Parmi les objets de l'echantillon visible, nous identifions quatre nouvelles DBA, ainsi que deux nouvelles DBZ, auparavant classees DB. L'analyse nous permet de determiner spectroscopiquement les parametres atmospheriques, soit la temperature effective, la gravite de surface, ainsi que l'abondance relative de l'hydrogene, N(H)/N(He), dans le cas des DBA. Pour les objets plus chauds que ~15,000 K, la gravite de surface determinee est fiable, et nous obtenons les masses stellaires avec une relation masse -rayon theorique. Les exigences propres a l'analyse de ces objets ont requis d'importantes ameliorations dans la modelisation de leurs atmospheres et distributions de flux de radiation emis par ces derniers. Nous avons inclus dans les modeles d'atmospheres, pour la premiere fois a notre connaissance, les effets dus a la molecule He_sp{2 }{+}, ainsi que l'equation d'etat de Hummer et Mihalas (1988), qui tient compte des perturbations entre particules dans le calcul des populations des differents niveaux atomiques. Nous traitons la convection dans le cadre de la theorie de la longueur de melange. Trois grilles de modeles d'atmospheres a l'ETL (equilibre thermodynamique local) ont ete produites, pour un ensemble de temperatures effectives, gravites de surface et abondances d'hydrogene couvrant les proprietes des etoiles de nos echantillons; elles sont caracterisees par differentes parametrisations appelees, respectivement

  14. Skin perfusion evaluation between laser speckle contrast imaging and laser Doppler flowmetry

    NASA Astrophysics Data System (ADS)

    Humeau-Heurtier, Anne; Mahe, Guillaume; Durand, Sylvain; Abraham, Pierre

    2013-03-01

    In the biomedical field, laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) are two optical techniques aiming at monitoring - non-invasively - the microvascular blood perfusion. LDF has been used for nearly 40 years whereas LSCI is a recent technique that overcomes some drawbacks of LDF. Both LDF and LSCI give perfusion assessments in arbitrary units. However, the possible relationship existing between perfusions given by LDF and by LSCI over large blood flow values has not been completely studied yet. We therefore herein evaluate the relationship between the LDF and LSCI perfusion values across a broad range of skin blood flows. For this purpose, LDF and LSCI data were acquired simultaneously on the forearm of 12 healthy subjects, at rest, during different durations of vascular occlusion and during reactive hyperemia. For the range of skin blood flows studied, the power function fits the data better than the linear function: powers for individual subjects go from 1.2 to 1.7 and the power is close to 1.3 when all the subjects are studied together. We thus suggest distinguishing perfusion values given by the two optical systems.

  15. Revision of laser-induced damage threshold evaluation from damage probability data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bataviciute, Gintare; Grigas, Povilas; Smalakys, Linas

    2013-04-15

    In this study, the applicability of commonly used Damage Frequency Method (DFM) is addressed in the context of Laser-Induced Damage Threshold (LIDT) testing with pulsed lasers. A simplified computer model representing the statistical interaction between laser irradiation and randomly distributed damage precursors is applied for Monte Carlo experiments. The reproducibility of LIDT predicted from DFM is examined under both idealized and realistic laser irradiation conditions by performing numerical 1-on-1 tests. A widely accepted linear fitting resulted in systematic errors when estimating LIDT and its error bars. For the same purpose, a Bayesian approach was proposed. A novel concept of parametricmore » regression based on varying kernel and maximum likelihood fitting technique is introduced and studied. Such approach exhibited clear advantages over conventional linear fitting and led to more reproducible LIDT evaluation. Furthermore, LIDT error bars are obtained as a natural outcome of parametric fitting which exhibit realistic values. The proposed technique has been validated on two conventionally polished fused silica samples (355 nm, 5.7 ns).« less

  16. Evaluation of automated serum des-gamma-carboxyprothrombin (DCP) assays for detecting hepatocellular carcinoma.

    PubMed

    Choi, Jonghyeon; Park, Yongjung; Kim, Jeong-Ho; Kim, Hyon-Suk

    2011-12-01

    We evaluated two new autoanalyzers, μTAS and Lumipulse for des-γ-carboxyprothrombin (DCP) assay. Analytical performance was evaluated, and the upper reference limit of the 97.5th percentile for DCP was re-established using sera from 140 healthy individuals. DCP levels were determined by the two autoanalyzers and EIA in a total of 239 sera from HCC patients (n=120) and those without HCC (n=119). Total imprecision of the two automated assays was <5% CV. Analytical measurement ranges (AMRs) were verified to be linear. The new reference limits were 29.5 mAU/mL for μTAS and 35.0 mAU/mL for Lumipulse. There were proportional and constant biases between the results from the autoanalyzers and those from EIA. The two newly developed DCP assays showed high analytical performance, but re-establishment of reference limits would be necessary. The new analyzers could be useful for clinical laboratories because of convenience of operation and wide AMRs. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Comparative Evaluation of Effects of Laser Modalities on Shear Bond Strengths of Veneering Porcelains to Laser Sintered Substructures: An In Vitro Study.

    PubMed

    Gorler, Oguzhan; Saygin, Aysegul Goze

    2017-06-01

    Laser modalities and direct metal laser sintering (DMLS) have a potential to enhance micromechanical bonding between dental super- and infrastructures. However, the effect of different manufacturing methods on the metal-ceramic bond strength needs further evaluation. We investigated the effect of surface treatment with Er:YAG, Nd:YAG, and Ho:YAG lasers on the shear bond strength (SBS) of high-fusion dental porcelains (Vita and G-Ceram) to infrastructures prepared with DMLS in vitro settings. Study specimens (n = 128) were randomly divided into study subsets (n = 8), considering treatment types applied on the surface of infrastructures, including sandblasting and selected laser modalities; infrastructure types as direct laser sintered (DLS) and Ni-Cr based; and superstructure porcelains as Vita and G-Ceram. The SBS test was performed to assess the effectiveness of surface modifications that were also examined with a stereo microscope. Considering laser procedure types, the highest SBS values were obtained by Er:YAG laser, followed by, with a decreasing efficiency, Ho:YAG laser and sandblasting procedures, and Nd:YAG laser procedure (p < 0.05). Nd:YAG laser decreases the bonding of Vita and G-Ceram in all the infrastructures compared with sandblasting. Considering porcelains, the highest SBS values were obtained by Vita (p < 0.05). Considering infrastructures, the highest SBS values were obtained by DMLS procedure (p < 0.05). The laser procedures caused surface irregularities as revealed by the stereo microscopic examination. In current experimental settings, Er:YAG laser applied to DLS infrastructure veneered with Vita porcelain increases bonding strength more distinctly, and Nd:YAG laser applied to Ni-Cr-based infrastructure veneered with G-Ceram porcelain alters bonding strength unfavorably.

  18. Etude numerique et experimentale de la reponse vibro-acoustique des structures raidies a des excitations aeriennes et solidiennes

    NASA Astrophysics Data System (ADS)

    Mejdi, Abderrazak

    Les fuselages des avions sont generalement en aluminium ou en composite renforces par des raidisseurs longitudinaux (lisses) et transversaux (cadres). Les raidisseurs peuvent etre metalliques ou en composite. Durant leurs differentes phases de vol, les structures d'avions sont soumises a des excitations aeriennes (couche limite turbulente : TBL, champs diffus : DAF) sur la peau exterieure dont l'energie acoustique produite se transmet a l'interieur de la cabine. Les moteurs, montes sur la structure, produisent une excitation solidienne significative. Ce projet a pour objectifs de developper et de mettre en place des strategies de modelisations des fuselages d'avions soumises a des excitations aeriennes et solidiennes. Tous d'abord, une mise a jour des modeles existants de la TBL apparait dans le deuxieme chapitre afin de mieux les classer. Les proprietes de la reponse vibro-acoustique des structures planes finies et infinies sont analysees. Dans le troisieme chapitre, les hypotheses sur lesquelles sont bases les modeles existants concernant les structures metalliques orthogonalement raidies soumises a des excitations mecaniques, DAF et TBL sont reexamines en premier lieu. Ensuite, une modelisation fine et fiable de ces structures est developpee. Le modele est valide numeriquement a l'aide des methodes des elements finis (FEM) et de frontiere (BEM). Des tests de validations experimentales sont realises sur des panneaux d'avions fournis par des societes aeronautiques. Au quatrieme chapitre, une extension vers les structures composites renforcees par des raidisseurs aussi en composites et de formes complexes est etablie. Un modele analytique simple est egalement implemente et valide numeriquement. Au cinquieme chapitre, la modelisation des structures raidies periodiques en composites est beaucoup plus raffinee par la prise en compte des effets de couplage des deplacements planes et transversaux. L'effet de taille des structures finies periodiques est egalement pris en

  19. Electronic properties of solids excited with intermediate laser power densities

    NASA Astrophysics Data System (ADS)

    Sirotti, Fausto; Tempo Beamline Team

    Intermediate laser power density up to about 100 GW/cm2 is below the surface damage threshold is currently used to induce modification in the physical properties on short time scales. The absorption of a short laser pulse induces non-equilibrium electronic distributions followed by lattice-mediated equilibrium taking place only in the picosecond range. The role of the hot electrons is particularly important in several domains as for example fast magnetization and demagnetization processes, laser induced phase transitions, charge density waves. Angular resolved photoelectron spectroscopy measuring directly energy and momentum of electrons is the most adapted tool to study the electronic excitations at short time scales during and after fast laser excitations. The main technical problem is the space charge created by the pumping laser pulse. I will present angular resolved multiphoton photoemission results obtained with 800 nm laser pulses showing how space charge electrons emitted during fast demagnetization processes can be measured. Unable enter Affiliation: CNRS-SOLEIL Synchrotron L'Orme des Merisiers , Saint Aubin 91192 Gif sur Yvette France.

  20. Multimodal evaluation of ultra-short laser pulses treatment for skin burn injuries.

    PubMed

    Santos, Moises Oliveira Dos; Latrive, Anne; De Castro, Pedro Arthur Augusto; De Rossi, Wagner; Zorn, Telma Maria Tenorio; Samad, Ricardo Elgul; Freitas, Anderson Zanardi; Cesar, Carlos Lenz; Junior, Nilson Dias Vieira; Zezell, Denise Maria

    2017-03-01

    Thousands of people die every year from burn injuries. The aim of this study is to evaluate the feasibility of high intensity femtosecond lasers as an auxiliary treatment of skin burns. We used an in vivo animal model and monitored the healing process using 4 different imaging modalities: histology, Optical Coherence Tomography (OCT), Second Harmonic Generation (SHG), and Fourier Transform Infrared (FTIR) spectroscopy. 3 dorsal areas of 20 anesthetized Wistar rats were burned by water vapor exposure and subsequently treated either by classical surgical debridement, by laser ablation, or left without treatment. Skin burn tissues were non-invasively characterized by OCT images and biopsied for further histopathology analysis, SHG imaging and FTIR spectroscopy at 3, 5, 7 and 14 days after burn. The laser protocol was found as efficient as the classical treatment for promoting the healing process. The study concludes to the validation of femtosecond ultra-short pulses laser treatment for skinburns, with the advantage of minimizing operatory trauma.

  1. Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography.

    PubMed

    Kim, Youngseop; Choi, Eun Seo; Kwak, Wooseop; Shin, Yongjin; Jung, Woonggyu; Ahn, Yeh-Chan; Chen, Zhongping

    2008-06-01

    We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristics of the pit are analyzed and compared. From the results, we could verify the feasibility and the potential of the application of OCT to the monitoring of the laser-processing performance.

  2. Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography

    PubMed Central

    Kim, Youngseop; Choi, Eun Seo; Kwak, Wooseop; Shin, Yongjin; Jung, Woonggyu; Ahn, Yeh-Chan; Chen, Zhongping

    2014-01-01

    We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristics of the pit are analyzed and compared. From the results, we could verify the feasibility and the potential of the application of OCT to the monitoring of the laser-processing performance. PMID:24932051

  3. Evaluation of the efficacy of low-level laser in improving the symptoms of burning mouth syndrome.

    PubMed

    Arbabi-Kalati, Fateme; Bakhshani, Nour-Mohammad; Rasti, Maryam

    2015-10-01

    Burning mouth syndrome (BMS) is common conditions that affects menopause women, patients suffer from sever burning sensation. Up to now there is no definitive treatment for this disease. Present study was undertaken to evaluate the efficacy of low-level laser (LLL) in improving the symptoms of burning mouth syndrome. Twenty patients with BMS were enrolled in this study; they were divided in two groups randomly. In the laser group, in each patient, 10 areas on the oral mucosa were selected and underwent LLL irradiation at a wavelength of 630 nm, and a power of 30 mW for 10 seconds twice a week for 4 weeks. In the placebo group, silent/off laser therapy was carried out during the same period in the same areas. Burning sensation and quality of life were evaluated. Burning sensation severity and quality of life in the two groups after intervention were different significant statistically, (p= 0.004, p= 0.01 respectively) .Patients in laser group had better results. It can be concluded that low level laser might decrease the intensity of burning mouth syndrome. Pain, low-level laser, burning mouth syndrome, oral mucosa.

  4. Evaluation of the efficacy of low-level laser in improving the symptoms of burning mouth syndrome

    PubMed Central

    Bakhshani, Nour-Mohammad; Rasti, Maryam

    2015-01-01

    Background Burning mouth syndrome (BMS) is common conditions that affects menopause women, patients suffer from sever burning sensation. Up to now there is no definitive treatment for this disease. Present study was undertaken to evaluate the efficacy of low-level laser (LLL) in improving the symptoms of burning mouth syndrome. Material and Methods Twenty patients with BMS were enrolled in this study; they were divided in two groups randomly. In the laser group, in each patient, 10 areas on the oral mucosa were selected and underwent LLL irradiation at a wavelength of 630 nm, and a power of 30 mW for 10 seconds twice a week for 4 weeks. In the placebo group, silent/off laser therapy was carried out during the same period in the same areas. Burning sensation and quality of life were evaluated. Results Burning sensation severity and quality of life in the two groups after intervention were different significant statistically, (p= 0.004, p= 0.01 respectively) .Patients in laser group had better results. Conclusions It can be concluded that low level laser might decrease the intensity of burning mouth syndrome. Key words:Pain, low-level laser, burning mouth syndrome, oral mucosa. PMID:26535101

  5. Dynamic laser speckle for non-destructive quality evaluation of bread

    NASA Astrophysics Data System (ADS)

    Stoykova, E.; Ivanov, B.; Shopova, M.; Lyubenova, T.; Panchev, I.; Sainov, V.

    2010-10-01

    Coherent illumination of a diffuse object yields a randomly varying interference pattern, which changes over time at any modification of the object. This phenomenon can be used for detection and visualization of physical or biological activity in various objects (e.g. fruits, seeds, coatings) through statistical description of laser speckle dynamics. The present report aims at non-destructive full-field evaluation of bread by spatial-temporal characterization of laser speckle. The main purpose of the conducted experiments was to prove the ability of the dynamic speckle method to indicate activity within the studied bread samples. In the set-up for acquisition and storage of dynamic speckle patterns an expanded beam from a DPSS laser (532 nm and 100mW) illuminated the sample through a ground glass diffuser. A CCD camera, adjusted to focus the sample, recorded regularly a sequence of images (8 bits and 780 x 582 squared pixels, sized 8.1 × 8.1 μm) at sampling frequency 0.25 Hz. A temporal structure function was calculated to evaluate activity of the bread samples in time using the full images in the sequence. In total, 7 samples of two types of bread were monitored during a chemical and physical process of bread's staling. Segmentation of images into matrixes of isometric fragments was also utilized. The results proved the potential of dynamic speckle as effective means for monitoring the process of bread staling and ability of this approach to differentiate between different types of bread.

  6. Etude de la Generation des Ultrasons Par Laser dans un Materiau Composite

    NASA Astrophysics Data System (ADS)

    Dubois, Marc

    Laser generation of ultrasound is not a new subject. Many authors have proposed mathematical models of the thermoelastic process of generation of acoustic waves. However, none of those models, up to now, could take simultaneously the effects of the thermal conduction, the optical penetration, the anisotropy of the material and any time and surface profiles of the laser excitation into account. The model presented in this work takes all these parameters into consideration in the case of an infinite orthotropic plate. The mathematical approach used allows to obtain an analytical solution of the mechanical displacement field in the Laplace and two-dimensional (2-D) Fourier spaces. Numerical inverse Laplace and 2-D Fourier transformations bring the mechanical displacement field back into the normal spaces. The use of direct numerical transformations enables to consider almost any time and spatial distributions of the generation laser beam. The acoustic displacements calculated by this model have been compared to experimental displacements measured with a wide band optical detection system. The features of this system allow the quantitative measurement of the parallel and normal displacements to the surface of the sample. Hence, the calculated normal and parallel displacements have been compared to those experimentally measured at various locations on aluminum, glass and polymer samples. In all cases, the agreement between the calculated and experimentally measured displacements was good. The semi-analytical model having proved its validity, it has been used, in addition to a completely analytical one-dimensional model, to study the effects of the optical penetration and the laser pulse duration on the longitudinal acoustic wave generated. This study has established that a short enough laser pulse and a large irradiation with regard to the sample thickness allows to determine quantitatively, from the full width at half maximum of the acoustic pulse, the optical

  7. Effectiveness evaluation of double-layered satellite network with laser and microwave hybrid links based on fuzzy analytic hierarchy process

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Rao, Qiaomeng

    2018-01-01

    In order to solve the problem of high speed, large capacity and limited spectrum resources of satellite communication network, a double-layered satellite network with global seamless coverage based on laser and microwave hybrid links is proposed in this paper. By analyzing the characteristics of the double-layered satellite network with laser and microwave hybrid links, an effectiveness evaluation index system for the network is established. And then, the fuzzy analytic hierarchy process, which combines the analytic hierarchy process and the fuzzy comprehensive evaluation theory, is used to evaluate the effectiveness of the double-layered satellite network with laser and microwave hybrid links. Furthermore, the evaluation result of the proposed hybrid link network is obtained by simulation. The effectiveness evaluation process of the proposed double-layered satellite network with laser and microwave hybrid links can help to optimize the design of hybrid link double-layered satellite network and improve the operating efficiency of the satellite system.

  8. Evaluation of Analysis Conditions for Laser-Pulsed Atom Probe Tomography: Example of Cemented Tungsten Carbide.

    PubMed

    Peng, Zirong; Choi, Pyuck-Pa; Gault, Baptiste; Raabe, Dierk

    2017-04-01

    Cemented tungsten carbide has been analyzed using laser-pulsed atom probe tomography (APT). The influence of experimental parameters, including laser pulse energy, pulse repetition rate, and specimen base temperature, on the acquired data were evaluated from different aspects, such as mass spectrum, chemical composition, noise-to-signal ratio, and multiple events. Within all the applied analysis conditions, only 1 MHz pulse repetition rate led to a strong detector saturation effect, resulting in a largely biased chemical composition. A comparative study of the laser energy settings showed that an ~12 times higher energy was required for the less focused green laser of the LEAPTM 3000X HR system to achieve a similar evaporation field as the finer spot ultraviolet laser of the LEAPTM 5000 XS system.

  9. Quantification des besoins en intrants antipaludiques: contribution à l'actualisation des hypothèses pour la quantification des intrants de prise en charge des cas de paludisme grave en République Démocratique du Congo

    PubMed Central

    Likwela, Joris Losimba; Otokoye, John Otshudiema

    2015-01-01

    Les formes graves de paludisme à Plasmodium falciparum sont une cause majeure de décès des enfants de moins de 5 ans en Afrique Sub-saharienne. Un traitement rapide dépend de la disponibilité de médicaments appropriés au niveau des points de prestation de service. La fréquence des ruptures de stock des commodités antipaludiques, en particuliers celles utilisées pour le paludisme grave, avait nécessité une mise à jour des hypothèses de quantification. Les données issues de la collecte de routine du PNLP de 2007 à 2012 ont été comparées à celles rapportés par d'autres pays africains et utilisées pour orienter les discussions au cours d'un atelier organisé par le PNLP et ses partenaires techniques et financiers afin de dégager un consensus national. La proportion des cas de paludisme rapportés comme grave en RDC est resté autour d'une médiane de 7% avec un domaine de variation de 6 à 9%. Hormis la proportion rapportée au Kenya (2%), les pays africains ont rapporté une proportion de cas grave variant entre 5 et 7%. Il apparaît que la proportion de 1% précédemment utilisée pour la quantification en RDC a été sous-estimée dans le contexte de la gestion des cas graves sur terrain. Un consensus s'est dégagé autour de la proportion de 5% étant entendu que des efforts de renforcement des capacités seraient déployés afin d'améliorer le diagnostic au niveau des points de prestation des services. PMID:26213595

  10. Consistency analysis on laser signal in laser guided weapon simulation

    NASA Astrophysics Data System (ADS)

    Yin, Ruiguang; Zhang, Wenpan; Guo, Hao; Gan, Lin

    2015-10-01

    The hardware-in-the-loop simulation is widely used in laser semi-active guidance weapon experiments, the authenticity of the laser guidance signal is the key problem of reliability. In order to evaluate the consistency of the laser guidance signal, this paper analyzes the angle of sight, laser energy density, laser spot size, atmospheric back scattering, sun radiation and SNR by comparing the different working state between actual condition and hardware-in-the-loop simulation. Based on measured data, mathematical simulation and optical simulation result, laser guidance signal effects on laser seeker are determined. By using Monte Carlo method, the laser guided weapon trajectory and impact point distribution are obtained, the influence of the systematic error are analyzed. In conclusion it is pointed out that the difference between simulation system and actual system has little influence in normal guidance, has great effect on laser jamming. The research is helpful to design and evaluation of laser guided weapon simulation.

  11. Evaluation of low-level laser therapy in the treatment of masticatory muscles spasticity in children with cerebral palsy

    NASA Astrophysics Data System (ADS)

    Santos, Maria Teresa Botti Rodrigues; Diniz, Michele Baffi; Gouw-Soares, Sheila Cynthia; Lopes-Martins, Rodrigo Alvaro Brandão; Frigo, Lucio; Baeder, Fernando Martins

    2016-02-01

    Spasticity is a motor disorder frequently present in individuals with cerebral palsy (CP). This study aimed to evaluate the effect of low-level laser therapy (LLLT) on the spasticity of the masseter and anterior temporal muscle fibers in children with CP over three weeks of intermittent laser exposures. The bite force (BF) of the masticatory muscles and the amplitude of mouth opening were evaluated before and after laser irradiation in 30 children with CP. Both sides of the masseter and temporalis muscles were irradiated with low-intensity diode laser pulses of 808-nm wavelength six times over three consecutive weeks. During the subsequent three weeks of postlaser exposures, although no laser treatment was applied, the evaluation parameters were measured and recorded. A significant improvement in the amplitude of mouth opening and a decrease in the BF were observed in the weeks following LLLT (P<0.05). However, by the sixth week post-LLLT, the BF and the amplitude of mouth opening reverted to values equivalent to those obtained before the first application of LLLT. Our investigation revealed low-level energy exposures from a 808-nm diode laser to be an effective short-term therapeutic tool. This method increased the amplitude of mouth opening and decreased the muscle tonus of children with spastic CP over a time course of three weeks of intermittent laser applications.

  12. Caracterisation des proprietes acoustiques des materiaux poreux a cellules ouvertes et a matrice rigide ou souple

    NASA Astrophysics Data System (ADS)

    Salissou, Yacoubou

    L'objectif global vise par les travaux de cette these est d'ameliorer la caracterisation des proprietes macroscopiques des materiaux poreux a structure rigide ou souple par des approches inverses et indirectes basees sur des mesures acoustiques faites en tube d'impedance. La precision des approches inverses et indirectes utilisees aujourd'hui est principalement limitee par la qualite des mesures acoustiques obtenues en tube d'impedance. En consequence, cette these se penche sur quatre problemes qui aideront a l'atteinte de l'objectif global precite. Le premier probleme porte sur une caracterisation precise de la porosite ouverte des materiaux poreux. Cette propriete en est une de passage permettant de lier la mesure des proprietes dynamiques acoustiques d'un materiau poreux aux proprietes effectives de sa phase fluide decrite par les modeles semi-phenomenologiques. Le deuxieme probleme traite de l'hypothese de symetrie des materiaux poreux selon leur epaisseur ou un index et un critere sont proposes pour quantifier l'asymetrie d'un materiau. Cette hypothese est souvent source d'imprecision des methodes de caracterisation inverses et indirectes en tube d'impedance. Le critere d'asymetrie propose permet ainsi de s'assurer de l'applicabilite et de la precision de ces methodes pour un materiau donne. Le troisieme probleme vise a mieux comprendre le probleme de transmission sonore en tube d'impedance en presentant pour la premiere fois un developpement exact du probleme par decomposition d'ondes. Ce developpement permet d'etablir clairement les limites des nombreuses methodes existantes basees sur des tubes de transmission a 2, 3 ou 4 microphones. La meilleure comprehension de ce probleme de transmission est importante puisque c'est par ce type de mesures que des methodes permettent d'extraire successivement la matrice de transfert d'un materiau poreux et ses proprietes dynamiques intrinseques comme son impedance caracteristique et son nombre d'onde complexe. Enfin, le

  13. Caracterisation des revetements par projection thermique a haute vitesse obtenus a partir de differentes poudres de wc-10co-4cr pour des applications en aeronautique =

    NASA Astrophysics Data System (ADS)

    Quintero Malpica, Alfonso

    Les revetements par projection thermique HVOF (High Velocity Oxy-Fuel) sont communement utilises dans l'industrie aeronautique, notamment au sein du partenaire industriel du projet (Tecnickrome Aeronautique Inc), comme des remplacants pour les revetements produits par l'electrodeposition du chrome dur due aux problemes environnementaux. Ce projet avait pour but de trouver une poudre alternative a celle qui est actuellement utilisee pour la production des revetements de type WC-10Co-4Cr obtenus avec la technologie de projection thermique a haute vitesse HVOF et en utilisant le systeme de projection HVOF-JET KOTERTM III. Dans un premier temps, cinq poudres incluant celle de reference, ayant des distributions granulometriques differentes, ont ete projetees dans le but d'identifier quelles poudres pouvaient etre utilisees avec le systeme de projection HVOF-JET KOTERTM III en gardant des parametres similaires (debit d'hydrogene, debit d'oxygene, debit de poudre et distance de projection) que pour la poudre de reference. Les revetements obtenus a partir des poudres etudiees ont ete evalues selon les criteres d'acceptation des revetements sollicites par les principaux manufacturiers des trains d'atterrissage. Les tests ont porte sur l'epaisseur, l'adhesion, la microstructure, la microdurete, les contraintes residuelles et la rugosite. A partir des resultats obtenus, seulement deux poudres ont rencontre toutes les proprietes demandees par les specifications aeronautiques. L'influence de la variation de la distance de projection sur la qualite des revetements a ete etudiee. Cinq distances (100, 125, 150, 175 et 200 mm) ont ete choisies pour faire la projection des deux poudres selectionnees. Les revetements obtenus ont montre de proprietes des revetements similaires (epaisseur, adhesion, microstructure, microdurete, contraintes residuelles et rugosite). Il a ete trouve que la distance de projection est un parametre indirect du systeme de projection HVOF-JET KOTERTM III et

  14. [Evaluation of free radical quantity in the anterior chamber following femtosecond laser-assisted capsulotomy].

    PubMed

    Tóth, Gábor; Sándor, Gábor László; Kleiner, Dénes; Szentmáry, Nóra; Kiss, Huba J; Blázovics, Anna; Nagy, Zoltán Zsolt

    2016-11-01

    Femtosecond laser is a revolutionary, innovative treatment method used in cataract surgery. To evaluate free radical quantity in the anterior chamber of the eye, during femtosecond laser assisted capsulotomy, in a porcine eye model. Seventy fresh porcine eyes were collected within 2 hours post mortem, were transported at 4 ºC and treated within 7 hours. Thirty-five eyes were used as control and 35 as femtosecond laser assisted capsulotomy group. A simple luminol-dependent chemiluminescence method was used to measure the total scavenger capacity in the aqueous humour, as an indicator of free radical production. The emitted photons were expressed in relative light unit %. The relative light unit % was lower in the control group (median 1%, interquartile range [0.4-3%]) than in the femtosecond laser assisted capsulotomy group (median 4.4%, interquartile range [1.5%-21%]) (p = 0.01). Femtosecond laser assisted capsulotomy decreases the antioxidant defense of the anterior chamber, which refers to a significant free radical production during femtosecond laser assisted capsulotomy. Orv. Hetil., 2016, 157(47), 1880-1883.

  15. Evaluation of Laser Braze-welded Dissimilar Al-Cu Joints

    NASA Astrophysics Data System (ADS)

    Schmalen, Pascal; Plapper, Peter

    The thermal joining of Aluminum and Copper is a promising technology towards automotive battery manufacturing. The dissimilar metals Al-Cu are difficult to weld due to their different physicochemical characteristics and the formation of intermetallic compounds (IMC), which have reduced mechanical and electric properties. There is a critical thickness of the IMCs where the favored mechanical properties of the base material can be preserved. The laser braze welding principle uses a position and power oscillated laser-beam to reduce the energy input and the intermixture of both materials and therefore achieves minimized IMCs thickness. The evaluation of the weld seam is important to improve the joint performance and enhance the welding process. This paper is focused on the characterization and quantification of the IMCs. Mechanical, electrical and metallurgical methods are presented and performed on Al1050 and SF-Cu joints and precise weld criteria are developed.

  16. Evaluation of a fluorescence feedback system for guidance of laser angioplasty.

    PubMed

    Deckelbaum, L I; Desai, S P; Kim, C; Scott, J J

    1995-01-01

    Laser-induced fluorescence spectroscopy (LIFS) may be capable of guiding laser angioplasty by discriminating normal and atherosclerotic artery and by determining catheter-tissue environment. Previous optical multichannel analyzer based LIFS systems have been expensive and cumbersome. To simplify LIFS, a system based on photomultiplier tubes was developed and evaluated. Tissue fluorescence was induced by a helium cadmium laser (wavelength = 325 nm, power = 0.2-0.5 mW), collected by clinical multifiber laser angioplasty catheters and directed through one of two filters (10 nm bandpass, 380 nm or 440 nm peak transmission) to a photomultiplier tube. An LIFS ratio was defined as the relative intensity at 380:440 nm after calibration with an elastin fluorescence spectrum; 157 coronary artery cadaveric specimens were evaluated spectroscopically and histologically. To evaluate the utility of LIFS to optimize catheter position by determining catheter-tissue contact, by determining saline dilution of blood, and by orienting eccentric multifiber catheters a new variable, the total fluorescence intensity (TFI) was defined as the sum of arterial fluorescence intensities at 380 nm and 440 nm. TFI was recorded in vitro through multifiber catheters from 20 arterial specimens in vitro in blood and evaluated as a function of the catheter-to-tissue distance (d) over a range from 0 to 400 mu. Defining normal specimens as those with an intimal thickness < or = 200 mu, and atherosclerotic as those with an intimal thickness > 200 mu, 47/50 (94%) normal and 85/107 (79%) atherosclerotic specimens were correctly classified using a threshold LIFS ratio of 2.0. Mean (+/- SE) normal ratio was 1.76 +/- 0.02 and mean atherosclerotic ratio was 2.78 +/- 0.08 (P < or = 0.01). The classification accuracy of atherosclerotic specimens increased with intimal thickness so that 95% of atherosclerotic specimens (69/73) with intimal thickness > or = 400 mu were correctly classified. TFI was capable of

  17. Fractional versus ablative erbium:yttrium-aluminum-garnet laser resurfacing for facial rejuvenation: an objective evaluation.

    PubMed

    El-Domyati, Moetaz; Abd-El-Raheem, Talal; Abdel-Wahab, Hossam; Medhat, Walid; Hosam, Wael; El-Fakahany, Hasan; Al Anwer, Mustafa

    2013-01-01

    Laser is one of the main tools for skin resurfacing. Erbium:yttrium-aluminum-garnet (Er:YAG) was the second ablative laser, after carbon dioxide, emitting wavelength of 2940 nm. Fractional laser resurfacing has been developed to overcome the drawbacks of ablative lasers. We aimed to objectively evaluate the histopathological and immunohistochemical effects of Er:YAG 2940-nm laser for facial rejuvenation (multiple sessions of fractional vs single session of ablative Er:YAG laser). Facial resurfacing with single-session ablative Er:YAG laser was performed on 6 volunteers. Another 6 were resurfaced using fractional Er:YAG laser (4 sessions). Histopathological (hematoxylin-eosin, orcein, Masson trichrome, and picrosirius red stains) and immunohistochemical assessment for skin biopsy specimens were done before laser resurfacing and after 1 and 6 months. Histometry for epidermal thickness and quantitative assessment for neocollagen formation; collagen I, III, and VII; elastin; and tropoelastin were done for all skin biopsy specimens. Both lasers resulted in increased epidermal thickness. Dermal collagen showed increased neocollagen formation with increased concentration of collagen types I, III, and VII. Dermal elastic tissue studies revealed decreased elastin whereas tropoelastin concentration increased after laser resurfacing. Neither laser showed significant difference between their effects clinically and on dermal collagen. Changes in epidermal thickness, elastin, and tropoelastin were significantly more marked after ablative laser. The small number of patients is a limitation, yet the results show significant improvement. Multiple sessions of fractional laser have comparable effects to a single session of ablative Er:YAG laser on dermal collagen but ablative laser has more effect on elastic tissue and epidermis. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Numerical simulation of evaluation of surface breaking cracks by array-lasers generated narrow-band SAW

    NASA Astrophysics Data System (ADS)

    Dong, Li-Ming; Ni, Chen-Yin; Shen, Zhong-Hua; Ni, Xiao-Wu

    2011-09-01

    Most of the factors limiting the extensive application of laser-based ultrasonic for nondestructive evaluation of surface breaking crack are its poor sensitivity, low efficiency relative to conventional contact ultrasonic methods and limit on the dimension of the cracks. For this reason, a new technique that multiplepulse narrow-band ultrasound generated by laser arrays has been proposed. It is found that crack detection dependent on spectrum of narrow-band ultrasound generated by laser arrays can be operated with low amplitude requirements. In this paper, the narrow-band ultrasound generated by pulse laser arrays interacting with surface breaking cracks has been simulated in detail by the finite element method (FEM) according to the thermoelastic theory. The pulsed array lasers were assumed to be transient heat source, and the surface acoustic wave (SAW) which propagating on the top of the plate was computed based on thermoelastic theory. Then the frequency spectrums of both reflected waves by crack and transmission ones through crack were compared with the direct waves. Results demonstrate that multiple-frequency components of the narrow-band ultrasound were varied with change of the depth of surface breaking cracks significantly, which provides the possibility for precise evaluation of surface breaking cracks.

  19. Spectroscopie Raman et Rayleigh stimulée des mélasses optiques unidimensionnelles (partie I)

    NASA Astrophysics Data System (ADS)

    Courtois, Jean-Yves

    stimulated Raman lines are homogeneously broadened, and that a stimulated Rayleigh structure appears on the spectra because of the probe-induced time modulation of the cooling force, which induces a modulation of the atomic momentum distribution. In the latter situation, the Raman structures are inhomogeneously broadened, and a recoil-induced resonance is predicted in the center of the spectrum. Its shape corresponds to the derivative of a Gaussian curve and its width is directly proportional to the Doppler width of the molasses. Finally, Section 6 presents a short review about the recent developments in the field of nonlinear spectroscopy of optical molasses. Cet article s'inscrit dans le double contexte de la spectroscopie non linéaire des milieux atomiques et de la physique du refroidissement d'atomes neutres par laser. Il présente une étude détaillée des spectres de transmission d'une onde sonde interagissant avec une mélasse optique unidimensionnelle. Plus précisément, nous montrons que dans chacun des deux cas modèles des mélasses “linperp lin” et “σ^+-σ^-” (ainsi dénommées par référence à la configuration de polarisation des deux faisceaux lasers à l'origine du mécanisme de refroidissement), les spectres pompes-sonde présentent des structures résonnantes pouvant s'interpréter en termes de diffusion Raman ou Rayleigh stimulée, et apportant un grand nombre d'informations sur les propriétés physiques des mélasses optiques. Cet article s'articule autour de deux grandes parties. Destinée à faire ultérieurement ressortir la spécificité des processus de diffusion stimulée se produisant dans les mélasses optiques, la première est consacrée à une présentation générale des processus Raman et Rayleigh stimulés se produisant dans les milieux atomiques et moléculaires conventionnels. L'effet Raman stimulé, lié à l'existence de centres diffuseurs ayant des états d'énergies et de populations différentes, fait l'objet du

  20. Evaluation d’un enseignement par les étudiants appliquée au module « aide à la rédaction de thèse»: destiné aux internes des hôpitaux des Armées au Centre d’épidémiologie et de Santé Publique des Armées, Marseille

    PubMed Central

    Kasouati, Jalal; Velut, Guillaume; Deparis, Xavier; Touloune, Farida

    2016-01-01

    Introduction En éducation, l'évaluation concerne les institutions de formation, les programmes, les enseignants ou les étudiants. Elle peut être prédictive, sommative ou formative. L'Evaluation d'un Enseignement par les Etudiants (EEE) est l'un des outils de ce dernier type. Objectif Évaluer l'enseignement de la première partie de la formation « aide à la rédaction de thèse ». Méthodes C'est une étude transversale classée dans le cadre « EEE » qui a porté sur le module « aide à la rédaction de thèse » dispensée au CESPA au profit de 27 participants préparant leur projet de fin d'étude. Résultats Le taux de réponse des participants présents était de 100%. D'un sexe ratio F/M de 2 et de une moyenne d'âge de 25,5 ans +/- 2,7 ans, les questionnés étaient majoritairement des internes de médecine générale. Plus de 85% affirmait n'avoir bénéficié d'aucune formation au préalable dans les domaines traités. Les participants avaient des attentes qui rejoignaient sommairement les objectifs de la formation. A part le rythme jugé non adapté par plus de la moitié, 80% des participants ont été satisfaits des autres aspects évalués et 95,8% parmi eux prévoyaient d'assister à la deuxième partie de la formation Pour tout les participants, la formation a permis d'amélioré de façon significative leur connaissance et aurais certainement un impact positif sur leurs travaux de recherche. Conclusion Notre travail était un moyen d'installer une certaine complicité entre les étudiants et les enseignants pour atteindre un objectif commun: « AMELIORER LA FORMATION ». PMID:27800091

  1. Evaluation of Different Types of Lasers in Surface Conditioning of Porcelains: A Review Article

    PubMed Central

    Mirhashemi, Amirhossin; Sharifi, Nastaran; Moharrami, Mohammad; Chiniforush, Nasim

    2017-01-01

    To achieve proper bond strength for porcelains, adequate surface roughness is essential, which is traditionally gained by sandblasting or acid etching with hydrofluoric (HF) acid. Nowadays with the development of laser systems, serious efforts were made to apply this new instrument for surface etching of porcelains due to easy usage, safety, and more efficiency. There are different kinds of lasers and porcelains, so choosing the ones which will be good match for each other is crucial. Besides that, changing the irradiation setting can be beneficial as well. This article reviewed 33 related studies and summarized results of etching accomplished by Nd:YAG, Er:YAG, Er,Cr:YSGG and CO2 lasers on different types of porcelains considering different laser settings and evaluation methods to bring a comprehensive insight. PMID:29123628

  2. Facilities to Support Beamed Energy Launch Testing at the Laser Hardened Materials Evaluation Laboratory (LHMEL)

    NASA Astrophysics Data System (ADS)

    Lander, Michael L.

    2003-05-01

    The Laser Hardened Materials Evaluation Laboratory (LHMEL) has been characterizing material responses to laser energy in support of national defense programs and the aerospace industry for the past 26 years. This paper reviews the overall resources available at LHMEL to support fundamental materials testing relating to impulse coupling measurement and to explore beamed energy launch concepts. Located at Wright-Patterson Air Force Base, Ohio, LHMEL is managed by the Air Force Research Laboratory Materials Directorate AFRL/MLPJ and operated by Anteon Corporation. The facility's advanced hardware is centered around carbon dioxide lasers producing output power up to 135kW and neodymium glass lasers producing up to 10 kilojoules of repetitively pulsed output. The specific capabilities of each laser device and related optical systems are discussed. Materials testing capabilities coupled with the laser systems are also described including laser output and test specimen response diagnostics. Environmental simulation capabilities including wind tunnels and large-volume vacuum chambers relevant to beamed energy propulsion are also discussed. This paper concludes with a summary of the procedures and methods by which the facility can be accessed.

  3. [A comparative evaluation of the efficacy of magneto- and laser therapy in patients with osteoarthrosis deformans].

    PubMed

    Selivonenko, V G; Syvolap, V D; Porada, L V; Medvedeva, V N; Boev, S S; Morozov, A I; Slin'ko, V G; Berest, S M; Garbuz, L N; Sholokh, S G

    1997-01-01

    A comparative evaluation of efficacy of magneto- and laser therapy was carried out in 82 patients with osteoarthrosis deformans. The magnetic field and laser irradiation dispelled the pain syndrome and synovitis manifestations. It is recommendable that the multiple-modality therapy of patients with osteoarthrosis deformans should involve magneto- and laser therapy (15 to 20 procedures per one course) that improve results of the treatment being received and allow the time of hospitalization to be reduced at an average by 5 bed-days. Laser appeared to be a very effective mode of treatment. No unfavourable side effects were recordable.

  4. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    NASA Astrophysics Data System (ADS)

    Attrill, David Cameron

    Lasers have become increasingly established in medicine as effective alternatives or adjuncts to conventional techniques. In dentistry, several clinical laser systems have been developed and marketed, but their applications have been limited to soft tissue surgery. To date, no laser has been capable of effectively cutting or modifying the highly mineralised dental tissues of enamel and dentine. The aim of this study was to evaluate two new laser systems for use in dentistry through a series of in vitro experiments. Both generic erbium and holmium lasers have theoretically superior operating characteristics over currently established lasers for applications with dental hard tissues. The two lasers investigated in this study were pulsed Er:YAG (lambda=2.94) a.m. and Cr-Tm-Ho:YAG (lambda=2.1mu.m). Both operated with a macropulse duration of approximately 200lambdas, at pulse repetition rates of 2-8Hz and mean pulse energies up to 230mJ. Radiation was focused using CaF[2] lenses (f=50-120mm). The lasers could be operated with or without the addition of a surface water film at the interaction site. Tissue removal efficiency was expressed as a latent heat of ablation (LHA, kJ/cm[3]) using a modification of the technique described by Charlton et al. (1990). The mean LHA's for the Er:YAG laser were 6.24kJ/cm[3] and 22.99kJ/cm[3] with dentine and enamel respectively without water, and 10.07kJ/cm[3] and 18.73kJ/cm[3] for dentine and enamel with water. The Cr-Tm-Ho:YAG laser was unable to effectively remove enamel at the fluences and pulse energies available; the mean LHA's for the Cr-Tm- Ho:YAG laser with dentine were 82.79kJ/cm3 and 57.57kJ/cm3 with and without water respectively. The Cr-Tm-Ho;YAG was approximately 8-9 times less efficient for tissue removal than the Er:YAG system. Er:YAG tissue removal with water was characterised by clean "surgical" cuts, comparable in histological appearance to those obtained using conventional instrumentation. Some thermal disruption

  5. Evaluation de la formation des résidents en chirurgie générale et digestive en Tunisie

    PubMed Central

    Mahmoudi, Ammar; Noomen, Faouzi; Nasr, Mohamed; Zouari, Khadija; Hamdi, Abdelaziz

    2015-01-01

    Introduction De nombreux moyens sont mis à disposition des résidents en chirurgie générale et digestive pour assurer leur formation théorique et pratique. Cependant, le niveau d'utilisation de ces différents outils et leur impact sur la formation des résidents n'ont jamais été évalués. L'objectif de notre étude était d’étudier l’état des lieux des moyens de formation utilisés par les résidents pour évaluer leurs degrés de satisfaction et leurs propositions en vue d'améliorer leur formation. Méthodes Un questionnaire anonyme a été distribué aux résidents de chirurgie générale et digestive de l'année 2012-2013. Ce questionnaire portait sur les caractéristiques démographiques, les ressources pédagogiques, ainsi que le cursus médical et universitaire. Une évaluation de la formation ainsi qu'un recueil des propositions faites en vue d'améliorer leurs formations étaient réalisées. Résultats Cinquante résidents sur 83 ont répondu au questionnaire. L'orientation de carrière la plus fréquente était l'hospitalo-universitaire dans 70% des cas. La pratique quotidienne et l'internet étaient les deux ressources pédagogiques les plus utilisées. La formation chirurgicale était jugée satisfaisante par seulement 10% des répondants. Parmi l'ensemble des propositions faites, l'apprentissage sur simulateur chirurgical, l'existence d'un ouvrage national de référence, et l'institution d'un tutorat par un chirurgien senior recueillaient plus de 80% d'avis favorable. Conclusion La majorité des résidents jugent leur formation non satisfaisante. Une meilleure information sur les ressources déjà existantes, un renforcement du compagnonnage et un accès plus large à un apprentissage sur simulateur chirurgical permettraient de diminuer ce sentiment d'insatisfaction. PMID:26587174

  6. Comparative evaluation of user interfaces for robot-assisted laser phonomicrosurgery.

    PubMed

    Dagnino, Giulio; Mattos, Leonardo S; Becattini, Gabriele; Dellepiane, Massimo; Caldwell, Darwin G

    2011-01-01

    This research investigates the impact of three different control devices and two visualization methods on the precision, safety and ergonomics of a new medical robotic system prototype for assistive laser phonomicrosurgery. This system allows the user to remotely control the surgical laser beam using either a flight simulator type joystick, a joypad, or a pen display system in order to improve the traditional surgical setup composed by a mechanical micromanipulator coupled with a surgical microscope. The experimental setup and protocol followed to obtain quantitative performance data from the control devices tested are fully described here. This includes sets of path following evaluation experiments conducted with ten subjects with different skills, for a total of 700 trials. The data analysis method and experimental results are also presented, demonstrating an average 45% error reduction when using the joypad and up to 60% error reduction when using the pen display system versus the standard phonomicrosurgery setup. These results demonstrate the new system can provide important improvements in terms of surgical precision, ergonomics and safety. In addition, the evaluation method presented here is shown to support an objective selection of control devices for this application.

  7. The desA and desB genes from Clostridium scindens ATCC 35704 encode steroid-17,20-desmolase.

    PubMed

    Devendran, Saravanan; Mythen, Sean M; Ridlon, Jason M

    2018-06-01

    Clostridium scindens is a gut microbe capable of removing the side-chain of cortisol, forming 11β-hydro-xyandrostenedione. A cortisol-inducible operon ( desABCD ) was previously identified in C. scindens ATCC 35704 by RNA-Seq. The desC gene was shown to encode a cortisol 20α-hydroxysteroid dehydrogenase (20α-HSDH). The desD encodes a protein annotated as a member of the major facilitator family, predicted to function as a cortisol transporter. The desA and desB genes are annotated as N-terminal and C-terminal transketolases, respectively. We hypothesized that the DesAB forms a complex and has steroid-17,20-desmolase activity. We cloned the desA and desB genes from C. scindens ATCC 35704 in pETDuet for overexpression in Escherichia coli The purified recombinant DesAB was determined to be a 142 ± 5.4 kDa heterotetramer. We developed an enzyme-linked continuous spectrophotometric assay to quantify steroid-17,20-desmolase. This was achieved by coupling DesAB-dependent formation of 11β-hydroxyandrostenedione with the NADPH-dependent reduction of the steroid 17-keto group by a recombinant 17β-HSDH from the filamentous fungus, Cochliobolus lunatus The pH optimum for the coupled assay was 7.0 and kinetic constants using cortisol as substrate were K m of 4.96 ± 0.57 µM and k cat of 0.87 ± 0.076 min -1 Substrate-specificity studies revealed that rDesAB recognized substrates regardless of 11β-hydroxylation, but had an absolute requirement for 17,21-dihydroxy 20-ketosteroids. Copyright © 2018 Devendran et al.

  8. Effets des electrons secondaires sur l'ADN

    NASA Astrophysics Data System (ADS)

    Boudaiffa, Badia

    Les interactions des electrons de basse energie (EBE) representent un element important en sciences des radiations, particulierement, les sequences se produisant immediatement apres l'interaction de la radiation ionisante avec le milieu biologique. Il est bien connu que lorsque ces radiations deposent leur energie dans la cellule, elles produisent un grand nombre d'electrons secondaires (4 x 104/MeV), qui sont crees le long de la trace avec des energies cinetiques initiales bien inferieures a 20 eV. Cependant, il n'y a jamais eu de mesures directes demontrant l'interaction de ces electrons de tres basse energie avec l'ADN, du principalement aux difficultes experimentales imposees par la complexite du milieu biologique. Dans notre laboratoire, les dernieres annees ont ete consacrees a l'etude des phenomenes fondamentaux induits par impact des EBE sur differentes molecules simples (e.g., N2, CO, O2, H2O, NO, C2H 4, C6H6, C2H12) et quelques molecules complexes dans leur phase solide. D'autres travaux effectues recemment sur des bases de l'ADN et des oligonucleotides ont montre que les EBE produisent des bris moleculaires sur les biomolecules. Ces travaux nous ont permis d'elaborer des techniques pour mettre en evidence et comprendre les interactions fondamentales des EBE avec des molecules d'interet biologique, afin d'atteindre notre objectif majeur d'etudier l'effet direct de ces particules sur la molecule d'ADN. Les techniques de sciences des surfaces developpees et utilisees dans les etudes precitees peuvent etre etendues et combinees avec des methodes classiques de biologie pour etudier les dommages de l'ADN induits par l'impact des EBE. Nos experiences ont montre l'efficacite des electrons de 3--20 eV a induire des coupures simple et double brins dans l'ADN. Pour des energies inferieures a 15 eV, ces coupures sont induites par la localisation temporaire d'un electron sur une unite moleculaire de l'ADN, ce qui engendre la formation d'un ion negatif transitoire

  9. Evaluation of dentin tubule occlusion after laser irradiation and desensitizing agent application.

    PubMed

    Kim, Min-Ho; Kim, Ryan Jin-Young; Lee, Woo-Cheol; Lee, In-Bog

    2015-10-01

    To evaluate the effects of lasers (Nd:YAG and Er:YAG) and of topical desensitizing agents on dentin tubule occlusion by measuring real-time dentin fluid flow (DFF). 32 molars were prepared with V-shape cavity at the cervical area, acid-etched, water rinsed, blotted dry, and treated with (1) Nd:YAG laser; (2) Er:YAG laser; (3) SuperSeal, a desensitizing agent; (4) ClinproXT, a resin-modified glass-ionomer (RMGI) varnish (n = 8 each). A real-time fluid flow measuring instrument (nano-Flow) was used to measure the DFF throughout the procedures. The DFF rates before and after the treatment were compared. Moreover, the surface topography of dentin tubules after each desensitizing method was examined using SEM. DFF varied among the groups. The DFF rate was significantly reduced after laser irradiation/application of the desensitizing agents (P < 0.05). ClinproXT showed the greatest reduction of DFF rate (71.9%), followed by the SuperSeal (34.8%) and laser groups (P< 0.05). However, there was no significant difference between the Nd:YAG (24.1%) and Er:YAG (20.6%) groups (P > 0.05). In SEM images, narrowed dentin tubules were observed in both lased groups and SuperSeal group. In the ClinproXT group, the occluded dentin tubules by the RMGI covering were observed.

  10. Evaluation of antimicrobial and thermal effects of diode laser on root canal dentin.

    PubMed

    Kıvanc, B H; Arısu, H D; Sağlam, B C; Akça, G; Gürel, M A; Görgül, G

    2017-12-01

    The aim of this study was to evaluate the antimicrobial effects of diode laser and temperature rise on the root surface during application. Thirty-six teeth were chemomechanically prepared and irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid, and then autoclaved and incubated with a suspension of Enterococcus faecalis. The specimens were randomly divided into three groups (n = 12): Group 1, irradiated by diode laser at 1.2 W; Group 2, irradiated by diode laser at 2 W; and Group 3, irradiated by diode laser at 3 W. The grown bacteria were counted and the mean numbers of the each test tube were determined. The temperature was measured on the external apical third of the root during laser application. The mean values of results for each group were compared using one-way analysis of variance and Tukey test. No significant difference was obtained among the test groups in terms of the colony counts (P > 0.05). According to the temperature changes, there was a significant difference between groups (P < 0.05). Temperature rises were 16.79°C, 10.20°C, and 6.25°C in Group 3, Group 2, and Group 1, respectively. Diode laser irradiation with 1.2 W demonstrated comparable performance with 2 W and 3 W power sets for elimination of E. faecalis from root canal with less temperature rise.

  11. Evaluation of Static Friction of Polycrystalline Ceramic Brackets after Conditioning with Different Powers of Er:YAG Laser.

    PubMed

    Arash, Valiollah; Javanmard, Saeed; Eftekhari, Zeinab; Rahmati-Kamel, Manouchehr; Bahadoram, Mohammad

    2015-01-01

    This research aimed to reduce the friction between the wire and brackets by Er:YAG laser. To measure the friction between the wires and brackets in 0° and 10° of wire angulations, 40 polycrystalline ceramic brackets (Hubit, South Korea) were divided into 8 study groups and irradiated by 100, 200, and 300 mj/s of Er:YAG laser power. Two groups of brackets were not irradiated. The friction between the wires and brackets was measured with universal testing machine (SANTAM) with a segment of .019 × .025 SS wire pulled out of the slot of bracket. ANOVA and t-test were used for analyzing the results. To evaluate the effect of the laser on surface morphology of the bracket, SEM evaluations were carried out. The mean frictional resistances between the brackets and wires with 0° of angulation by increasing the laser power decreased compared with control group, but, in 10° of angulation, the friction increased regardless of the laser power and was comparable to the friction of nonirradiated brackets. Furthermore, with each laser power, frictional resistance of brackets in 10° of angulation was significantly higher than 0° of angulation. These results were explained by SEM images too.

  12. Effect of GaAs Laser at 904 nm in the Pain Threshold in Tibia and Tolerance in Deltoid Evaluated by Pressure Algometry

    NASA Astrophysics Data System (ADS)

    Soares, Luiz G. P.; Sato, Sidney K.; Silveira, Landulfo; Aimbire, Flávio; Moreira, Leonardo M.; Pinheiro, Antônio L. B.

    2011-08-01

    The use of LLLT in pain relief is a controversial issue in Physiotherapy, with the efficacy of LLLT associated to pain relief still requiring significant study. Objective. This work focuses on the evaluation of the effect of low power GaAs laser at 904 nm in pressure pain threshold and tolerance in tibia and deltoid muscle, respectively. A total of 17 subjects were divided in two groups: active and sham laser. Measurements were taken before and after laser irradiation in healthy individuals using a pressure algometry, first verifying the viability of algometry to evaluate the pain threshold and tolerance inter individuals and comparing the differences of right and left sides in the same patients, and finally evaluating the pain threshold and tolerance before and after a single laser application. Laser energy density was of 4.0 J/cm2 with power density of 137 mW/cm2. Comparing algometry values of active laser group and the sham group, the pain tolerance in the deltoid muscle did not change among groups after laser irradiation, while it was also encountered a statistically significant difference in the pain threshold in tibia when comparing the laser active and sham laser (p<0.05). It was found that the active laser was effective in maintaining the pain threshold in tibia. The effective laser action in raising the pain threshold in tibia upon healthy individuals can suggest that the laser could be applied not only as curative but also with preventive purpose.

  13. Evaluation of a commercially available passively Q-switched Nd:YAG laser with LiF: F2- saturable absorber for laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Carson, Cantwell G.; Goueguel, Christian L.; Sanghapi, Hervé; Jain, Jinesh; McIntyre, Dustin

    2016-05-01

    Interest in passively Q-switched microchip lasers as a means for miniaturization of laser-induced breakdown spectroscopy (LIBS) apparatus has rapidly grown in the last years. To explore the possibility of using a comparatively UV-vis transparent absorber, we herein present the first report on the evaluation of a commercially available flash lamp-pumped passively Q-switched Nd:YAG laser with LiF: F2- saturable absorber as an excitation source in LIBS. Quantitative measurements of barium, strontium, rubidium and lithium in granite, rhyolite, basalt and syenite whole-rock glass samples were performed. Using a gated intensified benchtop spectrometer, limits of detection of 0.97, 23, 37, and 144 ppm were obtained for Li, Sr, Rb, and Ba, respectively. Finally, we discuss the advantages of using such a laser unit for LIBS applications in terms of ablation efficiency, analytical performances, output energy, and standoff capabilities.

  14. Clinical evaluation and treatment accuracy in diabetic macular edema using navigated laser photocoagulator NAVILAS.

    PubMed

    Kozak, Igor; Oster, Stephen F; Cortes, Marco A; Dowell, Dennis; Hartmann, Kathrin; Kim, Jae Suk; Freeman, William R

    2011-06-01

    To evaluate the clinical use and accuracy of a new retinal navigating laser technology that integrates a scanning slit fundus camera system with fluorescein angiography (FA), color, red-free, and infrared imaging capabilities with a computer steerable therapeutic 532-nm laser. Interventional case series. Eighty-six eyes of 61 patients with diabetic retinopathy and macular edema treated by NAVILAS. The imaging included digital color fundus photographs and FA. The planning included graphically marking future treatment sites (microaneurysms for single-spot focal treatment and areas of diffuse leakage for grid pattern photocoagulation) on the acquired images. The preplanned treatment was visible and overlaid on the live fundus image during the actual photocoagulation. The NAVILAS automatically advances the aiming beam location from one planned treatment site to the next after each photocoagulation spot until all sites are treated. Aiming beam stabilization compensated for patient's eye movements. The pretreatment FA with the treatment plan was overlaid on top of the posttreatment color fundus images with the actual laser burns. This allowed treatment accuracy to be calculated. Independent observers evaluated the images to determine if the retinal opacification after treatment overlapped the targeted microaneurysm. Safety and accuracy of laser photocoagulation. The images were of very good quality compared with standard fundus cameras, allowing careful delineation of target areas on FA. Toggling from infrared, to monochromatic, to color view allowed evaluation and adjustment of burn intensity during treatment. There were no complications during or after photocoagulation treatment. An analysis of accuracy of 400 random focal targeted spots found that the NAVILAS achieved a microaneurysm hit rate of 92% when the placement of the treatment circle was centered by the operating surgeon on the microaneurysm. The accuracy for the control group analyzing 100 focal spots was

  15. Aircraft Disinsection: A Guide for Military and Civilian Air Carriers (Desinsectisation des aeronefs: Un guide a l’intention des responsables des transports aeriens civils et militaires)

    DTIC Science & Technology

    1996-04-01

    regulations. - Ceratitis capitata (Mediterranean fruit fly). Quarantine regulations generally reduce - Rhagoletis pomonella (Apple maggot). the chances of a...d’insectes nuisibles dans un pays, en 6vitant des risques pour la sant6 des 6quipages, pour la s~curit6 de 1’a~ronef et pour l’industrie. Ce rapport examine 1...diffrrents officiels responsables de la r~glementation des insectes nuisibles introduits, de l’inscription des pesticides et de leur utilisation en

  16. Non-destructive Magnetic Evaluation of Laser Weld Quality in Hot Rolled Coils

    NASA Astrophysics Data System (ADS)

    Mohapatra, J. N.; Chakradhar, I.; Rao, K. R. C.; Rao, V. V. L.; Kaza, Marutiram

    2015-06-01

    Weld quality evaluation was conducted on laser welded thin sectsions (2 mm) of hot-rolled (HR) low-carbon steel coils during cold rolling process. The analysis revealed that the poor welds consisting of the weld defects like incomplete fusion, cluster of porosity, and large difference in hardness between the weld zone and base metal were responsible for the weld failures. Experiments were conducted by varying the welding parameters; laser power and welding speed to optimize the parameters for minimizing the weld defects. The optimized weld process parameters have helped elimination of weld defects and the results are verified with microscopy and microhardness measurements. As destructive evaluation techniques are time consuming and not always permitted in industrial applications, attempts have been made in the present investigation for the utilization of suitable non-destructive techniques for the evaluation of weld quality. Non-destructive magnetic techniques of magnetic hysteresis loop and magnetic Barkhausen emissions were used in the present investigation to establish possible correlations of magnetic properties across the weld seam with the mechanical property (microhardness) for evaluation of weld quality. It is inferred that the magnetic properties of coercivity and inverse of root mean square voltage can be effectively utilized to determine weld quality in HR steel coils.

  17. Developpement d'une methode calorimetrique de mesure des pertes ac pour des rubans supraconducteurs a haute temperature critique

    NASA Astrophysics Data System (ADS)

    Dolez, Patricia

    Le travail de recherche effectue dans le cadre de ce projet de doctorat a permis la mise au point d'une methode de mesure des pertes ac destinee a l'etude des supraconducteurs a haute temperature critique. Pour le choix des principes de cette methode, nous nous sommes inspires de travaux anterieurs realises sur les supraconducteurs conventionnels, afin de proposer une alternative a la technique electrique, presentant lors du debut de cette these des problemes lies a la variation du resultat des mesures selon la position des contacts de tension sur la surface de l'echantillon, et de pouvoir mesurer les pertes ac dans des conditions simulant la realite des futures applications industrielles des rubans supraconducteurs: en particulier, cette methode utilise la technique calorimetrique, associee a une calibration simultanee et in situ. La validite de la methode a ete verifiee de maniere theorique et experimentale: d'une part, des mesures ont ete realisees sur des echantillons de Bi-2223 recouverts d'argent ou d'alliage d'argent-or et comparees avec les predictions theoriques donnees par Norris, nous indiquant la nature majoritairement hysteretique des pertes ac dans nos echantillons; d'autre part, une mesure electrique a ete realisee in situ dont les resultats correspondent parfaitement a ceux donnes par notre methode calorimetrique. Par ailleurs, nous avons compare la dependance en courant et en frequence des pertes ac d'un echantillon avant et apres qu'il ait ete endommage. Ces mesures semblent indiquer une relation entre la valeur du coefficient de la loi de puissance modelisant la dependance des pertes avec le courant, et les inhomogeneites longitudinales du courant critique induites par l'endommagement. De plus, la variation en frequence montre qu'au niveau des grosses fractures transverses creees par l'endommagement dans le coeur supraconducteur, le courant se partage localement de maniere a peu pres equivalente entre les quelques grains de matiere

  18. Acousto-ultrasonic nondestructive evaluation of materials using laser beam generation and detection. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Huber, Robert D.; Green, Robert E., Jr.

    1990-01-01

    The acousto-ultrasonic method has proven to be a most interesting technique for nondestructive evaluation of the mechanical properties of a variety of materials. Use of the technique or a modification thereof, has led to correlation of the associated stress wave factor with mechanical properties of both metals and composite materials. The method is applied to the nondestructive evaluation of selected fiber reinforced structural composites. For the first time, conventional piezoelectric transducers were replaced with laser beam ultrasonic generators and detectors. This modification permitted true non-contact acousto-ultrasonic measurements to be made, which yielded new information about the basic mechanisms involved as well as proved the feasibility of making such non-contact measurements on terrestrial and space structures and heat engine components. A state-of-the-art laser based acousto-ultrasonic system, incorporating a compact pulsed laser and a fiber-optic heterodyne interferometer, was delivered to the NASA Lewis Research Center.

  19. Cartographie des disques

    NASA Astrophysics Data System (ADS)

    Hameury, Jean-Marie

    2001-01-01

    Two techniques are frequently used to produce images of the accretion disc in an eclipsing binary: eclipse mapping and Doppler tomography. From the light curve, one can deduce the radial distribution of the effective temperature, assuming axial symmetry. On the other hand, from the variation of the line profile one can reconstruct an image in the velocity space, which can be converted into a real image if one knows the kinematics of the system. Deux techniques sont couramment utilisées pour obtenir des images des disques dans les systèmes binaires à éclipses. En utilisant la courbe de lumière, on peut remonter à la distribution radiale de la brillance de surface, en supposant que celle-ci a une symètrie axiale. D'autre part, les profils de raies renseignent sur la distribution de vitesse des régions émissives leur variation temporelle permet de réaliser une image dans l'espace des vitesses, que l'on peut ensuite transformer en carte dans l'espace (x,y) si on connaît la cinématique du système.

  20. Measurement of the Carbon Isotopic Composition of Methane Using Helicoidal Laser Eigenstates

    NASA Astrophysics Data System (ADS)

    Jacob, D.; Le Floch, A.; Bretenaker, F.; Guenot, P.

    1996-06-01

    The spatially generalized Jones matrix formalism is used to design a laser cavity to make intracavity measurements of the carbon isotopic composition of methane. the method is based on a double optical lever effect for helicoidally polarized eigenstates, permitting to measure successively the ^{12}CH_4 and ^{13}CH_4 concentrations. To choose the probed isotope, one simply tunes the frequency of the laser by Zeeman effect. The experiment exhibits a good agreement with the predictions and permits to measure the ^{13}CH4/^{12}CH_4 composition ratio of methane with an uncertainty of the order of ± 0.07% for a sample containing only 6× 10^{-9} mole of methane. On utilise le formalisme des matrices de Jones généralisées spatialement pour concevoir une cavité laser permettant la mesure intra-cavité de la composition isotopique du carbone présent dans le méthane. La méthode est fondée sur une double application de l'effet de levier optique pour les états propres hélicoïdaux, permettant de mesurer successivement les concentrations de ^{12}CH_4 et de ^{13}CH_4. Pour passer d'un isotope à l'autre, on ajuste simplement la fréquence du laser par effet Zeeman. L'expérience est en bon accord avec les prédictions et permet d'effectuer la mesure du rapport isotopique ^{13}CH4/^{12}CH_4 avec une fourchette d'incertitude de ± 0,07% pour des échantillons de gaz ne contenant que 6× 10^{-9} mole de méthane.

  1. Strategies facilitant les tests en pre-certification pour la robustesse a l'egard des radiations =

    NASA Astrophysics Data System (ADS)

    Souari, Anis

    Les effets des radiations cosmiques sur l'electronique embarquee preoccupent depuis. quelques decennies les chercheurs interesses par la robustesse des circuits integres. Plusieurs. recherches ont ete menees dans cette direction, principalement pour les applications spatiales. ou l’environnement de leur deploiement est hostile. En effet, ces environnements sont denses. en termes de particules qui, lorsqu’elles interagissent avec les circuits integres, peuvent. mener a leur dysfonctionnement, voir meme a leur destruction. De plus, les effets des. radiations s’accentuent pour les nouvelles generations des circuits integres ou la diminution. de la taille des transistors et l’augmentation de la complexite de ces circuits augmentent la. probabilite d’apparition des anomalies et par consequence la croissance des besoins de test. L’expansion de l’electronique grand public (commercial off-the-shelf, COTS) et l’adoption. de ces composants pour des applications critiques comme les applications avioniques et. spatiales incitent egalement les chercheurs a doubler les efforts de verification de la fiabilite. de ces circuits. Les COTS, malgre leurs meilleures caracteristiques en comparaison avec les. circuits durcis tolerants aux radiations qui sont couteux et en retard en termes de technologie. utilisee, sont vulnerables aux radiations. Afin d’ameliorer la fiabilite de ces circuits, une evaluation de leur vulnerabilite dans les. differents niveaux d’abstraction du flot de conception est recommandee. Ceci aide les. concepteurs a prendre les mesures de mitigation necessaires sur le design au niveau. d’abstraction en question. Enfin, afin de satisfaire les exigences de tolerance aux pannes, des. tests tres couteux de certification, obtenus a l’aide de bombardement de particules (protons, neutrons, etc.), sont necessaires. Dans cette these, nous nous interessons principalement a definir une strategie de precertification

  2. Sealing ability of three root-end filling materials prepared using an erbium: Yttrium aluminium garnet laser and endosonic tip evaluated by confocal laser scanning microscopy

    PubMed Central

    Nanjappa, A Salin; Ponnappa, KC; Nanjamma, KK; Ponappa, MC; Girish, Sabari; Nitin, Anita

    2015-01-01

    Aims: (1) To compare the sealing ability of mineral trioxide aggregate (MTA), Biodentine, and Chitra-calcium phosphate cement (CPC) when used as root-end filling, evaluated under confocal laser scanning microscope using Rhodamine B dye. (2) To evaluate effect of ultrasonic retroprep tip and an erbium:yttrium aluminium garnet (Er:YAG) laser on the integrity of three different root-end filling materials. Materials and Methods: The root canals of 80 extracted teeth were instrumented and obturated with gutta-percha. The apical 3 mm of each tooth was resected and 3 mm root-end preparation was made using ultrasonic tip (n = 30) and Er:YAG laser (n = 30). MTA, Biodentine, and Chitra-CPC were used to restore 10 teeth each. The samples were coated with varnish and after drying, they were immersed in Rhodamine B dye for 24 h. The teeth were then rinsed, sectioned longitudinally, and observed under confocal laser scanning microscope. Statistical Analysis Used: Data were analyzed using one-way analysis of variance (ANOVA) and a post-hoc Tukey's test at P < 0.05 (R software version 3.1.0). Results: Comparison of microleakage showed maximum peak value of 0.45 mm for Biodentine, 0.85 mm for MTA, and 1.05 mm for Chitra-CPC. The amount of dye penetration was found to be lesser in root ends prepared using Er:YAG laser when compared with ultrasonics, the difference was found to be statistically significant (P < 0.05). Conclusions: Root-end cavities prepared with Er:YAG laser and restored with Biodentine showed superior sealing ability compared to those prepared with ultrasonics. PMID:26180420

  3. Effets perturbateurs endocriniens des pesticides organochlores.

    PubMed

    Charlier, C; Plomteux, G

    2002-01-01

    Xenoestrogens such organochlorine pesticides are known to induce changes in reproductive development, function or behaviour in wildlife. Because these compounds are able to modify the estrogens metabolism, or to compete with estradiol for binding to the estrogen receptor, it may be possible that these products affect the risk of developing impaired fertility, precocious puberty or some kinds of cancer in man. Le plus ancien récit de lutte contre la pollution remonte à une légende indienne racontant que la divinité Sing-bonga était incommodée par les émanations des fours dans lesquels les Asuras fondaient leurs métaux (1). Evidemment depuis, la problématique n-a cessé de s-accroître et la contamination de la Terre par de nombreux polluants est devenue aujourd-hui un problème majeur de notre Société. La protection de notre environnement est une question capitale qui doit être respectée malgré la pression économique actuelle et qui ne cessera de croître au cours des prochaines années même si l-identification objective et indiscutable de ce qui est essentiel - donc devant être prioritairement garanti sur la planète - est difficile à cerner (2). « Un oiseau en mauvais état ne pond pas de bons oeufs » disait un proverbe grec. Mais ce n-est qu-à partir de la seconde moitié du XXème siècle que les toxicologues ont commencé à identifier les effets qu-avaient entraînés à l-échelle mondiale les pollutions émises aux XIXème siècle sur la faune sauvage et sur le cheptel (3). L-histoire contemporaine des pesticides industriels commence vers 1874 (synthèse des organochlorés) et se poursuit tout au long de ces 2 siècles en passant par la synthèse des organophosphorés (1950), des carbamates (1970) et des pyréthroïdes (1975) (4). Le dichlorodiphényltrichloroéthane (DDT) a été synthétisé pour la première fois par un étudiant en cours de préparation de sa thèse de doctorat : Othmer Zeidler. La production, reprise par les

  4. In vitro evaluation of enamel demineralization after several overlapping CO2 laser applications.

    PubMed

    Vieira, K A; Steiner-Oliveira, C; Soares, L E S; Rodrigues, L K A; Nobre-dos-Santos, M

    2015-02-01

    This study aimed to evaluate the effects of repeated CO2 laser applications on the inhibition of enamel demineralization. Sixty-five human dental enamel slabs were randomly assigned to the following groups (n = 13): control (C), one application of the CO2 laser (L1), two applications of the CO2 laser (L2), three applications of the CO2 laser (L3), and four applications of the CO2 laser (L4). Enamel slabs were irradiated by a 10.6-μm CO2 laser operating at 5 J/cm(2). The slabs were subjected to a pH-cycling regimen and then analyzed by FT-Raman spectroscopy, energy-dispersive X-ray fluorescence spectrometry (EDXRF), cross-sectional micro-hardness, and scanning electron microscopy (SEM). Statistical analysis was performed using ANOVA and Tukey tests (p < 0.05). FT-Raman spectroscopy showed a reduced carbonate content for L1, L3, and L4 groups when compared to C (p < 0.05). The EDXRF data showed no statistical differences between the control and irradiated groups for calcium and phosphorus components (p > 0.05). Cross-sectional micro-hardness data showed a statistically significant difference between the control and all irradiated groups (p < 0.05), but no difference was found among the irradiated groups (p > 0.05) up to 30-μm depth. A tendency of lower demineralization occurred in deeper depths for L3 and L4 groups. The SEM results showed that with repeated applications of the CO2 laser, a progressive melting and recrystallization of the enamel surface occurred. Repeated irradiations of dental enamel may enhance the inhibition of enamel demineralization.

  5. Evaluation of the bond strength of resin cements used to lute ceramics on laser-etched dentin.

    PubMed

    Giray, Figen Eren; Duzdar, Lale; Oksuz, Mustafa; Tanboga, Ilknur

    2014-07-01

    The purpose of this study was to investigate the shear bond strength (SBS) of two different adhesive resin cements used to lute ceramics on laser-etched dentin. Erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) laser irradiation has been claimed to improve the adhesive properties of dentin, but results to date have been controversial, and its compatibility with existing adhesive resin cements has not been conclusively determined. Two adhesive cements, one "etch-and-rinse" [Variolink II (V)] and one "self-etch" [Clearfil Esthetic Cement (C)] luting cement, were used to lute ceramic blocks (Vita Celay Blanks, Vita) onto dentin surfaces. In total, 80 dentin specimens were distributed randomly into eight experimental groups according to the dentin surface-etching technique used Er,Cr:YSGG laser and Er:YAG laser: (1) 37% orthophosphoric acid+V (control group), (2) Er,Cr:YSGG laser+V, (3) Er,Cr:YSGG laser+acid+V, (4) Er:YAG laser+V, (5) Er:YAG laser+acid+V, (6) C, (7) Er,Cr:YSGG laser+C, and (8) Er:YAG laser+C. Following these applications, the ceramic discs were bonded to prepared surfaces and were shear loaded in a universal testing machine until fracture. SBS was recorded for each group in MPa. Shear test values were evaluated statistically using the Mann-Whitney U test. No statistically significant differences were evident between the control group and the other groups (p>0.05). The Er,Cr:YSGG laser+A+V group demonstrated significantly higher SBS than did the Er,Cr:YSGG laser+V group (p=0.034). The Er,Cr:YSGG laser+C and Er:YAG laser+C groups demonstrated significantly lower SBS than did the C group (p<0.05). Dentin surfaces prepared with lasers may provide comparable ceramic bond strengths, depending upon the adhesive cement used.

  6. Evaluation des indicateurs d’alerte précoce de la résistance du VIH aux ARV en Côte d’Ivoire en 2011

    PubMed Central

    Yao, Kouadio Jean; Damey, Néto Florence; Konan, Diby Jean Paul; Aka, Joseph; Aka-Konan, Sandrine; Ani, Alex; Bonle, Marguerite Te; Kouassi, Dinard

    2016-01-01

    Introduction En 2001, l'Organisation des Nations Unies recommandait de rendre disponible les médicaments antirétroviraux dans les pays à ressources limitées. Cependant, l'utilisation de ces médicaments à grande échelle s'accompagne du développement de résistance du virus. En Côte d'Ivoire, plusieurs sites prescrivent les antirétroviraux. Cette étude avait pour objectif d'évaluer les facteurs programmatiques associés à un risque élevé d'émergence de résistance du VIH aux antirétroviraux. Méthodes Il s'agit d'une cohorte rétrospective sur 20 sites de prise en charge des personnes vivant avec le VIH. La population d'étude était constituée des personnes ayant initié leur traitement antirétroviral sur les sites en 2008-2009. L'estimation de la taille de l'échantillon a été faite à partir de la stratégie d'échantillonnage de l'OMS. Résultats Sur 20 sites, 98% des prescriptions initiales étaient conformes aux directives nationales et 20% des sites avaient 100% de prescriptions conformes. Au total, 33% des patients étaient perdus de vue au cours des 12 premiers mois de traitement antirétroviral et 20% des sites avaient moins de 20% de perdus de vue. A 12 mois, 51% des patients demeuraient sous traitement de première intention approprié et 11% des sites ont atteint le seuil d'au moins 70% de patients sous traitement de première intention approprié. Un seul site n'a pas connu de rupture d'antirétroviraux sur les 12 mois. Conclusion Des insuffisances relevées dans la prise en charge des personnes vivant avec le VIH traduisent l'existence d'un risque important de résistance du virus aux antirétroviraux en 2008-2009. Pour minimiser ce risque les pratiques de prescription devraient être améliorées, un système de recherche des absents aux rendez-vous devrait être mis en place et la disponibilité constante des antirétroviraux devraient être assurée. PMID:28250876

  7. Identification des parametres du moteur de l'avion Cessna Citation X pour la phase de croisiere a partir des tests en vol et a base des reseaux de neurones =

    NASA Astrophysics Data System (ADS)

    Zaag, Mahdi

    La disponibilite des modeles precis des avions est parmi les elements cles permettant d'assurer leurs ameliorations. Ces modeles servent a ameliorer les commandes de vol et de concevoir de nouveaux systemes aerodynamiques pour la conception des ailes deformables des avions. Ce projet consiste a concevoir un systeme d'identification de certains parametres du modele du moteur de l'avion d'affaires americain Cessna Citation X pour la phase de croisiere a partir des essais en vol. Ces essais ont ete effectues sur le simulateur de vol concu et fabrique par CAE Inc. qui possede le niveau D de la dynamique de vol. En effet, le niveau D est le plus haut niveau de precision donne par l'autorite federale de reglementation FAA de l'aviation civile aux Etats-Unis. Une methodologie basee sur les reseaux de neurones optimises a l'aide d'un algorithme intitule le "grand deluge etendu" est utilisee dans la conception de ce systeme d'identification. Plusieurs tests de vol pour differentes altitudes et differents nombres de Mach ont ete realises afin de s'en servir comme bases de donnees pour l'apprentissage des reseaux de neurones. La validation de ce modele a ete realisee a l'aide des donnees du simulateur. Malgre la nonlinearite et la complexite du systeme, les parametres du moteur ont ete tres bien predits pour une enveloppe de vol determinee. Ce modele estime pourrait etre utilise pour des analyses de fonctionnement du moteur et pourrait assurer le controle de l'avion pendant cette phase de croisiere. L'identification des parametres du moteur pourrait etre realisee aussi pour les autres phases de montee et de descente afin d'obtenir son modele complet pour toute l'enveloppe du vol de l'avion Cessna Citation X (montee, croisiere, descente). Cette methode employee dans ce travail pourrait aussi etre efficace pour realiser un modele pour l'identification des coefficients aerodynamiques du meme avion a partir toujours des essais en vol. None None None

  8. Elaboration de nouvelles approches micromecaniques pour l'optimisation des performances mecaniques des materiaux heterogenes

    NASA Astrophysics Data System (ADS)

    Aboutajeddine, Ahmed

    Les modeles micromecaniques de transition d'echelles qui permettent de determiner les proprietes effectives des materiaux heterogenes a partir de la microstructure sont consideres dans ce travail. L'objectif est la prise en compte de la presence d'une interphase entre la matrice et le renforcement dans les modeles micromecaniques classiques, de meme que la reconsideration des approximations de base de ces modeles, afin de traiter les materiaux multiphasiques. Un nouveau modele micromecanique est alors propose pour tenir compte de la presence d'une interphase elastique mince lors de la determination des proprietes effectives. Ce modele a ete construit grace a l'apport de l'equation integrale, des operateurs interfaciaux de Hill et de la methode de Mori-Tanaka. Les expressions obtenues pour les modules globaux et les champs dans l'enrobage sont de nature analytique. L'approximation de base de ce modele est amelioree par la suite dans un nouveau modele qui s'interesse aux inclusions enrobees avec un enrobage mince ou epais. La resolution utilisee s'appuie sur une double homogeneisation realisee au niveau de l'inclusion enrobee et du materiau. Cette nouvelle demarche, permettra d'apprehender completement les implications des approximations de la modelisation. Les resultats obtenus sont exploites par la suite dans la solution de l'assemblage de Hashin. Ainsi, plusieurs modeles micromecaniques classiques d'origines differentes se voient unifier et rattacher, dans ce travail, a la representation geometrique de Hashin. En plus de pouvoir apprecier completement la pertinence de l'approximation de chaque modele dans cette vision unique, l'extension correcte de ces modeles aux materiaux multiphasiques est rendue possible. Plusieurs modeles analytiques et explicites sont alors proposee suivant des solutions de differents ordres de l'assemblage de Hashin. L'un des modeles explicite apparait comme une correction directe du modele de Mori-Tanaka, dans les cas ou celui ci echoue a

  9. Relation entre les caractéristiques des table-bancs et les mesures anthropométriques des écoliers au Benin

    PubMed Central

    Falola, Stève Marjelin; Gouthon, Polycarpe; Falola, Jean-Marie; Fiogbe, Michel Armand; Nigan, Issiako Bio

    2014-01-01

    Introduction Le mobilier scolaire et la posture assise en classe sont souvent impliqués dans l'apparition des douleurs rachidiennes, influant de fait sur la qualité des tâches réalisées par les apprenants. Aucune étude n'a encore vérifié le degré d'adéquation entre les caractéristiques du mobilier et celles des écoliers au Bénin. L'objectif de cette étude transversale est donc de déterminer la relation entre les dimensions des table-bancs utilisées en classe et les mesures anthropométriques des écoliers au Bénin. Methods Elle a été réalisée avec un échantillon probabiliste de 678 écoliers, âgés de 4 à 17 ans. Les mesures anthropométriques des écoliers et les mensurations relatives aux longueurs, largeurs et hauteurs des table-bancs ont été mesurées, puis intégrées aux équations proposées dans la littérature. Les pourcentages des valeurs situées hors des limitesacceptables, dérivées de l'application des équations ont été calculés. Results La largeur et la hauteur des table-bancs utilisées par les écoliers étaient plus élevées (p < 0,05) que les valeurs de référence recommandées par les structures officielles de contrôle et de production des mobiliers scolaires au Bénin. Quel que soit le sexe, il y avait une inadéquation entre la largeur du banc et la longueur fesse-poplité, puis entre la hauteur de la table et la distance coude-bancdes écoliers. Conclusion Les résultats suggèrent de prendre en compte l’évolution des mesures anthropométriques des écoliers dans la confection des table-bancs, afin de promouvoir de bonnes postures assises en classe et de réduire le risque de troubles du rachis. PMID:25317232

  10. Profil épidémiologique des tumeurs malignes primitives des glandes salivaires : à propos de 154 cas

    PubMed Central

    Setti, Khadija; Mouanis, Mohamed; Moumni, Abdelmounim; Maher, Mostafa; Harmouch, Amal

    2014-01-01

    Introduction Les tumeurs des glandes salivaires sont des tumeurs rares représentant 3à 5% des tumeurs de la tête et du cou. La classification de l'OMS 2005 distingue les tumeurs épithéliales, les tumeurs mésenchymateuses, les tumeurs hématologiques et les tumeurs secondaires. Méthodes Notre travail consiste en une étude rétrospective réalisée sur une période de 10 ans allant de janvier 2002 à janvier 2012. Les critères d'inclusion étaient: l'âge, le sexe, le siège de la tumeur et le type histologique. Résultats L'incidence annuelle des tumeurs malignes primitives des glandes salivaires dans notre série était de 15 cas par an. Cent cinquante quatre cas de tumeurs malignes primitives des glandes salivaires ont été colligés sans prédominance de sexe (78 femmes (50,6%) et 76 hommes (49,4%)). La moyenne d'âge était de 60 ans avec des extrêmes de 4 et 83 ans et un pic de fréquence entre 51et 70 ans. Deux tiers des cas (65%) avaient une localisation au niveau des glandes principales avec 66 cas au niveau de la parotide (43%) et 34 cas au niveau de la glande sous maxillaire (22%). Cinquante quatre patients avaient une tumeur maligne des glandes salivaires accessoires (35%) dont 61% au niveau du palais. Aucun cas de tumeur maligne de la glande sublinguale n'a été recensé dans notre étude. Le type histologique prédominant dans notre série était le carcinome adénoïde kystique et retrouvé chez 43 patients (27,9%), suivi de l'adénocarcinome sans autre indication chez 37 patients (24%) puis du carcinome mucoépidermoïde chez 16 patients (10,4%) et de l'adénocarcinome polymorphe de bas grade également chez 16 patients (10. 4%). Conclusion Les tumeurs malignes des glandes salivaires représentent un ensemble hétérogène de maladies de caractérisation complexe et de fréquence variable. PMID:25120861

  11. Using XML to encode TMA DES metadata.

    PubMed

    Lyttleton, Oliver; Wright, Alexander; Treanor, Darren; Lewis, Paul

    2011-01-01

    The Tissue Microarray Data Exchange Specification (TMA DES) is an XML specification for encoding TMA experiment data. While TMA DES data is encoded in XML, the files that describe its syntax, structure, and semantics are not. The DTD format is used to describe the syntax and structure of TMA DES, and the ISO 11179 format is used to define the semantics of TMA DES. However, XML Schema can be used in place of DTDs, and another XML encoded format, RDF, can be used in place of ISO 11179. Encoding all TMA DES data and metadata in XML would simplify the development and usage of programs which validate and parse TMA DES data. XML Schema has advantages over DTDs such as support for data types, and a more powerful means of specifying constraints on data values. An advantage of RDF encoded in XML over ISO 11179 is that XML defines rules for encoding data, whereas ISO 11179 does not. We created an XML Schema version of the TMA DES DTD. We wrote a program that converted ISO 11179 definitions to RDF encoded in XML, and used it to convert the TMA DES ISO 11179 definitions to RDF. We validated a sample TMA DES XML file that was supplied with the publication that originally specified TMA DES using our XML Schema. We successfully validated the RDF produced by our ISO 11179 converter with the W3C RDF validation service. All TMA DES data could be encoded using XML, which simplifies its processing. XML Schema allows datatypes and valid value ranges to be specified for CDEs, which enables a wider range of error checking to be performed using XML Schemas than could be performed using DTDs.

  12. Using XML to encode TMA DES metadata

    PubMed Central

    Lyttleton, Oliver; Wright, Alexander; Treanor, Darren; Lewis, Paul

    2011-01-01

    Background: The Tissue Microarray Data Exchange Specification (TMA DES) is an XML specification for encoding TMA experiment data. While TMA DES data is encoded in XML, the files that describe its syntax, structure, and semantics are not. The DTD format is used to describe the syntax and structure of TMA DES, and the ISO 11179 format is used to define the semantics of TMA DES. However, XML Schema can be used in place of DTDs, and another XML encoded format, RDF, can be used in place of ISO 11179. Encoding all TMA DES data and metadata in XML would simplify the development and usage of programs which validate and parse TMA DES data. XML Schema has advantages over DTDs such as support for data types, and a more powerful means of specifying constraints on data values. An advantage of RDF encoded in XML over ISO 11179 is that XML defines rules for encoding data, whereas ISO 11179 does not. Materials and Methods: We created an XML Schema version of the TMA DES DTD. We wrote a program that converted ISO 11179 definitions to RDF encoded in XML, and used it to convert the TMA DES ISO 11179 definitions to RDF. Results: We validated a sample TMA DES XML file that was supplied with the publication that originally specified TMA DES using our XML Schema. We successfully validated the RDF produced by our ISO 11179 converter with the W3C RDF validation service. Conclusions: All TMA DES data could be encoded using XML, which simplifies its processing. XML Schema allows datatypes and valid value ranges to be specified for CDEs, which enables a wider range of error checking to be performed using XML Schemas than could be performed using DTDs. PMID:21969921

  13. Thermal effects of Ho: YAG laser lithotripsy: real-time evaluation in an in vitro model.

    PubMed

    Hein, Simon; Petzold, Ralf; Schoenthaler, Martin; Wetterauer, Ulrich; Miernik, Arkadiusz

    2018-04-24

    To evaluate the thermal effect of Ho:YAG laser lithotripsy in a standardized in vitro model via real-time temperature measurement. Our model comprised a 20 ml test tube simulating the renal pelvis that was immersed in a 37 °C water bath. Two different laser fibers [FlexiFib (15-45 W), RigiFib 1000 (45-100 W), LISA laser products OHG, Katlenburg-Lindau, Germany] were placed in the test tube. An Ho:YAG 100 W laser was used in all experiments (LISA). Each experiment involved 120 s of continuous laser application, and was repeated five times. Different laser settings (high vs. low frequency, high vs. low energy, and long vs. short pulse duration), irrigation rates (0 up to 100 ml/min, realized by several pumps), and human calcium oxalate stone samples were analyzed. Temperature data were acquired by a real-time data logger with thermocouples (PICO Technology, Cambridgeshire, UK). Real-time measurements were assessed using MatLab ® . Laser application with no irrigation results in a rapid increase in temperature up to ∆28 K, rising to 68 °C at 100 W. Low irrigation rates yield significantly higher temperature outcomes. Higher irrigation rates result immediately in a lower temperature rise. High irrigation rates of 100 ml/min result in a temperature rise of 5 K at the highest laser power setting (100 W). Ho:YAG laser lithotripsy might be safe provided that there is sufficient irrigation. However, high power and low irrigation resulted in potentially tissue-damaging temperatures. Laser devices should, therefore, always be applied in conjunction with continuous, closely monitored irrigation whenever performing Ho:YAG laser lithotripsy.

  14. Bioheat model evaluations of laser effects on tissues: role of water evaporation and diffusion

    NASA Astrophysics Data System (ADS)

    Nagulapally, Deepthi; Joshi, Ravi P.; Thomas, Robert J.

    2011-03-01

    A two-dimensional, time-dependent bioheat model is applied to evaluate changes in temperature and water content in tissues subjected to laser irradiation. Our approach takes account of liquid-to-vapor phase changes and a simple diffusive flow of water within the biotissue. An energy balance equation considers blood perfusion, metabolic heat generation, laser absorption, and water evaporation. The model also accounts for the water dependence of tissue properties (both thermal and optical), and variations in blood perfusion rates based on local tissue injury. Our calculations show that water diffusion would reduce the local temperature increases and hot spots in comparison to simple models that ignore the role of water in the overall thermal and mass transport. Also, the reduced suppression of perfusion rates due to tissue heating and damage with water diffusion affect the necrotic depth. Two-dimensional results for the dynamic temperature, water content, and damage distributions will be presented for skin simulations. It is argued that reduction in temperature gradients due to water diffusion would mitigate local refractive index variations, and hence influence the phenomenon of thermal lensing. Finally, simple quantitative evaluations of pressure increases within the tissue due to laser absorption are presented.

  15. Les soins aux enfants et aux adolescents des familles des militaires canadiens : les considérations particulières

    PubMed Central

    Rowan-Legg, Anne

    2017-01-01

    Résumé Les familles des militaires font face à de nombreux facteurs de stress, tels que les réinstallations fréquentes, les longues pério des de séparation familiale, l’isolement géographique du réseau de soutien de la famille élargie et le déploiement en zones très dangereuses. Les enfants et les adolescents des familles des militaires vivent les mêmes trajectoires développementales et motivationnelles que leurs homologues civils, mais ils sont également aux prises avec des pressions et des facteurs de stress liés à leur développement qui sont inhabituels et qui leur sont imposés par les exigences de la vie militaire. Les effets de la vie militaire sur les familles et les enfants commencent à être admis et mieux caractérisés. Il est essentiel de comprendre les préoccupations propres aux enfants et aux adolescents des familles des militaires et de mobiliser les ressources nécessaires pour les soutenir afin de répondre à leurs besoins en matière de santé.

  16. Lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse

    PubMed Central

    Kahan, Meldon; Wilson, Lynn; Mailis-Gagnon, Angela; Srivastava, Anita

    2011-01-01

    Résumé Objectif Présenter aux médecins de famille un résumé clinique pratique sur la prescription d’opioïdes à des populations particulières en se fondant sur les recommandations faites dans les lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse. Qualité des données Pour produire les lignes directrices, les chercheurs ont effectué une synthèse critique de la littérature médicale en insistant plus précisément sur les études de l’efficacité et de la sécurité des opioïdes dans des populations particulières. Message principal Les médecins de famille peuvent atténuer les risques de surdose, de sédation, d’usage abusif et de dépendance grâce à des stratégies adaptées à l’âge et à l’état de santé des patients. Dans le cas de patients à risque de dépendance, on devrait réserver les opioïdes aux douleurs nociceptives ou neuropathiques bien définies qui n’ont pas répondu aux traitements de première intention. Il faut procéder lentement au titrage des opioïdes, avec des dispensations fréquentes et une étroite surveillance pour dépister tout signe d’usage abusif. Une dépendance aux opioïdes suspectée est prise en charge au moyen d’une thérapie structurée aux opioïdes, d’un traitement à la méthadone ou à la buprénorphine ou encore d’un traitement fondé sur l’abstinence. Les patients souffrant de troubles de l’humeur ou d’anxiété ont tendance à avoir une réponse analgésique atténuée aux opioïdes, sont à risque plus élevé d’usage abusif et prennent souvent des sédatifs qui interagissent défavorablement avec les opioïdes. Il faut prendre des précautions semblables à celles utilisées avec d’autres patients à risque élevé. Il faut faire un sevrage progressif si la douleur du patient demeure sévère même avec un essai adéquat de thérapie aux opioïdes. Chez les personnes âgées, la s

  17. L'astronomie des Anciens

    NASA Astrophysics Data System (ADS)

    Nazé, Yaël

    2009-04-01

    Quelle que soit la civilisation à laquelle il appartient, l'être humain cherche dans le ciel des réponses aux questions qu'il se pose sur son origine, son avenir et sa finalité. Le premier mérite de ce livre est de nous rappeler que l'astronomie a commencé ainsi à travers les mythes célestes imaginés par les Anciens pour expliquer l'ordre du monde et la place qu'ils y occupaient. Mais les savoirs astronomiques passés étaient loin d'être négligeables et certainement pas limités aux seuls travaux des Grecs : c'est ce que l'auteur montre à travers une passionnante enquête, de Stonehenge à Gizeh en passant par Pékin et Mexico, fondée sur l'étude des monuments anciens et des sources écrites encore accessibles. Les tablettes mésopotamiennes, les annales chinoises, les chroniques médiévales, etc. sont en outre d'une singulière utilité pour les astronomes modernes : comment sinon remonter aux variations de la durée du jour au cours des siècles, ou percer la nature de l'explosion qui a frappé tant d'observateurs en 1054 ? Ce livre offre un voyage magnifiquement illustré à travers les âges, entre astronomie et archéologie.

  18. Surgical treatment and optical coherence tomographic evaluation for accidental laser-induced full-thickness macular holes.

    PubMed

    Qi, Y; Wang, Y; You, Q; Tsai, F; Liu, W

    2017-07-01

    PurposeTo report OCT appearance and surgical outcomes of full-thickness macular holes (MHs) accidentally caused by laser devices.Patients and methodsThis retrospective case series included 11 eyes of 11 patients with laser-induced MHs treated by pars plana vitrectomy, internal limiting membrane (ILM) peeling, and gas or silicone oil tamponade. Evaluations included a full ophthalmic examination, macular spectral-domain optical coherence tomography (SD-OCT), and fundus photography. Main outcome measures is MH closure and final visual acuity; the secondary outcome was the changes of retinal pigment epithelium and photoreceptor layer evaluated by sequential post-operative SD-OCT images.ResultsFive patients were accidentally injured by a yttrium aluminum garnet (YAG) laser and six patients by handheld laser. MH diameters ranged from 272 to 815 μm (mean, 505.5±163.0 μm) preoperatively. Best-corrected visual acuity (BCVA) improved from a mean of 0.90 logMAR (range, counting finger-8/20) preoperatively to a mean of 0.34 logMAR (range, a counting finger-20/20) postoperatively (P=0.001, t=4.521). Seven of 11 patients (63.6%) achieved a BCVA better than 10/20. Ten patients had a subfoveal hyperreflectivity and four patients had a focal choroidal depression subfoveal preoperatively. At the last follow-up, all 11 eyes demonstrated the following: closure of the macular hole, variable degrees of disruption of external limiting membrane (ELM) and outer photoreceptor ellipsoid and interdigitation bands. In 10 eyes, the disruption was in the form of focal defects in the outer retina. After surgery, the subfoveal hyperreflectivity and focal choroidal depression remained.ConclusionAccidental laser-induced full-thickness macular holes can be successfully closed with surgery. Inadvertent retinal injury from laser devices, especially handheld laser injury has occurred with increasing frequency in recent years. However, there is a paucity of data regarding these types of injuries

  19. Evaluation of IMS - Swedish Laser road tester : final report.

    DOT National Transportation Integrated Search

    1990-09-01

    A test of the IMS - Swedish Laser road tester was conducted in September 1988. The vehicle mounted laser equipment was used to survey pavement conditions on sections of Oregon's Interstate and non-interstate highway system. : The IMS laser equipment ...

  20. Evaluation of cystoscopic-guided laser ablation of intramural ectopic ureters in female dogs.

    PubMed

    Berent, Allyson C; Weisse, Chick; Mayhew, Philipp D; Todd, Kimberly; Wright, Monika; Bagley, Demetrius

    2012-03-15

    To describe and evaluate the short- and long-term outcomes in female dogs after cystoscopic-guided laser ablation of ectopic ureters (CLA-EU). Prospective case series. 32 incontinent female dogs with intramural ectopic ureters. A diagnosis of intramural ectopic ureters was made via cystoscopy and fluoroscopy in all patients. Transurethral CLA-EU (via diode laser [n = 27] or Holmium:yttrium aluminum garnet laser [3]) was performed to relocate the ectopic ureteral orifice cranially into the urinary bladder. All vaginal anomalies were treated with the laser concurrently. Follow-up evaluation was standardized and included urinary continence scoring, serial bacteriologic culture of urine samples, and a follow-up cystoscopy 6 to 8 weeks after CLA-EU. Ectopic ureteral orifices of all dogs were initially located in the urethra. Eighteen of 30 dogs had bilateral ectopic ureters, and 12 had unilateral ectopic ureters. All dogs had other concurrent urinary anomalies. At the time of last follow-up (median, 2.7 years after CLA-EU, [range, 12 to 62 months]), 14 of 30 (47%) dogs did not require any additional treatments following CLA-EU to maintain urinary continence. For the 16 residually incontinent dogs, the addition of medical management, transurethral bulking-agent injection, or placement of a hydraulic occluder was effective in 3, 2, and 4 dogs, respectively, improving the overall urinary continence rate to 77% (23/30 dogs). One dog had evidence of polypoid cystitis at the neoureteral orifice 6 weeks after CLA-EU that was resolved at 3 months. CLA-EU provided an effective, safe, and minimally invasive alternative to surgery for intramural ectopic ureters in female dogs.

  1. Implementation Cryptography Data Encryption Standard (DES) and Triple Data Encryption Standard (3DES) Method in Communication System Based Near Field Communication (NFC)

    NASA Astrophysics Data System (ADS)

    Ratnadewi; Pramono Adhie, Roy; Hutama, Yonatan; Saleh Ahmar, A.; Setiawan, M. I.

    2018-01-01

    Cryptography is a method used to create secure communication by manipulating sent messages during the communication occurred so only intended party that can know the content of that messages. Some of the most commonly used cryptography methods to protect sent messages, especially in the form of text, are DES and 3DES cryptography method. This research will explain the DES and 3DES cryptography method and its use for stored data security in smart cards that working in the NFC-based communication system. Several things that will be explained in this research is the ways of working of DES and 3DES cryptography method in doing the protection process of a data and software engineering through the creation of application using C++ programming language to realize and test the performance of DES and 3DES cryptography method in encrypted data writing process to smart cards and decrypted data reading process from smart cards. The execution time of the entering and the reading process data using a smart card DES cryptography method is faster than using 3DES cryptography.

  2. Cracking the perfusion code?: Laser-assisted Indocyanine Green angiography and combined laser Doppler spectrophotometry for intraoperative evaluation of tissue perfusion in autologous breast reconstruction with DIEP or ms-TRAM flaps.

    PubMed

    Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P

    2016-10-01

    The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Evaluation of human papillomavirus elimination from cervix uteri by infrared laser exposure.

    PubMed

    Dymkovets, V P; Ezhov, V V; Manykin, A A; Belov, S V; Danileiko, Yu K; Osiko, V V; Salyuk, V A

    2011-12-01

    Elimination of types 16 and 18 human papilloma virus from the surface of cervix uteri for secondary prevention of cervical cancer was evaluated. The method is protected by patent of invention of the Russian Federation. Infrared laser therapy of cervix uteri was carried out in patients with precancer diseases of cervix uteri at Department of Gynecology of Municipal Clinical Hospital No. 52 (Moscow). Papillomavirus infection was eliminated using a Russian diode laser (lambda=1.06 μ, radiation power 10 W) with a collimating headpiece using carbon die at a distance of 10-12 cm from the exposed surface. The treatment resulted in a high percentage of elimination of types 16 and 18 oncogenic virus 4-6 weeks and during delayed periods after exposure.

  4. Evaluation of Optical Depths and Self-Absorption of Strontium and Aluminum Emission Lines in Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Alfarraj, Bader A; Bhatt, Chet R; Yueh, Fang Yu; Singh, Jagdish P

    2017-04-01

    Laser-induced breakdown spectroscopy (LIBS) is a widely used laser spectroscopic technique in various fields, such as material science, forensic science, biological science, and the chemical and pharmaceutical industries. In most LIBS work, the analysis is performed using radiative transitions from atomic emissions. In this study, the plasma temperature and the product [Formula: see text] (the number density N and the absorption path length [Formula: see text]) were determined to evaluate the optical depths and the self-absorption of Sr and Al lines. A binary mixture of strontium nitrate and aluminum oxide was used as a sample, consisting of variety of different concentrations in powder form. Laser-induced breakdown spectroscopy spectra were collected by varying various parameters, such as laser energy, gate delay time, and gate width time to optimize the LIBS signals. Atomic emission from Sr and Al lines, as observed in the LIBS spectra of different sample compositions, was used to characterize the laser induced plasma and evaluate the optical depths and self-absorption of LIBS.

  5. Evaluation of thermal effects on the beam quality of disk laser with unstable resonator

    NASA Astrophysics Data System (ADS)

    Shayganmanesh, Mahdi; Beirami, Reza

    2017-01-01

    In this paper thermal effects of the disk active medium and associated effects on the beam quality of laser are investigated. Using Collins integral and iterative method, transverse mode of an unstable resonator including a Yb:YAG active medium in disk geometry is calculated. After that the beam quality of the laser is calculated based on the generalized beam characterization method. Thermal lensing of the disk is calculated based on the OPD (Optical Path Difference) concept. Five factors influencing the OPD including temperature gradient, disk thermal expansion, photo-elastic effect, electronic lens and disk deformation are considered in our calculations. The calculations show that the effect of disk deformation factor on the quality of laser beam in the resonator is strong. However the total effect of all the thermal factors on the internal beam quality is fewer. Also it is shown that thermal effects degrade the output power, beam profile and beam quality of the output laser beam severely. As well the magnitude of each of affecting factors is evaluated distinctly.

  6. Processes for Assessing Outcomes of Multi-national Missions (Processus d’evaluation des resultats de missions multinationales)

    DTIC Science & Technology

    2013-11-01

    la raison d’être du recueil des données relatives aux variables centrales afin de soutenir ces efforts dans...communs utilisés par les pays membres et un ensemble central d’indicateurs complétant les Mesures de Performance (MOP) et Mesures d’Efficacité (MOE...dénomination « STO », « RTO » ou « AGARD » selon le cas, suivi du numéro de série. Des informations analogues, telles que le titre est la date de

  7. Use of the erbium, chromium:yttrium-scandium-gallium-garnet laser on human enamel tissues. Influence of the air-water spray on the laser-tissue interaction: scanning electron microscope evaluations.

    PubMed

    Olivi, Giovanni; Angiero, Francesca; Benedicenti, Stefano; Iaria, Giuseppe; Signore, Antonio; Kaitsas, Vassilios

    2010-11-01

    The study investigated the influence of varying amounts of air/water spray and the energy used by an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) 2,780 nm laser when treating dental tissues. The morphological effects produced by the laser interaction on healthy human enamel were evaluated by scanning electron microscopy (SEM). The vestibular and lingual surfaces of ten molars were treated with laser at different power settings; each surface was subdivided into cervical, median, and occlusal parts and treated with different proportions of water spray; the series contained 60 tooth portions. Treatment differed in terms of power setting and air/water percentage. All specimens were then subjected to dehydration and metallisation. At SEM evaluation, the classic aspect of laser-treated enamel was visible: grooves, flakes, shelves and sharp edges, indicative of micro-explosion rather than melting. Vaporisation of the tissue created a clear delimitation from surrounding healthy tissue, with partial respect to the prismatic structure of the treated enamel. The aspect of the enamel was rarely type 1 Silverstone but more frequently type 2 or 3, with prismatic structure not respected and/or completely disordered. These morphological differences appeared to be correlated with the inclination of the laser beam aimed at the enamel prisms and with the percentage of air/water used. The laser system analysed showed itself to be effective at removing human dental enamel. The results appeared to be closely correlated with the variation of the percentage of the laser's water-air spray.

  8. Relations de Dispersion et Diffusion des Glueballs et des Mesons dans la Theorie de Jauge U(1)(2+1) Compacte

    NASA Astrophysics Data System (ADS)

    Ahmed, Chaara El Mouez

    Nous avons etudie les relations de dispersion et la diffusion des glueballs et des mesons dans le modele U(1)_{2+1} compact. Ce modele a ete souvent utilise comme un simple modele de la chromodynamique quantique (QCD), parce qu'il possede le confinement ainsi que les etats de glueballs. Par contre, sa structure mathematique est beaucoup plus simple que la QCD. Notre methode consiste a diagonaliser l'Hamiltonien de ce modele dans une base appropriee de graphes et sur reseau impulsion, afin de generer les relations de dispersion des glueballs et des mesons. Pour la diffusion, nous avons utilise la methode dependante du temps pour calculer la matrice S et la section efficace de diffusion des glueballs et des mesons. Les divers resultats obtenus semblent etre en accord avec les travaux anterieurs de Hakim, Alessandrini et al., Irving et al., qui eux, utilisent plutot la theorie des perturbations en couplage fort, et travaillent sur un reseau espace-temps.

  9. In-Flight Performance of the Mercury Laser Altimeter Laser Transmitter

    NASA Technical Reports Server (NTRS)

    Yu, Anthony W.; Sun, Xiaoli; Li, Steven X.; Cavanaugh, John F.; Neumann, Gregory A.

    2014-01-01

    The Mercury Laser Altimeter (MLA) is one of the payload instruments on the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft, which was launched on August 3, 2004. MLA maps Mercury's shape and topographic landforms and other surface characteristics using a diode-pumped solid-state laser transmitter and a silicon avalanche photodiode receiver that measures the round-trip time of individual laser pulses. The laser transmitter has been operating nominally during planetary flyby measurements and in orbit about Mercury since March 2011. In this paper, we review the MLA laser transmitter telemetry data and evaluate the performance of solid-state lasers under extended operation in a space environment.

  10. Identification et prise en charge des femmes ayant des antécédents familiaux de cancer du sein

    PubMed Central

    Heisey, Ruth; Carroll, June C.

    2016-01-01

    Résumé Objectif Résumer les meilleures données portant sur les stratégies d’identification et de prise en charge des femmes qui présentent des antécédents familiaux de cancer du sein. Sources d’information Une recherche a été effectuée sur PubMed à l’aide des mots-clés anglais suivants : breast cancer, guidelines, risk, family history, management et magnetic resonance imaging screening, entre 2000 et 2016. La plupart des données sont de niveau II. Message principal Une bonne anamnèse familiale est essentielle lors de l’évaluation du risque de cancer du sein afin d’identifier les femmes qui sont candidates à une recommandation en counseling génétique pour un éventuel test génétique. On peut sauver des vies en offrant aux femmes porteuses d’une mutation au gène BRCA des interventions chirurgicales de réduction des risques (mastectomie bilatérale prophylactique, salpingo-ovariectomie bilatérale). Il faut encourager toutes les femmes qui présentent des antécédents familiaux de cancer du sein à demeurer actives et à limiter leur consommation d’alcool à moins de 1 verre par jour; certaines femmes sont admissibles à la chimioprévention. Il faut offrir aux femmes dont le risque à vie de cancer du sein est de 20 à 25 % ou plus un dépistage poussé par imagerie par résonance magnétique en plus d’une mammographie. Conclusion Une vie saine et la chimioprévention (chez les candidates) pourraient réduire l’incidence du cancer du sein; le dépistage poussé pourrait entraîner une détection plus précoce. Le fait d’aiguiller des femmes porteuses d’une mutation au BRCA vers la chirurgie de réduction des risques sauve des vies. PMID:27737991

  11. Evaluation of enamel surface modification using PS-OCT after laser treatment to increase resistance to demineralization

    NASA Astrophysics Data System (ADS)

    Kim, Jin Wan; Chan, Kenneth H.; Fried, Daniel

    2016-02-01

    At laser intensities below ablation, carbonated hydroxyapatite in enamel is converted into a purer phase hydroxyapatite with increased acid resistance. Previous studies suggested the possibility of achieving the conversion without surface modification. This study attempts to evaluate the thresholds for the modification without additional changes in physical and optical properties of the enamel. Bovine specimens were irradiated using an RF-excited CO2 laser operating at 9.4-μm with a pulse duration of 26- μs, pulse repetition rates of 100-1000 Hz, with a Gaussian spatial beam profile - 1.4 mm in diameter. After laser treatment, the samples were subjected to acid demineralization for 48 hours to simulate acidic intraoral conditions of a caries attack. The resulting demineralization and erosion were assessed using polarization sensitive OCT (PS-OCT) and 3D digital microscopy. The images from digital microscopy demonstrated a clear delineation between laser protected zones without visual changes and zones with higher levels of demineralization and erosion. Distinct changes in the surface morphology were found within the laser treated area in accordance with the Gaussian spatial beam profile. There was significant protection from the laser in areas that were not visually altered.

  12. Note des Éditeurs scientifiques

    NASA Astrophysics Data System (ADS)

    Averbuch, P.

    Cette série d'articles est une revue de résultats expérimentaux sur différents "fluides" moléculaires, dans lesquels la cohésion est due à des forces de Van der Waals et à des liaisons hydrogène, l'eau étant un de ces fluides. Ces résultats sont présentés de façon à justifier expérimentalement un modèle original, non extensif, des propriétés de ces fluides, et l'ensemble se présente sous la forme de trois articles décrivant le modèle, suivis chacun par un article le comparant aux résultats expérimentaux publiés par de nombreux auteurs. Le caractère non extensif des propriétés physiques des fluides est choquant, contraire à beaucoup d'idées établies, il semble n'avoir en sa faveur qu'un argument, la comparaison avec un nombre de résultats expérimentaux assez grand pour que l'effet du hasard soit difficilement soupçonnable. En particulier, les écarts entre des résultats de mesures faits par des auteurs différents dans des conditions différentes sont expliqués, le sérieux et la compétence des différents expérimentateurs ne sont plus mis en doute : mais l'interprétation de ces résultats avec un modèle extensif non adapté est seule mise en cause. Les modèles extensifs étant utilisés systématiquement, au delà des expériences de physiciens, dans les calculs d'ingénieurs, et dans la modélisation d'appareils qui fonctionnent et de phénomènes naturels observés par tout le monde, il fallait expliquer pourquoi on pouvait renoncer à l'extensivité. Les raisons du succès pratique des modèles extensifs sont données, d'abord dans le cas des nématiques, puis dans celui des liquides ordinaires, et c'est ce qui rend l'ensemble cohérent, tant avec les mesures physiques fines qu'avec les observations quotidiennes. Il n'en reste pas moins que si l'interprétation donnée dans cette série d'articles est généralisable, une justification théorique du modèle utilisé devient nécessaire. Pour ce qui est des propriétés d

  13. Applications of Composite Materials in Helicopter Construction (Les Applications des Materiaux Composite dans la Construction des Helicopteres),

    DTIC Science & Technology

    1983-11-21

    TRANSLATION TITLE: APPLICATIONS OF COMPOSITE MATERIALS IN HELICOPTER CONSTRUCTION LES APPLICATIONS DES MATERTAUX COMWSITE DANS LA CONSTRUCTION DES...International Symposium on Design and Use of Kevlar in Aircraft, Geneva, 12 October 1982 [Beziac, Gilbert;* Les applications des mat6riaux composite...the pilot’s orders to the engine and the rotors. --Rear rotor Conventional or "faired propeller" type with its overall pitch control --Vibration

  14. Evaluation of Patient Perceptions After Vestibuloplasty Procedure: A Comparison of Diode Laser and Scalpel Techniques

    PubMed Central

    Farista, Sana; Koppolu, Pradeep; Baroudi, Kusai; Uppada, Udaykiran; Mishra, Ashank; Savarimath, Abhishek; Lingam, Amara Swapna

    2016-01-01

    Introduction Inadequate vestibular depth results in poor plaque control owing to an insufficient width of keratinized gingiva. Vestibuloplasty provides the necessary vestibular depth and can be performed either with a scalpel, electrocautery or lasers. Aim To evaluate the patient perceptions related to pain and discomfort on the 1st, 3rd and the 7th day post vestibuloplasty and also assess the healing outcomes related to the treatment of inadequate vestibular depth either with the diode laser or the scalpel. Materials and Methods Twenty patients who had inadequate vestibular depth and required vestibuloplasty were assigned randomly to undergo the procedure either with the scalpel or the laser. The data obtained was analysed for intergroup comparison with an independent paired t-test and intragroup comparison was determined by a paired t-test. Results Intragroup comparison within the laser group for VAS scores of pain and discomfort within all the reported days exhibited a significant difference (p<0.05). Inter group comparison revealed that the patients in the laser group had lower VAS cores for pain and discomfort compared to the scalpel group (p<0.05). Analysis of the three pointer scale for healing revealed that the patients in the laser group exhibited better healing outcomes on the 1st, 3rd and the 7th day compared to the scalpel group. Conclusion Observations from the study highlight the opinion that laser can be a safe and effective alternative to traditional vestibuloplasty performed with the scalpel. PMID:27437370

  15. Evaluation of Laser Stabilization and Imaging Systems for LCLS-II - Final Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barry, Matthew

    2015-08-20

    By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performancesmore » when tested over fifteen hours, Guidestar-II kept the beam stable over approximately 70-110um while the MRC system kept it stable over approximately 90-100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (less than 10 minutes) without the assistance of a stability system, approximately 55um compared to approximately 70um, but the four lens configurations beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.« less

  16. Computed-tomographic and conventional linear-tomographic evaluation of tracheobronchial lesions for laser photoresection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearlberg, J.L.; Sandler, M.A.; Kvale, P.

    1985-03-01

    Laser therapy is a new modality for treatment of airway lesions. The authors examined 18 patients prior to laser photoresection of tracheobronchial lesions. Thirteen had cancers involving the distal trachea, carina, and/or proximal bronchi; five had benign lesions of the middle or proximal trachea. Each patient was examined by conventional linear tomography (CLT) and computed tomography (CT). CT was valuable in patients who had lesions of the distal trachea, carina, and/or proximal bronchi. Its particular usefulness, and its advantage relative to CLT, consisted in its ability to delineate vascular structures adjacent to the planned area of photoresection. Neither CLT normore » CT was helpful in evaluation of benign lesions of the proximal trachea.« less

  17. Etude spectroscopique des collisions moleculaires (hydrogene-azote et hydrogene-oxygene) a des energies de quelques MeV

    NASA Astrophysics Data System (ADS)

    Plante, Jacinthe

    1998-09-01

    Les resultats presentes ici proviennent d'une etude systematique portant sur les collisions a vitesse constante, entre les projectiles d'hydrogene (H+, H2+ et H3+ a 1 MeV/nucleon) et deux cibles gazeuses (N2 et O2), soumises a differentes pressions. Les collisions sont analysees a l'aide des spectres d'emission (de 400 A a 6650 A) et des graphiques intensite/pression. Les spectres ont revele la presence des raies d'azote atomique, d'azote moleculaire, d'oxygene atomique, d'oxygene moleculaire et d'hydrogene atomique. Les raies d'hydrogene sont observees seulement avec les projectiles H2+ et H3+. Donc les processus responsables de la formation de ces raies sont des mecanismes de fragmentation des projectiles. Pour conclure, il existe une difference notable entre les projectiles et les differentes pressions. Les raies d'azote et d'oxygene augmentent selon la pression et les raies d'hydrogene atomique presentent une relation non lineaire avec la pression.

  18. Laser safety eyewear.

    PubMed

    1993-04-01

    In spite of repeated warnings about laser safety practices, as well as the availability of laser safety eyewear (LSE), eye injuries continue to occur during use of surgical lasers, as discussed in the Clinical Perspective, "Laser Energy and Its Dangers to Eyes," preceding this Evaluation. We evaluated 48 models of LSE, including goggles, spectacles, and wraps, from 11 manufacturers. The evaluated models are designed with absorptive lenses that provide protection from CO2 (carbon dioxide), Nd:YAG (neodymium:yttrium-aluminum-garnet), and 532 (frequency-doubled Nd:YAG) surgical laser wavelengths; several models provide multiwavelength protection. (Refer to ECRI's Product Comparison System report on LSE for specifications of other models.) Although most of the evaluated models can adequately protect users from laser energy--provided that the eyewear is used--many models of LSE, especially goggles, are designed with little regard for the needs of actual use (e.g., adequate labeling, no alteration of color perception, sufficient field of vision [FOV], comfort). Because these factors can discourage people from using LSE, we encourage manufacturers to develop new and improved models that will be worn. We based our ratings primarily on the laser protection provided by the optical density (OD) of the lenses; we acknowledge the contribution of Montana Laser Optics Inc., of Bozeman, Montana, in performing our OD testing. We also considered actual-use factors, such as those mentioned above, to be significant. Among the models rated Acceptable is one whose labeled OD is lower than the level we determined to be adequate for use during most laser surgery; however, this model offers protection under specific conditions of use (e.g., for use by spectators some distance from the surgical site, for use during endoscopic procedures) that should be determined by the laser safety officer (LSO). LSE that would put the wearer at risk are rated Unacceptable (e.g., some models are not

  19. Bond strengths evaluation of laser ceramic bracket debonding

    NASA Astrophysics Data System (ADS)

    Dostalová, T.; Jelinková, H.; Šulc, J.; Němec, M.; Fibrich, M.; Jelínek, M.; Michalík, P.; Bučková, M.

    2012-09-01

    Ceramic brackets often used for an orthodontic treatment can lead to problems such as enamel tear outs because of their low fracture resistance and high bond strengths. Therefore the aim of our study was to investigate the positive laser radiation effect on bracket debonding. Moreover, the influence of the enamel shape surface under the bracket and laser radiation power on the debonding strength was investigated. The source of the radiation was the longitudinally diode-pumped Tm:YAP laser operating at 1997 nm. To eliminate the tooth surface roughness the flat enamel surface was prepared artificially and the bracket was bonded on it. The debonding was accomplished by Tm:YAP laser radiation with different the power value while recording the temperature rise in the pulp. To simulate the debonding process in vivo the actual bond strength was measured by the digital force gauge. The results were analyzed by scanning electron microscope.

  20. DES Science Portal: II- Creating Science-Ready Catalogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fausti Neto, Angelo; et al.

    We present a novel approach for creating science-ready catalogs through a software infrastructure developed for the Dark Energy Survey (DES). We integrate the data products released by the DES Data Management and additional products created by the DES collaboration in an environment known as DES Science Portal. Each step involved in the creation of a science-ready catalog is recorded in a relational database and can be recovered at any time. We describe how the DES Science Portal automates the creation and characterization of lightweight catalogs for DES Year 1 Annual Release, and show its flexibility in creating multiple catalogs withmore » different inputs and configurations. Finally, we discuss the advantages of this infrastructure for large surveys such as DES and the Large Synoptic Survey Telescope. The capability of creating science-ready catalogs efficiently and with full control of the inputs and configurations used is an important asset for supporting science analysis using data from large astronomical surveys.« less

  1. Evaluation of the Diode laser (810nm, 980 nm) on color change of teeth after external bleaching.

    PubMed

    Kiomars, Nazanin; Azarpour, Pouneh; Mirzaei, Mansooreh; Hashemi Kamangar, Sedighe Sadat; Kharazifard, Mohammad Javad; Chiniforush, Nasim

    2016-12-30

    Subject and aim: The aim of this study was to evaluate the efficiency of diode laser-activated bleaching systems for color change of teeth. Materials & Methods: 40 premolars with intact enamel surfaces were selected for five external bleaching protocols (n=8). Two different wavelengths of diode laser (810 and 980 nm) with two different hydrogen peroxide concentrations (30% and 46%) were selected for laser bleaching. Group 1 received bleaching (Heydent- Germany) with a 810 nm diode laser; Group 2 received bleaching (Heydent- Germany) with a 980 nm diode laser; Group 3 received bleaching (laser white*20- Biolase) with a 810 nm diode laser; Group 4 received bleaching (laser white*20- Biolase) with a 980 nm diode laser, with an output power of 1.5 W, in continuous wave (cw) mode for each irradiation. Group 5 as control group received 40% hydrogen peroxide (Opalescence Boost, Ultradent-USA) with no light activation. The color of teeth was scored at baseline and 1 week after bleaching with spectrophotometer. Color change data on the CIEL*a*b* system were analyzed statistically by the one-way ANOVA and Tukey's HSD test. Results: All the bleaching techniques resulted in shade change. According to ΔE values, all techniques were effective to bleach the teeth (ΔE ≥ 3). Statistically significant differences were detected among bleaching protocols (p=0.06). Regarding shade change values expressed as ΔL*, Δa*, Δb*, ΔE*, laser bleached groups were no statistically different with each other (p>0.05). Conclusion: Bleaching with different wavelengths of diode laser resulted in the same results.

  2. Evaluation of anodic behavior of commercially pure titanium in tungsten inert gas and laser welds.

    PubMed

    Orsi, Iara Augusta; Raimundo, Larica B; Bezzon, Osvaldo Luiz; Nóbilo, Mauro Antonio de Arruda; Kuri, Sebastião E; Rovere, Carlos Alberto D; Pagnano, Valeria Oliveira

    2011-12-01

    This study evaluated the resistance to corrosion in welds made with Tungsten Inert Gas (TIG) in specimens made of commercially pure titanium (cp Ti) in comparison with laser welds. A total of 15 circular specimens (10-mm diameter, 2-mm thick) were fabricated and divided into two groups: control group-cp Ti specimens (n = 5); experimental group-cp Ti specimens welded with TIG (n = 5) and with laser (n = 5). They were polished mechanically, washed with isopropyl alcohol, and dried with a drier. In the anodic potentiodynamic polarization assay, measurements were taken using a potentiostat/galvanostat in addition to CorrWare software for data acquisition and CorrView for data visualization and treatment. Three curves were made for each working electrode. Corrosion potential values were statistically analyzed by the Student's t-test. Statistical analysis showed that corrosion potentials and passive current densities of specimens welded with TIG are similar to those of the control group, and had lower values than laser welding. TIG welding provided higher resistance to corrosion than laser welding. Control specimens welded with TIG were more resistant to local corrosion initiation and propagation than those with laser welding, indicating a higher rate of formation and growth of passive film thickness on the surfaces of these alloys than on specimens welded with laser, making it more difficult for corrosion to occur. © 2011 by the American College of Prosthodontists.

  3. Welding induced residual stress evaluation using laser-generated Rayleigh waves

    NASA Astrophysics Data System (ADS)

    Ye, Chong; Zhou, Yuanlai; Reddy, Vishnu V. B.; Mebane, Aaron; Ume, I. Charles

    2018-04-01

    Welding induced residual stress could affect the dimensional stability, fatigue life, and chemical resistance of the weld joints. Ultrasonic method serves as an important non-destructive tool for the residual stress evaluation due to its easy implementation, low cost and wide application to different materials. Residual stress would result in the ultrasonic wave velocity variation, which is the so called acoustoelastic effect. In this paper, Laser/EMAT ultrasonic technique was proposed to experimentally study the relative velocity variation ΔV/V of Rayleigh wave, which has the potential to evaluate surface/subsurface longitudinal residual stress developed during the Gas Metal Arc Welding process. Broad band ultrasonic waves were excited by pulsed Q-Switched Nd: YAG laser. An electromagnetic acoustic transducer (EMAT) attached to the welded plates was used to capture the Rayleigh wave signals propagating along the weld seam direction. Different time of flight measurements were conducted by varying the distance between the weld seam and Rayleigh wave propagating path in the range of 0 to 45 mm. The maximum relative velocity difference was found on the weld seam. With the increasing distance away from the weld seam, the relative velocity difference sharply decreased to negative value. With further increase in distance, the relative velocity difference slowly increased and approached zero. The distribution of relative velocity variations indicates that tensile stress appears in the melted zone as it becomes compressive near the heat-affected zone.

  4. Using the verona coding definitions of emotional sequences (VR-CoDES) and health provider responses (VR-CoDES-P) in the dental context.

    PubMed

    Wright, Alice; Humphris, Gerry; Wanyonyi, Kristina L; Freeman, Ruth

    2012-10-01

    To show if cues, concerns and provider responses (defined in VR-CoDES and VR-CoDES-P manuals) are present, can be reliably coded and require additional advice for adoption in a dental context. Thirteen patients in a dental practice setting were videoed with either their dentist or hygienist and dental nurse present in routine treatment sessions. All utterances were coded using the Verona systems: VR-CoDES and the VR-CoDES-P. Rates of cue, concerns and provider responses described and reliability tested. The VR-CoDES and VR-CoDES-P were successfully applied in the dental context. The intra-rater ICCs for the detection of cues and concerns and provider response were acceptable and above 0.75. A similar satisfactory result was found for the inter-rater reliability. The VR-CoDES and the VR-CoDES-P are applicable in the dental setting with minor supporting guidelines and show evidence of reliable coding. The VR-CoDES and the VR-CoDES-P may be helpful tools for analysing patient cues and concerns and the dental professionals' responses in the dental context. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Evaluation of hollow fiberoptic tips for the conduction of Er:YAG laser.

    PubMed

    Alves, Paulo Roberto Vieira; Aranha, Norberto; Alfredo, Edson; Marchesan, Melissa Andréia; Brugnera Junior, Aldo; Sousa-Neto, Manoel D

    2005-08-01

    The use of Er:YAG laser operating in the 3 microm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (lambda = 2.94 microm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission.

  6. Evaluation of laser ablation microtomy for correlative microscopy of hard tissues.

    PubMed

    Boyde, A

    2018-02-27

    Laser ablation machining or microtomy (LAM) is a relatively new approach to producing slide mounted sections of translucent materials. We evaluated the method with a variety of problems from the bone, joint and dental tissues fields where we require thin undecalcified and undistorted sections for correlative light microscopy (LM) and backscattered electron scanning electron microscopy (BSE SEM). All samples were embedded in poly-methylmethacrlate (PMMA) and flat block surfaces had been previously studied by BSE-SEM and confocal scanning light microscopy (CSLM). Most were also studied by X-yay microtomography (XMT). The block surface is stuck to a glass slide with cyanoacrylate adhesive. Setting the section thickness and levelling uses inbuilt optical coherence tomographic imaging. Tight focusing of near-infrared laser radiation in the sectioning plane gives extreme intensities causing photodisruption of material at the focal point. The laser beam is moved by a fast scanner to write a cutting line, which is simultaneously moved by an XY positioning unit to create a sectioning plane. The block is thereby released from the slide, leaving the section stuck to the slide. Light, wet polishing on the finest grade (4000 grit) silicon carbide polishing paper is used to remove a 1-2 μm thick damaged layer at the surface of the section. Sections produced by laser cutting are fine in quality and superior to those produced by mechanical cutting and can be thinner than the 'voxel' in most laboratory X-ray microtomography systems. The present extensive pilot studies have shown that it works to produce samples which we can study by both light and electron microscopy. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

  7. Reticulation des fibres lignocellulosiques

    NASA Astrophysics Data System (ADS)

    Landrevy, Christel

    Pour faire face à la crise économique la conception de papier à valeur ajoutée est développée par les industries papetières. Le but de se projet est l'amélioration des techniques actuelles de réticulation des fibres lignocellulosiques de la pâte à papier visant à produire un papier plus résistant. En effet, lors des réactions de réticulation traditionnelles, de nombreuses liaisons intra-fibres se forment ce qui affecte négativement l'amélioration anticipée des propriétés physiques du papier ou du matériau produit. Pour éviter la formation de ces liaisons intra-fibres, un greffage sur les fibres de groupements ne pouvant pas réagir entre eux est nécessaire. La réticulation des fibres par une réaction de « click chemistry » appelée cycloaddition de Huisgen entre un azide et un alcyne vrai, catalysée par du cuivre (CuAAC) a été l'une des solutions trouvée pour remédier à ce problème. De plus, une adaptation de cette réaction en milieux aqueux pourrait favoriser son utilisation en milieu industriel. L'étude que nous désirons entreprendre lors de ce projet vise à optimiser la réaction de CuAAC et les réactions intermédiaires (propargylation, tosylation et azidation) sur la pâte kraft, en milieu aqueux. Pour cela, les réactions ont été adaptées en milieu aqueux sur la cellulose microcristalline afin de vérifier sa faisabilité, puis transférée à la pâte kraft et l'influence de différents paramètres comme le temps de réaction ou la quantité de réactifs utilisée a été étudiée. Dans un second temps, une étude des différentes propriétés conférées au papier par les réactions a été réalisée à partir d'une série de tests papetiers optiques et physiques. Mots Clés Click chemistry, Huisgen, CuAAC, propargylation, tosylation, azidation, cellulose, pâte kraft, milieu aqueux, papier.

  8. Evaluating the use of laser radiation in cleaning of copper embroidery threads on archaeological Egyptian textiles

    NASA Astrophysics Data System (ADS)

    Abdel-Kareem, Omar; Harith, M. A.

    2008-07-01

    Cleaning of copper embroidery threads on archaeological textiles is still a complicated conservation process, as most textile conservators believe that the advantages of using traditional cleaning techniques are less than their disadvantages. In this study, the uses of laser cleaning method and two modified recipes of wet cleaning methods were evaluated for cleaning of the corroded archaeological Egyptian copper embroidery threads on an archaeological Egyptian textile fabric. Some corroded copper thread samples were cleaned using modified recipes of wet cleaning method; other corroded copper thread samples were cleaned with Q-switched Nd:YAG laser radiation of wavelength 532 nm. All tested metal thread samples before and after cleaning were investigated using a light microscope and a scanning electron microscope with an energy dispersive X-ray analysis unit. Also the laser-induced breakdown spectroscopy (LIBS) technique was used for the elemental analysis of laser-cleaned samples to follow up the laser cleaning procedure. The results show that laser cleaning is the most effective method among all tested methods in the cleaning of corroded copper threads. It can be used safely in removing the corrosion products without any damage to both metal strips and fibrous core. The tested laser cleaning technique has solved the problems caused by other traditional cleaning techniques that are commonly used in the cleaning of metal threads on museum textiles.

  9. Evaluation of Contemporary Holmium Laser Fibers for Performance Characteristics.

    PubMed

    Lusch, Achim; Heidari, Emon; Okhunov, Zhamshid; Osann, Kathryn; Landman, Jaime

    2016-05-01

    Several holmium:YAG laser fibers for urologic applications are currently commercially available. We compared contemporary holmium laser fibers with different core sizes for performance characteristics, including energy transmission, fiber failure, fiber flexibility, and core diameter. Single-use fibers from Cook, Boston Scientific, and Storz were tested in small (200 and 272/273 μm), medium (365 μm), and large (550 and 940/1000 μm) core sizes. Fibers were tested in straight and deflected configurations. All fibers were evaluated for flexibility, true fiber diameter, energy transmission, and fiber failure. For energy transmission, fibers were tested at a pulse energy of 1 J and a frequency of 10 Hz for 30 seconds. All tests were performed on a 30 W holmium laser. For the small core fibers, Storz, Cook OptiLite, and Smart Sync had the smallest core diameter (p < 0.005). In the large core group, Cook OptiLite and Boston Scientific AccuMax showed the smallest diameter. Among the small core fibers, Storz and Cook Smart Sync showed a significant higher deflection, whereas in the 550 μm group, Boston Scientific AccuMax and Cook Smart Sync were the most flexible fibers. In the large and medium core groups, Boston Scientific AccuMax showed superior energy transmission (p = 0.007 and p = 0.001, respectively), whereas in the small core group, there was no significant difference between the fibers, except for 272/3 μm (Storz was inferior compared with the competitors [p < 0.0005]). For fiber failure, Storz, Cook OptiLite, and BS AccuTrac completed all testing without failing (200 μm, bending radius <0.5 cm). In the 365 μm group, Cook OptiLite showed superior results, whereas in the large core group, Boston Scientific AccuMax was superior. Performance characteristics differ significantly between different laser fiber diameters and manufacturers, and fiber choice should depend on specific surgical requirements. There is a trend for less

  10. Experimental evaluation of a new system for laser tissue welding applied on damaged lungs.

    PubMed

    Schiavon, Marco; Marulli, Giuseppe; Zuin, Andrea; Lunardi, Francesca; Villoresi, Paolo; Bonora, Stefano; Calabrese, Fiorella; Rea, Federico

    2013-05-01

    Alveolar air leaks represent a challenging problem in thoracic surgery, leading to increased patient morbidity and prolonged hospitalization. Several methods have been used, but no ideal technique exists yet. We investigated the lung-sealing capacity of an experimental kit for laser tissue welding. The kit is composed of a semiconductor laser system applied on a protein substrate associated with a chromophore that increases absorption. In vitro tests on porcine lung tissue were done to define ideal laser parameters (power 100 Å, frequency 50 Hz, pulse duration 400 µs) and protein substrate dilution (50%). For in vivo tests, through a left thoracotomy, 14 pigs received two different lung damages: a linear incision and a circular incision. Protein substrate applied on damaged areas was treated with laser to obtain a layer that reconstituted the integrity of the visceral pleura. Air leaks were intraoperatively evaluated by water submersion test with an airway pressure of 20 cmH2O. Animals were sacrificed at postoperative days 0 and 7 to study early and late pathological features. After applying laser treatment, no air leaks were seen in all proofs except in 2 cases in which a second application was required. At time 0, pathological damage mostly consisted of superficial alveolar necrotic tissue covered by protein membrane. At time 7, a complete recovery of lung lesions by fibrous scar with slight inflammatory reaction of adjacent lung tissue was seen. This experimental study demonstrated the effectiveness of laser tissue welding applied to seal air leaks after lung surgery. Further studies are needed to verify acceptability for human application.

  11. Cell damage evaluation of mammalian cells in cell manipulation by amplified femtosecond ytterbium laser

    NASA Astrophysics Data System (ADS)

    Hong, Z.-Y.; Iino, T.; Hagihara, H.; Maeno, T.; Okano, K.; Yasukuni, R.; Hosokawa, Y.

    2018-03-01

    A micrometer-scale explosion with cavitation bubble generation is induced by focusing a femtosecond laser in an aqueous solution. We have proposed to apply the explosion as an impulsive force to manipulate mammalian cells especially in microfluidic chip. Herein, we employed an amplified femtosecond ytterbium laser as an excitation source for the explosion and evaluated cell damage in the manipulation process to clarify the application potential. The damage of C2C12 myoblast cell prepared as a representative mammalian cell was investigated as a function of distance between cell and laser focal point. Although the cell received strong damage on the direct laser irradiation condition, the damage sharply decreased with increasing distance. Since the threshold distance, above which the cell had no damage, was consistent with radius of the cavitation bubble, impact of the cavitation bubble would be a critical factor for the cell damage. The damage had strong nonlinearity in the pulse energy dependence. On the other hand, cell position shift by the impact of the cavitation bubble was almost proportional to the pulse energy. In balance between the cell viability and the cell position shift, we elucidated controllability of the cell manipulation in microfluidic chip.

  12. Diode laser-induced tissue effects: in vitro tissue model study and in vivo evaluation of wound healing following non-contact application.

    PubMed

    Havel, Miriam; Betz, Christian S; Leunig, Andreas; Sroka, Ronald

    2014-08-01

    The basic difference between the various common medical laser systems is the wavelength of the emitted light, leading to altered light-tissue interactions due to the optical parameters of the tissue. This study examines laser induced tissue effects in an in vitro tissue model using 1,470 nm diode laser compared to our standard practice for endonasal applications (940 nm diode laser) under standardised and reproducible conditions. Additionally, in vivo induced tissue effects following non-contact application with focus on mucosal healing were investigated in a controlled intra-individual design in patients treated for hypertrophy of nasal turbinate. A certified diode laser system emitting the light of λ = 1470 nm was evaluated with regards to its tissue effects (ablation, coagulation) in an in vitro setup on porcine liver and turkey muscle tissue model. To achieve comparable macroscopic tissue effects the laser fibres (600 µm core diameter) were fixed to a computer controlled stepper motor and the laser light was applied in a reproducible procedure under constant conditions. For the in vivo evaluation, 20 patients with nasal obstruction due to hyperplasia of inferior nasal turbinates were included in this prospective randomised double-blinded comparative trial. The endoscopic controlled endonasal application of λ = 1470 nm on the one and λ = 940 nm on the other side, both in 'non-contact' mode, was carried out as an outpatient procedure under local anaesthesia. The postoperative wound healing process (mucosal swelling, scab formation, bleeding, infection) was endoscopically documented and assessed by an independent physician. In the experimental setup, the 1,470 nm laser diode system proved to be efficient in inducing tissue effects in non-contact mode with a reduced energy factor of 5-10 for highly perfused liver tissue to 10-20 for muscle tissue as compared to the 940 nm diode laser system. In the in vivo evaluation scab formation

  13. Dosimetry of laser emission

    NASA Astrophysics Data System (ADS)

    Kirillov, A. I.; Morskov, V. F.; Ustinov, N. D.

    The basic criteria for dosimetric standards on photon, microwave, and ultraviolet emissions are reviewed. Attention is given to the biophysical effects of laser radiation, approaches to the evaluation of optical radiation hazard, and the effect of laser beams on the human eye. The fundamentals of the optical design of dosimeters are discussed, and an eye model is developed for a laser radiation meter. The discussion also covers the design of the electronic circuit of dosimeters and an evaluation of measurement errors.

  14. Minimisation des inductances propres des condensateurs à film métallisé

    NASA Astrophysics Data System (ADS)

    Joubert, Ch.; Rojat, G.; Béroual, A.

    1995-07-01

    In this article, we examine the different factors responsible for the equivalent series inductance in metallized capacitors and we propose structures for capacitors that reduce this inductance. After recalling the structure of metallized capacitors we compare, by experimental measurements, the inductance due to the winding and that one added by the connections. The latter can become preponderant. In order to explain the experimental evolution of the winding impedance vs. frequency, we describe an analytical model which gives the current density in the winding and its impedance. This model enables us to determine the self resonant frequency for different types of capacitors. From where, we can infer the influence of the height of capacitors and their internal and external radius upon performances, It appears that to reduce the equivalent series inductance, it is better to use flat windings and annular windings. Dans cet article nous examinons les différents facteurs responsables de l'inductance équivalente série dans les condensateurs à film métallisé et proposons des géométries de condensateurs qui réduisent cette inductance. Après avoir rappelé la structure des condensateurs à film métallisé, nous comparons, par des mesures expérimentales, l'inductance due au bobinage et l'inductance ajoutée par les connexions. Cette dernière peut devenir prépondérante. Afin d'expliquer l'évolution de l'impédance du bobinage en fonction de la fréquence, nous décrivons un modèle analytique qui donne la densité du courant dans le bobinage et l'impédance de ce dernier. En outre, ce modèle permet de déterminer la fréquence de résonance série de divers types de condensateurs ce qui permet de déduire l'influence de la hauteur des condensateurs et de leurs rayons interne et externe sur les performances. Il apparaît ainsi que, pour diminuer l'inductance équivalente série, il vaut mieux employer des bobinages plats et des bobinages annulaires.

  15. Development of Laser Propulsion and Tracking System for Laser-Driven Micro-Airplane

    NASA Astrophysics Data System (ADS)

    Ishikawa, Hiroyasu; Kajiwara, Itsuro; Hoshino, Kentaro; Yabe, Takashi; Uchida, Shigeaki; Shimane, Yoshichika

    2004-03-01

    The purposes of this paper are to improve the control performance of the developed laser tracking system and to develop an integrated laser propulsion/tracking system for realizing a continuous flight and control of the micro-airplane. The laser propulsion is significantly effective to achieve the miniaturization and lightening of the micro-airplane. The laser-driven micro-airplane has been studied with a paper-craft airplane and YAG laser, resulting in a successful glide of the airplane. In the next stage of the laser-driven micro-airplane development, the laser tracking is expected as key technologies to achieve continuous propulsion. Furthermore, the laser propulsion system should be combined with the laser tracking system to supply continuous propulsion. Experiments are carried out to evaluate the performance of the developed laser tracking system and integrated laser propulsion/tracking system.

  16. Noninvasive evaluation of tissue-engineered cartilage with time-resolved laser-induced fluorescence spectroscopy.

    PubMed

    Kutsuna, Toshiharu; Sato, Masato; Ishihara, Miya; Furukawa, Katsuko S; Nagai, Toshihiro; Kikuchi, Makoto; Ushida, Takashi; Mochida, Joji

    2010-06-01

    Regenerative medicine requires noninvasive evaluation. Our objective is to investigate the application of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) using a nano-second-pulsed laser for evaluation of tissue-engineered cartilage (TEC). To prepare scaffold-free TEC, articular chondrocytes from 4-week-old Japanese white rabbits were harvested, and were inoculated at a high density in a mold. Cells were cultured for 5 weeks by rotating culture (RC) or static culture (SC). The RC group and SC group at each week (n = 5), as well as normal articular cartilage and purified collagen type II (as controls), were analyzed by TR-LIFS. The peak wavelength was compared with those of type II collagen immunostaining and type II collagen quantification by enzyme-linked immunosorbent assay and tensile testing. The fluorescence peak wavelength of the TEC analyzed by this method shifted significantly in the RC group at 3 weeks, and in the SC group at 5 weeks (p < 0.01). These results correlated with changes in type II collagen (enzyme-linked immunosorbent assay) and changes in Young's modulus on tensile testing. The results were also supported by immunohistologic findings (type II collagen staining). Our findings show that TR-LIFS is useful for evaluating TEC.

  17. Evaluation of the Diode laser (810nm, 980 nm) on color change of teeth after external bleaching

    PubMed Central

    Kiomars, Nazanin; Azarpour, Pouneh; Mirzaei, Mansooreh; Hashemi kamangar, Sedighe Sadat; Kharazifard, Mohammad Javad

    2016-01-01

    Subject and aim: The aim of this study was to evaluate the efficiency of diode laser-activated bleaching systems for color change of teeth. Materials & Methods: 40 premolars with intact enamel surfaces were selected for five external bleaching protocols (n=8). Two different wavelengths of diode laser (810 and 980 nm) with two different hydrogen peroxide concentrations (30% and 46%) were selected for laser bleaching. Group 1 received bleaching (Heydent- Germany) with a 810 nm diode laser; Group 2 received bleaching (Heydent- Germany) with a 980 nm diode laser; Group 3 received bleaching (laser white*20- Biolase) with a 810 nm diode laser; Group 4 received bleaching (laser white*20- Biolase) with a 980 nm diode laser, with an output power of 1.5 W, in continuous wave (cw) mode for each irradiation. Group 5 as control group received 40% hydrogen peroxide (Opalescence Boost, Ultradent-USA) with no light activation. The color of teeth was scored at baseline and 1 week after bleaching with spectrophotometer. Color change data on the CIEL*a*b* system were analyzed statistically by the one-way ANOVA and Tukey's HSD test. Results: All the bleaching techniques resulted in shade change. According to ΔE values, all techniques were effective to bleach the teeth (ΔE ≥ 3). Statistically significant differences were detected among bleaching protocols (p=0.06). Regarding shade change values expressed as ΔL*, Δa*, Δb*, ΔE*, laser bleached groups were no statistically different with each other (p>0.05). Conclusion: Bleaching with different wavelengths of diode laser resulted in the same results. PMID:28765671

  18. Techniques d'inspection par ondes guidees ultrasonores d'assemblages brases dans des reacteurs aeronautiques =

    NASA Astrophysics Data System (ADS)

    Comot, Pierre

    L'industrie aeronautique, cherche a etudier la possibilite d'utiliser de maniere structurelle des joints brases, dans une optique de reduction de poids et de cout. Le developpement d'une methode d'evaluation rapide, fiable et peu couteuse pour evaluer l'integrite structurelle des joints apparait donc indispensable. La resistance mecanique d'un joint brase dependant principalement de la quantite de phase fragile dans sa microstructure. Les ondes guidees ultrasonores permettent de detecter ce type de phase lorsqu'elles sont couplees a une mesure spatio-temporelle. De plus la nature de ce type d'ondes permet l'inspection de joints ayant des formes complexes. Ce memoire se concentre donc sur le developpement d'une technique basee sur l'utilisation d'ondes guidees ultrasonores pour l'inspection de joints brases a recouvrement d'Inconel 625 avec comme metal d'apport du BNi-2. Dans un premiers temps un modele elements finis du joint a ete utilise pour simuler la propagation des ultrasons et optimiser les parametres d'inspection, la simulation a permis egalement de demontrer la faisabilite de la technique pour la detection de la quantite de phase fragile dans ce type de joints. Les parametres optimises sont la forme de signal d'excitation, sa frequence centrale et la direction d'excitation. Les simulations ont montre que l'energie de l'onde ultrasonore transmise a travers le joint aussi bien que celle reflechie, toutes deux extraites des courbes de dispersion, etaient proportionnelles a la quantite de phase fragile presente dans le joint et donc cette methode permet d'identifier la presence ou non d'une phase fragile dans ce type de joint. Ensuite des experimentations ont ete menees sur trois echantillons typiques presentant differentes quantites de phase fragile dans le joint, pour obtenir ce type d'echantillons differents temps de brasage ont ete utilises (1, 60 et 180 min). Pour cela un banc d'essai automatise a ete developpe permettant d'effectuer une analyse similaire

  19. Evaluation of elastic properties of nanoporous silicon oxide thin films by picosecond laser ultrasonics

    NASA Astrophysics Data System (ADS)

    Mechri, C.; Ruello, P.; Gusev, V.; Breteau, J. M.; Mounier, D.; Henderson, M.; Gibaud, A.; Dourdain, S.

    2008-01-01

    Picosecond laser ultrasonics uses femtosecond laser pulses for the generation and detection of acoustic pulses with a typical duration between few picoseconds and few hundreds of pico seconds. The shorter the duration of the acoustic pulse is, the more precisely could be made the measurements of the film thickness [C. Thomsen et al., Phys. Rev. B 34, 4129 (1986)] and the elastic modulus by pulse-echo method or through Brillouin scattering detection. In this short communication we report the results of the evaluation of the properties of nanoporous silicon oxide thin films which present potential low-k and thermal barrier properties and are also of great interest for the microelectronic industry to replace the traditional silicate glass films in order to decrease the resistance-capacitance transition delay in the VLSI circuits. Most of the studies that have been carried so far have treated the optical properties of such structures. We report the results of the evaluation of acoustic properties of nanoporous thin films.

  20. Evaluation and correction for optical scattering variations in laser speckle rheology of biological fluids.

    PubMed

    Hajjarian, Zeinab; Nadkarni, Seemantini K

    2013-01-01

    Biological fluids fulfill key functionalities such as hydrating, protecting, and nourishing cells and tissues in various organ systems. They are capable of these versatile tasks owing to their distinct structural and viscoelastic properties. Characterizing the viscoelastic properties of bio-fluids is of pivotal importance for monitoring the development of certain pathologies as well as engineering synthetic replacements. Laser Speckle Rheology (LSR) is a novel optical technology that enables mechanical evaluation of tissue. In LSR, a coherent laser beam illuminates the tissue and temporal speckle intensity fluctuations are analyzed to evaluate mechanical properties. The rate of temporal speckle fluctuations is, however, influenced by both optical and mechanical properties of tissue. Therefore, in this paper, we develop and validate an approach to estimate and compensate for the contributions of light scattering to speckle dynamics and demonstrate the capability of LSR for the accurate extraction of viscoelastic moduli in phantom samples and biological fluids of varying optical and mechanical properties.

  1. Evaluation and Correction for Optical Scattering Variations in Laser Speckle Rheology of Biological Fluids

    PubMed Central

    Hajjarian, Zeinab; Nadkarni, Seemantini K.

    2013-01-01

    Biological fluids fulfill key functionalities such as hydrating, protecting, and nourishing cells and tissues in various organ systems. They are capable of these versatile tasks owing to their distinct structural and viscoelastic properties. Characterizing the viscoelastic properties of bio-fluids is of pivotal importance for monitoring the development of certain pathologies as well as engineering synthetic replacements. Laser Speckle Rheology (LSR) is a novel optical technology that enables mechanical evaluation of tissue. In LSR, a coherent laser beam illuminates the tissue and temporal speckle intensity fluctuations are analyzed to evaluate mechanical properties. The rate of temporal speckle fluctuations is, however, influenced by both optical and mechanical properties of tissue. Therefore, in this paper, we develop and validate an approach to estimate and compensate for the contributions of light scattering to speckle dynamics and demonstrate the capability of LSR for the accurate extraction of viscoelastic moduli in phantom samples and biological fluids of varying optical and mechanical properties. PMID:23705028

  2. Clinical Evaluation of Nd:YAG and 685-nm Diode Laser Therapy for Desensitization of Teeth with Gingival Recession

    PubMed Central

    Canakci, Varol; Ozdemir, Atilla; Kaya, Yavuz

    2009-01-01

    Abstract Objectives: The aim of this study was to evaluate the effectiveness of two types of lasers, the Nd:YAG laser and the 685-nm diode laser, as dentin desensitizers as well as both the immediate and late therapeutic effects on teeth with gingival recession. Materials and Methods: The study was conducted on 56 teeth in 14 patients with Miller's class 1 and 2 gingival recession with clinically elicitable dentin hypersensitivity (DH). The patients were divided into two groups: a Nd:YAG-laser-treated group and a 685-nm diode laser-treated group. DH was assessed by means of an air stimulus, and a visual analog scale (VAS) was used to measure DH. The selected teeth in the two groups received laser therapy for three sessions. Teeth subjected to Nd:YAG-laser treatment were irradiated at 1 W and 10 Hz for 60 sec at 1064 nm, and those receiving 685-nm diode laser treatment were irradiated at 25 mW and 9 Hz for 100 sec. Results: Significant reductions in DH occurred at all time points measured during the three treatment sessions in both treatment groups. Comparing the means of the responses in the three treatment sessions for the two groups revealed that the Nd:YAG laser group had a higher degree of desensitization compared to the other group (p < 0.01). The immediate and late therapeutic effects of the Nd:YAG laser were more evident than those of the 685-nm diode laser. Conclusions: Both of these lasers can be used to reduce DH without adverse effects. Desensitization of teeth with gingival recession with the Nd:YAG laser was more effective than with the diode laser. The Nd:YAG laser appears to be a promising new tool for successfully reducing DH. PMID:19281413

  3. Evaluation of blood microcirculation parameters by combined use of laser Doppler flowmetry and videocapillaroscopy methods

    NASA Astrophysics Data System (ADS)

    Volkov, M. V.; Kostrova, D. A.; Margaryants, N. B.; Gurov, I. P.; Erofeev, N. P.; Dremin, V. V.; Zharkikh, E. V.; Zherebtsov, E. A.; Kozlov, I. O.; Dunaev, A. V.

    2017-03-01

    Laser Doppler flowmetry (LDF) is widely used for diagnosing blood microcirculation diseases. It is well known that the Doppler shift of laser radiation scattered by moving red blood cells (RBC) can be assessed through analyzing photocurrent produced by a photodetector. LDF signal contains information about regulating blood flow rhythms: myogenic, cardiac, nervous and endothelial. The method of videocapillaroscopy (VCS) allows local capillary blood flow velocity evaluation and, using video data processing algorithms, is able to assess RBC velocity changes into capillary. We present the results of simultaneous investigations of changes in tissue perfusion of the distal phalanx of human finger by the LDF as well as changes in capillary blood flow velocity in the nail bed evaluated by the VCS method during arterial occlusion test. The experimental results confirmed the correspondence between blood perfusion and blood flow velocity.

  4. Evaluation of Wavelength Detuning to Mitigate Cross-Beam Energy Transfer Using the Nike Laser

    NASA Astrophysics Data System (ADS)

    McKenty, P. W.; Delettrez, J. A.; Marozas, J. A.; Weaver, J.; Obenschain, S.; Schmitt, A.

    2014-10-01

    Cross-beam energy transfer (CBET) has become a serious threat to the overall success of polar-drive-ignition experiments. CBET redirects incident laser light before it can be absorbed into the target, thereby degrading overall target performance. CBET is particularly effective over the equator of the target, which is hydrodynamically very sensitive to such losses. A promising solution uses laser wavelength detuning between beams to break the resonance between them and reduce energy transfer. Testing this process for direct drive has been limited because of the lack of sufficient detuning capabilities. However, the Naval Research Laboratory's Nike laser has the capability of providing a wide range of detuning between its main drive and backlighter beams. This paper explores the design of an experimental platform on Nike to directly evaluate the benefit of frequency detuning in mitigating CBET. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  5. Evaluating the speed of visual recovery following thin-flap LASIK with a femtosecond laser.

    PubMed

    Durrie, Daniel S; Brinton, Jason P; Avila, Michele R; Stahl, Erin D

    2012-09-01

    To investigate the speed of visual recovery following myopic thin-flap LASIK with a femtosecond laser. This pilot study prospectively evaluated 20 eyes from 10 patients who underwent bilateral simultaneous LASIK with the Femto LDV Crystal Line femtosecond laser (Ziemer Ophthalmic Systems AG) used to create a circular flap of 9.0-mm diameter and 110-μm thickness followed by photoablation with the Allegretto Wave Eye-Q (WaveLight AG) excimer laser. Binocular and monocular uncorrected distance visual acuity (UDVA), monocular contrast sensitivity, and a patient questionnaire were evaluated during the first hours, 1 day, and 1 month postoperatively. For monocular UDVA, 100% of eyes were 20/40 at 1 hour and 100% were 20/25 at 4 hours. For binocular UDVA, all patients achieved 20/32 by 30 minutes and 20/20 by 4 hours. Low frequency contrast sensitivity returned to preoperative baseline by 1 hour (P=.73), and showed a statistically significant improvement over baseline by 4 hours (P=.01). High frequency monocular contrast sensitivity returned to preoperative baseline by 4 hours (P=.48), and showed a statistically significant improvement by 1 month (P=.04). At 2 and 4 hours, 50% and 100% of patients, respectively, indicated that they would feel comfortable driving. Visual recovery after thin-flap femtosecond LASIK is rapid, occurring within the first few hours after surgery. Copyright 2012, SLACK Incorporated.

  6. Apport des neutrons à l'analyse structurale des composés partiellement désordonnés

    NASA Astrophysics Data System (ADS)

    Cousson, A.

    2003-02-01

    La cristallographie est un outil extrêmement puissant qui pourrait être utilisé par de nombreux scientifiques dont les sujets de recherche sont en fait très éloignés. L'évolution des techniques ces dernières années a relégué par exemple la cristallographie des rayons X des petites molécules à un rôle mineur, un rôle de service. Certains ont même le sentiment semble-t-il que toutes les connaissances sont contenues dans de multiples logiciels capables par eux-mêmes de conduire une analyse structurale à un résultat correct unique. Il est souhaitable que chacun soit capable de réaliser l'étude structurale du composé qui l'intéresse et bien entendu nécessaire de comprendre ce que l'on fait, la qualité des résultats et leur analyse en dépend. L'objet de cette présentation est de montrer l'apport spécifique de la diffraction de neutrons sur monocristaux à l'étude du désordre, en particulier des atomes d'hydrogène, et ses conséquences sur la compréhension des propriétés physiques, à partir de développements et d'exemples récents.

  7. Environmental Assessment for Employment of a Mobile Laser Evaluator System (LES-M) for the 20th Fighter Wing at Shaw Air Force Base, South Carolina

    DTIC Science & Technology

    2004-05-01

    Environmental Assessment for Employment of a Mobile Laser Evaluator System (LES-M) for the 20th Fighter Wing at Shaw Air Force Base, South Carolina...Mobile Laser Evaluator System (LES-M) for the 20th Fighter Wing at Shaw Air Force Base, South Carolina 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM...a Mobile Laser Evaluator System (LES-M) for the 20’’ Fighter Wing (20 fW) at Shaw Air Force Base (AFB), South Carolir.a DESCRIPTION OF THE PROPOSED

  8. Laser Speckle Rheology for evaluating the viscoelastic properties of hydrogel scaffolds

    PubMed Central

    Hajjarian, Zeinab; Nia, Hadi Tavakoli; Ahn, Shawn; Grodzinsky, Alan J.; Jain, Rakesh K.; Nadkarni, Seemantini K.

    2016-01-01

    Natural and synthetic hydrogel scaffolds exhibit distinct viscoelastic properties at various length scales and deformation rates. Laser Speckle Rheology (LSR) offers a novel, non-contact optical approach for evaluating the frequency-dependent viscoelastic properties of hydrogels. In LSR, a coherent laser beam illuminates the specimen and a high-speed camera acquires the time-varying speckle images. Cross-correlation analysis of frames returns the speckle intensity autocorrelation function, g2(t), from which the frequency-dependent viscoelastic modulus, G*(ω), is deduced. Here, we establish the capability of LSR for evaluating the viscoelastic properties of hydrogels over a large range of moduli, using conventional mechanical rheometry and atomic force microscopy (AFM)-based indentation as reference-standards. Results demonstrate a strong correlation between |G*(ω)| values measured by LSR and mechanical rheometry (r = 0.95, p < 10−9), and z-test analysis reports that moduli values measured by the two methods are identical (p > 0.08) over a large range (47 Pa – 36 kPa). In addition, |G*(ω)| values measured by LSR correlate well with indentation moduli, E, reported by AFM (r = 0.92, p < 10−7). Further, spatially-resolved moduli measurements in micro-patterned substrates demonstrate that LSR combines the strengths of conventional rheology and micro-indentation in assessing hydrogel viscoelastic properties at multiple frequencies and small length-scales. PMID:27905494

  9. Laser Speckle Rheology for evaluating the viscoelastic properties of hydrogel scaffolds.

    PubMed

    Hajjarian, Zeinab; Nia, Hadi Tavakoli; Ahn, Shawn; Grodzinsky, Alan J; Jain, Rakesh K; Nadkarni, Seemantini K

    2016-12-01

    Natural and synthetic hydrogel scaffolds exhibit distinct viscoelastic properties at various length scales and deformation rates. Laser Speckle Rheology (LSR) offers a novel, non-contact optical approach for evaluating the frequency-dependent viscoelastic properties of hydrogels. In LSR, a coherent laser beam illuminates the specimen and a high-speed camera acquires the time-varying speckle images. Cross-correlation analysis of frames returns the speckle intensity autocorrelation function, g 2 (t), from which the frequency-dependent viscoelastic modulus, G*(ω), is deduced. Here, we establish the capability of LSR for evaluating the viscoelastic properties of hydrogels over a large range of moduli, using conventional mechanical rheometry and atomic force microscopy (AFM)-based indentation as reference-standards. Results demonstrate a strong correlation between |G*(ω)| values measured by LSR and mechanical rheometry (r = 0.95, p < 10 -9 ), and z-test analysis reports that moduli values measured by the two methods are identical (p > 0.08) over a large range (47 Pa - 36 kPa). In addition, |G*(ω)| values measured by LSR correlate well with indentation moduli, E, reported by AFM (r = 0.92, p < 10 -7 ). Further, spatially-resolved moduli measurements in micro-patterned substrates demonstrate that LSR combines the strengths of conventional rheology and micro-indentation in assessing hydrogel viscoelastic properties at multiple frequencies and small length-scales.

  10. Evaluation of wavelength-dependent hair growth effects on low-level laser therapy: an experimental animal study.

    PubMed

    Kim, Tae-Hoon; Kim, Nam-Jeong; Youn, Jong-In

    2015-08-01

    In this study, we aimed to investigate the wavelength-dependent effects of hair growth on the shaven backs of Sprague-Dawley rats using laser diodes with wavelengths of 632, 670, 785, and 830 nm. Each wavelength was selected by choosing four peak wavelengths from an action spectrum in the range 580 to 860 nm. The laser treatment was performed on alternating days over a 2-week period. The energy density was set to 1.27 J/cm(2) for the first four treatments and 1.91 J/cm(2) for the last four treatments. At the end of the experiment, both photographic and histological examinations were performed to evaluate the effect of laser wavelength on hair growth. Overall, the results indicated that low-level laser therapy (LLLT) with a 830-nm wavelength resulted in greater stimulation of hair growth than the other wavelengths examined and 785 nm also showed a significant effect on hair growth.

  11. Evaluation of laser-driven ion energies for fusion fast-ignition research

    NASA Astrophysics Data System (ADS)

    Tosaki, S.; Yogo, A.; Koga, K.; Okamoto, K.; Shokita, S.; Morace, A.; Arikawa, Y.; Fujioka, S.; Nakai, M.; Shiraga, H.; Azechi, H.; Nishimura, H.

    2017-10-01

    We investigate laser-driven ion acceleration using kJ-class picosecond (ps) laser pulses as a fundamental study for ion-assisted fusion fast ignition, using a newly developed Thomson-parabola ion spectrometer (TPIS). The TPIS has a space- and weight-saving design, considering its use in an laser-irradiation chamber in which 12 beams of fuel implosion laser are incident, and, at the same time, demonstrates sufficient performance with its detectable range and resolution of the ion energy required for fast-ignition research. As a fundamental study on laser-ion acceleration using a ps pulse laser, we show proton acceleration up to 40 MeV at 1 × 10^{19} W cm^{-2}. The energy conversion efficiency from the incident laser into protons higher than 6 MeV is 4.6%, which encourages the realization of fusion fast ignition by laser-driven ions.

  12. Apport des moyens endoscopiques dans la dilatation des sténoses caustiques de l’œsophage

    PubMed Central

    Seydou, Togo; Abdoulaye, Ouattara Moussa; xing, Li; Zi, Sanogo Zimogo; sekou, Koumaré; Wen, Yang Shang; Ibrahim, Sankare; Sekou, Toure Cheik Ahmed; Boubacar, Maiga Ibrahim; Saye, Jacque; Jerome, Dakouo Dodino; Dantoumé, Toure Ousmane; Sadio, Yena

    2016-01-01

    Introduction Toutes les sténoses symptomatiques de l’œsophage peuvent être dilatées par voie endoscopique. Nous évaluons l'apport des moyens endoscopiques dans la prise en charge de la dilatation œsophagienne pour sténose caustique de l’œsophage (SCO) au Mali. Méthodes IL s'agissait d'une étude descriptive et prospective réalisée dans le service de chirurgie thoracique à l'hôpital du Mali. Au total 46 dossiers cliniques de patients on été enregistrés et subdivisés en 4 groupes en fonction de la topographie des lésions cicatricielles. Le nombre de cas d'assistance endoscopique réalisé a été déterminé afin de comprendre l'apport des moyens endoscopiques dans le succès de la dilatation des SCO. Pour les 2 différentes méthodes de dilatation utilisées, le résultat du traitement et le coût ont comparés. Résultats La FOGD a été utilisée dans 19 cas (41.30%) de dilatation avec la bougie de Savary Guillard et dans 47.82% des cas dans la dilatation de Lerut. La vidéo-laryngoscopie a été utilisé 58.69% des cas de dilatation à la bougie de Lerut. Le passage de guide métallique et / ou de fil-guide a été réalisée dans 39.13% avec la vidéo laryngoscopie et dans 58.68% avec la FOGD. Dans la comparaison des deux méthodes, il existe une différence significative dans la survenue des complications (p=0.04075), l'anesthésie générale (p=0.02287), l'accessibilité à la méthode (p=0.04805) et la mortalité (p=0.00402). Conclusion La SCO est une pathologie grave et sous évaluée au Mali. Les moyens endoscopiques contribuent considérablement au succès de la dilatation œsophagienne pour sténose caustique dans les différentes méthodes utilisées. PMID:27200129

  13. Fissuration en relaxation des aciers inoxydables austénitiques au voisinage des soudures

    NASA Astrophysics Data System (ADS)

    Auzoux, Q.; Allais, L.; Gourgues, A. F.; Pineau, A.

    2003-03-01

    Des fissures intergranulaires peuvent se développer au voisinage des soudures des aciers inoxydables austénitiques lorsqu'ils sont réchauffés dans le domaine de température compris entre 500^{circ}C et 700^{circ}C. A ces températures, les contraintes résiduelles post-soudage se relaxent par déformation viscoplastique. Il peut arriver que ces zones proches de la soudure soient tellement fragiles, qu'elles ne puissent accommoder cette faible déformation. Afin de préciser quelles peuvent être les modifications microstructurales qui conduisent à une telle fragilisation, on a examiné les microstructures de ces zones et révélé ainsi un écrouissage résiduel, responsable d'une forte élévation de la dureté. On a pu reproduire par hypertrempe puis laminage entre 400^{circ}C et 600^{circ}C une microstructure similaire. Des essais mécaniques (traction, fluage, relaxation, sur éprouvettes lisses et pré-fissurées) ont été réalisés à 550^{circ}C et à 600^{circ}C sur ces zones affectées simulées et sur un état de référence hypertrempé. Ils ont montré que l'écrouissage diminuait la ductilité dans le domaine de rupture intergranulaire, sans modifier qualitativement le mécanisme d'endommagement. Pendant la pré-déformation les incompatibilités de déformation entre grains conduiraient à l'existence de contraintes locales élevées qui favoriseraient la germination des cavités intergranulaires.

  14. Application of laser speckle contrast image in the evaluation of arthritis animal model

    NASA Astrophysics Data System (ADS)

    Son, Taeyoon; Jang, Won Hyuk; Park, Jihoon; Yoon, Hyung-Ju; Lee, Jeon; Kim, Wan-Uk; Jung, Byungjo

    2013-03-01

    Arthritis is a chronic inflammatory disease that induces potentially damaging and commonly disabling. Various imaging modalities have been used for the evaluation of arthritis. This study aimed to investigate the feasibility of laser speckle contrast image (LSCI) in the evaluation of the severity and early stage of arthritis in animal model. Arthritis was induced on mouse foot and evaluated by a trained expert and the LSCI. The arthritis severity was quantitatively evaluated by speckle index (SI) computed from LSCI. In visual inspection by an expert, it was difficult to evaluate the arthritis because there was no noticeable different between control mouse group (CMG) and arthritis mouse group (AMG) in erythema. However, arthritis was easily evaluated by significant SI different between the CMG and AMG. In addition, the LSCI also successfully evaluated the early stage of arthritis, presenting different SI distribution depending on lesion.

  15. Surgical lasers in dermatology

    NASA Astrophysics Data System (ADS)

    Szymanczyk, Jacek; Nowakowski, Wlodzimierz; Golebiowska, Aleksandra; Michalska, I.; Mindak, Marek K.

    1997-10-01

    Almost every laser for medical applications was first tried in dermatology. The efficiency of YAG, CO2, and Argon lasers on this area and their potential advantages over conventional methods were mostly evaluated by cosmetic effect of laser therapy. The indications for different laser treatment in such dermatological cases as: angiomas, telangiectasias, pigmented lesions, nevus flammeus congenitus, deep cavernous angiomas, skin neoplasms and condylomata acuminata are discussed in this paper and the results of the laser therapy are also presented.

  16. Comparaison des effets des irradiations γ, X et UV dans les fibres optiques

    NASA Astrophysics Data System (ADS)

    Girard, S.; Ouerdane, Y.; Baggio, J.; Boukenter, A.; Meunier, J.-P.; Leray, J.-L.

    2005-06-01

    Les fibres optiques présentent de nombreux avantages incitant à les intégrer dans des applications devant résister aux environnements radiatifs associés aux domaines civil, spatial ou militaire. Cependant, leur exposition à un rayonnement entraîne la création de défauts ponctuels dans la silice amorphe pure ou dopée qui constitue les différentes parties de la fibre optique. Ces défauts causent, en particulier, une augmentation transitoire de l'atténuation linéique des fibres optiques responsable de la dégradation voire de la perte du signal propagé dans celles-ci. Dans cet article, nous comparons les effets de deux types d'irradiation: une impulsion X et une dose γ cumulée. Les effets de ces irradiations sont ensuite comparés avec ceux induits par une insolation ultraviolette (244 nm) sur les propriétés d'absorption des fibres optiques. Nous montrons qu'il existe des similitudes entre ces différentes excitations et qu'il est possible, sous certaines conditions, d'utiliser celles-ci afin d'évaluer la capacité de certaines fibres optiques à fonctionner dans un environnement nucléaire donné.

  17. Laser treatment of solar lentigines on dorsum of hands: QS Ruby laser versus ablative CO2 fractional laser - a randomized controlled trial.

    PubMed

    Schoenewolf, Nicola L; Hafner, Jürg; Dummer, Reinhard; Bogdan Allemann, Inja

    2015-04-01

    Lentigines solares (LS) on the dorsum of hands are often esthetically disturbing. Q-switched ruby laser treatment is highly effective in the treatment of these lesions. Ablative fractional photothermolysis may be a suitable alternative. We compared the Q-switched ruby laser with ablative CO2 fractional photothermolysis for the treatment of solar lentigines. To evaluate the efficacy and side-effects of 694nm Q-switched ruby laser (Sinon) with the ablative 10,600nm CO2 fractional laser (Quantel Excel O2) in an intra-individual side-to-side comparison in the treatment of LS on the dorsum of hands. Eleven patients were included in the study. The hands of each patient were randomized for treatment with the two laser systems. Three treatment sessions were scheduled at weeks 0, 4 and 8. Evaluations by patients, treating physician and blinded experts were scheduled at weeks 0, 4, 8, 16 and 24. The Q-switched ruby laser was significantly more efficacious than the ablative CO2 fractional laser for removing LS on the dorsum of hands (p = 0.01). In this first study on this topic, the Q-switched ruby laser was superior to the ablative CO2 fractional laser in the treatment of lentigines solares on the dorsum of hands.

  18. Evaluating platelet aggregation dynamics from laser speckle fluctuations.

    PubMed

    Hajjarian, Zeinab; Tshikudi, Diane M; Nadkarni, Seemantini K

    2017-07-01

    Platelets are key to maintaining hemostasis and impaired platelet aggregation could lead to hemorrhage or thrombosis. We report a new approach that exploits laser speckle intensity fluctuations, emanated from a drop of platelet-rich-plasma (PRP), to profile aggregation. Speckle fluctuation rate is quantified by the speckle intensity autocorrelation, g 2 (t) , from which the aggregate size is deduced. We first apply this approach to evaluate polystyrene bead aggregation, triggered by salt. Next, we assess dose-dependent platelet aggregation and inhibition in human PRP spiked with adenosine diphosphate and clopidogrel. Additional spatio-temporal speckle analyses yield 2-dimensional maps of particle displacements to visualize platelet aggregate foci within minutes and quantify aggregation dynamics. These findings demonstrate the unique opportunity for assessing platelet health within minutes for diagnosing bleeding disorders and monitoring anti-platelet therapies.

  19. Qualification of an evaluated butterfly-packaged DFB laser designed for space applications

    NASA Astrophysics Data System (ADS)

    Tornow, S.; Stier, C.; Buettner, T.; Laurent, T.; Kneier, M.; Bru, J.; Lien, Y.

    2017-11-01

    An extended qualification program has proven the quality of a previously evaluated semiconductor laser diode, which is intended to be used in a subsystem for the GAIA mission. We report on results of several reliability tests performed in subgroups. The requirements of the procurement specification with respect to reliability and desired manufacturing processes were confirmed. This is an example for successful collaboration between component supplier, system integrator and payload responsible party.

  20. Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1995-01-01

    This Interim report consists of a manuscript, 'Receiver Design for Satellite to Satellite Laser Ranging Instrument,' and copies of two papers we co-authored, 'Demonstration of High Sensitivity Laser Ranging System' and 'Semiconductor Laser-Based Ranging Instrument for Earth Gravity Measurements. ' These two papers were presented at the conference Semiconductor Lasers, Advanced Devices and Applications, August 21 -23, 1995, Keystone Colorado. The manuscript is a draft in the preparation for publication, which summarizes the theory we developed on space-borne laser ranging instrument for gravity measurements.

  1. Vers des boites quantiques a base de graphene

    NASA Astrophysics Data System (ADS)

    Branchaud, Simon

    Le graphene est un materiau a base de carbone qui est etudie largement depuis 2004. De tres nombreux articles ont ete publies tant sur les proprietes electroniques, qu'optiques ou mecaniques de ce materiel. Cet ouvrage porte sur l'etude des fluctuations de conductance dans le graphene, et sur la fabrication et la caracterisation de nanostructures gravees dans des feuilles de ce cristal 2D. Des mesures de magnetoresistance a basse temperature ont ete faites pres du point de neutralite de charge (PNC) ainsi qu'a haute densite electronique. On trouve deux origines aux fluctuations de conductance pres du PNC, soit des oscillations mesoscopiques provenant de l'interference quantique, et des fluctuations dites Hall quantique apparaissant a plus haut champ (>0.5T), semblant suivre les facteurs de remplissage associes aux monocouches de graphene. Ces dernieres fluctuations sont attribuees a la charge d'etats localises, et revelent un precurseur a l'effet Hall quantique, qui lui, ne se manifeste pas avant 2T. On arrive a extraire les parametres caracterisant l'echantillon a partir de ces donnees. A la fin de cet ouvrage, on effectue des mesures de transport dans des constrictions et ilots de graphene, ou des boites quantiques sont formees. A partir de ces mesures, on extrait les parametres importants de ces boites quantiques, comme leur taille et leur energie de charge.

  2. Evaluation of laser bacterial anti-fouling of transparent nanocrystalline yttria-stabilized-zirconia cranial implant.

    PubMed

    Damestani, Yasaman; De Howitt, Natalie; Halaney, David L; Garay, Javier E; Aguilar, Guillermo

    2016-10-01

    The development and feasibility of a novel nanocrystalline yttria-stabilized-zirconia (nc-YSZ) cranial implant has been recently established. The purpose of what we now call "window to the brain (WttB)" implant (or platform), is to improve patient care by providing a technique for delivery and/or collection of light into/from the brain, on demand, over large areas, and on a chronically recurring basis without the need for repeated craniotomies. WttB holds the transformative potential for enhancing light-based diagnosis and treatment of a wide variety of brain pathologies including cerebral edema, traumatic brain injury, stroke, glioma, and neurodegenerative diseases. However, bacterial adhesion to the cranial implant is the leading factor for biofilm formation (fouling), infection, and treatment failure. Escherichia coli (E. coli), in particular, is the most common isolate in gram-negative bacillary meningitis after cranial surgery or trauma. The transparency of our WttB implant may provide a unique opportunity for non-invasive treatment of bacterial infection under the implant using medical lasers. A drop of a diluted overnight culture of BL21-293 E. coli expressing luciferase was seeded between the nc-YSZ implant and the agar plate. This was followed by immediate irradiation with selected laser. After each laser treatment the nc-YSZ was removed, and cultures were incubated for 24 hours at 37 °C. The study examined continuous wave (CW) and pulsed wave (PW) modes of near-infrared (NIR) 810 nm laser wavelength with a power output ranging from 1 to 3 W. During irradiation, the temperature distribution of nc-YSZ surface was monitored using an infrared thermal camera. Relative luminescence unit (RLU) was used to evaluate the viability of bacteria after the NIR laser treatment. Analysis of RLU suggests that the viability of E. coli biofilm formation was reduced with NIR laser treatment when compared to the control group (P < 0.01) and loss of viability

  3. Evaluation of tricuspid valve regurgitation following laser lead extraction†.

    PubMed

    Pecha, Simon; Castro, Liesa; Gosau, Nils; Linder, Matthias; Vogler, Julia; Willems, Stephan; Reichenspurner, Hermann; Hakmi, Samer

    2017-06-01

    The objective of this study was to examine the effect of laser lead extraction (LLE) on the development of post-procedural tricuspid regurgitation (TR). Some reports have suggested an increase in TR associated with LLE. We present a series of patients who underwent both, LLE and complete echocardiographic evaluation for TR. A single centre analysis of consecutive patients referred for LLE between January 2012 and August 2015. One hundred and three patients had tricuspid valve function evaluated before the procedure with a transthoracic echocardiography (TTE), during the procedure using transoesophageal echocardiography and postoperatively using a TTE. TR was graded from 0 (none) to 4 (severe). We treated 235 leads in 103 patients, including 118 ventricular leads. Seventy-seven were male (74.8%) and 26 female (25.2%), with a mean age of 65.6 ± 15.4 years. Mean time from initial lead implantation was 98.0 ± 67.3 months. Twenty-one patients (20.4%) had ejection fraction below 30%. No intra-procedural worsening of tricuspid valve function was seen with TEE in any of the patients. Ten patients (9.7%) were found to have TR before LLE that returned to normal valve function after the procedure. Two patients (1.9%) experienced mild TR after the procedure (both with tricuspid valve endocarditis). Ninety-one patients (88.3%) did not experience any significant change of the tricuspid valve function after LLE. Transthoracic and transoesophageal echocardiography findings showed that laser lead extraction was not associated with a significant increase in the incidence of tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Prise en charge des troubles de consommation d’opioïdes en première ligne

    PubMed Central

    Srivastava, Anita; Kahan, Meldon; Nader, Maya

    2017-01-01

    Résumé Objectif Conseiller les médecins quant aux options thérapeutiques à recommander à des populations précises de patients : approche axée sur l’abstinence, traitement d’entretien par la buprénorphine-naloxone ou traitement d’entretien par la méthadone. Sources d’information Une recherche sur PubMed a été effectuée, et on a relevé dans les publications les données sur l’efficacité, l’innocuité et le profil d’effets indésirables de l’approche axée sur l’abstinence, du traitement par la buprénorphine-naloxone et du traitement par la méthadone. Les études d’observation et interventionnelles ont été incluses. Message principal La méthadone et la buprénorphine-naloxone sont substantiellement plus efficaces que l’approche axée sur l’abstinence. La méthadone présente un taux de rétention plus élevé que la buprénorphine-naloxone, alors que la buprénorphine-naloxone présente un risque plus faible de surdose. Les médecins devraient recommander le traitement par la méthadone ou la buprénorphine-naloxone plutôt que l’approche axée sur l’abstinence, et ce, à tous les groupes de patients (données de niveau I). La méthadone est préférable à la buprénorphine-naloxone chez les patients qui présentent un risque élevé d’abandon, comme les usagers d’opioïdes par injection (données de niveau I). Les jeunes et les femmes enceintes qui font usage d’opioïdes par injection devraient aussi recevoir la méthadone d’abord (données de niveau III). Si la buprénorphine-naloxone est prescrite en premier, il faut faire passer rapidement le patient à la méthadone si les symptômes de sevrage, les fortes envies ou la consommation d’opioïdes persistent malgré une dose optimale de buprénorphine-naloxone (données de niveau II). La buprénorphine-naloxone est recommandée chez les usagers d’opioïdes sur ordonnance par voie orale socialement stables, surtout s’ils ont un emploi ou si leurs

  5. Seroprevalence of Sheep and Goat Pox, Peste Des Petits Ruminants and Rift Valley Fever in Saudi Arabia.

    PubMed

    Boshra, Hani; Truong, Thang; Babiuk, Shawn; Hemida, Maged Gomaa

    2015-01-01

    Sheep and goat pox, peste des petits ruminants and Rift Valley fever are important diseases of small ruminant livestock. Sheep and goat pox, along with peste des petits ruminants, are endemic throughout most of Africa, Asia and the Middle East. Whereas Rift Valley fever is endemic in Africa, outbreaks in the Middle East have been reported over the past decade, including the Arabian Peninsula. Saudi Arabia is a major importer of livestock, and understanding the prevalence of these viral infections would be useful for disease control. In this study, sera from sheep and goats were collected from 3 regions in Saudi Arabia. They were evaluated for antibodies specific to sheep and goat pox, peste des petits ruminants and Rift Valley fever by virus neutralization assays. To the best of our knowledge, this is the first study to evaluate the seroprevalence of these viruses in sheep and goats.

  6. Determination dans les Installations au Sol des Parametres Aerodynamiques de Stabilite des Aeronefs (Determination in Ground Facilities of Aerodynamic Stability Parameters of Aircraft),

    DTIC Science & Technology

    1979-06-01

    7 INTRODUCTION ...................................................................................... 12 CHAPITRE I : ELEMENTS DE DYNAMIQUE...daone Ie texts. 12 INTRODUCTION La ddtermination des ddrivdes adrodynamiques de stabilitd, en soufflerie et au tunnel de tir, aur des maquettes...ddtection des forces eat effectuds de fegon classiqus depuis plus de vingt ana par des barreaux d’acier dquipds de jauges de contrainte, gdndralament en

  7. Evaluation of a high framerate multi-exposure laser speckle contrast imaging setup

    NASA Astrophysics Data System (ADS)

    Hultman, Martin; Fredriksson, Ingemar; Strömberg, Tomas; Larsson, Marcus

    2018-02-01

    We present a first evaluation of a new multi-exposure laser speckle contrast imaging (MELSCI) system for assessing spatial variations in the microcirculatory perfusion. The MELSCI system is based on a 1000 frames per second 1-megapixel camera connected to a field programmable gate arrays (FPGA) capable of producing MELSCI data in realtime. The imaging system is evaluated against a single point laser Doppler flowmetry (LDF) system during occlusionrelease provocations of the arm in five subjects. Perfusion is calculated from MELSCI data using current state-of-the-art inverse models. The analysis displayed a good agreement between measured and modeled data, with an average error below 6%. This strongly indicates that the applied model is capable of accurately describing the MELSCI data and that the acquired data is of high quality. Comparing readings from the occlusion-release provocation showed that the MELSCI perfusion was significantly correlated (R=0.83) to the single point LDF perfusion, clearly outperforming perfusion estimations based on a single exposure time. We conclude that the MELSCI system provides blood flow images of enhanced quality, taking us one step closer to a system that accurately can monitor dynamic changes in skin perfusion over a large area in real-time.

  8. Process Evaluation of AISI 4340 Steel Manufactured by Laser Powder Bed Fusion

    NASA Astrophysics Data System (ADS)

    Jelis, Elias; Hespos, Michael R.; Ravindra, Nuggehalli M.

    2018-01-01

    Laser powder bed fusion (L-PBF) involves the consolidation of metal powder, layer by layer, through laser melting and solidification. In this study, process parameters are optimized for AISI 4340 steel to produce dense and homogeneous structures. The optimized process parameters produce mechanical properties at the center of the build plate that are comparable to wrought in the vertical and horizontal orientations after heat treatment and machining. Four subsequent builds are filled with specimens to evaluate the mechanical behavior as a function of location and orientation. Variations in the mechanical properties are likely due to recoater blade interactions with the powder and uneven gas flow. The results obtained in this study are analyzed to assess the reliability and reproducibility of the process. A different build evaluates the performance of near-net-shaped tensile specimens angled 35°-90° from the build plate surface (horizontal). Ductility measurements and surface roughness vary significantly as a function of the build angle. In the stress-relieved and as-built conditions, the mechanical behavior of vertically oriented specimens exhibits somewhat lower and more variable ductility than horizontally oriented specimens. Therefore, several process variables affect the mechanical properties of parts produced by the L-PBF process.

  9. Lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse

    PubMed Central

    Kahan, Meldon; Mailis-Gagnon, Angela; Wilson, Lynn; Srivastava, Anita

    2011-01-01

    Résumé Objectif Présenter aux médecins de famille un résumé clinique pratique des lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse, produites par le National Opioid Use Guideline Group. Qualité des données Pour produire les lignes directrices, les chercheurs ont effectué une synthèse critique de la littérature médicale sur l’efficacité et l’innocuité des opioïdes pour la douleur chronique non cancéreuse et ont rédigé une série de recommandations. Un panel de 49 cliniciens experts de toutes les régions du Canada ont passé en revue l’ébauche et ont atteint un consensus sur 24 recommandations. Message principal Il est recommandé de faire un dépistage du risque de dépendance avant de prescrire des opioïdes. On recommande des opioïdes faibles (codéine et tramadol) pour une douleur de légère à modérée qui n’a pas répondu aux traitements de première intention. On peut essayer l’oxycodone, l’hydromorphone et la morphine chez les patients qui n’ont pas eu de soulagement avec des opioïdes plus faibles. Une faible dose initiale et une lente hausse du titrage sont recommandées, ainsi qu’une étroite surveillance du patient qu’on a d’abord renseigné. Les médecins doivent surveiller l’apparition de complications comme l’apnée du sommeil. La dose optimale est celle qui améliore le fonctionnement ou atténue les cotes d’évaluation de la douleur d’au moins 30 %. Pour la grande majorité des patients, la dose optimale sera bien en deçà de l’équivalent de 200 mg de morphine par jour. On recommande le sevrage progressif pour les patients qui n’ont pas répondu à un essai d’opioïdes adéquat. Conclusion Les opioïdes jouent un rôle important dans la prise en charge de la douleur chronique non cancéreuse, mais il faut en prescrire avec prudence pour limiter les dommages potentiels. Les nouvelles lignes directrices

  10. Quantitative evaluation of the mechanical strength of titanium/composite bonding using laser-generated shock waves

    NASA Astrophysics Data System (ADS)

    Ducousso, M.; Bardy, S.; Rouchausse, Y.; Bergara, T.; Jenson, F.; Berthe, L.; Videau, L.; Cuvillier, N.

    2018-03-01

    Intense acoustic shock waves were applied to evaluate the mechanical strength of structural epoxy bonds between a TA6V4 titanium alloy and a 3D woven carbon/epoxy composite material. Two bond types with different mechanical strengths were obtained from two different adhesive reticulations, at 50% and 90% of conversion, resulting in longitudinal static strengths of 10 and 39 MPa and transverse strengths of 15 and 35 MPa, respectively. The GPa shock waves were generated using ns-scale intense laser pulses and reaction principles to a confined plasma expansion. Simulations taking into account the laser-matter interaction, plasma relaxation, and non-linear shock wave propagation were conducted to aid interpretation of the experiments. Good correlations were obtained between the experiments and the simulation and between different measurement methods of the mechanical strength (normalized tests vs laser-generated shock waves). Such results open the door toward certification of structural bonding.

  11. Shear bond strength and SEM morphology evaluation of different dental adhesives to enamel prepared with ER:YAG laser.

    PubMed

    Pires, Patrícia T; Ferreira, João C; Oliveira, Sofia A; Azevedo, Alvaro F; Dias, Walter R; Melo, Paulo R

    2013-01-01

    Early observations of enamel surfaces prepared by erbium lasers motivated clinicians to use laser as an alternative to chemical etching. Evaluate shear bond strength (SBS) values of different dental adhesives on Erbium:Yttrium Aluminum Garnet (Er:YAG) laser prepared enamel and to evaluate possible etching patterns correlations between dental adhesives and SBS values. One hundred bovine incisors were randomly assigned to SBS tests on enamel (n = 15) and to enamel morphology analysis (n = 5) after Er:YAG laser preparation as follows: Group I - 37% phosphoric acid (PA)+ ExciTE(®); Group II - ExciTE(®); Group III - AdheSE(®) self-etching; Group IV - FuturaBond(®) no-rinse. NR; Group V - Xeno(®) V. Teeth were treated with the adhesive systems and subjected to thermal cycling. SBS were performed in a universal testing machine at 5 mm/min. One-way ANOVA and post-hoc tests (P < 0.05). For the morphology evaluation, specimens were immersed in Ethylenediamine tetraacetic acid (EDTA) and the etching pattern analyzed under Scanning Electron Microscope (SEM). Mean bond strengths were Group I - 47.17 ± 1.61 MPa (type I etching pattern); Group II - 32.56 ± 1.64 MPa, Group III - 29.10 ± 1.34 MPa, Group IV - 23.32 ± 1.53 MPa (type III etching pattern); Group V - 24.43 MPa ± 1.55 (type II etching pattern). Different adhesive systems yielded significantly different SBSs. Acid etching significantly increased the adhesion in laser treated enamel. No differences in SBS values were obtained between AdheSE(®) and ExciTE(®) without condition with PA. FuturaBond(®) NR and Xeno(®) V showed similar SBS, which was lower in comparison to the others adhesives. No correlation between enamel surface morphology and SBS values was observed, except when PA was used.

  12. Evaluation of laser speckle contrast imaging as an intrinsic method to monitor blood brain barrier integrity

    PubMed Central

    Dufour, Suzie; Atchia, Yaaseen; Gad, Raanan; Ringuette, Dene; Sigal, Iliya; Levi, Ofer

    2013-01-01

    The integrity of the blood brain barrier (BBB) can contribute to the development of many brain disorders. We evaluate laser speckle contrast imaging (LSCI) as an intrinsic modality for monitoring BBB disruptions through simultaneous fluorescence and LSCI with vertical cavity surface emitting lasers (VCSELs). We demonstrated that drug-induced BBB opening was associated with a relative change of the arterial and venous blood velocities. Cross-sectional flow velocity ratio (veins/arteries) decreased significantly in rats treated with BBB-opening drugs, ≤0.81 of initial values. PMID:24156049

  13. Déprescription des antihyperglycémiants chez les personnes âgées

    PubMed Central

    Farrell, Barbara; Black, Cody; Thompson, Wade; McCarthy, Lisa; Rojas-Fernandez, Carlos; Lochnan, Heather; Shamji, Salima; Upshur, Ross; Bouchard, Manon; Welch, Vivian

    2017-01-01

    Résumé Objectif Formuler des lignes directrices fondées sur les données probantes afin d’aider les cliniciens à décider du moment et de la façon sécuritaire de réduire la dose des antihyperglycémiants, de mettre fin au traitement ou de passer à un autre agent chez les personnes âgées. Méthodes Nous nous sommes concentrés sur les données les plus probantes disponibles et avons cherché à obtenir les commentaires des professionnels de première ligne durant le processus de rédaction, de révision et d’adoption des lignes directrices. L’équipe était formée de 7 professionnels de la santé (2 médecins de famille, 3 pharmaciens, 1 infirmière praticienne et 1 endocrinologue) et d’une spécialiste de la méthodologie; les membres ont divulgué tout conflit d’intérêts. Nous avons eu recours à un processus rigoureux, y compris l’approche GRADE (Grading of Recommendations Assessment, Development and Evaluation) pour formuler les lignes directrices. Nous avons effectué une revue systématique dans le but d’évaluer les données probantes indiquant les bienfaits et les torts liés à la déprescription des antihyperglycémiants. Nous avons révisé les revues des torts liés à la poursuite du traitement antihyperglycémiant, et effectué des synthèses narratives des préférences des patients et des répercussions sur les ressources. Ces synthèses et évaluations de la qualité des données selon l’approche GRADE ont servi à formuler les recommandations. L’équipe a peaufiné le texte sur le contenu et les recommandations des lignes directrices par consensus et a synthétisé les considérations cliniques afin de répondre aux questions courantes des cliniciens de première ligne. Une version préliminaire des lignes directrices a été distribuée aux cliniciens et aux intervenants aux fins d’examen, et des révisions ont été apportées au texte à chaque étape. Un algorithme d’appui décisionnel a été conçu pour

  14. Comparison of experimental models for predicting laser-tissue interaction from 3.8-micron lasers

    NASA Astrophysics Data System (ADS)

    Williams, Piper C. M.; Winston, Golda C. H.; Randolph, Don Q.; Neal, Thomas A.; Eurell, Thomas E.; Johnson, Thomas E.

    2004-07-01

    The purpose of this study was to evaluate the laser-tissue interactions of engineered human skin and in-vivo pig skin following exposure to a single 3.8 micron laser light pulse. The goal of the study was to determine if these tissues shared common histologic features following laser exposure that might prove useful in developing in-vitro and in-vivo experimental models to predict the bioeffects of human laser exposure. The minimum exposure required to produce gross morphologic changes following a four microsecond, pulsed skin exposure for both models was determined. Histology was used to compare the cellular responses of the experimental models following laser exposure. Eighteen engineered skin equivalents (in-vitro model), were exposed to 3.8 micron laser light and the tissue responses compared to equivalent exposures made on five Yorkshire pigs (in-vivo model). Representative biopsies of pig skin were taken for histologic evaluation from various body locations immediately, one hour, and 24 hours following exposure. The pattern of epithelial changes seen following in-vitro laser exposure of the engineered human skin and in-vivo exposure of pig skin indicated a common histologic response for this particular combination of laser parameters.

  15. [Evaluation of root canal isthmus debridement efficacy of Er:YAG laser in combination with sodium hypochlorite].

    PubMed

    Zhou, Meng-Qi; Wang, Hao-Ming; Xiao, Jia-Qi; Hong, Jin

    2016-10-01

    To histologically evaluate the efficacy of sodium hypochlorite (NaClO) in combination with Er:YAG (erbium-doped yttrium aluminium garnet) laser in dissolving necrotic tissue and cleaning root canals as well as canal isthmuses. After scanned by cone-beam CT (CBCT), 50 well-prepared premolars with root canal isthmuses were selected and randomly assigned into 5 groups. They were subsequently subjected to different regimens as followed: group A-irrigated with 1% NaClO for 1 minute, group B- irradiated by Er:YAG laser at 0.5 W combined with 1% NaClO irrigation for 1 minute, group C- irradiated by Er:YAG laser at 1.0 W combined with 1% NaClO irrigation for 1 minute, group D- irradiated by Er:YAG laser at 2.0 W combined with 1% NaClO irrigation for 1 minute,group E- negative control. After histological preparation and staining, the cross-sections were evaluated for percentage of tissue removal from root canals and isthmuses. The cleanliness values were calculated using SPSS 13.0 software package. The mean percentage of root canals in group A, B, C and D was 95.24%, 96.53%、97.63% and 98.22%, respectively, and the mean percentage of isthmuses was 16.50%, 51.48%, 52.56% and 53.83%, respectively. The mean percentage of root canal and isthmus cleanliness values were significantly higher in group B, C and D (P<0.05) than that in group A. There was no significant differences of root canal and isthmus cleanliness among group B, C and D. Er:YAG laser combined with 1% NaClO irrigation may be used effectively in root canal and root canal isthmus cleanliness as a new method.

  16. Evaluation of Nd:YAG laser on partial oxygen saturation of pulpal blood in anterior hypersensitive teeth.

    PubMed

    Birang, Reza; Kaviani, Naser; Mohammadpour, Mehdi; Abed, Ahmad Moghareh; Gutknecht, Norbert; Mir, Maziar

    2008-07-01

    Dentine hypersensitivity has of long been known to be a common clinical problem in dental practices. Lasers have recently come to play a prominent role in the treatment of this disorder. They might, however, cause dental pulp damage. This study was conducted to evaluate the effect of Nd:yttrium-aluminum-garnet (YAG) laser on partial oxygen saturation of pulpal blood in sensitive anterior teeth. In this clinical trial, 65 hypersensitive teeth were selected and randomly allocated to two groups. The study group involved Nd:YAG laser treatment, while no treatment was employed for the control group. Using a pulse oximetry system, evaluations were preformed of the partial oxygen saturation in the pulpal blood before, immediately after, 1 week after, and 1 month after the treatment. The results were analyzed using the SPSS software and repeated-measures analysis of variance and paired-samples t tests. The mean partial oxygen saturation of the blood was found to be 85.4% in the study group, which was not significantly different from that of the control group. No significant differences were observed in the control group between the means obtained from pretreatment and post-treatment intervals (P > 0.05). The Post-treatment partial oxygen saturation mean rose to 89.3% (P = 0.001) and remained constant throughout the following week after it. However, no significant differences were found between the pretreatment partial oxygen saturation mean and the same measurement 1 month after treatment (P = 0.702). Nd:YAG laser therapy for dentine desensitization of anterior teeth caused no persistent changes in the partial oxygen saturation of pulpal blood. It may, therefore, be concluded that the diffusion of heat induced by the Nd:YAG laser into the pulp within the limit of the desensitization parameters cause no irreversible damages in the dental pulp.

  17. Stabilisation de l'etat de polarisation d'un laser par la conception et fabrication d'un miroir polarisant fait de couches minces nanostructurees

    NASA Astrophysics Data System (ADS)

    Doucet, Alexandre

    Ce manuscrit presente la conception et la fabrication d'un miroir polarisant fabrique avec la methode de deposition par incidence oblique communement appelee en anglais GLAD (GLancing Angle Deposition). Cette methode de deposition par GLAD permet de changer la nanostructure des revetements avec l'inclinaison et la rotation du substrat par rapport au flux de materiau evapore. Ceci nous permet d'ajuster l'indice de refraction et d'obtenir des revetements birefringents avec un materiau intrinsequement isotrope. Puisque l'indice de refraction peut etre change, les miroirs sont fabriques avec un seul materiau contrairement aux methodes usuelles qui necessite deux materiaux. Les proprietes optiques des echantillons sont mesurees avec l'aide de l'ellipsometrie. Des images avec un microscope electronique a balayage par transmission permettent de verifier Ia structure des revetements deposes. Les miroirs sont utilises comme coupleurs de sortie du resonateur d'un laser avec un milieu actif d'(Yb3+0.1 Y 0.9)3Al5O12, ou plus simplement Yb: YAG, pompe optiquement avec une diode laser. Ces cristaux presentent des proprietes optiques interessantes pour leur utilisation comme milieu actif, mais avec une structure cristalline cubique, ils donnent lieu a des faisceaux polarises aleatoirement. Les miroirs que nous fabriquons permettent d'obtenir une emission polarisee lineairement sans avoir a ajouter d'autres elements au resonateur. Les tests sont faits en regime continu et pulse avec un absorbant saturable de Cr : Y AG. Deux materiaux sont etudies, soit le WO3 et le TiO2, et ils nous permettent d'obtenir une emission polarisee lineairement dans le mode TEM 00 avec un rapport d'extinction de 1000 (30 dB), mais seuls les miroirs de TiO2 permettent une emission pulsee periodique avec une densite de puissance crete pres de 700+/-80 MW/cm2. En etudiant le rapport d'extinction en fonction du temps de pompage, nous remarquons que l'etat de polarisation est beaucoup plus stable que celui

  18. Histologic and photonic evaluation of a pulsed Nd:YAG laser for ablation of subcutaneous adipose tissue.

    PubMed

    Ichikawa, Kota; Tanino, Ryuzaburo; Wakaki, Moriaki

    2006-12-20

    Although various lasers are available, few of them are applicable in liposculpture. Laser interaction with fat tissue has not also been well documented. The aim of our study was to gather basic data on laser absorption in fat tissue and to analyze the relationship between laser energy and lipolysis for development of a more effective laser system. The transmittance rate in human fat specimens was measured by a spectrophotometer to determine the optimum wavelength. The absorption coefficient was used to evaluate laser absorption at a wavelength of 1064 nm. Areas of heat degeneration and evaporation were measured by scanning electron microscopy. The relation between laser energy and the areas was analyzed statistically among low-power and high-power groups and controls. Energy dispersion at the fiber tip was investigated and analyzed statistically using the far field pattern. A graph of the absorption rate at wavelengths from 400 to 2400 nm showed a peak near 1700 nm and increases at wavelengths over 2000 nm. The formula gave as an absorption coefficient of 0.4 cm(-1), and involvement of the photo-acoustic effect and non-linear effect with short-pulse and high-peak energy was suggested. Findings of tissue evaporation, destruction, heat coagulation, and rupture of cell membrane were more frequently seen in irradiated specimens than in controls in scanning electron microscopy. The destroyed area in the low-power irradiated groups was significantly larger than that of controls in the statistical analysis. The affected area in the high-power irradiated groups was significantly larger than that of low-power specimens. Energy was concentrated at the tip with laser coherency. Energy at the oblique-cut tip was statistically lower than that at the normal tip, revealing that durability and maintenance of the fiber tip is essential to maintain energy levels in clinical practice. This study is the first to demonstrate the histologic and photonic relationship of energy absorption

  19. Synthesis and evaluation of ultra-pure rare-earth-coped glass for laser refrigeration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, Wendy M; Hehlen, Markus P; Epstein, Richard I

    2009-01-01

    Significant progress has been made in synthesizing and characterizing ultra-pure, rare-earth doped ZIBLAN (ZrF{sub 4}-InF{sub 3}BaF{sub 2}-LaF{sub 3}-AlF{sub 3}-NaF) glass capable of laser refrigeration. The glass was produced from fluorides which were purified and subsequently treated with hydrofluoric gas at elevated temperatures to remove impurities before glass formation. Several Yb3 +-doped samples were studied with degrees of purity and composition with successive iterations producing an improved material. We have developed a non-invasive, spectroscopic technique, two band differential luminescence thermometry (TBDLT), to evaluate the intrinsic quality of the ytterbium doped ZIBLAN used for laser cooling experiments. TBDLT measures local temperature changesmore » within an illuminated volume resulting solely from changes in the relative thermal population of the excited state levels. This TBDLT technique utilizes two commercially available band pass filters to select and integrate the 'difference regions' of interest in the luminescence spectra. The goal is to determine the minimum temperature to which the ytterbium sample can cool on the local scale, unphased by surface heating. This temperature where heating and cooling are exactly balanced is the zero crossing temperature (ZCT) and can be used as a measure for the presence of impurities and the overall quality of the laser cooling material. Overall, favorable results were obtained from 1 % Yb3+-doped glass, indicating our glasses are desirable for laser refrigeration.« less

  20. Biophysical evaluation of fractional laser skin resurfacing with an Er:YSGG laser device in Japanese skin.

    PubMed

    Kimura, Utako; Kinoshita, Ayako; Osawa, Aki; Negi, Osamu; Haruna, Kunitaka; Mizuno, Yuki; Suga, Yasushi

    2012-05-01

    Ablative fractional laser skin resurfacing (FLSR) has recently been used for the amelioration of acne scars, and previous studies have shown clinical effectiveness. Despite its extensive use, few studies have focused on the associated changes in biophysical properties of the epidermis. Herein, we evaluate transepidermal water loss, sebum levels, skin hydration, and skin elasticity, following FLSR treatments with an Er:YSGG laser device (Pearl FractionalTM, Cutera Inc., Brisbane, CA), employing non-invasive measurements. Five Japanese patients with facial acne scars underwent one FLSR session. Some acne scars appeared to become less obvious as a consequence of the treatment. All patients were aware of a feeling of skin tightness in treated areas. Objective measurements on the lower lateral angle of the eye and on the inner cheeks were evaluated at baseline and at 3 days, 1 week, and 4 weeks after FLSR. Transepidermal water loss showed a significant two-fold (100%) increase at day 3, but had returned to almost the baseline level at week 4 in both areas. Sebum secretion showed a 50% increase at day 3, but had returned to the baseline level after day 7. Skin hydration showed a significant decrease at day 3, but had returned to the baseline level by day 7, and showed significant improvement at the end of the study. Skin elasticity (R2) was still at baseline on day 3, but showed some improvement--an increase of at least 30%--at the end of the study. Based on our findings, we believe that FLSR should be performed no more than once a month to allow sufficient time for the damaged skin to recover its barrier function in most areas of the face.

  1. Experimental evaluation of penetration capabilities of a Geiger-mode APD array laser radar system

    NASA Astrophysics Data System (ADS)

    Jonsson, Per; Tulldahl, Michael; Hedborg, Julia; Henriksson, Markus; Sjöqvist, Lars

    2017-10-01

    Laser radar 3D imaging has the potential to improve target recognition in many scenarios. One case that is challenging for most optical sensors is to recognize targets hidden in vegetation or behind camouflage. The range resolution of timeof- flight 3D sensors allows segmentation of obscuration and target if the surfaces are separated far enough so that they can be resolved as two distances. Systems based on time-correlated single-photon counting (TCSPC) have the potential to resolve surfaces closer to each other compared to laser radar systems based on proportional mode detection technologies and is therefore especially interesting. Photon counting detection is commonly performed with Geigermode Avalanche Photodiodes (GmAPD) that have the disadvantage that they can only detect one photon per laser pulse per pixel. A strong return from an obscuring object may saturate the detector and thus limit the possibility to detect the hidden target even if photons from the target reach the detector. The operational range where good foliage penetration is observed is therefore relatively narrow for GmAPD systems. In this paper we investigate the penetration capability through semi-transparent surfaces for a laser radar with a 128×32 pixel GmAPD array and a 1542 nm wavelength laser operating at a pulse repetition frequency of 90 kHz. In the evaluation a screen was placed behind different canvases with varying transmissions and the detected signals from the surfaces for different laser intensities were measured. The maximum return from the second surface occurs when the total detection probability is around 0.65-0.75 per pulse. At higher laser excitation power the signal from the second surface decreases. To optimize the foliage penetration capability it is thus necessary to adaptively control the laser power to keep the returned signal within this region. In addition to the experimental results, simulations to study the influence of the pulse energy on penetration through

  2. Un nouveau cristal laser largement accordable le BOYS dopé à l'ytterbium

    NASA Astrophysics Data System (ADS)

    Chénais, S.; Druon, F.; Balembois, F.; Georges, P.; Gaumé, R.; Aka, G.; Viana, B.; Vivien, D.

    2002-06-01

    Nous avons étudié les performances laser en pompage par diode de puissance d'un nouveau cristal : le Sr3Y(BO3)3 (acronyme : BOYS), dopé à l'ytterbium. Son spectre d'émission particulièrement large en fait un matériau particulièrement prometteur pour la réalisation de lasers femtosecondes directement pompés par diode. Ses performances ont été comparées à celles d'un verre phosphate ainsi qu'à celles du cristal d' Yb:GdCOB dans les mêmes conditions. Nous démontrons que, tant du point de vue de l'efficacité laser que de la tenue aux fortes puissances, GdCOB et BOYS sont supérieurs au verre ; le BOYS est de surcroît plus accordable (sur 50 nm), mais son comportement thermique limite a priori son usage à des puissances de pompe modérées.

  3. Site evaluation for laser satellite-tracking stations

    NASA Technical Reports Server (NTRS)

    Mao, N. H.; Mohr, P. A.

    1976-01-01

    Twenty-six locations for potential laser satellite-tracking stations, four of them actually already occupied in this role, are reviewed in terms of their known local and regional geology and geophysics. The sites are also considered briefly in terms of weather and operational factors. Fifteen of the sites qualify as suitable for a stable station whose motions are likely to reflect only gross plate motion. The others, including two of the present laser station sites (Arequipa and Athens), fail to qualify unless extra monitoring schemes can be included, such as precise geodetic surveying of ground deformation.

  4. Caracterisation environnementale des emissions atmospheriques d'une source fixe et creation d'un outil de gestion dynamique =

    NASA Astrophysics Data System (ADS)

    Fournier, Marie-Claude

    Une caracterisation des emissions atmospheriques provenant des sources fixes en operation, alimentees au gaz et a l'huile legere, a ete conduite aux installations visees des sites no.1 et no.2. La caracterisation et les calculs theoriques des emissions atmospheriques aux installations des sites no.1 et no.2 presentent des resultats qui sont en dessous des valeurs reglementaires pour des conditions d'operation normales en periode hivernale et par consequent, a de plus fortes demandes energetiques. Ainsi, pour une demande energetique plus basse, le taux de contaminants dans les emissions atmospheriques pourrait egalement etre en dessous des reglementations municipales et provinciales en vigueur. Dans la perspective d'une nouvelle reglementation provinciale, dont les termes sont discutes depuis 2005, il serait souhaitable que le proprietaire des infrastructures visees participe aux echanges avec le Ministere du Developpement Durable, de l'Environnement et des Parcs (MDDEP) du Quebec. En effet, meme si le principe de droit acquis permettrait d'eviter d'etre assujetti a la nouvelle reglementation, l'application de ce type de principe ne s'inscrit pas dans ceux d'un developpement durable. L'âge avance des installations etudiees implique la planification d'un entretien rigoureux afin d'assurer les conditions optimales de combustion en fonction du type de combustible. Des tests de combustion sur une base reguliere sont donc recommandes. Afin de supporter le processus de suivi et d'evaluation de la performance environnementale des sources fixes, un outil d'aide a la gestion de l'information environnementale a ete developpe. Dans ce contexte, la poursuite du developpement d'un outil d'aide a la gestion de l'information environnementale faciliterait non seulement le travail des personnes affectees aux inventaires annuels mais egalement le processus de communication entre les differents acteurs concernes tant intra- qu'inter-etablissement. Cet outil serait egalement un bon

  5. Evaluating platelet aggregation dynamics from laser speckle fluctuations

    PubMed Central

    Hajjarian, Zeinab; Tshikudi, Diane M.; Nadkarni, Seemantini K.

    2017-01-01

    Platelets are key to maintaining hemostasis and impaired platelet aggregation could lead to hemorrhage or thrombosis. We report a new approach that exploits laser speckle intensity fluctuations, emanated from a drop of platelet-rich-plasma (PRP), to profile aggregation. Speckle fluctuation rate is quantified by the speckle intensity autocorrelation, g2(t), from which the aggregate size is deduced. We first apply this approach to evaluate polystyrene bead aggregation, triggered by salt. Next, we assess dose-dependent platelet aggregation and inhibition in human PRP spiked with adenosine diphosphate and clopidogrel. Additional spatio-temporal speckle analyses yield 2-dimensional maps of particle displacements to visualize platelet aggregate foci within minutes and quantify aggregation dynamics. These findings demonstrate the unique opportunity for assessing platelet health within minutes for diagnosing bleeding disorders and monitoring anti-platelet therapies. PMID:28717586

  6. Laser ablation of hard tissue: correlation between the laser beam parameters and the post-ablative tissue characteristics

    NASA Astrophysics Data System (ADS)

    Serafetinides, Alexandros A.; Makropoulou, Mersini I.; Khabbaz, Maruan

    2003-11-01

    Hard dental tissue laser applications, such as preventive treatment, laser diagnosis of caries, laser etching of enamel, laser decay removal and cavity preparation, and more recently use of the laser light to enlarge the root canal during the endodontic therapy, have been investigated for in vitro and in vivo applications. Post-ablative surface characteristics, e.g. degree of charring, cracks and other surface deformation, can be evaluated using scanning electron microscopy. The experimental data are discussed in relevance with the laser beam characteristics, e.g. pulse duration, beam profile, and the beam delivery systems employed. Techniques based on the laser illumination of the dental tissues and the subsequent evaluation of the scattered fluorescent light will be a valuable tool in early diagnosis of tooth diseases, as carious dentin or enamel. The laser induced autofluorescence signal of healthy dentin is much stronger than that of the carious dentin. However, a better understanding of the transmission patterns of laser light in teeth, for both diagnosis and therapy is needed, before the laser procedures can be used in a clinical environment.

  7. Laser safety research and modeling for high-energy laser systems

    NASA Astrophysics Data System (ADS)

    Smith, Peter A.; Montes de Oca, Cecilia I.; Kennedy, Paul K.; Keppler, Kenneth S.

    2002-06-01

    The Department of Defense has an increasing number of high-energy laser weapons programs with the potential to mature in the not too distant future. However, as laser systems with increasingly higher energies are developed, the difficulty of the laser safety problem increases proportionally, and presents unique safety challenges. The hazard distance for the direct beam can be in the order of thousands of miles, and radiation reflected from the target may also be hazardous over long distances. This paper details the Air Force Research Laboratory/Optical Radiation Branch (AFRL/HEDO) High-Energy Laser (HEL) safety program, which has been developed to support DOD HEL programs by providing critical capability and knowledge with respect to laser safety. The overall aim of the program is to develop and demonstrate technologies that permit safe testing, deployment and use of high-energy laser weapons. The program spans the range of applicable technologies, including evaluation of the biological effects of high-energy laser systems, development and validation of laser hazard assessment tools, and development of appropriate eye protection for those at risk.

  8. Des recommandations probantes pour surveiller l’innocuité des antipsychotiques de deuxième génération chez les enfants et les adolescents

    PubMed Central

    Pringsheim, Tamara; Panagiotopoulos, Constadina; Davidson, Jana; Ho, Josephine

    2012-01-01

    HISTORIQUE : Au Canada, l’utilisation d’antipsychotiques, notamment les antipsychotiques de deuxième génération (ADG), a augmenté de façon considérable depuis cinq ans chez les enfants ayant des troubles de santé mentale. Ces médicaments ont le potentiel de causer de graves complications métaboliques et neurologiques lorsqu’on les utilise de manière chronique. OBJECTIF : Synthétiser les données probantes relatives aux effets secondaires métaboliques et neurologiques précis associés à l’usage d’ADG chez les enfants et fournir des recommandations probantes sur la surveillance de ces effets secondaires. MÉTHODOLOGIE : Les auteurs ont procédé à une analyse systématique des essais cliniques contrôlés des ADG auprès d’enfants. Ils ont fait des recommandations à l’égard de la surveillance de l’innocuité des ADG d’après un modèle de classification fondé sur le système GRADE (système de notation de l’évaluation et de l’élaboration des recommandations). Lorsque les données probantes n’étaient pas suffisantes, ils fondaient leurs recommandations sur le consensus et l’avis d’experts. Un groupe consensuel multidisciplinaire a analysé toutes les données probantes pertinentes et est parvenu à un consensus à l’égard des recommandations. RÉSULTATS : Les recommandations probantes portant sur la surveillance de l’innocuité des ADG figurent dans les présentes lignes directrices. Les auteurs indiquent la qualité des recommandations relatives à des examens physiques et tests de laboratoire précis à l’égard de chaque ADG à des moments déterminés. CONCLUSION : De multiples essais aléatoires et contrôlés ont permis d’évaluer l’efficacité de bon nombre des ADG utilisés pour traiter les troubles de santé mentale en pédiatrie. Toutefois, leurs avantages ne sont pas sans risques : on observe à la fois des effets secondaires métaboliques et neurologiques chez les enfants traités au moyen d

  9. Evaluation of Wavelength Detuning to Mitigate Cross-Beam Energy Transfer Using the Nike Laser

    NASA Astrophysics Data System (ADS)

    McKenty, P. W.; Marozas, J. A.; Weaver, J.; Obenschain, S. P.; Schmitt, A. J.

    2015-11-01

    Cross-beam energy transfer (CBET) has become a serious threat to the overall success of direct-drive experiments, and especially for polar-direct-drive (PDD) ignition experiments. CBET redirects incident laser light before it can be absorbed into the target, thereby degrading overall target performance. CBET is particularly detrimental over the equator of the target, which is hydrodynamically very sensitive to such losses in the PDD configuration. A promising solution uses laser wavelength detuning between beams to shift the resonance, thereby reducing the interaction cross section between them. Testing this process for direct drive is now underway at the Nike laser at the Naval Research Laboratory. Calculations evaluating the effect CBET has on the scattered-light signals indicate such an experiment will demonstrate the benefits of wavelength detuning for direct-drive implosions. Two-dimensional simulation results will be presented, predicting the effect for both spherical and cylindrical experiments. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  10. Measuring Diversity and Inclusion in Academic Medicine: The Diversity Engagement Survey (DES)

    PubMed Central

    Person, Sharina D.; Jordan, C. Greer; Allison, Jeroan J.; Fink Ogawa, Lisa M.; Castillo-Page, Laura; Conrad, Sarah; Nivet, Marc A.; Plummer, Deborah L.

    2018-01-01

    Purpose To produce a physician and scientific workforce capable of delivering high quality, culturally competent health care and research, academic medical centers must assess their capacity for diversity and inclusion and respond to identified opportunities. Thus, the Diversity Engagement Survey (DES) is presented as a diagnostic and benchmarking tool. Method The 22-item DES connects workforce engagement theory with inclusion and diversity constructs. Face and content validity were established based on decades of previous work to promote institutional diversity. The survey was pilot tested at a single academic medical center and subsequently administered at 13 additional academic medical centers. Cronbach alphas assessed internal consistency and Confirmatory Factor Analysis (CFA) established construct validity. Criterion validity was assessed by observed separation in scores for groups traditionally recognized to have less workforce engagement. Results The sample consisted of 13,694 individuals at 14 medical schools from across the U.S. who responded to the survey administered between 2011– 2012. The Cronbach alphas for inclusion and engagement factors (range: 0.68 to 0.85), CFA fit indices, and item correlations with latent constructs, indicated an acceptable model fit and that questions measured the intended concepts. DES scores clearly distinguished higher and lower performing institutions. The DES detected important disparities for black, women, and those who did not have heterosexual orientation. Conclusions This study demonstrated that the DES is a reliable and valid instrument for internal assessment and evaluation or external benchmarking of institutional progress in building inclusion and engagement. PMID:26466376

  11. Histological evaluation of vertical laser channels from ablative fractional resurfacing: an ex vivo pig skin model.

    PubMed

    Skovbølling Haak, Christina; Illes, Monica; Paasch, Uwe; Hædersdal, Merete

    2011-07-01

    Ablative fractional resurfacing (AFR) represents a new treatment potential for various skin conditions and new laser devices are being introduced. It is important to gain information about the impact of laser settings on the dimensions of the created laser channels for obtaining a safe and efficient treatment outcome. The aim of this study was to establish a standard model to document the histological tissue damage profiles after AFR and to test a new laser device at diverse settings. Ex vivo abdominal pig skin was treated with a MedArt 620, prototype fractional carbon dioxide (CO(2)) laser (Medart, Hvidovre, Denmark) delivering single microbeams (MB) with a spot size of 165 μm. By using a constant pulse duration of 2 ms, intensities of 1-18 W, single and 2-4 stacked pulses, energies were delivered in a range from 2-144 mJ/MB. Histological evaluations included 3-4 high-quality histological measurements for each laser setting (n = 28). AFR created cone-shaped laser channels. Ablation depths varied from reaching the superficial dermis (2 mJ, median 41 μm) to approaching the subcutaneous fat (144 mJ, median 1,943 μm) and correlated to the applied energy levels in an approximate linear relation (r(2) = 0.84, p < 0.001). The dermal ablation width increased slightly within the energy range of 4-144 mJ (median 163 μm). The thickness of the coagulation zone reached a plateau around 65 μm at energies levels above 16 mJ. The calculated volumes of ablated tissue increased with increasing energies. We suggest this ex vivo pig skin model to characterize AFR laser channels histologically.

  12. Influence du comportement des accompagnants sur le vécu des patients admis pour hémorragies digestives hautes au CHU campus de Lomé (Togo)

    PubMed Central

    Bagny, Aklesso; Dusabe, Angelique; Bouglouga, Oumboma; Lawson-ananisoh, Mawuli Late; Kaaga, Yeba Laconi; Djibril, Mohaman Awalou; Soedje, Kokou Mensah; Dassa, Simliwa Kolou; Redah, Datouda

    2014-01-01

    Introduction L'hémorragie digestive haute est une urgence, qui constitue souvent pour les patients un danger mortel suscitant inquiétude et agitation. Dans cet état, le patient dépend de ses accompagnants pour ses soins et pour honorer le traitement; mais souvent, il a été observé une discordance entre l'urgence et les comportements des accompagnants. Le but de cette étude était de décrire les facteurs socioéconomiques et psychologiques pouvant influencer les comportements des accompagnants des patients admis pour HDH, estimer l'indice de relation entre ces comportements et les facteurs associés d'une part et le vécu des patients admis pour HDH d'autre part. Méthodes Il s'agit d'une étude prospective menée de Septembre 2010 à Juin 2011 (soit 10 mois). Nous avions utilisé l'entretien semi-dirigé et l'observation directe pour collecter nos données, ces dernières avaient été traitées par les méthodes statistiques et d'analyse de contenu. Résultats Dans la présente étude, les comportements des accompagnants des patients admis pour HDH sont en majorité marqués par l'abandon (84%) et le manque de sollicitude (80,2%). Ces comportements sont souvent stimulés par les facteurs socioéconomiques tels que les difficultés économiques (83,2%), des conflits intrafamiliaux (85,1%) et des représentations (maladie incurable ou envoûtement) de la maladie par les accompagnants (73,3%) des cas. Quant aux patients, ils vivent ces comportements comme étant des menaces de mort ou des rejets (77,20%) et comme étant une dévalorisation ou une humiliation de la part de leurs accompagnants (70,30%). Les résultats confirment l'existence de lien significatif entre les comportements des accompagnants et les facteurs socio économiques, entre les comportements des accompagnants et des facteurs psychologiques, et entre le vécu des patients admis pour l'HDH et les comportements des accompagnants. Conclusion Des études ultérieures devraient aborder les points

  13. Transurethral vaporesection of prostate: diode laser or thulium laser?

    PubMed

    Tan, Xinji; Zhang, Xiaobo; Li, Dongjie; Chen, Xiong; Dai, Yuanqing; Gu, Jie; Chen, Mingquan; Hu, Sheng; Bai, Yao; Ning, Yu

    2018-05-01

    This study compared the safety and effectiveness of the diode laser and thulium laser during prostate transurethral vaporesection for treating benign prostate hyperplasia (BPH). We retrospectively analyzed 205 patients with BPH who underwent a diode laser or thulium laser technique for prostate transurethral vaporesection from June 2016 to June 2017 and who were followed up for 3 months. Baseline characteristics of the patients, perioperative data, postoperative outcomes, and complications were compared. We also assessed the International Prostate Symptom Score (IPSS), quality of life (QoL), maximum flow rate (Q max ), average flow rate (AFR), and postvoid residual volume (PVR) at 1 and 3 months postoperatively to evaluate the functional improvement of each group. There were no significant differences between the diode laser and thulium laser groups related to age, prostate volume, operative time, postoperative hospital stays, hospitalization costs, or perioperative data. The catheterization time was 3.5 ± 0.8 days for the diode laser group and 4.7 ± 1.8 days for the thulium laser group (p < 0.05). Each group had dramatic improvements in IPSS, QoL, Q max , AFR, and PVR compared with the preoperative values (p < 0.05), although there were no significant differences between the two groups. Use of both diode laser and thulium laser contributes to safe, effective transurethral vaporesection in patients with symptomatic BPH. Diode laser, however, is better than thulium laser for prostate transurethral vaporesection because of its shorter catheterization time. The choice of surgical approach is more important than the choice of laser types during clinical decision making for transurethral laser prostatectomy.

  14. CO2 and diode laser for excisional biopsies of oral mucosal lesions. A pilot study evaluating clinical and histopathological parameters.

    PubMed

    Suter, Valérie G A; Altermatt, Hans Jörg; Sendi, Pedram; Mettraux, Gérald; Bornstein, Michael M

    2010-01-01

    The present pilot study evaluates the histopathological characteristics and suitability of CO2 and diode lasers for performing excisional biopsies in the buccal mucosa with special emphasis on the extent of the thermal damage zone created. 15 patients agreed to undergo surgical removal of their fibrous hyperplasias with a laser. These patients were randomly assigned to one diode or two CO2 laser groups. The CO2 laser was used in a continuous wave mode (cw) with a power of 5 W (Watts), and in a pulsed char-free mode (cf). Power settings for the diode laser were 5.12 W in a pulsed mode. The thermal damage zone of the three lasers and intraoperative and postoperative complications were assessed and compared. The collateral thermal damage zone on the borders of the excisional biopsies was significantly smaller with the CO, laser for both settings tested compared to the diode laser regarding values in pm or histopathological index scores. The only intraoperative complication encountered was bleeding, which had to be controlled with electrocauterization. No postoperative complications occurred in any of the three groups. The CO2 laser seems to be appropriate for excisional biopsies of benign oral mucosal lesions. The CO2 laser offers clear advantages in terms of smaller thermal damage zones over the diode laser. More study participants are needed to demonstrate potential differences between the two different CO2 laser settings tested.

  15. Scramjet Thermal Management (Tenue thermique des superstatoreacteurs)

    DTIC Science & Technology

    2010-09-01

    RTO-EN-AVT-185 13 - 1 Scramjet Thermal Management (Tenue thermique des superstatoréacteurs) Marc BOUCHEZ MBDA France Rond-point Marcel...SPEED PROPULSION: ENGINE DESIGN – INTEGRATION AND THERMAL MANAGEMENT” fut donné à l’Institut Von Karman en septembre 2010 et à l’Université Wright de ...Dayton (Ohio, USA) en décembre 2010. Le présent cours aborde la tenue thermique. Il est basé sur des informations publiées, et des détails

  16. Robotic Laser Coating Removal System

    DTIC Science & Technology

    2008-08-01

    9 3.2 SELECTION OF TEST PLATFORM/FACILITY .................................. 9 3.3 TEST PLATFORM/FACILITY HISTORY...lasers are 4 efficient in converting electrical energy to coherent radiation and, thus, have widespread industrial use. In order to select an...completion of this evaluation a 6 kW CO2 laser from Rofin-Sinar was selected for use in the RLCRS. This laser provided the highest quality laser

  17. Classification of 13 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Macaulay, E.; Allam, S.; Tucker, D.; Asorey, J.; Davis, T. M.; Kremlin, A.; Lewis, G. F.; Lidman, C.; Martini, P.; Sommer, N. E.; Tucker, B. E.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Moller, A.; Muthukrishna, D. R.; Yuan, F.; Zhang, B.; Hinton, S.; Parkinson, D.; Uddin, S.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Nichol, R.; Maartens, R.; Childress, M.; Prajs, S.; Smith, M.; Sullivan, M.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.

    2018-01-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  18. Classification of 26 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Calcino, J.; Davis, T. M.; Hoormann, J. K.; Asorey, J.; Glazebrook, K.; Carnero, A.; Lidman, C.; Martini, P.; Moller, A.; Sommer, N. E.; Sharp, R.; Tucker, B. E.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Muthukrishna, D. R.; Yuan, F.; Zhang, B.; Hinton, S.; Lewis, G. F.; Parkinson, D.; Uddin, S.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Macaulay, E.; Nichol, R.; Maartens, R.; Childress, M.; Prajs, S.; Smith, M.; Sullivan, M.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.

    2018-01-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  19. Classification of 25 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Calcino, J.; Davis, T. M.; Hoormann, J. K.; Asorey, J.; Glazebrook, K.; Carnero, A.; Lidman, C.; Martini, P.; Moller, A.; Sommer, N. E.; Sharp, R.; Tucker, B. E.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Muthukrishna, D. R.; Yuan, F.; Zhang, B.; Hinton, S.; Lewis, G. F.; Parkinson, D.; Uddin, S.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Macaulay, E.; Nichol, R.; Maartens, R.; Childress, M.; Prajs, S.; Smith, M.; Sullivan, M.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.

    2018-01-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  20. Classification of 18 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Swann, E. S.; Lewis, G. F.; Lidman, C.; Panther, F. H.; Sharp, R.; Sommer, N. E.; Tucker, B. E.; Muthukrishna, D.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Moller, A. R.; Yuan, F.; Zhang, B.; Davis, T. M.; Hinton, S.; Asorey, J.; Uddin, S.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Macaulay, E.; Nichol, R.; Maartens, R.; Childress, M.; Prajs, S.; Smith, M.; Sullivan, M.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.

    2018-06-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  1. Classification of 17 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Muthukrishna, D.; Sharp, R. G.; Tucker, B. E.; Moller, A.; Sommer, N. E.; Asorey, J.; Lewis, G. F.; Lidman, C.; Mould, J.; Macaulay, E.; Maartens, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Yuan, F.; Zhang, B.; Davis, T. M.; Hinton, S.; Parkinson, D.; Uddin, S.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Nichol, R.; Childress, M.; Prajs, S.; Smith, M.; Sullivan, M.

    2017-09-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  2. The clinical effectiveness and cost-effectiveness of fractional CO2 laser in acne scars and skin rejuvenation: A meta-analysis and economic evaluation.

    PubMed

    Ansari, Fereshteh; Sadeghi-Ghyassi, Fatemeh; Yaaghoobian, Barmak

    2018-01-31

    Fractional CO 2 has many indications in medicine including in treatment of acne scars and rejuvenation. The aim of this study was to evaluate the safety, efficacy, and cost-effectiveness of Fractional CO 2 Laser in comparison with other methods of rejuvenation and acne scar treatment. Several databases including Medline, OVID, EMBASE, CINHAL, SCOPUS, Web of science, CRD, and Cochrane were searched. After conducting the search and evaluation of selected publications, critical appraisal was done and eligible studies were accepted for inclusion in the systematic review. From 2667 identified publications two of the trials were eligible. The effectiveness and complications of Fractional CO 2 laser were comparable with Er:YAG but Fractional CO 2 laser was 14.7% (p = 0.01) more effective than Q-Switched ND:YAG laser. Cost affectivity of this method was the same as other alternative lasers. In conclusion Fractional CO 2 laser is an effective and safe method for curing of several kinds of skin diseases. Nevertheless there was not sufficient evidence to support its advantage. This device has equal or lower price in comparison to competent technologies except for the non- fractional ablative CO 2 laser that has the same or lower price and comparable effects.

  3. Influence des défauts de la structure du verre sur la résistance mécanique des fibres optiques

    NASA Astrophysics Data System (ADS)

    Chmel, A.; Baptizmanski, V. V.; Kharshak, A. A.

    1992-12-01

    For silica (pure and doped) optical fibers prepared from preforms irradiated by thermal neutrons and Ar^+ ions, the measurements of lifetime under transverse stress were carried out. It is found that the neutron bombardment leads to decrease of the lifetime and the strength of fiber while the ion implantation results in increasing of these parameters. The influence of particle irradiation on the glass strength is explained by the generation of structural defects which were observed by the infrared an Raman spectroscopy methods. The direction of the change of mechanical properties of fibers is determined by the type of defects and their distribution in the cross-section of fiber. Des préformes de fibres optiques de silice ont été exposées à un bombardement par des faisceaux de neutrons thermiques et d'ions Ar^+ à énergie de 40 keV afin d'engendrer des défauts de la structure respectivement dans le volume ou dans la couche superficielle des échantillons. Les fibres obtenues des préformes irradiées et non irradiées ont été mises en charge de flexion. On a déterminé leur temps de rupture sous diverses contraintes de traction sur la surface extérieure de la fibre en flexion. On a observé une diminution du temps de rupture des fibres après le bombardement neutronique et une augmentation après l'implantation ionique. L'analyse de la nature des défauts en faisant appel à la spectroscopie infrarouge et Raman a fait ressortir que l'irradiation aux ions entraînait essentiellement des liaisons chimiques dans une fine couche superficielle de l'échantillon alors que l'irradiation aux neutrons occasionnait une déformation des zones du réseau silicique dans toute la section de la préforme et de la fibre. L'amélioration de la résistance mécanique s'explique par une augmentation de la mobilité des éléments structuraux de la matrice de verre par suite d'une rupture partielle des liaisons chimiques et sa diminution par l'apparition de concentrateurs

  4. Ex vivo evaluation of super pulse diode laser system with smart temperature feedback for contact soft-tissue surgery

    NASA Astrophysics Data System (ADS)

    Yaroslavsky, Ilya; Boutoussov, Dmitri; Vybornov, Alexander; Perchuk, Igor; Meleshkevich, Val; Altshuler, Gregory

    2018-02-01

    Until recently, Laser Diodes (LD) have been limited in their ability to deliver high peak power levels, which, in turn, limited their clinical capabilities. New technological developments made possible advent of "super pulse" LD (SPLD). Moreover, advanced means of smart thermal feedback enable precise control of laser power, thus ensuring safe and optimally efficacious application. In this work, we have evaluated a prototype SPLD system ex vivo. The device provided up to 25 W average and up to 150 W pulse power at 940 nm wavelength. The laser was operated in the thermal feedback-controlled mode, where power of the laser was varied automatically as a function of real-time thermal feedback to maintain constant tip temperature. The system was also equipped with a fiber tip initiated with advanced TiO2 /tungsten technique. Evaluation methods were designed to assess: 1) Speed and depth of cutting; 2) Dimensions of coagulative margin. The SPLD system was compared with industry-leading conventional diode and CO2 devices. The results indicate that the SPLD system provides increase in speed of controlled cutting by a factor of >2 in comparison with the conventional diode laser and approaching that of CO2 device. The produced ratio of the depth of cut to the thermal damage margin was significantly higher than conventional diodes and close to that of the CO2 system, suggesting optimal hemostasis conditions. SPLD technology with real-time temperature control has a potential for creating a new standard of care in the field of precision soft tissue surgery.

  5. Etude de la dynamique des porteurs dans des nanofils de silicium par spectroscopie terahertz

    NASA Astrophysics Data System (ADS)

    Beaudoin, Alexandre

    Ce memoire presente une etude des proprietes de conduction electrique et de la dynamique temporelle des porteurs de charges dans des nanofils de silicium sondes par rayonnement terahertz. Les cas de nanofils de silicium non intentionnellement dopes et dopes type n sont compares pour differentes configurations du montage experimental. Les mesures de spectroscopie terahertz en transmission montre qu'il est possible de detecter la presence de dopants dans les nanofils via leur absorption du rayonnement terahertz (˜ 1--12 meV). Les difficultes de modelisation de la transmission d'une impulsion electromagnetique dans un systeme de nanofils sont egalement discutees. La detection differentielle, une modification au systeme de spectroscopie terahertz, est testee et ses performances sont comparees au montage de caracterisation standard. Les instructions et des recommendations pour la mise en place de ce type de mesure sont incluses. Les resultats d'une experience de pompe optique-sonde terahertz sont egalement presentes. Dans cette experience, les porteurs de charge temporairement crees suite a l'absorption de la pompe optique (lambda ˜ 800 nm) dans les nanofils (les photoporteurs) s'ajoutent aux porteurs initialement presents et augmentent done l'absorption du rayonnement terahertz. Premierement, l'anisotropie de l'absorption terahertz et de la pompe optique par les nanofils est demontree. Deuxiemement, le temps de recombinaison des photoporteurs est etudie en fonction du nombre de photoporteurs injectes. Une hypothese expliquant les comportements observes pour les nanofils non-dopes et dopes-n est presentee. Troisiemement, la photoconductivite est extraite pour les nanofils non-dopes et dopes-n sur une plage de 0.5 a 2 THz. Un lissage sur la photoconductivite permet d'estimer le nombre de dopants dans les nanofils dopes-n. Mots-cles: nanofil, silicium, terahertz, conductivite, spectroscopie, photoconductivite.

  6. Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model

    PubMed Central

    Stecher, David; Bronkers, Glenn; Noest, Jappe O.T.; Tulleken, Cornelis A.F.; Hoefer, Imo E.; van Herwerden, Lex A.; Pasterkamp, Gerard; Buijsrogge, Marc P.

    2014-01-01

    To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser catheter laser-punches the opening of the anastomosis. Consequently, owing to the complete nonocclusive anastomosis construction, coronary conditioning (i.e., occluding or shunting) is not necessary, in contrast to the conventional anastomotic technique, hence simplifying the off-pump bypass procedure. Prior to clinical application in coronary artery bypass grafting, the safety and quality of this novel connector will be evaluated in a long-term experimental porcine off-pump coronary artery bypass (OPCAB) study. In this paper, we describe how to evaluate the coronary anastomosis in the porcine OPCAB model using various techniques to assess its quality. Representative results are summarized and visually demonstrated. PMID:25490000

  7. The pulsed dye laser versus the Q-switched Nd:YAG laser in laser-induced shock-wave lithotripsy.

    PubMed

    Thomas, S; Pensel, J; Engelhardt, R; Meyer, W; Hofstetter, A G

    1988-01-01

    To date, there are two fairly well-established alternatives for laser-induced shock-wave lithotripsy in clinical practice. The Q-switched Nd:YAG laser is distinguished by the high-stone selectivity of its coupler systems. The necessity of a coupler system and its fairly small conversion rate of light energy into mechanical energy present serious drawbacks. Furthermore, the minimal outer diameter of the transmission system is 1.8 mm. The pulsed-dye laser can be used with a highly flexible and uncomplicated 200-micron fiber. However, the laser system itself is more complicated than the Q-switched Nd:YAG laser and requires a great deal of maintenance. Biological evaluation of damage caused by direct irradiation shows that both laser systems produce minor damage of different degrees. YAG laser lithotripsy with the optomechanical coupler was assessed in 31 patients with ureteral calculi. The instability and limited effectiveness of the fiber application system necessitated auxiliary lithotripsy methods in 14 cases. Dye-laser lithotripsy is currently being tested in clinical application. Further development, such as systems for blind application or electronic feedback mechanisms to limit adverse tissue effects, have yet to be optimized. Nevertheless, laser-induced shock-wave lithotripsy has the potential to become a standard procedure in the endourologic management of stone disease.

  8. Unique low-molecular-weight lignin with high purity extracted from wood by deep eutectic solvents (DES): a source of lignin for valorization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarez-Vasco, Carlos; Ma, Ruoshui; Quintero, Melissa

    This paper reports a new method of applying Deep Eutectic Solvents (DES) for extracting lignin from woody biomass with high yield and high purity. DES mixtures prepared from Choline Chloride (ChCl) and four hydrogen-bond donors–acetic acid, lactic acid, levulinic acid and glycerol–were evaluated for treatment of hardwood (poplar) and softwood (D. fir). It was found that these DES treatments can selectively extract a significant amount of lignin from wood with high yields: 78% from poplar and 58% from D. fir. The extracted lignin has high purity (95%) with unique structural properties. We discover that DES can selectively cleave ether linkagesmore » in wood lignin and facilitate lignin removal from wood. The mechanism of DES cleavage of ether bonds between phenylpropane units was investigated. The results from this study demonstrate that DES is a promising solvent for wood delignification and the production of a new source of lignin with promising potential applications.« less

  9. Anorexia in hemodialysis patients: the possible role of des-acyl ghrelin.

    PubMed

    Muscaritoli, Maurizio; Molfino, Alessio; Chiappini, Maria Grazia; Laviano, Alessandro; Ammann, Thomas; Spinsanti, Paola; Melchiorri, Daniela; Inui, Akio; Alegiani, Filippo; Rossi Fanelli, Filippo

    2007-01-01

    Anorexia is frequently found in end-stage renal disease and is a reliable predictor of morbidity and mortality in hemodialysis (HD) patients. The pathogenesis of anorexia is complex and the appetite-modulating hormone ghrelin could be involved. Two forms of circulating ghrelin have been described: acylated ghrelin (<10% of circulating ghrelin) which promotes food intake, and des-acyl ghrelin which induces a negative energy balance. The aim of this cross-sectional study is to clarify whether anorexia and body weight change in HD patients relate to plasma des-acyl ghrelin levels. 34 HD patients and 15 healthy controls were studied. The presence of anorexia was assessed by a questionnaire. Serum des-acyl ghrelin was measured in HD patients and in 15 body mass index-, sex- and age-matched controls by ELISA. Energy intake was assessed by a 3-day dietary diary, and fat-free mass (FFM) was evaluated by body impedance analysis. Data have been statistically analyzed and are presented as mean +/- SD. 14 patients (41%) were found to be anorexic, and 20 patients (59%) non-anorexic. Energy intake (kcal/day) was significantly lower in anorexic than in non-anorexic patients (1,682 +/- 241 vs. 1,972.50 +/- 490; p < 0.05). FFM (%) was lower in anorexic than in non-anorexic patients (65.8 +/- 4.4 vs. 70.9 +/- 8.7; p = 0.05). Plasma des-acyl ghrelin levels (fmol/ml) were significantly higher in HD patients than in controls (214.88 +/- 154.24 vs. 128.93 +/- 51.07; p < 0.05), and in anorexic HD patients than in non-anorexic (301.7 +/- 162.4 vs. 159.1 +/- 115.5; p < 0.01). Anorexia is highly prevalent among HD patients and des-acyl ghrelin could be involved in its pathogenesis. Copyright 2007 S. Karger AG, Basel.

  10. Methodes iteratives paralleles: Applications en neutronique et en mecanique des fluides

    NASA Astrophysics Data System (ADS)

    Qaddouri, Abdessamad

    Dans cette these, le calcul parallele est applique successivement a la neutronique et a la mecanique des fluides. Dans chacune de ces deux applications, des methodes iteratives sont utilisees pour resoudre le systeme d'equations algebriques resultant de la discretisation des equations du probleme physique. Dans le probleme de neutronique, le calcul des matrices des probabilites de collision (PC) ainsi qu'un schema iteratif multigroupe utilisant une methode inverse de puissance sont parallelises. Dans le probleme de mecanique des fluides, un code d'elements finis utilisant un algorithme iteratif du type GMRES preconditionne est parallelise. Cette these est presentee sous forme de six articles suivis d'une conclusion. Les cinq premiers articles traitent des applications en neutronique, articles qui representent l'evolution de notre travail dans ce domaine. Cette evolution passe par un calcul parallele des matrices des PC et un algorithme multigroupe parallele teste sur un probleme unidimensionnel (article 1), puis par deux algorithmes paralleles l'un mutiregion l'autre multigroupe, testes sur des problemes bidimensionnels (articles 2--3). Ces deux premieres etapes sont suivies par l'application de deux techniques d'acceleration, le rebalancement neutronique et la minimisation du residu aux deux algorithmes paralleles (article 4). Finalement, on a mis en oeuvre l'algorithme multigroupe et le calcul parallele des matrices des PC sur un code de production DRAGON ou les tests sont plus realistes et peuvent etre tridimensionnels (article 5). Le sixieme article (article 6), consacre a l'application a la mecanique des fluides, traite la parallelisation d'un code d'elements finis FES ou le partitionneur de graphe METIS et la librairie PSPARSLIB sont utilises.

  11. Des Moines metropolitan area ITS strategic plan

    DOT National Transportation Integrated Search

    1998-08-19

    The Des Moines Area Metropolitan Organization (MPO) completed an early deployment study for the Des Moines metropolitan area in late 1997. The purpose of the study was to develop a strategic plan for Intelligent Transportation Systems (ITS) deploymen...

  12. Clinical Evaluation of Hair Removal Using an 810 nm Diode Laser With a Novel Scanning Device.

    PubMed

    Courtney, Erin; Goldberg, David J

    2016-11-01

    Diode lasers are often considered as the gold standard preference for hair removal due to the deep penetration and ef- fective targeting of the hair follicle. A wide variety of diode lasers are available, which can differ in terms of their parameters (such as fluence, pulse duration, repetition rate, scanner, and cooling). The objective of the study was to evaluate the safety and ef cacy of hair removal with an 810 nm novel scanning diode laser, up to six months after last treatment. A scanning 810 nm diode laser was used for axillary hair removal of 14 female patients who received 3 treatments, 4-6 weeks apart. Follow-up on hair count was conducted 3 and 6 months after last treatment and compared to baseline hair count. No unexpected or signi cant adverse events were recorded. An average hair count reduction of 72.8% after 3 months and 67.6% 6 months after the last treatment is demonstrated. The examined 810 nm diode laser was proven to be safe and effective for hair removal. Results were sustained for 6 months after last treatment. Longer follow-up data are followed for further substantiation of the clinical effect. Scanning technology can provide for potentially faster and safer treatments. J Drugs Dermatol. 2016;15(11):1330-1333..

  13. Analyse de L'ancrage des Vortex Intergrains pour le Yttrium BARYUM(2) CUIVRE(3) OXYGENE(7) Polycristallin

    NASA Astrophysics Data System (ADS)

    Fournier, Patrick

    Le Modele de l'Etat Critique Generalise (MECG) est utilise pour decrire les proprietes magnetiques et de transport du YBa_2Cu_3O _7 polycristallin. Ce modele empirique permet de relier la densite de courant critique a la densite de lignes de flux penetrant dans la region intergrain. Deux techniques de mesures sont utilisees pour caracteriser nos materiaux. La premiere consiste a mesurer le champ au centre d'un cylindre creux en fonction du champ magnetique applique pour des temperatures comprises entre 20 et 85K. En variant l'epaisseur de la paroi du cylindre creux, il est possible de suivre l'evolution des cycles d'hysteresis et de determiner des champs caracteristiques qui varient en fonction de cette dimension. En utilisant un lissage des resultats experimentaux, nous determinons J _{co}, H_ {o} et n, les parametres du MECG. La forme des cylindres, avec une longueur comparable au diametre externe, entrai ne la presence d'un champ demagnetisant qui peut etre inclus dans le modele theorique. Ceci nous permet d'evaluer la fraction du volume ecrante, f _{g}, ainsi que le facteur demagnetisant N. Nous trouvons que J_{ co}, H_{o} et f_{g} dependent de la temperature, tandis que n et N (pour une epaisseur de paroi fixe) n'en dependent pas. La deuxieme technique consiste a mesurer le courant critique de lames minces en fonction du champ applique pour differentes temperatures. Nous utilisons un montage que nous avons developpe permettant d'effectuer ces mesures en contact direct avec le liquide refrigerant, i.e. dans l'azote liquide. Nous varions la temperature du liquide en variant la pression du gaz au-dessus du bain d'azote. Cette methode nous permet de balayer des temperatures entre 65K et la temperature critique du materiau ({~ }92K). Nous effectuons le lissage des courbes de courant critique en fonction du champ applique encore a l'aide du MECG, pour a nouveau obtenir ses parametres. Pour trois echantillons avec des traitements thermiques differents, les parametres

  14. A quantitative evaluation of the L.B.W. efficiency on AISI 304 bead on plates welded under different focusing and tilted laser beam conditions

    NASA Astrophysics Data System (ADS)

    Daurelio, Giuseppe; Ludovico, Antonio D.; Lugara, M. P.; De Filippis, L. A. C.; Spera, A. M.; Rocco, S.

    2005-03-01

    The aim of this search is to evaluate the WE (Welding Efficiency) of each beads versus the different positions of the laser beam optical focus (positive or negative or zero values) respect to the work-piece surface and also versus different laser beam incidence angles (80° and 70°) by using two laser power levels (2 and 2.5 KW) and two welding speeds (3 and 6 m/min). The WE values have been reported on two DA.LU. method plots and the relate evaluations regarding the same ones as well as the recorded best parameters have been evidenced.

  15. Comparative evaluation of antimicrobial effects of Er:YAG, diode, and CO₂ lasers on titanium discs: an experimental study.

    PubMed

    Tosun, Emre; Tasar, Ferda; Strauss, Robert; Kıvanc, Dolunay Gulmez; Ungor, Cem

    2012-05-01

    This study examined carbon dioxide (CO(2); 10,600 nm), diode (808 nm), and erbium (Er):yttrium-aluminum-garnet (YAG; 2,940 nm) laser applications on Staphylococcus aureus contaminated, sandblasted, large-grit, acid-etched surface titanium discs and performed a comparative evaluation of the obtained bactericidal effects and the applicability of these effects in clinical practice. This study was carried out in 5 main groups: Er:YAG laser in very short pulse (VSP) emission mode, Er:YAG laser in short pulse (SP) emission mode, diode laser with a 320-nm fiber optic diode laser with an R24-B handpiece, and CO(2) laser. After laser irradiation, dilutions were spread on sheep blood agar plates and, after an incubation period of 24 hours, colony-forming units were counted and compared with the control group, and the bactericidal activity was assessed in relation to the colony counts. The CO(2) laser eliminated 100% of the bacteria at 6 W, 20 Hz, and a 10-ms exposure time/pulse with a 10-second application period (0.8-mm spot size). The continuous-wave diode laser eliminated 97% of the bacteria at 1 W using a 10-second application with a 320-μm optic fiber, 100% of the bacteria were killed with a 1-W, 10-second continuous-wave application with an R14-B handpiece. The Er:YAG laser eliminated 100% of the bacteria at 90 mJ and 10 Hz using a 10-second application in a superpulse mode (300-ms exposure time/pulse). The Er:YAG laser also eliminated 99% to 100% of the bacteria in VSP mode at 90 mJ and 10 Hz with a 10-second application. The results of this study show that a complete, or near complete, elimination of surface bacteria on titanium surfaces can be accomplished in vitro using a CO(2), diode, or Er:YAG laser as long as appropriate parameters are used. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. All rights reserved.

  16. Toward robot-assisted neurosurgical lasers.

    PubMed

    Motkoski, Jason W; Yang, Fang Wei; Lwu, Shelly H H; Sutherland, Garnette R

    2013-04-01

    Despite the potential increase in precision and accuracy, laser technology is not widely used in neurological surgery. This in part relates to challenges associated with the early introduction of lasers into neurosurgery. Considerable advances in laser technology have occurred, which together with robotic technology could create an ideal platform for neurosurgical application. In this study, a 980-nm contact diode laser was integrated with neuroArm. Preclinical evaluation involved partial hepatectomy, bilateral nephrectomy, splenectomy, and bilateral submandibular gland excision in a Sprague-Dawley rat model (n = 50). Total surgical time, blood loss as weight of surgical gauze before and after the procedure, and the incidence of thermal, vascular, or lethal injury were recorded and converted to an overall performance score. Thermal damage was evaluated in the liver using tissue samples stained with hematoxylin and eosin. Clinical studies involved step-wise integration of the 980-nm laser system into four neurosurgical cases. Results demonstrate the successful integration of contact laser technology into microsurgery, with and without robotic assistance. In preclinical studies, the laser improved microsurgical performance and reduced thermal damage, while neuroArm decreased intra- and intersurgeon variability. Clinical studies demonstrate dutility in meningioma resection (n = 4). Together, laser and robotic technology offered a more consistent, expedient, and precise tool for microsurgery.

  17. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study.

    PubMed

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t -test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation.

  18. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study

    PubMed Central

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    Introduction: There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. Materials and Methods: A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. Results: At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t-test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Conclusion: Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation. PMID:28539864

  19. Shear bond strength and SEM morphology evaluation of different dental adhesives to enamel prepared with ER:YAG laser

    PubMed Central

    Pires, Patrícia T.; Ferreira, João C.; Oliveira, Sofia A.; Azevedo, Álvaro F.; Dias, Walter R.; Melo, Paulo R.

    2013-01-01

    Context: Early observations of enamel surfaces prepared by erbium lasers motivated clinicians to use laser as an alternative to chemical etching. Aims: Evaluate shear bond strength (SBS) values of different dental adhesives on Erbium:Yttrium Aluminum Garnet (Er:YAG) laser prepared enamel and to evaluate possible etching patterns correlations between dental adhesives and SBS values. Subjects and Methods: One hundred bovine incisors were randomly assigned to SBS tests on enamel (n = 15) and to enamel morphology analysis (n = 5) after Er:YAG laser preparation as follows: Group I – 37% phosphoric acid (PA)+ ExciTE®; Group II – ExciTE®; Group III – AdheSE® self-etching; Group IV – FuturaBond® no-rinse. NR; Group V – Xeno® V. Teeth were treated with the adhesive systems and subjected to thermal cycling. SBS were performed in a universal testing machine at 5 mm/min. Statistical Analysis Used: One-way ANOVA and post-hoc tests (P < 0.05). For the morphology evaluation, specimens were immersed in Ethylenediamine tetraacetic acid (EDTA) and the etching pattern analyzed under Scanning Electron Microscope (SEM). Results: Mean bond strengths were Group I – 47.17 ± 1.61 MPa (type I etching pattern); Group II – 32.56 ± 1.64 MPa, Group III – 29.10 ± 1.34 MPa, Group IV – 23.32 ± 1.53 MPa (type III etching pattern); Group V – 24.43 MPa ± 1.55 (type II etching pattern). Conclusions: Different adhesive systems yielded significantly different SBSs. Acid etching significantly increased the adhesion in laser treated enamel. No differences in SBS values were obtained between AdheSE® and ExciTE® without condition with PA. FuturaBond® NR and Xeno® V showed similar SBS, which was lower in comparison to the others adhesives. No correlation between enamel surface morphology and SBS values was observed, except when PA was used. PMID:23853447

  20. DES Science Portal: Computing Photometric Redshifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gschwend, Julia

    An important challenge facing photometric surveys for cosmological purposes, such as the Dark Energy Survey (DES), is the need to produce reliable photometric redshifts (photo-z). The choice of adequate algorithms and configurations and the maintenance of an up-to-date spectroscopic database to build training sets, for example, are challenging tasks when dealing with large amounts of data that are regularly updated and constantly growing. In this paper, we present the first of a series of tools developed by DES, provided as part of the DES Science Portal, an integrated web-based data portal developed to facilitate the scientific analysis of the data,more » while ensuring the reproducibility of the analysis. We present the DES Science Portal photometric redshift tools, starting from the creation of a spectroscopic sample to training the neural network photo-z codes, to the final estimation of photo-zs for a large photometric catalog. We illustrate this operation by calculating well calibrated photo-zs for a galaxy sample extracted from the DES first year (Y1A1) data. The series of processes mentioned above is run entirely within the Portal environment, which automatically produces validation metrics, and maintains the provenance between the different steps. This system allows us to fine tune the many steps involved in the process of calculating photo-zs, making sure that we do not lose the information on the configurations and inputs of the previous processes. By matching the DES Y1A1 photometry to a spectroscopic sample, we define different training sets that we use to feed the photo-z algorithms already installed at the Portal. Finally, we validate the results under several conditions, including the case of a sample limited to i<22.5 with the color properties close to the full DES Y1A1 photometric data. This way we compare the performance of multiple methods and training configurations. The infrastructure presented here is an effcient way to test several methods

  1. Optimisation des proprietes fonctionnelles des alliages a memoire de forme suite a l'application de traitements thermomecaniques

    NASA Astrophysics Data System (ADS)

    Demers, Vincent

    L'objectif de ce projet est de determiner les conditions de laminage et la temperature de traitement thermique maximisant les proprietes fonctionnelles de l'alliage a memoire de forme Ti-Ni. Les specimens sont caracterises par des mesures de calorimetrie, de microscopie optique, de gene ration de contrainte, de deformation recuperable et des essais mecaniques. Pour un cycle unique, l'utilisation d'un taux d'ecrouissage e=1.5 obtenu avec l'application d'une force de tension FT = 0.1sigma y et d'une huile minerale resulte en un echantillon droit, sans microfissure et qui apres un recuit a 400°C, produit un materiau nanostructure manifestant des proprietes fonctionnelles deux fois plus grandes que le meme materiau ayant une structure polygonisee. Pour des cycles repetes, les memes conditions de laminage sont valables mais le niveau de deformation optimal est situe entre e=0.75-2, et depend particulierement du mode de sollicitation, du niveau de stabilisation et du nombre de cycles a la rupture requis par l'application.

  2. Integration des sciences et de la langue: Creation et experimentation d'un modele pedagogique pour ameliorer l'apprentissage des sciences en milieu francophone minoritaire

    NASA Astrophysics Data System (ADS)

    Cormier, Marianne

    Les faibles resultats en sciences des eleves du milieu francophone minoritaire, lors d'epreuves au plan national et international, ont interpelle la recherche de solutions. Cette these avait pour but de creer et d'experimenter un modele pedagogique pour l'enseignement des sciences en milieu linguistique minoritaire. En raison de la presence de divers degres de francite chez la clientele scolaire de ce milieu, plusieurs elements langagiers (l'ecriture, la discussion et la lecture) ont ete integres a l'apprentissage scientifique. Nous avions recommande de commencer le processus d'apprentissage avec des elements langagiers plutot informels (redaction dans un journal, discussions en dyades...) pour progresser vers des activites langagieres plus formelles (redaction de rapports ou d'explications scientifiques). En ce qui a trait a l'apprentissage scientifique, le modele preconisait une demarche d'evolution conceptuelle d'inspiration socio-constructiviste tout en s'appuyant fortement sur l'apprentissage experientiel. Lors de l'experimentation du modele, nous voulions savoir si celui-ci provoquait une evolution conceptuelle chez les eleves, et si, simultanement, le vocabulaire scientifique de ces derniers s'enrichissait. Par ailleurs, nous cherchions a comprendre comment les eleves vivaient leurs apprentissages dans le cadre de ce modele pedagogique. Une classe de cinquieme annee de l'ecole de Grande-Digue, dans le Sud-est du Nouveau-Brunswick, a participe a la mise a l'essai du modele en etudiant les marais sales locaux. Lors d'entrevues initiales, nous avons remarque que les connaissances des eleves au sujet des marais sales etaient limitees. En effet, s'ils etaient conscients que les marais etaient des lieux naturels, ils ne pouvaient pas necessairement les decrire avec precision. Nous avons egalement constate que les eleves utilisaient surtout des mots communs (plantes, oiseaux, insectes) pour decrire le marais. Les resultats obtenus indiquent que les eleves ont

  3. Etude de la performance des radars hautes-frequences CODAR et WERA pour la mesure des courants marins en presence partielle de glace de mer

    NASA Astrophysics Data System (ADS)

    Kamli, Emna

    Les radars hautes-frequences (RHF) mesurent les courants marins de surface avec une portee pouvant atteindre 200 kilometres et une resolution de l'ordre du kilometre. Cette etude a pour but de caracteriser la performance des RHF, en terme de couverture spatiale, pour la mesure des courants de surface en presence partielle de glace de mer. Pour ce faire, les mesures des courants de deux radars de type CODAR sur la rive sud de l'estuaire maritime du Saint-Laurent, et d'un radar de type WERA sur la rive nord, prises pendant l'hiver 2013, ont ete utilisees. Dans un premier temps, l'aire moyenne journaliere de la zone ou les courants sont mesures par chaque radar a ete comparee a l'energie des vagues de Bragg calculee a partir des donnees brutes d'acceleration fournies par une bouee mouillee dans la zone couverte par les radars. La couverture des CODARs est dependante de la densite d'energie de Bragg, alors que la couverture du WERA y est pratiquement insensible. Un modele de fetch appele GENER a ete force par la vitesse du vent predite par le modele GEM d'Environnement Canada pour estimer la hauteur significative ainsi que la periode modale des vagues. A partir de ces parametres, la densite d'energie des vagues de Bragg a ete evaluee pendant l'hiver a l'aide du spectre theorique de Bretschneider. Ces resultats permettent d'etablir la couverture normale de chaque radar en absence de glace de mer. La concentration de glace de mer, predite par le systeme canadien operationnel de prevision glace-ocean, a ete moyennee sur les differents fetchs du vent selon la direction moyenne journaliere des vagues predites par GENER. Dans un deuxieme temps, la relation entre le ratio des couvertures journalieres obtenues pendant l'hiver 2013 et des couvertures normales de chaque radar d'une part, et la concentration moyenne journaliere de glace de mer d'autre part, a ete etablie. Le ratio des couvertures decroit avec l'augmentation de la concentration de glace de mer pour les deux types

  4. Precise femtosecond laser ablation of dental hard tissue: preliminary investigation on adequate laser parameters

    NASA Astrophysics Data System (ADS)

    Hikov, Todor; Pecheva, Emilia; Montgomery, Paul; Antoni, Frederic; Leong-Hoi, Audrey; Petrov, Todor

    2017-01-01

    This work aims at evaluating the possibility of introducing state-of-the-art commercial femtosecond laser system in restorative dentistry by maintaining well-known benefits of lasers for caries removal, but also in overcoming disadvantages such as thermal damage of irradiated substrate. Femtosecond ablation of dental hard tissue is investigated by changing the irradiation parameters (pulsed laser energy, scanning speed and pulse repetition rate), assessed for enamel and dentin. The femtosecond laser system used in this work may be suitable for cavity preparation in dentin and enamel, due to the expected effective ablation and low temperature increase when using ultra short laser pulses. If adequate laser parameters are selected, this system seems to be promising for promoting a laser-assisted, minimally invasive approach in restorative dentistry.

  5. Lamp pumped Nd:YAG laser. Space-qualifiable Nd:YAG laser for optical communications

    NASA Technical Reports Server (NTRS)

    Ward, K. B.

    1973-01-01

    Results are given of a program concerned with the design, fabrication, and evaluation of alkali pump lamps for eventual use in a space qualified Nd:YAG laser system. The study included evaluation of 2mm through 6mm bore devices. Primary emphasis was placed upon the optimization of the 4mm bore lamp and later on the 6mm bore lamp. As part of this effort, reference was made to the Sylvania work concerned with the theoretical modeling of the Nd:YAG laser. With the knowledge gained, a projection of laser performance was made based upon realistic lamp parameters which should easily be achieved during following developmental efforts. Measurements were made on the lamp performance both in and out of the cavity configuration. One significant observation was that for a constant vapor pressure device, the spectral and fluorescent output did not vary for vacuum or argon environment. Therefore, the laser can be operated in an inert environment (eg. argon) with no degradation in output. Laser output of 3.26 watts at 430 watts input was obtained for an optimized 4mm bore lamp.

  6. Nouvelle approche à la prise en charge des condylomes

    PubMed Central

    Lopaschuk, Catharine C.

    2013-01-01

    Résumé Objectif Faire le résumé des anciens et des nouveaux moyens de traitement des verrues génitales ou condylomes et déterminer comment les utiliser de manière appropriée. Sources des données Une recherche documentaire a été effectuée dans les bases de données suivantes: MEDLINE, PubMed, EMBASE, base de données des synthèses systématiques et registre central des études contrôlées de la Collaboration Cochrane (en anglais), ACP Journal Club et Trip. Les bibliographies des articles extraits ont aussi été examinées. Les études cliniques, les articles de révision qualitative, les rapports consensuels et les guides de pratique clinique ont été retenus. Message principal Les verrues symptomatiques sont présentes chez au moins 1 % des personnes âgées entre 15 et 49 ans et on estime que jusqu’à 50 % des gens sont infectés par le virus du papillome humain à un moment donné de leur vie. L’imiquimod et la podophyllotoxine sont 2 nouveaux traitements pour les verrues génitales externes qui sont moins douloureux et peuvent être appliqués par les patients à la maison. De plus, il a été démontré que le vaccin quadrivalent contre le virus du papillome humain est efficace pour prévenir les condylomes et le cancer du col. Les plus anciennes méthodes thérapeutiques ont aussi leur place dans certaines situations, comme les verrues intravaginales, urétrales, anales ou récalcitrantes ou encore pour les patientes enceintes. Conclusion Les nouveaux traitements des verrues génitales externes peuvent réduire la douleur causée par la thérapie et le nombre de visites au cabinet. Les autres méthodes thérapeutiques demeurent utiles dans certaines situations.

  7. Etude de la Morphologie et de la Cinématique de l'Emission des Raies interdites autour des Etoiles T Tauri

    NASA Astrophysics Data System (ADS)

    Lavalley, Claudia

    2000-06-01

    Le phénomène de perte de masse joue un rôle essentiel dès les premières étapes de la formation stellaire et semble être intimement lié à l'accrétion de matière sur l'étoile, probablement par l'intermédiaire de champs magnétiques permettant de convertir l'énergie cinétique accrétée, en puissance d'éjection. Les étoiles T Tauri classiques, âgées de quelques millions d'années et présentant une faible extinction, offrent un excellent cadre pour étudier les régions internes des vents stellaires. Dans ce travail, je présente les premières études sur la morphologie des jets associés aux étoiles DG Tau, CW Tau et RW Aur à une résolution angulaire de 0.1'' et sur la cinématique à deux dimensions de l'émission des raies de [O I]?6300Å, [N II]?6583Å et [S II] ?6716,6731Å dans le jet de DG Tau. Ces données ont été obtenues avec deux techniques d'observation complètement nouvelles, devenues disponibles entre 1994 et 1998 au télescope CFH, et idéalement adaptées à ce problème: l'imagerie en bande étroite derrière l'optique adaptative (PUEO) qui fournit des données à très haute résolution angulaire (~0.1''), et la spectro-imagerie intégrale de champ (TIGRE/OASIS) qui donne accès à l'information spatiale et spectrale à 2D, à haute résolution angulaire (ici ~0.5''-0.75'') et moyenne résolution spectrale (100-170 km/s). Les trois jets étudiés, résolus pour la première fois à partir de 55 u.a. de l'étoile, présentent une largeur similaire (30-35 u.a.) jusqu'à 100 u.a. et une morphologie dominée par des noeuds d'émission. Les jets des étoiles à faible excès infrarouge CW Tau et RW Aur sont très similaires aux deux autres jets des sources peu enfouies observés jusqu'à présent à la même échelle spatiale. Le jet de DG Tau, plus perturbé que les deux autres, et provenant d'une source avec une enveloppe encore importante, est aussi très similaire au seul autre jet associé à une source encore enfouie r

  8. Evaluation of primary tooth enamel surface morphology and microhardness after Nd:YAG laser irradiation and APF gel treatment--an in vitro study.

    PubMed

    Banda, Naveen Reddy; Vanaja Reddy, G; Shashikiran, N D

    2011-01-01

    Laser irradiation and fluoride has been used as a preventive tool to combat dental caries in permanent teeth, but little has been done for primary teeth which are more prone to caries. The purpose of this study was to evaluate microhardness alterations in the primary tooth enamel after Nd-YAG laser irradiation alone and combined with topical fluoride treatment either before or after Nd-YAG laser irradiation. Ten primary molars were sectioned and assigned randomly to: control group, Nd-YAG laser irradiation, Nd-YAG lasing before APF and APF followed by Nd-YAG lasing. The groups were evaluated for microhardness. Surface morphological changes were observed using SEM. Statistical comparisons were performed. The control group's SEM showed a relatively smooth enamel surface and lasing group had fine cracks and porosities. In the lasing + fluoride group a homogenous confluent surface was seen. In the fluoride + lasing group an irregular contour with marked crack propagation was noted. There was a significant increase in the microhardness of the treatment groups. Nd-YAG laser irradiation and combined APF treatment of the primary tooth enamel gave morphologically hardened enamel surface which can be a protective barrier against a cariogenic attack.

  9. Colour-Difference Measurement Method for Evaluation of Quality of Electrolessly Deposited Copper on Polymer after Laser-Induced Selective Activation

    PubMed Central

    Gedvilas, Mindaugas; Ratautas, Karolis; Kacar, Elif; Stankevičienė, Ina; Jagminienė, Aldona; Norkus, Eugenijus; Li Pira, Nello; Račiukaitis, Gediminas

    2016-01-01

    In this work a novel colour-difference measurement method for the quality evaluation of copper deposited on a polymer is proposed. Laser-induced selective activation (LISA) was performed onto the surface of the polycarbonate/acrylonitrile butadiene styrene (PC/ABS) polymer by using nanosecond laser irradiation. The laser activated PC/ABS polymer was copper plated by using the electroless copper plating (ECP) procedure. The sheet resistance measured by using a four-point probe technique was found to decrease by the power law with the colour-difference of the sample images after LISA and ECP procedures. The percolation theory of the electrical conductivity of the insulator conductor mixture has been adopted in order to explain the experimental results. The new proposed method was used to determine an optimal set of the laser processing parameters for best plating conditions. PMID:26960432

  10. Sonderverfahren des Spritzgießens

    NASA Astrophysics Data System (ADS)

    Michaeli, Walther; Lettowsky, Christoph

    Das Spritzgießen ist neben der Extrusion das wichtigste Verarbeitungsverfahren für Kunststoffe [1]. Das Verfahren hat sich seit seinen Ursprüngen Ende des 19. Jahrhunderts bis heute stetig weiterentwickelt [2]. In neuerer Zeit steigt die Anzahl komplexer Anwendungen, die die gezielte Kombination verschiedener Funktionalitäten in einem Formteil erfordern. Das Standard-Spritzgießen kann diese Anforderungen immer weniger befriedigen. Daher gewinnen die Sonderverfahren des Spritzgießens zunehmend an Bedeutung [3]. Ihre Anzahl beträgt inzwischen über 100. Die Aufgabe des Anwenders ist es, aus der Vielzahl der möglichen Verfahren, ein anforderungsgerechtes auszuwählen, das sowohl unter technischen wie wirtschaftlichen Gesichtspunkten die optimale Lösung darstellt. Dies setzt die ständige Auseinandersetzung mit Entwicklungstendenzen im Bereich der Spritzgießtechnologie voraus. Daher soll im folgenden Abschnitt ein Überblick über die wichtigsten Spritzgieß-Sonderverfahren gegeben werden.

  11. Révision systématique des effets de la fréquence des repas en famille sur les résultats psychosociaux chez les jeunes

    PubMed Central

    Harrison, Megan E.; Norris, Mark L.; Obeid, Nicole; Fu, Maeghan; Weinstangel, Hannah; Sampson, Margaret

    2015-01-01

    Résumé Objectif Effectuer une révision systématique des effets de repas en famille fréquents sur les résultats psychosociaux chez les enfants et les adolescents et examiner s’il existe des différences dans les résultats selon le sexe. Sources des données Des études ont été cernées à la suite d’une recherche dans MEDLINE (de 1948 à la dernière semaine de juin 2011) et dans PsycINFO (de 1806 à la première semaine de juillet 2011) à l’aide de l’interface Ovide. Les expressions et mots clés MeSH utilisés seuls ou en combinaisons étaient les suivants : family, meal, food intake, nutrition, diets, body weight, adolescent attitudes, eating behaviour, feeding behaviour et eating disorders. Les bibliographies des articles jugés pertinents ont aussi été passées en revus. Sélection des études La recherche initiale a produit 1783 articles. Pour être incluses dans l’analyse, les études devaient répondre aux critères suivants : être publiées en anglais dans une revue révisée par des pairs; porter sur des enfants ou des adolescents; traiter de l’influence des repas en famille sur les paramètres psychosociaux (p. ex. consommation de drogues et autres substances, troubles de l’alimentation, dépression) chez les enfants ou les adolescents; avoir une conception d’étude appropriée, notamment des méthodes statistiques acceptables pour l’analyse des paramètres. Quatorze articles satisfaisaient aux critères d’inclusion. Deux examinateurs indépendants ont étudié et analysé les articles. Synthèse Dans l’ensemble, les résultats font valoir que la fréquence des repas en famille est inversement proportionnelle aux troubles de l’alimentation, à la consommation d’alcool et de drogues, aux comportements violents, aux sentiments de dépression ou aux pensées suicidaires chez les adolescents. Il existe une relation positive entre de fréquents repas en famille, une bonne estime de soi et la réussite scolaire. Les

  12. Evaluation of thermal cooling mechanisms for laser application to teeth.

    PubMed

    Miserendino, L J; Abt, E; Wigdor, H; Miserendino, C A

    1993-01-01

    Experimental cooling methods for the prevention of thermal damage to dental pulp during laser application to teeth were compared to conventional treatment in vitro. Pulp temperature measurements were made via electrical thermistors implanted within the pulp chambers of extracted human third molar teeth. Experimental treatments consisted of lasing without cooling, lasing with cooling, laser pulsing, and high-speed dental rotary drilling. Comparisons of pulp temperature elevation measurements for each group demonstrated that cooling by an air and water spray during lasing significantly reduced heat transfer to dental pulp. Laser exposures followed by an air and water spray resulted in pulp temperature changes comparable to conventional treatment by drilling. Cooling by an air water spray with evacuation appears to be an effective method for the prevention of thermal damage to vital teeth following laser exposure.

  13. Résultats fonctionnels des lésions des tendons fléchisseurs de la main: à propos de 90 cas

    PubMed Central

    Boussakri, Hassan; Azarkane, Mohamad; Elidrissi, Mohamad; Shimi, Mohamad; Elibrahimi, Abdelhalim; Elmrini, Abdelmajid

    2013-01-01

    Les auteurs rapportent une série de 90 patients, présentant une section tendineuse des fléchisseurs de la main, et suivis avec un recul moyen de 8 mois (min: 2 mois; max: 13 mois). La lésion était localisée dans 12% des cas en zone I, 46% des cas en zone II, 2% en zone III et 25% des cas en zone IV et V. Pour le pouce (13 patients), 10 cas en zone T2 et 3 cas en zone T3. La technique opératoire utilisée était les sutures tendineuses en cadre de Kessler modifié, associée à un surjet épitendineux. Nous avons obtenus 54% de très bons résultats, 34% de résultats moyens et 12% de mauvais résultats. Pour le pouce les résultats semble moins bons avec un taux de résultats médiocre de 48%. Certes les chiffres de cette série sont moins bons que ceux des autres séries publiées dans la littérature. Les facteurs influençant les résultats sont d'abord l'utilisation d'immobilisation postopératoire systématique ainsi que le mécanisme d'agression, et la localisation à la zone II et au pouce. Les complications mécaniques sont représentées par 7% de rupture, toutes au niveau de pouce, et 31% des adhérences tendineuses (soit 30 cas), dont 19 en zone II, l'infections (22%) et 4% des cas d'algodystrophies. PMID:23847698

  14. Mid-Infrared Laser Orbital Septal Tightening

    PubMed Central

    Chu, Eugene A.; Li, Michael; Lazarow, Frances B.; Wong, Brian J. F.

    2014-01-01

    IMPORTANCE Blepharoplasty is one of the most commonly performed facial aesthetic surgeries. While myriad techniques exist to improve the appearance of the lower eyelids, there is no clear consensus on the optimal management of the orbital septum. OBJECTIVES To evaluate the safety and feasibility of the use of the holmium:yttrium aluminum garnet (Ho:YAG) laser for orbital septal tightening, and to determine whether modest use of this laser would provide some degree of clinical efficacy. DESIGN, SETTING, AND PARTICIPANTS Direct laser irradiation of ex vivo bovine tissue was used to determine appropriate laser dosimetry using infrared thermal imaging and optical coherence tomography before conducting a pilot clinical study in 5 patients. Laser irradiation of the lower eyelid orbital septum was performed through a transconjunctival approach. Standardized preoperative and postoperative photographs were taken for each patient and evaluated by 6 unbiased aesthetic surgeons. EXPOSURE Use of the Ho:YAG laser for orbital septal tightening. MAIN OUTCOME AND MEASURE To determine appropriate laser dosimetry, infrared thermal imaging and optical coherence tomography were used to monitor temperature and tissue shape changes of ex vivo bovine tissue that was subjected to direct laser irradiation. For the clinical study, preoperative and postoperative photographs were evaluated by 6 surgeons on a 10-point Likert scale. RESULTS Optical coherence tomography demonstrated that laser irradiation of bovine tissue to a temperature range of 60°C to 80°C resulted in an increase in thickness of up to 2-fold. There were no complications or adverse cosmetic outcomes in the patient study. Patient satisfaction with the results of surgery averaged 7 on a 10-point Likert scale. For 3 patients, 3 (50%) of the evaluators believed there was a mild improvement in appearance of the lower eyelids after surgery. The remaining patients were thought to have no significant changes. CONCLUSIONS AND

  15. Receiver Design, Performance Analysis, and Evaluation for Space-Borne Laser Altimeters and Space-to-Space Laser Ranging Systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1996-01-01

    This progress report consists of two separate reports. The first one describes our work on the use of variable gain amplifiers to increase the receiver dynamic range of space borne laser altimeters such as NASA's Geoscience Laser Altimeter Systems (GLAS). The requirement of the receiver dynamic range was first calculated. A breadboard variable gain amplifier circuit was made and the performance was fully characterized. The circuit will also be tested in flight on board the Shuttle Laser Altimeter (SLA-02) next year. The second report describes our research on the master clock oscillator frequency calibration for space borne laser altimeter systems using global positioning system (GPS) receivers.

  16. Developpements numeriques recents realises en aeroelasticite chez Dassault Aviation pour la conception des avions de combat modernes et des avions d’affaires

    DTIC Science & Technology

    2003-03-01

    combat modernes et des avions d’affaires E. Garrigues, Th. Percheron DASSAULT AVIATION DGT/DTA/IAP F-922 14, Saint-Cloud Cedex France 1. Introduction ...de vol, des acedidrations rigides et des rdponses de la structure ( jauges et acedidrations). Struturl Premdicton Grdjustments n~~~ligh Testsn~n Fig4ure

  17. Carbon dioxide laser versus erbium:YAG laser in treatment of epidermal verrucous nevus: a comparative randomized clinical study.

    PubMed

    Osman, Mai Abdel Raouf; Kassab, Ahmed Nazmi

    2017-08-01

    A verrucous epidermal nevus (VEN) is a skin disorder that has been treated using different treatment modalities with varying results. Ablative lasers such as carbon dioxide laser (CO 2 ) and erbium:yttrium-aluminum-garnet (Er:YAG) laser have been considered as the gold standard for the treatment of epidermal nevi. To evaluate and compare the efficacy, postoperative wound healing and side effects of pulsed CO 2 laser and Er:YAG laser for the treatment of verrucous epidermal nevi. Twenty patients with localized VEN were randomly divided into two groups. Group 1 was administered CO 2 laser and group 2 underwent Er:YAG laser treatment. A blinded physician evaluated the photographs and dermoscopic photomicrographs for the efficacy and possible side effects. All patients received one treatment session and were followed up over a 6-month period. Both lasers induced noticeable clinical improvement, but there were no significant differences between two lasers in treatment response, patient satisfaction, duration of erythema and side effects. The average time to re-epithelialization was 13.5 days with CO 2 and 7.9 days with Er:YAG laser (p< .0005). No scarring was observed in Er:YAG laser group and no lesional recurrence was detected in CO 2 laser group since treatment. Apart from re-epithelialization, both lasers showed equivalent outcomes with respect to treatment response, patient satisfaction, side effects and complications.

  18. Discovery of the Lensed Quasar System DES J0408-5354

    DOE PAGES

    Lin, H.; Buckley-Geer, E.; Agnello, A.; ...

    2017-03-27

    We report the discovery and spectroscopic confirmation of the quad-like lensed quasar system DES J0408-5354 found in the Dark Energy Survey (DES) Year 1 (Y1) data. This system was discovered during a search for DES Y1 strong lensing systems using a method that identified candidates as red galaxies with multiple blue neighbors. DES J0408-5354 consists of a central red galaxy surrounded by three bright (more » $$i\\lt 20$$) blue objects and a fourth red object. Subsequent spectroscopic observations using the Gemini South telescope confirmed that the three blue objects are indeed the lensed images of a quasar with redshift z = 2.375, and that the central red object is an early-type lensing galaxy with redshift z = 0.597. DES J0408-5354 is the first quad lensed quasar system to be found in DES and begins to demonstrate the potential of DES to discover and dramatically increase the sample size of these very rare objects.« less

  19. Discovery of the Lensed Quasar System DES J0408-5354

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, H.; Buckley-Geer, E.; Agnello, A.

    We report the discovery and spectroscopic confirmation of the quad-like lensed quasar system DES J0408-5354 found in the Dark Energy Survey (DES) Year 1 (Y1) data. This system was discovered during a search for DES Y1 strong lensing systems using a method that identified candidates as red galaxies with multiple blue neighbors. DES J0408-5354 consists of a central red galaxy surrounded by three bright (more » $$i\\lt 20$$) blue objects and a fourth red object. Subsequent spectroscopic observations using the Gemini South telescope confirmed that the three blue objects are indeed the lensed images of a quasar with redshift z = 2.375, and that the central red object is an early-type lensing galaxy with redshift z = 0.597. DES J0408-5354 is the first quad lensed quasar system to be found in DES and begins to demonstrate the potential of DES to discover and dramatically increase the sample size of these very rare objects.« less

  20. High power diode lasers for solid-state laser pumps

    NASA Technical Reports Server (NTRS)

    Linden, Kurt J.; Mcdonnell, Patrick N.

    1994-01-01

    The development and commercial application of high power diode laser arrays for use as solid-state laser pumps is described. Such solid-state laser pumps are significantly more efficient and reliable than conventional flash-lamps. This paper describes the design and fabrication of diode lasers emitting in the 780 - 900 nm spectral region, and discusses their performance and reliability. Typical measured performance parameters include electrical-to-optical power conversion efficiencies of 50 percent, narrow-band spectral emission of 2 to 3 nm FWHM, pulsed output power levels of 50 watts/bar with reliability values of over 2 billion shots to date (tests to be terminated after 10 billion shots), and reliable operation to pulse lengths of 1 ms. Pulse lengths up to 5 ms have been demonstrated at derated power levels, and CW performance at various power levels has been evaluated in a 'bar-in-groove' laser package. These high-power 1-cm stacked-bar arrays are now being manufactured for OEM use. Individual diode laser bars, ready for package-mounting by OEM customers, are being sold as commodity items. Commercial and medical applications of these laser arrays include solid-state laser pumping for metal-working, cutting, industrial measurement and control, ranging, wind-shear/atmospheric turbulence detection, X-ray generation, materials surface cleaning, microsurgery, ophthalmology, dermatology, and dental procedures.

  1. Highly efficient evaluation of a gas mixer using a hollow waveguide based laser spectral sensor.

    PubMed

    Du, Z; Yang, X; Li, J; Yang, Y; Qiao, C

    2017-05-01

    This paper aims to provide a fast, sensitive, and accurate characterization of a Mass Flow Controller (MFC) based gas mixer. The gas mixer was evaluated by using a hollow waveguide based laser spectral sensor with high efficiency. Benefiting from the sensor's fast response, high sensitivity and continuous operation, multiple key parameters of the mixer, including mixing uncertainty, linearity, and response time, were acquired by a one-round test. The test results show that the mixer can blend multi-compound gases quite efficiently with an uncertainty of 1.44% occurring at a flow rate of 500 ml/min, with the linearity of 0.998 43 and the response time of 92.6 s. The results' reliability was confirmed by the relative measurement of gas concentration, in which the isolation of the sensor's uncertainty was conducted. The measured uncertainty has shown well coincidence with the theoretical uncertainties of the mixer, which proves the method to be a reliable characterization. Consequently, this sort of laser based characterization's wide appliance on gas analyzer's evaluations is demonstrated.

  2. Highly efficient evaluation of a gas mixer using a hollow waveguide based laser spectral sensor

    NASA Astrophysics Data System (ADS)

    Du, Z.; Yang, X.; Li, J.; Yang, Y.; Qiao, C.

    2017-05-01

    This paper aims to provide a fast, sensitive, and accurate characterization of a Mass Flow Controller (MFC) based gas mixer. The gas mixer was evaluated by using a hollow waveguide based laser spectral sensor with high efficiency. Benefiting from the sensor's fast response, high sensitivity and continuous operation, multiple key parameters of the mixer, including mixing uncertainty, linearity, and response time, were acquired by a one-round test. The test results show that the mixer can blend multi-compound gases quite efficiently with an uncertainty of 1.44% occurring at a flow rate of 500 ml/min, with the linearity of 0.998 43 and the response time of 92.6 s. The results' reliability was confirmed by the relative measurement of gas concentration, in which the isolation of the sensor's uncertainty was conducted. The measured uncertainty has shown well coincidence with the theoretical uncertainties of the mixer, which proves the method to be a reliable characterization. Consequently, this sort of laser based characterization's wide appliance on gas analyzer's evaluations is demonstrated.

  3. An evaluation of SAO sites for laser operations

    NASA Technical Reports Server (NTRS)

    Thorp, J. M.; Bush, M. A.; Pearlman, M. R.

    1974-01-01

    Operational criteria are provided for the selection of laser tracking sites for the Earth and Ocean Physics Applications Program. A compilation of data is given concerning the effect of weather conditions on laser and Baker-Nunn camera operations. These data have been gathered from the Smithsonian astrophysical observing station sites occupied since the inception of the satellite tracking program. Also given is a brief description of each site, including its characteristic weather conditions, comments on communications and logistics, and a summary of the terms of agreement under which the station is or was operated.

  4. Comparison of solar and laser macula retinal injury using scanning laser ophthalmoscopy spectral imaging

    NASA Astrophysics Data System (ADS)

    Zwick, Harry; Gagliano, Donald A.; Stuck, Bruce E.; Lund, David J.

    1994-07-01

    Both solar and laser sources may induce punctate foveal retinal damage. Unprotected viewing of the sun or bright blue sky represent potential solar radiation causes of photic maculopathy that may induce punctate foveal damage. Laser induced macular retinal damage is another more recent kind of photic maculopathy. Most documented cases of laser photic maculopathy have involved acute laser exposure generally from Q-switched visible or nonvisible near IR laser systems. In our comparison of these types of photic maculopathies, we have employed conventional as well as spectral and confocal scanning laser ophthalomoscopy to evaluate the depth of the photic maculopathy. Functionally, we have observed a tritan color vision loss present in nearly all photic maculopathies.

  5. SEM Evaluation of Enamel Surface Changes and Enamel Microhardness around Orthodontic Brackets after Application of CO2 Laser, Er,Cr:YSGG Laser and Fluoride Varnish: An In vivo Study.

    PubMed

    Kaur, Tarundeep; Tripathi, Tulika; Rai, Priyank; Kanase, Anup

    2017-09-01

    One of the most undesirable consequences of orthodontic treatment is occurrence of enamel demineralization around orthodontic brackets. Numerous in vitro studies have reported the prevention of enamel demineralization by surface treatment with lasers and fluoride varnish. To evaluate the changes on the enamel surface and microhardness around orthodontic brackets after surface treatment by CO 2 laser, Er, Cr:YSGG laser and fluoride varnish in vivo. A double blind interventional study was carried out on 100 premolars which were equally divided into five groups, out of which one was the control group (Group 0). The intervention groups (Group I to IV) comprised of patients requiring fixed orthodontic treatment with all 4 first premolars extraction. Brackets were bonded on all 80 premolars which were to be extracted. Enamel surface treatment of Groups I, II and III was done by CO 2 laser, Er, Cr:YSGG laser and 5% sodium fluoride varnish respectively and Group IV did not receive any surface treatment. A modified T-loop was ligated to the bracket and after two months, the premolars were extracted. Surface changes were evaluated by Scanning Electron Microscopic (SEM) and microhardness testing. Comparison of mean microhardness between all the groups was assessed using post-hoc test with Bonferroni correction. Group I showed a melted enamel appearance with fine cracks and fissures while Group II showed a glossy, homogenous enamel surface with well coalesced enamel rods. Group III showed slight areas of erosions and Group IV presented areas of stripped enamel. Significant difference was observed between the mean microhardness (VHN) of Group I, Group II, Group III, Group IV and Group 0 with p<0.001. A significant difference of p<0.001 was observed while comparing Group I vs II,III,IV,0 and Group II vs III,IV,0. However, difference while comparing Group III vs IV was p=0.005 and difference between the mean microhardness of Group 0 vs Group III was non significant. Surface

  6. A 35-month profilometric and clinical evaluation of non-ablative remodeling using a 1540-nm Er:glass laser.

    PubMed

    Fournier, Nathalie; Lagarde, Jean Michel; Turlier, Virginie; Courrech, Laetitia; Mordon, Serge

    2004-11-01

    As remodeling is getting more popular with patients, long-term studies are becoming necessary. The aim of this 35-month clinical study was to evaluate the long-term benefits obtained using a 1540-nm Er:glass laser for non-ablative remodeling of perioral and periorbital rhytids. The role of maintenance treatments was also investigated. Eleven women with periorbital and perioral rhytids underwent a series of five treatments at 6-week intervals with an Er:glass laser. Five patients subsequently received two maintenance retreatments and six did not. The maintenance treatments were performed at 14 and 20 months. Silicone imprints were performed to measure anisotropy before treatment, at 6 months, at 14 months and at 35 months. Patient self-evaluation/questionnaire was also done to assess adverse effects and subjective clinical improvement. For all 11 patients, the percentage of anisotropy reduction was 41.21% at 6 months, 51.76% at 14 months and 29.87% at 35 months. No adverse effects were noted. Patient satisfaction was high at the end of the evaluation. Retreated patients were more satisfied than non-retreated ones. However, there was no difference in the anisotropy factor between the two groups. Treatment of facial rhytids with a non-ablative 1540-nm Er:glass laser system can produce benefits that persist over 2 years after the last treatment.

  7. Effects of copper vapor laser (CVL) on mice skin: histologic evaluation of damage and tissue stimulation

    NASA Astrophysics Data System (ADS)

    Nunes, Syllene; Moreno, E.; Oliveira, H.; Osaka, J.; Salvador, G.; Michalany, N.; Tolosa, E.

    2002-10-01

    This study was to evaluate the effects of the CVL with low energy and short pulse widths. 18 female mice, C57BL/6 (9-11 weeks old) were distributed into four groups. The control group (CG) wasn't exposed to laser beam . Group L1 had 2 laser expositions with 24 hours gap between them (0.5W). Group L2 had 3 expositions (0.5W and 0.25W) and group L3 had 4 expositions (0.25 W). It was used a CVL prototype (5lOnm, 13 Khz, pulse width of 20 ms and spot size of 0.8cm). 7 days after last laser pulse no groups presented actinic keratosis, tumors or collagen changes. CVL had effective action on pilosebaceous units. High energy with few short pulses induced hair follicles proliferation while low energy with many repetitive short pulses showed increased and specific tissue damage besides hair plugging.

  8. Analyse des possibilités de fonctionnement en régime des désexcitation des moteurs à aimants permanents

    NASA Astrophysics Data System (ADS)

    Multon, Bernard; Lucidarme, Jean; Prévond, Laurent

    1995-05-01

    In this paper, we study the extending of speed range of motors (or generators) with permanent magnet inductor and supplied by electronic converter. The amplitude of phase voltage and current waveforms are limited by electronics supply. The aim of this study is to achieve a maximum power near of the base speed one on an extended speed range. This require an airgap flux weakening so called “flux weakening” above base speed. A parametric analysis of motor electromagnetic characteristics is made to show the influence of armature reaction and magnetic saliency on speed range. We show that exists an ideal condition to obtain a constant power speed range theoretically unlimited. Magnetic saliency permits to enhance the power factor especially when L_d> L_q. As main hypotheses, we consider no saturation, e.m.f. and current sine waveforms and a sinusoidal airgap flux density. Finally, we recapitulate the permanent magnet rotor structures able to obtain a flux-weakening operation. Cet article traite de l'extension de la plage de vitesse des moteurs (ou alternateurs) à excitation par aimants permanents et alimentés par convertisseur électronique. La tension et le courant sont limités en amplitude par l'alimentation électronique.L'objectif est d'obtenir une puissance proche de celle correspondant au régime de base sur une plage de vitesse étendue. Ceci nécessite une réduction de flux d'entrefer ou “désexition” au delà de la vitesse de base. Une analyse paramétrique des caractéristiques du moteur est effectuée pour mettre en évidence l'influence de la réaction d'induit et de la saillance magnétique. Nous montrons qu'il existe une condition idéale pour obtenir une plage de fonctionnement à puissance constante théoriquement illimitée. La saillance magnétique permet d'accroître le facteur de puissance surtout lorsque L_d> L_q. Les principales hypothèses de cette étude sont l'absence de saturation, des f.e.m. et des courants sinusoïdaux et une

  9. Criteria for the evaluation of laser solar energy converter systems

    NASA Technical Reports Server (NTRS)

    Harries, W. L.

    1985-01-01

    Assuming that a parabolic insolation-collection mirror-based solar pumped laser has a collector and heat emitter whose weights are proportional to their areas, and that the weight of the laser is negligible by comparison, the output power/unit weight can be expressed in terms of the efficiencies and working temperatures of the system. This ratio appears to be several times higher for an IBr laser than for one operating on C3F7I, because the solar utilization efficiency is greater for the former despite its lower working temperature.

  10. Formation des etoiles massives dans les galaxies spirales

    NASA Astrophysics Data System (ADS)

    Lelievre, Mario

    Le but de cette thèse est de décrire la formation des étoiles massives dans les galaxies spirales appartenant à divers types morphologiques. L'imagerie Hα profonde combinée à une robuste méthode d'identification des régions HII ont permis de détecter et de mesurer les propriétés (position, taille, luminosité, taux de formation d'étoiles) de plusieurs régions HII situées dans le disque interne (R < R25) de dix galaxies mais aussi à leur périphérie (R ≥ R 25). De façon générale, la répartition des régions HII ne montre aucune évidence de structure morphologique à R < R25 (bras spiraux, anneau, barre) à moins de limiter l'analyse aux régions HII les plus grosses ou les plus lumineuses. La répartition des régions HII, de même que leur taille et leur luminosité, sont toutefois sujettes à de forts effets de sélection qui dépendent de la distance des galaxies et qu'il faut corriger en ramenant l'échantillon à une résolution spatiale commune. Les fonctions de luminosité montrent que les régions HII les plus brillantes ont tendance à se former dans la portion interne du disque. De plus, l'analyse des pentes révèle une forte corrélation linéaire par rapport au type morphologique. Aucun pic n'est observé dans les fonctions de luminosité à log L-37 qui révèlerait la transition entre les régions HII bornées par l'ionisation et par la densité. Une relation cubique est obtenue entre la taille et la luminosité des régions HII, cette relation variant toutefois de façon significative entre le disque interne et la périphérie d'une même galaxie. La densité et la dynamique du gaz et des étoiles pourraient influencer de façon significative la stabilité des nuages moléculaires face à l'effondrement gravitationnel. D'une part, l'étendue du disque de régions HII pour cinq galaxies de l'échantillon coïncide avec celle de l'hydrogène atomique. D'autre part, en analysant la stabilité des disques galactiques, on conclue

  11. Development of lasers optimized for pumping Ti:Al2O3 lasers

    NASA Technical Reports Server (NTRS)

    Rines, Glen A.; Schwarz, Richard A.

    1994-01-01

    Laboratory demonstrations that were completed included: (1) an all-solid-state, broadly tunable, single-frequency, Ti:Al2O3 master oscillator, and (2) a technique for obtaining 'long' (nominally 100- to 200-ns FWHM) laser pulses from a Q-switched, Nd oscillator at energy levels commensurate with straightforward amplification to the joule level. A diode-laser-pumped, Nd:YLF laser with intracavity SHG was designed, constructed, and evaluated. With this laser greater than 0.9 W of CW, output power at 523.5 nm with 10 W of diode-laser pump power delivered to the Nd:YLF crystal was obtained. With this laser as a pump source, for the first time, to our knowledge, an all solid-state, single frequency, Ti:Al203 laser with sufficient output power to injection seed a high-energy oscillator over a 20-nm bandwidth was demonstrated. The pulsed laser work succeeded in demonstrating pulse-stretching in a Q-switched Nd:YAG oscillator. Pulse energies greater than 50-mJ were obtained in pulses with 100- to 200-ns pulsewidths (FWHM).

  12. Laser safety in dentistry

    NASA Astrophysics Data System (ADS)

    Wigdor, Harvey A.

    1997-05-01

    One of the major causes of anxiety in the dental clinic is the dental handpiece. Because dentists wish to provide a method which can replace the drill there has often been a premature use of the laser in dentistry. Various lasers have been introduced into the clinic before research has shown the laser used is of clinical benefit. Any new treatment method must not compromise the health of the patient being treated. Thus a method of evaluating the clinical abilities of dentists and their understanding the limitations of the laser used must be developed. Dentist must be trained in the basic interaction of the laser on oral tissues. The training has to concentrate on the variation of the laser wavelength absorption in the different tissues of the oral cavity. Because of the differences in the optical properties of these tissues great care must be exercised by practitioners using lasers on patients.

  13. On a Fundamental Evaluation of a Uav Equipped with a Multichannel Laser Scanner

    NASA Astrophysics Data System (ADS)

    Nakano, K.; Suzuki, H.; Omori, K.; Hayakawa, K.; Kurodai, M.

    2018-05-01

    Unmanned aerial vehicles (UAVs), which have been widely used in various fields such as archaeology, agriculture, mining, and construction, can acquire high-resolution images at the millimetre scale. It is possible to obtain realistic 3D models using high-overlap images and 3D reconstruction software based on computer vision technologies such as Structure from Motion and Multi-view Stereo. However, it remains difficult to obtain key points from surfaces with limited texture such as new asphalt or concrete, or from areas like forests that may be concealed by vegetation. A promising method for conducting aerial surveys is through the use of UAVs equipped with laser scanners. We conducted a fundamental performance evaluation of the Velodyne VLP-16 multi-channel laser scanner equipped to a DJI Matrice 600 Pro UAV at a construction site. Here, we present our findings with respect to both the geometric and radiometric aspects of the acquired data.

  14. Evaluation of Intraocular Inflammation with Laser Flare Photometry in Behçet Uveitis.

    PubMed

    Yalcindag, Fatime Nilufer; Bingol Kiziltunc, Pinar; Savku, Esra

    2017-02-01

    To evaluate the association between intraocular inflammation and laser flare photometry measurements in Behçet disease. In total, 45 patients were included in the study. The retrospective chart reviews of patients were performed. The flare levels were compared with the grade of anterior chamber cells, the presence of vitreous cells, the complications of uveitis, and fluorescein angiography scores. The attack group had higher flare intensity; the flare levels were higher in both groups compared with the values of healthy controls. The flare levels were related to the grade of the anterior chamber cells, the presence of vitreous cells and the fluorescein angiography scores. Patients with optic atrophy and/or maculopathy also had higher values. Higher flare values were correlated with poor vision. Laser flare photometry may reduce the necessity of fluorescein angiography in monitoring subclinical inflammation and may be an indicator of posterior segment activity when fluorescein angiography is not applicable.

  15. A simple approach to industrial laser safety.

    PubMed

    Lewandowski, Michael A; Hinz, Michael W

    2005-02-01

    Industrial applications of lasers include marking, welding, cutting, and other material processing. Lasers used in these ways have significant power output but are generally designed to limit operator exposure to direct or scattered laser radiation to harmless levels in order to meet the Federal Laser Product Performance Standard (21CFR1040) for Class 1 laser products. Interesting challenges occur when companies integrate high power lasers into manufacturing or process control equipment. A significant part of the integration process is developing engineering and administrative controls to produce an acceptable level of laser safety while balancing production, maintenance, and service requirements. 3M Company uses a large number of high power lasers in numerous manufacturing processes. Whether the laser is purchased as a Class 1 laser product or whether it is purchased as a Class 4 laser and then integrated into a manufacturing application, 3M Company has developed an industrial laser safety program that maintains a high degree of laser safety while facilitating the rapid and economical integration of laser technology into the manufacturing workplace. This laser safety program is based on the requirements and recommendations contained in the American National Standard for Safe Use of Lasers, ANSI Z136.1. The fundamental components of the 3M program include hazard evaluation, engineering, administrative, and procedural controls, protective equipment, signs and labels, training, and re-evaluation upon change. This program is implemented in manufacturing facilities and has resulted in an excellent history of laser safety and an effective and efficient use of laser safety resources.

  16. Cancer du sein au Maroc: profil phénotypique des tumeurs

    PubMed Central

    Khalil, Ahmadaye Ibrahim; Bendahhou, Karima; Mestaghanmi, Houriya; Saile, Rachid; Benider, Abdellatif

    2016-01-01

    Le cancer du sein est le plus fréquent chez la femme et figure parmi les principales causes de mortalité liées au cancer. La curabilité de ce type tumoral est en augmentation, grâce aux programmes de dépistage et aux progrès thérapeutiques, qui ont certes augmenté la survie des patients. Mais des défis restent à relever en rapport avec l’instabilité phénotypique des cellules cancéreuses. L’objectif de ce travail est d’étudier le profil phénotypique du cancer du sein chez les patients pris en charge au Centre Mohammed VI pour le traitement des Cancers, durant les années 2013-2014. Il s’agit d’une étude transversale sur deux années, incluant les cas du cancer du sein pris en charge au Centre. Le recueil des données était fait à partir des dossiers des patients et analysés par le logiciel Epi Info. 1277 patients ont été pris en charge au sein de notre centre. 99,5% des cas de sexe féminin, l’âge moyen était 50,20 ± 11,34 ans. Le type histologique le plus fréquent était le carcinome canalaire infiltrant (80,7% des cas). Le stade diagnostic était précoce (56,9%). Le phénotype moléculaire le plus fréquent était le luminal A (41,4% des cas). Le luminal B, le HER2 et les triples négatifs étaient dans respectivement 10,4%, 6,3%, 11,2% des cas. L’étude du phénotype tumoral des patients atteints du cancer du sein permet l’orientation du clinicien dans le choix du traitement, et des décideurs dans la planification de programmes de lutte contre cette pathologie. PMID:28292037

  17. Hair ignition by dye laser for port-wine stain: risk factors evaluated.

    PubMed

    Molin, L; Hallgren, S

    1999-04-01

    Flashlamp-pumped pulsed dye laser is the preferred treatment for port-wine stain. Vascular hemoglobin and epidermal melanin are competing sites for dye laser absorption and damage. The case presented illustrates the potential hazard of ignition induced by dye laser treatment on the face of a patient receiving inhalation anesthesia. A 6-year-old girl with almost black hair was treated for a port-wine stain covering most of the right half of her face. She was treated with dye laser under general anesthesia administered by mask. A laser pulse close to the upper part of the eyebrow induced a blaze and the eyebrow was instantly destroyed by the fire. Regrowth of the eyebrow was complete after a few months. Hair specimens of various colors were exposed experimentally to dye laser irradiation in room and oxygen-saturated atmospheres. Risk factors of ignition are high laser dosage, a high oxygen level, repeated pulses and dark colored hair.

  18. Orange fiber laser for ophthalmology

    NASA Astrophysics Data System (ADS)

    Adachi, M.; Kojima, K.; Hayashi, K.

    2007-02-01

    For the light source of photocoagulators for ophthalmology, orange laser is more suitable than green laser because of low scattering loss by the crystalline lens, and low absorption by xanthophylls in the retina. We developed two orange fiber lasers (580 nm and 590 nm) to investigate the effect depending on the difference in the range of orange. The 580nm laser is composed of a 1160 nm fiber laser and a Periodically Polled Lithium Niobate (PPLN) crystal for second harmonic generation. The 1160 nm fiber laser beam is focused into the MgO-doped PPLN crystal whose length is 30 mm with 3-pass configuration. Continuous-wave 1.3 W output power of 580 nm was obtained with 5.8 W input power of 1160nm for the first time. The conversion efficiency was 22%. The band width of the second harmonic was 0.006 nm (FWHM). The 590 nm laser is almost the same as 580 nm laser source. In this case we used a Raman shift fiber to generate 1180 nm, and the output power of 590 nm was 1.4 W. We developed an evaluation model of photocoagulator system using these two laser sources. A 700 mW coagulation output power was obtained with this orange fiber laser photocoagulator system. This is enough power for the eye surgery. We have the prospect of the maintenance-free, long-life system that is completely air-cooled. We are planning to evaluate this photocoagulator system in order to investigate the difference between the two wavelengths at the field test.

  19. High-Lift System Aerodynamics (L’Aerodynamique des Systems Hypersustentateurs)

    DTIC Science & Technology

    1993-09-01

    les kcouleinents incoinpressibles sur les profils L -a pr~sente m~thode num~rique montre que la simulation multi-corps, qui est un...de l ’&oulement du d𔄀chelle de discrdtisation, d’origine physique, introduit des m~me ordre que l ’~paisseur des couches limites sur le point de...hypersustentateurs. Enfin, les consequences des exigences de furtivite sur la forme des aeronefs - c’est it dire la creation de configurations telles que

  20. Contrôle du marché informel à l’heure de la mondialisation des échanges. Le cas des antirétroviraux au Chili

    PubMed Central

    Brousselle, Astrid; Morales, Cristián

    2013-01-01

    Résumé Les nouveaux médicaments pour le VIH/sida ont créé des besoins d’accessibilité aux traitements que les gouvernements n’ont pas toujours réussi à couvrir. Il en résulte l’émergence d’un marché informel des ARV. Par l’analyse de la situation au Chili, nous traitons des différents créneaux d’approvisionnement, des conséquences de l’existence d’un tel marché, ainsi que des moyens envisageables pour réduire les effets indésirables. Les aspects tant microéconomiques que macroéconomiques concernant le marché et l’accessibilité aux médicaments sont abordés. PMID:23997580

  1. The NASA high power carbon dioxide laser: A versatile tool for laser applications

    NASA Technical Reports Server (NTRS)

    Lancashire, R. B.; Alger, D. L.; Manista, E. J.; Slaby, J. G.; Dunning, J. W.; Stubbs, R. M.

    1976-01-01

    A closed-cycle, continuous wave, carbon dioxide high power laser has been designed and fabricated to support research for the identification and evaluation of possible high power laser applications. The device is designed to generate up to 70 kW of laser power in annular shape beams from 1 to 9 cm in diameter. Electric discharge, either self sustained or electron beam sustained, is used for excitation. This laser facility provides a versatile tool on which research can be performed to advance the state-of-the-art technology of high power CO2 lasers in such areas as electric excitation, laser chemistry, and quality of output beams. The facility provides a well defined, continuous wave beam for various application experiments, such as propulsion, power conversion, and materials processing.

  2. Opération multimode transverse des OPOs: des structures classiques aux corrélations quantiques

    NASA Astrophysics Data System (ADS)

    Martinelli, M.; Ducci, S.; Gigan, S.; Treps, N.; Maître, A.; Fabre, C.

    2002-06-01

    Nous démontrons la formation de structures transverses sur les faisceaux émis par un oscillateur paramétrique optique (OPO) de type II en configuration confocale. D'un point de vue classique nous mettons en évidence le caractère multimode transverse de telles structures. A travers l'étude des corrélations spatiales des faisceaux générés nous montrons que ces structures sont également multimodes d'un point de vue quantique.

  3. Electronic Messaging for the 90s (Les Messageries Electroniques des Annees 90)

    DTIC Science & Technology

    1993-05-01

    des autres unitds (un programme peut par exemple inclure un algorithme de 2. L CICULAIONDE ’INFRMAION recherche dans des donn~es...dit quc le rdseau, en particulier le r.dseau distant, cette coopdration homme /macbine. aifre des performances bien infirieures A celles des ordinateurs...dans ce sens, entre constructeurs d’ordinateurs, des opdrations traitementltransport. constructeurs didquipements de t~ l ~communications et exploitants de

  4. Study of laser heated propulsion devices. Part 1: Evaluation of laser devices, fuels and energy coupling mechanisms

    NASA Technical Reports Server (NTRS)

    Hofer, O. C.

    1982-01-01

    Closed cycle, CW waveform and short wavelength laser devices are desirable characteristics for laser propulsion. The choice of specific wavelengths for hydrogen fuel affects the operational conditions under which a laser supported absorption (LSA) wave is initiated and maintained. The mechanisms of initiating and maintaining LSA waves depend on the wavelength of the laser. Consequently, the shape and size of the hot core plasma is also dependent on wavelength and pressure. Detailed modeling of these mechanisms must be performed before their actual significance can be ascertained. Inverse bremsstrahlung absorption mechanism is the dominant mechanism for coupling energy into the plasma, but other mechanisms which are wavelength dependent can dictate the LSA wave plasma initiation and maintenance conditions. Multiphoton mechanisms become important at visible or shorter wavelengths. These are important mechanisms in creating the initial H2 gas breakdown and supplying the precursor electrons required to sustain the plasma.

  5. 120: THE CLINICAL EFFECTIVENESS AND COST-EFFECTIVENESS OF FRACTIONAL CO2 LASER IN ACNE SCARS AND SKIN REJUVENATION: A SYSTEMATIC REVIEW AND ECONOMIC EVALUATION

    PubMed Central

    Yaaghoobian, Barmak; Sadeghi-Ghyassi, Fatemeh; Hajebrahimi, Sakineh

    2017-01-01

    Background and aims Skin rejuvenation is one of high demand cosmetic interventions in Iran. Fractional CO2 Laser is a high power ablative laser which has variety of utilization in medicine including treatment of acne scars and rejuvenation. The aim of this study was to evaluate the safety, efficacy, and cost-effectiveness of Fractional CO2 Laser in comparison with other methods of rejuvenation and acne scar treatment. Methods A systematic database search including Medline (via OVID and PubMed), EMBASE, CINHAL, Cochrane Library, CRD, SCOPUS and Web of Science conducted. After screening search results, selected publications appraised by CASP and Cochrane Collaboration's tool for assessing risk of bias and eligible studies included in the systematic review. In economic evaluation, all costs and benefits analyzed from Iran ministry of health's perspective. Results From 2667 publications, two randomized control trials were eligible and included in the study. The affectivity and complications of Fractional CO2 laser were comparable with Er: YAG but Fractional CO2 laser was 14.7% (P=0.01) more effective than Q-Switched ND: YAG laser. Cost affectivity of this method was the same as other alternative lasers. Conclusions Fractional CO2 laser is an effective and safe method for curing several kinds of skin. Never the less there was not sufficient evidence to support its advantage. This device has equal or lower price in comparison to competent technologies except for the non- fractional ablative Co2 laser that has the same or lower price and comparable effects.

  6. Imagerie polarimétrique active : des applications militaires et duales

    NASA Astrophysics Data System (ADS)

    Goudail, François; Boffety, Matthieu; Leviandier, Luc; Vannier, Nicolas

    2017-12-01

    L'imagerie polarimétrique active permet de révéler des contrastes invisibles à l'oeil humain et aux caméras classiques. Elle peut étendre les capacités de décamouflage des systèmes d'imagerie active et améliorer la détection d'objets dangereux sur des pistes. Elle possède également de nombreuses applications duales dans des domaines tels que l'imagerie biomédicale ou la vision industrielle.

  7. Prise en compte des ``courants de London'' dans la modélisation des supraconducteurs

    NASA Astrophysics Data System (ADS)

    Bossavit, Alain

    1997-10-01

    A model is given, in variational form, in which volumic “Bean currents”, ruled by Bean's law, and surface “London currents” coexist. This macroscopic model generalizes Bean's one, by appending to the critical density j_c a second parameter, with the dimension of a length, similar to London's depth λ. The one-dimensional version of the model is investigated, in order to link this parameter with the standard observable H-M characteristics On propose un modèle, sous forme variationnelle, associant des “courants de Bean” volumiques, décrits par la loi de Bean, et des “courants de London”, surfaciques. Ce modèle macroscopique généralise celui de Bean, caractérisé par le courant critique j_c, et fait intervenir un second paramètre, homogène à une longueur, analogue au λ de London. La version unidimensionnelle du modèle est étudiée en détail de manière à relier ce paramètre à l'observation des caractéristiques H-M usuelles.

  8. Navigated macular laser decreases retreatment rate for diabetic macular edema: a comparison with conventional macular laser.

    PubMed

    Neubauer, Aljoscha S; Langer, Julian; Liegl, Raffael; Haritoglou, Christos; Wolf, Armin; Kozak, Igor; Seidensticker, Florian; Ulbig, Michael; Freeman, William R; Kampik, Anselm; Kernt, Marcus

    2013-01-01

    The purpose of this study was to evaluate and compare clinical outcomes and retreatment rates using navigated macular laser versus conventional laser for the treatment of diabetic macular edema (DME). In this prospective, interventional pilot study, 46 eyes from 46 consecutive patients with DME were allocated to receive macular laser photocoagulation using navigated laser. Best corrected visual acuity and retreatment rate were evaluated for up to 12 months after treatment. The control group was drawn based on chart review of 119 patients treated by conventional laser at the same institutions during the same time period. Propensity score matching was performed with Stata, based on the nearest-neighbor method. Propensity score matching for age, gender, baseline visual acuity, and number of laser spots yielded 28 matched patients for the control group. Visual acuity after navigated macular laser improved from a mean 0.48 ± 0.37 logMAR by a mean +2.9 letters after 3 months, while the control group showed a mean -4.0 letters (P = 0.03). After 6 months, navigated laser maintained a mean visual gain of +3.3 letters, and the conventional laser group showed a slower mean increase to +1.9 letters versus baseline. Using Kaplan-Meier analysis, the laser retreatment rate showed separation of the survival curves after 2 months, with fewer retreatments in the navigated group than in the conventional laser group during the first 8 months (18% versus 31%, respectively, P = 0.02). The short-term results of this pilot study suggest that navigated macular photocoagulation is an effective technique and could be considered as a valid alternative to conventional slit-lamp laser for DME when focal laser photocoagulation is indicated. The observed lower retreatment rates with navigated retinal laser therapy in the first 8 months suggest a more durable treatment effect.

  9. High-Power Laser Source Evaluation

    DTIC Science & Technology

    1998-07-01

    uniform:«»! had been:taped. A sample beam profile at the receiver Zerodur Au-coated mirror 20 cm diameter f/6 Diode laser Diode bars 1 21 m beam...amplifiers and mirrors . This is of concern to the NIF Project and the use of unconverted 1.06 p.m light to produce these x-ray sources might require...they may result in DSWA Final Report - 34 NWET ANNUAL REPORT - QDV-99-0001 undesirable conditions at the turning mirrors or ghosts in the up-beam

  10. Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics

    NASA Technical Reports Server (NTRS)

    Quagliaroli, T. M.; Laufer, G.; Krauss, R. H.; Mcdaniel, J. C., Jr.

    1992-01-01

    The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.

  11. Detection de la fin de la compaction des anodes par le son

    NASA Astrophysics Data System (ADS)

    Sanogo, Bazoumana

    L'objectif de ce projet etait de developper un outil de controle en temps reel du temps de compaction en se servant du son genere par le vibrocompacteur pendant le formage des anodes crues. Ainsi, une application a ete developpee pour l'analyse des sons enregistres. Des essais ont ete realises avec differents microphones pour une meilleure qualite des mesures et un a ete choisi pour la suite du projet. De meme, differents tests ont ete realises sur des anodes de laboratoire ainsi que des anodes a l'echelle industrielle afin de mettre en place une methode pour la detection du temps optimal necessaire au formage des anodes. Les travaux au laboratoire de carbone a l'Universite du Quebec a Chicoutimi (UQAC) ont consiste a l'enregistrement de son des anodes fabriquees sur place avec differentes configurations; et a la caracterisation de certaines anodes de l'usine. Les anodes fabriquees au laboratoire sont reparties en deux groupes. Le premier regroupe les anodes pour la validation de notre methode. Ce sont des anodes produites avec des temps de compaction differents. Le laboratoire de carbone a l'UQAC est unique et il est possible de produire des anodes avec les memes proprietes que celles des anodes industrielles. Par consequent, la validation initialement prevue a l'usine a ete effectuee avec les anodes de laboratoire. Le deuxieme groupe a servi a etudier les effets des matieres premieres sur le temps de compaction. Le type de coke et le type de brai ont constitue les differentes variations dans ce deuxieme groupe. Quant aux tests et mesures a l'usine, ils ont ete realises en trois campagnes de mesure. La premiere campagne en juin 2014 a servi a standardiser et a trouver le meilleur positionnement des appareils pour les mesures, a regler le logiciel et a faire les premieres mesures. Une deuxieme campagne en mai 2015 a fait l'objet d'enregistrement de son en classant les anodes selon differents temps de compaction. La troisieme et derniere campagne en decembre 2015 a

  12. Laser lipolysis with pulsed 1064 nm Nd:YAG laser for the treatment of gynecomastia.

    PubMed

    Rho, Yong Kwan; Kim, Beom Joon; Kim, Myeung Nam; Kang, Kweon Soo; Han, Hee Jin

    2009-12-01

    Lipolysis using laser is currently widely used for reducing localized fat. A 1064 nm neodynium-doped yttrium aluminum garnet (Nd:YAG) laser lipolysis was investigated in this study to evaluate its efficacy and safety in the treatment of gynecomastia. Five male patients diagnosed with gynecomastia were enrolled in this study, which was designed as a controlled split-breast trial. One breast of each patient was subjected to laser lipolysis and was then compared with a contralateral breast. Photographs and clinical assessments were obtained before the lipolysis, and at the fourth and eighth weeks thereafter. Computed tomography (CT) scan and ultrasound (US) imaging were used to evaluate the changes in the breasts' thicknesses. The mean chest circumference was found to have been significantly reduced 8 weeks after the laser lipolysis. The clinical outcomes of the laser lipolysis were considered favorable by both the patients and clinicians. The CT and US scans showed that the thicknesses of the treated right breasts reduced more than those of the left breasts were 8 weeks after the laser lipolysis. The side effects (pain, edema, and ecchymosis) were minimal and disappeared shortly after they first manifested. Limitations The limitations of this study are that it employed small treatment groups and short-term follow-up. This study demonstrated that gynecomastia can be treated effectively and safely through 1064 nm Nd:YAG laser lipolysis.

  13. Clinical efficacy of utilizing Ultrapulse CO2 combined with fractional CO2 laser for the treatment of hypertrophic scars in Asians-A prospective clinical evaluation.

    PubMed

    Lei, Ying; Li, Shi Feng; Yu, Yi Ling; Tan, Jun; Gold, Michael H

    2017-06-01

    Hypertrophic scarring is seen regularly. Tissue penetration of laser energy into hypertrophic scars using computer defaults from some lasers may be insufficient and penetration not enough. We have developed a treatment with an interrupted laser "drilling" by the Ultrapulse CO 2 (Manual Fractional Technology, MFT) and, a second pass, with fractional CO 2 . The MFT with fractional CO 2 lasers to treat hypertrophic scars is evaluated. A total of 158 patients with hypertrophic scars had three sessions of MFT with fractional CO 2 laser at 3-month intervals. Evaluations made before and 6 months after the 3rd treatment: (1) the Vancouver Scar Scale (VSS), (2) the University of North Carolina (UNC) Scar Scale, and (3) a survey of patient satisfaction. All data were analyzed using a t-test before and after treatment. The VSS score decreased from 9.35 to 3.12 (P<.0001), and the UNC Scar Scale score decreased from 8.03 to 1.62 (P<.0001). The overall satisfaction rate was 92%. No long-term complications occurred in the clinical trial. The interrupted laser drilling by MFT and a fractional CO2 laser had profound effects on the hypertrophic scars treated. It works by increasing the penetration depth of the CO 2 laser in the scar tissue, exerting more precise effects on the hypertrophic scars. MFT combined with fractional CO 2 laser has the potential to be a major advance in the treatment of hypertrophic scars. © 2017 Wiley Periodicals, Inc.

  14. Laser scatter in clinical applications

    NASA Astrophysics Data System (ADS)

    Luther, Ed; Geddie, William

    2008-02-01

    Brightfield Laser Scanning Imaging (BLSI) is available on Laser Scanning Cytometers (LSCs) from CompuCyte Corporation. Briefly, digitation of photodetector outputs is coordinated with the combined motions of a small diameter (typically 2 to 10 microns) laser beam scanning a specimen in the Y direction (directed by a galvanometer-driven scanning mirror) and the microscope stage motion in the X direction. The output measurements are assembled into a two-dimensional array to provide a "non-real" digital image, where each pixel value reports the amount of laser-scattered light that is obtained when the laser beam is centered on that location. Depending on the detector positions, these images are analogous to Differential Interference Contrast or Phase Contrast microscopy. We report the incorporation of the new laser scattering capabilities into the workflow of a high-volume clinical cytology laboratory at University Health Network, Toronto, Canada. The laboratory has been employing LSC technology since 2003 for immunophenotypic fluorescence analysis of approximately 1200 cytological specimens per year, using the Clatch methodology. The new BLSI component allows visualization of cellular morphology at higher resolution levels than is possible with standard brightfield microscopic evaluation of unstained cells. BLSI is incorporated into the triage phase, where evaluation of unstained samples is combined with fluorescence evaluation to obtain specimen background levels. Technical details of the imaging methodology will be presented, as well as illustrative examples from current studies and comparisons to detailed, but obscure, historical studies of cytology specimens based on phase contrast microscopy.

  15. Intraoral laser welding: ultrastructural and mechanical analysis to compare laboratory laser and dental laser.

    PubMed

    Fornaini, Carlo; Passaretti, Francesca; Villa, Elena; Rocca, Jean-Paul; Merigo, Elisabetta; Vescovi, Paolo; Meleti, Marco; Manfredi, Maddalena; Nammour, Samir

    2011-07-01

    The Nd:YAG laser has been used since 1970 in dental laboratories to weld metals on dental prostheses. Recently in several clinical cases, we have suggested that the Nd:YAG laser device commonly utilized in the dental office could be used to repair broken fixed, removable and orthodontic prostheses and to weld metals directly in the mouth. The aim of this work was to evaluate, using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and dynamic mechanical analysis (DMA), the quality of the weld and its mechanical strength, comparing a device normally used in dental laboratory and a device normally used in the dental office for oral surgery, the same as that described for intraoral welding. Metal plates of a Co-Cr-Mo dental alloy and steel orthodontic wires were subjected to four welding procedures: welding without filler metal using the laboratory laser, welding with filler metal using the laboratory laser, welding without filler metal using the office laser, and welding with filler metal using the office laser. The welded materials were then analysed by SEM, EDS and DMA. SEM analysis did not show significant differences between the samples although the plates welded using the office laser without filler metal showed a greater number of fissures than the other samples. EDS microanalysis of the welding zone showed a homogeneous composition of the metals. Mechanical tests showed similar elastic behaviours of the samples, with minimal differences between the samples welded with the two devices. No wire broke even under the maximum force applied by the analyser. This study seems to demonstrate that the welds produced using the office Nd:YAG laser device and the laboratory Nd:YAG laser device, as analysed by SEM, EDS and DMA, showed minimal and nonsignificant differences, although these findings need to be confirmed using a greater number of samples.

  16. Dépistage des maladies cardiovasculaires chez des étudiants de l'Université de Douala et influence des activités physiques et sportives

    PubMed Central

    Ewane, Marielle Epacka; Mandengue, Samuel Honoré; Priso, Eugene Belle; Tamba, Stéphane Moumbe; Ahmadou; Fouda, André Bita

    2012-01-01

    Introduction Les maladies cardiovasculaires (MCV) constituent l'une des principales causes de mortalité dans les pays en développement. Le dépistage de ces dernières chez des jeunes est un défi dans la lutte contre leur expansion. Le but de cette étude était de dépister ces maladies au sein d'une population jeunes d’étudiants camerounais. Methodes Deux mille six cent cinquante-huit étudiants de l'Université de Douala (23,6 ± 2,9 ans, sex-ratio H/F = 0,9) ont en Avril - Mai 2011 participé à une campagne de dépistage gratuit du diabète, de l'hypertension artérielle (HTA) et de l'obésité. Ils ont également été soumis à une d'enquête évaluant leur niveau en activités physiques et sportives (APS). Resultats 12,7% des participants avaient une pression artérielle (PA) ≥ 140/90 mmHg, 3,6% étaient obèses et 0,9% avaient une glycémie ≥1,26 g/L. Des corrélations ont été trouvées entre certains facteurs de risque (diabète, hypertension et obésité) et le niveau académique d'une part (r =0,366; p < 0,0001) et le temps passé devant la télévision d'autres part (r = 0,411; p < 0,0001). L‘APS était inversement corrélée à l‘âge (r =-0,015; p < 0,0001) et au temps passé devant la télévision (r = -0,059; p = 0,002). Conclusion La présence des MCV et leurs facteurs de risque mis en évidence dans cette étude réalisée en milieu estudiantin camerounais interpelle à une prévention et une éducation dans la lutte contre ces dernières. PMID:22655111

  17. In-vivo experimental evaluation of nonablative skin remodeling using a 1.54-μm laser with surface cooling

    NASA Astrophysics Data System (ADS)

    Mordon, Serge R.; Capon, Alexandre; Creusy, Collette; Fleurisse, Laurence; Buys, Bruno; Faucheux, Marc A.; Servell, Pascal

    2000-05-01

    Selective dermal remodeling using diode or 1.32 micrometer Nd:YAG lasers has been recently proposed for skin rejuvenation. This new technique consists in inducing collagen tightening and/or neocollagen synthesis without significant damage of the overlying epidermis. Such an approach requires (1) a cooling system in order to target dermal collagen with relatively good protection of the epidermal layer, (2) a specific wavelength for confining the thermal damage into the upper dermis (100 to 400 micrometer). Based on previous studies, demonstrating a better water absorption and a reduced melanin absorption at 1.54 micrometer compared to the 1.32 micrometer, this experimental study aimed to evaluate a new laser (co-doped Yb-Er:phosphate glass material, Aramis, Quantel-France) emitting at 1.54 micrometer. This laser was used in combination with the Dermacool system (Dermacool, Mableton, USA) in order to achieve epidermis cooling before, during and after irradiation. Male hairless rats were used for the study. Pulse train irradiation (1.1 J, 3 Hz, 30 pulses) and different cooling temperatures (+5 degree(s)C, 0 degree(s)C, -5 degree(s)C) were screened with clinical examination and histological evaluation at 1, 3, and 7 days after laser irradiation. The clinical effects showed that pulse train irradiation produced reproducible epidermal preservation and confinement of the thermal damage into the dermis. The different cooling temperatures did not provide detectable differences in terms of size and depth of thermal damage. New collagen synthesis was confirmed by a marked fibroblastic proliferation, detected in the lower dermis at D3 and clearly seen in the upper dermis at D7. This new laser appears to be a promising new tool for the treatment of skin laxity, solar elastosis, facial rhytids and mild reduction of wrinkles.

  18. A new fiber-optic non-contact compact laser-ultrasound scanner for fast non-destructive testing and evaluation of aircraft composites

    PubMed Central

    Pelivanov, Ivan; Buma, Takashi; Xia, Jinjun; Wei, Chen-Wei; O'Donnell, Matthew

    2014-01-01

    Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for non-destructive testing and evaluation of aircraft composites. The performance of the LU system is demonstrated on a composite sample with known defects. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed fiber laser delivering nanosecond laser pulses at a repetition rate up to 76 kHz rate with a pulse energy of 0.6 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals at the same point on the composite surface. A- and B-scans obtained with the Sagnac interferometer are compared to those made with a contact wide-band polyvinylidene fluoride transducer. PMID:24737921

  19. Evaluation of effectiveness of Er,Cr:YSGG laser for root canal disinfection: theoretical simulation of temperature elevations in root dentin.

    PubMed

    Zhu, L; Tolba, M; Arola, D; Salloum, M; Meza, F

    2009-07-01

    Erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) lasers are currently being investigated for disinfecting the root canal system. Prior to using laser therapy, it is important to understand the temperature distribution and to assess thermal damage to the surrounding tissue. In this study, a theoretical simulation using the Pennes bioheat equation is conducted to evaluate how heat spreads from the canal surface using an Er,Cr:YSGG laser. Results of the investigation show that some of the proposed treatment protocols for killing bacteria in the deep dentin are ineffective, even for long heating durations. Based on the simulation, an alternative treatment protocol is identified that has improved effectiveness and is less likely to introduce collateral damage to the surrounding tissue. The alternative protocol uses 350 mW laser power with repeating laser tip movement to achieve bacterial disinfection in the deep dentin (800 microm lateral from the canal surface), while avoiding thermal damage to the surrounding tissue (T<47 degrees C). The alternative treatment protocol has the potential to not only achieve bacterial disinfection of deep dentin but also shorten the treatment time, thereby minimizing potential patient discomfort during laser procedures.

  20. Airborne Visible Laser Optical Communications Program (AVLOC)

    NASA Technical Reports Server (NTRS)

    Ward, J. H.

    1975-01-01

    The design, development, and operation of airborne and ground-based laser communications and laser radar hardware is described in support of the Airborne Visible Laser Optical Communication program. The major emphasis is placed on the development of a highly flexible test bed for the evaluation of laser communications systems techniques and components in an operational environment.

  1. Validation d’indicateurs de la prise en charge des atteintes des fonctions cognitives dans les unités d’évaluation gériatrique

    PubMed Central

    Payot, Isabelle; Latour, Judith; Massoud, Fadi; Kergoat, Marie-Jeanne

    2007-01-01

    RÉSUMÉ OBJECTIF Analyser et adapter des indicateurs de qualité pour l’évaluation et la prise en charge des personnes avec atteinte des fonctions cognitives, dont la prévalence est très élevée dans les unités d’évaluation gériatrique au Québec. DEVIS Une méthode de type Delphi-modifiée. CONTEXTE Province de Québec. PARTICIPANTS Sept praticiens de milieux hospitaliers affiliés à 3 universités du Québec choisis pour leur compétence reconnue en démence et soins gériatriques. MÉTHODE Parmi les indicateurs développés en 2001 par la méthode RAND, 22 items sélectionnés pour leur pertinence au cours du processus d’évaluation et de prise en charge d’une atteinte des fonctions cognitives ont été adaptés aux conditions de pratique du milieu hospitalier québécois. Les indicateurs, accompagnés d’évidences de la littérature, ont été soumis, par la poste, à un panel d’experts. Chaque expert a coté, sur une échelle de 1 à 9, son degré d’accord à des affirmations concernant la validité, la qualité et la nécessité d’être inscrit dans le dossier médical. Pour qu’un indicateur soit retenu, il devait faire consensus selon les valeurs médianes, être situé dans le tertile supérieur et recevoir l’agrément des experts. Les indicateurs incertains étaient modifiés en fonction des commentaires des experts, puis soumis au même panel pour un second tour. RÉSULTATS Des 22 indicateurs soumis au premier tour, 21 ont été validés. Ils prenaient en compte le dépistage, l’investigation, l’évaluation, le traitement et le suivi. L’indicateur considéré comme incertain a été modifié puis accepté lors du second tour. CONCLUSION Cette étude a identifié 22 indicateurs pertinents pour l’évaluation et la prise en charge de l’atteinte des fonctions cognitives dans une unité d’évaluation gériatrique. Ils serviront de base à l’appréciation de la problématique de la démence, dans une étude ayant cours

  2. La planification préalable des soins pour les patients en pédiatrie

    PubMed Central

    2008-01-01

    RÉSUMÉ Les progrès médicaux et technologiques ont permis d’ac-croître les taux de survie et d’améliorer la qualité de vie des nourrissons, des enfants et des adolescents ayant des maladies chroniques mettant la vie en danger. La planifi-cation préalable des soins inclut le processus relié aux discussions sur les traitements essentiels au maintien de la survie et la détermination des objectifs des soins de longue durée. Les dispensateurs de soins pédiatriques ont l’obligation éthique d’assimiler cet aspect des soins médicaux. Le présent document de principes vise à aider les dispensateurs de soins à discuter de la planification préalable des soins des patients pédiatriques dans diverses situations. La planification préalable des soins exige des communications efficaces afin de clarifier les objectifs des soins et de s’entendre sur les traitements pertinents ou non pour réaliser ces objectifs, y compris les mesures de réanimation et les mesures palliatives.

  3. Histomorphometric Evaluation of the Effects of Various Diode Lasers and Force Levels on Orthodontic Mini Screw Stability

    PubMed Central

    Isman, Eren; Taner, Lale; Kurkcu, Mehmet

    2015-01-01

    Abstract Objective The purpose of this study was to evaluate the effects of different laser dose and force levels on the stability of orthodontic mini screws used for anchorage, by histomorphometric analyses. Background data Low-level laser therapy speeds up blood flow, improves the mechanism of the revitalization processes, reduces the risk of infection, boosts metabolic activities, and accelerates the healing of the damaged tissue. Although there are many research studies about low-level laser therapy applications in a variety of areas, no investigations were found concerning mini screw stability using various laser dose levels with different force level applications. Methods Seventeen New Zealand white rabbits were used. A total of 68 cylindrical, self-drilling orthodontic mini screws were threaded at the fibula. Experimental subjects were divided into six groups; force application was not performed in the first three groups, whereas 150g of force was applied via nickel-titanium closed-coil springs placed between two mini screws in the other three groups. Measurements of the initial torque values (10 Ncm) were manipulated by a digital portable torque gauge. Various low-level laser doses were applied to the groups during the postoperative 10 days. After 4 weeks, bone-to-implant contact and cortical bone thickness were histomorphometrically analyzed. Results In the 150g force plus 20 J/cm2 dosage group, the highest bone-to-implant contact values were observed. (p<0.05) There were no statistically significant correlations between cortical bone thickness and bone-to-implant contact values; on the other hand, no significant difference was found among the same groups in terms of cortical bone thickness values (p>0.05). Conclusions Low-level laser therapy was noticed to induce the mini screw–bone contact area. Low-level laser therapy may be a supplementary treatment method to increase the stability of the orthodontic mini screw. PMID:25594769

  4. La physique des bulles de champagne Une première approche des processus physico-chimiques liés à l'effervescence des vins de Champagne

    NASA Astrophysics Data System (ADS)

    Liger-Belair, G.

    2002-07-01

    bubbles collapsing at a free surface. But, to the best of our knowledge, and surprising as it may seem, no results concerning the collateral effects on adjoining bubbles of bubbles collapsing in a bubble monolayer have been reported up to now. Actually, effervescence in a glass of champagne ideally lends to a preliminary work with bubbles collapsing in a bubble monolayer. For a few seconds after pouring, the free surface is completely covered with a monolayer composed of quite monodisperse millimetric bubbles collapsing close to each others. We took high-speed photographs of the situation which immediately follows the rupture of a bubble cap in a bubble monolayer. Adjoining bubbles were found to be literally sucked and strongly stretched toward the lowest part of the cavity left by the bursting bubble, leading to unexpected and short-lived flower-shaped structures. Stresses in distorted bubbles (petals of the flower-shaped structure) were evaluated and found to be, at least, one order of magnitude higher than stresses numerically calculated in the boundary layer around an isolated single millimetric collapsing bubble. This is a brand-new and slightly counter-intuitive result. While absorbing the energy released during collapse, as an air-bag would do, adjoining bubble caps store this energy into their thin liquid film, leading finally to stresses much higher than those observed in the boundary layer around single millimetric collapsing bubbles. Further investigation should be conducted now, and especially numerically, in order to better understand the relative influence of each pertinent parameters (bubble size, liquid density and viscosity, effect of surfactant...) on bubble deformation. L'objectif général de cet ouvrage consacré à l'étude des processus physico- chimiques de l'effervescence des vins de Champagne était de décortiquer les différentes étapes de la vie d'une bulle de champagne en conditions réelles de consommation, dans une flûte. Nous r

  5. Analyse chronometrique intersexes de la resolution de la tache d'horizontalite des liquides

    NASA Astrophysics Data System (ADS)

    Berthiaume, Francois

    D'abondantes recherches ont demontre que la reussite a la tache d'horizontalite des liquides est en moyenne plus elevee chez les individus de sexe masculin que chez ceux de sexe feminin. Deux facteurs principaux ont ete proposes: il s'agit de la connaissance du principe physique de l'invariance de l'orientation des liquides et de certaines habiletes perceptives d'ordre visuel. Le but de la presente recherche est d'etablir la duree detaillee de la resolution de la tache d'horizontalite des liquides chez 185 filles et 180 garcons, ages de 15 a 19 ans et repartis en 8 groupes. Dans une version informatisee, le premier groupe trace la position de la surface de l'eau a l'interieur d'un contenant dans diverses inclinaisons et le deuxieme evalue si l'orientation d'une ligne y represente bien cette position; le troisieme groupe trace une horizontale dans un rectangle et le quatrieme juge si la ligne illustree y est bien horizontale. Quatre autres groupes executent respectivement les memes taches dans la version classique papier-crayon. Le temps accorde a la reflexion avant de commencer le trace, le temps de tracage comme tel et le temps de verification du trace complete sont calcules. Chez les groupes qui evaluent l'orientation d'une ligne sur support informatique, le temps requis pour y parvenir est note. Enfin, un questionnaire estime si les participants connaissent ou non le principe physique d'invariance de l'orientation de la surface d'un liquide. Les resultats revelent que cette connaissance est plus frequente chez les garcons dans l'ensemble des groupes. Dans le cas ou les sujets ont a tracer une ligne, les filles reussissent moins d'essais que les garcons s'il faut, sur support informatique, tracer la surface de l'eau dans un contenant incline ou a l'horizontale. Il en va de meme s'il faut, sur support papier, tracer une horizontale dans un contenant incline. Le trace de la surface de l'eau est plus exact chez les sujets connaissant le principe d'invariance et l

  6. CO laser angioplasty system: efficacy of manipulatable laser angioscope catheter

    NASA Astrophysics Data System (ADS)

    Arai, Tsunenori; Kikuchi, Makoto; Mizuno, Kyoichi; Sakurada, Masami; Miyamoto, Akira; Arakawa, Koh; Kurita, Akira; Nakamura, Haruo; Takeuchi, Kiyoshi; Utsumi, Atsushi; Akai, Yoshiro

    1992-08-01

    A percutaneous transluminal coronary angioplasty system using a unique combination of CO laser (5 micrometers ) and As-S infrared glass fiber under the guidance of a manipulatable laser angioscope catheter is described. The ablation and guidance functions of this system are evaluated. The angioplasty treatment procedure under angioscope guidance was studied by in vitro model experiment and in vivo animal experiment. The whole angioplasty system is newly developed. That is, a transportable compact medical CO laser device which can emit up to 10 W, a 5 F manipulatable laser angioscope catheter, a thin CO laser cable of which the diameter is 0.6 mm, an angioscope imaging system for laser ablation guidance, and a system controller were developed. Anesthetized adult mongrel dogs (n equals 5) with an artificial complete occlusion in the femoral artery and an artificial human vessel model including occluded or stenotic coronary artery were used. The manipulatability of the catheter was drastically improved (both rotation and bending), therefore, precise control of ablation to expand stenosis was obtained. A 90% artificial stenosis made of human yellow plaque in 4.0 mm diameter in the vessel was expanded to 70% stenosis by repetitive CO laser ablations of which total energy was 220 J. All procedures were performed and controlled under angioscope visualization.

  7. Children acceptance of laser dental treatment

    NASA Astrophysics Data System (ADS)

    Lazea, Andreea; Todea, Carmen

    2016-03-01

    Objectives: To evaluate the dental anxiety level and the degree of acceptance of laser assisted pedodontic treatments from the children part. Also, we want to underline the advantages of laser use in pediatric dentistry, to make this technology widely used in treating dental problems of our children patients. Methods: Thirty pediatric dental patients presented in the Department of Pedodontics, University of Medicine and Pharmacy "Victor Babeş", Timişoara were evaluated using the Wong-Baker pain rating scale, wich was administered postoperatory to all patients, to assess their level of laser therapy acceptance. Results: Wong-Baker faces pain rating scale (WBFPS) has good validity and high specificity; generally it's easy for children to use, easy to compare and has good feasibility. Laser treatment has been accepted and tolerated by pediatric patients for its ability to reduce or eliminate pain. Around 70% of the total sample showed an excellent acceptance of laser dental treatment. Conclusions: Laser technology is useful and effective in many clinical situations encountered in pediatric dentistry and a good level of pacient acceptance is reported during all laser procedures on hard and soft tissues.

  8. Comparison between sequentional treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism.

    PubMed

    Nilforoushzadeh, Mohammad Ali; Naieni, Farahnaz Fatemi; Siadat, Amir Hossein; Rad, Leila

    2011-11-01

    Laser systems that are commonly used for the treatment of hirsutism include the ruby laser (694 nm), the diode laser (800 nm), the alexandrite laser (755 nm) and the Nd:YAG laser (1084 nm). The diode laser and alexandrite laser are considered effective in treatment of hirsutism in dark-skinned patients. The response of hairs to these laser systems is variable and not complete. In this study, we compared the efficacy of these two laser systems for permanent hair removal. This was a randomized, controlled clinical trial that was performed with women of the age range 15-45 years old. After obtaining informed consent, the samples were randomized into two groups using random allocation software. The first group was treated with alexandrite laser alone (four sessions, two months apart). The second group was treated sequentially with diode laser for the first two sessions and alexandrite laser for the next two sessions. Overall, 111 patients (57 patients in the alexandrite laser group and 54 patients in the sequential diode-alexandrite laser group) were evaluated. There was no significant difference regarding mean of hair reduction between the two groups during the courses of treatment. Except for the first session, there was no significant difference regarding percent of patient satisfaction between the two groups (P value >0.05). Comparison between the two groups showed no significant difference one month, three months and six months after the last treatment (P value >0.05). Regarding the results of our study, there is no significant difference between sequential treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism. We suggest that in further studies, the efficacy of sequential treatment with other laser systems is evaluated against single treatment methods.

  9. [Study of combined effects of DES and EV on the proliferation of MCF-7 cells by two experimental designs].

    PubMed

    Liu, Qian; Lei, Bing-Li; An, Jing; Shang, Yu; Zhong, Yu-Fang; Kang, Jia; Wen, Yu

    2013-08-01

    The single toxicity of diethylstilbestrol (DES) and beta-estradiol 17-valerate (EV) and the joint toxicity of their binary mixtures in equiconcentration to the proliferation of MCF-7 cells were investigated, respectively. Additive index (AI) method was adopted to evaluate the joint toxicity effect. At the same time, 3 x 3 factorial experimental design was used to verify the joint toxiciy types derived from equiconcentration of DES and EV. The results show that the EC50 values of single EV and DES for 24, 48 and 72 h are 6.02, 0.40 and 0.33 nmol x L(-1) and 5.90, 6.98 and 2.90 nmol x L(-1), respectively. The EC50 values of the binary mixtures of DES and EV for 24, 48 and 72 h are 2.33, 0.71 and 0.39 nmol x L(-1). The binary joint effects of DES and EV for 24 h were synergistic, and the joint effects of DES and EV for 48 and 72 h were antagonistic. But synergistic and antagonistic effects are not strong; their values can be found close to the values of additive effects. Factorial experiment results show that combined effects of DES and EV to proliferation of MCF-7 cells for 24, 48 and 72 h three exposure periods are additive effect types. The consistent joint combined effect types can be drawn from both factorial experimental design and equiconcentration ratio of DES and EV to the proliferation of MCF-7 cells. However, the factorial experimental design is simpler and more convenient, and can avoid unnecessary mistakes due to the derivation of EC50 values.

  10. La microscopie ionique analytique des tissus biologiques

    NASA Astrophysics Data System (ADS)

    Galle, P.

    Proposed in 1960 by R. Castaing and G. Slodzian, secondary ion emission microanalysis is a microanalytical method which is now largely used for the study of inert material. The instrument called the analytical ion microscope can also be used for the study of biological spécimens ; images representing the distribution of a given stable or radioactive isotope in a tissue section are obtained with a resolution of 0.5 μm. Among the characteristics of this method, two are of particular interest in biological research : its capacity for isotopic analysis and its very high sensitivity which makes possible for the first time a chemical analysis of element at a very low or even at a trace concentration in a microvolume. Proposé en 1960 par R. Castaing et G. Slodzian, la microanalyse par émission ionique secondaire est une méthode qui permet, entre autre, d'obtenir des images représentant la distribution des isotopes présents à la surface d'un échantillon solide avec une résolution de 0,5 μm. D'intérêt très général, cette méthode a été d'abord largement utilisée pour l'étude des matériaux inertes. Elle offre en outre des possibilités entièrement nouvelles dans le domaine de la recherche biomédicale. L'instrument réalisé, le microscope ionique analytique présente deux caractéristiques particulièrement intéressantes pour la biologie : la possibilité d'analyse isotopique, et l'extrême sensibilité permettant de détecter et de localiser dans une coupe histologique des éléments à des concentrations très faibles voire à l'état de trace.

  11. An Enclosed Laser Calibration Standard

    NASA Astrophysics Data System (ADS)

    Adams, Thomas E.; Fecteau, M. L.

    1985-02-01

    We have designed, evaluated and calibrated an enclosed, safety-interlocked laser calibration standard for use in US Army Secondary Reference Calibration Laboratories. This Laser Test Set Calibrator (LTSC) represents the Army's first-generation field laser calibration standard. Twelve LTSC's are now being fielded world-wide. The main requirement on the LTSC is to provide calibration support for the Test Set (TS3620) which, in turn, is a GO/NO GO tester of the Hand-Held Laser Rangefinder (AN/GVS-5). However, we believe it's design is flexible enough to accommodate the calibration of other laser test, measurement and diagnostic equipment (TMDE) provided that single-shot capability is adequate to perform the task. In this paper we describe the salient aspects and calibration requirements of the AN/GVS-5 Rangefinder and the Test Set which drove the basic LTSC design. Also, we detail our evaluation and calibration of the LTSC, in particular, the LTSC system standards. We conclude with a review of our error analysis from which uncertainties were assigned to the LTSC calibration functions.

  12. DES daughters in France: experts' points of view on the various genital, uterine and obstetric pathologies, and in utero DES exposure.

    PubMed

    Clement, R; Guilbaud, E; Barrios, L; Rougé-Maillart, C; Jousset, N; Rodat, O

    2014-10-01

    Compensation of diethylstilbestrol exposure depends on the judicial system. In France, girls having been exposed to diethylstilbestrol are currently being compensated, and each exposure victim is being evaluated. Fifty-nine expert evaluations were studied to determine the causal relation between exposure to diethylstilbestrol and the pathologies attributable to diethylstilbestrol. The following were taken into consideration: age at the first signs of the pathology; age of the sufferer at the time of evaluation; the pathologies grouped into five categories: fertility disorders - cancers - mishaps during pregnancy - psychosomatic complaints - pathologies of "3rd generation DES victims"; submission of proof of DES exposure; the degree of causality determined (direct, indirect, ruled out). 61% of the cases related to fertility disorders, 28.8% to cancer pathologies (clear-cell adenocarcinoma), 18.6% to mishaps during pregnancy, 8.5% to disorders resulting from preterm delivery, and 3.4% to psychosomatic disorders. Some cases involved a combination of two types of complaints. Indirect causality was determined in 47.1% of the cases involving primary sterility, in 66.7% involving secondary sterility, and in 5 out of 6 cases of total sterility. There is direct causality between in utero diethylstilbestrol exposure and vaginal or cervical clear cell adenocarcinoma. Causality is indirect in the case of disorders linked to prematurity in third generation victims. Causality was determined by the experts on the basis of scientific criteria which attribute the presenting pathologies to diethylstilbestrol exposure. When other risk factors come into play, or when exposure is indirect (third generation), this causality is diminished. © IMechE 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. Evaluating the potential for internal injuries from a pulsed 3.8-micron laser

    NASA Astrophysics Data System (ADS)

    Johnson, Thomas E.; Fitzhugh, Dawn C.; McPherson, Nicole; Winston, Golda C. H.; Winston, Tridaugh D.; Randolph, Donald Q.

    2005-04-01

    The goal of this study is to determine if a high energy laser pulse can cause internal injury that cannot be grossly visualized. High power lasers are currently in development such as the Medical Free Electron Laser (MFEL), the Anti-Ballistic Laser (ABL) and the Tactical High Energy Laser (THEL) and the potential exists for human exposure. Little is known about the effects of these high output lasers on internal organs when a thoracic exposure occurs. This study utilized a 3.8 micron single 8 microsecond pulse laser for all exposures. Yucatan miniature pigs were exposed to a single pulse over the sternum. In addition, some animals were also exposed in the axillary region. Creatine phosphokinase (CPK) and troponin levels were measured prior to and post exposure to assess cardiac muscle damage. Gross and histologic changes were determined for the porcine skin, lung tissue, and cardiac muscle. This study explores if a greater than class 4 laser classification is warranted based on the potential for thoracic injury.

  14. Experimental diode laser-assisted microvascular anastomosis.

    PubMed

    Reali, U M; Gelli, R; Giannotti, V; Gori, F; Pratesi, R; Pini, R

    1993-05-01

    An experimental study to evaluate a diode-laser approach to microvascular end-to-end anastomoses is reported. Studies were carried out on the femoral arteries and veins of Wistar rats, and effective welding of vessel tissue was obtained at low laser power, by enhancing laser absorption with indocyanine green (Cardio-green) solution. The histologic and surgical effects of this laser technique were examined and compared with those of conventional microvascular sutured anastomoses.

  15. Pulse Compression Techniques for Laser Generated Ultrasound

    NASA Technical Reports Server (NTRS)

    Anastasi, R. F.; Madaras, E. I.

    1999-01-01

    Laser generated ultrasound for nondestructive evaluation has an optical power density limit due to rapid high heating that causes material damage. This damage threshold limits the generated ultrasound amplitude, which impacts nondestructive evaluation inspection capability. To increase ultrasound signal levels and improve the ultrasound signal-to-noise ratio without exceeding laser power limitations, it is possible to use pulse compression techniques. The approach illustrated here uses a 150mW laser-diode modulated with a pseudo-random sequence and signal correlation. Results demonstrate the successful generation of ultrasonic bulk waves in aluminum and graphite-epoxy composite materials using a modulated low-power laser diode and illustrate ultrasound bandwidth control.

  16. Approche à l’endroit des blessures traumatiques à la main en soins primaires

    PubMed Central

    Cheung, Kevin; Hatchell, Alexandra; Thoma, Achilleas

    2013-01-01

    Résumé Objectif Passer en revue la prise en charge initiale des blessures traumatiques communes à la main que voient les médecins de soins primaires. Sources des données Nous avons examiné les données cliniques probantes et les ouvrages spécialisés récents cernés par des recherches dans la base de données électronique MEDLINE. Nous avons utilisé l’opinion d’experts pour compléter les recommandations dans les domaines où les données scientifiques étaient rares. Message principal Les médecins de soins primaires sont couramment appelés à prendre en charge des patients victimes de blessures traumatiques à la main. Dans le contexte d’un cas clinique, nous examinons l’évaluation, le diagnostic et la prise en charge initiale des traumatismes communs à la main. La présentation et la prise en charge des blessures au lit de l’ongle, des amputations de l’extrémité du doigt, des doigts en maillet, des fractures à la main, des lacérations de tendons, des morsures et de la ténosynovite infectieuse seront aussi discutées. Les principes de la prise en charge des blessures traumatiques à la main comportent la réduction et l’immobilisation des fractures, la prescription d’imagerie radiographique post-réduction, l’obtention d’un recouvrement par les tissus mous, la prévention et le traitement des infections et l’assurance d’une prophylaxie antitétanique. Conclusion Il est essentiel d’assurer une évaluation et une prise en charge appropriées des blessures traumatiques à la main pour prévenir une morbidité considérable à long terme dans une population autrement en santé. La reconnaissance sans délai des blessures qui nécessitent une demande de consultation urgente ou rapide auprès d’un chirurgien spécialiste de la main est également critique.

  17. Comparative scanning electron microscope analysis of diode laser and desensitizing toothpastes for evaluation of efficacy of dentinal tubular occlusion.

    PubMed

    Reddy, Guntakala Vikram; Akula, Sushma; Malgikar, Suryakanth; Babu, Palaparthy Raja; Reddy, Gooty Jagadish; Josephin, Johnson Juliet

    2017-01-01

    The present study aims to evaluate the efficacy of diode laser alone and in combination with desensitizing toothpastes in occluding dentinal tubules (both partially occluded and completely occluded tubules) by scanning electron microscope (SEM). Fifty human teeth were extracted, cervical cavities were prepared and etched with 17% ethylenediaminetetraacetic acid, and smear layer was removed to expose the tubules. The teeth were divided into five groups: Group I - Application of NovaMin-formulated toothpaste, Group II - Application of Pro-Argin ™ -formulated toothpaste, Group III - Application of diode laser in noncontact mode, Group IV - NovaMin-formulated toothpaste followed by laser irradiation, and Group V - Pro-Argin ™ -formulated toothpaste followed by laser irradiation. After treatment, quantitative analysis of occluded dentinal tubules was done by SEM analysis. The mean values of percentages of total occlusion of dentinal tubules in Groups I, II, III, IV, and V were 92.73% ± 1.38, 90.67% ± 1.86, 96.57% ± 0.64, 97.3% ± 0.68, and 96.9% ± 6.08, respectively. Addition of diode laser (Groups III, IV, and V) yielded a significant occlusion of the dentinal tubules when compared to desensitizing toothpastes alone (Groups I and II). Diode laser (Group III) has shown more efficacy in occluding dentinal tubules when compared with desensitizing toothpastes which was statistically significant ( P < 0.05). Among the five groups, NovaMin + diode laser (Group IV) showed the highest percentage of occluded dentinal tubules.

  18. Intraluminal laser light source and external solder: in vivo evaluation of a new technique for microvascular anastomosis.

    PubMed

    Ott, Beat; Constantinescu, Mihai A; Erni, Dominique; Banic, Andrej; Schaffner, Thomas; Frenz, Martin

    2004-01-01

    Current laser-assisted end-to-end anastomoses are performed by irradiating the vessel wall from outside after additional fixation with three to six sutures. These sutures are needed to provide adequate approximation of the vessel stumps. We present a new laser soldering technique that is based on an intraluminal laser light source centered in a balloon catheter, and external application of a solder. This technique was applied in vivo in order to test its feasibility under clinical conditions. Seven white pigs were treated with a total of fourteen end-to-end laser-anastomoses of their saphenous arteries having outer diameters of 2 mm. The vessels were stented over an intraluminal balloon catheter, which was maximally dilated and which allowed for a precise approximation of the vascular stumps. An 808 nm diode laser was coupled into a specially designed optical fiber producing a 360 degrees radiation ring inside the balloon catheter. An indocyanine green (ICG) doped liquid albumin solder was applied on the external surface of the vascular stumps. Laser soldering was achieved by irradiating with a 808 nm laser diode for 75 seconds. Tightness of the anastomoses was evaluated by clamping the artery distal to the anastomosis for 1 hour, and patency was tested over an observation period of 3 hours, during which the animals were heparinized. Thereafter, the anastomoses were harvested for histomorphological examination. All anastomoses remained patent over the entire observation period. Some leakage was observed in three anastomoses, which was explained by a deviation of the illumination fiber from the center of the balloon leading to an inhomogeneous irradiation of the vessel wall. Histology revealed perfect adaptation of the vascular stumps. A segment of denaturated vascular collagen was observed, that corresponded to the irradiated, solder-covered zone. Patent, maximally dilated and well adapted microvascular anastomoses could be obtained without the need of stay sutures

  19. Three-dimensional laser window formation

    NASA Technical Reports Server (NTRS)

    Verhoff, Vincent G.

    1992-01-01

    The NASA Lewis Research Center has developed and implemented a unique process for forming flawless three-dimensional laser windows. These windows represent a major part of specialized, nonintrusive laser data acquisition systems used in a variety of compressor and turbine research test facilities. This report discusses in detail the aspects of three-dimensional laser window formation. It focuses on the unique methodology and the peculiarities associated with the formation of these windows. Included in this discussion are the design criteria, bonding mediums, and evaluation testing for three-dimensional laser windows.

  20. Evaluation of a laser scanning sensor on detection of complex shaped targets for variable-rate sprayer development

    USDA-ARS?s Scientific Manuscript database

    Sensors that can accurately measure canopy structures are prerequisites for development of advanced variable-rate sprayers. A 270° radial range laser sensor was evaluated for its accuracy to measure dimensions of target surfaces with complex shapes and sizes. An algorithm for data acquisition and 3-...

  1. Research for the jamming mechanism of high-frequency laser to the laser seeker

    NASA Astrophysics Data System (ADS)

    Zheng, Xingyuan; Zhang, Haiyang; Wang, Yunping; Feng, Shuang; Zhao, Changming

    2013-08-01

    High-frequency laser will be able to enter the enemy laser signal processing systems without encoded identification and a copy. That makes it one of the research directions of new interference sources. In order to study the interference mechanism of high-frequency laser to laser guided weapons. According to the principle of high-frequency laser interference, a series of related theoretical models such as a semi-active laser seeker coded identification model, a time door model, multi-signal processing model and a interference signal modulation processing model are established. Then seeker interfere with effective 3σ criterion is proposed. Based on this, the study of the effect of multi-source interference and signal characteristics of the effect of high repetition frequency laser interference are key research. According to the simulation system testing, the results show that the multi-source interference and interference signal frequency modulation can effectively enhance the interference effect. While the interference effect of the interference signal amplitude modulation is not obvious. The research results will provide the evaluation of high-frequency laser interference effect and provide theoretical references for high-frequency laser interference system application.

  2. Lasers in private dermatologic practice.

    PubMed

    Eastern, J S

    1986-04-01

    The author has collected and evaluated data from 464 cutaneous laser procedures performed on 315 patients over two and one-half years. All procedures were performed under local anesthesia in a private dermatology office. The quality of results obtained, the advantages and disadvantages of laser treatment for the treatment of cutaneous problems, comparison with more conventional therapies, and the future of the laser in dermatologic private practice are discussed.

  3. L'Infection Nosocomiale en Reanimation des Brules

    PubMed Central

    Siah, S.; Belefqih, R.; Elouennass, M.; Fouadi, F.E.; Ihrai, I.

    2009-01-01

    Summary L'infection nosocomiale bactérienne étant l'une des principales causes de morbidité et de mortalité chez le brûlé, nous avons réalisé une étude rétrospective portant sur 84 patients hospitalisés au sein du service de réanimation des brûlés de l'Hôpital Militaire d'Instruction Mohammed V de Rabat, sur une période de 3 ans, du premier janvier 2001 au 31 décembre 2003. Les critères d'infection nosocomiale étaient ceux du Center for Disease Control d'Atlanta de 1988. Les taux d'incidence ont été calculés. La population infectée a été comparée à celle non infectée. L'écologie bactérienne du service a été décrite comme aussi l'antibiotype. Il ressort de cette étude la survenue de 87 infections nosocomiales chez 27 patients. L'incidence cumulative était de 103 infections pour 1000 jours de traitement. Pour ce qui est des caractéristiques des infections bactériennes, les sites infectés étaient la peau (77%), le sang (13,8%), les voies urinaires (8%) et les poumons (1,1%). Les principaux germes étaient: Staphylococcus sp. (33,3%), Pseudomonas aeruginosa (23%), Enterococcus faecalis et Acinetobacter (8%). Les staphylocoques étaient méticillo-résistants dans 22,2% des cas. Le Pseudomonas et l'Acinetobacter étaient multirésistants (60%). Dans notre étude les facteurs prédictifs de survenue des infections nosocomiales que nous avons retenus après l'étude comparative des populations infectées et non infectées ont été l'âge, le body mass index, l'abbreviated burn severity index et le remplissage initial. En isolant ces paramètres, nous avons pu établir une équation à valeur prédictive de survenue d'infection nosocomiale chez le patient brûlé. PMID:21991158

  4. Methodes de caracterisation des proprietes thermomecaniques d'un acier martensitique =

    NASA Astrophysics Data System (ADS)

    Ausseil, Lucas

    Le but de l'etude est de developper des methodes permettant de mesurer les proprietes thermomecaniques d'un acier martensitique lors de chauffe rapide. Ces donnees permettent d'alimenter les modeles d'elements finis existant avec des donnees experimentales. Pour cela, l'acier 4340 est utilise. Cet acier est notamment utilise dans les roues d'engrenage, il a des proprietes mecaniques tres interessantes. Il est possible de modifier ses proprietes grâce a des traitements thermiques. Le simulateur thermomecanique Gleeble 3800 est utilise. Il permet de tester theoriquement toutes les conditions presentes dans les procedes de fabrication. Avec les tests de dilatation realises dans ce projet, les temperatures exactes de changement de phases austenitiques et martensitiques sont obtenues. Des tests de traction ont aussi permis de deduire la limite d'elasticite du materiau dans le domaine austenitique allant de 850 °C a 1100 °C. L'effet des deformations sur la temperature de debut de transformation est montre qualitativement. Une simulation numerique est aussi realisee pour comprendre les phenomenes intervenant pendant les essais.

  5. Optical radiation hazards of laser welding processes. Part 1: Neodymium-YAG laser.

    PubMed

    Rockwell, R J; Moss, C E

    1983-08-01

    High power laser devices are being used for numerous metalworking processes such as welding, cutting and heat treating. Such laser devices are totally enclosed either by the manufacturer or the end-user. When this is done, the total laser system is usually certified by the manufacturer following the federal requirements of the Code of Federal Regulations (CFR) 1040.10 and 10.40.11 as a Class I laser system. Similarly, the end-user may also reclassify an enclosed high-power laser into the Class I category following the requirements of the American National Standards Institute (ANSI) Z-136.1 (1980) standard. There are, however, numerous industrial laser applications where Class IV systems are required to be used in an unenclosed manner. In such applications, there is concern for both ocular and skin hazards caused by direct and scattered laser radiation, as well as potential hazards caused by the optical radiation created by the laser beam's interaction with the metal (i.e. the plume radiation). Radiant energy measurements are reported for both the scattered laser radiation and the resultant plume radiations which were produced during typical unenclosed Class IV Neodymium-YAG laser welding processes. Evaluation of the plume radiation was done with both radiometric and spectroradiometric measurement equipment. The data obtained were compared to applicable safety standards.

  6. Croissance des couches minces et des multicouches de matériaux supraconducteurs H Tboldmath_c : bilan et perspective

    NASA Astrophysics Data System (ADS)

    Contour, J. P.

    1994-11-01

    The main physical and chemical techniques of epitaxial growth of High T_c superconductor thin films are described together with their in situ analysis facilities and discussed with respect to their cost, sophistication and results (T_c, J_c growth defects, thickness and composition uniformity, crystallinity, electronic applications...). The future trends of the growth machines are then examined in connection with the present results and the development of superconductor electronics. Après la présentation des principales techniques de croissance physique et physicochimique de couches minces d'oxydes supraconducteurs à haute température critique, un bilan des résultats sera dressé par rapport aux différentes propriétés des films (transition résistive, courant critique, défauts de croissance, uniformité d'épaisseur et de composition, cristallinité...), aux difficultés de mise en œuvre et au coût de l'expérience. Les perspectives des différentes techniques seront ensuite examinées dans le cadre du développement potentiel d'une électronique utilisant les matériaux supraconducteurs H T_c.

  7. Wideband 1.064 micrometer detector evaluation. [for application to space laser communication systems

    NASA Technical Reports Server (NTRS)

    Green, S. I.

    1977-01-01

    Several types of communications detectors for use in a 400 Mbps 1.064 micrometer laser communication system were evaluated and characterized. The communication system Bit Error Rate (BER) performance was measured, and test results for the best detector of each type are summarized. The complete BER curves are presented. The 400 Mbps 1.064 micrometer communication system receiver test bed is described. The best performance levels which can be achieved by focusing the signal to diffraction limited spots on the photosensitive area are cited.

  8. Le contrôle des infections au cabinet du pédiatre

    PubMed Central

    2008-01-01

    RÉSUMÉ La transmission des infections au cabinet du pédiatre est de plus en plus préoccupante. Le présent document expose les voies de transmission des infections et les principes sous-jacents aux mesures actuelles pour contrôler les infections. Pour prévenir les infections, il faut bien concevoir le cabinet et adopter des politiques administratives et de triage convenables, de même que des pratiques de base pour les soins de tous les patients (p. ex., hygiène des mains, port de gants, de masques, de lunettes de protection et d’une blouse d’hôpital pour des interventions précises; nettoyage, désinfection et stérilisation convenables des surfaces et du matériel, y compris les jouets, et techniques d’asepsie en cas d’interventions effractives) et des précautions additionnelles en cas d’infections précises. Le personnel doit avoir reçu les vaccins pertinents, et les personnes infectées doivent respecter les politiques de restriction au travail.

  9. Laser-shocked energetic materials with metal additives: evaluation of detonation performance

    NASA Astrophysics Data System (ADS)

    Gottfried, Jennifer; Bukowski, Eric

    A focused, nanosecond-pulsed laser with sufficient energy to exceed the breakdown threshold of a material generates a laser-induced plasma with high peak temperatures, pressures, and shock velocities. Depending on the laser parameters and material properties, nanograms to micrograms of material is ablated, atomized, ionized and excited in the laser-induced plasma. The subsequent shock wave expansion into the air above the sample has been monitored using high-speed schlieren imaging in a recently developed technique, laser-induced air shock from energetic materials (LASEM). The estimated detonation velocities using LASEM agree well with published experimental values. A comparison of the measured shock velocities for various energetic materials including RDX, DNTF, and LLM-172 doped with Al or B to the detonation velocities predicted by CHEETAH for inert or active metal participation demonstrates that LASEM has potential for predicting the early time participation of metal additives in detonation events. The LASEM results show that reducing the amount of hydrogen present in B formulations increases the resulting detonation velocities

  10. Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1994-01-01

    Accomplishments in the following areas of research are presented: receiver performance study of spaceborne laser altimeters and cloud and aerosol lidars; receiver performance analysis for space-to-space laser ranging systems; and receiver performance study for the Mars Environmental Survey (MESUR).

  11. Diode laser (808 nm) applied to oral soft tissue lesions: a retrospective study to assess histopathological diagnosis and evaluate physical damage.

    PubMed

    Angiero, Francesca; Parma, Luisa; Crippa, Rolando; Benedicenti, Stefano

    2012-03-01

    The diode laser is today widely used in oral pathology to excise lesions; however, some controversy surrounds laser surgery, specifically the accuracy of pathological diagnosis and the control over thermal tissue damage. This study aimed to establish if physical damage induced by the diode laser could affect the histopathological diagnosis and to evaluate the damage caused to the resection margins. Between 2005 and 2010, at S. Gerardo Hospital, Milan, 608 cases of soft tissue lesions localized in the oral cavity (cheek, gingiva, buccal mucosa, tongue, and lips) were examined. Specimens were excised with an 808-nm diode laser, output 1.6-2.7 W, in continuous-wave mode with fibers of 320 μm. Specimens were fixed in 10% buffered formalin solution and examined separately under an optical microscope by two pathologists. In all of the specimens, changes to the epithelium, connective tissue and blood vessels, shape of incision damage, and overall width of modified tissues were evaluated. The data for specimens larger than 3 mm excised with the diode laser were not significant in terms of stromal changes or vascular stasis, while epithelial and stromal changes were significantly more frequent in specimens with a mean size below 3 mm; the diagnosis was not achievable in 46.15%. Our data show that the diode laser is a valid therapeutic instrument for excising oral lesions larger than 3 mm in diameter, but induces serious thermal effects in small lesions (mean size below 3 mm). However, from a clinical standpoint, it is suggested necessary that the specimens taken have in vivo a diameter of at least 5 mm in order to have a reliable reading of the histological sample.

  12. Comprendre la maltraitance des aînés en pratique familiale

    PubMed Central

    Yaffe, Mark J.; Tazkarji, Bachir

    2012-01-01

    Résumé Objectif Présenter ce qui constitue la maltraitance des aînés, ce dont les médecins de famille devraient être au courant, les signes et les symptômes laissant présager de mauvais traitements chez des adultes plus âgés, comment l’outil Elder Abuse Suspicion Index peut aider à détecter la maltraitance et les options qui existent pour réagir en cas de soupçons de maltraitance. Sources des données On a fait une recension dans MEDLINE, PsycINFO et Social Work Abstracts pour trouver des publications en français ou en anglais, de 1970 à 2011, à l’aide des expressions elder abuse, elder neglect, elder mistreatment, seniors, older adults, violence, identification, detection tools et signs and symptoms. Les publications pertinentes ont fait l’objet d’un examen. Message principal La maltraitance des aînés est une cause importante de morbidité et de mortalité chez les adultes plus âgés. Si les médecins de famille sont bien placés pour détecter des mauvais traitements infligés aux aînés, leurs taux réels de signalement de cas de maltraitance sont plus faibles que dans d’autres professions. Cette situation pourrait s’améliorer s’ils comprenaient mieux les genres d’agissements qui constituent de la maltraitance des aînés, ainsi que les signes et les symptômes observés au bureau qui pourraient pointer vers des cas de mauvais traitements. La détection de tels cas pourrait être facilitée par le recours à un court outil validé, comme l’Elder Abuse Suspicion Index. Conclusion Les médecins de famille peuvent jouer un rôle plus important dans la détection d’une éventuelle maltraitance des aînés. Une fois qu’on soupçonne de mauvais traitements, il existe dans la plupart des communautés des services sociaux ou des forces de l’ordre accessibles pour effectuer des évaluations plus approfondies et intervenir.

  13. Evaluation du niveau de connaissance des patients sur la gestion du traitement par les antis vitamines K dans le service de cardiologie de Ouagadougou

    PubMed Central

    Samadoulougou, André; Temoua Naibe, Dangwé; Mandi, Germain; Yameogo, Relwendé Aristide; Kabore, Elisé; Millogo, Georges; Yameogo, Nobila Valentin; Kologo, Jonas Koudougou; Thiam/Tall, Anna; Toguyeni, Boubacar Jean Yves; Zabsonre, Patrice

    2014-01-01

    Introduction Les antivitamines K (AVK), traitement anticoagulant oral le plus largement prescrit, posent un réel problème de santé publique du fait de leur risque iatrogène. L'objectif de cette étude était de préciser le niveau de connaissance des patients sur la gestion de leur traitement par les AVK. Méthodes Il s'est agi d'une enquête transversale descriptive réalisée au CHU-Yalgado Ouédraogo, sur une période de 03 mois : du 1er mars au 31 mai 2012. Un questionnaire a été administré aux patients bénéficiant d'un traitement AVK depuis au moins un mois. Résultats Soixante-dix patients ont été inclus dans l'étude dont 30 hommes. L'âge moyen était de 49 ans ± 16 ans. Les cardiopathies et la maladie thromboembolique veineuse justifiant l'institution du traitement AVK étaient retrouvées respectivement dans 58,6% et 41,4% des cas. Le nom de l'AVK et la raison exacte du traitement étaient connus respectivement dans 91,4% et 67,1% des cas. Plus de la moitié des patients (68,6%) savaient que les AVK rendaient le sang plus fluide. Quarante-six patients (65,7%) citaient l'INR comme examen biologique de surveillance du traitement et seulement 28 patients (40%) connaissaient les valeurs cibles. La majorité des patients ne connaissait pas les risques encourus en cas de surdosage (72,8%) et de sous-dosage (71,4%). Une automédication par anti-inflammatoire non stéroïdien était signalée par 18 patients (25,7%). Les choux (74,3%) et la laitue (62,9%), aliments à consommer avec modération, étaient les plus cités. Conclusion Les connaissances des patients sur la gestion des AVK étaient fragmentaires et insuffisantes pour assurer la sécurité et l'efficacité du traitement. La création d'un programme d'éducation thérapeutique sur les AVK s'avère alors nécessaire. PMID:25870741

  14. Laser ignition application in a space experiment

    NASA Technical Reports Server (NTRS)

    Liou, Larry C.; Culley, Dennis E.

    1993-01-01

    A laser ignition system is proposed for the Combustion Experiment Module on an orbiting spacecraft. The results of a design study are given using the scheduled 'Flame Ball Experiment' as the design guidelines. Three laser ignition mechanisms and wavelengths are evaluated. A prototype laser is chosen and its specifications are given, followed by consideration of the beam optical arrangement, the ignition power requirement, the laser ignition system weight, size, reliability, and laser cooling and power consumption. Electromagnetic interference to the onboard electronics caused by the laser ignition process is discussed. Finally, ground tests are suggested.

  15. Acquired acid resistance of human enamel treated with laser (Er:YAG laser and Co2 laser) and acidulated phosphate fluoride treatment: An in vitro atomic emission spectrometry analysis

    PubMed Central

    Mathew, Anju; Reddy, N. Venugopal; Sugumaran, D. K.; Peter, Joby; Shameer, M.; Dauravu, Liju Marcely

    2013-01-01

    Background: Dental caries is essentially a process of diffusion and dissolution. If the aspect of dissolution can be curtailed some degree of prevention can be achieved. Aims: The present study was carried out to evaluate and compare the effect of Er:YAG laser and Co2 laser irradiation combined with acidulated phosphate fluoride treatment on in vitro acid resistance of human enamel. Design: An in vitro study was carried out on 30 human premolars to evaluate the enamel's acid resistance using an atomic emission spectrometry analysis. Materials and Methods: A total of 60 enamel specimens were prepared from 30 human premolars and were randomly assigned to 6 groups: (1) Untreated (control); (2) 1.23% acidulated phosphate fluoride (APF) gel application alone for 4 min; (3) Er:YAG laser treatment alone; (4) Co2 laser treatment alone; (5) Er:YAG laser + APF gel application; (6) Co2 laser + APF gel application. The specimens were then individually immersed in 5 ml of acetate buffer solution (0.1 mol/L, pH 4.5) and incubated at 37°C for 24 h, and the acid resistance was evaluated by determining the calcium ion concentration using the atomic emission spectrometry. Statistical Analysis: An ANOVA model was constructed (P value of 0.05), followed by Tukey's test for multiple pair wise comparisons of mean values. Results: Significant differences were found between the control group and the test groups (P < 0.001). Conclusions: Combining acidulated phosphate fluoride with either Er:YAG or Co2 laser had a synergistic effect in decreasing the enamel demineralization more than either fluoride treatment or laser treatment alone. PMID:24015004

  16. Application of the verona coding definitions of emotional sequences (VR-CoDES) on a pediatric data set.

    PubMed

    Vatne, Torun M; Finset, Arnstein; Ørnes, Knut; Ruland, Cornelia M

    2010-09-01

    Adult patients present concerns as defined in the Verona Coding Definitions of Emotional Sequences (VR-CoDES), but we do not know how children express their concerns during medical consultations. This study aimed to evaluate the applicability of VR-CoDES to pediatric oncology consultations. Twenty-eight pediatric consultations were coded with the Verona Coding Definitions of Emotional Sequences (VR-CoDES), and the material was also qualitatively analyzed for descriptive purposes. Five consultations were randomly selected for reliability testing and descriptive statistics were computed. Perfect inter-rater reliability for concerns and moderate reliability for cues were obtained. Cues and/or concerns were present in over half of the consultations. Cues were more frequent than concerns, with the majority of cues being verbal hints to hidden concerns or non-verbal cues. Intensity of expressions, limitations in vocabulary, commonality of statements, and complexity of the setting complicated the use of VR-CoDES. Child-specific cues; use of the imperative, cues about past experiences, and use of onomatopoeia were observed. Children with cancer express concerns during medical consultations. VR-CoDES is a reliable tool for coding concerns in pediatric data sets. For future applications in pediatric settings an appendix should be developed to incorporate the child-specific traits. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Classification of 3 DES supernova with OzDES and DEVILS

    NASA Astrophysics Data System (ADS)

    Davies, L. J. M.; Driver, S. P.; Hashemizadeh, A.; Kushan, S. l.; Lidman, C.; Mannering, E.; Panther, F.; Sharp, R.; Sommer, N. E.; Tucker, B. E.; Zhang, B.; Mudd, D.; Swann, E. S.; Wiseman, P.; King, A.; Mould, J. R.; Calcino, J.; Bolejko, K.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Moller, A.; Yuan, F.; Davis, T. M.; Hinton, S.; Asorey, J.; Lewis, G. F.; Muthukrishna, D.; Uddin, S.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Macaulay, E.; Nichol, R.; Maartens, R.; Childress, M.; Prajs, S.; Smith, M.; Sullivan, M.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.

    2018-06-01

    We report new spectroscopic classifications by OzDES and DEVILS of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  18. Contaminants evaluation of Marais des Cygnes National Wildlife Refuge in Kansas and Missouri, USA

    NASA Astrophysics Data System (ADS)

    Allen, George T.; Nash, Tom J.; Janes, David E.

    1995-05-01

    At the new Marais des Cygnes National Wildlife Refuge in Linn County, Kansas, and Bates County, Missouri, USA, we evaluated long-lived contaminants before acquisition of the land for the refuge. We sampled sediments at 16 locations and fish at seven locations. The samples were analyzed for metals and for chlorinated hydrocarbon compounds. Selected sediment samples also were analyzed for aliphatic hydrocarbons. Arsenic concentrations in sediment samples from six locations were elevated compared to US norms, but arsenic was not detected in any fish composite. Mercury concentrations in largemouth bass from two locations were comparable to the 85th percentile concentrations in nationwide fish collections. Most sediment concentrations of other metals were unlikely to have detrimental effects on biota. No chlorinated hydrocarbons were detected in any sediment sample. Chlordane compound concentrations in fish composites from two sites at the eastern end of the sampling area were 0.127 and 0.228 μg/g wet weight, respectively, which are high enough to cause concern. Most aliphatic hydrocarbons detected were found at low concentrations and probably were natural in origin. We concluded that there are no serious contaminants concerns within the project area, but past use of arsenical pesticides may mean a legacy of elevated soil arsenic levels in parts of the area and some use of banned pesticides such as chlordane and DDT likely is still occurring near the refuge.

  19. ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers

    PubMed Central

    Muralikrishnan, B.; Sawyer, D.; Blackburn, C.; Phillips, S.; Borchardt, B.; Estler, W. T.

    2009-01-01

    Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests. PMID:27504211

  20. Efficacy of long pulse Nd:YAG laser versus fractional Er:YAG laser in the treatment of hand wrinkles.

    PubMed

    Robati, Reza M; Asadi, Elmira; Shafiee, Anoosh; Namazi, Nastaran; Talebi, Atefeh

    2018-04-01

    There are different modalities for hand rejuvenation. Fractional Er:YAG laser and long pulse Nd:YAG laser were introduced for treating hand wrinkles. We plan to compare fractional Er:YAG laser and long pulse Nd:YAG laser in a randomized controlled double-blind design with multiple sessions and larger sample size in comparison with previous studies. Thirty-three participants with hand wrinkles entered this study. They were randomly allocated to undergo three monthly laser treatments on each hand, one with a fractional Er:YAG laser and the other with a long pulse Nd:YAG laser. The evaluations included assessment of clinical improvement determined by two independent dermatologists not enrolled in the treatment along with measuring skin biomechanical property of hands using a sensitive biometrologic device with the assessment of cutaneous resonance running time (CRRT). Moreover, potential side effects and patients' satisfaction have been documented at baseline, 1 month after each treatment, and 3 months after the final treatment session. Clinical evaluation revealed both modalities significantly reduce hand wrinkles (p value < 0.05), with no significant difference between two lasers. Mean CRRT values also decreased significantly after the laser treatment compared to those of the baseline in both laser groups. There was no serious persistent side effect after both laser treatments. Both fractional Er:YAG and long pulse Nd:YAG lasers show substantial clinical improvement of hand skin wrinkles with no serious side effects. However, combination treatment by these lasers along with the other modalities such as fat transfer could lead to better outcomes in hand rejuvenation. IRCT2016032020468N4.

  1. Neuroprotective Treatment of Laser-Induced Retinal Injuries

    DTIC Science & Technology

    2000-10-01

    to evaluate the neuroprotective effect of memantine in our rat model of laser-induced retinal-lesions. Methods: Argon laser retinal lesions were...inflicted in the eyes of 36 pigmented rats. The treated group received memantine 10 mg/kg dissolved in saline, immediately after exposure to laser and then

  2. Airborne laser sensors and integrated systems

    NASA Astrophysics Data System (ADS)

    Sabatini, Roberto; Richardson, Mark A.; Gardi, Alessandro; Ramasamy, Subramanian

    2015-11-01

    The underlying principles and technologies enabling the design and operation of airborne laser sensors are introduced and a detailed review of state-of-the-art avionic systems for civil and military applications is presented. Airborne lasers including Light Detection and Ranging (LIDAR), Laser Range Finders (LRF), and Laser Weapon Systems (LWS) are extensively used today and new promising technologies are being explored. Most laser systems are active devices that operate in a manner very similar to microwave radars but at much higher frequencies (e.g., LIDAR and LRF). Other devices (e.g., laser target designators and beam-riders) are used to precisely direct Laser Guided Weapons (LGW) against ground targets. The integration of both functions is often encountered in modern military avionics navigation-attack systems. The beneficial effects of airborne lasers including the use of smaller components and remarkable angular resolution have resulted in a host of manned and unmanned aircraft applications. On the other hand, laser sensors performance are much more sensitive to the vagaries of the atmosphere and are thus generally restricted to shorter ranges than microwave systems. Hence it is of paramount importance to analyse the performance of laser sensors and systems in various weather and environmental conditions. Additionally, it is important to define airborne laser safety criteria, since several systems currently in service operate in the near infrared with considerable risk for the naked human eye. Therefore, appropriate methods for predicting and evaluating the performance of infrared laser sensors/systems are presented, taking into account laser safety issues. For aircraft experimental activities with laser systems, it is essential to define test requirements taking into account the specific conditions for operational employment of the systems in the intended scenarios and to verify the performance in realistic environments at the test ranges. To support the

  3. Caracterisation des proprietes dielectriques de materiaux composites a base de polyethylene terephtalate recycle =

    NASA Astrophysics Data System (ADS)

    Mebarki, Fouzia

    Cette etude vise a etudier la possibilite d'utiliser des materiaux composites a matrice thermoplastique pour des applications electriques comme les supports des systemes d'allumage dans les moteurs d'automobile. Nous nous interessons plus particulierement aux composites a base de polyethylene terephtalate (PET) recycle. Les isolants classiques comme le PET ne peuvent pas satisfaire toutes les exigences. L'introduction des renforts comme les fibres de verre et le mica peuvent ameliorer les caracteristiques mecaniques de ces materiaux. Toutefois, cette amelioration peut etre accompagnee d'une diminution des proprietes electriques surtout que ces materiaux doivent operer sous contraintes thermiques et electriques tres severes. Afin d'estimer la duree de vie de ces isolants, des essais de vieillissement accelere ont ete effectues a une frequence de 300Hz dans une plage de temperature allant de la temperature ambiante a 140°C. L'etude a haute temperature permettra de determiner la temperature de service des materiaux candidats. Des essais de la rupture dielectrique ont ete realises sur un grand nombre d'echantillon selon la norme ASTM D-149 relative aux mesures de rigidite dielectrique des isolants solides. Ces tests ont permis de deceler les echantillons problematiques et de verifier la qualite de ces isolants solides. Les differentes connaissances acquises lors de cette analyse ont servi a predire les performances des materiaux en service et vont permettre a la compagnie Groupe Lavergne d'apporter des ameliorations au niveau des formulations existantes et par la suite developper un materiau ayant les proprietes electriques et thermiques adequates pour ce type d'application. None None None None

  4. Simulation of laser-tattoo pigment interaction in a tissue-mimicking phantom using Q-switched and long-pulsed lasers.

    PubMed

    Ahn, K J; Kim, B J; Cho, S B

    2017-08-01

    Laser therapy is the treatment of choice in tattoo removal. However, the precise mechanisms of laser-tattoo pigment interactions remain to be evaluated. We evaluated the geometric patterns of laser-tattoo pigment particle interactions using a tattoo pigment-embedded tissue-mimicking (TM) phantom. A Q-switched (QS) neodymium-doped yttrium aluminum garnet laser was used at settings of 532-, 660-, and 1064-nm wavelengths, single-pulse and quick pulse-to-pulse treatment modes, and spot sizes of 4 and 7 mm. Most of the laser-tattoo interactions in the experimental conditions formed cocoon-shaped or oval photothermal and photoacoustic injury zones, which contained fragmented tattoo particles in various sizes depending on the conditions. In addition, a long-pulsed 755-nm alexandrite laser was used at a spot size of 6 mm and pulse widths of 3, 5, and 10 ms. The finer granular pattern of tattoo destruction was observed in TM phantoms treated with 3- and 5-ms pulse durations compared to those treated with a 10-ms pulse. We outlined various patterns of laser-tattoo pigment interactions in a tattoo-embedded TM phantom to predict macroscopic tattoo and surrounding tissue reactions after laser treatment for tattoo removal. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. De l'importance des orbites periodiques: Detection et applications

    NASA Astrophysics Data System (ADS)

    Doyon, Bernard

    L'ensemble des Orbites Periodiques Instables (OPIs) d'un systeme chaotique est intimement relie a ses proprietes dynamiques. A partir de l'ensemble (en principe infini) d'OPIs cachees dans l'espace des phases, on peut obtenir des quantites dynamiques importantes telles les exposants de Lyapunov, la mesure invariante, l'entropie topologique et la dimension fractale. En chaos quantique (i.e. l'etude de systemes quantiques qui ont un equivalent chaotique dans la limite classique), ces memes OPIs permettent de faire le pont entre le comportement classique et quantique de systemes non-integrables. La localisation de ces cycles fondamentaux est un probleme complexe. Cette these aborde dans un premier temps le probleme de la detection des OPIs dans les systemes chaotiques. Une etude comparative de deux algorithmes recents est presentee. Nous approfondissons ces deux methodes afin de les utiliser sur differents systemes dont des flots continus dissipatifs et conservatifs. Une analyse du taux de convergence des algorithmes est aussi realisee afin de degager les forces et les limites de ces schemes numeriques. Les methodes de detection que nous utilisons reposent sur une transformation particuliere de la dynamique initiale. Cette astuce nous a inspire une methode alternative pour cibler et stabiliser une orbite periodique quelconque dans un systeme chaotique. Le ciblage est en general combine aux methodes de controle pour stabiliser rapidement un cycle donne. En general, il faut connaitre la position et la stabilite du cycle en question. La nouvelle methode de ciblage que nous presentons ne demande pas de connaitre a priori la position et la stabilite des orbites periodiques. Elle pourrait etre un outil complementaire aux methodes de ciblage et de controle actuelles.

  6. Mecanismes d'ablation du silicium par laser ultrarapide amplifie par des nanostructures plasmoniques

    NASA Astrophysics Data System (ADS)

    Robitaille, Alexandre

    Ultrafast laser interaction with gold nanostructures deposited onto a silicon surface produces considerable field amplification that can result in the ablation of features with dimensions smaller than the diffraction limit. This field amplification in the near field of the nanostructures has been thoroughly investigated in the literature. However, while this is the main phenomenon that permits this nanoablation, energy deposition and diffusion processes cannot be neglected to interpret experimental results. In this work, we study plasmon-enhanced femtosecond laser ablation of silicon using gold nanorods and gold nanospheres to produce sub-diffraction limit holes. Atomic force microscopy and scanning electron microscopy of such features are done and hole depth as a function of fluence is measured. Especially for gold nanorods, hole shape is inconsistent with calculated field distribution. Field distribution alone would let us believe that each nanorod would produce two holes at its both ends. We show that using a model based on a differential equations system describing carriers excitation and diffusion, both shape and depth of the nanoholes can be predicted. Importance of the diffusion process is shown to arise from the extreme localization of the deposited energy around the nanostructure, compared to what is usually the case for conventional ablation of a surface. The characteristic shape of holes is revealed as a striking signature of the energy distribution through the electron-phonon carrier density dependant interaction.

  7. Activity of [des-Aspartyl1]-Angiotensin II in Primary Aldosteronism

    PubMed Central

    Carey, Robert M.; Ayers, Carlos R.; Vaughan, E. Darracott; Peach, Michael J.; Herf, Steven M.

    1979-01-01

    This study describes the effects of [des-Aspartyl1]-angiotensin II ([des-Asp]-AII) on blood pressure and aldosterone production in patients with primary aldosteronism due to aldosterone-producing adrenal adenoma (APA) and idiopathic adrenal hyperplasia (IHA), and in normotensive control subjects. 10 patients with primary aldosteronism, 7 with APA and 3 with IHA, and 6 normotensive control subjects were placed on a constant 150-meq sodium diet for 4 days. [des-Asp]-AII was infused for 30 min at 6, 12, and 18 pmol/kg per min. Three groups of patients were identified on the basis of aldosterone response to [des-Asp]-AII. Group I, composed of normotensive control subjects, showed incremental increases in plasma aldosterone concentration from 6±1 to 14±3 ng/100 ml (P < 0.01) with [des-Asp]-AII infusion. Group II, composed of patients with primary aldosteronism, showed incremental increases in plasma aldosterone concentration from 33±8 to 65±13 ng/100 ml (P < 0.05) with 12 pmol/kg per min of [des-Asp]-AII. Group III, also composed of patients with primary aldosteronism, showed no increase of plasma aldosterone concentration with [des-Asp]-AII. Groups I and II showed similar percentage increases in plasma aldosterone concentration (P = NS). Group III showed significantly lower aldosterone responses than group I (P < 0.01). Group II included all patients with IHA and two patients with APA. Group III included only patients with APA. The blood pressure responses to [des-Asp]-AII of subjects in group I did not differ significantly from those of groups II or III. Thus, patients with IHA and a subgroup of patients with APA showed responsiveness to [des-Asp]-AII which was limited to adrenal cortical stimulation of aldosterone biosynthesis. This suggests that adrenal responsiveness to angiotensin is a major control mechanism in some forms of primary aldosteronism. The differential adrenal responsiveness to [des-Asp]-AII in patients with APA indicates either that there are two

  8. Economic evaluation of drug-eluting stents in coronary angioplasty.

    PubMed

    Santos, Ricardo; Pereira, Hélder

    2005-11-01

    Coronary angioplasty has revolutionized the treatment of coronary artery disease, from the first balloon angioplasty to the current era of drug-eluting stents (DES), which were developed to eliminate the bare metal stent's (BMS) Achilles' heel, restenosis. DES have an extremely low restenosis rate but are significantly more expensive and need more prolonged dual antiplatelet therapy. Restenosis has a generally benign prognosis and is not associated with higher mortality or major adverse cardiovascular events, which has limited the penetration of DES, whose only advantage is the reduction of restenosis. Economic evaluation of DES is therefore of paramount importance for assessing their appropriate use. In randomized trials in which they are compared with BMS, economic evaluation is advantageous for DES, with good cost-effectiveness ratios for both cost per quality-adjusted life year (QALY) and cost per revascularization avoided. However, these trials have two major limitations--the angiographic follow-up protocol and selection of patients with lower risk--and so their results do not accurately reflect reality. Other studies with unselected populations and cost-effectiveness models show that there is an economic advantage in the use of DES in groups with higher risk of restenosis, but not for the whole population undergoing angioplasty. Use of DES will be more appropriate if we can identify populations with a higher likelihood of restenosis, because these are the patients that will benefit most from their use and in whom they will be economically advantageous.

  9. Comparative scanning electron microscope analysis of diode laser and desensitizing toothpastes for evaluation of efficacy of dentinal tubular occlusion

    PubMed Central

    Reddy, Guntakala Vikram; Akula, Sushma; Malgikar, Suryakanth; Babu, Palaparthy Raja; Reddy, Gooty Jagadish; Josephin, Johnson Juliet

    2017-01-01

    Background: The present study aims to evaluate the efficacy of diode laser alone and in combination with desensitizing toothpastes in occluding dentinal tubules (both partially occluded and completely occluded tubules) by scanning electron microscope (SEM). Materials and Methods: Fifty human teeth were extracted, cervical cavities were prepared and etched with 17% ethylenediaminetetraacetic acid, and smear layer was removed to expose the tubules. The teeth were divided into five groups: Group I – Application of NovaMin-formulated toothpaste, Group II – Application of Pro-Argin™-formulated toothpaste, Group III – Application of diode laser in noncontact mode, Group IV – NovaMin-formulated toothpaste followed by laser irradiation, and Group V – Pro-Argin™-formulated toothpaste followed by laser irradiation. After treatment, quantitative analysis of occluded dentinal tubules was done by SEM analysis. Results: The mean values of percentages of total occlusion of dentinal tubules in Groups I, II, III, IV, and V were 92.73% ± 1.38, 90.67% ± 1.86, 96.57% ± 0.64, 97.3% ± 0.68, and 96.9% ± 6.08, respectively. Addition of diode laser (Groups III, IV, and V) yielded a significant occlusion of the dentinal tubules when compared to desensitizing toothpastes alone (Groups I and II). Conclusion: Diode laser (Group III) has shown more efficacy in occluding dentinal tubules when compared with desensitizing toothpastes which was statistically significant (P < 0.05). Among the five groups, NovaMin + diode laser (Group IV) showed the highest percentage of occluded dentinal tubules. PMID:29398853

  10. Combustion of Solid Propellants (La Combustion des Propergols Solides)

    DTIC Science & Technology

    1991-07-01

    cin~tiques initiales. Il relatives A Ia granulom ~trie ct la surface eat s~me possible dWaller plus loin et sp~cifique des catalyseurs existent, il est...grand nombro do vari~t~s granulom ~triques des proporgols. On pout ainsi observer uno mont donc utilis~es induatriellemont pour notte influence du temps...et do la ajuster la vitosso des vari~tds do tempdrature do laminage sur la diminution granulom ~trie moyenno 400, 200, 100, 10, 3 de l’exposant do

  11. Evaluating the coherence and time-domain profile of quantum cascade laser frequency combs

    DOE PAGES

    Burghoff, David; Yang, Yang; Hayton, Darren J.; ...

    2015-01-01

    Recently, much attention has been focused on the generation of optical frequency combs from quantum cascade lasers. We discuss how fast detectors can be used to demonstrate the mutual coherence of such combs, and present an inequality that can be used to quantitatively evaluate their performance. We discuss several technical issues related to shifted wave interference Fourier Transform spectroscopy (SWIFTS), and show how such measurements can be used to elucidate the time-domain properties of such combs, showing that they can possess signatures of both frequency-modulation and amplitude-modulation.

  12. Histologic and SEM evaluation of caries removal and restoration in enamel and dentin using a pulsed fiber optic delivered Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    White, Joel M.; Goodis, Harold E.; Kudler, Joel J.; Eakle, W. S.; Neev, Joseph

    1994-09-01

    The pulsed Nd:YAG laser has been proposed as an alternative to the dental handpiece for caries removal in enamel and dentin. The purpose of this study was to systematically evaluate, in vitro, the process of caries removal and restoration in enamel and dentin. The effectiveness of this device was investigated utilizing scanning electron microscopy to determine the behavior of dentin after laser treatment of artificially created carious lesions in dentin. Histologic sections of extracted teeth after laser treatment and restoration demonstrated successful caries removal and restoration using the pulsed fiber optic delivered Nd:YAG laser as compared to both high and low speed rotary instrumentation. The adjacent enamel and dentin were unaffected by the laser irradiation although slight carbonization was seen on the dentin surface. Thermocouples placed in the pulp chamber during caries removal confirmed previous studies that showed laser parameters up to 1 W and 10 Hz being the same as conventional caries removal in the amount of heat generated which reaches the pulp. The addition of air/water coolant decreased pulpal temperature.

  13. Comparative Evaluation of the Effects of Nd:YAG Laser and a Desensitizer Agent on the Treatment of Dentin Hypersensitivity: A Clinical Study

    PubMed Central

    Lopes, Anely Oliveira

    2013-01-01

    Abstract Objective: The aim of this randomized longitudinal clinical study was to assess different treatment protocols for dentin hypersensitivity with high-power laser, desensitizing agent, and its association between high-power laser and desensitizing agent, for a period of 6 months. Background data: The literature shows a lack of treatment for dentin hypersensitivity, and lasers are contemporary alternatives. Methods: After inclusion and exclusion analysis, volunteers were selected. The lesions were divided into three groups (n=10): G1, Gluma Desensitizer (Heraeus Kulzer); G2, Nd:YAG Laser (Power Laser™ ST6, Lares Research®) contact mode, laser protocol of 1.5 W, 10 Hz, and 100 mJ,≈85 J/cm2, four irradiations performed, each for 15 sec, in mesiodistal and occluso-apical directions, totaling 60 sec of irradiation with intervals of 10 sec between them; G3, Nd:YAG Laser+Gluma Desensitizer. The level of sensitivity to pain of each volunteer was analyzed by visual analog scale (VAS) using cold air stimuli and exploratory probe 5 min, 1 week, and 1, 3, and 6 months after treatment. Data were collected and subjected to statistical analysis that detected statistically significant differences between the various studied time intervals of treatments (p>0.05). Results: For the air stimulus, no significant differences were found for each time interval. For the long-term evaluation, all groups showed statistical differences (p>0.05), indicating that for G2 and G3, this difference was statistically significant from the first time of evaluation (post 1), whereas in G1, the difference was significant from the post 2 evaluation (1 week). Comparison among groups using the probe stimulation showed significant differences in pain (p<0.001). Only in G1 and G3 did this difference become significant from post 01. Conclusions: All protocols were effective in reducing dentinal hypersensitivity after 6 months of treatment; however, the association of Nd:YAG and Gluma

  14. Transmyocardial laser revascularization with a high-power (800 W) CO2 laser: clinical report with 50 cases

    NASA Astrophysics Data System (ADS)

    Qu, Zheng; Zhang, Zhaoguang; Ye, Jianguang; Yu, Jianbo

    1999-09-01

    This paper reports the clinical experience in transmyocardial laser revascularization (TMLR) with high power CO2 laser and evaluates the preliminary results of TMLR. TMLR may improve angina pectoris and myocardial perfusion significantly. To switch on the laser in proper order may be helpful to shorten duration of surgery. A gentle removal of fat on the apex may increase the successful transmyocardial penetration.

  15. Le syndrome des enfants battus: aspects cliniques et radiologiques

    PubMed Central

    Jlalia, Zied; Znaigui, Talel; Smida, Mahmoud

    2016-01-01

    La maltraitance physique des enfants ou le syndrome des enfants battus est responsable de plus de 75.000 décès par an en France. Ce problème de santé publique reste sous diagnostiqué en Tunisie et dans le monde. Le chemin a été laborieux pour la reconnaissance du syndrome des enfants battus dans certaines sociétés même occidentales. Nous avons voulus exposer ce problème aux praticiens afin qu'il soit mieux diagnostiqué et pris en charge. La maltraitance physique des enfants est appelée à tort syndrome de Silverman qui ne regroupe en fait que les lésions squelettiques chez ces enfants tels que les fractures. Mots clés: Fracture, maltraitance, enfant, neuro-radiologie PMID:27642408

  16. Evaluation de L’Effet du Vieillissement des Equipages sur les Consequences du Decalage Horaire (Evaluation of Crew Members Aging on Jet-Lag Consequences)

    DTIC Science & Technology

    2000-08-01

    Ergonomia , 1987, 30, 13 79- physique que psychologique. Cela tend A damontrer que 1393. dans des conditions militaires op~rationnelles, les 2...melatonin. Ergonomia , 1987, 30, 1379- 1393. 2 - BLOIS R, FEINBERG I., GAILLARD J.M., KUPFER D.J. and WEBB W.B. Sleep in normal and pathological aging

  17. Mesure Objective De L'attenuation et De L'effet D'occlusion Des Protecteurs Auditifs a Partir Des Potentiels Evoques Stationnaires et Multiples =

    NASA Astrophysics Data System (ADS)

    Valentin, Olivier

    Selon l'Organisation mondiale de la sante, le nombre de travailleurs exposes quotidiennement a des niveaux de bruit prejudiciables a leur audition est passe de 120 millions en 1995 a 250 millions en 2004. Meme si la reduction du bruit a la source devrait etre toujours privilegiee, la solution largement utilisee pour lutter contre le bruit au travail reste la protection auditive individuelle. Malheureusement, le port des protecteurs auditifs n'est pas toujours respecte par les travailleurs car il est difficile de fournir un protecteur auditif dont le niveau d'attenuation effective est approprie a l'environnement de travail d'un individu. D'autre part, l'occlusion du canal auditif induit une modification de la perception de la parole, ce qui cree un inconfort incitant les travailleurs a retirer leurs protecteurs. Ces deux problemes existent parce que les methodes actuelles de mesure de l'effet d'occlusion et de l'attenuation sont limitees. Les mesures objectives basees sur des mesures microphoniques intra-auriculaires ne tiennent pas compte de la transmission directe du son a la cochlee par conduction osseuse. Les mesures subjectives au seuil de l'audition sont biaisees a cause de l'effet de masquage aux basses frequences induit par le bruit physiologique. L'objectif principal de ce travail de these de doctorat est d'ameliorer la mesure de l'attenuation et de l'effet d'occlusion des protecteurs auditifs intra-auriculaires. L'approche generale consiste a : (i) verifier s'il est possible de mesurer l'attenuation des protecteurs auditifs grâce au recueil des potentiels evoques stationnaires et multiples (PEASM) avec et sans protecteur auditif (protocole 1), (ii) adapter cette methodologie pour mesurer l'effet d'occlusion induit par le port de protecteur auditifs intra-auriculaires (protocole 2), et (iii) valider chaque protocole par l'intermediaire de mesures realisees sur sujets humains. Les resultats du protocole 1 demontrent que les PEASM peuvent etre utilises pour

  18. Fractional non-ablative laser treatment at 1410 nm wavelength for periorbital wrinkles - reviscometrical and clinical evaluation.

    PubMed

    Augustyniak, Anna; Rotsztejn, Helena

    2016-10-01

    The aim of the research was to establish the influence of 1410-nm fractional non-ablative laser treatment on skin aging in the eye area. The reviscometer reference test is an objective method of estimating the flexibility of the skin. The photographic records were used as the auxiliary method of the therapy quality effectiveness. The study involved the group of 13 people (12 females and 1 male, aged 33-47 with prototype II and III according to the Fitzpatrick scale), who underwent two sessions of fractional non-ablative laser therapy (wavelength of 1410 nm) with a 2-week interval. In order to evaluate the effectiveness of the quality of the treatment a reviscometer probe was used to measure the skin elasticity (Reviscometer RVM 600). The measurements were taken twice: directly before and two weeks after the treatment. Furthermore, to facilitate the clinical evaluation an anonymous photographical documentation was prepared. An improvement of the skin flexibility in the eye area was observed and the fact was confirmed by values obtained using the reviscometer probe (significant statistic differences: P < 0.0001) as well as clinical assessment based on photographical records. On the basis of the reviscometer measurements analysis and photographical records, 1410-nm fractional non-ablative laser treatment appears to be an efficient method contributing to the improvement of the skin flexibility of the eyes area as well as to the reduction of the number of wrinkles. The post-treatment observation proves that the method is well-tolerated in the sensitive eyes area and does not cause any significant side effects.

  19. Enhancement of endothelialisation of coronary stents by laser surface engineering.

    PubMed

    Li, Lin; Mirhosseini, Nazanin; Michael, Alun; Liu, Zhu; Wang, Tao

    2013-11-01

    Coronary stents have been widely used in the treatment of coronary heart disease. However, complications have hampered the long-term success of the device. Bare-metal stents (BMS) have a high rate of restenosis and poor endothelialisation. The drug-eluting stents (DES), although dramatically reduce restenosis, significantly prevent endothelialisation leading to late thrombosis and behave the same way as BMS after drug releasing. Rapid adhesion and growth of endothelial cells on the stent surface is a key process for early vascular healing after coronary stenting which contributes to the reduction of major complications. Surface properties manipulate cell growth and directly determine the success and life-span of the implants. However, the ideal surface properties of coronary stents are not yet fully understood. The objective of this research is to understand how surface micro/nano textures and associated material chemistry changes generated by a laser beam affect the behavior of endothelial cells on bare metal 316L stents. A high power laser beam was applied to modifying the surface properties of 316L coronary stent material and the commercial coronary stents, followed by examination of the adhesion and proliferation of human coronary endothelial cells that were growing on the surfaces. Surface properties were examined by scanning electron microscopy, contact angle measurement, and X-ray photoelectron spectroscopy. A novel surface with combined micro/nano features was created on stent material 316L and coronary stent with a specific surface chemistry. This surface gives rise to a threefold increase in the adhesion and eightfold increase in the proliferation of endothelial cells. Interestingly, such effects were only observed when the surface texture was produced in the nitrogen atmosphere suggesting the importance of the surface chemistry, including the dramatic increase of chromium nitride, for the interaction of endothelial cells with the material surface. This

  20. Results of the trials and light-delivery evaluation at low-level laser therapy of acute and chronic pain

    NASA Astrophysics Data System (ADS)

    Roeva, Tatiana; Petrov, Todor S.; Minkovski, Nikolai I.

    2004-06-01

    Although the low-level laser therapy (LLLT) is accepted in the clinical practice, its efficiency is still questionable because of the unclear mechanisms of LLLT action. This work presents the results of LLLT applied to volunteers who need recovery from trauma or suffer from rheumatic diseases, inflammatory disorders, etc. The control group we used for comparison consisted of patients being treated by conventional therapy that included massage and acupuncture needles. The effectiveness of the LLLT was graded under four categories. Short-term and long-term side effects as well as conditions responding only to LLLT were recorded. The successful treatments were up to 70%, which coincided with the result of the control group. The LLLT was performed with a GaAs laser system SIX LASER IR - Bulgaria provided with additional set of six light CW emitting diodes to scan a larger area of a tissue surface. To evaluate the light delivery inside the tissue, the spatial maps of the light spot at the laser output in different operating regimes were measured. On their basis, the absorbed dose was calculated both in the boundary layer under the tissue surface and in depth using a reduced variance Monte-Carlo code.

  1. Evaluation of an Al-Ce alloy for laser additive manufacturing

    DOE PAGES

    Plotkowski, A.; Rios, O.; Sridharan, N.; ...

    2016-12-27

    Our present research in metal additive manufacturing (AM) focuses on designing processing parameters around existing alloys designed for traditional manufacturing. However, to maximize the benefits of AM, alloys should be designed to specifically take advantage of the unique thermal conditions of these processes. Furthermore, our study focuses on the development of a design methodology for alloys in AM, using a newly developed Al-Ce alloy as an initial case study. To evaluate the candidacy of this system for fusion based additive manufacturing, single-line laser melts were made on cast Al-12Ce plates using three different beam velocities (100, 200, and 300 mm/min).more » The microstructure was evaluated in the as-melted and heat treated conditions (24 hrs at 300°C). An extremely fine microstructure was observed within the weld pools, evolving from eutectic at the outer solid-liquid boundaries to a primary Al FCC dendritic/cellular structure nearer the melt-pool centerline. We rationalized the observed microstructures through the construction of a microstructure selection map for the Al-Ce binary system, which will be used to enable future alloy design. Interestingly, the heat treated samples exhibited no microstructural coarsening.« less

  2. Analyse Pharmaceutique de la prescription des antibiotiques au service des brules et chirurgie plastique de l'Hopital Militaire d'Instruction Mohammed V, Maroc

    PubMed Central

    Benziane, H.; Karfo, R.; Siah, S.; Taoufik, J.

    2011-01-01

    Summary L'infection est longtemps restée la principale cause de mortalité chez le brûlé grave. Ce travail a pour but d'évaluer la prescription des antibiotiques dans notre Service des Brûlés et Chirurgie Plastique, au regard du dossier d'autorisation de mise sur le marché (Résumé des caractéristiques du produit). Tous les patients sous antibiothérapie, au Service des Brûlés et Chirurgie Plastique de l'Hôpital Militaire d'Instruction Mohammed V de Rabat, Maroc, durant la période janvier 2008/mai 2009, ont été inclus. Il s'agit d'une étude rétrospective qui a analysé 41 dossiers de patients. Les antibiotiques utilisés par le service appartiennent à différentes familles. Les plus utilisés sont les bêta-lactamines (65%), glycopeptides (10,5%), aminosides (9%), quinolones (7%) et colistine (4,3%), avec 4,2% pour les autres classes d'antibiotiques (métronidazole 500 mg en perfusion, fluconazole injectable 100 mg/50 ml, rifampicine 600 mg en perfusion, sulfadiazine argentique crème, acide fusidique 2% crème, etc.); 70% des prescriptions sont non documentées. La voie injectable est prépondérante (89%). En tout, 227 ordonnances nominatives d'antibiothérapie ont été analysées: la posologie et les contre-indications ont été respectées par rapport à l'autorisation de mise sur le marché. Trois cas d'interactions médicamenteuses ont été relevés (fluconazole-rifampicine, fluconazole-Saccharomyces boulardii, amikacine-vancomycine). Ce constat montre l'importance de l'analyse pharmaceutique des prescriptions des antibiotiques dans un service utilisant des antibiotiques de la réserve hospitalière, donc actifs mais très toxiques. PMID:22396670

  3. Sensor-based laser ablation for tissue specific cutting: an experimental study.

    PubMed

    Rupprecht, Stephan; Tangermann-Gerk, Katja; Wiltfang, Joerg; Neukam, Friedrich Wilhelm; Schlegel, Andreas

    2004-01-01

    The interaction of laser light and tissue causes measurable phenomenons. These phenomenons can be quantified and used to control the laser drilling within a feedback system. Ten halves of dissected minipig jaws were treated with an Er:YAG laser system controlled via a feedback system. Sensor outputs were recorded and analyzed while osteotomy was done. The relative depth of laser ablation was calculated by 3D computed tomography and evaluated histologically. The detected signals caused by the laser-tissue interaction changed their character in a dramatic way after passing the cortical bone layer. The radiological evaluation of 98 laser-ablated holes in the ten halves showed no deeper ablation beyond the cortical layer (mean values: 97.8%). Histologically, no physical damage to the alveolar nerve bundle was proved. The feedback system to control the laser drilling was working exactly for cortical ablation of the bone based on the evaluation of detected and quantified phenomenon related to the laser-tissue interaction.

  4. Transport de paires EPR dans des structures mesoscopiques

    NASA Astrophysics Data System (ADS)

    Dupont, Emilie

    Dans cette these, nous nous sommes particulierement interesses a la propagation de paires EPR1 delocalisees et localisees, et a l'influence d'un supraconducteur sur le transport de ces paires. Apres une introduction de cette etude, ainsi que du cadre scientifique qu'est l'informatique quantique dans lequel elle s'inscrit, nous allons dans le chapitre 1 faire un rappel sur le systeme constitue de deux points quantiques normaux entoures de deux fils supraconducteurs. Cela nous permettra d'introduire une methode de calcul qui sera reutilisee par la suite, et de trouver egalement le courant Josephson produit par ce systeme transforme en SQUID-dc par l'ajout d'une jonction auxiliaire. Le SQUID permet de mesurer l'etat de spin (singulet ou triplet), et peut etre forme a partir d'autres systemes que nous etudierons ensuite. Dans le chapitre 2, nous rappellerons l'etude detaillee d'un intricateur d'Andreev faite par un groupe de Bale. La matrice T, permettant d'obtenir le courant dans les cas ou les electrons sont separes spatialement ou non, sera etudiee en detail afin d'en faire usage au chapitre suivant. Le chapitre 3 est consacre a l'etude de l'influence du bruit sur le fonctionnement de l'intricateur d'Andreev. Ce bruit modifie la forme du courant jusqu'a aboutir a d'autres conditions de fonctionnement de l'intricateur. En effet, le bruit present sur les points quantiques peut perturber le transport des paires EPR par l'intermediaire des degres de liberte. Nous montrerons que, du fait de l'"intrication" entre la charge de la paire et le bruit, la paire est detruite pour des temps longs. Cependant, le resultat le plus important sera que le bruit perturbe plus le transport des paires delocalisees, qui implique une resonance de Breit-Wigner a deux particules. Le transport parasite n'implique pour sa part qu'une resonance de Breit-Wigner a une particule. Dans le chapitre 4, nous reviendrons au systeme constitue de deux points quantiques entoures de deux fils

  5. Symetries et integrabilite des equations aux differences finies

    NASA Astrophysics Data System (ADS)

    Lafortune, Stephane

    2000-09-01

    La présente thèse porte sur l'étude des symétries et des propriétés d'intégrabilité des équations aux différences finies. Dans le chapitre 1, le groupe de symétrie ponctuelle d'un système couplé à deux équations différentielles aux différences est étudié. On montre que dans certains cas, la dimension du groupe peut être infinie. Les équations peuvent décrire l'interaction de deux longues chaînes moléculaires, chacune étant composée d'atomes d'un même type. Dans le chapitre 2, une classe de théories de champs avec interaction exponentielle est introduite. L'interaction dépend de deux matrices de ``couplage'' et est suffisamment générale pour inclure toutes les théories de champs de Toda existant dans la littérature. Les symétries de Lie ponctuelles sont obtenues pour les cas où l'on a un nombre fini, infini ou semi-infini de champs. Une attention spéciale est accordée à la présence de l'invariance conforme. Dans le chapitre 3, nous procédons à la classification et à l'étude d'équations linéarisables. Nous examinons tout d'abord l'équation de Gambier continue qui contient, comme réductions, toutes les équations de deuxième ordre intégrables par linéarisation. Nous introduisons par la suite la forme discrète de cette équation et obtenons les conditions d'intégrabilité à l'aide du confinement des singularités. Nous étudions aussi les différentes réductions du cas discret. De plus, nous obtenons des transformations de Schlesinger pour les équations de Gambier discrète et continue. Dans la dernière partie du chapitre, nous étudions une famille d'équations discrètes du deuxième ordre incluant des équations résolubles par linéarisation. Plusieurs cas intégrables sont obtenus. Dans le cas discret, l'étude de l'intégrabilité est faite à l'aide du confinement des singularités. Dans le chapitre 4, nous étudions un autre critère d'intégrabilité: l'entropie algébrique. Nous montrons que les r

  6. Elaboration de revetements nanocomposites avec des proprietes superhydrophobes, semi-conductrices et photocatalytiques

    NASA Astrophysics Data System (ADS)

    Madidi, Fatima Zahra

    Les lignes aeriennes de transport et de distribution de l'energie electrique sont souvent exposees a diverses contraintes. Parmi celles-ci, la pollution des isolateurs constitue l'un des facteurs de premiere importance dans la fiabilite du transport d'energie. En effet, la presence de pollution sur les isolateurs lorsqu'elle est humidifiee entraine la diminution de leur performance electrique en favorisant l'apparition d'arcs de contournement. De telles pannes peuvent parfois causer des impacts socioeconomiques importants. Par ailleurs, le developpement de nouveaux revetements pour ces isolateurs peut s'averer un moyen efficace pour les proteger contre l'apparition de l'arc de contournement. Les revetements superhydrophobes ont fait l'objet de nombreuses etudes au cours de ces dernieres annees. Ces surfaces sont preparees en combinant une rugosite nano-microstructuree avec une faible energie de surface. En outre, de telles surfaces ont de nombreuses applications si elles sont durables et n'ont pas d'effets nocifs sur l'environnement. L'objectif principal de la presente etude vise d'abord l'elaboration de revetements superhydrophobes, puis l'etude de leur duree de vie, leurs proprietes dielectriques et photocatalytiques. Une grande variete de materiaux a faible energie de surface peuvent etre utilises pour le developpement de ces revetements. Dans cette recherche, le caoutchouc de silicone (CS) est employe car il presente de nombreuses proprietes, notamment une forte hydrophobie, une resistance aux rayonnements ultraviolets, et une bonne tenue au feu sans degagement de produits toxiques. Toutefois, le point faible de ces materiaux est la degradation de leurs proprietes hydrophobes. Afin d'ameliorer certaines proprietes du caoutchouc de silicone, des nanoparticules seront additionnees au polymere de base. La technique d'elaboration des revetements consiste a ajouter des nanoparticules de dioxyde de titane (TiO2) au polymere de base, par des methodes ayant un

  7. Numerical evaluation of the laser-pulse modification modes of the metal surface layer in the presence of a surface-active component in the melt

    NASA Astrophysics Data System (ADS)

    Popov, V. N.; Cherepanov, A. N.

    2017-09-01

    Numerical evaluation of the laser-pulse modification of a metal layer with refractory nano-size particles was done. The modes of the laser-pulse action promoting creation of the flows for homogeneous distribution of modifying particles in the melt were determined for various amounts of the surface-active admixture in the metal.

  8. Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1995-01-01

    Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.

  9. Modelisation des emissions de particules microniques et nanometriques en usinage

    NASA Astrophysics Data System (ADS)

    Khettabi, Riad

    La mise en forme des pieces par usinage emet des particules, de tailles microscopiques et nanometriques, qui peuvent etre dangereuses pour la sante. Le but de ce travail est d'etudier les emissions de ces particules pour fins de prevention et reduction a la source. L'approche retenue est experimentale et theorique, aux deux echelles microscopique et macroscopique. Le travail commence par des essais permettant de determiner les influences du materiau, de l'outil et des parametres d'usinage sur les emissions de particules. E nsuite un nouveau parametre caracterisant les emissions, nomme Dust unit , est developpe et un modele predictif est propose. Ce modele est base sur une nouvelle theorie hybride qui integre les approches energetiques, tribologiques et deformation plastique, et inclut la geometrie de l'outil, les proprietes du materiau, les conditions de coupe et la segmentation des copeaux. Il ete valide au tournage sur quatre materiaux: A16061-T6, AISI1018, AISI4140 et fonte grise.

  10. Evaluation of diode laser and stannous fluoride in the treatment of root sensitivity after access flap surgery: Randomized controlled clinical trial.

    PubMed

    Raut, Chetan Purushottam; Sethi, Kunal Sunder; Kohale, Bhagyashree; Mamajiwala, Alefiya; Warang, Ayushya

    2018-01-01

    Postsurgical root sensitivity has always been an enigma to the periodontists. There is a plethora of evidence suggesting the presence of root sensitivity following periodontal flap surgical procedures. Thus, the aim of the present study was to compare and evaluate the effect of low-power diode lasers with and without topical application of stannous fluoride (SnF 2 ) gel in the treatment of root sensitivity and also evaluate whether laser creates any placebo effect in the control group or not. Thirty patients participated in this study and 99 teeth were included. Root sensitivity was assessed for all groups with a Verbal Rating Scale (VRS). For each patient, the teeth were randomized into three groups. In the test Group I, sensitive teeth were treated with SnF 2 and diode laser. In the test Group II, sensitive teeth were irradiated with laser only. In the control group, no treatment was performed. The mean ± standard deviation (SD) score for VRS and Visual Analog Scale at baseline was not statistically significant ( P > 0.05) between the three groups. After 15 min, statistical significant difference was seen in test Group I and test Group II, although no difference was found in the control group. At 15 th day and 30 th day, the mean ± SD scores were statistically significant ( P < 0.05). Within the limitations of the study, it can be concluded that diode lasers alone and in combination with 0.4% SnF 2 was effective in the treatment of root sensitivity after access flap surgery.

  11. Excimer lasers

    NASA Technical Reports Server (NTRS)

    Palmer, A. J.; Hess, L. D.; Stephens, R. R.; Pepper, D. M.

    1977-01-01

    The results of a two-year investigation into the possibility of developing continuous wave excimer lasers are reported. The program included the evaluation and selection of candidate molecular systems and discharge pumping techniques. The K Ar/K2 excimer dimer molecules and the xenon fluoride excimer molecule were selected for study; each used a transverse and capillary discharges pumping technique. Experimental and theoretical studies of each of the two discharge techniques applied to each of the two molecular systems are reported. Discharge stability and fluorine consumption were found to be the principle impediments to extending the XeF excimer laser into the continuous wave regime. Potassium vapor handling problems were the principal difficulty in achieving laser action on the K Ar/K2 system. Of the four molecular systems and pumping techniques explored, the capillary discharge pumped K Ar/K2 system appears to be the most likely candidate for demonstrating continuous wave excimer laser action primarily because of its predicted lower pumping threshold and a demonstrated discharge stability advantage.

  12. Evaluating the use of high speed laser line sensors for improved rideability measurement.

    DOT National Transportation Integrated Search

    2016-09-01

    This research project compared rideability readings and repeatability for both point laser and line laser systems on the high-speed profiler. Both systems were Dynatest 5051 Mark III Road Surface Profilers, one equipped with single point lasers and t...

  13. Studies of new media radiation induced laser

    NASA Technical Reports Server (NTRS)

    Han, K. S.; Shiu, Y. J.; Raju, S. R.; Hwang, I. H.; Tabibi, B.

    1984-01-01

    Various lasants were investigated especially, 2-iodohepafluoropropane (i-C3F7I) for the direct solar pumped lasers. Optical pumping of iodine laser was achieved using a small flashlamp. Using i-C3F7I as a laser gain medium, threshold inversion density, small signal gain, and laser performance at the elevated temperature were measured. The experimental results and analysis are presented. The iodine laser kinetics of the C3F7I and IBr system were numerically simulated. The concept of a direct solar-pumped laser amplifier using (i-C3F7I) as the laser material was evaluated and several kinetic coefficients for i-C3F7I laser system were reexamined. The results are discussed.

  14. Temperature evaluation of dental implant surface irradiated with high-power diode laser.

    PubMed

    Rios, F G; Viana, E R; Ribeiro, G M; González, J C; Abelenda, A; Peruzzo, D C

    2016-09-01

    The prevalence of peri-implantitis and the absence of a standard approach for decontamination of the dental implant surface have led to searches for effective therapies. Since the source of diode lasers is portable, has reduced cost, and does not cause damage to the titanium surface of the implant, high-power diode lasers have been used for this purpose. The effect of laser irradiation on the implants is the elevation of the temperature surface. If this elevation exceeds 47 °C, the bone tissue is irreversibly damaged, so for a safety therapy, the laser parameters should be controlled. In this study, a diode laser of GaAsAl was used to irradiate titanium dental implants, for powers 1.32 to 2.64 W (real) or 2.00 to 4.00 W (nominal), in continuous/pulsed mode DC/AC, with exposure time of 5/10 s, with/without air flow for cooling. The elevation of the temperature was monitored in real time in two positions: cervical and apical. The best results for decontamination using a 968-nm diode laser were obtained for a power of 1.65 and 1.98 W (real) for 10 s, in DC or AC mode, with an air flow of 2.5 l/min. In our perspective in this article, we determine a suggested approach for decontamination of the dental implant surface using a 968-nm diode laser.

  15. Clinical and histological evaluation of laser therapy in the treatment of oral mucositis in an animal model

    NASA Astrophysics Data System (ADS)

    Vitória, L. A.; Machado, R. M.; Oliveira, C. R. B.; Rodriguez, T. T.; Cangussu, M. C. T.; Mathias, C. C.; Ramalho, L. M. P.

    2018-04-01

    Oral mucositis (MO) is considered to be the most severe stomatologic complication associated with antineoplastic treatment, which may lead to its interruption. Several current clinical protocols have aproven the benefits of Laser Photobiomodulation (LP) in the prevention and control of MO, due to its analgesic and anti-inflammatory effects and its stimulation of mesenchymal cells proliferation. The objective of this study was to evaluate the action of laser in initial events of chemo-induced MO. Eight Hamsters were divided into 2 groups (G): GI positive control (induction of MO) and GII Laser (induction of MO + Laser therapy). MO was induced by two injections of 5-Fluorouracil followed by grooves in the mucosa of the cheek pouch. The PL (Diode Laser of Gallium and Aluminum Arsenide, λ660nm, 40mW, 2,4J/cm2 ) was performed on day 0 of the experiment and every 48 hours until day 6. On day 7 the mucosa was photographed for clinical analysis according to Lima et al., 2005 and the animals were killed, for bag removal and histological processing for Hematoxylin and Eosin (H / E) staining. After statistical analysis (Fischer's Exact) with a significance level 0.5%, it was concluded that the LP, according to the adopted protocol, was able to prevent MO, and most hamsters showed no visible clinical changes in the cheek pouch. Histologically, it was observed that LP reduced angiogenesis and recruitment of inflammatory cells in G2. According to the results obtained LP was effective in preventing and reducing the severity of oral mucositis.

  16. Evaluation of the clinical and antimicrobial effects of the Er:YAG laser or topical gaseous ozone as adjuncts to initial periodontal therapy.

    PubMed

    Yılmaz, Selçuk; Algan, Serdar; Gursoy, Hare; Noyan, Ulku; Kuru, Bahar Eren; Kadir, Tanju

    2013-06-01

    The aim of this study was to evaluate the clinical and microbiological results of treatment with the Er:YAG laser and topical gaseous ozone application as adjuncts to initial periodontal therapy in chronic periodontitis (CP) patients. Although many studies have evaluated the effectiveness of the Er:YAG laser as an adjunct to initial periodontal therapy, few studies have focused on the use of gaseous ozone as an adjunct. Thirty patients with CP were randomly divided into three parallel groups, each composed of 10 individuals with at least four teeth having at least one approximal site with a probing depth (PD) of ≥5 mm and a sulcus bleeding index (SBI) ≥2 in each quadrant. Groups of patients received: (1) Scaling and root planing (SRP)+Er:YAG laser; (2) SRP+topical gaseous ozone; or (3) SRP alone. The microbiological and clinical parameters were monitored at day 0 and day 90. At the end of the observation period, statistically significant improvements in clinical parameters were observed within each group. Parallel to the clinical changes, all treatments reduced the number of total bacteria and the proportion of obligately anaerobic microorganisms. Although intergroup comparisons of microbiological parameters showed no significant differences, clinical findings, including attachment gain and PD reduction, were found to be statistically significant in favor of the SRP+Er:YAG laser group. Although statistically nonsignificant, the fact that the obligate anaerobic change was mostly observed in the SRP+Er:YAG laser group, and a similar decrease was noted in the SRP+topical gaseous ozone group, shows that ozone has an antimicrobial effect equivalent to that of the Er:YAG laser.

  17. La prévention des infections par le virus respiratoire syncytial

    PubMed Central

    Robinson, JL

    2011-01-01

    RÉSUMÉ L’infection par le virus respiratoire syncytial (VRS) est la principale cause d’infections des voies respiratoires inférieures chez les jeunes enfants. Le palivizumab, un anticorps monoclonal anti-VRS, réduit le taux d’hospitalisation des enfants à haut risque mais est très coûteux. Le présent document de principes remplace les trois précédents documents de principes de la Société canadienne de pédiatrie sur le sujet et est mis à jour principalement pour traiter des récentes modifications aux lignes directrices de l’American Academy of Pediatrics dans le contexte canadien. Il contient une analyse des publications ainsi que des recommandations au sujet de l’utilisation du palivizumab chez les enfants à haut risque

  18. Holmium:YAG surgical lasers.

    PubMed

    1995-03-01

    preferable for small-joint and some head-and-neck surgeries or for office use, and high-power units are more suitable for use in major surgery, such as gastrointestinal surgery or surgery in large joints. This evaluation includes two units at both ends of the Ho:YAG power spectrum--one 10 W and one 60 W--and thus provides a guide to evaluating other Ho:YAG lasers that are currently available or that will be entering the market.(ABSTRACT TRUNCATED AT 400 WORDS)

  19. Theoretical evaluation of a continues-wave Ho3+:BaY2F8 laser with mid-infrared emission

    NASA Astrophysics Data System (ADS)

    Rong, Kepeng; Cai, He; An, Guofei; Han, Juhong; Yu, Hang; Wang, Shunyan; Yu, Qiang; Wu, Peng; Zhang, Wei; Wang, Hongyuan; Wang, You

    2018-01-01

    In this paper, we build a theoretical model to study a continues-wave (CW) Ho3+:BaY2F8 laser by considering both energy transfer up-conversion (ETU) and cross relaxation (CR) processes. The influences of the pump power, reflectance of an output coupler (OC), and crystal length on the output features are systematically analyzed for an end-pumped configuration, respectively. We also investigate how the processes of ETU and CR in the energy-level system affect the output of a Ho3+:BaY2F8 laser by use of the kinetic evaluation. The simulation results show that the optical-to-optical efficiency can be promoted by adjusting the parameters such as the reflectance of an output coupler, crystal length, and pump power. It has been theoretically demonstrated that the threshold of a Ho3+:BaY2F8 laser is very high for the lasing operation in a CW mode.

  20. Lasers in digestive endoscopy

    NASA Astrophysics Data System (ADS)

    Brunetaud, Jean Marc; Maunoury, Vincent; Cochelard, Dominique

    1997-01-01

    Lasers were introduced in digestive endoscopy to stop active gastroduodenal hemorrhages. Their use spread progressively to the treatment of chronic hemorrhages from vascular malformations and sessile tumors. Laser face competition from other endoscopic techniques such as electrocoagulation, injection techniques, dilation, stents, and brachytherapy. Many series have reported the efficacy of lasers in digestive endoscopy used for their thermal or photochemical effects. However, they were gradually abandoned for the treatment of hemorrhages because of competition from nonlaser techniques. Lasers are still used for ablation of sessile tumors, but their true impact is difficult to evaluate. Modern methods of technology assessment did not allow gastroenterologists to clearly define the place of lasers among surgery, radio-chemotherapy, and other endoscopic techniques, and data on the daily use of lasers are not available. Therefore, the conclusion can only be subjective. The best current application of thermal lasers appears to be in the treatment of rectosigmoid villous adenomas in elderly patients. Small superficial rectal cancers may also become a good subject due to the impact of endoscopic ultrasonography. Early lesions with multifocal or diffuse disease such as early esophageal cancers could be the most promising subject of application for photodynamic therapy in the future.

  1. Inhibition of DES-induced DNA adducts by diallyl sulfide: implications in liver cancer prevention.

    PubMed

    Green, Mario; Thomas, Ronald; Gued, Lisa; Sadrud-Din, Sakeenah

    2003-01-01

    Diethylstilbesterol (DES) is known to cause cancer in humans and animals. Diallyl sulfide (DAS), a component of garlic, has been shown to prevent various types of cancer, presumably via metabolic modulation. Previously, we have demonstrated that DAS prevents the oxidation and reduction of DES in vitro. We hypothesize that DAS will inhibit the metabolism of DES in vivo thus preventing the formation of DES-induced DNA adducts. To test this hypothesis, five groups of five male Sprague-Dawley rats were treated as follows: the control received 0.5 ml of corn oil daily for four days. The second group received 50 mg/kg DAS daily for four days. The third group received 50 mg/kg DAS daily for four days followed by 150 mg/kg DES on day five. The fourth group received 400 mg/kg DAS on day five followed by 150 mg/kg DES. The fifth group received 150 mg/kg DES on day five. All of the rats were sacrificed on day five, 4 h after DES treatment. DNA was isolated from the liver and analyzed by 32P-post-labeling for DNA adducts. The in vitro study was performed utilizing four reactions described as follows: the control reaction contained 200 microg DNA, microsomes (346 microg protein/ml), and 10 mM DES; no oxidation co-factor (cumen hydroperoxide) was added. The second reaction, a complete oxidation system, contained 200 microg DNA, microsomes (346 microg protein/ml), 30 mM cumen hydroperoxide, and 10 mM DES. The third reaction contained 200 microg DNA, microsomes (346 microg protein/ml), 30 mM cumen hydroperoxide, 50 mM DAS, and 10 mM DES. The fourth reaction contained 200 microg DNA, microsomes (346 microg protein/ml), 30 mM cumen hydroperoxide, 100 mM DAS, and 10 mM DES. All of the in vitro reactions were buffered with 100 mM KPO4 pH 7.4 and incubated for 30 min at 37 degrees C. DNA was extracted and analyzed by 32P-post-labeling. We found that DAS inhibited the formation of DES-induced DNA adducts in a dose-dependent fashion. We have shown that DES-induced DNA adducts were

  2. Laser marking as environment technology

    NASA Astrophysics Data System (ADS)

    Sobotova, Lydia; Badida, Miroslav

    2017-11-01

    The contribution deals with the laser marking as one of the progressive and environment friendly technologies with utilisation in many branches of industry. Engraving and other types of laser marking of different types of materials are very actual technologies these days. Laser marking decreases the waste creation in comparison with the other classical marking technologies, which use paintings or created chips. In this experimental investigation the laser marking surface texturing of material AL99,7 according to STN 42 4003:1993-08 (STN EN 573) has been conducted. The laser marking machine TruMark 6020 and software TruTops Mark were used. Laser surface texturing after laser marking has been realised under different combinations of process parameters: pulse frequency, pulse energy and laser beam scanning speed. The morphological characterization of engraving or annealing surfaces has been performed using scanning electron microscopy (SEM) technique. The evaluation of roughness of engraved surfaces has been realized according to STN EN ISO 4287 by using Surftest SJ 301. The aim of the contribution was to show how different laser parameters affect the surface texture and colour change of metallic materials while creating minimal waste.

  3. NATO Human Resources (Manpower) Management (Gestion des ressources humaines (effectifs) de l’OTAN)

    DTIC Science & Technology

    2012-02-01

    performances , la gestion des récompenses et du salaire, et la motivation du personnel. En conséquence, il faut que la gestion des ressources humaines...importance au fil du temps. Les ressources humaines, chargées à l’origine de l’embauche, du licenciement, de la paie et de la gestion des ...les effets des systèmes d’évaluation des performances ;

  4. Evaluation of laser therapy and alpha-lipoic acid for the treatment of burning mouth syndrome: a randomized clinical trial.

    PubMed

    Barbosa, Natália Guimarães; Gonzaga, Amanda Katarinny Goes; de Sena Fernandes, Luzia Leiros; da Fonseca, Aldilane Gonçalves; Queiroz, Salomão Israel Monteiro Lourenço; Lemos, Telma Maria Araújo Moura; da Silveira, Éricka Janine Dantas; de Medeiros, Ana Miryam Costa

    2018-03-03

    The aim of this study was to evaluate the efficacy of low-level laser therapy (LLLT) and alpha-lipoic acid (ALA) in the treatment of burning mouth syndrome (BMS) and secondary oral burning (SOB) by unstimulated sialometry, symptom assessment, and measurement of salivary TNF-α levels. Forty-four patients were randomized into four treatment groups: BMS/laser (n = 10), BMS/ALA (n = 5), SOB/laser (n = 15), and SOB/ALA (n = 14). The control group consisted of eight healthy female subjects. Unstimulated salivary flow was measured before and after treatment, and the collected saliva was stored at - 20 °C for the analysis of TNF-α. Symptoms were evaluated before and after treatment using a pain visual analog scale. Most patients were women (81.8%) during menopause (72.2%). LLLT and ALA were efficient in increasing salivary flow only in BMS but provided symptom relief in both conditions. TNF-α levels did not differ between patients with BMS and SOB or between those patients and the control group. No differences were observed in posttreatment TNF-α levels in either condition. The results of this study suggest that LLLT and ALA are efficient therapies in reducing burning mouth symptoms, with LLLT being more efficient than ALA.

  5. Excimer laser ablation of the cornea

    NASA Astrophysics Data System (ADS)

    Pettit, George H.; Ediger, Marwood N.; Weiblinger, Richard P.

    1995-03-01

    Pulsed ultraviolet laser ablation is being extensively investigated clinically to reshape the optical surface of the eye and correct vision defects. Current knowledge of the laser/tissue interaction and the present state of the clinical evaluation are reviewed. In addition, the principal findings of internal Food and Drug Administration research are described in some detail, including a risk assessment of the laser-induced-fluorescence and measurement of the nonlinear optical properties of cornea during the intense UV irradiation. Finally, a survey is presented of the alternative laser technologies being explored for this ophthalmic application.

  6. Des Moines metropolitan area ITS strategic plan : executive summary

    DOT National Transportation Integrated Search

    1997-12-01

    This is an executive summary of a strategic plan for deploying Intelligent Transportation Systems (ITS) technology in the Des Moines metropolitan area. The plan was developed as part of the Des Moines ITS Early Deployment Study (EDS). ITS is the use ...

  7. La santé des Premières nations, des Inuits et des Métis: les facteurs que doivent envisager les leaders en santé canadiens dans la foulée du rapport de la Commission de vérité et réconciliation du Canada.

    PubMed

    McNally, Mary; Martin, Debbie

    2017-03-01

    Les peuples des Premières nations, inuits et métis qui habitent au Canada sont aux prises avec de profondes disparités en matière de santé par rapport aux Canadiens non autochtones, et ce, dans presque toutes les mesures liées à la santé et au bien-être. Pour faire progresser les services de santé auprès des peuples autochtones, il faut passer à l'action dans tous les ordres de prestation des soins et des politiques en santé. Il est donc essentiel que les leaders et les prestataires des établissements, des systèmes et des installations de santé du Canada comprennent et prennent en main les déterminants de la santé propres aux peuples autochtones, y compris l'héritage du colonialisme et le racisme ancien et actuel. La Commission de vérité et réconciliation du Canada est le point de départ pour réagir de manière positive aux injustices.

  8. Evaluation of agreement among dermatologists in the assessment of the color of port wine stains and their clearance after treatment with the flashlamp-pumped dye laser.

    PubMed

    Pérez, B; Abraira, V; Núñez, M; Boixeda, P; Perez Corral, F; Ledo, A

    1997-01-01

    Color classification and its subjective clearance evaluation in response to treatment are essential in the management of patients with port wine stains (PWS). But color perception by physicians is not an objective measurement so that it can change among observers. Agreement among physicians is essential for the reliability of the color classification and the clinical assessment of the response to laser treatment. The purpose of our study was to determine the reliability of the clinical color classification of port wine stains and of their color change or clearance in response to laser treatment. The study was not designed to evaluate the outcome of laser treatment in PWS or the factors that could predict the final response. We used the kappa index to evaluate the proportion of agreement in color and clearance perception among dermatologists. Six dermatologists classified the initial color of PWS in 80 patients. Three of them also assessed the amount of clearance achieved after treatment with the flashlamp-pumped dye laser. These three dermatologists were usually dedicated to treat patients with PWS, while the other three were not. The kappa index showed a substantial agreement in both cases. No difference in the initial color perception was observed between the group of dermatologists specialized in PWS and the other three dermatologists. These results favor the reliability of the clinical method in the assessment of PWS before and after laser treatment. So, although subjective, color perception by physicians can be used in the study of laser treatment outcome in PWS and its related factors, and the results of different authors can be compared.

  9. The efficacy and safety of subcision using CO2 gas combined with fractional laser for acne scars: Clinical and microscopic evaluation.

    PubMed

    Lee, Sang Jun; Suh, Dong Hye; Chang, Ka Yeon; Kim, Hyun Joo; Kim, Tae In; Jeong, Ki-Heon; Shin, Min Kyung; Song, Kye Yong

    2016-11-01

    Various modalities have been used to treat acne scars. CO 2 fractional laser is an effective and commonly used treatment. CO 2 gas injection into the dermis by needle with high pressure can cause fibrotic collagen breakage, producing the effects of subcision. CO 2 also stimulates collagen synthesis by increasing neovascularization and releasing oxygen. This study evaluated the efficacy and the safety of the combined treatment with CO 2 gas subcision and CO 2 fractional laser for acne scars. Fourteen patients with acne scars were treated with three sessions of CO 2 gas subcision at 2-week intervals and two sessions of fractional laser at 4-week interval. The clinical improvement was assessed using a 4-point scale. For histologic analysis, punch biopsy was performed before and after treatment in 10 patients. All patients experienced clinical improvements. Excellent, marked, moderate, and mild response was achieved in 1 (7%), 8 (57%), 4 (29%), and 1 patient (7%), respectively. Histologic evaluation of the biopsy specimens showed increased dermal collagen with dermal thickening and elastic fiber straightening in the reticular dermis after the treatment. The combination therapy with CO 2 gas subcision and fractional laser was satisfactory and safe for treating acne scars. Abbreviation and acronym: CO 2 : Carbon dioxide GAS: Global assessment scale H&E: hematoxylin and eosin; SD: standard deviation.

  10. Laser Ignition Technology for Bi-Propellant Rocket Engine Applications

    NASA Technical Reports Server (NTRS)

    Thomas, Matthew E.; Bossard, John A.; Early, Jim; Trinh, Huu; Dennis, Jay; Turner, James (Technical Monitor)

    2001-01-01

    The fiber optically coupled laser ignition approach summarized is under consideration for use in igniting bi-propellant rocket thrust chambers. This laser ignition approach is based on a novel dual pulse format capable of effectively increasing laser generated plasma life times up to 1000 % over conventional laser ignition methods. In the dual-pulse format tinder consideration here an initial laser pulse is used to generate a small plasma kernel. A second laser pulse that effectively irradiates the plasma kernel follows this pulse. Energy transfer into the kernel is much more efficient because of its absorption characteristics thereby allowing the kernel to develop into a much more effective ignition source for subsequent combustion processes. In this research effort both single and dual-pulse formats were evaluated in a small testbed rocket thrust chamber. The rocket chamber was designed to evaluate several bipropellant combinations. Optical access to the chamber was provided through small sapphire windows. Test results from gaseous oxygen (GOx) and RP-1 propellants are presented here. Several variables were evaluated during the test program, including spark location, pulse timing, and relative pulse energy. These variables were evaluated in an effort to identify the conditions in which laser ignition of bi-propellants is feasible. Preliminary results and analysis indicate that this laser ignition approach may provide superior ignition performance relative to squib and torch igniters, while simultaneously eliminating some of the logistical issues associated with these systems. Further research focused on enhancing the system robustness, multiplexing, and window durability/cleaning and fiber optic enhancements is in progress.

  11. Untersuchung des Funktionsumfangs und der fachlichen Grundlagen des LAMBDA Tools (Examination of the functional scope and the technical basics of the LAMBDA- Tools)

    DTIC Science & Technology

    2017-01-01

    Copyrighted. (1 and 20) ABSTRACT (Maximum 200 words) The founding years of Operations Research (OR) are the years just before and during the Second World... Research ............................................................................................. 1 1.2 Teilgebiete des Operations Research ...2 1.3 Madelle des Operations Research

  12. Grundlagen des Tissue Engineering

    NASA Astrophysics Data System (ADS)

    Mayer, Jörg; Blum, Janaki; Wintermantel, Erich

    Die Organtransplantation stellt eine verbreitete Therapie dar, um bei krankheitsoder unfallbedingter Schädigung eines Organs die Gesamtheit seiner Funktionen wieder herzustellen, indem es durch ein Spenderorgan ersetzt wird. Organtransplantationen werden für die Leber, die Niere, die Lunge, das Herz oder bei schweren grossflächigen Verbrennungen der Haut vorgenommen. Der grosse apparative, personelle und logistische Aufwand und die Risiken der Transplantationschirurgie (Abstossungsreaktionen) sowie die mangelnde Verfügbarkeit von immunologisch kompatiblen Spenderorganen führen jedoch dazu, dass der Bedarf an Organtransplantaten nur zu einem sehr geringen Teil gedeckt werden kann. Sind Spenderorgane nicht verfügbar, können in einzelnen Fällen lebenswichtige Teilfunktionen, wie beispielsweise die Filtrationsfunktion der Niere durch die Blutreinigung mittels Dialyse ersetzt oder, bei mangelnder Funktion der Bauchspeicheldrüse (Diabetes), durch die Verabreichung von Insulin ein normaler Zustand des Gesamtorganismus auch über Jahre hinweg erhalten werden. Bei der notwendigen lebenslangen Anwendung apparativer oder medikamentöser Therapie können für den Patienten jedoch häufig schwerwiegende, möglicherweise lebensverkürzende Nebenwirkungen entstehen. Daher werden in der Forschung Alternativen gesucht, um die Funktionen des ausgefallenen Organs durch die Implantation von Zellen oder in vitro gezüchteten Geweben möglichst umfassend wieder herzustellen. Dies erfordert biologisch aktive Implantate, welche die für den Stoffwechsel des Organs wichtigen Zellen enthalten und einen organtypischen Stoffwechsel entfalten.

  13. Space qualified Nd:YAG laser (phase 1 - design)

    NASA Technical Reports Server (NTRS)

    Foster, J. D.; Kirk, R. F.

    1971-01-01

    Results of a design study and preliminary design of a space qualified Nd:YAG laser are presented. A theoretical model of the laser was developed to allow the evaluation of the effects of various parameters on its performance. Various pump lamps were evaluated and sum pumping was considered. Cooling requirements were examined and cooling methods such as radiation, cryogenic and conductive were analysed. Power outputs and efficiences of various configurations and the pump and laser lifetime are discussed. Also considered were modulation and modulating methods.

  14. Biocompatibility enhancement of rare earth magnesium alloy by laser surface processing

    NASA Astrophysics Data System (ADS)

    Nie, Shilin; Wang, Yuqing; Liu, Haifeng; Guan, Yingchun

    2018-01-01

    Although magnesium and magnesium alloys are considered biocompatible and biodegradable, insufficient biocompatibility in body fluid environment is still the major drawback of magnesium alloys for their successful applications as biodegradable orthopaedic implants. In this work, magnesium alloy surface with both enhanced corrosion resistance and better cell adhesion property was directly fabricated by laser surface processing. Laser surface melting was used to improve corrosion resistance of Mg-6Gd-0.6Ca alloy. After laser surface melting, laser surface texturing was utilized on melted surface for better cell adhesion property. The corrosion resistance of laser-treated and as-received samples were evaluated using electrochemical technique. The effect of laser surface treatment on phase and microstructure evolution was evaluated using scanning electron microscopy, optical microscopy and X-ray diffraction. This work investigated the effect of laser treatment on cell distribution across the surface of magnesium alloy substrates. Osteoblast was cultured on the laser-treated surface and as-received surface. Cell morphology was observed with a scanning electron microscopy, and cell viability was evaluated by optical density measurement.

  15. Evaluation of the effect of fractional CO2 laser on histopathological picture and TGF-β1 expression in hypertrophic scar.

    PubMed

    Makboul, Mohamed; Makboul, Rania; Abdelhafez, Assem Hk; Hassan, Safaa Said; Youssif, Sherif M

    2014-09-01

    Hypertrophic scar is a form of abnormal wound healing process in which tissue repair regulating mechanism is disrupted. Transforming growth factor β1 has a particular importance in the fibrotic scarring response. Treatment of hypertrophic scar included many chemical, physical, and surgical options. Fractional CO2 laser devices have gained acceptance as a way for managing hypertrophic scar. Aims of this study are: (a) to determine the clinical and histopathological effects of fractional CO2 laser on hypertrophic scar, (b) to evaluate the expression pattern of transforming growth factor-β1 (TGF-β1) as an important fibrogenic factor before and 6 months after fractional CO2 laser treatment. Forty patients of hypertrophic scar were selected, each patient was treated by four sessions with 1 month apart with fractional CO2 laser. Vancouver Scar Scale (VSS) was used to assess the patients before and after laser treatment. Skin biopsy was taken from eight cases before and 3 months after four fractional CO2 laser sessions and four normal skin control biopsies. All were assessed by hematoxylin-eosin (H&E), Masson's trichrome, Van Gieson and immunohistochemical (IHC) staining with TGF-β1. The epidermal thickness was assessed before and after treatment by image analyzing system software. There was statistically significant difference in VSS before and after fractional CO2 laser (P > 0.001). The epidermal thickness showed significant increase after laser treatment (P > 0.001), and there was also thinning in stratum corneum and replacement of the irregular collagen bands with organized new collagen fibrils as demonstrated by H&E and the other special stains. The study also showed significant decrease in TGF-β1 expression after laser therapy (P = 0.008). Fractional CO2 laser could be considered as a good way for hypertrophic scar management. It normalizes dermal collagen as imaged by histopathological picture and the change in TGF-β1 expression. © 2014 Wiley

  16. Base-Level Management of Laser Radiation Protection Program

    DTIC Science & Technology

    1992-02-01

    safety eyewear . special considerations for medical lasers and optical fibers, and summary evaluations of common Air Force laser systems... optical density of 2. Laser safety eyewear should have the optical density clearly marked for ail wavelengths for which the eyewear provides protection. c...density of protective eyewear . The optical density required for laser safety eyewear is dependent on the irradiance or radiant exposure-of the

  17. Disability Evaluation Systems Analysis and Research Annual Report 2014

    DTIC Science & Technology

    2015-03-30

    DES database should include one or more Medical Evaluation Board (MEB) diagnoses in the electronic disability record, in the form of text and ICD-9...Washington, DC: 2008. Available at http://www.pdhealth.mil/ hss /des.asp Accessed August 13, 2010. 2. Peck CA. The U.S. Army Physical Disability System

  18. Investigation into the Use of the Concept Laser QM System as an In-Situ Research and Evaluation Tool

    NASA Technical Reports Server (NTRS)

    Bagg, Stacey

    2014-01-01

    The NASA Marshall Space Flight Center (MSFC) is using a Concept Laser Fusing (Cusing) M2 powder bed additive manufacturing system for the build of space flight prototypes and hardware. NASA MSFC is collecting and analyzing data from the M2 QM Meltpool and QM Coating systems for builds. This data is intended to aide in understanding of the powder-bed additive manufacturing process, and in the development of a thermal model for the process. The QM systems are marketed by Concept Laser GmbH as in-situ quality management modules. The QM Meltpool system uses both a high-speed near-IR camera and a photodiode to monitor the melt pool generated by the laser. The software determines from the camera images the size of the melt pool. The camera also measures the integrated intensity of the IR radiation, and the photodiode gives an intensity value based on the brightness of the melt pool. The QM coating system uses a high resolution optical camera to image the surface after each layer has been formed. The objective of this investigation was to determine the adequacy of the QM Meltpool system as a research instrument for in-situ measurement of melt pool size and temperature and its applicability to NASA's objectives in (1) Developing a process thermal model and (2) Quantifying feedback measurements with the intent of meeting quality requirements or specifications. Note that Concept Laser markets the system only as capable of giving an indication of changes between builds, not as an in-situ research and evaluation tool. A secondary objective of the investigation is to determine the adequacy of the QM Coating system as an in-situ layer-wise geometry and layer quality evaluation tool.

  19. Evaluation of the potential of laser-induced breakdown spectroscopy for detection of trace element in liquid.

    PubMed

    Yueh, Fang-Yu; Sharma, Ramesh C; Singh, Jagdish P; Zhang, Hansheng; Spencer, William A

    2002-11-01

    The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.

  20. La réfrigération des grandes machines supraconductrices

    NASA Astrophysics Data System (ADS)

    Gistau, Guy

    1991-02-01

    The large scale superconducting devices which are now in operation for deviation of heavy particles, acceleration of light particles or plasma confinement need very large powers of refrigeration. After a short survewing of the different functions of refrigerators and the special requirements for large units, the paper describes some existing or envisaged cooling systems which have an equivalent cooling power in the range of 5 kW at 4.5 K. Les grands appareils de physique utilisant les supraconducteurs demandent des puissances cryogéniques de plus en plus importantes. Après un examen des fonctions élémentaires assurées par un réfrigérateur liées au cahier des charges spécifique à chaque utilisation, les spécificités des grosses unités de réfrigération (fiabilité, efficacité, flexibilité, automatisme) sont mises en évidence. Les solutions proposées dans plusieurs grands projets nécessitant des puissances froides supérieures à 5 kW à 4,5 K sont discutées.

  1. The use of laser in hysteroscopic surgery.

    PubMed

    Nappi, Luigi; Sorrentino, Felice; Angioni, Stefano; Pontis, Alessandro; Greco, Pantaleo

    2016-12-01

    The term laser, an acronym for light amplification by stimulated emission of radiation, covers a wide range of devices. Lasers are commonly described by the emitted wavelength that covers the entire light spectrum from infrared to ultraviolet and the active lasing medium. Currently, over forty different types of lasers have found application in medicine. Moreover, advances made by gynecologists in the field of operative hysteroscopy have developed a very great interest in the use of surgical lasers. Technical improvements in hysteroscopes and lasers have led several gynecologists to evaluate their use in the surgical treatment of intrauterine pathologies. This narrative review concerns the most common used lasers in hysteroscopic surgery with particular attention to the latest promising results of the laser technology.

  2. Soins primaires aux adultes ayant des déficiences intellectuelles et développementales

    PubMed Central

    Sullivan, William F.; Diepstra, Heidi; Heng, John; Ally, Shara; Bradley, Elspeth; Casson, Ian; Hennen, Brian; Kelly, Maureen; Korossy, Marika; McNeil, Karen; Abells, Dara; Amaria, Khush; Boyd, Kerry; Gemmill, Meg; Grier, Elizabeth; Kennie-Kaulbach, Natalie; Ketchell, Mackenzie; Ladouceur, Jessica; Lepp, Amanda; Lunsky, Yona; McMillan, Shirley; Niel, Ullanda; Sacks, Samantha; Shea, Sarah; Stringer, Katherine; Sue, Kyle; Witherbee, Sandra

    2018-01-01

    Résumé Objectif Mettre à jour les Lignes directrices consensuelles canadiennes 2011 en matière de soins primaires aux adultes ayant une déficience développementale. Méthodes Des médecins de famille et d’autres professionnels de la santé expérimentés dans les soins aux personnes ayant des DID ont examiné et synthétisé les récentes connaissances empiriques, d’écosystèmes, expertes et expérientielles. Un système a été conçu pour catégoriser la qualité des recommandations. Recommandations Les adultes ayant des DID sont un groupe hétérogène de patients qui présentent des affections médicales et des facteurs qui influent sur leur santé, qui diffèrent de ceux qui touchent les autres membres de la communauté de par leur nature, leurs manifestations, leur gravité ou leur complexité. Ces personnes nécessitent une approche de soins et des interventions adaptées à leurs besoins. Les présentes lignes directrices offrent des conseils en matière de normes de soins. Nous avons incorporé des références à des outils cliniques et à d’autres ressources pratiques. Les approches de soins décrites ici s’appliquent aussi à d’autres groupes de patients ayant un déficit cognitif ou de la communication, ou d’autres déficits des fonctions adaptatives. Conclusion À titre de fournisseurs de soins de première ligne, les médecins de famille jouent un rôle vital de promotion de la santé et de bien-être auprès des adultes ayant des DID. Ces lignes directrices peuvent les aider à prendre des décisions avec les patients et les aidants naturels. PMID:29650617

  3. Continuous-wave operation of a room-temperature, diode-laser-pumped, 946-nm Nd:YAG laser

    NASA Technical Reports Server (NTRS)

    Fan, T. Y.; Byer, Robert L.

    1987-01-01

    Single-stripe diode-laser-pumped operation of a continuous-wave 946-nm Nd:YAG laser with less than 10-mW threshold has been demonstrated. A slope efficiency of 16 percent near threshold was shown with a projected slope efficiency well above a threshold of 34 percent based on results under Rhodamine 6G dye-laser pumping. Nonlinear crystals for second-harmonic generation of this source were evaluated. KNbO3 and periodically poled LiNbO3 appear to be the most promising.

  4. [INVITED] Evaluation of process observation features for laser metal welding

    NASA Astrophysics Data System (ADS)

    Tenner, Felix; Klämpfl, Florian; Nagulin, Konstantin Yu.; Schmidt, Michael

    2016-06-01

    In the present study we show how fast the fluid dynamics change when changing the laser power for different feed rates during laser metal welding. By the use of two high-speed cameras and a data acquisition system we conclude how fast we have to image the process to measure the fluid dynamics with a very high certainty. Our experiments show that not all process features which can be measured during laser welding do represent the process behavior similarly well. Despite the good visibility of the vapor plume the monitoring of its movement is less suitable as an input signal for a closed-loop control. The features measured inside the keyhole show a good correlation with changes of process parameters. Due to its low noise, the area of the keyhole opening is well suited as an input signal for a closed-loop control of the process.

  5. Vents stellaires chauds et nébuleuses éjectées des étoiles chaudes: nécessaire inclusion des phénomènes radiatifs dans les simulations hydrodynamiques

    NASA Astrophysics Data System (ADS)

    Grosdidier, Y.; Garcia-Segura, G.; Acker, A.; Moffat, A. F. J.

    Nous décrivons, à l'instar de la formation et de l'évolution des nébuleuses planétaires, comment l'histoire des vents stellaires issus d'une même étoile chaude (massive ou non) détermine la morphologie des nébuleuses éjectées. Ensuite, nous présentons sommairement la structure et la dynamique des vents accélérés radiativement au sein des étoiles massives (O, Wolf-Rayet) et des étoiles centrales de nébuleuses planétaires de type [WC]. Enfin, nous tâchong d'illustrer en quoi la prise en compte des phénomènes radiatifs est nécessaire pour effectuer toute simulation hydrodynamique sensée reproduire les observations dans les deux contextes, i.e. les vents stellaires chauds eux-mêmes, la persistance de surdensités en leur sein, et les nébuleuses éjectées qui en résultent.

  6. Research of laser stealth performance test technology

    NASA Astrophysics Data System (ADS)

    Chen, Zhen-xing; Shi, Sheng-bing; Han, Fu-li; Wu, Yan-lin; Song, Chun-yan

    2014-09-01

    Laser stealth is an important way of photoelectric stealth weapons systems. According to operational principle of laser range finder, we actively explore and study the stealth performance approval testing technology of laser stealth materials, and bring forward and establish the stealth performance field test methods of stealth efficiency evaluation. Through contrastive test of two kinds of materials, the method is correct and effective.

  7. Comparative evaluation of photoablative efficacy of erbium: yttrium-aluminium-garnet and diode laser for the treatment of gingival hyperpigmentation. A randomized split-mouth clinical trial.

    PubMed

    Giannelli, Marco; Formigli, Lucia; Bani, Daniele

    2014-04-01

    The use of lasers in periodontology is a matter of debate, mainly because of the lack of consensual therapeutic protocols. In this randomized, split-mouth trial, the clinical efficacy of two different photoablative dental lasers, erbium:yttrium-aluminum-garnet (Er:YAG) and diode, for the treatment of gingival hyperpigmentation is compared. Twenty-one patients requiring treatment for mild-to-severe gingival hyperpigmentation were enrolled. Maxillary or mandibular left or right quadrants were randomly subjected to photoablative deepithelialization with either Er:YAG or diode laser. Masked clinical assessments of each laser quadrant were made at admission and days 7, 30, and 180 postoperatively by an independent observer. Histologic examination was performed before and soon after treatment and 6 months after irradiation. Patients also compiled a subjective evaluation questionnaire. Both diode and Er:YAG lasers gave excellent results in gingival hyperpigmentation. However, Er:YAG laser induced deeper gingival tissue injury than diode laser, as judged by bleeding at surgery, delayed healing, and histopathologic analysis. The use of diode laser showed additional advantages compared to Er:YAG in terms of less postoperative discomfort and pain. This study highlights the efficacy of diode laser for photoablative deepithelialization of hyperpigmented gingiva. It is suggested that this laser can represent an effective and safe therapeutic option for gingival photoablation.

  8. A laser spectrometer and wavemeter for pulsed lasers

    NASA Technical Reports Server (NTRS)

    Mckay, J. A.; Laufer, P. M.; Cotnoir, L. J.

    1989-01-01

    The design, construction, calibration, and evaluation of a pulsed laser wavemeter and spectral analyzer are described. This instrument, called the Laserscope for its oscilloscope-like display of laser spectral structure, was delivered to NASA Langley Research Center as a prototype of a laboratory instrument. The key component is a multibeam Fizeau wedge interferometer, providing high (0.2 pm) spectral resolution and a linear dispersion of spectral information, ideally suited to linear array photodiode detectors. Even operating alone, with the classic order-number ambiguity of interferometers unresolved, this optical element will provide a fast, real-time display of the spectral structure of a laser output. If precise wavelength information is also desired then additional stages must be provided to obtain a wavelength measurement within the order-number uncertainty, i.e., within the free spectral range of the Fizeau wedge interferometer. A Snyder (single-beam Fizeau) wedge is included to provide this initial wavelength measurement. Difficulties in achieving the required wide-spectrum calibration limit the usefulness of this function.

  9. Fractional carbon dioxide laser for the treatment of facial atrophic acne scars: prospective clinical trial with short and long-term evaluation.

    PubMed

    Elcin, Gonca; Yalici-Armagan, Basak

    2017-12-01

    The aim of this study was to evaluate the efficacy and safety of fractional carbon dioxide laser for the treatment of acne scars. Thirty-one participants, 15 female and 16 male, whose mean age was 34.84 ± 10.94 years, were included in this prospective study. The study took place between 2012 and 2016. Participants were evaluated with the "ECCA Grading Scale" before the first session, 3 months (short-term evaluation) and 3 years after the last session (long-term evaluation). Participants received two or three treatment sessions at 4-week intervals, with a 10,600 nm fractional carbon dioxide laser with pulse energies ranging between 100 and 160 mJ, 120 spot type, 75-100 spot/cm 2 density, and 30 W power. Self-assessments by the participants were done 3 months and 3 years after the last session. The mean ECCA score was 107.90 ± 39.38 before the first session, and 82.17 ± 36.23 at the time of short-term evaluation (p = 0.000). The grade of improvement at the short-term evaluation was as follows: no improvement, mild, moderate, and significant improvement for 7 (22.6%), 11 (35.5%), 9 (29%), and 4 (12.9%) of the participants, respectively. Regarding self-assessments, 80.6 and 61.3% of the participants rated themselves as having at least mild improvement at the short-term and the long-term follow-up periods, respectively. The results of this study suggest that fractional carbon dioxide laser is an efficient treatment option for acne scars. Furthermore, self-assessment results show that more than half of the participants still experience at least mild improvement at the end of 3 years.

  10. Preliminary clinical results with the ISL laser

    NASA Astrophysics Data System (ADS)

    Hoppeler, Thomas; Gloor, Balder

    1992-08-01

    The ISL laser (Intelligent Surgical Lasers, Inc.), a Nd:YLF picosecond pulse laser, is currently being used under investigational device exemption to perform microsurgery of the anterior segment of the eye. At different study sites procedures for cataract fragmentation and iridotomy, as well as for posterior capsulotomy after cataract surgery, are under evaluation. Other potential applications include: sclerostomy ab interno, the cutting of membranes in the anterior and posterior segment of the eye; corneal incisions; and corneal intrastromal effects. We discuss various clinically relevant aspects of the use of this picosecond laser. An overview of different computer controlled laser patterns is given.

  11. Evaluating inner surface roughness of inline/picoliter fiber optic spectrometer fabricated by an NUV femtosecond laser drilling

    NASA Astrophysics Data System (ADS)

    Shiraishi, Masahiko; Kubodera, Shoichi; Watanabe, Kazuhiro

    2017-05-01

    We have evaluated inner surface roughness of inline/picoliter fiber optic spectrometer fabricated by an NUV femtosecond laser drilling. A microhole fabricated by the femtosecond laser without breaking off works as inline/picoliter fiber optic spectrometer. The attractive feature of the spectrometer is very small sensing volume which has several tens of picoliter. A second harmonic 400 nm femtosecond laser with 350 fs pulse duration launched onto the glass fiber optic. A high aspect ratio of the microhole was fabricated after 1000 pulse shots, but there was inner surface roughness. Although the repetition rate was changed 10 to 1000 Hz in order to control the inner surface roughness, the inner surface roughness was occurred in each case. It was confirmed that ablated fused silica particles deposited on the inner surface of microhole. The depth of microhole was deepened with 1 kHz of repetition rate and number of 1000 shots. In comparison to 10 Hz, the depth of microhole was increased by approximately 80%. It was assumed that heat accumulation effect enlarged the length of drilling. In order to minimize inner surface roughness, the best method is to use low number laser shots. After 100 pulse shots with 30 μJ of pulse energy, an optical inner surface quality of microhole was acquired. The optical inner surface quality of microhole was verified by measuring the transmittance of 94% of infrared light emission launched from superluminescent diode in the case of 100 pulse shots with 20 μJ. The transmittance decreased to 52% changing the microhole fabricated by 30 μJ with 100 laser shots because of increasing interaction area between the microhole and propagating light.

  12. Manipulating the wavelength-drift of a Tm laser for resonance enhancement in an intra-cavity pumped Ho laser.

    PubMed

    Huang, Haizhou; Huang, Jianhong; Liu, Huagang; Li, Jinhui; Lin, Zixiong; Ge, Yan; Dai, Shutao; Deng, Jing; Lin, Wenxiong

    2018-03-05

    We demonstrate an enhancement mechanism and thermal model for intra-cavity pumped lasers, where resonance enhancement in intra-cavity pumped Ho laser was achieved by manipulating the wavelength-drift nature of the Tm laser for the first time. Optical conversion efficiency of 37.5% from an absorbed 785 nm diode laser to a Ho laser was obtained with a maximum output power of 7.51 W at 2122 nm, which is comparable to the conversion efficiency in 1.9 μm LD pumped Ho lasers. Meanwhile, more severe thermal effects in the Ho-doped gain medium than the Tm-doped one at high power operation were verified based on the built thermal model. This work benefits the design or evaluation of intra-cavity pumped lasers, and the resonance enhancement originated from the difference in reabsorption loss between stark levels at the lasing manifolds of quasi-three-level rare-earth ions has great interest to improve the existing intra-cavity pumped lasers or explore novel lasers.

  13. Evaluation of thermal load during laser corneal refractive surgery using infrared thermography

    NASA Astrophysics Data System (ADS)

    Brunsmann, U.; Sauer, U.; Arba-Mosquera, S.; Magnago, T.; Triefenbach, N.

    2010-09-01

    Infrared thermography is used for evaluation of the mean temperature as a measure of thermal load during corneal refractive surgery. An experimental method to determine emissivity and to calibrate the thermografic system is presented. In a case study on the porcine eye two dimensional temperature distributions with lateral resolution of 170 μm and line scans with temporal resolution of 13 μs are discussed with respect to the meaning of mean temperature. Using the newest generation of surgery equipment it is shown, that the mean temperature rise can be kept below 5 °C during myopic laser in situ keratomileusis (LASIK) treatments corresponding to an aberration-free correction of -2.75 diopter.

  14. Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters.

    PubMed

    Bello-Silva, Marina Stella; Wehner, Martin; Eduardo, Carlos de Paula; Lampert, Friedrich; Poprawe, Reinhart; Hermans, Martin; Esteves-Oliveira, Marcella

    2013-01-01

    This study aimed to evaluate the possibility of introducing ultra-short pulsed lasers (USPL) in restorative dentistry by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages, such as thermal damage of irradiated substrate. USPL ablation of dental hard tissues was investigated in two phases. Phase 1--different wavelengths (355, 532, 1,045, and 1,064 nm), pulse durations (picoseconds and femtoseconds) and irradiation parameters (scanning speed, output power, and pulse repetition rate) were assessed for enamel and dentin. Ablation rate was determined, and the temperature increase measured in real time. Phase 2--the most favorable laser parameters were evaluated to correlate temperature increase to ablation rate and ablation efficiency. The influence of cooling methods (air, air-water spray) on ablation process was further analyzed. All parameters tested provided precise and selective tissue ablation. For all lasers, faster scanning speeds resulted in better interaction and reduced temperature increase. The most adequate results were observed for the 1064-nm ps-laser and the 1045-nm fs-laser. Forced cooling caused moderate changes in temperature increase, but reduced ablation, being considered unnecessary during irradiation with USPL. For dentin, the correlation between temperature increase and ablation efficiency was satisfactory for both pulse durations, while for enamel, the best correlation was observed for fs-laser, independently of the power used. USPL may be suitable for cavity preparation in dentin and enamel, since effective ablation and low temperature increase were observed. If adequate laser parameters are selected, this technique seems to be promising for promoting the laser-assisted, minimally invasive approach.

  15. [Evaluation of the efficacy of diode laser endocyclophotocoagulation combined with cataract surgery in glaucoma].

    PubMed

    Ezzouhairi, S M

    2015-11-01

    Surgical techniques, which reduce the secretion of aqueous humor are underutilized in the surgical management of glaucoma; the diode laser coupled to an endoscope, endocyclophotocoagulation (ECP), is an emerging technology in the treatment of glaucoma. Indeed, thanks to its direct, focal and controllable approach to diode laser treatment of the ciliary processes, ECP renders this a safer technique compared to transscleral diode laser. We present preliminary results and an evaluation of the efficacy of ECP combined with cataract surgery performed at the Al Bassar clinic in Mohammedia, Morocco. We conducted a retrospective study on a series of 82 patients who underwent combined surgery: diode laser endocyclophotocoagulation and cataract for treatment of glaucoma during the period from December 2012 to July 2013. For this study, we recorded: age and gender of the patients, number and power of diode laser spots, pre- and postoperative intraocular pressure (IOP), and the number of anti-glaucoma treatments prescribed pre- and postoperatively (3 months minimum). Technically, a 20-gauge endo-ocular probe is inserted through the corneal incision used for phacoemulsification. The probe is equipped with a light source, a camera and a pulsed 810 nm laser beam; it is connected to an Endo-optiks type generator, which allows for direct visualization of the ciliary processes and their precise treatment. The surgical procedure is both simple and quick. Postoperative follow-up is unchanged from the management of cataract extraction by phacoemulsification. The average age in our series was 69.5 years (range 33-81 years), mean follow-up was 5.7 months. The reduction in intraocular pressure was 28.5%. In 40% of patients, a significant reduction in medications was noted, and in 20%, a total suspension of anti-glaucoma medications. No serious complications were noted in our series. This technique can perfectly fit into the medical, natural and/or surgical armamentarium medical, physical

  16. Laser welding process in PP moulding parts: Evaluation of seam performance

    NASA Astrophysics Data System (ADS)

    Oliveira, N.; Pontes, A. J.

    2015-12-01

    The Polypropylene is one of the most versatile polymer materials used in the industry. Due to this versatility, it is possible to use it in different products. This material can also be mixed with several additives namely glass fiber, carbon nanotubes, etc. This compatibility with different additives allows also obtaining products with characteristics that goes from an impact absorber to an electricity conductor. When is necessary to join components in PP they could be welded through hot plate, ultrasonic weld and also by laser. This study had the objective of study the influence of several variables, capable of influence the final quality of the seam. In this case were studied variables of the injection molding process as mold temperature and cooling time. Was also studied laser welding variables and different materials. The results showed that the variables that have the most influence were mould temperature, laser velocity and laser diameter. The seams were analyzed using Optical Microscopy technique. The seams showed perfect contact between the materials analyzed, despite the high standard variation presented in the mechanical testes.

  17. Initial evaluation of commercially available InGaAsP DFB laser diodes for use in high-speed digital fiber optic transceivers

    NASA Technical Reports Server (NTRS)

    Cook, Anthony L.; Hendricks, Herbert D.

    1990-01-01

    NASA has been pursuing the development of high-speed fiber-optic transceivers for use in a number of space data system applications. Current efforts are directed toward a high-performance all-integrated-circuit transceiver operating up to the 3-5 Gb/s range. Details of the evaluation and selection of candidate high-speed optical sources to be used in the space-qualified high-performance transceiver are presented. Data on the performance of commercially available DFB (distributed feedback) lasers are presented, and their performance relative to each other and to their structural design with regard to their use in high-performance fiber-optic transceivers is discussed. The DFB lasers were obtained from seven commercial manufacturers. The data taken on each laser included threshold current, differential quantum efficiency, CW side mode suppression radio, wavelength temperature coefficient, threshold temperature coefficient, natural linewidth, and far field pattern. It was found that laser diodes with buried heterostructures and first-order gratings had, in general, the best CW operating characteristics. The modulated characteristics of the DFB laser diodes are emphasized. Modulated linewidth, modulated side mode suppression ratio, and frequency response are discussed.

  18. Methodes de calcul des forces aerodynamiques pour les etudes des interactions aeroservoelastiques

    NASA Astrophysics Data System (ADS)

    Biskri, Djallel Eddine

    L'aeroservoelasticite est un domaine ou interagissent la structure flexible d'un avion, l'aerodynamique et la commande de vol. De son cote, la commande du vol considere l'avion comme une structure rigide et etudie l'influence du systeme de commande sur la dynamique de vol. Dans cette these, nous avons code trois nouvelles methodes d'approximation de forces aerodynamiques: Moindres carres corriges, Etat minimal corrige et Etats combines. Dans les deux premieres methodes, les erreurs d'approximation entre les forces aerodynamiques approximees par les methodes classiques et celles obtenues par les nouvelles methodes ont les memes formes analytiques que celles des forces aerodynamiques calculees par LS ou MS. Quant a la troisieme methode, celle-ci combine les formulations des forces approximees avec les methodes standards LS et MS. Les vitesses et frequences de battement et les temps d'executions calcules par les nouvelles methodes versus ceux calcules par les methodes classiques ont ete analyses.

  19. Determinants of holmium:yttrium-aluminum-garnet laser time and energy during ureteroscopic laser lithotripsy.

    PubMed

    Molina, Wilson R; Marchini, Giovanni S; Pompeo, Alexandre; Sehrt, David; Kim, Fernando J; Monga, Manoj

    2014-04-01

    To evaluate the association of preoperative noncontrast computed tomography stone characteristics, laser settings, and stone composition with cumulative holmium:yttrium-aluminum-garnet (Ho:YAG) laser time/energy. We retrospectively reviewed patients who underwent semirigid/flexible ureteroscopy and Ho:YAG laser lithotripsy (200 or 365 μm laser fiber; 0.8-1.0 J energy; and 8-10 Hz rate) at 2 tertiary care centers (April 2010-May 2012). Studied parameters were as follows: patient's characteristics; stone characteristics (location, burden, hardness, and composition); total laser time and energy; and surgical outcomes. One hundred patients met our inclusion criteria. Mean stone size was 1.01 ± 0.42 cm and volume 0.33 ± 0.04 cm(3). Mean stone radiodensity was 990 ± 296 HU, and Hounsfield units density 13.8 ± 6.0 HU/mm. All patients were considered stone free. Stone size and volume had a significant positive correlation with laser energy (R = 0.516, P <.001; R = 0.621, P <.001) and laser time (R = 0.477, P <.001; R = 0.567, P <.001). When controlling for stone size, only the correlation between HU and laser time was significant (R = 0.262, P = .011). In the multivariate analysis, with exception of stone composition (P = .103), all parameters significantly increased laser energy (R(2) = 0.524). Multivariate analysis revealed a positive significant association of laser time with stone volume (P <.001) and Hounsfield units density (P <.001; R(2) = 0.512). In multivariate analysis for laser energy, only calcium phosphate stones required less energy to fragment compared with uric acid stones. No significant differences were found in the multivariate laser time model. Ho:YAG laser cumulative energy and total time are significantly affected by stone dimensions, hardness location, fiber size, and power. Kidney location, laser fiber size, and laser power have more influence on the final laser energy than on the total laser time. Calcium phosphate stones require less laser

  20. E-beam-pumped semiconductor lasers

    NASA Astrophysics Data System (ADS)

    Rice, Robert R.; Shanley, James F.; Ruggieri, Neil F.

    1995-04-01

    The collapse of the Soviet Union opened many areas of laser technology to the West. E-beam- pumped semiconductor lasers (EBSL) were pursued for 25 years in several Soviet Institutes. Thin single crystal screens of II-VI alloys (ZnxCd1-xSe, CdSxSe1-x) were incorporated in laser CRTs to produce scanned visible laser beams at average powers greater than 10 W. Resolutions of 2500 lines were demonstrated. MDA-W is conducting a program for ARPA/ESTO to assess EBSL technology for high brightness, high resolution RGB laser projection application. Transfer of II-VI crystal growth and screen processing technology is underway, and initial results will be reported. Various techniques (cathodoluminescence, one- and two-photon laser pumping, etc.) have been used to assess material quality and screen processing damage. High voltage (75 kV) video electronics were procured in the U.S. to operate test EBSL tubes. Laser performance was documented as a function of screen temperature, beam voltage and current. The beam divergence, spectrum, efficiency and other characteristics of the laser output are being measured. An evaluation of the effect of laser operating conditions upon the degradation rate is being carried out by a design-of-experiments method. An initial assessment of the projected image quality will be performed.