Sample records for lbb evaluation procedure

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zdarek, J.; Pecinka, L.

    Leak-before-break (LBB) analysis of WWER type reactors in the Czech and Sloval Republics is summarized in this paper. Legislative bases, required procedures, and validation and verification of procedures are discussed. A list of significant issues identified during the application of LBB analysis is presented. The results of statistical evaluation of crack length characteristics are presented and compared for the WWER 440 Type 230 and 213 reactors and for the WWER 1000 Type 302, 320 and 338 reactors.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Kyoung Mo; Jee, Kye Kwang; Pyo, Chang Ryul

    The basis of the leak before break (LBB) concept is to demonstrate that piping will leak significantly before a double ended guillotine break (DEGB) occurs. This is demonstrated by quantifying and evaluating the leak process and prescribing safe shutdown of the plant on the basis of the monitored leak rate. The application of LBB for power plant design has reduced plant cost while improving plant integrity. Several evaluations employing LBB analysis on system piping based on DEGB design have been completed. However, the application of LBB on main steam (MS) piping, which is LBB applicable piping, has not been performedmore » due to several uncertainties associated with occurrence of steam hammer and dynamic strain aging (DSA). The objective of this paper is to demonstrate the applicability of the LBB design concept to main steam lines manufactured with SA106 Gr.C carbon steel. Based on the material properties, including fracture toughness and tensile properties obtained from the comprehensive material tests for base and weld metals, a parametric study was performed as described in this paper. The PICEP code was used to determine leak size crack (LSC) and the FLET code was used to perform the stability assessment of MS piping. The effects of material properties obtained from tests were evaluated to determine the LBB applicability for the MS piping. It can be shown from this parametric study that the MS piping has a high possibility of design using LBB analysis.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tendera, P.

    At present there are two NPPs equipped with PWR units in Czech Republic. The Dukovany NPP is about ten years in operation (four units 440 MW - WWER model 213) and Temelin NPP is under construction (two units 1000 MW-WWER model 320). Both NPPs were built to Soviet design and according to Soviet regulations and standards but most of equipment for primary circuits was supplied by home manufactures. The objective for the Czech LBB programme is to prove the LBB status of the primary piping systems of these NPPs and the LBB concept is a part of strategy to meetmore » western style safety standards. The reason for the Czech LBB project is a lack of some standard safety facilities, too. For both Dukovany and Temolin NPPs a full LBB analysis should be carried out. The application of LBB to the piping system should be also a cost effective means to avoid installations of pipe whip restraints and jet shields. The Czech regulatory body issued non-mandatory requirement {open_quotes}Leak Before Break{close_quotes} which is in compliance with national legal documents and which is based on the US NRC Regulatory Procedures and US standards (ASME, CODE, ANSI). The requirement has been published in the document {open_quotes}Safety of Nuclear Facilities{close_quotes} No. 1/1991 as {open_quotes}Requirements on the Content and Format of Safety Reports and their Supplements{close_quotes} and consists of two parts (1) procedure for obtaining proof of evidence {open_quotes}Leak Before Break{close_quotes} (2) leak detection systems for the pressurized reactor primary circuit. At present some changes concerning both parts of the above document will be introduced. The reasons for this modifications will be presented.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swamy, S.A.; Bhowmick, D.C.; Prager, D.E.

    The regulatory requirements for postulated pipe ruptures have changed significantly since the first nuclear plants were designed. The Leak-Before-Break (LBB) methodology is now accepted as a technically justifiable approach for eliminating postulation of double-ended guillotine breaks (DEGB) in high energy piping systems. The previous pipe rupture design requirements for nuclear power plant applications are responsible for all the numerous and massive pipe whip restraints and jet shields installed for each plant. This results in significant plant congestion, increased labor costs and radiation dosage for normal maintenance and inspection. Also the restraints increase the probability of interference between the piping andmore » supporting structures during plant heatup, thereby potentially impacting overall plant reliability. The LBB approach to eliminate postulating ruptures in high energy piping systems is a significant improvement to former regulatory methodologies, and therefore, the LBB approach to design is gaining worldwide acceptance. However, the methods and criteria for LBB evaluation depend upon the policy of individual country and significant effort continues towards accomplishing uniformity on a global basis. In this paper the historical development of the U.S. LBB criteria will be traced and the results of an LBB evaluation for a typical Japanese PWR primary loop applying U.S. NRC approved methods will be presented. In addition, another approach using the Japanese LBB criteria will be shown and compared with the U.S. criteria. The comparison will be highlighted in this paper with detailed discussion.« less

  5. Leak-Before-Break: Further developments in regulatory policies and supporting research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkowski, G.M.; Chao, K.-S.

    1990-02-01

    The fourth in a series of international Leak-Before-Break (LBB) Seminars supported in part by the US Nuclear Regulatory Commission was held at the National Central Library in Taipei, Taiwan on May 11 and 12, 1989. The seminar updated the international polices and supporting research on LBB. Attendees included representatives from regulatory agencies, electric utilities, nuclear power plant fabricators, research organizations, and academic institutions. Regulatory policy was the subject of presentations by Mr. G. Arlotto (US NRC, USA) Dr. B. Jarman (AECB, Canada), Dr.P. Milella (ENEA-DISP, Italy), Dr. C. Faidy (EDF/Septen, France ), and Dr. K. Takumi (NUPEC, Japan). A papermore » by Mr. K. Wichman and Mr. A. Lee of the US NRC Office of Nuclear Reactor Regulation is included as background material to these proceedings; it discusses the history and status of LBB applications in US nuclear power plants. In addition, several papers on the supporting research programs described regulatory policy or industry standards for flaw evaluations, e.g., the ASME Section XI code procedures. Supporting research programs were reviewed on the first and second day by several participants from Taiwan, US, Japan, Canada, Italy, and France. Each individual paper has been cataloged separately.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bouchard, P.J.

    A forthcoming revision to the R6 Leak-before-Break Assessment Procedure is briefly described. Practical application of the LbB concepts to safety-critical nuclear plant is illustrated by examples covering both low temperature and high temperature (>450{degrees}C) operating regimes. The examples highlight a number of issues which can make the development of a satisfactory LbB case problematic: for example, coping with highly loaded components, methodology assumptions and the definition of margins, the effect of crack closure owing to weld residual stresses, complex thermal stress fields or primary bending fields, the treatment of locally high stresses at crack intersections with free surfaces, the choicemore » of local limit load solution when predicting ligament breakthrough, and the scope of calculations required to support even a simplified LbB case for high temperature steam pipe-work systems.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roussel, G.

    Leak-Before-Break (LBB) technology has not been applied in the first design of the seven Pressurized Water Reactors the Belgian utility is currently operating. The design basis of these plants required to consider the dynamic effects associated with the ruptures to be postulated in the high energy piping. The application of the LBB technology to the existing plants has been recently approved by the Belgian Safety Authorities but with a limitation to the primary coolant loop. LBB analysis has been initiated for the Doel 3 and Tihange 2 plants to allow the withdrawal of some of the reactor coolant pump snubbersmore » at both plants and not reinstall some of the restraints after steam generator replacement at Doel 3. LBB analysis was also found beneficial to demonstrate the acceptability of the primary components and piping to the new conditions resulting from power uprating and stretch-out operation. LBB analysis has been subsequently performed on the primary coolant loop of the Tihange I plant and is currently being performed for the Doel 4 plant. Application of the LBB to the primary coolant loop is based in Belgium on the U.S. Nuclear Regulatory Commission requirements. However the Belgian Safety Authorities required some additional analyses and put some restrictions on the benefits of the LBB analysis to maintain the global safety of the plant at a sufficient level. This paper develops the main steps of the safety evaluation performed by the Belgian Safety Authorities for accepting the application of the LBB technology to existing plants and summarizes the requirements asked for in addition to the U.S. Nuclear Regulatory Commission rules.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swamy, S.A.; Mandava, P.R.; Bhowmick, D.C.

    The leak-before-break (LBB) methodology is accepted as a technically justifiable approach for eliminating postulation of Double-Ended Guillotine Breaks (DEGB) in high energy piping systems. This is the result of extensive research, development, and rigorous evaluations by the NRC and the commercial nuclear power industry since the early 1970s. The DEGB postulation is responsible for the many hundreds of pipe whip restraints and jet shields found in commercial nuclear plants. These restraints and jet shields not only cost many millions of dollars, but also cause plant congestion leading to reduced reliability in inservice inspection and increased man-rem exposure. While use ofmore » leak-before-break technology saved hundreds of millions of dollars in backfit costs to many operating Westinghouse plants, value-impacts resulting from the application of this technology for future plants are greater on a per plant basis. These benefits will be highlighted in this paper. The LBB technology has been applied extensively to high energy piping systems in operating plants. However, there are differences between the application of LBB technology to an operating plant and to a new plant design. In this paper an approach is proposed which is suitable for application of LBB to a new plant design such as the Westinghouse AP600. The approach is based on generating Bounding Analyses Curves (BAC) for the candidate piping systems. The general methodology and criteria used for developing the BACs are based on modified GDC-4 and Standard Review Plan (SRP) 3.6.3. The BAC allows advance evaluation of the piping system from the LBB standpoint thereby assuring LBB conformance for the piping system. The piping designer can use the results of the BACs to determine acceptability of design loads and make modifications (in terms of piping layout and support configurations) as necessary at the design stage to assure LBB for the, piping systems under consideration.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crutzen, S.; Koble, T.D.; Lemaitre, P.

    Applications of the Leak Before Break (LBB) concept involve the knowledge of flaw presence and characteristics. In Service Inspection is given the responsibility of detecting flaws of a determined importance to locate them precisely and to classify them in broad families. Often LBB concepts application imply the knowledge of flaw characteristics such as through wall depth; length at the inner diameter (ID) or outer diameter (OD) surface; orientation or tilt and skew angles; branching; surface roughness; opening or width; crack tip aspect. Besides detection and characterization, LBB evaluations consider important the fact that a crack could be in the weldmore » material or in the base material or in the heat affected zone. Cracks in tee junctions, in homogenous simple welds and in elbows are not considered in the same way. Essential variables of a flaw or defect are illustrated, and examples of flaws found in primary piping as reported by plant operators or service vendors are given. If such flaw variables are important in the applications of LBB concepts, essential is then the knowledge of the performance achievable by NDE techniques, during an ISI, in detecting such flaws, in locating them and in correctly evaluating their characteristics.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moulin, D.; Chapuliot, S.; Drubay, B.

    For structures like vessels or pipes containing a fluid, the Leak-Before-Break (LBB) assessment requires to demonstrate that it is possible, during the lifetime of the component, to detect a rate of leakage due to a possible defect, the growth of which would result in a leak before-break of the component. This LBB assessment could be an important contribution to the overall structural integrity argument for many components. The aim of this paper is to review some practices used for LBB assessment and to describe how some new R & D results have been used to provide a simplified approach ofmore » fracture mechanics analysis and especially the evaluation of crack shape and size during the lifetime of the component.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Y.J.; Sohn, G.H.; Kim, Y.J.

    Typical LBB (Leak-Before-Break) analysis is performed for the highest stress location for each different type of material in the high energy pipe line. In most cases, the highest stress occurs at the nozzle and pipe interface location at the terminal end. The standard finite element analysis approach to calculate J-Integral values at the crack tip utilizes symmetry conditions when modeling near the nozzle as well as away from the nozzle region to minimize the model size and simplify the calculation of J-integral values at the crack tip. A factor of two is typically applied to the J-integral value to accountmore » for symmetric conditions. This simplified analysis can lead to conservative results especially for small diameter pipes where the asymmetry of the nozzle-pipe interface is ignored. The stiffness of the residual piping system and non-symmetries of geometry along with different material for the nozzle, safe end and pipe are usually omitted in current LBB methodology. In this paper, the effects of non-symmetries due to geometry and material at the pipe-nozzle interface are presented. Various LBB analyses are performed for a small diameter piping system to evaluate the effect a nozzle has on the J-integral calculation, crack opening area and crack stability. In addition, material differences between the nozzle and pipe are evaluated. Comparison is made between a pipe model and a nozzle-pipe interface model, and a LBB PED (Piping Evaluation Diagram) curve is developed to summarize the results for use by piping designers.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wichman, K.; Tsao, J.; Mayfield, M.

    The regulatory application of leak before break (LBB) for operating and advanced reactors in the U.S. is described. The U.S. Nuclear Regulatory Commission (NRC) has approved the application of LBB for six piping systems in operating reactors: reactor coolant system primary loop piping, pressurizer surge, safety injection accumulator, residual heat removal, safety injection, and reactor coolant loop bypass. The LBB concept has also been applied in the design of advanced light water reactors. LBB applications, and regulatory considerations, for pressurized water reactors and advanced light water reactors are summarized in this paper. Technology development for LBB performed by the NRCmore » and the International Piping Integrity Research Group is also briefly summarized.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiselyov, V.A.; Sokov, L.M.

    The LBB regulatory approach adopted in Russia in 1993 as an extra safety barrier is described for advanced WWER 1000 reactor steamline. The application of LBB concept requires the following additional protections. First, the steamline should be a highly qualified piping, performed in accordance with the applicable regulations and guidelines, carefully screened to verify that it is not subjected to any disqualifying failure mechanism. Second, a deterministic fracture mechanics analysis and leak rate evaluation have been performed to demonstrate that postulated through-wall crack that yields 95 1/min at normal operation conditions is stable even under seismic loads. Finally, it hasmore » been verified that the leak detection systems are sufficiently reliable, diverse and sensitive, and that adequate margins exist to detect a through wall crack smaller than the critical size. The obtained results are encouraging and show the possibility of the application of the LBB case to the steamline of advanced WWER 1000 reactor.« less

  14. Overview of large scale experiments performed within the LBB project in the Czech Republic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kadecka, P.; Lauerova, D.

    1997-04-01

    During several recent years NRI Rez has been performing the LBB analyses of safety significant primary circuit pipings of NPPs in Czech and Slovak Republics. The analyses covered the NPPs with reactors WWER 440 Type 230 and 213 and WWER 1000 Type 320. Within the relevant LBB projects undertaken with the aim to prove the fulfilling of the requirements of LBB, a series of large scale experiments were performed. The goal of these experiments was to verify the properties of the components selected, and to prove the quality and/or conservatism of assessments used in the LBB-analyses. In this poster, amore » brief overview of experiments performed in Czech Republic under guidance of NRI Rez is presented.« less

  15. Introducing Eu{sup 2+} into yellow phosphor LiBaB{sub 9}O{sub 15}:Ce{sup 3+}, Dy{sup 3+} as blue emitting source to realize white emission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ting; Li, Panlai, E-mail: li_panlai@126.com; Fu, Nian, E-mail: funian3678@163.com

    A series of Dy{sup 3+}, Ce{sup 3+}/Dy{sup 3+}, Eu{sup 2+}/Dy{sup 3+} and Ce{sup 3+}/Eu{sup 2+}/Dy{sup 3+} doping LiBaB{sub 9}O{sub 15} (LBB) phosphors were synthesized via a high temperature solid-state method. LBB:Dy{sup 3+} cannot create light under ultraviolet radiation, however, LBB:Ce{sup 3+}, Dy{sup 3+} can produce yellow emission under 295 nm excitation. The energy transfer occurs from Ce{sup 3+} to Dy{sup 3+} ions via electric dipole-dipole interaction and the critical distance is estimated to be 21.15 Å based on concentration quenching model. Generally, Eu{sup 2+} ion is a sensitizer to Dy{sup 3+} ion, however, there is only the emission of Eu{supmore » 2+} in LBB:Eu{sup 2+}, Dy{sup 3+}, which means there is no energy transfer from Eu{sup 2+} to Dy{sup 3+} ions. Interestingly enough, when doping Eu{sup 2+} ion into LBB:Ce{sup 3+}, Dy{sup 3+}, white emission can be achieved by increase the blue (350–425 nm) emission intensity. The spectral property, quantum efficiency, CIE chromaticity coordinates and thermal quenching property of LBB:Ce{sup 3+}, Eu{sup 2+}, Dy{sup 3+} are investigated. The results indicate that LBB:Ce{sup 3+}, Eu{sup 2+}, Dy{sup 3+} may be a potential application to white light emitting diodes. - Graphical abstract: LBB:Ce{sup 3+}, Dy{sup 3+} can create white emission by doping Eu{sup 2+} ions. - Highlights: • LBB:Ce{sup 3+}, Dy{sup 3+} can produce white emission by doping Eu{sup 2+} ion. • There is no energy transfer from Eu{sup 2+} to Dy{sup 3+} ions. • Energy transfer occurs from Ce{sup 3+} to Dy{sup 3+} ions. • LBB:Ce{sup 3+}, Eu{sup 2+}, Dy{sup 3+} may be a potential application for white LEDs.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cauquelin, C.

    This paper presents an overview of the use of leak-before-break (LBB) analysis for EPR reactors. EPR is an evolutionary Nuclear Island of the 4 loop x 1500 Mwe class currently in the design phase. Application of LBB to the main coolant lines and resulting design impacts are summarized. Background information on LBB analysis in France and Germany is also presented.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faidy, C.; Gilles, P.

    The objective of the seminar was to present the current state of the art in Leak-Before-Break (LBB) methodology development, validation, and application in an international forum. With particular emphasis on industrial applications and regulatory policies, the seminar provided an opportunity to compare approaches, experiences, and codifications developed by different countries. The seminar was organized into four topic areas: status of LBB applications; technical issues in LBB methodology; complementary requirements (leak detection and inspection); LBB assessment and margins. As a result of this seminar, an improved understanding of LBB gained through sharing of different viewpoints from different countries, permits consideration of:more » simplified pipe support design and possible elimination of loss-of-coolant-accident (LOCA) mechanical consequences for specific cases; defense-in-depth type of applications without support modifications; support of safety cases for plants designed without the LOCA hypothesis. In support of these activities, better estimates of the limits to the LBB approach should follow, as well as an improvement in codifying methodologies. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.« less

  18. Draft Genome Sequence of Lactobacillus delbrueckii subsp. bulgaricus LBB.B5.

    PubMed

    Urshev, Zoltan; Hajo, Karima; Lenoci, Leonardo; Bron, Peter A; Dijkstra, Annereinou; Alkema, Wynand; Wels, Michiel; Siezen, Roland J; Minkova, Svetlana; van Hijum, Sacha A F T

    2016-10-06

    Lactobacillus delbrueckii subsp. bulgaricus LBB.B5 originates from homemade Bulgarian yogurt and was selected for its ability to form a strong association with Streptococcus thermophilus The genome sequence will facilitate elucidating the genetic background behind the contribution of LBB.B5 to the taste and aroma of yogurt and its exceptional protocooperation with S. thermophilus. Copyright © 2016 Urshev et al.

  19. Recent evaluations of crack-opening-area in circumferentially cracked pipes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, S.; Brust, F.; Ghadiali, N.

    1997-04-01

    Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. The leak rates depend on the crack-opening area of the through-wall crack in the pipe. In addition to LBB analyses which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessingmore » temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section XI. The objectives of this study were to review, evaluate, and refine current predictive models for performing crack-opening-area analyses of circumferentially cracked pipes. The results from twenty-five full-scale pipe fracture experiments, conducted in the Degraded Piping Program, the International Piping Integrity Research Group Program, and the Short Cracks in Piping and Piping Welds Program, were used to verify the analytical models. Standard statistical analyses were performed to assess used to verify the analytical models. Standard statistical analyses were performed to assess quantitatively the accuracy of the predictive models. The evaluation also involved finite element analyses for determining the crack-opening profile often needed to perform leak-rate calculations.« less

  20. Determination of leakage areas in nuclear piping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keim, E.

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakagemore » areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.« less

  1. The Second International Piping Integrity Research Group (IPIRG-2) program. Final report, October 1991--April 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopper, A.; Wilowski, G.; Scott, P.

    1997-03-01

    The IPIRG-2 program was an international group program managed by the US NRC and funded by organizations from 15 nations. The emphasis of the IPIRG-2 program was the development of data to verify fracture analyses for cracked pipes and fittings subjected to dynamic/cyclic load histories typical of seismic events. The scope included: (1) the study of more complex dynamic/cyclic load histories, i.e., multi-frequency, variable amplitude, simulated seismic excitations, than those considered in the IPIRG-1 program, (2) crack sizes more typical of those considered in Leak-Before-Break (LBB) and in-service flaw evaluations, (3) through-wall-cracked pipe experiments which can be used to validatemore » LBB-type fracture analyses, (4) cracks in and around pipe fittings, such as elbows, and (5) laboratory specimen and separate effect pipe experiments to provide better insight into the effects of dynamic and cyclic load histories. Also undertaken were an uncertainty analysis to identify the issues most important for LBB or in-service flaw evaluations, updating computer codes and databases, the development and conduct of a series of round-robin analyses, and analyst`s group meetings to provide a forum for nuclear piping experts from around the world to exchange information on the subject of pipe fracture technology. 17 refs., 104 figs., 41 tabs.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eperin, A.P.; Zakharzhevsky, Yu.O.; Arzhaev, A.I.

    A two-year Finnish-Russian cooperation program has been initiated in 1995 to demonstrate the applicability of the leak-before-break concept (LBB) to the primary circuit piping of the Leningrad NPP. The program includes J-R curve testing of authentic pipe materials at full operating temperature, screening and computational LBB analyses complying with the USNRC Standard Review Plan 3.6.3, and exchange of LBB-related information with emphasis on NDE. Domestic computer codes are mainly used, and all tests and analyses are independently carried out by each party. The results are believed to apply generally to RBMK type plants of the first generation.

  3. Passive Fourier-transform infrared spectroscopy of chemical plumes: an algorithm for quantitative interpretation and real-time background removal

    NASA Astrophysics Data System (ADS)

    Polak, Mark L.; Hall, Jeffrey L.; Herr, Kenneth C.

    1995-08-01

    We present a ratioing algorithm for quantitative analysis of the passive Fourier-transform infrared spectrum of a chemical plume. We show that the transmission of a near-field plume is given by tau plume = (Lobsd - Lbb-plume)/(Lbkgd - Lbb-plume), where tau plume is the frequency-dependent transmission of the plume, L obsd is the spectral radiance of the scene that contains the plume, Lbkgd is the spectral radiance of the same scene without the plume, and Lbb-plume is the spectral radiance of a blackbody at the plume temperature. The algorithm simultaneously achieves background removal, elimination of the spectrometer internal signature, and quantification of the plume spectral transmission. It has applications to both real-time processing for plume visualization and quantitative measurements of plume column densities. The plume temperature (Lbb-plume ), which is not always precisely known, can have a profound effect on the quantitative interpretation of the algorithm and is discussed in detail. Finally, we provide an illustrative example of the use of the algorithm on a trichloroethylene and acetone plume.

  4. Exodus! Large-scale displacement and social adjustments of resident Atlantic spotted dolphins (Stenella frontalis) in the Bahamas.

    PubMed

    Herzing, Denise L; Augliere, Bethany N; Elliser, Cindy R; Green, Michelle L; Pack, Adam A

    2017-01-01

    Over the last 20 years, significant habitat shifts have been documented in some populations of cetaceans. On Little Bahama Bank (LBB) there are sympatric communities of resident Atlantic spotted dolphins (Stenella frontalis) and bottlenose dolphins (Tursiops truncatus), monitored since 1985. The size and social structure (three clusters: Northern, Central, Southern) have been stable among the spotted dolphin community with little immigration/emigration, even after large demographic losses (36%) following two major hurricanes in 2004. In 2013 an unprecedented exodus of over 50% (52 individuals) of the spotted dolphin community was documented. The entire Central cluster and a few Northern and Southern individuals relocated 161 km south to Great Bahama Bank (GBB), also home to two sympatric resident communities of spotted dolphins and bottlenose dolphins. During the late summer of 2013 and the summers of 2014 and 2015 both sites were regularly monitored but no former LBB dolphins returned to LBB. Uncharacteristic matriline splits were observed. Social analyses revealed random associations for those spotted dolphins and very little integration between spotted dolphins that moved to GBB (MGBB) and those dolphin resident to GBB (RGBB). Male alliances among spotted dolphins were present, with some altered patterns. On LBB, the operational sex ratio (OSR) was reduced (.40 to .25). OSR for MGBB and RGBB dolphins were similar (.45 and .43). A significant steady decrease in sea surface temperature and chlorophyll a (a proxy for plankton production) occurred on LBB leading up to this exodus. Similar trends were not present over the same period on GBB. The sudden large-scale shift of spotted dolphins from LBB to GBB in association with the gradual decline in certain environmental factors suggests that a possible "tipping point" was reached in prey availability. This study provides a unique view into social and genetic implications of large-scale displacement of stable dolphin communities.

  5. Exodus! Large-scale displacement and social adjustments of resident Atlantic spotted dolphins (Stenella frontalis) in the Bahamas

    PubMed Central

    Herzing, Denise L.; Augliere, Bethany N.; Elliser, Cindy R.; Green, Michelle L.; Pack, Adam A.

    2017-01-01

    Over the last 20 years, significant habitat shifts have been documented in some populations of cetaceans. On Little Bahama Bank (LBB) there are sympatric communities of resident Atlantic spotted dolphins (Stenella frontalis) and bottlenose dolphins (Tursiops truncatus), monitored since 1985. The size and social structure (three clusters: Northern, Central, Southern) have been stable among the spotted dolphin community with little immigration/emigration, even after large demographic losses (36%) following two major hurricanes in 2004. In 2013 an unprecedented exodus of over 50% (52 individuals) of the spotted dolphin community was documented. The entire Central cluster and a few Northern and Southern individuals relocated 161 km south to Great Bahama Bank (GBB), also home to two sympatric resident communities of spotted dolphins and bottlenose dolphins. During the late summer of 2013 and the summers of 2014 and 2015 both sites were regularly monitored but no former LBB dolphins returned to LBB. Uncharacteristic matriline splits were observed. Social analyses revealed random associations for those spotted dolphins and very little integration between spotted dolphins that moved to GBB (MGBB) and those dolphin resident to GBB (RGBB). Male alliances among spotted dolphins were present, with some altered patterns. On LBB, the operational sex ratio (OSR) was reduced (.40 to .25). OSR for MGBB and RGBB dolphins were similar (.45 and .43). A significant steady decrease in sea surface temperature and chlorophyll a (a proxy for plankton production) occurred on LBB leading up to this exodus. Similar trends were not present over the same period on GBB. The sudden large-scale shift of spotted dolphins from LBB to GBB in association with the gradual decline in certain environmental factors suggests that a possible “tipping point” was reached in prey availability. This study provides a unique view into social and genetic implications of large-scale displacement of stable dolphin communities. PMID:28792947

  6. Proceedings of the seminar on Leak-Before-Break: Progress in regulatory policies and supporting research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kashima, K.; Wilkowski, G.M.

    1988-03-01

    The third in a series of international Leak-Before-Break (LBB) Seminars supported in part by the US Nuclear Regulatory Commission was held at TEPCO Hall in the Tokyo Electric Power Company's (TEPCO) Electric Power Museum on May 14 and 15, 1987. The seminar updated the international policies and supporting research on LBB. Attendees included representatives from regulatory agencies, electric utility representatives, fabricators of nuclear power plants, research organizations, and university professors. Regulatory policy was the subject of presentations by Mr. G. Arlotto (US NRC, USA), Dr. H. Schultz (GRS, W. Germany), Dr. P. Milella (ENEA-DISP, Italy), Dr. C. Faidy, P. Jamet,more » and S. Bhandari (EDF/Septen, CEA/CEN, and Framatome, France), and Mr. T. Fukuzawa (MITI, Japan). Dr. F. Nilsson presented revised nondestructive inspection requirements relative to LBB in Sweden. In addition, several papers on the supporting research programs discussed regulatory policy. Questions following the presentations of the papers focused on the impact of various LBB policies or the impact of research findings. Supporting research programs were reviewed on the first and second day by several participants from the US, Japan, Germany, Canada, Italy, Sweden, England, and France.« less

  7. Morphological study of the atrioventricular conduction system and Purkinje fibers in yak.

    PubMed

    Duan, Deyong; Yu, Sijiu; Cui, Yan; Li, Chaoxu

    2017-07-01

    We studied the morphology of the atrioventricular conduction system (AVCS) and Purkinje fibers of the yak. Light and transmission electron microscopy were used to study the histological features of AVCS. The distributional characteristics of the His-bundle, the left bundle branch (LBB), right bundle branch (RBB), and Purkinje fiber network of yak hearts were examined using gross dissection, ink injection, and ABS casting. The results showed that the atrioventricular node (AVN) of yak located in the right side of interatrial septum and had a flattened ovoid shape. The AVN of yak is composed of the slender, interweaving cells formed almost entirely of the transitional cells (T-cells). The His-bundle extended from the AVN, and split into left LBB and RBB at the crest of the interventricular septum. The LBB descended along the left side of interventricular septum. At approximately the upper 1/3 of the interventricular septum, the LBB typically divided into three branches. The RBB ran under the endocardium of the right side of interventricular septum, and extended to the base of septal papillary muscle, passed into the moderator band, crossed the right ventricular cavity to reach the base of anterior papillary muscle, and divided into four fascicles under the subendocardial layer. The Purkinje fibers in the ventricle formed a complex spatial network. The distributional and cellular component characteristics of the AVCS and Purkinje fibers ensured normal cardiac function. © 2017 Wiley Periodicals, Inc.

  8. Evaluation of insecticidal activity of a bacterial strain, Serratia sp. EML-SE1 against diamondback moth.

    PubMed

    Jeong, Hyung Uk; Mun, Hye Yeon; Oh, Hyung Keun; Kim, Seung Bum; Yang, Kwang Yeol; Kim, Iksoo; Lee, Hyang Burm

    2010-08-01

    To identify novel bioinsecticidal agents, a bacterial strain, Serratia sp. EML-SE1, was isolated from a dead larva of the lepidopteran diamondback moth (Plutella xylostella) collected from a cabbage field in Korea. In this study, the insecticidal activity of liquid cultures in Luria-Bertani broth (LBB) and nutrient broth (NB) of a bacterial strain, Serratia sp. EML-SE1 against thirty 3rd and 4th instar larvae of the diamondback moth was investigated on a Chinese cabbage leaf housed in a round plastic cage (Ø 10 x 6 cm). 72 h after spraying the cabbage leaf with LBB and NB cultures containing the bacterial strain, the mortalities of the larvae were determined to be 91.7% and 88.3%, respectively. In addition, the insecticidal activity on potted cabbage containing 14 leaves in a growth cage (165 x 83 x 124 cm) was found to be similar to that of the plastic cage experiment. The results of this study provided valuable information on the insecticidal activity of the liquid culture of a Serratia species against the diamondback moth.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerard, R.; Malekian, C.; Meessen, O.

    The Leak Before Break (LBB) concept allows to eliminate from the design basis the double-ended guillotine break of the primary loop piping, provided it can be demonstrated by a fracture mechanics analysis that a through-wall flaw, of a size giving rise to a leakage still well detectable by the plant leak detection systems, remains stable even under accident conditions (including the Safe Shutdown Earthquake (SSE)). This concept was successfully applied to the primary loop piping of several Belgian Pressurized Water Reactor (PWR) units, operated by the Utility Electrabel. One of the main benefits is to permit justification of supports inmore » the primary loop and justification of the integrity of the reactor pressure vessel and internals in case of a Loss Of Coolant Accident (LOCA) in stretch-out conditions. For two of the Belgian PWR units, the LBB approach also made it possible to reduce the number of large hydraulic snubbers installed on the primary coolant pumps. Last but not least, the LBB concept also facilitates the steam generator replacement operations, by eliminating the need for some pipe whip restraints located close to the steam generator. In addition to the U.S. regulatory requirements, the Belgian safety authorities impose additional requirements which are described in details in a separate paper. An novel aspect of the studies performed in Belgium is the way in which residual loads in the primary loop are taken into account. Such loads may result from displacements imposed to close the primary loop in a steam generator replacement operation, especially when it is performed using the {open_quote}two cuts{close_quotes} technique. The influence of such residual loads on the LBB margins is discussed in details and typical results are presented.« less

  10. The normal variants in the left bundle branch system.

    PubMed

    Elizari, M V

    This article reviewed the main anatomic and physiopathological aspects of the left bundle branch from its origin in the His bundle and its intraventricular distribution on the left endocardial surface. The results are based on the relevant literature and on personal observations executed on 206 hearts distributed as follows: 67 dogs, 60 humans, 45 sheep, 22 pigs, 10 cows, 2 monkeys, 1 guanaco, and 1 sea lion. The main anatomical features of the His-Purkinje conducting system may be summarized as follows: The bundle of His is composed by two segments: the penetrating and branching portions. LBB originates in the branching portion located underneath the membranous septum. There is no true bifurcation of the bundle of His in a human heart. Short after its origin the LBB gives rise to its two main fascicles, anterior and posterior, both heading the anterior and posterior papillary muscles, respectively. The anterior division is thinner and longer than the posterior one. The RBB and the most anterior fibers of the LBB arise at the end of the branching portion. In some cases a well-defined left septal fascicle can be identified, usually arising from the posterior division. Each division gives off small fibers and false tendons crossing the left ventricular cavity connecting the papillary between them or the papillary muscles with the septal surface. From each division of the LBB, their corresponding Purkinje networks emerge covering the subendocardium of the septum and the free wall of the left ventricles. There are critical relationships of the proximal segments of the His-Purkinje system with the surrounding cardiac structures whose pathologic processes may damage the conducting tissue. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chattopadhyay, J.; Dutta, B.K.; Kushwaha, H.S.

    Leak-Before-Break (LBB) is being used to design the primary heat transport piping system of 500 MWe Indian Pressurized Heavy Water Reactors (IPHWR). The work is categorized in three directions to demonstrate three levels of safety against sudden catastrophic break. Level 1 is inherent in the design procedure of piping system as per ASME Sec.III with a well defined factor of safety. Level 2 consists of fatigue crack growth study of a postulated part-through flaw at the inside surface of pipes. Level 3 is stability analysis of a postulated leakage size flaw under the maximum credible loading condition. Developmental work relatedmore » to demonstration of level 2 and level 3 confidence is described in this paper. In a case study on fatigue crack growth on PHT straight pipes for level 2, negligible crack growth is predicted for the life of the reactor. For level 3 analysis, the R6 method has been adopted. A database to evaluate SIF of elbows with throughwall flaws under combined internal pressure and bending moment has been generated to provide one of the inputs for R6 method. The methodology of safety assessment of elbow using R6 method has been demonstrated for a typical pump discharge elbow. In this analysis, limit load of the cracked elbow has been determined by carrying out elasto-plastic finite element analysis. The limit load results compared well with those given by Miller. However, it requires further study to give a general form of limit load solution. On the experimental front, a set of small diameter pipe fracture experiments have been carried out at room temperature and 300{degrees}C. Two important observations of the experiments are - appreciable drop in maximum load at 300{degrees}C in case of SS pipes and out-of-plane crack growth in case of CS pipes. Experimental load deflection curves are finally compared with five J-estimation schemes predictions. A material database of PHT piping materials is also being generated for use in LBB analysis.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anikovsky, V.V.; Karzov, G.P.; Timofeev, B.T.

    The paper demonstrates an insufficiency of some requirements native Norms (when comparing them with the foreign requirements for the consideration of calculating situations): (1) leak before break (LBB); (2) short cracks; (3) preliminary loading (warm prestressing). In particular, the paper presents (1) Comparison of native and foreign normative requirements (PNAE G-7-002-86, Code ASME, BS 1515, KTA) on permissible stress levels and specifically on the estimation of crack initiation and propagation; (2) comparison of RF and USA Norms of pressure vessel material acceptance and also data of pressure vessel hydrotests; (3) comparison of Norms on the presence of defects (RF andmore » USA) in NPP vessels, developments of defect schematization rules; foundation of a calculated defect (semi-axis correlation a/b) for pressure vessel and piping components: (4) sequence of defect estimation (growth of initial defects and critical crack sizes) proceeding from the concept LBB; (5) analysis of crack initiation and propagation conditions according to the acting Norms (including crack jumps); (6) necessity to correct estimation methods of ultimate states of brittle an ductile fracture and elastic-plastic region as applied to calculating situation: (a) LBB and (b) short cracks; (7) necessity to correct estimation methods of ultimate states with the consideration of static and cyclic loading (warm prestressing effect) of pressure vessel; estimation of the effect stability; (8) proposals on PNAE G-7-002-86 Norm corrections.« less

  13. Kinetics of α-MnOOH Nanoparticle Formation through Enzymatically Catalyzed Biomineralization inside Apoferritin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui, Yue; Jung, Haesung; Kim, Doyoon

    While biomineralization in apoferritin has effectively synthesized highly monodispersed nanoparticles of various metal oxides and hydroxides, the detailed kinetics and mechanisms of Mn(III) (hydr)oxide formation inside apoferritin cavities have not been reported. To address this knowledge gap, we first identified the phase of solid Mn(III) formed inside apoferritin cavities as α-MnOOH. To analyze the oxidation and nucleation mechanism of α-MnOOH inside apoferritin by quantifying oxidized Mn, we used a colorimetric method with leucoberbelin blue (LBB) solution. In this method, LBB disassembled apoferritin by inducing an acidic pH environment, and reduced α-MnOOH nanoparticles. The LBB-enabled kinetic analyses of α-MnOOH nanoparticle formationmore » suggested that the orders of reaction with respect to Mn2+ and OH– are 2 and 4, respectively, and α-MnOOH formation follows two-step pathways: First, soluble Mn2+ undergoes apoferritin-catalyzed oxidation at the ferroxidase dinuclear center, forming a Mn(III)-protein complex, P-[Mn2O2(OH)2]. Second, the oxidized Mn(III) dissociates from the protein binding sites and is subsequently nucleated to form α-MnOOH nanoparticles in the apoferritin cavities. This study reveals key kinetics and mechanistic information on the Mn-apoferritin systems, and the results facilitate applications of apoferritin as a means of nanomaterial synthesis.« less

  14. Distribution of surfactant protein A in rat lung.

    PubMed

    Doyle, I R; Barr, H A; Nicholas, T E

    1994-10-01

    Although surfactant protein A (SP-A) is an integral component of alveolar surfactant, its relative abundance in lamellar bodies, regarded as the intracellular storage organelles for surfactant, remains contentious. We have previously shown that lamellar bodies, isolated from rat lung by upward flotation on a sucrose gradient, can be subfractionated into classic-appearing lamellar bodies (Lb-A) and a vesicular fraction (Lb-B), which we have speculated may be a second release form of surfactant. In the present study, we have used two-dimensional protein electrophoresis and immunochemical analysis to clarify the origin and the composition of these two subcellular fractions. In addition, we have examined the hypothesis that the secretion of SP-A and surfactant phospholipids occurs by independent pathways by examining the distribution of SP-A, total protein, and disaturated phospholipids (DSP) in the tubular myelin-rich (Alv-1) and tubular myelin-poor (Alv-2) fractions separated from lavaged material and in Lb-A and Lb-B isolated from both lung homogenate and purified alveolar type II cells. Our findings indicate that Lb-B is derived from type II cells, although they do not indicate whether it is a secretory form of surfactant, a reuptake vesicle, or a mixture of both. We found that the lung has a large tissue pool of immunoreactive SP-A. The %SP-A/DSP of total lamellar bodies isolated from type II cells was 0.96 +/- 0.1 (mean +/- SE), intermediate between that in Lb-A (1.67 +/- 0.13) and in Lb-B (0.65 +/- 0.04). In contrast, the %SP-A/DSP was 11.16 +/- 0.84 in whole lung homogenate and 13.14 +/- 1.71 in whole type II cells. In the alveolar compartment, the %SP-A/DSP was 17.38 +/- 3.40 in Alv-1, 6.34 +/- 0.31 in Alv-2, and 10.49 +/- 1.43 in macrophages, values an order of magnitude greater than found with the lamellar bodies. Our results indicate that only a relatively small portion of alveolar SP-A is derived from lamellar bodies, and we suggest that secretion of SP-A and DSP occurs via independent pathways.

  15. Structural influence of mixed transition metal ions on lithium bismuth borate glasses

    NASA Astrophysics Data System (ADS)

    Yadav, Arti; Dahiya, Manjeet S.; Hooda, A.; Chand, Prem; Khasa, S.

    2017-08-01

    Lithium bismuth borate glasses containing mixed transition metals having composition 7CoO·23Li2O·20Bi2O3·50B2O3 (CLBB), 7V2O5·23Li2O·20Bi2O3·50B2O3 (VLBB) and x(2CoO·V2O5)·(30 - x)Li2O·20Bi2O3·50B2O3 (x = 0.0 (LBB) and x = 2.0, 5.0, 7.0, 10.0 mol% (CVLBB1-4)) are synthesized via melt quench route. The synthesized compositions are investigated for their physical properties using density (D) and molar volume (Vm), thermal properties by analyzing DSC/TG thermo-graphs, structural properties using IR absorption spectra in the mid-IR range and optical properties using UV-Vis-NIR spectroscopy. The Electron Paramagnetic Resonance (EPR) spectra of vanadyl and cobalt ion have been analyzed to study compositional effects on spin-Hamiltonian parameters. The non linear variations in physical properties depict a strong structural influence of Co/V- oxides on the glassy matrix. The compositional variations in characteristic temperatures (glass transition temperature Tg, glass crystallization temperature Tp and glass melting temperature Tm) reveals that Tg for glass samples CLBB is relatively less than that of pure lithium bismuth borate (LBB) glass sample wherein Tg for sample VLBB is higher than that of LBB. The increase in Tg (as compared with LBB) with an enhanced substitution of mixed transition metal oxides (2CoO·V2O5) shows a progressive structure modification of bismuth borate matrix. These predictions are very well corroborated by corresponding compositional trends of Tp and Tm. FTIR studies reveal that Co2+& VO2+ ions lead to structural rearrangements through the conversion of three-coordinated boron into four coordinated boron and thereby reducing number of non-bridging oxygen atoms. Bismuth is found to exist in [BiO6] octahedral units only, whereas boroxol rings are not present in the glass network. The theoretical values of optical basicity (Λth) and corresponding oxide ion polarizability (αo2-) have also been calculated to investigate oxygen covalency of glass matrix. Trends in both these parameters suggested an increase in ionic bonding on substitution of divalent transition metal cations causing a more bonding compaction in glass structure. The UV-Vis-NIR spectra suggest that cobalt ions exist as Co2+ states in octahedral coordination in glass network. Inter-electronic repulsion parameter and crystal field splitting energy were evaluated to understand the site symmetry around Co2+-ion in glass. X-band EPR spectra suggest that vanadium ions (V4+) exists as VO2+-ions in octahedral coordination with tetragonal compression. Spin Hamiltonian parameters g-values and A-values of VO2+ ions in glass were calculated. For sample CLBB two resonance lines in EPR spectrum attribute to octahedral symmetry around Co2+-ions were observed.

  16. Mechanism of lumen gain with a novel rotational aspiration atherectomy system for peripheral arterial disease: examination by intravascular ultrasound.

    PubMed

    Hassan, Ali H M; Ako, Junya; Waseda, Katsuhisa; Honda, Yasuhiro; Zeller, Thomas; Leon, Martin B; Fitzgerald, Peter J

    2010-01-01

    The purpose of this study was to evaluate the mechanism of luminal gain with a novel atheroablation system (Pathway PV) for the treatment of peripheral artery disease using intravascular ultrasound (IVUS). The atherectomy system is a rotational atherectomy device, which employs expandable rotating blades with ports that allow flushing and aspiration of the plaque material or thrombus. In this first-in-man clinical study, IVUS analysis was available in 6 patients with lower limb ischemia treated with this device. The treatment results were assessed using IVUS at pre and post atherectomy. Lumen beyond burr size (LBB) was defined as lumen gain divided by the estimated burr area determined by the burr-size. IVUS analysis was available in six patients (superficial femoral artery n=3, popliteal artery n=2, posterior tibial artery n=1). Atheroablation achieved a significant increase in lumen area (LA) (preintervention 3.9+/-0.4, postatheroablation 8.0+/-1.7 mm(2), P<.05), and significant reduction in plaque area (27.5+/-4.0, 23.7+/-3.1 mm(2), P=.001), while there was no change in the vessel area (31.3+/-4.2, 32.1+/-2.8 mm(2), P=.4). LBB was 57.4+/-51.3%. This novel rotational aspiration atherectomy device achieved significant luminal gain by debulking in the absence of vessel stretching. The LA was greater than burr-sized lumen expectancy at cross-sections along the treated segments, suggesting a complimentary role of aspiration in luminal gain in atherosclerotic peripheral artery lesions.

  17. Simulating squeeze flows in multiaxial laminates using an improved TIF model

    NASA Astrophysics Data System (ADS)

    Ibañez, R.; Abisset-Chavanne, Emmanuelle; Chinesta, Francisco

    2017-10-01

    Thermoplastic composites are widely considered in structural parts. In this paper attention is paid to squeeze flow of continuous fiber laminates. In the case of unidirectional prepregs, the ply constitutive equation is modeled as a transversally isotropic fluid, that must satisfy both the fiber inextensibility as well as the fluid incompressibility. When laminate is squeezed the flow kinematics exhibits a complex dependency along the laminate thickness requiring a detailed velocity description through the thickness. In a former work the solution making use of an in-plane-out-of-plane separated representation within the PGD - Poper Generalized Decomposition - framework was successfully accomplished when both kinematic constraints (inextensibility and in-compressibility) were introduced using a penalty formulation for circumventing the LBB constraints. However, such a formulation makes difficult the calculation on fiber tractions and compression forces, the last required in rheological characterizations. In this paper the former penalty formulation is substituted by a mixed formulation that makes use of two Lagrange multipliers, while addressing the LBB stability conditions within the separated representation framework, questions never until now addressed.

  18. Proteomes of Lactobacillus delbrueckii subsp. bulgaricus LBB.B5 Incubated in Milk at Optimal and Low Temperatures

    PubMed Central

    Yin, Xiaochen; Salemi, Michelle R.; Phinney, Brett S.; Gotcheva, Velitchka; Angelov, Angel

    2017-01-01

    ABSTRACT We identified the proteins synthesized by Lactobacillus delbrueckii subsp. bulgaricus strain LBB.B5 in laboratory culture medium (MRS) at 37°C and milk at 37 and 4°C. Cell-associated proteins were measured by gel-free, shotgun proteomics using high-performance liquid chromatography coupled with tandem mass spectrophotometry. A total of 635 proteins were recovered from all cultures, among which 72 proteins were milk associated (unique or significantly more abundant in milk). LBB.B5 responded to milk by increasing the production of proteins required for purine biosynthesis, carbohydrate metabolism (LacZ and ManM), energy metabolism (TpiA, PgK, Eno, SdhA, and GapN), amino acid synthesis (MetE, CysK, LBU0412, and AspC) and transport (GlnM and GlnP), and stress response (Trx, MsrA, MecA, and SmpB). The requirement for purines was confirmed by the significantly improved cell yields of L. delbrueckii subsp. bulgaricus when incubated in milk supplemented with adenine and guanine. The L. delbrueckii subsp. bulgaricus-expressed proteome in milk changed upon incubation at 4°C for 5 days and included increased levels of 17 proteins, several of which confer functions in stress tolerance (AddB, UvrC, RecA, and DnaJ). However, even with the activation of stress responses in either milk or MRS, L. delbrueckii subsp. bulgaricus did not survive passage through the murine digestive tract. These findings inform efforts to understand how L. delbrueckii subsp. bulgaricus is adapted to the dairy environment and its implications for its health-benefiting properties in the human digestive tract. IMPORTANCE Lactobacillus delbrueckii subsp. bulgaricus has a long history of use in yogurt production. Although commonly cocultured with Streptococcus salivarius subsp. thermophilus in milk, fundamental knowledge of the adaptive responses of L. delbrueckii subsp. bulgaricus to the dairy environment and the consequences of those responses on the use of L. delbrueckii subsp. bulgaricus as a probiotic remain to be elucidated. In this study, we identified proteins of L. delbrueckii subsp. bulgaricus LBB.B5 that are synthesized in higher quantities in milk at growth-conducive and non-growth-conductive (refrigeration) temperatures compared to laboratory culture medium and further examined whether those L. delbrueckii subsp. bulgaricus cultures were affected differently in their capacity to survive transit through the murine digestive tract. This work provides novel insight into how a major, food-adapted microbe responds to its primary habitat. Such knowledge can be applied to improve starter culture and yogurt production and to elucidate matrix effects on probiotic performance. PMID:28951887

  19. Proteomes of Lactobacillus delbrueckii subsp. bulgaricus LBB.B5 Incubated in Milk at Optimal and Low Temperatures.

    PubMed

    Yin, Xiaochen; Salemi, Michelle R; Phinney, Brett S; Gotcheva, Velitchka; Angelov, Angel; Marco, Maria L

    2017-01-01

    We identified the proteins synthesized by Lactobacillus delbrueckii subsp. bulgaricus strain LBB.B5 in laboratory culture medium (MRS) at 37°C and milk at 37 and 4°C. Cell-associated proteins were measured by gel-free, shotgun proteomics using high-performance liquid chromatography coupled with tandem mass spectrophotometry. A total of 635 proteins were recovered from all cultures, among which 72 proteins were milk associated (unique or significantly more abundant in milk). LBB.B5 responded to milk by increasing the production of proteins required for purine biosynthesis, carbohydrate metabolism (LacZ and ManM), energy metabolism (TpiA, PgK, Eno, SdhA, and GapN), amino acid synthesis (MetE, CysK, LBU0412, and AspC) and transport (GlnM and GlnP), and stress response (Trx, MsrA, MecA, and SmpB). The requirement for purines was confirmed by the significantly improved cell yields of L. delbrueckii subsp. bulgaricus when incubated in milk supplemented with adenine and guanine. The L. delbrueckii subsp. bulgaricus -expressed proteome in milk changed upon incubation at 4°C for 5 days and included increased levels of 17 proteins, several of which confer functions in stress tolerance (AddB, UvrC, RecA, and DnaJ). However, even with the activation of stress responses in either milk or MRS, L. delbrueckii subsp. bulgaricus did not survive passage through the murine digestive tract. These findings inform efforts to understand how L. delbrueckii subsp. bulgaricus is adapted to the dairy environment and its implications for its health-benefiting properties in the human digestive tract. IMPORTANCE Lactobacillus delbrueckii subsp. bulgaricus has a long history of use in yogurt production. Although commonly cocultured with Streptococcus salivarius subsp. thermophilus in milk, fundamental knowledge of the adaptive responses of L. delbrueckii subsp. bulgaricus to the dairy environment and the consequences of those responses on the use of L. delbrueckii subsp. bulgaricus as a probiotic remain to be elucidated. In this study, we identified proteins of L. delbrueckii subsp. bulgaricus LBB.B5 that are synthesized in higher quantities in milk at growth-conducive and non-growth-conductive (refrigeration) temperatures compared to laboratory culture medium and further examined whether those L. delbrueckii subsp. bulgaricus cultures were affected differently in their capacity to survive transit through the murine digestive tract. This work provides novel insight into how a major, food-adapted microbe responds to its primary habitat. Such knowledge can be applied to improve starter culture and yogurt production and to elucidate matrix effects on probiotic performance.

  20. A new sum parameter to estimate the bioconcentration and baseline-toxicity of hydrophobic compounds in river water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loon, W.M.G.M. van; Hermens, J.L.M.

    1994-12-31

    A large part of all aquatic pollutants can be classified as narcosis-type (baseline toxicity) chemicals. Many chemicals contribute to a joint baseline aquatic toxicity even at trace concentrations. A novel surrogate parameter, which simulated bioconcentration of hydrophobic substances from water and estimates internal molar concentrations, has been explored by Verhaar et al.. These estimated biological concentrations can be used to predict narcosis-type toxic effects, using the Lethal Body Burden (LBB) concept. The authors applied this toxicological-analytical concept to river water, and some recent technological developments and field results are pointed out. The simulation of bioconcentration is performed by extracting watermore » samples with empore{trademark} disks. The authors developed two extraction procedures; i.e., laboratory extraction and field extraction. Molar concentrations measurements are performed using vapor pressure osmometry, GC-FID and GC-MS. Results on the molar concentrations of hydrophobic compounds which can be bioaccumulated from several Dutch river systems will be presented.« less

  1. 20 CFR 10.7 - What forms are needed to process claims under the FECA?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Form No. Title (1) CA-1 Federal Employee's Notice of Traumatic Injury and Claim for Continuation of Pay... Traumatic Injury or Occupational Disease (8) CA-7a Time Analysis Form (9) CA-7b Leave Buy Back (LBB... claims under the FECA? (a) Notice of injury, claims and certain specified reports shall be made on forms...

  2. 20 CFR 10.7 - What forms are needed to process claims under the FECA?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... Form No. Title (1) CA-1 Federal Employee's Notice of Traumatic Injury and Claim for Continuation of Pay... Traumatic Injury or Occupational Disease (8) CA-7a Time Analysis Form (9) CA-7b Leave Buy Back (LBB... claims under the FECA? (a) Notice of injury, claims and certain specified reports shall be made on forms...

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turbat, A.; Deschanels, H.; Sperandio, M.

    The leak before break (LBB) concept was not used at the design level for SUPERPHENIX (SPX), but different studies have been performed or are in progress concerning different components : Main Vessel (MV), pipings. These studies were undertaken to improve the defense in depth, an approach used in all French reactors. In a first study, the LBB approach has been applied to the MV of SPX plant to verify the absence of risk as regards the core supporting function and to help in the definition of in-service inspection (ISI) program. Defining a reference semi-elliptic defect located in the welds ofmore » the structure, it is verified that the crack growth is limited and that the end-of-life defect is smaller than the critical one. Then it is shown that the hoop welds (those which are the most important for safety) located between the roof and the triple point verify the leak-before-break criteria. However, generally speaking, the low level of membrane primary stresses which is favorable for the integrity of the vessel makes the application of the leak-before-break concept more difficult due to small crack opening areas. Finally, the extension of the methodology to the secondary pipings of SPX incorporating recent European works of DCRC is briefly presented.« less

  4. Research Design for the Chief Joseph Dam Cultural Resources Project.

    DTIC Science & Technology

    1984-01-01

    peoples of Northeastern Washington. Written as a masters thesis ( UW 1933), this study of the Nespelem and the Sanpoll tribes, who lived in and around...Methods of Soil Analysis. American Society of Agronomy, Madison . Bonnichsen, R. and R.T. Will 1980 Cultural modification of bone: The experimental...Name 32 - 35 Skeletal Element Key TH0C Thoracic Centrum (continued) THEC Thoracic Zygapophsis LbbLrLVLUMB Lumbar Vertebra Indet LUMM Lumbar Vertebra I

  5. Experiences with leak rate calculations methods for LBB application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grebner, H.; Kastner, W.; Hoefler, A.

    1997-04-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.

  6. Examination of Growth Hormone (GH) Gene Polymorphism and its Association with Body Weight and Selected Body Dimensions in Ducks.

    PubMed

    Mazurowski, Artur; Frieske, Anna; Kokoszynski, Dariusz; Mroczkowski, Sławomir; Bernacki, Zenon; Wilkanowska, Anna

    2015-01-01

    The main objective of the study was to assess the polymorphism in intron 2 of the GH gene and its association with some morphological traits (body weight--BW, length of trunk with neck--LTN, length of trunk--LT, chest girth--CG, length of breast bone--LBB, length of shank--LS). Polymorphism in intron 2 of the GH gene was evaluated for four duck populations (Pekin ducks AF51, Muscovy ducks from a CK and CRAMMLCFF mother and Mulard ducks). Genetic polymorphism was determined with the PCR-RFLP method using the BsmFI restriction enzyme. In the studied duck sample two alleles (GH(C) and GH(T)) and three genotypes (GH/TT, GH/CT, GH/CC) were found at locus GH/BsmFI. In both groups of Muscovies and in Mulards the dominant allele was GH(T). On the contrary in Pekin ducks AF51, the frequency of both alleles was found to be similar. The most frequent genotype in the examined ducks was GH/TT. In Pekin ducks AF51 three genotypes were observed, while in Mulard ducks and in male Muscovy ducks from a mother marked as CK, two genotypes (GH/TT and GH/CT) were identified. Muscovy duck females from a CK mother and all males and females of Muscovy duck from a CRAMMLCFF mother were monomorphic with only the GH/TTgenotype detected. The results showed that males of Pekin duck AF51 with the GH/TT genotype were characterized by higher (P < 0.01) BW value than those with the GH/CC and GH/CTgenotype. In females of Pekin ducks AF51, this same trend was observed; individuals with GH/TT genotype were superior (P < 0.05 and P < 0.01) to birds with two other detected genotypes in respect to BW, CG, LBB and LS. In the case of Mulards, ducks with the GH/TT genotype were distinguished by higher values of all evaluated traits compared to ducks with GH/CT and GH/CC genotypes, however most of the recorded differences were not significant. The only trait markedly impacted (P < 0.05) by the polymorphism of the GH gene intron 2 was the LS value in males.

  7. Effect of heat-assisted pulsed electric fields and bacteriophage on enterohemorrhagic Escherichia coli O157:H7.

    PubMed

    Walkling-Ribeiro, Markus; Anany, Hany; Griffiths, Mansel W

    2015-01-01

    Pulsed electric fields (PEF), heat-assisted PEF (H-PEF), and virulent bacteriophage (VP) are non-thermal techniques for pathogen inactivation in liquids that were investigated individually, and in combination (PEF/VP, H-PEF/VP) to control enterohemorrhagic Escherichia coli (EHEC) O157:H7 in Luria-Bertani broth (LBB) and Ringer's solution (RS). Treated cells were subsequently incubated at refrigeration (4°C) and temperature-abuse conditions (12°C) for 5 days. When EHEC cells grown in LBB were subjected to non-thermal processing and subsequently stored at 12°C for 5 days, reductions in count of between 0.1 and 0.6 log cycles were observed and following storage at 4°C the decrease in counts varied between 0.2 and 1.1 log10 . For bacteria cells suspended in RS values ranged from 0.1 to ≥3.9 log cycles at both storage temperatures. The most effective treatments were H-PEF and H-PEF/VP, both producing a >3.4 log cycle reduction of cells suspended in non-nutrient RS. Analysis of EHEC recovery on selective and non-selective media indicated no occurrence of sub-lethal damage for VP, PEF/VP, and H-PEF/VP-treated cells. The findings indicate that combining PEF and lytic phage may represent a suitable alternative to conventional fluid decontamination following further process optimization. © 2014 American Institute of Chemical Engineers.

  8. Optical and Physical Investigations of Lanthanum Bismuth Borate glasses doped with Ho2O3

    NASA Astrophysics Data System (ADS)

    Ramesh, P.; Jagannath, G.; Eraiah, B.; Kokila, M. K.

    2018-02-01

    Holmium doped 10La2O3-15Bi2O3-(75-x) B2O3 (Ho3+: LBB) glasses have been prepared by melt quench technique and the impact of holmium ions concentration on optical and physical properties of present glasses have been examined. Ho3+ dependent density, molar volume, refractive index, rare earth ion concentration, polaron radius, inter ionic distance, field strength and energy band gap are calculated and tabulated. Amorphous nature of the all glasses has been confirmed by XRD patterns. The room temperature (RT) Uv-Vis absorption spectrum doped with 1 mol% of Ho2O3 exhibit eight prominent bands centred at 895, 641, 537, 486, 472, 467, 451 and 416 due to transition between ground state to various excited states. The results show that, the density is increases and molar volume of the glasses is decreases with an increase in Ho2O3 concentration and consequently generate more non-bridging oxygen (NBOs) in the glass matrix. The Urbach energy is increases with holmium concentration which exemplifies the degree of disorder present in the LBB glasses. The considerable increase in field strength observed in present glasses is attributed to occurrence of strong bridge between Ho3+ and B- ions and this strong bridge is possibly due to the displacement between Ho3+ and oxygen atoms which are generated from the conversion BO3-BO4 units.

  9. Crack instability analysis methods for leak-before-break program in piping systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mattar Neto, M.; Maneschy, E.; Nobrega, P.G.B. da

    1995-11-01

    The instability evaluation of cracks in piping systems is a step that is considered when a high-energy line is investigated in a leak-before-break (LBB) program. Different approaches have been used to assess stability of cracks: (a) local flow stress (LFS); (b) limit load (LL); (c) elastic-plastic fracture mechanics (EPFM) as J-integral versus tearing modulus (J-T) analysis. The first two methods are used for high ductile materials, when it is assumed that remaining ligament of the cracked pipe section becomes fully plastic prior to crack extension. EPFM is considered for low ductile piping when the material reaches unstable ductile tearing priormore » to plastic collapse in the net section. In this paper the LFS, LL and EPFM J-T methodologies were applied to calculate failure loads in circumferential through-wall cracked pipes with different materials, geometries and loads. It presents a comparison among the results obtained from the above three formulations and also compares them with experimental data available in the literature.« less

  10. Effect of Combined Loading Due to Bending and Internal Pressure on Pipe Flaw Evaluation Criteria

    NASA Astrophysics Data System (ADS)

    Miura, Naoki; Sakai, Shinsuke

    Considering a rule for the rationalization of maintenance of Light Water Reactor piping, reliable flaw evaluation criteria are essential for determining how a detected flaw will be detrimental to continuous plant operation. Ductile fracture is one of the dominant failure modes that must be considered for carbon steel piping and can be analyzed by elastic-plastic fracture mechanics. Some analytical efforts have provided various flaw evaluation criteria using load correction factors, such as the Z-factors in the JSME codes on fitness-for-service for nuclear power plants and the section XI of the ASME boiler and pressure vessel code. The present Z-factors were conventionally determined, taking conservativity and simplicity into account; however, the effect of internal pressure, which is an important factor under actual plant conditions, was not adequately considered. Recently, a J-estimation scheme, LBB.ENGC for the ductile fracture analysis of circumferentially through-wall-cracked pipes subjected to combined loading was developed for more accurate prediction under more realistic conditions. This method explicitly incorporates the contributions of both bending and tension due to internal pressure by means of a scheme that is compatible with an arbitrary combined-loading history. In this study, the effect of internal pressure on the flaw evaluation criteria was investigated using the new J-estimation scheme. The Z-factor obtained in this study was compared with the presently used Z-factors, and the predictability of the current flaw evaluation criteria was quantitatively evaluated in consideration of the internal pressure.

  11. Enzyme Mini-Test for Field Identification of Leishmania Isolates from U.S. Military Personnel.

    DTIC Science & Technology

    1986-05-15

    Panama Dominques L2 539 NWC LBP Man - Panama Carillo 530 NWC LBP Man - Panama Schoonmaker 063 NWC LBG Man - Peru Terborgh/Muco 294 NWC LBB Man - Brazil...NWC LMA-G Man - Panama Castro 140 NWC LMM-P Man - Peru UTA 381 NWC LMM-P Man - Panama Peters 453 NWC LMM-P Man - Dominican Republic - 457 NWC LMM-P...LV24 547 OWC LMJ Man R. Beach Kenya LRC-L137 551 OWC LMJ Rodent R. Beach Kenya NLB095 552 OWC LMJ Sandfly R. Beach Kenya NLBI44 558 OWC LMJ Man

  12. Effects of weld residual stresses on crack-opening area analysis of pipes for LBB applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, P.; Rahman, S.; Wilkowski, G.

    1997-04-01

    This paper summarizes four different studies undertaken to evaluate the effects of weld residual stresses on the crack-opening behavior of a circumferential through-wall crack in the center of a girth weld. The effect of weld residual stress on the crack-opening-area and leak-rate analyses of a pipe is not well understood. There are no simple analyses to account for these effects, and, therefore, they are frequently neglected. The four studies involved the following efforts: (1) Full-field thermoplastic finite element residual stress analyses of a crack in the center of a girth weld, (2) A comparison of the crack-opening displacements from amore » full-field thermoplastic residual stress analysis with a crack-face pressure elastic stress analysis to determine the residual stress effects on the crack-opening displacement, (3) The effects of hydrostatic testing on the residual stresses and the resulting crack-opening displacement, and (4) The effect of residual stresses on crack-opening displacement with different normal operating stresses.« less

  13. Culturable Rhodobacter and Shewanella species are abundant in estuarine turbidity maxima of the Columbia River

    PubMed Central

    Bräuer, S. L.; Adams, C.; Kranzler, K.; Murphy, D.; Xu, M.; Zuber, P.; Simon, H. M.; Baptista, A. M.; Tebo, B. M.

    2017-01-01

    Summary Measurements of dissolved, ascorbate-reducible and total Mn by ICP-OES revealed significantly higher concentrations during estuarine turbidity maxima (ETM) events, compared with non-events in the Columbia River. Most probable number (MPN) counts of Mn-oxidizing or Mn-reducing heterotrophs were not statistically different from that of other heterotrophs (103–104 cells ml−1) when grown in defined media, but counts of Mn oxidizers were significantly lower in nutrient-rich medium (13 cells ml−1). MPN counts of Mn oxidizers were also significantly lower on Mn(III)-pyrophosphate and glycerol (21 cells ml−1). Large numbers of Rhodobacter spp. were cultured from dilutions of 10−2 to 10−5, and many of these were capable of Mn(III) oxidation. Up to c. 30% of the colonies tested LBB positive, and all 77 of the successfully sequenced LBB positive colonies (of varying morphology) yielded sequences related to Rhodobacter spp. qPCR indicated that a cluster of Rhodobacter isolates and closely related strains (95–99% identity) represented approximately 1–3% of the total Bacteria, consistent with clone library results. Copy numbers of SSU rRNA genes for either Rhodobacter spp. or Bacteria were four to eightfold greater during ETM events compared with non-events. Strains of a Shewanella sp. were retrieved from the highest dilutions (10−5) of Mn reducers, and were also capable of Mn oxidation. The SSU rRNA gene sequences from these strains shared a high identity score (98%) with sequences obtained in clone libraries. Our results support previous findings that ETMs are zones with high microbial activity. Results indicated that Shewanella and Rhodobacter species were present in environmentally relevant concentrations, and further demonstrated that a large proportion of culturable bacteria, including Shewanella and Rhodobacter spp., were capable of Mn cycling in vitro. PMID:20977571

  14. On Raviart-Thomas and VMS formulations for flow in heterogeneous materials.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, Daniel Zack

    It is well known that the continuous Galerkin method (in its standard form) is not locally conservative, yet many stabilized methods are constructed by augmenting the standard Galerkin weak form. In particular, the Variational Multiscale (VMS) method has achieved popularity for combating numerical instabilities that arise for mixed formulations that do not otherwise satisfy the LBB condition. Among alternative methods that satisfy local and global conservation, many employ Raviart-Thomas function spaces. The lowest order Raviart-Thomas finite element formulation (RT0) consists of evaluating fluxes over the midpoint of element edges and constant pressures within the element. Although the RT0 element posesmore » many advantages, it has only been shown viable for triangular or tetrahedral elements (quadrilateral variants of this method do not pass the patch test). In the context of heterogenous materials, both of these methods have been used to model the mixed form of the Darcy equation. This work aims, in a comparative fashion, to evaluate the strengths and weaknesses of either approach for modeling Darcy flow for problems with highly varying material permeabilities and predominantly open flow boundary conditions. Such problems include carbon sequestration and enhanced oil recovery simulations for which the far-field boundary is typically described with some type of pressure boundary condition. We intend to show the degree to which the VMS formulation violates local mass conservation for these types of problems and compare the performance of the VMS and RT0 methods at boundaries between disparate permeabilities.« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samohyl, P.

    The application of the LBB requires also fatigue flaw growth assessment. This analysis was performed for PWR nuclear power plants types VVER 440/230, VVER 440/213c, VVER 1000/320. Respecting that these NPP`s were designed according to Russian codes that differ from US codes it was needed to compare these approaches. Comparison with our experimental data was accomplished, too. Margins of applicability of the US methods and their modifications for the materials used for construction of Czech and Slovak NPP`s are shown. Computer code accomplishing the analysis according to described method is presented. Some measurement and calculations show that thermal stratifications inmore » horizontal pipelines can lead to additive loads that are not negligible and can be dangerous. An attempt to include these loads induced by steady-state stratification was made.« less

  16. N-16 monitors: Almaraz NPP experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adrada, J.

    1997-02-01

    Almaraz Nuclear Power Plant has installed N-16 monitors - one per steam generator - to control the leakage rate through the steam generator tubes after the application of leak before break (LBB) criteria for the top tube sheet (TTS). After several years of operation with the N-16 monitors, Almaraz NPP experience may be summarized as follows: N-16 monitors are very useful to follow the steam generator leak rate trend and to detect an incipient tube rupture; but they do not provide an exact absolute leak rate value, mainly when there are small leaks. The evolution of the measured N-16 leakmore » rates varies along the fuel cycle, with the same trend for the 3 steam generators. This behaviour is associated with the primary water chemistry evolution along the cycle.« less

  17. A mimetic finite difference method for the Stokes problem with elected edge bubbles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lipnikov, K; Berirao, L

    2009-01-01

    A new mimetic finite difference method for the Stokes problem is proposed and analyzed. The unstable P{sub 1}-P{sub 0} discretization is stabilized by adding a small number of bubble functions to selected mesh edges. A simple strategy for selecting such edges is proposed and verified with numerical experiments. The discretizations schemes for Stokes and Navier-Stokes equations must satisfy the celebrated inf-sup (or the LBB) stability condition. The stability condition implies a balance between discrete spaces for velocity and pressure. In finite elements, this balance is frequently achieved by adding bubble functions to the velocity space. The goal of this articlemore » is to show that the stabilizing edge bubble functions can be added only to a small set of mesh edges. This results in a smaller algebraic system and potentially in a faster calculations. We employ the mimetic finite difference (MFD) discretization technique that works for general polyhedral meshes and can accomodate non-uniform distribution of stabilizing bubbles.« less

  18. ORNL Pre-test Analyses of A Large-scale Experiment in STYLE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Paul T; Yin, Shengjun; Klasky, Hilda B

    Oak Ridge National Laboratory (ORNL) is conducting a series of numerical analyses to simulate a large scale mock-up experiment planned within the European Network for Structural Integrity for Lifetime Management non-RPV Components (STYLE). STYLE is a European cooperative effort to assess the structural integrity of (non-reactor pressure vessel) reactor coolant pressure boundary components relevant to ageing and life-time management and to integrate the knowledge created in the project into mainstream nuclear industry assessment codes. ORNL contributes work-in-kind support to STYLE Work Package 2 (Numerical Analysis/Advanced Tools) and Work Package 3 (Engineering Assessment Methods/LBB Analyses). This paper summarizes the current statusmore » of ORNL analyses of the STYLE Mock-Up3 large-scale experiment to simulate and evaluate crack growth in a cladded ferritic pipe. The analyses are being performed in two parts. In the first part, advanced fracture mechanics models are being developed and performed to evaluate several experiment designs taking into account the capabilities of the test facility while satisfying the test objectives. Then these advanced fracture mechanics models will be utilized to simulate the crack growth in the large scale mock-up test. For the second part, the recently developed ORNL SIAM-PFM open-source, cross-platform, probabilistic computational tool will be used to generate an alternative assessment for comparison with the advanced fracture mechanics model results. The SIAM-PFM probabilistic analysis of the Mock-Up3 experiment will utilize fracture modules that are installed into a general probabilistic framework. The probabilistic results of the Mock-Up3 experiment obtained from SIAM-PFM will be compared to those results generated using the deterministic 3D nonlinear finite-element modeling approach. The objective of the probabilistic analysis is to provide uncertainty bounds that will assist in assessing the more detailed 3D finite-element solutions and to also assess the level of confidence that can be placed in the best-estimate finiteelement solutions.« less

  19. Schistosomes infection rate in relation to environmental factors in school children.

    PubMed

    Raja'a, Y A; Assiragi, H M; Abu-Luhom, A A; Mohammed, A B; Albahr, M H; Ashaddadi, M A; Al Muflihi, A N

    2000-07-01

    An epidemiological comparative survey aimed at determination of prevalence and focal distribution of Schistosomes infection and intestinal parasites to provide a reference for evaluating the need for community intervention. All children of 14th October Primary School were involved. The children were from 7 villages that lie on the Assahul valley of lbb governorates in Yemen. The total number was 230 with (82%) boys and (18%) girls. Their age was between 5-18 years with a mean of 10.24 +/- 2.6 years. Millipore and modified Kato techniques were adopted to quantify urinary and intestinal Schistosomes eggs. Other ova, larvae, cysts were recorded whenever seen. It was revealed that there was a Schistosomes infection rate of 37%. The mansoni prevalence was 35%, hematobia was 5% and mixed infections were 3%. Light infection was classified among 17% of all children; moderate infection among 18% and no intense mansoni infection was determined. Whereas in the case of hematobia species, 2% were intense and 3% were light. Intensity in all children was 5% eggs/g feces in case of intestinal bilharzia and 1% egg/10 ml urine in case of urinary. With regard to the prevalence of any soil-transmitted parasites, it was found to be 69% (Ascariosis 68%, Trichuriosis 10%). Double infection was found in 10%. Hookworm eggs were not seen. Infection rates with other parasites were as follows: Giardiosis 18%, Amoebiosis 14%, ova of Hymenolepes nana were seen in 13%, Taeniosis affected 13% and E. Vermicularis 1%. Bivariate analysis revealed significant associations between Schistosomes infection with residence near the valley, male sex and frequent water contact activities. No significant association was found with the age of the child, parents' education, availability of latrine or household standpipe water. In conclusion, schistosomosis was moderate, whereas soil transmitted helminthosis were intense.

  20. Minimization principles for the coupled problem of Darcy-Biot-type fluid transport in porous media linked to phase field modeling of fracture

    NASA Astrophysics Data System (ADS)

    Miehe, Christian; Mauthe, Steffen; Teichtmeister, Stephan

    2015-09-01

    This work develops new minimization and saddle point principles for the coupled problem of Darcy-Biot-type fluid transport in porous media at fracture. It shows that the quasi-static problem of elastically deforming, fluid-saturated porous media is related to a minimization principle for the evolution problem. This two-field principle determines the rate of deformation and the fluid mass flux vector. It provides a canonically compact model structure, where the stress equilibrium and the inverse Darcy's law appear as the Euler equations of a variational statement. A Legendre transformation of the dissipation potential relates the minimization principle to a characteristic three field saddle point principle, whose Euler equations determine the evolutions of deformation and fluid content as well as Darcy's law. A further geometric assumption results in modified variational principles for a simplified theory, where the fluid content is linked to the volumetric deformation. The existence of these variational principles underlines inherent symmetries of Darcy-Biot theories of porous media. This can be exploited in the numerical implementation by the construction of time- and space-discrete variational principles, which fully determine the update problems of typical time stepping schemes. Here, the proposed minimization principle for the coupled problem is advantageous with regard to a new unconstrained stable finite element design, while space discretizations of the saddle point principles are constrained by the LBB condition. The variational principles developed provide the most fundamental approach to the discretization of nonlinear fluid-structure interactions, showing symmetric systems in algebraic update procedures. They also provide an excellent starting point for extensions towards more complex problems. This is demonstrated by developing a minimization principle for a phase field description of fracture in fluid-saturated porous media. It is designed for an incorporation of alternative crack driving forces, such as a convenient criterion in terms of the effective stress. The proposed setting provides a modeling framework for the analysis of complex problems such as hydraulic fracture. This is demonstrated by a spectrum of model simulations.

  1. An interspecies correlation model to predict acute dermal toxicity of plant protection products to terrestrial life stages of amphibians using fish acute toxicity and bioconcentration data.

    PubMed

    Weltje, Lennart; Janz, Philipp; Sowig, Peter

    2017-12-01

    This paper presents a model to predict acute dermal toxicity of plant protection products (PPPs) to terrestrial amphibian life stages from (regulatory) fish data. By combining existing concepts, including interspecies correlation estimation (ICE), allometric relations, lethal body burden (LBB) and bioconcentration modelling, an equation was derived that predicts the amphibian median lethal dermal dose (LD 50 ) from standard acute toxicity values (96-h LC 50 ) for fish and bioconcentration factors (BCF) in fish. Where possible, fish BCF values were corrected to 5% lipid, and to parent compound. Then, BCF values were adjusted to an exposure duration of 96 h, in case steady state took longer to be achieved. The derived correlation equation is based on 32 LD 50 values from acute dermal toxicity experiments with 15 different species of anuran amphibians, comprising 15 different PPPs. The developed ICE model can be used in a screening approach to estimate the acute risk to amphibian terrestrial life stages from dermal exposures to PPPs with organic active substances. This has the potential to reduce unnecessary testing of vertebrates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. 48 CFR 45.202 - Evaluation procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Evaluation procedures. 45... MANAGEMENT GOVERNMENT PROPERTY Solicitation and Evaluation Procedures 45.202 Evaluation procedures. (a) The... evaluation purposes only, a rental equivalent evaluation factor. (b) The contracting officer shall ensure the...

  3. 29 CFR 1956.22 - Procedures for evaluation and monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Procedures for evaluation and monitoring. 1956.22 Section 1956.22 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION..., Change, Evaluation and Withdrawal of Approval Procedures § 1956.22 Procedures for evaluation and...

  4. 34 CFR 300.304 - Evaluation procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Educational Placements Evaluations and Reevaluations § 300.304 Evaluation procedures. (a) Notice. The public... conducting the evaluation, the public agency must— (1) Use a variety of assessment tools and strategies to... evaluation procedures. Each public agency must ensure that— (1) Assessments and other evaluation materials...

  5. Subjective Well-being and Family Functioning among Adolescents Left Behind by Migrating Parents in Jiangxi Province, China.

    PubMed

    Zhou, Jia; Hu, Fang; Wu, Jing; Zou, Zhi Yong; Wang, Yi Xin; Peng, Hua Can; Vermund, Sten H; Hu, Yi Fei; Ma, Ying Hua

    2018-05-01

    We sought to identify the differences between adolescents left behind in their home villages/towns (LBA) and non-left behind adolescents (NLB) on subjective well-being and family functioning due to parental migration in south China. We used a stratified cluster sampling method to recruit middle school students in a city experiencing population-emigration in Jiangxi Province in 2010. Participants included adolescents from families with: (1) one migrant parent, (2) both parents who migrated, or (3) non-left behind adolescents (i.e., no migrant parent). To determine predictors of subjective well-being, we used structural equation models. Adolescents left behind by both parents (LBB) were less likely to express life satisfaction (P = 0.038) in terms of their environments (P = 0.011) compared with NLB. A parent or parents who migrated predicts lower subjective well-being of adolescents (P = 0.051) and also lower academic performance. Being apart from their parents may affect family functioning negatively from an adolescent's viewpoint. Given the hundreds of millions of persons in China, many who are parents, migrating for work, there may be mental health challenges in some of the adolescents left behind. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  6. Evidence for the presence of restriction/modification systems in Lactobacillus delbrueckii.

    PubMed

    Suárez, Viviana; Zago, Miriam; Giraffa, Giorgio; Reinheimer, Jorge; Quiberoni, Andrea

    2009-11-01

    The bacteriophages Cb1/204 and Cb1/342 were obtained by induction from the commercial strain Lactobacillus delbrueckii subsp. lactis Cb1, and propagated on Lactobacillus delbrueckii subsp. lactis 204 (Lb.l 204) and Lactobacillus delbrueckii subsp. bulgaricus 342 (Lb.b 342), respectively. By cross sensitivity, it was possible to detect a delay in the lysis of Lb.l 204 with Cb1/342 phage, while the adsorption rate was high (99.5%). Modified and unmodified phages were isolated using phage Cb1/342 and strain Lb.l 204. The EOP (Efficiency of Plaquing) values for the four phages (Cb1/204, Cb1/342, Cb1/342modified and Cb1/342unmodified) suggested that an R/M system modified the original temperate phage, and the BglII-DNA restriction patterns of these phages might point out the presence of a Type II R/M system. Also, the existence of a Type I R/M system was demonstrated by PCR and nucleotide sequence, being the percentages of alignment homology with Type I R/M systems reported previously higher than 95%. In this study it was possible to demonstrate that the native phage resistant mechanisms and the occurrence of prophages in commercial host strains, contribute strongly to diversify the phage population in a factory environment.

  7. Structure of the dimeric RC–LH1–PufX complex from Rhodobaca bogoriensis investigated by electron microscopy

    PubMed Central

    Semchonok, Dmitry A.; Chauvin, Jean-Paul; Frese, Raoul N.; Jungas, Colette; Boekema, Egbert J.

    2012-01-01

    Electron microscopy and single-particle averaging were performed on isolated reaction centre (RC)—antenna complexes (RC–LH1–PufX complexes) of Rhodobaca bogoriensis strain LBB1, with the aim of establishing the LH1 antenna conformation, and, in particular, the structural role of the PufX protein. Projection maps of dimeric complexes were obtained at 13 Å resolution and show the positions of the 2 × 14 LH1 α- and β-subunits. This new dimeric complex displays two open, C-shaped LH1 aggregates of 13 αβ polypeptides partially surrounding the RCs plus two LH1 units forming the dimer interface in the centre. Between the interface and the two half rings are two openings on each side. Next to the openings, there are four additional densities present per dimer, considered to be occupied by four copies of PufX. The position of the RC in our model was verified by comparison with RC–LH1–PufX complexes in membranes. Our model differs from previously proposed configurations for Rhodobacter species in which the LH1 ribbon is continuous in the shape of an S, and the stoichiometry is of one PufX per RC. PMID:23148268

  8. 34 CFR 300.304 - Evaluation procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Placements Evaluations and Reevaluations § 300.304 Evaluation procedures. (a) Notice. The public agency must... evaluation, the public agency must— (1) Use a variety of assessment tools and strategies to gather relevant... procedures. Each public agency must ensure that— (1) Assessments and other evaluation materials used to...

  9. Substrate specificity characterization for eight putative nudix hydrolases. Evaluation of criteria for substrate identification within the Nudix family.

    PubMed

    Nguyen, Vi N; Park, Annsea; Xu, Anting; Srouji, John R; Brenner, Steven E; Kirsch, Jack F

    2016-12-01

    The nearly 50,000 known Nudix proteins have a diverse array of functions, of which the most extensively studied is the catalyzed hydrolysis of aberrant nucleotide triphosphates. The functions of 171 Nudix proteins have been characterized to some degree, although physiological relevance of the assayed activities has not always been conclusively demonstrated. We investigated substrate specificity for eight structurally characterized Nudix proteins, whose functions were unknown. These proteins were screened for hydrolase activity against a 74-compound library of known Nudix enzyme substrates. We found substrates for four enzymes with k cat /K m values >10,000 M -1  s -1 : Q92EH0_LISIN of Listeria innocua serovar 6a against ADP-ribose, Q5LBB1_BACFN of Bacillus fragilis against 5-Me-CTP, and Q0TTC5_CLOP1 and Q0TS82_CLOP1 of Clostridium perfringens against 8-oxo-dATP and 3'-dGTP, respectively. To ascertain whether these identified substrates were physiologically relevant, we surveyed all reported Nudix hydrolytic activities against NTPs. Twenty-two Nudix enzymes are reported to have activity against canonical NTPs. With a single exception, we find that the reported k cat /K m values exhibited against these canonical substrates are well under 10 5 M -1  s -1 . By contrast, several Nudix enzymes show much larger k cat /K m values (in the range of 10 5 to >10 7 M -1  s -1 ) against noncanonical NTPs. We therefore conclude that hydrolytic activities exhibited by these enzymes against canonical NTPs are not likely their physiological function, but rather the result of unavoidable collateral damage occasioned by the enzymes' inability to distinguish completely between similar substrate structures. Proteins 2016; 84:1810-1822. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. 22 CFR 96.100 - Procedures for evaluating applicants for temporary accreditation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Procedures and Standards Relating to Temporary Accreditation § 96.100 Procedures for evaluating applicants... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Procedures for evaluating applicants for... entity must: (1) Review the agency's written application and supporting documentation; and (2) Verify the...

  11. Major System Source Evaluation and Selection Procedures.

    DTIC Science & Technology

    1987-04-02

    A-RIBI I" MAJOR SYSTEM SOURCE EVALUATION AND SELECTION PROCEDURES / (U) BUSINESS MANAGEMENT RESEARCH ASSOCIATES INC ARLINGTON VA 02 APR 6? ORMC-5...BRMC-85-5142-1 0 I- MAJOR SYSTEM SOURCE EVALUATION AND SELECTION PROCEDURES o I Business Management Research Associates, Inc. 1911 Jefferson Davis...FORCE SOURCE EVALUATION AND SELECTI ON PROCEDURES Prepared by Business Management Research Associates, Inc., 1911 Jefferson Davis Highway, Arlington

  12. 29 CFR 1956.22 - Procedures for evaluation and monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Change, Evaluation and Withdrawal of Approval Procedures § 1956.22 Procedures for evaluation and... enforcement authority under section 18(e) of the Act is not relevant to Phase II and III monitoring under...

  13. A framework for assessing the adequacy and effectiveness of software development methodologies

    NASA Technical Reports Server (NTRS)

    Arthur, James D.; Nance, Richard E.

    1990-01-01

    Tools, techniques, environments, and methodologies dominate the software engineering literature, but relatively little research in the evaluation of methodologies is evident. This work reports an initial attempt to develop a procedural approach to evaluating software development methodologies. Prominent in this approach are: (1) an explication of the role of a methodology in the software development process; (2) the development of a procedure based on linkages among objectives, principles, and attributes; and (3) the establishment of a basis for reduction of the subjective nature of the evaluation through the introduction of properties. An application of the evaluation procedure to two Navy methodologies has provided consistent results that demonstrate the utility and versatility of the evaluation procedure. Current research efforts focus on the continued refinement of the evaluation procedure through the identification and integration of product quality indicators reflective of attribute presence, and the validation of metrics supporting the measure of those indicators. The consequent refinement of the evaluation procedure offers promise of a flexible approach that admits to change as the field of knowledge matures. In conclusion, the procedural approach presented in this paper represents a promising path toward the end goal of objectively evaluating software engineering methodologies.

  14. Evaluation of standardized sample collection, packaging, and ...

    EPA Pesticide Factsheets

    Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.

  15. A decision support system-based procedure for evaluation and monitoring of protected areas sustainability for the Mediterranean region

    NASA Astrophysics Data System (ADS)

    Pediaditi, K.; Buono, F.; Pompigna, F.; Bogliotti, C.; Nurlu, E.; Ladisa, G.; Petropoulos, G. P.

    2011-10-01

    Despite common acknowledgement of the value of protected areas as instruments in ensuring sustainability, and their promotion for the achievement of policies on halting the loss of biodiversity, there is no common approach today for monitoring and evaluating them. This paper presents a novel integrated nature conservation management procedure developed to monitor and evaluate the sustainability of Mediterranean protected areas. This procedure was successfully implemented and formally evaluated by protected area managers in six Mediterranean countries, results of which are presented here together with an overview of the web-based Decision Support System (DSS) developed to facilitate its wide adoption. The DSS and procedure has been designed and evaluated by managers as a useful tool, which facilitates and provides needed procedural guidance for protected area monitoring whilst minimizing input requirements to do so. The procedure and DSS were developed following a review of existing protected area assessment tools and a detailed primary investigation of the needs and capacity of its intended users. Essentially, the procedure and DSS guides provide the facilities for protected area managers, in following a participatory approach to develop a context-specific sustainability monitoring strategy, for their protected area. Consequently, the procedure is, by design, participatory, context specific, holistic and relevant to protected area management and institutional procedures. The procedure was piloted and formally evaluated in Greece, Italy, Turkey, Egypt, Malta and Cyprus. Feedback collected from the pilot evaluations is also summarised herein.

  16. Head-camera video recordings of trauma core competency procedures can evaluate surgical resident's technical performance as well as colocated evaluators.

    PubMed

    Mackenzie, Colin F; Pasley, Jason; Garofalo, Evan; Shackelford, Stacy; Chen, Hegang; Longinaker, Nyaradzo; Granite, Guinevere; Pugh, Kristy; Hagegeorge, George; Tisherman, Samuel A

    2017-07-01

    Unbiased evaluation of trauma core competency procedures is necessary to determine if residency and predeployment training courses are useful. We tested whether a previously validated individual procedure score (IPS) for individual procedure vascular exposure and fasciotomy (FAS) performance skills could discriminate training status by comparing IPS of evaluators colocated with surgeons to blind video evaluations. Performance of axillary artery (AA), brachial artery (BA), and femoral artery (FA) vascular exposures and lower extremity FAS on fresh cadavers by 40 PGY-2 to PGY-6 residents was video-recorded from head-mounted cameras. Two colocated trained evaluators assessed IPS before and after training. One surgeon in each pretraining tertile of IPS for each procedure was randomly identified for blind video review. The same 12 surgeons were video-recorded repeating the procedures less than 4 weeks after training. Five evaluators independently reviewed all 96 randomly arranged deidentified videos. Inter-rater reliability/consistency, intraclass correlation coefficients were compared by colocated versus video review of IPS, and errors. Study methodology and bias were judged by Medical Education Research Study Quality Instrument and the Quality Assessment of Diagnostic Accuracy Studies criteria. There were no differences (p ≥ 0.5) in IPS for AA, FA, FAS, whether evaluators were colocated or reviewed video recordings. Evaluator consistency was 0.29 (BA) - 0.77 (FA). Video and colocated evaluators were in total agreement (p = 1.0) for error recognition. Intraclass correlation coefficient was 0.73 to 0.92, dependent on procedure. Correlations video versus colocated evaluations were 0.5 to 0.9. Except for BA, blinded video evaluators discriminated (p < 0.002) whether procedures were performed before training versus after training. Study methodology by Medical Education Research Study Quality Instrument criteria scored 15.5/19, Quality Assessment of Diagnostic Accuracy Studies 2 showed low bias risk. Video evaluations of AA, FA, and FAS procedures with IPS are unbiased, valid, and have potential for formative assessments of competency. Prognostic study, level II.

  17. Evaluation of site plan review procedures.

    DOT National Transportation Integrated Search

    1988-01-01

    The site plan review procedures of the Virginia Department of Transportation (VDOT) were evaluated. The objectives of the evaluation were to recommend (1) a set of site plan review procedures including a checklist, (2) definitions of the roles and re...

  18. The Evaluation of Foreign-Language-Teacher Education Programmes

    ERIC Educational Resources Information Center

    Peacock, Matthew

    2009-01-01

    This article presents a new procedure for the evaluation of EFL teacher-training programmes based on principles of programme evaluation and foreign-language-teacher (FLT) education. The procedure focuses on programme strengths and weaknesses and how far the programme meets the needs of students. I tested the procedure through an evaluation of a…

  19. Evaluation of standardized sample collection, packaging, and decontamination procedures to assess cross-contamination potential during Bacillus anthracis incident response operations

    PubMed Central

    Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall

    2016-01-01

    Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274

  20. Evaluation of standardized sample collection, packaging, and decontamination procedures to assess cross-contamination potential during Bacillus anthracis incident response operations.

    PubMed

    Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall

    2016-12-01

    Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.

  1. 42 CFR 422.502 - Evaluation and determination procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES (CONTINUED) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Application Procedures and Contracts for Medicare Advantage Organizations § 422.502 Evaluation and determination procedures. (a) Basis for...

  2. Implications of cost-effectiveness analysis of medical technology. background paper number 5. four common x-ray procedures: problems and prospects for economic evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, J.L.; Krieger, M.J.

    This paper is about the economic evaluation of diagnostic procedures. The issue of economic evaluation is explored in the context of four common diagnostic X-ray procedures: the chest X-ray, the skull X-ray, the barium enema study, and the excretory urogram. The paper is divided into two parts. The first part summarizes the different evaluative models underlying studies of the four diagnostic X-ray procedures and to lay out the strengths and weaknesses of each method. The second part contains four separate chapters summarizing what is known about the utilization, costs, risks, and benefits of each procedure, with particular emphasis on themore » evaluative methods employed.« less

  3. Systematic Evaluation of Professional Performance: Legally Supported Procedure and Process.

    ERIC Educational Resources Information Center

    Kerl, Stella Beatriz; Garcia, John L.; McCullough, C. Sue; Maxwell, Melissa Elaine

    2002-01-01

    Legal challenges to counseling students' dismissal that are based on interpersonal or clinical incompetence require sound systematic academic evaluation and adherence to procedural and substantive due process. Presents an examination of professional competency from counselor education and legal perspectives, an evaluation procedure and process,…

  4. 28 CFR 104.31 - Procedure for claims evaluation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Procedure for claims evaluation. 104.31 Section 104.31 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) SEPTEMBER 11TH VICTIM... any required documents. (b) Procedural tracks. Each claim will be placed on a procedural track...

  5. 28 CFR 104.31 - Procedure for claims evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Procedure for claims evaluation. 104.31 Section 104.31 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) SEPTEMBER 11TH VICTIM... any required documents. (b) Procedural tracks. Each claim will be placed on a procedural track...

  6. Student Services Program Planning and Evaluation: Responsibility, Procedures, Instrument, and Guidelines.

    ERIC Educational Resources Information Center

    Repp, Charles A.; Brach, Ronald C.

    The manual provides a rationale, procedural guidelines, time-schedules, instruments, and supporting documentation for student services program evaluation at SUNY Agricultural and Technical College, Delhi. Six procedural guidelines include: (1) all programs and services should be evaluated at least once every four years, with provision for annual…

  7. Least-squares finite element solution of 3D incompressible Navier-Stokes problems

    NASA Technical Reports Server (NTRS)

    Jiang, Bo-Nan; Lin, Tsung-Liang; Povinelli, Louis A.

    1992-01-01

    Although significant progress has been made in the finite element solution of incompressible viscous flow problems. Development of more efficient methods is still needed before large-scale computation of 3D problems becomes feasible. This paper presents such a development. The most popular finite element method for the solution of incompressible Navier-Stokes equations is the classic Galerkin mixed method based on the velocity-pressure formulation. The mixed method requires the use of different elements to interpolate the velocity and the pressure in order to satisfy the Ladyzhenskaya-Babuska-Brezzi (LBB) condition for the existence of the solution. On the other hand, due to the lack of symmetry and positive definiteness of the linear equations arising from the mixed method, iterative methods for the solution of linear systems have been hard to come by. Therefore, direct Gaussian elimination has been considered the only viable method for solving the systems. But, for three-dimensional problems, the computer resources required by a direct method become prohibitively large. In order to overcome these difficulties, a least-squares finite element method (LSFEM) has been developed. This method is based on the first-order velocity-pressure-vorticity formulation. In this paper the LSFEM is extended for the solution of three-dimensional incompressible Navier-Stokes equations written in the following first-order quasi-linear velocity-pressure-vorticity formulation.

  8. Evaluation of a technique to simplify depictions of visually complex aeronautical procedures for NextGen

    DOT National Transportation Integrated Search

    2013-10-04

    Performance based navigation supports the design of more precise flight procedures. However, these new procedures can be visually complex, which may impact the usability of charts that depict the procedures. The purpose of the study was to evaluate w...

  9. Designing Flightdeck Procedures

    NASA Technical Reports Server (NTRS)

    Barshi, Immanuel; Mauro, Robert; Degani, Asaf; Loukopoulou, Loukia

    2016-01-01

    The primary goal of this document is to provide guidance on how to design, implement, and evaluate flight deck procedures. It provides a process for developing procedures that meet clear and specific requirements. This document provides a brief overview of: 1) the requirements for procedures, 2) a process for the design of procedures, and 3) a process for the design of checklists. The brief overview is followed by amplified procedures that follow the above steps and provide details for the proper design, implementation and evaluation of good flight deck procedures and checklists.

  10. Test Operations Procedure (TOP) 08-2-188 Chemical Point Detector Vapor Testing

    DTIC Science & Technology

    2018-04-27

    Evaluation Command 6617 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S...AND EVALUATION COMMAND TEST OPERATIONS PROCEDURE *Test Operations Procedure 08-2-188 27 April 2018 DTIC AD No. CHEMICAL POINT DETECTOR VAPOR...188 27 April 2018 2 1. SCOPE. This Test Operations Procedure (TOP), which has been endorsed by the Test and Evaluation Capabilities and

  11. A framework for the evaluation of new interventional procedures.

    PubMed

    Lourenco, Tania; Grant, Adrian M; Burr, Jennifer M; Vale, Luke

    2012-03-01

    The introduction of new interventional procedures is less regulated than for other health technologies such as pharmaceuticals. Decisions are often taken on evidence of efficacy and short-term safety from small-scale usually observational studies. This reflects the particular challenges of evaluating interventional procedures - the extra facets of skill and training and the difficulty defining a 'new' technology. Currently, there is no framework to evaluate new interventional procedures before they become available in clinical practice as opposed to new pharmaceuticals. This paper proposes a framework to guide the evaluation of a new interventional procedure. A framework was developed consisting of a four-stage progressive evaluation for a new interventional procedure: Stage 1: Development; Stage 2: Efficacy and short-term safety; Stage 3: Effectiveness and cost-effectiveness; and Stage 4: Implementation. The framework also suggests the types of studies or data collection methods that can be used to satisfy each stage. This paper makes a first step on a framework for generating evidence on new interventional procedures. The difficulties and limitations of applying such a framework are discussed. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. Evaluation of Bias-Variance Trade-Off for Commonly Used Post-Summarizing Normalization Procedures in Large-Scale Gene Expression Studies

    PubMed Central

    Qiu, Xing; Hu, Rui; Wu, Zhixin

    2014-01-01

    Normalization procedures are widely used in high-throughput genomic data analyses to remove various technological noise and variations. They are known to have profound impact to the subsequent gene differential expression analysis. Although there has been some research in evaluating different normalization procedures, few attempts have been made to systematically evaluate the gene detection performances of normalization procedures from the bias-variance trade-off point of view, especially with strong gene differentiation effects and large sample size. In this paper, we conduct a thorough study to evaluate the effects of normalization procedures combined with several commonly used statistical tests and MTPs under different configurations of effect size and sample size. We conduct theoretical evaluation based on a random effect model, as well as simulation and biological data analyses to verify the results. Based on our findings, we provide some practical guidance for selecting a suitable normalization procedure under different scenarios. PMID:24941114

  13. A new vision of carbonate slopes: the Little Bahama Bank

    NASA Astrophysics Data System (ADS)

    Mulder, Thierry; Gillet, Hervé; Hanquiez, Vincent; Reijmer, John J.; Tournadour, Elsa; Chabaud, Ludivine; Principaud, Mélanie; Schnyder, Jara; Borgomano, Jean

    2015-04-01

    Recent data collected in November 2014 (RV Walton Smith) on the upper slope of the Little Bahama Bank (LBB) between 30 and 400 m water depth allowed to characterize the uppermost slope (Rankey et al., 2012) over a surface of 170 km2. The new data set includes multibeam bathymetry and acoustic imagery, 3.5 kHz very-high resolution (VHR) seismic reflection lines, 21 gravity cores and 11 Van Veen grabs. The upper slope of the LBB does not show a steep submarine cliff as known from western Great Bahama Bank. The carbonate bank progressively deepens towards the basin through a slighty inclined plateau. The slope value is < 6° down to a water depth of about 70 m. The plateau is incised by decameter-wide gullies that covered with indurated sediment. Some of the gullies like Roberts Cuts show a larger size and may play an important role in sediment transfer from the shallow-water carbonate bank down to the canyon heads at 400-500 m water depth (Mulder et al., 2012). In the gully area, the actual reef rests on paleo-reefs that outcrop at a water depth of about 40 m. These paleo-reef structures could represent reefs that established themselves during past periods of sea-level stagnation. Below this water depth, the slope steepens up to 30° to form the marginal escarpment (Rankey et al., 2012), which is succeeded by the open margin realm (Rankey et al., 2012). The slope inclination value decreases at about 180-200 m water depth. Between 20 and 200 m of water depth, the VHR seismic shows no seafloor sub-bottom reflector. Between 180 and 320 m water depth, the seafloor smoothens. The VHR seismic shows an onlapping sediment wedge, which starts in this water depth and shows a blind or very crudely stratified echo facies. The sediment thickness of this Holocene unit may exceed 20 m. It fills small depressions in the substratum and thickens in front of gullies that cut the carbonate platform edge. Sediment samples show the abundancy of carbonate mud on the present Bahamian seafloor. In gullies, coarser sediment can be found. In some case, soft sediments are absent suggesting by-passing. At water depth between 40 and 100 m, the present-day seafloor is covered with bioclastic sediments. The main carbonate producer seems to be the alga genus Halimeda. Sediments collected in the deeper part of the basin (water depth = 1080 m) on the distal lobe consist of massive fine to medium well-sorted aragonitic sand. This suggests that carbonate slope systems are able to sort sediment despite the relative short slope distance. Sorting could either be due to flow spilling above the terraces identified in the canyon heads (Mulder et al., 2012) or could result from bottom currents. In this area, flow velocity profiles in the water column show the presence of two superposed water masses with a pycnocline at about 600-700 m water depth. Mulder, T., Ducassou, E., Gillet, H., Hanquiez, V., Tournadour, E., Combes, J., Eberli, G.P, Kindler, P., Gonthier, E., Conesa, G., Robin, C., Sianipar, R., Reijmer, J.J.G., and François A. Canyon morphology on a modern carbonate slope of the Bahamas: Evidence of regional tectonic tilting. Geology, 40(9), 771-774. Rankey, E.C, and Doolittle, D.F. (2012). Geomorphology of carbonate platform-marginal uppermost slopes: Insights from a Holocene analogue, Little Bahama Bank, Bahamas. Sedimentology, 59, 2146-2171.

  14. Visual Contrast Sensitivity Functions Obtained from Untrained Observers Using Tracking and Staircase Procedures. Final Report.

    ERIC Educational Resources Information Center

    Geri, George A.; Hubbard, David C.

    Two adaptive psychophysical procedures (tracking and "yes-no" staircase) for obtaining human visual contrast sensitivity functions (CSF) were evaluated. The procedures were chosen based on their proven validity and the desire to evaluate the practical effects of stimulus transients, since tracking procedures traditionally employ gradual…

  15. 49 CFR Appendix C to Part 242 - Procedures for Obtaining and Evaluating Motor Vehicle Driving Record Data

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Procedures for Obtaining and Evaluating Motor Vehicle Driving Record Data C Appendix C to Part 242 Transportation Other Regulations Relating to... CERTIFICATION OF CONDUCTORS Pt. 242, App. C Appendix C to Part 242—Procedures for Obtaining and Evaluating Motor...

  16. 49 CFR Appendix C to Part 242 - Procedures for Obtaining and Evaluating Motor Vehicle Driving Record Data

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Procedures for Obtaining and Evaluating Motor Vehicle Driving Record Data C Appendix C to Part 242 Transportation Other Regulations Relating to... CERTIFICATION OF CONDUCTORS Pt. 242, App. C Appendix C to Part 242—Procedures for Obtaining and Evaluating Motor...

  17. Evaluation of a procedure for reducing vehicle-tree accidents.

    DOT National Transportation Integrated Search

    1987-01-01

    A procedure for reducing vehicle-tree accidents was evaluated. The procedure, developed by the Michigan Department of Transportation, consists of five steps: (1) preparing a base map and plotting roadway information, (2) assigning priorities for fiel...

  18. Early learning effect of residents for laparoscopic sigmoid resection.

    PubMed

    Bosker, Robbert; Groen, Henk; Hoff, Christiaan; Totte, Eric; Ploeg, Rutger; Pierie, Jean-Pierre

    2013-01-01

    To evaluate the effect of learning the laparoscopic sigmoid resection procedure on resident surgeons; establish a minimum number of cases before a resident surgeon could be expected to achieve proficiency with the procedure; and examine if an analysis could be used to measure and support the clinical evaluation of the surgeon's competence with the procedure. Retrospective analysis of data which was prospective entered in the database. From 2003 to 2007 all patients who underwent a laparoscopic sigmoid resection carried out by senior residents, who completed the procedure as the primary surgeon proctored by an experienced surgeon, were included in the study. A cumulative sum control chart (CUSUM) analysis was used evaluate performance. The procedure was defined as a failure if major intra-operative complications occurred such as intra abdominal organ injury, bleeding, or anastomotic leakage; if an inadequate number of lymph nodes (<12 nodes) were removed; or if conversion to an open surgical procedure was required. Thirteen residents performed 169 laparoscopic sigmoid resections in the period evaluated. A significant majority of the resident surgeons were able to consistently perform the procedure without failure after 11 cases and determined to be competent. One resident was not determined to be competent and the CUSUM score supported these findings. We concluded that at least 11 cases are required for most residents to obtain necessary competence with the laparoscopic sigmoid resection procedure. Evaluation with the CUSUM analysis can be used to measure and support the clinical evaluation of the resident surgeon's competence with the procedure. Copyright © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. Efficacy Outcome Measures for Procedural Sedation Clinical Trials in Adults: An ACTTION Systematic Review.

    PubMed

    Williams, Mark R; McKeown, Andrew; Dexter, Franklin; Miner, James R; Sessler, Daniel I; Vargo, John; Turk, Dennis C; Dworkin, Robert H

    2016-01-01

    Successful procedural sedation represents a spectrum of patient- and clinician-related goals. The absence of a gold-standard measure of the efficacy of procedural sedation has led to a variety of outcomes being used in clinical trials, with the consequent lack of consistency among measures, making comparisons among trials and meta-analyses challenging. We evaluated which existing measures have undergone psychometric analysis in a procedural sedation setting and whether the validity of any of these measures support their use across the range of procedures for which sedation is indicated. Numerous measures were found to have been used in clinical research on procedural sedation across a wide range of procedures. However, reliability and validity have been evaluated for only a limited number of sedation scales, observer-rated pain/discomfort scales, and satisfaction measures in only a few categories of procedures. Typically, studies only examined 1 or 2 aspects of scale validity. The results are likely unique to the specific clinical settings they were tested in. Certain scales, for example, those requiring motor stimulation, are unsuitable to evaluate sedation for procedures where movement is prohibited (e.g., magnetic resonance imaging scans). Further work is required to evaluate existing measures for procedures for which they were not developed. Depending on the outcomes of these efforts, it might ultimately be necessary to consider measures of sedation efficacy to be procedure specific.

  20. Defining Autism: Variability in State Education Agency Definitions of and Evaluations for Autism Spectrum Disorders

    PubMed Central

    Pennington, Malinda L.; Cullinan, Douglas; Southern, Louise B.

    2014-01-01

    In light of the steady rise in the prevalence of students with autism, this study examined the definition of autism published by state education agencies (SEAs), as well as SEA-indicated evaluation procedures for determining student qualification for autism. We compared components of each SEA definition to aspects of autism from two authoritative sources: Diagnostic and Statistical Manual of Mental Disorders (DSM-IV-TR) and Individuals with Disabilities Education Improvement Act (IDEA-2004). We also compared SEA-indicated evaluation procedures across SEAs to evaluation procedures noted in IDEA-2004. Results indicated that many more SEA definitions incorporate IDEA-2004 features than DSM-IV-TR features. However, despite similar foundations, SEA definitions of autism displayed considerable variability. Evaluation procedures were found to vary even more across SEAs. Moreover, within any particular SEA there often was little concordance between the definition (what autism is) and evaluation procedures (how autism is recognized). Recommendations for state and federal policy changes are discussed. PMID:24987527

  1. 48 CFR 42.1503 - Procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... CONTRACT ADMINISTRATION AND AUDIT SERVICES Contractor Performance Information 42.1503 Procedures. (a) Agency procedures for the past performance evaluation system shall generally provide for input to the.... Those individuals identified may obtain information for the evaluation of performance from the program...

  2. The Bookmark Procedure for Setting Cut-Scores and Finalizing Performance Standards: Strengths and Weaknesses

    ERIC Educational Resources Information Center

    Lin, Jie

    2006-01-01

    The Bookmark standard-setting procedure was developed to address the perceived problems with the most popular method for setting cut-scores: the Angoff procedure (Angoff, 1971). The purposes of this article are to review the Bookmark procedure and evaluate it in terms of Berk's (1986) criteria for evaluating cut-score setting methods. The…

  3. 9 CFR 147.16 - Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). 147.16 Section 147.16 Animals and Animal Products... the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). This procedure has been shown...

  4. 47 CFR 1.2202 - Competitive bidding design options.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 1.2202 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND PROCEDURE Grants...) Procedures that utilize mathematical computer optimization software, such as integer programming, to evaluate... evaluating bids using a ranking based on specified factors. (B) Procedures that combine computer optimization...

  5. Evaluation of flaws in carbon steel piping. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zahoor, A.; Gamble, R.M.; Mehta, H.S.

    1986-10-01

    The objective of this program was to develop flaw evaluation procedures and allowable flaw sizes for ferritic piping used in light water reactor (LWR) power generation facilities. The program results provide relevant ASME Code groups with the information necessary to define flaw evaluation procedures, allowable flaw sizes, and their associated bases for Section XI of the code. Because there are several possible flaw-related failure modes for ferritic piping over the LWR operating temperature range, three analysis methods were employed to develop the evaluation procedures. These include limit load analysis for plastic collapse, elastic plastic fracture mechanics (EPFM) analysis for ductilemore » tearing, and linear elastic fracture mechanics (LEFM) analysis for non ductile crack extension. To ensure the appropriate analysis method is used in an evaluation, a step by step procedure also is provided to identify the relevant acceptance standard or procedure on a case by case basis. The tensile strength and toughness properties required to complete the flaw evaluation for any of the three analysis methods are included in the evaluation procedure. The flaw evaluation standards are provided in tabular form for the plastic collapse and ductile tearing modes, where the allowable part through flaw depth is defined as a function of load and flaw length. For non ductile crack extension, linear elastic fracture mechanics analysis methods, similar to those in Appendix A of Section XI, are defined. Evaluation flaw sizes and procedures are developed for both longitudinal and circumferential flaw orientations and normal/upset and emergency/faulted operating conditions. The tables are based on margins on load of 2.77 and 1.39 for circumferential flaws and 3.0 and 1.5 for longitudinal flaws for normal/upset and emergency/faulted conditions, respectively.« less

  6. Evaluation Procedures in the Charlotte-Mecklenburg Career Ladder Plan.

    ERIC Educational Resources Information Center

    Schlechty, Phillip C.

    1985-01-01

    Describes faculty evaluation procedures used in the Charlotte-Mecklenburg (North Carolina) Public Schools in conjunction with career development. Covers the program's philosophy, purposes, and special characteristics; expectations set and competencies sought; the areas evaluation; evaluator characteristics; the observation process; teachers'…

  7. 48 CFR 1436.602-2 - Evaluation boards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Evaluation boards. 1436...-2 Evaluation boards. HCAs shall establish procedures for providing permanent or ad hoc architect-engineer evaluation boards. Bureau procedures shall provide for the appointment of private practitioners of...

  8. AgRISTARS: Foreign commodity production forecasting. The 1980 US corn and soybeans exploratory experiment

    NASA Technical Reports Server (NTRS)

    Malin, J. T.; Carnes, J. G. (Principal Investigator)

    1981-01-01

    The U.S. corn and soybeans exploratory experiment is described which consisted of evaluations of two technology components of a production forecasting system: classification procedures (crop labeling and proportion estimation at the level of a sampling unit) and sampling and aggregation procedures. The results from the labeling evaluations indicate that the corn and soybeans labeling procedure works very well in the U.S. corn belt with full season (after tasseling) LANDSAT data. The procedure should be readily adaptable to corn and soybeans labeling required for subsequent exploratory experiments or pilot tests. The machine classification procedures evaluated in this experiment were not effective in improving the proportion estimates. The corn proportions produced by the machine procedures had a large bias when the bias correction was not performed. This bias was caused by the manner in which the machine procedures handled spectrally impure pixels. The simulation test indicated that the weighted aggregation procedure performed quite well. Although further work can be done to improve both the simulation tests and the aggregation procedure, the results of this test show that the procedure should serve as a useful baseline procedure in future exploratory experiments and pilot tests.

  9. Program Evaluation of a Special Education Day School for Conduct Problem Adolescents.

    ERIC Educational Resources Information Center

    Maher, Charles A.

    1981-01-01

    Describes a procedure for program evaluation of a special education day school. The procedure enables a program evaluator to: (1) identify priority evaluation information needs of a school staff, (2) involve those persons in evaluation design and implementation, and (3) determine the utility of the evaluation for program decision-making purposes.…

  10. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    PubMed

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. 76 FR 27016 - Evaluating Test Procedures for Voting Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-10

    ...-02] Evaluating Test Procedures for Voting Systems AGENCY: National Institute of Standards and... Assistance Commission for use by NIST in research to develop and assess NIST's test procedures for voting... develop and assess NIST test protocols for voting equipment. NIST research is designed to: (1) Develop...

  12. Army Blast Claims Evaluation Procedures

    DTIC Science & Technology

    1994-03-01

    ARMY RESEARCH LABORATORY ARL-MR-131 Army Blast Claims Evaluation Procedures William P. Wright APPROVED FOR PUBUC RELEASE; DISTRIBtmON IS...NUMBERS Anny Blast Claims Evaluation Procedures 4G061-304-U2 6. AUTHOR(S) William P. Wrisht 1. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8...of the technical review process which bas been instituted to develop an opinion as to Army responsibility. 14. SUBJECT TERMS blast effects. muzzle

  13. 48 CFR 570.203-4 - Negotiation, evaluation, and award.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Negotiation, evaluation... Acquisition Procedures 570.203-4 Negotiation, evaluation, and award. (a) If the contracting officer needs to conduct negotiations, use the procedures in 570.307. (b) Evaluate offers in accordance with the...

  14. 48 CFR 570.203-4 - Negotiation, evaluation, and award.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Negotiation, evaluation... Acquisition Procedures 570.203-4 Negotiation, evaluation, and award. (a) If the contracting officer needs to conduct negotiations, use the procedures in 570.307. (b) Evaluate offers in accordance with the...

  15. 48 CFR 570.203-4 - Negotiation, evaluation, and award.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Negotiation, evaluation... Acquisition Procedures 570.203-4 Negotiation, evaluation, and award. (a) If the contracting officer needs to conduct negotiations, use the procedures in 570.307. (b) Evaluate offers in accordance with the...

  16. 48 CFR 570.203-4 - Negotiation, evaluation, and award.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Negotiation, evaluation... Acquisition Procedures 570.203-4 Negotiation, evaluation, and award. (a) If the contracting officer needs to conduct negotiations, use the procedures in 570.307. (b) Evaluate offers in accordance with the...

  17. Evaluation of lumbar transforaminal epidural injections with needle placement and contrast flow patterns: a prospective, descriptive report.

    PubMed

    Manchikanti, Laxmaiah; Cash, Kim A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D

    2004-04-01

    Transforaminal epidural steroid injection is one of the commonly employed modalities of treatment in managing nerve root pain. However, there have been no controlled prospective evaluations of epidural and nerve root contrast distribution patterns and other aspects of fluoroscopically directed lumbosacral transforaminal epidural steroid injections. To evaluate contrast flow patterns and intravascular needle placement of fluoroscopically guided lumbosacral transforaminal epidural injections. A prospective, observational study. A total of 100 consecutive patients undergoing fluoroscopically guided transforaminal epidural steroid injections were evaluated. The contrast flow patterns, ventral or dorsal epidural filling, nerve root filling, C-arm time, and intravascular needle placement were evaluated. Ventral epidural filling was seen in 88% of the procedures, in contrast to dorsal filling noted in 9% of the procedures. Nerve root filling was seen in 97% of the procedures. Total intravenous placement of the needle was noted in 22% of the procedures, whereas negative flashback and aspiration was noted in 5% of the procedures. Lumbosacral transforaminal epidural injections, performed under fluoroscopic visualization, provide excellent nerve root filling and ventral epidural filling patterns. However, unrecognized intravascular needle placement with negative flashback or aspiration was noted in 5% of the procedures.

  18. Loudness judgment procedures for evaluating hearing aid preselection decisions for severely and profoundly hearing-impaired listeners.

    PubMed

    Gottermeier, L; De Filippo, C L; Block, M G

    1991-08-01

    Hearing aid fitting involves a two-phase process of preselection and evaluation (Seewald RC and Ross M. Amplification for the Hearing Impaired 1988:213-271). The purpose of the present study was to examine alternative procedures that clinicians might use in the evaluation phase to verify the adequacy of hearing aid preselection decisions for severely and profoundly hearing-impaired listeners. Bekesy tracking, loudness rating, and conventional bracketing procedures were used to determine threshold, most comfortable listening level, and uncomfortable listening level for 10 hearing-impaired young adults. Stimuli were pulsed pure tones of 500, 1000, and 2000 Hz and filtered words. Means and standard deviations of most comfortable listening levels and uncomfortable listening levels derived from loudness judgments of the 10 subjects showed only nominal differences across procedures. However, correlation analysis (Pearson r) indicated that individuals responded to the three procedures in varying ways, producing different loudness judgments and overall dynamic ranges. Thus, test procedure may influence the clinician's final evaluation of a preselected hearing aid. Initial work suggests that closed-set response categories such as loudness rating can limit measurement variability and potentially guide the clinician's evaluation of hearing aid preselection decisions.

  19. Development of a safety evaluation procedure for identifying high-risk signalized intersections in the Virginia Department of Transportation's Northern Virginia district.

    DOT National Transportation Integrated Search

    2007-01-01

    This research was undertaken to develop an evaluation procedure to identify high-risk four-legged signalized intersections in VDOT's Northern Virginia district by traffic movements and times of day. By using the developed procedure, traffic engineers...

  20. Qualitative Parameters for Evaluation Procedures of Non-Formal and Informal Learning Achievements

    ERIC Educational Resources Information Center

    Stasiunaitiene, Egle; Kaminskiene, Lina

    2009-01-01

    The article introduces evaluation principles of non-formal and informal learning that determine the quality of evaluation, describes stages of the evaluation procedure, differentiates their qualitative parameters and defines their criteria and indicators. It also brings in the discussion that consideration of qualitative parameters for the…

  1. 34 CFR 303.342 - Procedures for IFSP development, review, and evaluation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAM FOR INFANTS AND TODDLERS WITH DISABILITIES Child Find, Evaluations and Assessments, and... development, review, and evaluation. (a) Meeting to develop initial IFSP—timelines. For a child referred to... 34 Education 2 2014-07-01 2013-07-01 true Procedures for IFSP development, review, and evaluation...

  2. 34 CFR 303.342 - Procedures for IFSP development, review, and evaluation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAM FOR INFANTS AND TODDLERS WITH DISABILITIES Child Find, Evaluations and Assessments, and... development, review, and evaluation. (a) Meeting to develop initial IFSP—timelines. For a child referred to... 34 Education 2 2013-07-01 2013-07-01 false Procedures for IFSP development, review, and evaluation...

  3. 34 CFR 303.342 - Procedures for IFSP development, review, and evaluation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAM FOR INFANTS AND TODDLERS WITH DISABILITIES Child Find, Evaluations and Assessments, and... development, review, and evaluation. (a) Meeting to develop initial IFSP—timelines. For a child referred to... 34 Education 2 2012-07-01 2012-07-01 false Procedures for IFSP development, review, and evaluation...

  4. Standards for Title VII Evaluations: Accommodation for Reality Constraints.

    ERIC Educational Resources Information Center

    Yap, Kim Onn

    Two separate sets of minimum standards designed to guide the evaluation of bilingual projects are proposed. The first set relates to the process in which the evaluation activities are conducted. They include: validity of assessment procedures, validity and reliability of evaluation instruments, representativeness of findings, use of procedures for…

  5. Evaluating Community College Personnel: A Research Report.

    ERIC Educational Resources Information Center

    Deegan, William L.; And Others

    A statewide survey was conducted of local evaluation policies, procedures, and problems of implementing evaluation programs on the campuses of California community colleges. The following areas were studied: (1) the process of development of the evaluation program; (2) procedures utilized in the first year of implementing Senate Bill 696…

  6. An improved filter elution and cell culture assay procedure for evaluating public groundwater systems for culturable enteroviruses.

    PubMed

    Dahling, Daniel R

    2002-01-01

    Large-scale virus studies of groundwater systems require practical and sensitive procedures for both sample processing and viral assay. Filter adsorption-elution procedures have traditionally been used to process large-volume water samples for viruses. In this study, five filter elution procedures using cartridge filters were evaluated for their effectiveness in processing samples. Of the five procedures tested, the third method, which incorporated two separate beef extract elutions (one being an overnight filter immersion in beef extract), recovered 95% of seeded poliovirus compared with recoveries of 36 to 70% for the other methods. For viral enumeration, an expanded roller bottle quantal assay was evaluated using seeded poliovirus. This cytopathic-based method was considerably more sensitive than the standard plaque assay method. The roller bottle system was more economical than the plaque assay for the evaluation of comparable samples. Using roller bottles required less time and manipulation than the plaque procedure and greatly facilitated the examination of large numbers of samples. The combination of the improved filter elution procedure and the roller bottle assay for viral analysis makes large-scale virus studies of groundwater systems practical. This procedure was subsequently field tested during a groundwater study in which large-volume samples (exceeding 800 L) were processed through the filters.

  7. 40 CFR 610.52 - Maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.52 Maintenance. (a) Maintenance during the durability evaluation can best be considered in three separate categories: (1) Normal... durability evaluation in this program will probably have considerable mileage accumulation and unknown...

  8. Endoscopic ultrasound and endoscopic retrograde cholangiopancreatography for obstructing pancreas head masses: combined or separate procedures?

    PubMed

    Aslanian, Harry R; Estrada, Juan D; Rossi, Federico; Dziura, James; Jamidar, Priya A; Siddiqui, Uzma D

    2011-09-01

    Endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) are complementary procedures in the evaluation of obstructive jaundice. To determine the feasibility, accuracy, and safety of the combined performance of EUS-guided fine needle aspiration (FNA) and ERCP with biliary stenting in patients with obstructive jaundice. Retrospectively reviewed data from consecutive patients presenting with obstructive jaundice due to a pancreas mass at a tertiary referral hospital between April 2002 and November 2007 who underwent combined (under the same sedation and in the same room) or separate EUS and ERCP. Procedure duration, amount of sedative medication administered, ability to achieve biliary stent placement, and the diagnostic yield of EUS-FNA were evaluated. A total of 47 patients were evaluated: 29 patients underwent combined EUS and ERCP and 18 had separate procedures (median of 5 d between procedures). Stent placement at ERCP was successful in 72% combined procedures versus 88% separate ERCP. EUS-FNA diagnosis of malignancy was positive in 91.6% combined versus 87.5% separate. The only complication was self-limited melena after a combined procedure in 1 patient. The median time for combined procedures was 75 minutes versus 50 minutes for separate EUS and 50 minutes for ERCP. Combined EUS and ERCP can be performed under the same sedation with a median 25 minute greater procedure length and similarly high yields for diagnostic EUS-FNA. A nonsignificant trend toward lower biliary stent placement success rates with combined ERCP procedures merits further study. Benefits of a combined procedure may include expedited patient evaluation and the avoidance of repeated sedation.

  9. Elastic plastic fracture mechanics methodology for surface cracks

    NASA Technical Reports Server (NTRS)

    Ernst, Hugo A.; Lambert, D. M.

    1994-01-01

    The Elastic Plastic Fracture Mechanics Methodology has evolved significantly in the last several years. Nevertheless, some of these concepts need to be extended further before the whole methodology can be safely applied to structural parts. Specifically, there is a need to include the effect of constraint in the characterization of material resistance to crack growth and also to extend these methods to the case of 3D defects. As a consequence, this project was started as a 36 month research program with the general objective of developing an elastic plastic fracture mechanics methodology to assess the structural reliability of pressure vessels and other parts of interest to NASA which may contain flaws. The project is divided into three tasks that deal with (1) constraint and thickness effects, (2) three-dimensional cracks, and (3) the Leak-Before-Burst (LBB) criterion. This report period (March 1994 to August 1994) is a continuation of attempts to characterize three dimensional aspects of fracture present in 'two dimensional' or planar configuration specimens (Chapter Two), especially, the determination of, and use of, crack face separation data. Also, included, are a variety of fracture resistance testing results (J(m)R-curve format) and a discussion regarding two materials of NASA interest (6061-T651 Aluminum alloy and 1N718-STA1 nickel-base super alloy) involving a bases for like constraint in terms of ligament dimensions, and their comparison to the resulting J(m)R-curves (Chapter Two).

  10. Cross-national research on contractor evaluation procedures in public works procurement

    NASA Astrophysics Data System (ADS)

    Kinoshita, Seiya; Sato, Naoyoshi; Matsumoto, Naoya

    Contractor evaluation methods in Japan's public works procurement, beginning with construction business licensure, going through biennial preliminary firm rating, up to project-by-project prequalification and comprehensive point rating, were developed during the period when public works were mostly procured through designated competitive bidding. It is essential to focus attention on contractor evaluation methods for introducing different types of procurement procedures which enhance the use of technological capabilities held by private businesses. An overall review of contractor evaluation procedures should be conducted in view of the present situation, where the open competitive bidding has become mainly used in combination with comprehensive evaluation, as well as to allow for further diversification of procurement methods. In Western countries, improvements have been made for the past several years in contractor evaluation procedures with more emphasis on "Value for Money." Advanced efforts made by these countries will be useful as a reference for overhauling Japan's contractor evaluation system. This study conducts a comparative review of contractor evaluation procedures for public procurement in Western countries such as the United States, the United Kingdom and France by identifying similarities and differences between those of Japan and the above mentioned countries. This reveals that a contractor's technical or professional ability is looked at separately from its economic and financial standing in those countries studied, and there is no case like Japan in which those two factors are integrated into one for evaluation.

  11. Prevalidation in pharmaceutical analysis. Part I. Fundamentals and critical discussion.

    PubMed

    Grdinić, Vladimir; Vuković, Jadranka

    2004-05-28

    A complete prevalidation, as a basic prevalidation strategy for quality control and standardization of analytical procedure was inaugurated. Fast and simple, the prevalidation methodology based on mathematical/statistical evaluation of a reduced number of experiments (N < or = 24) was elaborated and guidelines as well as algorithms were given in detail. This strategy has been produced for the pharmaceutical applications and dedicated to the preliminary evaluation of analytical methods where linear calibration model, which is very often occurred in practice, could be the most appropriate to fit experimental data. The requirements presented in this paper should therefore help the analyst to design and perform the minimum number of prevalidation experiments needed to obtain all the required information to evaluate and demonstrate the reliability of its analytical procedure. In complete prevalidation process, characterization of analytical groups, checking of two limiting groups, testing of data homogeneity, establishment of analytical functions, recognition of outliers, evaluation of limiting values and extraction of prevalidation parameters were included. Moreover, system of diagnosis for particular prevalidation step was suggested. As an illustrative example for demonstration of feasibility of prevalidation methodology, among great number of analytical procedures, Vis-spectrophotometric procedure for determination of tannins with Folin-Ciocalteu's phenol reagent was selected. Favourable metrological characteristics of this analytical procedure, as prevalidation figures of merit, recognized the metrological procedure as a valuable concept in preliminary evaluation of quality of analytical procedures.

  12. Test Procedures for Characterizing, Evaluating, and Managing Separator Materials used in Secondary Alkaline Batteries

    NASA Technical Reports Server (NTRS)

    Guasp, Edwin; Manzo, Michelle A.

    1997-01-01

    Secondary alkaline batteries, such as nickel-cadmium and silver-zinc, are commonly used for aerospace applications. The uniform evaluation and comparison of separator properties for these systems is dependent upon the measurement techniques. This manual presents a series of standard test procedures that can be used to evaluate, compare, and select separator materials for use in alkaline batteries. Detailed test procedures evaluating the following characteristics are included in this manual: physical measurements of thickness and area weight, dimensional stability measurements, electrolyte retention, resistivity, permeability as measured via bubble pressure, surface evaluation via SEM, chemical stability, and tensile strength.

  13. Advanced crew procedures development techniques

    NASA Technical Reports Server (NTRS)

    Arbet, J. D.; Benbow, R. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.; Tatum, I. C.

    1975-01-01

    The development of an operational computer program, the Procedures and Performance Program (PPP), is reported which provides a procedures recording and crew/vehicle performance monitoring capability. The PPP provides real time CRT displays and postrun hardcopy of procedures, difference procedures, performance, performance evaluation, and training script/training status data. During post-run, the program is designed to support evaluation through the reconstruction of displays to any point in time. A permanent record of the simulation exercise can be obtained via hardcopy output of the display data, and via magnetic tape transfer to the Generalized Documentation Processor (GDP). Reference procedures data may be transferred from the GDP to the PPP.

  14. An analysis of contingency statements in a DRO procedure: A case report.

    PubMed

    Gerow, Stephanie; Rispoli, Mandy; Boles, Margot B; Neely, Leslie C

    2015-06-01

    To examine latency to criterion for reduction of challenging behaviour with and without stating a contingency statement immediately prior to a DRO procedure. An ABAC design in which A was baseline, B was used to evaluate the efficacy of a DRO procedure, and C was used to evaluate the efficacy of a DRO procedure with a contingency statement. The DRO with the contingency statement intervention was associated with a shorter latency to behaviour change than the DRO procedure without the contingency statement. These preliminary findings from this case study highlight the importance of examining the efficiency of behaviour change procedures. Directions for future research are provided.

  15. A management system for evaluating the Virginia periodic motor vehicle inspection program : software manual and implementation procedures : final report.

    DOT National Transportation Integrated Search

    1978-01-01

    This report deals with the Periodic Motor Vehicle Inspection Management Evaluation System software documentation and implementation procedures. A companion report entitled "A Management System for Evaluating the Virginia Periodic Motor Vehicle Inspec...

  16. Administrator Accountability Plan, 1986-87.

    ERIC Educational Resources Information Center

    Council Bluffs Community School District, IA.

    This summary outline presents performance evaluation procedures of the 1986-87 administrator accountability plan adopted by the Council Bluffs Community Schools, Iowa. Procedures ensure that a cooperative evaluation plan is established, there is continuity between evaluation cycles, guidance and assistance are provided, and due process is…

  17. [Examination of diagnosis procedure combination survey data that influence function evaluation coefficient II].

    PubMed

    Nakajima, Hisato; Yano, Kouya; Nagasawa, Kaoko; Kobayashi, Eiji; Yokota, Kuninobu

    2015-01-01

    On the basis of Diagnosis Procedure Combination (DPC) survey data, the factors that increase the value of function evaluation coefficient II were considered. A total of 1,505 hospitals were divided into groups I, II, and III, and the following items were considered. 1. Significant differences in function evaluation coefficient II and DPC survey data. 2. Examination of using the Mahalanobis-Taguchi (MT) method. 3. Correlation between function evaluation coefficient II and each DPC survey data item. 1. Function evaluation coefficient II was highest in group II. Group I hospitals showed the highest bed capacity, and numbers of hospitalization days, operations, chemotherapies, radiotherapies and general anesthesia procedures. 2. Using the MT method, we found that the number of ambulance conveyances was effective factor in group I hospitals, the number of general anesthesia procedures was effective factor in group II hospitals, and the bed capacity was effective factor in group III hospitals. 3. In group I hospitals, function evaluation coefficient II significantly correlated to the numbers of ambulance conveyances and chemotherapies. In group II hospitals, function evaluation coefficient II significantly correlated to bed capacity, the numbers of ambulance conveyances, hospitalization days, operations, general anesthesia procedures, and mean hospitalization days. In group III hospitals, function evaluation coefficient II significantly correlated to all items. The factors that improve the value of function evaluation coefficient II were the increases in the numbers of ambulance conveyances, chemotherapies and radiotherapies in group I hospitals, increases in the numbers of hospitalization days, operations, ambulance conveyances and general anesthesia procedures in group II hospitals, and increases in the numbers of hospitalization days, operations and ambulance conveyances. These results indicate that the profit of a hospital will increase, which will lead to medical services of good quality.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImagemore » co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.« less

  19. Evaluation Procedures for Training Psychotherapists in Interpersonal Psychotherapy (IPT).

    ERIC Educational Resources Information Center

    Chevron, Eve S.; And Others

    The training of psychotherapists has been an ongoing process in psychiatry and clinical psychology. Recently, however, a growing demand to operationalize competence criteria to enable independent evaluation of therapists' skills in specifically defined psychotherapies has occurred. To examine this phenomenon, evaluation procedures were developed…

  20. Modeling procedures for handling qualities evaluation of flexible aircraft

    NASA Technical Reports Server (NTRS)

    Govindaraj, K. S.; Eulrich, B. J.; Chalk, C. R.

    1981-01-01

    This paper presents simplified modeling procedures to evaluate the impact of flexible modes and the unsteady aerodynamic effects on the handling qualities of Supersonic Cruise Aircraft (SCR). The modeling procedures involve obtaining reduced order transfer function models of SCR vehicles, including the important flexible mode responses and unsteady aerodynamic effects, and conversion of the transfer function models to time domain equations for use in simulations. The use of the modeling procedures is illustrated by a simple example.

  1. The Evaluation of Published Indexes, and Abstract Journals:, Criteria and Possible Procedures

    PubMed Central

    Lancaster, F. W.

    1971-01-01

    This paper describes possible criteria by which the effectiveness of a published index may be evaluated and suggest procedures that might be used to conduct an evaluation of a published index. The procedures were developed for the National Library of Medicine and relate specifically to the recurring bibliographies produced by MEDLARS in various specialized areas of biomedicine. The methods described should, however, be applicable to other printed indexes and abstract journals. Factors affecting the performance of a published index are also discussed and some research projects relevant to the evaluation of published indexes are reviewed. PMID:5146770

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, K.

    Evaluate MicroLink cells as a function of temperature and spectral irradiance following the teams' standard procedures. These measurements will include the standard procedures for evaluating multijunction cells including quantum efficiency measurements and current versus voltage measurements.

  3. Evaluation of an Enhanced Stimulus-Stimulus Pairing Procedure to Increase Early Vocalizations of Children with Autism

    ERIC Educational Resources Information Center

    Esch, Barbara E.; Carr, James E.; Grow, Laura L.

    2009-01-01

    Evidence to support stimulus-stimulus pairing (SSP) in speech acquisition is less than robust, calling into question the ability of SSP to reliably establish automatically reinforcing properties of speech and limiting the procedure's clinical utility for increasing vocalizations. We evaluated the effects of a modified SSP procedure on…

  4. State Education Department: Security over Pupil Evaluation Program and Program Evaluation Test Materials Needs Improvement. Report 91-S-2.

    ERIC Educational Resources Information Center

    New York State Office of the Comptroller, Albany.

    Findings of an audit of the New York State Education Department's procedures to maintain security over Pupil Evaluation Program (PEP) and Program Evaluation Test (PET) examination materials are presented in this report. The audit sought to determine whether the department's security procedures adequately prevented unauthorized access to exam…

  5. A Guidebook for Evaluating Programs for the Gifted in Virginia School Divisions. A Cooperative Project.

    ERIC Educational Resources Information Center

    Pulaski County Schools, VA.

    This guidebook aims to provide clear, non-technical descriptions of procedures for evaluating the effectiveness of local gifted education programs in Virginia. The procedures were developed with both external and internal evaluations in mind. The evaluation process is described in four phases: planning, collecting the data, interpreting the data…

  6. Comparison of 2015 Medicare relative value units for gender-specific procedures: Gynecologic and gynecologic-oncologic versus urologic CPT coding. Has time healed gender-worth?

    PubMed

    Benoit, M F; Ma, J F; Upperman, B A

    2017-02-01

    In 1992, Congress implemented a relative value unit (RVU) payment system to set reimbursement for all procedures covered by Medicare. In 1997, data supported that a significant gender bias existed in reimbursement for gynecologic compared to urologic procedures. The present study was performed to compare work and total RVU's for gender specific procedures effective January 2015 and to evaluate if time has healed the gender-based RVU worth. Using the 2015 CPT codes, we compared work and total RVU's for 50 pairs of gender specific procedures. We also evaluated 2015 procedure related provider compensation. The groups were matched so that the procedures were anatomically similar. We also compared 2015 to 1997 RVU and fee schedules. Evaluation of work RVU's for the paired procedures revealed that in 36 cases (72%), male vs female procedures had a higher wRVU and tRVU. For total fee/reimbursement, 42 (84%) male based procedures were compensated at a higher rate than the paired female procedures. On average, male specific surgeries were reimbursed at an amount that was 27.67% higher for male procedures than for female-specific surgeries. Female procedure based work RVU's have increased minimally from 1997 to 2015. Time and effort have trended towards resolution of some gender-related procedure worth discrepancies but there are still significant RVU and compensation differences that should be further reviewed and modified as surgical time and effort highly correlate. Copyright © 2016. Published by Elsevier Inc.

  7. Procedural training and assessment of competency utilizing simulation.

    PubMed

    Sawyer, Taylor; Gray, Megan M

    2016-11-01

    This review examines the current environment of neonatal procedural learning, describes an updated model of skills training, defines the role of simulation in assessing competency, and discusses potential future directions for simulation-based competency assessment. In order to maximize impact, simulation-based procedural training programs should follow a standardized and evidence-based approach to designing and evaluating educational activities. Simulation can be used to facilitate the evaluation of competency, but must incorporate validated assessment tools to ensure quality and consistency. True competency evaluation cannot be accomplished with simulation alone: competency assessment must also include evaluations of procedural skill during actual clinical care. Future work in this area is needed to measure and track clinically meaningful patient outcomes resulting from simulation-based training, examine the use of simulation to assist physicians undergoing re-entry to practice, and to examine the use of procedural skills simulation as part of a maintenance of competency and life-long learning. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Rational design of aerobic digestion systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich, L.G.

    1987-06-01

    Deficiencies are identified in state-of-the-art procedures used in the design of systems for the aerobic digestion of waste-activated sludge solids. A procedure for the design of such systems on a rational basis is presented. Such a procedure not only includes a well-defined stabilization objective, but takes into account the stabilization that occurs in the activated sludge process. Related methods are discussed by which coefficients used in the design procedure can be evaluated. A design example is given. Further research and performance data derived from systems designed by the procedure are needed to better evaluate the parameters used and to testmore » the assumptions made in applying the procedure.« less

  9. Rational design of aerobic digestion systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich, L.G.

    1987-06-01

    Deficiencies are identified in state-of-the-art procedures used in the design of systems for the aerobic digestion of waste-activated sludge solids. A procedure for the design of such systems on a rational basis is presented. Such a procedure not only includes a well-defined stabilization objective, but takes into account the stabilization that occurs in the activated sludge process. Related methods are discussed by which coefficients used in the design procedure can be evaluated. A design example is given. Further research and performance data derived from systems designed by the procedure are needed to better evaluate the parameters used and to testmore » the assumptions made in applying the procedure. (Refs. 28).« less

  10. Methods of determination of periods in the motion of asteroids

    NASA Astrophysics Data System (ADS)

    Bien, R.; Schubart, J.

    Numerical techniques for the analysis of fundamental periods in asteroidal motion are evaluated. The specific techniques evaluated were: the periodogram analysis procedure of Wundt (1980); Stumpff's (1937) system of algebraic transformations; and Labrouste's procedure. It is shown that the Labrouste procedure permitted sufficient isolation of single oscillations from the quasi-periodic process of asteroidal motion. The procedure was applied to the analysis of resonance in the motion of Trojan-type and Hilda-type asteroids, and some preliminary results are discussed.

  11. The medical practice of euthanasia in Belgium and The Netherlands: legal notification, control and evaluation procedures.

    PubMed

    Smets, Tinne; Bilsen, Johan; Cohen, Joachim; Rurup, Mette L; De Keyser, Els; Deliens, Luc

    2009-05-01

    To describe and compare current legal procedures for notifying, controlling and evaluating (NCE-procedures) euthanasia in Belgium and the Netherlands, and to discuss the implications for a safe and controllable euthanasia practice. We systematically studied and compared official documents relating to the Belgian and the Dutch NCE-procedures for euthanasia. In both countries, physicians are required to notify their cases to a review Committee, stimulating them to safeguard the quality of their euthanasia practice and to make societal control over the practice of euthanasia possible. However, the procedures in both countries differ. The main differences are that the Dutch notification and control procedures are more elaborate and transparent than the Belgian, and that the Belgian procedures are primarily anonymous, whereas the Dutch are not. Societal evaluation is made in both countries through the Committees' summary reports to Parliament. Transparent procedures like the Dutch may better facilitate societal control. Informing physicians about the law and the due care requirements for euthanasia, and systematic feedback about their medical actions are both pivotal to achieving efficient societal control and engendering the level of care needed when performing such far-reaching medical acts.

  12. 40 CFR 90.427 - Catalyst thermal stress resistance evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Catalyst thermal stress resistance... Gaseous Exhaust Test Procedures § 90.427 Catalyst thermal stress resistance evaluation. (a) The purpose of the evaluation procedure specified in this section is to determine the effect of thermal stress on...

  13. 48 CFR 813.106 - Soliciting competition, evaluation of quotations or offers, award and documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Soliciting competition, evaluation of quotations or offers, award and documentation. 813.106 Section 813.106 Federal Acquisition... ACQUISITION PROCEDURES Procedures 813.106 Soliciting competition, evaluation of quotations or offers, award...

  14. 48 CFR 1313.106 - Soliciting competition, evaluation of quotations or offers, award and documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Soliciting competition, evaluation of quotations or offers, award and documentation. 1313.106 Section 1313.106 Federal Acquisition... PROCEDURES Procedures 1313.106 Soliciting competition, evaluation of quotations or offers, award and...

  15. 48 CFR 13.106 - Soliciting competition, evaluation of quotations or offers, award and documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Soliciting competition, evaluation of quotations or offers, award and documentation. 13.106 Section 13.106 Federal Acquisition... ACQUISITION PROCEDURES Procedures 13.106 Soliciting competition, evaluation of quotations or offers, award and...

  16. A Self-Assessment Procedure for Use in Evaluation Training

    ERIC Educational Resources Information Center

    Stufflebeam, Daniel L.; Wingate, Lori A.

    2005-01-01

    This article describes the Self-Assessment of Program Evaluation Expertise instrument and procedure developed to help participants assess their learning gains in a 3-week evaluation institute. Participants completed the instrument in a pre- and posttest format. To reduce both the threat of embarrassment from individual results and the temptation…

  17. 40 CFR 90.427 - Catalyst thermal stress resistance evaluation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Catalyst thermal stress resistance... Gaseous Exhaust Test Procedures § 90.427 Catalyst thermal stress resistance evaluation. (a) The purpose of the evaluation procedure specified in this section is to determine the effect of thermal stress on...

  18. 40 CFR 90.427 - Catalyst thermal stress resistance evaluation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Catalyst thermal stress resistance... Gaseous Exhaust Test Procedures § 90.427 Catalyst thermal stress resistance evaluation. (a) The purpose of the evaluation procedure specified in this section is to determine the effect of thermal stress on...

  19. 40 CFR 90.427 - Catalyst thermal stress resistance evaluation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Catalyst thermal stress resistance... Gaseous Exhaust Test Procedures § 90.427 Catalyst thermal stress resistance evaluation. (a) The purpose of the evaluation procedure specified in this section is to determine the effect of thermal stress on...

  20. Cost Analysis for Educational Program Evaluation.

    ERIC Educational Resources Information Center

    Haller, Emil J.

    Concerned with the problem of determining program costs as part of the evaluation process, this article helps the practitioner arrive at useful conceptions of the term "cost" and procedures for assessing the costs of an educational program. Its purpose is to help design costing procedures for evaluation situations that are commonly encountered. An…

  1. 40 CFR 90.427 - Catalyst thermal stress resistance evaluation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Catalyst thermal stress resistance... Gaseous Exhaust Test Procedures § 90.427 Catalyst thermal stress resistance evaluation. (a) The purpose of the evaluation procedure specified in this section is to determine the effect of thermal stress on...

  2. Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnette, Daniel Wayne

    This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less

  3. Trends, Predictors, and Outcomes of Healthcare Resources Used in Patients Hospitalized with Alzheimer's Disease with at Least One Procedure: The Nationwide Inpatient Sample.

    PubMed

    Beydoun, May A; Gamaldo, Alyssa A; Beydoun, Hind A; Shaked, Danielle; Zonderman, Alan B; Eid, Shaker M

    2017-01-01

    We assessed trends, predictors and outcomes of resource utilization in hospital inpatient discharges with a principal diagnosis of Alzheimer's disease (AD) with at least one procedure. Using Nationwide Inpatient Sample data (NIS, 2002-2012), discharges primarily diagnosed with AD, aged ≥60 y and with ≥1 procedure, were selected (Weighted N = 92,300). Hospital resource utilization were assessed using ICD-9-CM codes, while hospitalization outcomes included total charges (TC, 2012$), length of stay (LOS, days), and mortality risk (MR, %). Brain and respiratory/gastrointestinal procedure utilization both dropped annually by 3-7%, while cardiovascular procedures/evaluations, blood evaluations, blood transfusion, and resuscitation ("CVD/Blood") as well as neurophysiological and psychological evaluation and treatment ("Neuro") procedures increased by 5-8%. Total charges, length of stay, and mortality risk were all markedly higher with use of respiratory/gastrointestinal procedures as opposed to being reduced with use of "Brain" procedures. Procedure count was positively associated with all three hospitalization outcomes. In sum, patterns of hospital resources that were used among AD inpatients changed over-time, and were associated with hospitalization outcomes such as total charges, length of stay, and mortality risk.

  4. Evaluation of a Blocked-Trials Procedure to Establish Complex Stimulus Control over Intraverbal Responses in Children with Autism

    ERIC Educational Resources Information Center

    Ingvarsson, Einar T.; Kramer, Rachel L.; Carp, Charlotte L.; Pétursdóttir, Anna I.; Macias, Heather

    2016-01-01

    We evaluated the use of a blocked-trials procedure to establish complex stimulus control over intraverbal responses. The participants were four young boys with a diagnosis of autism who had struggled to master intraverbals. The blocked-trials procedures involved presentation of stimuli in separate trial blocks. The trial blocks gradually reduced…

  5. Evaluation of Graduated vs All-or-None Contingencies on Rate Tasks for Individuals Diagnosed with Autism

    ERIC Educational Resources Information Center

    Kassardjian, Alyne; Leaf, Jeremy A.; Leaf, Justin B.; Townley-Cochran, Donna; Alcalay, Aditt; Milne, Christine; Dale, Stephanie; Tsuji, Kathleen; Leaf, Ronald; Taubman, Mitchell; McEachin, John

    2016-01-01

    The graduated reinforcement procedure (also known as differential reinforcement) is an often-used procedure in the field of Applied Behavior Analysis to teach new skills and increase pro-social behaviors. In this study, the researchers used a multi-element design to evaluated the graduated reinforcement procedure for six children with a diagnosis…

  6. The use of high-fidelity human patient simulation as an evaluative tool in the development of clinical research protocols and procedures.

    PubMed

    Wright, Melanie C; Taekman, Jeffrey M; Barber, Linda; Hobbs, Gene; Newman, Mark F; Stafford-Smith, Mark

    2005-12-01

    Errors in clinical research can be costly, in terms of patient safety, data integrity, and data collection. Data inaccuracy in early subjects of a clinical study may be associated with problems in the design of the protocol, procedures, and data collection tools. High-fidelity patient simulation centers provide an ideal environment to apply human-centered design to clinical trial development. A draft of a complex clinical protocol was designed, evaluated and modified using a high-fidelity human patient simulator in the Duke University Human Simulation and Patient Safety Center. The process included walk-throughs, detailed modifications of the protocol and development of procedural aids. Training of monitors and coordinators provided an opportunity for observation of performance that was used to identify further improvements to the protocol. Evaluative steps were used to design the research protocol and procedures. Iterative modifications were made to the protocol and data collection tools. The success in use of human simulation in the preparation of a complex clinical drug trial suggests the benefits of human patient simulation extend beyond training and medical equipment evaluation. Human patient simulation can provide a context for informal expert evaluation of clinical protocol design and for formal "rehearsal" to evaluate the efficacy of procedures and support tools.

  7. The evaluation of a new apheresis device for automated red blood cell exchange procedures in patients with sickle cell disease.

    PubMed

    Quirolo, Keith; Bertolone, Salvatore; Hassell, Kathryn; Howard, Thomas; King, Karen E; Rhodes, Diane K; Bill, Jerry

    2015-04-01

    The Spectra Optia apheresis system (SO), a blood component separator, can be used to perform red blood cell exchange (RBCX) procedures for the transfusion management of sickle cell disease (SCD) in adults and children. This study was designed to evaluate the performance of the SO RBCX protocols (exchange and depletion/exchange) in patients with SCD. Patients with SCD and a need for an RBCX procedure as part of a chronic program or as a single procedure were enrolled in this multicenter, single-arm, open-label study. The primary goal of the study was to confirm that the predicted percentage of the patient's original RBCs remaining at the end of the procedure (FCRp) reflects the actual cell fraction remaining, as measured by %HbS (FCRa). Secondary endpoints included ability of the SO to achieve the desired final hematocrit (Hct) and device-related serious adverse events (SAEs). Seventy-two patients 12 years of age or older were enrolled in the study; 60 were evaluable. The ratio of FCRa to FCRp after the RBCX procedure was 0.90, well within the prespecified range of 0.75 to 1.25. The SO was able to achieve the desired final Hct in the evaluable population. The safety profile was favorable, and no patients had an SAE or unexpected adverse device effect or withdrew from the procedure or treatment due to an adverse event. The SO performed effectively and safely for both the RBCX procedure and the RBCX depletion/exchange procedure. © 2014 AABB.

  8. Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

    PubMed

    Ruiz-Cruces, R; Vano, E; Carrera-Magariño, F; Moreno-Rodriguez, F; Soler-Cantos, M M; Canis-Lopez, M; Hernández-Armas, J; Diaz-Romero, F J; Rosales-Espizua, F; Fernandez-Soto, J M; Sanchez-Casanueva, R; Martin-Palanca, A; Perez-Martinez, M; Gil-Agudo, A; Zarca-Diaz, M A; Parra-Osorio, V; Muñoz Ruiz-Canela, J J; Moreno-Sanchez, T; Lopez-Medina, A; Moreno-Saiz, C; Galan-Montenegro, P; Gallego-Beuter, J J; Gonzalez-de-Garay, M; Zapata-Jimenez, J C; Pastor-Vega, J M; Cañete, S

    2016-12-01

    To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. The KAP (3rd quartile) in Gy cm 2 for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. • National DRLs for interventional procedures have been proposed given level of complexity • For clinical audits, the level of complexity should be taken into account. • An evaluation of the complexity levels of the procedure should be made.

  9. How to Modify (Implicit) Evaluations of Fear-Related Stimuli: Effects of Feature-Specific Attention Allocation

    PubMed Central

    Vanaelst, Jolien; Spruyt, Adriaan; De Houwer, Jan

    2016-01-01

    We demonstrate that feature-specific attention allocation influences the way in which repeated exposure modulates implicit and explicit evaluations toward fear-related stimuli. During an exposure procedure, participants were encouraged to assign selective attention either to the evaluative meaning (i.e., Evaluative Condition) or a non-evaluative, semantic feature (i.e., Semantic Condition) of fear-related stimuli. The influence of the exposure procedure was captured by means of a measure of implicit evaluation, explicit evaluative ratings, and a measure of automatic approach/avoidance tendencies. As predicted, the implicit measure of evaluation revealed a reduced expression of evaluations in the Semantic Condition as compared to the Evaluative Condition. Moreover, this effect generalized toward novel objects that were never presented during the exposure procedure. The explicit measure of evaluation mimicked this effect, although it failed to reach conventional levels of statistical significance. No effects were found in terms of automatic approach/avoidance tendencies. Potential implications for the treatment of anxiety disorders are discussed. PMID:27242626

  10. How to Modify (Implicit) Evaluations of Fear-Related Stimuli: Effects of Feature-Specific Attention Allocation.

    PubMed

    Vanaelst, Jolien; Spruyt, Adriaan; De Houwer, Jan

    2016-01-01

    We demonstrate that feature-specific attention allocation influences the way in which repeated exposure modulates implicit and explicit evaluations toward fear-related stimuli. During an exposure procedure, participants were encouraged to assign selective attention either to the evaluative meaning (i.e., Evaluative Condition) or a non-evaluative, semantic feature (i.e., Semantic Condition) of fear-related stimuli. The influence of the exposure procedure was captured by means of a measure of implicit evaluation, explicit evaluative ratings, and a measure of automatic approach/avoidance tendencies. As predicted, the implicit measure of evaluation revealed a reduced expression of evaluations in the Semantic Condition as compared to the Evaluative Condition. Moreover, this effect generalized toward novel objects that were never presented during the exposure procedure. The explicit measure of evaluation mimicked this effect, although it failed to reach conventional levels of statistical significance. No effects were found in terms of automatic approach/avoidance tendencies. Potential implications for the treatment of anxiety disorders are discussed.

  11. Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial.

    PubMed

    Rouchy, R C; Moreau-Gaudry, A; Chipon, E; Aubry, S; Pazart, L; Lapuyade, B; Durand, M; Hajjam, M; Pottier, S; Renard, B; Logier, R; Orry, X; Cherifi, A; Quehen, E; Kervio, G; Favelle, O; Patat, F; De Kerviler, E; Hughes, C; Medici, M; Ghelfi, J; Mounier, A; Bricault, I

    2017-07-06

    Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.

  12. A study for high accuracy measurement of residual stress by deep hole drilling technique

    NASA Astrophysics Data System (ADS)

    Kitano, Houichi; Okano, Shigetaka; Mochizuki, Masahito

    2012-08-01

    The deep hole drilling technique (DHD) received much attention in recent years as a method for measuring through-thickness residual stresses. However, some accuracy problems occur when residual stress evaluation is performed by the DHD technique. One of the reasons is that the traditional DHD evaluation formula applies to the plane stress condition. The second is that the effects of the plastic deformation produced in the drilling process and the deformation produced in the trepanning process are ignored. In this study, a modified evaluation formula, which is applied to the plane strain condition, is proposed. In addition, a new procedure is proposed which can consider the effects of the deformation produced in the DHD process by investigating the effects in detail by finite element (FE) analysis. Then, the evaluation results obtained by the new procedure are compared with that obtained by traditional DHD procedure by FE analysis. As a result, the new procedure evaluates the residual stress fields better than the traditional DHD procedure when the measuring object is thick enough that the stress condition can be assumed as the plane strain condition as in the model used in this study.

  13. CBP for Field Workers – Results and Insights from Three Usability and Interface Design Evaluations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oxstrand, Johanna Helene; Le Blanc, Katya Lee; Bly, Aaron Douglas

    2015-09-01

    Nearly all activities that involve human interaction with the systems in a nuclear power plant are guided by procedures. Even though the paper-based procedures (PBPs) currently used by industry have a demonstrated history of ensuring safety, improving procedure use could yield significant savings in increased efficiency as well as improved nuclear safety through human performance gains. The nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. As a step toward the goal of improving procedure use and adherence, researchers in the Light-Water Reactor Sustainability (LWRS) Program, togethermore » with the nuclear industry, have been investigating the possibility and feasibility of replacing the current paper-based procedure process with a computer-based procedure (CBP) system. This report describes a field evaluation of new design concepts of a prototype computer-based procedure system.« less

  14. Standardization of carbon-phenolic composite test methodology

    NASA Technical Reports Server (NTRS)

    Hall, W. B.

    1986-01-01

    The objective of this study was to evaluate the residual volatiles, filler content, and resin flow test procedures for carbon-phenolic prepreg materials. The residual volatile test procedure was rewritten with tighter procedure control which was then evaluated by round robin testing by four laboratories on the same rolls of prepreg. Results indicated that the residual volatiles test was too operator and equipment dependent to be reliable, and it was recommended that the test be discontinued. The resin flow test procedures were rewritten with tighter procedure control, and it is now considered to be an acceptable test. It was recommended that the filler content determination be made prior to prepregging.

  15. Language and arithmetic--a study using the intracarotid amobarbital procedure.

    PubMed

    Delazer, Margarete; Karner, Elfriede; Unterberger, Iris; Walser, Gerald; Waldenberger, Peter; Trinka, Eugen; Benke, Thomas

    2005-08-22

    The intracarotid amobarbital procedure is used as a standard procedure in presurgical evaluation to assess hemispheric lateralization of language and memory, but has not been applied to investigate numerical processing. Patients with medically intractable epilepsy (n=20) were consecutively recruited during a presurgical evaluation programme. All 14 patients with left-lateralized language showed better arithmetic performance with the left hemisphere (intracarotid amobarbital procedure right), while five out of six patients with bilateral or right-hemispheric language representation showed better performance with the right hemisphere (intracarotid amobarbital procedure left). Furthermore, in patients with left-lateralized language, an interaction between intracarotid amobarbital procedure and type of arithmetic operation was found. The study suggests a close association between language lateralization and hemispheric specialization for arithmetic processing.

  16. Assessment of Anatomical Knowledge and Core Trauma Competency Vascular Skills.

    PubMed

    Granite, Guinevere; Pugh, Kristy; Chen, Hegang; Longinaker, Nyaradzo; Garofalo, Evan; Shackelford, Stacy; Shalin, Valerie; Puche, Adam; Pasley, Jason; Sarani, Babak; Henry, Sharon; Bowyer, Mark; Mackenzie, Colin

    2018-03-01

    Surgical residents express confidence in performing specific vascular exposures before training, but such self-reported confidence did not correlate with co-located evaluator ratings. This study reports residents' self-confidence evaluated before and after Advanced Surgical Skills for Exposure in Trauma (ASSET) cadaver-based training, and 12-18 mo later. We hypothesize that residents will better judge their own skill after ASSET than before when compared with evaluator ratings. Forty PGY2-7 surgical residents performed four procedures: axillary artery (AA), brachial artery (BA), femoral artery exposure and control (FA), and lower extremity fasciotomy (FAS) at the three evaluations. Using 5-point Likert scales, surgeons self-assessed their confidence in anatomical understanding and procedure performance after each procedure and evaluators rated each surgeon accordingly. For all the three evaluations, residents consistently rated their anatomical understanding (p < 0.04) and surgical performance (p < 0.03) higher than evaluators for both FA and FAS. Residents rated their anatomical understanding and surgical performance higher (p < 0.005) than evaluators for BA after training and up to 18 mo later. Only for third AA evaluation were there no rating differences. Residents overrate their anatomical understanding and performance abilities for BA, FA, and FAS even after performing the procedures and being debriefed three times in 18 mo.

  17. 34 CFR 303.342 - Procedures for IFSP development, review, and evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... development, review, and evaluation. (a) Meeting to develop initial IFSP—timelines. For a child who has been... 34 Education 2 2010-07-01 2010-07-01 false Procedures for IFSP development, review, and evaluation... PROGRAM FOR INFANTS AND TODDLERS WITH DISABILITIES Program and Service Components of a Statewide System of...

  18. 34 CFR 303.342 - Procedures for IFSP development, review, and evaluation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... development, review, and evaluation. (a) Meeting to develop initial IFSP—timelines. For a child who has been... 34 Education 2 2011-07-01 2010-07-01 true Procedures for IFSP development, review, and evaluation... PROGRAM FOR INFANTS AND TODDLERS WITH DISABILITIES Program and Service Components of a Statewide System of...

  19. Maintenance Procedure Display: Head Mounted Display (HMD) Evaluations

    NASA Technical Reports Server (NTRS)

    Whitmore, Milrian; Litaker, Harry L., Jr.; Solem, Jody A.; Holden, Kritina L.; Hoffman, Ronald R.

    2007-01-01

    A viewgraph presentation describing maintenance procedures for head mounted displays is shown. The topics include: 1) Study Goals; 2) Near Eye Displays (HMDs); 3) Design; 4) Phase I-Evaluation Methods; 5) Phase 1 Results; 6) Improved HMD Mounting; 7) Phase 2 -Evaluation Methods; 8) Phase 2 Preliminary Results; and 9) Next Steps.

  20. Evaluating the Bookmark Judgments of Standard-Setting Panelists

    ERIC Educational Resources Information Center

    Engelhard, George, Jr.

    2011-01-01

    The purpose of this study is to describe a new approach for evaluating the judgments of standard-setting panelists within the context of the bookmark procedure. The bookmark procedure is widely used for setting performance standards on high-stakes assessments. A many-faceted Rasch (MFR) model is proposed for evaluating the bookmark judgments of…

  1. Engineering flight and guest pilot evaluation report, phase 2. [DC 8 aircraft

    NASA Technical Reports Server (NTRS)

    Morrison, J. A.; Anderson, E. B.; Brown, G. W.; Schwind, G. K.

    1974-01-01

    Prior to the flight evaluation, the two-segment profile capabilities of the DC-8-61 were evaluated and flight procedures were developed in a flight simulator at the UA Flight Training Center in Denver, Colorado. The flight evaluation reported was conducted to determine the validity of the simulation results, further develop the procedures and use of the area navigation system in the terminal area, certify the system for line operation, and obtain evaluations of the system and procedures by a number of pilots from the industry. The full area navigation capabilities of the special equipment installed were developed to provide terminal area guidance for two-segment approaches. The objectives of this evaluation were: (1) perform an engineering flight evaluation sufficient to certify the two-segment system for the six-month in-service evaluation; (2) evaluate the suitability of a modified RNAV system for flying two-segment approaches; and (3) provide evaluation of the two-segment approach by management and line pilots.

  2. 34 CFR 75.224 - What are the procedures for using a multiple tier review process to evaluate applications?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false What are the procedures for using a multiple tier... applications received. (d) The Secretary may, in any tier— (1) Use more than one group of experts to gain... procedures for using a multiple tier review process to evaluate applications? (a) The Secretary may use a...

  3. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in section 4.3.1 of this appendix. 3.2.7PM2.5 Performance Evaluation Program (PEP) Procedures. The... evaluation audit means that both the primary monitor and PEP audit concentrations are valid and above 3 µg/m3... Evaluation Program (PEP) Procedures. Each year, one performance evaluation audit, as described in section 3.2...

  4. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... in section 4.3.1 of this appendix. 3.2.7PM2.5 Performance Evaluation Program (PEP) Procedures. The... evaluation audit means that both the primary monitor and PEP audit concentrations are valid and above 3 µg/m3... Evaluation Program (PEP) Procedures. Each year, one performance evaluation audit, as described in section 3.2...

  5. Evaluating Internal Communication: The ICA Communication Audit.

    ERIC Educational Resources Information Center

    Goldhaber, Gerald M.

    1978-01-01

    The ICA Communication Audit is described in detail as an effective measurement procedure that can help an academic institution to evaluate its internal communication system. Tools, computer programs, analysis, and feedback procedures are described and illustrated. (JMF)

  6. [Evaluation of ergonomic load of clinical nursing procedures].

    PubMed

    Yan, P; Zhang, L; Li, F Y; Yang, Y; Wang, Y N; Huang, A M; Dai, Y L; Yao, H

    2017-08-20

    Objective: To evaluate the ergonomic load of clinical nursing procedures and to provide evidence for the prevention and management of work-related musculoskeletal disorders (WMSDs) in nurses. Methods: Based on the nursing unit characteristics and the common departments involving patient-turning procedures, 552 nurses were selected from 6 clinical departments from July to September, 2016. The ergonomic load of four types of patient-turning procedures, i.e., turning the patient's body, changing the bed linen of in-bed patients, moving patients, and chest physiotherapy, was evaluated by the on-site inspectors and self-evaluated by the operators using the Quick Exposure Check. The exposure value, exposure level, and exposure rate of WMSDs were assessed based on the procedure-related physical loads on the back, shoulders/arms, wrists/hands and neck, as well as the loads from work rhythm and work pressure. Results: All surveyed subjects were females who were aged mostly between 26-30 years (49.46%) , with a mean age of 29.66±5.28 years. These nurses were mainly from the Department of Infection (28.99%) and Spine Surgery (21.56%) . There were significant differences in the back, shoulders/arms, neck, work rhythm, and work pressure scores between different nursing procedures ( F =16.613, 5.884, 3.431, 3.222, and 5.085, respectively; P <0.05) . Patient-turning nursing procedures resulted in high to intermediate physical load in nurses. Procedures with high to low level of WMSDs exposure were patient turning (72.69%) , bed linen changing (67.15%) , patient transfer (65.82%) , and chest physiotherapy (58.34%) . In particular, patient turning was considered as very high-risk procedure, whereas others were considered as high-risk procedures. Conclusion: Patient-turning nursing procedures result in high ergonomic load in the operators. Therefore, more focus should be placed on the ergonomics of the caretakers and nurses.

  7. Software support in automation of medicinal product evaluations.

    PubMed

    Juric, Radmila; Shojanoori, Reza; Slevin, Lindi; Williams, Stephen

    2005-01-01

    Medicinal product evaluation is one of the most important tasks undertaken by government health departments and their regulatory authorities, in every country in the world. The automation and adequate software support are critical tasks that can improve the efficiency and interoperation of regulatory systems across the world. In this paper we propose a software solution that supports the automation of the (i) submission of licensing applications, and (ii) evaluations of submitted licensing applications, according to regulatory authorities' procedures. The novelty of our solution is in allowing licensing applications to be submitted in any country in the world and evaluated according to any evaluation procedure (which can be chosen by either regulatory authorities or pharmaceutical companies). Consequently, submission and evaluation procedures become interoperable and the associated data repositories/databases can be shared between various countries and regulatory authorities.

  8. [Evaluation of pain during mobilization and endotracheal aspiration in critical patients].

    PubMed

    Robleda, G; Roche-Campo, F; Membrilla-Martínez, L; Fernández-Lucio, A; Villamor-Vázquez, M; Merten, A; Gich, I; Mancebo, J; Català-Puigbó, E; Baños, J E

    2016-03-01

    1) To assess the prevalence of pain during nursing care procedures, and 2) to evaluate the usefulness of certain vital signs and the bispectral index (BIS) in detecting pain. A prospective, observational analytical study was made of procedures (endotracheal aspiration and mobilization with turning) in critically ill sedated patients on mechanical ventilation. The Behavioral Pain Scale was used to assess pain, with scores of ≥3 indicating pain. Various physiological signs and BIS values were recorded, with changes of >10% being considered clinically relevant. A total of 146 procedures in 70 patients were analyzed. Pain prevalence during the procedures was 94%. Vital signs and BIS values increased significantly during the procedures compared to resting conditions, but only the changes in BIS were considered clinically relevant. In the subgroup of patients receiving preemptive analgesia prior to the procedure, pain decreased significantly compared to the group of patients who received no such analgesia (-2 [IQR: {-5}-0] vs. 3 [IQR: 1-4]; P<.001, respectively). The procedures evaluated in this study are painful. Changes in vital signs are not good indicators of pain. Changes in BIS may provide useful information about pain, but more research is needed. The administration of preemptive analgesia decreases pain during the procedures. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  9. Evaluation of prototype air carrier instrument approach procedure charts.

    DOT National Transportation Integrated Search

    1995-07-31

    The objective of this study was to evaluate the design features of two prototype Instrument Approach Procedure (IAP) charts. The John A. Volpe National Transportation System's Center in cooperation with the Air Transport Association's Chart and Data ...

  10. Transit Station Renovation: A Case Study of Planning and Design Procedures

    DOT National Transportation Integrated Search

    1979-06-01

    The general techniques and procedures for planning and evaluating transit : interface facilities are applied comprehensively to the problem of station : renovation. The 69th Street Terminal in Philadelphia is evaluated in terms of : its performance i...

  11. Estimating Commercial Truck VMT of Interstate Motor Carriers: Data Evaluation

    DOT National Transportation Integrated Search

    1989-11-01

    The objectives of this study were to document and evaluate existing data sources and procedures that estimate the VMT (vehicle miles traveled) of commercial vehicles operating in interstate commerce; to recommend and develop the best procedures that ...

  12. Bus service evaluation procedures : a review

    DOT National Transportation Integrated Search

    1979-03-01

    The report presents the results of a literature review and survey of 71 transit properties in the U. S. and Canada regarding bus service evaluation procedures currently in use. The focus of the study was to identify service performance indicators and...

  13. Procedures for evaluating corrosion-inhibiting admixtures for structural concrete

    DOT National Transportation Integrated Search

    2000-06-01

    The objectives of this research were to (1) develop procedures for evaluating and qualifying corrosion-inhibiting admixtures (CIAs) and (2) recommend performance criteria for their acceptance. Phase I work included a literature review of CIAs, the re...

  14. Antimicrobial Testing Methods & Procedures: MB-10-06

    EPA Pesticide Factsheets

    Describes the procedures used to log-in, prepare, and evaluate the quality of media and reagents used in microbiological assays by the Microbiology Laboratory Branch (MLB), for use in the quality evaluation of media and reagents used by MLB.

  15. Standard Evaluation Procedures (SEPs) and Data Entry Spreadsheet Templates (DESTs) for Endocrine Disruptor Screening Program (EDSP) Tier 1 Assays

    EPA Pesticide Factsheets

    This page provides information and access to Standard Evaluation Procedures (SEPs) and Data Entry Spreadsheet Templates (DESTs) developed by EPA's Office of Chemical Safety and Pollution Prevention (OCSPP).

  16. Evaluation of prototype air carrier instrument approach procedure charts

    DOT National Transportation Integrated Search

    1995-07-01

    The objective of this study was to evaluate the design features of two prototype Instrument Approach Procedure (IAP) charts. The John A. Volpe National Transportation Systems Center in cooperation with the Air Transport Association's Chart and Data D...

  17. Evaluation of DOTD's Existing Queue Estimation Procedures : Research Project Capsule

    DOT National Transportation Integrated Search

    2017-10-01

    The primary objective of this study is to evaluate the effectiveness of DOTDs queue estimation procedures by comparing results with those obtained directly from site observations through video camera footage or other means. Actual queue start time...

  18. Trackless tack coat materials : a laboratory evaluation performance acceptance.

    DOT National Transportation Integrated Search

    2012-06-01

    The purpose of this study was to develop, demonstrate, and document laboratory procedures that could be used by the : Virginia Department of Transportation (VDOT) to evaluate non-tracking tack coat materials. The procedures would be used to : qualify...

  19. Application of ATC/DDD methodology to evaluate perioperative antimicrobial prophylaxis.

    PubMed

    Akalin, Serife; Kutlu, Selda Sayin; Cirak, Bayram; Eskiçorapcı, Saadettin Yilmaz; Bagdatli, Dilek; Akkaya, Semih

    2012-02-01

    To evaluate quality of perioperative antibiotic prophylaxis (PAP) and to calculate the cost per procedure in a Turkish university hospital. A 352-bed teaching hospital in Denizli, Turkey. An prospective audit was performed between July and October 2010. All clean, clean-contaminated and contaminated elective surgical procedures in ten surgical wards were recorded. Antimicrobial use was calculated per procedure using the ATC-DDD system. The appropriateness of antibiotic use for each procedure was evaluated according to international guidelines on PAP. In addition, the cost per procedure was calculated. Overall, in 577 of the 625 (92.3%) of the studied procedures, PAP was used. PAP was indicated in 12.5% of the group where it was not used, and not indicated in 7.1% of the group where it was used. Unnecessarily prolonged antimicrobial prophylaxis was observed in 56.9% of the procedures, mean duration was 2.6 ± 2.7 days. The most frequently used antimicrobials were cefazolin (117.9 DDD/100-operation) and sulbactam/ampicillin (102.2 DDD/100-operation). The timing of the starting dose was appropriate in 545 procedures (94.5%). In the group that received PAP, only 80 (13.7%) of the procedures were found to be fully appropriate and correct. The density of antimicrobial use per operation was 2.8 DDD. The mean cost of the use of prophylactic antimicrobials 18.6 per procedure. The density of antimicrobial use in PAP was found to be very high in our hospital. Antibiotic overuse extended into the postoperative period.

  20. Sodium pentothal hypnosis: a procedure for evaluating medical patients with suspected psychiatric co-morbidity.

    PubMed

    Russo, M B; Brooks, F R; Fontenot, J P; Dopler, B M; Neely, E T; Halliday, A W

    1997-03-01

    The cases presented here were patients referred for neurologic disability evaluations. They met the three selection criteria presented and underwent the four-phase pentothal hypnosis procedure described and at the conclusion were diagnosed as having psychiatric morbidity. We recommend that the sodium pentothal hypnosis procedure be considered for use whenever there is concern for psychiatric co-morbidity in a patient with presumed physiologic disease.

  1. Laboratory Evaluation of Light Obscuration Particle Counters used to Establish use Limits for Aviation Fuel

    DTIC Science & Technology

    2015-12-01

    markings are indicated, follow agency authorization procedures , e.g. RD/FRD, PROPIN, ITAR, etc. Include copyright information. 13. SUPPLEMENTARY...Contamination in Distillate Fuels (Visual Inspection Procedures ), as a final check of fuel to ensure aviation fuel is clear and bright before flight...Laboratories at the Detroit Arsenal. The online procedure for evaluating the light obscuration particle counters was modified from the concepts found

  2. New Method for Evaluation of Virucidal Activity of Antiseptics and Disinfectants

    PubMed Central

    Papageorgiou, Georgios T.; Mocé-Llivina, Laura; Jofre, Juan

    2001-01-01

    Counting culturable viruses adsorbed to cellulose nitrate filters (the VIRADEN method) is proposed as a simple procedure for the evaluation of the virucidal activity of antiseptics and disinfectants. The virucidal activities of two different doses of iodine, chlorine, glutaraldehyde, and chlorhexidine digluconate on poliovirus 1 were tested with a standardized procedure and with the VIRADEN method. The two procedures assayed provided similar results. PMID:11722944

  3. An approach for assessing software prototypes

    NASA Technical Reports Server (NTRS)

    Church, V. E.; Card, D. N.; Agresti, W. W.; Jordan, Q. L.

    1986-01-01

    A procedure for evaluating a software prototype is presented. The need to assess the prototype itself arises from the use of prototyping to demonstrate the feasibility of a design or development stategy. The assessment procedure can also be of use in deciding whether to evolve a prototype into a complete system. The procedure consists of identifying evaluations criteria, defining alterative design approaches, and ranking the alternatives according to the criteria.

  4. Integrating Program Theory and Systems-Based Procedures in Program Evaluation: A Dynamic Approach to Evaluate Educational Programs

    ERIC Educational Resources Information Center

    Grammatikopoulos, Vasilis

    2012-01-01

    The current study attempts to integrate parts of program theory and systems-based procedures in educational program evaluation. The educational program that was implemented, called the "Early Steps" project, proposed that physical education can contribute to various educational goals apart from the usual motor skills improvement. Basic…

  5. Models and Procedures for Improving the Planning, Management, and Evaluation of Cooperative Education Programs. Final Report. Volume I.

    ERIC Educational Resources Information Center

    Blaschke, Charles L.; Steiger, JoAnn

    This report of a project to design a set of training guidelines for planning, managing, and evaluating cooperative education programs describes briefly the procedures used in developing the guidelines and model; discusses the various components of the planning, management, and evaluation process; and presents guidelines and criteria for designing…

  6. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation of...

  7. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  8. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  9. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  10. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  11. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation of...

  12. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  13. Test and analysis procedures for updating math models of Space Shuttle payloads

    NASA Technical Reports Server (NTRS)

    Craig, Roy R., Jr.

    1991-01-01

    Over the next decade or more, the Space Shuttle will continue to be the primary transportation system for delivering payloads to Earth orbit. Although a number of payloads have already been successfully carried by the Space Shuttle in the payload bay of the Orbiter vehicle, there continues to be a need for evaluation of the procedures used for verifying and updating the math models of the payloads. The verified payload math models is combined with an Orbiter math model for the coupled-loads analysis, which is required before any payload can fly. Several test procedures were employed for obtaining data for use in verifying payload math models and for carrying out the updating of the payload math models. Research was directed at the evaluation of test/update procedures for use in the verification of Space Shuttle payload math models. The following research tasks are summarized: (1) a study of free-interface test procedures; (2) a literature survey and evaluation of model update procedures; and (3) the design and construction of a laboratory payload simulator.

  14. A quasi randomized-controlled trial to evaluate the effectiveness of clowntherapy on children's anxiety and pain levels in emergency department.

    PubMed

    Felluga, Margherita; Rabach, Ingrid; Minute, Marta; Montico, Marcella; Giorgi, Rita; Lonciari, Isabella; Taddio, Andrea; Barbi, Egidio

    2016-05-01

    The aim of the study is to investigate if the presence of medical clowns during painful procedures in the emergency department (ED) affects children's anxiety and pain. Forty children (4-11 years) admitted to the ED with the need of painful procedures were prospectively enrolled. They were randomly assigned to the clown group, where children interacted with clowns or to the control group in which they were entertained by parents and ED nurses. The children's anxiety was assessed by the Children's Anxiety and Pain Scales; pain was evaluated with the Numerical Rating Scale and Wong-Backer Scale, according to the children's age. Staff and clown's opinions were evaluated by means of dedicated questionnaires. Children's anxiety levels in the clown group were significantly lower than those compared with the control group, while children's pain levels did not change between the two groups. The presence of clowns in the ED before and during painful procedures was effective in reducing children's anxiety. • Anxiety and fear caused by medical procedures exacerbate children's pain and may interfere with the procedure. • To reduce anxiety, fear, and pain and to facilitate patient's evaluation, different non-pharmacological approaches have been proposed and positive effects of laughter and humor have been reported. What is New: • The presence of clowns in the waiting room and in the ED during medical evaluation and painful procedures helps to reduce children's anxiety.

  15. Improving child protection: a systematic review of training and procedural interventions.

    PubMed

    Carter, Y H; Bannon, M J; Limbert, C; Docherty, A; Barlow, J

    2006-09-01

    To synthesise published evidence regarding the effectiveness of training and procedural interventions aimed at improving the identification and management of child abuse and neglect by health professionals. Systematic review for the period 1994 to 2005 of studies that evaluated child protection training and procedural interventions. Main outcome measures were learning achievement, attitudinal change, and clinical behaviour. Seven papers that examined the effectiveness of procedural interventions and 15 papers that evaluated training programmes met the inclusion criteria. Critical appraisal showed that evaluation of interventions was on the whole poor. It was found that certain procedural interventions (such as the use of checklists and structured forms) can result in improved recording of important clinical information and may also alert clinical staff to the possibility of abuse. While a variety of innovative training programmes were identified, there was an absence of rigorous evaluation of their impact. However a small number of one-group pre- and post-studies suggest improvements in a range of attitudes necessary for successful engagement in the child protection process. Current evidence supports the use of procedural changes that improve the documentation of suspected child maltreatment and that enhance professional awareness. The lack of an evidence based approach to the implementation of child protection training may restrict the ability of all health professionals to fulfil their role in the child protection process. Formal evaluation of a variety of models for the delivery of this training is urgently needed with subsequent dissemination of results that highlight those found to be most effective.

  16. Field evaluation of flight deck procedures for flying CTAS descents

    DOT National Transportation Integrated Search

    1997-01-01

    Flight deck descent procedures were developed for a field evaluation of the CTAS Descent Advisor conducted in the fall of 1995. During this study, CTAS descent clearances were issued to 185 commercial flights at Denver International Airport. Data col...

  17. Suggested Procedures For Evaluating The Effectiveness Of Freeway Hov Facilities

    DOT National Transportation Integrated Search

    1991-02-01

    THIS REPORT PRESENTS THE RESULTS OF THE STATE-OF-THE-ART REVIEW OF EVALUATION PRACTICES USED WITH DIFFERENT HIGH-OCCUPANCY VEHICLE (HOV) LANE PROJECTS IN NORTH AMERICA. BASED ON THIS REVIEW, SUGGESTED PROCEDURES ARE OUTLINED FOR CONDUCTING BEFORE-AND...

  18. Risk analysis of computer system designs

    NASA Technical Reports Server (NTRS)

    Vallone, A.

    1981-01-01

    Adverse events during implementation can affect final capabilities, schedule and cost of a computer system even though the system was accurately designed and evaluated. Risk analysis enables the manager to forecast the impact of those events and to timely ask for design revisions or contingency plans before making any decision. This paper presents a structured procedure for an effective risk analysis. The procedure identifies the required activities, separates subjective assessments from objective evaluations, and defines a risk measure to determine the analysis results. The procedure is consistent with the system design evaluation and enables a meaningful comparison among alternative designs.

  19. Development of an in vitro method for the evaluation of candidate repellents against Leptotrombidium (Acari: Trombiculidae) chiggers.

    PubMed

    Lerdthusnee, Kriangkrai; Khlaimanee, Nittaya; Monkanna, Taweesak; Mungviriya, Siriporn; Leepitakrat, Warisa; Debboun, Mustapha; Coleman, Russell E

    2003-01-01

    We developed a rapid and economical in vitro procedure with which to evaluate the efficacy of candidate repellents against chiggers. The procedure requires only 5 min and a small number of chiggers to obtain a valid estimate of the median effective dose. We used this procedure to evaluate the repellent activity of 11 compounds against the chigger, Leptotrombidium imphalum Vercammen-Grandjean and Langston. Median effective doses were determined for 10 of the 11 compounds. DM-165-2 (N,N-diethyl-3-flurobenzamide) was the only compound that was significantly more effective than deet.

  20. Diagnosis and ablation of multiform fascicular tachycardia.

    PubMed

    Sung, Raphael K; Kim, Albert M; Tseng, Zian H; Han, Frederick; Inada, Keiichi; Tedrow, Usha B; Viswanathan, Mohan N; Badhwar, Nitish; Varosy, Paul D; Tanel, Ronn; Olgin, Jeffrey E; Stephenson, William G; Scheinman, Melvin

    2013-03-01

    Fascicular tachycardia (FT) is an uncommon cause of monomorphic sustained ventricular tachycardia (VT). We describe 6 cases of FT with multiform QRS morphologies. Six of 823 consecutive VT cases were retrospectively analyzed and found attributable to FT with multiform QRS patterns, with 3 cases exhibiting narrow QRS VT as well. All underwent electrophysiology study including fascicular potential mapping, entrainment pacing, and electroanatomic mapping. The first 3 cases describe similar multiform VT patterns with successful ablation in the upper mid septum. Initially, a right bundle branch block (RBBB) VT with superior axis was induced. Radiofrequency catheter ablation (RFCA) targeting the left posterior fascicle (LPF) resulted in a second VT with RBBB inferior axis. RFCA in the upper septum just apical to the LBB potential abolished VT in all cases. Cases 4 and 5 showed RBBB VT with alternating fascicular block compatible with upper septal dependent VT, resulting in bundle branch reentrant VT (BBRT) after ablation of LPF and left anterior fascicle (LAF). Finally, Cases 5 and 6 demonstrated spontaneous shift in QRS morphology during VT, implicating participation of a third fascicle. In Case 6, successful ablation was achieved over the proximal LAF, likely representing insertion of the auxiliary fascicle near the proximal LAF. Multiform FTs show a reentrant mechanism using multiple fascicular branches. We hypothesize that retrograde conduction over the septal fascicle produces alternate fascicular patterns as well as narrow VT forms. Ablation of the respective fascicle was successful in abolishing FT but does not preclude development of BBRT unless septal fascicle is targeted and ablated. © 2012 Wiley Periodicals, Inc.

  1. Tracking hand movements captures the response dynamics of the evaluative priming effect.

    PubMed

    Kawakami, Naoaki; Miura, Emi

    2018-06-08

    We tested the response dynamics of the evaluative priming effect (i.e. facilitation of target responses following evaluatively congruent compared with evaluatively incongruent primes) using a mouse tracking procedure that records hand movements during the execution of categorisation tasks. In Experiment 1, when participants performed the evaluative categorisation task but not the non-evaluative semantic categorisation task, their mouse trajectories for evaluatively incongruent trials curved more toward the opposite response than those for evaluatively congruent trials, indicating the emergence of evaluative priming effects based on response competition. In Experiment 2, implementing a task-switching procedure in which evaluative and non-evaluative categorisation tasks were intermixed, we obtained reliable evaluative priming effects in the non-evaluative semantic categorisation task as well as in the evaluative categorisation task when participants assigned attention to the evaluative stimulus dimension. Analyses of hand movements revealed that the evaluative priming effects in the evaluative categorisation task were reflected in the mouse trajectories, while evaluative priming effects in the non-evaluative categorisation tasks were reflected in initiation times (i.e. the time elapsed between target onset and first mouse movement). Based on these findings, we discuss the methodological benefits of the mouse tracking procedure and the underlying processes of evaluative priming effects.

  2. 29 CFR 1956.21 - Procedures for submitting changes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Procedures for submitting changes. 1956.21 Section 1956.21 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION..., Change, Evaluation and Withdrawal of Approval Procedures § 1956.21 Procedures for submitting changes. The...

  3. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  4. 40 CFR 610.64 - Track test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Track test procedures. 610.64 Section 610.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.64 Track...

  5. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  6. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  7. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  8. 76 FR 47178 - Energy Efficiency Program: Test Procedure for Lighting Systems (Luminaires)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    ...: Test Procedure for Lighting Systems (Luminaires) AGENCY: Office of Energy Efficiency and Renewable... (``DOE'' or the ``Department'') is currently evaluating energy efficiency test procedures for luminaires... products. DOE recognizes that well-designed test procedures are important to produce reliable, repeatable...

  9. 23 CFR 630.1008 - State-level processes and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., data and information resources, training, and periodic evaluation enable a systematic approach for... management procedures. States should develop and implement systematic procedures to assess work zone impacts... practices and State processes and procedures. (e) Process review. In order to assess the effectiveness of...

  10. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  11. Evaluation and "PACE": A Study of Procedures and Effectiveness of Evaluation Sections in Approved PACE Project, with Recommendations for Improvement.

    ERIC Educational Resources Information Center

    Miller, Richard I.

    This report is based upon an analysis of the evaluation procedures outlined in 21 funded Title III proposals. The proposals were analyzed from a number of points of view. (1) Using the Stufflabeam model as a guide, they were examined to determine what, if any, provisions had been made for each of the four classes of evaluation: context, input,…

  12. 21 CFR 106.30 - Finished product evaluation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...

  13. 21 CFR 106.30 - Finished product evaluation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...

  14. 21 CFR 106.30 - Finished product evaluation.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...

  15. 21 CFR 106.30 - Finished product evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...

  16. Guide for Developing and Evaluating an SFAR 36 Engineering Procedures Manual

    DOT National Transportation Integrated Search

    1997-05-22

    This advisory circular (AC) sets forth an acceptable means, but not the only : means, for developing and evaluating a 14 Code of Federal Regulations (14CFR) : Special Federal Aviaton Regulation (SFAR)36 engineering procedures manual. As : such, the t...

  17. Evaluation of the FAA Advanced Flow Control Procedures.

    DOT National Transportation Integrated Search

    1972-01-01

    The report is an evaluation of the present FAA Advanced Flow Control Procedures (AFCP), based on data gathered from its implementation on February 5, 1971 and on a fast-time digital simulation of traffic feeding into the NY airports on that day. The ...

  18. Development, implementation and evaluation of a pedestrian safety zone for elderly pedestrians

    DOT National Transportation Integrated Search

    1998-02-01

    The objectives of this study were to develop and apply procedures for defining pedestrian safety zones for the older (age 65+) adult and to develop, implement and evaluate a countermeasure program in the defined zones. Zone definition procedures were...

  19. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  20. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  1. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  2. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  3. 10 CFR 205.282 - Evaluation of petition by the Office of Hearings and Appeals.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Evaluation of petition by the Office of Hearings and Appeals. 205.282 Section 205.282 Energy DEPARTMENT OF ENERGY OIL ADMINISTRATIVE PROCEDURES AND SANCTIONS Special Procedures for Distribution of Refunds § 205.282 Evaluation of petition by the Office of Hearings and Appeals. (a) After considering the...

  4. Evaluating the Effects of a Video Prompt in a System of Least Prompts Procedure

    ERIC Educational Resources Information Center

    Smith, Katie A.; Ayres, Kevin M.; Mechling, Linda C.; Alexander, Jennifer L.; Mataras, Theologia K.; Shepley, Sally B.

    2015-01-01

    The purpose of this study was to evaluate the effects of a system of least prompts procedure with a video prompt serving as the model in teaching office tasks to three high school students with moderate intellectual disability. A multiple probe across behaviors design replicated across participants was used to evaluate the intervention. The…

  5. Validity, reliability and support for implementation of independence-scaled procedural assessment in laparoscopic surgery.

    PubMed

    Kramp, Kelvin H; van Det, Marc J; Veeger, Nic J G M; Pierie, Jean-Pierre E N

    2016-06-01

    There is no widely used method to evaluate procedure-specific laparoscopic skills. The first aim of this study was to develop a procedure-based assessment method. The second aim was to compare its validity, reliability and feasibility with currently available global rating scales (GRSs). An independence-scaled procedural assessment was created by linking the procedural key steps of the laparoscopic cholecystectomy to an independence scale. Subtitled and blinded videos of a novice, an intermediate and an almost competent trainee, were evaluated with GRSs (OSATS and GOALS) and the independence-scaled procedural assessment by seven surgeons, three senior trainees and six scrub nurses. Participants received a short introduction to the GRSs and independence-scaled procedural assessment before assessment. The validity was estimated with the Friedman and Wilcoxon test and the reliability with the intra-class correlation coefficient (ICC). A questionnaire was used to evaluate user opinion. Independence-scaled procedural assessment and GRS scores improved significantly with surgical experience (OSATS p = 0.001, GOALS p < 0.001, independence-scaled procedural assessment p < 0.001). The ICCs of the OSATS, GOALS and independence-scaled procedural assessment were 0.78, 0.74 and 0.84, respectively, among surgeons. The ICCs increased when the ratings of scrub nurses were added to those of the surgeons. The independence-scaled procedural assessment was not considered more of an administrative burden than the GRSs (p = 0.692). A procedural assessment created by combining procedural key steps to an independence scale is a valid, reliable and acceptable assessment instrument in surgery. In contrast to the GRSs, the reliability of the independence-scaled procedural assessment exceeded the threshold of 0.8, indicating that it can also be used for summative assessment. It furthermore seems that scrub nurses can assess the operative competence of surgical trainees.

  6. Utilizing formative evaluation to enhance the understanding of chemistry and the methods and procedures of science

    NASA Astrophysics Data System (ADS)

    Pizzini, Edward L.; Treagust, David F.; Cody, John

    The purpose of this study was to determine whether or not formative evaluation could facilitate goal attainment in a biochemistry course and produce desired learning outcomes consistently by altering course materials and/or instruction. Formative evaluation procedures included the administration of the Inorganic-Organic-Biological Chemistry Test Form 1974 and the Methods and Procedures of Science test to course participants over three consecutive years. A one group pretest-post-test design was used. The statistical analysis involved the use of the Wilcoxon matched-pairs signed-ranks test. The study involved 64 participants. The findings indicate that the use of formative evaluation can be effective in producing desired learning outcomes to facilitate goal attainment.

  7. 29 CFR 1956.20 - Procedures for submission, approval and rejection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Procedures for submission, approval and rejection. 1956.20 Section 1956.20 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... PLANS Approval, Change, Evaluation and Withdrawal of Approval Procedures § 1956.20 Procedures for...

  8. Cracking the code: the accuracy of coding shoulder procedures and the repercussions.

    PubMed

    Clement, N D; Murray, I R; Nie, Y X; McBirnie, J M

    2013-05-01

    Coding of patients' diagnosis and surgical procedures is subject to error levels of up to 40% with consequences on distribution of resources and financial recompense. Our aim was to explore and address reasons behind coding errors of shoulder diagnosis and surgical procedures and to evaluate a potential solution. A retrospective review of 100 patients who had undergone surgery was carried out. Coding errors were identified and the reasons explored. A coding proforma was designed to address these errors and was prospectively evaluated for 100 patients. The financial implications were also considered. Retrospective analysis revealed the correct primary diagnosis was assigned in 54 patients (54%) had an entirely correct diagnosis, and only 7 (7%) patients had a correct procedure code assigned. Coders identified indistinct clinical notes and poor clarity of procedure codes as reasons for errors. The proforma was significantly more likely to assign the correct diagnosis (odds ratio 18.2, p < 0.0001) and the correct procedure code (odds ratio 310.0, p < 0.0001). Using the proforma resulted in a £28,562 increase in revenue for the 100 patients evaluated relative to the income generated from the coding department. High error levels for coding are due to misinterpretation of notes and ambiguity of procedure codes. This can be addressed by allowing surgeons to assign the diagnosis and procedure using a simplified list that is passed directly to coding.

  9. State-of-the-practice : evaluation of sediment basin design, construction, maintenance, and inspection procedures.

    DOT National Transportation Integrated Search

    2012-08-01

    The following document is the summary of results from a survey that was conducted to evaluate the state-of-the-practice for sediment basin design, construction, maintenance, and inspection procedures by State Highway Agencies (SHAs) across the nation...

  10. State-of-the-practice : evaluation of sediment basin design, construction, maintenance, and inspection procedures.

    DOT National Transportation Integrated Search

    2012-08-01

    The following document is the summary of results from a survey that was conducted to evaluate : the state-of-the-practice for sediment basin design, construction, maintenance, and inspection : procedures by State Highway Agencies (SHAs) across the na...

  11. 14 CFR 150.33 - Evaluation of programs.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...

  12. 14 CFR 150.33 - Evaluation of programs.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...

  13. 14 CFR 150.33 - Evaluation of programs.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...

  14. 14 CFR 150.33 - Evaluation of programs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...

  15. 14 CFR 150.33 - Evaluation of programs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...

  16. Evaluating the utility of 3D TRUS image information in guiding intra-procedure registration for motion compensation

    NASA Astrophysics Data System (ADS)

    De Silva, Tharindu; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-03-01

    In targeted 3D transrectal ultrasound (TRUS)-guided biopsy, patient and prostate movement during the procedure can cause target misalignments that hinder accurate sampling of pre-planned suspicious tissue locations. Multiple solutions have been proposed for motion compensation via registration of intra-procedural TRUS images to a baseline 3D TRUS image acquired at the beginning of the biopsy procedure. While 2D TRUS images are widely used for intra-procedural guidance, some solutions utilize richer intra-procedural images such as bi- or multi-planar TRUS or 3D TRUS, acquired by specialized probes. In this work, we measured the impact of such richer intra-procedural imaging on motion compensation accuracy, to evaluate the tradeoff between cost and complexity of intra-procedural imaging versus improved motion compensation. We acquired baseline and intra-procedural 3D TRUS images from 29 patients at standard sextant-template biopsy locations. We used the planes extracted from the 3D intra-procedural scans to simulate 2D and 3D information available in different clinically relevant scenarios for registration. The registration accuracy was evaluated by calculating the target registration error (TRE) using manually identified homologous fiducial markers (micro-calcifications). Our results indicate that TRE improves gradually when the number of intra-procedural imaging planes used in registration is increased. Full 3D TRUS information helps the registration algorithm to robustly converge to more accurate solutions. These results can also inform the design of a fail-safe workflow during motion compensation in a system using a tracked 2D TRUS probe, by prescribing rotational acquisitions that can be performed quickly and easily by the physician immediately prior to needle targeting.

  17. [Catheter-related bladder discomfort after urological surgery: importance of the type of surgery and efficiency of treatment by clonazepam].

    PubMed

    Maro, S; Zarattin, D; Baron, T; Bourez, S; de la Taille, A; Salomon, L

    2014-09-01

    Bladder catheter can induce a Catheter-Related Bladder Discomfort (CRBD). Antagonist of muscarinic receptor is the gold standard treatment. Clonazepam is an antimuscarinic, muscle relaxing oral drug. The aim of this study is to look for a correlation between the type of surgical procedure and the existence of CRBD and to evaluate the efficiency of clonazepam. One hundred patients needing bladder catheter were evaluated. Sexe, age, BMI, presence of diabetes, surgical procedure and existence of CRBD were noted. Pain was evaluated with analogic visual scale. Timing of pain, need for specific treatment by clonazepam and its efficiency were noted. Correlation between preoperative data, type of surgical procedure, existence of CRBD and efficiency of treatment were evaluated. There were 79 men and 21 women (age: 65.9 years, BMI: 25.4). Twelve patients presented diabetes. Surgical procedure concerned prostate in 39 cases, bladder in 19 cases (tumor resections), endo-urology in 20 cases, upper urinary tract in 12 cases (nephrectomy…) and lower urinary tract in 10 cases (sphincter, sub-uretral tape). Forty patients presented CRBD, (pain 4.5 using VAS). This pain occurred 0.6 days after surgery. No correlation was found between preoperative data and CRBD. Bladder resection and endo-urological procedures were surgical procedures which procured CRBD. Clonazepam was efficient in 30 (75 %) out of 40 patients with CRBD. However, it was less efficient in case of bladder tumor resection. CRBD is frequent and occurred immediately after surgery. Bladder resection and endo-urology were the main surgical procedures which induced CRBD. Clonazepam is efficient in 75 %. Bladder resection is the surgical procedure which is the most refractory to treatment. 5. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Test and Evaluation of an Image-Matching Navigation System for a UAS Operating in a GPS-Denied Environment

    DTIC Science & Technology

    2017-09-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS TEST AND EVALUATION OF AN IMAGE-MATCHING NAVIGATION SYSTEM FOR A UAS OPERATING IN A GPS-DENIED...INTENTIONALLY LEFT BLANK ii Approved for public release. Distribution is unlimited. TEST AND EVALUATION OF AN IMAGE-MATCHING NAVIGATION SYSTEM FOR A UAS... Evaluation Setup and Procedures 39 4.1 Test Equipment and Data Collection Procedures . . . . . . . . . . . . 39 4.2 Actual Flight Data Collection

  19. Evaluation of an endoscopically assisted gastropexy technique in dogs.

    PubMed

    Dujowich, Mauricio; Reimer, S Brent

    2008-04-01

    To evaluate the use of endoscopy in conjunction with a gastropexy technique in dogs as a potential means to aid prevention of gastric dilatation-volvulus. 12 healthy adult medium- and large-breed dogs. 12 adult research dogs that had no abnormal physical examination findings each underwent an endoscopically assisted gastropexy procedure. On completion of the procedure, the dogs were euthanized and exploratory laparotomies were performed to evaluate the surgical site. Data recorded included anatomic location of the gastropexy, gastropexy length, and duration of procedure as well as any complications. Mean+/-SD gastropexy length was 3.3+/-0.25 cm, and mean duration of surgery was 18+/-7 minutes. In each dog, the stomach was located in its normal anatomic position and all gastropexies were sutured to the abdominal wall at the level of the pyloric antrum. The only complications during the procedure were needle bending and breakage at the time of stay suture placement. On the basis of these findings, it appears that endoscopically assisted gastropexy is a simple, fast, safe, and reliable method of performing a prophylactic gastropexy in dogs when undertaken by a person who is skilled in endoscopy. Such a procedure maximizes the benefits of decreased morbidity and shorter duration of anesthesia associated with minimally invasive surgery. Further clinical studies are warranted to evaluate the long-term efficacy of this procedure in dogs at risk for development of gastric dilatation-volvulus.

  20. Specific test and evaluation plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), andmore » Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  1. Evaluation and treatment of failed shoulder instability procedures.

    PubMed

    Ho, Anthony G; Gowda, Ashok L; Michael Wiater, J

    2016-09-01

    Management of the unstable shoulder after a failed stabilization procedure can be difficult and challenging. Detailed understanding of the native shoulder anatomy, including its static and dynamic restraints, is necessary for determining the patient's primary pathology. In addition, evaluation of the patient's history, physical exam, and imaging is important for identifying the cause for failure after the initial procedure. Common mistakes include under-appreciation of bony defects, failure to recognize capsular laxity, technical errors, and missed associated pathology. Many potential treatment options exist for revision surgery, including open or arthroscopic Bankart repair, bony augmentation procedures, and management of Hill Sachs defects. The aim of this narrative review is to discuss in-depth the common risk factors for post-surgical failure, components for appropriate evaluation, and the different surgical options available for revision stabilization. Level of evidence Level V.

  2. Powertrain Test Procedure Development for EPA GHG Certification of Medium- and Heavy-Duty Engines and Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chambon, Paul H.; Deter, Dean D.

    2016-07-01

    xiii ABSTRACT The goal of this project is to develop and evaluate powertrain test procedures that can accurately simulate real-world operating conditions, and to determine greenhouse gas (GHG) emissions of advanced medium- and heavy-duty engine and vehicle technologies. ORNL used their Vehicle System Integration Laboratory to evaluate test procedures on a stand-alone engine as well as two powertrains. Those components where subjected to various drive cycles and vehicle conditions to evaluate the validity of the results over a broad range of test conditions. Overall, more than 1000 tests were performed. The data are compiled and analyzed in this report.

  3. Evaluation of signal timing and coordination procedures.

    DOT National Transportation Integrated Search

    1985-01-01

    Based on a review of available literature, recommended procedures for timing the various types of signals are provided. Specifically, procedures are included for both pretimed and vehicle-actuated controllers located at isolated intersections and at ...

  4. Practical Guide for the Selection of Audio Visual Media. General Criteria System and Evaluation Procedure for Educational Media Decisions.

    ERIC Educational Resources Information Center

    Klepzig, H. J.; Weiss, M.

    Designed to aid in making concrete decisions on the acquisition and use of media, the criteria system and evaluation procedure described is a multiphase, objective-based decision making process. This report includes guidelines for setting up goal systems and developing criteria for the evaluation of media based on a goal system; an outline of…

  5. Evaluation of Procedures for Backcalculation of Airfield Pavement Moduli

    DTIC Science & Technology

    2015-08-01

    to develop pavement design and structural evaluation criteria, procedures, and software to ensure that its airfield pavements can support mission...aircraft. As tire pressures and aircraft weights have increased steadily during this time, the design and evaluation software– Pavement -Transportation...the remaining life for the pavement in terms of remaining pavement life (passes-to-failure) or allowable gross aircraft loads and also to design

  6. Pre-Then-Post Testing: A Tool To Improve the Accuracy of Management Training Program Evaluation.

    ERIC Educational Resources Information Center

    Mezoff, Bob

    1981-01-01

    Explains a procedure to avoid the detrimental biases of conventional self-reports of training outcomes. The evaluation format provided is a method for using statistical procedures to increase the accuracy of self-reports by overcoming response-shift-bias. (Author/MER)

  7. Guide for the Evaluation and Accreditation of Institutions in Oklahoma Higher Education.

    ERIC Educational Resources Information Center

    Oklahoma State Regents for Higher Education, Oklahoma City.

    Policies and procedures for accreditation, evaluation, and establishment of new institutions are presented. Part 1 outlines the policies and procedures for state accreditation as required by state law. These cover accreditation standards, expenses, consultants, institution's request for accreditation, institutional self-study, statistical…

  8. Development of RAD-Score: A Tool to Assess the Procedural Competence of Diagnostic Radiology Residents.

    PubMed

    Isupov, Inga; McInnes, Matthew D F; Hamstra, Stan J; Doherty, Geoffrey; Gupta, Ashish; Peddle, Susan; Jibri, Zaid; Rakhra, Kawan; Hibbert, Rebecca M

    2017-04-01

    The purpose of this study is to develop a tool to assess the procedural competence of radiology trainees, with sources of evidence gathered from five categories to support the construct validity of tool: content, response process, internal structure, relations to other variables, and consequences. A pilot form for assessing procedural competence among radiology residents, known as the RAD-Score tool, was developed by evaluating published literature and using a modified Delphi procedure involving a group of local content experts. The pilot version of the tool was tested by seven radiology department faculty members who evaluated procedures performed by 25 residents at one institution between October 2014 and June 2015. Residents were evaluated while performing multiple procedures in both clinical and simulation settings. The main outcome measure was the percentage of residents who were considered ready to perform procedures independently, with testing conducted to determine differences between levels of training. A total of 105 forms (for 52 procedures performed in a clinical setting and 53 procedures performed in a simulation setting) were collected for a variety of procedures (eight vascular or interventional, 42 body, 12 musculoskeletal, 23 chest, and 20 breast procedures). A statistically significant difference was noted in the percentage of trainees who were rated as being ready to perform a procedure independently (in postgraduate year [PGY] 2, 12% of residents; in PGY3, 61%; in PGY4, 85%; and in PGY5, 88%; p < 0.05); this difference persisted in the clinical and simulation settings. User feedback and psychometric analysis were used to create a final version of the form. This prospective study describes the successful development of a tool for assessing the procedural competence of radiology trainees with high levels of construct validity in multiple domains. Implementation of the tool in the radiology residency curriculum is planned and can play an instrumental role in the transition to competency-based radiology training.

  9. A method of automatic control procedures cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.

    2015-11-01

    The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.

  10. Evaluation of results of US corn and soybeans exploratory experiment: Classification procedures verification test. [Missouri, Iowa, Indiana, and Illinois

    NASA Technical Reports Server (NTRS)

    Carnes, J. G.; Baird, J. E. (Principal Investigator)

    1980-01-01

    The classification procedure utilized in making crop proportion estimates for corn and soybeans using remotely sensed data was evaluated. The procedure was derived during the transition year of the Large Area Crop Inventory Experiment. Analysis of variance techniques were applied to classifications performed by 3 groups of analysts who processed 25 segments selected from 4 agrophysical units (APU's). Group and APU effects were assessed to determine factors which affected the quality of the classifications. The classification results were studied to determine the effectiveness of the procedure in producing corn and soybeans proportion estimates.

  11. Occupational radiation exposure in vascular interventional radiology: A complete evaluation of different body regions.

    PubMed

    Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Nicolucci, Patrícia; Pina, Diana Rodrigues de

    2016-08-01

    To perform a complete evaluation on radiation doses, received by primary and assistant medical staff, while performing different vascular interventional radiology procedures. We evaluated dose received in different body regions during three categories of vascular procedures: lower limb angiography (Angiography), lower limb percutaneous transluminal angioplasty (Angioplasty) and stent graft placement for abdominal aortic aneurysm treatment (A. A. A. Treatment). We positioned the dosimeters near the eye lens, thyroid, chest, abdomen, hands, and feet of the interventional physicians. Equivalent dose was compared with annual dose limits for workers in order to determine the maximum number of procedures per year that each physician could perform. We assessed 90 procedures. We found the highest equivalent doses in the A. A. A. Treatment, in which 90% of the evaluations indicated at least one region receiving more than 1mSv per procedure. Angioplasty was the only procedural modality that provided statistically different doses for different professionals, which is an important aspect on regards to radiological protection strategies. In comparison with the dose limits, the most critical region in all procedures was the eye lens. Since each body region of the interventionist is exposed to different radiation levels, dose distribution measurements are essential for radiological protection strategies. These results indicate that dosimeters placed in abdomen instead of chest may represent more accurately the whole body doses received by the medical staff. Additional dosimeters and a stationary shield for the eye lens are strongly recommended. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. MnDOT thin whitetopping selection procedures : final report.

    DOT National Transportation Integrated Search

    2017-06-01

    This report provides an integrated selection procedure for evaluating whether an existing hot-mix asphalt (HMA) pavement is an appropriate candidate for a bonded concrete overlay of asphalt (BCOA). The selection procedure includes (1) a desk review, ...

  13. Verification of the ODOT overlay design procedure : final report, June 1996.

    DOT National Transportation Integrated Search

    1996-06-01

    The current ODOT overlay design procedure sometimes indicates additional pavement thickness is needed right after the overlay construction. Evaluation of the current procedure reveals that using spreadabiity to back calculate existing pavement modulu...

  14. [Assessment of the announcement procedure in 29 cancer-accredited hospitals in the Aquitaine region: the EVADA project].

    PubMed

    Rongère-Casteigt, Julie; Pinon, Elodie; Domecq, Sandrine; Hoppe, Stéphanie; Bousser, Véronique; Vimard, Edwige; Saillour-Glenisson, Florence

    2015-01-01

    An announcement procedure is mandatory to obtain accreditation to treat cancer patients. Health care professionals in the Aquitaine region evaluated the organization of this announcement procedure in their institutions and the patients' perception, in order to initiate actions to improve the structure and traceability of this procedure. Self-assessment approach based on a retrospective study plan comprising three concomitant steps: organizational audit, medical records audit and patient experience survey. 29 institutions participated in the study. Heterogeneous organizations were observed, although progress had been made in the deployment of the announcement procedure in terms of personnel training,formal organization and the resources devoted to this procedure, but there remains considerable room for improvement in terms of traceability, coordination between doctors and nursing staff, and referral of patients to supportive care. This evaluation triggered active mobilization of hospital teams concerning the announcement procedure in the Aquitaine region and a better awareness of the patient's perception. The regional dynamic allowed exchanges between institutions, facilitating the implementation of improvement actions.

  15. A Baseline Evaluation Procedure for Federal Standards on the Prevention, Identification and Treatment of Child Abuse and Neglect. Volume I: Development, Field Testing and Recommended Procedure. Volume II: State of Washington Field Test.

    ERIC Educational Resources Information Center

    Seaberg, James R.; And Others

    The National Center on Child Abuse and Neglect funded a project to develop and field-test an evaluation procedure that could be used by interested states or communities to determine the extent of congruity between (1) their provisions for responding to the problems of child abuse and neglect, and (2) provisions prescribed in the Federal Standards…

  16. Evaluating the heat pump alternative for heating enclosed wastewater treatment facilities in cold regions

    NASA Astrophysics Data System (ADS)

    Martel, C. J.; Phetteplace, G. E.

    1982-05-01

    This report presents a five-step procedure for evaluating the technical and economic feasibility of using heat pumps to recover heat from treatment plant effluent. The procedure is meant to be used at the facility planning level by engineers who are unfamiliar with this technology. An example of the use of the procedure and general design information are provided. Also, the report reviews the operational experience with heat pumps at wastewater plants located in Fairbanks, Alaska, Madison, Wisconsin, and Wilton, Maine.

  17. Evaluating Content Alignment in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wise, Steven L.; Kingsbury, G. Gage; Webb, Norman L.

    2015-01-01

    The alignment between a test and the content domain it measures represents key evidence for the validation of test score inferences. Although procedures have been developed for evaluating the content alignment of linear tests, these procedures are not readily applicable to computerized adaptive tests (CATs), which require large item pools and do…

  18. A Parent-Oriented Approach to Rapid Toilet Training

    ERIC Educational Resources Information Center

    Doan, Dai; Toussaint, Karen A.

    2016-01-01

    The current evaluation assessed the effectiveness of a rapid toilet training procedure for three young males with autism. The evaluation extended the research on rapid toilet training procedures by assessing parents' preference to include two common toilet training components, a urine alarm and positive practice. In addition, we assessed child…

  19. Effects of Computer-Based Training on Procedural Modifications to Standard Functional Analyses

    ERIC Educational Resources Information Center

    Schnell, Lauren K.; Sidener, Tina M.; DeBar, Ruth M.; Vladescu, Jason C.; Kahng, SungWoo

    2018-01-01

    Few studies have evaluated methods for training decision-making when functional analysis data are undifferentiated. The current study evaluated computer-based training to teach 20 graduate students to arrange functional analysis conditions, analyze functional analysis data, and implement procedural modifications. Participants were exposed to…

  20. 23 CFR 669.21 - Procedure for evaluating state compliance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 23 Highways 1 2014-04-01 2014-04-01 false Procedure for evaluating state compliance. 669.21 Section 669.21 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND... FHWA. The State may develop a software system to maintain copies or images of this proof-of-payment...

  1. 23 CFR 669.21 - Procedure for evaluating state compliance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 23 Highways 1 2012-04-01 2012-04-01 false Procedure for evaluating state compliance. 669.21 Section 669.21 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND... FHWA. The State may develop a software system to maintain copies or images of this proof-of-payment...

  2. 23 CFR 669.21 - Procedure for evaluating state compliance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 23 Highways 1 2011-04-01 2011-04-01 false Procedure for evaluating state compliance. 669.21 Section 669.21 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND... FHWA. The State may develop a software system to maintain copies or images of this proof-of-payment...

  3. 23 CFR 669.21 - Procedure for evaluating state compliance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 23 Highways 1 2013-04-01 2013-04-01 false Procedure for evaluating state compliance. 669.21 Section 669.21 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND... FHWA. The State may develop a software system to maintain copies or images of this proof-of-payment...

  4. 7 CFR 1753.8 - Contract construction procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... of all bids including “Buy American” evaluations, if any, and all other evaluations required by law... Contract construction procedures. (a) Sealed, competitive bidding—(1) Bid opening date. The borrower is responsible for scheduling the bid opening date. If RUS review of P&S is required by § 1753.7, the borrower...

  5. Accreditation Standards: Policies, Procedures, and Criteria. Revised Edition.

    ERIC Educational Resources Information Center

    Association of Independent Colleges and Schools, Washington, DC.

    Statements of policies and procedures and evaluation criteria used by the Accrediting Commission of the Association of Independent Colleges and Schools are presented. The organization and function of the Accrediting Commission, the bases of eligibility for evaluation and accreditation of all types of institutions, and the general classification of…

  6. 29 CFR 1956.24 - Procedures for withdrawal of approval.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Procedures for withdrawal of approval. 1956.24 Section 1956..., Change, Evaluation and Withdrawal of Approval Procedures § 1956.24 Procedures for withdrawal of approval... withdrawal of approval of plans approved under this part 1956, except that (because these plans, as do public...

  7. A Comparison of Exposure Control Procedures in CATs Using the 3PL Model

    ERIC Educational Resources Information Center

    Leroux, Audrey J.; Lopez, Myriam; Hembry, Ian; Dodd, Barbara G.

    2013-01-01

    This study compares the progressive-restricted standard error (PR-SE) exposure control procedure to three commonly used procedures in computerized adaptive testing, the randomesque, Sympson-Hetter (SH), and no exposure control methods. The performance of these four procedures is evaluated using the three-parameter logistic model under the…

  8. Predictive procedure for compensatory hyperhidrosis before sympathectomy: preliminary findings.

    PubMed

    Jeong, Jin Yong; Park, Hyung Joo; Park, Jae Kil; Jo, Keon Hyeon; Wang, Young Pil; Lee, Jongho; Shin, Jae Seong

    2014-08-01

    Compensatory hyperhidrosis is one of the most common and serious adverse effects following sympathectomy. We performed a local anesthetic procedure that predicts the occurrence and severity of compensatory hyperhidrosis, and evaluated the feasibility, safety, and efficacy of the procedure. From July 2009 to July 2010, 20 patients with severe primary palmar hyperhidrosis underwent predictive procedures. A sympathetic nerve block was obtained via thoracoscopic approach under local anesthesia. The patients were evaluated for compensatory hyperhidrosis 1 week after the procedure before deciding whether to proceed with sympathectomy. Of the 20 patients, 17 patients proceeded with sympathectomy and 3 refused the final procedure. Following sympathectomy, the occurrence and severity of compensatory hyperhidrosis in the remaining 17 patients were statistically analyzed with two tailed paired t test, and there is no significant difference between the predictive and final procedures (t = 1.69, df = 16, p > 0.1). Predictive procedure using local anesthesia to detect compensatory hyperhidrosis before sympathectomy may be useful for helping patients to decide whether to undergo the operation. Georg Thieme Verlag KG Stuttgart · New York.

  9. Evaluation of a training manual for the acquisition of behavioral assessment interviewing skills.

    PubMed Central

    Miltenberger, R G; Fuqua, R W

    1985-01-01

    Two procedures were used to teach behavioral assessment interviewing skills: a training manual and one-to-one instruction that included modeling, rehearsal, and feedback. Two graduate students and two advanced undergraduates were trained with each procedure. Interviewing skills were recorded in simulated assessment interviews conducted by each student across baseline and treatment conditions. Each training procedure was evaluated in a multiple baseline across students design. The results showed that both procedures were effective for training behavioral interviewing skills, with all students reaching a level of 90%-100% correct responding. Finally, a group of experts in behavior analysis rated each interviewing skill as relevant to the conduct of an assessment interview and a group of behavioral clinicians socially validated the outcomes of the two procedures. PMID:4086413

  10. Save the last dance for me: unwanted serial position effects in jury evaluations.

    PubMed

    Bruine de Bruin, Wändi

    2005-03-01

    Whenever competing options are considered in sequence, their evaluations may be affected by order of appearance. Such serial position effects would threaten the fairness of competitions using jury evaluations. Randomization cannot reduce potential order effects, but it does give candidates an equal chance of being assigned to preferred serial positions. Whether, or what, serial position effects emerge may depend on the cognitive demands of the judgment task. In end-of-sequence procedures, final scores are not given until all candidates have performed, possibly burdening judges' memory. If judges' evaluations are based on how well they remember performances, serial position effects may resemble those found with free recall. Candidates may also be evaluated step-by-step, immediately after each performance. This procedure should not burden memory, though it may produce different serial position effects. Yet, this paper reports similar serial position effects with end-of-sequence and step-by-step procedures used for the Eurovision Song Contest: Ratings increased with serial position. The linear order effect was replicated in the step-by-step judgments of World and European Figure Skating Contests. It is proposed that, independent of the evaluation procedure, judges' initial impressions of sequentially appearing candidates may be formed step-by-step, yielding serial position effects.

  11. Gastroscopy: a primary diagnostic procedure.

    PubMed

    Coleman, W H

    1988-03-01

    EGD, using 1986 models of either the fiberoptic gastroscope or the videoscope, is a safe and accurate procedure that can be performed by any physician trained in the technique of endoscope passage. It may be performed at large medical centers or small rural hospitals, outpatient clinics, or even private offices. Patients themselves have indicated preference for endoscopic evaluation over the double-contrast barium meal after they have experienced both procedures. The short time of procedure, its accuracy, safety, and its relative lack of discomfort to the patient lend it readily to being an initial component in the primary evaluation of symptoms of abdominal distress, gastrointestinal bleeding, dysphagia, esophageal reflux, persistent vomiting, and odynophagia. It is essential in the evaluation of complications of esophageal reflux and the evaluation of abnormal radiological findings in the upper gastrointestinal tract. It should never be overlooked in evaluating the patient with iron deficiency anemia of unknown etiology. Economic pressures have already moved EGD from the surgery wards to endoscopy labs and to the outpatient setting. These same forces will project more physicians into the role of the diagnostic endoscopist and the patient will benefit by decreased medical costs, quicker diagnosis and treatment, and enhanced continuity of care.

  12. Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials: An Academic Research Consortium Initiative.

    PubMed

    Lansky, Alexandra J; Messé, Steven R; Brickman, Adam M; Dwyer, Michael; Bart van der Worp, H; Lazar, Ronald M; Pietras, Cody G; Abrams, Kevin J; McFadden, Eugene; Petersen, Nils H; Browndyke, Jeffrey; Prendergast, Bernard; Ng, Vivian G; Cutlip, Donald E; Kapadia, Samir; Krucoff, Mitchell W; Linke, Axel; Scala Moy, Claudia; Schofer, Joachim; van Es, Gerrit-Anne; Virmani, Renu; Popma, Jeffrey; Parides, Michael K; Kodali, Susheel; Bilello, Michel; Zivadinov, Robert; Akar, Joseph; Furie, Karen L; Gress, Daryl; Voros, Szilard; Moses, Jeffrey; Greer, David; Forrest, John K; Holmes, David; Kappetein, Arie P; Mack, Michael; Baumbach, Andreas

    2018-05-14

    Surgical and catheter-based cardiovascular procedures and adjunctive pharmacology have an inherent risk of neurological complications. The current diversity of neurological endpoint definitions and ascertainment methods in clinical trials has led to uncertainties in the neurological risk attributable to cardiovascular procedures and inconsistent evaluation of therapies intended to prevent or mitigate neurological injury. Benefit-risk assessment of such procedures should be on the basis of an evaluation of well-defined neurological outcomes that are ascertained with consistent methods and capture the full spectrum of neurovascular injury and its clinical effect. The Neurologic Academic Research Consortium is an international collaboration intended to establish consensus on the definition, classification, and assessment of neurological endpoints applicable to clinical trials of a broad range of cardiovascular interventions. Systematic application of the proposed definitions and assessments will improve our ability to evaluate the risks of cardiovascular procedures and the safety and effectiveness of preventive therapies.

  13. Project W-314 specific test and evaluation plan for AZ tank farm upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-08-12

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests andmore » inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  14. Review on Rapid Seismic Vulnerability Assessment for Bulk of Buildings

    NASA Astrophysics Data System (ADS)

    Nanda, R. P.; Majhi, D. R.

    2013-09-01

    This paper provides a brief overview of rapid visual screening (RVS) procedures available in different countries with a comparison among all the methods. Seismic evaluation guidelines from, USA, Canada, Japan, New Zealand, India, Europe, Italy, UNDP, with other methods are reviewed from the perspective of their applicability to developing countries. The review shows clearly that some of the RVS procedures are unsuited for potential use in developing countries. It is expected that this comparative assessment of various evaluation schemes will help to identify the most essential components of such a procedure for use in India and other developing countries, which is not only robust, reliable but also easy to use with available resources. It appears that Federal Emergency Management Agency (FEMA) 154 and New Zealand Draft Code approaches can be suitably combined to develop a transparent, reasonably rigorous and generalized procedure for seismic evaluation of buildings in developing countries.

  15. Improved Equivalent Linearization Implementations Using Nonlinear Stiffness Evaluation

    NASA Technical Reports Server (NTRS)

    Rizzi, Stephen A.; Muravyov, Alexander A.

    2001-01-01

    This report documents two new implementations of equivalent linearization for solving geometrically nonlinear random vibration problems of complicated structures. The implementations are given the acronym ELSTEP, for "Equivalent Linearization using a STiffness Evaluation Procedure." Both implementations of ELSTEP are fundamentally the same in that they use a novel nonlinear stiffness evaluation procedure to numerically compute otherwise inaccessible nonlinear stiffness terms from commercial finite element programs. The commercial finite element program MSC/NASTRAN (NASTRAN) was chosen as the core of ELSTEP. The FORTRAN implementation calculates the nonlinear stiffness terms and performs the equivalent linearization analysis outside of NASTRAN. The Direct Matrix Abstraction Program (DMAP) implementation performs these operations within NASTRAN. Both provide nearly identical results. Within each implementation, two error minimization approaches for the equivalent linearization procedure are available - force and strain energy error minimization. Sample results for a simply supported rectangular plate are included to illustrate the analysis procedure.

  16. Computerization of a preanesthetic evaluation and user satisfaction evaluation.

    PubMed

    Arias, Antonio; Benítez, Sonia; Canosa, Daniela; Borbolla, Damián; Staccia, Gustavo; Plazzotta, Fernando; Casais, Marcela; Michelangelo, Hernán; Luna, Daniel; Bernaldo de Quirós, Fernán Gonzalez

    2010-01-01

    Preanesthetic evaluation purpose is to reduce morbidity and mortality through the review of the patient's medical history, clinical examination, and targeted clinical studies, providing referrals for medical consultations when appropriated. Changes in patient care, standards of health information management and patterns of perioperative care, have resulted in a re-conceptualization of this process where the documentation of patient medical information, the efforts in training and maintaining the integrity of the medical-legal evaluation are areas of concern. The aim of this paper is to describe the design, development, training, and implementation of a computerized preanesthetic evaluation form associated to the evaluation of the user satisfaction with the system. Since the system went live in September 2008 there were 15121 closed structured forms, 60% for ambulatory procedures and 40 % for procedures that required hospital admission. 82% of total closed structured forms had recorded a risk of the procedures of 1-2, according to the American Society of Anesthesiologists classification. The survey indicates a positive general satisfaction of the users with the system.

  17. Procedural Metacognition and False Belief Understanding in 3- to 5-Year-Old Children

    PubMed Central

    Bernard, Stéphane; Proust, Joëlle; Clément, Fabrice

    2015-01-01

    Some studies, so far limited in number, suggest the existence of procedural metacognition in young children, that is, the practical capacity to monitor and control one’s own cognitive activity in a given task. The link between procedural metacognition and false belief understanding is currently under theoretical discussion. If data with primates seem to indicate that procedural metacognition and false belief understanding are not related, no study in developmental psychology has investigated this relation in young children. The present paper aims, first, to supplement the findings concerning young children’s abilities to monitor and control their uncertainty (procedural metacognition) and, second, to explore the relation between procedural metacognition and false belief understanding. To examine this, 82 3- to 5-year-old children were presented with an opt-out task and with 3 false belief tasks. Results show that children can rely on procedural metacognition to evaluate their perceptual access to information, and that success in false belief tasks does not seem related to success in the task we used to evaluate procedural metacognition. These results are coherent with a procedural view of metacognition, and are discussed in the light of recent data from primatology and developmental psychology. PMID:26517260

  18. Procedural Metacognition and False Belief Understanding in 3- to 5-Year-Old Children.

    PubMed

    Bernard, Stéphane; Proust, Joëlle; Clément, Fabrice

    2015-01-01

    Some studies, so far limited in number, suggest the existence of procedural metacognition in young children, that is, the practical capacity to monitor and control one's own cognitive activity in a given task. The link between procedural metacognition and false belief understanding is currently under theoretical discussion. If data with primates seem to indicate that procedural metacognition and false belief understanding are not related, no study in developmental psychology has investigated this relation in young children. The present paper aims, first, to supplement the findings concerning young children's abilities to monitor and control their uncertainty (procedural metacognition) and, second, to explore the relation between procedural metacognition and false belief understanding. To examine this, 82 3- to 5-year-old children were presented with an opt-out task and with 3 false belief tasks. Results show that children can rely on procedural metacognition to evaluate their perceptual access to information, and that success in false belief tasks does not seem related to success in the task we used to evaluate procedural metacognition. These results are coherent with a procedural view of metacognition, and are discussed in the light of recent data from primatology and developmental psychology.

  19. New procedures to evaluate visually lossless compression for display systems

    NASA Astrophysics Data System (ADS)

    Stolitzka, Dale F.; Schelkens, Peter; Bruylants, Tim

    2017-09-01

    Visually lossless image coding in isochronous display streaming or plesiochronous networks reduces link complexity and power consumption and increases available link bandwidth. A new set of codecs developed within the last four years promise a new level of coding quality, but require new techniques that are sufficiently sensitive to the small artifacts or color variations induced by this new breed of codecs. This paper begins with a summary of the new ISO/IEC 29170-2, a procedure for evaluation of lossless coding and reports the new work by JPEG to extend the procedure in two important ways, for HDR content and for evaluating the differences between still images, panning images and image sequences. ISO/IEC 29170-2 relies on processing test images through a well-defined process chain for subjective, forced-choice psychophysical experiments. The procedure sets an acceptable quality level equal to one just noticeable difference. Traditional image and video coding evaluation techniques, such as, those used for television evaluation have not proven sufficiently sensitive to the small artifacts that may be induced by this breed of codecs. In 2015, JPEG received new requirements to expand evaluation of visually lossless coding for high dynamic range images, slowly moving images, i.e., panning, and image sequences. These requirements are the basis for new amendments of the ISO/IEC 29170-2 procedures described in this paper. These amendments promise to be highly useful for the new content in television and cinema mezzanine networks. The amendments passed the final ballot in April 2017 and are on track to be published in 2018.

  20. Controlled and implicit processes in evaluative conditioning on implicit and explicit attitudes toward alcohol and intentions to drink.

    PubMed

    Zerhouni, Oulmann; Bègue, Laurent; Comiran, Francisco; Wiers, Reinout W

    2018-01-01

    Since implicit attitudes (i.e. evaluations occurring outside of complete awareness) are highly predictive of alcohol consumption, we tested an evaluative learning procedure based on repeated pairing to a critical stimulus (i.e. alcohol, the CS) with a valenced stimulus (the US) in order to modify implicit attitudes (i.e. evaluative conditioning; EC). We hypothesized that manipulating the learning context to bolster implicit affect misattribution should strengthen EC effects on implicit attitudes toward alcohol, while encouraging deliberate processing of CS-US pairs, should strengthen EC effects on explicit attitudes. In our study (n=114 students) we manipulated whether CS-US pairs were presented simultaneously or sequentially. Recollective memory was estimated with a Process Dissociation Procedure. Both implicit and explicit attitudes were assessed immediately after the procedure. Behavioral intentions were measured directly after and one week after the EC-procedure. We found that EC with sequential presentation had a stronger impact on implicit and explicit measures and on purchase intentions immediately after the procedure and one week after. The present findings provide new evidence that (i) EC is an effective way to change implicit attitudes toward alcohol and (ii) evidence that EC may be better described by propositional rather than dual process accounts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    PubMed

    Sparding, Nadja; Slotved, Hans-Christian; Nicolaisen, Gert M; Giese, Steen B; Elmlund, Jón; Steenhard, Nina R

    2014-01-01

    After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin) with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments) for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  2. Relative value of dental procedures.

    PubMed

    Tuominen, R; Tuominen, M

    1994-10-01

    This study was conducted to develop a relative value method for dental procedures, and to evaluate the differences in values assigned by private and public sector dentists. Samples of 90 general practitioners and 120 clinical specialists were systematically drawn to represent all actively working Finnish dentists. The dentists were asked to assess the required time and know-how for performing various procedures compared to performing a two-surface amalgam filling (AF2). At the end, the dentists were asked to divide the value of 200 between time and know-how for the reference procedure (AF2). These figures were then utilized to calculate the average relative value for each procedure. Private practitioners' weighted relative values were 55.3% higher than the prices, and among public sector dentists they were 27.9% higher. Overall, know-how constituted more of the total value of the procedures than did time. Private practitioners' time assessments correlated well (r = 0.72-0.95) with the recommended prices. However, significant differences were often observed both in time and know-how assessments of individual procedures. Both time and know-how seem to be important factors when determining values for dental services. For evaluation of the value of output in the private sector, the use of prices is justified. However, when the productivity of non-profit dental offices is evaluated, a value system which is not based on market prices is needed.

  3. Simple Psychological Interventions for Reducing Pain From Common Needle Procedures in Adults

    PubMed Central

    Boerner, Katelynn E.; Birnie, Kathryn A.; Taddio, Anna; McMurtry, C. Meghan; Noel, Melanie; Shah, Vibhuti; Pillai Riddell, Rebecca

    2015-01-01

    Background: This systematic review evaluated the effectiveness of simple psychological interventions for managing pain and fear in adults undergoing vaccination or related common needle procedures (ie, venipuncture/venous cannulation). Design/Methods: Databases were searched to identify relevant randomized and quasi-randomized controlled trials. Self-reported pain and fear were prioritized as critically important outcomes. Data were combined using standardized mean difference (SMD) or relative risk (RR) with 95% confidence intervals (CI). Results: No studies involving vaccination met inclusion criteria; evidence was drawn from 8 studies of other common needle procedures (eg, venous cannulation, venipuncture) in adults. Two trials evaluating the impact of neutral signaling of the impending procedure (eg, “ready?”) as compared with signaling of impending pain (eg, “sharp scratch”) demonstrated lower pain when signaled about the procedure (n=199): SMD=−0.97 (95% CI, −1.26, −0.68), after removal of 1 trial where self-reported pain was significantly lower than the other 2 included trials. Two trials evaluated music distraction (n=156) and demonstrated no difference in pain: SMD=0.10 (95% CI, −0.48, 0.27), or fear: SMD=−0.25 (95% CI, −0.61, 0.10). Two trials evaluated visual distraction and demonstrated no difference in pain (n=177): SMD=−0.57 (95% CI, −1.82, 0.68), or fear (n=81): SMD=−0.05 (95% CI, −0.50, 0.40). Two trials evaluating breathing interventions found less pain in intervention groups (n=138): SMD=−0.82 (95% CI, −1.21, −0.43). The quality of evidence across all trials was very low. Conclusions: There are no published studies of simple psychological interventions for vaccination pain in adults. There is some evidence of a benefit from other needle procedures for breathing strategies and neutral signaling of the start of the procedure. There is no evidence for use of music or visual distraction. PMID:26352921

  4. Comprehensive evaluation of lung allograft function in infants after lung and heart-lung transplantation.

    PubMed

    Hayes, Don; Naguib, Aymen; Kirkby, Stephen; Galantowicz, Mark; McConnell, Patrick I; Baker, Peter B; Kopp, Benjamin T; Lloyd, Eric A; Astor, Todd L

    2014-05-01

    Limited data exist on methods to evaluate allograft function in infant recipients of lung and heart-lung transplants. At our institution, we developed a procedural protocol in coordination with pediatric anesthesia where infants were sedated to perform infant pulmonary function testing, computed tomography imaging of the chest, and flexible fiberoptic bronchoscopy with transbronchial biopsies. A retrospective review was performed of children aged younger than 1 year who underwent lung or heart-lung transplantation at our institution to assess the effect of this procedural protocol in the evaluation of infant lung allografts. Since 2005, 5 infants have undergone thoracic transplantation (3 heart-lung, 2 lung). At time of transplant, the mean ± standard deviation age was 7.2 ± 2.8 months (range, 3-11 months). Of 24 procedural sessions performed to evaluate lung allografts, 83% (20 of 24) were considered surveillance where the patients were completely asymptomatic. Of the surveillance procedures, 80% were performed as an outpatient, whereas 20% were done as inpatients during the lung or heart-lung transplant post-operative period before discharge home. Sedation was performed with propofol alone (23 of 24) or in addition to ketamine (1 of 24) infusion; mean sedation time was 141 ± 39 minutes (range, 70-214) minutes. Of the 16 outpatient procedures, patients were discharged after 14 (88%) on the same day, and after 2 (12%) were admitted for observation, with 1 being due to transportation issues and the other due to fever during the observation period. A comprehensive procedural protocol to evaluate allograft function in infant lung and heart-lung transplant recipients was performed safely as an outpatient. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  5. Procedures for mastitis diagnosis and control.

    PubMed

    Sears, P M; González, R N; Wilson, D J; Han, H R

    1993-11-01

    Procedures for mastitis diagnosis and control include culturing individual cow and bulk tank milk samples, antibiotic susceptibility testing, and evaluation of somatic cell count reports and clinical mastitis treatment records. Integrated use of such procedures is necessary for effective mastitis diagnosis and control.

  6. Relationship of procedural numbers with meaningful procedural autonomy in general surgery residents.

    PubMed

    Stride, Herbert P; George, Brian C; Williams, Reed G; Bohnen, Jordan D; Eaton, Megan J; Schuller, Mary C; Zhao, Lihui; Yang, Amy; Meyerson, Shari L; Scully, Rebecca; Dunnington, Gary L; Torbeck, Laura; Mullen, John T; Mandell, Samuel P; Choti, Michael; Foley, Eugene; Are, Chandrakanth; Auyang, Edward; Chipman, Jeffrey; Choi, Jennifer; Meier, Andreas; Smink, Douglas; Terhune, Kyla P; Wise, Paul; DaRosa, Debra; Soper, Nathaniel; Zwischenberger, Jay B; Lillemoe, Keith; Fryer, Jonathan P

    2018-03-01

    Concerns exist regarding the competency of general surgery graduates with performing core general surgery procedures. Current competence assessment incorporates minimal procedural numbers requirements. Based on the Zwisch scale we evaluated the level of autonomy achieved by categorical PGY1-5 general surgery residents at 14 U.S. general surgery resident training programs between September 1, 2015 and December 31, 2016. With 5 of the most commonly performed core general surgery procedures, we correlated the level of autonomy achieved by each resident with the number of procedures they had performed before the evaluation period, with the intent of identifying specific target numbers that would correlate with the achievement of meaningful autonomy for each procedure with most residents. Whereas a definitive target number was identified for laparoscopic appendectomy (i.e. 25), for the other 4 procedures studied (i.e. laparoscopic cholecystectomy, 52; open inguinal hernia repair, 42; ventral hernia repair, 35; and partial colectomy, 60), target numbers identified were less definitive and/or were higher than many residents will experience during their surgical residency training. We conclude that procedural target numbers are generally not effective in predicting procedural competence and should not be used as the basis for determining residents' readiness for independent practice. Copyright © 2017. Published by Elsevier Inc.

  7. EVALUATION OF ENVIRONMENTAL HAZARD ASSESSMENT PROCEDURES FOR NEAR-COASTAL AREAS OF THE GULF OF MEXICO

    EPA Science Inventory

    Lewis, Michael A. In press. Evaluation of Environmental Hazard Assessment Procedures for Near-Coastal Areas of the Gulf of Mexico (Abstract). To be presented at the Annual Meeting of the the Australasian Society of Ecotoxicology, July 2004, Gold Coast, Australia. 1 p. (ERL,GB R98...

  8. Teacher Evaluation: Practices and Procedures. ERS Report.

    ERIC Educational Resources Information Center

    Educational Research Service, Arlington, VA.

    This report presents findings of the 1988 Educational Research Service survey of teacher evaluation practices and procedures in U.S. schools. The survey instrument was mailed to a random sample of 1,730 superintendents of school districts of varying size. The response rate was 52.5 percent. The first section discusses the purposes of teacher…

  9. Automated Essay Scoring: Psychometric Guidelines and Practices

    ERIC Educational Resources Information Center

    Ramineni, Chaitanya; Williamson, David M.

    2013-01-01

    In this paper, we provide an overview of psychometric procedures and guidelines Educational Testing Service (ETS) uses to evaluate automated essay scoring for operational use. We briefly describe the e-rater system, the procedures and criteria used to evaluate e-rater, implications for a range of potential uses of e-rater, and directions for…

  10. Detailed Test Plan Redundant Sensor Strapdown IMU Evaluation Program

    NASA Technical Reports Server (NTRS)

    Hartwell, T.; Miyatake, Y.; Wedekind, D. E.

    1971-01-01

    The test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The subjects discussed are: (1) test philosophy and limitations, (2) test sequence, (3) equipment specifications, (4) general operating procedures, (5) calibration procedures, (6) alignment test phase, and (7) navigation test phase. The data and analysis requirements are analyzed.

  11. Efficiency Analysis: Enhancing the Statistical and Evaluative Power of the Regression-Discontinuity Design.

    ERIC Educational Resources Information Center

    Madhere, Serge

    An analytic procedure, efficiency analysis, is proposed for improving the utility of quantitative program evaluation for decision making. The three features of the procedure are explained: (1) for statistical control, it adopts and extends the regression-discontinuity design; (2) for statistical inferences, it de-emphasizes hypothesis testing in…

  12. 23 CFR 669.21 - Procedure for evaluating state compliance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... automated file as evidence that proof of payment has been received before vehicles subject to the Federal... TRAFFIC OPERATIONS ENFORCEMENT OF HEAVY VEHICLE USE TAX § 669.21 Procedure for evaluating state compliance.... In lieu of retention of Schedule 1, states may make an appropriate entry in an automated file or on...

  13. Observational and Incidental Learning by Children with Autism during Small Group Instruction

    ERIC Educational Resources Information Center

    Ledford, Jennifer R.; Gast, David L.; Luscre, Deanna; Ayres, Kevin M.

    2008-01-01

    This study evaluated the acquisition of incidental and observational information presented to 6 children with autism in a small group instructional arrangement using a constant time delay (CTD) procedure. A multiple probe design across behaviors, replicated across 6 participants, was used to evaluate the effectiveness of the CTD procedure and to…

  14. Procedures vs. Incentives: The University Promotion System in Italy

    ERIC Educational Resources Information Center

    Rettore, Enrico; Rocco, Lorenzo; Dal Maso, Carlo

    2018-01-01

    We evaluate two reforms that modified the procedures of recruitment and promotion in Italian academia to balance the preeminent role of the recruiting school and to counter nepotism. We theoretically derive the decision rule of the evaluation committees and test it against data including information from all selections to associate and full…

  15. Stratified and Maximum Information Item Selection Procedures in Computer Adaptive Testing

    ERIC Educational Resources Information Center

    Deng, Hui; Ansley, Timothy; Chang, Hua-Hua

    2010-01-01

    In this study we evaluated and compared three item selection procedures: the maximum Fisher information procedure (F), the a-stratified multistage computer adaptive testing (CAT) (STR), and a refined stratification procedure that allows more items to be selected from the high a strata and fewer items from the low a strata (USTR), along with…

  16. Practices and Procedures in the Administration of ITV Distance Learning Programs at Selected Institutions in Higher Education.

    ERIC Educational Resources Information Center

    Koontz, F. R.

    The purpose of this study was to obtain current data on practices and procedures in the administration of distance learning programs in the areas of: (1) needs assessment; (2) student demographics; (3) telecourse acquisition procedures and sources; (4) criteria used to evaluate credit telecourses; (5) institutional approval procedures; (6)…

  17. An Evaluation of in Vivo Desensitization and Video Modeling to Increase Compliance with Dental Procedures in Persons with Mental Retardation

    ERIC Educational Resources Information Center

    Conyers, Carole; Miltenberger, Raymond G.; Peterson, Blake; Gubin, Amber; Jurgens, Mandy; Selders, Andrew; Dickinson, Jessica; Barenz, Rebecca

    2004-01-01

    Fear of dental procedures deters many individuals with mental retardation from accepting dental treatment. This study was conducted to assess the effectiveness of two procedures, in vivo desensitization and video modeling, for increasing compliance with dental procedures in participants with severe or profound mental retardation. Desensitization…

  18. Cue Reactivity in Young Marijuana Smokers

    PubMed Central

    Gray, Kevin M.; LaRowe, Steven D.; Upadhyaya, Himanshu P.

    2008-01-01

    Objective To develop and evaluate the feasibility of a cue reactivity paradigm for young marijuana smokers. Method A laboratory procedure was developed involving neutral- and marijuana-related imagery, video, and in vivo cues. Fifteen adolescents and young adults with cannabis use disorders completed the procedure. Continuous Skin Conductance (SC) and Heart Rate (HR) were measured throughout the procedure. Participants completed questionnaires regarding marijuana craving before, during and after cue presentations. Results Higher levels of craving and SC were observed during marijuana cue presentations. Conclusions The procedure appears to elicit cue reactivity among adolescents and young adults with cannabis use disorders and should be further evaluated and refined with a larger sample. Implications for future studies are discussed. PMID:19071985

  19. Summary of Federal Aviation Administration Responses to National Transportation Safety Board Safety Recommendations.

    DTIC Science & Technology

    1982-01-01

    A-81-154. A-81-155. Adopt procedures and directives to use the student evaluations prepared by academic personnel at the FAA controller training...density ATC facilities. This determination, which is based on academic evaluations and the performance of the trainee in the radar training facility...81-154) Adopt procedures and directives to use the student evaluations prepared by academic personnel at the FAA controller training center as a

  20. Receipt and Inspection of Chemical - Biological (CB) Materiel

    DTIC Science & Technology

    2017-08-31

    Policy and Standardization Division (CSTE-TM) U.S. Army Test and Evaluation Command 2202 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001...in this TOP is intended for use in the receipt inspection of CB materiel and systems tested by the U.S. Army Test and Evaluation Command (ATEC). The...This page is intentionally blank.) U.S. ARMY TEST AND EVALUATION COMMAND TEST OPERATIONS PROCEDURE *Test Operations Procedure 08-2-500A 31

  1. Medical evaluations on the KC-135 1991 flight report summary

    NASA Technical Reports Server (NTRS)

    Lloyd, Charles W.

    1993-01-01

    The medical investigations completed on the KC-135 during FY 1991 in support of the development of the Health Maintenance Facility and Medical Operations are presented. The experiments consisted of medical and engineering evaluations of medical hardware and procedures and were conducted by medical and engineering personnel. The hardware evaluated included prototypes of a crew medical restraint system and advanced life support pack, a shuttle orbiter medical system, an airway medical accessory kit, a supplementary extended duration orbiter medical kit, and a surgical overhead canopy. The evaluations will be used to design flight hardware and identify hardware-specific training requirements. The following procedures were evaluated: transport of an ill or injured crewmember at man-tended capability, surgical technique in microgravity, transfer of liquids in microgravity, advanced cardiac life support using man-tended capability Health Maintenance Facility hardware, medical transport using a model of the assured crew return vehicle, and evaluation of delivery mechanisms for aerosolized medications in microgravity. The results of these evaluation flights allow for a better understanding of the types of procedures that can be performed in a microgravity environment.

  2. Operational flight evaluation of the two-segment approach for use in airline service

    NASA Technical Reports Server (NTRS)

    Schwind, G. K.; Morrison, J. A.; Nylen, W. E.; Anderson, E. B.

    1975-01-01

    United Airlines has developed and evaluated a two-segment noise abatement approach procedure for use on Boeing 727 aircraft in air carrier service. In a flight simulator, the two-segment approach was studied in detail and a profile and procedures were developed. Equipment adaptable to contemporary avionics and navigation systems was designed and manufactured by Collins Radio Company and was installed and evaluated in B-727-200 aircraft. The equipment, profile, and procedures were evaluated out of revenue service by pilots representing government agencies, airlines, airframe manufacturers, and professional pilot associations. A system was then placed into scheduled airline service for six months during which 555 two-segment approaches were flown at three airports by 55 airline pilots. The system was determined to be safe, easy to fly, and compatible with the airline operational environment.

  3. The AME2016 atomic mass evaluation (I). Evaluation of input data; and adjustment procedures

    NASA Astrophysics Data System (ADS)

    Huang, W. J.; Audi, G.; Wang, Meng; Kondev, F. G.; Naimi, S.; Xu, Xing

    2017-03-01

    This paper is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, AME2016. It includes complete information on the experimental input data (also including unused and rejected ones), as well as details on the evaluation procedures used to derive the tables of recommended values given in the second part. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometric results. These input values were entered in the least-squares adjustment for determining the best values for the atomic masses and their uncertainties. Details of the calculation and particularities of the AME are then described. All accepted and rejected data, including outweighted ones, are presented in a tabular format and compared with the adjusted values obtained using the least-squares fit analysis. Differences with the previous AME2012 evaluation are discussed and specific information is presented for several cases that may be of interest to AME users. The second AME2016 article gives a table with the recommended values of atomic masses, as well as tables and graphs of derived quantities, along with the list of references used in both the AME2016 and the NUBASE2016 evaluations (the first paper in this issue). AMDC: http://amdc.impcas.ac.cn/ Contents The AME2016 atomic mass evaluation (I). Evaluation of input data; and adjustment proceduresAcrobat PDF (1.2 MB) Table I. Input data compared with adjusted valuesAcrobat PDF (1.3 MB)

  4. Crew procedures development techniques

    NASA Technical Reports Server (NTRS)

    Arbet, J. D.; Benbow, R. L.; Hawk, M. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.

    1975-01-01

    The study developed requirements, designed, developed, checked out and demonstrated the Procedures Generation Program (PGP). The PGP is a digital computer program which provides a computerized means of developing flight crew procedures based on crew action in the shuttle procedures simulator. In addition, it provides a real time display of procedures, difference procedures, performance data and performance evaluation data. Reconstruction of displays is possible post-run. Data may be copied, stored on magnetic tape and transferred to the document processor for editing and documentation distribution.

  5. Ordered weighted averaging with fuzzy quantifiers: GIS-based multicriteria evaluation for land-use suitability analysis

    NASA Astrophysics Data System (ADS)

    Malczewski, Jacek

    2006-12-01

    The objective of this paper is to incorporate the concept of fuzzy (linguistic) quantifiers into the GIS-based land suitability analysis via ordered weighted averaging (OWA). OWA is a multicriteria evaluation procedure (or combination operator). The nature of the OWA procedure depends on some parameters, which can be specified by means of fuzzy (linguistic) quantifiers. By changing the parameters, OWA can generate a wide range of decision strategies or scenarios. The quantifier-guided OWA procedure is illustrated using land-use suitability analysis in a region of Mexico.

  6. A comparison of vowel normalization procedures for language variation research

    NASA Astrophysics Data System (ADS)

    Adank, Patti; Smits, Roel; van Hout, Roeland

    2004-11-01

    An evaluation of vowel normalization procedures for the purpose of studying language variation is presented. The procedures were compared on how effectively they (a) preserve phonemic information, (b) preserve information about the talker's regional background (or sociolinguistic information), and (c) minimize anatomical/physiological variation in acoustic representations of vowels. Recordings were made for 80 female talkers and 80 male talkers of Dutch. These talkers were stratified according to their gender and regional background. The normalization procedures were applied to measurements of the fundamental frequency and the first three formant frequencies for a large set of vowel tokens. The normalization procedures were evaluated through statistical pattern analysis. The results show that normalization procedures that use information across multiple vowels (``vowel-extrinsic'' information) to normalize a single vowel token performed better than those that include only information contained in the vowel token itself (``vowel-intrinsic'' information). Furthermore, the results show that normalization procedures that operate on individual formants performed better than those that use information across multiple formants (e.g., ``formant-extrinsic'' F2-F1). .

  7. A comparison of vowel normalization procedures for language variation research.

    PubMed

    Adank, Patti; Smits, Roel; van Hout, Roeland

    2004-11-01

    An evaluation of vowel normalization procedures for the purpose of studying language variation is presented. The procedures were compared on how effectively they (a) preserve phonemic information, (b) preserve information about the talker's regional background (or sociolinguistic information), and (c) minimize anatomical/physiological variation in acoustic representations of vowels. Recordings were made for 80 female talkers and 80 male talkers of Dutch. These talkers were stratified according to their gender and regional background. The normalization procedures were applied to measurements of the fundamental frequency and the first three formant frequencies for a large set of vowel tokens. The normalization procedures were evaluated through statistical pattern analysis. The results show that normalization procedures that use information across multiple vowels ("vowel-extrinsic" information) to normalize a single vowel token performed better than those that include only information contained in the vowel token itself ("vowel-intrinsic" information). Furthermore, the results show that normalization procedures that operate on individual formants performed better than those that use information across multiple formants (e.g., "formant-extrinsic" F2-F1).

  8. Evaluation of Hands-Free Devices for the Display of Maintenance Procedures

    NASA Technical Reports Server (NTRS)

    Whitmore, Mihriban; Hoffman, Ronald B.; Litaker, Harry, Jr.; Solem, Jody; Holden, Kritina; Twyford, Evan; Conlee, Carl

    2007-01-01

    Over the past year, NASA's focus has turned to crewed long duration and exploration missions. On these journeys, crewmembers will be required to execute thousands of procedures to maintain life support systems, check out space suits, conduct science experiments, and perform medical exams. To support the many complex tasks crewmembers undertake in microgravity, NASA is interested in providing crewmembers a hands-free work environment to promote more efficient operations. The overarching objective is to allow crewmembers to use both of their hands for tasks related to their mission, versus holding a paper manual or interacting with a display. The use of advanced, hands-free tools will undoubtedly make the crewmembers task easier, but they can also add to overall task complexity if not properly designed. A leading candidate technology for supporting a hands-free environment is the Head-Mounted Display (HMD). A more recent technology (e-book reader) that could be easily temp-stowed near the work area is also a potential hands-free solution. Previous work at NASA involved the evaluation of several commercially available HMDs for visual quality, comfort, and fit, as well as suitability for use in microgravity. Based on results from this work, three HMDs were selected for further evaluation (along with an e-book reader), using International Space Station (ISS)-like maintenance procedures. Two evaluations were conducted in the Space Station Mockup and Trainer Facility (SSMTF) located at the NASA Johnson Space Center (building 9). The SSMTF is a full scale, medium fidelity replica of the pressurized portions of the ISS. It supports crew training such as ingress and egress, habitability, and emergency procedures. In each of the two evaluations, the participants performed two maintenance procedures. One maintenance procedure involved inspecting air filters in a life support system and replacing them with a clean filter if one were found to be contaminated. The second maintenance procedure focused on working in a confined space; specifically, pulling down a rack to inspect wiring configurations, and rewiring in a different pattern. The maintenance procedures were selected to assess mobility, tool use, and access to multiple document sources during task performance. That is, the participant had to move from rack to rack, use a wrench, a camera, etc., replace components, and refer to diagrams to complete tasks. A constraint was imposed that the ISS-like format of the procedures was to be retained, and not modified or optimized for the electronic device ("plug and play" approach). This was based on future plans to test with real procedures on ISS.

  9. Application and Evaluation of an Expert Judgment Elicitation Procedure for Correlations.

    PubMed

    Zondervan-Zwijnenburg, Mariëlle; van de Schoot-Hubeek, Wenneke; Lek, Kimberley; Hoijtink, Herbert; van de Schoot, Rens

    2017-01-01

    The purpose of the current study was to apply and evaluate a procedure to elicit expert judgments about correlations, and to update this information with empirical data. The result is a face-to-face group elicitation procedure with as its central element a trial roulette question that elicits experts' judgments expressed as distributions. During the elicitation procedure, a concordance probability question was used to provide feedback to the experts on their judgments. We evaluated the elicitation procedure in terms of validity and reliability by means of an application with a small sample of experts. Validity means that the elicited distributions accurately represent the experts' judgments. Reliability concerns the consistency of the elicited judgments over time. Four behavioral scientists provided their judgments with respect to the correlation between cognitive potential and academic performance for two separate populations enrolled at a specific school in the Netherlands that provides special education to youth with severe behavioral problems: youth with autism spectrum disorder (ASD), and youth with diagnoses other than ASD. Measures of face-validity, feasibility, convergent validity, coherence, and intra-rater reliability showed promising results. Furthermore, the current study illustrates the use of the elicitation procedure and elicited distributions in a social science application. The elicited distributions were used as a prior for the correlation, and updated with data for both populations collected at the school of interest. The current study shows that the newly developed elicitation procedure combining the trial roulette method with the elicitation of correlations is a promising tool, and that the results of the procedure are useful as prior information in a Bayesian analysis.

  10. Effect of Spinal Manipulative Therapy on the Singing Voice.

    PubMed

    Fachinatto, Ana Paula A; Duprat, André de Campos; Silva, Marta Andrada E; Bracher, Eduardo Sawaya Botelho; Benedicto, Camila de Carvalho; Luz, Victor Botta Colangelo; Nogueira, Maruan Nogueira; Fonseca, Beatriz Suster Gomes

    2015-09-01

    This study investigated the effect of spinal manipulative therapy (SMT) on the singing voice of male individuals. Randomized, controlled, case-crossover trial. Twenty-nine subjects were selected among male members of the Heralds of the Gospel. This association was chosen because it is a group of persons with similar singing activities. Participants were randomly assigned to two groups: (A) chiropractic SMT procedure and (B) nontherapeutic transcutaneous electrical nerve stimulation (TENS) procedure. Recordings of the singing voice of each participant were taken immediately before and after the procedures. After a 14-day period, procedures were switched between groups: participants who underwent SMT on the first day were subjected to TENS and vice versa. Recordings were subjected to perceptual audio and acoustic evaluations. The same recording segment of each participant was selected. Perceptual audio evaluation was performed by a specialist panel (SP). Recordings of each participant were randomly presented thus making the SP blind to intervention type and recording session (before/after intervention). Recordings compiled in a randomized order were also subjected to acoustic evaluation. No differences in the quality of the singing on perceptual audio evaluation were observed between TENS and SMT. No differences in the quality of the singing voice of asymptomatic male singers were observed on perceptual audio evaluation or acoustic evaluation after a single spinal manipulative intervention of the thoracic and cervical spine. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  12. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  13. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  14. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  15. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  16. Federal Nondiscrimination Regulations: A Procedural Compliance Handbook. Draft.

    ERIC Educational Resources Information Center

    Governor's Committee on Employment of the Handicapped, Trenton, NJ.

    This handbook is designed to provide educators with the procedures and resources necessary to achieve compliance with Federal nondiscrimination regulations. The components of procedural compliance are examined as follows: (1) designation of a responsible coordinator; (2) institutional self-evaluation; (3) notification of nondiscrimination policy;…

  17. 34 CFR 303.303 - Referral procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the subject of a substantiated case of child abuse or neglect; or (2) Is identified as directly... DISABILITIES Child Find, Evaluations and Assessments, and Individualized Family Service Plans Referral Procedures § 303.303 Referral procedures. (a) General. (1) The lead agency's child find system described in...

  18. 34 CFR 303.303 - Referral procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the subject of a substantiated case of child abuse or neglect; or (2) Is identified as directly... DISABILITIES Child Find, Evaluations and Assessments, and Individualized Family Service Plans Referral Procedures § 303.303 Referral procedures. (a) General. (1) The lead agency's child find system described in...

  19. 34 CFR 303.303 - Referral procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the subject of a substantiated case of child abuse or neglect; or (2) Is identified as directly... DISABILITIES Child Find, Evaluations and Assessments, and Individualized Family Service Plans Referral Procedures § 303.303 Referral procedures. (a) General. (1) The lead agency's child find system described in...

  20. Identifying types of drug intoxication : laboratory evaluation of a subject-examination procedure

    DOT National Transportation Integrated Search

    1985-05-01

    The Los Angeles Police Department (LAPD) has developed a rating procedures for use in detecting drug-impaired drivers. The purpose of the rating procedures is to determine whether the driver is impaired and to identify the responsible drug class (e.g...

  1. People's Need for Additional Job Training: Development and Evaluation of an Assessment Procedure.

    ERIC Educational Resources Information Center

    Copa, George H.; Maurice, Clyde F.

    A procedure was developed and evaluated for assessing the self-perceived educational needs of people as one input to the process of planning, approving, and implementing relevant educational programs. The method of data collection involved selecting samples of people by randomly selecting households in a given geographic area, and then contacting…

  2. Information Exchange Procedures for Major Research Universities; Technical Diary of the Major Research Universities' Pilot Test.

    ERIC Educational Resources Information Center

    Topping, Jim

    The applicability and validity of NCHEMS' Information Exchange Procedures (IEP) to major research universities are examined. IEP enables peer institutions to compare information about their resources. Evaluation of the IEP costing methods are examined in this document, which is intended as an appendix to "Evaluation of the IEP Costing…

  3. 49 CFR Appendix C to Part 240 - Procedures for Obtaining and Evaluating Motor Vehicle Driving Record Data

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Evaluating Motor Vehicle Driving Record Data The purpose of this appendix is to outline the procedures... Vehicle Driving Record Data C Appendix C to Part 240 Transportation Other Regulations Relating to... that railroads consider the motor vehicle driving record of each person prior to issuing him or her...

  4. Methods to Evaluate Host Tree Suitability to the Asian Long horned Beetle, Anoplophora glabripennis

    Treesearch

    Scott W. Ludwig; Laura Lazarus; Deborah G. McCullough; Kelli Hoover; Silvia Montero; James C. Sellmer

    2002-01-01

    Two procedures were evaluated for assessing tree susceptibility to Anaplophora glabripennis. In the first procedure, adult beetles were caged with a section of sugar maple, northern red oak, white oak, honeylocust, eastern cottonwood, sycamore or tulip poplar wood Results showed that females laid viable eggs on sugar maple, red oak, white oak and...

  5. Technique for implanting radio transmitters subcutaneously in day-old ducklings

    USGS Publications Warehouse

    Korschgen, C.E.; Kenow, K.P.; Green, W.L.; Samuel, M.D.; Sileo, L.

    1996-01-01

    We developed and evaluated a surgical procedure for implanting radio transmitters in 1-d-old Canvasback (Aythya valisineria) ducklings. Transmitters (1.5 g) were implanted subcutaneously on the back of ducklings while under a general anesthetic, isoflurane, within a few hours of hatching. Evaluations indicate that the procedure is a reliable method for radio-marking ducklings.

  6. Manual of Procedures for Evaluation Visits under Standards for Accreditation, 1972. Revised 1977.

    ERIC Educational Resources Information Center

    American Library Association, Chicago, IL. Committee on Accreditation.

    This fully revised manual of procedures for evaluation visits presents guidelines for site visits to library schools seeking accreditation for their programs of study. Visits to such schools provide the Committee on Accreditation with data to assist in reaching a judgment whether to grant accredited status. The area of responsibility for the…

  7. Evaluation of Approval Request 47; Call for Release Procedures for Charlotte Douglas International Airport

    NASA Technical Reports Server (NTRS)

    Stevens, Lindsay; Martin, Lynne; Jobe, Kimberly; Parke, Bonny; Chevalley, Eric; Lee, Hanbong; Verma, Savita; Dulchinos, Victoria

    2017-01-01

    NASA is collaborating with the Federal Aviation Administration (FAA) and aviation industry partners to develop and demonstrate new concepts and technologies for Integrated Arrival, Departure, and Surface (IADS) traffic management capabilities under the Airspace Technology Demonstration 2 (ATD-2) project. One of the goals of the IADS capabilities in the ATD-2 project is to increase predictability and throughput of airspace operations by improving Traffic Management Initiative (TMI) compliance. This paper focuses on the Approval Request (APREQ) procedures developed for the ATD-2 project between the Air Traffic Control (ATC) Tower at Charlotte Douglas International Airport and Washington Center. In March 2017, NASA conducted a Human-in-the-Loop (HITL) simulation to evaluate the operational procedures and information requirements for the APREQ procedures in the ATD-2 IADS system between ATC Tower and Center. The findings from the HITL are used to compare ATD-2 APREQ procedures with information about current day APREQ procedures.

  8. Randomized study of surgical prophylaxis in immunocompromised hosts.

    PubMed

    Lopes, D R; Peres, M P S M; Levin, A S

    2011-02-01

    Although prophylaxis is current practice, there are no randomized controlled studies evaluating preoperative antimicrobial prophylaxis in dental procedures in patients immunocompromised by chemotherapy or organ transplants. To evaluate prophylaxis in dental-invasive procedures in patients with cancer or solid organ transplants, 414 patients were randomized to receive one oral 500-mg dose 2 hours before the procedure (1-dose group) or a 500-mg dose 2 hours before the procedure and an additional dose 8 hours later (2-dose group). Procedures were exodontia or periodontal scaling/root planing. Follow-up was 4 weeks. No deaths or surgical site infections occurred. Six patients (1.4%) presented with use of pain medication > 3 days or hospitalization during follow-up: 4 of 207 (2%) in the 1-dose group and 2 of 207 (1%) in the 2-dose group (relative risk, 2.02; 95% confidence interval, 0.37-11.15). In conclusion, no statistically significant difference occurred in outcome using 1 or 2 doses of prophylactic amoxicillin for invasive dental procedures in immunocompromised patients.

  9. Evaluation of Approval Request/Call for Release Coordination Procedures for Charlotte Douglas International Airport

    NASA Technical Reports Server (NTRS)

    Stevens, Lindsay; Martin, Lynne; Jobe, Kimberly; Parke, Bonny; Chevalley, Eric; Lee, Hanbong; Verma, Savita; Dulchinos, Victoria

    2017-01-01

    NASA is collaborating with the Federal Aviation Administration (FAA) and aviation industry partners to develop and demonstrate new concepts and technologies for Integrated Arrival, Departure, and Surface (IADS) traffic management capabilities under the Airspace Technology Demonstration 2 (ATD-2) project. One of the goals of the IADS capabilities in the ATD-2 project is to increase predictability and throughput of airspace operations by improving Traffic Management Initiative (TMI) compliance. This paper focuses on the Approval Request (APREQ) procedures developed for the ATD-2 project between the Air Traffic Control (ATC) Tower at Charlotte Douglas International Airport and Washington Center. In March 2017, NASA conducted a Human-in-the-Loop (HITL) simulation to evaluate the operational procedures and information requirements for the APREQ procedures in the ATD-2 IADS system between ATC Tower and Center. The findings from the HITL are used to compare ATD-2 APREQ procedures with information about current day APREQ procedures.

  10. ATLS: Catheter and tube placement

    NASA Technical Reports Server (NTRS)

    Gosbee, John; Krupa, Debra T.; Pepper, L.; Orsak, Debra

    1991-01-01

    The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.

  11. LocFuse: human protein-protein interaction prediction via classifier fusion using protein localization information.

    PubMed

    Zahiri, Javad; Mohammad-Noori, Morteza; Ebrahimpour, Reza; Saadat, Samaneh; Bozorgmehr, Joseph H; Goldberg, Tatyana; Masoudi-Nejad, Ali

    2014-12-01

    Protein-protein interaction (PPI) detection is one of the central goals of functional genomics and systems biology. Knowledge about the nature of PPIs can help fill the widening gap between sequence information and functional annotations. Although experimental methods have produced valuable PPI data, they also suffer from significant limitations. Computational PPI prediction methods have attracted tremendous attentions. Despite considerable efforts, PPI prediction is still in its infancy in complex multicellular organisms such as humans. Here, we propose a novel ensemble learning method, LocFuse, which is useful in human PPI prediction. This method uses eight different genomic and proteomic features along with four types of different classifiers. The prediction performance of this classifier selection method was found to be considerably better than methods employed hitherto. This confirms the complex nature of the PPI prediction problem and also the necessity of using biological information for classifier fusion. The LocFuse is available at: http://lbb.ut.ac.ir/Download/LBBsoft/LocFuse. The results revealed that if we divide proteome space according to the cellular localization of proteins, then the utility of some classifiers in PPI prediction can be improved. Therefore, to predict the interaction for any given protein pair, we can select the most accurate classifier with regard to the cellular localization information. Based on the results, we can say that the importance of different features for PPI prediction varies between differently localized proteins; however in general, our novel features, which were extracted from position-specific scoring matrices (PSSMs), are the most important ones and the Random Forest (RF) classifier performs best in most cases. LocFuse was developed with a user-friendly graphic interface and it is freely available for Linux, Mac OSX and MS Windows operating systems. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Improving conceptual and procedural knowledge: The impact of instructional content within a mathematics lesson.

    PubMed

    Rittle-Johnson, Bethany; Fyfe, Emily R; Loehr, Abbey M

    2016-12-01

    Students, parents, teachers, and theorists often advocate for direct instruction on both concepts and procedures, but some theorists suggest that including instruction on procedures in combination with concepts may limit learning opportunities and student understanding. This study evaluated the effect of instruction on a math concept and procedure within the same lesson relative to a comparable amount of instruction on the concept alone. Direct instruction was provided before or after solving problems to evaluate whether the type of instruction interacted with the timing of instruction within a lesson. We worked with 180 second-grade children in the United States. In a randomized experiment, children received a classroom lesson on mathematical equivalence in one of four conditions that varied in instruction type (conceptual or combined conceptual and procedural) and in instruction order (instruction before or after solving problems). Children who received two iterations of conceptual instruction had better retention of conceptual and procedural knowledge than children who received both conceptual and procedural instruction in the same lesson. Order of instruction did not impact outcomes. Findings suggest that within a single lesson, spending more time on conceptual instruction may be more beneficial than time spent teaching a procedure when the goal is to promote more robust understanding of target concepts and procedures. © 2016 The British Psychological Society.

  13. Public trust and confidence in legal authorities: What do majority and minority group members want from the law and legal institutions?

    PubMed

    Tyler, T R

    2001-01-01

    Discussions of public trust and confidence in the police and the courts often assume that the key to public feelings is the public's evaluation of the outcomes that the public receives from these legal authorities. In the case of the courts, discontent is often assumed to be linked to issues of cost and delay-instrumental concerns about the outcomes delivered to the public by the courts. In the case of the police, the inability to effectively control crime is frequently seen as driving public evaluations. This article presents an alternative procedural justice based model that links public trust and confidence to views about the manner in which legal authorities treat the public. Drawing upon psychological research about public evaluations of institutions and authorities it is argued that the key issue that shapes public views is a process based evaluation of the fairness of the procedures that the police and courts use to exercise their authority. Analyses from several studies exploring the basis of public views support this procedural justice based model of public evaluation. In addition, the results provide suggestions about the elements of procedures that are central to public judgments about their fairness. Copyright 2001 John Wiley & Sons, Ltd.

  14. Does the Timing of Pre-Operative Medical Evaluation Influence Perioperative Total Hip Arthroplasty Outcomes?

    PubMed

    Lan, Roy H; Kamath, Atul F

    2017-01-01

    Medical evaluation pre-operatively is an important component of risk stratification and potential risk optimization. However, the effect of timing prior to surgical intervention is not well-understood. We hypothesized that total hip arthroplasty (THA) patients seen in pre-operative evaluation closer to the date of surgery would experience better perioperative outcomes. We retrospectively reviewed 167 elective THA patients to study the relationship between the number of days between pre-operative evaluation (range, 0-80 days) and surgical intervention. Patients' demographics, length of stay (LOS), ICU admission frequency, and rate of major complications were recorded. When pre-operative evaluation carried out 4 days or less before the procedure date, there was a significant reduction in LOS (3.91 vs. 4.49; p=0.03). When pre-operative evaluation carried out 11 days or less prior to the procedure date, there was a four-fold decrease in rate of intensive care admission (p=0.04). Furthermore, the major complication rate also significantly reduced (p<0.05). However, when pre-operative evaluation took place 30 days or less before the procedure date compared to more than 30 days prior, there were no significant changes in the outcomes. From this study, pre-operative medical evaluation closer to the procedure date was correlated with improved selected peri-operative outcomes. However, further study on larger patient groups must be done to confirm this finding. More study is needed to define the effect on rare events like infection, and to analyze the subsets of THA patients with modifiable risk factors that may be time-dependent and need further time to optimization.

  15. Single-operator cholangioscopy in patients requiring evaluation of bile duct disease or therapy of biliary stones (with videos).

    PubMed

    Chen, Yang K; Parsi, Mansour A; Binmoeller, Kenneth F; Hawes, Robert H; Pleskow, Douglas K; Slivka, Adam; Haluszka, Oleh; Petersen, Bret T; Sherman, Stuart; Devière, Jacques; Meisner, Søren; Stevens, Peter D; Costamagna, Guido; Ponchon, Thierry; Peetermans, Joyce A; Neuhaus, Horst

    2011-10-01

    The feasibility of single-operator cholangioscopy (SOC) for biliary diagnostic and therapeutic procedures was previously reported. To confirm the utility of SOC in more widespread clinical use. Prospective clinical cohort study. Fifteen endoscopy referral centers in the United States and Europe. Two hundred ninety-seven patients requiring evaluation of bile duct disease or biliary stone therapy. SOC examination and, as indicated, SOC-directed stone therapy or forceps biopsy. Procedural success defined as ability to (1) visualize target lesions and, if indicated, collect biopsy specimens adequate for histological evaluation or (2) visualize biliary stones and initiate fragmentation and removal. The overall procedure success rate was 89% (95% CI, 84%-92%). Adequate tissue for histological examination was secured in 88% of 140 patients who underwent biopsy. Overall sensitivity in diagnosing malignancy was 78% for SOC visual impression and 49% for SOC-directed biopsy. Sensitivity was higher (84% and 66%, respectively) for intrinsic bile duct malignancies. Diagnostic SOC procedures altered clinical management in 64% of patients. Procedure success was achieved in 92% of 66 patients with stones and complete stone clearance during the study SOC session in 71%. The incidence of serious procedure-related adverse events was 7.5% for diagnostic SOC and 6.1% for SOC-directed stone therapy. The study was observational in design with no control group. Evaluation of bile duct disease and biliary stone therapy can be safely performed with a high success rate by using the SOC system. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. Evaluation plan for space station network interface units

    NASA Technical Reports Server (NTRS)

    Weaver, Alfred C.

    1990-01-01

    Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.

  17. Evaluating the benefits of government funded R & D aimed at the private sector

    NASA Technical Reports Server (NTRS)

    Greenberg, J. S.

    1977-01-01

    Federal funding of technological research and development is discussed with regard to the procedures for an economic analysis with the goals of (1) determining when the public sector should invest in a research and development program, (2) evaluating the likelihood of private sector participation in terms of public sector participation, and (3) considering the major factors in the formulation of a research and development program in terms of defining initiatives. Public sector investments are evaluated, noting procedures for determining whether benefits exceed costs. The role of the public sector research and development planning is described, considering the procedure for private sector implementation decisions and a methodology for evaluating the possibility of private sector commercialization. The economic value of the public sector research and development program is presented with attention given to a specific case of NASA-sponsored research and development aimed toward the commercialization of new public communications services.

  18. Advanced approach to the analysis of a series of in-situ nuclear forward scattering experiments

    NASA Astrophysics Data System (ADS)

    Vrba, Vlastimil; Procházka, Vít; Smrčka, David; Miglierini, Marcel

    2017-03-01

    This study introduces a sequential fitting procedure as a specific approach to nuclear forward scattering (NFS) data evaluation. Principles and usage of this advanced evaluation method are described in details and its utilization is demonstrated on NFS in-situ investigations of fast processes. Such experiments frequently consist of hundreds of time spectra which need to be evaluated. The introduced procedure allows the analysis of these experiments and significantly decreases the time needed for the data evaluation. The key contributions of the study are the sequential use of the output fitting parameters of a previous data set as the input parameters for the next data set and the model suitability crosscheck option of applying the procedure in ascending and descending directions of the data sets. Described fitting methodology is beneficial for checking of model validity and reliability of obtained results.

  19. Early detection of disease program: Evaluation of the cellular immune response

    NASA Technical Reports Server (NTRS)

    Criswell, B. S.; Knight, V.; Martin, R. R.; Kasel, J. A.

    1974-01-01

    The early cellular responses of specific components of the leukocyte and epithelial cell populations to foreign challenges of both an infectious and noninfectious character were evaluated. Procedures for screening potential flight crews were developed, documented, and tested on a control population. Methods for preparing suitable populations of lymphocytes, polymorphonuclear leukocytes, macrophages, and epithelial cells were first established and evaluated. Epithelial cells from viral infected individuals were screened with a number of anti-viral antisera. This procedure showed the earliest indication of disease as well as providing a specific diagnosis to the physicians. Both macrophages and polymorphonuclear leukocytes were studied from normal individuals, smokers, and patients with viral infections. Newer techniques enabling better definition of lymphocyte subpopulations were then developed, namely the E and EAC rosette procedures for recognition of T (thymus-derived) and B (bone-marrow-derived) lymphocyte subpopulations. Lymphocyte and lymphocyte subpopulation response to multiple mitogens have been evaluated.

  20. Refractory Metal Heat Pipe Life Test - Test Plan and Standard Operating Procedures

    NASA Technical Reports Server (NTRS)

    Martin, J. J.; Reid, R. S.

    2010-01-01

    Refractory metal heat pipes developed during this project shall be subjected to various operating conditions to evaluate life-limiting corrosion factors. To accomplish this objective, various parameters shall be investigated, including the effect of temperature and mass fluence on long-term corrosion rate. The test series will begin with a performance test of one module to evaluate its performance and to establish the temperature and power settings for the remaining modules. The performance test will be followed by round-the-clock testing of 16 heat pipes. All heat pipes shall be nondestructively inspected at 6-month intervals. At longer intervals, specific modules will be destructively evaluated. Both the nondestructive and destructive evaluations shall be coordinated with Los Alamos National Laboratory. During the processing, setup, and testing of the heat pipes, standard operating procedures shall be developed. Initial procedures are listed here and, as hardware is developed, will be updated, incorporating findings and lessons learned.

  1. Development of an improved overlay design procedure for Oregon : volume II, evaluation of procedure.

    DOT National Transportation Integrated Search

    1987-12-01

    This report is the second in a three-volume series dealing with the development of an improved overlay design procedure for Oregon. This report presents the results of the second-year findings. Data from five projects were collected and analyzed usin...

  2. Ottawa County Writing Process Model for PPO Assessments.

    ERIC Educational Resources Information Center

    Ottawa County Office of Education, OH.

    This guide outlines the writing procedures for English Composition Pupil Performance Objective (PPO) assessments and tests. Procedures for both students and teachers are included for the prewriting, first draft writing, and revising/rewriting sessions. A brief guide to evaluation procedures and intervention strategies is also provided. (MM)

  3. Evaluation of the procedure for separating barley from other spring small grains. [North Dakota, South Dakota, Minnesota and Montana

    NASA Technical Reports Server (NTRS)

    Magness, E. R. (Principal Investigator)

    1980-01-01

    The success of the Transition Year procedure to separate and label barley and the other small grains was assessed. It was decided that developers of the procedure would carry out the exercise in order to prevent compounding procedural problems with implementation problems. The evaluation proceeded by labeling the sping small grains first. The accuracy of this labeling was, on the average, somewhat better than that in the Transition Year operations. Other departures from the original procedure included a regionalization of the labeling process, the use of trend analysis, and the removal of time constraints from the actual processing. Segment selection, ground truth derivation, and data available for each segment in the analysis are discussed. Labeling accuracy is examined for North Dakota, South Dakota, Minnesota, and Montana as well as for the entire four-state area. Errors are characterized.

  4. Procedural techniques in sacral nerve modulation.

    PubMed

    Williams, Elizabeth R; Siegel, Steven W

    2010-12-01

    Sacral neuromodulation involves a staged process, including a screening trial and delayed formal implantation for those with substantial improvement. The advent of the tined lead has revolutionized the technology, allowing for a minimally invasive outpatient procedure to be performed under intravenous sedation. With the addition of fluoroscopy to the bilateral percutaneous nerve evaluation, there has been marked improvement in the placement of these temporary leads. Thus, the screening evaluation is now a better reflection of possible permanent improvement. Both methods of screening have advantages and disadvantages. Selection of a particular procedure should be tailored to individual patient characteristics. Subsequent implantation of the internal pulse generator (IPG) or explantation of an unsuccessful staged lead is straightforward outpatient procedure, providing minimal additional risk for the patient. Future refinement to the procedure may involve the introduction of a rechargeable battery, eliminating the need for IPG replacement at the end of the battery life.

  5. Evaluation of Currently Used Dental Management Indicators and Development of New Management and Performance Indicators.

    DTIC Science & Technology

    1981-07-01

    for selected procedures g. Pericdontal Procedures Per Dentist Formula: Number of Perio Procedures Comr’.neted* Nunber of Dentists Assigned *See appendi...02336 - Resin, Complex A-2 Selected Endodontic Procedures for Endo teeth per assigned DDS ratio: 03311 - Anterior, 1 Canal Filled 03312 - Anterior, 2 or...04271 - Free Soft Tissue Graft 04272 - Vestibulo.-lasty 04340 - Perio Scale and Root Planning *Some or these procedures are not end-item entities as are

  6. Cosmetic surgery procedures as luxury goods: measuring price and demand in facial plastic surgery.

    PubMed

    Alsarraf, Ramsey; Alsarraf, Nicole W; Larrabee, Wayne F; Johnson, Calvin M

    2002-01-01

    To evaluate the relationship between cosmetic facial plastic surgery procedure price and demand, and to test the hypothesis that these procedures function as luxury goods in the marketplace, with an upward-sloping demand curve. Data were derived from a survey that was sent to every (N = 1727) active fellow, member, or associate of the American Academy of Facial Plastic and Reconstructive Surgery, assessing the costs and frequency of 4 common cosmetic facial plastic surgery procedures (face-lift, brow-lift, blepharoplasty, and rhinoplasty) for 1999 and 1989. An economic analysis was performed to assess the relationship of price and demand for these procedures. A significant association was found between increasing surgeons' fees and total charges for cosmetic facial plastic surgery procedures and increasing demand for these procedures, as measured by their annual frequency (P

  7. Evaluation of modal pushover-based scaling of one component of ground motion: Tall buildings

    USGS Publications Warehouse

    Kalkan, Erol; Chopra, Anil K.

    2012-01-01

    Nonlinear response history analysis (RHA) is now increasingly used for performance-based seismic design of tall buildings. Required for nonlinear RHAs is a set of ground motions selected and scaled appropriately so that analysis results would be accurate (unbiased) and efficient (having relatively small dispersion). This paper evaluates accuracy and efficiency of recently developed modal pushover–based scaling (MPS) method to scale ground motions for tall buildings. The procedure presented explicitly considers structural strength and is based on the standard intensity measure (IM) of spectral acceleration in a form convenient for evaluating existing structures or proposed designs for new structures. Based on results presented for two actual buildings (19 and 52 stories, respectively), it is demonstrated that the MPS procedure provided a highly accurate estimate of the engineering demand parameters (EDPs), accompanied by significantly reduced record-to-record variability of the responses. In addition, the MPS procedure is shown to be superior to the scaling procedure specified in the ASCE/SEI 7-05 document.

  8. Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials: An Academic Research Consortium Initiative.

    PubMed

    Lansky, Alexandra J; Messé, Steven R; Brickman, Adam M; Dwyer, Michael; van der Worp, H Bart; Lazar, Ronald M; Pietras, Cody G; Abrams, Kevin J; McFadden, Eugene; Petersen, Nils H; Browndyke, Jeffrey; Prendergast, Bernard; Ng, Vivian G; Cutlip, Donald E; Kapadia, Samir; Krucoff, Mitchell W; Linke, Axel; Moy, Claudia Scala; Schofer, Joachim; van Es, Gerrit-Anne; Virmani, Renu; Popma, Jeffrey; Parides, Michael K; Kodali, Susheel; Bilello, Michel; Zivadinov, Robert; Akar, Joseph; Furie, Karen L; Gress, Daryl; Voros, Szilard; Moses, Jeffrey; Greer, David; Forrest, John K; Holmes, David; Kappetein, Arie P; Mack, Michael; Baumbach, Andreas

    2017-02-14

    Surgical and catheter-based cardiovascular procedures and adjunctive pharmacology have an inherent risk of neurological complications. The current diversity of neurological endpoint definitions and ascertainment methods in clinical trials has led to uncertainties in the neurological risk attributable to cardiovascular procedures and inconsistent evaluation of therapies intended to prevent or mitigate neurological injury. Benefit-risk assessment of such procedures should be on the basis of an evaluation of well-defined neurological outcomes that are ascertained with consistent methods and capture the full spectrum of neurovascular injury and its clinical effect. The Neurologic Academic Research Consortium is an international collaboration intended to establish consensus on the definition, classification, and assessment of neurological endpoints applicable to clinical trials of a broad range of cardiovascular interventions. Systematic application of the proposed definitions and assessments will improve our ability to evaluate the risks of cardiovascular procedures and the safety and effectiveness of preventive therapies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  9. PROC IRT: A SAS Procedure for Item Response Theory

    PubMed Central

    Matlock Cole, Ki; Paek, Insu

    2017-01-01

    This article reviews the procedure for item response theory (PROC IRT) procedure in SAS/STAT 14.1 to conduct item response theory (IRT) analyses of dichotomous and polytomous datasets that are unidimensional or multidimensional. The review provides an overview of available features, including models, estimation procedures, interfacing, input, and output files. A small-scale simulation study evaluates the IRT model parameter recovery of the PROC IRT procedure. The use of the IRT procedure in Statistical Analysis Software (SAS) may be useful for researchers who frequently utilize SAS for analyses, research, and teaching.

  10. Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 2: Patient Preparation and Medications)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com; Sebaaly, Mikhael Georges, E-mail: ms246@aub.edu.lb; Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb

    2016-04-15

    Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care. Patient care before and after an interventional procedure, identification, and management of early and delayed complications of various procedures are equal in importance to the procedure itself. In this second part, we complete the comprehensive, methodical review of pre-procedural care and patient preparation before vascular and interventional radiology procedures.

  11. Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 2: Patient Preparation and Medications).

    PubMed

    Taslakian, Bedros; Sebaaly, Mikhael Georges; Al-Kutoubi, Aghiad

    2016-04-01

    Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care. Patient care before and after an interventional procedure, identification, and management of early and delayed complications of various procedures are equal in importance to the procedure itself. In this second part, we complete the comprehensive, methodical review of pre-procedural care and patient preparation before vascular and interventional radiology procedures.

  12. Development of a systems theoretical procedure for evaluation of the work organization of the cockpit crew of a civil transport airplane

    NASA Technical Reports Server (NTRS)

    Fricke, M.; Vees, C.

    1983-01-01

    To achieve optimum design for the man machine interface with aircraft, a description of the interaction and work organization of the cockpit crew is needed. The development of system procedure to evaluate the work organization of pilots while structuring the work process is examined. Statistical data are needed to simulate sequences of pilot actions on the computer. Investigations of computer simulation and applicability for evaluation of crew concepts are discussed.

  13. Evaluation of results in aesthetic plastic surgery: preliminary observations on mammaplasty.

    PubMed

    Ferreira, M C

    2000-12-01

    Aesthetic plastic surgery has received wide public attention in the past few years. Expectations of patients regarding results have been exaggerated; the real place and medical importance of the procedures are still not clear because of a lack of more objective evidence. This study discusses the difficulties encountered related to the scientific evaluation of the aesthetic operations and proposes alternatives for assessment. A frequently performed procedure, reduction mammaplasty, is presented as an example, with its specific evaluation.

  14. A ruggedness evaluation of procedures for damage threshold testing optical materials

    NASA Technical Reports Server (NTRS)

    Hooker, Matthew W.; Thomas, Milfred E.; Wise, Stephanie A.; Tappan, Nina D.

    1995-01-01

    A ruggedness evaluation of approaches to damage threshold testing was performed to determine the influence of three procedural variables on damage threshold data. The differences between the number of test sites evaluated at an applied fluence level (1 site versus 10 sites), the number of laser pulses at each test site (1 pulse versus 200 pulses), and the beam diameter (0.35 mm versus 0.70 mm) were all found to significantly influence the damage threshold data over a 99-percent confidence interval.

  15. Integrating quantitative and qualitative evaluation methods to compare two teacher inservice training programs

    NASA Astrophysics Data System (ADS)

    Lawrenz, Frances; McCreath, Heather

    Qualitative and quantitative evaluation procedures were used to compare two physical-science teacher inservice training programs. The two programs followed the master teacher training model espoused by NSF but used different types of master teachers and types of activities. The two evaluation procedures produced different results and together they provided a much clearer picture of the strengths and weaknesses of the two programs. Using only one approach or the other would have substantially altered the conclusions.

  16. The Out of Service Guest Pilot Evaluation of the Two-segment Noise Abatement Approach in the Boeing B727-200

    NASA Technical Reports Server (NTRS)

    Nylen, W. E.

    1974-01-01

    Guest pilot evaluation results of an approach profile modification for reducing ground level noise under the approach of jet aircraft runways are reported. Evaluation results were used to develop a two segmented landing approach procedure and equipment necessary to obtain pilot, airline, and FAA acceptance of the two segmented flight as a routine way of operating aircraft on approach and landing. Data are given on pilot workload and acceptance of the procedure.

  17. A design procedure and handling quality criteria for lateral directional flight control systems

    NASA Technical Reports Server (NTRS)

    Stein, G.; Henke, A. H.

    1972-01-01

    A practical design procedure for aircraft augmentation systems is described based on quadratic optimal control technology and handling-quality-oriented cost functionals. The procedure is applied to the design of a lateral-directional control system for the F4C aircraft. The design criteria, design procedure, and final control system are validated with a program of formal pilot evaluation experiments.

  18. Self-reported "worth it" rating of aesthetic surgery in social media.

    PubMed

    Domanski, Mark C; Cavale, Naveen

    2012-12-01

    A wide variety of surveys have been used to validate the satisfaction of patients who underwent aesthetic surgery. However, such studies are often limited by patient number and number of surgeons. Social media now allows patients, on a large scale, to discuss and rate their satisfaction with procedures. The views of aesthetic procedures patients expressed in social media provide unique insight into patient satisfaction. The "worth it" percentage, average cost, and number of respondents were recorded on October 16, 2011, for all topics evaluated on the aesthetic procedure social media site www.realself.com . Procedures were divided into categories: surgical, liposuction, nonsurgical, and dental. For each group, procedures with the most respondents were chosen and ordered by "worth it" score. A literature search was performed for the most commonly rated surgical procedures and the satisfaction rates were compared. A total of 16,949 evaluations of 159 aesthetic surgery topics were recorded. A correlation between cost of the procedure and percentage of respondents indicating that the procedure was "worth it" was not found. The highest-rated surgical procedure was abdominoplasty, with 93 % of the 1,589 self-selected respondents expressing that abdominoplasty was "worth it." The average self-reported cost was $8,400. The highest-rated nonsurgical product was Latisse, with 85 % of 231 respondents reporting it was "worth it" for an average cost of $200. The satisfaction scores in the literature for commonly rated surgical procedures ranged from 62 to 97.6 %. No statistically significant correlations between literature satisfaction scores and realself.com "worth it" scores were found. Abdominoplasty had the highest "worth it" rating among aesthetic surgical procedures. Aesthetic surgeons should be wary that satisfaction scores reported in the literature might not correlate with commonly achieved results. Social media has opened a new door into how procedures are evaluated and perceived. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the table of contents or the online instructions to authors www.springer.com/00266 .

  19. Research Reports. Seven Reports of the Project to Develop Evaluative Criteria and Procedures for the Accreditation of Nontraditional Education. Volume 2.

    ERIC Educational Resources Information Center

    Andersen, Kay J.; And Others

    Seven research reports of the Project to Develop Evaluative Criteria and Procedures for the Accreditation of Nontraditional Education are presented. Contents are as follows: "Nontraditional Certificate Programs," by John Harris and Philip N. McCullough; "Salient Points for 'A Study of the Acceptability and Negotiability of External Degrees,'" by…

  20. 9 CFR 147.16 - Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... mycoplasma reactors by in vivo bio-assay (enrichment). 147.16 Section 147.16 Animals and Animal Products... the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). This procedure has been shown... publications: (a) Bigland, C. H. and A. J. DaMassa, “A Bio-Assay for Mycoplasma Gallisepticum.” In: United...

  1. 9 CFR 147.16 - Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... mycoplasma reactors by in vivo bio-assay (enrichment). 147.16 Section 147.16 Animals and Animal Products... the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). This procedure has been shown... publications: (a) Bigland, C. H. and A. J. DaMassa, “A Bio-Assay for Mycoplasma Gallisepticum.” In: United...

  2. 9 CFR 147.16 - Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... mycoplasma reactors by in vivo bio-assay (enrichment). 147.16 Section 147.16 Animals and Animal Products... the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). This procedure has been shown... publications: (a) Bigland, C. H. and A. J. DaMassa, “A Bio-Assay for Mycoplasma Gallisepticum.” In: United...

  3. Teacher Evaluation, Pay for Performance, and Learning around Instruction: Between Dissonant Incentives and Resonant Procedures

    ERIC Educational Resources Information Center

    Mintrop, Rick; Ordenes, Miguel; Coghlan, Erin; Pryor, Laura; Madero, Cristobal

    2018-01-01

    Purpose: The study examines why the logic of a performance management system, supported by the federal Teacher Incentive Fund, might be faulty. It does this by exploring the nuances of the interplay between teaching evaluations as formative and summative, the use of procedures, tools, and artifacts obligated by the local Teacher Incentive Fund…

  4. Evaluating the Effectiveness of the Stimulus Pairing Observation Procedure and Multiple Exemplar Instruction on Tact and Listener Responses in Children with Autism

    ERIC Educational Resources Information Center

    Byrne, Brittany L.; Rehfeldt, Ruth Anne; Aguirre, Angelica A.

    2014-01-01

    The stimulus pairing observation procedure (SPOP) combined with multiple exemplar instruction (MEI) has been shown to be effective with typically developing preschoolers in establishing the joint stimulus control required for the development of naming. The purpose of the current investigation was to evaluate the effectiveness and efficiency of the…

  5. Winning Public Support of a Desegregated School System. Title III ESEA Progress Report, School District 151 (South Holland, Illinois).

    ERIC Educational Resources Information Center

    South Holland School District 151, IL.

    Thirteen objectives of the program and analyses of each in terms of procedure, evaluation, the status of procedure, and status of the evaluation are listed in this report. The objectives are: the establishment of a community relations program to promote two-way communication between school board, administration, teachers, students, and parents;…

  6. 9 CFR 147.16 - Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... mycoplasma reactors by in vivo bio-assay (enrichment). 147.16 Section 147.16 Animals and Animal Products... the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). This procedure has been shown... publications: (a) Bigland, C. H. and A. J. DaMassa, “A Bio-Assay for Mycoplasma Gallisepticum.” In: United...

  7. Improvement of screening methods for silicon planar semiconductor devices

    NASA Technical Reports Server (NTRS)

    Berger, W. M.

    1972-01-01

    The results of the program for the development of a more sensitive method for selecting silicon planar semiconductor devices for long life applications are reported. The manufacturing technologies (MOS and Bipolar) are discussed along with the screening procedures developed as a result of the tests and evaluations, and the effectiveness of the MOS and Bilayer screening procedures are evaluated.

  8. 30 CFR 253.28 - What financial test procedures must I use to evaluate the amount of self-insurance allowed as...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What financial test procedures must I use to evaluate the amount of self-insurance allowed as OSFR evidence based on unencumbered assets? 253.28 Section 253.28 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL SPILL...

  9. Evaluation of interlayer interfacial stiffness and layer wave velocity of multilayered structures by ultrasonic spectroscopy.

    PubMed

    Ishii, Yosuke; Biwa, Shiro

    2014-07-01

    An ultrasonic evaluation procedure for the interlayer interfacial normal stiffness and the intralayer longitudinal wave velocity of multilayered plate-like structures is proposed. Based on the characteristics of the amplitude reflection spectrum of ultrasonic wave at normal incidence to a layered structure with spring-type interlayer interfaces, it is shown that the interfacial normal stiffness and the longitudinal wave velocity in the layers can be simultaneously evaluated from the frequencies of local maxima and minima of the spectrum provided that all interfaces and layers have the same properties. The effectiveness of the proposed procedure is investigated from the perspective of the sensitivity of local extremal frequencies of the reflection spectrum. The feasibility of the proposed procedure is also investigated when the stiffness of each interface is subjected to small random fluctuations about a certain average value. The proposed procedure is applied to a 16-layered cross-ply carbon-fiber-reinforced composite laminate. The normal stiffness of resin-rich interfaces and the longitudinal wave velocity of plies in the thickness direction evaluated from the experimental reflection spectrum are shown to be consistent with simple theoretical estimations.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frame, E.A.

    The objectives of this project were: (1) to determine the feasibility of adding a vapor-phase corrosion inhibitor (VCI) component to improve the preservation performance of MIL-L-21260 and (2) to evaluate a less complicated engine preservation procedure. A simultaneous two-phase approach was conducted. Phase 1 involved the formulation and evaluation of experimental VCI oils, while Phase 2 was the evaluation of a simplified engine preservation procedure. VCI oil formulation was conducted by Ronco Laboratory under subcontract. Compatibility of the experimental VCI oils with metal coupons, elastomers, and fuel filters was determined. Effectiveness of the experimental VCI oil was evaluated in amore » 3-year outdoor engine storage test. The engines were preserved using an experimental, simplified preservation procedure. The simplified engine preservation procedure proved to be acceptable as engines stored for 3 years in a very severe environment were judged to have been adequately preserved. Engine oil meeting specification MIL-L-21260 provided satisfactory protection during the 3-year storage test. The experimental VCI oil also provided satisfactory storage protection during this test; however, there was no observable advantage for the VCI oil. The VCI oil had acceptable compatibility with an elastomeric flex ring, metal coupons (except lead), and fuel filters.« less

  11. Technical Criteria and Procedures for Evaluating the Crashworthiness and Occupant Protection Performance of Alternatively Designed Passenger Rail Equipment for Use in Tier I Service

    DOT National Transportation Integrated Search

    2011-10-01

    Criteria and procedures have been developed for assessing crashworthiness and occupant protection performance of alternatively designed trainsets to be used in Tier I (not exceeding 125 mph) passenger service. These criteria and procedures take advan...

  12. 19 CFR 101.9 - Test programs or procedures; alternate requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2010-04-01 2010-04-01 false Test programs or procedures; alternate...

  13. 19 CFR 101.9 - Test programs or procedures; alternate requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2013-04-01 2013-04-01 false Test programs or procedures; alternate...

  14. 19 CFR 101.9 - Test programs or procedures; alternate requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2011-04-01 2011-04-01 false Test programs or procedures; alternate...

  15. 19 CFR 101.9 - Test programs or procedures; alternate requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... requirements. (a) General testing. For purposes of conducting a test program or procedure designed to evaluate... test and the basis for selecting participants; and, (2) Post publication requirement. Within a... 19 Customs Duties 1 2012-04-01 2012-04-01 false Test programs or procedures; alternate...

  16. Evaluation of the CATSIB DIF Procedure in a Pretest Setting

    ERIC Educational Resources Information Center

    Nandakumar, Ratna; Roussos, Louis

    2004-01-01

    A new procedure, CATSIB, for assessing differential item functioning (DIF) on computerized adaptive tests (CATs) is proposed. CATSIB, a modified SIBTEST procedure, matches test takers on estimated ability and controls for impact-induced Type 1 error inflation by employing a CAT version of the IBTEST "regression correction." The…

  17. 48 CFR 225.7703-1 - Acquisition procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Operations in Iraq or Afghanistan 225.7703-1 Acquisition procedures. (a) Subject to the requirements of 225... in Iraq or Afghanistan, may be acquired by— (1) Providing a preference for products or services from Iraq or Afghanistan in accordance with the evaluation procedures at 225.7703-3; (2) Limiting...

  18. 78 FR 37548 - Agency Information Collection Activities: Proposed Collection; Comment Request; Guidance for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... in Sec. 211.100(b); and standard operating procedures should be reviewed and revised or supplementary... manufacturers to include a procedure in their Plan for notifying the Center for Drug Evaluation and Research... drug products will be manufactured under altered procedures, which products will have manufacturing...

  19. The Psychophysics of Contingency Assessment

    ERIC Educational Resources Information Center

    Allan, Lorraine G.; Hannah, Samuel D.; Crump, Matthew J. C.; Siegel, Shepard

    2008-01-01

    The authors previously described a procedure that permits rapid, multiple within-participant evaluations of contingency assessment (the "streamed-trial" procedure, M. J. C. Crump, S. D. Hannah, L. G. Allan, & L. K. Hord, 2007). In the present experiments, they used the streamed-trial procedure, combined with the method of constant stimuli and a…

  20. 48 CFR 225.872-3 - Solicitation procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... test and evaluation standards, policies, and procedures when the department or agency decides that... requirements. When practical, structure these meetings to allow attendance by representatives of qualifying...

  1. Using the arthroscopic surgery skill evaluation tool as a pass-fail examination.

    PubMed

    Koehler, Ryan J; Nicandri, Gregg T

    2013-12-04

    Examination of arthroscopic skill requires evaluation tools that are valid and reliable with clear criteria for passing. The Arthroscopic Surgery Skill Evaluation Tool was developed as a video-based assessment of technical skill with criteria for passing established by a panel of experts. The purpose of this study was to test the validity and reliability of the Arthroscopic Surgery Skill Evaluation Tool as a pass-fail examination of arthroscopic skill. Twenty-eight residents and two sports medicine faculty members were recorded performing diagnostic knee arthroscopy on a left and right cadaveric specimen in our arthroscopic skills laboratory. Procedure videos were evaluated with use of the Arthroscopic Surgery Skill Evaluation Tool by two raters blind to subject identity. Subjects were considered to pass the Arthroscopic Surgery Skill Evaluation Tool when they attained scores of ≥ 3 on all eight assessment domains. The raters agreed on a pass-fail rating for fifty-five of sixty videos rated with an interclass correlation coefficient value of 0.83. Ten of thirty participants were assigned passing scores by both raters for both diagnostic arthroscopies performed in the laboratory. Receiver operating characteristic analysis demonstrated that logging more than eighty arthroscopic cases or performing more than thirty-five arthroscopic knee cases was predictive of attaining a passing Arthroscopic Surgery Skill Evaluation Tool score on both procedures performed in the laboratory. The Arthroscopic Surgery Skill Evaluation Tool is valid and reliable as a pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. This study demonstrates that the Arthroscopic Surgery Skill Evaluation Tool may be a useful tool for pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Further study is necessary to determine whether the Arthroscopic Surgery Skill Evaluation Tool can be used for the assessment of multiple arthroscopic procedures and whether it can be used to evaluate arthroscopic procedures performed in the operating room.

  2. On the optical evaluation of the EL2 deep level concentration in semi-insulating GaAs

    NASA Technical Reports Server (NTRS)

    Walukiewicz, W.; Lagowski, J.; Gatos, H. C.

    1983-01-01

    A practical procedure for the evaluation of the Fermi energy in semi-insulating (SI)GaAs from electrical measurements is presented. This procedure makes it possible to reliably extend the determination of the major deep level (EL2) concentration, by near-infrared absorption measurements, to SIGaAs. Employing this procedure, it is shown that the EL2 concentration in Czochralski-grown GaAs increases monotonically with increasing As/Ga ratio (throughout the conversion from SI n type to semiconducting p-type crystals) rather than abruptly as previously proposed.

  3. A web-based procedure for liver segmentation in CT images

    NASA Astrophysics Data System (ADS)

    Yuan, Rong; Luo, Ming; Wang, Luyao; Xie, Qingguo

    2015-03-01

    Liver segmentation in CT images has been acknowledged as a basic and indispensable part in systems of computer aided liver surgery for operation design and risk evaluation. In this paper, we will introduce and implement a web-based procedure for liver segmentation to help radiologists and surgeons get an accurate result efficiently and expediently. Several clinical datasets are used to evaluate the accessibility and the accuracy. This procedure seems a promising approach for extraction of liver volumetry of various shapes. Moreover, it is possible for user to access the segmentation wherever the Internet is available without any specific machine.

  4. Procedures for Comparing Instructional Programs.

    ERIC Educational Resources Information Center

    Klein, Stephen

    This paper examines comparative educational program evaluation. Suggested evaluative criteria and evaluation techniques and their weaknesses are discussed. An evaluation formula is proposed, and an example of its operation is provided. (DG)

  5. Digital I and C system upgrade integration technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, H. W.; Shih, C.; Wang, J. R.

    2012-07-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digitalmore » Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A solid review can assure the quality of the digital I and C system replacement. (authors)« less

  6. Comparison of Clinical Outcomes of Scarf and Chevron Osteotomies and the McBride Procedure in the Treatment of Hallux Valgus Deformity

    PubMed Central

    Fakoor, Mohammad; Sarafan, Naser; Mohammadhoseini, Payam; Khorami, Mohsen; Arti, Hamidreza; Mosavi, SeyedShahnam; Aghaeeaghdam, Amir

    2014-01-01

    Background: Hallux valgus deformity is a common chronic problem with a reported prevalence of 28.4% and its chief complaint is pain. Thus far, different surgical procedures with their proposed indications have been introduced. This study compared three current procedures, namely the chevron and scarf osteotomies and the McBride procedure. Methods: This retrospective cohort was conducted at the Ahvaz University of Medical Sciences on 44 patients with moderate hallux valgus deformity from 2010 and 2013. All of the patients underwent one of the three procedures (chevron, scarf or McBride). Preoperative and follow up radiographies were evaluated in terms of hallux valgus and intermetatarsal angle correction. The Foot and Ankle Disability Index was filled out to assess the functional outcome and the Visual Analogue Scale was used to evaluate pain. Also, satisfaction, aesthetics and the rate of recurrence was evaluated. Results: Hallux valgus angle and intermetatarsal angle correction were significantly higher in scarf, but not in chevron and McBride. However, from amongst the three procedures, there was no significant difference in terms of the Foot and Ankle Disability Index score, aesthetics, satisfaction level, pain score and recurrence rate. Conclusions: Considering that scarf osteotomy had better results in this study, we think that scarf osteotomy can be considered as a first choice for the treatment of moderate hallux valgus deformity. PMID:25207310

  7. Comparison of Clinical Outcomes of Scarf and Chevron Osteotomies and the McBride Procedure in the Treatment of Hallux Valgus Deformity.

    PubMed

    Fakoor, Mohammad; Sarafan, Naser; Mohammadhoseini, Payam; Khorami, Mohsen; Arti, Hamidreza; Mosavi, SeyedShahnam; Aghaeeaghdam, Amir

    2014-03-01

    Hallux valgus deformity is a common chronic problem with a reported prevalence of 28.4% and its chief complaint is pain. Thus far, different surgical procedures with their proposed indications have been introduced. This study compared three current procedures, namely the chevron and scarf osteotomies and the McBride procedure. This retrospective cohort was conducted at the Ahvaz University of Medical Sciences on 44 patients with moderate hallux valgus deformity from 2010 and 2013. All of the patients underwent one of the three procedures (chevron, scarf or McBride). Preoperative and follow up radiographies were evaluated in terms of hallux valgus and intermetatarsal angle correction. The Foot and Ankle Disability Index was filled out to assess the functional outcome and the Visual Analogue Scale was used to evaluate pain. Also, satisfaction, aesthetics and the rate of recurrence was evaluated. Hallux valgus angle and intermetatarsal angle correction were significantly higher in scarf, but not in chevron and McBride. However, from amongst the three procedures, there was no significant difference in terms of the Foot and Ankle Disability Index score, aesthetics, satisfaction level, pain score and recurrence rate. Considering that scarf osteotomy had better results in this study, we think that scarf osteotomy can be considered as a first choice for the treatment of moderate hallux valgus deformity.

  8. Predictive factors for outcomes of patients undergoing endoscopic therapy for bile leak after hepatobiliary surgery.

    PubMed

    Yabe, Shuntaro; Kato, Hironari; Mizukawa, Sho; Akimoto, Yutaka; Uchida, Daisuke; Seki, Hiroyuki; Tomoda, Takeshi; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki

    2017-05-01

    Endoscopic procedures are used as first-line treatment for bile leak after hepatobiliary surgery. Advances have been made in endoscopic techniques and devices, but few reports have described the effectiveness of endoscopic procedures and the management principles based on severity of bile leak. We evaluated the effectiveness of an endoscopic procedure for the treatment of bile leak after hepatobiliary surgery. Fifty-eight patients underwent an endoscopic procedure for suspected bile leak after hepatobiliary surgery; the presence of bile leak on endoscopic retrograde cholangiopancreatography (ERCP) was evaluated retrospectively. Two groups were created based on bile leak severity at ERCP. We defined success as follows: technical, successful placement of the plastic stent at the intended bile duct; clinical, improvement in symptoms of bile leak; and eventual, disappearance of bile leak at ERCP. We evaluated several factors that influenced the success of the endoscopic procedure and the differences between bile leak severity. Success rates were as follows: technical, 90%; clinical, 79%; and eventual, 71%. Median interval between first endoscopic procedure and achievement of eventual success was 135 days (IQR, 86-257 days). Bile leak severity was the only independent factor associated with eventual success (P = 0.01). Endoscopic therapy is safe and effective for postoperative bile leak. Bile leak severity is the most important factor influencing successful endoscopic therapy. © 2016 Japan Gastroenterological Endoscopy Society.

  9. Evaluation of solution procedures for material and/or geometrically nonlinear structural analysis by the direct stiffness method.

    NASA Technical Reports Server (NTRS)

    Stricklin, J. A.; Haisler, W. E.; Von Riesemann, W. A.

    1972-01-01

    This paper presents an assessment of the solution procedures available for the analysis of inelastic and/or large deflection structural behavior. A literature survey is given which summarized the contribution of other researchers in the analysis of structural problems exhibiting material nonlinearities and combined geometric-material nonlinearities. Attention is focused at evaluating the available computation and solution techniques. Each of the solution techniques is developed from a common equation of equilibrium in terms of pseudo forces. The solution procedures are applied to circular plates and shells of revolution in an attempt to compare and evaluate each with respect to computational accuracy, economy, and efficiency. Based on the numerical studies, observations and comments are made with regard to the accuracy and economy of each solution technique.

  10. A study of the stress wave factor technique for evaluation of composite materials

    NASA Technical Reports Server (NTRS)

    Duke, J. C., Jr.; Henneke, E. G., II; Kiernan, M. T.; Grosskopf, P. P.

    1989-01-01

    The acousto-ultrasonic approach for nondestructive evaluation provides a measurement procedure for quantifying the integrated effect of globally distributed damage characteristic of fiber reinforced composite materials. The evaluation procedure provides a stress wave factor that correlates closely with several material performance parameters. The procedure was investigated for a variety of materials including advanced composites, hybrid structure bonds, adhesive bonds, wood products, and wire rope. The research program focused primarily on development of fundamental understanding and applications advancements of acousto-ultrasonics for materials characterization. This involves characterization of materials for which detection, location, and identification of imperfections cannot at present be analyzed satisfactorily with mechanical performance prediction models. In addition to presenting definitive studies on application potentials, the understanding of the acousto-ultrasonic method as applied to advanced composites is reviewed.

  11. 34 CFR 303.323 - Nondiscriminatory procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Services Identification and Evaluation § 303.323 Nondiscriminatory procedures. Each lead agency shall adopt... qualified personnel. (Approved by the Office of Management and Budget under control number 1820-0550...

  12. Magnetic navigation in ultrasound-guided interventional radiology procedures.

    PubMed

    Xu, H-X; Lu, M-D; Liu, L-N; Guo, L-H

    2012-05-01

    To evaluate the usefulness of magnetic navigation in ultrasound (US)-guided interventional procedures. Thirty-seven patients who were scheduled for US-guided interventional procedures (20 liver cancer ablation procedures and 17 other procedures) were included. Magnetic navigation with three-dimensional (3D) computed tomography (CT), magnetic resonance imaging (MRI), 3D US, and position-marking magnetic navigation were used for guidance. The influence on clinical outcome was also evaluated. Magnetic navigation facilitated applicator placement in 15 of 20 ablation procedures for liver cancer in which multiple ablations were performed; enhanced guidance in two small liver cancers invisible on conventional US but visible at CT or MRI; and depicted the residual viable tumour after transcatheter arterial chemoembolization for liver cancer in one procedure. In four of 17 other interventional procedures, position-marking magnetic navigation increased the visualization of the needle tip. Magnetic navigation was beneficial in 11 (55%) of 20 ablation procedures; increased confidence but did not change management in five (25%); added some information but did not change management in two (10%); and made no change in two (10%). In the other 17 interventional procedures, the corresponding numbers were 1 (5.9%), 2 (11.7%), 7 (41.2%), and 7 (41.2%), respectively (p=0.002). Magnetic navigation in US-guided interventional procedure provides solutions in some difficult cases in which conventional US guidance is not suitable. It is especially useful in complicated interventional procedures such as ablation for liver cancer. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  14. Adsorption of 99mTc-sestamibi onto plastic syringes: evaluation of factors affecting the degree of adsorption and their impact on clinical studies.

    PubMed

    Swanson, Tiffinee N; Troung, Duong T; Paulsen, Andrew; Hruska, Carrie B; O'Connor, Michael K

    2013-12-01

    The purpose of this study was to document the extent of adhesion of (99m)Tc-sestamibi to syringes in patient procedures, determine factors that influence the degree of adhesion, and evaluate alternatives to our current practice that would either result in a more reproducible degree of adhesion or, ideally, eliminate adhesion. The extent of adhesion was documented in 216 patient procedures and evaluated in detail in an additional 73 patient procedures. We evaluated the nature of the adhesion and its possible causes, including the location of adhesion in injection sets, the effect of syringe type, and the effect of prerinsing of syringes with various solutions of nonradiolabeled sestamibi and (99m)Tc-sestamibi. The extent of adhesion was reevaluated in 50 procedures performed using the syringe type that demonstrated the lowest adhesion rate. The degree of adhesion of (99m)Tc-sestamibi to the injection set was found to be 20.1% ± 8.0%, with a range (10th-90th percentiles) of 9%-31%. The primary cause of adhesion appeared to be the lubricant used inside the syringe barrel. Evaluation of 6 different syringe types identified a brand with a lower adhesion rate. Reevaluation in patient procedures using this brand showed a 5.2% ± 2.5% degree of adhesion, with a range (10th-90th percentiles) of 2.5%-7.7%. Selection of the appropriate type of syringe can significantly reduce the magnitude and variability of residual (99m)Tc-sestamibi activity. With more reproducible residual activities, we have been able to achieve an approximately 20% reduction in the dispensed dose of (99m)Tc-sestamibi used in clinical procedures and a more consistent injected dose with less interpatient variation. The frequent changes in syringe design by manufacturers require that a quality control program for monitoring of residual activity be incorporated into clinical practice. This program has allowed us to maintain image quality and achieve more consistent injected patient doses in clinical procedures that use (99m)Tc-sestamibi.

  15. Assessing residents' operative skills for external ventricular drain placement and shunt surgery in pediatric neurosurgery.

    PubMed

    Aldave, Guillermo; Hansen, Daniel; Briceño, Valentina; Luerssen, Thomas G; Jea, Andrew

    2017-04-01

    OBJECTIVE The authors previously demonstrated the use of a validated Objective Structured Assessment of Technical Skills (OSATS) tool for evaluating residents' operative skills in pediatric neurosurgery. However, no benchmarks have been established for specific pediatric procedures despite an increased need for meaningful assessments that can either allow for early intervention for underperforming trainees or allow for proficient residents to progress to conducting operations independently with more passive supervision. This validated methodology and tool for assessment of operative skills for common pediatric neurosurgical procedures-external ventricular drain (EVD) placement and shunt surgery- was applied to establish its procedure-based feasibility and reliability, and to document the effect of repetition on achieving surgical skill proficiency in pediatric EVD placement and shunt surgery. METHODS A procedure-based technical skills assessment for EVD placements and shunt surgeries in pediatric neurosurgery was established through the use of task analysis. The authors enrolled all residents from 3 training programs (Baylor College of Medicine, Houston Methodist Hospital, and University of Texas-Medical Branch) who rotated through pediatric neurosurgery at Texas Children's Hospital over a 26-month period. For each EVD placement or shunt procedure performed with a resident, the faculty and resident (for self-assessment) completed an evaluation form (OSATS) based on a 5-point Likert scale with 7 categories. Data forms were then grouped according to faculty versus resident (self) assessment, length of pediatric neurosurgery rotation, postgraduate year level, and date of evaluation ("beginning of rotation," within 1 month of start date; "end of rotation," within 1 month of completion date; or "middle of rotation"). Descriptive statistical analyses were performed with the commercially available SPSS statistical software package. A p value < 0.05 was considered statistically significant. RESULTS Five attending evaluators (including 2 fellows who acted as attending surgeons) completed 260 evaluations. Twenty house staff completed 269 evaluations for self-assessment. Evaluations were completed in 562 EVD and shunt procedures before the surgeons left the operating room. There were statistically significant differences (p < 0.05) between overall attending (mean 4.3) and junior resident (self; mean 3.6) assessments, and between overall attending (mean 4.8) and senior resident (self; mean 4.6) assessment scores on general performance and technical skills. The learning curves produced for the residents demonstrate a stereotypical U- or V-shaped curve for acquiring skills, with a significant improvement in overall scores at the end of the rotation compared with the beginning. The improvement for junior residents (Δ score = 0.5; p = 0.002) was larger than for senior residents (Δ score = 0.2; p = 0.018). CONCLUSIONS The OSATS is an effective assessment tool as part of a comprehensive evaluation of neurosurgery residents' performance for specific pediatric procedures. The authors observed a U-shaped learning curve, contradicting the idea that developing one's surgical technique and learning a procedure represents a monotonic, cumulative process of repetitions and improvement.

  16. The Next Step in Deployment of Computer Based Procedures For Field Workers: Insights And Results From Field Evaluations at Nuclear Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oxstrand, Johanna; Le Blanc, Katya L.; Bly, Aaron

    The paper-based procedures currently used for nearly all activities in the commercial nuclear power industry have a long history of ensuring safe operation of the plants. However, there is potential to greatly increase efficiency and safety by improving how the human operator interacts with the procedures. One way to achieve these improvements is through the use of computer-based procedures (CBPs). A CBP system offers a vast variety of improvements, such as context driven job aids, integrated human performance tools (e.g., placekeeping, correct component verification, etc.), and dynamic step presentation. The latter means that the CBP system could only display relevantmore » steps based on operating mode, plant status, and the task at hand. A dynamic presentation of the procedure (also known as context-sensitive procedures) will guide the operator down the path of relevant steps based on the current conditions. This feature will reduce the operator’s workload and inherently reduce the risk of incorrectly marking a step as not applicable and the risk of incorrectly performing a step that should be marked as not applicable. The research team at the Idaho National Laboratory has developed a prototype CBP system for field workers, which has been evaluated from a human factors and usability perspective in four laboratory studies. Based on the results from each study revisions were made to the CBP system. However, a crucial step to get the end users' (e.g., auxiliary operators, maintenance technicians, etc.) acceptance is to put the system in their hands and let them use it as a part of their everyday work activities. In the spring 2014 the first field evaluation of the INL CBP system was conducted at a nuclear power plant. Auxiliary operators conduct a functional test of one out of three backup air compressors each week. During the field evaluation activity, one auxiliary operator conducted the test with the paper-based procedure while a second auxiliary operator followed along with the computer-based procedure. After each conducted functional test the operators were asked a series of questions designed to provide feedback on the feasibility to use a CBP system in the plant and the general user experience of the CBP system. This paper will describe the field evaluation and its results in detail. For example, the result shows that the context driven job aids and the incorporated human performance tools are much liked by the auxiliary operators. The paper will describe and present initial findings from a second field evaluation conducted at second nuclear utility. For this field evaluation a preventive maintenance work order for the HVAC system was used. In addition, there will be a description of the method and objective of two field evaluations planned to be conducted late 2014 or early 2015.« less

  17. [From Science to Law: Findings of Reha XI Project on Ascertaining the Need for Rehabilitation in Medical Service Assessments].

    PubMed

    Kalwitzki, T; Huter, K; Runte, R; Breuninger, K; Janatzek, S; Gronemeyer, S; Gansweid, B; Rothgang, H

    2017-03-01

    Introduction: In the broad-based consortium project "Reha XI - Identifying rehabilitative requirements in medical service assessments: evaluation and implementation", a comprehensive analysis of the corresponding procedures was carried out by the medical services of the German Health Insurance Funds (MDK). On the basis of this analysis, a Good Practice Standard (GPS) for assessments was drawn up and scientifically evaluated. This article discusses the findings and applicability of the GPS as the basis for a nationwide standardized procedure in Germany as required by the Second Act to Strengthen Long-Term Care (PSG II) under Vol. XI Para. 18 (6) of the German Social Welfare Code. Method: The consortium project comprised four project phases: 1. Qualitative and quantitative situation analysis of the procedures for ascertaining rehabilitative needs in care assessments carried out by the MDK; 2. Development of a Good Practice Standard (GPS) in a structured, consensus-based procedure; 3. Scientific evaluation of the validity, reliability and practicability of the assessment procedure according to the GPS in the MDK's operational practice; 4. Survey of long-term care insurance funds with respect to the appropriateness of the rehabilitation recommendations drawn up by care assessors in line with the GPS for providing a qualified recommendation for the applicant. The evaluation carried out in the third project phase was subject to methodological limitations that may have given rise to distortions in the findings. Findings: On the basis of the situation analysis, 7 major thematic areas were identified in which improvements were implemented by applying the GPS. For the evaluation of the GPS, a total of 3 247 applicants were assessed in line with the GPS; in 6.3% of the applicants, an indication for medical rehabilitation was determined. The GPS procedure showed a high degree of reliability and practicability, but the values for the validity of the assessment procedure were highly unsatisfactory. The degree of acceptance by the long-term care insurance funds with respect to the recommendations for rehabilitation following the GPS procedure was high. Conclusion: The application of a general standard across all MDKs shows marked improvements in the quality of the assessment procedure and leads more frequently to the ascertainment of an indication for medical rehabilitation. The methodological problems and the unsatisfactory findings with respect to the validity of the assessors' decisions require further scientific scrutiny. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Guidelines for Neurotoxicity Risk Assessment

    EPA Pesticide Factsheets

    These Guidelines set forth principles and procedures to guide EPA scientists in evaluating environmental contaminants that may pose neurotoxic risks, and inform Agency decision makers and the public about these procedures.

  19. Clinical skills temporal degradation assessment in undergraduate medical education.

    PubMed

    Fisher, Joseph; Viscusi, Rebecca; Ratesic, Adam; Johnstone, Cameron; Kelley, Ross; Tegethoff, Angela M; Bates, Jessica; Situ-Lacasse, Elaine H; Adamas-Rappaport, William J; Amini, Richard

    2018-01-01

    Medical students' ability to learn clinical procedures and competently apply these skills is an essential component of medical education. Complex skills with limited opportunity for practice have been shown to degrade without continued refresher training. To our knowledge there is no evidence that objectively evaluates temporal degradation of clinical skills in undergraduate medical education. The purpose of this study was to evaluate temporal retention of clinical skills among third year medical students. This was a cross-sectional study conducted at four separate time intervals in the cadaver laboratory at a public medical school. Forty-five novice third year medical students were evaluated for retention of skills in the following three procedures: pigtail thoracostomy, femoral line placement, and endotracheal intubation. Prior to the start of third-year medical clerkships, medical students participated in a two-hour didactic session designed to teach clinically relevant materials including the procedures. Prior to the start of their respective surgery clerkships, students were asked to perform the same three procedures and were evaluated by trained emergency medicine and surgery faculty for retention rates, using three validated checklists. Students were then reassessed at six week intervals in four separate groups based on the start date of their respective surgical clerkships. We compared the evaluation results between students tested one week after training and those tested at three later dates for statistically significant differences in score distribution using a one-tailed Wilcoxon Mann-Whitney U-test for non-parametric rank-sum analysis. Retention rates were shown to have a statistically significant decline between six and 12 weeks for all three procedural skills. In the instruction of medical students, skill degradation should be considered when teaching complex technical skills. Based on the statistically significant decline in procedural skills noted in our investigation, instructors should consider administering a refresher course between six and twelve weeks from initial training.

  20. Improved staff procedure skills lead to improved managment skills: an observational study in an educational setting.

    PubMed

    Rüter, Anders; Vikstrom, Tore

    2009-01-01

    Good staff procedure skills in a management group during incidents and disasters are believed to be a prerequisite for good management of the situation. However, this has not been demonstrated scientifically. Templates for evaluation results from performance indicators during simulation exercises have previously been tested. The aim of this study was to demonstrate the possibility that these indicators can be used as a tool for studying the relationship between good management skills and good staff procedure skills. Good and structured work (staff procedure skills) in a hospital management group during simulation exercises in disaster medicine is related to good and timely decisions (good management skills). Results from 29 consecutive simulation exercises in which staff procedure skills and management skills were evaluated using quantitative measurements were included. The statistical analysis method used was simple linear regression with staff procedure skills as the response variable and management skills as the predictor variable. An overall significant relationship was identified between staff procedure skills and management skills (p(2)0.05). This study suggests that there is a relationship between staff procedure skills and management skills in the educational setting used. Future studies are needed to demonstrate if this also can be observed during actual incidents.

  1. Simplification and Transformation of ASTM F1292 Measurement Procedure for Fall Accident Injury Criteria

    PubMed Central

    KATO, Maki; SHIMODAIRA, Yoshie; SATO, Takeshi; IIDA, Hiromi

    2014-01-01

    Abstract: Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment. PMID:25088989

  2. Simplification and transformation of ASTM F1292 measurement procedure for fall accident injury criteria.

    PubMed

    Kato, Maki; Shimodaira, Yoshie; Sato, Takeshi; Iida, Hiromi

    2014-01-01

    Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment.

  3. Effectiveness of percutaneous vertebroplasty in patients with multiple myeloma having vertebral pain

    PubMed Central

    Nas, Ömer Fatih; İnecikli, Mehmet Fatih; Hacıkurt, Kadir; Büyükkaya, Ramazan; Özkaya, Güven; Özkalemkaş, Fahir; Ali, Rıdvan; Erdoğan, Cüneyt; Hakyemez, Bahattin

    2016-01-01

    PURPOSE We aimed to assess the effectiveness, benefits, and reliability of percutaneous vertebroplasty (PV) in patients with vertebral involvement of multiple myeloma. METHODS PV procedures performed on 166 vertebrae of 41 patients with multiple myeloma were retrospectively evaluated. Most of our patients were using level 3 (moderate to severe pain) analgesics. Magnetic resonance imaging was performed before the procedure to assess vertebral involvement of multiple myeloma. The following variables were evaluated: affected vertebral levels, loss of vertebral body height, polymethylmethacrylate (PMMA) cement amount applied to the vertebral body during PV, PMMA cement leakages, and pain before and after PV as assessed by a visual analogue scale (VAS). RESULTS Median VAS scores of patients decreased from 9 one day before PV, to 6 one day after the procedure, to 3 one week after the procedure, and eventually to 1 three months after the procedure (P < 0.001). During the PV procedure, cement leakage was observed at 68 vertebral levels (41%). The median value of PMMA applied to the vertebral body was 6 mL. CONCLUSION Being a minimally invasive and easily performed procedure with low complication rates, PV should be preferred for serious back pain of multiple myeloma patients. PMID:26912107

  4. Could conscious sedation with midazolam for dental procedures be an alternative to general anesthesia?

    PubMed

    Silay, E; Candirli, C; Taskesen, F; Coskuner, I; Ceyhanli, K T; Yildiz, H

    2013-01-01

    The aim of our study was to evaluate the likelihood that conscious sedation (CS) with intravenous midazolam could become an alternative modality to general anesthesia (GA) for dental procedures. In our study, 58 and 47 American Society of Anesthesiologists (ASA)-1 pediatric patients, aged 2-12 (mean 6) years, underwent dental procedures and minor oral surgical procedures under GA and CS with intravenous midazolam, respectively. The two groups were evaluated in terms of vital signs, duration of the treatment procedure, patient behavior, and the treatment comfort experienced by the physicians. The oxygen saturation level was significantly lower (GA: 99.0 ± 0.30, CS: 98.4 ± 1.02; P < 0.001) and the duration of the treatment procedure was significantly shorter (P < 0.001) in the sedation group compared with the GA group. The physicians encountered various difficulties during implementation of the treatment strategy in cases where they used CS. Minor oral surgical procedures and tooth extraction processes requiring no saline irrigation, however, could be performed successfully under CS. In cases requiring multiple dental management issues, the sedation method was not found to be a useful alternative to GA.

  5. An evaluation of periodontal assessment procedures among Indiana dental hygienists.

    PubMed

    Stephan, Christine A

    2014-01-01

    Using a descriptive correlational design, this study surveyed periodontal assessment procedures currently performed by Indiana dental hygienists in general dentistry practices to reveal if deficiencies in assessment exist. Members (n = 354) of the Indiana Dental Hygienists' Association (IDHA) were invited to participate in the survey. A 22 multiple choice question survey, using Likert scales for responses, was open to participants for three weeks. Descriptive and non-parametric inferential statistics analyzed questions related to demographics and assessment procedures practiced. In addition, an evaluation of the awareness of periodontal assessment procedures recommended by the American Academy of Periodontology (AAP) was examined. Of the 354 Indiana dental hygienists surveyed, a 31.9% response rate was achieved. Participants were asked to identify the recommended AAP periodontal assessment procedures they perform. The majority of respondents indicated either frequently or always performing the listed assessment procedures. Additionally, significant relationships were found between demographic factors and participants' awareness and performance of recommended AAP assessment procedures. While information gathered from this study is valuable to the body of literature regarding periodontal disease assessment, continued research with larger survey studies should be conducted to obtain a more accurate national representation of what is being practiced by dental hygienists.

  6. Development and validation of a screening procedure to identify speech-language delay in toddlers with cleft palate.

    PubMed

    Jørgensen, Line Dahl; Willadsen, Elisabeth

    2017-01-01

    The purpose of this study was to develop and validate a clinically useful speech-language screening procedure for young children with cleft palate ± cleft lip (CP) to identify those in need of speech-language intervention. Twenty-two children with CP were assigned to a +/- need for intervention conditions based on assessment of consonant inventory using a real-time listening procedure in combination with parent-reported expressive vocabulary. These measures allowed evaluation of early speech-language skills found to correlate significantly with later speech-language performance in longitudinal studies of children with CP. The external validity of this screening procedure was evaluated by comparing the +/- need for intervention assignment determined by the screening procedure to experienced speech-language pathologist (SLP)s' clinical judgement of whether or not a child needed early intervention. The results of real-time listening assessment showed good-excellent inter-rater agreement on different consonant inventory measures. Furthermore, there was almost perfect agreement between the children selected for intervention with the screening procedure and the clinical judgement of experienced SLPs indicate that the screening procedure is a valid way of identifying children with CP who need early intervention.

  7. Laboratory evaluation of detectors of explosives' effluents

    DOT National Transportation Integrated Search

    1972-11-30

    This document contains the classification, technical description and laboratory evaluation of five commercial detectors for explosives' effluents. It includes an outline of operating principles, test and evaluation procedures. The evaluation is based...

  8. Sedation with intranasal midazolam of Angolan children undergoing invasive procedures.

    PubMed

    Kawanda, Lumana; Capobianco, Ivan; Starc, Meta; Felipe, Daniel; Zanon, Davide; Barbi, Egidio; Munkela, Nadine; Rodrigues, Verónica; Malundo, Lúis; Not, Tarcisio

    2012-07-01

    Ambulatory surgery is a daily requirement in poor countries, and limited means and insufficient trained staff lead to the lack of attention to the patient's pain. Midazolam is a rapid-onset, short-acting benzodiazepine which is used safely to reduce pain in children. We evaluated the practicability of intranasal midazolam sedation in a suburban hospital in Luanda (Angola), during the surgical procedures. Intranasal midazolam solution was administered at a dose of 0.5 mg/kg. Using the Ramsay's reactivity score, we gave a score to four different types of children's behaviour: moaning, shouting, crying and struggling, and the surgeon evaluated the ease of completing the surgical procedure using scores from 0 (very easy) to 3 (managing with difficulty). Eighty children (median age, 3 years) were recruited, and 140 surgical procedures were performed. Fifty-two children were treated with midazolam during 85 procedures, and 28 children were not treated during 55 procedures. We found a significant difference between the two groups on the shouting, crying and struggling parameters (p < 0.001). The mean score of the ease of completing the procedures was significantly different among the two groups (p < 0.0001). These results provide a model of procedural sedation in ambulatory surgical procedures in poor countries, thus abolishing pain and making the surgeon's job easier. © 2012 The Author(s)/Acta Paediatrica © 2012 Foundation Acta Paediatrica.

  9. Renal access in PNL under sonographic guidance: Do we really need to insert an open end ureteral catheter in dilated renal systems? A prospective randomized study.

    PubMed

    Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal

    2017-10-03

    To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.

  10. Evaluating and Comparing Interventions Designed to Enhance Math Fact Accuracy and Fluency: Cover, Copy, and Compare versus Taped Problems

    ERIC Educational Resources Information Center

    Poncy, Brian C.; Skinner, Christopher H.; Jaspers, Kathryn E.

    2007-01-01

    An adapted alternating treatments design was used to evaluate and compare the effects of two procedures designed to enhance math fact accuracy and fluency in an elementary student with low cognitive functioning. Results showed that although the cover, copy, compare (CCC) and the taped problems (TP) procedures both increased the student's math fact…

  11. Common Core Curriculum for Vocational Education. Category G: Evaluation and Research. G-3: Introduction to Research Procedures in Vocational Education.

    ERIC Educational Resources Information Center

    Moshier, Kenneth

    This module providing an introduction to research procedures is one of a set of five on evaluation and research and is part of a larger series of thirty-four modules constituting a core curriculum for use in the professional preparation of vocational educators in the areas of agricultural, business, home economics, and industrial education.…

  12. Selection, Evaluation, and Modification of a Standard Operating Procedure as a Mechanism for Introducing an Undergraduate Student to Chemical Research: A Case Study

    ERIC Educational Resources Information Center

    Claycomb, Gregory D.; Venable, Frances A.

    2015-01-01

    In an effort to broaden the selection of research opportunities available to a student registered in a one-semester, upper-level independent study course at a primarily undergraduate institution (PUI), a highly motivated student was asked to select, evaluate, and modify a standard operating procedure (SOP). The student gained valuable experience…

  13. Pre-Speech Assessment Scale: A Rating Scale for the Measurement of Pre-Speech Behaviors from Birth through Two Years. Revised Edition.

    ERIC Educational Resources Information Center

    Morris, Suzanne Evans

    The manual contains the Pre-Speech Assessment Scale (PSAS) intended for use with cerebral palsied and other handicapped children to evaluate behaviors at the birth through 2-year age level. Introductory information covers the development of the PSAS, concepts underlying the PSAS, evaluation procedures, scoring the PSAS, and graphing procedures.…

  14. Comparison of mapping algorithms used in high-throughput sequencing: application to Ion Torrent data

    PubMed Central

    2014-01-01

    Background The rapid evolution in high-throughput sequencing (HTS) technologies has opened up new perspectives in several research fields and led to the production of large volumes of sequence data. A fundamental step in HTS data analysis is the mapping of reads onto reference sequences. Choosing a suitable mapper for a given technology and a given application is a subtle task because of the difficulty of evaluating mapping algorithms. Results In this paper, we present a benchmark procedure to compare mapping algorithms used in HTS using both real and simulated datasets and considering four evaluation criteria: computational resource and time requirements, robustness of mapping, ability to report positions for reads in repetitive regions, and ability to retrieve true genetic variation positions. To measure robustness, we introduced a new definition for a correctly mapped read taking into account not only the expected start position of the read but also the end position and the number of indels and substitutions. We developed CuReSim, a new read simulator, that is able to generate customized benchmark data for any kind of HTS technology by adjusting parameters to the error types. CuReSim and CuReSimEval, a tool to evaluate the mapping quality of the CuReSim simulated reads, are freely available. We applied our benchmark procedure to evaluate 14 mappers in the context of whole genome sequencing of small genomes with Ion Torrent data for which such a comparison has not yet been established. Conclusions A benchmark procedure to compare HTS data mappers is introduced with a new definition for the mapping correctness as well as tools to generate simulated reads and evaluate mapping quality. The application of this procedure to Ion Torrent data from the whole genome sequencing of small genomes has allowed us to validate our benchmark procedure and demonstrate that it is helpful for selecting a mapper based on the intended application, questions to be addressed, and the technology used. This benchmark procedure can be used to evaluate existing or in-development mappers as well as to optimize parameters of a chosen mapper for any application and any sequencing platform. PMID:24708189

  15. Scientific evaluation and pricing of medical devices and associated procedures in France.

    PubMed

    Gilard, Martine; Debroucker, Frederique; Dubray, Claude; Allioux, Yves; Aper, Eliane; Barat-Leonhardt, Valérie; Brami, Michèle; Carbonneil, Cédric; Chartier-Kastler, Emmanuel; Coqueblin, Claire; Fare, Sandrine; Giri, Isabelle; Goehrs, Jean-Marie; Levesque, Karine; Maugendre, Philippe; Parquin, François; Sales, Jean-Patrick; Szwarcensztein, Karine

    2013-01-01

    Medical devices are many and various, ranging from tongue spatulas to implantable or invasive devices and imaging machines; their lifetimes are short, between 18 months and 5 years, due to incessant incremental innovation; and they are operator-dependent: in general, the clinical user performs a fitting procedure (hip implant or pacemaker), a therapeutic procedure using a non-implantable invasive device (arrhythmic site ablation probe, angioplasty balloon, extension spondyloplasty system, etc.) or follow-up of an active implanted device (long-term follow-up of an implanted cardiac defibrillator or of a deep brain stimulator in Parkinson's patients). A round-table held during the XXVIII(th) Giens Workshops meeting focused on the methodology of scientific evaluation of medical devices and the associated procedures with a view to their pricing and financing by the French National Health Insurance system. The working hypothesis was that the available data-set was sufficient for and compatible with scientific evaluation with clinical benefit. Post-registration studies, although contributing to the continuity of assessment, were not dealt with. Moreover, the focus was restricted to devices used in health establishments, where the association between devices and technical medical procedures is optimally representative. An update of the multiple regulatory protocols governing medical devices and procedures is provided. Issues more specifically related to procedures as such, to non-implantable devices and to innovative devices are then dealt with, and the proposals and discussion points raised at the round-table for each of these three areas are presented. © 2013 Société Française de Pharmacologie et de Thérapeutique.

  16. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors

    PubMed Central

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-01

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors’ radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors’ application, and as such will promote the development of Chinese satellite data. PMID:28117745

  17. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors.

    PubMed

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-22

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors' radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors' application, and as such will promote the development of Chinese satellite data.

  18. The evaluation of the abuse liability of drugs.

    PubMed

    Johanson, C E

    1990-01-01

    In order to place appropriate restrictions upon the availability of certain therapeutic agents to limit their abuse, it is important to assess abuse liability, an important aspect of drug safety evaluation. However, the negative consequences of restriction must also be considered. Drugs most likely to be tested are psychoactive compounds with therapeutic indications similar to known drugs of abuse. Methods include assays of pharmacological profile, drug discrimination procedures, self-administration procedures, and measures of drug-induced toxicity including evaluations of tolerance and physical dependence. Furthermore, the evaluation of toxicity using behavioural end-points is an important component of the assessment, and it is generally believed that the most valid procedure in this evaluation is the measurement of drug self-administration. However, even this method rarely predicts the extent of abuse of a specific drug. Although methods are available which appear to measure relative abuse liability, these procedures are not validated for all drug classes. Thus, additional strategies, including abuse liability studies in humans, modelled after those used with animals, must be used in order to make a more informed prediction. Although there is pressure to place restrictions on new drugs at the time of marketing, in light of the difficulty of predicting relative abuse potential, a better strategy might be to market a drug without restrictions, but require postmarketing surveillance in order to obtain more accurate information on which to base a final decision.

  19. Nondestructive evaluation for sorting red maple logs

    Treesearch

    Xiping Wang; Robert J. Ross; David W. Green; Karl Englund; Michael Wolcott

    2000-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  20. Critical Emergency Medicine Procedural Skills: A Comparative Study of Methods for Teaching and Assessment.

    ERIC Educational Resources Information Center

    Chapman, Dane M.; And Others

    Three critical procedural skills in emergency medicine were evaluated using three assessment modalities--written, computer, and animal model. The effects of computer practice and previous procedure experience on skill competence were also examined in an experimental sequential assessment design. Subjects were six medical students, six residents,…

  1. Decreasing Inappropriate Vocalizations Using Classwide Group Contingencies and Color Wheel Procedures: A Component Analysis

    ERIC Educational Resources Information Center

    Kirk, Emily R.; Becker, Jennifer A.; Skinner, Christopher H., Fearrington, Jamie Yarbr; McCane-Bowling, Sara J.; Amburn, Christie; Luna, Elisa; Greear, Corinne

    2010-01-01

    Teacher referrals for consultation resulted in two independent teams collecting evidence that allowed for a treatment component evaluation of color wheel (CW) procedures and/or interdependent group-oriented reward (IGOR) procedures on inappropriate vocalizations in one third- and one first-grade classroom. Both studies involved the application of…

  2. Device-Task Fidelity and Transfer of Training: Aircraft Cockpit Procedures Training.

    ERIC Educational Resources Information Center

    Prophet, Wallace W.; Boyd, H. Alton

    An evaluation was made of the training effectiveness of two cockpit procedures training devices, differing greatly in physical fidelity and cost, for use on the ground for a twin-engine, turboprop, fixed-wing aircraft. One group of students received training in cockpit procedures in a relatively expensive, sophisticated, computerized trainer,…

  3. 78 FR 72091 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-02

    ... in Sec. 211.100(b); and standard operating procedures should be reviewed and revised or supplementary... manufacturers to include a procedure in their Plan for notifying the Center for Drug Evaluation and Research... drug products will be manufactured under altered procedures, which products will have manufacturing...

  4. Two Procedures for Relaxation as Self-Control in the Treatment of Communication Apprehension

    ERIC Educational Resources Information Center

    Deffenbacher, Jerry L.; Payne, Dennis M.

    1977-01-01

    An in vivo procedure for relaxation as self-control and a procedure for self-control modification of desensitization were compared to a no-treatment control. Results showed modified desensitization, compared to the control, significantly decreased communication anxiety and fear of negative evaluation and significantly increased assertiveness.…

  5. The Implications of Bank-Issued Check Surveys for Evaluators: A Case Study

    ERIC Educational Resources Information Center

    Blair, Jason; Taylor, Ted K.; Johnson-Shelton, Deborah

    2007-01-01

    This article describes an innovative data collection procedure. A subsample (n = 164) of a longitudinal research project was assessed using a bank-issued check survey procedure (a removable bank check on which response fields were printed). Using the new procedure, parents returned their surveys simply by depositing or cashing their incentive…

  6. Effect of lower limb Sofield procedure on ambulation in osteogenesis imperfecta.

    PubMed

    Khoshhal, K I; Ellis, R D

    2001-01-01

    Ambulation status was evaluated in 34 patients pre- and post-Sofield procedure in patients with osteogenesis imperfecta. Three percent had improved ambulation, 42.4% remained the same and 54.6% were worse. Only 41.2% were ambulating postoperatively compared to 73.5% preoperatively. The Sofield procedure did not improve ambulation status.

  7. Improving Conceptual and Procedural Knowledge: The Impact of Instructional Content within a Mathematics Lesson

    ERIC Educational Resources Information Center

    Rittle-Johnson, Bethany; Fyfe, Emily R.; Loehr, Abbey M.

    2016-01-01

    Background: Students, parents, teachers, and theorists often advocate for direct instruction on both concepts and procedures, but some theorists suggest that including instruction on procedures in combination with concepts may limit learning opportunities and student understanding. Aims: This study evaluated the effect of instruction on a math…

  8. Adjustment in University Students Admitted by High School Recommendations as Compared with Their Classmates

    ERIC Educational Resources Information Center

    Cheung, Chau-Kiu; Lok, David Ping-Pui; Chan, David Kin-keung

    2005-01-01

    Adjustment in university students admitted based on their high school counselors' or advisors' recommendation is an issue for revealing the appropriateness and fairness of the nontraditional admissions procedure. The newly-issued admissions procedure in Hong Kong has not been subject to empirical investigation. To evaluate the procedure, the…

  9. Estimating acreage by double sampling using LANDSAT data

    NASA Technical Reports Server (NTRS)

    Pont, F.; Horwitz, H.; Kauth, R. (Principal Investigator)

    1982-01-01

    Double sampling techniques employing LANDSAT data for estimating the acreage of corn and soybeans was investigated and evaluated. The evaluation was based on estimated costs and correlations between two existing procedures having differing cost/variance characteristics, and included consideration of their individual merits when coupled with a fictional 'perfect' procedure of zero bias and variance. Two features of the analysis are: (1) the simultaneous estimation of two or more crops; and (2) the imposition of linear cost constraints among two or more types of resource. A reasonably realistic operational scenario was postulated. The costs were estimated from current experience with the measurement procedures involved, and the correlations were estimated from a set of 39 LACIE-type sample segments located in the U.S. Corn Belt. For a fixed variance of the estimate, double sampling with the two existing LANDSAT measurement procedures can result in a 25% or 50% cost reduction. Double sampling which included the fictional perfect procedure results in a more cost effective combination when it is used with the lower cost/higher variance representative of the existing procedures.

  10. Evaluation of the effectiveness and efficiency of two stimulus prompt strategies with severely handicapped students.

    PubMed Central

    Steege, M W; Wacker, D P; McMahon, C M

    1987-01-01

    In this study we compared the effectiveness and efficiency of two treatment packages that used stimulus prompt sequences and task analyses for teaching community living skills to severely handicapped students. Four severely and multiply handicapped students were trained to perform four tasks: (a) making toast, (b) making popcorn, (c) operating a clothes dryer, and (d) operating a washing machine. Following baseline, each student was exposed to two types of training procedures, each involving a task analysis of the target behavior. Training Procedure 1 (Traditional) utilized a least-to-most restrictive prompt sequence. Training Procedure 2 (Prescriptive) utilized ongoing behavioral assessment data to identify discriminative stimuli. The assessment data were used to prescribe instructional prompts across successive training trials. Performance on the tasks was evaluated within a combination multiple baseline (across subjects) and probe (across tasks) design. Training conditions were counterbalanced across subjects and tasks. Results indicated that both training procedures were equally effective in increasing independent task acquisition for subjects on all tasks; however, the prescriptive procedure was the more efficient procedure. PMID:3667479

  11. Safety of propofol sedation for pediatric outpatient procedures.

    PubMed

    Larsen, Reagan; Galloway, David; Wadera, Sheetal; Kjar, Dean; Hardy, David; Mirkes, Curtis; Wick, Lori; Pohl, John F

    2009-10-01

    Propofol sedation is used more frequently in pediatric procedures because of its ability to provide varying sedation levels. The authors evaluated all outpatient pediatric procedures using propofol sedation over a 6-year period. All sedation was provided by pediatric intensivists at a single institution. In all, 4716 procedures were recorded during the study period; 15% of procedures were associated with minor complications, whereas only 0.1% of procedures were associated with major complications. Significantly more major complications associated with propofol occurred during bronchoscopy (P = .001). Propofol administered by a pediatric intensivist is a safe sedation technique in the pediatric outpatient setting.

  12. 30 CFR 19.3 - Application procedures and requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.3 Application procedures and requirements... Certification Center, 765 Technology Drive, Triadelphia, WV 26059, together with the required drawings, one...

  13. 30 CFR 22.4 - Application procedures and requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.4 Application procedures and requirements. (a) Before MSHA will undertake an active investigation leading to approval of any methane...

  14. 30 CFR 19.3 - Application procedures and requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.3 Application procedures and requirements... Certification Center, 765 Technology Drive, Triadelphia, WV 26059, together with the required drawings, one...

  15. 30 CFR 19.3 - Application procedures and requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.3 Application procedures and requirements... Certification Center, 765 Technology Drive, Triadelphia, WV 26059, together with the required drawings, one...

  16. 30 CFR 19.3 - Application procedures and requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.3 Application procedures and requirements... Certification Center, 765 Technology Drive, Triadelphia, WV 26059, together with the required drawings, one...

  17. 30 CFR 19.3 - Application procedures and requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.3 Application procedures and requirements... Certification Center, 765 Technology Drive, Triadelphia, WV 26059, together with the required drawings, one...

  18. A procedure for evaluating environmental impact

    USGS Publications Warehouse

    Leopold, Luna Bergere; Clarke, Frank Eldridge; Hanshaw, Bruce B.; Balsley, James R.

    1971-01-01

    The procedure does not limit the development of detail in any specific aspect of the environment; a separate expanded matrix for any environmental aspect can easily be developed within the framework provided.

  19. [Scientific monitoring of the visitation procedure in inpatient rehabilitation centres of the German statutory pension insurance fund--the "Visit II" Project].

    PubMed

    Neuderth, S; Saupe-Heide, M; Brückner, U; Gross, B; Wenderoth, N; Vogel, H

    2012-06-01

    Visitation procedures are an established method of external quality assurance. They have been conducted for many years in the German statutory pension insurance's medical rehabilitation centres and have continuously been refined and standardized. The overall goal of the visitation procedure implemented by the German statutory pension fund is to ensure compliance with defined quality standards as well as information exchange and counselling of rehabilitation centres. In the context of advancing the visitation procedure in the German statutory pension funds' medical rehabilitation centres, the "Visit II" Project was initiated to evaluate the perspectives and expectations of the various professional groups involved in the visitations and to modify the materials used during visitations (documentation form and manual). Evaluation data from the rehabilitation centres visited in 2008 were gathered using both written surveys (utilization analysis) and telephone-based interviews with administration managers and chief physicians. The utilization analysis procedure was evaluated with regard to its methodological quality. In addition, the pension insurance physicians in charge of patient allocation during socio-medical assessment were surveyed with regard to potential needs for revision of the visitation procedure. Data collection was complemented by expert panels with auditors. Interviews with users as part of the formative evaluation of the visitation procedure showed positive results regarding acceptance and applicability of the visitations as well as of the utilization analysis procedures. Various suggestions were made with regard to modification and revision of the visitation materials, that could be implemented in many cases. Documentation forms were supplemented by current scientifically-based topics in rehabilitation (e. g., vocationally oriented measures), whereas items with minor relevance were skipped. The manual (for somatic indications) was thoroughly revised. The transparent presentation of visitation processes and visitation criteria has proven to be a useful basis for strengthening the cooperation between the statutory pension insurance funds and the rehabilitation centres. Moreover, it is a helpful tool for the systematic and continuous advancement of this complex method by including all parties involved. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Quality control of colonoscopy procedures: a prospective validated method for the evaluation of professional practices applicable to all endoscopic units.

    PubMed

    Coriat, R; Pommaret, E; Chryssostalis, A; Viennot, S; Gaudric, M; Brezault, C; Lamarque, D; Roche, H; Verdier, D; Parlier, D; Prat, F; Chaussade, S

    2009-02-01

    To produce valid information, an evaluation of professional practices has to assess the quality of all practices before, during and after the procedure under study. Several auditing techniques have been proposed for colonoscopy. The purpose of this work is to describe a straightforward original validated method for the prospective evaluation of professional practices in the field of colonoscopy applicable in all endoscopy units without increasing the staff work load. Pertinent quality-control criteria (14 items) were identified by the endoscopists at the Cochin Hospital and were compatible with: findings in the available literature; guidelines proposed by the Superior Health Authority; and application in any endoscopy unit. Prospective routine data were collected and the methodology validated by evaluating 50 colonoscopies every quarter for one year. The relevance of the criteria was assessed using data collected during four separate periods. The standard checklist was complete for 57% of the colonoscopy procedures. The colonoscopy procedure was appropriate according to national guidelines in 94% of cases. These observations were particularly noteworthy: the quality of the colonic preparation was insufficient for 9% of the procedures; complete colonoscopy was achieved for 93% of patients; and 0.38 adenomas and 0.045 carcinomas were identified per colonoscopy. This simple and reproducible method can be used for valid quality-control audits in all endoscopy units. In France, unit-wide application of this method enables endoscopists to validate 100 of the 250 points required for continuous medical training. This is a quality-control tool that can be applied annually, using a random month to evaluate any changes in routine practices.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful;more » in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.« less

  2. Balloon dilation of the eustachian tube in a cadaver model: technical considerations, learning curve, and potential barriers.

    PubMed

    McCoul, Edward D; Singh, Ameet; Anand, Vijay K; Tabaee, Abtin

    2012-04-01

    The surgical management options for eustachian tube dysfunction have historically been limited. The goal of the current study was to evaluate the technical considerations, learning curve, and potential barriers for balloon dilation of the eustachian tube (BDET) as an alternative treatment modality. Prospective preclinical trial of BDET in a cadaver model. A novel balloon catheter device was used for eustachian tube dilation. Twenty-four BDET procedures were performed by three independent rhinologists with no prior experience with the procedure (eight procedures per surgeon). The duration and number of attempts of the individual steps and overall procedure were recorded. Endoscopic examination of the eustachian tube was performed after each procedure, and the surgeon was asked to rate the subjective difficulty on a five-point scale. Successful completion of the procedure occurred in each case. The overall mean duration of the procedure was 284 seconds, and a mean number of 1.15 attempts were necessary to perform the individual steps. The mean subjective procedure difficulty was noted as somewhat easy. Statistically shorter duration and subjectively easier procedure were noted in the second compared to the first half of the series, indicating a favorable learning curve. Linear fissuring within the eustachian tube lumen without submucosal disruption (nine procedures, 37%) and with submucosal disruption (five procedures, 21%) were noted. The significance of these physical findings is unclear. Preclinical testing of BDET is associated with favorable duration, learning curve, and overall ease of completion. Clinical trials are necessary to evaluate safety and efficacy. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  3. Medical tongue piercing – development and evaluation of a surgical protocol and the perception of procedural discomfort of the participants

    PubMed Central

    2014-01-01

    Background A system providing disabled persons with control of various assistive devices with the tongue has been developed at Aalborg University in Denmark. The system requires an activation unit attached to the tongue with a small piercing. The aim of this study was to establish and evaluate a safe and tolerable procedure for medical tongue piercing and to evaluate the expected and perceived procedural discomfort. Methods Four tetraplegic subjects volunteered for the study. A surgical protocol for a safe insertion of a tongue barbell piercing was presented using sterilized instruments and piercing parts. Moreover, post-procedural observations of participant complications such as bleeding, edema, and infection were recorded. Finally, procedural discomforts were monitored by VAS scores of pain, changes in taste and speech as well as problems related to hitting the teeth. Results The piercings were all successfully inserted in less than 5 min and the pain level was moderate compared with oral injections. No bleeding, infection, embedding of the piercing, or tooth/gingival injuries were encountered; a moderate edema was found in one case without affecting the speech. In two cases the piercing rod later had to be replaced by a shorter rod, because participants complained that the rod hit their teeth. The replacements prevented further problems. Moreover, loosening of balls was encountered, which could be prevented with the addition of dental glue. No cases of swallowing or aspiration of the piercing parts were recorded. Conclusions The procedure proved simple, fast, and safe for insertion of tongue piercings for tetraplegic subjects in a clinical setting. The procedure represented several precautions in order to avoid risks in these susceptible participants with possible co-morbidity. No serious complications were encountered, and the procedure was found tolerable to the participants. The procedure may be used in future studies with tongue piercings being a prerequisite for similar systems, and this may include insertion in an out-patient setting. PMID:24684776

  4. Evaluation of Oral and Maxillofacial Surgery Residents' Operative Skills: Feasibility and Engagement Study Using SIMPL Software for a Mobile Phone.

    PubMed

    Kaban, Leonard B; Cappetta, Alyssa; George, Brian C; Lahey, Edward T; Bohnen, Jordan D; Troulis, Maria J

    2017-10-01

    There are no universally accepted tools to evaluate operative skills of surgical residents in a timely fashion. The purpose of this study was to determine the feasibility of using a smartphone application, SIMPL (System for Improving and Measuring Procedural Learning), developed by a multi-institutional research collaborative, to achieve a high rate of timely operative evaluations and resident communication and to collect performance data. The authors hypothesized that these goals would be achieved because the process is convenient and efficient. This was a prospective feasibility and engagement study using SIMPL to evaluate residents' operative skills. SIMPL requires the attending surgeon to answer 3 multiple-choice questions: 1) What level of help (Zwisch Scale) was required by the trainee? 2) What was the level of performance? 3) How complex was the case? The evaluator also can dictate a narrative. The sample was composed of 3 faculty members and 3 volunteer senior residents. Predictor variables were the surgeons, trainees, and procedures performed. Outcome variables included number and percentage of procedures performed by faculty-and-resident pairs assessed, time required to complete assessments, time lapsed to submission, percentage of assessments with narratives, and residents' response rates. From March through June 2016, 151 procedures were performed in the operating room by the faculty-and-resident teams. There were 107 assessments submitted (71%). Resident response (self-assessment) to faculty evaluations was 81%. Recorded time to complete assessments (n = 75 of 107) was shorter than 2 minutes. The time lapsed to submission was shorter than 72 hours (100%). Dictations were submitted for 35 evaluations (33%). Data for the type of help, performance, and complexity of cases were collected for each resident. SIMPL facilitates timely intraoperative evaluations of surgical skills, engagement by faculty and residents, and collection of detailed procedural data. Additional prospective trials to assess this tool further are planned. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Performance evaluation of Olympic weightlifters.

    PubMed

    Garhammer, J

    1979-01-01

    The comparison of weights lifted by athletes in different bodyweight categories is a continuing problem for the sport of olympic weightlifting. An objective mechanical evaluation procedure was developed using basic ideas from a model proposed by Ranta in 1975. This procedure was based on more realistic assumptions than the original model and considered both vertical and horizontal bar movements. Utilization of data obtained from film of national caliber lifters indicated that the proposed method was workable, and that the evaluative indices ranked lifters in reasonable order relative to other comparative techniques.

  6. An automatic agricultural zone classification procedure for crop inventory satellite images

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Kux, H. J.; Velasco, F. R. D.; Deoliveira, M. O. B.

    1982-01-01

    A classification procedure for assessing crop areal proportion in multispectral scanner image is discussed. The procedure is into four parts: labeling; classification; proportion estimation; and evaluation. The procedure also has the following characteristics: multitemporal classification; the need for a minimum field information; and verification capability between automatic classification and analyst labeling. The processing steps and the main algorithms involved are discussed. An outlook on the future of this technology is also presented.

  7. An evaluation of in vivo desensitization and video modeling to increase compliance with dental procedures in persons with mental retardation.

    PubMed

    Conyers, Carole; Miltenberger, Raymond G; Peterson, Blake; Gubin, Amber; Jurgens, Mandy; Selders, Andrew; Dickinson, Jessica; Barenz, Rebecca

    2004-01-01

    Fear of dental procedures deters many individuals with mental retardation from accepting dental treatment. This study was conducted to assess the effectiveness of two procedures, in vivo desensitization and video modeling, for increasing compliance with dental procedures in participants with severe or profound mental retardation. Desensitization increased compliance for all 5 participants, whereas video modeling increased compliance for only 1 of 3 participants.

  8. Applications of self-control procedures by children: a review.

    PubMed Central

    O'Leary, S G; Dubey, D R

    1979-01-01

    Self-control procedures as used by children to affect their own behavior were reviewed. Particular emphasis was placed on self-instruction, self-determined criteria, self-assessment, and self-reinforcement. Self-punishment, comprehensive programs, and innovative self-control procedures (distraction and restatement of contingencies) were also evaluated. Basic effectiveness, comparisons with similar externally imposed interventions, maintenance, and the augmental value of the procedures were assessed. Important problems for future research were identified. PMID:389917

  9. An Approach to a Comprehensive Test Framework for Analysis and Evaluation of Text Line Segmentation Algorithms

    PubMed Central

    Brodic, Darko; Milivojevic, Dragan R.; Milivojevic, Zoran N.

    2011-01-01

    The paper introduces a testing framework for the evaluation and validation of text line segmentation algorithms. Text line segmentation represents the key action for correct optical character recognition. Many of the tests for the evaluation of text line segmentation algorithms deal with text databases as reference templates. Because of the mismatch, the reliable testing framework is required. Hence, a new approach to a comprehensive experimental framework for the evaluation of text line segmentation algorithms is proposed. It consists of synthetic multi-like text samples and real handwritten text as well. Although the tests are mutually independent, the results are cross-linked. The proposed method can be used for different types of scripts and languages. Furthermore, two different procedures for the evaluation of algorithm efficiency based on the obtained error type classification are proposed. The first is based on the segmentation line error description, while the second one incorporates well-known signal detection theory. Each of them has different capabilities and convenience, but they can be used as supplements to make the evaluation process efficient. Overall the proposed procedure based on the segmentation line error description has some advantages, characterized by five measures that describe measurement procedures. PMID:22164106

  10. An approach to a comprehensive test framework for analysis and evaluation of text line segmentation algorithms.

    PubMed

    Brodic, Darko; Milivojevic, Dragan R; Milivojevic, Zoran N

    2011-01-01

    The paper introduces a testing framework for the evaluation and validation of text line segmentation algorithms. Text line segmentation represents the key action for correct optical character recognition. Many of the tests for the evaluation of text line segmentation algorithms deal with text databases as reference templates. Because of the mismatch, the reliable testing framework is required. Hence, a new approach to a comprehensive experimental framework for the evaluation of text line segmentation algorithms is proposed. It consists of synthetic multi-like text samples and real handwritten text as well. Although the tests are mutually independent, the results are cross-linked. The proposed method can be used for different types of scripts and languages. Furthermore, two different procedures for the evaluation of algorithm efficiency based on the obtained error type classification are proposed. The first is based on the segmentation line error description, while the second one incorporates well-known signal detection theory. Each of them has different capabilities and convenience, but they can be used as supplements to make the evaluation process efficient. Overall the proposed procedure based on the segmentation line error description has some advantages, characterized by five measures that describe measurement procedures.

  11. Development of Tasks and Evaluation of a Prototype Forceps for NOTES

    PubMed Central

    Addis, Matthew; Aguirre, Milton; Haluck, Randy; Matthew, Abraham; Pauli, Eric; Gopal, Jegan

    2012-01-01

    Background and Objectives: Few standardized testing procedures exist for instruments intended for Natural Orifice Translumenal Endoscopic Surgery. These testing procedures are critical for evaluating surgical skills and surgical instruments to ensure sufficient quality. This need is widely recognized by endoscopic surgeons as a major hurdle for the advancement of Natural Orifice Translumenal Endoscopic Surgery. Methods: Beginning with tasks currently used to evaluate laparoscopic surgeons and instruments, new tasks were designed to evaluate endoscopic surgical forceps instruments. Results: Six tasks have been developed from existing tasks, adapted and modified for use with endoscopic instruments, or newly designed to test additional features of endoscopic forceps. The new tasks include the Fuzzy Ball Task, Cup Drop Task, Ring Around Task, Material Pull Task, Simulated Biopsy Task, and the Force Gauge Task. These tasks were then used to evaluate the performance of a new forceps instrument designed at Pennsylvania State University. Conclusions: The need for testing procedures for the advancement of Natural Orifice Translumenal Endoscopic Surgery has been addressed in this work. The developed tasks form a basis for not only testing new forceps instruments, but also for evaluating individual performance of surgical candidates with endoscopic forceps instruments. PMID:22906337

  12. A Procedure for High Resolution Satellite Imagery Quality Assessment

    PubMed Central

    Crespi, Mattia; De Vendictis, Laura

    2009-01-01

    Data products generated from High Resolution Satellite Imagery (HRSI) are routinely evaluated during the so-called in-orbit test period, in order to verify if their quality fits the desired features and, if necessary, to obtain the image correction parameters to be used at the ground processing center. Nevertheless, it is often useful to have tools to evaluate image quality also at the final user level. Image quality is defined by some parameters, such as the radiometric resolution and its accuracy, represented by the noise level, and the geometric resolution and sharpness, described by the Modulation Transfer Function (MTF). This paper proposes a procedure to evaluate these image quality parameters; the procedure was implemented in a suitable software and tested on high resolution imagery acquired by the QuickBird, WorldView-1 and Cartosat-1 satellites. PMID:22412312

  13. Automated generation of influence functions for planar crack problems

    NASA Technical Reports Server (NTRS)

    Sire, Robert A.; Harris, David O.; Eason, Ernest D.

    1989-01-01

    A numerical procedure for the generation of influence functions for Mode I planar problems is described. The resulting influence functions are in a form for convenient evaluation of stress-intensity factors for complex stress distributions. Crack surface displacements are obtained by a least-squares solution of the Williams eigenfunction expansion for displacements in a cracked body. Discrete values of the influence function, evaluated using the crack surface displacements, are curve fit using an assumed functional form. The assumed functional form includes appropriate limit-behavior terms for very deep and very shallow cracks. Continuous representation of the influence function provides a convenient means for evaluating stress-intensity factors for arbitrary stress distributions by numerical integration. The procedure is demonstrated for an edge-cracked strip and a radially cracked disk. Comparisons with available published results demonstrate the accuracy of the procedure.

  14. Health care transition in Germany – standardization of procedures and improvement actions

    PubMed Central

    Pieper, Claudia; Kolankowska, Izabela

    2011-01-01

    Previous studies have assessed an increase in the number of people in need and emphasized the advantages of structured discharge management and health care transition. Therefore, our study evaluated the status quo of transition in a major German city after standardization of procedures and implementation of standard forms. Satisfaction with handling of standard forms and improvement of procedures was evaluated. Additionally, patients who had recently been hospitalized were asked about the hospital discharge process. The results show that the recent efforts of standardization helped to improve interface management for health care workers and patients and showed further improvement options. PMID:21811388

  15. Utility of preclinical drug versus food choice procedures to evaluate candidate medications for methamphetamine use disorder.

    PubMed

    Banks, Matthew L

    2017-04-01

    Substance use disorders are diagnosed as a manifestation of inappropriate behavioral allocation toward abused drugs and away from other behaviors maintained by more adaptive nondrug reinforcers (e.g., money and social relationships). Substance use disorder treatment goals include not only decreasing drug-maintained behavior but also promoting behavioral reallocation toward these socially adaptive alternative reinforcers. Preclinical drug self-administration procedures that offer concurrent access to both drug and nondrug reinforcers provide a translationally relevant dependent measure of behavioral allocation that may be useful for candidate medication evaluation. In contrast to other abused drugs, such as heroin or cocaine, preclinical methamphetamine versus food choice procedures have been a more recent development. We hypothesize that preclinical to clinical translatability would be improved by the evaluation of repeated pharmacological treatment effects on methamphetamine self-administration under a methamphetamine versus food choice procedure. In support of this hypothesis, a literature review suggests strong concordance between preclinical pharmacological treatment effects on methamphetamine versus food choice in nonhuman primates and clinical medication treatment effects on methamphetamine self-administration in human laboratory studies or methamphetamine abuse metrics in clinical trials. In conclusion, this literature suggests preclinical methamphetamine versus food choice procedures may be useful in developing innovative pharmacotherapies for methamphetamine use disorder. © 2016 New York Academy of Sciences.

  16. Utility of preclinical drug versus food choice procedures to evaluate candidate medications for methamphetamine use disorder

    PubMed Central

    Banks, Matthew L.

    2016-01-01

    Substance use disorders are diagnosed as a manifestation of inappropriate behavioral allocation towards abused drugs and away from other behaviors maintained by more adaptive nondrug reinforcers (e.g., work and social relationships). Substance use disorder treatment goals include not only decreasing drug-maintained behavior but also promoting behavioral reallocation toward these socially adaptive alternative reinforcers. Preclinical drug self-administration procedures that offer concurrent access to both drug and nondrug reinforcers provide a translationally relevant dependent measure of behavioral allocation that may be useful for candidate medication evaluation. In contrast to other abused drugs, such as heroin or cocaine, preclinical methamphetamine versus food choice procedures have been a more recent development. We hypothesize that preclinical to clinical translatability would be improved by the evaluation of repeated pharmacological treatment effects on methamphetamine self-administration under a methamphetamine versus food choice procedure. In support of this hypothesis, a literature review suggests strong concordance between preclinical pharmacological treatment effects on methamphetamine versus food choice in nonhuman primates and clinical medication treatment effects on methamphetamine self-administration in human laboratory studies or methamphetamine abuse metrics in clinical trials. In conclusion, this literature suggests preclinical methamphetamine versus food choice procedures may be useful in developing innovative pharmacotherapies for methamphetamine use disorder. PMID:27936284

  17. Proceduralism and its role in economic evaluation and priority setting in health.

    PubMed

    Jan, Stephen

    2014-05-01

    This paper provides a critical overview of Gavin Mooney's proceduralist approach to economic evaluation and priority setting in health. Proceduralism is the notion that the social value attached to alternative courses of action should be determined not only by outcomes, but also processes. Mooney's brand of proceduralism was unique and couched within a broader critique of 'neo-liberal' economics. It operated on a number of levels. At the micro level of the individual program, he pioneered the notion that 'process utility' could be valued and measured within economic evaluation. At a macro level, he developed a framework in which the social objective of equity was defined by procedural justice in which communitarian values were used as the basis for judging how resources should be allocated across the health system. Finally, he applied the notion of procedural justice to further our understanding of the political economy of resource allocation; highlighting how fairness in decision making processes can overcome the sometimes intractable zero-sum resource allocation problem. In summary, his contributions to this field have set the stage for innovative programs of research to help in developing health policies and programs that are both in alignment with community values and implementable. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Improving accountability in vaccine decision-making.

    PubMed

    Timmis, James Kenneth; Black, Steven; Rappuoli, Rino

    2017-11-01

    Healthcare decisions, in particular those affecting entire populations, should be evidence-based and taken by decision-makers sharing broad alignment with affected stakeholders. However, criteria, priorities and procedures for decision-making are sometimes non-transparent, frequently vary considerably across equivalent decision-bodies, do not always consider the broader benefits of new health-measures, and therefore do not necessarily adequately represent the relevant stakeholder-spectrum. Areas covered: To address these issues in the context of the evaluation of new vaccines, we have proposed a first baseline set of core evaluation criteria, primarily selected by members of the vaccine research community, and suggested their implementation in vaccine evaluation procedures. In this communication, we review the consequences and utility of stakeholder-centered core considerations to increase transparency in and accountability of decision-making procedures, in general, and of the benefits gained by their inclusion in Multi-Criteria-Decision-Analysis tools, exemplified by SMART Vaccines, specifically. Expert commentary: To increase effectiveness and comparability of health decision outcomes, decision procedures should be properly standardized across equivalent (national) decision bodies. To this end, including stakeholder-centered criteria in decision procedures would significantly increase their transparency and accountability, support international capacity building to improve health, and reduce societal costs and inequity resulting from suboptimal health decision-making.

  19. Simulation center training as a means to improve resident performance in percutaneous noncontinuous CT-guided fluoroscopic procedures with dose reduction.

    PubMed

    Mendiratta-Lala, Mishal; Williams, Todd R; Mendiratta, Vivek; Ahmed, Hafeez; Bonnett, John W

    2015-04-01

    The purpose of this study was to evaluate the effectiveness of a multifaceted simulation-based resident training for CT-guided fluoroscopic procedures by measuring procedural and technical skills, radiation dose, and procedure times before and after simulation training. A prospective analysis included 40 radiology residents and eight staff radiologists. Residents took an online pretest to assess baseline procedural knowledge. Second-through fourth-year residents' baseline technical skills with a procedural phantom were evaluated. First-through third-year residents then underwent formal didactic and simulation-based procedural and technical training with one of two interventional radiologists and followed the training with 1 month of supervised phantom-based practice. Thereafter, residents underwent final written and practical examinations. The practical examination included essential items from a 20-point checklist, including site and side marking, consent, time-out, and sterile technique along with a technical skills portion assessing pedal steps, radiation dose, needle redirects, and procedure time. The results indicated statistically significant improvement in procedural and technical skills after simulation training. For residents, the median number of pedal steps decreased by three (p=0.001), median dose decreased by 15.4 mGy (p<0.001), median procedure time decreased by 4.0 minutes (p<0.001), median number of needle redirects decreased by 1.0 (p=0.005), and median number of 20-point checklist items successfully completed increased by three (p<0.001). The results suggest that procedural skills can be acquired and improved by simulation-based training of residents, regardless of experience. CT simulation training decreases procedural time, decreases radiation dose, and improves resident efficiency and confidence, which may transfer to clinical practice with improved patient care and safety.

  20. Evaluation of Delcath Systems' Generation 2 (GEN 2) melphalan hemofiltration system in a porcine model of percutaneous hepatic perfusion.

    PubMed

    Moeslein, Fred M; McAndrew, Elizabeth G; Appling, William M; Hryniewich, Nicole E; Jarvis, Kevin D; Markos, Steven M; Sheets, Timothy P; Uzgare, Rajneesh P; Johnston, Daniel S

    2014-06-01

    A new melphalan hemoperfusion filter (GEN 2) was evaluated in a simulated-use porcine model of percutaneous hepatic perfusion (PHP). The current study evaluated melphalan filtration efficiency, the transfilter pressure gradient, and the removal of specific blood products. A porcine PHP procedure using the GEN 2 filter was performed under Good Laboratory Practice conditions to model the 60-min clinical PHP procedure. The mean filter efficiency for removing melphalan in six filters was 99.0 ± 0.4 %. The transfilter pressure gradient across the filter averaged 20.9 mmHg for the 60-min procedure. Many blood components, including albumin and platelets, decreased on average from 3.55 to 2.02 g/dL and from 342 to 177 × 10.e3/μL, respectively, during the procedure. The increased melphalan extraction efficiency of the new filter is expected to decrease systemic melphalan exposure. In addition, the low transfilter pressure gradient resulted in low resistance to blood flow in the GEN 2 filter, and the changes to blood components are expected to be clinically manageable.

  1. External cephalic version for breech presentation at term. A prospective interventional study.

    PubMed

    Al-Jwadi, Saja A; Al-Ibrahim, Baraa L Humo

    2014-08-01

    To evaluate the external cephalic version (ECV) procedure for the management of at term breech presenting fetuses. In this prospective, interventional study, 90 patients with uncomplicated breech presentations at or after 37 weeks' gestation were considered for ECV. This was performed in Al-Batool Teaching Hospital, Mosul, Iraq, between January 2011 and March 2012. The main outcome measure was assessed as the success rate of ECV attempt and the rate of cesarean section following a successful procedure. Parity, type of breech, placental location, and birth weight were evaluated as predictors of success. Also, any fetal or maternal complications during the procedure were evaluated. Data were analyzed by x2 test. Statistical significance was determined at a level of p<0.05. The success rate was 80%. The rate of cesarean section following successful procedure was only 12.5%. Prognostic parameters associated with successful ECV were multiparity and flexed type of breech. There were no serious fetal or maternal complications associated with the attempt. With appropriate selection of patients, ECV is highly successful and is a safer alternative to vaginal breech delivery or cesarean delivery.

  2. Advanced laparoscopic bariatric surgery Is safe in general surgery training.

    PubMed

    Kuckelman, John; Bingham, Jason; Barron, Morgan; Lallemand, Michael; Martin, Matthew; Sohn, Vance

    2017-05-01

    Bariatric surgery makes up an increasing percentage of general surgery training. The safety of resident involvement in these complex cases has been questioned. We evaluated patient outcomes in resident performed laparoscopic bariatric procedures. Retrospective review of patients undergoing a laparoscopic bariatric procedure over seven years at a tertiary care single center. Procedures were primarily performed by a general surgery resident and proctored by an attending surgeon. Primary outcomes included operative volume, operative time and leak rate with perioperative outcomes evaluated as secondary outcomes. A total of 1649 bariatric procedures were evaluated. Operations included laparoscopic bypass (690) and laparoscopic sleeve gastrectomy (959). Average operating time was 136 min. Eighteen leaks (0.67%) were identified. Graduating residents performed an average of 89 laparoscopic bariatric cases during their training. There were no significant differences between resident levels with concern to operative time or leak rate (p 0.97 and p = 0.54). General surgery residents can safely perform laparoscopic bariatric surgery. When proctored by a staff surgeon, a resident's level of training does not significantly impact leak rate. Published by Elsevier Inc.

  3. Colling Wipe Samples for VX Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koester, C; Hoppes, W G

    2010-02-11

    This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

  4. Development and Initial Evaluation of an Acceptance Testing Procedure for Air Supply and Distribution Systems in New Army Facilities

    DTIC Science & Technology

    1988-09-01

    Unfortunately, although current construction practices can produce functional HVAC systems that provide adequate heating and cooling , they do not guarantee...developed by interviewing heating, ventilating, and air-conditioning ( HVAC ) profes- sionals, reviewing technical literature, and consolidating these...for recording this information. A glossary of possibly unfamiliar HVAC terms is included. An informal evaluation of the procedure showed that

  5. Integrating Mobile Phones into Science Teaching to Help Students Develop a Procedure to Evaluate the Corrosion Rate of Iron in Simulated Seawater

    ERIC Educational Resources Information Center

    Moraes, Edgar P.; Confessor, Mario R.; Gasparotto, Luiz H. S.

    2015-01-01

    This article proposes an indirect method to evaluate the corrosion rate of iron nail in simulated seawater. The official procedure is based on the direct measurement of the specimen's weight loss over time; however, a highly precise scale is required and such equipment may not be easily available. On the other hand, mobile phones equipped with…

  6. An Evaluative Case Study: The Influence of Institutional Policies, Procedures, and Practices on Completion of Nontraditional Transfer Students at a Private, Religious-Based, Doctoral Degree-Granting, Moderate Research University

    ERIC Educational Resources Information Center

    Pack, Elizabeth Myra

    2017-01-01

    The purpose of this single, intrinsic, evaluative case study was to examine the problem of nontraditional transfer student completion at a private, religious-based, doctoral degree-granting, moderate research university in North Carolina. The following research questions guided the study: (a) How do institutional policies, procedures, and…

  7. Tools, harmonization and standardization procedures of the impact and outcome evaluation indices obtained during a kindergarten-based, family-involved intervention to prevent obesity in early childhood: the ToyBox-study.

    PubMed

    Mouratidou, T; Miguel, M L; Androutsos, O; Manios, Y; De Bourdeaudhuij, I; Cardon, G; Kulaga, Z; Socha, P; Galcheva, S; Iotova, V; Payr, A; Koletzko, B; Moreno, L A

    2014-08-01

    The ToyBox-intervention is a kindergarten-based, family-involved intervention targeting multiple lifestyle behaviours in preschool children, their teachers and their families. This intervention was conducted in six European countries, namely Belgium, Bulgaria, Germany, Greece, Poland and Spain. The aim of this paper is to provide a descriptive overview of the harmonization and standardization procedures of the baseline and follow-up evaluation of the study (and substudies). Steps related to the study's operational, standardization and harmonization procedures as well as the impact and outcome evaluation assessment tools used are presented. Experiences from the project highlight the importance of safeguarding the measurement process to minimize data heterogeneity derived from potential measurement error and country-by-country differences. In addition, it was made clear that continuing quality control and support is an important component of such studies. For this reason, well-supported communication channels, such as regular email updates and teleconferences, and regular internal and external meetings to ensure smooth and accurate implementation were in place during the study. The ToyBox-intervention and its harmonized and standardized procedures can serve as a successful case study for future studies evaluating the efficacy of similar interventions. © 2014 World Obesity.

  8. 30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... adherence to such procedures; (v) Welder and welding procedure qualification and identification; (vi... requirements, and evaluation results of the specified examinations; (viii) Destructive testing requirements and...

  9. Evaluation of Safety and Efficacy of the EndoLift Liver Retractor

    ClinicalTrials.gov

    2015-08-03

    Minimally Invasive Surgical Procedure; Laparoscopic Gastric Banding; Laparoscopic Roux-en-Y Gastric Bypass; Laparoscopic Sleeve Gastrectomy; Laparoscopic Fundoplication Procedure; Laparoscopic Heller Myotomy; Laparoscopic Paraesophageal Hernia Repair; Laparoscopic Gastric Resection

  10. Design and evaluation of instrument approach procedure charts

    DOT National Transportation Integrated Search

    1993-01-01

    A new format for instrument approach procedure : charts has been designed. Special attention was paid to : improving the readability of communication frequencies, : approach course heading and missed approach instructions. : Selected components of th...

  11. Liquefaction Resistance Based on Shear Wave Velocity

    DOT National Transportation Integrated Search

    1999-01-01

    This report reviews the current simplified procedures for evaluating the liquefaction resistance of granular soil deposits using small-strain shear wave velocity. These procedures were developed from analytical studies, laboratory studies, or very li...

  12. Minnesota low volume road design 1998

    DOT National Transportation Integrated Search

    1999-09-01

    In this project, researchers examined the current practices that local agencies use and evaluated the thickness design procedures by comparing predicted lives for the current designs with those obtained from the mechanistic-empirical design procedure...

  13. Flexible rotor balancing by the influence coefficient method. Part 1: Evaluation of the exact point-speed and least squares procedures

    NASA Technical Reports Server (NTRS)

    Tessarzik, J. M.

    1972-01-01

    The practical aspects of balancing real, flexible rotors were investigated through inclusion of rotor out-of-roundness data at the measurement probe locations. The computer program was demonstrated to be fully capable of handling out-of-roundness data in the investigation. Testing was performed predominantly with a machine having a 41-inch long, 126-pound rotor. This rotor was operated over a speed range encompassing three rotor-bearing system critical speeds. Both balancing procedures were evaluated for several different conditions of initial rotor unbalance. Safe (and slow) passage through all the critical speeds was obtained after two or three balancing runs in most cases. The Least Squares procedure was found to be generally equivalent in capability to the Exact Point-Speed procedure for the configurations studies. (U)

  14. Evaluating measurement models in clinical research: covariance structure analysis of latent variable models of self-conception.

    PubMed

    Hoyle, R H

    1991-02-01

    Indirect measures of psychological constructs are vital to clinical research. On occasion, however, the meaning of indirect measures of psychological constructs is obfuscated by statistical procedures that do not account for the complex relations between items and latent variables and among latent variables. Covariance structure analysis (CSA) is a statistical procedure for testing hypotheses about the relations among items that indirectly measure a psychological construct and relations among psychological constructs. This article introduces clinical researchers to the strengths and limitations of CSA as a statistical procedure for conceiving and testing structural hypotheses that are not tested adequately with other statistical procedures. The article is organized around two empirical examples that illustrate the use of CSA for evaluating measurement models with correlated error terms, higher-order factors, and measured and latent variables.

  15. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    PubMed

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  16. Tricuspid insufficiency after laser lead extraction.

    PubMed

    Rodriguez, Yasser; Mesa, Julian; Arguelles, Eric; Carrillo, Roger G

    2013-08-01

    The use of laser lead extraction (LLE) to remove pacemaker and implantable cardiac defibrillator leads has become more prevalent in the past decade. Though the procedure is associated with a low rate of complications, LLE still poses some risks to patients. Some reports have suggested an increase in tricuspid insufficiency (TI) associated with LLE. We present a series of patients who underwent both LLE and complete evaluation for TI with echocardiographic techniques. From August 2008 to January 2010, 173 prospective, consecutive patients underwent LLE in a single center. All patients had transesophageal echocardiograms (TEE) during the extraction. Fifty-three patients had tricuspid valve function evaluated a day before the procedure with a transthoracic echocardiogram (TTE), during the procedure with a TEE and 2 days postoperatively with a TTE. All 173 patients experienced no change in tricuspid valve function during the procedure with TEE. Of the 53 patients who underwent a complete TI evaluation, 38 were males (72%) and 15 females (38%), with a mean age of 69.45 ± 14.08. Mean ejection fraction was 35.82 ± 14.72. Three (6%) patients experienced TI after the procedure (two mild and one severe, all with tricuspid valve endocarditis); 16 (30%) patients were found to have TI before LLE that returned to normal valve function during or after the procedure. Thirty-four (64%) patients did not experience any significant change of the tricuspid valve performance after LLE. LLE was not associated with increased TI. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  17. Evaluability Assessment: A Retrospective Illustration and Review.

    ERIC Educational Resources Information Center

    Smith, Nick L.

    1981-01-01

    Rutman's view of evaluability assessment is reviewed, evaluation planning activities are illustrated via flow diagram for a large educational evaluation designed to increase citizen participation in local school activities, and some of the limitations of Rutman's evaluability procedures are outlined. (RL)

  18. Comparing Error Correction Procedures for Children Diagnosed with Autism

    ERIC Educational Resources Information Center

    Townley-Cochran, Donna; Leaf, Justin B.; Leaf, Ronald; Taubman, Mitchell; McEachin, John

    2017-01-01

    The purpose of this study was to examine the effectiveness of two error correction (EC) procedures: modeling alone and the use of an error statement plus modeling. Utilizing an alternating treatments design nested into a multiple baseline design across participants, we sought to evaluate and compare the effects of these two EC procedures used to…

  19. An Examination of Two Procedures for Identifying Consequential Item Parameter Drift

    ERIC Educational Resources Information Center

    Wells, Craig S.; Hambleton, Ronald K.; Kirkpatrick, Robert; Meng, Yu

    2014-01-01

    The purpose of the present study was to develop and evaluate two procedures flagging consequential item parameter drift (IPD) in an operational testing program. The first procedure was based on flagging items that exhibit a meaningful magnitude of IPD using a critical value that was defined to represent barely tolerable IPD. The second procedure…

  20. Using the Teaching Interactions Procedure to Teach Social Skills to Children with Autism and Intellectual Disability

    ERIC Educational Resources Information Center

    Ng, Aubrey Hui Shyuan; Schulze, Kim; Rudrud, Eric; Leaf, Justin B.

    2016-01-01

    This study implemented a modified teaching interaction procedure to teach social skills to 4 children diagnosed with autism spectrum disorder with an intellectual disability. A multiple baseline design across social skills and replicated across participants was utilized to evaluate the effects of the modified teaching interaction procedure. The…

Top