Talar anchor placement for modified Brostrom lateral ankle stabilization procedure.
Angirasa, Arush K; Barrett, Michael J
2008-01-01
The modified Brostrom procedure has been a proven procedure with excellent utility in the treatment of lateral ankle instability within limitation. Multiple variations of the original technique have been described in the literature to date. Included in these variations are differences in anchor placement, suture technique, or both. In this research study, we propose placing a bone screw anchor into the lateral shoulder of the talus rather than the typical placement at the lateral malleolus for anatomic reconstruction of the lateral ankle ligaments.
Stability-maneuverability trade-offs during lateral steps.
Acasio, Julian; Wu, Mengnan/Mary; Fey, Nicholas P; Gordon, Keith E
2017-02-01
Selecting a specific foot placement strategy to perform walking maneuvers requires the management of several competing factors, including: maintaining stability, positioning oneself to actively generate impulses, and minimizing mechanical energy requirements. These requirements are unlikely to be independent. Our purpose was to determine the impact of lateral foot placement on stability, maneuverability, and energetics during walking maneuvers. Ten able-bodied adults performed laterally-directed walking maneuvers. Mediolateral placement of the "Push-off" foot during the maneuvers was varied, ranging from a cross-over step to a side-step. We hypothesized that as mediolateral foot placement became wider, passive stability in the direction of the maneuver, the lateral impulse generated to create the maneuver, and mechanical energy cost would all increase. We also hypothesized that subjects would prefer an intermediate step width reflective of trade-offs between stability vs. both maneuverability and energy. In support of our first hypothesis, we found that as Push-off step width increased, lateral margin of stability, peak lateral impulse, and total joint work all increased. In support of our second hypothesis, we found that when subjects had no restrictions on their mediolateral foot placement, they chose a foot placement between the two extreme positions. We found a significant relationship (p<0.05) between lateral margin of stability and peak lateral impulse (r=0.773), indicating a trade-off between passive stability and the force input required to maneuver. These findings suggest that during anticipated maneuvers people select foot placement strategies that balance competing costs to maintain stability, actively generate impulses, and minimize mechanical energy costs. Published by Elsevier B.V.
Al-Almaie, Saad; Kavarodi, Abdul Majeed; Alorf, Ali; Alzahrani, Saeed
2017-01-01
The objective of this study is to compare and evaluate the effectiveness of implant placement and patient appraisal for two sinus lift techniques using both crestal and lateral techniques for bilateral sinus left in a split-mouth design. All implants were successfully osseointegrated without any clinical complications or peri-implant radiolucency during the follow-up period of maximum 3 years. In terms of outcomes postoperative vertigo showed to be a major concern with the crestal approach, this approach is preferred over the lateral technique because of the reduced time required for the procedure and because it is less invasive. Most patients preferred the crestal approach over the lateral approach due to the delay in implant placement.
Effect of Running Speed and Leg Prostheses on Mediolateral Foot Placement and Its Variability
Arellano, Christopher J.; McDermott, William J.; Kram, Rodger; Grabowski, Alena M.
2015-01-01
This study examined the effects of speed and leg prostheses on mediolateral (ML) foot placement and its variability in sprinters with and without transtibial amputations. We hypothesized that ML foot placement variability would: 1. increase with running speed up to maximum speed and 2. be symmetrical between the legs of non-amputee sprinters but asymmetrically greater for the affected leg of sprinters with a unilateral transtibial amputation. We measured the midline of the body (kinematic data) and center of pressure (kinetic data) in the ML direction while 12 non-amputee sprinters and 7 Paralympic sprinters with transtibial amputations (6 unilateral, 1 bilateral) ran across a range of speeds up to maximum speed on a high-speed force measuring treadmill. We quantified ML foot placement relative to the body’s midline and its variability. We interpret our results with respect to a hypothesized relation between ML foot placement variability and lateral balance. We infer that greater ML foot placement variability indicates greater challenges with maintaining lateral balance. In non-amputee sprinters, ML foot placement variability for each leg increased substantially and symmetrically across speed. In sprinters with a unilateral amputation, ML foot placement variability for the affected and unaffected leg also increased substantially, but was asymmetric across speeds. In general, ML foot placement variability for sprinters with a unilateral amputation was within the range observed in non-amputee sprinters. For the sprinter with bilateral amputations, both affected legs exhibited the greatest increase in ML foot placement variability with speed. Overall, we find that maintaining lateral balance becomes increasingly challenging at faster speeds up to maximum speed but was equally challenging for sprinters with and without a unilateral transtibial amputation. Finally, when compared to all other sprinters in our subject pool, maintaining lateral balance appears to be the most challenging for the Paralympic sprinter with bilateral transtibial amputations. PMID:25590634
Al-Almaie, Saad; Kavarodi, Abdul Majeed; Alorf, Ali; Alzahrani, Saeed
2017-01-01
Objective: The objective of this study is to compare and evaluate the effectiveness of implant placement and patient appraisal for two sinus lift techniques using both crestal and lateral techniques for bilateral sinus left in a split-mouth design. Introduction: All implants were successfully osseointegrated without any clinical complications or peri-implant radiolucency during the follow-up period of maximum 3 years. Methods: In terms of outcomes postoperative vertigo showed to be a major concern with the crestal approach, this approach is preferred over the lateral technique because of the reduced time required for the procedure and because it is less invasive. Results: Most patients preferred the crestal approach over the lateral approach due to the delay in implant placement. PMID:29290838
A neuromechanical strategy for mediolateral foot placement in walking humans.
Rankin, Bradford L; Buffo, Stephanie K; Dean, Jesse C
2014-07-15
Stability is an important concern during human walking and can limit mobility in clinical populations. Mediolateral stability can be efficiently controlled through appropriate foot placement, although the underlying neuromechanical strategy is unclear. We hypothesized that humans control mediolateral foot placement through swing leg muscle activity, basing this control on the mechanical state of the contralateral stance leg. Participants walked under Unperturbed and Perturbed conditions, in which foot placement was intermittently perturbed by moving the right leg medially or laterally during the swing phase (by ∼50-100 mm). We quantified mediolateral foot placement, electromyographic activity of frontal-plane hip muscles, and stance leg mechanical state. During Unperturbed walking, greater swing-phase gluteus medius (GM) activity was associated with more lateral foot placement. Increases in GM activity were most strongly predicted by increased mediolateral displacement between the center of mass (CoM) and the contralateral stance foot. The Perturbed walking results indicated a causal relationship between stance leg mechanics and swing-phase GM activity. Perturbations that reduced the mediolateral CoM displacement from the stance foot caused reductions in swing-phase GM activity and more medial foot placement. Conversely, increases in mediolateral CoM displacement caused increased swing-phase GM activity and more lateral foot placement. Under both Unperturbed and Perturbed conditions, humans controlled their mediolateral foot placement by modulating swing-phase muscle activity in response to the mechanical state of the contralateral leg. This strategy may be disrupted in clinical populations with a reduced ability to modulate muscle activity or sense their body's mechanical state.
Wang, Yingsong; Xie, Jingming; Yang, Zhendong; Zhao, Zhi; Zhang, Ying; Li, Tao; Liu, Luping
2013-07-01
To present the technique of free-hand subaxial cervical pedicle screw (CPS) placement without using intra-operative navigating devices, and to investigate the crucial factors for safe placement and avoidance of lateral pedicle wall perforation, by measuring and classifying perforations with postoperative computed tomography (CT) scan. The placement of CPS has generally been considered as technically demanding and associated with considerable lateral wall perforation rate. For surgeons without access to navigation systems, experience of safe free-hand technique for subaxial CPS placement is especially valuable. A total of 214 consecutive traumatic or degenerative patients with 1,024 CPS placement using the free-hand technique were enrolled. In the operative process, the lateral mass surface was decorticated. Then a small curette was used to identify the pedicle entrance by touching the cortical bone of the medial pedicle wall. It was crucial to keep the transverse angle and make appropriate adjustment with guidance of the resistance of the thick medial cortical bone. The hand drill should be redirected once soft tissue breach was palpated by a slim ball-tip prober. With proper trajectory, tapping, repeated palpation, the 26-30 mm screw could be placed. After the procedure, the transverse angle of CPS trajectory was measured, and perforation of the lateral wall was classified by CT scan: grade 1, perforation of pedicle wall by screw placement, with the external edge of screw deviating out of the lateral pedicle wall equal to or less than 2 mm and grade 2, critical perforation of pedicle wall by screw placement, large than 2 mm. A total of 129 screws (12.64 %) were demonstrated as lateral pedicle wall perforation, of which 101 screws (9.86 %) were classified as grade 1, whereas 28 screws (2.73 %) as grade 2. Among the segments involved, C3 showed an obviously higher perforating rate than other (P < 0.05). The difference between the anatomical pedicle transverse angle and the screw trajectory angle was higher in patients of grade 2 perforation than the others. In the 28 screws of grade 2 perforation verified by axial CT, 26 screws had been palpated as abnormal during operation. However, only 19 out of the 101 screws of grade 1 perforation had shown palpation alarming signs during operation. The average follow-up was 36.8 months (range 5-65 months). There was no symptom and sign of neurovascular injuries. Two screws (0.20 %) were broken, and one screw (0.10 %) loosen. Placement of screw through a correct trajectory may lead to grade 1 perforation, which suggests transversal expansion and breakage of the thinner lateral cortex, probably caused by mismatching of the diameter of 3.5 mm screws and the tiny cancellous bone cavity of pedicle. Grade 1 perforation is deemed as relatively safe to the vertebral artery. Grade 2 perforation means obvious deviation of the trajectory angle of hand drill, which directly penetrates into the transverse foramen, and the risk of vertebral artery injury (VAI) or development of thrombi caused by the irregular blood flow would be much greater compared to grade 1 perforation. Moreover, there are two crucial maneuvers for increasing accuracy of screw placement: identifying the precise entry point using a curette or hand drill to touch the true entrance of the canal after decortication, and guiding CPS trajectory on axial plane by the resistant of thick medial wall.
Nagashima, Kazuaki; Furuta, Natsumi; Makioka, Kouki; Fujita, Yukio; Ikeda, Masaki; Ikeda, Yoshio
2017-05-15
A percutaneous endoscopic gastrostomy (PEG) is an useful intervention for feeding of amyotrophic lateral sclerosis (ALS) patients who have lost oral intake function. The aim of this study was to investigate the risk factors for early death and the survival after PEG placement. A total of 102 ALS patients who underwent PEG placement were enrolled in this study. Patients were divided into two groups; the poor prognosis group included patients who died or needed permanent mechanical ventilation within 30days after PEG placement, and the good prognosis group included patients who did not meet the criteria of the poor prognosis group. Clinical characteristics, respiratory function, and nutritional parameters were compared for the two groups to assess the correlations between clinical and laboratory variables and early death after PEG placement. Multivariate analysis between two groups revealed that higher arterial carbon dioxide pressure (PaCO 2 ) and aphagia before PEG placement were significantly associated with the poor prognosis group. Multivariate analysis for survival also revealed that higher PaCO 2 and shorter duration from onset to PEG placement were significantly associated with shorter survival after PEG placement. In conclusion, respiratory and nutritional parameters are revealed to be important prognostic factors for ALS patients who undergo PEG placement. Copyright © 2017 Elsevier B.V. All rights reserved.
Sundar, Swetha J; Healy, Andrew T; Kshettry, Varun R; Mroz, Thomas E; Schlenk, Richard; Benzel, Edward C
2016-05-01
OBJECTIVE Pedicle and lateral mass screw placement is technically demanding due to complex 3D spinal anatomy that is not easily visualized. Neurosurgical and orthopedic surgery residents must be properly trained in such procedures, which can be associated with significant complications and associated morbidity. Current training in pedicle and lateral mass screw placement involves didactic teaching and supervised placement in the operating room. The objective of this study was to assess whether teaching residents to place pedicle and lateral mass screws using navigation software, combined with practice using cadaveric specimens and Sawbones models, would improve screw placement accuracy. METHODS This was a single-blinded, prospective, randomized pilot study with 8 junior neurosurgical residents and 2 senior medical students with prior neurosurgery exposure. Both the study group and the level of training-matched control group (each group with 4 level of training-matched residents and 1 senior medical student) were exposed to a standardized didactic education regarding spinal anatomy and screw placement techniques. The study group was exposed to an additional pilot program that included a training session using navigation software combined with cadaveric specimens and accessibility to Sawbones models. RESULTS A statistically significant reduction in overall surgical error was observed in the study group compared with the control group (p = 0.04). Analysis by spinal region demonstrated a significant reduction in surgical error in the thoracic and lumbar regions in the study group compared with controls (p = 0.02 and p = 0.04, respectively). The study group also was observed to place screws more optimally in the cervical, thoracic, and lumbar regions (p = 0.02, p = 0.04, and p = 0.04, respectively). CONCLUSIONS Surgical resident education in pedicle and lateral mass screw placement is a priority for training programs. This study demonstrated that compared with a didactic-only training model, using navigation simulation with cadavers and Sawbones models significantly reduced the number of screw placement errors in a laboratory setting.
Portal placement in elbow arthroscopy by novice surgeons: cadaver study.
Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N
2017-07-01
In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p < 0.001), the lateral antebrachial cutaneous nerve (4.0 mm, p < 0.001), and the radial nerve (25 mm, p < 0.001) was different from the average reported distances in the literature. A difference was found between the distance of the anterolateral portal and the PABCN (32 mm, p < 0.001) compared to previous studies. Three major iatrogenic complications were observed, including: laceration of the posterior bundle of the medial ulnar collateral ligament, lateral ulnar collateral ligament midsubstance laceration, and median nerve partial laceration. Surgeons increasingly consider arthroscopic treatment as an option for elbow pathology. In the present study a surgical complication rate of 30 % was found with novice portal placement during elbow arthroscopy. Furthermore, as the results from this study have indicated, accurate, precise, and safe portal placement in elbow arthroscopy is not easily achieved by didactic lecture and cadaver instruction session alone. Level of evidence V.
Balasubramanian, Chitralakshmi K.; Neptune, Richard R.; Kautz, Steven A.
2010-01-01
Background Foot placement during walking is closely linked to the body position, yet it is typically quantified relative to the other foot. The purpose of this study was to quantify foot placement patterns relative to body post-stroke and investigate its relationship to hemiparetic walking performance. Methods Thirty-nine participants with hemiparesis walked on a split-belt treadmill at their self-selected speeds and twenty healthy participants walked at matched slow speeds. Anterior-posterior and medial-lateral foot placements (foot center-of-mass) relative to body (pelvis center-of-mass) quantified stepping in body reference frame. Walking performance was quantified using step length asymmetry ratio, percent of paretic propulsion and paretic weight support. Findings Participants with hemiparesis placed their paretic foot further anterior than posterior during walking compared to controls walking at matched slow speeds (p < .05). Participants also placed their paretic foot further lateral relative to pelvis than non-paretic (p < .05). Anterior-posterior asymmetry correlated with step length asymmetry and percent paretic propulsion but some persons revealed differing asymmetry patterns in the translating reference frame. Lateral foot placement asymmetry correlated with paretic weight support (r = .596; p < .001), whereas step widths showed no relation to paretic weight support. Interpretation Post-stroke gait is asymmetric when quantifying foot placement in a body reference frame and this asymmetry related to the hemiparetic walking performance and explained motor control mechanisms beyond those explained by step lengths and step widths alone. We suggest that biomechanical analyses quantifying stepping performance in impaired populations should investigate foot placement in a body reference frame. PMID:20193972
Balasubramanian, Chitralakshmi K; Neptune, Richard R; Kautz, Steven A
2010-06-01
Foot placement during walking is closely linked to the body position, yet it is typically quantified relative to the other foot. The purpose of this study was to quantify foot placement patterns relative to body post-stroke and investigate its relationship to hemiparetic walking performance. Thirty-nine participants with hemiparesis walked on a split-belt treadmill at their self-selected speeds and 20 healthy participants walked at matched slow speeds. Anterior-posterior and medial-lateral foot placements (foot center-of-mass) relative to body (pelvis center-of-mass) quantified stepping in body reference frame. Walking performance was quantified using step length asymmetry ratio, percent of paretic propulsion and paretic weight support. Participants with hemiparesis placed their paretic foot further anterior than posterior during walking compared to controls walking at matched slow speeds (P<.05). Participants also placed their paretic foot further lateral relative to pelvis than non-paretic (P<.05). Anterior-posterior asymmetry correlated with step length asymmetry and percent paretic propulsion but some persons revealed differing asymmetry patterns in the translating reference frame. Lateral foot placement asymmetry correlated with paretic weight support (r=.596; P<.001), whereas step widths showed no relation to paretic weight support. Post-stroke gait is asymmetric when quantifying foot placement in a body reference frame and this asymmetry related to the hemiparetic walking performance and explained motor control mechanisms beyond those explained by step lengths and step widths alone. We suggest that biomechanical analyses quantifying stepping performance in impaired populations should investigate foot placement in a body reference frame. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Bowens, Clifford; Gupta, Rajnish K; O'Byrne, William T; Schildcrout, Jonathan S; Shi, Yaping; Hawkins, Jermel J; Michaels, Damon R; Berry, James M
2010-05-01
In this study, we performed the infraclavicular block with combined ultrasound guidance and neurostimulation to selectively target cords to compare the success rates of placing a single injection of local anesthetic either in a central or peripheral location. Two hundred eighteen patients were enrolled in a consecutive, prospective study. Patients were randomized to injection of local anesthetic either centrally (posterior cord) or peripherally (medial or lateral cord) using ultrasound guidance and neurostimulation. Supervised senior anesthesiology residents or attending anesthesiologists performed the blocks. Both intent-to-treat and treatment-received analyses were used to compare central and peripheral placement efficacy. The overall success rate was significantly higher for the central placements than peripheral placements (96% vs 85%, P = 0.004). Individual cord success rates were as follows: posterior 99%, lateral 92%, and medial 84% (P = 0.001). The central group required attending physician intervention more frequently (27% vs 6%, P < 0.001). Postoperative pain scores of < or =3 were more likely with central placement (100% vs 94%, P = 0.012). Central placement of a single injection of local anesthetic targeted at the posterior cord resulted in a higher success rate for infraclavicular block.
Uribe, Juan S; Smith, Donald A; Dakwar, Elias; Baaj, Ali A; Mundis, Gregory M; Turner, Alexander W L; Cornwall, G Bryan; Akbarnia, Behrooz A
2012-11-01
In the surgical treatment of spinal deformities, the importance of restoring lumbar lordosis is well recognized. Smith-Petersen osteotomies (SPOs) yield approximately 10° of lordosis per level, whereas pedicle subtraction osteotomies result in as much as 30° increased lumbar lordosis. Recently, selective release of the anterior longitudinal ligament (ALL) and placement of lordotic interbody grafts using the minimally invasive lateral retroperitoneal transpsoas approach (XLIF) has been performed as an attempt to increase lumbar lordosis while avoiding the morbidity of osteotomy. The objective of the present study was to measure the effect of the selective release of the ALL and varying degrees of lordotic implants placed using the XLIF approach on segmental lumbar lordosis in cadaveric specimens between L-1 and L-5. Nine adult fresh-frozen cadaveric specimens were placed in the lateral decubitus position. Lateral radiographs were obtained at baseline and after 4 interventions at each level as follows: 1) placement of a standard 10° lordotic cage, 2) ALL release and placement of a 10° lordotic cage, 3) ALL release and placement of a 20° lordotic cage, and 4) ALL release and placement of a 30° lordotic cage. All four cages were implanted sequentially at each interbody level between L-1 and L-5. Before and after each intervention, segmental lumbar lordosis was measured in all specimens at each interbody level between L-1 and L-5 using the Cobb method on lateral radiography. The mean baseline segmental lordotic angles at L1-2, L2-3, L3-4, and L4-5 were -3.8°, 3.8°, 7.8°, and 22.6°, respectively. The mean lumbar lordosis was 29.4°. Compared with baseline, the mean postimplantation increase in segmental lordosis in all levels combined was 0.9° in Intervention 1 (10° cage without ALL release); 4.1° in Intervention 2 (ALL release with 10° cage); 9.5° in Intervention 3 (ALL release with 20° cage); and 11.6° in Intervention 4 (ALL release with 30° cage). Foraminal height in the same sequence of conditions increased by 6.3%, 4.6%, 8.8% and 10.4%, respectively, while central disc height increased by 16.1%, 22.3%, 52.0% and 66.7%, respectively. Following ALL release and placement of lordotic cages at all 4 lumbar levels, the average global lumbar lordosis increase from preoperative lordosis was 3.2° using 10° cages, 12.0° using 20° cages, and 20.3° using 30° cages. Global lumbar lordosis with the cages at 4 levels exhibited a negative correlation with preoperative global lordosis (10°, R = -0.756; 20°, -0.730; and 30°, R = -0.437). Combined ALL release and placement of increasingly lordotic lateral interbody cages leads to progressive gains in segmental lordosis in the lumbar spine. Mean global lumbar lordosis similarly increased with increasingly lordotic cages, although the effect with a single cage could not be evaluated. Greater global lordosis was achieved with smaller preoperative lordosis. The mean maximum increase in segmental lordosis of 11.6° followed ALL release and placement of the 30° cage.
Castellanos-Cosano, Lizett; Corcuera-Flores, José-Ramón; Mesa-Cabrera, María; Cabrera-Domínguez, José; Torres-Lagares, Daniel; Machuca-Portillo, Guillermo
2017-01-01
Background Paranoid schizophrenia is a mental illness that involves no observable anatomical alteration. Main characteristic affects the personality of the individual, as well as areas of his own psychology. Case Report A 33-year-old man with paranoid schizophrenia and obsessive-compulsive disorder in treatment with Haloperidol, Oxcarbazepine, Olanzapine and Seroquel is presented. Dental exploration showed widespread decay mostly cervical with numerous root fragments, agenesis of lateral incisors, impacted wisdom teeth, missing teeth and malocclusion. Treatment plan included restoration of teeth decay, extractions of root fragments and implant-supported prostheses in bilateral upper lateral incisors for aesthetics reason. A previous consultation with a psychiatric specialist was performed and no contraindication were observed. A preliminary radiological examination was performed previous dental treatment and implant placement. Due to patient refusal to replace dental abscenses with implants, inform consent was signed up from his parents. After local anesthesia, first implant was placed at upper right lateral positions (Straumann Bone Level Ø 3.3 mm, length 10 mm). Two weeks later a second implant was placed at upper left lateral position (Straumann Bone Level Ø 3.3 mm, length 12 mm). The patient showed no postoperative complications. After implant placement, the patient attended scheduled review appointments. The prosthesis was placed after a 3-month period of osseointegration. Conclusions Implant placement can be considered a suitable option for people with mental disorders. A previous consultation with psychiatric specialists for conducting a good patient management is necessaire. Key words:Paranoid schizophrenia, obsessive-compulsive disorder, dental implants. PMID:29302292
Elbow arthroscopy: setup, portal placement, and simple procedures.
Ahmad, Christopher S; Vitale, Mark A
2011-01-01
Elbow arthroscopy has become an accepted treatment for numerous elbow conditions, including loose bodies, lateral epicondylitis, contractures, painful osteophytes, synovitis, osteochondritis dissecans, synovial plica, and osteoarthritis. It is absolutely necessary that the treating surgeon have complete knowledge of elbow anatomy. Three options exist for patient positioning: supine, prone, and lateral decubitus. Standard arthroscopic probes, grasping forceps, punches, and motorized shavers and burrs are used in the procedure. Retractors are essential for visualizing, exposing, and protecting nerves. Specially designed capsular biters can be used to develop a plane between the capsule and the surrounding soft tissues to facilitate capsulotomy and capsulectomy. Among elbow arthroscopists, the sequence of portal placement varies; however, there is little variation in the exact location of portal placement because of neurovascular constraints. Loose body removal and extensor carpi radialis brevis release for lateral epicondylitis are common procedures suitable for the beginning arthroscopist. For beginning and advanced procedures, the surgeon's skill and competence must be at a level consistent with the procedure to avoid complications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wachsman, A.M., E-mail: ariw@fusemail.com; Hoffer, E.K.; Forauer, A.R.
A case of tension pneumothorax developed after placement of a tunneled pleural catheter for treatment of malignant pleural effusion in a patient with advanced lung cancer. The catheter placement was carried out by an experienced operator under direct ultrasound guidance, and the patient showed immediate symptomatic improvement with acute decompensation occurring several hours later. Possible mechanisms for this serious complication of tunneled pleural catheter placement are described, and potential strategies to avoid or prevent it in future are discussed.
Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement.
Blagg, Stuart E; Don, Angus S; Robertson, Peter A
2009-06-01
Anatomic study of C1 osteology using computerized tomography. To define the anatomy of the C1 lateral mass and make recommendations for optimal entry point and screw placement at C1. C1 lateral mass screw fixation is a reliable biomechanical technique that gives equivalent stability to that of Magerl transarticular screw fixation combined with posterior wiring for C1-C2 fusion. Use of a lateral mass screw allows alternative stabilization constructs to the transarticular technique when C2 vertebral artery anatomy is unfavorable. Because the vertebral artery travels lateral to the lateral mass, then crosses medially over the C1 neural arch, it is at risk during instrumentation. Medially, the cord and canal contents are at risk. While the anatomy of the C1 vertebra and lateral mass is well known, specific definition of ideal entry points, screw pathway direction, and dimensions of screws requires further clarification to enable a clinically safe surgical technique. Fifty consecutive patients underwent computerized tomography scans of their cervical spine. Using calibrated scans, measurements were taken to give the average dimensions of the C1 vertebra with a view for insertion of lateral mass screws beneath the posterior arch. The range of anatomic dimensions was examined to assess risk of vertebral artery damage in this population. The average length of screw within the lateral mass is 17.9 mm with 21.5 mm of screw posterior to the lateral mass, necessary to allow rod placement posteriorly. The safest entry point was directly beneath the medial edge of the posterior arch/lamina where it joins the lateral mass. The ideal direction of screw angulation in the sagittal plane was parallel to the posterior arch of C1. In the medial lateral plane, direct anterior placement could be used, but the lateral mass will tolerate 20 degrees of medial angulation from this starting point. The average distance between the vertebral artery foramen laterally and the screw pathway was 8.8 mm using these landmarks, and 5.8 mm from the medial aspect of the lateral mass. The range of anatomic variation was such that 9 lateral masses had a vertebral artery foramen to screw distance of only 3 mm. The vertebral artery was not at risk when these anatomic landmarks were used. C1 lateral mass screws are best placed beneath the posterior arch, parallel with the arch in the sagittal plan. The entry point is the medial border of the neural arch at its junction with the lateral mass. Straight ahead screw direction is safe in the axial plane, but up to 20 degrees of medial angulation will increase the safety margin from the vertebral artery foramen, and this technique avoids vertebral artery damage and optimizes lateral mass screw purchase. We suggest that this is the preferred method of entry into the lateral mass of C1.
Juodzbalys, Gintaras
2015-01-01
ABSTRACT Objectives The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN) repositioning with a minimum 6 months of follow-up. Results A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments. PMID:25937873
Medial compressible forefoot sole elements reduce ankle inversion in lateral SSC jumps.
Fleischmann, Jana; Mornieux, Guillaume; Gehring, Dominic; Gollhofer, Albert
2013-06-01
Sideward movements are associated with high incidences of lateral ankle sprains. Special shoe constructions might be able to reduce these injuries during lateral movements. The purpose of this study was to investigate whether medial compressible forefoot sole elements can reduce ankle inversion in a reactive lateral movement, and to evaluate those elements' influence on neuromuscular and mechanical adjustments in lower extremities. Foot placement and frontal plane ankle joint kinematics and kinetics were analyzed by 3-dimensional motion analysis. Electromyographic data of triceps surae, peroneus longus, and tibialis anterior were collected. This modified shoe reduced ankle inversion in comparison with a shoe with a standard sole construction. No differences in ankle inversion moments were found. With the modified shoe, foot placement occurred more internally rotated, and muscle activity of the lateral shank muscles was reduced. Hence, lateral ankle joint stability during reactive sideward movements can be improved by these compressible elements, and therefore lower lateral shank muscle activity is required. As those elements limit inversion, the strategy to control inversion angles via a high external foot rotation does not need to be used.
Urban, Istvan; Jovanovic, Sascha A; Buser, Daniel; Bornstein, Michael M
2015-01-01
The objective of this study was to assess implant therapy after a staged guided bone regeneration procedure in the anterior maxilla by lateralization of the nasopalatine nerve and vessel bundle. Neurosensory function following augmentative procedures and implant placement, assessed using a standardized questionnaire and clinical examination, were the primary outcome variables measured. This retrospective study included patients with a bone defect in the anterior maxilla in need of horizontal and/or vertical ridge augmentation prior to dental implant placement. The surgical sites were allowed to heal for at least 6 months before placement of dental implants. All patients received fixed implant-supported restorations and entered into a tightly scheduled maintenance program. In addition to the maintenance program, patients were recalled for a clinical examination and to fill out a questionnaire to assess any changes in the neurosensory function of the nasopalatine nerve at least 6 months after function. Twenty patients were included in the study from February 2001 to December 2010. They received a total of 51 implants after augmentation of the alveolar crest and lateralization of the nasopalatine nerve. The follow-up examination for questionnaire and neurosensory assessment was scheduled after a mean period of 4.18 years of function. None of the patients examined reported any pain, they did not have less or an altered sensation, and they did not experience a "foreign body" feeling in the area of surgery. Overall, 6 patients out of 20 (30%) showed palatal sensibility alterations of the soft tissues in the region of the maxillary canines and incisors resulting in a risk for a neurosensory change of 0.45 mucosal teeth regions per patient after ridge augmentation with lateralization of the nasopalatine nerve. Regeneration of bone defects in the anterior maxilla by horizontal and/or vertical ridge augmentation and lateralization of the nasopalatine nerve prior to dental implant placement is a predictable surgical technique. Whether or not there were clinically measurable impairments of neurosensory function, the patients did not report them or were not bothered by them.
Pedicle screw placement in patients with variant atlas pedicle.
Zhang, Qiang-Hua; Li, Hai-Dong; Min, Ji-Kang
2016-08-01
To investigate how the anatomy of variant atlas vertebra impacts on the strategy used to place pedicle screws used to treat atlantoaxial instability. The study enrolled patients with cervical instability who had a posterior arch pedicle height <3.5 mm at the anchor point, a vertebral artery groove height <3.5 mm, or both. Pedicle screws were fitted according to the anatomy of the variant atlas vertebra. Patients were followed-up to evaluate accuracy of the screw placement and maintenance of cervical stability. A total of 28 patients were enrolled. The mean height of the atlas pedicle proximal section was >5.0 mm. For the vertebral artery groove, the height of the lateral region was significantly greater than that of the medial region. Approximately 60% of atlas vertebrae had lateral heights >3.5 mm (34 of 56). The majority of the posterior arch heights were <3.0 mm. There were no perioperative or postoperative complications observed. Pedicle screw placement in the lateral pedicle region is the safest and most reliable strategy to treat variant atlas pedicles. © The Author(s) 2016.
Stabilization of a three-dimensional limit cycle walking model through step-to-step ankle control.
Kim, Myunghee; Collins, Steven H
2013-06-01
Unilateral, below-knee amputation is associated with an increased risk of falls, which may be partially related to a loss of active ankle control. If ankle control can contribute significantly to maintaining balance, even in the presence of active foot placement, this might provide an opportunity to improve balance using robotic ankle-foot prostheses. We investigated ankle- and hip-based walking stabilization methods in a three-dimensional model of human gait that included ankle plantarflexion, ankle inversion-eversion, hip flexion-extension, and hip ad/abduction. We generated discrete feedback control laws (linear quadratic regulators) that altered nominal actuation parameters once per step. We used ankle push-off, lateral ankle stiffness and damping, fore-aft foot placement, lateral foot placement, or all of these as control inputs. We modeled environmental disturbances as random, bounded, unexpected changes in floor height, and defined balance performance as the maximum allowable disturbance value for which the model walked 500 steps without falling. Nominal walking motions were unstable, but were stabilized by all of the step-to-step control laws we tested. Surprisingly, step-by-step modulation of ankle push-off alone led to better balance performance (3.2% leg length) than lateral foot placement (1.2% leg length) for these control laws. These results suggest that appropriate control of robotic ankle-foot prosthesis push-off could make balancing during walking easier for individuals with amputation.
PBF Reactor Building (PER620). Camera faces southeast. Concrete placement will ...
PBF Reactor Building (PER-620). Camera faces southeast. Concrete placement will leave opening for neutron camera to be installed later. Note vertical piping within rebar. Photographer: John Capek. Date: July 6, 1967. INEEL negative no. 67-3514 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
Czell, David; Bauer, Matthias; Binek, Janek; Schoch, Otto D; Weber, Markus
2013-05-01
Percutaneous endoscopic gastrostomy (PEG) tube placement in amyotrophic lateral sclerosis (ALS) patients with impaired respiratory function is associated with an increased risk of peri-procedural and post-interventional complications. It was the aim of the study to analyze peri- and post-interventional complications and survival after PEG tube placement under noninvasive ventilation (NIV) in ALS patients with various degrees of respiratory impairment. Twenty-six subjects were included in this retrospective case study. Prior to PEG tube placement, training with ventilatory support via an oronasal mask was performed with ALS subjects on the pneumology ward. PEG placement was then performed under continuous NIV. FVC, sniff nasal inspiratory pressure, and demographic data were assessed. Complication rates and 1-month and overall survival rates were analyzed. There were no deaths within 24 hours after PEG placement. One subject died within the first month. The mean survival rate after PEG was 12 ± 10 months (range 0.6-42 months). There was no difference in post-PEG survival between subjects with moderately (> 50%) and severely (< 50%) impaired FVC. In this case series, PEG tube insertion was associated with minimal peri- and post-procedural complications. The low complication rate might be due to the systematic use of procedural NIV in ALS subjects.
Orthodontic management of congenitally missing maxillary lateral incisors: a case report.
Paduano, Sergio; Cioffi, Iacopo; Rongo, Roberto; Cupo, Antonello; Bucci, Rosaria; Valletta, Rosa
2014-01-01
This case report describes the orthodontic treatment of a woman, aged 15 years, with permanent dentition, brachyfacial typology, with congenitally missing maxillary lateral incisors. Multibracket straightwire fixed appliance was used to open the space for dental implant placement, and treat the impaired occlusion. The missing lateral incisors were substituted with oral implants.
Kocadal, Onur; Yüksel, Korcan; Güven, Melih
2018-01-27
The two-tunnel coracoclavicular ligament reconstruction (CLR) technique is one of the treatment approaches commonly used in the surgical treatment of acromioclavicular (AC) injuries. Clavicular tunnel malposition is one of the major causes of failure in coracoclavicular ligament reconstruction. The main purpose of this study was to investigate the effects of clavicular tunnel placement on tendon loading in the CLR technique with finite element analysis. Models of clavicle and scapula were constructed using computerized tomography images. Two clavicular bone tunnel reconstruction models were created with the tendon passing through the conoid and trapezoid tunnels. Four models based on the tunnel ratio (TR) method and defined as primary, anatomic, medialized, and lateralized were constructed to evaluate the effect of tunnel placement on loading conditions during tendon graft. All models were loaded by insertion from the trapezius and sternocleidomastoid muscles. The loading on the tendon were evaluated with the finite element analysis. The highest load value measured on the tendon was in the anatomic model (0.789 kPa), and the lowest load value (0.598 kPa) was measured in the lateralized tunnel model. The load value of the primary model was (0.657 kPa), and the medialized model's value was (0.752 kPa). In two-tunnel CLR technique, tendon loadings are related to tunnel placement. Medialized tunnel placement increases tendon loading. The TR method may be an appropriate option for determining tunnel placement.
Numerical analysis of dense narrow backfills for increasing lateral passive resistance.
DOT National Transportation Integrated Search
2010-08-01
Previously, full-scale lateral load tests conducted on pile caps with different aspect ratios showed that placement : of a narrow, dense backfill zone against the cap could substantially increase the passive resistance. The objective : of this study ...
Orthodontic Management of Congenitally Missing Maxillary Lateral Incisors: A Case Report
Rongo, Roberto; Cupo, Antonello; Valletta, Rosa
2014-01-01
This case report describes the orthodontic treatment of a woman, aged 15 years, with permanent dentition, brachyfacial typology, with congenitally missing maxillary lateral incisors. Multibracket straightwire fixed appliance was used to open the space for dental implant placement, and treat the impaired occlusion. The missing lateral incisors were substituted with oral implants. PMID:24711929
Linares, L Oriana; Li, MiMin; Shrout, Patrick E; Brody, Gene H; Pettit, Gregory S
2007-12-01
Sibling unity during family transitions is considered a protective factor for child behavior problems, but there is little empirical support for the widespread child protection policy of placing siblings together in foster care. In a prospective study of 156 maltreated children, siblings were classified in 1 of 3 placement groups: continuously together (n = 110), continuously apart (n = 22), and disrupted placement (siblings placed together were separated; n = 24). Changes in child adjustment as a function of sibling relationship and placement group were examined. Sibling positivity predicted lower child problems at follow-up (about 14 months later), while sibling negativity predicted higher child problems. Placement group did not affect child behavior problems at follow-up; however, compared to siblings in continuous placement (either together or apart), siblings in disrupted placement with high initial behavior problems were rated as having fewer problems at follow-up, while siblings in disrupted placement with low initial behavior problems were rated as having more problems at follow-up. These findings highlight the importance of considering relationships between siblings and the risk that one poses to another before early placement decisions are made.
Delayed Implants Outcome in Maxillary Molar Region.
Crespi, Roberto; Capparè, Paolo; Crespi, Giovanni; Gastaldi, Giorgio; Gherlone, Enrico F
2017-04-01
The aim of the present study was to assess bone volume changes in maxillary molar regions after delayed implants placement. Patients presented large bone defects after tooth extractions. Reactive soft tissue was left into the defects. No grafts were used. Cone beam computed tomography (CBCT) scans were performed before tooth extractions, at implant placement (at 3 months from extraction) and 3 years after implant placement, bone volume measurements were assessed. Bucco-lingual width showed a statistically significant decrease (p = .013) at implant placement, 3 months after extraction. Moreover, a statistically significant increase (p < .01) was measured 3 years after implant placement. No statistically significant differences (p > .05) were found between baseline values (before extraction) and at 3 years from implant placement. Vertical dimension showed no statistically significant differences (p > .05) at implant placement, 3 months after extraction. Statistically significant differences (p < .0001) were found between baseline values (before extraction) and at 3 months from implant placement as well as between implant placement values and 3 years later. CT scans presented successful outcome of delayed implants placed in large bone defects at 3-year follow-up. © 2016 Wiley Periodicals, Inc.
Embryonic development of connections in turtle pallium.
Cordery, P; Molnár, Z
1999-10-11
We are interested in similarities and conserved mechanisms in early development of the reptilian and mammalian thalamocortical connections. We set out to analyse connectivity in embryonic turtle brains (Pseudemys scripta elegans, between stages 17 and 25), by using carbocyanine dye tracing. From the earliest stages studied, labelling from dorsal and ventral thalamus revealed backlabelled cells among developing thalamic fibres within the lateral forebrain bundle and striatum, which had similar morphology to backlabelled internal capsule cells in embryonic rat (Molnár and Cordery, 1999). However, thalamic crystal placements did not label cells in the dorsal ventricular ridge (DVR) at any stage examined. Crystal placements into both dorsal and lateral cortex labelled cells in the DVR and, reciprocally, DVR crystal placements labelled cells in the dorsal and lateral cortices. Retrograde labelling revealed that thalamic fibres arrive in the DVR and dorsal cortex by stage 19. The DVR received projections from the nucleus rotundus and the dorsal cortex exclusively from the perirotundal complex (including lateral geniculate nucleus). Thalamic fibres show this remarkable degree of specificity from the earliest stage we could examine with selective retrograde labelling (stage 19). Our study demonstrates that axons of similar cells are among the first to reach dorsal and ventral thalamus in mammals and reptiles. Our connectional analysis in turtle suggests that some cells of the mammalian primitive internal capsule are homologous to a cell group within the reptilian lateral forebrain bundle and striatum and that diverse vertebrate brains might use a highly conserved pattern of early thalamocortical development. Copyright 1999 Wiley-Liss, Inc.
Abayev, Boris; Juodzbalys, Gintaras
2015-01-01
This article, the second in a two-part series, continues the discussion of inferior alveolar nerve lateralization/transposition for dental implant placement. The aim of this article is to review the scientific literature and clinical reports in order to analyse the neurosensory complications, risks and disadvantages of lateralization/transposition of the inferior alveolar nerve followed by implant placement in an edentulous atrophic posterior mandible. A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC databases, as well as academic sites and books. The articles were searched from January 1997 to July 2014. Articles in English language, which included adult patients between 18 - 80 years of age who had minimal residual bone above the mandibular canal and had undergone inferior alveolar nerve (IAN) repositioning, with minimum 6 months of follow-up, were included. A total of 21 studies were included in this review. Ten were related to IAN transposition, 7 to IAN lateralization and 4 to both transposition and lateralization. The IAN neurosensory disturbance function was present in most patients (99.47% [376/378]) for 1 to 6 months. In total, 0.53% (2/378) of procedures the disturbances were permanent. Inferior alveolar nerve repositioning is related to initial transient change in sensation in the majority of cases. The most popular causes of nerve damage are spatula-caused traction in the mucoperiosteal flap, pressure due to severe inflammation or retention of fluid around the nerve and subsequent development of transient ischemia, and mandibular body fracture.
Smith, Jacob D; Jack, Megan M; Harn, Nicholas R; Bertsch, Judson R; Arnold, Paul M
2016-06-01
Study Design Case series of seven patients. Objective C2 stabilization can be challenging due to the complex anatomy of the upper cervical vertebrae. We describe seven cases of C1-C2 fusion using intraoperative navigation to aid in the screw placement at the atlantoaxial (C1-C2) junction. Methods Between 2011 and 2014, seven patients underwent posterior atlantoaxial fusion using intraoperative frameless stereotactic O-arm Surgical Imaging and StealthStation Surgical Navigation System (Medtronic, Inc., Minneapolis, Minnesota, United States). Outcome measures included screw accuracy, neurologic status, radiation dosing, and surgical complications. Results Four patients had fusion at C1-C2 only, and in the remaining three, fixation extended down to C3 due to anatomical considerations for screw placement recognized on intraoperative imaging. Out of 30 screws placed, all demonstrated minimal divergence from desired placement in either C1 lateral mass, C2 pedicle, or C3 lateral mass. No neurovascular compromise was seen following the use of intraoperative guided screw placement. The average radiation dosing due to intraoperative imaging was 39.0 mGy. All patients were followed for a minimum of 12 months. All patients went on to solid fusion. Conclusion C1-C2 fusion using computed tomography-guided navigation is a safe and effective way to treat atlantoaxial instability. Intraoperative neuronavigation allows for high accuracy of screw placement, limits complications by sparing injury to the critical structures in the upper cervical spine, and can help surgeons make intraoperative decisions regarding complex pathology.
Blizzard, Daniel J; Thomas, J Alex
2018-03-15
Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with intraoperative repositioning and may lead to significant improvements in operative efficiency and cost savings. 4.
Fee, L
2017-04-21
Socket preservation maintains bone volume post-extraction in anticipation of an implant placement or fixed partial denture pontic site. This procedure helps compensate for the resorption of the facial bone wall. Socket preservation should be considered when implant placement needs to be delayed for patient or site-related reasons. The ideal healing time before implant placement is six months. Socket preservation can reduce the need for later bone augmentation. By reducing bone resorption and accelerating bone formation it increases implant success and survival. Biomaterials for socket grafting including autograft, allograft, xenograft and alloplast. A bone substitute with a low substitution rate is recommended.
Schwarz, Frank; Mihatovic, Ilja; Ghanaati, Shahram; Becker, Jürgen
2017-08-01
To assess the clinical safety and performance of collagenated xenogeneic bone block (CXBB) for lateral alveolar ridge augmentation and two-stage implant placement. In ten patients exhibiting a single-tooth gap, the surgical procedure included the preparation of mucoperiosteal flaps, a rigid fixation of CXBB (Geistlich Bio-Graft ® ) using an osteosynthesis screw, and contour augmentation. After 24 weeks of submerged healing, the primary endpoint was defined as the final ridge width sufficient to place an adequately dimensioned titanium implant at the respective sites. Secondary outcomes included, for example, the gain in ridge width (mm). Clinical parameters (e.g., bleeding on probing - BOP, probing depth - PD, mucosal recession - MR) were assessed immediately after the cementation of the crown and at the final visit. At 24 weeks, implant placement could be achieved in 8 of 10 patients exhibiting a mean gain in ridge width (mean ± SD) of 3.88 ± 1.75 mm. Histological analysis has pointed to a homogeneous osseous organization of CXBB. The changes of mean BOP, PD, and MR values at the final visit amounted to 16.62 ± 32.02%, 0.04 ± 0.21 mm, and -0.04 ± 0.12 mm, respectively. CXBB may be successfully used to support lateral alveolar ridge augmentation and two-stage implant placement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Molina, Ana; Sanz-Sánchez, Ignacio; Martín, Conchita; Blanco, Juan; Sanz, Mariano
2017-04-01
To compare the effect of placing the definitive abutment at the time of implant placement versus at a later stage, on the soft and hard tissue changes around dental implants. Platform-switched implants were placed in the posterior maxilla or mandible of partial edentulous patients and they were randomized to receive the definitive abutment at the moment of implant placement, or 6-12 weeks later. Final prostheses were delivered 2-4 weeks later. Radiographic assessment of vertical bone level changes (primary outcome), clinical status of peri-implant tissues, changes in soft tissues margin, papilla filling, patient-related outcomes and adverse events were assessed 6 and 12 months after loading. 60 implants were placed in 40 patients, replacing single or multiple absent teeth. One implant was lost 1 week after insertion (overall survival rate: 98.3%). A statistically significant greater bone resorption from surgery to 6 months post-loading was observed for those implants subjected to abutment change (control group: -1.24 ± 0.79 mm; test group: -0.61 ± 0.40 mm; P = 0.028). Periodontal clinical parameters and patient-related outcomes, however, did not demonstrate significant differences between groups at any time point. A significant increase in papilla height was observed from loading to 12 months in all implants (control group: 1.17 ± 1.47 mm; test group: 0.98 ± 0.89 mm) and a slight but not significant coronal migration of the gingival margin. The connection and disconnection of healing abutments is associated with significantly increased bone loss during the healing period between implant placement and 6 months post-loading, when compared to one-time abutment placement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Walker, David R; Kinney, Allison L; Wright, Thomas W; Banks, Scott A
2016-06-01
Reverse total shoulder arthroplasty commonly treats cuff-deficient or osteoarthritic shoulders not amenable to rotator cuff repair. This study investigates deltoid moment arm sensitivity to variations in the joint center and humeral offset of 3 representative reverse total shoulder arthroplasty subjects. We hypothesized that a superior joint implant placement may exist, indicated by muscle moment arms, compared with the current actual surgical implant configuration. Moment arms for the anterior, lateral, and posterior aspects of the deltoid muscle were determined for 1521 perturbations of the humeral offset location away from the surgical placement in a subject-specific musculoskeletal model with motion defined by subject-specific in vivo abduction kinematics. The humeral offset was varied from its surgical position ±4 mm in the anterior/posterior direction, ±12 mm in the medial/lateral direction, and -10 to 14 mm in the superior/inferior direction. The anterior deltoid moment arm varied in humeral offset and center of rotation up to 20 mm, primarily in the medial/lateral and superior/inferior directions. The lateral deltoid moment arm varied in humeral offset up to 20 mm, primarily in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15 mm, primarily in early abduction, and was most sensitive to humeral offset changes in the superior/inferior direction. High variations in muscle moment arms were found for all 3 deltoid components, presenting an opportunity to dramatically change the deltoid moment arms through surgical placement of the reverse shoulder components and by varying the overall offset of the humerus. Basic Science Study; Computer Modeling. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Turner, Michael S; Nguyen, Ha Son; Payner, Troy D; Cohen-Gadol, Aaron A
2011-07-01
Posterior fossa cysts are usually divided into Dandy-Walker malformations, arachnoid cysts, and isolated and/or trapped fourth ventricles. Shunt placement is a mainstay treatment for decompression of these fluid collections when their expansion becomes symptomatic. Although several techniques to drain symptomatic posterior fossa cysts have been described, each method carries its own advantages and disadvantages. This article describes an alternative technique. In 10 patients, the authors used an alternative technique involving stereotactic and endoscopic methods to place a catheter in symptomatic posterior fossa cysts across the tentorium. Discussion of these cases is included, along with a review of various approaches to shunt placement in this region and recommendations regarding the proposed technique. No patient suffered intracranial hemorrhage related to the procedure and catheter implantation. All 3 patients who underwent placement of a new transtentorial cystoperitoneal shunt and a new ventriculoperitoneal shunt did not suffer any postoperative complication; a decrease in the size of their posterior fossa cysts was evident on CT scans obtained during the 1st postoperative day. Follow-up CT scans demonstrated either stable findings or further interval decrease in the size of their cysts. In 1 patient, the postoperative head CT demonstrated that the transtentorial catheter terminated posterior to the right parietal occipital region without entering the retrocerebellar cyst. This patient underwent a repeat operation for proximal shunt revision, resulting in an acceptable catheter implantation. The patient in Case 8 suffered from a shunt infection and subsequently underwent hardware removal and aqueductoplasty with stent placement. The patient in Case 9 demonstrated a slight increase in fourth ventricle size and was returned to the operating room. Exploration revealed a kink in the tubing connecting the distal limb of the Y connector to the valve. The Y connector was replaced with a T connector, and 1 week later, CT scans exhibited interval decompression of the ventricles. This patient later presented with cranial wound breakdown and an exposed shunt. His shunt hardware was removed and he was treated with antibiotics. He later underwent reimplantation of a lateral ventricular and transtentorial shunt and suffered no other complications during a 3-year follow-up period. The introduction of endoscopic and stereotactic techniques has expanded the available treatment possibilities for posterior fossa cysts.
Gardner, Aimee K; Abdelfattah, Kareem; Wiersch, John; Ahmed, Rami A; Willis, Ross E
2015-01-01
Error management training is an approach that encourages exposure to errors during initial skill acquisition so that learners can be equipped with important error identification, management, and metacognitive skills. The purpose of this study was to determine how an error-focused training program affected performance, retention, and transfer of central venous catheter (CVC) placement skills when compared with traditional training methodologies. Surgical interns (N = 30) participated in a 1-hour session featuring an instructional video and practice performing internal jugular (IJ) and subclavian (SC) CVC placement with guided instruction. All interns underwent baseline knowledge and skill assessment for IJ and SC (pretest) CVC placement; watched a "correct-only" (CO) or "correct + error" (CE) instructional video; practiced for 30 minutes; and were posttested on knowledge and IJ and SC CVC placement. Skill retention and transfer (femoral CVC placement) were assessed 30 days later. All skills tests (pretest, posttest, and transfer) were videorecorded and deidentified for evaluation by a single blinded instructor using a validated 17-item checklist. Both the groups exhibited significant improvements (p < 0.001) in knowledge and skills after the 1-hour training program, but the increase of items achieved on the performance checklist did not differ between conditions (CO: IJ Δ = 35%, SC Δ = 29%; CE: IJ Δ = 36%, subclavian Δ = 33%). However, 1 month later, the CO group exhibited significant declines in skill retention on IJ CVC placement (from 68% at posttraining to 44% at day 30; p < 0.05) and SC CVC placement (from 63% at posttraining to 49% at day 30; p < 0.05), whereas the CE group did not have significant decreases in performance. The CE group performed significantly better on femoral CVC placement (i.e., transfer task; 62% vs 38%; p < 0.01) and on 2 of the 3 complication scenarios (p < 0.05) when compared with the CO group. These data indicate that incorporating error-based activities and discussions into training programs can be beneficial for skill retention and transfer. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Cadaveric validation of dry needle placement in the lateral pterygoid muscle.
Mesa-Jiménez, Juan A; Sánchez-Gutiérrez, Jesús; de-la-Hoz-Aizpurua, José L; Fernández-de-las-Peñas, César
2015-02-01
The aim of this anatomical study was to determine if a needle is able to reach the lateral pterygoid muscle during the application of dry needling technique. A dry needling approach using 2 needles of 50 to 60 mm in length, one inserted over the zygomatic process posterior at the obituary arch (for the superior head) and other inserted below the zygomatic process between the mandibular condyle and the coronoid process (for the inferior head), was proposed. A progressive dissection into 3 stages was conducted into 2 heads of fresh male cadavers. First, dry needling of the lateral pterygoid muscle was applied on the cadaver. Second, a block dissection containing the lateral pterygoid was harvested. Finally, the ramus of the mandible was sectioned by osteotomy to visualize the lateral pterygoid muscle with the needle placements. With the needles inserted into the cadaver, the block dissection revealed that the superior needle reached the superior (sphenoid) head of the lateral pterygoid muscle and the inferior needle reached the inferior (pterygoid) head of the muscle. At the final stage of the dissection, when the ramus of the mandible was sectioned by osteotomy, it was revealed that the superior needle entered into the belly of the superior head of the lateral pterygoid muscle. This anatomical study supports that dry needling technique for the lateral pterygoid muscle can be properly conducted with the proposed approach. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Canfora, Alfonso; Mauriello, Claudio; Ferronetti, Antonio; Marte, Gianpaolo; Di Maio, Vittorio; Ciorra, Guido; Esposito, Maria Grazia; Giuliano, Maria Elena; Fregola, Giovanni; Barra, Luigi; Cuzzovaglia, Salvatore; Bottino, Vincenzo; Maida, Pietro
2017-02-01
Ultrasound-guidance has become the routine method for internal jugular vein (IJV) catheterization reducing dramatically failure and complication rates for central venous port (CVP) placement. The aim of this study was to determine the safety and efficacy of ultrasound-guided IJV CVP placement in elderly oncologic patients. Between January 2013 and December 2015, 101 elderly oncological patients underwent right IJV CVP placement under ultrasound-guidance. The length of catheter introduction ranged from 18 to 21 cm. Intraoperative fluoroscopy (IF) was always performed intraoperatively. Chest X-ray (CXR) was always performed 30 min after the end of the procedure. The morbidity rate was 1.98%; two arterial punctures were reported with one self-limiting hematoma. Two patients (1.98%) had catheter misplacements, recognized by intraoperative IF. No patients (0%) experienced pneumothorax (PNX), confirmed at CXR. Patients were all discharged at maximum 6 h from the procedure. The risk of catheter misplacement, PNX, and arterial/nerve puncture remains present with this technique. Lower rates of catheter misplacement have been reported after right IJV puncture, probably for its straight vertical course. Our results are in accordance with literature (1 counter-lateral subclavian vein and 1 counter-lateral internal jugular vein misplacements). All misplacements were detected intraoperatively. The PNX rates after cannulation of the IJV vary between 0.0 and 0.5%. We had no PNX occurrence. Ultrasonography (US) has improved safety and effectiveness of port system placements. While routine post-procedural CXR seems avoidable, IF should be considered mandatory.
Behavior problems and placement change in a national child welfare sample: a prospective study.
Aarons, Gregory A; James, Sigrid; Monn, Amy R; Raghavan, Ramesh; Wells, Rebecca S; Leslie, Laurel K
2010-01-01
There is ongoing debate regarding the impact of youth behavior problems on placement change in child welfare compared to the impact of placement change on behavior problems. Existing studies provide support for both perspectives. The purpose of this study was to prospectively examine the relations of behavior problems and placement change in a nationally representative sample of youths in the National Survey of Child and Adolescent Well-Being. The sample consisted of 500 youths in the child welfare system with out-of-home placements over the course of the National Survey of Child and Adolescent Well-Being study. We used a prospective cross-lag design and path analysis to examine reciprocal effects of behavior problems and placement change, testing an overall model and models examining effects of age and gender. In the overall model, out of a total of eight path coefficients, behavior problems significantly predicted placement changes for three paths and placement change predicted behavior problems for one path. Internalizing and externalizing behavior problems at baseline predicted placement change between baseline and 18 months. Behavior problems at an older age and externalizing behavior at 18 months appear to confer an increased risk of placement change. Of note, among female subjects, placement changes later in the study predicted subsequent internalizing and externalizing behavior problems. In keeping with recommendations from a number of professional bodies, we suggest that initial and ongoing screening for internalizing and externalizing behavior problems be instituted as part of standard practice for youths entering or transitioning in the child welfare system.
Self-expanding metallic stents drainage for acute proximal colon obstruction
Yao, Li-Qin; Zhong, Yun-Shi; Xu, Mei-Dong; Xu, Jian-Min; Zhou, Ping-Hong; Cai, Xian-Li
2011-01-01
AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery. METHODS: Eighty-one colon (proximal to spleen flex) carcinoma patients (47 males and 34 females, aged 18-94 years, mean = 66.2 years) treated between September 2004 and June 2010 for acute colon obstruction were enrolled to this study, and their clinical and radiological features were reviewed. After a cleaning enema was administered, urgent colonoscopy was performed. Subsequently, endoscopic decompression using SEMS placement was attempted. RESULTS: Endoscopic decompression using SEMS placement was technically successful in 78 (96.3%) of 81 patients. Three patients’ symptoms could not be relieved after SEMS placement and emergent operation was performed 1 d later. The site of obstruction was transverse colon in 18 patients, the hepatic flex in 42, and the ascending colon in 21. Following adequate cleansing of the colon, patients’ abdominal girth was decreased from 88 ± 3 cm before drainage to 72 ± 6 cm 7 d later, and one-stage surgery after 8 ± 1 d (range, 7-10 d) was performed. No anastomotic leakage or postoperative stenosis occurred after operation. CONCLUSION: SEMS placement is effective and safe in the management of acute proximal colon obstruction due to colon carcinoma, and is considered as a bridged method before curative surgery. PMID:21876623
Avoiding Pitfalls of Tibiotalocalcaneal Nail Malposition With Internal Rotation Axial Heel View.
Callahan, Ryan; Juliano, Paul; Aydogan, Umur; Clayton, Justin
2018-04-01
Tibiotalocalcaneal (TTC) nails are often used for complex hind foot arthrodesis and deformity correction. The natural valgus alignment of the hindfoot creates a challenge to optimum placement of the guidewire and eventual nail with a straight or valgus-curved nail. Five fresh frozen cadavers were used for placement of a TTC guidewire with standard anterior-posterior (AP), lateral, and Harris axial heel views as a reference for proper placement. The limb was then rotated 15°, 30°, and 45° both internally and externally to evaluate the perceived amount of osseous purchase within the calcaneus. The TTC nail was then inserted and dissection was performed to demonstrate proximity of the nail to the sustentaculum tali and neurovascular structures. A 30° internal rotation Harris axial heel view demonstrated the most accurate representation of osseous purchase within the calcaneus with the guidewire and nail placement. When the guidewire was placed with standard imaging the nail was often ultimately placed in close proximity to the sustentaculum tali and neurovascular structures. Careful placement of the guidewire prior to reaming and nail placement should be undertaken to avoid neurovascular injury and to increase osseous purchase. For optimal guidewire placement, the authors suggest using appropriate anatomic landmarks and using a 30° internally rotated Harris axial heel view to verify correct placement. Level V: Expert opinion.
Mahesh, Bijjawara; Upendra, Bidre; Vijay, Sekharappa; Arun, Kumar; Srinivasa, Reddy
2017-03-01
More than half of the perforations reported with usage of cervical pedicle screws (CPS) are lateral perforations, endangering the vertebral artery. The medial cortical pedicle screw (MCPS) technique with partial drilling of the medial cortex shifts the trajectory of pedicle screws medially, decreasing the lateral perforations. To evaluate the decrease in lateral perforations of CPS with use of MCPS technique, in relation to medial angulation. Retrospective analysis and technical report of the MCPS technique and its safety. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. Axial reconstructed computed tomography (CT) scan images of the inserted screws were evaluated for placement, perforations, and transverse plane angulations using the Surgimap software (Surgimap Spine 1.1.2.271 Intl. 2009 Nemaris LLC). The angulations of screws were analyzed by the type and level of placement through unpaired t test and analysis of variance test. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. There were 49 males and 9 females. Thirty-seven patients had cervical trauma, 17 had cervical spondylotic myelopathy, two had tumors, and two had ankylosing spondylitis. The average age was 49 years (range 18 to 80 years). The screws were inserted using the MCPS technique. All patients underwent postoperative CT scans with GE Optima CT540 16 slice CT scanner (GE Healthcare Chalfont St. Giles, Buckinghamshire, UK). Axial reconstructed images along the axis of the inserted screws were evaluated for placement and perforations. Further, all the screws were evaluated for transverse plane angulations using the Surgimap software. The angulations of screw were analyzed by the type and level of placement through unpaired t test and analysis of variance test. No funds were received by any of the authors for the purpose of the present study. A total of 324 screws were assessed with postoperative CT scans. Two hundred fifty-six were found to be placed within the pedicle and 68 (20.98%) screws were found to have perforations. Forty screws (12.34%) had grade I medial perforations, 14 screws (4.32%) had grade I lateral perforations, 10 screws (3.08%) had grade II medial perforations, and 4 screws (1.23%) had grade IIlateral perforations. The average angulation of the nonperforated screws (n=256) was 28.6° (43°-17°), that of laterally perforated screws was 20.33° (13°-24°), and that of the medially perforated screws was 34.94° (45°-20°). On statistical analysis with each series, the 99% CI range for the in-screw angles was 27.91° to 29.34°; for the laterally perforated screw series, it was 18.42° to 22.23°; and that for the medially perforated screw series was 32.97° to 36.9°. The MCPS technique represents a shift in the concept of placement of CPS from the cancellous core to the medial cortex, avoiding screw deflection laterally by the thick proximal medial cortex. The present study shows that the lateral perforations can be consistently avoided, with a medial angulation of more than 27.91°, which is the primary concern with the use of pedicle screws in lower cervical spine. Further, the MCPS technique reduces the lateral perforations at a lesser insertion angle, which is technically desirable. Copyright © 2016 Elsevier Inc. All rights reserved.
Volpe, Stefano; Lanza, Massimiliano; Verrocchi, Damiano; Sennerby, Lars
2013-02-01
Insufficient bone volume often hamper placement of dental implants in the posterior maxilla. The aim of the present clinical study was to evaluate retrospectively the clinical outcome of implant placement in the resorbed posterior maxilla using an osteotome technique without adding any grafting material. Twenty patients with 5 to 9 mm of residual alveolar bone height in the posterior maxilla received twenty-nine implants (Neoss Ltd., Harrogate, UK) using an osteotomy technique without bone grafts. Intraoral radiographs were taken before and after implant placement, at the time of loading and after 11 to 32 months of loading (mean 16.4 months), to evaluate bone formation below the sinus membrane and marginal bone loss. Implant stability measurements (Osstell(TM) , Gothenburg, Sweden) were performed after implant installation and at abutment connection 5 months later. All implants were installed with the prosthetic platform level with the bone crest. No implant was lost giving a survival rate of 100% after a mean follow-up time of 16.4 months. The average vertical bone height was 7.2 ± 1.5 mm at placement and 10.0 ± 1.0 mm after 11 to 32 months. The average increase of 2.8 ± 1.1 mm was statistically significant. There was a statistically significant improvement in implant stability from 70.7 ± 9.2 implant stability quotient (ISQ) at placement to 76.7 ± 5.7 ISQ at abutment connection, 5 months later. The mean marginal bone loss amounted to 0.7 ± 0.3 mm after 11 to 32 months of loading. It is concluded that the osteotome technique evaluated resulted in predictable intrasinus bone formation, firm implant stability, and good clinical outcomes as no implants were lost and minimal marginal bone loss was observed. © 2011 Wiley Periodicals, Inc.
Tudisco, Cosimo; Bisicchia, Salvatore
2012-08-01
Incorrect bone tunnel position, particularly on the femoral side, is a frequent cause of failed anterior cruciate ligament reconstruction. Several studies have reported that drilling the femoral tunnel through the anteromedial portal allows a more anatomical placement on the lateral femoral condyle and higher knee stability than does transtibial reconstruction.In the current study, the femoral tunnel was drilled with transtibial (n=6) and anteromedial (n=6) portal techniques in 12 cadaveric knees. With appropriate landmarks inserted into bone tunnels, the direction and length of the tunnels were determined on anteroposterior and lateral radiographs. Knee stability was evaluated with a KT1000 arthrometer (MEDmetric Corporation, San Diego, California) and pivot shift test, comparing the pre- and postoperative values of both techniques. Finally, all knees were dissected to enhance vision of the insertion of the reconstructed ligament. The anteromedial portal technique led to better placement of the femoral tunnel in the coronal and sagittal planes, with higher knee stability according to the pivot shift test but not the KT1000 arthrometer. Anatomical and clinical results reported in the literature on transtibial and anteromedial portal techniques are controversial, but most of studies report better results with the anteromedial portal technique, especially regarding rotational stability. The current cadaveric study showed that the anteromedial portal technique provided better tunnel placement on the lateral femoral condyle in the coronal and sagittal planes, with an improvement in the rotational stability of the knee. Copyright 2012, SLACK Incorporated.
Hosseinzadeh Nik, Tahereh; Shahsavari, Negin; Ghadirian, Hannaneh; Ostad, Seyed Nasser
2016-07-01
The aim of this randomized clinical study was to investigate the effectiveness of acetaminophen 650 mg or liquefied ibuprofen 400 mg in pain control of orthodontic patients during separation with an elastic separator. A total of 101 patients with specific inclusion criteria were divided randomly into three groups (acetaminophen, liquefied ibuprofen, and placebo). They were instructed to take their drugs one hour before separator placement and every six hours afterward (five doses in total). They recorded their discomfort on visual analog scales immediately after separator placement, 2 hours later, 6 hours later, at bedtime, and 24 hours after separator placement. Repeated measure analysis of variance (ANOVA) was used to compare the mean pain scores between the three groups. Data were collected from 89 patients. The pain increased with time in all groups. Pain scores were statistically lower in the analgesic groups compared with the placebo group (P.value<0.001), but no statistically significant difference was found in mean pain scores between the two drug groups (acetaminophen and liquefied ibuprofen) (P.value=1). Acetaminophen and liquefied ibuprofen have similar potential in pain reduction during separation.
Deen, H Gordon; Birch, Barry D; Wharen, Robert E; Reimer, Ronald
2003-01-01
Lateral mass plating has become the technique of choice for posterior cervical fixation. Although these systems are safe and reliable, they can be difficult to use in patients with abnormal cervical anatomy; screw placement can be compromised by the fixed hole spacing of the plate; screw back-out and other forms of implant failure can occur; and extension across the cervicothoracic junction can be problematic. To report a series of patients undergoing posterior cervical stabilization with a polyaxial screw-rod construct and to investigate whether this new system offers any advantages over existing methods of fixation. A prospective study evaluating clinical and radiographic parameters in a consecutive series of patients treated with this technique. There were 21 patients in the study group. The surgical indication was cervical spondylosis in 14, trauma in 2, postsurgical kyphosis in 2 and 1 case each of congenital cervicothoracic stenosis, C7-T1 pseudarthrosis and basilar invagination with brainstem compression. Clinical indicators included age, gender, neurologic status, surgical indication and number of levels stabilized. Note was made of whether laminectomy and concomitant anterior reconstructive surgery were performed. Radiographic indicators included early postoperative computed tomography (CT) scan to check for screw placement and plain radiographs at subsequent visits. The participants in this study underwent posterior cervical stabilization using lateral mass screw-rod fixation. Clinical and radiographic assessment was carried out immediately after surgery, and 3, 6 and 12 months after surgery. One-year follow-up was obtained in all cases. A total of 212 screws were implanted in 21 patients. Fixation was carried out over an average of 5.5 spinal segments (range, 2 to 11). The system was successfully implanted in all patients despite the presence of coronal and sagittal plane deformities and/or lateral mass abnormalities in the majority of cases. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-C7 lateral masses and upper thoracic pedicles. Early postoperative CT scanning confirmed satisfactory screw placement in all cases. Three patients experienced transient single-level radiculopathy, for an incidence of 1.4% per screw placed. Two patients developed wound seromas requiring evacuation. There were no infections or other wound healing problems. There were no examples of cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, loss of alignment or implant failure. When compared with plating techniques, screw-rod fixation appeared to offer several advantages. First, unlike plates, rods proved to be amenable to multiplanar contouring, which is often needed for deformities associated with cervical spondylosis. Second, lateral mass screw placement was more precise because it was not constrained by the hole spacing of the plate. Third, screw back-out and other types of implant failure were not seen. Fourth, the screw-rod system was more easily extended to the occiput and across the cervicothoracic junction. Fifth, the screw-rod system permitted the application of compression, distraction and reduction forces within the construct, to a greater extent than plate systems. The incidence of postoperative radiculopathy was similar to that seen with plate systems. These data indicate that posterior cervical stabilization with polyaxial screw-rod fixation is a safe, straightforward technique that appears to offer some advantages over existing methods of fixation. Results appear to be durable at 1-year follow-up. Benefits are more significant with longer constructs, especially those extending to the occiput or crossing the cervicothoracic junction.
Viljoen, Stephanus V; DeVries Watson, Nicole A; Grosland, Nicole M; Torner, James; Dalm, Brian; Hitchon, Patrick W
2014-10-01
The objective of this study was to evaluate the biomechanical properties of lateral instrumentation compared with short- and long-segment pedicle screw constructs following an L-1 corpectomy and reconstruction with an expandable cage. Eight human cadaveric T10-L4 spines underwent an L-1 corpectomy followed by placement of an expandable cage. The spines then underwent placement of lateral instrumentation consisting of 4 monoaxial screws and 2 rods with 2 cross-connectors, short-segment pedicle screw fixation involving 1 level above and below the corpectomy, and long-segment pedicle screw fixation (2 levels above and below). The order of instrumentation was randomized in the 8 specimens. Testing was conducted for each fixation technique. The spines were tested with a pure moment of 6 Nm in all 6 degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In flexion, extension, and left/right lateral bending, posterior long-segment instrumentation had significantly less motion compared with the intact state. Additionally, posterior long-segment instrumentation was significantly more rigid than short-segment and lateral instrumentation in flexion, extension, and left/right lateral bending. In axial rotation, the posterior long-segment construct as well as lateral instrumentation were not significantly more rigid than the intact state. The posterior long-segment construct was the most rigid in all 6 degrees of freedom. In the setting of highly unstable fractures requiring anterior reconstruction, and involving all 3 columns, long-segment posterior pedicle screw constructs are the most rigid.
Mandelaris, George A; Spagnoli, Daniel B; Rosenfeld, Alan L; McKee, James; Lu, Mei
2015-01-01
This case report describes a tissue-engineered reconstruction with recombinant human bone morphogenetic protein 2/acellular collagen sponge (rhBMP-2/ ACS) + cancellous allograft and space maintenance via Medpor Contain mesh in the treatment of a patient requiring maxillary and mandibular horizontal ridge augmentation to enable implant placement. The patient underwent a previously unsuccessful corticocancellous bone graft at these sites. Multiple and contiguous sites in the maxilla and in the mandibular anterior, demonstrating advanced lateral ridge deficiencies, were managed using a tissue engineering approach as an alternative to autogenous bone harvesting. Four maxillary and three mandibular implants were placed 9 and 10 months, respectively, after tissue engineering reconstruction, and all were functioning successfully after 24 months of follow-up. Histomorphometric analysis of a bone core obtained at the time of the maxillary implant placement demonstrated a mean of 76.1% new vital bone formation, 22.2% marrow/cells, and 1.7% residual graft tissue. Tissue engineering for lateral ridge augmentation with combination therapy requires further research to determine predictability and limitations.
DOT National Transportation Integrated Search
1978-09-01
This report describes the results of a before-and-after study to evaluate the effectiveness of dynamic sign systems in alerting motorists to the presence of narrow bridges on two lane rural highways. Vehicle speed and lateral placement (perpendicular...
ERIC Educational Resources Information Center
Flynn, Kylie Shawn
2012-01-01
This study examined students' movement in and out of special education and predictors for later special education placement. The sample ( N = 556) came from a response to intervention (RTI) study, specifically, a cluster-randomized control field trial that undertook the development and study of a hybrid Tier 1 (classroom instruction) and Tier 2…
Bodon, Gergely; Grimm, Andras; Hirt, Bernhard; Seifarth, Harald; Barsa, Pavel
2016-10-01
To present a method of posterior arch and lateral mass screw (PALMS) insertion and to prove its feasibility. Four formalin-fixed specimens and 40 macerated atlas vertebras were used to describe the relevant anatomy. The height of the posterior arch was measured on 42 consecutive patients using standard CT of the cervical spine. The operative technique and the special CT reconstructions used for preoperative planning are described. Eight patients underwent posterior fixation using this technique. We described the relevant anatomy and important anatomical landmarks of the posterior arch of the atlas. PALMS placement was modified according to these anatomical findings. Fifteen PALMSs were placed in eight patients using this technique without vascular or neural injury. It is feasible to place PALMS using the described technique. CT angiography is of crucial importance for preoperative planning using the described special reconstructions. The arch posterior to the lateral mass (APLM) is defined as the bone stock situated posterior to the lateral mass, respecting its convergence. The ideal entry point for a PALMS is on the APLM above the center of the converging lateral mass. A complete or incomplete ponticulus posticus and a retrotransverse foramen or groove can be used as an accessory landmark to refine the entry point.
Seismic Performance of Self-Consolidating Concrete Bridge Columns
DOT National Transportation Integrated Search
2017-09-01
The high amount of confining lateral steel required by seismic design provisions for rectangular bridge columns can cause steel congestion. The high amount of confining steel may hinder the placement of conventional concrete (CC). Self-consolidating ...
The Palatal Window for Treating an Incompletely Augmented Maxillary Sinus.
Florio, Salvatore; Suzuki, Takanori; Cho, Sang-Choon
2017-04-01
Maxillary sinus augmentation through a lateral window is reported as one of the most predictable bone augmentation procedures before implant placement. The elevation of the membrane represents a delicate and crucial step that allows the creation of the space for the bone graft material. If the elevation is not completed, the regenerated bone might be inadequate for the implant placement. In this case, a new intervention will be necessary to complete the bone augmentation. Reaccessing from a lateral window, however, would be challenging due to thickness of the buccal boney wall because of the first grafting procedure; therefore, a different approach has to be used. The aim of this case report is to present the palatal window technique for treating incompletely augmented maxillary sinus. The detailed step-by-step diagnostic and surgical procedures are described, and the advantages and limitations of the technique are discussed through a review of the literature.
Total phallic reconstruction using radial forearm free flap after iatrogenic penile amputation.
Angulo, J C; Arance, I; Gómez-Llorens, C; Esquinas, C; Gómez-Martín, C; Fernández-Cañamaque, J L
2017-09-01
The iatrogenic loss of the penis is a rare situation. We present a challenging case of deferred total penile reconstruction in a genetic male. A 57-year-old man with the loss of the penis due to a penile abscess and necrosis secondary to penile curvature surgery. The reconstruction was performed over several operations using a radial forearm free flap (RFFF) and placement of a customised inflatable prosthesis a year later. During the first operation, the penile abscess was drained, the necrotic residues were debrided and placement of hypogastric drainage. Seven weeks later, phalloplasty was performed with RFFF and a tube-in-tube neourethra was constructed. Multiple microsurgical anastomosis was performed, and the donor site was coated with a skin graft from the thigh of partial thickness. The surgery lasted 10hours and had the complication of hair growth in the neourethra, which required mechanical endoscopic depilation on repeated occasions. The patient regained penile sensitivity. Eighteen months after the phalloplasty, a Zephyr single-body inflatable prosthesis (Geneva, Switzerland) was implanted, using the tunica albuginea of the proximal corpus cavernosum. The patient was satisfied with the aesthetics and urinary and sensory function. Four months later, the patient is gaining confidence to consider penetration. Despite the risk of postoperative complications and the need for multiple operations, phallic reconstruction with RFFF and the placement of a customised prosthetic implant can improve urinary and sexual function secondary to the loss of the penis. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis
Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio
2013-01-01
♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical procedures seems to be equivalent to laparotomic placement with regard to complications and long-term catheter outcome. The number of patients able to receive peritoneal dialysis is substantially increased. PMID:23209040
Er, K; Bayram, M; Taşdemir, T
2011-12-01
To present the successful endodontic management of a maxillary lateral incisor tooth with a periradicular lesion caused by unintentional root damage after orthodontic miniscrew placement. A 22-year-old female was diagnosed with a skeletal Class II, Division 2 malocclusion with Class II molar and canine relationships on both sides. The treatment plan included distalization of the maxillary first molars bilaterally followed by full fixed appliance therapy. For the maxillary molar distalization, an appliance in conjunction with a miniscrew anchorage system was designed. Two months later, the patient came to the clinic with complaints of pain in the maxillary right lateral incisor region. On intraoral examination, intraoral sinus tracts were detected in the maxillary right buccal sulcus and palate. A large radiolucent lesion with a well-defined margin around the root of the maxillary right lateral incisor was seen. Root canal treatment was performed on the maxillary right lateral incisor tooth. The root canal was filled with gutta-percha and AH Plus sealer, using a lateral compaction technique. The final restoration of the tooth was completed using composite, and the tooth was reviewed after 10 months. The tooth was asymptomatic and radiographically showed repair of the lesion. Healing was achieved without any need for further endodontic or surgical intervention. Key learning points • This case illustrates the need to take care with miniscrews when performing orthodontic treatment, especially when the miniscrews are in close proximity to root apices. • The periradicular lesion as a result of miniscrew damage was successfully treated with root canal treatment. © 2011 International Endodontic Journal.
Bastian, Mauresa; Eggett, Dennis L; Jefferies, Laura K
2015-02-01
Question placement and usage of pre-evaluation instructions (PEI) in questionnaires for food sensory analysis may bias consumers' scores via carry-over effects. Data from consumer sensory panels previously conducted at a central location, spanning 11 years and covering a broad range of food product categories, were compiled. Overall acceptance (OA) question placement was studied with categories designated as first (the first evaluation question following demographic questions), after nongustation questions (immediately following questions that do not require panelists to taste the product), and later (following all other hedonic and just-about-right [JAR] questions, but occasionally before ranking, open-ended comments, and/or intent to purchase questions). Each panel was categorized as having or not having PEI in the questionnaire; PEI are instructions that appear immediately before the first evaluation question and show panelists all attributes they will evaluate before receiving test samples. Postpanel surveys were administered regarding the self-reported effect of PEI on panelists' evaluation experience. OA scores were analyzed and compared (1) between OA question placement categories and (2) between panels with and without PEI. For most product categories, OA scores tended to be lower when asked later in the questionnaire, suggesting evidence of a carry-over effect. Usage of PEI increased OA scores by 0.10 of a 9-point hedonic scale point, which is not practically significant. Postpanel survey data showed that presence of PEI typically improved the panelists' experience. Using PEI does not appear to introduce a meaningful carry-over effect. © 2015 Institute of Food Technologists®
Butler, Tracy R; O'Mara, Erin M; Wilson, Josephine F
2018-04-26
The Valence Hypothesis of cerebral lateralization of emotion suggests greater right hemisphere activation during negative mood and greater left hemisphere activation during positive mood. This can manifest as visual field attentional bias. Here, study participants completed an assessment of current mood state (PANAS) and made a drawing (Drawing 1). To induce positive or negative mood, participants played a game; then, the winner read a script depicting a positive interpersonal interaction and the loser read a script depicting a negative interpersonal interaction. Participants then drew a second picture (Drawing 2) and completed the PANAS. We hypothesized that the game outcome would change current mood state and hemispheric activation, which would be reflected in drawing placement. The placement of Drawing 2 moved right for winners and left for losers. Winners experienced a greater increase in positive affect from Time 1 to Time 2 than losers and had decreased negative affect from Time 1. Losers had decreased positive affect from Time 1 and had a greater increase in negative affect from Time 1 to Time 2 than winners. Our results suggest that change in current mood state may be objectively observed by evaluating hemispatial bias reflective of brain hemispheric activation with drawings. Copyright © 2018 Elsevier Inc. All rights reserved.
Panlilio, Carlomagno C; Jones Harden, Brenda; Harring, Jeffrey
2018-01-01
Guided by bio-ecological theory, this study aimed to: (1) identify heterogeneity in the developmental patterns of emotion regulation for maltreated preschool-aged children; (2) examine the role of gender, language, placement instability, cognitive stimulation, and emotional support on patterns of stability and change of emotion regulation over time; and (3) elucidate the role of emotion regulation/dysregulation patterns on later academic achievement. This study utilized data from the first cohort of the National Survey of Child and Adolescent Well-Being. Results using LCA and LTA models indicated stability and change in emotionally regulated vs. emotionally dysregulated latent classes across 4, 5, and 6 ½ years of age. Placement instability significantly increased the likelihood of being classified as emotionally dysregulated at wave 1. Moreover, children classified as emotionally dysregulated by age 6 ½ scored significantly lower than children who were classified as emotionally regulated on measures of reading and math achievement by age 10. Based on these findings, placement stability at first contact with CPS should be promoted in order to prevent cascading negative effects on emotion regulation. Additionally, children who are more emotionally dysregulated by the time they transition to formal schooling should receive increased socioemotional and socioemotional learning supports. Copyright © 2017 Elsevier Ltd. All rights reserved.
The effect of shear wall location in resisting earthquake
NASA Astrophysics Data System (ADS)
Tarigan, J.; Manggala, J.; Sitorus, T.
2018-02-01
Shear wall is one of lateral resisting structure which is used commonly. Shear wall gives high stiffness to the structure so as the structure will be stable. Applying shear wall can effectively reduce the displacement and story-drift of the structure. This will reduce the destruction comes from lateral loads such as an earthquake. Earlier studies showed that shear wall gives different performance based on its position in structures. In this paper, seismic analysis has been performed using response spectrum method for different Model of structures; they are the open frame, the shear wall at core symmetrically, the shear wall at periphery symmetrically, and the shear wall at periphery asymmetrically. The results are observed by comparing the displacement and story-drift. Based on the analysis, the placement of shear wall at the core of structure symmetrically gives the best performance to reduce the displacement and story-drift. It can reduce the displacement up to 61.16% (X-dir) and 70.60% (Y-dir). The placement of shear wall at periphery symmetrically will reduce the displacement up to 53.85% (X-dir) and 47.87% (Y-dir) while the placement of shear wall at periphery asymmetrically reducing the displacement up to 59.42% (X-dir) and 66.99% (Y-dir).
Yoshimoto, Marcelo; Watanabe, Il-sei; Martins, Marília T; Salles, Marcos B; Ten Eyck, Gary R; Coelho, Paulo G
2009-01-01
The present study assessed damage to the inferior alveolar nerve (IAN) following nerve lateralization and implant placement surgery through optical and transmission electron microscopy (TEM). IAN lateralization was performed in 16 adult female rabbits (Oryctolagus cuniculus). During the nerve lateralization procedure, one implant was placed through the mandibular canal, and the IAN was replaced in direct contact with the implant. The implant was placed in the right mandible, and the left side was used as a control (no surgical procedure). After 8 weeks, the animals were sacrificed and samples were prepared for optical and TEM analysis of IAN structural damage. Histomorphometric analysis was performed to determine the number and cross-sectional dimensions of nerve fascicles and myelin sheath thickness between experimental and control groups. The different parameters were compared by one-way analysis of variance at the 95% significance level. Alterations in the perineural and endoneural regions of the IAN, with higher degrees of vascularization, were observed in the experimental group. TEM showed that the majority of the myelinated nerve fibers were not affected in the experimental samples. No significant variation in the number of fascicles was observed, significantly larger fascicle height and width were observed in the control group, and significantly thicker myelin sheaths were observed in the experimental samples. IAN lateralization resulted in substantial degrees of tissue disorganization at the microstructural level because of the presence of edema. However, at the ultrastructural level, small amounts of fiber degeneration were observed.
Penile Prosthesis Implantation in Patients with a History of Total Phallic Construction.
Zuckerman, Jack M; Smentkowski, Katherine; Gilbert, David; Storme, Oscar; Jordan, Gerald; Virasoro, Ramon; Tonkin, Jeremy; McCammon, Kurt
2015-12-01
Outcomes following penile prosthesis implantation in patients with a history of total phallic construction are not well described. The aim of this study was to evaluate outcomes following neophallus penile prosthesis placement. Retrospective review penile prosthesis placement in patients with prior total phallic construction. GORE-TEX® (Gore Medical, Flagstaff, AZ) sleeve neotunica construction was utilized in all patients. Success defined as patient sexual activity with a functioning prosthesis. Thirty-one patients underwent neophallic prosthesis implantation at a mean 35.6 years of age. Prosthesis placement occurred at an average 56.3 months following phallic construction and follow-up was a mean of 59.7 months. Malleable prostheses were placed in 21 patients and inflatable in 10; implants were bilateral in 94%. Six percent experienced operative complications including a bladder injury (1) and phallic flap arterial injury (1). Postoperative complications occurred in 23% at a median 5.5 months following placement. Five prostheses were explanted secondary to infection or erosion and two additional required revisions. Of the explanted prosthesis two were later replaced without further complication. Eighty-one percent of patients were sexually active following prosthesis placement. Penile prosthesis placement is possible in patients with prior penile reconstruction/phallic construction. Although complications rates appear to be elevated in this population compared with historic controls of normal anatomic men, the majority of patients in this series were sexually active following prosthesis placement. This demonstrates the utility of prosthesis implantation in these difficult patients. © 2015 International Society for Sexual Medicine.
Evaluation of curve delineation signs on rural highways.
DOT National Transportation Integrated Search
1983-01-01
The three post-mounted delineator systems currently used in the state of Virginia were tested at five sites for their effectiveness in controlling run-off-the-road accidents. The changes in speed and lateral placement noted with the systems in place ...
NASA Automated Fiber Placement Capabilities: Similar Systems, Complementary Purposes
NASA Technical Reports Server (NTRS)
Wu, K. Chauncey; Jackson, Justin R.; Pelham, Larry I.; Stewart, Brian K.
2015-01-01
New automated fiber placement systems at the NASA Langley Research Center and NASA Marshall Space Flight Center provide state-of-art composites capabilities to these organizations. These systems support basic and applied research at Langley, complementing large-scale manufacturing and technology development at Marshall. These systems each consist of a multi-degree of freedom mobility platform including a commercial robot, a commercial tool changer mechanism, a bespoke automated fiber placement end effector, a linear track, and a rotational tool support structure. In addition, new end effectors with advanced capabilities may be either bought or developed with partners in industry and academia to extend the functionality of these systems. These systems will be used to build large and small composite parts in support of the ongoing NASA Composites for Exploration Upper Stage Project later this year.
Central vein stenosis: current concepts.
Agarwal, Anil K
2009-09-01
Central vein stenosis (CVS) is a common complication of the central venous catheter (CVC) placement. The prevalence of CVS has mostly been studied in those who present with symptoms such as swelling of the extremity, neck and breast. CVS compromises arteriovenous access and can be resistant to treatment. A previous history of CVC placement is the most important risk factor for the development of CVS later. Pacemaker and defibrillator wires are associated with a high incidence of CVS. Increasingly liberal use of peripherally inserted central catheters (PICC) is likely to increase the incidence of CVS. The trauma and inflammation related to the catheter placement is thought to result in microthrombi formation, intimal hyperplasia and fibrotic response, with development of CVS. Treatment of CVS by endovascular procedures involves angioplasty of the stenosis. An elastic or recurrent stenosis may require a stent placement. The long-term benefits of the endovascular procedures, although improved with newer technology, remain modest. Surgical options are usually limited. Future studies to explore the pathogenesis and the use of novel therapies to prevent and treat CVS are needed. The key to reducing the prevalence of CVS is in reducing CVC placement and placement of arteriovenous accesses prior to initiating dialysis. Early referral of the patients to the nephrologists by the primary care physicians is important. Timely vein mapping and referral to the surgeon for fistula creation can obviate the need for a CVC and decrease incidence of CVS.
Gribble, Nigel; Ladyshewsky, Richard K; Parsons, Richard
2017-01-01
This study investigated the changes in emotional intelligence (EI) of occupational therapy, physiotherapy, and speech pathology students (therapy students). Clinical placements have multiple benefits including the development of interprofessional skills, enhancing practice skills and interpersonal skills. Higher EI competencies have been shown to have a positive impact on patient outcomes, teamwork skills, dealing with stress, and patient satisfaction. Data for this study were collected at two time points: before third-year therapy students commenced extended clinical placements (T1 with 261 students) and approximately 7 months later after students had completed one or more clinical placements (T2 with 109 students). EI was measured using the Emotional Quotient Inventory 2.0 (EQ-i 2.0 ). Only one EI score, assertiveness, demonstrated a significant decline. No EI score showed a significant increase. A third or more of the students showed increases of five points or more in self-actualisation, emotional expression, independence, reality testing and optimism. However, of concern were the five EI scores where therapy students' EI scores decreased by more than five points: assertiveness (where 38% of students declined), problem solving (37%), impulse control (35%), self-actualisation (35%), and stress tolerance (33%). With EI scores declining for some students during clinical placements, there are implications for clinical supervisors and interprofessional facilitators as clinical performance may decline concurrently. There is a range of potential reasons that clinical placements could negatively influence the EI competencies of a therapy student, including poor clinical supervision, conflict between a student, and supervisor and failing a clinical placement. The research suggests that interprofessional facilitators and university educators might consider students undertaking EI tests before clinical placements.
Dierckman, Brian D; Goldstein, Jordan L; Hammond, Kyle E; Karas, Spero G
2012-01-01
The purpose of this study was to determine the maximum load and point of failure of the construct during tensioning of the lateral row of a transosseous-equivalent (TOE) rotator cuff repair. In 6 fresh-frozen human shoulders, a TOE rotator cuff repair was performed, with 1 suture from each medial anchor passed through the tendon and tied in a horizontal mattress pattern. One of 2 limbs from each of 2 medial anchors was pulled laterally over the tendon. After preparation of the lateral bone for anchor placement, the 2 limbs were passed through the polyether ether ketone (PEEK) eyelet of a knotless anchor and tied to a tensiometer. The lateral anchor was placed into the prepared bone tunnel but not fully seated. Tensioning of the lateral-row repair was simulated by pulling the tensiometer to tighten the suture limbs as they passed through the eyelet of the knotless anchor. The mode of failure and maximum tension were recorded. The procedure was then repeated for the second lateral-row anchor. The mean load to failure during lateral-row placement in the TOE model was 80.8 ± 21.0 N (median, 83 N; range, 27.2 to 115.8 N). There was no statistically significant difference between load to failure during lateral-row tensioning for the anterior and posterior anchors (P = .84). Each of the 12 constructs failed at the eyelet of the lateral anchor. Retrieval analysis showed no failure of the medial anchors, no medial suture cutout through the rotator cuff tendon, and no signs of gapping at the repair site. Our results suggest that the medial-row repair does not appear vulnerable during tensioning of the lateral row of a TOE rotator cuff repair with the implants tested. However, surgeons should exercise caution when tensioning the lateral row, especially when lateral-row anchors with PEEK eyelets are implemented. For this repair construct, the findings suggest that although the medial row is not vulnerable during lateral-row tensioning of a TOE rotator cuff repair, lateral-row anchors with PEEK eyelets appear vulnerable to early failure. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
New Padded Harness for Self-Acquisition of Resting 12-Lead ECGs
NASA Technical Reports Server (NTRS)
Schlegel, T. T.; Rood, A. T.
2011-01-01
We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.
Perry, Kristin J; Price, Joseph
2017-04-01
Predictors of the physical and relational aggressive behavior of children in foster care were examined ( N = 160, 50.9% male, M age = 7.57, SD = 2.39). First, predictors representative of children's placement histories were examined in relation to the children's aggression at T1. Next, predictors representing characteristics of the current family environment were examined in relation to the children's aggression at T2 (four months later). Results revealed that a greater number of prior group home placements and being in a non-kinship home were associated with higher physical aggression at T1. A greater number of prior group home placements, a fewer number of regular home placements, being in a non-kinship home, and prior removal from the home due to neglect were associated with higher relational aggression at T1. The results also revealed that higher foster sibling relational aggression at T1 predicted lower child physical aggression at T2. If foster siblings were biological children of the foster parent, higher levels of a foster sibling's physical aggression at T1 predicted reduced child physical aggression at T2. The opposite pattern was observed if foster siblings were not biological children of the foster parent. Lastly, longer time in the current placement, more children in the home, and the presence of a sibling that was a biological child of the parent predicted higher child relational aggression at T2. These findings provide initial insights into how placement history and current family environment are associated with the physical and relational aggressive behavior of children in foster care.
Muir, Kathryn B; Smoot, Charles P; Viera, Jennifer L; Sirkin, Maxwell R; Yoon, Brian; Bader, Julia; Smiley, Rebecca; Holt, Danielle; Hofmann, Luke J
2018-04-01
Controversy exists regarding the appropriate timing for placement of permanent intra-abdominal mesh after inadvertent enterotomy during elective hernia repair. The aim of this study was to examine mesh placement at variable postoperative periods and the subsequent risk of infection. Fifty rodents were divided into five groups. Groups one to four underwent laparotomy, enterotomy, and repair. Physiomesh® was placed at the index operation one, three, or seven days postoperatively in Groups 1, 2, 3, and 4. Group 5 underwent mesh placement only. Necropsy with mesh harvest was performed seven days after placement. Cultures of mesh were obtained and Fisher's exact test was used to compare groups. Bacterial growth postsonication was identified in 30, 30, 50, and 90 per cent versus 20 per cent in controls. Compared with controls, there was significantly increased risk of mesh infection when it was placed seven days after enterotomy (P = 0.006). There was no significant difference in bacterial growth when mesh was placed at the time of enterotomy, one or three days later. The risk of bacterial contamination of permanent mesh placed immediately after inadvertent enterotomy during elective hernia repair is as safe as placing mesh at one or three days. Placing mesh at seven days significantly increased the risk of mesh contamination.
Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.
Boboridis, Kostas G; Downes, Richard N
2005-06-01
The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.
Kinship foster care among African American youth: Interaction effects at multiple contextual levels
Rufa, Anne K.; Fowler, Patrick J.
2016-01-01
This study investigated the effects of kinship foster care on mental health outcomes among African American youth. Longitudinal data were used from a nationally representative sample of children and adolescents who were the subject of child protective services investigation from 1999 to 2000 (n=5,501). The secondary analyses focused on African American youth (n=225) placed into foster care. In structured interviews, current caregivers reported on youth internalizing and externalizing behaviors immediately following placement into out-of-home care and 18-months later. Path analysis tested a theoretical model that compared placements with kin to other formal out-of-home arrangements in context of setting characteristics, including aspects of caregiver and neighborhood disorder. Results suggested significant increases in internalizing symptoms over time for youth with more baseline mental health problems, as well as those placed in more distressed neighborhoods. Increased externalizing symptoms occurred among youth with greater baseline behavior problems, those placed in more problematic neighborhoods, and youth who experienced a placement change between assessments. Additionally, a combination of placement characteristics predicted increases in externalizing problems; youth placed in kinship foster care with older caregivers in poorer health exhibited greater increases in externalizing problems. Findings highlighted important contextual considerations for out-of-home placement among African American youth. PMID:26924865
Nam, D H; Shin, J H; Song, H Y; Jung, G S; Han, Y M
2006-02-01
To assess the safety and clinical effectiveness of the parallel placement of covered retrievable expandable metallic stents in the palliative treatment of malignant esophageal and tracheobronchial strictures. Under fluoroscopic guidance, parallel stents were placed in 12 symptomatic patients with both malignant esophageal and tracheobronchial strictures. Seven of these 12 patients also had an esophagorespiratory fistula (ERF) and one patient had an esophagocutaneous fistula. Technical success, clinical improvement, complications, and survival rates were evaluated. A total of 28 esophageal and airway stents were successfully placed. The grade of dysphagia and dyspnea score significantly decreased after stent placement (P=0.002 and 0.003, respectively). ERF and esophagocutaneous fistula were sealed off in all eight patients after esophageal stent placement; however, the esophagocutaneous fistula reopened 1 month later. Complications included stent migration or expectoration (n=3), tracheal compression by the esophageal stent (n=3), new fistula development due to covering membrane degradation of the esophageal stent (n=1), and symptomatic sputum retention (n=1). Stent removal was easily performed for two stents; one migrated stent and the other with covering membrane degradation. All 12 patients died within the mean survival period of 72.50 days (range 7-375 days). Parallel placement of covered retrievable expandable metallic stents is safe and effective for the palliative treatment of malignant esophageal and tracheobronchial strictures.
Bhattacharyya, Rahul; Ker, Andrew; Fogg, Quentin; Spencer, Simon J; Joseph, Jibu
2018-02-01
Incorrect femoral tunnel placement is the most common cause of graft failure during Anterior Cruciate Ligament (ACL) Reconstruction. A reliable landmark can minimize errors. To identify whether the Lateral Intercondylar Ridge (LIR) is a consistent anatomical structure and define its relationship with the femoral ACL insertion. Phase 1: we studied 23 femoral dry bone specimens macroscopically. Using a digital microscribe, the medial surface of the lateral femoral condyle was reconstructed (3D) to evaluate whether there was an identifiable bony ridge. Phase 2: 7 cadaveric specimens with intact soft tissues were dissected to identify the femoral ACL insertion. A 3D reconstruction of the femoral ACL insertion and the surface allowed us to define the relationship between the LIR and the ACL insertion. All specimens had a defined LIR on the medial surface of the lateral femoral condyle. The ridge was consistently located just anterior to the femoral ACL insertion. The ACL footprint was present in the depression between the ridge and the Inferior Articular Cartilage Margin (IACM). The mean distance from the midpoint of the IACM to the LIR was 10.1 mm. This is the first study to use the microscribe to digitally reconstruct the medial surface of the lateral femoral condyle. It shows that the LIR is a consistent anatomical structure that defines the anterior margin of the femoral ACL insertion, which guides femoral tunnel placement. Our findings support the ruler technique, which is a commonly used method for anatomic single bundle ACL reconstruction. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Mowat, D L; White, C
1985-04-01
Children who were scheduled for medical examination before entering school were followed in school one or two years later. Non-attenders had a two-fold risk of repeating grades, special class placement, referral for speech/language problems, teacher-reported learning or behavior problems, failure of vision or hearing screening, and transfer between schools. Absenteeism was also significantly more common. Children not brought in for preventive health care are at greater risk than others for difficulties in school.
Incarceration of umbilical hernia after radiological insertion of a Denver peritoneovenous shunt.
Ohta, Kengo; Shimohira, Masashi; Hashizume, Takuya; Kawai, Tatsuya; Kurosaka, Kenichiro; Suzuki, Kazushi; Watanabe, Kenichi; Shibamoto, Yuta
2013-03-01
We report a rare complication of incarceration of an umbilical hernia after Denver peritoneovenous shunt placement. A 50-year-old man presented with refractory ascites from liver cirrhosis. He also had an umbilical hernia. Because the ascites became uncontrollable, Denver peritoneovenous shunting was performed. The operation was successful and the ascites decreased. Ten days later, however, incarceration of the umbilical hernia occurred. A surgical repair was performed, but he died 2 days later. The cause of death was considered to be sepsis.
Housing First/HUD-VASH: Importance, Flaws, and Potential for Transformation: Response to Commentary.
Westermeyer, Joseph; Lee, Kathryn; Y Carr, Tegan Batres
2015-07-01
This paper consists of responses to issues raised in the accompanying Commentary. Our response is organized under three topics: (1) reasons regarding the importance of issues, (2) the need for a comprehensive framework in housing placement, and (3) conceptualization and scientific design (with details on contemporary methods for investigating unanticipated consequences when randomization is no longer feasible). Recurrences to substance use disorder in the American Society of Addiction Medicine (ASAM) housing placement condition are noted within hours or days, with rapid implementation of planned contingencies, and avoidance of enabling. Recurrences in the Housing First/HUD-VASH (HF/H-V) condition escape notice for weeks to months, and continued use is accepted as a core principle of the program. HF/H-V contingencies occur later for major disruptions, leading to discharge. For patients recruited from our clinic, HF/H-V performed poorly when compared to a long-accepted standard of care, the ASAM placement criteria.
Student attitudes to psychiatry and their clinical placements.
Budd, Simon; Kelley, Rachael; Day, Richard; Variend, Hannele; Dogra, Nisha
2011-01-01
Medical students consistently report low rates of interest in psychiatry as a career over time with negative perceptions of the specialty. Only 3-6% of students enter the specialty. To explore medical students' current career choices and attitudes to psychiatry and factors affecting these. Medical students at four UK medical schools completed a questionnaire related to career specialty choices and psychiatry and their psychiatry placement experiences. A total of 905 questionnaires were returned. Psychiatry was first career specialty choice in 4% but in the top three choices in 14%. The students in this group who had undertaken clinical placements were more positively inclined towards psychiatry, given more opportunities to practice and receive feedback on psychiatric skills, and more inclined to practice psychiatry later. One in seven students is interested in psychiatry. Psychiatrists need to find ways to identify these students and target them with individually tailored interventions to help recruitment into the specialty.
Iliac artery angioplasty : technique and results.
Brountzos, E N; Kelekis, D A
2004-10-01
Percutaneous angioplasty is widely used for the treatment of iliac artery occlusive disease. Access to the ipsi-lateral, or less commonly contralateral, common femoral artery is obtained under local anaesthesia; the lesion is crossed with a guidewire and dilated with an angioplasty balloon catheter. This technique yields excellent immediate results with very few complications. Stent placement is used in lesions not amenable to balloon angioplasty, in complications, and recurrences. Evidence suggests that balloon angioplasty is the procedure of choice for iliac artery occlusive lesions. Stent placement should be reserved for angioplasty failures. However, primary stent placement is indicated in total occlusions. Lesion morphology is an important determinant of immediate success and long-term patency. TASC lesions type A and B are best treated with angioplasty and stenting, while TASC lesions type C and D show better results with surgical treatment. The development of new stent designs may expand the indications of the percutaneous treatment.
Development and validation of a new guidance device for lateral approach stereotactic breast biopsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, K.; Kornecki, A.; Bax, J.
2009-06-15
Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authorsmore » present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.« less
Surgical stabilization of shoulder luxation in a pot-bellied pig.
Rubio-Martínez, Luis M; Rioja, Eva; Shakespeare, A S
2013-03-15
Case Description-A 4.6-month-old pot-bellied pig was evaluated because of non-weight-bearing lameness (grade 5/5) in the right forelimb of 4 days' duration. Clinical Findings-Clinical and radiographic examination revealed a closed, lateral luxation of the right shoulder joint. Treatment and Outcome-Initial attempts at closed reduction failed to provide adequate stability of the shoulder joint. Open reduction and internal fixation by placement of 2 lateral tension sutures with a system designed for canine cranial cruciate ligament repair provided adequate joint stability and a successful outcome. Conclusions and Clinical Relevance-Stabilization of the shoulder joint with lateral tension sutures after open reduction should be considered for management of lateral shoulder luxation in pot-bellied pigs.
The pigeon's distant visual acuity as a function of viewing angle.
Uhlrich, D J; Blough, P M; Blough, D S
1982-01-01
Distant visual acuity was determined for several viewing angles in two restrained White Carneaux pigeons. The behavioral technique was a classical conditioning procedure that paired presentation of sinusoidal gratings with shock. A conditioned heart rate acceleration during the grating presentation indicated resolution of the grating. The bird's acuity was fairly uniform across a large range of their lateral visual field; performance decreased slightly for posterior stimulus placement and sharply for frontal placements. The data suggest that foveal viewing is relatively less advantageous for acuity in pigeons than in humans. The data are also consistent with the current view that pigeons are myopic in frontal vision.
NASA Technical Reports Server (NTRS)
Giesy, Daniel P.; Christhilf, David M.
1999-01-01
A comparison is made between the results of trimming a High Speed Civil Transport (HSCT) concept along a reference mission profile using two trim modes. One mode uses the stabilator. The other mode uses fore and aft placement of the center of gravity. A comparison is make of the throttle settings (cruise segments) or the total acceleration (ascent and descent segments) and of the drag coefficient. The comparative stability of trimming using the two modes is also assessed by comparing the stability margins and the placement of the lateral and longitudinal eigenvalues.
NASA Astrophysics Data System (ADS)
Piercy, C.; Carrillo, C. C.; VanZomeren, C. M.; Berkowitz, J.; Chasten, M. A.; Golden, D.; Jahn, J.; Welp, T. L.; Yepsen, M.
2017-12-01
Over the winter of 2015-2016, the U.S. Army Corps of Engineers Philadelphia District partnered with New Jersey Department of Environmental Protection, The Nature Conservancy, Green Trust Alliance, Green Vest, and Princeton Hydro to implement a wetland thin layer placement on a salt marsh to the west of Avalon, New Jersey using dredged sediments removed from the Federal navigation channel in response to impacts from Hurricane Sandy. Prior to sediment placement, the marsh exhibited signs of degradation, including fragmentation of the marsh plain. The marsh is characterized by large, open water areas ( 1 m deep) fringed with overhanging banks and punctuated by small remnant ( 1-5 m) islands of intact marsh. The objective of the placement effort was to increase the elevation of degraded marsh areas to a level commensurate with the growth of low marsh vegetation dominated by Spartina alterniflora Loisel and to provide a small ( 5-15 cm) elevation boost to vegetated marsh areas surrounding the open water pools. We examine changes in inundation and tidal exchange resulting from the thin layer placement immediately after placement and a year later. Changes in sediment grain size and other factors are also considered. Coupling hydrologic measurements with observed vegetation recovery, we identify target elevations and sediment depths relative to mean sea level and mean high water consistent with rapid recovery in initially vegetated and open water areas.
Development of the Animal Management and Husbandry Online Placement Tool.
Bates, Lucy; Crowther, Emma; Bell, Catriona; Kinnison, Tierney; Baillie, Sarah
2013-01-01
The workplace provides veterinary students with opportunities to develop a range of skills, making workplace learning an important part of veterinary education in many countries. Good preparation for work placements is vital to maximize learning; to this end, our group has developed a series of three computer-aided learning (CAL) packages to support students. The third of this series is the Animal Management and Husbandry Online Placement Tool (AMH OPT). Students need a sound knowledge of animal husbandry and the ability to handle the common domestic species. However, teaching these skills at university is not always practical and requires considerable resources. In the UK, the Royal College of Veterinary Surgeons (RCVS) requires students to complete 12 weeks of pre-clinical animal management and husbandry work placements or extramural studies (EMS). The aims are for students to improve their animal handling skills and awareness of husbandry systems, develop communication skills, and understand their future clients' needs. The AMH OPT is divided into several sections: Preparation, What to Expect, Working with People, Professionalism, Tips, and Frequently Asked Questions. Three stakeholder groups (university EMS coordinators, placement providers, and students) were consulted initially to guide the content and design and later to evaluate previews. Feedback from stakeholders was used in an iterative design process, resulting in a program that aims to facilitate student preparation, optimize the learning opportunities, and improve the experience for both students and placement providers. The CAL is available online and is open-access worldwide to support students during veterinary school.
Tsuang, Fon-Yih; Chen, Chia-Hsien; Kuo, Yi-Jie; Tseng, Wei-Lung; Chen, Yuan-Shen; Lin, Chin-Jung; Liao, Chun-Jen; Lin, Feng-Huei; Chiang, Chang-Jung
2017-09-01
Minimally invasive spine surgery has become increasingly popular in clinical practice, and it offers patients the potential benefits of reduced blood loss, wound pain, and infection risk, and it also diminishes the loss of working time and length of hospital stay. However, surgeons require more intraoperative fluoroscopy and ionizing radiation exposure during minimally invasive spine surgery for localization, especially for guidance in instrumentation placement. In addition, computer navigation is not accessible in some facility-limited institutions. This study aimed to demonstrate a method for percutaneous screws placement using only the anterior-posterior (AP) trajectory of intraoperative fluoroscopy. A technical report (a retrospective and prospective case series) was carried out. Patients who received posterior fixation with percutaneous pedicle screws for thoracolumbar degenerative disease or trauma comprised the patient sample. We retrospectively reviewed the charts of consecutive 670 patients who received 4,072 pedicle screws between December 2010 and August 2015. Another case series study was conducted prospectively in three additional hospitals, and 88 consecutive patients with 413 pedicle screws were enrolled from February 2014 to July 2016. The fluoroscopy shot number and radiation dose were recorded. In the prospective study, 78 patients with 371 screws received computed tomography at 3 months postoperatively to evaluate the fusion condition and screw positions. In the retrospective series, the placement of a percutaneous screw required 5.1 shots (2-14, standard deviation [SD]=2.366) of AP fluoroscopy. One screw was revised because of a medialwall breach of the pedicle. In the prospective series, 5.8 shots (2-16, SD=2.669) were required forone percutaneous pedicle screw placement. There were two screws with a Grade 1 breach (8.6%), both at the lateral wall of the pedicle, out of 23 screws placed at the thoracic spine at T9-T12. Forthe lumbar and sacral areas, there were 15 Grade 1 breaches (4.3%), 1 Grade 2 breach (0.3%), and 1 Grade 3 breach (0.3%). No revision surgery was necessary. This method avoids lateral shots of fluoroscopy during screw placement and thus decreases the operation time and exposes surgeons to less radiation. At the same time, compared with the computer-navigated procedure, it is less facility-demanding, and provides satisfactory reliability and accuracy. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Accuracy of pedicle screw placement in patients with Marfan syndrome.
Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong
2017-03-21
There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P < 0.05), higher in lumbar region than in thoracic region (34.1% VS. 22.3%, P < 0.05) and higher in concave side than in convex side (33.5% VS. 21.9%, P < 0.05). No injury of visceral organs especially aorta erosion was noted in the series. 7 cases of dural tear caused by misplaced screws occurred, and 4 cases developed cerebro-spinal fluid leak. Drainage and pressure dressings were applied for these patients, and no infection was observed. Leg pain was observed in 7 cases, and 2 cases simultaneously complained of leg weakness. Revision surgery was conducted to remove the misplaced screws for these 2 patients. Conservative treatment was applied for the 5 patients without leg weakness. Symptoms of leg weakness and pain resolved in all patients. Placement of pedicle screw in Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.
NASA Astrophysics Data System (ADS)
Wang, Wu; Wang, Yong-Li; Chen, Mo; Chen, Liang; Zhang, Jian; Li, Yong-Dong; Li, Ming-Hua; Yuan, Guang-Yin
2016-11-01
Magnesium alloy covered stents have rarely been used in the common carotid artery (CCA). We evaluated the long-term efficacy of magnesium alloy covered stents in a lateral aneurysm model in rabbit CCA. Magnesium alloy covered stents (group A, n = 7) or Willis covered stents (group B, n = 5) were inserted in 12 New Zealand White rabbits and they were followed up for 12 months. The long-term feasibility for aneurysm occlusion was studied through angiograms; the changes in vessel area and lumen area were assessed with IVUS. Complete aneurysmal occlusion was achieved in all aneurysms. Angiography showed that the diameter of the stented CCA in group A at 6 and 12 months was significantly greater than the diameter immediately after stent placement. On intravascular ultrasound (IVUS) examination, the mean lumen area of the stented CCA in group A was significantly greater at 6 and 12 months than that immediately after stent placement; the mean lumen area was also significantly greater in group A than in group B at the same time points. The magnesium alloy covered stents proved to be an effective approach for occlusion of lateral aneurysm in the rabbit CCA; it provides distinct advantages that are comparable to that obtained with the Willis covered stent.
Ryan, Justin R; Chen, Tsinsue; Nakaji, Peter; Frakes, David H; Gonzalez, L Fernando
2015-11-01
Educational simulators provide a means for students and experts to learn and refine surgical skills. Educators can leverage the strengths of medical simulators to effectively teach complex and high-risk surgical procedures, such as placement of an external ventricular drain. Our objective was to develop a cost-effective, patient-derived medical simulacrum for cerebral lateral ventriculostomy. A cost-effective, patient-derived medical simulacrum was developed for placement of an external lateral ventriculostomy. Elastomeric and gel casting techniques were used to achieve realistic brain geometry and material properties. 3D printing technology was leveraged to develop accurate cranial properties and dimensions. An economical, gravity-driven pump was developed to provide normal and abnormal ventricular pressures. A small pilot study was performed to gauge simulation efficacy using a technology acceptance model. An accurate geometric representation of the brain was developed with independent lateral cerebral ventricular chambers. A gravity-driven pump pressurized the ventricular cavities to physiologic values. A qualitative study illustrated that the simulation has potential as an educational tool to train medical professionals in the ventriculostomy procedure. The ventricular simulacrum can improve learning in a medical education environment. Rapid prototyping and multi-material casting techniques can produce patient-derived models for cost-effective and realistic surgical training scenarios. Copyright © 2015 Elsevier Inc. All rights reserved.
Evaluation of wide edgelines on two-lane rural roads : interim report.
DOT National Transportation Integrated Search
1985-01-01
This interim report presents the results of an evaluation of 4-in and 8-in wide edgellnes on the lateral placement and speeds of vehicles on two-lane rural roads. Data were collected at twelve locations on sections of roadway covering 55.2 ml. Two me...
The Role of Placement History and Current Family Environment in Children’s Aggression in Foster Care
Perry, Kristin J.; Price, Joseph
2017-01-01
Predictors of the physical and relational aggressive behavior of children in foster care were examined (N = 160, 50.9% male, M age = 7.57, SD = 2.39). First, predictors representative of children’s placement histories were examined in relation to the children’s aggression at T1. Next, predictors representing characteristics of the current family environment were examined in relation to the children’s aggression at T2 (four months later). Results revealed that a greater number of prior group home placements and being in a non-kinship home were associated with higher physical aggression at T1. A greater number of prior group home placements, a fewer number of regular home placements, being in a non-kinship home, and prior removal from the home due to neglect were associated with higher relational aggression at T1. The results also revealed that higher foster sibling relational aggression at T1 predicted lower child physical aggression at T2. If foster siblings were biological children of the foster parent, higher levels of a foster sibling’s physical aggression at T1 predicted reduced child physical aggression at T2. The opposite pattern was observed if foster siblings were not biological children of the foster parent. Lastly, longer time in the current placement, more children in the home, and the presence of a sibling that was a biological child of the parent predicted higher child relational aggression at T2. These findings provide initial insights into how placement history and current family environment are associated with the physical and relational aggressive behavior of children in foster care. PMID:29551877
Zhang, Qiao; Zhang, Li Li; Yang, Yang; Lin, Yi Zhen; Miron, Richard J; Zhang, Yu Feng
To study the clinical effect of short implant placement using osteotome sinus floor elevation technique and tent-pole grafting technique with recombinant human bone morphogenetic protein 2 (rhBMP-2) in severely resorbed maxillary area. Eleven patients with insufficient bone height in the posterior maxillary area were included. According to the native bone height and crown height space (CHS), the patients were divided into two groups: immediate placement of short implants with simultaneous bone augmentation (group A, 5 patients) and delayed dental implant placement (4 to 6 months) after bone augmentation. The rhBMP-2 was added into a deproteinised bovine bone mineral (DBBM) bone grafting material to shorten the treatment procedure and enhance the final effect of bone augmentation in both groups. Tent-pole grafting technique was applied for vertical bone augmentation in group B (6 patients). The success rate of the implants placed was 100% in both groups. In group A, the short implants treatment was successful, with a vertical gain of 1.5 to 6.4 mm in bone height after 4 to 6 months. In group B, the tent-pole grafting procedure in combination with DBBM and rhBMP-2 increased vertical bone height between 3.1 and 8.1 mm, an optimistic and adequate increase for implant placement. This bone increase was maintained following implant placement and final crown placement in the maxillary region (3.5 to 7.3 mm). The tent-pole grafting technique was a viable alternative choice to lateral sinus floor elevation in cases with excessive CHS. The application of rhBMP-2 with a shortened treatment time demonstrated positive outcomes in sinus floor augmentation procedures.
Marković, Aleksa; Mišić, Tijana; Miličić, Biljana; Calvo-Guirado, Jose Luis; Aleksić, Zoran; Ðinić, Ana
2013-07-01
The study aimed to investigate the effect of surgical technique, implant macrodesign and insertion torque on bone temperature changes during implant placement. In the in vitro study, 144 self-tapping (blueSKY(®) 4 × 10 mm; Bredent) and 144 non-self-tapping (Standard implant(®) 4.1 × 10 mm; Straumann) were placed in osteotomies prepared in pig ribs by lateral bone condensing or bone drilling techniques. The maximum insertion torque values of 30, 35 and 40 Ncm were used. Real-time bone temperature measurement during implant placement was performed by three thermocouples positioned vertically, in tripod configuration around every osteotomy, at a distance of 5 mm from it and at depths of 1, 5 and 10 mm. Data were analysed using Kruskal-Wallis, Mann-Whitney U-tests and Regression analysis. Significant predictor of bone temperature at the osteotomy depth of 1 mm was insertion torque (P = 0.003) and at the depth of 10-mm implant macrodesign (P = 0.029), while no significant predictor at depth of 5 mm was identified (P > 0.05). Higher insertion torque values as well as non-self-tapping implant macrodesign were related to higher temperatures. Implant placement in sites prepared by bone drilling induced significantly higher temperature increase (P = 0.021) compared with bone condensing sites at the depth of 5 mm, while no significant difference was recorded at other depths. Compared with 30 Ncm, insertion torque values of 35 and 40 Ncm produced significantly higher temperature increase (P = 0.005; P = 0.003, respectively) at the depth of 1 mm. There was no significant difference in temperature change induced by 35 and 40 Ncm, neither by implant macrodesign at all investigated depths (P > 0.05). Placement of self-tapping implants with low insertion torque into sites prepared by lateral bone condensing technique might be advantageous in terms of thermal effect on bone. © 2012 John Wiley & Sons A/S.
Shea, Kevin G; Cannamela, Peter C; Fabricant, Peter D; Terhune, E Bailey; Polousky, John D; Milewski, Matthew D; Ganley, Theodore J; Anderson, Allen F
2017-03-15
This study was conducted to evaluate the spatial relationship of the anterior cruciate ligament (ACL) and lateral collateral ligament (LCL) femoral footprint origins in knee specimens from skeletally immature donors as viewed on lateral radiographs. Fourteen cadaver specimens of skeletally immature knees from children between 7 and 11 years old at the time of death were examined through gross dissection. Metallic pins were placed at the center of the ACL and LCL femoral footprints, and computed tomography (CT) scans were performed. Sagittal plane CT images were merged to create a view analogous to an intraoperative C-arm image with overlaid ACL and LCL ligament footprints. Ligament origins were then measured as a percent of the epiphyseal depth (% P-A [posterior-anterior]) and height (% P-D [proximal-distal]). The ACL origin was centered at a point located 14% (14% P-A) of the total lateral femoral condyle (LFC) depth from the most posterior aspect of the LFC and 38% (38% P-D) of the LFC height from the most proximal aspect of the posterior physis. The LCL origin was centered at a point 27% P-A and 37% P-D. When viewed on a sagittal CT reconstruction analogous to a perfect lateral intraoperative fluoroscopic view, the ACL footprint origin is posterior and slightly inferior to the LCL origin. Both origins are distal to the distal femoral physis and are posterior to the origin of the popliteus. This study demonstrates a consistent relationship between the origin of the ACL and LCL, which may be useful in guiding safe tunnel placement during all-epiphyseal ACL reconstruction in skeletally immature knees. This anatomic reference can be used intraoperatively to guide and radiographically evaluate ACL tunnel placement while avoiding the LCL origin in skeletally immature patients.
Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe
Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.
2014-01-01
Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628
Laparoscopy in patients following transverse rectus abdominis myocutaneous flap reconstruction.
Muller, C Y; Coleman, R L; Adams, W P
2000-07-01
We report our technique and experience performing laparoscopic pelvic surgery on four women after transverse abdominus rectus myocutaneous flap (TRAM). Examination under anesthesia is performed on all patients in the low lithotomy position parallel with the floor. The abdominal aorta is palpated and outlined. A pneumoperitoneum is created either by umbilical or left upper quadrant Veress placement. Patients with an acceptable umbilical location undergo port placement through the incision of the umbilical relocation. Other options include left upper quadrant or paramedian placement avoiding the ligamentum teres vessels. Lateral operative ports (5 mm) are placed with reference to the transverse incision present, the pelvic pathology, and the location of the umbilicus. Techniques of electrocautery, intra- and extracorporeal suturing and knot tying, and clips are preferred to minimize port size. Following unilateral or bilateral TRAM reconstruction, four consecutive breast cancer survivors underwent successful laparoscopic-assisted vaginal hysterectomy with oophorectomy using the periumbilical incision for trocar placement. The only complication was a superficial skin breakdown from an adhesive allergy that required 6 weeks for complete resolution. Laparoscopic pelvic surgery is feasible in women after TRAM reconstruction. Knowledge of anatomic and physiologic variations related to the TRAM procedure is necessary in planning a safe operation.
Geminiani, Alessandro; Papadimitriou, Dimitrios E V; Ercoli, Carlo
2011-11-01
Several techniques have been proposed to manage patients with insufficient bone height for implant placement in the posterior maxilla. The lateral approach to sinus elevation is a successful procedure, with percentages of success close to 100%. Unfortunately, a frequent complication encountered during sinus elevation procedure is perforation of the Schneiderian membrane. In this clinical report, the authors present the application of a diamond coated sonic tip and an air-driven sonic instrument, commonly used in prosthodontics for the preparation of the lateral window osteotomy during sinus augmentation procedures. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riegel, A; Klein, E; Tariq, M
Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before dailymore » image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.« less
Wiesen, Ari J; Sideridis, Kostas; Fernandes, Angelo; Hines, Jonathan; Indaram, Anant; Weinstein, Lenny; Davidoff, Samuel; Bank, Simmy
2006-12-01
PEG is a widely used method for providing nutritional support. Although pneumoperitoneum is a known finding after PEG placement, its true incidence is subject to debate. Small retrospective studies have found varied rates of free air after PEG placement. There were a total of 65 patients. To assess the true incidence of pneumoperitoneum and its clinical significance. Prospective study. Long Island Jewish Medical Center. We obtained upright and anterior-posterior chest radiographs of 65 patients within 3 hours after PEG placement. Type of PEG tube, gauge of the needle used, number of sticks, and indications were recorded. The presence of pneumoperitoneum on the initial chest film was considered to be a positive finding. After a positive result, a repeat chest film was obtained 72 hours later to determine whether there was progression or resolution of the free air. Patients enrolled in the study were also monitored clinically for evidence of peritonitis. Of the 65 patients who underwent PEG placement, 13 developed a pneumoperitoneum on the initial chest radiograph; there was complete resolution of pneumoperitoneum at 72 hours in 10 of the 13 patients. In 3 patients, the free air persisted but was of no clinical significance. The free air was quantified by measuring the height of the air column under the diaphragm and was graded with a scoring system (0, no air; 1, small; 2, moderate; 3, large). Eleven patients who underwent PEG died during the hospitalization; none of the deaths were related to the PEG placement or pneumoperitoneum. The other 54 patients were discharged to a skilled nursing facility. No patients in the study had clinical evidence of peritonitis. There were no adverse events, ie, infection or bleeding, associated with the PEG placement in any of the patients. Our data suggest that pneumoperitoneum after PEG placement is common and, in the absence of clinical symptoms, is of no clinical significance and does not warrant any further intervention.
Determination of anatomic landmarks for optimal placement in captive-bolt euthanasia of goats.
Plummer, Paul J; Shearer, Jan K; Kleinhenz, Katie E; Shearer, Leslie C
2018-03-01
OBJECTIVE To determine the optimal anatomic site and directional aim of a penetrating captive bolt (PCB) for euthanasia of goats. SAMPLE 8 skulls from horned and polled goat cadavers and 10 anesthetized horned and polled goats scheduled to be euthanized at the end of a teaching laboratory. PROCEDURES Sagittal sections of cadaver skulls from 8 horned and polled goats were used to determine the ideal anatomic site and aiming of a PCB to maximize damage to the midbrain region of the brainstem for euthanasia. Anatomic sites for ideal placement and directional aiming were confirmed by use of 10 anesthetized horned and polled goats. RESULTS Clinical observation and postmortem examination of the sagittal sections of skulls from the 10 anesthetized goats that were euthanized confirmed that perpendicular placement and firing of a PCB at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear, resulted in consistent disruption of the midbrain and thalamus in all goats. Immediate cessation of breathing, followed by a loss of heartbeat in all 10 of the anesthetized goats, confirmed that use of this site consistently resulted in effective euthanasia. CONCLUSIONS AND CLINICAL RELEVANCE Damage to the brainstem and key adjacent structures may be accomplished by firing a PCB perpendicular to the skull over the anatomic site identified at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear.
Accuracy of external ventricular drainage catheter placement.
Abdoh, Mohammad Ghazi; Bekaert, Olivier; Hodel, Jérôme; Diarra, Salia Mamadou; Le Guerinel, Caroline; Nseir, Rémi; Bastuji-Garin, Sylvie; Decq, Philippe
2012-01-01
External ventricular drainage (EVD) is a freehand neurosurgical procedure performed routinely using the anatomical landmarks. The aim of this study was to determine the accuracy of EVD catheter freehand placement. Pre-operative and post-operative computed tomography scans for 66 consecutive EVDs performed in 56 adult patients (26 men, 30 women) in 2008 were retrospectively reviewed. Etiologies of acute hydrocephalus were subarachnoid or intraventricular haemorrhage (43 cases) or miscellaneous (13 cases). Pre-operative lateral ventricular volume, position of the burr hole, length of the catheter and its sagittal and coronal angular variations from a theoretical trajectory were measured. The EVD was placed on the right (53 cases) or left (13 cases) side. The mean pre-operative lateral ventricular volume was 51 cc (10-118 cc). The average distance from the burr hole to the midline was 28 mm (10-49 mm) and to the supra-orbital ridge was 101 mm (75-125 mm). The mean intracranial catheter length was 60 mm (from 39-102 mm). Only 50% of the EVDs in the coronal plane and 40% in the sagittal plane were placed with an angular variation of ±5° to the target. The tip was placed outside of the ventricles in three cases; 13 catheters crossed the midline, and five intracranial minor haemorrhages were detected. Freehand placement of EVDs does not have sufficient accuracy and may lead to drainage dysfunctions. This data suggests that a guidance system for EVD's would be required.
The new mid-scala electrode array: a radiologic and histologic study in human temporal bones.
Hassepass, Frederike; Bulla, Stefan; Maier, Wolfgang; Laszig, Roland; Arndt, Susan; Beck, Rainer; Traser, Lousia; Aschendorff, Antje
2014-09-01
To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB's after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.
Prism adaptation and generalization during visually guided locomotor tasks.
Alexander, M Scott; Flodin, Brent W G; Marigold, Daniel S
2011-08-01
The ability of individuals to adapt locomotion to constraints associated with the complex environments normally encountered in everyday life is paramount for survival. Here, we tested the ability of 24 healthy young adults to adapt to a rightward prism shift (∼11.3°) while either walking and stepping to targets (i.e., precision stepping task) or stepping over an obstacle (i.e., obstacle avoidance task). We subsequently tested for generalization to the other locomotor task. In the precision stepping task, we determined the lateral end-point error of foot placement from the targets. In the obstacle avoidance task, we determined toe clearance and lateral foot placement distance from the obstacle before and after stepping over the obstacle. We found large, rightward deviations in foot placement on initial exposure to prisms in both tasks. The majority of measures demonstrated adaptation over repeated trials, and adaptation rates were dependent mainly on the task. On removal of the prisms, we observed negative aftereffects for measures of both tasks. Additionally, we found a unilateral symmetric generalization pattern in that the left, but not the right, lower limb indicated generalization across the 2 locomotor tasks. These results indicate that the nervous system is capable of rapidly adapting to a visuomotor mismatch during visually demanding locomotor tasks and that the prism-induced adaptation can, at least partially, generalize across these tasks. The results also support the notion that the nervous system utilizes an internal model for the control of visually guided locomotion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Takeda, Taro
We report the successful management of acute cholecystitis using cystic duct stent placement in 3 patients with inoperable malignant cystic duct obstruction (2 cholangiocarcinoma and 1 pancreatic carcinoma). All patients underwent stent placement in the bile duct, using an uncovered stent in 2 and a covered stent in 1, to relieve jaundice occurring 8-184 days (mean 120 days) before the development of acute cholecystitis. The occluded cystic duct was traversed by a microcatheter and a stent was implanted 4-17 days (mean 12 days) after cholecystostomy. Acute cholecystitis was improved after the procedure in all patients. Two patients died 3 andmore » 10 months later, while 1 has survived without cholecystitis for 22 months after the procedure to date.« less
Stærk, Mathilde; Bødtker, Henrik; Lauridsen, Kasper G; Løfgren, Bo
2017-01-01
Correct placement of the left automated external defibrillator (AED) electrode is rarely achieved. AED electrode placement is predominantly illustrated and trained with the rescuer sitting on the right side of the patient. Placement of the AED electrodes from the left side of the patient may result in a better overview of and access to the left lateral side of the thorax. This study aimed to investigate if training in automated external defibrillation on the left side compared to the right side of a manikin improves left AED electrode placement. Laypeople attending basic life support training were randomized to learn automated external defibrillation from the left or right side of a manikin. After course completion, participants used an AED and placed AED electrodes in a simulated cardiac arrest scenario. In total, 40 laypersons were randomized to AED training on the left (n=19 [missing data =1], 63% female, mean age: 47.3 years) and right (n=20, 75% female, mean age: 48.7 years) sides of a manikin. There was no difference in left AED electrode placement when trained on the left or right side: the mean (SD) distances to the recommended left AED electrode position were 5.9 (2.1) cm vs 6.9 (2.2) cm ( p =0.15) and to the recommended right AED electrode position were 2.6 (1.5) cm vs 1.8 (0.8) cm ( p =0.06), respectively. Training in automated external defibrillation on the left side of a manikin does not improve left AED electrode placement compared to training on the right side.
NASA Astrophysics Data System (ADS)
Hu, Rong-Pan; Xu, You-Lin; Zhan, Sheng
2018-01-01
Estimation of lateral displacement and acceleration responses is essential to assess safety and serviceability of high-rise buildings under dynamic loadings including earthquake excitations. However, the measurement information from the limited number of sensors installed in a building structure is often insufficient for the complete structural performance assessment. An integrated multi-type sensor placement and response reconstruction method has thus been proposed by the authors to tackle this problem. To validate the feasibility and effectiveness of the proposed method, an experimental investigation using a cantilever beam with multi-type sensors is performed and reported in this paper. The experimental setup is first introduced. The finite element modelling and model updating of the cantilever beam are then performed. The optimal sensor placement for the best response reconstruction is determined by the proposed method based on the updated FE model of the beam. After the sensors are installed on the physical cantilever beam, a number of experiments are carried out. The responses at key locations are reconstructed and compared with the measured ones. The reconstructed responses achieve a good match with the measured ones, manifesting the feasibility and effectiveness of the proposed method. Besides, the proposed method is also examined for the cases of different excitations and unknown excitation, and the results prove the proposed method to be robust and effective. The superiority of the optimized sensor placement scheme is finally demonstrated through comparison with two other different sensor placement schemes: the accelerometer-only scheme and non-optimal sensor placement scheme. The proposed method can be applied to high-rise buildings for seismic performance assessment.
Medial Patella Subluxation: Diagnosis and Treatment
McCarthy, Mark A.; Bollier, Mathew J.
2015-01-01
Medial patella subluxation is a disabling condition typically associated with previous patellofemoral instability surgery. Patients often describe achy pain with painful popping episodes. They often report that the patella shifts laterally, which occurs as the medial subluxed patella dramatically shifts into the trochlear groove during early knee flexion. Physical examination is diagnostic with a positive medial subluxation test. Nonoperative treatment, such as focused physical therapy and patellofemoral stabilizing brace, is often unsuccessful. Primary surgical options include lateral retinacular repair/imbrication or lateral reconstruction. Prevention is key to avoid medial patella subluxation. When considering patellofemoral surgery, important factors include appropriate lateral release indications, consideration of lateral retinacular lengthening vs release, correct MPFL graft placement and tension, and avoiding excessive medialization during tubercle transfer. This review article will analyze patient symptoms, diagnostic exam findings and appropriate treatment options, as well as pearls to avoid this painful clinical entity. PMID:26361441
High-Risk Infants of Teenage Mothers: Later Candidates for Special Education Placements?
ERIC Educational Resources Information Center
Landerholm, Elizabeth
1982-01-01
The article reviews research on teenage pregnancy, the special educational needs of the infants of these teenage mothers, and current intervention programs for teenage mothers and infants. Research demonstrates that intervention programs can impact infant mortality, morbidity, and prematurity as well as infant social and cognitive development.…
The Role of Mediators in the Development of Longitudinal Mathematics Achievement Associations
ERIC Educational Resources Information Center
Watts, Tyler W.; Duncan, Greg J.; Chen, Meichu; Claessens, Amy; Davis-Kean, Pamela E.; Duckworth, Kathryn; Engel, Mimi; Siegler, Robert; Susperreguy, Maria I.
2015-01-01
Despite research demonstrating a strong association between early and later mathematics achievement, few studies have investigated mediators of this association. Using longitudinal data (n = 1,362), this study tested the extent to which mathematics self-concepts, school placement, executive functioning, and proficiency in fractions and division…
How Are Your Graduates Doing? Do They Still Love You?
ERIC Educational Resources Information Center
Saunders, Gary; Stivason, Charles
2010-01-01
Section 33 of the AACSB requirements for Specialized Accreditation of Accounting Programs requires that that each accounting program applying for specialized accreditation demonstrate its success with regard to the placement of students within three months of graduation and the career success of graduates at an appropriate later time (e.g., 5 or…
Fallesen, Peter
2013-12-01
Individuals who spent time in foster care as children fare on average worse than non-placed peers in early adult life. Recent research on the effect of foster care placement on early adult life outcomes provides mixed evidence. Some studies suggest negative effects of foster care placement on early adult outcomes, others find null effects. This study shows that differences in the average duration of foster care stays explain parts of these discordant findings and then test how foster care duration shapes later life outcomes using administrative data on 7220 children. The children experienced different average durations of foster care because of differences in exposure to a reform. Later born cohorts spent on average 3 months longer in foster care than earlier born cohorts. Isolating exogenous variation in duration of foster care, the study finds positive effects of increased duration of foster care on income and labor market participation. Copyright © 2013 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.
James, Evan W; LaPrade, Christopher M; Ellman, Michael B; Wijdicks, Coen A; Engebretsen, Lars; LaPrade, Robert F
2014-11-01
Anatomic root placement is necessary to restore native meniscal function during meniscal root repair. Radiographic guidelines for anatomic root placement are essential to improve the accuracy and consistency of anatomic root repair and to optimize outcomes after surgery. To define quantitative radiographic guidelines for identification of the anterior and posterior root attachments of the medial and lateral menisci on anteroposterior (AP) and lateral radiographic views. Descriptive laboratory study. The anterior and posterior roots of the medial and lateral menisci were identified in 12 human cadaveric specimens (average age, 51.3 years; age range, 39-65 years) and labeled using 2-mm radiopaque spheres. True AP and lateral radiographs were obtained, and 2 raters independently measured blinded radiographs in relation to pertinent landmarks and radiographic reference lines. On AP radiographs, the anteromedial and posteromedial roots were, on average, 31.9 ± 5.0 mm and 36.3 ± 3.5 mm lateral to the edge of the medial tibial plateau, respectively. The anterolateral and posterolateral roots were, on average, 37.9 ± 5.2 mm and 39.3 ± 3.8 mm medial to the edge of the lateral tibial plateau, respectively. On lateral radiographs, the anteromedial and anterolateral roots were, on average, 4.8 ± 3.7 mm and 20.5 ± 4.3 mm posterior to the anterior margin of the tibial plateau, respectively. The posteromedial and posterolateral roots were, on average, 18.0 ± 2.8 mm and 19.8 ± 3.5 mm anterior to the posterior margin of the tibial plateau, respectively. The intrarater and interrater intraclass correlation coefficients (ICCs) were >0.958, demonstrating excellent reliability. The meniscal root attachment sites were quantitatively and reproducibly defined with respect to anatomic landmarks and superimposed radiographic reference lines. The high ICCs indicate that the measured radiographic relationships are a consistent means for evaluating meniscal root positions. This study demonstrated consistent and reproducible radiographic guidelines for the location of the meniscal roots. These measurements may be used to assess root positions on intraoperative fluoroscopy and postoperative radiographs. © 2014 The Author(s).
Guyomarc'h, Pierre; Dutailly, Bruno; Couture, Christine; Coqueugniot, Hélène
2012-09-01
Accuracy of forensic facial approximation and superimposition techniques relies on the knowledge of anatomical correlations between soft and hard tissues. Recent studies by Stephan and collaborators (6,8,10) reviewed traditional guidelines leading to a wrong placement of the eyeball in the orbit. As those statements are based on a small cadaver sample, we propose a validation of these findings on a large database (n = 375) of living people. Computed tomography scans of known age and sex subjects were used to collect landmarks on three-dimensional surfaces and DICOM with TIVMI. Results confirmed a more superior and lateral position of the eyeball relatively to the orbital rims. Orbital height and breadth were used to compute regression formulae and proportional placement using percentages to find the most probable position of the eyeball in the orbit. A size-related sexual dimorphism was present but did not impact on the prediction accuracy. © 2012 American Academy of Forensic Sciences.
Pozzi, A; Tallarico, M; Barlattani, A
2012-06-01
The aim of the study was to describe an unusual method to stabilize the surgical template during the treatment of a severely resorbed edentulous mandible by means of computer-guided implant surgery. Pre-operative computer-based planning revealed the difficulty to stabilize the surgical template in a 67-year-old healthy woman. A deviation of the original NobelGuide™ protocol was performed to ensure the stability of the surgical template: four anchor pins were used to stabilize the surgical template, two in the buccal side of the anterior template and two unusual pins were placed in the lingual site. Four straight TiUnite® Nobel Biocare™ implants were then placed, according to a modified All-on-4™ concept procedure, to avoid graft procedures and to reduce the cumulative chair-side treatment time and costs. A temporary restoration was placed immediately after implant placement. Three months later a definitive, full acrylic restoration was delivered.
Changing nest placement of Hawaiian Common Amakihi during the breeding cycle
van Riper, Charles; Kern, M. D.; Sogge, M. K.
1993-01-01
We studied the nesting behavior of the Common Amakihi (Hemignathus virens) from 1970-1981 on the island of Hawaii to determine if the species alters nest placement over a protracted 9-month breeding season. Birds preferentially chose the southwest quadrant of trees in which to build nests during all phases of the breeding season. It appeared that ambient temperature (Ta) was a contributing factor to differential nest placement between early and late phases of the annual breeding cycle. When Ta is low during the early (December-March) breeding period, Common Amakihi selected exposed nesting locations that benefitted them with maximum solar insolation. However, in the later phase of the breeding period (April-July) when Ta was much higher, renesting birds selected nest sites deeper in the canopy in significantly taller trees. This is one of the few documented examples in which a species changes location of nest during a breeding season, thus allowing exploitation of temporally differing microclimatic conditions.
The effects of laterality on obstacle crossing performance in unilateral trans-tibial amputees.
De Asha, Alan R; Buckley, John G
2015-05-01
Unilateral trans-tibial amputees have bilaterally reduced toe clearance, and an increased risk of foot contact, while crossing obstacles compared to the able-bodied. While the able-bodied tend to lead with a 'preferred' limb it is equivocal whether amputees prefer to lead with the intact or prosthetic limb. This study determined the effects of laterality, compared to side of amputation, on amputees' obstacle crossing performance. To help understand why laterality could affect performance we also assessed knee proprioception for both limbs. Foot placement and toe clearance parameters were recorded while nine amputees crossed obstacles of varying heights leading with both their intact and prosthetic limbs. Joint-position sense was also assessed. Participants self-reported which limb was their preferred (dominant) limb. There were no significant differences in foot placements or toe clearance variability across lead-limb conditions. There were no significant differences in toe clearance between intact and prosthetic lead-limbs (p=0.28) but toe clearance was significantly higher when amputees led with their preferred compared to non-preferred limb (p=0.025). There was no difference in joint-position sense between the intact and residual knees (p=0.34) but joint-position sense tended to be more accurate for the preferred, compared to non-preferred limb (p=0.08). Findings suggest that, despite the mechanical constraints imposed by use of a prosthesis, laterality may be as important in lower-limb amputees as it is in the able bodied. This suggests that amputees should be encouraged to cross obstacles leading with their preferred limb. Copyright © 2015. Published by Elsevier Ltd.
Deeb, George R; Laskin, Daniel M; Deeb, Janina Golob
2017-03-01
The purpose of this study was to confirm the efficiency of using a lateral ramus block graft taken at the time of impacted mandibular third molar removal for horizontal ridge augmentation and implant placement. Ten patients had grafts obtained from the lateral aspect of the mandible during impacted third molar removal and placed in areas of horizontal ridge deficiency. Measurements made on cone-beam computerized tomograms after 4 months showed gains of 2.7 to 3.5 mm and 16 implants were placed successfully. In patients with impacted third molars requiring dental implants, simultaneous harvest of a lateral block bone graft is an efficient way of obtaining bone for horizontal ridge augmentation. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Scott, Marcia Strong; Delgado, Christine F.; Tu, Shihfen; Fletcher, Kathryn L.
2005-01-01
In this study, predictive classification accuracy was used to select those tasks from a kindergarten screening battery that best identified children who, three years later, were classified as educable mentally handicapped or as having a specific learning disability. A subset of measures enabled correct classification of 91% of the children in…
ERIC Educational Resources Information Center
Buboltz, Walter, Jr.; Deemer, Eric; Hoffmann, Rebecca
2010-01-01
A content analysis of research published in the "Journal of Counseling Psychology" ("JCP") was conducted for Volumes 46 (1999) through 56 (2009). The analysis involved the placement of 514 articles in 15 substantive content categories. In addition, we identified the most frequently published authors, most frequent institutional affiliations, and…
Picelli, Alessandro; Tamburin, Stefano; Bonetti, Paola; Fontana, Carla; Barausse, Martina; Dambruoso, Francesca; Gajofatto, Francesca; Santilli, Valter; Smania, Nicola
2012-11-01
The aim of this study was to compare the clinical outcomes of manual needle placement, electrical stimulation, and ultrasonography-guided techniques for botulinum toxin injection into the gastrocnemius of adults with spastic equinus after stroke. After randomization into three groups, each patient received the same dose of botulinum toxin type A into the lateral and medial head of the gastrocnemius muscle (OnabotulinumtoxinA, 100U per head) of the affected leg. The manual needle placement group (n = 15) underwent injections using anatomic landmarks and palpation; the electrical stimulation group (n = 15) received injections with electrical stimulation guidance; and the ultrasonography group (n = 17) was injected under sonographic guidance. The modified Ashworth scale, the Tardieu scale, and the ankle passive range of motion were measured at baseline and 1 mo after injection. Nonparametric statistical analysis was used. One month after injection, the modified Ashworth scale improved better in the ultrasonography group than in the manual needle placement group (P = 0.008). The ankle passive range of motion improved better in the ultrasonography group than in the electrical stimulation (P = 0.004) and manual needle placement (P < 0.001) groups. No difference was found between groups for the Tardieu scale. Ultrasonography-guided injection technique could improve the clinical outcome of botulinum toxin injections into the gastrocnemius of adults with spastic equinus.
Stærk, Mathilde; Bødtker, Henrik; Lauridsen, Kasper G; Løfgren, Bo
2017-01-01
Background Correct placement of the left automated external defibrillator (AED) electrode is rarely achieved. AED electrode placement is predominantly illustrated and trained with the rescuer sitting on the right side of the patient. Placement of the AED electrodes from the left side of the patient may result in a better overview of and access to the left lateral side of the thorax. This study aimed to investigate if training in automated external defibrillation on the left side compared to the right side of a manikin improves left AED electrode placement. Methods Laypeople attending basic life support training were randomized to learn automated external defibrillation from the left or right side of a manikin. After course completion, participants used an AED and placed AED electrodes in a simulated cardiac arrest scenario. Results In total, 40 laypersons were randomized to AED training on the left (n=19 [missing data =1], 63% female, mean age: 47.3 years) and right (n=20, 75% female, mean age: 48.7 years) sides of a manikin. There was no difference in left AED electrode placement when trained on the left or right side: the mean (SD) distances to the recommended left AED electrode position were 5.9 (2.1) cm vs 6.9 (2.2) cm (p=0.15) and to the recommended right AED electrode position were 2.6 (1.5) cm vs 1.8 (0.8) cm (p=0.06), respectively. Conclusion Training in automated external defibrillation on the left side of a manikin does not improve left AED electrode placement compared to training on the right side. PMID:29066936
Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar
2018-06-14
The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.
Stab to second intercostal space: a bubbling extrapleural wound.
Jabbar, A; Reynolds, J V; Plunkett, P K
2005-12-01
A 37 year old man was found collapsed at the roadside and taken to the emergency department. Communication was difficult, as the patient could not speak English. There was a wound in the left second intercostal space on the midclavicular line, which was bleeding and was bubbling air. A drain was inserted, bleeding controlled, and his wounds sutured. Chest x ray later confirmed satisfactory placement of the drain. The following day, swelling and discharge indicated oesophageal damage, which was later confirmed by gastrografin swallow. With conservative management in hospital for 2 weeks, he made a full recovery and was discharged.
The Role of Mediators in the Development of Longitudinal Mathematics Achievement Associations
Watts, Tyler W.; Duncan, Greg J.; Chen, Meichu; Claessens, Amy; Davis-Kean, Pamela E.; Duckworth, Kathryn; Engel, Mimi; Siegler, Robert; Susperreguy, Maria Ines
2016-01-01
Despite research demonstrating a strong association between early and later mathematics achievement, few studies have investigated mediators of this association. Using longitudinal data (n=1362), we tested the extent to which mathematics self-concepts, school placement, executive functioning, and proficiency in fractions and division account for the association between mathematics achievement in first grade and at age 15. As hypothesized, a strong longitudinal association between first grade and adolescent mathematics achievement was present (β= .36) even after controlling for a host of background characteristics, including cognitive skills and reading ability. The mediators accounted for 39% of this association, with mathematics self-concept, gifted and talented placement, and knowledge of fractions and division, serving as significant mediators. PMID:26332124
Dott, Daltry; Canlas, Christopher; Sobey, Christopher; Obremskey, William; Thomson, Andrew Brian
Necrotizing fasciitis is an infection of the soft tissue that is characterized by rapidly spreading inflammation and subsequent necrosis. It is a rare complication of peripheral nerve blocks. We report a rare case of necrotizing fasciitis after placement of a peripheral nerve catheter. A 58-year-old woman presented for an elective right second metatarsal resection and received a sciatic nerve catheter for postoperative pain control. On postoperative day 7, clinical examination and imaging supported the diagnosis of necrotizing fasciitis. Multiple reports have been published of necrotizing fasciitis after single-shot peripheral nerve block injections, neuraxial anesthesia, and intramuscular injections. This case highlights the potential for the rare complication of necrotizing fasciitis after peripheral nerve catheter placement.
Li, Juanjuan; Lee, Kyungmo; Chen, Haohua; Ou, Guomin
2013-11-01
Because of the low bone quality in the posterior maxilla, edentulism in this area often results in a resorbed osseous structure and a pneumatized maxillary sinus, which makes dental implant surgery in the posterior maxilla a challenge. Two main surgical approaches are available for the sinus lift procedure: lateral and crestal. Improvement of the maxillary sinus floor elevation technique and increase in predictability are desirable. This article describes an innovative approach to maxillary sinus floor elevation with piezoelectric surgery and hydraulic pressure for xenograft and simultaneous implant placement in situations with insufficient residual alveolar bone. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Materne, Michelle; Henderson, Amanda; Eaton, Emma
2017-09-01
Quality clinical placement experiences have been associated with nurses' workplace social capital. Social capital is broadly understood as the social organisation of trust, norms and networks that benefit society. Building social capital in the workplace may benefit experiences of staff and students. The aim of this study was to assess the impact of building workplace social capital on student nurse perceptions of clinical learning experiences. A quality improvement process was measured through repeated student surveys. First, second, third year students (n = 1176) from three universities completed a validated Student Clinical Learning Culture Survey (SCLCS) following their placement, at the commencement of quality improvement initiatives and five years later. The SCLCS measured students' perceptions of social affiliation, their motivation, satisfaction and dissatisfaction with clinical contexts. The first year of systematic changes focused on increasing student numbers along with improving communication, trust and knowledge sharing, antecedents to workplace social capital. No change was evident after the first year. Six years after commencement of building workplace social capital differences across all subscales, except dissatisfaction, were significant (p < 0.001). Leadership that promotes open communication and connections across staff and students to achieve common goals can build workplace social capital that enhances student placement experiences. Copyright © 2017 Elsevier Ltd. All rights reserved.
Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka
2012-05-01
Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.
van Olden, G D J
2014-12-01
The aim of this investigation was to evaluate the introduction of the VA-LCP anterior clavicle plate in the treatment of clavicle fractures. From March 2011 to March 2013, 42 clavicle fractures were treated; 40 were middle-third and 2 lateral-third, and 13/42 (31 %) patients were treated due to painful nonunion. Patient age ranged from 16 to 81 years. Complications were screw placement through the AC-joint, one superficial wound infection and one neuropraxia of the nervus radialis with dropping hand. We had some difficulties prebending both lateral to low and lateral to high but without clinical consequences. In all cases, the fracture healed with full functionality. After 1 year, 4 patients underwent a removal of the hardware. The VA-LCP anterior plate showed good reliability and sufficient stability with both middle-third, lateral and nonunion fractures of the clavicle.
Biffi, Mauro; Exner, Derek V; Crossley, George H; Ramza, Brian; Coutu, Benoit; Tomassoni, Gery; Kranig, Wolfgang; Li, Shelby; Kristiansen, Nina; Voss, Frederik
2013-01-01
Unwanted phrenic nerve stimulation (PNS) has been reported in ∼1 in 4 patients undergoing left ventricular (LV) pacing. The occurrence of PNS over mid-term follow-up and the significance of PNS are less certain. Data from 1307 patients enrolled in pre-market studies of LV leads manufactured by Medtronic (models 4193 and 4195 unipolar, 4194, 4196, 4296, and 4396 bipolar) were pooled. Left ventricular lead location was recorded at implant using a common classification scheme. Phrenic nerve stimulation symptoms were either spontaneously reported or identified at scheduled follow-up visits. A PNS-related complication was defined as PNS resulting in invasive intervention or the termination of LV pacing. Average follow-up was 14.9 months (range 0.0-46.6). Phrenic nerve stimulation symptoms occurred in 169 patients (12.9%). Phrenic nerve stimulation-related complications occurred in 21 of 1307 patients (1.6%); 16 of 738 (2.2%) in the unipolar lead studies, and 5 of 569 (0.9%) in the bipolar lead studies (P = 0.08). Phrenic nerve stimulation was more frequent at middle-lateral/posterior, and apical LV sites (139/1010) vs. basal-posterior/lateral/anterior, and middle-anterior sites (20/297; P= 0.01). As compared with an anterior LV lead position, a lateral LV pacing site was associated with over a four-fold higher risk of PNS (P= 0.005) and an apical LV pacing site was associated with over six-fold higher risk of PNS (P= 0.001). Phrenic nerve stimulation occurred in 13% of patients undergoing LV lead placement and was more common at mid-lateral/posterior, and LV apical sites. Most cases (123/139; 88%) of PNS were mitigated via electrical reprogramming, without the need for invasive intervention.
Tsai, Andrew G; Ashworth, Timothy J; Marcus, Randall; Akkus, Ozan
2017-01-01
Iatrogenic subtrochanteric fractures of the femur can occur postoperatively following placement of screws in the lateral femoral cortex. Drilling holes below the lesser trochanter is generally avoided to prevent fatigue failure; however, there is little biomechanical evidence to support this recommendation. We hypothesized that hole placement below the level of the lesser trochanter will not accelerate fatigue failure compared to holes at the level of the lesser trochanter. Twelve matched-pairs of male fresh-frozen cadaveric femurs were used for biomechanical testing. A single screw hole was drilled through the lateral femoral cortex either at the level of the lesser trochanter (proximal-hole group) or below the lesser trochanter (distal-hole group). Each femur was cycled to failure using a physiologically-relevant loading model. Paired t-test was used to evaluate for a difference in cycles to failure between groups. There was no statistical difference in cycles to failure between the groups with the hole drilled at or below the lesser trochanter. The traditional recommendation to avoid drilling holes below the level of the lesser trochanter is based mainly on experience and case reports in the literature. The results of this study indicate that placing holes below the level of the lesser trochanter, in and of itself, may not pose any additional risk of fracture. Other important factors need to be considered, such as tapering of the lateral femoral cortex. There are often situations where the patient's anatomy and facture pattern is more conducive to placing a screw distal to the lesser trochanter. This study may allow surgeons greater flexibility in placing screws more distally in the lateral femoral cortex by demonstrating the safety of doing so, at least in the population studied.
Two Independent Contributions to Step Variability during Over-Ground Human Walking
Collins, Steven H.; Kuo, Arthur D.
2013-01-01
Human walking exhibits small variations in both step length and step width, some of which may be related to active balance control. Lateral balance is thought to require integrative sensorimotor control through adjustment of step width rather than length, contributing to greater variability in step width. Here we propose that step length variations are largely explained by the typical human preference for step length to increase with walking speed, which itself normally exhibits some slow and spontaneous fluctuation. In contrast, step width variations should have little relation to speed if they are produced more for lateral balance. As a test, we examined hundreds of overground walking steps by healthy young adults (N = 14, age < 40 yrs.). We found that slow fluctuations in self-selected walking speed (2.3% coefficient of variation) could explain most of the variance in step length (59%, P < 0.01). The residual variability not explained by speed was small (1.5% coefficient of variation), suggesting that step length is actually quite precise if not for the slow speed fluctuations. Step width varied over faster time scales and was independent of speed fluctuations, with variance 4.3 times greater than that for step length (P < 0.01) after accounting for the speed effect. That difference was further magnified by walking with eyes closed, which appears detrimental to control of lateral balance. Humans appear to modulate fore-aft foot placement in precise accordance with slow fluctuations in walking speed, whereas the variability of lateral foot placement appears more closely related to balance. Step variability is separable in both direction and time scale into balance- and speed-related components. The separation of factors not related to balance may reveal which aspects of walking are most critical for the nervous system to control. PMID:24015308
The Impact of Taking a College Pre-Calculus Course on Students' College Calculus Performance
ERIC Educational Resources Information Center
Sonnert, Gerhard; Sadler, Philip M.
2014-01-01
Poor performance on placement exams keeps many US students who pursue a STEM (science, technology, engineering, mathematics) career from enrolling directly in college calculus. Instead, they must take a pre-calculus course that aims to better prepare them for later calculus coursework. In the USA, enrollment in pre-calculus courses in two- and…
The anterolateral acromial approach for fractures of the proximal humerus.
Gardner, Michael J; Boraiah, Sreevathsa; Helfet, David L; Lorich, Dean G
2008-02-01
Displaced and unstable fractures of the proximal humerus are notoriously difficult to manage. Successful surgical treatment requires finding the appropriate balance between adequate exposure for reduction and rigid fixation and minimizing soft tissue dissection. The anterolateral acromial approach was developed to allow less invasive treatment of proximal humerus fractures. The plane of the avascular anterior deltoid raphe is utilized, and the axillary nerve is identified and protected. Anterior dissection near the critical blood supply is avoided, substantial muscle retraction is minimized, and the lateral plating zone is directly accessed. Over a 4-year period, 52 patients with acute displaced fractures of the proximal humerus were treated with the anterolateral acromial approach and either a locking plate or an intramedullary nail. Twenty-three patients were evaluated clinically at a minimum follow-up of 1 year (average, 28 months) by clinical examination for range of motion and nerve function and a QuickDASH score. There were no axillary nerve deficits postoperatively related to the approach, and the average QuickDASH score was 25.2 (0, best; 100, worst). This approach allowed direct access to the lateral fracture planes for fracture reduction and plate placement or safe nail and interlocking screw placement.
NASA Technical Reports Server (NTRS)
Ransom, J. S.; Moore, R.
1985-01-01
Half-tipped primary and lateral roots of Phaseolus vulgaris bend toward the side of the root on which the intact half tip remains. Therefore, tips of lateral and primary roots produce growth effectors capable of inducing gravicurvature. The asymmetrical placement of a tip of a lateral root onto a detipped primary root results in the root bending toward the side of the root onto which the tip was placed. That is, the lesser graviresponsiveness of lateral roots as compared with primary roots is not due to the inability of their caps to produce growth inhibitors. The more pronounced graviresponsiveness of primary roots is positively correlated with the presence of columella tissues that are 3.8 times longer, 1.7 times wider, and 10.5 times more voluminous than the columellas of lateral roots. We propose that the lack of graviresponsiveness exhibited by lateral roots is due to the fact that they (i) produce smaller amounts of the inhibitor than primary (i.e., strongly graviresponsive) roots and (ii) are unable to redistribute the inhibitor so as to be able to create a concentration gradient sufficient to induce a pronounced gravitropic response.
Cook, Jay B; Shaha, James S; Rowles, Douglas J; Bottoni, Craig R; Shaha, Steven H; Tokish, John M
2013-01-01
Modern techniques for the treatment of acromioclavicular (AC) joint dislocations have largely centered on free tendon graft reconstructions. Recent biomechanical studies have demonstrated that an anatomic reconstruction with 2 clavicular bone tunnels more closely matches the properties of native coracoclavicular (CC) ligaments than more traditional techniques. No study has analyzed tunnel position in regard to risk of early failure. To evaluate the effect of clavicular tunnel position in CC ligament reconstruction as a risk of early failure. Case series; Level of evidence, 4. A retrospective review was performed of a consecutive series of CC ligament reconstructions performed with 2 clavicular bone tunnels and a free tendon graft. The population was largely a young, active-duty military group of patients. Radiographs were analyzed for the maintenance of reduction and location of clavicular bone tunnels using a picture archiving and communication system. The distance from the lateral border of the clavicle to the center of each bone tunnel was divided by the total clavicular length to establish a ratio. Medical records were reviewed for operative details and functional outcome. Failure was defined as loss of intraoperative reduction. The overall failure rate was 28.6% (8/28) at an average of 7.4 weeks postoperatively. Comparison of bone tunnel position showed that medialized bone tunnels were a significant predictor for early loss of reduction for the conoid (a ratio of 0.292 vs 0.248; P = .012) and trapezoid bone tunnels (a ratio of 0.171 vs 0.128; P = .004); this correlated to an average of 7 to 9 mm more medial in the reconstructions that failed. Reconstructions performed with a conoid ratio of ≥0.30 were significantly more likely to fail (5/5, 100%) than were those performed lateral to a ratio of 0.30 (3/23, 13.0%) (P < .01). There were no failures when the conoid ratio was <0.25 (0/10, 0%). Conoid tunnel placement was also statistically significant for predicting return to duty in our active-duty population. Medial tunnel placement is a significant factor in risk for early failures when performing anatomic CC ligament reconstructions. Preoperative templating is recommended to evaluate optimal placement of the clavicular bone tunnels. Placement of the conoid tunnel at 25% of the clavicular length from the lateral border of the clavicle is associated with a lower rate of lost reduction and a higher rate of return to military duty.
Anatomic aspects of tibiotalocalcaneal nail arthrodesis.
Hyer, Christopher F; Cheney, Nick
2013-01-01
During the past 15 years, tibiotalocalcaneal nail arthrodesis has become an established procedure for the treatment of specific disorders of the hindfoot and ankle. However, controversy exists regarding the proper starting point for obtaining and maintaining the correct hindfoot position to allow successful fusion. One of the challenges with this procedure is aligning the tibial canal with the central talus and calcaneus for placement of the intramedullary nail. We performed a cadaver study to evaluate the radiographic and anatomic position of the tibial canal and the central talus as it relates to placement of a retrograde tibiotalocalcaneal nail. In our subjects, guide wires directed in an antegrade fashion down the tibial canal were more likely to enter lateral to the midline of the talus and miss the calcaneal body medially. These data have revealed a mismatch among the central axis of the tibia, talus, and calcaneus. Surgeons must pay careful attention to wire placement across these 3 bone segments during retrograde tibiotalocalcaneal nailing. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Cook, J L; Tomlinson, J L; Reed, A L
1999-01-01
To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having <1.5 mm of malreduction. Follow-up was available for 9 patients from 9 to 21 months after surgery. All of the fractures had healed. One minor (wire migration) and one major (implant failure) complication occurred. Mean lameness scores were 0 (n = 6), 0.5 (n = 2), and 1 (n = 1) at the time of final follow-up. No significant differences were found in follow-up ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.
Acromioclavicular joint reconstruction using the LockDown synthetic implant: a study with cadavers.
Taranu, R; Rushton, P R P; Serrano-Pedraza, I; Holder, L; Wallace, W A; Candal-Couto, J J
2015-12-01
Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer. ©2015 The British Editorial Society of Bone & Joint Surgery.
Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery.
Uribe, Juan S; Vale, Fernando L; Dakwar, Elias
2010-12-15
Literature review. The objective of this article is to examine current intraoperative electromyography (EMG) neurophysiologic monitoring methods and their application in minimally invasive techniques. We will also discuss the recent application of EMG and its anatomic implications to the minimally invasive lateral transpsoas approach to the spine. Minimally invasive techniques require that the same goals of surgery be achieved, with the hope of decreased morbidity to the patient. Unlike standard open procedures, direct visualization of the anatomy is decreased. To increase the safety of minimally invasive spine surgery, neurophysiological monitoring techniques have been developed. Review of the literature was performed using the National Center for Biotechnology Information databases using PUBMED/MEDLINE. All articles in the English language discussing the use of intraoperative EMG monitoring and minimally invasive spine surgery were reviewed. The role of EMG monitoring in special reference to the minimally invasive lateral transpsoas approach is also described. In total, 76 articles were identified that discussed the role of neuromonitoring in spine surgery. The majority of articles on EMG and spine surgery discuss the use of intraoperative neurophysiological monitoring (IOM) for safe and accurate pedicle screw placement. In general, there is a paucity of literature that pertains to intraoperative EMG neuromonitoring and minimally invasive spine surgery. Recently, EMG has been used during minimally invasive lateral transpsoas approach to the lumbar spine for interbody fusion. The addition of EMG to the lateral approach has contributed to decrease the complication rate from 30% to less than 1%. In minimally invasive approaches to the spine, the use of EMG IOM might provide additional safety, such as percutaneous pedicle screw placement, where visualization is limited compared with conventional open procedures. In addition to knowledge of the anatomy and image guidance, directional EMG IOM is crucial for safe passage through the psoas muscle during the minimally invasive lateral retroperitoneal approach.
Henning, P Troy; Wilson, Thomas J; Willsey, Matthew; John, Jessin K; Popadich, Miriana; Yang, Lynda J S
2017-03-01
Surgical transection of sensory nerves in the treatment of intractable neuropathic pain is a commonly performed procedure. At times these cases can be particularly challenging when encountering obese patients, when targeting deeper nerves or those with a variable branching pattern, or in the case of repeat operations. In this case series, the authors describe their experience with ultrasound-guided surgical instrument placement during transection of a saphenous nerve in the region of prior vascular surgery in 1 patient and in the lateral femoral cutaneous nerve in 2 obese patients. The authors also describe this novel technique and provide pilot data that suggests ultrasound-assisted surgery may allow for complex cases to be completed in an expedited fashion through smaller incisions.
Ball, P A; Benzel, E C; Baldwin, N G
1994-04-01
The use of bone plate instrumentation with screw fixation has proved to be a useful adjunctive measure in anterior cervical spine fusion surgery. Proper fitting, positioning, and attachment of this instrumentation have been shown to be frequently suboptimal if done without radiographic guidance. The most commonly used method of radiographic assistance for placement of this instrumentation is fluoroscopy. While this gives satisfactory technical results, it is expensive and time-consuming, and exposes the patient and the operating room personnel to ionizing radiation. The authors present a simple technique to ensure screw placement and plate fitting using Kirschner wires and a single lateral radiograph. This technique saves time, reduces exposure to radiation, and has led to satisfactory results in over 20 operative cases.
NASA Astrophysics Data System (ADS)
Reveil, Mardochee; Sorg, Victoria C.; Cheng, Emily R.; Ezzyat, Taha; Clancy, Paulette; Thompson, Michael O.
2017-09-01
This paper presents an extensive collection of calculated correction factors that account for the combined effects of a wide range of non-ideal conditions often encountered in realistic four-point probe and van der Pauw experiments. In this context, "non-ideal conditions" refer to conditions that deviate from the assumptions on sample and probe characteristics made in the development of these two techniques. We examine the combined effects of contact size and sample thickness on van der Pauw measurements. In the four-point probe configuration, we examine the combined effects of varying the sample's lateral dimensions, probe placement, and sample thickness. We derive an analytical expression to calculate correction factors that account, simultaneously, for finite sample size and asymmetric probe placement in four-point probe experiments. We provide experimental validation of the analytical solution via four-point probe measurements on a thin film rectangular sample with arbitrary probe placement. The finite sample size effect is very significant in four-point probe measurements (especially for a narrow sample) and asymmetric probe placement only worsens such effects. The contribution of conduction in multilayer samples is also studied and found to be substantial; hence, we provide a map of the necessary correction factors. This library of correction factors will enable the design of resistivity measurements with improved accuracy and reproducibility over a wide range of experimental conditions.
Reveil, Mardochee; Sorg, Victoria C; Cheng, Emily R; Ezzyat, Taha; Clancy, Paulette; Thompson, Michael O
2017-09-01
This paper presents an extensive collection of calculated correction factors that account for the combined effects of a wide range of non-ideal conditions often encountered in realistic four-point probe and van der Pauw experiments. In this context, "non-ideal conditions" refer to conditions that deviate from the assumptions on sample and probe characteristics made in the development of these two techniques. We examine the combined effects of contact size and sample thickness on van der Pauw measurements. In the four-point probe configuration, we examine the combined effects of varying the sample's lateral dimensions, probe placement, and sample thickness. We derive an analytical expression to calculate correction factors that account, simultaneously, for finite sample size and asymmetric probe placement in four-point probe experiments. We provide experimental validation of the analytical solution via four-point probe measurements on a thin film rectangular sample with arbitrary probe placement. The finite sample size effect is very significant in four-point probe measurements (especially for a narrow sample) and asymmetric probe placement only worsens such effects. The contribution of conduction in multilayer samples is also studied and found to be substantial; hence, we provide a map of the necessary correction factors. This library of correction factors will enable the design of resistivity measurements with improved accuracy and reproducibility over a wide range of experimental conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konya, Andras, E-mail: akonya@mdanderson.org; Stephens, L. Clifton; Wright, Kenneth C.
2011-10-15
Purpose: To evaluate the efficacy of ablation with selective arterial injection of pure ethiodized oil followed by arterial occlusion with 9:1 ethanol-Ethiodol mixture (EEM) and coil placement in normal rabbit kidneys and kidneys inoculated with VX-2 carcinoma. Materials and Methods: All experiments were conducted with Animal Care and Use Committee approval. In six rabbits (group 1), one kidney was embolized with pure Ethiodol until capillary stasis, followed by injection of 9:1 EEM until arterial stasis and then coil placement into the main renal artery. In 12 other rabbits, one kidney was inoculated with VX-2 tumor. Ethiodol and EEM embolization andmore » coil placement followed 7 days later (group 2, n = 6) or 11-14 days later (group 3, n = 6). Kidneys were evaluated (angiography, computed tomography, macro- and microscopy) 7 days after treatment. Results: Capillary stasis was achieved in groups 1, 2, and 3 with (mean {+-} standard deviation) 0.47 {+-} 0.03, 0.53 {+-} 0.02, and 0.56 {+-} 0.04 ml of pure Ethiodol, followed by 0.47 {+-} 0.05, 0.42 {+-} 0.03, and 0.38 {+-} 0.04 ml of EEM, respectively, which caused complete arterial occlusion in 17 of 18 kidneys. In group 1, all but one kidney showed at least 95% generalized coagulative necrosis. In group 2, all six kidneys exhibited 100% coagulative necrosis, with no viable tumor present. In group 3, 100% coagulative necrosis was present in all kidneys, with a small viable tumor in one. Conclusion: In the rabbit, selective arterial injection of pure Ethiodol can cause complete renal parenchyma and tumor ablation when it is followed by prompt, contiguous, and permanent occlusion of the arterial compartment.« less
Xu, Wei; Zhang, Xuming; Ke, Tie; Cai, Hongru; Gao, Xiang
2017-08-11
This study aimed to evaluate the application of 3D printing in assisting preoperative plan of pedicle screw placement for treating middle-upper thoracic trauma. A preoperative plan was implemented in seven patients suffering from middle-upper thoracic (T3-T7) trauma between March 2013 and February 2016. In the 3D printing models, entry points of 56 pedicle screws (Magerl method) and 4 important parameters of the pedicle screws were measured, including optimal diameter (ϕ, mm), length (L, mm), inclined angle (α), head-tilting angle (+β), and tail-tilting angle (-β). In the surgery, bare-hands fixation of pedicle screws was performed using 3D printing models and the measured parameters as guidance. A total of seven patients were enrolled, including five men and two women, with the age of 21-62 years (mean age of 37.7 years). The position of the pedicle screw was evaluated postoperatively using a computerized tomography scan. Totally, 56 pedicle screws were placed, including 33 pieces of level 0, 18 pieces of level 1, 4 pieces of level 2 (pierced lateral wall), and 1 piece of level 3 (pierced lateral wall, no adverse consequences), with a fine rate of 91.0%. 3D printing technique is an intuitive and effective assistive technology to pedicle screw fixation for treating middle-upper thoracic vertebrae, which improve the accuracy of bare-hands screw placement and reduce empirical errors. The trial was approved by the Ethics Committee of the Fujian Provincial Hospital. It was registered on March 1st, 2013, and the registration number was K2013-03-001.
Choi, Jisoo; Shin, Dong-Ah; Kim, Sohee
2017-03-15
A three-dimensional finite element model of intact lumbar spine was constructed and four surgical finite element models implanted with ball-and-socket artificial discs with four different radii of curvature were compared. To investigate biomechanical effects of the curvature of ball-and-socket artificial disc using finite element analysis. Total disc replacement (TDR) has been accepted as an alternative treatment because of its advantages over spinal fusion methods in degenerative disc disease. However, the influence of the curvature of artificial ball-and-socket discs has not been fully understood. Four surgical finite element models with different radii of curvature of ball-and-socket artificial discs were constructed. The range of motion (ROM) increased with decreasing radius of curvature in extension, flexion, and lateral bending, whereas it increased with increasing radius of curvature in axial torsion. The facet contact force was minimum with the largest radius of curvature in extension, flexion, and lateral bending, whereas it was maximum with the largest radius in axial torsion. It was also affected by the disc placement, more with posterior placement than anterior placement. The stress in L4 cancellous bone increased when the radius of curvature was too large or small. The geometry of ball-and-socket artificial disc significantly affects the ROM, facet contact force, and stress in the cancellous bone at the surgical level. The implication is that in performing TDR, the ball-and-socket design may not be ideal, as ROM and facet contact force are sensitive to the disc design, which may be exaggerated by the individual difference of anatomical geometry. N/A.
Santagata, Mario; Cecere, Atirge; Prisco, Rosario V E; Tartaro, Gianpaolo; D'Amato, Salvatore
2017-01-01
The purpose of this study was to report the outcome of the management of both horizontal and vertical defects of alveolar crest using the bone slat technique approach in conjunction with third molar removal prior to implant placement in the aesthetic area. We present a 20-year-old female patient who lost a maxillary lateral incisor. The objective of treatment was to replace the lateral incisor with an implant-supported crown restoration without interfering with the integrity and topography of the adjacent gingival tissues. Because the future implant site showed horizontal and vertical bone defect the Authors decided to perform bone regeneration. The need for such bone augmentation in the younger patient often coincides with the timing for third molar removal. By combining third molar extraction with bone harvest and alveolar grafting, the patient undergoes only one surgical approach. The bone height (9.5 mm) and width (5.7 mm) were measured at the point of interest (tooth 12) both before and after implant placement in the reconstructed panoramic and parasagittal views by Cone Beam Computed Tomography (CBCT) scan. The final results demonstrated an increase in length of 5 mm after bone slat technique (from 9.5 mm to 13.5 mm) and an increase in width of 1 mm (from 5.7 mm to 6.7 mm). ISQ measurements were recorded at the time of implant placement (the mean was: 68.5) and immediately after individualized screw-retained provisional crown (the mean was: 77). This technique is reliable and aesthetic and functional results appear to be stable and respect this requisite: simple and fast graft harvesting and low risk of morbidity especially in conjunction with third molar removal.
Santagata, Mario; Cecere, Atirge; Prisco, Rosario V.E.; Tartaro, Gianpaolo
2017-01-01
Summary Background The purpose of this study was to report the outcome of the management of both horizontal and vertical defects of alveolar crest using the bone slat technique approach in conjunction with third molar removal prior to implant placement in the aesthetic area. Methods We present a 20-year-old female patient who lost a maxillary lateral incisor. The objective of treatment was to replace the lateral incisor with an implant-supported crown restoration without interfering with the integrity and topography of the adjacent gingival tissues. Because the future implant site showed horizontal and vertical bone defect the Authors decided to perform bone regeneration. The need for such bone augmentation in the younger patient often coincides with the timing for third molar removal. By combining third molar extraction with bone harvest and alveolar grafting, the patient undergoes only one surgical approach. The bone height (9.5 mm) and width (5.7 mm) were measured at the point of interest (tooth 12) both before and after implant placement in the reconstructed panoramic and parasagittal views by Cone Beam Computed Tomography (CBCT) scan. Results The final results demonstrated an increase in length of 5 mm after bone slat technique (from 9.5 mm to 13.5 mm) and an increase in width of 1 mm (from 5.7 mm to 6.7 mm). ISQ measurements were recorded at the time of implant placement (the mean was: 68.5) and immediately after individualized screw-retained provisional crown (the mean was: 77). Conclusions This technique is reliable and aesthetic and functional results appear to be stable and respect this requisite: simple and fast graft harvesting and low risk of morbidity especially in conjunction with third molar removal. PMID:29682225
Nota, Jumpei; Takahashi, Hirotaka; Hakuba, Nobuhiro; Hato, Naohito; Gyo, Kiyofumi
2013-04-01
A new treatment of neural anosmia. To investigate the effects of basic fibroblast growth factor (bFGF)-gelatin hydrogel on recovery of neural anosmia in mice. Anosmia was induced by intraperitoneal injection of 3-methylindole, 200 mg/kg. One week later, the animals underwent 1 of the following 3 procedures bilaterally: (1) group A: single-shot intranasal drip infusion of phosphate-buffered saline, (2) group B: single-shot intranasal drip infusion of bFGF, and (3) group C: placement of bFGF-gelatin hydrogel in the nasal cavity. The olfactory function of the animal was evaluated by the odor-detection test (ODT) 2 and 4 weeks later. Following the testing, the animal was killed, the thickness of the olfactory epithelium was measured, and the number of olfactory marker protein (OMP)-positive cells was counted. Research installation. Mice. The placement of bFGF-gelatin hydrogel in the nasal cavity. An ODT, thickness of olfactory epithelium, the number of OMP-positive cells The ODT proved that neural anosmia recovered in group C but not in groups A and B. Histologically, olfactory epithelium became thicker and the number of OMP-positive cells increased in group C, while such functional and histologic recovery was poor in groups A and B. These findings suggested that placement of bFGF-gelatin hydrogel in the nasal cavity was an efficient way to facilitate recovery of neural anosmia. As a gelatin hydrogel degrades slowly in the body, bFGF is gradually released around the site of the lesion; thus, it constantly exerts its effects on neural regeneration.
Matheny, Keith E; Carter, Kenny B; Tseng, Ewen Y; Fong, Karen J
2014-10-01
The outcomes of endoscopic sinus surgery (ESS) for chronic rhinosinusitis (CRS) can be compromised by postoperative inflammation, recurrent polyposis, middle turbinate lateralization, and synechiae, often requiring subsequent interventions. A bioabsorbable steroid-eluting sinus implant placed in the operating room following ESS has been proven safe and effective in 2 randomized controlled trials and a subsequent meta-analysis, for its ability to preserve sinus patency, and reduce medical and surgical interventions. This trial sought to evaluate the safety, feasibility, and outcomes of implants placed in the office after achieving hemostasis. Twenty patients with CRS underwent ESS including bilateral ethmoidectomy. A steroid-eluting bioabsorbable implant was deployed into each ethmoid cavity in the office within 7 days after ESS. Endoscopic appearance of the ethmoid cavities was evaluated at 1 week, 2 weeks, and 4 weeks postoperatively by the operating surgeon and an independent blinded evaluator. Procedural tolerance was assessed at week 2 using a patient preference questionnaire. The 20-item Sino-Nasal Outcome Test (SNOT-20) questionnaire was completed at baseline, week 2, and week 4. In-office placement of steroid-eluting bioabsorbable implants was well tolerated, with 90% of patients very satisfied with the overall experience, and 80% very satisfied with the recovery process. At 1 month, there were no significant adhesions or frank polyposis, and middle turbinate lateralization was only 5%. Compared to baseline, ethmoid sinus inflammation was significantly reduced (p = 0.03), and the mean SNOT-20 score was significantly improved (p < 0.001). In-office placement of steroid-eluting bioabsorbable implants after achieving hemostasis was well tolerated and might improve local drug diffusion and surgical outcomes. © 2014 ARS-AAOA, LLC.
Growing Pains in the Advanced Placement Program: Do Tough Trade-offs Lie Ahead?
ERIC Educational Resources Information Center
Duffett, Ann; Farkas, Steve
2009-01-01
In 2002-2003, 1 million students participated in AP by taking at least one exam. Five years later, nearly 1.6 million did--a 50+ percent increase. But is growth all good? Might there be a downside? Are ill prepared students eroding the quality of the program? Perhaps harming the best and brightest? To find out, the Thomas B. Fordham Institute…
Collison, Claire; Prusik, Julia; Paniccioli, Steven; Briotte, Michael; Grey, Rachael; Feustel, Paul; Pilitsis, Julie G
2017-08-01
Intraoperative neuromonitoring (IONM) through electromyography (EMG) studies has been shown to be a safe, effective way to determine the laterality of the spinal cord and guide electrode placement during spinal cord stimulation (SCS). However, the use of IONM to predict post-operative energy requirements and midline has not been examined and offers a new avenue to streamline programming and device selection. Further, the impact of cerebrospinal fluid (CSF) thickness on intraoperative and post-operative amplitudes is understood but has not been explicitly characterized. A total of 24 patients undergoing SCS implantation for chronic pain had intraoperative EMG studies performed to determine physiologic midline. The intraoperative midline was compared to the midline determined on post-operative day 1 based on paresthesia patterns during programming. For patients who had thoracic leads placed, the amplitudes needed to induce abdominal and extremity lateralization during SCS placement were compared with the intensities needed to induce therapy at post-operative day 1. Additionally, we examined whether CSF thickness, body mass index, diabetes, drug use, and smoking correlated with intraoperative and post-operative amplitudes. Intraoperative EMG was able to predict post-operative paresthesia-based midline in 70.83% of patients. There was a statistically significant relationship between the intraoperative intensity needed to induce extremity lateralization with the post-operative intensity to induce therapy (p = 0.009) as well as the intraoperative intensity needed to stimulate abdominals with the post-operative intensity (p = 0.033). There was also a relationship seen between CSF thickness and the post-operative energy requirements in patients (p = 0.039). EMG accurately predicts post-operative energy requirements and midline in SCS patients. While 29.17% of patients did not have a match between their intraoperative and post-operative midlines, EMG testing was still valuable in guiding electrode placement and providing information to predict post-operative intensities. Additionally, CSF thickness correlated with amplitude settings on the first post-operative day. © 2017 International Neuromodulation Society.
Gallagher, Peter; Martin, Laura; Angel, Lori; Tomassoni, Gery
2007-02-01
The placement of left ventricular (LV) leads during cardiac resynchronization therapy (CRT) involves many technical difficulties. These difficulties increase procedural times and decrease procedural success rates. A total of 50 patients with severe cardiomyopathy (mean LV ejection fraction was 21 +/- 6%) and a wide QRS underwent CRT implantation. Magnetic navigation (Stereotaxis, Inc.) was used to position a magnet-tipped 0.014'' guidewire (Cronus guidewire) within the coronary sinus (CS) vasculature. LV leads were placed in a lateral CS branch, either using a standard CS delivery sheath or using a "bare-wire" approach without a CS delivery sheath. The mean total procedure time was 98.1 +/- 29.1 minutes with a mean fluoroscopy time of 22.7 +/- 15.1 minutes. The mean LV lead positioning time was 10.4 +/- 7.6 minutes. The use of a delivery sheath was associated with longer procedure times 98 +/- 32 minutes vs 80 +/- 18 minutes (P = 0.029), fluoroscopy times 23 +/- 15 minutes vs 13 +/- 4 minutes (P = 0.0007) and LV lead positioning times 10 +/- 6 minutes vs 4 +/- 2 minutes (P = 0.015) when compared to a "bare-wire" approach. When compared with 52 nonmagnetic-assisted control CRT cases, magnetic navigation reduced total LV lead positioning times (10.4 +/- 7.6 minutes vs 18.6 +/- 18.9 minutes; P = 0.005). If more than one CS branch vessel was tested, magnetic navigation was associated with significantly shorter times for LV lead placement (16.2 +/- 7.7 minutes vs 36.4 +/- 23.4 minutes; P = 0.004). Magnetic navigation is a safe, feasible, and efficient tool for lateral LV lead placement during CRT. Magnetic navigation during CRT allows for control of the tip direction of the Cronus 0.014'' guidewire using either a standard CS delivery sheath or "bare-wire" approach. Although there are some important limitations to the 0.014'' Cronus magnetic navigation can decrease LV lead placement times compared with nonmagnetic-assisted control CRT cases, particularly if multiple CS branches are to be tested.
SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voros, L; Cohen, G; Zaider, M
Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan imagemore » study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While limited to a handful of patients, our experience shows navigation and fluoroscopy guided placement yield similar results.« less
Ouanezar, Hervé; Blakeney, William G; Latrobe, Charles; Saithna, Adnan; Fernandes, Levi Reina; Delaloye, Jean Romain; Thaunat, Mathieu; Sonnery-Cottet, Bertrand
2018-03-03
Repairs of the posterior horn of the lateral meniscus can be technically challenging. In contrast to medial meniscus repairs, the capsule around the posterior segment attachment of the lateral meniscus is quite thin. This study evaluates the clinical results of an arthroscopic all-inside repair technique for unstable, vertical, lateral meniscus tears, using a suture repair placed directly into the popliteus tendon. A retrospective analysis of prospectively collected data from the SANTI database was performed. All patients who had undergone combined ACL reconstruction with lateral meniscus all-inside repair, using sutures placed in the popliteus tendon, between 2011 and 2015, were included. Patients were reviewed clinically at 1 and 2 years' follow-up. At final follow-up, all patients were contacted to identify if they underwent further surgery or had knee pain, locking or effusion. Symptomatic patients were recalled for clinical evaluation by a physician and Magnetic Resonance Imaging of the knee. Operative notes for those undergoing further surgery were reviewed and rates and type of re-operation, including for failed lateral meniscal repair were recorded. Two hundred patients (mean age 28.6 ± 10.2 years) with a mean follow-up of 45.5 ± 12.8 months (range 24.7-75.2) were included. The mean Subjective International Knee Documentation Committee (IKDC) at final follow-up was 85.0 ± 11.3. The post-operative mean side-to-side laxity measured at 1 year was 0.6 ± 1.0 mm. Twenty-six patients underwent re-operation (13%) at a mean follow-up of 14.8 ± 7.8 months. The ACL graft rupture rate was 5.0%. Other causes for re-operation included medial meniscus tear (2.5%), cyclops lesion (1.5%) and septic arthritis (0.5%). The lateral meniscus repair failure rate was 3.5%. No specific complications relating to placement of sutures in the popliteus tendon were identified. Arthroscopic all-inside repair of unstable, vertical, lateral meniscus tears using a suture placed in the popliteus tendon is a safe technique. It is associated with a very low failure rate with no specific complications. Level IV.
Shandling, Adrian; Donohue, Daniel; Tobias, Serge; Wu, Iris; Brar, Ramandeep
2010-01-01
Cardiac resynchronization therapy, which involves the placement of a pacing lead in the right atrium and in each ventricle, is effective in treating heart failure that is caused by left bundle branch block and cardiomyopathy. The left ventricular lead is usually placed into a lateral branch of the coronary sinus via the subclavian route. When the subclavian route is unavailable, insertion of a standard, passive-fixation coronary sinus lead via the femoral approach is feasible; however, the likelihood of subsequent dislodgment is high. Herein, we describe the placement of a novel, self-retaining, active-fixation coronary sinus lead—the Attain StarFix® Model 4195 OTW Lead—in an elderly heart-failure patient, via the femoral approach. We believe that this is the 1st report of this procedure. PMID:20200636
Liberale, Gabriel
2017-04-01
Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.
The Role of Mediators in the Development of Longitudinal Mathematics Achievement Associations.
Watts, Tyler W; Duncan, Greg J; Chen, Meichu; Claessens, Amy; Davis-Kean, Pamela E; Duckworth, Kathryn; Engel, Mimi; Siegler, Robert; Susperreguy, Maria I
2015-01-01
Despite research demonstrating a strong association between early and later mathematics achievement, few studies have investigated mediators of this association. Using longitudinal data (n = 1,362), this study tested the extent to which mathematics self-concepts, school placement, executive functioning, and proficiency in fractions and division account for the association between mathematics achievement in first grade and at age 15. As hypothesized, a strong longitudinal association between first-grade and adolescent mathematics achievement was present (β = .36) even after controlling for a host of background characteristics, including cognitive skills and reading ability. The mediators accounted for 39% of this association, with mathematics self-concept, gifted and talented placement, and knowledge of fractions and division serving as significant mediators. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.
Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K
2018-03-18
To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.
Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K
2018-01-01
AIM To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. METHODS An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System®). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. RESULTS Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. CONCLUSION Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results. PMID:29564210
Schizas, Constantin; Theumann, Nicolas; Kosmopoulos, Victor
2007-05-01
Several studies have looked at accuracy of thoracic pedicle screw placement using fluoroscopy, image guidance, and anatomical landmarks. To our knowledge the upper thoracic spine (T1-T6) has not been specifically studied in the context of screw insertion and placement accuracy without the use of either image guidance or fluoroscopy. Our objective was to study the accuracy of upper thoracic screw placement without the use of fluoroscopy or image guidance, and report on implant related complications. A single surgeon inserted 60 screws in 13 consecutive non-scoliotic spine patients. These were the first 60 screws placed in the high thoracic spine in our institution. The most common diagnosis in our patient population was trauma. All screws were inserted using a modified Roy-Camille technique. Post-operative axial computed tomography (CT) images were obtained for each patient and analyzed by an independent senior radiologist for placement accuracy. Implant related complications were prospectively noted. No pedicle screw misplacement was found in 61.5% of the patients. In the remaining 38.5% of patients some misplacements were noted. Fifty-three screws out of the total 60 implanted were placed correctly within all the pedicle margins. The overall pedicle screw placement accuracy was 88.3% using our modified Roy-Camille technique. Five medial and two lateral violations were noted in the seven misplaced screws. One of the seven misplaced screws was considered to be questionable in terms of pedicle perforation. No implant related complications were noted. We found that inserting pedicle screws in the upper thoracic spine based solely on anatomical landmarks was safe with an accuracy comparable to that of published studies using image-guided navigation at the thoracic level.
Inoue, Tomoo; Lin, Amity; Ma, Xiaokui; McKenna, Stephen L.; Creasey, Graham H.; Manley, Geoffrey T.; Ferguson, Adam R.; Bresnahan, Jacqueline C.; Beattie, Michael S.
2015-01-01
A significant proportion (estimates range from 16–74%) of patients with spinal cord injury (SCI) have concomitant traumatic brain injury (TBI), and the combination often produces difficulties in planning and implementing rehabilitation strategies and drug therapies. For example, many of the drugs used to treat SCI may interfere with cognitive rehabilitation, and conversely drugs that are used to control seizures in TBI patients may undermine locomotor recovery after SCI. The current paper presents an experimental animal model for combined SCI and TBI to help drive mechanistic studies of dual diagnosis. Rats received a unilateral SCI (75 kdyn) at C5 vertebral level, a unilateral TBI (2.0 mm depth, 4.0 m/s velocity impact on the forelimb sensori-motor cortex), or both SCI + TBI. TBI was placed either contralateral or ipsilateral to the SCI. Behavioral recovery was examined using paw placement in a cylinder, grooming, open field locomotion, and the IBB cereal eating test. Over 6 weeks, in the paw placement test, SCI + contralateral TBI produced a profound deficit that failed to recover, but SCI + ipsilateral TBI increased the relative use of the paw on the SCI side. In the grooming test, SCI + contralateral TBI produced worse recovery than either lesion alone even though contralateral TBI alone produced no observable deficit. In the IBB forelimb test, SCI + contralateral TBI revealed a severe deficit that recovered in 3 weeks. For open field locomotion, SCI alone or in combination with TBI resulted in an initial deficit that recovered in 2 weeks. Thus, TBI and SCI affected forelimb function differently depending upon the test, reflecting different neural substrates underlying, for example, exploratory paw placement and stereotyped grooming. Concurrent SCI and TBI had significantly different effects on outcomes and recovery, depending upon laterality of the two lesions. Recovery of function after cervical SCI was retarded by the addition of a moderate TBI in the contralateral hemisphere in all tests, but forepaw placements were relatively increased by an ipsilateral TBI relative to SCI alone, perhaps due to the dual competing injuries influencing the use of both forelimbs. These findings emphasize the complexity of recovery from combined CNS injuries, and the possible role of plasticity and laterality in rehabilitation, and provide a start towards a useful preclinical model for evaluating effective therapies for combine SCI and TBI. PMID:23770071
Inoue, Tomoo; Lin, Amity; Ma, Xiaokui; McKenna, Stephen L; Creasey, Graham H; Manley, Geoffrey T; Ferguson, Adam R; Bresnahan, Jacqueline C; Beattie, Michael S
2013-10-01
A significant proportion (estimates range from 16 to 74%) of patients with spinal cord injury (SCI) have concomitant traumatic brain injury (TBI), and the combination often produces difficulties in planning and implementing rehabilitation strategies and drug therapies. For example, many of the drugs used to treat SCI may interfere with cognitive rehabilitation, and conversely drugs that are used to control seizures in TBI patients may undermine locomotor recovery after SCI. The current paper presents an experimental animal model for combined SCI and TBI to help drive mechanistic studies of dual diagnosis. Rats received a unilateral SCI (75 kdyn) at C5 vertebral level, a unilateral TBI (2.0 mm depth, 4.0 m/s velocity impact on the forelimb sensori-motor cortex), or both SCI+TBI. TBI was placed either contralateral or ipsilateral to the SCI. Behavioral recovery was examined using paw placement in a cylinder, grooming, open field locomotion, and the IBB cereal eating test. Over 6weeks, in the paw placement test, SCI+contralateral TBI produced a profound deficit that failed to recover, but SCI+ipsilateral TBI increased the relative use of the paw on the SCI side. In the grooming test, SCI+contralateral TBI produced worse recovery than either lesion alone even though contralateral TBI alone produced no observable deficit. In the IBB forelimb test, SCI+contralateral TBI revealed a severe deficit that recovered in 3 weeks. For open field locomotion, SCI alone or in combination with TBI resulted in an initial deficit that recovered in 2 weeks. Thus, TBI and SCI affected forelimb function differently depending upon the test, reflecting different neural substrates underlying, for example, exploratory paw placement and stereotyped grooming. Concurrent SCI and TBI had significantly different effects on outcomes and recovery, depending upon laterality of the two lesions. Recovery of function after cervical SCI was retarded by the addition of a moderate TBI in the contralateral hemisphere in all tests, but forepaw placements were relatively increased by an ipsilateral TBI relative to SCI alone, perhaps due to the dual competing injuries influencing the use of both forelimbs. These findings emphasize the complexity of recovery from combined CNS injuries, and the possible role of plasticity and laterality in rehabilitation, and provide a start towards a useful preclinical model for evaluating effective therapies for combine SCI and TBI. Copyright © 2013 Elsevier Inc. All rights reserved.
Venous thrombosis and stenosis after peripherally inserted central catheter placement in children.
Shin, H Stella; Towbin, Alexander J; Zhang, Bin; Johnson, Neil D; Goldstein, Stuart L
2017-11-01
Peripherally inserted central catheters (PICCs) can lead to development of venous thrombosis and/or stenosis. The presence of venous thrombosis and/or stenosis may preclude children with chronic medical conditions from receiving lifesaving therapies, from hemodialysis in end-stage renal disease to total parenteral nutrition in short bowel syndrome. Several adult studies have found an association between PICCs and venous thrombosis and/or stenosis, but none has evaluated for this association in children. To determine the incidence of venous thrombosis and/or stenosis after PICC placement and identify factors that increase the risk of venous thrombosis and/or stenosis after PICC placement in children. We conducted a retrospective review of children ages 1-18 years with a PICC placed between January 2010 and July 2013 at our center, and included those who had at least one vascular imaging study of the ipsilateral extremity (Doppler ultrasound, venogram or MR angiogram) after PICC placement. Logistic regression was applied to determine risk factors for development of venous thrombosis and/or stenosis. One thousand, one hundred and ten upper extremity PICCs were placed, with 703 PICCs in the right and 407 PICCs in the left. Eight hundred fifty-one imaging studies (609 Doppler ultrasounds, 193 contrast venograms and 49 MR angiograms) were performed in 376 patients. The incidence of venous thrombosis and/or stenosis in the imaged cohort was 26.3%. PICC laterality, insertion site, duration, patient height to PICC diameter ratio, and number of PICCs per patient were not associated with development of venous thrombosis and/or stenosis. Additionally, primary diagnosis and symptoms at the time of imaging did not predict findings of venous thrombosis and/or stenosis. However, patients exposed to non-PICC central venous catheters (CVC) were more likely to develop venous thrombosis and/or stenosis (odds ratio 1.95, 1.10-3.45). More than a quarter of the vascular imaging studies performed in this study cohort showed previously unknown venous thrombosis and/or stenosis, irrespective of PICC laterality, insertion site, duration and size and the number of PICCs. A history of CVC was associated with a nearly two-fold increase in risk of venous thrombosis and/or stenosis after PICC placement. We suggest that PICCs and CVCs should be placed judiciously in all children, but especially in those with lifelong medical conditions who are more likely to incur direct consequences from limited vascular access.
Dodd, Tamsin E L; Deakin, Charles D; Petley, Graham W; Clewlow, Frank
2004-12-01
Firm paddle force during defibrillation lowers transthoracic impedance (TTI) and increases transmyocardial current, increasing the chances of successful cardioversion. Current protocols recommend that if defibrillation using the anterior-apical (AA) paddle position fails, the anterior-posterior (AP) position should be used. This generally requires the patient to be placed in the left lateral position with the operator leaning over the patient. Avoiding physical contact with the patient during defibrillation subjectively makes application of firm paddle force difficult in the AP position. We compared TTI between the AA and AP positions and between manual paddles and self-adhesive pads to establish if the AP position precludes firm paddle force and to compare TTI between paddles and self-adhesive pads. Twenty-one consecutive patients undergoing elective cardioversion (age 39-82) were studied. TTI was measured between pairs of manually held paddles and self-adhesive pads using AA placement with the patient supine, and AP placement with the patient left lateral position. Mean TTI using the AP electrode position was lower using manual paddles (66.5 Omega; 95% CI 60.2-72.9 Omega) than that using self-adhesive pads (92.1 Omega; 95% CI 81.5-102.7 Omega; 95% CI between the mean =15.8-35.5 Omega; P <0.0001). TTI was significantly less using the manual paddles compared with self-adhesive pads in both AA and AP positions (P <0.0001). Despite the subjective difficulties of defibrillating patients in the AP position whilst leaning over them, use of manual paddles achieves a lower TTI than that achieved with self-adhesive pads.
Brountzos, Elias N; Vasdekis, Spyros; Kostopanagiotou, Georgia; Danias, Nikolaos; Alexopoulou, Efthymia; Petropoulou, Konstantina; Gouliamos, Athanasios; Perros, Georgios
2007-01-01
We report a patient with life-threatening gastrointestinal bleeding caused by a secondary aorto-enteric fistula. Because the patient had several comorbid conditions, we succesfully stopped the bleeding by endovascular placement of a bifurcated aortic stent-graft. The patient developed periaortic infection 4 months later, but he was managed with antibiotics. The patient is well 1 year after the procedure.
Defibrillation efficacy of different electrode placements in a human thorax model.
de Jongh, A L; Entcheva, E G; Replogle, J A; Booker, R S; Kenknight, B H; Claydon, F J
1999-01-01
The objective of this study was to measure the defibrillation threshold (DFT) associated with different electrode placements using a three-dimensional anatomically realistic finite element model of the human thorax. Coil electrodes (Endotak DSP, model 125, Guidant/CPI) were placed in the RV apex along the lateral wall (RV), withdrawn 10 mm away from the RV apex along the lateral wall (RVprox), in the RV apex along the anterior septum (RVseptal), and in the SVC. An active pulse generator (can) was placed in the subcutaneous prepectoral space. Five electrode configurations were studied: RV-->SVC, RVprox-->SVC, RVSEPTAL-->SVC, RV-->Can, and RV-->SVC + Can. DFTs are defined as the energy required to produce a potential gradient of at least 5 V/cm in 95% of the ventricular myocardium. DFTs for RV-->SVC, RVprox-->SVC, RVseptal-->SVC, RV-->Can, and RV-->SVC + Can were 10, 16, 7, 9, and 6 J, respectively. The DFTs measured at each configuration fell within one standard deviation of the mean DFTs reported in clinical studies using the Endotak leads. The relative changes in DFT among electrode configurations also compared favorably. This computer model allows measurements of DFT or other defibrillation parameters with several different electrode configurations saving time and cost of clinical studies.
Optimal Sensor Placement for Measuring Physical Activity with a 3D Accelerometer
Boerema, Simone T.; van Velsen, Lex; Schaake, Leendert; Tönis, Thijs M.; Hermens, Hermie J.
2014-01-01
Accelerometer-based activity monitors are popular for monitoring physical activity. In this study, we investigated optimal sensor placement for increasing the quality of studies that utilize accelerometer data to assess physical activity. We performed a two-staged study, focused on sensor location and type of mounting. Ten subjects walked at various walking speeds on a treadmill, performed a deskwork protocol, and walked on level ground, while simultaneously wearing five ProMove2 sensors with a snug fit on an elastic waist belt. We found that sensor location, type of activity, and their interaction-effect affected sensor output. The most lateral positions on the waist belt were the least sensitive for interference. The effect of mounting was explored, by making two subjects repeat the experimental protocol with sensors more loosely fitted to the elastic belt. The loose fit resulted in lower sensor output, except for the deskwork protocol, where output was higher. In order to increase the reliability and to reduce the variability of sensor output, researchers should place activity sensors on the most lateral position of a participant's waist belt. If the sensor hampers free movement, it may be positioned slightly more forward on the belt. Finally, sensors should be fitted tightly to the body. PMID:24553085
On the placement of practice questions during study.
Weinstein, Yana; Nunes, Ludmila D; Karpicke, Jeffrey D
2016-03-01
Retrieval practice improves retention of information on later tests. A question remains: When should retrieval occur during learning-interspersed throughout study or at the end of each study period? In a lab experiment, an online experiment, and a classroom study, we aimed to determine the ideal placement (interspersed vs. at-the-end) of retrieval practice questions. In the lab experiment, 64 subjects viewed slides about APA style and answered short-answer practice questions about the content or restudied the slides (restudy condition). The practice questions either appeared 1 every 1-2 slides (interspersed condition), or all at the end of the presentation (at-the-end condition). One week later, subjects returned and answered the same questions on a final test. In the online experiment, 175 subjects completed the same procedure. In the classroom study, 62 undergraduate students took quizzes as part of class lectures. Short-answer practice questions appeared either throughout the lectures (interspersed condition) or at the end of the lectures (at-the-end condition). Nineteen days after the last quiz, students were given a surprise final test. Results from the 3 experiments converge in demonstrating an advantage for interspersing practice questions on the initial tests, but an absence of this advantage on the final test. (c) 2016 APA, all rights reserved).
Tho, Poh Chi; Mordiffi, Siti; Ang, Emily; Chen, Helen
2011-03-01
Nasogastric (NG) tube is a device passed through the gastrointestinal tract of patients for the purpose of feeding, gastric decompression and medication administration. However, a small risk involved in the process is that the tube may be misplaced into the trachea during insertion or may get displaced at a later stage, leading to disastrous results. Recent adverse incidences arising out of the misplacement of NG tube raised concerns among the nursing and medical community and the Patient Safety Officer of the hospital. The Evidence Based Nursing Unit, in collaboration with some of the key nursing leaders in nursing administration, was tasked to explore and institute the current best practice in confirming the correct placement of NG tube. The aim of this project was to institute the best practice to confirm the correct placement of NG tube in patients in an acute care hospital setting. The project comprised of a few stages. The first stage involved reviewing the existing recommendations and guidelines on the methods for checking correct NG tube placement. The second stage involved incorporation of the change of practice into the clinical setting. The final stage was to monitor and evaluate the impact of the new practice on the patients, nurses and other healthcare professionals. Evidence search from guidelines and journals supported the test that used pH indicator instead of the litmus test. There is no evidence that supports the method of auscultation and bubbling to confirm correct NG tube placement in the absence of aspirate. Radiology remains the 'gold standard' for checking correct NG tube placement. The revised method of NG tube placement and workflow was incorporated in the revised Standard Operating Procedures. A total of 17 roadshows were conducted to create awareness regarding the new method amongst the nurses, and the implementation of the revised method and workflow was commenced on 3 November 2008. The initial audit conducted 1 month after the practice change was implemented reported 26 (50%) observations of NG tube feeding in 26 audit wards. The key areas of practice change in feeding when tube placement was confirmed (84.6%) and proper testing of aspirate (76.9%) showed good compliance. The implementation of the change in the practice of confirming the correct placement of the NG tube in patients requires good coordination and a multidisciplinary team approach. © 2011 The Authors. International Journal of Evidence-Based Healthcare © 2011 The Joanna Briggs Institute.
Sirleo, Luigi; Innocenti, Massimo; Innocenti, Matteo; Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio
2018-02-01
To evaluate the feedback from post-operative three-dimensional computed tomography (3D-CT) on femoral tunnel placement in the learning process, to obtain an anatomic anterior cruciate ligament (ACL) reconstruction. A series of 60 consecutive patients undergoing primary ACL reconstruction using autologous hamstrings single-bundle outside-in technique were prospectively included in the study. ACL reconstructions were performed by the same trainee-surgeon during his learning phase of anatomic ACL femoral tunnel placement. A CT scan with dedicated tunnel study was performed in all patients within 48 h after surgery. The data obtained from the CT scan were processed into a three-dimensional surface model, and a true medial view of the lateral femoral condyle was used for the femoral tunnel placement analysis. Two independent examiners analysed the tunnel placements. The centre of femoral tunnel was measured using a quadrant method as described by Bernard and Hertel. The coordinates measured were compared with anatomic coordinates values described in the literature [deep-to-shallow distance (X-axis) 28.5%; high-to-low distance (Y-axis) 35.2%]. Tunnel placement was evaluated in terms of accuracy and precision. After each ACL reconstruction, results were shown to the surgeon to receive an instant feedback in order to achieve accurate correction and improve tunnel placement for the next surgery. Complications and arthroscopic time were also recorded. Results were divided into three consecutive series (1, 2, 3) of 20 patients each. A trend to placing femoral tunnel slightly shallow in deep-to-shallow distance and slightly high in high-to-low distance was observed in the first and the second series. A progressive improvement in tunnel position was recorded from the first to second series and from the second to the third series. Both accuracy (+52.4%) and precision (+55.7%) increased from the first to the third series (p < 0.001). Arthroscopic time decreased from a mean of 105 min in the first series to 57 min in the third series (p < 0.001). After 50 ACL reconstructions, a satisfactory anatomic femoral tunnel was reached. Feedback from post-operative 3D-CT is effective in the learning process to improve accuracy and precision of femoral tunnel placement in order to obtain anatomic ACL reconstruction and helps to reduce also arthroscopic time and learning curve. For clinical relevance, trainee-surgeons should use feedback from post-operative 3DCT to learn anatomic ACL femoral tunnel placement and apply it appropriately. Consecutive case series, Level IV.
Roycewicz, Peter S; Malamy, Jocelyn E
2014-05-01
Plants adapt to their unique soil environments by altering the number and placement of lateral roots post-embryonic. Mutants were identified in Arabidopsis thaliana that exhibit increased lateral root formation. Eight mutants were characterized in detail and were found to have increased lateral root formation due to at least three distinct mechanisms. The causal mutation in one of these mutants was found in the XEG113 gene, recently shown to be involved in plant cell wall biosynthesis. Lateral root primordia initiation is unaltered in this mutant. In contrast, synchronization of lateral root initiation demonstrated that mutation of XEG113 increases the rate at which lateral root primordia develop and emerge to form lateral roots. The effect of the XEG113 mutation was specific to the root system and had no apparent effect on shoot growth. Screening of 17 additional cell wall mutants, altering a myriad of cell wall components, revealed that many (but not all) types of cell wall defects promote lateral root formation. These results suggest that proper cell wall biosynthesis is necessary to constrain lateral root primordia emergence. While previous reports have shown that lateral root emergence is accompanied by active remodelling of cell walls overlying the primordia, this study is the first to demonstrate that alteration of the cell wall is sufficient to promote lateral root formation. Therefore, inherent cell wall properties may play a previously unappreciated role in regulation of root system architecture.
A new lineage of Cretaceous jewel wasps (Chalcidoidea: Diversinitidae).
Haas, Michael; Burks, Roger A; Krogmann, Lars
2018-01-01
Jewel wasps (Hymenoptera: Chalcidoidea) are extremely species-rich today, but have a sparse fossil record from the Cretaceous, the period of their early diversification. Three genera and three species, Diversinitus attenboroughi gen. & sp. n. , Burminata caputaeria gen. & sp. n. and Glabiala barbata gen. & sp. n. are described in the family Diversinitidae fam. n., from Lower Cretaceous Burmese amber. Placement in Chalcidoidea is supported by the presence of multiporous plate sensilla on the antennal flagellum and a laterally exposed prepectus. The new taxa can be excluded from all extant family level chalcidoid lineages by the presence of multiporous plate sensilla on the first flagellomere in both sexes and lack of any synapomorphies. Accordingly, a new family is proposed for the fossils and its probable phylogenetic position within Chalcidoidea is discussed. Morphological cladistic analyses of the new fossils within the Heraty et al. (2013) dataset did not resolve the phylogenetic placement of Diversinitidae, but indicated its monophyly. Phylogenetically relevant morphological characters of the new fossils are discussed with reference to Cretaceous and extant chalcidoid taxa. Along with mymarid fossils and a few species of uncertain phylogenetic placement, the newly described members of Diversinitidae are among the earliest known chalcidoids and advance our knowledge of their Cretaceous diversity.
Dragonas, Panagiotis; Palin, Charles; Khan, Saba; Gajendrareddy, Praveen K; Weiner, Whitney D
2017-10-01
This case report aims to describe in detail a complication associated with resorption of regenerated bone following implant placement and ridge augmentation using recombinant human bone morphogenic protein-2 (rhBMP-2) in combination with allograft and xenograft. Bilateral maxillary sinus and ridge augmentation procedures were completed using rhBMP-2 combined with allograft and xenograft. Five months later, significant bone augmentation was achieved, which allowed for the placement of 4 implants. Upon stage 2 surgery, significant dehiscence was noted in all implants. Treatment steps to address this complication included implant removal, guided bone regeneration with xenograft only, and placement of new implants followed by soft-tissue grafting. At the time of publication, this patient is status 1½ years post case completion with maintenance of therapy outcomes. Off-label use of rhBMP-2 has gained significant acceptance in implant dentistry. However, there is limited evidence regarding the bone maturation process when rhBMP-2 is combined with other biomaterials. More research may be needed regarding the timing and process of bone healing in the presence of rhBMP-2, in an effort to avoid surgical complications.
Ambulatory estimation of foot placement during walking using inertial sensors.
Martin Schepers, H; van Asseldonk, Edwin H F; Baten, Chris T M; Veltink, Peter H
2010-12-01
This study proposes a method to assess foot placement during walking using an ambulatory measurement system consisting of orthopaedic sandals equipped with force/moment sensors and inertial sensors (accelerometers and gyroscopes). Two parameters, lateral foot placement (LFP) and stride length (SL), were estimated for each foot separately during walking with eyes open (EO), and with eyes closed (EC) to analyze if the ambulatory system was able to discriminate between different walking conditions. For validation, the ambulatory measurement system was compared to a reference optical position measurement system (Optotrak). LFP and SL were obtained by integration of inertial sensor signals. To reduce the drift caused by integration, LFP and SL were defined with respect to an average walking path using a predefined number of strides. By varying this number of strides, it was shown that LFP and SL could be best estimated using three consecutive strides. LFP and SL estimated from the instrumented shoe signals and with the reference system showed good correspondence as indicated by the RMS difference between both measurement systems being 6.5 ± 1.0 mm (mean ± standard deviation) for LFP, and 34.1 ± 2.7 mm for SL. Additionally, a statistical analysis revealed that the ambulatory system was able to discriminate between the EO and EC condition, like the reference system. It is concluded that the ambulatory measurement system was able to reliably estimate foot placement during walking. Copyright © 2010 Elsevier Ltd. All rights reserved.
Miyawaki, Christina E
2017-03-01
Challenges of filial caregiving practices by 1st-generation immigrants due to differences in caregiving values between their home and host countries are well documented. This study explored the filial responsibility of later generation Japanese American caregivers of older adults. Acculturation and filial responsibility were measured using the Suinn-Lew Asian Self Identity Acculturation scale and Filial Values Index, respectively. A qualitative interview guide was developed using Gordon's assimilation theory, and 21 caregivers ( M age = 68 years, 86% female, seven in each generation) were interviewed. Despite the 3rd-generation caregivers' high acculturation level, their filial responsibility scores remained high. Qualitative interviews also revealed later generation caregivers' strong filial responsibility and continued caregiving involvement. Unexpectedly, caregivers' own future expectancy of care included placement in mainstream residential facilities rather than ethnic-specific settings. Findings point to the need to develop caregiver services that consider later generation caregivers' culture and level of assimilation.
Mathematical model of carotid artery for stent placement
NASA Astrophysics Data System (ADS)
Rahman, Tengku Husna Tengku Abdul; Din, Ummul Khair Salma; Ahmad, Rokiah @ Rozita
2016-11-01
The carotid artery stenting is one of the methods used to reduce the effect of artherosclerosis which caused by the thickening of the artery wall. In most of the studies, the measure of wall elasticity, shear stress and the blood pressure through the blood flow were considered. The aim of this study is to determine the position to place the stent inside the carotid artery. A mathematical model is reconstructed to determine the suitable location of the stent in the carotid artery. Throughout the study, differences in fluid flow between a normal carotid artery wall and stenosed carotid artery wall are investigated. Since the existence of the stenosis provides a resistance in the flow, it is important to identify the right position to place the stent. The stent will be placed in the position where stenosis exists to ease the blood to flow normally. Later after the stent placement, the blood flow normally through the blood vessel.
An overview of the genus Glyphium and its phylogenetic placement in Patellariales
Boehm, Eric W.A.; Marson, Guy; Mathiassen, Geir H.; Gardiennet, Alain; Schoch, Conrad L.
2015-01-01
Glyphium encompasses species with erect, carbonaceous ligulate to dolabrate ascomata that are strongly laterally compressed and dehisce along a longitudinal slit. The five currently recognized members of the genus are separated primarily by whether the ascospores disassociate into part-spores within the ascus. Glyphium has traditionally been placed in Mytilinidiaceae (Mytilinidiales, Pleosporomycetidae, Dothideomycetes). The present study, based on freshly collected material of G. elatum and G. grisonense, was initiated to determine the phylogenetic placement of Glyphium. Phylogenies inferred from the analysis of sequences of six gene regions (nuLSU, nuSSU, mtSSU, TEF1, RPB1, RPB2) derived from six accessions indicate that Glyphium belongs to Patellariales (Pleosporomycetidae, Dothideomycetes) . Our phylogenies also support the phylogenetic relationship of Patellaria and Hysteropatella within this order. The nomenclatural history of Glyphium is summarized and a key to species is provided. PMID:25661715
Effective Endovascular Stenting of Malignant Portal Vein Obstruction in Pancreatic Cancer
Ellis, Christian M.; Shenoy, Sadashiv; Litwin, Alan; Soehnlein, Stephanie; Gibbs, John F.
2009-01-01
We report herein the case of a patient successfully treated by transhepatic portal venous stent placement for malignant portal vein obstruction with associated gastric and small bowel varices and repeated gastrointestinal bleeding. CT angiography and portography showed severe portal vein obstruction from recurrent pancreatic cancer 15 months following pancreaticoduodenectomy with tumor encasement and dilated collateral veins throughout the gastric and proximal small bowel wall as the suspected cause of the GI bleeding. Successful transhepatic endovascular stent placement of the splenic vein at the portal vein confluence followed by balloon dilation was performed with immediate decompression of the gastric and small bowel varices and relief of GI hemorrhage in this patient until his death four months later. The treatment for patients with this dilemma can prove to be difficult, but as we have shown endovascular stenting of the portal system is an effective treatment option. PMID:19826629
Effective endovascular stenting of malignant portal vein obstruction in pancreatic cancer.
Ellis, Christian M; Shenoy, Sadashiv; Litwin, Alan; Soehnlein, Stephanie; Gibbs, John F
2009-01-01
We report herein the case of a patient successfully treated by transhepatic portal venous stent placement for malignant portal vein obstruction with associated gastric and small bowel varices and repeated gastrointestinal bleeding. CT angiography and portography showed severe portal vein obstruction from recurrent pancreatic cancer 15 months following pancreaticoduodenectomy with tumor encasement and dilated collateral veins throughout the gastric and proximal small bowel wall as the suspected cause of the GI bleeding. Successful transhepatic endovascular stent placement of the splenic vein at the portal vein confluence followed by balloon dilation was performed with immediate decompression of the gastric and small bowel varices and relief of GI hemorrhage in this patient until his death four months later. The treatment for patients with this dilemma can prove to be difficult, but as we have shown endovascular stenting of the portal system is an effective treatment option.
Magrin, Gabriel Leonardo; Sigua-Rodriguez, Eder Alberto; Goulart, Douglas Rangel; Asprino, Luciana
2015-01-01
The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement. PMID:26966469
Peris-Celda, Maria; Graziano, Francesca; Russo, Vittorio; Mericle, Robert A; Ulm, Arthur J
2013-11-01
Foramen ovale (FO) puncture allows for trigeminal neuralgia treatment, FO electrode placement, and selected biopsy studies. The goals of this study were to demonstrate the anatomical basis of complications related to FO puncture, and provide anatomical landmarks for improvement of safety, selective lesioning of the trigeminal nerve (TN), and optimal placement of electrodes. Both sides of 50 dry skulls were studied to obtain the distances from the FO to relevant cranial base references. A total of 36 sides from 18 formalin-fixed specimens were dissected for Meckel cave and TN measurements. The best radiographic projection for FO visualization was assessed in 40 skulls, and the optimal trajectory angles, insertion depths, and topographies of the lesions were evaluated in 17 specimens. In addition, the differences in postoperative pain relief after the radiofrequency procedure among different branches of the TN were statistically assessed in 49 patients to determine if there was any TN branch less efficiently targeted. Most severe complications during FO puncture are related to incorrect needle placement intracranially or extracranially. The needle should be inserted 25 mm lateral to the oral commissure, forming an approximately 45° angle with the hard palate in the lateral radiographic view, directed 20° medially in the anteroposterior view. Once the needle reaches the FO, it can be advanced by 20 mm, on average, up to the petrous ridge. If the needle/radiofrequency electrode tip remains more than 18 mm away from the midline, injury to the cavernous carotid artery is minimized. Anatomically there is less potential for complications when the needle/radiofrequency electrode is advanced no more than 2 mm away from the clival line in the lateral view, when the needle pierces the medial part of the FO toward the medial part of the trigeminal impression in the petrous ridge, and no more than 4 mm in the lateral part. The 40°/45° inferior transfacial-20° oblique radiographic projection visualized 96.2% of the FOs in dry skulls, and the remainder were not visualized in any other projection of the radiograph. Patients with V1 involvement experienced postoperative pain more frequently than did patients with V2 or V3 involvement. Anatomical targeting of V1 in specimens was more efficiently achieved by inserting the needle in the medial third of the FO; for V2 targeting, in the middle of the FO; and for V3 targeting, in the lateral third of the FO. Knowledge of the extracranial and intracranial anatomical relationships of the FO is essential to understanding and avoiding complications during FO puncture. These data suggest that better radiographic visualization of the FO can improve lesioning accuracy depending on the part of the FO to be punctured. The angles and safety distances obtained may help the neurosurgeon minimize complications during FO puncture and TN lesioning.
Rajasekaran, S; Bhushan, Manindra; Aiyer, Siddharth; Kanna, Rishi; Shetty, Ajoy Prasad
2018-01-09
To develop a classification based on the technical complexity encountered during pedicle screw insertion and to evaluate the performance of AIRO ® CT navigation system based on this classification, in the clinical scenario of complex spinal deformity. 31 complex spinal deformity correction surgeries were prospectively analyzed for performance of AIRO ® mobile CT-based navigation system. Pedicles were classified according to complexity of insertion into five types. Analysis was performed to estimate the accuracy of screw placement and time for screw insertion. Breach greater than 2 mm was considered for analysis. 452 pedicle screws were inserted (T1-T6: 116; T7-T12: 171; L1-S1: 165). The average Cobb angle was 68.3° (range 60°-104°). We had 242 grade 2 pedicles, 133 grade 3, and 77 grade 4, and 44 pedicles were unfit for pedicle screw insertion. We noted 27 pedicle screw breach (medial: 10; lateral: 16; anterior: 1). Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Average screw insertion time was 1.76 ± 0.89 min. After accounting for planned breach, the effective breach rate was 3.8% resulting in 96.2% accuracy for pedicle screw placement. This classification helps compare the accuracy of screw insertion in range of conditions by considering the complexity of screw insertion. Considering the clinical scenario of complex pedicle anatomy in spinal deformity AIRO ® navigation showed an excellent accuracy rate of 96.2%.
Fox-Alvarez, W Alexander; Case, J Brad; Cooke, Kirsten L; Garcia-Pereira, Fernando L; Buckley, Gareth J; Monnet, Eric; Toskich, Beau B
2016-07-01
OBJECTIVE To evaluate a percutaneous, continuous gastric decompression technique for dogs involving a temporary T-fastener gastropexy and self-retaining decompression catheter. ANIMALS 6 healthy male large-breed dogs. PROCEDURES Dogs were anesthetized and positioned in dorsal recumbency with slight left-lateral obliquity. The gastric lumen was insufflated endoscopically until tympany was evident. Three T-fasteners were placed percutaneously into the gastric lumen via the right lateral aspect of the abdomen, caudal to the 13th rib and lateral to the rectus abdominis muscle. Through the center of the T-fasteners, a 5F locking pigtail catheter was inserted into the gastric lumen and attached to a device measuring gas outflow and intragastric pressure. The stomach was insufflated to 23 mm Hg, air was allowed to passively drain from the catheter until intraluminal pressure reached 5 mm Hg for 3 cycles, and the catheter was removed. Dogs were hospitalized and monitored for 72 hours. RESULTS Mean ± SD catheter placement time was 3.3 ± 0.5 minutes. Mean intervals from catheter placement to a ≥ 50% decrease in intragastric pressure and to ≤ 6 mm Hg were 2.1 ± 1.3 minutes and 8.4 ± 5.1 minutes, respectively. After catheter removal, no gas or fluid leakage at the catheter site was visible laparoscopically or endoscopically. All dogs were clinically normal 72 hours after surgery. CONCLUSIONS AND CLINICAL RELEVANCE The described technique was performed rapidly and provided continuous gastric decompression with no evidence of postoperative leakage in healthy dogs. Investigation is warranted to evaluate its effectiveness in dogs with gastric dilatation-volvulus.
Resident accuracy of joint line palpation using ultrasound verification.
Rho, Monica E; Chu, Samuel K; Yang, Aaron; Hameed, Farah; Lin, Cindy Yuchin; Hurh, Peter J
2014-10-01
To determine the accuracy of knee and acromioclavicular (AC) joint line palpation in Physical Medicine and Rehabilitation (PM&R) residents using ultrasound (US) verification. Cohort study. PM&R residency program at an academic institution. Twenty-four PM&R residents participating in a musculoskeletal US course (7 PGY-2, 8 PGY-3, and 9 PGY4 residents). Twenty-four PM&R residents participating in an US course were asked to palpate the AC joint and lateral joint line of the knee in a female and male model before the start of the course. Once the presumed joint line was localized, the residents were asked to tape an 18-gauge, 1.5-inch, blunt-tip needle parallel to the joint line on the overlying skin. The accuracy of needle placement over the joint line was verified using US. US verification of correct needle placement over the joint line. Overall AC joint palpation accuracy was 16.7%, and knee lateral joint line palpation accuracy was 58.3%. Based on the resident level of education, using a value of P < .05, there were no statistically significant differences in the accuracy of joint line palpation. Residents in this study demonstrate poor accuracy of AC joint and lateral knee joint line identification by palpation, using US as the criterion standard for verification. There were no statistically significant differences in the accuracy rates of joint line palpation based on resident level of education. US may be a useful tool to use to advance the current methods of teaching the physical examination in medical education. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Malham, Gregory M; Parker, Rhiannon M
2018-04-01
OBJECTIVE Image guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors' early experience with the use of SpineMask for "K-wireless" placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion. METHODS Forty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle. RESULTS Fourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision. CONCLUSIONS The noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.
Stainless hooks to bond lower lingual retainer.
Durgekar, Sujala G; Nagaraj, K
2011-01-01
We introduced a simple and economical technique for precise placement of lower lingual retainers. Two stainless steel hooks made of 0.6mm wire are placed interdentally in the embrasure area between canine and lateral incisor bilaterally to lock the retainer wire in the correct position. Etch, rinse and dry the enamel surfaces with the retainer passively in place, then bond the retainer with light-cured adhesive. Hooks are simple to fabricate and eliminate the need for a transfer tray.
Kassam, A M; Tillotson, L; Schranz, P J; Mandalia, V I
2015-01-01
The aim of the study is to show, on an MRI scan, that the posterior border of the anterior horn of the lateral meniscus (AHLM) could guide tibial tunnel position in the sagittal plane and provide anatomical graft position. One hundred MRI scans were analysed with normal cruciate ligaments and no evidence of meniscal injury. We measured the distance between the posterior border of the AHLM and the midpoint of the ACL by superimposing sagittal images. The mean distance between the posterior border of the AHLM and the ACL midpoint was -0.1mm (i.e. 0.1mm posterior to the ACL midpoint). The range was 5mm to -4.6mm. The median value was 0.0mm. 95% confidence interval was from -0.5 to 0.3mm. A normal, parametric distribution was observed and Intra- and inter-observer variability showed significant correlation (p<0.05) using Pearsons Correlation test (intra-observer) and Interclass correlation (inter-observer). Using the posterior border of the AHLM is a reproducible and anatomical marker for the midpoint of the ACL footprint in the majority of cases. It can be used intra-operatively as a guide for tibial tunnel insertion and graft placement allowing anatomical reconstruction. There will inevitably be some anatomical variation. Pre-operative MRI assessment of the relationship between AHLM and ACL footprint is advised to improve surgical planning. Level 4.
Lindsey, Derek P; Perez-Orribo, Luis; Rodriguez-Martinez, Nestor; Reyes, Phillip M; Newcomb, Anna; Cable, Alexandria; Hickam, Grace; Yerby, Scott A; Crawford, Neil R
2014-01-01
Introduction Sacroiliac (SI) joint pain has become a recognized factor in low back pain. The purpose of this study was to investigate the effect of a minimally invasive surgical SI joint fusion procedure on the in vitro biomechanics of the SI joint before and after cyclic loading. Methods Seven cadaveric specimens were tested under the following conditions: intact, posterior ligaments (PL) and pubic symphysis (PS) cut, treated (three implants placed), and after 5,000 cycles of flexion–extension. The range of motion (ROM) in flexion–extension, lateral bending, and axial rotation was determined with an applied 7.5 N · m moment using an optoelectronic system. Results for each ROM were compared using a repeated measures analysis of variance (ANOVA) with a Holm–Šidák post-hoc test. Results Placement of three fusion devices decreased the flexion–extension ROM. Lateral bending and axial rotation were not significantly altered. All PL/PS cut and post-cyclic ROMs were larger than in the intact condition. The 5,000 cycles of flexion–extension did not lead to a significant increase in any ROMs. Discussion In the current model, placement of three 7.0 mm iFuse Implants significantly decreased the flexion–extension ROM. Joint ROM was not increased by 5,000 flexion–extension cycles. PMID:24868175
Traube, Dorian E; Yarnell, Lisa M; Schrager, Sheree M
2016-02-01
The current study extended limited prior work on polysubstance use among youth in the child welfare system (CWS) by addressing their potentially greater risk of engaging in polysubstance use, the causes of interpersonal variation in use, and changes in use over time, particularly at later points of involvement in the CWS. Using longitudinal data from the National Survey of Child and Adolescent Well-Being (n=1,178), a series of time-invariant and time-varying demographic and contextual factors were explored to assess their role both overall and at unique points of involvement in the CWS. A series of unconditional and conditional curve-of-factor models were estimated and results indicated that time-invariant characteristics of ethnicity and gender were not related to polysubstance use. Time-variant characteristics of age and placement were associated with polysubstance use and highlighted the dynamic nature of age as a risk factor. Out-of-home placement was protective against later substance use for youth who had been removed from contexts with their original caretaker where there were higher levels of reported violence. Our results suggest that in the child welfare population, the modeling of multiple substances rather than a single substance in isolation is more informative because it yields information on the confluence of behaviors that tend to occur and evolve together. Copyright © 2015 Elsevier Ltd. All rights reserved.
Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A
2005-11-01
The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA <125 degrees . Mean adjusted TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was <125 degrees than if NSA was >125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA <125 degrees leads to poorer lag screw placement than if NSA >125 degrees and caution is advocated when using this device in such cases.
Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V
2016-11-01
The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.
Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim
2017-05-01
Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.
Delk, Katie W; Wack, Raymund F; Burgdorf-Moisuk, Anne; Palm, Carrie A; Zwingenberger, Allison; Glaiberman, Craig B; Ferguson, Kenneth H; Culp, William T N
2015-01-01
A 15-year-old, 113 kg intact male Sumatran tiger (Panthera tigris sumatrae) was evaluated for weight loss, polydipsia, and intermittent hematuria. The tiger was immobilized for diagnostic testing including blood work, urinalysis, and abdominal ultrasound. Laboratory testing demonstrated macro- and microhematuria, azotemia, and an increased urine protein:creatinine ratio. Abdominal ultrasound revealed bilateral ureterolithiasis as well as hydronephrosis and ureteral dilation. Ultrasonography performed 5 months later revealed worsening of the right-sided hydronephrosis and hydroureter and a decrease in the severity of dilation on the left side presumably from passage of the left-sided ureteral calculi. Nephroureteral decompression via the placement of a stent was elected. A pigtail ureteral catheter (8.2 French diameter) was placed in the right ureter via an antegrade percutaneous approach utilizing ultrasound and fluoroscopic-guidance. Following stent placement, macrohematuria resolved although microhematuria was noted in opportunistic urine samples. Five months after stent placement, the azotemia had mildly progressed, the urine protein:creatinine ratio was improved, the right hydronephrosis and hydroureter had completely resolved, and the ureteral stent remained in the appropriate position. The tiger had clinically improved with a substantial increase in appetite, weight, and activity level. Ureteral stenting allowed for nephroureteral decompression in the captive large felid of this report, and no complications were encountered. Ureteral stenting provided a minimally invasive method of managing ureteral obstruction in this patient and could be considered in future cases due to the clinical improvement and low morbidity. © 2015 Wiley Periodicals, Inc.
Percutaneous insertion of a proximal humeral locking plate: an anatomic study.
Smith, Jason; Berry, Greg; Laflamme, Yves; Blain-Pare, Etienne; Reindl, Rudy; Harvey, Edward
2007-02-01
This cadaveric study sought to evaluate the feasibility of applying a locking proximal humerus plate with a novel minimally invasive technique. A unique pre-contoured locking plate was placed on cadaveric proximal humeri through a described minimally invasive approach. Proximity of the plate and screws to the axillary nerve and their respective surgical tracks were quantified. Safe screw hole placement with respect to the axillary nerve was determined. Risk of entrapment of the nerve beneath the plate was evaluated. Three of the holes near the middle of the locking plate consistently intersected the course of the axillary nerve and were unsafe for percutaneous placement of the screws. The axillary nerve could be palpated during the course of surgery and easily protected from injury. No entrapment of the axillary nerve occurred using this minimally invasive technique. The screw-in locking guide cannot be used with this technique as it caused tenting of the axillary nerve. Placement of a locking proximal humerus plate via a minimally invasive lateral trans-deltoid approach is safe if the locking screws are limited to superior and inferior holes. This can be done safely without entrapment of the axillary beneath the plate. Plate fixation of proximal humerus fractures may now be more desirable with the use of this approach.
Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT
2013-01-01
Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828
Sarubbo, S.; Latini, F.; Tugnoli, V.; Quatrale, R.; Granieri, E.; Cavallo, M. A.
2012-01-01
Object. We arranged a mini-invasive surgical approach for implantation of paddle electrodes for SCS under spinal anesthesia obtaining the best paddle electrode placement and minimizing patients' discomfort. We describe our technique supported by neurophysiological intraoperative monitoring and clinical results. Methods. 16 patients, affected by neuropathic pain underwent the implantation of paddle electrodes for spinal cord stimulation in lateral decubitus under spinal anesthesia. The paddle was introduced after flavectomy and each patient confirmed the correct distribution of paresthesias induced by intraoperative test stimulation. VAS and patients' satisfaction rate were recorded during the followup and compared to preoperative values. Results. No patients reported discomfort during the procedure. In all cases, paresthesias coverage of the total painful region was achieved, allowing the best final electrode positioning. At the last followup (mean 36.7 months), 87.5% of the implanted patients had a good rate of satisfaction with a mean VAS score improvement of 70.5%. Conclusions. Spinal cord stimulation under spinal anesthesia allows an optimal positioning of the paddle electrodes without any discomfort for patients or neurosurgeons. The best intraoperative positioning allows a better postoperative control of pain, avoiding the risk of blind placements of the paddle or further surgery for their replacement. PMID:22566761
Barstow, A; Bailey, J; Campbell, J; Harris, C; Weller, R; Pfau, T
2018-04-17
Both pleasure and competition horses regularly exercise on surfaces such as tarmac, gravel and turf during 'hacking'. Despite this, there is limited evidence relating to the effect of these surfaces upon foot-surface interaction. To investigate forelimb foot placement, hoof vibration and movement symmetry in pleasure horses on three commonly encountered hacking surfaces. Quantitative gait study in a convenience sample. Six horses regularly partaking in hacking exercise were ridden in walk and trot on all surfaces. Horses were equipped with one hoof-mounted, accelerometer and four body-mounted inertial measurement units (IMUs) to measure foot impact and movement symmetry. High-speed (400 FPS) video footage of foot-placement was acquired (dorsal, palmar, lateral views). Foot-impact and movement symmetry were analysed with a mixed effects model and Bowker symmetry tests for foot-placement analysis. Vibration power and frequency parameters increase as perceived surface firmness increases from grass, to gravel, to tarmac (P≤0.001). Vibration power parameters were consistently greater at trot compared with walk (P≤0.001), but the same was not true for vibration frequency (P≥0.2). Greatest movement asymmetry was recorded during grass surface trotting. No significant difference in foot-placement was detected between the three surfaces. This was a field study using three commonly encountered hacking surfaces. Surface properties change easily with water content and temperature fluctuations so care must be taken when considering other similar surfaces, especially at different times of the year. Six leisure horses were used so the results may not be representative of horses of all types. Vibration parameters generally increase as perceived surface firmness increases. Increasing speed alters vibration power but not frequency. Further investigations are required to determine the role that this may play in the development of musculoskeletal disease in horses. © 2018 EVJ Ltd.
Alonso, Fernando; Iwanaga, Joe; Chapman, Jens R; Oskouian, Rod J; Tubbs, R Shane
2017-08-01
Type 2 odontoid fractures are the most common cervical fractures among the elderly. Neurologic deficit is usually caused by myelopathy as a result of posterior dens migration. Direct anterior screw placement provides stabilization and can preserve C1-C2 movement. The presence of a bony excrescence on the anterior superior tip of the dens may lead to placement of a screw of incorrect length. Twenty C2 dry specimens were examined for the presence of a corona dentis, which is a bony excrescence in the coronal plane near the apex of the dens. When identified, measurements of the corona dentis were performed using calipers and a ruler. In addition, anteroposterior (AP) and lateral fluoroscopy was performed on all specimens found to have a corona dentis. A corona dentis was found on 20% of our C2 specimens and had an average width of 9 mm and an average height of 4.5 mm. The average width of the dens did not vary as the normal tip of the dens transitioned into the coronae. In no specimen did the corona dentis seem to be composed of trabecular bone and it was seen as a superior projection of cortical bone on fluoroscopy. On fluoroscopy, the corona dentis could be identified on a true AP projection. In angulated AP views, fluoroscopic images overestimated the length of the corona dentis. We describe a new entity termed the corona dentis because of its crownlike feature. It is a superior cortical bone protrusion and should be noted as a variant of the dens during anterior odontoid screw placement. Its propensity to increase the height of the dens markedly can lead to higher rates of neurologic deficits during type 2 odontoid fractures if not appreciated. A true AP view is critical for correct screw size placement. Copyright © 2017 Elsevier Inc. All rights reserved.
Anaizi, Amjad Nasr; Kalhorn, Christopher; McCullough, Michael; Voyadzis, Jean-Marc; Sandhu, Faheem A
2015-01-01
A retrospective case series evaluating the use of fiducial markers with subsequent computed tomography (CT) or CT myelography for intraoperative localization. To evaluate the safety and utility of preoperative fiducial placement, confirmed with CT myelography, for intraoperative localization of thoracic spinal levels. Thoracic spine surgery is associated with serious complications, not the least of which is the potential for wrong-level surgery. Intraoperative fluoroscopy is often used but can be unreliable due to the patient's body habitus and anatomical variation. Sixteen patients with thoracic spine pathology requiring surgical intervention underwent preoperative fiducial placement at the pedicle of the level of interest in the interventional radiology suite. CT or CT myelogram was then done to evaluate fiducial location relative to the level of pathology. Surgical treatment followed at a later date in all patients. All patients underwent preoperative fiducial placement and CT or CT myelography, which was done on an outpatient basis in 14 of the 16 patients. Intraoperatively, fiducial localization was easily and quickly done with intraoperative fluoroscopy leading to correct localization of spinal level in all cases. All patients had symptomatic improvement following surgery. There were no complications from preoperative localization or operative intervention. Preoperative placement of fiducial markers confirmed with a CT or CT myelogram allows for reliable and fast intraoperative localization of the spinal level of interest with minimal risks and potential complications to the patient. In most cases, a noncontrast CT should be sufficient. This should be an equally reliable means of localization while further decreasing potential for complications. CT myelography should be reserved for pathology that is not evident on noncontrast CT. Accuracy of localization is independent of variations in rib number or vertebral segmentation. The technique is a safe, reliable, and rapid means of localizing spinal level during surgery. Georg Thieme Verlag KG Stuttgart · New York.
Duraski, Sylvia A; Sayyad, Anjum
2018-04-01
This article details an unreported potential cause of withdrawal symptoms in a patient with cerebral palsy who experienced intrathecal baclofen withdrawal shortly after placement of a baclofen pump with subsequent refill with Gablofen. Initial implantation of the baclofen pump with Lioresal occurred after a successful hospital trial of intrathecal injection via lumbar puncture. However, later, the patient did experience signs and symptoms of baclofen withdrawal after a pump refill was performed with Gablofen.
Beginning hip arthroscopy: indications, positioning, portals, basic techniques, and complications.
Smart, L Ryan; Oetgen, Matthew; Noonan, Benjamin; Medvecky, Michael
2007-12-01
Hip arthroscopy is becoming increasingly popular for the diagnosis and treatment of hip pathology, and the indications continue to evolve. The two most common approaches are the supine and lateral decubitus position. Both approaches can be performed effectively; however, each approach has its own benefits and drawbacks. In this review we will describe the indications for hip arthroscopy, the pros and cons of each approach, and the necessary equipment, portals, portal placement, commercially available distraction devices, and complications.
Share Your Opinion With Other Eos Readers
NASA Astrophysics Data System (ADS)
Narasimhan, T. N.
2006-11-01
Earlier this year, Robert Kitchen (Eos, 87(24), 235, 2006) drew attention to declining interest in Earth science education in public schools. The reason for a lack of interest in teaching Earth sciences in public schools may involve more than just the attitudes of parents who may wish for their children a better preparation for advanced placement courses later on. Part of the problem may lie with our present mind-set that technology can solve all the world's problems, from poverty, to better health, and to prosperity.
Which newborns in New York City are at risk for special education placement?
Goldberg, D; McLaughlin, M; Grossi, M; Tytun, A; Blum, S
1992-03-01
In this study of 162 third graders in New York City public schools, we found that slightly over half of the children in special education were males who had Medicaid coverage at birth and mothers with medical conditions or adverse health habits noted on the birth certificate; two thirds of the children with this combination of characteristics actually were placed in special education. These findings suggest that newborns at risk for later learning disabilities can be targeted to receive preventive interventions.
Yoshikawa, Yukihiro; Yoshikawa, Masato; Kawabata, Ryohei; Yoshida, Yuta; Kawada, Masahiro; Yasuyama, Akinobu; Watase, Chikashi; Koga, Chikato; Hitora, Toshiki; Murakami, Masahiro; Hirota, Masaki; Ikenaga, Masakazu; Shimizu, Junzo; Hasegawa, Junichi
2015-11-01
A 68-year-old man underwent esophagectomy for early esophageal cancer. Postoperative upper gastrointestinal series and esophagogastroduodenoscopy showed gastric tube stenosis. To improve passage, a removable self-expandable metallic stent (SEMS) was placed across the stenotic lesion. Two weeks later, the stent was removed, and passage through the gastric tube improved. The patient has no symptoms of stenosis. A removable SEMS could be an option for the treatment of gastric tube stenosis after esophagectomy.
IMAGING DIAGNOSIS-MAGNETIC RESONANCE IMAGING OF A NEURONAL HETEROTOPIA IN THE BRAIN OF A CAT.
DeJesus, Antonia; Turek, Bradley J; Galban, Evelyn; Suran, Jantra Ngosuwan
2018-03-01
A domestic shorthair kitten was presented for evaluation and further treatment of seizures. Magnetic resonance imaging of the brain revealed a large multilobulated mass in the third ventricle extending into the right lateral ventricle with secondary obstructive hydrocephalus. The mass was homogeneously isointense to gray matter on T2W, T2-FLAIR, T2 * W, T1W, and ADC images, and hyperintense on DW-EPI. There was no appreciable contrast enhancement. Seizures were managed medically and with subsequent ventriculoperitoneal shunt placement. Clinical status later deteriorated and the cat was euthanized. Histopathology confirmed that the mass was the result of neuronal heterotopia. To the authors' knowledge this is the first report of neuronal heterotopia in a cat. © 2016 American College of Veterinary Radiology.
Ashfaq, Awais; Chapital, Alyssa B
2015-07-06
Peptic ulcer disease has been a major problem since the turn of this century with high morbidity and mortality. Perforation is less common, with an estimated incidence of 7-10 per 100 000. We present a young woman with rheumatoid arthritis presenting with anaemia. On work up, she was found to have a chronic abdominal abscess secondary to subclinical perforation of a duodenal ulcer. After undergoing percutaneous drainage, she became haemodynamically unstable and was taken for surgical washout and jejunostomy tube placement. A week later she had a decrease in the size of the abscess and was discharged home with drain and tube feeds. At her follow-up a few weeks later, she was tolerating goal tube feeds. 2015 BMJ Publishing Group Ltd.
Stereological analysis of gravitropism in protonemata of the moss Ceratodon
NASA Technical Reports Server (NTRS)
Walker, L. M.; Sack, F. D.
1997-01-01
Apical cells of dark-grown protonemata of the moss Cerotodon purpureus are negatively gravitropic. Previous light microscopy has shown that reorientation to the horizontal induces amyloplast sedimentation and redistribution of microtubules. To determine whether other components become redistributed laterally or axially, the apical 35 micrometers of both vertical and horizontal apical cells were compared stereologically using transmission electron microscopy. Reorientation to the horizontal changed the longitudinal distributions of tubular ER, Golgi stacks, and vesicles but not cisternal ER, mitochondria, and plastids. Only plastids showed a statistically significant lateral redistribution after horizontal placement. Qualitative examination of the sedimentation zone showed plastids sedimented close to peripherally located ER with vacuoles displaced above plastids. These results argue against a model where differential tip growth results from a redistribution of Golgi stacks or exocytic vesicles.
Integrated multiple patch-clamp array chip via lateral cell trapping junctions
NASA Astrophysics Data System (ADS)
Seo, J.; Ionescu-Zanetti, C.; Diamond, J.; Lal, R.; Lee, L. P.
2004-03-01
We present an integrated multiple patch-clamp array chip by utilizing lateral cell trapping junctions. The intersectional design of a microfluidic network provides multiple cell addressing and manipulation sites for efficient electrophysiological measurements at a number of patch sites. The patch pores consist of openings in the sidewall of a main fluidic channel, and a membrane patch is drawn into a smaller horizontal channel. This device geometry not only minimizes capacitive coupling between the cell reservoir and the patch channel, but also allows simultaneous optical and electrical measurements of ion channel proteins. Evidence of the hydrodynamic placement of mammalian cells at the patch sites as well as measurements of patch sealing resistance is presented. Device fabrication is based on micromolding of polydimethylsiloxane, thus allowing inexpensive mass production of disposable high-throughput biochips.
Miyawaki, Christina E.
2015-01-01
Challenges of filial caregiving practices by 1st-generation immigrants due to differences in caregiving values between their home and host countries are well documented. This study explored the filial responsibility of later generation Japanese American caregivers of older adults. Acculturation and filial responsibility were measured using the Suinn-Lew Asian Self Identity Acculturation scale and Filial Values Index, respectively. A qualitative interview guide was developed using Gordon’s assimilation theory, and 21 caregivers (M age = 68 years, 86% female, seven in each generation) were interviewed. Despite the 3rd-generation caregivers’ high acculturation level, their filial responsibility scores remained high. Qualitative interviews also revealed later generation caregivers’ strong filial responsibility and continued caregiving involvement. Unexpectedly, caregivers’ own future expectancy of care included placement in mainstream residential facilities rather than ethnicspecific settings. Findings point to the need to develop caregiver services that consider later generation caregivers’ culture and level of assimilation. PMID:25883044
Stephan, Carl N; Huang, Anne J R; Davidson, Paavi L
2009-03-01
Recently a small sampled cadaver study (n = 4) suggested that the human eyeballs are placed closer to the orbital roof and lateral orbital wall as first reported in the anatomical literature many years previously. This contrasts with central positioning of the eyeball within the orbit as advocated by the facial approximation literature. Given the limits of such small samples, this study re-examined globe position in nine new cadavers to help clarify which relationship is accurate. The results essentially confirm prior empirical findings except that the mean lateral divergences from the orbit center were found to be larger--the eyeball was found to be "displaced" 1.4 mm superiorly and 2.4 mm laterally. Medians calculated across all 13 cadavers from this study and the above-mentioned recent report refine these measurements to 1.4 and 2.3 mm respectively. Globe projection values were identical to those observed for living individuals (c. 16 mm).
Lateral retroperitoneal transpsoas interbody fusion in a patient with achondroplastic dwarfism.
Staub, Blake N; Holman, Paul J
2015-02-01
The authors present the first reported use of the lateral retroperitoneal transpsoas approach for interbody arthrodesis in a patient with achondroplastic dwarfism. The inherent anatomical abnormalities of the spine present in achondroplastic dwarfism predispose these patients to an increased incidence of spinal deformity as well as neurogenic claudication and potential radicular symptoms. The risks associated with prolonged general anesthesia and intolerance of significant blood loss in these patients makes them ideal candidates for minimally invasive spinal surgery. The patient in this case was a 51-year-old man with achondroplastic dwarfism who had a history of progressive claudication and radicular pain despite previous extensive lumbar laminectomies. The lateral retroperitoneal transpsoas approach was used for placement of interbody cages at L1/2, L2/3, L3/4, and L4/5, followed by posterior decompression and pedicle screw instrumentation. The patient tolerated the procedure well with no complications. Postoperatively his claudicatory and radicular symptoms resolved and a CT scan revealed solid arthrodesis with no periimplant lucencies.
Rosenthal, Natalie L.; Kobak, Roger
2012-01-01
Adolescents’ attachment hierarchies were assessed in a sample of 212 high school and 198 college students. The Important People Interview (IPI) differentiated attachment bonds from other supportive or affiliative relationships and indicated that adolescents show a hierarchical ordering of preferences for multiple attachment figures. Differences in the composition and structure of adolescents’ attachment hierarchies were found between the early high school (9th and 10th grades), later high school (11th and 12th grades), and college samples. In the college sample, romantic partners were placed in higher positions in adolescents’ hierarchies, fathers were placed in lower positions, and the structure of adolescents’ hierarchies were less differentiated than in the high school samples. Individual differences in the composition of adolescents’ hierarchies were associated with adjustment outcomes. Friends’ placement in higher positions and fathers’ exclusion from or placement in quaternary positions was associated with increased behavior problems. Findings demonstrate that the IPI provides a measure of adolescents’ attachment hierarchies that is sensitive to developmental stage and individual differences. PMID:22545000
Haskins, Anna R
2014-04-01
Though sociologists have examined how mass incarceration affects stratification, remarkably little is known about how it shapes educational disparities. Analyzing the Fragile Families Study and its rich paternal incarceration data, I ask whether black and white children with fathers who have been incarcerated are less prepared for school both cognitively and non-cognitively as a result, and whether racial and gendered disparities in incarceration help explain the persistence of similar gaps in educational outcomes and trajectories. Using a variety of estimation strategies, I show that experiencing paternal incarceration by age five is associated with lower non-cognitive school readiness. While the main effect of incarceration does not vary by race, boys with incarcerated fathers have substantially worse non-cognitive skills at school entry, impacting the likelihood of special education placement at age nine. Mass incarceration facilitates the intergenerational transmission of male behavioral disadvantage, and because of the higher exposure of black children to incarceration, it also plays a role in explaining the persistently low achievement of black boys.
Hu, Chen; Gong, Ting; Lin, Weimin; Yuan, Quan; Man, Yi
2017-10-01
To evaluate bone reconstruction and soft tissue reactions at immediate implants placed into intact sockets and those with buccal bone dehiscence defects. Fifty-nine internal connection implants from four different manufacturers were immediately placed in intact sockets(non-dehiscence group, n=40), and in alveoli with buccal bone dehiscence defects: 1) Group 1(n= N10), the defect depth measured 3-5 mm from the gingival margin. 2) Group 2(n=9), the depth ranged from 5mm to 7mm. The surrounding bony voids were grafted with deproteinized bovine bone mineral (DBBM) particles. Cone beam computed tomography(CBCT) was performed immediately after surgery (T1), and at 6 months later(T2). Radiographs were taken at prosthesis placement and one year postloading(T3). Soft tissue parameters were measured at baseline (T0), prosthesis placement and T3. No implants were lost during the observation period. For the dehiscence groups, the buccal bone plates were radiographically reconstructed to comparable horizontal and vertical bone volumes compared with the non-dehiscence group. Marginal bone loss occurred between the time of final restoration and 1-year postloading was not statistically different(P=0.732) between groups. Soft tissue parameters did not reveal inferior results for the dehiscence groups. Within the limitations of this study, flapless implant placement into compromised sockets in combination with DBBM grafting may be a viable technique to reconstitute the defected buccal bone plates due to space maintenance and primary socket closure provided by healing abutments and bone grafts. Immediate implants and DBBM grafting without using membranes may be indicated for sockets with buccal bone defects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wu, Xiao-Tian; Chen, Nong; Pan, Fu-Gen; Liu, Zuo-Qing; He, Xiao-Jian
2017-03-25
To investigate the feasibility and therapeutic effect of subcutaneous pedicle screw-rod system with modified placement in treatment of Tile B pelvic fractures. From June 2014 to August 2015, 14 patients with Tile B pelvic fractures were treated by subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle. There were 8 males and 6 females, aged from 23 to 65 years with an average of 42 years. Operative time, intraoperative blood loss, fracture healing and postoperative complication were observed and clinical effects were evaluated by Matta reduction standard and Majeed score. All patients were followed up from 8 to 15 months with an average of 10.5 months. Operative time was 25 to 45 min with an average of 32 min;intraoperative blood loss was 10 to 35 ml with an average of 18 ml. All fractures got primary healing and healed time was 9 to 14 weeks with an average of 12.5 weeks. No postoperative incision infection, internal fixation failure and ectopic ossification were found, 4 cases occurred unilateral lateral femoral cutaneous nerve injury and 1 case occurred unilateral femoral nerve paralysis, but all restored finally. According to Matta criteria, reduction was excellent in 7 cases, good in 5 cases, fair in 2 case. According to Majeed score system, the functional evaluation at last follow-up was excellent in 5 cases, good in 7 cases, fair in 2 cases with the average score of 81.50±8.05. Subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle have advantages of strong reduction, less trauma and complications, and is a promising surgical method in the treatment of Tile B pelvic fractures.
Kocaoglu, Baris; Ulku, Tekin Kerem; Sayilir, Safiye; Ozbaydar, Mehmet Ugur; Bayramoglu, Alp; Karahan, Mustafa
2017-10-01
The aim of our study was to evaluate the risk of medial glenoid perforation and possible injury to suprascapular nerve during arthroscopic SLAP repair using lateral transmuscular portal. Ten cadaveric shoulder girdles were isolated and drilled at superior glenoid rim from both anterior-superior portal (1 o'clock) and lateral transmuscular portal (12 o'clock) for SLAP repairs. Drill hole depth was determined by the manufacturer's drill stop (20 mm), and any subsequent drill perforations through the medial bony surface of the glenoid were directly confirmed by dissection. The bone tunnel depth and subsequent distance to the suprascapular nerve, scapular height and width, were compared for investigated locations. Four perforations out of ten (40 %) occurred through anterior-superior portal with one associated nerve injury. One perforation out of ten (10 %) occurred through lateral transmuscular portal without any nerve injury. The mean depth was calculated as 17.6 mm (SD 3) for anterior-superior portal and 26.5 mm (SD 3.6) for lateral transmuscular portal (P < 0.001). It is anatomically possible that suprascapular nerve could sustain iatrogenic injury during labral anchor placement during SLAP repair. However, lateral transmuscular portal at 12 o'clock drill entry location has lower risk of suprascapular nerve injury compared with anterior-superior portal at 1 o'clock drill entry location.
What Is the Optimal Minimum Penetration Depth for "All-Inside" Meniscal Repairs?
McCulloch, Patrick C; Jones, Hugh L; Lue, Jeffrey; Parekh, Jesal N; Noble, Philip C
2016-08-01
To identify desired minimum depth setting for safe, effective placement of the all-inside meniscal suture anchors. Using 16 cadaveric knees and standard arthroscopic techniques, 3-dimensional surfaces of the meniscocapsular junction and posterior capsule were digitized. Using standard anteromedial and anterolateral portals, the distance from the meniscocapsular junction to the posterior capsule outer wall was measured for 3 locations along the posterior half of medial and lateral menisci. Multiple all-inside meniscal repairs were performed on 7 knees to determine an alternate measure of capsular thickness (X2) and compared with the digitized results. In the digitized group, the distance (X1) from the capsular junction to the posterior capsular wall was averaged in both menisci for 3 regions using anteromedial and anterolateral portals. Mean distances of 6.4 to 8.8 mm were found for the lateral meniscus and 6.5 to 9.1 mm for the medial meniscus. The actual penetration depth was determined in the repair group and labeled X2. It showed a similar pattern to the variation seen in X1 by region, although it exceeded predicted distances an average 1.7 mm in the medial and 1.5 mm in the lateral meniscus owing to visible deformation of the capsule as it pierced. Capsular thickness during arthroscopic repair measures approximately 6 to 9 mm (X1), with 1.5 to 2 mm additional depth needed to ensure penetration rather than bulging of the posterior capsule (X2), resulting in 8 to 10 mm minimum penetration depth range. Surgeons can add desired distance away from the meniscocapsular junction (L) at device implantation, finding optimal minimal setting for penetration depth (X2 + L), which for most repairable tears may be as short as 8 mm and not likely to be greater than 16 mm. Minimum depth setting for optimal placement of all-inside meniscal suture anchors when performing all-inside repair of the medial or lateral meniscus reduces risk of harming adjacent structures secondary to overpenetration and underpenetration of the posterior capsule. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Das, Anupam; Yadav, C S; Gamanagatti, Shivanand; Pandey, R M; Mittal, Ravi
2018-06-13
The outcome of single-bundle anterior cruciate ligament (ACL) reconstruction depends largely on the anatomic placement of bone tunnel. The lateral intercondylar ridge (LIR) and bifurcate ridge (BR) are useful bony landmarks for femoral tunnel placement. The purpose of our study was to compare the bony landmarks of ACL footprint on femur by three-dimensional computed tomography (3D CT) scan and arthroscopy in chronic ACL-deficient knees. Fifty patients above 18 years of age who were diagnosed of having ACL tear were selected for the study. All the cases were more than 6 months old since the injury. Preoperative 3D CT scan of the affected knee was obtained for each of them. They underwent single-bundle anatomic ACL reconstruction. Measurements were done on the preoperative 3D CT and arthroscopy to quantify the position of the LIR and BR. The proximodistal distance of lateral femoral condyle was 21.41+/-2.5 mm on CT scan and 22.02+/-2.02 mm on arthroscopy. On preoperative 3D CT scan, the midpoint of the LIR was found to be located at a mean distance of 11.17±2.11 mm from the proximal margin of the lateral femoral condyle. On arthroscopy, it was at 10.18+/-1.52 mm from the proximal margin the lateral femoral condyle. The "bifurcate ridge"(BR) was not visible in any of the cases during arthroscopy or CT scan. We concluded that LIR is an easily identifiable bony landmark on arthroscopy in all cases. It can also be identified on CT scans. BR is not identified both on arthroscopy and CT scans in chronic ACL tears. The arthroscopic measurements of bony landmarks are quite close to those of CT scan. Midpoint of LIR is at 52.185% of the proximodistal distance on CT scan evaluation and it is at 46.21% on arthroscopic evaluation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Leonard, Charles E; Tallhamer, Michael; Johnson, Tim; Hunter, Kari; Howell, Kathryn; Kercher, Jane; Widener, Jodi; Kaske, Terese; Paul, Devchand; Sedlacek, Scot; Carter, Dennis L
2010-02-01
To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume. Copyright 2010 Elsevier Inc. All rights reserved.
How do deltoid muscle moment arms change after reverse total shoulder arthroplasty?
Walker, David R; Struk, Aimee M; Matsuki, Keisuke; Wright, Thomas W; Banks, Scott A
2016-04-01
Although many advantages of reverse total shoulder arthroplasty (RTSA) have been demonstrated, a variety of complications indicate there is much to learn about how RTSA modifies normal shoulder function. This study used a subject-specific computational model driven by in vivo kinematic data to assess how RTSA affects deltoid muscle moment arms after surgery. A subject-specific 12 degree-of-freedom musculoskeletal model was used to analyze the shoulders of 26 individuals (14 RTSA and 12 normal). The model was modified from the work of Holzbaur to directly input 6 degree-of-freedom humeral and scapular kinematics obtained using fluoroscopy. The moment arms of the anterior, lateral, and posterior aspects of the deltoid were significantly different when RTSA and normal cohorts were compared at different abduction angles. Anterior and lateral deltoid moment arms were significantly larger in the RTSA group at the initial elevation of the arm. The posterior deltoid was significantly larger at maximum elevation. There was large intersubject variability within the RTSA group. Placement of implant components during RTSA can directly affect the geometric relationship between the humerus and scapula and the muscle moment arms in the RTSA shoulder. RTSA shoulders maintain the same anterior and posterior deltoid muscle moment-arm patterns as healthy shoulders but show much greater intersubject variation and larger moment-arm magnitudes. These observations provide a basis for determining optimal implant configuration and surgical placement to maximize RTSA function in a patient-specific manner. Published by Elsevier Inc.
Perelli, Michele; Abundo, Roberto; Corrente, Giuseppe; Saccone, Carlo
2017-01-01
Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant's success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one. PMID:29403665
Perelli, Michele; Abundo, Roberto; Corrente, Giuseppe; Saccone, Carlo; Arduino, Paolo G
2017-01-01
Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant's success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one.
iPod touch-assisted instrumentation of the spine: a technical report.
Jost, Gregory F; Bisson, Erica F; Schmidt, Meic H
2013-12-01
Instrumentation of the spine depends on choosing the correct insertion angles to implant screws. Although modern image guidance facilitates precise instrumentation of the spine, the equipment is costly and availability is limited. Although most surgeons use lateral fluoroscopy to guide instrumentation in the sagittal plane, the lateromedial angulation is often chosen by estimation. To overcome the associated uncertainty, iPod touch-based applications for measuring angles can be used to assist with screw implantation. To evaluate the use of the iPod touch to adjust instruments to the optimal axial insertion angle for placement of pedicle screws in the lumbar spine. Twenty lumbar pedicle screws in 5 consecutive patients were implanted using the iPod touch. The lateromedial angulation was measured on preoperative images and reproduced in the operative field with the iPod touch. The instruments to implant the screws were aligned with the side of the iPod for screw insertion. Actual screw angles were remeasured on postoperative imaging. We collected demographic, clinical, and operative data for each patient. In 16 of 20 screws, the accuracy of implantation was within 3 degrees of the ideal trajectory. The 4 screws with an angle mismatch of 7 to 13 degrees were all implanted at the caudal end of the exposure, where maintaining the planned angulation was impeded by strong muscles pushing medially. iPod touch-assisted instrumentation of the spine is a very simple technique, which, in combination with a lateral fluoroscopy, may guide placement of pedicle screws in the lumbar spine.
Yson, Sharon C; Sembrano, Jonathan N; Santos, Edward R G; Luna, Jeffrey T P; Polly, David W
2014-10-01
Retrospective comparative radiographic review. To determine if lateral to prone repositioning before posterior fixation confers additional operative level lordosis in lateral lumbar interbody fusion (LLIF) procedures. In a review of 56 consecutive patients who underwent LLIF, there was no statistically significant change in segmental lordosis from lateral to prone once a cage is in place. The greatest lordosis increase was observed after cage insertion. We reviewed 56 consecutive patients who underwent LLIF in the lateral position followed by posterior fixation in the prone position. Eighty-eight levels were fused. Disk space angle was measured on intraoperative C-arm images, and change in operative level segmental lordosis brought about by each of the following was determined: (1) cage insertion, (2) prone repositioning, and (3) posterior instrumentation. Paired t test was used to determine significance (α=0.05). Mean lordosis improvement brought about by cage insertion was 2.6 degrees (P=0.00005). There was a 0.1 degree mean lordosis change brought about by lateral to prone positioning (P=0.47). Mean lordosis improvement brought about by posterior fixation, including rod compression, was 1.0 degree (P=0.03). In LLIF procedures, the largest increase in operative level segmental lordosis is brought about by cage insertion. Further lordosis may be gained by placing posterior fixation, including compressive maneuvers. Prone repositioning after cage placement does not produce any incremental lordosis change. Therefore, posterior fixation may be performed in the lateral position without compromising operative level sagittal alignment.
Air bubble migration is a random event post embryo transfer.
Confino, E; Zhang, J; Risquez, F
2007-06-01
Air bubble location following embryo transfer (ET) is the presumable placement spot of embryos. The purpose of this study was to document endometrial air bubble position and migration following embryo transfer. Multicenter prospective case study. Eighty-eight embryo transfers were performed under abdominal ultrasound guidance in two countries by two authors. A single or double air bubble was loaded with the embryos using a soft, coaxial, end opened catheters. The embryos were slowly injected 10-20 mm from the fundus. Air bubble position was recorded immediately, 30 minutes later and when the patient stood up. Bubble marker location analysis revealed a random distribution without visible gravity effect when the patients stood up. The bubble markers demonstrated splitting, moving in all directions and dispersion. Air bubbles move and split frequently post ET with the patient in the horizontal position, suggestive of active uterine contractions. Bubble migration analysis supports a rather random movement of the bubbles and possibly the embryos. Standing up changed somewhat bubble configuration and distribution in the uterine cavity. Gravity related bubble motion was uncommon, suggesting that horizontal rest post ET may not be necessary. This report challenges the common belief that a very accurate ultrasound guided embryo placement is mandatory. The very random bubble movement observed in this two-center study suggests that a large "window" of embryo placement maybe present.
Pneumoperitoneum Caused by Transhepatic Air Leak After Metallic Biliary Stent Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jei Hee; Lee, Deok Hee; Yu, Jeong-Sik
2000-11-15
A self-expanding metallic biliary stent was placed for palliation of a common bile duct obstruction in a 68-year-old male with unresectable pancreatic head cancer 3 days after initial percutaneous right transhepatic catheter decompression. The stent crossed the ampulla of Vater. Three days later, the stent was balloon-dilated and the percutaneous access was removed. At removal, a small contrast leak from the transhepatic tract was seen. Three days later, pneumoperitoneum was found with symptoms of peritoneal irritation and fever. A widely open sphincter of Oddi caused by the metallic stent, accompanied by delayed sealing of the transhepatic tract, may have causedmore » the air and bile leakage into the peritoneal space. This case shows that pneumoperitoneum may occur without ductal tear or bowel injury, with a biliary stent crossing the ampulla of Vater.« less
Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.
Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin
2016-12-01
Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures.
Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.
Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy
2018-03-01
OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI joint dysfunction significantly reduces the ROM of the treated side, but does not significantly reduce the ROM of the nontreated contralateral SI joint. Bilateral stabilization is necessary to significantly reduce the ROM for both SI joints.
Hoffmann, Martin F; Burgers, Travis A; Mason, James J; Williams, Bart O; Sietsema, Debra L; Jones, Clifford B
2014-07-01
In the United States there are more than 230,000 total hip replacements annually, and periprosthetic femoral fractures occur in 0.1-4.5% of those patients. The majority of these fractures occur at the tip of the stem (Vancouver type B1). The purpose of this study was to compare the biomechanically stability and strength of three fixation constructs and identify the most desirable construct. Fifteen medium adult synthetic femurs were implanted with a hip prosthesis and were osteotomized in an oblique plane at the level of the implant tip to simulate a Vancouver type B1 periprosthetic fracture. Fractures were fixed with a non-contact bridging periprosthetic proximal femur plate (Zimmer Inc., Warsaw, IN). Three proximal fixation methods were used: Group 1, bicortical screws; Group 2, unicortical screws and one cerclage cable; and Group 3, three cerclage cables. Distally, all groups had bicortical screws. Biomechanical testing was performed using an axial-torsional testing machine in three different loading modalities (axial compression, lateral bending, and torsional/sagittal bending), next in axial cyclic loading to 10,000 cycles, again in the three loading modalities, and finally to failure in torsional/sagittal bending. Group 1 had significantly greater load to failure and was significantly stiffer in torsional/sagittal bending than Groups 2 and 3. After cyclic loading, Group 2 had significantly greater axial stiffness than Groups 1 and 3. There was no difference between the three groups in lateral bending stiffness. The average energy absorbed during cyclic loading was significantly lower in Group 2 than in Groups 1 and 3. Bicortical screw placement achieved the highest load to failure and the highest torsional/sagittal bending stiffness. Additional unicortical screws improved axial stiffness when using cable fixation. Lateral bending was not influenced by differences in proximal fixation. To treat periprosthetic fractures, bicortical screw placement should be attempted to maximize load to failure and torsional/sagittal bending stiffness. Copyright © 2014 Elsevier Ltd. All rights reserved.
The anterior approach for a non-image-guided intra-articular hip injection.
Mei-Dan, Omer; McConkey, Mark O; Petersen, Brian; McCarty, Eric; Moreira, Brett; Young, David A
2013-06-01
The purpose of this study was to investigate and validate the accuracy and safety of a technique using an anterior approach for non-image-guided intra-articular injection of the hip by use of anatomic landmarks. We enrolled 55 patients. Injections were performed before supine hip arthroscopy after landmarking and before application of traction. After the needle insertion, success was confirmed with an air arthrogram and by direct visualization after arthroscope insertion. Accuracy and difficulty achieving correct needle placement were correlated with age, weight, height, body mass index, body type, gender, and surgical indication, as well as femoral and pelvic morphology. Forty-five patients who underwent injection in the office were followed up separately to document injection side effects. Needle placement accuracy was correlated to patients' demographics. All statistical tests with P values were 2 sided, with the level of significance set at P < .05. There were 51 correct needle placements and 4 misses, yielding a 93% success rate. The most common location for needle placement was the upper medial head-neck junction. Female gender was correlated with a more difficult needle placement and misses in relation to group size (P = .06). The reasons for misplacements of the needle were a high-riding trochanter, increased femoral version, thick adipose tissue over the landmarks, and variant of ilium morphology. Of 45 patients in the side effect study arm, 3 reported sensory changes of the lateral femoral cutaneous nerve that resolved within 24 hours. Hip injections by use of the direct anterior approach, from the intersection of the lines drawn from the anterior superior iliac spine and 1 cm distal to the tip of the greater trochanter, are safe and reproducible. Patient characteristics, such as increased subcutaneous adipose tissue or osseous anatomic variants, can lead to difficulty in placing the needle successfully. These characteristics can be predicted with the aid of physical examination and careful study of the pelvic radiographs. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Roberts, Chris; Shadbolt, Narelle; Clark, Tyler; Simpson, Phillip
2014-09-20
Little is known about the technical adequacy of portfolios in reporting multiple complex academic and performance-based assessments. We explored, first, the influencing factors on the precision of scoring within a programmatic assessment of student learning outcomes within an integrated clinical placement. Second, the degree to which validity evidence supported interpretation of student scores. Within generalisability theory, we estimated the contribution that each wanted factor (i.e. student capability) and unwanted factors (e.g. the impact of assessors) made to the variation in portfolio task scores. Relative and absolute standard errors of measurement provided a confidence interval around a pre-determined pass/fail standard for all six tasks. Validity evidence was sought through demonstrating the internal consistency of the portfolio and exploring the relationship of student scores with clinical experience. The mean portfolio mark for 257 students, across 372 raters, based on six tasks, was 75.56 (SD, 6.68). For a single student on one assessment task, 11% of the variance in scores was due to true differences in student capability. The most significant interaction was context specificity (49%), the tendency for one student to engage with one task and not engage with another task. Rater subjectivity was 29%. An absolute standard error of measurement of 4.74%, gave a 95% CI of +/- 9.30%, and a 68% CI of +/- 4.74% around a pass/fail score of 57%. Construct validity was supported by demonstration of an assessment framework, the internal consistency of the portfolio tasks, and higher scores for students who did the clinical placement later in the academic year. A portfolio designed as a programmatic assessment of an integrated clinical placement has sufficient evidence of validity to support a specific interpretation of student scores around passing a clinical placement. It has modest precision in assessing students' achievement of a competency standard. There were identifiable areas for reducing measurement error and providing more certainty around decision-making. Reducing the measurement error would require engaging with the student body on the value of the tasks, more focussed academic and clinical supervisor training, and revisiting the rubric of the assessment in the light of feedback.
Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Shirakawa, Nobuyuki; Tanaka, Sakae
2016-07-01
Tilting of the mobile bearing relative to the tibial tray in the flexion position may result from the implantation of femoral components more laterally relative to tibial components during unicompartmental knee arthroplasty (UKA) using the Oxford Knee. The purpose of the present study was to compare femoral component positions after UKA using the phase 3 device and a novel device. We further evaluated the placement of the femoral components with the new device in the flexion position to determine the association with short-term prognosis. The location of femoral and tibial components in the flexion position of 38 knees implanted using the phase 3 device and 49 knees using a novel device was assessed at 1 year postoperatively using radiography of the proximal tibia and distal femur in the flexion position. The femoral component was implanted more laterally using the new device than using the phase 3 device in the flexion position (P = .012), which caused the impingement of the mobile bearing against the lateral wall of the tibial tray. After UKA using the new device, 10% of patients exhibited the tilting phenomenon of the mobile bearing because of the lateral implantation of the femoral implant. To prevent implantation of the femoral component too laterally using the new device during UKA, knee surgeons should set the drill guide more medially such that the center of the drill is aligned with the middle of the medial femoral condyle. Copyright © 2016 Elsevier Inc. All rights reserved.
Gordon-Evans, Wanda J; Dunning, Diane; Johnson, Ann L; Knap, Kim E
2011-07-01
To determine whether carprofen, a commercially available NSAID, would decrease perceived exertion and signs of pain in dogs and therefore increase muscle mass and hind limb function without decreasing range of motion after lateral fabellar suture stabilization. Randomized, blinded, controlled clinical trial. 35 dogs with cranial cruciate ligament rupture and lateral fabellar suture stabilization followed by rehabilitation. All dogs underwent surgical stabilization of cranial cruciate ligament rupture by placement of a lateral fabellar suture. Dogs received carprofen (2.2 mg/kg [1 mg/lb], PO, q 12 h) for the first 7 days after surgery and underwent concentrated rehabilitation exercises during weeks 3, 5, and 7 after surgery. Eighteen dogs also received carprofen (2.2 mg/kg, PO, q 12 h) during the weeks of concentrated rehabilitation. Outcomes were measured by a single investigator, who was blinded to group assignments, using pressure platform gait analysis, goniometry, thigh circumference, and mean workout speed at a consistent level of exertion. There were no differences between the 2 groups in ground reaction forces, thigh circumference, or exertion (mean workout speed) over time or at any individual time point. However, both groups improved significantly over time for all outcome measures. Providing carprofen to dogs during concentrated rehabilitation after lateral fabellar suture stabilization did not improve hind limb function, range of motion, or thigh circumference, nor did it decrease perceived exertion, compared with control dogs. Carprofen was not a compulsory component of a physical therapy regimen after lateral fabellar suture stabilization.
Schneider Membrane Elevation in Presence of Sinus Septa: Anatomic Features and Surgical Management
Beretta, Mario; Cicciù, Marco; Bramanti, Ennio; Maiorana, Carlo
2012-01-01
Maxillary sinus floor elevation via a lateral approach is a predictable technique to increase bone volume of the edentulous posterior maxilla and consequently for dental implants placement. The sinus floor is elevated and it can be augmented with either autologous or xenogeneic bone grafts following an opening bone window created on the facial buccal wall. Maxillary septa are walls of cortical bone within the maxillary sinus. The septa shape has been described as an inverted gothic arch arising from the inferior or lateral walls of the sinus and may even divide the sinus into two or more cavities. Some authors have reported a higher prevalence of septa in atrophic edentulous areas than in nonatrophic ones. Radiographic identification of these structures is important in order to perform the right design of the lateral window during sinus lift. Aim of this investigation is to highlight the correct steps for doing sinus lift surgery in presence of those anatomic variations. Clinicians should always perform clinical and radiographic diagnosis in order to avoid complications related to the sinus lift surgery. PMID:22848223
An anatomical study of arcuate foramen and its clinical implications: a case report.
Afsharpour, Salman; Hoiriis, Kathryn T; Fox, R Bruce; Demons, Samuel
2016-01-01
The objective of this paper is to describe the relationship of the vertebral artery (VA) to the Atlas (C1) in the sub-occipital region in the presence of arcuate foramen; and discuss the clinical implications related to manual therapies and surgical implications related to screw placement. This study is an anatomical cadaveric case report of symmetrical bilateral lateral and dorsal arcuate foramina on the C1 dorsal arch. Out of 40 cadavers that were available for use in teaching anatomy in the university setting, three presented with anomalies of the C1 dorsal arch. The sub-occipital regions were skillfully prosected to preserve related structures, especially VAs, sub-occipital and greater occipital nerves. Visual observations, photographs, measurements, and radiographic examinations were performed between January 15, 2014 and August 25, 2014. One cadaver (Specimen A) presented with complete bilateral ossified arcuate foramina, and two presented with partial ossification of the atlanto-occipital membrane. Specimen A presented the bilateral anomaly which is almost symmetrical. The VAs were found passing through double foramina (lateral and dorsal) on each side. Arcuate foramina have been shown to be commonly found anomalies with highly variable shapes and sizes, even in the same individual with a bilateral condition. This study found a rare type of the anomaly associated with the C1 dorsal arch, which protected the VA against manual pressure. However, VA, in this case, would be more susceptible to dissection. The presence of the arcuate foramen would also complicate screw placement during surgery. Clinical pre-screening for signs of vertebrobasilar insufficiency is important for chiropractic and manual therapies.
Pader, Karine; Burns, Patrick M; Brisville, Anne-Claire; Rousseau, Marjolaine; Blond, Laurent; Truchetti, Geoffrey; Lardé, Hélène; Lapointe, Catherine; Francoz, David
2017-05-01
CASE DESCRIPTION A 4-hour-old 6.3-kg (13.9-lb) female alpaca cria was evaluated because of severe respiratory distress and difficulty nursing since birth. CLINICAL FINDINGS The cria had open-mouth breathing and cyanotic membranes, with no airflow evident from either nostril. Supplemental oxygen was delivered, and the patient was anesthetized and intubated orotracheally; a CT evaluation of the head confirmed bilateral membranous obstruction of the nasal cavities, consistent with complete bilateral choanal atresia. TREATMENT AND OUTCOME Choanal atresia was treated with an endoscopically assisted balloon-dilation technique, and temporary tracheostomy was performed. Stenosis recurred, requiring revision of the repair and intranasal stent placement 3 days after the first surgery. The tracheostomy tube was removed the next day. Complications during hospitalization included mucoid obstruction of the tracheostomy tube, granulation tissue development in the trachea near the tracheostomy site, mucoid stent obstruction, aspiration pneumonia, and presumed partial failure of passive transfer of immunity. The stents were removed 2 weeks after admission, and the cria was discharged 3 days later. The owner was advised that the animal should not be bred. At last follow-up 3 years later, the alpaca was doing well. CLINICAL RELEVANCE Surgical treatment with a balloon-dilation technique and placement of nasal stents with endoscopic guidance were curative in this neonatal alpaca with bilateral membranous choanal atresia. Computed tomography was useful to determine the nature of the atresia and aid surgical planning. Because a genetic component is likely, owners should be advised to prevent affected animals from breeding.
Dursun, Erhan; Keceli, Huseyin Gencay; Uysal, Serdar; Güngör, Hamiyet; Muhtarogullari, Mehmet; Tözüm, Tolga Fikret
2016-05-01
Inferior alveolar nerve lateralization (IANL) and short dental implants (SDI) are 2 viable implant-based treatment approaches in the presence of atrophied posterior mandible. Despite the risks of dysfunction, infection, and pathologic fractures in IANL, it becomes possible to place standard implants. The purpose of this study was to compare SDI and IANL approaches from clinical and radiographic aspects. Fifteen subjects having unilateral atrophic mandibles were allocated to SDI and IANL treatment groups. Following surgical procedures, early postoperative complications, implant survival, and periimplant clinical and radiographic parameters including probing pocket depth, attachment level, keratinized tissue amount, vertical tissue recession, and marginal bone loss were recorded at baseline and 1-year after prosthetic rehabilitation. In both groups, no implant was lost. Except usual postoperative complications, 2 patients had transient paraesthesia after IANL. According to time-dependent evaluation, both groups showed significant increase in probing pocket depth and attachment level at 1-year follow-up compared with baseline (P < 0.05). Except a slight but significant increase in mesial surface of SDI group (P < 0.05), no remarkable time-dependent change was identified in vertical tissue recession. Keratinized tissue amount did not exhibit any inter- or intragroup difference during whole study period. Marginal bone loss did not show any difference between IANL and SDI groups at follow-up. SDI placement or standard length implant placement with IANL can be considered promising alternatives in the treatment of atrophic mandibular posterior regions. However, SDI may be preferred in terms of lower complication risk.
Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-06-01
Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.
Chronic pancreatitis with multiple pseudocysts and pancreatic panniculitis: A case report.
Gu, Yuqing; Qian, Zhuyin
2018-06-01
Pancreatic pseudocyst can present single or multiple, inside or outside the pancreas. Pancreatic panniculitis is a rare skin lesion in pancreatic disease patients. The purpose of this study is to report a case of chronic pancreatitis coexisting with multiple pseudocysts and pancreatic panniculitis. A 46-year-old man with chronic pancreatitis presented multiple small cystic lesions inside the head of the pancreas and two large cystic lesions adjacent to the tail of the pancreas. The patient also developed subcutaneous nodules involving upper and lower limbs, hands, and lower abdomen bilaterally. The patient was diagnosed with pancreatic pseudocyst and pancreatic panniculitis resulted from chronic pancreatitis. Bile duct stent and pancreatic duct stent placement was performed endoscopicly. Panniculitis faded three weeks later and the pancreatic pseudocysts disappeared six weeks later. Clinicians should be aware of the manifestation of multiple pancreatic pseudocyst and pancreatic panniculitis, and endoscopic transpapillary drainage may be a effective way in this scenario.
Streptomycin ototoxicity and hair cell regeneration in the adult pigeon utricle
NASA Technical Reports Server (NTRS)
Frank, T. C.; Dye, B. J.; Newlands, S. D.; Dickman, J. D.
1999-01-01
OBJECTIVE: The purpose of this study was to develop a technique to investigate the regeneration of utricular hair cells in the adult pigeon (Columba livia) following complete hair cell loss through administration of streptomycin. STUDY DESIGN: Experimental animal study. METHODS: Animals were divided into four groups. Group 1 received 10 to 15 days of systemic streptomycin injections. Animals in Groups 2 and 3 received a single direct placement of a 1-, 2-, 4-, or 8-mg streptomycin dose into the perilymphatic space. Animals in Groups 1 and 2 were analyzed within 1 week from injection to investigate hair cell destruction, whereas Group 3 was investigated at later dates to study hair cell recovery. Group 4 animals received a control injection of saline into the perilymphatic space. Damage and recovery were quantified by counting hair cells in isolated utricles using scanning electron microscopy. RESULTS: Although systemic injections failed to reliably achieve complete utricular hair cell destruction, a single direct placement of a 2-, 4-, or 8-mg streptomycin dose caused complete destruction within the first week. Incomplete hair cell loss was observed with the 1-mg dose. Over the long term, regeneration of the hair cells was seen with the 2-mg dose but not the 8-mg dose. Control injections of saline into the perilymphatic space caused no measurable hair cell loss. CONCLUSIONS: Direct placement of streptomycin into the perilymph is an effective, reliable method for complete destruction of utricular hair cells while preserving the regenerative potential of the neuroepithelium.
Influences on final year medical students' attitudes to general practice as a career.
Parker, Johanna E; Hudson, Ben; Wilkinson, Tim J
2014-03-01
General practice is under-represented in student career choices. This study aimed to identify and explore factors that influence the attitudes of final year medical students to general practice as a career. This qualitative study used semi-structured interviews of focus groups of final year undergraduate medical students at the University of Otago, Christchurch, New Zealand. Thematic analysis and grounded theory were used to interpret the data. General practitioners (GPs) play a key role in influencing medical students' attitudes to general practice as a career. Students identified their general practice placement during medical school training and personal contact with their own GP as principal factors. The media portrayal of general practice and the attitudes of friends and family were also influential. Students were positively influenced when they were made to feel part of the team, involved with consultations, allowed to carry out practical procedures under supervision, and witnessed what they perceived as good medical practice during clinical placements. Positive experiences often occurred later in training, when students felt more confident of their clinical abilities. While students reported occasional negative comments about general practice by some hospital doctors, these had a lesser role in influencing their perceptions of general practice compared with their own experiences, both as students and patients. GPs have a strong influence, positively and negatively, on the attitudes of medical students to general practice as a career. Effective influences include being made to feel welcome, involved, valued, and given legitimate roles during clinical placements.
Allograft for maxillary sinus floor augmentation: a retrospective study of 90 cases.
Guerrero, Jaime S; Al-Jandan, Badr A
2012-04-01
The aim of this study is to demonstrate the clinical applicability and efficacy of an allograft for maxillary sinus augmentations in patients requiring placement of dental implants. Sixty consecutive patients underwent a total of 90 sinus augmentations. Twenty-nine were women and 31 men, with a mean age of 54 years. Twenty-six patients received a bilateral procedure and 34 unilateral. All cases were treated with the lateral wall technique. Allograft consisted of demineralized freeze-dried blocks in 6 cases, particulate in 82 cases, and a combination of both in 2 cases. In 30 patients, it was combined with platelet-rich plasma. A total of 84 implants were inserted. Bone samples of grafted areas were obtained in two patients for histological examination. Seventy-three implants were clinically successful at the reentry time. Eleven implants in seven patients were removed between 15 days and 6 months after their placement. Seven of these implants were replaced and received prostheses as well, for an overall postloading success rate of 95.2%. Follow-up for all patients after final restoration was between 12 and 96 months. Specimen's histological evaluation revealed bone formation and evidence of inflammatory infiltrate. Based on the findings of this study, it can be suggested that the use of the demineralized freeze-dried bone allograft from the Banco de Huesos y Tejidos Fundación Cosme y Damian for sinus augmentation is effective and constitutes a feasible therapeutic alternative for implant placement.
Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.
Sasso, Rick C; Best, Natalie M; Potts, Eric A
2005-01-01
Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.
Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?
Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M
2009-01-01
Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.
Greenbaum, Alissa; Parasher, Gulshan; Demarest, Gerald; Auyang, Edward
2017-05-05
Iatrogenic duodenal injury occurring during laparoscopic cholecystectomy (LC) is managed surgically, though rarely a large, persistent fistula is refractory to surgical interventions. We present the case of a 40-year-old woman transferred to our centre following elective LC for a reported perforated duodenal ulcer. An uncontained leak was found to originate from a 1.5 cm duodenal defect, with no evidence of ulceration. A duodenostomy tube was placed. One month after abdominal closure, the patient continued to have a persistent, large duodenal fistula. A through-the-scope covered oesophageal stent was placed under endoscopic and fluoroscopic guidance. Five weeks later, it was successfully retrieved and no subsequent extravasation of contrast from the duodenum was noted. Unrecognised iatrogenic duodenal injuries sustained during LC can be catastrophic. In cases of massive duodenal defects and high-output biliary fistula uncontrolled after surgical intervention, endoscopic-guided and fluoroscopic-guided placement of a fully covered oesophageal stent may be lifesaving. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Subselenean tunneler melting head design: A preliminary study
NASA Technical Reports Server (NTRS)
Engblom, Bill; Graham, Eric; Perera, Jeevan; Strahan, Alan; Ro, Ted
1988-01-01
The placement of base facilities in subsurface tunnels created as a result of subsurface mining is described as an alternative to the establishing of a base on the lunar surface. Placement of the base facilities and operations in subselenean tunnels will allow personnel to live and work free from the problem of radiation and temperature variations. A conceptual design for a tunneling device applicable to such a lunar base application was performed to assess the feasibility of the concept. A tunneler was designed which would melt through the lunar material leaving behind glass lined tunnels for later development. The tunneler uses a nuclear generator which supplies the energy to thermally melt the regolith about the cone shaped head. Melted regolith is exacavated through intakes in the head and transferred to a truck which hauls it to the surface. The tunnel walls are solidified to provide support lining by using an active cooling system about the mid section of the tunneler. Also addressed is the rationale for a subselenean tunneler and the tunneler configuration and subsystems, as well as the reasoning behind the resulting design.
Palacios, Jesús; Román, Maite; Camacho, Carlos
2011-03-01
Following initial adversity, internationally adopted children arrive with significant growth and developmental delays. Post-placement recovery has been widely documented, but little has been known about its extent and timing several years after placement and in children with diverse pre-adoptive experiences. A total of 289 children adopted from six countries into Spanish families were studied. Growth and psychological development were considered on arrival and after an average of over 3 years. Growth and developmental initial delays affected a substantial percentage of the children. Post-adoption recovery seemed quicker and more complete in weight and height than in head circumference and psychological development. Initial and later values were correlated, but growth-development relation on arrival subsequently lost significance. Most of the catch-up happened in the first three post-adoption years. Adoption offers an impressive opportunity for recovery after previous adversity, although continuity between past and present persists. The improvement is more marked in some areas than in others and more substantial in the first post-adoption years. © 2010 Blackwell Publishing Ltd.
Meakings, Sarah; Selwyn, Julie
2016-10-01
Foster care remains a valuable and safe intervention for many children unable to live with their birth family. When birth family reunification is not considered possible, a small proportion of children in foster care will go on to achieve permanency by way of adoption. This article reports on some unexpected findings to emerge from two national adoption studies of previously looked after children in England and Wales. Focussing on a subset of families who had experienced or were at risk of an adoption disruption, the findings revealed that not only did children carry elevated risks for disruption due to their older age at entry to care, multiple foster care placements and traumatic early histories, but once in care, many of the children whose placements had disrupted were considered by their adoptive parents to have had very poor, even harmful fostering experiences before being placed for adoption. Possible explanations for these findings are discussed, together with the implications for social work practice. © The Author(s) 2016.
Tanisaka, Yuki; Ryozawa, Shomei; Kobayashi, Masanori; Harada, Maiko; Kobatake, Tsutomu; Omiya, Kumiko; Iwano, Hirotoshi; Arai, Shin; Nonaka, Kouichi; Mashimo, Yumi
2018-02-01
Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117-205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5-24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed.
Sakurai, Katsunobu; Amano, Ryosuke; Yamamoto, Akira; Nishida, Norifumi; Matsutani, Shinya; Hirata, Keiichiro; Kimura, Kenjiro; Muguruma, Kazuya; Toyokawa, Takahiro; Kubo, Naoshi; Tanaka, Hiroaki; Yashiro, Masakazu; Ohira, Masaichi; Hirakawa, Kosei
2014-01-01
This report describes the successful use of portal venous stent placement for a patient with recurrent melena secondary to jejunal varices that developed after subtotal stomach preserved pancreatoduodenectomy (SSPPD). A 67-year-old man was admitted to our hospital with tarry stool and severe anemia at 2 years after SSPPD for carcinoma of the head of the pancreas. Abdominal computed tomography examination showed severe stenosis of the extrahepatic portal vein caused by local recurrence and showed an intensely enhanced jejunal wall at the choledochojejunostomy. Gastrointestinal bleeding scintigraphy also revealed active bleeding near the choledochojejunostomy. Based on these findings, jejunal varices resulting from portal vein stenosis were suspected as the cause of the melena. Portal vein stenting and balloon dilation was performed via the ileocecal vein after laparotomy. Coiling of the jejunal varices and sclerotherapy of the dilate postgastric vein with 5% ethanolamine oleate with iopamidol was performed. After portal stent placement, the patient was able to lead a normal life without gastrointestinal hemorrhage. However, he died 7 months later due to liver metastasis. PMID:24444277
Löser, C
2000-09-01
A case of decisive material degeneration of an esophageal Celestin tube is described: a 50-year-old man with adenocarcinoma of the distal esophagus received a Celestin tube for palliative endoscopic treatment and 8 months later presented with suddenly occurring complete dysphagia. Dissolution of the latex layer in the proximal as well as the distal part of the tube had caused self-disintegration of the Celestin tube and had liberated the monofilament nylon coil which completely obstructed the lumen of the tube. Endoscopic tube removal was only possible by careful attachment of a balloon catheter and peroral extraction after insufflation with contrast medium up to 5 atm. A Medline-based review of the literature revealed different but predominantly severe complications (perforation, hemorrhage, obstruction, and peritonitis) based on material fatigue of the latex layer in esophageal Celestin tubes. At least 6 months after placement of a Celestin tube, regular fluoroscopic controls should be performed to detect early disintegration of the tube. Indication for the placement of Celestin tubes in patients with benign esophageal strictures and longer life expectancy should be assessed very critically.
Mornieux, Guillaume; Gehring, Dominic; Fürst, Patrick; Gollhofer, Albert
2014-01-01
Anticipatory postural adjustments (APAs), i.e. preparatory positioning of the head, the trunk and the foot, are essential to initiate cutting manoeuvres during football games. The aim of the present study was to determine how APA strategies during cutting manoeuvres are influenced by a reduction of the time available to prepare the movement. Thirteen football players performed different cutting tasks, with directions of cutting either known prior to the task or indicated by a light signal occurring 850, 600 or 500 ms before ground contact. With less time available to prepare the cutting manoeuvre, the head was less orientated towards the cutting direction (P = 0.033) and the trunk was even more rotated in the opposite direction (P = 0.002), while the foot placement was not significantly influenced. Moreover, the induced higher lateral trunk flexion correlated with the increased knee abduction moment (r = 0.41; P = 0.009). Increasing lateral trunk flexion is the main strategy used to successfully perform a cutting manoeuvre when less time is available to prepare the movement. However, higher lateral trunk flexion was associated with an increased knee abduction moment and therefore an increased knee injury risk. Reducing lateral trunk flexion during cutting manoeuvres should be part of training programs seeking the optimisation of APAs.
Nakamura, R; Komatsu, N; Fujita, K; Kuroda, K; Takahashi, M; Omi, R; Katsuki, Y; Tsuchiya, H
2017-10-01
Open wedge high tibial osteotomy (OWHTO) for medial-compartment osteoarthritis of the knee can be complicated by intra-operative lateral hinge fracture (LHF). We aimed to establish the relationship between hinge position and fracture types, and suggest an appropriate hinge position to reduce the risk of this complication. Consecutive patients undergoing OWHTO were evaluated on coronal multiplanar reconstruction CT images. Hinge positions were divided into five zones in our new classification, by their relationship to the proximal tibiofibular joint (PTFJ). Fractures were classified into types I, II, and III according to the Takeuchi classification. Among 111 patients undergoing OWHTOs, 22 sustained lateral hinge fractures. Of the 89 patients without fractures, 70 had hinges in the zone within the PTFJ and lateral to the medial margin of the PTFJ (zone WL), just above the PTFJ. Among the five zones, the relative risk of unstable fracture was significantly lower in zone WL (relative risk 0.24, confidence interval 0.17 to 0.34). Zone WL appears to offer the safest position for the placement of the osteotomy hinge when trying to avoid a fracture at the osteotomy site. Cite this article: Bone Joint J 2017;99B10:1313-18. ©2017 The British Editorial Society of Bone & Joint Surgery.
Placement of Public Art. Two Examples from Lisbon’s Waterfront
NASA Astrophysics Data System (ADS)
Ochoa, Rita
2017-10-01
In our contemporary cities, some public spaces seem to have greater ability to host art interventions, like historical centers, urban sprawl areas, gardens and parks, new residential districts, among others. Also in port cities, its waterfronts constitute privileged spaces for the placement of public art. On Lisbon’s riverfront, we can see a relevant number of works and of monuments of strong symbolic nature. In turn, the placement of public art is a way to value the inherently symbolic nature of the waterfronts and to emphasize its monumentality. However, the criteria for the placement of public art on those spaces are not always clear. In some cases, there are some thematic correspondences between the works and the places, namely with the theme of the water, the Discoveries and others like that. Nevertheless, we cannot observe a profound spatial integration, or a design with the context. In some cases, the artistic elements are produced with a logic of isolated work of art and later they are acquired and placed in some public space. In other cases, we assist to an unusual situation: a work is conceived in a strict relation with a place, but then, without any evident justification, it is dislocated to a completely different context. Or simply it is removed, disappearing from the public space. Although it seems a strange situation, such kind of dislocations often occurs in Lisbon. On this framework, this research proposes a discussion about the processes of implementation of public art. We will analyze two cases of public art replacement:1) The monument Primeira Travessia Aérea do Atlântico Sul (First Aerial Crossing of the South Atlantic), by Laranjeira Santos and Rodrigues Fernandes, 1972; and 2) The public sculpture Ribeira das Naus, by Charters de Almeida, 1995. Both works were designed to very specific and important places on Lisbon’s waterfront and both were later replaced to other locations on the inner city, quite far from the river. This kind of “(de)monumentalization” of a space originates the following questions: why is a work removed from a public space and why it is decided to give it another destination? What are the implications of those changes? Is public art removable? Considering public art besides its purely aesthetic significance, this phenomenon seems to reveal that the physical and the social integration with the place are not always important, or, at least, they are only important in some moments. Also, we can see it from another point of view: a removal or a replacement of a work always reveals specific strategies for certain places, in certain moments. We can thus conclude that the processes of implementation of public art are clearly indicators of the policies and of the dynamics of the cities.
Weber, Brittany C; Whitlock, Scott M; He, Kaidi; Kimbrell, Blake S; Derkay, Craig S
2018-04-12
To evaluate the prevalence of middle ear disease in infants referred for failed newborn hearing screening (NBHS) and to review patient outcomes after intervention in order to propose an evidence-based protocol for management of newborns with otitis media with effusion (OME) who fail NBHS. 85 infants with suspected middle ear pathology were retrospectively reviewed after referral for failed NBHS. All subjects underwent a diagnostic microscopic exam with myringotomy with or without placement of a ventilation tube in the presence of a middle ear effusion and had intra-operative auditory brainstem response (ABR) testing or testing at a later date. At the initial office visit, a normal middle ear space bilaterally was documented in 5 babies (6%), 29/85 (34%) had an equivocal exam while 51/85 (60%) had at least a unilateral OME. Myringotomy with or without tube placement due to presence of an effusion was performed on 65/85 (76%) neonates. Normal hearing was established in 17/85 (20%) after intervention, avoiding the need for any further audiologic workup. Bilateral or unilateral sensorineural hearing loss (SNHL) or mixed hearing loss was noted in 54/85 (64%) and these children were referred for amplification. Initially observation with follow up outpatient visits was initiated in 27/85 (32%) however, only 3/27 (11%) resolved with watchful waiting and 24/27 (89%) ultimately required at least unilateral tube placement due to OME and 14/24 (59%) were found to have at least a unilateral mixed or SNHL. An effective initial management plan for children with suspected middle ear pathology and failed NBHS is diagnostic operative microscopy with placement of a ventilation tube in the presence of a MEE along with either intra-operative ABR or close follow-up ABR. This allows for the identification and treatment of babies with a conductive component due to OME, accurate diagnosing of an underlying SNHL component and for prompt aural rehabilitation. Copyright © 2018 Elsevier Inc. All rights reserved.
Avivi-Arber, Limor; Lee, Jye-Chang; Sood, Mandeep; Lakschevitz, Flavia; Fung, Michelle; Barashi-Gozal, Maayan; Glogauer, Michael; Sessle, Barry J
2015-11-01
Tooth loss is common, and exploring the neuroplastic capacity of the face primary motor cortex (face-M1) and adjacent primary somatosensory cortex (face-S1) is crucial for understanding how subjects adapt to tooth loss and their prosthetic replacement. The aim was to test if functional reorganization of jaw and tongue motor representations in the rat face-M1 and face-S1 occurs following tooth extraction, and if subsequent dental implant placement can reverse this neuroplasticity. Rats (n = 22) had the right maxillary molar teeth extracted under local and general anesthesia. One month later, seven rats had dental implant placement into healed extraction sites. Naive rats (n = 8) received no surgical treatment. Intracortical microstimulation (ICMS) and recording of evoked jaw and tongue electromyographic responses were used to define jaw and tongue motor representations at 1 month (n = 8) or 2 months (n = 7) postextraction, 1 month postimplant placement, and at 1-2 months in naive rats. There were no significant differences across study groups in the onset latencies of the ICMS-evoked responses (P > 0.05), but in comparison with naive rats, tooth extraction caused a significant (P < 0.05) and sustained (1-2 months) decreased number of ICMS-defined jaw and tongue sites within face-M1 and -S1, and increased thresholds of ICMS-evoked responses in these sites. Furthermore, dental implant placement reversed the extraction-induced changes in face-S1, and in face-M1 the number of jaw sites even increased as compared to naive rats. These novel findings suggest that face-M1 and adjacent face-S1 may play a role in adaptive mechanisms related to tooth loss and their replacement with dental implants. © 2015 Wiley Periodicals, Inc.
Proficiency-based cervical cancer brachytherapy training.
Zhao, Sherry; Francis, Louise; Todor, Dorin; Fields, Emma C
2018-04-25
Although brachytherapy increases the local control rate for cervical cancer, there has been a progressive decline in its use. Furthermore, the training among residency programs for gynecologic brachytherapy varies considerably, with some residents receiving little to no training. This trend is especially concerning given the association between poor applicator placement and decline in local control. Considering the success of proficiency-based training in other procedural specialties, we developed and implemented a proficiency-based cervical brachytherapy training curriculum for our residents. Each resident placed tandem and ovoid applicators with attending guidance and again alone 2 weeks later using a pelvic model that was modified to allow for cervical brachytherapy. Plain films were taken of the pelvic model, and applicator placement quality was evaluated. Other evaluated metrics included retention of key procedural details, the time taken for each procedure and presession and postsession surveys to assess confidence. During the initial session, residents on average met 4.5 of 5 placement criteria, which improved to 5 the second session. On average, residents were able to remember 7.6 of the 8 key procedural steps. Execution time decreased by an average of 10.5%. Resident confidence with the procedure improved dramatically, from 2.6 to 4.6 of 5. Residents who had previously never performed a tandem and ovoid procedure showed greater improvements in these criteria than those who had. All residents strongly agreed that the training was helpful and wanted to participate again the following year. Residents participating in this simulation training had measurable improvements in the time to perform the procedure, applicator placement quality, and confidence. This curriculum is easy to implement and is of great value for training residents, and would be particularly beneficial in programs with low volume of cervical brachytherapy cases. Simulation programs could also be created for other technically challenging radiation oncology procedures. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Howell, Bryan; Lad, Shivanand P.; Grill, Warren M.
2014-01-01
Spinal cord stimulation (SCS) is an alternative or adjunct therapy to treat chronic pain, a prevalent and clinically challenging condition. Although SCS has substantial clinical success, the therapy is still prone to failures, including lead breakage, lead migration, and poor pain relief. The goal of this study was to develop a computational model of SCS and use the model to compare activation of neural elements during intradural and extradural electrode placement. We constructed five patient-specific models of SCS. Stimulation thresholds predicted by the model were compared to stimulation thresholds measured intraoperatively, and we used these models to quantify the efficiency and selectivity of intradural and extradural SCS. Intradural placement dramatically increased stimulation efficiency and reduced the power required to stimulate the dorsal columns by more than 90%. Intradural placement also increased selectivity, allowing activation of a greater proportion of dorsal column fibers before spread of activation to dorsal root fibers, as well as more selective activation of individual dermatomes at different lateral deviations from the midline. Further, the results suggest that current electrode designs used for extradural SCS are not optimal for intradural SCS, and a novel azimuthal tripolar design increased stimulation selectivity, even beyond that achieved with an intradural paddle array. Increased stimulation efficiency is expected to increase the battery life of implantable pulse generators, increase the recharge interval of rechargeable implantable pulse generators, and potentially reduce stimulator volume. The greater selectivity of intradural stimulation may improve the success rate of SCS by mitigating the sensitivity of pain relief to malpositioning of the electrode. The outcome of this effort is a better quantitative understanding of how intradural electrode placement can potentially increase the selectivity and efficiency of SCS, which, in turn, provides predictions that can be tested in future clinical studies assessing the potential therapeutic benefits of intradural SCS. PMID:25536035
Epidural steroids for treating "failed back surgery syndrome": is fluoroscopy really necessary?
Fredman, B; Nun, M B; Zohar, E; Iraqi, G; Shapiro, M; Gepstein, R; Jedeikin, R
1999-02-01
Epidural steroids are commonly administered in the treatment of "failed back surgery syndrome." Because patient response is dependent on accurate steroid placement, fluoroscopic guidance has been advocated. However, because of ever-increasing medical expenditures, the cost-benefit of routine fluoroscopy should be critically evaluated. Therefore, 50 patients were enrolled into this institutional review board-approved, prospective, controlled, single-blinded study. At a predetermined intervertebral level, the epidural space was identified using an air loss of resistance technique. Thereafter, an epidural catheter was inserted 2 cm through the epidural needle. To determine the accuracy of the clinical placement, contrast medium was administered through the epidural catheter; antero-posterior and lateral lumbar spine radiographs were then obtained. The number of attempts required to successfully locate the epidural space, the reliability of the air loss of resistance technique in indicating successful epidural penetration in failed back surgery syndrome, the ability of the clinician to accurately predict the intervertebral space at which the epidural injection was performed, and the spread of contrast medium within the epidural space were recorded. A total of 48 epidurograms were performed. The number of attempts to successfully enter the epidural space was 2 +/- 1. In 44 cases, the radiological studies confirmed the clinical impression that the epidural space had been successfully identified. In three patients, the epidural catheter was in the paravertebral tissue. One myelogram was recorded. In 25 patients, the epidural catheter did not pass through the predetermined intervertebral space. In 35 cases, the contrast medium did not reach the level of pathology. The clinical sign of loss of resistance is a reliable indicator of epidural space penetration in most cases of "failed back surgery syndrome." However, surface anatomy is unreliable and may result in inaccurate steroid placement. Finally, despite accurate placement, the depot-steroid solution will spread to reach the level of pathology in only 26% of cases.
Westermann, Robert W; DeBerardino, Thomas; Amendola, Annunziato
2014-01-01
Introduction The High Tibial Osteotomy (HTO) is a reliable procedure in addressing uni- compartmental arthritis with associated coronal deformities. With osteotomy of the proximal tibia, there is a risk of altering the tibial slope in the sagittal plane. Surgical techniques continue to evolve with trends towards procedure reproducibility and simplification. We evaluated a modification of the Arthrex iBalance technique in 18 paired cadaveric knees with the goals of maintaining sagittal slope, increasing procedure efficiency, and decreasing use of intraoperative fluoroscopy. Methods Nine paired cadaveric knees (18 legs) underwent iBalance medial opening wedge high tibial osteotomies. In each pair, the right knee underwent an HTO using the modified technique, while all left knees underwent the traditional technique. Independent observers evaluated postoperative factors including tibial slope, placement of hinge pin, and implant placement. Specimens were then dissected to evaluate for any gross muscle, nerve or vessel injury. Results Changes to posterior tibial slope were similar using each technique. The change in slope in traditional iBalance technique was -0.3° ±2.3° and change in tibial slope using the modified iBalance technique was -0.4° ±2.3° (p=0.29). Furthermore, we detected no differences in posterior tibial slope between preoperative and postoperative specimens (p=0.74 traditional, p=0.75 modified). No differences in implant placement were detected between traditional and modified techniques. (p=0.85). No intraoperative iatrogenic complications (i.e. lateral cortex fracture, blood vessel or nerve injury) were observed in either group after gross dissection. Discussion & Conclusions Alterations in posterior tibial slope are associated with HTOs. Both traditional and modified iBalance techniques appear reliable in coronal plane corrections without changing posterior tibial slope. The present modification of the Arthrex iBalance technique may increase the efficiency of the operation and decrease radiation exposure to patients without compromising implant placement or global knee alignment. PMID:25328454
Chiari Malformation and Hydrocephalus Masking Neurocysticercosis.
Rajpal, Sharad; Tomberlin, Colson; Bauer, Andrew; Forsythe, Robert C; Burneikiene, Sigita
2018-06-01
Various diagnostic characteristics associated with neurocysticercosis have been well studied; however, their potential to be implicated in other differential diagnoses has not been well demonstrated. We report the case of a 55-year-old Hispanic man who underwent a Chiari decompression surgery, which was complicated with hydrocephalus. Despite a ventriculoperitoneal shunt placement, he continued to have headaches and was soon found to have several skull base subarachnoid lesions, which were later diagnosed as the sequelae of an active neurocysticercosis infection. This case report highlights the importance of overlapping symptoms between diseases in a short temporal context. Copyright © 2018 Elsevier Inc. All rights reserved.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures. Images Fig. 3. PMID:758853
Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J
2017-05-18
To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip stitched, quadrupled and shaped to match the diameter of the prepared femoral tunnel. If the diameter of the patient's autologous hamstring graft is insufficient to fill the prepared femoral tunnel, the autograft may be supplemented with an allograft. The remainder of the reconstruction is performed according to surgeon preference. The presence of retained hardware presents a challenge for surgeons treating patients with knee instability. In cruciate ligament reconstruction, distal femoral and proximal tibial implants hardware may confound tunnel placement, making removal of hardware necessary, unless techniques are adopted to allow for anatomic placement of the graft. This report demonstrates how the femoral tunnel can be created using the anteromedial portal instead of a transtibial approach for reconstruction of the ACL.
Shin, Young-Soo; Han, Seung-Beom; Hwang, Yeok-Ku; Suh, Dong-Won; Lee, Dae-Hee
2015-05-01
We aimed to compare posterior cruciate ligament (PCL) tibial tunnel location after tibial guide insertion medial (between the PCL remnant and the medial femoral condyle) and lateral (between the PCL remnant and the anterior cruciate ligament) to the PCL stump as determined by in vivo 3-dimensional computed tomography (3D-CT). Tibial tunnel aperture location was analyzed by immediate postoperative in vivo CT in 66 patients who underwent single-bundle PCL reconstruction, 31 by over-the-PCL and 35 by under-the-PCL tibial guide insertion techniques. Tibial tunnel positions were measured in the medial to lateral and proximal to distal directions of the posterior proximal tibia. The center of the tibial tunnel aperture was located more laterally (by 2.7 mm) in the over-the-PCL group than in the under-the-PCL group (P = .040) and by a relative percentage (absolute value/tibial width) of 3.2% (P = .031). Tibial tunnel positions in the proximal to distal direction, determined by absolute value and relative percentage, were similar in the 2 groups. Tibial tunnel apertures were located more laterally after lateral-to-the-PCL tibial guide insertion than after medial-to-the-PCL tibial guide insertion. There was, however, no significant difference between these techniques in distance from the joint line to the tibial tunnel aperture. Insertion lateral to the PCL stump may result in better placement of the PCL in its anatomic footprint. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Development of a cerebrospinal fluid lateral reservoir model in rhesus monkeys (Macaca mulatta).
Lester McCully, Cynthia M; Bacher, John; MacAllister, Rhonda P; Steffen-Smith, Emilie A; Saleem, Kadharbatcha; Thomas, Marvin L; Cruz, Rafael; Warren, Katherine E
2015-02-01
Rapid, serial, and humane collection of cerebrospinal fluid (CSF) in nonhuman primates (NHP) is an essential element of numerous research studies and is currently accomplished via two different models. The CSF reservoir model (FR) combines a catheter in the 4th ventricle with a flexible silastic reservoir to permit circulating CSF flow. The CSF lateral port model (LP) consists of a lateral ventricular catheter and an IV port that provides static access to CSF and volume restrictions on sample collection. The FR model is associated with an intensive, prolonged recovery and frequent postsurgical hydrocephalus and nonpatency, whereas the LP model is associated with an easier recovery. To maximize the advantages of both systems, we developed the CSF lateral reservoir model (LR), which combines the beneficial features of the 2 previous models but avoids their limitations by using a reservoir for circulating CSF flow combined with catheter placement in the lateral ventricle. Nine adult male rhesus monkeys were utilized in this study. Pre-surgical MRI was performed to determine the coordinates of the lateral ventricle and location of choroid plexus (CP). The coordinates were determined to avoid the CP and major blood vessels. The predetermined coordinates were 100% accurate, according to MRI validation. The LR system functioned successfully in 67% of cases for 221 d, and 44% remain functional at 426 to 510 d postoperatively. Compared with established models, our LR model markedly reduced postoperative complications and recovery time. Development of the LR model was successful in rhesus macaques and is a useful alternative to the FR and LP methods of CSF collection from nonhuman primates.
Changes in in vivo knee contact forces through gait modification.
Kinney, Allison L; Besier, Thor F; Silder, Amy; Delp, Scott L; D'Lima, Darryl D; Fregly, Benjamin J
2013-03-01
Knee osteoarthritis (OA) commonly occurs in the medial compartment of the knee and has been linked to overloading of the medial articular cartilage. Gait modification represents a non-invasive treatment strategy for reducing medial compartment knee force. The purpose of this study was to evaluate the effectiveness of a variety of gait modifications that were expected to alter medial contact force. A single subject implanted with a force-measuring knee replacement walked using nine modified gait patterns, four of which involved different hiking pole configurations. Medial and lateral contact force at 25, 50, and 75% of stance phase, and the average value over all of stance phase (0-100%), were determined for each gait pattern. Changes in medial and lateral contact force values relative to the subject's normal gait pattern were determined by a Kruskal-Wallis test. Apart from early stance (25% of stance), medial contact force was most effectively reduced by walking with long hiking poles and wide pole placement, which significantly reduced medial and lateral contact force during stance phase by up to 34% (at 75% of stance) and 26% (at 50% of stance), respectively. Although this study is based on data from a single subject, the results provide important insight into changes in medial and lateral contact forces through gait modification. The results of this study suggest that an optimal configuration of bilateral hiking poles may significantly reduce both medial and lateral compartment knee forces in individuals with medial knee osteoarthritis. Copyright © 2012 Orthopaedic Research Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ammar, Thoraya; Rio, Alan; Ampong, Mary Ann
2010-06-15
Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, withmore » modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopera, Jorge E., E-mail: jloper@lsuhsc.edu; Kirsch, David; Qian Zhong
2005-05-15
The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiogramsmore » were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.« less
Eichholz, Kurt M; Hitchon, Patrick W; From, Aaron; Rubenbauer, Paige; Nakamura, Satoshi; Lim, Tae Hong; Torner, James
2004-07-01
Thoracolumbar burst fractures frequently require surgical intervention. Although the use of either anterior or posterior instrumentation has advantages and disadvantages, there have been few studies in which these two approaches have been compared biomechanically. Ten human cadaveric spines were subjected to subtotal L-3 corpectomy. In five spines placement of L-3 wooden strut grafts with lateral L2-4 dual rod and screw instrumentation was performed. Five other spines underwent L1-5 pedicle screw fixation. The spines were fatigued between steps of the experiment. The spines were load tested with pure moments of 1.5, 3, 4.5, and 6 Nm in the intact state and after placement of instrumentation in six degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In axial rotation posterior instrumentation significantly increased spinal rigidity compared with that of the intact state, whereas anterior instrumentation did not. Combined anterior-posterior instrumentation did not significantly increase the rigidity of the spine when compared with anterior or posterior instrumentation alone. Posterior instrumentation alone provided a greater reduction in angular rotation compared with anterior instrumentation alone in all degrees of freedom; however, statistical significance was achieved only in extension at 6 Nm. The increased rigidity provided by pedicle screw instrumentation compared with the intact state or with anterior instrumentation is due to the longer construct spanning five levels and the three-column engagement of the pedicle screws. The decision to use anterior or posterior instrumentation should be based on the clinical necessity of canal decompression and correction of angulation.
Lopera, Jorge E; Kirsch, David; Qian, Zhong; Ruiz, Bernardo; Brazzini, Augusto; Gonzales, Arturo; Castaneda-Zuniga, Wilfrido
2005-01-01
The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiograms were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.
Endoscopically placed nitinol stents for pediatric tracheal obstruction.
Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M
2002-11-11
To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland Ltd.
Arthroscopy Up to Date: Anterior Cruciate Ligament Anatomy.
Schillhammer, Carl K; Reid, John B; Rister, Jamie; Jani, Sunil S; Marvil, Sean C; Chen, Austin W; Anderson, Chris G; D'Agostino, Sophia; Lubowitz, James H
2016-01-01
To categorize and summarize up-to-date anterior cruciate ligament (ACL) research published in Arthroscopy and The American Journal of Sports Medicine and systematically review each subcategory, beginning with ACL anatomy. After searching for "anterior cruciate ligament" OR "ACL" in Arthroscopy and The American Journal of Sports Medicine from January 2012 through December 2014, we excluded articles more pertinent to ACL augmentation; open growth plates; and meniscal, chondral, or multiligamentous pathology. Studies were subcategorized for data extraction. We included 212 studies that were classified into 8 categories: anatomy; basic science and biomechanics; tunnel position; graft selection; graft fixation; injury risk and rehabilitation; practice patterns and outcomes; and complications. Anatomic risk factors for ACL injury and post-reconstruction graft failure include a narrow intercondylar notch, low native ACL volume, and increased posterior slope. Regarding anatomic footprints, the femoral attachment is 43% of the proximal-to-distal lateral femoral condylar length whereas the posterior border of the tendon is 2.5 mm from the articular margin. The tibial attachment of the ACL is two-fifths of the medial-to-lateral interspinous distance and 15 mm anterior to the posterior cruciate ligament. Anatomic research using radiology and computed tomography to evaluate ACL graft placement shows poor interobserver and intraobserver reliability. With a mind to improving outcomes, surgeons should be aware of anatomic risk factors (stenotic femoral notch, low ligament volume, and increased posterior slope) for ACL graft failure, have a precise understanding of arthroscopic landmarks identifying femoral and tibial footprint locations, and understand that imaging to evaluate graft placement is unreliable. Level III, systematic review of Level III evidence. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Santarpia, Giuseppe; Passafaro, Francesco; Pasceri, Eugenia; Mongiardo, Annalisa; Curcio, Antonio; Indolfi, Ciro
2018-05-01
Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complication and its diagnosis is not always easy and often misunderstood. Thromboembolic events are frequently associated with this procedural complication. Percutaneous lead extraction should be performed when diagnosis is made early after device implantation while long-life oral anticoagulation is a wise option when the diagnosis is delayed and the lead is not removed. A 65-year-old man affected by dilated cardiomyopathy, previously treated with a percutaneous mitral valve repair, with 2 MitraClip devices, and later with dual chamber cardioverter/defibrillator implantation, returned in outpatient clinics 2 months after discharge for deterioration of dyspnea; transthoracic echocardiography revealed that the shock lead had been accidentally placed in the apex of the left ventricle. The unintentional lead malposition through the iatrogenic atrial septal defect and its presence into the mitral valve orifice, together with the 2 clip devices implanted, generated an acceleration of transvalvular diastolic flow, determining a moderate stenosis of the mitral valve, as well as promoting a worsening of the degree of valvular regurgitation. Oral anticoagulation therapy was started and a mechanical lead extraction was percutaneously performed. A new defibrillator lead was later appropriately positioned in the apex of the right ventricle. The patient was discharged 3 days after intervention and the follow-up, performed 1 month after discharge, was uneventful. Complex interventional procedures and implantation of multiple devices can increase procedural troubles and the risk of mechanical complications related to pacemaker/defibrillator implantation. Careful observation of the QRS complex morphology on the electrocardiogram (ECG), during paced rhythm, and the achievement of the echocardiographic examination, in the postprocedural phase, allow an early diagnosis of lead malposition.
Barth, Johannes; Boutsiadis, Achilleas; Neyton, Lionel; Lafosse, Laurent; Walch, Gilles
2017-10-01
One of the factors that can affect the success of the Latarjet procedure is accurate coracoid graft (CG) placement. The use of a guide can improve placement of the CG and screw positioning in the sagittal and axial planes as compared with the classic open ("freehand") technique. Cohort study; Level of evidence, 2. A total of 49 patients who underwent a Latarjet procedure for the treatment of recurrent anterior shoulder instability were prospectively included; the procedure was performed with the freehand technique in 22 patients (group 1) and with use of a parallel drill guide during screw placement in 27 patients (group 2). All patients underwent a postoperative computed tomography scan with the same established protocol. The scans were used to evaluate and compare the position of the CG in the sagittal and axial planes, the direction of the screws (α angle), and overall contact of the graft with the anterior surface of the glenoid after the 2 surgical techniques. The CG was placed >60% below the native glenoid equator in 23 patients (85.2%) in group 2, compared with 14 patients (63.6%) in group 1 ( P = .004). In the axial plane, the position of the CG in group 2 patients was more accurate (85.2% and 88.9% flush) at the inferior and middle quartiles of the glenoid surface ( P = .012 and .009), respectively. Moreover, with the freehand technique (group 1), the graft was in a more lateral position in the inferior and middle quartiles ( P = .012 and .009, respectively). No differences were found between groups 1 and 2 regarding the mean α angle of the superior (9° ± 4.14° vs 11° ± 6.3°, P = .232) and inferior (9.5° ± 6° vs 10° ± 7.5°, P = .629) screws. However, the mean contact angle (angle between the posterior coracoid and the anterior glenoid surface) with the freehand technique (3.8° ± 6.8°) was better than that of the guide (8.55° ± 8°) ( P = .05). Compared with the classic freehand operative technique, the parallel drill guide can ensure more accurate placement of the CG in the axial and sagittal planes, although with inferior bone contact.
Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.
Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs
2012-08-01
Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
Tracheal Malplacement of the King LT Airway May Be an Important Cause of Prehospital Device Failure.
Driver, Brian E; Plummer, David; Heegaard, William; Reardon, Robert F
2016-12-01
The King LT airway (King Systems, Noblesville, IN) is a popular extraglottic device that is widely used in the prehospital setting. We report a case of tracheal malplacement of the King airway with a severe kink in the distal tube. A 51-year-old unhelmeted motorcyclist collided with a freeway median and was obtunded when paramedics arrived. After bag mask ventilation, a King airway was placed uneventfully and the patient was transported to the emergency department. Because of the concern for an unstable cervical spine injury, a lateral cervical spine radiograph was obtained on arrival. No cervical injury was seen, but the King airway was noted to be malplaced; the King airway passed through the laryngeal inlet and became lodged on the anterior trachea, creating an acute kink between the two balloons. After reviewing the radiograph, ventilations were reassessed and remained adequate. Both balloons were deflated, and the King airway was removed; the patient was orotracheally intubated without complication. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: The King airway is a valuable prehospital airway that can be placed quickly and blindly with high success rates by inexperienced providers; the King airway, however, is not without complication. Ventilation was not impaired in this patient, but tracheal malplacement may be an important cause of prehospital device failure. If a first placement attempt of a King airway device fails, it is reasonable to reattempt King airway placement with a new, unkinked device before abandoning King airway placement. Copyright © 2016 Elsevier Inc. All rights reserved.
Luites, J W H; Wymenga, A B; Blankevoort, L; Kooloos, J M G; Verdonschot, N
2011-01-01
Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through statistical shape analysis of the ACL insertion, with respect to the anteromedial (AM) and posterolateral (PL) bundles. The ligament insertion data, together with the osteocartilage edge on the lateral notch, were mapped onto a cylinder fitted to the intercondylar notch surface (n = 33). Anatomic variation, in terms of standard variation of the positions of the ligament centers in the template, was within 2.2 mm. The resulting template was programmed in a computer-assisted navigation system for ACL replacement and its accuracy and precision were determined on 31 femora. It was found that with the navigation system the AM and PL tunnels could be positioned with an accuracy of 2.5 mm relative to the anatomic insertion centers; the precision was 2.4 mm. This system consists of a template that can easily be implemented in 3D computer navigation software. Requiring no preoperative images and planning, the system provides adequate accuracy and precision to position the entrance of the femoral tunnels for anatomical single- or double-bundle ACL reconstruction.
Inferior alveolar nerve transposition in conjunction with implant placement.
Ferrigno, Nicola; Laureti, Mauro; Fanali, Stefano
2005-01-01
The aim of this prospective study was to determine the incidence of neurosensory disturbance and the cumulative survival and success rates of ITI solid-screw implants placed in conjunction with an inferior alveolar nerve (IAN) transposition technique. 46 ITI implants were placed in 15 patients following transposition of the IAN. In 4 patients nerve transpositioning was performed bilaterally, so a total of 19 IAN mobilization surgeries were performed. Neurosensory dysfunction was objectively evaluated by using light touch (LT), pain (PT), and 2-point discrimination (2-DT) tests. In addition, patients were asked to answer a short questionnaire to investigate individual feelings of discomfort and advantages related to this surgical technique. The mean follow-up period was 49.1 months (range, 12 to 78 months). The cumulative implant survival and success rates were 95.7% and 90.5%, respectively. Only 2 implants were lost. Neurosensory disturbance (ie, disturbance registered by the LT, PT, and 2-DT tests) was experienced in 4 of 19 cases. However, at the time of data analysis (12 to 78 months after surgery), all patients indicated that they would go through the surgery again. The IAN transposition technique, when used in the severely atrophied posterior mandible, allowed placement of implants with adequate length and good initial stabilization. All patients felt that they had received significant benefits from their new prostheses. Based on the results of the present study, it can be concluded that lateral nerve transposition can be used as a surgical procedure to enable ITI implant placement in the severely resorbed posterior mandible.
Yamahata, Hitoshi; Tokimura, Hiroshi; Hirahara, Kazuho; Ishii, Takeshi; Mori, Masanao; Hanaya, Ryosuke; Arita, Kazunori
2014-08-01
Introduction The resection of petroclival meningiomas presents great neurosurgical challenges. Although multiple surgical approaches have been developed, the retrosigmoid route tends to be used to address tumors that are predominantly located in the posterior fossa. Our modification of the lateral suboccipital retrosigmoid approach with the placement of a tentorial incision yields good visualization of the supratentorial part of the tumor around the midbrain. Methods We treated four patients, one with primary and three with recurrent petroclival meningioma, by our modified approach. After lateral suboccipital craniotomy, the infratentorial part of the tumor was removed after detaching it from the tentorial surface. The cerebellar tentorium was then carefully incised from the supracerebellar angle, taking care not to damage the superior cerebellar artery and trochlear nerve. Results The operative field surrounding the midbrain was widened by this procedure, and safe dissection of the tumor from the brainstem and other neurovascular structures was performed with direct observation of the interface. Conclusions Our approach is a useful modification of the retrosigmoid approach to petroclival meningiomas. It facilitates the safe resection of the supratentorial part of the tumor in the ambient cistern behind the tentorium.
Adjustable sutures: experimental assessment of final muscle position.
Climenhaga, H W; Pearce, W G
1984-08-01
The likelihood of forward "creep" of muscles recessed with the use of adjustable loops of suture in the correction of strabismus was investigated. Twelve orthotropic dogs underwent both regular and loop recessions of the lateral and medial rectus muscles; the data for two of the dogs were excluded because of loss of muscles. Three months later it was found that in the majority of cases the recessed muscles had minimally advanced from the position of surgical placement. Although the type of recession made little difference to the results, the mean forward creep was much greater for the medial rectus muscles (1.55 +/- 0.68 mm [p less than 0.01] and 2.00 +/- 2.44 mm [p = 0.09] for those undergoing regular and loop recessions respectively) than for the lateral rectus muscles (0.35 +/- 0.58 mm and 0.60 +/- 0.62 mm respectively). During the operations the amount of contraction of the medial rectus muscle had been noted to vary. It is likely that in some instances the tension on the suture loops was insufficient to hold them taut, and the muscles therefore adhered to the sclera at variable sites. Hence, adequate intrinsic muscle tone may be important for predictable clinical results of loop recession.
Ochs, Bjoern Gunnar; Stuby, Fabian Maria; Ateschrang, Atesch; Stoeckle, Ulrich; Gonser, Christoph Emanuel
2014-10-01
Percutaneous screw placement can be used for minimally invasive treatment of none or minimally displaced fractures of the anterior column. The complex pelvic geometry can pose a major challenge even for experienced surgeons. The present study examined the preformed bone stock of the anterior column in 260 hemipelvises (130 male and 130 female). Screws were virtually implanted using iPlan(®) CMF (BrainLAB AG, Feldkirchen, Germany); the maximal implant length and the maximal implant diameter were assessed. The study showed, that 6.5mm can generally be used in men; in women however individual planning is essential in regard to the maximal implant diameter since we found that in 15.4% of women, screws with a diameter less than 6.5mm were necessary. The virtual analysis of the preformed bone stock corridor of the anterior column showed two constrictions of crucial clinical importance. These can be found after 18% and 55% (men) respectively 16% and 55% (women) measured from the entry point along the axis of the implant. The entry point of the retrograde anterior column screw in our collective was located lateral of tuberculum pubicum at the level of the superior-medial margin of foramen obturatum. In female patients, the entry point was located significantly more lateral of symphysis and closer to the cranial margin of ramus superior ossis pubis. The mean angle between the screw trajectory and the anterior pelvic plane in sagittal section was 31.6 ± 5.5°, the mean angle between the screw trajectory and the midsagittal plane in axial section was 55.9 ± 4.6° and the mean angle between the screw trajectory and the midsagittal plane in coronal section was 42.1 ± 3.9° with no significant deviation between both sexes. The individual angles formed by the screw trajectory and the anterior pelvic and midsagittal plane are independent from anthropometric parameters sex, age, body length and weight. Therefore, they can be used for orientation in lag screw placement keeping in mind that the entry point differs in both sexes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cheema, Tahseen; Salas, Christina; Morrell, Nathan; Lansing, Letitia; Reda Taha, Mahmoud M; Mercer, Deana
2012-04-01
Radial subluxation and cartilage thinning have been associated with initiation and accelerated development of osteoarthritis of the trapeziometacarpal joint. Few investigators have reported on the benefits of opening wedge trapezial osteotomy for altering the contact mechanics of the trapeziometacarpal joint as a possible deterrent to the initiation or progression of osteoarthritis. We used cadaveric specimens to determine whether opening wedge osteotomy of the trapezium was successful in reducing radial subluxation of the metacarpal base and to quantify the contact area and pressure on the trapezial surface during simulated lateral pinch. We used 8 fresh-frozen specimens in this study. The flexor pollicis longus, abductor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis brevis/opponens pollicis tendons were each loaded to simulate the thumb in lateral pinch position. We measured radial subluxation from anteroposterior radiographs before and after placement of a 15° wedge. We used real-time sensors to analyze contact pressure and contact area distribution on the trapezium. Center of force in the normal joint under lateral pinch loading was primarily located in the dorsal region of the trapezium. After wedge placement, contact pressure increased in the ulnar-dorsal region by 76%. Mean contact area increased in the ulnar-dorsal region from 0.05 to 0.07 cm(2), and in the ulnar-volar region from 0.003 to 0.024 cm(2). The average reduction in joint subluxation was 64%. The 15° opening wedge osteotomy of the trapezium reduced radial subluxation of the metacarpal on the trapezium and increased contact pressure and contact area away from the diseased compartments of the trapezial surface. Trapezial osteotomy addresses the 2 preeminent theories about the initiation and progression of osteoarthritis. By reducing radial subluxation and altering contact pressure and contact area, trapezial osteotomy may prove an alternative to first metacarpal extension osteotomy or ligament reconstruction in early stages of degenerative arthritis of the trapeziometacarpal joint. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Iwakiri, Kentaro; Kobayashi, Akio; Ohta, Yoichi; Minoda, Yukihide; Takaoka, Kunio; Nakamura, Hiroaki
2017-12-01
The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide. The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators. The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P < .0001). The discrepancies from the targeted angles were 3.5° ± 3.1° for the inclination angle and 4.6° ± 3.4° for the anteversion angle in the conventional group and 2.3° ± 2.3° and 3.2° ± 2.7°, respectively, in the mechanical navigator group (P = .020, P = .012). The mechanical cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position. Copyright © 2017 Elsevier Inc. All rights reserved.
Dagassan-Berndt, Dorothea C; Zitzmann, Nicola U; Walter, Clemens; Schulze, Ralf K W
2016-08-01
To evaluate the impact of cone beam computed tomography (CBCT) imaging on treatment planning regarding augmentation procedures for implant placement. Panoramic radiographs and CBCT images of 40 patients requesting single-tooth implants in 59 sites were retrospectively analyzed by six specialists in implantology, and treatment planning was performed. Therapeutic recommendations were compared with the surgical protocol performed initially. Bone height estimation from panoramic radiographs yielded to higher measures and greater variability compared to CBCT. The suggested treatment plan for lateral and vertical augmentation procedures based on CBCT or panoramic radiographs coincided for 55-72% of the cases. A trend to a more invasive augmentation procedure was seen when planning was based on CBCT. Panoramic radiography revealed 57-63% (lateral) vs. 67% (vertical augmentation) congruent plans in agreement with surgery. Among the dissenting sites, there was a trend toward less invasive planning for lateral augmentation with panoramic radiographs, while vertical augmentation requirements were more frequently more invasive when based on CBCT. Vertical augmentation requirements can be adequately determined from panoramic radiographs. In difficult cases with a deficient lateral alveolar bone, the augmentation schedule may better be evaluated from CBCT to avoid underestimation, which occurs more frequently when based on panoramic radiographs only. However, overall, radiographic interpretation and diagnostic thinking accuracy seem to be mainly depending on the opinion of observers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Clinical Performance of Pedo Jacket Crowns in Maxillary Anterior Primary Teeth.
Castro, Aimee; Badr, Sherine B Y; El-Badrawy, Wafa; Kulkarni, Gajanan
2016-09-15
To assess the clinical performance of Pedo Jacket crowns for restoration of carious primary anterior teeth. A total of 129 carious primary incisors and canines of 48 children younger than 71 months of age- were restored with Pedo Jacket crowns and resin-modified glass ionomer cementation. They were assessed for: ease of use; presence of recurrent decay; wear; partial or complete loss of the crown; color stability; gingival health; and overall clinical success over a 12-month follow-up. The patient's behavior at the restorative appointment during crown placement was also assessed. An overall clinical success of 89.5 percent of the teeth in 87.3 percent of the children was seen one year later. The crowns were easy to use, even in uncooperative children. The color stability, wear, plaque accumulation, and gingival health were acceptable. Discoloration, wear, or complete loss of the crown were found in 13.1 percent, 5.4 percent, and 7.6 percent of children, respectively. Although not statistically significant, failures were associated with poor patient cooperation at the time of crown placement, poor oral hygiene, or operator error. Pedo Jacket crowns are a viable treatment alternative for carious maxillary primary anterior teeth.
Foot Placement Modification for a Biped Humanoid Robot with Narrow Feet
Hattori, Kentaro; Otani, Takuya; Lim, Hun-Ok; Takanishi, Atsuo
2014-01-01
This paper describes a walking stabilization control for a biped humanoid robot with narrow feet. Most humanoid robots have larger feet than human beings to maintain their stability during walking. If robot's feet are as narrow as humans, it is difficult to realize a stable walk by using conventional stabilization controls. The proposed control modifies a foot placement according to the robot's attitude angle. If a robot tends to fall down, a foot angle is modified about the roll axis so that a swing foot contacts the ground horizontally. And a foot-landing point is also changed laterally to inhibit the robot from falling to the outside. To reduce a foot-landing impact, a virtual compliance control is applied to the vertical axis and the roll and pitch axes of the foot. Verification of the proposed method is conducted through experiments with a biped humanoid robot WABIAN-2R. WABIAN-2R realized a knee-bended walking with 30 mm breadth feet. Moreover, WABIAN-2R mounted on a human-like foot mechanism mimicking a human's foot arch structure realized a stable walking with the knee-stretched, heel-contact, and toe-off motion. PMID:24592154
Stiles, P J; Drake, Rachel M; Helmer, Stephen D; Bjordahl, Paul M; Haan, James M
2014-06-01
When retained hemothorax occurs, video-assisted thoracoscopy or thoracotomy is performed, but recently, tissue plasminogen activator (tPA) has been used. This study evaluated intrapleural tPA use for retained traumatic hemothoraces. A retrospective review was conducted of trauma patients treated with intrapleural tPA for retained hemothorax. Data included demographics, past medical and surgical histories, injury details, treatment details, and outcomes. Seven patients (median age = 47 years, male = 6, blunt trauma = 6) met study criteria. All patients received a chest tube. Six patients later received computed tomography-guided drains for tPA infusion. Number of tPA treatments per patient varied from 1 to 5. Median total tPA dosage was 24 mg. Median time from injury to chest tube placement was 11 days and from chest tube placement to first tPA treatment was 4 days. No patients required a video-assisted thoracoscopy; however, 1 patient required thoracotomy. There were no deaths or bleeding complications attributed to intrapleural tPA. Although future studies are needed to identify optimum treatment guidelines, intrapleural tPA appears to be a safe and efficacious treatment option. Copyright © 2014 Elsevier Inc. All rights reserved.
D'Cunha, Craig; Plakiotis, Christos; Macfarlane, Stephen; Moss, Francine; Reddy, Murali; Singh, Dhiren; Tofler, David; White, Erica; O'Connor, Daniel W
2016-03-01
The aim of the study was to determine whether depressed aged inpatients treated with brief pulse unilateral electroconvulsive therapy (ECT) differed from those treated with bilateral (bitemporal or bifrontal) ECT with respect to numbers of treatments, length of hospital admission, changes in scores on depression and cognitive scales, and serious adverse effects. An audit of routinely collected data regarding 221 acute ECT courses in 7 public aged psychiatry services in Victoria, Australia. Patients given unilateral, bifrontal, and bitemporal treatments were similar with respect to personal, clinical, and treatment characteristics. Most treatments were administered in line with local clinical guidelines and were rated as effective. Psychiatrists preferred unilateral ECT in the first instance with stimulus dosing based on patients' seizure thresholds. Approximately a quarter of unilateral courses were switched later to bitemporal placement, most probably because of insufficient progress. Bilateral treatments were associated with a larger number of treatments, less improvement in scores on mood and cognitive scales, and more refusals to continue treatment than unilateral-only ECT. Brief pulse unilateral ECT proved more effective than bitemporal and bifrontal ECT for most aged patients, especially when coupled with stimulus dosing based on seizure threshold.
Foot placement modification for a biped humanoid robot with narrow feet.
Hashimoto, Kenji; Hattori, Kentaro; Otani, Takuya; Lim, Hun-Ok; Takanishi, Atsuo
2014-01-01
This paper describes a walking stabilization control for a biped humanoid robot with narrow feet. Most humanoid robots have larger feet than human beings to maintain their stability during walking. If robot's feet are as narrow as humans, it is difficult to realize a stable walk by using conventional stabilization controls. The proposed control modifies a foot placement according to the robot's attitude angle. If a robot tends to fall down, a foot angle is modified about the roll axis so that a swing foot contacts the ground horizontally. And a foot-landing point is also changed laterally to inhibit the robot from falling to the outside. To reduce a foot-landing impact, a virtual compliance control is applied to the vertical axis and the roll and pitch axes of the foot. Verification of the proposed method is conducted through experiments with a biped humanoid robot WABIAN-2R. WABIAN-2R realized a knee-bended walking with 30 mm breadth feet. Moreover, WABIAN-2R mounted on a human-like foot mechanism mimicking a human's foot arch structure realized a stable walking with the knee-stretched, heel-contact, and toe-off motion.
A modified fluid percussion device.
Yamaki, T; Murakami, N; Iwamoto, Y; Yoshino, E; Nakagawa, Y; Ueda, S; Horikawa, J; Tsujii, T
1994-10-01
This report examines a modified fluid percussion device with specific improvements made to address deficiencies found in previously reported devices. These improvements include the use of a cylindrical saline reservoir made of stainless steel, placement of the reservoir in a 15-degree head-up position for the easy release of air bubbles, placement of the fluid flushing outlet and the pressure transducer close to the piston on the same plane, with both perpendicular to the direction of the piston, and adjustable reservoir volume to vary the waveform of the pressure pulse, and a metallic central injury screw secured to the animal's skull over the exposed dura. Using this device, midline fluid percussion (MFP) and lateral fluid percussion (LFP) injuries were performed in 70 rats. Histopathologic findings included diffuse axonal injury in the MFP model and cortical contusion in the LFP model. Survival rate was 41.4% in MFP animals and 100% in LFM animals when the device settings were 178 mm3 of the cylindrical reservoir and 50 degrees-60 degrees in height of the pendulum. Our results suggest that this modified fluid percussion device may offer significant improvements over previously reported fluid percussion models for use in experimental head injury.
Fisher, Philip A; Gunnar, Megan R; Dozier, Mary; Bruce, Jacqueline; Pears, Katherine C
2006-12-01
Young children in foster care are exposed to high levels of stress. These experiences place foster children at risk for poor social, academic, and mental heath outcomes. The role of adverse events in stimulating neurobiological stress responses presumably plays a role in shaping neural systems that contribute to these problems. Systematic and developmentally well-timed interventions might have the potential to change developmental trajectories and promote resilience. Moreover, understanding how specific dimensions of early adversity affect underlying stress response systems and how alterations in these systems are related to later psychosocial outcomes might facilitate more precise and targeted interventions. Data are drawn from two ongoing randomized trials involving foster infants/toddlers and preschoolers. Consistent with prior animal models of early adversity, these studies have shown that early adversity-particularly neglect, younger age at first foster placement, and higher number of placements-is associated with altered hypothalamic-pituitary-adrenal (HPA) axis function. The interventions under investigation have produced evidence that it is possible to impact many areas that have been negatively affected by early stress, including HPA axis activity, behavior, and attachment to caregivers.
Flank and Lumbar Hernia Repair.
Beffa, Lucas R; Margiotta, Alyssa L; Carbonell, Alfredo M
2018-06-01
Flank and lumbar hernias are challenging because of their rarity and anatomic location. Several challenges exist when approaching these specific abdominal wall defects, including location, innervation of the lateral abdominal wall musculature, and their proximity to bony landmarks. These hernias are confined by the costal margin, spine, and pelvic brim, which makes closure of the defect, including mesh placement, difficult. This article discusses the anatomy of lumbar and flank hernias, the various etiologies for these hernias, and the procedural steps for open and robotic preperitoneal approaches. The available clinical evidence regarding outcomes for various repair techniques is also reviewed. Copyright © 2018 Elsevier Inc. All rights reserved.
The friction free osteotome technique: introduction of a modified approach.
Thalmair, Tobias; Fickl, Stefan; Bolz, Wolfgang; Wachtel, Hannes
2009-01-01
The current literature suggests that the bone-condensing approach while performing internal sinus floor elevation may not be beneficial for the future implant site. Furthermore, even with refined procedures, a predictable and controlled infraction of the sinus floor prior to graft placement still seems to be technique sensitive. In this context, the present article presents a modified technique along with the use of parallel osteotomes devoid of any contact to the lateral osteotomy wall. Therefore, compression of the adjacent bone will be avoided and the tactility of the site for the surgeon will be preserved as the osteotome is solely in contact with the subsinus cortex.
Conservative management of pyothorax in an Amur tiger (Panthera tigris altaica).
Schrader, Gabby M; Whiteside, Douglas P; Slater, Owen M; Black, Sandra R
2012-06-01
Therapy for pyothorax, or pleural empyema, has not been described for large felids. This case describes the successful treatment of pyothorax in a captive, large felid. A 15-yr-old multiparous, female Amur tiger (Panthera tigris altaica) presented with nonspecific clinical signs caused by an insidious onset of pyothorax. Management of pyothorax cases in companion animals often involves thoracostomy tube placement with recurrent drainage of the pleural cavity, intensive supportive care, and monitoring. In this case, conservative management was elected because hospitalization was not a viable option. Thoracocentesis was performed to drain as much fluid from the chest cavity as possible, yielding more than 1.3 L. Corynebacterium sp. and unidentified anaerobic gram-positive cocci were cultured. Treatment included cefovecin subcutaneously, oral antibiotic therapy with clindamycin and marbofloxacin, meloxicam, and restricted exercise by minimizing access to the main exhibit. Significant improvement was noted clinically and radiographically 6 wk later, and no relapses were noted in the following weeks. An examination 11.5 mo later confirmed resolution.
High Pressure Rotary Shaft Sealing Mechanism
Dietle, Lannie; Gobeli, Jeffrey D.
2001-05-08
A laterally translatable pressure staged rotary shaft sealing mechanism having a seal housing with a shaft passage therein being exposed to a fluid pressure P1 and with a rotary shaft being located within the shaft passage. At least one annular laterally translatable seal carrier is provided. First and second annular resilient sealing elements are supported in axially spaced relation by the annular seal carriers and have sealing relation with the rotary shaft. The seal housing and at least one seal carrier define a first pressure staging chamber exposed to the first annular resilient sealing element and a second pressure staging chamber located between and exposed to the first and second annular resilient sealing elements. A first fluid is circulated to the first pressure chamber at a pressure P1, and a second staging pressure fluid is circulated to the second pressure chamber at a fraction of pressure P1 to achieve pressure staging, cooling of the seals. Seal placement provides hydraulic force balancing of the annular seal carriers.
Mege, D; Louis, G; Berthet, B
2013-01-01
A serious complication of laparoscopic sleeve gastrectomy (LSG) is bleeding that is primarily located along the staples lines. Bleeding may be due to several causes, including hematomas, trocar sites, or visceral pseudo-aneurysms. We reported here a case of bleeding related to a pseudo-aneurysm of the gastro-omental artery. An LSG was performed on a 43-year-old woman (BMI = 46 kg/m2) without apparent surgical complications. Fifteen days later, she was admitted to the emergency department for hematemesis and symptoms of hemorrhagic shock. Abdominal computed tomography angiography revealed blood in the stomach, without a digestive leak, and active bleeding from a pseudo-aneurysm of the gastro-omental artery. An arterial embolisation was performed with the sandwich technique and angiographic guide wires and the placement of several detachable coils. The patient was discharged two days later. We demonstrated for the first time that post-LSG bleeding may involve a pseudo-aneurysm of the gastro-omental artery.
Goniometric reliability in a clinical setting. Shoulder measurements.
Riddle, D L; Rothstein, J M; Lamb, R L
1987-05-01
The purpose of this study was to examine the intratester and intertester reliabilities for clinical goniometric measurements of shoulder passive range of motion (PROM) using two different sizes of universal goniometers. Patients were measured without controlling therapist goniometric placement technique or patient position during measurements. Repeated PROM measurements of shoulder flexion, extension, abduction, shoulder horizontal abduction, horizontal adduction, lateral (external) rotation, and medial (internal) rotation were taken of two groups of 50 subjects each. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .99. The ICCs for the intertester reliability of PROM measurements of horizontal abduction, horizontal adduction, extension, and medial rotation ranged from .26 to .55. The intertester ICCs for PROM measurements of flexion, abduction, and lateral rotation ranged from .84 to .90. Goniometric PROM measurements for the shoulder appear to be highly reliable when taken by the same physical therapist, regardless of the size of the goniometer used. The degree of intertester reliability for these measurements appears to be range-of-motion specific.
Displacement of ureteral orifices following anterior colporrhaphy.
Dain, Lena; Auslander, Ron; Lissak, Arie; Lavie, Ofer; Abramov, Yoram
2010-01-01
It is currently unknown whether ureteral orifices maintain their anatomic location after reconstructive pelvic surgeries. We therefore aimed to assess ureteral orifices' location after anterior colporrhaphy. Between August and December 2007, patients undergoing anterior colporrhaphy for advanced cystocele in our institution underwent cystoscopy with intravenous dye injection and placement of ureteral catheters before and after the surgery. Each ureteral orifice location was marked on an X-Y coordinate on the posterior bladder wall before and after surgery. Thirteen women aged 44-80 years were included in the study. Postoperatively, ureteral orifices were noted to migrate 0.65 +/- 0.3 cm caudally (closer to the urethrovesical junction) (p = 0.002) and 0.32 +/- 0.5 cm laterally (p < 0.05). Anterior colporrhaphy is associated with significant caudal and lateral displacement of both ureteral orifices. These findings are of potential importance for pelvic reconstructive surgeons and may facilitate faster cystoscopic evaluation of ureteral patency postoperatively. They may also have implications on the angle of the preferred optical equipment to be used.
Robertson, William J; Kelly, Bryan T
2008-09-01
This study evaluated 11 arthroscopic portals (4 central, 4 peripheral, and 3 peritrochanteric) with regard to their proximity to neurovascular structures and the extra-articular path taken before entering their intended compartments. We established 11 standard portals in 10 cadaveric hips, under arthroscopic and fluoroscopic visualization, using 3/16-inch Steinmann pins. Each hip was dissected, and the relation of the pins to the pertinent anatomy was recorded to the nearest 1 mm. Only 2 of the 11 portals, the anterior and midanterior portals, came within 2 cm of a neurovascular structure before entering their respective compartments. The anterior portal placed the lateral femoral cutaneous nerve at risk, lying at a mean of 15.4 mm (range, 1 to 28 mm) away. The midanterior portal lies a mean of 19.2 mm (range, 5 to 42 mm) from the ascending branch of the lateral circumflex femoral artery. In addition, a small terminal branch of this artery courses a mean of 14.7 mm (range, 2 to 33 mm) and 10.1 mm (range, 1 to 23 mm) from the anterior portal and midanterior portal, respectively. This study showed that 11 arthroscopic portals can be safely inserted into the central, peripheral, and peritrochanteric compartments of the hip. The midanterior and anterior portals pass in close proximity to a small terminal branch of the ascending lateral circumflex femoral artery. The greatest risk still comes from the proximity of the anterior portal to the lateral femoral cutaneous nerve. However, a slightly more lateral location seems to provide substantial benefits. This study investigated 11 arthroscopic hip portals inserted in a standardized fashion. This knowledge should help surgeons place the necessary portals both safely and accurately.
A linear programming approach for placement of applicants to academic programs.
Kassa, Biniyam Asmare
2013-01-01
This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the new approach allows the college's management to easily incorporate additional placement criteria, if needed. Comparison of our approach against manually constructed placement decisions based on actual data for the 2012/13 academic year suggested that about 93 percent of the placements from our model concur with the actual placement decisions. For the remaining 7 percent of placements, however, the actual placements made by the manual system display inconsistencies of decisions judged against the very criteria intended to guide placement decisions by the college's program management office. Overall, the new approach proves to be a significant improvement over the manual system in terms of efficiency of the placement process and the quality of placement decisions.
Boon Tow, Benjamin Phak; Yue, Wai Mun; Srivastava, Abhishek; Lai, Jenn Ming; Guo, Chang Ming; Wearn Peng, Benedict Chan; Chen, John L T; Yew, Andy K S; Seng, Chusheng; Tan, Seang Beng
2015-10-01
This was a prospective, nonrandomized study. To assess the accuracy of O-arm navigation-based pedicle screw insertion in lumbar degenerative spondylolisthesis and to compare it with free-hand pedicle screw insertion technique in matched population. O-arm navigation is latest in navigation technology that can provide real-time intraoperative images in 3 dimensions while placing the pedicle screws to improve intraoperative pedicle screw accuracy. Degenerative lumbar spondylolisthesis is a locally unstable pathology and placement of pedicle screws can cause increased rotation and translation of the vertebral body. However, is this motion detected by the tracker placed across the unstable segment, is a matter of debate. Inability to detect these positional changes can lead to pedicle perforation while inserting screws using navigation. No study has evaluated the role of O-arm navigation in this patient population. The study population was divided into 2 groups with 19 patients each, one comprising patients who underwent O-arm navigation-based pedicle screw insertion (group 1) and the other comprising patients who underwent free-hand pedicle screw insertion technique (group 2). A total of 152 pedicle screws were implanted in 38 patients for 1-level instrumented fusion for degenerative lumbar spondylolisthesis. Intraoperative 3-dimensional computed tomography scans using the O-arm were obtained for all patients after insertion of pedicle screws. The images were reviewed intraoperatively and postoperatively for the analysis of pedicle breaches. Assessments in either of the group included (i) accuracy of placement of screws; (ii) the rate and direction of perforation; and (iii) the number of segments the perforated screw was away from the navigation tracker. Mean age of patients in group 1 (O-arm navigation-assisted) was 60 years (SD 11.25; range, 37-73 y), whereas in group 2 (free-hand pedicle screw) was 62 years (SD 18.07; range, 36-90 y). Overall anatomic perforation rate was 12.5% (19/152). Individually, group 1 had 14.47% (11/76) of perforations in comparison with 10.53% (8/76) observed in group 2. The difference was not statistically significant. The lateral margin was the most common site of perforation in both group 1 (64%, 7/11) and group 2 (62.5%, 5/8). Functional perforation rate for the series was 3.3% (5/152), with group 1 having 2.63% (2/76) and group 2 having 3.95% (3/76). The rate of perforation (PR) was significantly higher statistically when the tracker was placed 3 or more [PR 37.5% (6/16)] spinal segments away from instrumented segment compared with when it was placed 1 (0%) or 2 [PR 13.89% (5/36)] spinal segments away. Overall, 11 screws (11/152, 7.24%) had grade 2 perforations and had to be revised. No neurological complications were observed in the series. O-arm navigation does not provide any significant advantage over conventional free-hand pedicle screw insertion technique in patients with single-level degenerative spondylolisthesis. The accuracy is dependent on the distance of the tracker from the level of instrumentation. Lateral perforations are more common because of instability at the instrumented level leading to translation and rotation of the vertebral body while placing pedicle screws leading to preferential lateral trajectory. These lateral perforations could not be prevented by using navigation. However, no significant complications were noted in either technique.
Naganobu, Kiyokazu; Hagio, Mitsuyoshi
2007-01-01
To assess the accuracy of the 'hanging drop method' for identifying the extradural space in anaesthetized dogs positioned in sternal or lateral recumbency. Prospective randomized-experimental study. Seventeen clinically healthy adult dogs, 10 females and seven males weighing 8.4-26.2 kg. Dogs were positioned in either sternal (n = 8) or lateral (n = 9) recumbency under general anaesthesia. A 20 SWG spinal needle pre-filled with 0.9% saline was advanced through the skin into the lumbosacral extradural space and the response of the saline drop recorded, i.e. whether it: 1) was aspirated from the hub into the needle; 2) remained within the hub, or 3) moved synchronously with i) spontaneous respiration, ii) heart beat or iii) manual lung inflation. The position of the needle tip was ultimately determined by positive contrast radiography. One dog positioned in lateral recumbency was excluded from the study because bleeding occurred from the needle hub. Saline was aspirated into the needle in seven of eight dogs held in sternal recumbency but in none of the dogs positioned in lateral recumbency. Accurate needle tip placement in the extradural space was confirmed by positive contrast radiography in all dogs. The 'hanging drop' method, when performed with a spinal needle, appears to be a useful technique for identifying the location of the extradural space in anaesthetized medium-sized dogs positioned in sternal, but not in lateral recumbency. The technique may yield 'false negative' results when performed in dogs positioned in sternal recumbency.
Delayed lymphocele formation following lateral lumbar interbody fusion of the spine.
Hey, Hwee Weng Dennis; Wong, Keng Lin; Gatam, Asrafi Rizki; Lim, Joel Louis; Wong, Hee-Kit
2017-05-01
This paper aims to describe the rare post-operative complication of a lymphocele formation after lateral lumbar interbody fusion. The patient in this case was a 76-year-old lady with a 10 year history of low back pain and neurogenic claudication. She had previously underwent multiple spine surgeries for her condition. She presented to our institution for a recurrence of her low back pain and right anterior thigh pain. She then underwent surgery in two stages; first, a mini-open lateral interbody fusion at L3/4 and L4/5; second, posterior instrumentation of T3 to S1 with sagittal spinal deformity correction. The patient recovered uneventfully in the initial post op period and was discharged within 8 days. However, she developed abdominal distension and discomfort 6 months after surgery. MRI and CT scan of her abdomen showed a retroperitoneal fluid collection compressing her left ureter, resulting in hydroureter and hydronephrosis. She was managed with a CT-guided drainage of the fluid collection. Fluid analysis was consistent with a lymphocele. Since the procedure, the patient has been asymptomatic for 2 years. Delayed lymphocele formation is a potential complication of lateral lumbar interbody fusion. When present, it can be managed conservatively with good results. This case suggests that surgeons should have a low threshold to investigate for a lymphocele development post-anterior or lateral lumbar spine surgery. The authors recommend the placement of a post surgical retroperitoneal drain, as it might assist in the early detection of a lymphocele formation.
Attrill, Stacie; McAllister, Sue; Lincoln, Michelle
2016-08-01
Placements provide opportunities for students to develop practice skills in professional settings. Learning in placements may be challenging for culturally and linguistically diverse (CALD) students, international students, or those without sufficient English proficiency for professional practice. This study investigated whether these factors, which are hypothesized to influence acculturation, predict poor placement outcome. Placement outcome data were collected for 854 students who completed 2747 placements. Placement outcome was categorized into 'Pass' or 'At risk' categories. Multilevel binomial regression analysis was used to determine whether being CALD, an international student, speaking 'English as an additional language', or a 'Language other than English at home' predicted placement outcome. In multiple multilevel analysis speaking English as an additional language and being an international student were significant predictors of 'at risk' placements, but other variables tested were not. Effect sizes were small indicating untested factors also influenced placement outcome. These results suggest that students' English as an additional language or international student status influences success in placements. The extent of acculturation may explain the differences in placement outcome for the groups tested. This suggests that learning needs for placement may differ for students undertaking more acculturative adjustments. Further research is needed to understand this and to identify placement support strategies.
25 CFR 26.25 - What constitutes a complete Job Placement Program application?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...
25 CFR 26.25 - What constitutes a complete Job Placement Program application?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...
25 CFR 26.25 - What constitutes a complete Job Placement Program application?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...
25 CFR 26.25 - What constitutes a complete Job Placement Program application?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...
MacDonald, David S; Waterfield, J Douglas
2011-01-01
The detectors (both solid-state sensors and photostimulable phosphor [PSP] plates) used for digital intraoral radiography cannot be autoclaved, and barriers are typically used to prevent the spread of infection. The aim of this study was to determine the effectiveness of a barrier envelope system for PSP plates. Disinfected PSP plates were aseptically inserted into barrier envelopes and placed in a periapical location. One PSP plate was placed in each of 28 patients, and 12 plates in each of 2 volunteers (D.S.M., J.D.W.). After retrieval, each PSP plate was removed from its barrier envelope, immersed in trypticase soy broth and aliquots were plated on trypticase soy agar. Bacterial colonies were counted 2 days later. Fifty-two PSP plates in barrier envelopes were evaluated for contamination. Quality assurance of the PSP plates before clinical placement revealed defects in the integrity of 4 barrier envelopes, caused by forceps-related damage or failure to achieve a uniform seal. These defects allowed substantial contamination. Contamination also occurred as a result of failure to extract the PSP plate from the barrier envelope cleanly. Of the 44 barriers with no obvious defects that were placed by either final-year dental students or a radiologist, only 3 allowed bacterial contamination of the PSP plate. Detectors contained in barrier envelopes remain a potential source of contamination. PSP plates must be disinfected between removal from a contaminated barrier envelope and placement in a new barrier envelope. In addition, placement into the barrier envelope should ideally be carried out under aseptic conditions. Finally, the integrity of each sealed barrier envelope must be verified visually before release to the clinic.
Segal, Ava D; Shofer, Jane B; Klute, Glenn K
2015-11-26
Maintaining balance while walking is challenging for lower limb amputees. The effect of prosthetic foot stiffness on recovery kinetics from an error in foot placement may inform prescription practice and lead to new interventions designed to improve balance. Ten unilateral transtibial amputees were fit with two prosthetic feet with different stiffness properties in random order. After a 3-week acclimation period, they returned to the lab for testing before switching feet. Twelve non-amputees also participated in a single data collection. While walking on an instrumented treadmill, we imposed a repeatable, unexpected medial or lateral disturbance in foot placement by releasing a burst of air at the ankle just before heel strike. Three-dimensional motion capture, ground reaction force and center of pressure (COP) data were collected for two steps prior, the disturbed step and three steps after the disturbance. During undisturbed walking, coronal ankle impulse was lower by 42% for amputees wearing a stiff compared to a compliant foot (p=0.017); however, across steps, both prosthetic recovery patterns were similar compared to the sound limb and non-amputees. Peak coronal hip moment was 15-20% lower for both foot types during undisturbed walking (p<0.001), with less change in response to the medial disturbance (p<0.001) compared to the sound limb and non-amputees. Amputee prosthetic COP excursion was unaffected by the disturbance (2.4% change) compared to the sound limb (59% change; p<0.001) and non-amputees (55% change; p<0.001). These findings imply that a prosthetic foot-ankle system able to contribute to ankle kinetics may improve walking balance among amputees. Published by Elsevier Ltd.
Vierra, Matthew; Mau, Lian Ping; Huynh-Ba, Guy; Schoolfield, John; Cochran, David L
2016-01-01
To evaluate guided bone regeneration outcomes in defects protected with an in situ formed polyethylene glycol (PEG) hydrogel membrane as compared to a non-cross-linked collagen membrane (CM). Four mandibular alveolar ridge defects were created in eight hound dogs. Regenerative procedures were randomly allocated to one of four groups consisting of freeze-dried bone allograft, which is referred to in this study as freeze-dried bone xenograft (FDBX) + PEG, autogenous bone (AB) + PEG, AB + CM, and AB alone. After 8 weeks, titanium dental implants were placed into augmented sites. After 8 weeks of allowed time for osseointegration, the animals were sacrificed to harvest block specimens for bone-to-implant contact (BIC) and ridge width histomorphometric analysis. Polyethylene glycol membranes had an exposure rate of 50% as compared to 12.5% for sites grafted with CM. Regenerative outcomes with respect to implant placement were least favorable for FDBX + PEG which had implants placed in 37.5% of augmented sites compared to 100% implant placement for all other groups. No statistically significant differences were noted between groups for ridge width measurements in implant and non-implant histologic sections (P > 0.05). Buccal BIC (%) values between treatment groups also failed to reach statistical significant difference (FDBX + PEG [60.2 ± 9.4]; AB + PEG [58.8 ± 8.5]; AB + CM [57.9 ± 12.8]; AB [61.0 ± 10.2]). When used in conjunction with FDBX, PEG had unpredictable bone formation and in most cases negatively impacted future implant placement. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wasmer, Kristina; Zellerhoff, Stephan; Köbe, Julia; Mönnig, Gerold; Pott, Christian; Dechering, Dirk G; Lange, Philipp S; Frommeyer, Gerrit; Eckardt, Lars
2017-03-01
Transseptal punctures (TSP) are routinely performed in cardiac interventions requiring access to the left heart. While pericardial effusion/tamponade are well-recognized complications, few data exist on accidental puncture of the aorta and its management and outcome. We therefore analysed our single centre database for this complication. We assessed frequency and outcome of inadvertent aortic puncture during TSP in consecutive patients undergoing ablation procedures between January 2005 and December 2014. During the 10-year period, two inadvertent aortic punctures occurred among 2936 consecutive patients undergoing 4305 TSP (0.07% of patients, 0.05% of TSP) and in one Mustard patient during attempted baffle puncture. The first two patients required left ventricular access for catheter ablation of ventricular tachycardia. In both cases, an 11.5F steerable sheath (inner diameter 8.5F) was accidentally placed in the ascending aorta just above the aortic valve. In the presence of surgical standby, the sheaths were pulled back with a wire left in the aorta. Under careful haemodynamic and echocardiographic observation, this wire was also pulled back 30 min later. None of the patients required a closing device or open heart surgery. None of the patients suffered complications from the accidental aortic puncture and sheath placement. Inadvertent aortic puncture and sheath placement are rare complications in patients undergoing TSP for interventional procedures. Leaving a guidewire in place during the observation period may allow introduction of sheaths or other tools in order to control haemodynamic deterioration. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Romão, Marcia M. A.; Marques, Márcia M.; Cortes, Arthur R. G.; Horliana, Anna C. R. T.; Moreira, Maria S.; Lascala, Cesar A.
2015-06-01
The immediate dental implant placement in the molars region is critical, because of the high amount of bone loss and the discrepancy between the alveolar crest thickness and the dental implant platform. Laser phototherapy (LPT) improves bone repair thus could accelerate the implant placement. Twenty patients were selected for the study. Ten patients were submitted to LPT with GaAlAs diode laser (808nm) during molar extraction, immediately after, 24h, 48h, 72h, 96h and 7 days. The irradiations were applied in contact and punctual mode (100mW, 0.04cm2, 0.75J/cm2, 30s per point, 3J per point). The control group (n=10) received the same treatment; however with the power of the laser off. Forty days later samples of the tissue formed inside the sockets were obtained for further microtomography (microCTs) and histomorphometry analyses. Data were compared by the Student t test, whereas those from the different microCT parameters were compared by the Pearson correlation test (p<0.05). The relative bone volume, as well as area was significantly higher (p<0.001) in the lased than the control group. In the control group there were negative correlations between number and thickness, and between number and separation of trabecula (p<0.01). Between thickness and separation of trabecula the correlation was positive (p<0.01). The laser group showed significant negative correlation between the number and the thickness of trabecula (p<0.01). LPT accelerated bone repair. By the Pearson correlation test it was possible to infer that the lased group presented a more homogeneous trabecular configuration, which would allow earlier dental implant placement.
Chaushu, Gavriel; Mardinger, Ofer; Calderon, Shlomo; Moses, Ofer; Nissan, Joseph
2009-03-01
The simultaneous placement of dental implants during sinus augmentation is advocated in cases in which >or=4 to 5 mm of alveolar bone exists coronally to the sinus floor. The aim of the present study was to assess the survival rate of dental implants placed during sinus augmentation and stabilized by the use of cancellous freeze-dried block allograft. Residual alveolar ridge height
Accuracy of intra-articular injection of the glenohumeral joint: a modified anterior approach.
Jo, Chris Hyunchul; Shin, Young Ho; Shin, Ji Sun
2011-10-01
This study examined the accuracy of our modified anterior approach to the glenohumeral joint using arthrography. Two hundred fifty-six consecutive patients with adhesive capsulitis received the glenohumeral joint injection: a mixture of 1 mL of 40 mg of triamcinolone hexacetonide, 2 mL of 2% lidocaine, 3 mL of contrast medium (Ioxitalamate), and 4 mL of normal saline solution, for a total of 10 mL, through a modified anterior approach. Anteroposterior, lateral, and axial arthrography after each injection was performed to determine the accuracy and patterns of the injection. The injection was judged to be successful if some of the contrast medium was placed within the joint. There were 78 male and 178 female patients, and the mean age was 54 years (range, 28 to 87 years). In 232 of the 256 patients (90.6%), the injection was deemed to have reached the glenohumeral joint, and these cases were considered successful. Among these patients, the contrast medium was shown only in the joint in 189 (73.8%), whereas in 43 (16.8%) it was shown both in and out of the joint. Of the 24 misguided injections, 15 (5.9%) had anterior placement, 6 (2.3%) had posterior placement, and 2 (0.8%) had superior placement, whereas the material was located in all portions outside the joint in 1 (0.4%). This study showed that our modified anterior approach had an accuracy greater than 90% for the intra-articular injection of the glenohumeral joint without radiographic guidance. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Formwork pressure exerted by self-consolidating concrete
NASA Astrophysics Data System (ADS)
Omran, Ahmed Fathy
Self-consolidating concrete (SCC) is an emerging technology that utilizes flowable concrete that eliminates the need for consolidation. The advantages of SCC lie in a remarkable reduction of the casting time, facilitating the casting of congested and complex structural elements, possibility to reduce labor demand, elimination of mechanical vibrations and noise, improvement of surface appearance, producing a better and premium concrete product. The research focussed on capturing existing knowledge and making recommendations for current practice. An experimental program was undertaken at the Universite de Sherbrooke to evaluate the lateral pressure developed by SCC mixtures. A portable devise (UofS2 pressure column) for measuring and predicting lateral pressure and its rate of decay of SCC was developed and validated. The UofS2 pressure column is cast with 0.5 m high fresh concrete and air pressure is introduced from the top to simulate casting depth up to 13 m. Then, develop and implement test method for field evaluation of relevant plastic and thixotropic properties of SCC that affect formwork pressure were done. Portable vane (PV) test based on the hand-held vane test method used to determine the undrained shear strength property of clay soil was the first setup as well as the inclined plane (IP) test. The IP device involves slumping a small concrete cylinder on a horizontal plate and then lifting up the plate at different durations of rest until the slumped sample starts to move. Identifying role of material constituents, mix design, concrete placement characteristics (casting rate, waiting periods between lifts, and casting depth), temperature, and formwork characteristics that have major influence on formwork pressure exerted by SCC were evaluated in laboratory and validated by actual field measurements. Relating the maximum lateral pressure and its rate of decay to the plastic properties of SCC were established. In the analytical part of the research, effective ways to reduce lateral pressure by developing formulation expertise and practical guidelines to lower lateral pressure of SCC were proposed. Various design equations as well as chart diagrams to predict formwork pressure that can be exerted by SCC on column and wall elements were derived and reported. In general, the results obtained show that measured lateral pressure is lower than corresponding hydrostatic pressure. The study has shown that lateral pressure exerted by SCC is closely related to the structural build-up at rest (or thixotropy) of SCC. The latter can be controlled using different mixture proportionings, material constituents, and chemical admixtures. SCC mixture with a high rate of structural build-up at rest can develop low lateral pressure on formwork. Increased rate of structural build-up at rest can be ensured by incorporating a greater volume of coarse aggregate, lower paste volume, and/or lower sand-to-total aggregate ratio. Incorporating coarse aggregate of larger maximum size could also increase the thixotropy and hence reduce the lateral pressure. This can also be achieved by reducing the workability of SCC using less HRWRA concentration. Indeed, all mixture factors have been replaced by measuring the rate of structural build-up at rest (or thixotropy) using the developed portable vane and inclined plane field-oriented test as well as the modified Tattersall MK-III concrete rheometer. On the other hand, increasing or maintaining the concrete temperature at a certain level plays an important role to reduce the lateral pressure. The higher concrete temperature can accelerate the heat of hydration of cement with water and increase the internal friction leading to higher thixotropy. Controlling the placement rate has a great impact on the resultant lateral pressure of SCC. The lateral pressure can be reduced by slowing down the casting rate, as concrete has more time to build-up. However, this can slow down the rate of construction. The casting rate should be optimized to yield a cost effective formwork system. Pausing the continuous casting by a waiting period can reduce the exerted lateral pressure. The research investigation could accelerate the acceptance and implementation of SCC technology in cast-in-place applications, which is the preponderate business of the ready mixed concrete suppliers. The research findings could also contribute to the removal of some of the major barriers hindering the acceptance of SCC in cast-in-place applications and provide the industry with much needed guidelines on formwork pressure. (Abstract shortened by UMI.)
Shadid, Husam; Keckeisen, Maureen; Zarrinpar, Ali
2017-10-01
Although enteral feeding in critically ill patients has been shown to be beneficial, reliable postpyloric placement of feeding tubes remains a challenge. The standard of care involves blind placement, frequently requiring multiple attempts, and radiographs. To evaluate the effect of electromagnetic-guided bedside placement in reducing time to establishment of feeding, lung placement, use of radiography, and cost, we initiated a prospective trial using electromagnetic-guided bedside placement and compared them to a retrospective cohort. Fifty-three consecutive placements of nasoenteral feeding tubes were made using electromagnetic-guidance on patients requiring enteral nutrition in a surgical intensive care unit at a tertiary care center. Sixty-three placement attempts in the preceding seven months served as controls. There were no significant differences between the two groups in terms of age, sex, weight, body mass index, hiatal or ventral hernias, or previous esophageal/gastric operations. The number of radiographs needed per patient, need for fluoroscopy, radiology charge per patient for the tube placement, and time from first attempt at placement to confirmation of postpyloric location were lower for the electromagnetic-guided group. Use of electromagnetic guidance allows reliable and cost-effective postpyloric enteral feeding tube placement compared with blind insertion.
The lateral mesodermal divide: an epigenetic model of the origin of paired fins.
Nuño de la Rosa, Laura; Müller, Gerd B; Metscher, Brian D
2014-01-01
By examining development at the level of tissues and processes, rather than focusing on gene expression, we have formulated a general hypothesis to explain the dorso-ventral and anterior-posterior placement of paired appendage initiation sites in vertebrates. According to our model, the number and position of paired appendages are due to a commonality of embryonic tissue environments determined by the global interactions involving the two separated layers (somatic and visceral) of lateral plate mesoderm along the dorso-ventral and anterior-posterior axes of the embryo. We identify this distribution of developmental conditions, as modulated by the separation/contact of the two LPM layers and their interactions with somitic mesoderm, ectoderm, and endoderm as a dynamic developmental entity which we have termed the lateral mesodermal divide (LMD). Where the divide results in a certain tissue environment, fin bud initiation can occur. According to our hypothesis, the influence of the developing gut suppresses limb initiation along the midgut region and the ventral body wall owing to an "endodermal predominance." From an evolutionary perspective, the lack of gut regionalization in agnathans reflects the ancestral absence of these conditions, and the elaboration of the gut together with the concomitant changes to the LMD in the gnathostomes could have led to the origin of paired fins. © 2013 Wiley Periodicals, Inc.
Pini, Núbia Inocencya Pavesi; Marchi, Luciana Manzotti De; Pascotto, Renata Corrêa
2015-01-01
Maxillary lateral incisor agenesis (MLIA) is a condition that affects both dental esthetics and function in young patients, and represents an important challenge for clinicians. Although several treatment options are available, the mesial repositioning of the canines followed by teeth recontouring into lateral incisors; or space opening/maintenance followed by implant placement have recently emerged as two important treatment approaches. In this article, the current and latest literature has been reviewed in order to summarize the functional and esthetic outcomes obtained with these two forms of treatment of MLIA patients in recent years. Indications, clinical limitations and the most important parameters to achieve the best possible results with each treatment modality are also discussed. Within the limitations of this review, it is not possible to assert at this point in time that one treatment approach is more advantageous than the other. Long-term followup studies comparing the existing treatment options are still lacking in the literature, and they are necessary to shed some light on the issue. It is possible, however, to state that adequate multidisciplinary diagnosis and planning are imperative to define the treatment option that will provide the best individual results for patients with MLIA. PMID:25646137
Low-Dose Radiation 3D Intraoperative Imaging: How Low Can We Go? An O-Arm, CT Scan, Cadaveric Study.
Sarwahi, Vishal; Payares, Monica; Wendolowski, Stephen; Maguire, Kathleen; Thornhill, Beverly; Lo, Yungtai; Amaral, Terry D
2017-11-15
MINI: The objective of this study was to evaluate the accuracy and reliability of pedicle screw placement using O-Arm at dosages below the manufactured recommended dose. O-Arm at reduced dose showed a 90% accuracy when compared with computed tomography; however, about 30% medial breaches were misclassified. Cadaveric study. The objective was to evaluate O-Arm's ability at low-dose (LD) settings to assess intraoperative screw placement. Accurate placement of pedicle screws is crucial because of proximity to vital structures. Malposition of screws may result in significant morbidity and potential mortality. O-arm provides real-time, intraoperative imaging of patient's anatomy and provides higher accuracy in scoliosis surgeries, avoiding risk to vital structures. We hypothesize using LD or ultra-low doses (ULDs) to obtain intraoperative images allow for accurate assessment of screw placement, both minimizing radiation exposure and preventing screw misplacement. Eight cadavers were instrumented with pedicle screws bilaterally from T1 to S1. Screws were randomly placed using O-arm navigation into three positions: contained within the bone, OUT-anterior/lateral, and OUT-medial. O-arm images were obtained at three dosage settings: LD (kVp120/mAs125-lowest manufacturer recommended), very-low dose (VLD) (kVp120/mAs63), and ULD (kVp120/mAs39). Computed tomography (CT) scan was performed using institution's LD protocol (kVp100/mAs50) and gross dissection to identify screw positions. LD, VLD, ULD, and CT for identifying "IN" screws relative to gross dissection had, a mean (standard deviation) sensitivity of 84.2% (±5.7), specificity of 76.1% (±9.3), and accuracy of 79.9% (±3.1) from all three observers. Across the three observers, the interobserver agreement was 0.67 (0.61-0.72) for LD, 0.74 (0.69-0.79) for VLD, 0.61 (0.56-0.66) for ULD, and 0.79 (0.74-0.84) for CT. Effective doses of radiation (mSV) for LD O-arm scan was 2.16, VLD 1.08, ULD 0.68, and our LD CT protocol was 1.05. Accuracy of pedicle screw placement is similar for O-arm at all doses and CT compared to gross dissection. Interobserver reliability was substantial for VLD and CT. Approximately 30% of medial screw breaches are, however, misclassified. ULD and VLDs can be used for intraoperative navigation and evaluation purposes within these limitations. N/A.
Pathak, Hemant R.; Jain, Tarunkumar Prakash; Bhujbal, Sachin A.; Meshram, Kunal R.; Gadekar, Chetan; Parab, Sandesh
2017-01-01
Objective To compare long- term outcomes of buccal mucosa graft (BMG) augmentation urethroplasty for long segment bulbar urethral strictures done by placing the graft ventrally, dorso-laterally and dorsally. Material and methods We conducted a single institution retrospective study on 112 who underwent BMG augmentation urethroplasty for non-traumatic bulbar urethral strictures between January 2005 to December 2014. The cases were divided into three groups based on the site of placement of BMG graft i.e. (a) Ventral (n=44), (b) Dorso-lateral (n=48) and (c) Dorsal (n=20). Follow-up period was from one year to five years. Patients with failed outcomes underwent urethroscopy or retrograde urethrogram to note the site of recurrence of stricture. Results Out of 112 cases 91 (81%) were successful and 21 (19%) failed. The success rates for ventral, dorso-lateral and dorsal BMG augmentation procedures were 89%, 79% and 70%, respectively (p=0.18). Among 21 failed cases, 12 cases (57%) had stricture at proximal anastomotic site, 4 cases (19%) at graft and 5 cases (24%) at distal anastomotic site (p=0.01). Conclusion The overall success rate for BMG augmentation urethroplasty is equal for all techniques. Ventral onlay urethroplasty provides better exposure of proximal anastomotic site thus it is associated with minimum proximal anastomotic site recurrence rates. Patients with extensive spongiofibrosis and long segment strictures had higher rates of failure. PMID:28861310
Pathak, Hemant R; Jain, Tarunkumar Prakash; Bhujbal, Sachin A; Meshram, Kunal R; Gadekar, Chetan; Parab, Sandesh
2017-09-01
To compare long- term outcomes of buccal mucosa graft (BMG) augmentation urethroplasty for long segment bulbar urethral strictures done by placing the graft ventrally, dorso-laterally and dorsally. We conducted a single institution retrospective study on 112 who underwent BMG augmentation urethroplasty for non-traumatic bulbar urethral strictures between January 2005 to December 2014. The cases were divided into three groups based on the site of placement of BMG graft i.e. (a) Ventral (n=44), (b) Dorso-lateral (n=48) and (c) Dorsal (n=20). Follow-up period was from one year to five years. Patients with failed outcomes underwent urethroscopy or retrograde urethrogram to note the site of recurrence of stricture. Out of 112 cases 91 (81%) were successful and 21 (19%) failed. The success rates for ventral, dorso-lateral and dorsal BMG augmentation procedures were 89%, 79% and 70%, respectively (p=0.18). Among 21 failed cases, 12 cases (57%) had stricture at proximal anastomotic site, 4 cases (19%) at graft and 5 cases (24%) at distal anastomotic site (p=0.01). The overall success rate for BMG augmentation urethroplasty is equal for all techniques. Ventral onlay urethroplasty provides better exposure of proximal anastomotic site thus it is associated with minimum proximal anastomotic site recurrence rates. Patients with extensive spongiofibrosis and long segment strictures had higher rates of failure.
Use of laterally placed vacuum drains for management of aural hematomas in five dogs.
Pavletic, Michael M
2015-01-01
5 dogs (a Newfoundland, Golden Retriever, Shiba Inu, Staffordshire Terrier, and Vizsla) were referred for evaluation and treatment of unilateral aural hematomas within a week after their formation. Aural hematomas involved the left (3) or right (2) ears. With patients under anesthesia, the aural hematomas were approached surgically from the convex, or lateral, pinnal surface. Two small incisions were used to position a vacuum drain into the incised hematoma cavity. The drain exited at the base of the pinna and adjacent cervical skin. The free end of the drain was attached to a vacuum reservoir for 18 to 21 days. Drains and skin sutures were removed at this time along with the protective Elizabethan collar. All hematomas resolved and surgical sites healed during the minimum 6-month follow-up period. Cosmetic results were considered excellent in 4 of 5 patients. Slight wrinkling of the pinna in 1 patient resulted from asymmetric enlargement of the cartilaginous walls of the hematoma, where vacuum application resulted in a slight folding of the redundant lateral cartilage wall. The described treatment was efficient, economical, and minimally invasive and required no bandaging or wound care. Placement of the drain tubing on the convex (lateral) aspect sheltered the system from displacement by patients with an Elizabethan collar in place. Overall cosmetic results were excellent; asymmetric enlargement of the cartilaginous walls of the hematoma with slight folding of the pinna was seen in 1 patient.
NASA Astrophysics Data System (ADS)
Crouch, Stephen; Kaylor, Brant M.; Barber, Zeb W.; Reibel, Randy R.
2015-09-01
Currently large volume, high accuracy three-dimensional (3D) metrology is dominated by laser trackers, which typically utilize a laser scanner and cooperative reflector to estimate points on a given surface. The dependency upon the placement of cooperative targets dramatically inhibits the speed at which metrology can be conducted. To increase speed, laser scanners or structured illumination systems can be used directly on the surface of interest. Both approaches are restricted in their axial and lateral resolution at longer stand-off distances due to the diffraction limit of the optics used. Holographic aperture ladar (HAL) and synthetic aperture ladar (SAL) can enhance the lateral resolution of an imaging system by synthesizing much larger apertures by digitally combining measurements from multiple smaller apertures. Both of these approaches only produce two-dimensional imagery and are therefore not suitable for large volume 3D metrology. We combined the SAL and HAL approaches to create a swept frequency digital holographic 3D imaging system that provides rapid measurement speed for surface coverage with unprecedented axial and lateral resolution at longer standoff ranges. The technique yields a "data cube" of Fourier domain data, which can be processed with a 3D Fourier transform to reveal a 3D estimate of the surface. In this paper, we provide the theoretical background for the technique and show experimental results based on an ultra-wideband frequency modulated continuous wave (FMCW) chirped heterodyne ranging system showing ~100 micron lateral and axial precisions at >2 m standoff distances.
An FPGA Noise Resistant Digital Temperature Sensor with Auto Calibration
2012-03-01
temperature sensor [6] . . . . . . . . . . . . . . 14 9 Two different digital temperature sensor placement algorithms: (a) Grid placement (b) Optimal...create a grid over the FPGA. While this method works reasonably well, it requires many sensors, some of which are unnecessary. The optimal placement, on...temperature sensor placement algorithms: (a) Grid placement (b) Optimal Placement [7] 16 2.4 Summary Integrated circuits’ sensitivity to temperatures has
Placement education pedagogy as social participation: what are students really learning?
Kell, Clare
2014-03-01
This paper draws on empirical fieldwork data of naturally occurring UK physiotherapy placement education to make visible how education is actually carried out and suggest what students may be learning through their placement interactions. The data challenge everyone involved in placement education design and practice to consider the values and practices students are learning to perpetuate through placement education experiences. The researcher undertook an ethnomethodologically informed ethnographic observation of naturally occurring physiotherapy placement education in two UK NHS placement sites. This study adopted a social perspective of learning to focus on the minutiae of placement educator, student and patient interaction practices during student-present therapeutic activities. Two days of placement for each of six senior students were densely recorded in real-time focussing specifically on the verbal, kinesics and proxemics-based elements of the participants' interaction practices. Repeated cycles of data analysis suggested consistent practices irrespective of the placement, educators, students or patients. The data suggest that placement education is a powerful situated learning environment in which students see, experience and learn to reproduce the physiotherapy practices valued by the local placement. Consistently, placement educators and students co-produced patient-facing activities as spectacles of physiotherapy-as-science. In each setting, patients were used as person-absent audiovisual teaching aids from which students learnt to make a case for physiotherapy intervention. The paper challenges physiotherapists and other professions using work-placement education to look behind the rhetoric of their placement documentation and explore the reality of students' learning in the field. The UK-based physiotherapy profession may wish to consider further the possible implications of its self-definition as a 'science-based healthcare profession' on its in-the-presence-of-students interactions with patients. Copyright © 2013 John Wiley & Sons, Ltd.
Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu
2018-05-01
To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.
History of surgery for atrial fibrillation.
Edgerton, Zachary J; Edgerton, James R
2009-12-01
There is a rich history of surgery for atrial fibrillation. Initial procedures were aimed at controlling the ventricular response rate. Later procedures were directed at converting atrial fibrillation to normal sinus rhythm. These culminated in the Cox Maze III procedure. While highly effective, the complexity and morbidity of the cut and sew Maze III limited its adoption. Enabling technology has developed alternate energy sources designed to produce a transmural atrial scar without cutting and sewing. Termed the Maze IV, this lessened the morbidity of the procedure and widened the applicability. Further advances in minimal access techniques are now being developed to allow totally thorascopic placement of all the left atrial lesions on the full, beating heart, using alternate energy sources.
Use of the S3 Corridor for Iliosacral Fixation in a Dysmorphic Sacrum: A Case Report.
El Dafrawy, Mostafa H; Strike, Sophia A; Osgood, Greg M
2017-01-01
The S1 and S2 corridors are the typical osseous pathways for iliosacral screw fixation of posterior pelvic ring fractures. In dysmorphic sacra, the S1 screw trajectory is often different from that in normal sacra. We present a case of iliosacral screw placement in the third sacral segment for fixation of a complex lateral compression type-3 pelvic fracture in a patient with a dysmorphic sacrum. In patients with dysmorphic sacra and unstable posterior pelvic ring fractures or dislocations, the S3 corridor may be a feasible osseous fixation pathway that can be used in a manner equivalent to the S2 corridor in a normal sacrum.
Biagetti, Carlo; Nicola, Monica; Borderi, Marco; Pavoni, Michele; Tampellini, Livia; Verucchi, Gabriella; Chiodo, Francesco
2009-04-01
Immune reconstitution inflammatory syndrome (IRIS) in HIV-1-infected patients is associated with an exaggerated inflammatory response against an opportunistic infection during highly active antiretroviral therapy. The only review on IRIS associated with Criptococcus neoformans reported 21 episodes including lymphadenitis, necrotizing pneumonitis, breast and cutaneous abscess, and cryptococcomas. To our knowledge this is the first report of IRIS associated with previous meningeal criptococcal infection which required neurosurgical intervention with placement of a ventriculo-peritoneal shunt to drain a CSF cyst formed by exclusion of the temporal horn of the right lateral ventricle. We demonstrate that this procedure is possible without complications such as cryptococcal dissemination into the peritoneum.
Khan, Rabia; Oakes, Peter; Tubbs, R Shane; Oakes, W Jerry
2017-01-01
Chiari I malformation can be due to a multitude of etiologies such as craniosynostosis or hydrocephalus. A posterior fossa extra-axial cyst (PFEAC) appears to be an extremely rare cause of this form of hindbrain herniation. Herein, we report a case of PFEAC that presented with no Chiari I malformation and then presented months later with a significant Chiari I malformation. Following shunt placement of a PFEAC, striking reversal of the Chiari malformation as well as reconstitution of the cerebellum was noted. Patients with PFEAC might develop a Chiari I malformation and this might be treated with shunting of the PFEAC alone.
NASA Astrophysics Data System (ADS)
Lin, Zhe; Zhu, Linhang; Cui, Baoling; Li, Yi; Ruan, Xiaodong
2014-12-01
Gate valve has various placements in the practical usages. Due to the effect of gravity, particle trajectories and erosions are distinct between placements. Thus in this study, gas-solid flow properties and erosion in gate valve for horizontal placement and vertical placement are discussed and compared by using Euler-Lagrange simulation method. The structure of a gate valve and a simplified structure are investigated. The simulation procedure is validated in our published paper by comparing with the experiment data of a pipe and an elbow. The results show that for all investigated open degrees and Stokes numbers (St), there are little difference of gas flow properties and flow coefficients between two placements. It is also found that the trajectories of particles for two placements are mostly identical when St « 1, making the erosion independent of placement. With the increase of St, the distinction of trajectories between placements becomes more obvious, leading to an increasing difference of the erosion distributions. Besides, the total erosion ratio of surface T for horizontal placement is two orders of magnitudes larger than that for vertical placement when the particle diameter is 250μm.
Charlton-Ouw, Kristofer M; Leake, Samuel S; Sola, Cristina N; Sandhu, Harleen K; Albarado, Rondel; Holcomb, John B; Miller, Charles C; Safi, Hazim J; Azizzadeh, Ali
2015-01-01
Considering new guidelines for retrievable inferior vena cava filters (IVCFs), we examine our initial experience after establishing a comprehensive filter removal program in our level 1 trauma center. We evaluated the technical and financial feasibility of this program and barriers to IVCF retrieval, including insurance status and costs, in trauma patients. Trauma patients receiving IVCFs from May 2011 to 2013 were consented and prospectively enrolled in the study program. Retrieval rates were assessed for the years before study initiation. Primary outcome was IVCF retrieval. Hospital financial data for retrieval were examined and univariate analysis performed. Hospital cost-to-charge and payment-to-charge ratios were assessed. Before study initiation from April 2009 to 2011, 66 IVCFs were placed in trauma patients with only 2 retrievals in 2 years. During the study period, 247 trauma patients had IVCF placement of which 111 (45%) were enrolled. The main reason for nonenrollment was lack of referral by the implanting team. Retrieval was attempted in 100 outpatients with success in 85 (85%). Patients enrolled in the program were more likely to have their filters removed (73% vs. 18%; odds ratio, 12.6; 95% confidence interval, 6.6-24.3; P < 0.001). Mean time from placement to attempt was 6.2 ± 4.0 months (range, 0.5-31.8). Of the total attempts, 29% were nonresource patients, 11% had Medicaid, and 60% had commercial insurance including Medicare patients. Chances of successful retrieval were higher if performed later during the study (P = 0.03). Successful retrieval was not related to insurance status (P = not significant). The mean total hospital charges related to retrieval were $4,493 (range, $2,510-$9,106). Successful retrieval contributed to lower total charges (P < 0.01). Factors contributing to higher total charges were retrieval attempt later in study period (P = 0.01) and commercial insurance status (P = 0.04). The rate of IVCF placement in trauma patients increased 4-fold over 4 years. The rate of IVCF retrieval increased more than 14-fold during the same period after establishment of the retrieval program. Elective outpatient retrieval of IVCFs in all eligible trauma patients is financially feasible without loss to the health care system even in regions with high rates of uninsured. A major barrier to successful filter retrieval was lack of patient referral into the program by implanting physicians. Hospital administration and physician outreach are important determinants of successful IVCF retrieval in trauma patients. Published by Elsevier Inc.
Parametric Study of a Mixer/Ejector Nozzle with Mixing Enhancement Devices
NASA Technical Reports Server (NTRS)
DalBello, T.; Steffen, C. J., Jr.
2001-01-01
A numerical study employing a simplified model of the High Speed Civil Transport mixer/ejector nozzle has been conducted to investigate the effect of tabs (vortex generators) on the mixing process. More complete mixing of the primary and secondary flows within the confined ejector lowers peak exit velocity resulting in reduced jet noise. Tabs were modeled as vortex pairs and inserted into the computational model. The location, size, and number of tabs were varied and its effect on the mixing process is presented here both quantitatively and qualitatively. A baseline case (no tabs) along with six other cases involving two different vortex strengths at three different orientations have been computed and analyzed. The case with the highest vorticity (six vortices representing large tabs) gives the best mixing. It is shown that the influence of the vorticity acts primarily in the forward or middle portions of the duct, significantly alters the flow structure, and promotes some mixing in the lateral direction. Unmixed pockets were found at the top and bottom of the lobe, and more clever placement of tabs improved mixing in the vertical direction. The technique of replacing tabs with vortices shows promise as an efficient tool for quickly optimizing tab placement in lobed mixers.
Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng
2015-01-01
Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.
West, A E; Jones, M L; Newcombe, R G
1995-11-01
Two arch wires commonly used for initial tooth alignment were compared with regard to their clinical effectiveness. The two arch wires tested were 0.0155-inch diameter multiple-stranded stainless steel wire (Dentaflex, Dentaurium, Optident, Yorkshire, England) and 0.014-inch diameter nickel-titanium alloy wire (NiTi, ORMCO Co., Monrovia, Calif.). Consecutive patients attending an orthodontic clinic for routine placement of a fixed appliance were randomly assigned one of these two initial arch wires. Good quality alginate impressions of the appropriate dental arch were taken before arch wire placement and also at the subsequent appointment, which was, on average, 6 weeks later. Seventy-four arches were used in this study. The degree of tooth alignment achieved for each wire type was compared with a Reflex Microscope (Reflex Measurement Ltd., Butleigh, England) to make detailed measurements on the resultant casts. The degree of initial alignment achieved with the two wires was similar over this 6-week period. However, some differences were found for the lower labial segment where the interbracket span is usually reduced and where the superelastic nickel-titanium wire was found to give improved alignment. No threshold of crowding was found where one arch wire performed better than the other.
Comparison of two kinds of bovine bone in maxillary sinus augmentation: a histomorphometric study.
Moon, Jee-Won; Sohn, Dong-Seok; Heo, Jeung-Uk; Kim, Jin Sun
2015-02-01
The purpose of this study was to compare the histomorphometric from sinus augmentation with calcium-phosphate nanocrystal-coated bovine bone (Biocera) and anorganic bovine bone matrix (Bio-Oss). Bilateral maxillary sinus augmentations were performed on 5 patients with delayed placement of implants. The lateral bony window was created using a piezoelectric saw, and the sinus membrane was elevated to make a new compartment. Bio-Oss was grafted in one sinus as the control group and Biocera was grafted in the opposite sinus as the test group. The bony window was repositioned over the bone graft. In all cases, samples were taken for biopsy at the time of implant placement, 6 to 8 months after the grafting procedure. Independent t tests were used to examine between-group differences. None of the 5 patients had complications during healing period. Histomorphometrically, the Bio-Oss group showed 28.46% (±5.28%) of newly formed bone. Biocera group showed 29.94% (±8.72%) of newly formed bone. Newly formed bone along inner surface of repositioned bony window area showed more mature and dense bone structure than new bone formed along bone graft. This study revealed that both bovine bone grafts were considered as suitable bone graft materials for maxillary sinus augmentation.
Optimal sensor placement for time-domain identification using a wavelet-based genetic algorithm
NASA Astrophysics Data System (ADS)
Mahdavi, Seyed Hossein; Razak, Hashim Abdul
2016-06-01
This paper presents a wavelet-based genetic algorithm strategy for optimal sensor placement (OSP) effective for time-domain structural identification. Initially, the GA-based fitness evaluation is significantly improved by using adaptive wavelet functions. Later, a multi-species decimal GA coding system is modified to be suitable for an efficient search around the local optima. In this regard, a local operation of mutation is introduced in addition with regeneration and reintroduction operators. It is concluded that different characteristics of applied force influence the features of structural responses, and therefore the accuracy of time-domain structural identification is directly affected. Thus, the reliable OSP strategy prior to the time-domain identification will be achieved by those methods dealing with minimizing the distance of simulated responses for the entire system and condensed system considering the force effects. The numerical and experimental verification on the effectiveness of the proposed strategy demonstrates the considerably high computational performance of the proposed OSP strategy, in terms of computational cost and the accuracy of identification. It is deduced that the robustness of the proposed OSP algorithm lies in the precise and fast fitness evaluation at larger sampling rates which result in the optimum evaluation of the GA-based exploration and exploitation phases towards the global optimum solution.
Bot, Maarten; van den Munckhof, Pepijn; Bakay, Roy; Stebbins, Glenn; Verhagen Metman, Leo
2017-01-01
Objective To determine the accuracy of intraoperative computed tomography (iCT) in localizing deep brain stimulation (DBS) electrodes by comparing this modality with postoperative magnetic resonance imaging (MRI). Background Optimal lead placement is a critical factor for the outcome of DBS procedures and preferably confirmed during surgery. iCT offers 3-dimensional verification of both microelectrode and lead location during DBS surgery. However, accurate electrode representation on iCT has not been extensively studied. Methods DBS surgery was performed using the Leksell stereotactic G frame. Stereotactic coordinates of 52 DBS leads were determined on both iCT and postoperative MRI and compared with intended final target coordinates. The resulting absolute differences in X (medial-lateral), Y (anterior-posterior), and Z (dorsal-ventral) coordinates (ΔX, ΔY, and ΔZ) for both modalities were then used to calculate the euclidean distance. Results Euclidean distances were 2.7 ± 1.1 and 2.5 ± 1.2 mm for MRI and iCT, respectively (p = 0.2). Conclusion Postoperative MRI and iCT show equivalent DBS lead representation. Intraoperative localization of both microelectrode and DBS lead in stereotactic space enables direct adjustments. Verification of lead placement with postoperative MRI, considered to be the gold standard, is unnecessary. PMID:28601874
Bot, Maarten; van den Munckhof, Pepijn; Bakay, Roy; Stebbins, Glenn; Verhagen Metman, Leo
2017-01-01
To determine the accuracy of intraoperative computed tomography (iCT) in localizing deep brain stimulation (DBS) electrodes by comparing this modality with postoperative magnetic resonance imaging (MRI). Optimal lead placement is a critical factor for the outcome of DBS procedures and preferably confirmed during surgery. iCT offers 3-dimensional verification of both microelectrode and lead location during DBS surgery. However, accurate electrode representation on iCT has not been extensively studied. DBS surgery was performed using the Leksell stereotactic G frame. Stereotactic coordinates of 52 DBS leads were determined on both iCT and postoperative MRI and compared with intended final target coordinates. The resulting absolute differences in X (medial-lateral), Y (anterior-posterior), and Z (dorsal-ventral) coordinates (ΔX, ΔY, and ΔZ) for both modalities were then used to calculate the euclidean distance. Euclidean distances were 2.7 ± 1.1 and 2.5 ± 1.2 mm for MRI and iCT, respectively (p = 0.2). Postoperative MRI and iCT show equivalent DBS lead representation. Intraoperative localization of both microelectrode and DBS lead in stereotactic space enables direct adjustments. Verification of lead placement with postoperative MRI, considered to be the gold standard, is unnecessary. © 2017 The Author(s) Published by S. Karger AG, Basel.
Growth recovery in newly arrived international adoptees in Italy: relation to parenting stress.
Canzi, Elena; Rosnati, Rosa; Miller, Laurie C
2018-04-12
Following initial adversities, most internationally adopted children arrive with significant growth delays. Post-placement recovery has been widely documented, but research about risk or protective factors is still limited. Even less is known about the relationship between growth recovery and the quality of the family environment. 28 children in 26 adoptive families were involved in this longitudinal study. A comprehensive evaluation (including anthropometry, cognitive assessment [using the Leiter International Performance Scale-Revised], and completion by both parents of the Parenting Stress Index - Short Form) was done at arrival of the child, and 1 year later. Results evidenced that on arrival nearly half of children had growth measurements in the normal range. All the children showed a significant recovery in height and weight at 6 and 12 months post-placement. Initial and follow up growth measurements correlated strongly. Growth recovery was related to the age of the child at adoption, the proportion of time the child had resided in institutional care, as well as parenting stress. Results suggested that the higher the parenting stress experienced the less improvements occurred in children: for mothers for height and weight, for fathers for all the growth indicators. Results suggested the critical importance of family factor in influencing children's growth recovery.
Wu, Min-Kai; de Groot, Sjoerd D; van der Sluis, Luc W M; Wesselink, Paul R
2003-09-01
We sought to measure and calculate the percentage of the gutta-percha-filled area in the apical root canal after the use of a standardized or inverted master cone in cold lateral compaction.Study design Two groups of extracted mandibular premolars with a single canal were instrumented with instruments of the same size; furthermore, they were obturated with laterally compacted gutta-percha cones with AH26 used as a sealer. In the first group, a standardized master cone was used with its narrow end in an apical position, whereas in the other group, an inverted master cone was used with its wide end in an apical position. The 2 master cones had the same apical diameter and fit in the apical canal. After lateral compaction, horizontal sections were cut at a level 3 and 5 mm from the apex of each filled tooth. Photographs of the sections were taken by using a microscope equipped with a digital camera; the photos were then scanned as tagged-image file format images. The cross-sectional area of the canal and the gutta-percha were measured by using an image-analysis program. The percentage of gutta-percha-filled area was calculated. At both levels, the inverted master cone produced a significantly higher percentage, statistically, of gutta-percha-filled area than did the standardized master cone (P =.001 at 3 mm; P =.012 at 5 mm). The use of an inverted master cone in cold lateral compaction may facilitate the apical placement of accessory cones, significantly increasing the volume of gutta-percha while reducing the volume of sealer in the apical root canal.
Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L
2002-01-01
To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.
25 CFR 26.4 - Who administers the Job Placement and Training Program?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Who administers the Job Placement and Training Program... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training Program? The Job Placement and Training Program is administered by the Bureau of Indian Affairs or a...
The Placement Handbook. A Guide for the Competitive Employment of the Handicapped.
ERIC Educational Resources Information Center
Horn, Adelaide; Drury, Stephen
This handbook stresses those components that are considered peripheral to the placement process but that must precede the actual placement. The philosophy of placement upon which this guide is based appears first. Discussions follow of the basic components of the process of training and placement of handicapped individuals, including a varied…
Standard Transistor Array (STAR). Volume 1: Placement technique
NASA Technical Reports Server (NTRS)
Cox, G. W.; Caroll, B. D.
1979-01-01
A large scale integration (LSI) technology, the standard transistor array uses a prefabricated understructure of transistors and a comprehensive library of digital logic cells to allow efficient fabrication of semicustom digital LSI circuits. The cell placement technique for this technology involves formation of a one dimensional cell layout and "folding" of the one dimensional placement onto the chip. It was found that, by use of various folding methods, high quality chip layouts can be achieved. Methods developed to measure of the "goodness" of the generated placements include efficient means for estimating channel usage requirements and for via counting. The placement and rating techniques were incorporated into a placement program (CAPSTAR). By means of repetitive use of the folding methods and simple placement improvement strategies, this program provides near optimum placements in a reasonable amount of time. The program was tested on several typical LSI circuits to provide performance comparisons both with respect to input parameters and with respect to the performance of other placement techniques. The results of this testing indicate that near optimum placements can be achieved by use of the procedures incurring severe time penalties.
Hartshorn, Timothy; Otarodifard, Karimdad; White, Eric A; Hatch, George F Rick
2013-11-01
Little has been written about the use of radiographic landmarks for locating the origin of the superficial medial collateral ligament (sMCL). A standardized radiographic landmark for the sMCL origin using intraoperative fluoroscopic imaging may be of value in aiding the surgeon in accurate femoral tunnel placement in the setting of extensive soft tissue disruption and bony attrition. To determine a reproducible radiographic landmark that will assist in correct femoral tunnel placement in sMCL repair and reconstruction. Descriptive laboratory study. Ten fresh-frozen unmatched human cadaveric knees were dissected, and the origin of the sMCL was exposed. A 2-mm metallic marker was then placed at the center of the femoral origin of the sMCL. True lateral fluoroscopically assisted digital radiographs were obtained of the knee with the posterior and distal femoral condyles overlapping in a standardized fashion. With the use of computer software, reference lines were drawn on the images, creating 4 quadrants. Two independent examiners performed quantitative measurements of the sMCL origin in relation to this axis and to the Blumensaat line. Mean measurements showed the sMCL origin to be closely related to the intersection point of the Blumensaat line and a line drawn distally from the posterior femoral cortex on a true lateral radiograph. The sMCL origin was found at a mean point 1.6 ± 4.3 mm posterior and 4.9 ± 2.1 mm proximal to the intersection of a line paralleling the posterior femoral cortex and a line drawn perpendicular to the posterior femoral cortical line, where it intersects the Blumensaat line. In 5 of 10 specimens, the center of the sMCL origin fell precisely on the Blumensaat line. The remaining specimens had sMCL origins anterior to the Blumensaat line. The femoral origin of the sMCL was found in the proximal and posterior quadrants in 8 of 10 specimens. With a relatively small amount of deviation, the sMCL origin can be consistently identified on a true lateral radiograph of the knee using reproducible reference lines on fluoroscopic imaging. Accurate identification of the femoral origin of the sMCL can be accomplished by intraoperative fluoroscopic imaging. This information may be of significant benefit in repairing acute injuries and in reconstructive procedures complicated by bony attrition and soft tissue loss.
Merli, Mauro; Moscatelli, Marco; Mariotti, Giorgia; Rotundo, Roberto; Nieri, Michele
2013-01-01
To compare 100% deproteinised bovine bone matrix (DBBM) grafts (test group) with 100% autogenous bone (AB) grafts (control group) for lateral maxillary sinus floor elevation in a parallel group, superiority, randomised controlled trial. Patients with 1 to 3 mm of residual bone height below the maxillary sinus were randomised for sinus floor elevation with DBBM and AB grafts and simultaneous implant placement. Randomisation was computer generated with allocation concealment by sealed envelopes and the radiographic examiner was blinded to group assignment. The abutment connection was performed 8 months after surgery and insertion of the provisional prostheses was performed 9 months after surgery. Outcome variables were implant failures, prosthetic failures, complications, chair time, postoperative pain and radiographic bone level 6 months after loading. Forty patients were randomised: 20 (32 implants) to the DBBM group and 20 (27 implants) to the AB group. One patient from the AB group dropped out. Two implant failures occurred in the DBBM group and no implant failure occurred in the AB group (P = 0.4872). All of the planned prostheses could be delivered. One complication occurred in the DBBM group and 2 in the AB group (P = 0.6050). Chair time was shorter for the DBBM group, with a difference of 27.3 minutes (P = 0.0428). Pain difference measured with a visual analogue scale for 6 days post-surgery was 0.2 in favour of the DBBM group (P = 0.6838). The difference in vertical bone height was 0.0 mm (95% CI -1.1, 1.1; P = 0.9703) and the difference in marginal bone level was 0.3 in favour of AB (95% CI -0.3, 0.9; P = 0.3220). No differences apart from chair time were observed when comparing DBBM and AB grafts with simultaneous implant placement in sinus elevation.
Leiter, Jeff R S; de Korompay, Nevin; Macdonald, Lindsey; McRae, Sheila; Froese, Warren; Macdonald, Peter B
2011-08-01
To compare the reliability of tibial tunnel position and angle produced with a standard ACL guide (two-dimensional guide) or Howell 65° Guide (three-dimensional guide) in the coronal and sagittal planes. In the sagittal plane, the dependent variables were the angle of the tibial tunnel relative to the tibial plateau and the position of the tibial tunnel with respect to the most posterior aspect of the tibia. In the coronal plane, the dependent variables were the angle of the tunnel with respect to the medial joint line of the tibia and the medial and lateral placement of the tibial tunnel relative to the most medial aspect of the tibia. The position and angle of the tibial tunnel in the coronal and sagittal planes were determined from anteroposterior and lateral radiographs, respectively, taken 2-6 months postoperatively. The two-dimensional and three-dimensional guide groups included 28 and 24 sets of radiographs, respectively. Tibial tunnel position was identified, and tunnel angle measurements were completed. Multiple investigators measured the position and angle of the tunnel 3 times, at least 7 days apart. The angle of the tibial tunnel in the coronal plane using a two-dimensional guide (61.3 ± 4.8°) was more horizontal (P < 0.05) than tunnels drilled with a three-dimensional guide (64.7 ± 6.2°). The position of the tibial tunnel in the sagittal plane was more anterior (P < 0.05) in the two-dimensional (41.6 ± 2.5%) guide group compared to the three-dimensional guide group (43.3 ± 2.9%). The Howell Tibial Guide allows for reliable placement of the tibial tunnel in the coronal plane at an angle of 65°. Tibial tunnels were within the anatomical footprint of the ACL with either technique. Future studies should investigate the effects of tibial tunnel angle on knee function and patient quality of life. Case-control retrospective comparative study, Level III.
Sai Kiran, Narayanam Anantha; Kiran Kumar, Veldurti Ananta; Sivaraju, Laxminadh; Kumar, Valluri Anil; Reddy, Chintakunta Rajesh; Agrawal, Amit
2018-06-01
Aberrant medial retropharyngeal prevertebral course of the internal carotid arteries (ICAs) is extremely uncommon. In oropharyngeal surgeries, like transoral odontoidectomy (TOO), this unrecognized aberrant retropharyngeal course of ICAs can result in devastating complications secondary to inadvertent injury of ICAs. We describe this aberrant course of ICAs in a patient with a craniovertebral junction (CVJ) anomaly with a dysmorphic C1 lateral mass on one side and discuss in detail various management issues in this complex case. A 44-year-old patient presented with neck pain, paresthesia in all 4 limbs, and quadriparesis. Computed tomography (CT) of the CVJ revealed os odontoideum, basilar invagination, atlantoaxial dislocation (AAD), severe malalignment of the C1-C2 facets, and an unusually thin (dysmorphic) left C1 lateral mass. Computed tomographic angiography revealed an aberrant medial retropharyngeal course of the bilateral cervical ICAs with near midline location at the level of C1 and C2. Transoral odontoidectomy (TOO) was not considered safe in view of potential injury to medially located ICAs. Normal spinal alignment with reduction of BI and AAD was achieved by C1-C2 joint distraction with placement of a spacer only in the right C1-C2 joint space followed by occipitocervical fusion. The patient experienced complete recovery after surgery with improvement of power in all 4 limbs to 5/5. Identification of this rare aberrant prevertebral course of ICAs in a patient with a CVJ anomaly is critical because it precludes TOO as a treatment option. Correction of BI and AAD is possible even with a unilateral C1-C2 joint spacer when placement of a joint spacer on the other side is not technically feasible. Copyright © 2018 Elsevier Inc. All rights reserved.
Kuchler, Ulrike; Rudelstorfer, Claudia M; Barth, Barbara; Tepper, Gabor; Lidinsky, Dominika; Heimel, Patrick; Watzek, Georg; Gruber, Reinhard
Recombinant human bone morphogenetic protein 2 (rhBMP-2) together with an absorbable collagen carrier (ACS) was approved for augmentation of the maxillary sinus prior to implant placement. The original registration trial was based on a lateral window approach. Clinical outcomes of crestal sinus augmentation with rhBMP-2 have not been reported so far. An uncontrolled pilot trial in which seven patients with a residual maxillary height below 5 mm were enrolled to receive crestal sinus augmentation with rhBMP-2/ACS was conducted. Elevation of the sinus mucosa was performed by gel pressure. Primary endpoints were the gain in augmentation height and volume measured by computed tomography after 6 months. Evaluation of bone quality at the time of implant placement was based on histology. Secondary endpoints were the clinical and radiologic evaluation of the implants and patient satisfaction by visual analog scale (VAS) at the 2-year follow-up. Median gain in augmentation height was 7.2 mm (range 0.0 to 17.5 mm). Five patients gained at least 5 mm of bone height. Two patients with a perforation of the sinus mucosa failed to respond to rhBMP-2/ACS and underwent lateral window augmentation. The median gain in augmentation volume of the five patients was 781.3 mm³ (range 426.9 to 1,242.8 mm³). Biopsy specimens showed a cancellous network consisting of primary plexiform bone with little secondary lamellar bone. After 2 years, implants were in function with no signs of inflammation or peri-implant bone loss. Patients were satisfied with the esthetic outcomes and chewing function. This pilot clinical trial supports the original concept that rhBMP-2/ACS supports bone formation, also in crestal sinus augmentation, and emphasizes the relevance of the integrity of the sinus mucosa to predict the bone gain.
Lateral Meniscal Allograft Transplant via a Medial Approach Leads to Less Extrusion.
Choi, Nam-Hong; Choi, Jeong-Ki; Yang, Bong-Seok; Lee, Doe-Hyun; Victoroff, Brian N
2017-10-01
Accurate positioning of the bony bridge is crucial to prevent extrusion of meniscal allografts after transplant. However, oblique or lateralized placement of the bony bridge of the lateral meniscal allograft may occur due to technical error or a limited visual field. The patellar tendon may be an obstacle to approaching the anterior horn of the lateral meniscus, resulting in a laterally placed allograft. Therefore, lateral meniscal transplant through a medial arthrotomy would be an alternative approach. However, no report exists regarding allograft extrusion when comparing medial and lateral arthrotomy techniques in lateral meniscal transplants. Extrusion of the midbody of the allograft is less severe and the rotation of the bony bridge is less oblique in lateral meniscal allograft transplants through the medial parapatellar approach than those through the lateral approach. Cohort study; Level of evidence, 3. A bony bridge was used to perform 55 lateral meniscal transplants through either a medial or a lateral arthrotomy. Thirty-two allografts were transplanted through a medial arthrotomy and 23 were transplanted through a lateral arthrotomy, not randomly. Because correct positioning of the bony trough through the medial arthrotomy was easier than that through the lateral arthrotomy, the method of the arthrotomy was changed for the latter. The procedure for both groups was identical except for the arthrotomy technique, and rehabilitation was identical for both groups. Follow-up magnetic resonance imaging was conducted for all patients to measure the postoperative extrusion and obliquity of the bony bridge of the allograft. On the coronal view, extrusion was measured as the distance between the outer edge of the articular cartilage of the lateral tibial plateau and the outer edge of the meniscal allograft. On the axial view, a line (line B) was drawn along the longitudinal axis of the bony bridge. The posterior tibial condylar tangential line was drawn between the medial and lateral posterior tibial condylar cortices. A line (line T) was drawn perpendicular to the posterior tibial condylar tangential line. The angle (trough angle) between lines B and T was measured. Postoperative extrusion and the trough angle were compared between the medial and lateral arthrotomy groups. The median extrusion of the midbody of the allograft was 2.2 mm (interquartile range [IQR], 2.4 mm; range, 0-4.6 mm) in the medial arthrotomy group and 3.1 mm (IQR, 1.5 mm; range, 0-5.3 mm) in the lateral arthrotomy group ( P = .001). Seven (21.9%) patients demonstrated extrusion in the medial arthrotomy group, and 15 (65.2%) patients had extrusion in the lateral group ( P = .002). The median trough angle was 0.9° (IQR, 9.3°; range, -8.8-15.8°) in the medial arthrotomy group and 11.6° (IQR, 2.8°; range, 3-19.8°) in the lateral arthrotomy group ( P < .001). Based on this experience, lateral meniscal allograft transplant through a medial arthrotomy is preferred to decrease postoperative extrusion of the allograft.
Clinical and biological analysis in graftless maxillary sinus lift.
Parra, Marcelo; Olate, Sergio; Cantín, Mario
2017-08-01
Maxillary sinus lift for dental implant installation is a well-known and versatile technique; new techniques are presented based on the physiology of intrasinus bone repair. The aim of this review was to determine the status of graftless maxillary sinus lift and analyze its foundations and results. A search was conducted of the literature between 1995 and 2015 in the Medline, ScienceDirect, and SciELO databases using the keywords "maxillary sinus lift," "blood clot," "graftless maxillary sinus augmentation," and "dental implant placement." Ten articles were selected for our analysis of this technique and its results. Despite the limited information, cases that were followed for at least six months and up to four years had a 90% success rate. Published techniques included a lateral window, elevation of the sinus membrane, drilling and dental implant installation, descent of the membrane with variations in the installation of the lateral wall access and suturing. The physiology behind this new bone formation response and the results of the present research were also discussed. We concluded that this is a promising and viable technique under certain inclusion criteria.
Flatfish: an asymmetric perspective on metamorphosis.
Schreiber, Alexander M
2013-01-01
The most asymmetrically shaped and behaviorally lateralized of all the vertebrates, the flatfishes are an endless source of fascination to all fortunate enough to study them. Although all vertebrates undergo left-right asymmetric internal organ placement during embryogenesis, flatfish are unusual in that they experience an additional period of postembryonic asymmetric remodeling during metamorphosis, and thus deviate from a bilaterally symmetrical body plan more than other vertebrates. As with amphibian metamorphosis, all the developmental programs of flatfish metamorphosis are ultimately under the control of thyroid hormone. At least one gene pathway involved in embryonic organ lateralization (nodal-lefty-pitx2) is re-expressed in the larval stage during flatfish metamorphosis. Aspects of modern flatfish ontogeny, such as the gradual translocation of one eye to the opposite side of the head and the appearance of key neurocranial elements during metamorphosis, seem to elegantly recapitulate flatfish phylogeny. This chapter highlights the current state of knowledge of the developmental biology of flatfish metamorphosis with emphases on the genetic, morphological, behavioral, and evolutionary origins of flatfish asymmetry. Copyright © 2013 Elsevier Inc. All rights reserved.
Hydraulics and geology related to beach restoration in Lee County, Florida. [Captiva Island
NASA Technical Reports Server (NTRS)
Winton, T. (Principal Investigator); Brooks, H. K.; Degner, J.; Ruth, B.
1981-01-01
The erosion problem on Captiva Island is discussed. It is due to a deficit in the sand budget of the littoral drift system; a system with losses due to attrition of the particles and mass losses into the lagoons, to offshore, and to lateral transport. The effect that reopening Blind Pass would have, and the placement of sediment retaining structures in the surf zone at the northern and southern limits of the Captiva beach system, wave examined. A geological approach was used to study the origin and dynamic changes that have occurred. Through hydraulic modeling, changes that will occur by reopening and stabilizing Blind Pass are predicted. It is concluded that if the island is to be stabilized, beach nourishment with proper amounts and particle size is a necessity and that jetties adequate to restrict lateral and offshore losses are essential. It is shown that the reopening of Blind Pass would have minimal effects on the passes to the north and south, and would improve the environmental conditions in the sound with no adverse effects on the beach system.
Klein, Scott A; Nyland, John; Caborn, David N M; Kocabey, Yavuz; Nawab, Akbar
2005-12-01
Adequate tibial bone mineral density (BMD) is essential to soft tissue graft fixation during anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare volumetric bone plug density measurements at the tibial region of interest for ACL reconstruction using a standardized immersion technique and Archimedes' principle. Cancellous bone cores were harvested from the proximal, middle, and distal metaphyseal regions of the lateral tibia and from the standard tibial tunnel location used for ACL reconstruction of 18 cadaveric specimens. Proximal tibial cores displayed 32.6% greater BMD than middle tibial cores and 31.8% greater BMD than distal tibial cores, but did not differ from the BMD of the tibial tunnel cores. Correlational analysis confirmed that the cancellous BMD in the tibial tunnel related to the cancellous BMD of the proximal and distal lateral tibial metaphysis. In conjunction with its adjacent cortical bone, the cancellous BMD of the region used for standard tibial tunnel placement provides an effective foundation for ACL graft fixation. In tibia with poor BMD, bicortical fixation that incorporates cortical bone from the distal tibial tunnel region is recommended.
25 CFR 26.26 - What Job Placement services may I receive?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...
25 CFR 26.26 - What Job Placement services may I receive?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...
25 CFR 26.26 - What Job Placement services may I receive?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...
25 CFR 26.26 - What Job Placement services may I receive?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...
25 CFR 26.26 - What Job Placement services may I receive?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...
Network placement optimization for large-scale distributed system
NASA Astrophysics Data System (ADS)
Ren, Yu; Liu, Fangfang; Fu, Yunxia; Zhou, Zheng
2018-01-01
The network geometry strongly influences the performance of the distributed system, i.e., the coverage capability, measurement accuracy and overall cost. Therefore the network placement optimization represents an urgent issue in the distributed measurement, even in large-scale metrology. This paper presents an effective computer-assisted network placement optimization procedure for the large-scale distributed system and illustrates it with the example of the multi-tracker system. To get an optimal placement, the coverage capability and the coordinate uncertainty of the network are quantified. Then a placement optimization objective function is developed in terms of coverage capabilities, measurement accuracy and overall cost. And a novel grid-based encoding approach for Genetic algorithm is proposed. So the network placement is optimized by a global rough search and a local detailed search. Its obvious advantage is that there is no need for a specific initial placement. At last, a specific application illustrates this placement optimization procedure can simulate the measurement results of a specific network and design the optimal placement efficiently.
DeGue, Sarah; Spatz Widom, Cathy
2009-11-01
Existing research on child welfare interventions as mediators of the criminal consequences of child maltreatment has focused on juvenile delinquency rather than adult criminality. This study uses a prospective sample of 772 maltreated youth to examine out-of-home placement as a mediator of adult criminality. Arrest data were collected from official records when the full sample was a mean age of 31.8, having ample opportunity for involvement with the criminal justice system. Overall, out-of-home placement showed a neutral or slightly positive effect on adult criminality compared to no placement, consistent with earlier findings. However, prior delinquency and placement instability were significant risk factors for adult criminality. Gender, not race, was identified as a significant moderator of the relationship between placement and adult criminality, with different patterns of response to placement for males and females. Thus, whether placement experiences influence adult criminal consequences of child maltreatment might depend on prior delinquency, placement stability, and gender.
ERIC Educational Resources Information Center
Walwei, Ulrich
Since 1994, the German public employment service has not had a monopoly on placement. A new law permits private job placement as an independent activity, but only with a license from the public employment service. Since deregulation, the number of job placement licenses has increased continuously, but the number of placements made by private…
ERIC Educational Resources Information Center
Miller, Howard J.; And Others
This document is a manual for a social work field placement program. The social work field placement is described as a learning experience designed to translate the students' interests, interpersonal abilities, and academic knowledge and theory into the capability of enabling others to solve problems. Expectations of skills to be learned in the…
25 CFR 26.27 - What kind of Job Placement support services can I expect?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...
25 CFR 26.24 - What is the scope of the Job Placement Program?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...
25 CFR 26.27 - What kind of Job Placement support services can I expect?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...
25 CFR 26.24 - What is the scope of the Job Placement Program?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...
25 CFR 26.27 - What kind of Job Placement support services can I expect?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...
25 CFR 26.24 - What is the scope of the Job Placement Program?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...
25 CFR 26.27 - What kind of Job Placement support services can I expect?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...
25 CFR 26.24 - What is the scope of the Job Placement Program?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...
25 CFR 26.11 - What type of Job Placement and Training assistance may be approved?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false What type of Job Placement and Training assistance may be... JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.11 What type of Job Placement and... supplemental assistance that supports job placement or training activities (see subpart B of this part for Job...
25 CFR 26.8 - Where do I go to apply for Job Placement and Training assistance?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Where do I go to apply for Job Placement and Training... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.8 Where do I go to apply for Job Placement and Training assistance? You may apply for Job Placement and Training assistance at the servicing office...
25 CFR 26.3 - What is the purpose of the Job Placement and Training Program?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false What is the purpose of the Job Placement and Training... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.3 What is the purpose of the Job Placement and Training Program? The purpose of the Job Placement and Training Program is to assist eligible applicants to...
Infurna, Frank J; Gerstorf, Denis; Zarit, Steven H
2013-03-01
The current study examined how a key component of caregiving stress processes, global mastery perceptions, changes with placing the care recipient in a nursing home or institution. We also explored the role of primary stressors in accounting for mastery changes with placement and whether characteristics of the caregiver and care recipient moderate reactions to placement. We applied multiphase growth curve models to prospective longitudinal data from 271 caregivers in the Caregiver Stress and Coping Study who experienced placement of their care recipient. Using a time-to/from-placement metric, we found that caregivers typically experienced declines in mastery preceding placement, followed by a significant increase within 1 year after placement and further increases thereafter. Corresponding changes in primary stressors (role overload) mediated the placement-related increase in mastery. Caregivers who reported more depressive symptoms and activities of daily living/instrumental activities of daily living dependencies of the care recipient were more likely to experience larger placement-related increases in mastery perceptions. Our findings suggest that placement alters psychological resources of caregivers and this effect is driven by corresponding changes in primary stressors. Findings also underscore the importance of examining change processes across salient life events and transitions.
Patterns of out-of-home placement decision-making in child welfare.
Chor, Ka Ho Brian; McClelland, Gary M; Weiner, Dana A; Jordan, Neil; Lyons, John S
2013-10-01
Out-of-home placement decision-making in child welfare is founded on the best interest of the child in the least restrictive setting. After a child is removed from home, however, little is known about the mechanism of placement decision-making. This study aims to systematically examine the patterns of out-of-home placement decisions made in a state's child welfare system by comparing two models of placement decision-making: a multidisciplinary team decision-making model and a clinically based decision support algorithm. Based on records of 7816 placement decisions representing 6096 children over a 4-year period, hierarchical log-linear modeling characterized concordance or agreement, and discordance or disagreement when comparing the two models and accounting for age-appropriate placement options. Children aged below 16 had an overall concordance rate of 55.7%, most apparent in the least restrictive (20.4%) and the most restrictive placement (18.4%). Older youth showed greater discordant distributions (62.9%). Log-linear analysis confirmed the overall robustness of concordance (odd ratios [ORs] range: 2.9-442.0), though discordance was most evident from small deviations from the decision support algorithm, such as one-level under-placement in group home (OR=5.3) and one-level over-placement in residential treatment center (OR=4.8). Concordance should be further explored using child-level clinical and placement stability outcomes. Discordance might be explained by dynamic factors such as availability of placements, caregiver preferences, or policy changes and could be justified by positive child-level outcomes. Empirical placement decision-making is critical to a child's journey in child welfare and should be continuously improved to effect positive child welfare outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.
Taylor, Christine; Angel, Liz; Nyanga, Lucy; Dickson, Cathy
2017-10-01
To describe the process and challenges from a project that aimed to develop processes, source new placements and place students primarily in the discipline of nursing, but also occupational therapy, physiotherapy, podiatry, social work, and speech therapy. Clinical experience in health facilities is an essential element of health professional education, yet globally, there is a lack of clinical placements to meet demands. Educational providers are seeking placements in nontraditional facilities, yet little has been reported on the challenges in the process of procuring clinical placements. The project used a descriptive approach within a quality implementation framework. The project was guided by the quality implementation framework that included four critical steps: considerations of the host setting, structuring the implementation, supporting the implementation and improving future applications. A total of 115 new student placements were finalised across six health disciplines, including elderly care, nongovernment organisations and general practice. Sixty-two nursing students were placed in the new placements during the project. Challenges included communication, the time-consuming nature of the process and 'gatekeeping' blocks to obtaining placements. Recommendations included the importance of personal interaction in developing and maintaining relationships, and the need for clear communication processes and documentation. Potential areas for research are also given. There is great potential for growth in establishing new placements outside the traditional placement facilities for nursing and allied health and for expanding already existing nonhospital placements. Clinical professional experiences are essential to any nursing or allied health programme. There is an increasing demand for, and global lack of, clinical placements for nursing and allied health students. The results provide nursing and allied health educators and managers a framework for planning clinical placement procurement, and assisting in decision-making and developing strategies and processes for practice. © 2016 John Wiley & Sons Ltd.
Rodger, Sylvia; Stephens, Elizabeth; Clark, Michele; Ash, Susan; Graves, Nicholas
2011-12-01
Currently in the Australian higher education sector, the productivity benefits of occupational therapy clinical education placements are a contested issue. This article will report results of a study that developed a methodology for documenting time use during placements and investigated the productivity changes associated with occupational therapy clinical education placements in Queensland, Australia. Supervisors' and students' time use during placements and how this changed for supervisors compared to pre- and post-placement is also presented. Using a cohort survey design, participants were students from two Queensland universities, and their supervisors employed by Queensland Health. Time use was recorded in 30 minute blocks according to particular categories. There was a significant increase in supervisors' time spent in patient care activities (F = 94.011(2,12.37 df) , P < 0.001) between pre- and during placement (P < 0.001) and decrease between during and post-placement (P < 0.001). Supervisors' time spent in all non-patient care activities was also significant (F = 4.580(2,16 df) , P = 0.027) increasing between pre- and during placement (P = 0.028). There was a significant decrease in supervisors' time spent in placement activities (F = 5.133(2,19.18 df) , P = 0.016) from during to post-placement. Students spent more time than supervisors in patient care activities while on placement. A novel method for reporting productivity and time-use changes during clinical education programs for occupational therapy has been applied. Supervisors spent considerable time in assessing and managing students and their clinical education role should be seen as core business in standard occupational therapy practice. This paper will contribute to future assessments of the economic impact of student placements for allied health disciplines. © 2011 The Authors. Australian Occupational Therapy Journal © 2011 Occupational Therapy Australia.
An Anatomic Study on Whether the Immature Patella is Centered on an Anteroposterior Radiograph.
Kyriakedes, James C; Liu, Raymond W
2017-03-01
In the operating room, after first obtaining a proper lateral radiograph with the condyles superimposed, a 90-degree rotation of the intraoperative fluoroscopy unit does not always produce an anteroposterior (AP) image with the patella centered. The orthogonality of these 2 views has not been well determined in children. This study was comprised of a radiographic group (35 knees) and a cadaveric group (59 knees). Both cadaveric and clinical images were obtained by resting or positioning the femur with the posterior condyles overlapped, and then taking an orthogonal AP image. Centering of the patella was calculated and multiple regression analysis was performed to determine the relationship between patellar centering and age, sex, ethnicity, mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), and contralateral centering. Mean patellar centering, expressed as the lateral position of the patella with respect to the total condylar width, was 0.08±0.10 in the radiographic group and 0.06±0.03 in the cadaveric group. Positive (lateral) patellar centering in 1 knee had a statistically significant correlation with positive patellar centering in the contralateral knee in both the radiographs and the cadavers. In the radiographic group, there was a statistically significant correlation between femoral varus and valgus deformities and positive patellar centering. In the cadaveric group, there was a statistically significant correlation between tibial valgus and negative (medial) patellar centering. The patella in an immature knee is rarely perfectly centered on a true AP image, and is usually seated slightly laterally within the femoral condyles. Obtaining a true AP intraoperative radiograph is critical to analyzing and correcting valgus and varus deformities, and in the proper placement of implants. When addressing knee deformity one should consider obtaining an AP view orthogonal either to a perfect lateral of the knee or orthogonal to the flexion axis of the knee, particularly when evaluating distal femoral deformity.
Alternate row placement is ineffective for cultural control of Meloidogyne incognita in cotton
2008-01-01
The objective of this study was to determine if planting cotton into the space between the previous year's rows reduces crop loss due to Meloidogyne incognita compared to planting in the same row every year. Row placement had a significant (P ≤ 0.05) effect on nematode population levels only on 8 July 2005. Plots receiving 1,3-dichloropropene plus aldicarb had lower nematode population levels than non-fumigated plots on 24 May and 8 July in 2005, but not in 2004. The effect of nematicide treatment on nematode populations was not affected by row placement. Row placement did not have a significant effect on root galling or yield in 2004 or 2005. Nematicide treatment decreased root galling in all years, and the decrease was not influenced by row placement. Yield was increased by nematicide application in 2004 and 2005, and the increase was not affected by row placement. Percentage yield loss was not affected by row placement. Changing the placement of rows reduced nematode population levels only on one sampling date in one year, but end-of-season root galling and lint yield were not affected by changing the placement of rows, nor was the effect of fumigation on yield influenced by row placement. Therefore, row placement is unlikely to contribute to M. incognita management in cotton. PMID:19440259
The Effect of Product Placement Marketing on Effectiveness of Internet Advertising
NASA Astrophysics Data System (ADS)
Liao, Hsiu-Li; Liu, Su-Houn; Pi, Shih-Ming; Chen, Hui-Ju
Compared to the traditional way of doing advertising, such as ad Banners, internet product placement is now emerging as a promising strategy for advertisers to do their job effectively in this Web 2.0 era. Therefore, this study focuses on the effectiveness of product placement advertising on the Internet. The results show that product prominence (Subtle or Prominent) and presentation of the advertising (Video or Images) significantly impacts the effectiveness of product placement advertising on the Internet, including brand impression, advertising attitude, and intention to click. Product prominence and presentation of the advertisement have an interactive impact. Our findings indicated that presenting the product through videos will enhance higher levels of advertising attitude, brand impression, and intention to click than presenting it through still images. Subtle placements will increase the level of advertising attitude and intention to click more so than prominent placements. But prominent placements increase the brand impression more than the subtle placements.
Humanitarian engineering placements in our own communities
NASA Astrophysics Data System (ADS)
VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.
2010-05-01
There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be transformative for both the student and the community, although this potential is not always seen. In order to investigate the role of local placements, qualitative research interviews were conducted. Thirty-two semi-structured research interviews were conducted and analysed, resulting in a distinct outcome space. It is concluded that local humanitarian engineering placements greatly complement international placements and are strongly recommended if international placements are conducted. More importantly it is seen that we are better suited to address the marginalised in our own community, although it is often easier to see the needs of an outside populace.
SPOT-A SENSOR PLACEMENT OPTIMIZATION TOOL FOR ...
journal article This paper presents SPOT, a Sensor Placement Optimization Tool. SPOT provides a toolkit that facilitates research in sensor placement optimization and enables the practical application of sensor placement solvers to real-world CWS design applications. This paper provides an overview of SPOT’s key features, and then illustrates how this tool can be flexibly applied to solve a variety of different types of sensor placement problems.
C1 lateral mass screw-induced occipital neuralgia: a report of two cases.
Conroy, Eimear; Laing, Alan; Kenneally, Rory; Poynton, A R
2010-03-01
C1-2 polyaxial screw-rod fixation is a relatively new technique. While recognizing the potential for inadvertent vertebral artery injury, there have been few reports in the literature outlining all the possible complications. Aim of this study is to review all cases of C1 lateral mass screws insertion with emphasis on the evaluation of potential structures at risk during the procedure. We retrospectively reviewed all patients in our unit who had C1 lateral mass screw insertion over a 2-year period. The C1 lateral mass screw was inserted as part of an atlantoaxial stabilization or incorporated into a modular occiput/subaxial construct. Outcome measures included clinical and radiological parameters. Clinical indicators included age, gender, neurologic status, surgical indication and the number of levels stabilized. Intraoperative complications including blood loss, vertebral artery injury or dural tears were recorded. Postoperative pain distribution and neurological deficit were recorded. Radiological indicators included postoperative plain radiographs to assess sagittal alignment and to check for screw malposition or construct failure. A total of 18 lateral mass screws were implanted in 9 patients. There were three male and six female patients who had C1 lateral mass screw insertion in this unit. Two patients had atlantoaxial stabilization for C2 fracture. There were four patients with rheumatoid arthritis whose C1 lateral mass screws were inserted as part of an occipitocervical or subaxial cervical stabilization. There was no vertebral artery injury, no cerebrospinal fluid leak and minimal blood loss in all patients. Three patients developed postoperative occipital neuralgia. This neuralgia was transient, in one of the patients having settled at 6-week follow-up. In the other two patients the neuralgia was unresolved at time of latest follow-up but was adequately controlled with appropriate pain management. Postoperatively no patient had radiographic evidence of construct failure and all demonstrated excellent sagittal alignment. It has been reported that the absence of threads on the upper portion of the long shank screw may protect against neural irritation. However, insertion of the C1 lateral mass screw necessitates careful caudal retraction of the C2 dorsal root ganglion. The insertion point for the C1 lateral mass screw is at the junction of the C1 posterior arch and the midpoint of the posterior inferior part of the C1 lateral mass. Two patients in our series suffered occipital neuralgia post-insertion of C1 lateral mass screws. This highlights the potential for damage to the C2 nerve root during C1 lateral mass screw placement.
C1 lateral mass screw-induced occipital neuralgia: a report of two cases
Laing, Alan; Kenneally, Rory; Poynton, A. R.
2009-01-01
C1–2 polyaxial screw-rod fixation is a relatively new technique. While recognizing the potential for inadvertent vertebral artery injury, there have been few reports in the literature outlining all the possible complications. Aim of this study is to review all cases of C1 lateral mass screws insertion with emphasis on the evaluation of potential structures at risk during the procedure. We retrospectively reviewed all patients in our unit who had C1 lateral mass screw insertion over a 2-year period. The C1 lateral mass screw was inserted as part of an atlantoaxial stabilization or incorporated into a modular occiput/subaxial construct. Outcome measures included clinical and radiological parameters. Clinical indicators included age, gender, neurologic status, surgical indication and the number of levels stabilized. Intraoperative complications including blood loss, vertebral artery injury or dural tears were recorded. Postoperative pain distribution and neurological deficit were recorded. Radiological indicators included postoperative plain radiographs to assess sagittal alignment and to check for screw malposition or construct failure. A total of 18 lateral mass screws were implanted in 9 patients. There were three male and six female patients who had C1 lateral mass screw insertion in this unit. Two patients had atlantoaxial stabilization for C2 fracture. There were four patients with rheumatoid arthritis whose C1 lateral mass screws were inserted as part of an occipitocervical or subaxial cervical stabilization. There was no vertebral artery injury, no cerebrospinal fluid leak and minimal blood loss in all patients. Three patients developed postoperative occipital neuralgia. This neuralgia was transient, in one of the patients having settled at 6-week follow-up. In the other two patients the neuralgia was unresolved at time of latest follow-up but was adequately controlled with appropriate pain management. Postoperatively no patient had radiographic evidence of construct failure and all demonstrated excellent sagittal alignment. It has been reported that the absence of threads on the upper portion of the long shank screw may protect against neural irritation. However, insertion of the C1 lateral mass screw necessitates careful caudal retraction of the C2 dorsal root ganglion. The insertion point for the C1 lateral mass screw is at the junction of the C1 posterior arch and the midpoint of the posterior inferior part of the C1 lateral mass. Two patients in our series suffered occipital neuralgia post-insertion of C1 lateral mass screws. This highlights the potential for damage to the C2 nerve root during C1 lateral mass screw placement. PMID:19856190
Scott, Peter J; Navarro, Cesar; Stevenson, Mike; Murphy, John C; Bennett, Johan R; Owens, Colum; Hamilton, Andrew; Manoharan, Ganesh; Adgey, A A Jennifer
2011-01-01
For the assessment of patients with chest pain, the 12-lead electrocardiogram (ECG) is the initial investigation. Major management decisions are based on the ECG findings, both for attempted coronary artery revascularization and risk stratification. The aim of this study was to determine if the current 6 precordial leads (V(1)-V(6)) are optimally located for the detection of ST-segment elevation in ST-segment elevation myocardial infarction (STEMI). We analyzed 528 (38% anterior [200], 44% inferior [233], and 18% lateral [95]) patients with STEMI with both a 12-lead ECG and an 80-lead body surface map (BSM) ECG (Prime ECG, Heartscape Technologies, Bangor, Northern Ireland). Body surface map was recorded within 15 minutes of the 12-lead ECG during the acute event and before revascularization. ST-segment elevation of each lead on the BSM was compared with the corresponding 12-lead precordial leads (V(1)-V(6)) for anterior STEMI. In addition, for lateral STEMI, leads I and aVL of the BSM were also compared; and limb leads II, III, aVF of the BSM were compared with inferior unipolar BSM leads for inferior STEMI. Leads with the greatest mean ST-segment elevation were selected, and significance was determined by analysis of variance of the mean ST segment. For anterior STEMI, leads V(1), V(2), 32, 42, 51, and 57 had the greatest mean ST elevation. These leads are located in the same horizontal plane as that of V(1) and V(2). Lead 32 had a significantly greater mean ST elevation than the corresponding precordial lead V(3) (P = .012); and leads 42, 51, and 57 were also significantly greater than corresponding leads V(4), V(5), V(6), respectively (P < .001). Similar findings were also found for lateral STEMI. For inferior STEMI, the limb leads of the BSM (II, III, and aVF) had the greatest mean ST-segment elevation; and lead III was significantly superior to the inferior unipolar leads (7, 17, 27, 37, 47, 55, and 61) of the BSM (P < .001). Leads placed on a horizontal strip, in line with leads V(1) and V(2), provided the optimal placement for the diagnosis of anterior and lateral STEMI and appear superior to leads V(3), V(4), V(5), and V(6). This is of significant clinical interest, not only for ease and replication of lead placement but also may lead to increased recruitment of patients eligible for revascularization with none or borderline ST-segment elevation on the initial 12-lead ECG. Copyright © 2011 Elsevier Inc. All rights reserved.
Immediate placement of endosseous implants into the extraction sockets.
Ebenezer, Vijay; Balakrishnan, K; Asir, R Vigil Dev; Sragunar, Banu
2015-04-01
Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.
Modified rib pivot lateral thoracotomy: a case series.
Appelgrein, C; Hosgood, G
2018-01-01
To describe a modified rib pivot thoracotomy and its clinical application in client-owned dogs and cats. Case series of 24 dogs and 1 cat requiring a thoracotomy. A lateral thoracic incision over the required thoracic segment was made. The latissimus dorsi muscle was reflected dorsally. The predetermined rib was identified and the periosteum overlying the rib was elevated circumferentially, avoiding the intercostal neurovascular structures. Holes were pre-placed above and below the proposed osteotomy site. The rib was osteotomised and pivoted cranially. The pleura was incised and the required intrathoracic procedure was then performed. The thoracic cavity was closed by pre-placement of a suture through the pre-placed holes within the osteotomised rib. The pleura and intercostal musculature were closed, avoiding the intercostal neurovascular structures. The rib was re-apposed and the lateral approach was closed. The cases included were reviewed for both the rib pivoted as per the procedure required and postoperative complications. The study group comprised 8 Staffordshire Bull Terriers, 2 Poodles, 2 German Shepherd Dogs, 1 each of Basset Hound, Rhodesian Ridgeback, Golden Retriever, Australian Shepherd, Vizsla, Bull Mastiff, Schnauzer, Jack Russell Terrier, Bulldog, Deerhound, Labrador Retriever and Australian Terrier, and 1 cat. A modified rib pivot thoracotomy was performed for lung lobectomy (n = 11), oesophagectomy (7), subtotal pericardectomy (5), patent ductus arteriosus ligation (1) and thoracic duct ligation (1). Follow-up ranged from 2 to 40 weeks postoperatively. Postoperative complications included seroma formation in two dogs. A modified rib pivot thoracotomy should be considered as an alternative lateral thoracic approach with good exposure, minimal complications and low morbidity. © 2018 Australian Veterinary Association.
This is Advertising! Effects of Disclosing Television Brand Placement on Adolescents.
van Reijmersdal, Eva A; Boerman, Sophie C; Buijzen, Moniek; Rozendaal, Esther
2017-02-01
As heavy media users, adolescents are frequently exposed to embedded advertising formats such as brand placements. Because this may lead to unwitting persuasion, regulations prescribe disclosure of brand placements. This study aimed to increase our understanding of the effects of disclosing television brand placements and disclosure duration on adolescents' persuasion knowledge (i.e., recognition of brand placement as being advertising, understanding that brand placement has a persuasive intent and critical attitude toward brand placement) and brand responses (i.e., brand memory and brand attitude). To do so, an earlier study that was conducted among adults was replicated among adolescents aged 13-17 years (N = 221, 44 % female). The present study shows that brand placement disclosure had limited effects on adolescents' persuasion knowledge as it only affected adolescents' understanding of persuasive intent, did not mitigate persuasion, but did increase brand memory. These findings suggest that brand placement disclosure has fundamentally different effects on adolescents than on adults: the disclosures had less effects on activating persuasion knowledge and mitigating persuasion among adolescents than among adults. Implications for advertising disclosure regulation and consequences for advertisers are discussed.
Dental hygiene student experiences in external placements in Australia.
Taylor, Jane A; Hayes, Melanie J; Wallace, Linda
2012-05-01
While placements in external locations are being increasingly used in dental education globally, few studies have explored the student learning experience at such placements. The purpose of this study was to investigate student experiences while on external placement in a baccalaureate dental hygiene program. A self-reporting questionnaire was distributed to final-year dental hygiene students (n=77) at the University of Newcastle, Australia, in 2010. The questionnaire included questions regarding the type of placement, experiences offered, supervision, resources available, and lasting impressions. Responding students were generally positive about their external placement experience and indicated that the majority of facilities provided them with the opportunity to provide direct patient care and perform clinical tasks typical of a practicing hygienist. However, there was a statistically significant difference in their opinions about discipline-focused and community placements. Students indicated that their external placement experience provided opportunities to learn more about time and patient management, including hands-on experience with specific clinical tasks. Ongoing evaluations are necessary to ensure that external placements meet both student needs and intended learning outcomes within dental hygiene programs.
Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa
2017-01-01
Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.
Imms, Christine; Chu, Eli Mang Yee; Guinea, Stephen; Sheppard, Loretta; Froude, Elspeth; Carter, Rob; Darzins, Susan; Ashby, Samantha; Gilbert-Hunt, Susan; Gribble, Nigel; Nicola-Richmond, Kelli; Penman, Merrolee; Gospodarevskaya, Elena; Mathieu, Erin; Symmons, Mark
2017-07-21
Clinical placements are a critical component of the training for health professionals such as occupational therapists. However, with growing student enrolments in professional education courses and workload pressures on practitioners, it is increasingly difficult to find sufficient, suitable placements that satisfy program accreditation requirements. The professional accrediting body for occupational therapy in Australia allows up to 200 of the mandatory 1000 clinical placement hours to be completed via simulation activities, but evidence of effectiveness and efficiency for student learning outcomes is lacking. Increasingly placement providers charge a fee to host students, leading educators to consider whether providing an internal program might be a feasible alternative for a portion of placement hours. Economic analysis of the incremental costs and benefits of providing a traditional versus simulated placement is required to inform decision-making. This study is a pragmatic, non-inferiority, single-blind, multicentre, two-group randomised controlled trial (RCT) with an embedded economic analysis. The RCT will compare a block of 40 hours of simulated placement (intervention) with a 40-hour block of traditional placement (comparator), with a focus on student learning outcomes and delivery costs. Six universities will instigate the educational intervention within their respective occupational therapy courses, randomly assigning their cohort of students (1:1 allocation) to the simulated or traditional clinical placements. The primary outcome is achievement of professional behaviours (e.g. communication, clinical reasoning) as assessed by a post-placement written examination. Secondary outcomes include proportions passing the placement assessed using the Student Practice Evaluation Form-Revised, changes in student confidence pre-/post-placement, student and educator evaluation of the placement experience and cost-effectiveness of simulated versus traditional clinical placements. Comprehensive cost data will be collected for both the simulated and traditional placement programs at each site for economic evaluation. Use of simulation in health-related fields like occupational therapy is common, but these activities usually relate to brief opportunities for isolated skill development. The simulated clinical placement evaluated in this trial is less common because it encapsulates a 5-day block of integrated activities, designed and delivered in a manner intended to emulate best-practice placement experiences. The planned study is rare due to inclusion of an economic analysis that aims to provide valuable information about the relationship between costs and outcomes across participating sites. Australian New Zealand Clinical Trials Registry, ACTRN12616001339448 . Registered 26 September 2016.
2011-11-16
CAPE CANAVERAL, Fla. -- The Space Exploration Technologies Corp. (SpaceX) Dragon capsule is readied for lifting and placement to its cargo ring inside a processing hangar at Cape Canaveral Air Force Station in Florida on Nov. 16. Later, the combination will be attached to the top of a Falcon 9 rocket on Space Launch Complex-40 for the company's next demonstration test flight for NASA's Commercial Orbital Transportation Services (COTS) program. SpaceX is one of two companies under contract with NASA to take cargo to the International Space Station. NASA is working with SpaceX to combine its last two demonstration flights, and if approved, the Falcon 9 rocket would launch the Dragon capsule to the orbiting laboratory for a docking within the next several months. Photo credit: NASA/Kim Shiflett
A residual granuloma in association with a dental implant.
McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D
2012-04-01
At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.
Hetzel, Juergen; Spengler, Werner; Horger, Marius; Boeckeler, Michael
2015-06-01
Endoscopic lung volume reduction is an emerging technique meant to improve lung function parameters, quality of life, and exercise tolerance in patients with severe lung emphysema. This is the first report of lung volume reduction by autologous blood in a patient with non-bullous lung emphysema. A 74-year-old woman with heterogeneous lung emphysema developed accidentally diffuse lobar bleeding immediately after valve placement. Due to persistent hemorrhage, the valves had to be removed shortly thereafter. Despite extraction of the valves, respiratory function of the patient improved rapidly indicated also by a drop in the COPD assessment test questionnaire, 3 months later. This was consistent with both improvement of lung function tests and six-minute walking test.
The Use of Recombinant Human Platelet-Derived Growth Factor for Maxillary Sinus Augmentation.
Kubota, Atsushi; Sarmiento, Hector; Alqahtani, Mohammed Saad; Llobell, Arturo; Fiorellini, Joseph P
The maxillary sinus augmentation procedure has become a predictable treatment to regenerate bone for implant placement. The purpose of this study was to evaluate the effect of recombinant human platelet-derived growth factor BB (rhPDGF-BB) combined with a deproteinized cancellous bovine bone graft for sinus augmentation. The lateral window approach was used for maxillary sinuses with minimal residual bone. After a healing period of 4 months, dental implants were placed and then restored following a 2-month osseointegration period. The result demonstrated increased bone height and ISQ values and a 100% survival rate. This study indicates that the addition of rhPDGF-BB to deproteinized cancellous bovine bone accelerated the healing period in maxillary sinuses with minimal native bone.
Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J
2014-10-01
Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.
A novel biomechanical model assessing continuous orthodontic archwire activation
Canales, Christopher; Larson, Matthew; Grauer, Dan; Sheats, Rose; Stevens, Clarke; Ko, Ching-Chang
2013-01-01
Objective The biomechanics of a continuous archwire inserted into multiple orthodontic brackets is poorly understood. The purpose of this research was to apply the birth-death technique to simulate insertion of an orthodontic wire and consequent transfer of forces to the dentition in an anatomically accurate model. Methods A digital model containing the maxillary dentition, periodontal ligament (PDL), and surrounding bone was constructed from human computerized tomography data. Virtual brackets were placed on four teeth (central and lateral incisors, canine and first premolar), and a steel archwire (0.019″ × 0.025″) with a 0.5 mm step bend to intrude the lateral incisor was virtually inserted into the bracket slots. Forces applied to the dentition and surrounding structures were simulated utilizing the birth-death technique. Results The goal of simulating a complete bracket-wire system on accurate anatomy including multiple teeth was achieved. Orthodontic force delivered by the wire-bracket interaction was: central incisor 19.1 N, lateral incisor 21.9 N, and canine 19.9 N. Loading the model with equivalent point forces showed a different stress distribution in the PDL. Conclusions The birth-death technique proved to be a useful biomechanical simulation method for placement of a continuous archwire in orthodontic brackets. The ability to view the stress distribution throughout proper anatomy and appliances advances understanding of orthodontic biomechanics. PMID:23374936
ERIC Educational Resources Information Center
Cirillo, Mary Grupe
2010-01-01
The purpose of this study was to determine the impact of Virginia school divisions' policy of paying the fee for students to take Advanced Placement exams on Advanced Placement course enrollment, the number of Advanced Placement exams taken by students, the average scores earned and the percent of students earning qualifying scores of 3, 4, or 5…
WAMA: a method of optimizing reticle/die placement to increase litho cell productivity
NASA Astrophysics Data System (ADS)
Dor, Amos; Schwarz, Yoram
2005-05-01
This paper focuses on reticle/field placement methodology issues, the disadvantages of typical methods used in the industry, and the innovative way that the WAMA software solution achieves optimized placement. Typical wafer placement methodologies used in the semiconductor industry considers a very limited number of parameters, like placing the maximum amount of die on the wafer circle and manually modifying die placement to minimize edge yield degradation. This paper describes how WAMA software takes into account process characteristics, manufacturing constraints and business objectives to optimize placement for maximum stepper productivity and maximum good die (yield) on the wafer.
2013-01-01
Objectives. The current study examined how a key component of caregiving stress processes, global mastery perceptions, changes with placing the care recipient in a nursing home or institution. We also explored the role of primary stressors in accounting for mastery changes with placement and whether characteristics of the caregiver and care recipient moderate reactions to placement. Method. We applied multiphase growth curve models to prospective longitudinal data from 271 caregivers in the Caregiver Stress and Coping Study who experienced placement of their care recipient. Results. Using a time-to/from-placement metric, we found that caregivers typically experienced declines in mastery preceding placement, followed by a significant increase within 1 year after placement and further increases thereafter. Corresponding changes in primary stressors (role overload) mediated the placement-related increase in mastery. Caregivers who reported more depressive symptoms and activities of daily living/instrumental activities of daily living dependencies of the care recipient were more likely to experience larger placement-related increases in mastery perceptions. Discussion. Our findings suggest that placement alters psychological resources of caregivers and this effect is driven by corresponding changes in primary stressors. Findings also underscore the importance of examining change processes across salient life events and transitions. PMID:22956053
Peters, Kathleen; Halcomb, Elizabeth J; McInnes, Susan
2013-05-01
As a practice-based discipline a key component of undergraduate nurse education is clinical practice experience. The quality of clinical experiences has a significant impact on the students' ability to function competently post graduation. The relationship between higher education institutions (HEIs) and health service placement providers impacts upon the quality of clinical placements. In Australia, the growth of primary care nursing and the shortage of acute clinical places has prompted HEIs to explore the placement of students in general practice. Given the increasing attention being paid to non-traditional clinical placements, it is timely to explore how universities are establishing relationships and models of clinical placement. This paper uses qualitative research methods to explore the perspectives of 12 Australian general practice nurses who have experience in facilitating undergraduate clinical placements about the relationships between HEIs and nurses. Findings are presented in the following three themes: (1) Appropriate preparation for placement: They don't know what primary health really means, (2) Seeking greater consultation in the organisation of clinical placements: they've got to do it one way for everyone, and (3) Uncertainty and lack of support: I had no contact with the university. Clinical placements in general practice can be an innovative strategy providing non-traditional, yet high quality, teaching and learning experiences for undergraduate nursing students. To optimise the quality of these placements, however, it is essential that HEIs provide appropriate support to the practice nurses mentoring these students. Copyright © 2012 Elsevier Ltd. All rights reserved.
Infant sleep positioning by nursery staff and mothers in newborn hospital nurseries.
Stastny, Penny F; Ichinose, Travers Y; Thayer, Sharon D; Olson, Robert J; Keens, Thomas G
2004-01-01
Although advice from healthcare professionals may influence parental infant placement choice to reduce sudden infant death syndrome risk, literature on nursery staff infant placement behaviors and the degree to which they influence maternal infant sleep positioning is limited. To assess newborn placement practices of the mother and nursery staff and their interrelationship in the hospital setting. A cross-sectional survey-based study was conducted among hospital newborn nursery staff (n = 96) and mothers of newborns (n = 579) at eight perinatal hospitals in Orange County, California. Although a majority of sampled nursery staff (72%) identified the supine position as the placement that most lowers sudden infant death syndrome risk, only 30% reported most often placing infants to sleep in that position, with most staff (91%) citing fear of aspiration as the motivation for supine position avoidance. Only 34% of staff reported advising exclusive supine infant positioning to mothers. Approximately 36% of mothers reported using supine infant placement exclusively. Maternal infant placement choice varied by both the advice (p <.01) and the placement modeling (p <.01) provided by staff, with the highest proportion of usual supine infant placement found among mothers who reported receiving both. A mother's race/ethnicity also affected the reception of exclusive supine placement recommendations (p <.01). Exclusive supine infant placement appears to be underused by both nursery staff and mothers of newborn infants. Culturally grounded educational intervention with nursery staff regarding infant positioning and placement in the hospital setting is indicated.
Garg, Bhavuk; Gupta, Manish; Singh, Menaka; Kalyanasundaram, Dinesh
2018-05-03
Spinal deformities are very challenging to treat and have a great risk of neurological complications due to hardware placement during corrective surgery. Various techniques have been introduced to ensure safe and accurate placement of pedicle screws. Patient-specific screw guides with pre-drawn and pre-validated trajectory seems to be an attractive option. We have focused on developing 3D printing technique for complex spinal deformities in India. This study also aimed to compare the placement of pedicle screw with 3D printing and free hand technique. This is a retrospective comparative clinical study at an academic institutional setting. A total of 20 patients were enrolled during the study, 10 were operated with the help of 3D printing (group 1) and 10 were operated with freehand technique (group 2). Group 1 included 6 congenital, 3 adolescent idiopathic scoliosis (AIS), one post tubercular kyphosis and Group 2 included 5 congenital, 4 AIS and one post tubercular kyphosis patient. Primary outcomes were measured in terms of screw violation and secondary outcome were measured in terms of Surgical time, Blood loss, Radiation exposure (no. of shoots required) and complications. MIMICS v18.0 Software was used for 3D reconstruction from CT scan images of all the patients. 3-Matic software was used to create drill guide. 3-D printer from Stratasys Mojo ABS P 430 model material cartilage (a thermoplastic material) was used for printing of vertebrae model and jigs. Two sample test of proportion was used to compare correctly and wrongly pedicle screw placement with 3D printing and freehand technique. T-test with equal variance was used for operating surgical time and blood loss. This work was carried out by collaboration of Orthopaedics Department, All India Institute of Medical Sciences (AIIMS), New Delhi and Biomedical Engineering Department, Indian Institute of Technology (IIT) Delhi. This project received the grant of USD 60000 from Department of Biotechnology (DBT), Government of India under DBT Innovative young Biotechnologist Award. No study-specific conflicts of interest-associated biases is declared by the authors. No superior or inferior screw violation was observed in any of our patients in either group. We found significant (p=0.03) difference between 2 groups regarding perfect screw placement in favour of 3D printing. There were 13 grade 2 medial perforations in free hand group and 3 in 3D printing group. There was no grade 3 medial perforation in either group. There were 6 grade 2 lateral perforations in free hand group and 7 in 3D printing group were observed. There were 3 grade 3 lateral perforation in free hand group and 2 in 3D printing group were observed. Analysis showed a statistically significant (p-value: 0.005) medial violation in free hand group. Surgical time was significantly (p-value: 0.03) less in 3D printing group as compared to free hand group. Mean Blood loss was higher in free hand group, however it was not statistically significant (p-value: 0.3) in 3D printing group. Fluoroscopic shots required were less in number in 3D printing group in comparison to free hand group. There was no neurological deficit in any of the patient in any group. In our study, focusing on spinal deformities statistically significant higher rate of accurate screw positioning and higher number of inserted screws with 3D printing was possible due to enhanced safety particularly at apical levels. As such, spinal deformities are difficult to treat worldwide. In India, these deformities are often neglected and present at a very late and much more deformed state when their treatment becomes even more challenging. Developing these patient specific drill templates will enable an average spine surgeon to treat these patients with much ease and safety. Copyright © 2018. Published by Elsevier Inc.
Weil, Alexander G; Fallah, Aria; Lewis, Evan C; Bhatia, Sanjiv
2016-11-01
OBJECTIVE Insular lobe epilepsy (ILE) is an under-recognized cause of extratemporal epilepsy and explains some epilepsy surgery failures in children with drug-resistant epilepsy. The diagnosis of ILE usually requires invasive investigation with insular sampling; however, the location of the insula below the opercula and the dense middle cerebral artery vasculature renders its sampling challenging. Several techniques have been described, ranging from open direct placement of orthogonal subpial depth and strip electrodes through a craniotomy to frame-based stereotactic placement of orthogonal or oblique electrodes using stereo-electroencephalography principles. The authors describe an alternative method for sampling the insula, which involves placing insular depth electrodes along the long axis of the insula through the insular apex following dissection of the sylvian fissure in conjunction with subdural electrodes over the lateral hemispheric/opercular region. The authors report the feasibility, advantages, disadvantages, and role of this approach in investigating pediatric insular-opercular refractory epilepsy. METHODS The authors performed a retrospective analysis of all children (< 18 years old) who underwent invasive intracranial studies involving the insula between 2002 and 2015. RESULTS Eleven patients were included in the study (5 boys). The mean age at surgery was 7.6 years (range 0.5-16 years). All patients had drug-resistant epilepsy as defined by the International League Against Epilepsy and underwent comprehensive noninvasive epilepsy surgery workup. Intracranial monitoring was performed in all patients using 1 parasagittal insular electrode (1 patient had 2 electrodes) in addition to subdural grids and strips tailored to the suspected epileptogenic zone. In 10 patients, extraoperative monitoring was used; in 1 patient, intraoperative electrocorticography was used alone without extraoperative monitoring. The mean number of insular contacts was 6.8 (range 4-8), and the mean number of fronto-parieto-temporal hemispheric contacts was 61.7 (range 40-92). There were no complications related to placement of these depth electrodes. All 11 patients underwent subsequent resective surgery involving the insula. CONCLUSIONS Parasagittal transinsular apex depth electrode placement is a feasible alternative to orthogonally placed open or oblique-placed stereotactic methodologies. This method is safe and best suited for suspected unilateral cases with a possible extensive insular-opercular epileptogenic zone.
Yamaguchi, Yoko; Shiota, Makoto; FuJii, Masaki; Sekiya, Michi; Ozeki, Masahiko
2016-01-01
Primary stability after implant placement is essential for osseointegration. It is important to understand the bone/implant interface for analyzing the influence of implant design on primary stability. In this study rigid polyurethane foam is used as artificial bone to evaluate the bone-implant interface and to identify where the torque is being generated during placement. Five implant systems-Straumann-Standard (ST), Straumann-Bone Level (BL), Straumann-Tapered Effect (TE), Nobel Biocare-Brånemark MKIII (MK3), and Nobel Biocare-Brånemark MKIV (MK4)-were used for this experiment. Artificial bone blocks were prepared and the implant was installed. After placement, a metal jig and one side artificial bone block were removed and then the implant embedded in the artificial bone was exposed for observing the bone-implant interface. A digital micro-analyzer was used for observing the contact interface. The insertion torque values were 39.35, 23.78, 12.53, 26.35, and 17.79 N cm for MK4, BL, ST, TE, and MK3, respectively. In ST, MK3, TE, MK4, and BL the white layer areas were 61 × 103 μm(2), 37 × 103 μm(2), 103 × 103 μm(2) in the tapered portion and 84 × 03 μm(2) in the parallel portion, 134 × 103 μm(2), and 98 × 103 μm(2) in the tapered portion and 87 × 103 μm(2) in the parallel portion, respectively. The direct observation method of the implant/artificial bone interface is a simple and useful method that enables the identification of the area where implant retention occurs. A white layer at the site of stress concentration during implant placement was identified and the magnitude of the stress was quantitatively estimated. The site where the highest torque occurred was the area from the thread crest to the thread root and the under and lateral aspect of the platform. The artificial bone debris created by the self-tapping blade accumulated in both the cutting chamber and in the space between the threads and artificial bone.
Image-guided intracranial cannula placement for awake in vivo microdialysis in nonhuman primates
NASA Astrophysics Data System (ADS)
Chen, Antong; Bone, Ashleigh; Hines, Catherine D. G.; Dogdas, Belma; Montgomery, Tamara O.; Michener, Maria; Winkelmann, Christopher T.; Ghafurian, Soheil; Lubbers, Laura S.; Renger, John; Bagchi, Ansuman; Uslaner, Jason M.; Johnson, Colena; Zariwala, Hatim A.
2016-03-01
Intracranial microdialysis is used for sampling neurochemicals and large peptides along with their metabolites from the interstitial fluid (ISF) of the brain. The ability to perform this in nonhuman primates (NHP) e.g., rhesus could improve the prediction of pharmacokinetic (PK) and pharmacodynamics (PD) action of drugs in human. However, microdialysis in rhesus brains is not as routinely performed as in rodents. One challenge is that the precise intracranial probe placement in NHP brains is difficult due to the richness of the anatomical structure and the variability of the size and shape of brains across animals. Also, a repeatable and reproducible ISF sampling from the same animal is highly desirable when combined with cognitive behaviors or other longitudinal study end points. Toward that end, we have developed a semi-automatic flexible neurosurgical method employing MR and CT imaging to (a) derive coordinates for permanent guide cannula placement in mid-brain structures and (b) fabricate a customized recording chamber to implant above the skull for enclosing and safeguarding access to the cannula for repeated experiments. In order to place the intracranial guide cannula in each subject, the entry points in the skull and the depth in the brain were derived using co-registered images acquired from MR and CT scans. The anterior/posterior (A/P) and medial-lateral (M/L) rotation in the pose of the animal was corrected in the 3D image to appropriately represent the pose used in the stereotactic frame. An array of implanted fiducial markers was used to transform stereotactic coordinates to the images. The recording chamber was custom fabricated using computer-aided design (CAD), such that it would fit the contours of the individual skull with minimum error. The chamber also helped in guiding the cannula through the entry points down a trajectory into the depth of the brain. We have validated our method in four animals and our results indicate average placement error of cannula to be 1.20 +/- 0.68 mm of the targeted positions. The approach employed here for derivation of the coordinates, surgical implantation and post implant validation is built using traditional access to surgical and imaging methods without the necessity of intra-operative imaging. The validation of our method lends support to its wider application in most nonhuman primate laboratories with onsite MR and CT imaging capabilities.
Immediate placement of endosseous implants into the extraction sockets
Ebenezer, Vijay; Balakrishnan, K.; Asir, R. Vigil Dev; Sragunar, Banu
2015-01-01
Implant by definition “means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose.” The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by “why late when it can be done immediately.” There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed. PMID:26015721
Kempker, Samantha M; Schmidt, Adam T; Espinosa, Erin M
2017-07-01
Justice-involved youth have high rates of psychiatric diagnoses, and these youth are often placed out-of-home, although evidence identifies several negative implications of juvenile confinement, especially for youth with psychopathology. Furthermore, youth in the justice system may be processed differently based on gender. As males and females tend to manifest symptoms differently, the psychopathology of youth may act to moderate the relationship between gender and placement in the juvenile justice system. The present study used a large, diverse sample (n = 9 851, 19.8 % female) to examine whether youth placed in various types of out-of-home facilities differed in terms of externalizing, internalizing, substance use, or comorbid disorders, and to determine the predictive value of mental health diagnoses in placement decisions. The moderation effect of psychopathology and substance use on the relationship between gender and placement also was explored. The results indicated that each type of disorder differed across placements, with internalizing being most prevalent in non-secure, and externalizing, comorbid, and substance use being most prevalent in secure settings. Mental health diagnoses improved the prediction of placement in each out-of-home placement beyond legal and demographic factors such that externalizing and substance use disorders decreased the likelihood of placement in non-secure settings, and internalizing, externalizing, and substance use disorders increased the likelihood of placement in secure and state-secure facilities. The relationship between internalizing pathology and placement in more secure facilities was moderated by externalizing pathology. The relationship between gender and placement was significantly moderated by mental health such that females with mental health diagnoses receive less secure placements. Implications for policymakers and practitioners are discussed, as well as implications for reforming juvenile justice within a developmental approach.
Ketorolac for Pain Control With Intrauterine Device Placement: A Randomized Controlled Trial
Ngo, Lynn L.; Ward, Kristy K.; Mody, Sheila K.
2015-01-01
Objective To evaluate intramuscular ketorolac compared to placebo saline injection for pain control with intrauterine device (IUD) placement. Methods We conducted a randomized, double-blind, placebo controlled trial between July 2012 and March 2014. Patients received ketorolac 30mg or placebo saline intramuscular injection 30 minutes prior to IUD placement. The primary outcome was pain with IUD placement on a 10cm visual analog scale (VAS). Sample size was calculated to provide 80% power to show a 2.0cm difference (α=0.05) in the primary outcome. Secondary outcomes included pain with study drug injection, speculum insertion, tenaculum placement, uterine sounding, and at 5 and 15 minutes after IUD placement. Results A total of 67 women participated in the study, 33 in the ketorolac arm and 34 in the placebo arm. There were no differences in baseline demographics including age, BMI, and race. There were no differences in median pain scores for IUD placement in the placebo versus ketorolac groups (5.2cm vs 3.6cm, p=0.99). There was a decrease in median pain scores at 5 minutes (2.2cm vs 0.3cm, p=<0.001) and 15 minutes (1.6cm vs 0.1cm, p=<0.001) after IUD placement but no difference for all other time points. Nulliparous participants (n=16, 8 per arm) had a decrease in pain scores with IUD placement (8.1cm vs 5.4cm, p=0.02). In this study, 22% of participants in the placebo group and 18% in the ketorolac group reported injection pain was as painful as IUD placement. Conclusions Ketorolac does not reduce pain with IUD placement but does reduce pain at 5 and 15 minutes after placement. PMID:26241253
Ketorolac for Pain Control With Intrauterine Device Placement: A Randomized Controlled Trial.
Ngo, Lynn L; Ward, Kristy K; Mody, Sheila K
2015-07-01
To evaluate intramuscular ketorolac compared with placebo saline injection for pain control with intrauterine device (IUD) placement. We conducted a randomized, double-blind, placebo-controlled trial between July 2012 and March 2014. Patients received 30 mg ketorolac or placebo saline intramuscular injection 30 minutes before IUD placement. The primary outcome was pain with IUD placement on a 10-cm visual analog scale. Sample size was calculated to provide 80% power to show a 2.0-cm difference (α=0.05) in the primary outcome. Secondary outcomes included pain with study drug injection, speculum insertion, tenaculum placement, uterine sounding, and at 5 and 15 minutes after IUD placement. A total of 67 women participated in the study, 33 in the ketorolac arm and 34 in the placebo arm. There were no differences in baseline demographics including age, body mass index, and race. There were no differences in median pain scores for IUD placement in the placebo compared with ketorolac groups (5.2 compared with 3.6 cm, P=.99). There was a decrease in median pain scores at 5 minutes (2.2 compared with 0.3 cm, P≤.001) and 15 minutes (1.6 compared with 0.1 cm, P≤.001) after IUD placement but no difference for all other time points. Nulliparous participants (n=16, eight per arm) had a decrease in pain scores with IUD placement (8.1 compared with 5.4 cm, P=.02). In this study, 22% of participants in the placebo group and 18% in the ketorolac group reported injection pain was as painful as IUD placement. Ketorolac does not reduce pain with IUD placement but does reduce pain at 5 and 15 minutes after placement. ClinicalTrials.gov; www.clinicaltrials.gov, NCT01664559. I.
Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J
2010-12-01
Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P < .05) than that of torn tendons (1086 ± 388 N-mm and 177 ± 71 N, respectively). For medial suture placement, maximum load, stiffness, and work of intact and torn tendons were similar (P > .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P < .05). Superior pullout resistance of medially placed sutures may provide a strain shielding effect for the lateral row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to suture migration. While clinical factors such as musculotendinous integrity warrant strong consideration for surgical decision making, the present ultrastructural and biomechanical results appear to provide a scientific rationale for double-row rotator cuff repair where sutures are placed more medially at the muscle-tendon junction.
Holzman, Michael A; Hanus, Bryan D; Munz, John W; O'Connor, Daniel P; Brinker, Mark R
2016-06-01
Nonunion of the distal femur after lateral plating is associated with axial malalignment, chronic pain, loss of ambulatory function, and decreased knee ROM. The addition of a medial locking plate with autogenous bone grafting can provide greater stability to allow bone healing and may be used to achieve union in these challenging cases. We wished to determine (1) the proportion of patients who achieve radiographic signs of osseous union for distal femoral nonunions with an in situ lateral plate after treatment with addition of a medial locking plate and autogenous bone grafting, and (2) the frequency and types of complications associated with this treatment. Between 2007 and 2013, we treated 22 patients for 23 distal femoral nonunions, defined as an unhealed fracture with no radiographic signs of osseous union at a mean of 16 months (SD, 13 months) after injury. During that time, we used a treatment algorithm consisting of treatment in one or two stages. The single-stage procedure performed in 16 aseptic nonunions with a stable lateral plate involved addition of a medial locking plate and autogenous bone graft. A two-stage treatment performed in seven nonunions with lateral plate failure involved placement of a new lateral locking plate followed by addition of a medial locking plate with autogenous bone graft at least 2 months after the first procedure. Of the 22 patients treated, 20 had a median followup of 18 months (SD, 6-94 months). We defined osseous union by bridging bone on three of four cortices with absence of a radiolucent line or more than 25% cross-sectional area of bridging bone via CT. Twenty of the 21 nonunions attained radiographic signs of osseous union by 12 months. Six of the 20 patients experienced complications: one patient had a persistent nonunion; four patients underwent removal of symptomatic hardware; and one patient experienced skin breakdown at the bone graft harvest site. A very high proportion of patients achieve union when using medial locking plates to treat distal femoral nonunions after lateral plating of the original injury. Addition of bone graft, staged reconstruction, and revision of the initial lateral plate is indicated when the nonunion is associated with fatigue failure of the initial lateral plate. Level IV, therapeutic study.
5 CFR 9901.516 - Internal placement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Internal placement. 9901.516 Section 9901... PERSONNEL SYSTEM (NSPS) Staffing and Employment External Recruitment and Internal Placement § 9901.516 Internal placement. (a) Determining levels of work and movement within and across career groups. The...
Koplow, Sarah M; Gallo, Agatha M; Knafl, Kathleen A; Vincent, Catherine; Paun, Olimpia; Gruss, Valerie
2015-07-01
Nursing home placement is one of the most challenging aspects of the caregiving journey. A case study approach was used to understand the experiences of caregivers during the first few months following nursing home placement. Two caregivers were selected from a larger qualitative descriptive study because their experiences exemplified smooth and difficult transitions for both themselves and their older family member. The caregivers were interviewed shortly after placement and 3 months post-placement. Four major contextual issues were identified that indicated the similarities and differences between the two cases, including (a) the caregiver's relationship with the older adult during the home caregiving time and post nursing home placement, (b) the circumstances surrounding placement, (c) support systems, and (d) continued involvement in care post-placement. Nursing home staff who understand these issues and address concerns through family-centered care can ease the transition and promote successful collaborations between staff and families. Copyright 2015, SLACK Incorporated.
Strategies for Controlled Placement of Nanoscale Building Blocks
2007-01-01
The capability of placing individual nanoscale building blocks on exact substrate locations in a controlled manner is one of the key requirements to realize future electronic, optical, and magnetic devices and sensors that are composed of such blocks. This article reviews some important advances in the strategies for controlled placement of nanoscale building blocks. In particular, we will overview template assisted placement that utilizes physical, molecular, or electrostatic templates, DNA-programmed assembly, placement using dielectrophoresis, approaches for non-close-packed assembly of spherical particles, and recent development of focused placement schemes including electrostatic funneling, focused placement via molecular gradient patterns, electrodynamic focusing of charged aerosols, and others. PMID:21794185
Broadhurst, S; Mansell, J
2007-04-01
People with intellectual disabilities (IDs) whose behaviour challenges services are at increased risk of placement breakdown. Most previous research has tended to focus on the role of individual characteristics in predicting breakdown. A small number of studies have suggested that service variables may impact on intervention effectiveness and hence placement breakdown. This study used a non-experimental group comparison design to investigate potential differences between two groups of residential homes, one of which had experienced placement breakdown, and one of which had successfully maintained placements in the community. More residents in the breakdown group had inappropriate sexual behaviours but there were no other differences. Services in the breakdown group had more limited procedural guidance for staff, weaker training, supervision and team meetings and less external professional support. Placement characteristics may be an important determinant of community placement success for people with IDs and challenging behaviour. Those selecting and funding residential placements for such people should attend to the technical competence of the placement (in terms of its use of procedural guidance, training and professional advice) and to the extent of support for staff (in terms of training, supervision and team meetings).
Attrill, Stacie; Lincoln, Michelle; McAllister, Sue
2015-06-01
This study aimed to describe perceptions of clinical placement experiences and competency development for international speech-language pathology students and to determine if these perceptions were different for domestic students. Domestic and international students at two Australian universities participated in nine focus group interviews. Thematic analysis led to the identification of two themes shared by international and domestic students and several separate themes. Shared themes identified the important influence of students' relationships with clinical educators, unique opportunities and learning that occurs on placement. International student themes included concerns about their communication skills and the impact of these skills on client progress. They also explored their adjustment to unfamiliar placement settings and relationships, preferring structured placements to assist this adjustment. Domestic student themes explored the critical nature of competency attainment and assessment on placement, valuing placements that enabled them to achieve their goals. The findings of this study suggest that international students experience additional communication, cultural and contextual demands on clinical placement, which may increase their learning requirements. Clinical education practices must be responsive to the learning needs of diverse student populations. Strategies are suggested to assist all students to adjust to the professional and learning expectations of clinical education placements.
Gebhardt, Winifred A; van der Doef, Margot P; Billingy, Nicole; Carstens, Malou; Steenhuis, Ingrid
2012-07-01
Condom purchasing is an important preparation for condom use. The present study examined if products surrounding condoms in the store play a role in preferences for where to buy condoms among young people. Sixty-nine men and 111 women (<30 years) completed an online questionnaire on their preferences for condom placement, associated embarrassment with these placements, and motives for having sex. Fifty percent of men and 70% of women indicated the counter as least preferred placement. Two-fifths of men and women preferred the sensual context, including among sex toys and lubricants; however, the remainder of participants, particularly women, preferred other less sexual contexts. Both the counter and sensual placement were strongly associated with embarrassment, and this, in turn, was predictive of placement preference. Finally, the motive for having sex to experience intimacy was negatively related to counter preference, and the motive for having sex to experience pleasure was negatively related to the neutral placement and the female personal care placement preferences. The findings suggest that using multiple and alternative placements for condoms in stores may encourage condom purchasing behaviour among young people.
Edafe, Ovie; Mistry, Natasha; Chan, Philip
2013-09-01
FAIRness (Feedback, Activity, Individualisation, Relevance) teaching is a structured program, comprising series of classes in which student work is anonymised and reviewed by the whole class, as well as students receiving private feedback on their written work. The class work emphasises logic, structure and order in history and examination, with a diagnostic and management focus. The effect of FAIRness teaching methods on the adaptation of medical students entering their first clinical rotations was studied. 18 students in FAIRness placements and 72 students in conventional placements, all in medical/surgical units in the same University teaching hospital were studied. They completed questionnaires relating to effectiveness and quality of clinical teaching. Some students additionally attended focus groups, at the start of placement to discuss their expectations, and after 3 weeks, to discuss their adaptation to the clinical learning environment. All students entering clinical placements had low expectations of their future teaching. Students in standard placements still expressed negative attitudes after 3 weeks, while students on FAIRness placements felt positive. Students in FAIRness placements scored significantly higher on questions related to feedback and review of student work. FAIRness teaching practices help students to adapt to their first clinical placements.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-31
... training program, which provides vocational/technical training, related counseling, guidance, job placement... the job placement and training program, which provides vocational/technical training, related... Application for Job Placement and Training Services; Request for Comments AGENCY: Bureau of Indian Affairs...
Selected Studies on Math Placement.
ERIC Educational Resources Information Center
Akst, Geoffrey; Hirsch, Lewis
1991-01-01
Drawing from a review of the literature and direct experience, this paper discusses key issues in developmental mathematics placement. First, the controversial practice of mandatory placement is examined, citing research results that support the practice and those that do not. Next, the diversity of developmental math placement standards is…
Humanitarian Engineering Placements in Our Own Communities
ERIC Educational Resources Information Center
VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.
2010-01-01
There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be…
Mathematics Course Placement Using Holistic Measures: Possibilities for Community College Students
ERIC Educational Resources Information Center
Ngo, Federick; Chi, W. Edward; Park, Elizabeth So Yun
2018-01-01
Background/Context: Most community colleges across the country use a placement test to determine students' readiness for college-level coursework, yet these tests are admittedly imperfect instruments. Researchers have documented significant problems stemming from overreliance on placement testing, including placement error and misdiagnosis of…
Impact of an international workplace learning placement on personal and professional development.
Davies, Kerryn; Curtin, Michael; Robson, Kristy
2017-04-01
Workplace learning (WPL) placements are a mandatory part of occupational therapy courses. There is some evidence that suggests WPL placements in international settings are beneficial for students' learning, and personal and professional development. The aim of this study was to explore the impact an international WPL placement in Vietnam had on the perceived personal and professional development of a group of Australian occupational therapy graduates. Interpretative phenomenological analysis was used to explore the perceptions of how participation in the Charles Sturt University School of Community Health's Vietnam placement influenced the personal and professional development of occupational therapy graduates. Individual semi-structured interviews were conducted with nine graduates who participated in the Vietnam placement when they were final year occupational therapy students. Interviews were audio-recorded, transcribed verbatim and individually analysed to identify key themes. Two major themes emerged from the analysis: becoming resourceful, resilient and confident, and becoming respectful of difference. The participants indicated that participation in the Vietnam placement had a positive impact on their personal and professional development. Participants indicated that the Vietnam placement enabled them to develop their resourcefulness, resilience, reasoning skills, cultural competence, confidence and independence, beyond what they felt would have achieved on a domestic placement. For these reason these participants found the placement a beneficial and worthwhile experience. © 2016 Occupational Therapy Australia.
Foster care assessment: A study of the placement decision process in Flanders.
Vanderfaeillie, Johan; Pijnenburg, Huub; Damen, Harm; Van Holen, Frank
2015-11-01
Family foster care placement decision-making has a weak scientific underpinning. Mostly a 'variable-oriented approach' is taken, which requires a lot of information that is not always available. The identification of clusters of foster children with similar characteristics may be a more viable decision strategy. In this study we investigated if foster children could indeed be clustered, which problems were identified at the time of placement, and the influence of placement history. It proved possible to group foster children into two clusters: (1) young children with familial problems and few behavioral problems, and (2) older children with prominent child problems and behavioral problems. For foster children with and without placement history, problems associated with placement proved identical. Considering that a foster care placement did not result in fundamental change in the problems present at time of placement, the importance is stressed of approaching foster care assessment as part of a decision making process which looks back as well as forward. Placement decisions should be based on an appraisal of the appropriateness of foster placement as a solution for the child. In conjunction with this appraisal a decision is required on how parents can be supported toward reunification. Or--if this is not an option--whether long term foster care is the best option for the child and if so, what conditions need to be met. Copyright © 2015 Elsevier Ltd. All rights reserved.
Foster care placement change: The role of family dynamics and household composition
Waid, Jeffrey; Kothari, Brianne H.; Bank, Lew; McBeath, Bowen
2016-01-01
Sibling co-placement and kinship care have each been shown to protect against the occurrence of placement change for youth in substitute care. However, little is known about the effects of different combinations of sibling placement and relative caregiver status on placement change. Nor does the field fully understand how family dynamics may differ in these households. Utilizing data from the Supporting Siblings in Foster Care study, this paper examines family dynamics across four typologies of living composition, and tests the effects of living composition membership on the odds of experiencing a placement change over an 18-month period of time. Findings suggest that across living composition typologies, children who were placed separately from their siblings in non-relative care were more likely to be older, have more extensive placement histories, and experience more placement changes both prior to and during the study than were children in other living composition groups. Family living composition was found to influence the occurrence of placement change. Specifically, children co-placed in kinship care were least likely to experience movement; however, sibling co-placement in non-relative care was also protective. Results reveal the need to conduct additional research into the experiences of children in different family living arrangements, and tailor case management services and supports to children in substitute care accordingly. Implications and future directions are discussed. PMID:27990039
Transpyloric Feeding Tube Placement Using Electromagnetic Placement Device in Children.
Goggans, Margaret; Pickard, Sharon; West, Alina Nico; Shah, Samir; Kimura, Dai
2017-04-01
Transpyloric feeding tubes (TPT) are often recommended in critically ill children. Blind tube placement, however, can be difficult, be time-consuming, and incur multiple radiation exposures. An electromagnetic device (EMD) is available for confirmation of successful placement of TPTs. We conducted a retrospective cohort study to evaluate the efficacy of an EMD for TPT placement in children and determine its impact on placement success, radiation exposure, confirmation time, and cost for tube placement compared with traditional blind TPT placement. Retrospective data were collected in patients receiving a TPT before (pre-EMD group) and after implementation of an EMD (EMD group). Need for radiographic exposure decreased significantly in the EMD group (n = 40) compared with the pre-EMD group (n = 38) (0.6 vs 1.6 x-rays, P < .001). TPTs were placed and confirmed without abdominal x-ray in 21 of 40 patients in the EMD group. There were no serious adverse events such as misplacement into the lung or pneumothorax or perforation injury of the stomach. Successful tube confirmation took a significantly shorter time in the EMD group than in the pre-EMD group (1.45 vs 4.59 hours, P < .0001). There was an estimated cost savings of $245.10 per placement associated with decreased x-ray and fluoroscopy. The use of an EMD in children significantly decreased radiation exposure and confirmation time while maintaining TPT placement success. The use of an EMD can potentially offer large cost savings. Elimination of abdominal x-ray with EMD during TPT placement was achieved without any serious complications in approximately half of the children.
Utilisation of the healthcare system for authentic early experience placements.
Hays, Richard B
2013-01-01
Authentic early experience in clinical contexts adds interest and relevance to basic medical education, and is regarded positively by both learners and teachers. However, with the recent expansion of medical education, the healthcare system appears close to reaching its capacity for student supervision. This study explores the utilisation of the healthcare system for early clinical placements. A secondary analysis was conducted of data from the Medical Schools Outcomes Database, collected from the 2010 annual questionnaire, focusing on the timing, duration and location of clinical placements during 2009 within the first half of basic medical education programs in Australia. Data was received for 67% of Australian medical students, reporting a total of 16 812 early clinical placements that occupied 97 319 days of supervised time in a wide variety of hospital, general practice and Indigenous health contexts, both urban and rural, across the Australian healthcare system. These early placements occupied about 16% of total clinical placement time for all students in all training years during 2009. The majority of these placements were for only a few hours or days; exceptions were longitudinal placements in regional and rural communities at a minority of schools. Early clinical placements may pose significant resource costs for placement providers, particularly supervision time and expertise. As medical education expands and the teaching capacity of the Australian healthcare system appears to reach its limits, it may be necessary to allocate placements according to their specific learning outcomes, prioritise more acute settings for more senior students, and increase capacity in less acute health and social care settings.
Mathematics Placement at the University of Illinois
ERIC Educational Resources Information Center
Ahlgren Reddy, Alison; Harper, Marc
2013-01-01
Data from the ALEKS-based placement program at the University of Illinois is presented visually in several ways. The placement exam (an ALEKS assessment) contains precise item-specific information and the data show many interesting properties of the student populations of the placement courses, which include Precalculus, Calculus, and Business…
Brevard District Plan for Placement and Follow-Up.
ERIC Educational Resources Information Center
Thomas, Olive W.
The Brevard District Plan for placement and follow-up is intended for all secondary students, including dropouts, disadvantaged, adult students, and graduates. The areas of placement may be in gainful employment, educational institutions, or a combination of both. The plan specifies procedures for implementing placement and stipulates the type of…
38 CFR 21.252 - Job development and placement services.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...
38 CFR 21.252 - Job development and placement services.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...
38 CFR 21.252 - Job development and placement services.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...
38 CFR 21.252 - Job development and placement services.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...
7. View showing placement of timber deck placement on chord ...
7. View showing placement of timber deck placement on chord and built up construction of top chord and continuous construction through top panel points, eye bar construction on bottom chord - Bridge No. 2.4, Spanning Boiling Fork Creek at Railroad Milepost JC-2.4, Decherd, Franklin County, TN
VR Placement Policy and Field Office Production. Studies in Placement Monograph No. 5.
ERIC Educational Resources Information Center
Pretz, David S.; And Others
A study examined the relationship between vocational education rehabilitation agency placement policy and field office productivity. A total of 112 counselors and 25 supervisors from twenty-two Division of Vocational Rehabilitation field offices from seven states were given questionnaires covering different facets of placement policy including…
28 CFR 551.24 - Child placement.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...
28 CFR 551.24 - Child placement.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...
28 CFR 551.24 - Child placement.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...
28 CFR 551.24 - Child placement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...
28 CFR 551.24 - Child placement.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...
ERIC Educational Resources Information Center
Cassuto, Leonard
2012-01-01
The practical goal of graduate education is placement of graduates. But what does "placement" mean? Academics use the word without thinking much about it. "Placement" is a great keyword for the graduate-school enterprise. For one thing, its meaning certainly gives a purpose to graduate education. Furthermore, the word is a portal into the way of…
Hard and soft tissue augmentation in a postorthodontic patient: a case report.
Bonacci, Fred J
2011-02-01
A combination of hard and soft tissue grafting is used to augment a thin biotype. A 26-year-old woman with mandibular anterior flaring and Miller Class I and III recessions requested interceptive treatment. Surgery included a full-thickness buccal flap, intramarrow penetrations, bone graft placement, and primary flap closure. Postoperative visits were at 2 and 4 weeks and 2, 3, and 6 months. Stage-two surgery consisted of submerged connective tissue graft placement. Postoperative visits were completed at 2, 4, 6, and 8 weeks and 1 year. Follow-up was completed 3 years after the initial surgery. Interradicular concavities were resolved and gingival biotype was augmented. Soft tissue recession remained at 6 months. Reentry revealed clinical labial plate augmentation; 2 mm was achieved at the lateral incisors and the left central incisor and 3 mm was achieved at the right canine. No bone augmentation was achieved on the left canine and right central incisor. The dehiscence at the right central incisor appeared narrower. Overall, a 2- to 3-mm gain in alveolar bone thickness/height was observed. Two months after stage-two surgery, near complete root coverage was achieved; 1 mm of recession remained on the left central incisor. There was a soft tissue thickness gain of 2 mm without any visual difference in keratinized tissue height. Interradicular concavities were eliminated; the soft tissue was augmented and the gingival biotype was altered. Interdental soft tissue craters remained. One year after connective tissue graft placement, there was near complete root coverage at the left central incisor, which at 2 months experienced residual recession. Interradicular concavities and interdental soft tissue craters were eliminated with soft tissue augmentation, including clinical reestablishment of the mucogingival junction. Clinical stability remained 3 years after the initial surgery, with the patient noting comfort during mastication and routine oral hygiene. A clinical increase in labial plate thickness, in conjunction with soft tissue augmentation, appears to provide for continued stability and decreased potential for future clinical attachment loss.
The use of throat packs in pediatric cleft lip/palate surgery: a retrospective study.
Smarius, B J A; Guillaume, C H A L; Jonker, G; van der Molen, A B Mink; Breugem, C C
2018-02-22
Throat packs are commonly used to prevent ingestion or aspiration of blood and other debris during cleft lip/palate surgery. However, dislodgement or (partial) retainment after extubation could have serious consequences. The aim of the present study was to investigate the effect of omitting pharyngeal packing during cleft lip/palate surgery on the incidence of early postoperative complications in children. A retrospective study was performed on all children who underwent cleft lip/palate surgery at the Wilhelmina Children's Hospital. This study compared the period January 2010 through December 2012 when pharyngeal packing was applied according to local protocol (group A) with the period January 2013 till December 2015 when pharyngeal packing was no longer applied after removal from the protocol (group B). Data were collected for sex, age at operation, cleft lip/palate type, type of repair, lateral incisions, length of hospital stay, and complications in the first 6 weeks after surgery. Early complications included wound dehiscence, postoperative bleeding, infection, fever, upper respiratory tract infection (URTI), and lower respiratory tract infection (LRTI). This study included 489 cleft lip/palate operations (group A n = 246, group B n = 243). A total of 39 (15.9%) early complications were recorded in group A and a total of 40 (16.5%) in group B. There were no significant differences (P = 0.902) in complications between the two groups; however, there was a significant difference (P < 0.001) in length of hospital stay between the two groups (group A 3.6 days vs group B 3.2 days). Omitting routine placement of throat packs in cleft lip/palate surgery was not associated with an increased early postoperative complication rate. Therefore, the traditional, routine placement of a throat pack during cleft lip/palate surgery can be questioned. The traditional, routine placement of a throat pack during cleft lip/palate surgery can be questioned.
Computational Analysis of Stresses Acting on Intermodular Junctions in Thoracic Aortic Endografts
Prasad, Anamika; To, Lillian K.; Gorrepati, Madhu L.; Zarins, Christopher K.; Figueroa, C. Alberto
2011-01-01
Purpose: To evaluate the biomechanical and hemodynamic forces acting on the intermodular junctions of a multi-component thoracic endograft and elucidate their influence on the development of type III endoleak due to disconnection of stent-graft segments. Methods: Three-dimensional computer models of the thoracic aorta and a 4-component thoracic endograft were constructed using postoperative (baseline) and follow-up computed tomography (CT) data from a 69-year-old patient who developed type III endoleak 4 years after stent-graft placement. Computational fluid dynamics (CFD) techniques were used to quantitate the displacement forces acting on the device. The contact stresses between the different modules of the graft were then quantified using computational solid mechanics (CSM) techniques. Lastly, the intermodular junction frictional stability was evaluated using a Coulomb model. Results: The CFD analysis revealed that curvature and length are key determinants of the displacement forces experienced by each endograft and that the first 2 modules were exposed to displacement forces acting in opposite directions in both the lateral and longitudinal axes. The CSM analysis revealed that the highest concentration of stresses occurred at the junction between the first and second modules of the device. Furthermore, the frictional analysis demonstrated that most of the surface area (53%) of this junction had unstable contact. The predicted critical zone of intermodular stress concentration and frictional instability matched the location of the type III endoleak observed in the 4-year follow-up CT image. Conclusion: The region of larger intermodular stresses and highest frictional instability correlated with the zone where a type III endoleak developed 4 years after thoracic stent-graft placement. Computational techniques can be helpful in evaluating the risk of endograft migration and potential for modular disconnection and may be useful in improving device placement strategies and endograft design. PMID:21861748
Wade, Thomas J; Lorbeer, Karly; Awad, Michael M; Woodhouse, Julie; DeClue, Angela; Brunt, L Michael
2015-10-01
We hypothesized that a proficiency-based curriculum administered early in the fourth year to senior medical students (MS4) would achieve outcomes comparable to a similar program administered during surgical internship. MS4 (n = 18) entering any surgical specialty enrolled in a proficiency-based skills curriculum at the beginning of the fourth year that included suturing/knot-tying, on-call problems, laparoscopic, and other skills (urinary catheter, sterile prep/drape, IV placement, informed consent, electrosurgical use). Assessment was at 4-12 weeks after training by a modified Objective Structured Assessment of Technical Skills (OSATS). Suturing and knot tying tasks were assessed by time and OSATS technical proficiency (TP) scores (1 [novice], 3 [proficient], 5 [expert]). Outcomes were compared with PGY-1 residents who received similar training at the beginning of internship and assessment 4-12 weeks later. Data are presented as mean values ± standard deviation; statistical significance was assessed by Student's t test. Fifteen of 18 MS4 (83%) reached proficiency on all 15 tasks, and 2 others were proficient on all but 1 laparoscopic task. Compared with PGY-1s, MS4 were significantly faster for 3 of 5 suturing and tying tasks and total task time (547 ± 63 vs 637 ± 127 s; P < .05). Mean TP scores were similar for both groups (MS4, 3.4 ± 0.5 vs PGY-1, 3.1 ± .57; P = NS). MS4 OSATS scores were higher for IV placement, informed consent, and urinary catheter placement, but lower for prep and drape and for management of on-call problems. MS4 who participate in a proficiency-based curriculum taught early in the fourth year are able to meet proficiency targets in a high percentage of cases. This approach should better prepare MS4 for surgical internship. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhang, Jingwei; Hamilton, Ryan; Li, Ming; Ebraheim, Nabil A; He, Xianfeng; Liu, Jiayong; Zhu, Limei
2015-12-01
An anatomic and radiographic study of placement of sacroiliac screws. The aim of this study was to quantitatively assess the risk of partial cut-out of sacroiliac screws from the sacral ala slope via inlet and outlet view. The partial cut-out of sacroiliac screws from the superior surface of sacral ala can jeopardize the L5 nerve root, which is difficult to identify on the pelvic inlet and outlet views. Computed tomography images of 60 patients without pelvic ring deformity or injury were used to measure the width (on inlet view) and height (on outlet view) of the sacral ala. The angle of the sacral ala slope was measured on lateral view. According to the measured parameters, the theoretical safe trajectories of screw placement were calculated using inverse trigonometric functions. Under fluoroscopic guidance, a sacroiliac screw was placed close to the midline on both inlet and outlet views, including posterosuperior, posteroinferior, anterosuperior, and anteroinferior regions to the midline. The incidence of screw partial cut-out from the superior surface of sacral ala was identified. The measured widths and heights of the sacral alas were 28.1 ± 2.8 and 29.8 ± 3.1 mm, respectively. The average angle between the superior aspect of the S1 vertebral body and the superior aspect of the sacral ala was 37.2 ± 2.5 degrees. The rate of partial cut-out of the screws from the superior surface of sacral ala slope was 12.5% (5/40) in posterosuperior, 0% (0/40) in posteroinferior, 70% (28/40) in anterosuperior, and 20% (8/40) in anteroinferior. To avoid the risk of partial cut-out from sacroiliac screw placement, more precise description should be added to the conventional description: the sacroiliac screws should be placed at the inferior half portion on outlet view and at the posterior half portion on inlet view. 4.
Nousiainen, Markku T; Omoto, Daniel M; Zingg, Patrick O; Weil, Yoram A; Mardam-Bey, Sami W; Eward, William C
2013-02-01
: Femoral neck fractures are among the most common orthopaedic injuries impacting the health care system. Surgical management of such fractures with cannulated screws is a commonly performed procedure. The acquisition of surgical skills necessary to perform this procedure typically involves learning on real patients with fluoroscopic guidance. This study attempts to determine if a novel computer-navigated training model improves the learning of this basic surgical skill. A multicenter, prospective, randomized, and controlled study was conducted using surgical trainees with no prior experience in surgically managing femoral neck fractures. After a training session, participants underwent a pretest by performing the surgical task (screw placement) on a simulated hip fracture using fluoroscopic guidance. Immediately after, participants were randomized into either undergoing a training session using conventional fluoroscopy or computer-based navigation. Immediate posttest, retention (4 weeks later), and transfer tests were performed. Performance during the tests was determined by radiographic analysis of hardware placement. Screw placement by trainees was ultimately equal to the level of an expert surgeon with either training technique. Participants who trained with computer navigation took fewer attempts to position hardware and used less fluoroscopy time than those trained with fluoroscopy. When those trained with fluoroscopy used computer navigation at the transfer test, less fluoroscopy time and dosage was used. The concurrent augmented feedback provided by computer navigation did not affect the learning of this basic surgical skill in surgical novices. No compromise in learning occurred if the surgical novice trained with one type of technology and transferred to using the other. The findings of this study suggest that computer navigation may be safely used to train surgical novices in a basic procedure. This model avoids using both live patients and harmful radiation without a compromise in the acquisition of a 3-dimensional technical skill.
Laterality defects are influenced by timing of treatments and animal model.
Vandenberg, Laura N
2012-01-01
The timing of when the embryonic left-right (LR) axis is first established and the mechanisms driving this process are subjects of strong debate. While groups have focused on the role of cilia in establishing the LR axis during gastrula and neurula stages, many animals appear to orient the LR axis prior to the appearance of, or without the benefit of, motile cilia. Because of the large amount of data available in the published literature and the similarities in the type of data collected across laboratories, I have examined relationships between the studies that do and do not implicate cilia, the choice of animal model, the kinds of LR patterning defects observed, and the penetrance of LR phenotypes. I found that treatments affecting cilia structure and motility had a higher penetrance for both altered gene expression and improper organ placement compared to treatments that affect processes in early cleavage stage embryos. I also found differences in penetrance that could be attributed to the animal models used; the mouse is highly prone to LR randomization. Additionally, the data were examined to address whether gene expression can be used to predict randomized organ placement. Using regression analysis, gene expression was found to be predictive of organ placement in frogs, but much less so in the other animals examined. Together, these results challenge previous ideas about the conservation of LR mechanisms, with the mouse model being significantly different from fish, frogs, and chick in almost every aspect examined. Additionally, this analysis indicates that there may be missing pieces in the molecular pathways that dictate how genetic information becomes organ positional information in vertebrates; these gaps will be important for future studies to identify, as LR asymmetry is not only a fundamentally fascinating aspect of development but also of considerable biomedical importance. Copyright © 2011 International Society of Differentiation. Published by Elsevier B.V. All rights reserved.
Development of a Short-Form Measure of Science and Technology Self-efficacy Using Rasch Analysis
NASA Astrophysics Data System (ADS)
Lamb, Richard L.; Vallett, David; Annetta, Leonard
2014-10-01
Despite an increased focus on science, technology, engineering, and mathematics (STEM) in U.S. schools, today's students often struggle to maintain adequate performance in these fields compared with students in other countries (Cheek in Thinking constructively about science, technology, and society education. State University of New York, Albany, 1992; Enyedy and Goldberg 2004; Mandinach and Lewis 2006). In addition, despite considerable pressure to promote the placement of students into STEM career fields, U.S. placement is relatively low (Sadler et al. in Sci Educ 96(3):411-427, 2012; Subotnik et al. in Identifying and developing talent in science, technology, engineering, and mathematics (STEM): an agenda for research, policy and practice. International handbook, part XII, pp 1313-1326, 2009). One explanation for the decline of STEM career placement in the U.S. rests with low student affect concerning STEM concepts and related content, especially in terms of self-efficacy. Researchers define self-efficacy as the internal belief that a student can succeed in learning, and that understanding student success lies in students' externalized actions or behaviors (Bandura in Psychol Rev 84(2):191-215, 1977). Evidence suggests that high self-efficacy in STEM can result in student selection of STEM in later educational endeavors, culminating in STEM career selection (Zeldin et al. in J Res Sci Teach 45(9):1036-1058, 2007). However, other factors such as proficiency play a role as well. The lack of appropriate measures of self-efficacy can greatly affect STEM career selection due to inadequate targeting of this affective trait and loss of opportunity for early intervention by educators. Lack of early intervention decreases selection of STEM courses and careers (Valla and Williams in J Women Minor Sci Eng 18(1), 2012; Lent et al. in J Couns Psychol 38(4), 1991). Therefore, this study developed a short-form measure of self-efficacy to help identify students in need of intervention.
Tözüm, Tolga F; Dursun, Erhan; Tulunoglu, Ibrahim
2009-03-01
The compromised nature of the residual interradicular bone after extraction of periodontally hopeless maxillary molars often requires a sinus elevation procedure to ideally place the implants to accept future prosthesis. Maxillary sinus elevation surgery is a procedure used to increase the volume of bone mass so that dental implants can be placed. This article documents a sinus floor elevation technique through an extraction socket in a 65-year-old white male with chronic inflammation to increase the bone mass after the extraction of a periodontally involved maxillary molar tooth. Computerized tomography revealed an increased thickness of the sinus membrane, which was attributed to possible chronic sinus inflammation and periodontal inflammation. After consultation with the Department of Otolaryngology, it was diagnosed as chronic inflammation without any contraindication for sinus elevation surgery or implant placement. One month after the extraction, the sinus floor elevation surgery was performed through the extraction socket, and implants were placed 4 months later. An uneventful healing was noted after 6 months of osseointegration; two porcelain-fused-to-metal crowns were fabricated. Clinical follow-up took place every 3 months for 3 years, and successful healing was achieved. The patient was satisfied with the esthetic and functional results of the oral rehabilitation. Sinus floor elevation through an extraction socket without any residual bone, followed by dental implant placement, provided successful functional results and acceptable stability.
Immediate implants placed into infected sockets: a case report with 3-year follow-up.
Naves, Marina de Melo; Horbylon, Bruna Zacharias; Gomes, Camila de Freitas; Menezes, Helder Henrique Machado de; Bataglion, César; Magalhães, Denildo de
2009-01-01
The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.
Vaughn, Denty Paul; Syrcle, Jason Alan; Ball, John E; Elder, Steven H; Gambino, Jennifer Michele; Griffin, Russell L; McLaughlin, Ronald M
2016-11-23
Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short monocortical screws in metaphyseal bone may be contraindicated. Objectives of this study were to evaluate axial pullout strength of two different lengths of monocortical screws placed in various regions of the canine humerus compared to bicortical screws, and to derive cortical thickness and bone density values for those regions using quantitative computed tomography analysis (QCT). The QCT analysis was performed on 36 cadaveric canine humeri for six regions of interest (ROI). A bicortical, short monocortical, or 50% transcortical 3.5 mm screw was implanted in each ROI and axial pullout testing was performed. Bicortical screws were stronger than monocortical screws in all ROI except the lateral epicondylar crest. Short monocortical metaphyseal screws were weaker than those placed in other regions. The 50% transcortical screws were stronger than the short monocortical screws in the condyle. A linear relationship between screw length and pullout strength was observed. Cortical thickness and bone density measurements were obtained from multiple regions of the canine humerus using QCT. Use of short monocortical screws may contribute to failure of locking plate fixation of humeral fractures, especially when placed in the condyle. When bicortical screw placement is not possible, maximizing monocortical screw length may optimize fixation stability for distal humeral fractures.
Atassi, Nazem; Cudkowicz, Merit E; Schoenfeld, David A
2011-07-01
A few studies suggest that non-invasive ventilation (1) and gastric tube (G-tube) may have a positive impact on survival but the effect on functional decline is unclear. Confounding by indication may have produced biased estimates of the benefit seen in some of these retrospective studies. The objective of this study was to evaluate the effects of G-tube and NIV on survival and functional decline using advanced statistical models that adjust for confounding by indications. A database of 331 subjects enrolled in previous clinical trials in ALS was available for analysis. Marginal structural models (MSM) were used to compare the mortality hazards and ALSFRS-R slopes between treatment and non-treatment groups, after adjusting for confounding by indication. Results showed that the placement of a G-tube was associated with an additional 1.42 units/month decline in the ALSFRS-R slope (p < 0.0001) and increased mortality hazard of 0.28 (p = 0.02). The use of NIV had no significant effect on ALSFRS-R decline or mortality. In conclusion, marginal structural models can be used to adjust for confounding by indication in retrospective ALS studies. G-tube placement could be followed by a faster rate of functional decline and increased mortality. Our results may suffer from some of the limitations of retrospective analyses.
Results of surgical excision of urethral prolapse in symptomatic patients.
Hall, Mary E; Oyesanya, Tola; Cameron, Anne P
2017-11-01
Here, we present the clinical presentation and surgical outcomes of women with symptomatic urethral prolapse presenting to our institution over 20 years, and seek to provide treatment recommendations for management of symptomatic urethral prolapse and caruncle. A retrospective review of medical records from female patients who underwent surgery for symptomatic urethral prolapse from June 1995 to August 2015 was performed. Surgical technique consisted of a four-quadrant excisional approach for repair of urethral prolapse. A total of 26 patients were identified with a mean age of 38.8 years (range 3-81). The most common presentations were vaginal bleeding, hematuria, pain, and dysuria. All patients underwent surgical excision of urethral prolapse via a standard approach. Follow-up data was available in 24 patients. Six patients experienced temporary postoperative bleeding, and one patient required placement of a Foley catheter for tamponade. One patient experienced temporary postoperative urinary retention requiring Foley catheter placement. Three patients had visible recurrence of urethral prolapse, for which one later underwent re-excision. Surgical excision of urethral prolapse is a reasonable treatment option in patients who have tried conservative management without relief, as well as in those who present with severe symptoms. Possible complications following excision include postoperative bleeding and recurrence, and patients must be counseled accordingly. In this work, we propose a treatment algorithm for symptomatic urethral prolapse. © 2017 Wiley Periodicals, Inc.
Why are mini-implants lost: the value of the implantation technique!
Romano, Fabio Lourenço; Consolaro, Alberto
2015-01-01
The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.
Huang, Cindy Y; Bory, Christopher T; Caron, Colleen; Tebes, Jacob Kraemer; Connell, Christian M
2014-11-01
Risk assessments allow child and youth services to identify children who are at risk for maltreatment (e.g., abuse, neglect) and help determine the restrictiveness of placements or need for services among youth entering a child welfare system. Despite the use of instruments by many agencies within the U.S. to determine the appropriate placements for youth, research has shown that placement decisions are often influenced by factors such as gender, age, and severity of social-emotional and behavior problems. This study examined ratings of risk across multiple domains using a structured assessment tool used by caseworkers in the Rhode Island child welfare system. The relationship between ratings of risk and placement restrictiveness was also examined. Risk levels varied across placement settings. Multivariate analyses revealed that lower caseworker ratings of parent risk and higher ratings of youth risk were associated with more restrictive placements for youth. Implications for the child welfare system are discussed.
Placement Component, Lincoln Career Education Project. Final Report. March, 1973-June, 1976.
ERIC Educational Resources Information Center
Novak, Carl D.; And Others
The goal of the placement component of the 3-year Lincoln Career Education Project, Nebraska, was to establish placement services for youth of participating project schools. "Placement" referred not only to helping exiting senior high youth find employment, but also to developing the knowledge, skills, and attitudes which lead to…
Materials and Area of Study for Advanced Placement Program in American History.
ERIC Educational Resources Information Center
Santos, Peter A.
This paper describes and evaluates benefits of advanced placement programs and identifies materials which can help high school history classroom teachers develop effective advanced placement programs. An advanced placement program is defined as a program which requires a student to do extensive research and writing throughout the school year.…
Brand placement and consumer choice: an in-store experiment.
Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon
2009-01-01
An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.
37 CFR 211.6 - Methods of affixation and placement of mask work notice.
Code of Federal Regulations, 2010 CFR
2010-07-01
... placement of mask work notice. 211.6 Section 211.6 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES MASK WORK PROTECTION § 211.6 Methods of affixation and placement of mask work notice. (a) General. (1) This section specifies methods of affixation and placement...
25 CFR 26.4 - Who administers the Job Placement and Training Program?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false Who administers the Job Placement and Training Program? 26.4 Section 26.4 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training...
25 CFR 26.12 - Who provides the Job Placement and Training?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The...
25 CFR 26.4 - Who administers the Job Placement and Training Program?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false Who administers the Job Placement and Training Program? 26.4 Section 26.4 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training...
25 CFR 26.12 - Who provides the Job Placement and Training?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The...
25 CFR 26.12 - Who provides the Job Placement and Training?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The...
25 CFR 26.4 - Who administers the Job Placement and Training Program?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true Who administers the Job Placement and Training Program? 26.4 Section 26.4 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training...
25 CFR 26.4 - Who administers the Job Placement and Training Program?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Who administers the Job Placement and Training Program? 26.4 Section 26.4 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training...
Emerging: An Art Field Placement's Impact on Practice
ERIC Educational Resources Information Center
Averett, Paige; Spence, Christina Hall
2018-01-01
This exploratory study examined the experiences of 9 stakeholders in an art gallery field placement during their social work education. The study sought to understand how the nontraditional field placement prepared students for practice. In addition, personality traits of students that best fit the placement was examined. Findings suggest that…
Mathematics Placement Test: Typical Results with Unexpected Outcomes
ERIC Educational Resources Information Center
Ingalls, Victoria
2011-01-01
Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…
Better Prepared, Better Placement: An Online Resource for Health Students
ERIC Educational Resources Information Center
Grace, Sandra; O'Neil, Ross
2014-01-01
Despite calls for better preparation of students and supervisors for clinical placement, few dedicated pre-placement resources have been developed. The aim of this project was to design, pilot, and evaluate an online resource to prepare health students and supervisors for clinical placements. Development of an online resource was informed by the…
Alternative Placements in Initial Teacher Education: An Evaluation
ERIC Educational Resources Information Center
Purdy, Noel; Gibson, Ken
2008-01-01
The paper evaluates a programme of short alternative placements for final-year B.Ed. students in Northern Ireland, which aims to broaden student teachers' experience and develop their transferable skills. The alternative placement programme is set first in an international context of evolving pre-service field placements and then set in a local…
Brand Placement and Consumer Choice: An in-Store Experiment
ERIC Educational Resources Information Center
Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon
2009-01-01
An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.…
Measuring the Value of Placements to Employers: A Cost-Benefit Approach
ERIC Educational Resources Information Center
Wond, Tracey; Rambukwella, Shan
2018-01-01
This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…
Vocational Training and Placement of Severely Disabled Persons. Project Employability--Volume 2.
ERIC Educational Resources Information Center
Wehman, Paul, Ed.; Hill, Mark, Ed.
The document presents 12 papers on the vocational training and placement of severely disabled persons based partly on Project Employability, which involves the placement and on the job training of the severely disabled. Titles and authors include: "Placement of Severely Disabled Individuals into Competitive Employment--A Two Year Progress…
Jones, Susan C
2003-10-01
A major challenge to termite baiting in soil habitats is the prolonged time that it may take for subterranean termites (Isoptera: Rhinotermitidae) to infest stations. The objective of this research study was to determine whether the location of food sources (Sentricon in-ground monitoring stations and wooden monitors) influences the likelihood of infestation by termites. In field trials conducted at 15 structures in central Ohio, standard placement of stations at 3-4.5 m intervals was compared with targeted placements based on evidence of termite activity indoors and outdoors as well as conducive moisture conditions. Termites infested significantly more targeted placements (70/374) than standard placements (35/372) around structures. At the targeted placement sites, termites infested more wooden monitors than Sentricon stations, but this was not statistically significant. This implies that placement, rather than cellulose composition, was the more important factor. Termites first infested stations/monitors an average of 38 d sooner at targeted sites than standard placement sites. This research indicates that evidence of termite activity indoors and outdoors should be a prime consideration when placing in-ground stations.
The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.
Perito, Paul; Wilson, Steven
2016-04-01
Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Malec, J F; Buffington, A L; Moessner, A M; Degiorgio, L
2000-08-01
To evaluate initial placement and 1-year employment outcomes of a Medical/Vocational Case Coordination System (MVCCS) for persons with brain injury (BI) that provides: (1) early case identification and coordination, (2) appropriate medical and vocational rehabilitation interventions, (3) work trials, and (4) supported employment interventions including job coaching. One hundred fourteen Minnesota residents, ages 18 to 65 years, with acquired BI. Five levels of Vocational Independence Scale (VIS). Preinjury employment status (VIS) and years of education, severity of initial injury, time since injury, current impairment/disability as measured by the Rasch-analyzed Staff Mayo-Portland Adaptability Inventory (MPAI), and impaired self-awareness measured by staff rating and the difference between Staff MPAI and Survivor MPAI. At placement, 46% in independent work; 25% in transitional placements; 9% in long-term supported employment; 10% in sheltered work; and 10% not placed. At 1-year follow-up (n = 101), 53% in independent work; 19% in transitional placement; 9% in supported work; 6% in sheltered work; and 13% unemployed. Regression analyses showed time since injury and Rasch Staff MPAI predicted VIS at placement; only VIS at placement independently predicted VIS at 1-year follow-up; Rasch Staff MPAI and preinjury education level predicted time to placement. The MVCCS optimized vocational outcome after BI. Time since injury and impairment/disability best predicted vocational placement. Level of initial placement best predicted employment status at follow-up. Persons with greater disability required more extended time and more extensive rehabilitation services before placement.
Lea, Emma J; Andrews, Sharon; Stronach, Megan; Marlow, Annette; Robinson, Andrew L
2017-07-01
To describe whether an action research approach can be used to build capacity of residential aged care facility staff to support undergraduate nursing students' clinical placements in residential aged care facilities, using development of an orientation programme as an exemplar. Aged care facilities are unpopular sites for nursing students' clinical placements. A contributing factor is the limited capacity of staff to provide students with a positive placement experience. Strategies to build mentor capability to shape student placements and support learning and teaching are critical if nursing students are to have positive placements that attract them to aged care after graduation, an imperative given the increasing care needs of the ageing population worldwide. Action research approach employing mixed-methods data collection (primarily qualitative with a quantitative component). Aged care facility staff (n = 32) formed a mentor group at each of two Tasmanian facilities and met regularly to support undergraduate nursing students (n = 40) during placements. Group members planned, enacted, reviewed and reflected on orientation procedures to welcome students, familiarise them with the facility and prepare them for their placement. Data comprised transcripts from these and parallel student meetings, and orientation data from student questionnaires from two successive placement periods (2011/2012). Problems were identified in the orientation processes for the initial student placements. Mentors implemented a revised orientation programme. Evaluation demonstrated improved programme outcomes for students regarding knowledge of facility operations, their responsibilities and emergency procedures. Action research provides an effective approach to engage aged care facility staff to build their capacity to support clinical placements. Building capacity in the aged care workforce is vital to provide appropriate care for residents with increasing care needs. © 2016 John Wiley & Sons Ltd.
Clark, Bradley C; Davis, Tanya D; El-Sayed Ahmed, Magdy M; McCarter, Robert; Ishibashi, Nobuyuki; Jordan, Christopher P; Kane, Timothy D; Kim, Peter C W; Krieger, Axel; Nath, Dilip S; Opfermann, Justin D; Berul, Charles I
2016-05-01
Epicardial implantable cardioverter-defibrillator (ICD) placement in infants, children, and patients with complex cardiac anatomy requires an open surgical thoracotomy and is associated with increased pain, longer length of stay, and higher cost. The purpose of this study was to compare an open surgical epicardial placement approach with percutaneous pericardial placement of an ICD lead system in an infant piglet model. Animals underwent either epicardial placement by direct suture fixation through a left thoracotomy or minimally invasive pericardial placement with thoracoscopic visualization. Initial lead testing and defibrillation threshold testing (DFT) were performed. After the 2-week survival period, repeat lead testing and DFT were performed before euthanasia. Minimally invasive placement was performed in 8 piglets and open surgical placement in 7 piglets without procedural morbidity or mortality. The mean initial DFT value was 10.5 J (range 3-28 J) in the minimally invasive group and 10.0 J (range 5-35 J) in the open surgical group (P = .90). After the survival period, the mean DFT value was 12.0 J (range 3-20 J) in the minimally invasive group and 12.3 J (range 3-35 J) in the open surgical group (P = .95). All lead and shock impedances, R-wave amplitudes, and ventricular pacing thresholds remained stable throughout the survival period. Compared with open surgical epicardial ICD lead placement, minimally invasive pericardial placement demonstrates an equivalent ability to effectively defibrillate the heart and has demonstrated similar lead stability. With continued technical development and operator experience, the minimally invasive method may provide a viable alternative to epicardial ICD lead placement in infants, children, and adults at risk of sudden cardiac death. Copyright © 2016 Heart Rhythm Society. All rights reserved.
Browne, Caroline A; Fetherston, Catherine M; Medigovich, Kristina
2015-10-01
International clinical placements provide undergraduate nursing students with the opportunity to experience or practice nursing care in diverse countries, settings, and cultures. This systematic review aims to ascertain the current knowledge on international clinical placements offered by undergraduate nursing programs in Australia. It seeks to explore three questions: (1) How have previous experiences of nursing students' international clinical placements been described? (2) How have participants and stakeholders determined if the placement has been successful? And (3) What benefits or challenges have been identified by stakeholders as a result of participating in international clinical placements? A systematic thematic synthesis was undertaken. A search of electronic databases including CINAHL, Proquest Central, Scopus, PubMed, and Health Collection was undertaken between September and October 2014. Key terms including 'international clinical placement', 'study abroad', 'international exchange', 'nursing', and 'Australia' were used to identify articles that appeared in peer-reviewed English language journals and that explored international clinical placements offered to undergraduate nursing students by Australian universities. Eight studies were identified that meet the inclusion criteria, and through thematic analysis, five key themes were identified including developing cultural awareness and competence, providing a global perspective on health care, translation of theory to practice, growing personally through reflection, and overcoming apprehension to successfully meet the challenge. A comparison search of literature from Canada and the United Kingdom revealed that similar themes occurred internationally. Although personal successes were identified by students undertaking international clinical placement, further research is required to identify all stakeholder experiences including those of the educators, the educational institutions, and travel providers supporting these placements and the communities where the placements take place. Copyright © 2015 Elsevier Ltd. All rights reserved.
Browne, Caroline A; Fetherston, Catherine M
2018-07-01
International clinical placements provide undergraduate students with a unique and complex clinical learning environment, to explore cultural awareness, experience different health care settings and achieve clinical competencies. Higher education institutions need to consider how to structure these placements to ensure appropriate and achievable aims and learning outcomes. In this study we described the structure, aims and learning outcomes associated with international clinical placement opportunities currently undertaken by Australian undergraduate nursing students in the Asia region. Forty eight percent (n = 18) of the institutions invited responded. Eight institutions met the inclusion criteria, one of which offered three placements in the region, resulting in 10 international placements for which data were provided. An online survey tool was used to collect data during August and September 2015 on international clinical placements conducted by the participating universities. Descriptive data on type and numbers of placements is presented, along with results from the content analysis conducted to explore data from open ended questions on learning aims and outcomes. One hundred students undertook 10 International Clinical Placements offered in the Asian region by eight universities. Variations across placements were found in the length of placement, the number of students participating, facilitator to student ratios and assessment techniques used. Five categories related to the aims of the programs were identified: 'becoming culturally aware through immersion', 'working with the community to promote health', 'understanding the role of nursing within the health care setting', 'translating theory into professional clinical practice', and 'developing relationships in international learning environments'. Four categories related to learning outcomes were identified: 'understanding healthcare and determinants of health', 'managing challenges', 'understanding the role of culture within healthcare' and 'demonstrating professional knowledge, skills and behaviour'. International clinical placements in the Asia region appear to vary greatly from one education institution to the next with no clear consensus from either this study's findings or the literature on which structure, support and assessments lead to greater student learning. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornelis, F.; Takaki, H.; Laskhmanan, M.
PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the samemore » physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.« less
Haskins, Ivy N; Voeller, Guy R; Stoikes, Nathaniel F; Webb, David L; Chandler, Robert G; Phillips, Sharon; Poulose, Benjamin K; Rosen, Michael J
2017-05-01
The use of mesh during ventral hernia repair (VHR) is a well-accepted concept. However, the ideal location of mesh placement remains strongly debated. Although VHR with onlay mesh placement has historically been associated with a high rate of wound events, this surgical approach is technically less challenging than VHR with sublay mesh placement. The purpose of this study was to compare 30-day wound events after onlay mesh placement with adhesive fixation vs those after sublay mesh placement using the Americas Hernia Society Quality Collaborative database. All patients undergoing elective, open VHR with synthetic mesh placement from January 2013 through January 2016 were identified within the Americas Hernia Society Quality Collaborative. Only patients with clean wounds were included. Patients were divided into 2 groups: onlay mesh placement with the use of adhesive and sublay mesh placement. The association of mesh location with 30-day wound events was investigated using a matched analysis. A total of 1,854 patients met inclusion criteria; 1,761 (95.0%) underwent sublay mesh placement and 93 (5.0%) underwent onlay mesh placement with the use of adhesive. A 2:1 sublay to onlay matched analysis was performed based on factors previously shown to influence wound events after VHR. After matching, both groups had a lower mean Ventral Hernia Working Group grade and fewer associated comorbidities. There was no statistically significant difference between the sublay and onlay groups with respect to 30-day surgical site infections (2.9% vs 5.5%; p = 0.30), surgical site occurrences (15.2% vs 7.7%; p = 0.08), or surgical site occurrences requiring procedural intervention (8.2% vs 5.5%; p = 0.42). Ventral hernia repair with onlay mesh placement is a safe alternative to VHR with sublay mesh placement in low-risk patients. Additional studies are needed to determine the long-term mesh outcomes and recurrence rates in both of these groups. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
A Cognitive Model of College Mathematics Placement
1989-08-01
study focused on the precalculus -- calculus placement decision. The Cognitive model uses novel, or analysis level, placement test items in an attempt to...relative to the requirements of a precalculus course. Placement test scores may be partitioned to give analysis and non-analysis subtest scores which can...67 5.1.1 1989 Intercorrelations ....................................................................... 67 5.1.2 1989 Precalculus -Calculus
ERIC Educational Resources Information Center
Ngo, Federick; Kwon, William W.
2015-01-01
Community college students are often placed in developmental math courses based on the results of a single placement test. However, concerns about accurate placement have recently led states and colleges across the country to consider using other measures to inform placement decisions. While the relationships between college outcomes and such…
ERIC Educational Resources Information Center
Jones, C. M.; Green, J. P.; Higson, H. E.
2017-01-01
This study investigates whether the completion of an optional sandwich work placement enhances student performance in final year examinations. Using Propensity Score Matching, our analysis departs from the literature by controlling for self-selection. Previous studies may have overestimated the impact of sandwich work placements on performance…
25 CFR 26.12 - Who provides the Job Placement and Training?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The Bureau or a...
ERIC Educational Resources Information Center
Lewis, Erin E.; Dozier, Mary; Ackerman, John; Sepulveda-Kozakowski, Sandra
2007-01-01
This study assessed relations among placement instability, inhibitory control, and caregiver-rated child behavior. The sample included 33 adopted children who had experienced placement instability, 42 adopted children who had experienced 1 stable placement, and 27 children never placed in foster care. Five- and 6-year-old children completed the…