Blood Lead Toxicity Analysis of Multipurpose Canines and Military Working Dogs.
Reid, Paul; George, Clinton; Byrd, Christopher M; Miller, Laura; Lee, Stephen J; Motsinger-Reif, Alison; Breen, Matthew; Hayduk, Daniel W
Special Operations Forces and their accompanying tactical multipurpose canines (MPCs) who are involved in repeated live-fire exercises and military operations have the potential for increased blood lead levels and toxicity due to aerosolized and environmental lead debris. Clinical lead-toxicity symptoms can mimic other medical disorders, rendering accurate diagnosis more challenging. The objective of this study was to examine baseline lead levels of MPCs exposed to indoor firing ranges compared with those of nontactical military working dogs (MWDs) with limited or no exposure to the same environment. In the second part of the study, results of a commercially available, human-blood lead testing system were compared with those of a benchtop inductively coupled plasma-mass spectrometry (ICP-MS) analysis technique. Blood samples from 18 MPCs were tested during routine clinical blood draws, and six samples from a canine group with limited exposure to environmental lead (nontactical MWDs) were tested for comparison. There was a high correlation between results of the commercial blood-testing system compared with ICP-MS when blood lead levels were higher than 4.0µg/dL. Both testing methods recorded higher blood lead levels in the MPC blood samples than in those of the nontactical MWDs, although none of the MPC samples tested contained lead levels approaching those at which symptoms of lead toxicity have previously been reported in animals (i.e., 35µg/dL). 2018.
Dignam, Timothy A.; Evens, Anne; Eduardo, Eduard; Ramirez, Shokufeh M.; Caldwell, Kathleen L.; Kilpatrick, Nikki; Noonan, Gary P.; Flanders, W. Dana; Meyer, Pamela A.; McGeehin, Michael A.
2004-01-01
Objectives. We assessed the prevalence of elevated blood lead levels (≥ 10 micrograms of lead per deciliter of blood), risk factors, and previous blood lead testing among children in 2 high-risk Chicago, Ill, communities. Methods. Through high-intensity targeted screening, blood lead levels were tested and risks were assessed among a representative sample of children aged 1 to 5 years who were at risk for lead exposure. Results. Of the 539 children who were tested, 27% had elevated blood lead levels, and 61% had never been tested previously. Elevated blood lead levels were associated with chipped exterior house paint. Conclusions. Most of the children who lived in these communities—where the prevalence for elevated blood lead levels among children was 12 times higher than the national prevalence—were not tested for lead poisoning. Our findings highlight the need for targeted community outreach that includes testing blood lead levels in accordance with the American Academy of Pediatrics’ recommendations. PMID:15514235
Simulated airline service experience with laminar-flow control leading-edge systems
NASA Technical Reports Server (NTRS)
Maddalon, Dal V.; Fisher, David F.; Jennett, Lisa A.; Fischer, Michael C.
1987-01-01
The first JetStar leading edge flight test was made November 30, 1983. The JetStar was flown for more than 3 years. The titanium leading edge test articles today remain in virtually the same condition as they were in on that first flight. No degradation of laminar flow performance has occurred as a result of service. The JetStar simulated airline service flights have demonstrated that effective, practical leading edge systems are available for future commercial transports. Specific conclusions based on the results of the simulated airline service test program are summarized.
This report provides results for the verification testing of the Lead100/AND1000. The following is a description of the technology based on information provided by the vendor. The information provided below was not verified in this test. The ANDalyze Lead100/AND1000 was des...
Characterizing artifacts in RR stress test time series.
Astudillo-Salinas, Fabian; Palacio-Baus, Kenneth; Solano-Quinde, Lizandro; Medina, Ruben; Wong, Sara
2016-08-01
Electrocardiographic stress test records have a lot of artifacts. In this paper we explore a simple method to characterize the amount of artifacts present in unprocessed RR stress test time series. Four time series classes were defined: Very good lead, Good lead, Low quality lead and Useless lead. 65 ECG, 8 lead, records of stress test series were analyzed. Firstly, RR-time series were annotated by two experts. The automatic methodology is based on dividing the RR-time series in non-overlapping windows. Each window is marked as noisy whenever it exceeds an established standard deviation threshold (SDT). Series are classified according to the percentage of windows that exceeds a given value, based upon the first manual annotation. Different SDT were explored. Results show that SDT close to 20% (as a percentage of the mean) provides the best results. The coincidence between annotators classification is 70.77% whereas, the coincidence between the second annotator and the automatic method providing the best matches is larger than 63%. Leads classified as Very good leads and Good leads could be combined to improve automatic heartbeat labeling.
Elevated blood lead levels in refugee children--New Hampshire, 2003-2004.
2005-01-21
As a result of reductions in lead hazards and improved screening practices, blood lead levels (BLLs) in children aged 1-5 years are decreasing in the United States. However, the risk for elevated BLLs (> or =10 microg/dL) remains high for certain populations, including refugees. After the death of a Sudanese refugee child from lead poisoning in New Hampshire in 2000, the New Hampshire Department of Health and Human Services (NHDHHS) developed lead testing guidelines to screen and monitor refugee children. These guidelines recommend 1) capillary blood lead testing for refugee children aged 6 months-15 years within 3 months after arrival in New Hampshire, 2) follow-up venous testing of children aged <6 years within 3-6 months after initial screening, and 3) notation of refugee status on laboratory slips for first tests. In 2004, routine laboratory telephone reports of elevated BLLs to the New Hampshire Childhood Lead Poisoning Prevention Program (NHCLPPP) called attention to a pattern of elevated BLLs among refugee children. To develop prevention strategies, NHDHHS analyzed NHCLPPP and Manchester Health Department (MHD) data, focusing on the 37 African refugee children with elevated BLLs on follow-up for whom complete data were available. This report describes the results of that analysis, which indicated that 1) follow-up blood lead testing is useful to identify lead exposure that occurs after resettlement and 2) refugee children in New Hampshire older than those routinely tested might have elevated BLLs. Refugee children in all states should be tested for lead poisoning on arrival and several months after initial screening to assess exposure after resettlement.
Childhood lead poisoning investigations: evaluating a portable instrument for testing soil lead.
Reames, Ginger; Lance, Larrie L
2002-04-01
The Childhood Lead Poisoning Prevention Branch of the California Department of Health Services evaluated a portable X-ray fluorescence (XRF) instrument for use as a soil lead-testing tool during environmental investigations of lead-poisoned children's homes. A Niton XRF was used to test soil at 119 sampling locations in the yards of 11 San Francisco Bay Area houses. Niton XRF readings were highly correlated with laboratory results and met the study criteria for an acceptable screening method. The data suggest that the most health-protective and time-efficient approach to testing for soil lead above regulatory levels is to take either surface readings or readings of a test cup of soil prepared by grinding with a mortar and pestle. The advantage of the test cup method is that the test cup with soil may be submitted to a laboratory for confirmatory analysis.
[Roaming through methodology. XXXII. False test results].
van der Weijden, T; van den Akker, M
2001-05-12
The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.
Cumulative exposure to lead and cognition in persons with Parkinson’s disease
Weuve, Jennifer; Press, Daniel Z.; Grodstein, Francine; Wright, Robert O.; Hu, Howard; Weisskopf, Marc G.
2012-01-01
Background Dementia is an important consequence of Parkinson’s disease (PD), with few known modifiable risk factors. Cumulative exposure to lead, at levels experienced in the community, may exacerbate PD-related neural dysfunction, resulting in impaired cognition. Methods Among 101 persons with PD (“cases”) and, separately, 50 persons without PD (“controls”), we evaluated cumulative lead exposure, gauged via tibia and patella bone lead concentrations, in relation to cognitive function, assessed using a telephone battery developed and validated in a separate sample of PD patients. We also assessed the interaction between lead and case-control status. Results After multivariable adjustment, higher tibia bone lead concentration among PD cases was associated with worse performance on all of the individual telephone tests. In particular, tibia lead levels corresponded to significantly worse performance on a telephone analogue of the Mini-Mental State Examination and tests of working memory and attention. Moreover, higher tibia bone lead concentration was associated with significantly worse global composite score encompassing all the cognitive tests (P=0.04). The magnitude of association per standard deviation increment in tibia bone lead level was equivalent to the difference in global scores among controls in our study who were about seven years apart in age. The tibia lead-cognition association was notably stronger within cases than within controls (Pdifference=0.06). Patella bone lead concentration was not consistently associated with performance on the tests. Conclusions These data provide evidence suggesting that cumulative exposure to lead may result in worsened cognition among persons with PD. PMID:23143985
Impacts of road salts on leaching behavior of lead contaminated soil.
Wu, Jingjing; Kim, Hwidong
2017-02-15
Research was conducted to explore the effects of road salts on lead leaching from lead contaminated soil samples that were collected in an old residence area in Erie, PA. The synthetic precipitate leaching procedure (SPLP) test was employed to evaluate lead leaching from one of the lead contaminated soils in the presence of various levels of road salts (5%, 10%, 20%, 30% and 40%). The results of the leaching test showed that lead leaching dramatically increased as the road salt content increased as a result of the formation of lead-chloride complexes, but different lead leaching patterns were observed in the presence of NaCl- and CaCl 2 -based road salts at a high content of road salts (>20%). Additional leaching tests that include 30% road salts and different soil samples showed a variety of leaching patterns by soil samples. The sequential extraction of each soil sample showed that a high fraction of organic matter bound lead was associated with lead contamination. The higher the fraction of organic matter bound lead contained in soil, the greater the effects of calcium on reducing lead leaching, observations showed. Copyright © 2016 Elsevier B.V. All rights reserved.
Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William
2018-04-23
The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.
Addition of right-sided and posterior precordial leads during stress testing.
Shry, Eric A; Eckart, Robert E; Furgerson, James L; Stajduhar, Karl C; Krasuski, Richard A
2003-12-01
Exercise treadmill testing has limited sensitivity for the detection of coronary artery disease, frequently requiring the addition of imaging modalities to enhance the predictive value of the test. Recently, there has been interest in using nonstandard electrocardiographic (ECG) leads during exercise testing. We consecutively enrolled all patients undergoing exercise myocardial imaging with four additional leads recorded (V4R, V7, V8, and V9). The test characteristics of the 12-lead, the 15-lead (12-lead, V7, V8, V9), and the 16-lead (12-lead, V4R, V7, V8, V9) ECGs were compared with stress imaging in all patients. In the subset of patients who underwent angiography within 60 days of stress testing, these lead arrays were compared with the catheterization findings. There were 727 subjects who met entry criteria. The mean age was 58.5 +/- 12.3 years, and 366 (50.3%) were women. Pretest probability for disease was high in 241 (33.1%), intermediate in 347 (47.7%), and low in 139 (19.1%). A total of 166 subjects had an abnormal 12-lead ECG during exercise. The addition of 3 posterior leads to the standard 12-lead ECG resulted in 7 additional subjects having an abnormal electrocardiographic response to exercise. The addition of V4R resulted in only 1 additional patient having an abnormal ECG during exercise. The sensitivity of the ECG for detecting ischemia as determined by stress imaging was 36.6%, 39.2%, and 40.0% (P = NS) for the 12-lead, 15-lead, and 16-lead ECGs, respectively. In those with catheterization data (n = 123), the sensitivity for determining obstructive coronary artery disease was 43.5%, 45.2%, and 45.2% (P = NS) for the 12-lead, 15-lead, and 16-lead ECGs, respectively. The sensitivity of imaging modalities was 77.4% when compared with catheterization. In patients undergoing stress imaging studies, the addition of right-sided and posterior leads did not significantly increase the sensitivity of the ECG for the detection of myocardial ischemia. Additional leads should not be used to replace imaging modalities for the detection of coronary artery disease.
NASA Astrophysics Data System (ADS)
Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.
2017-12-01
Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10× magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.
Triantafyllidou, Simoni; Raetz, Meredith; Parks, Jeffrey; Edwards, Marc
2012-06-15
The lead leaching potential of new brass plumbing devices has come under scrutiny as a significant source of lead in drinking water (>300 μg/L) of new buildings around the world. Experiments were conducted using ball valves that were sold as certified and known to have caused problems in practice, in order to better understand how installed products could create such problems, even if they passed "leaching tests" such as National Sanitation Foundation (NSF) Standard 61 Section 8. Diffusion of lead from within the device into water when installed can increase lead leaching by orders of magnitude relative to results of NSF testing, which once only required exposure of very small volumes of water within the device. "Normalization" of the lead-in-water result tended to produce estimates of lead concentration that were much lower than actual lead measured at the tap. Finally, the presence of flux could also dramatically increase lead leaching, whereas high water velocity had relatively little effect. Copyright © 2012. Published by Elsevier Ltd.
Simulation Analysis of Helicopter Ground Resonance Nonlinear Dynamics
NASA Astrophysics Data System (ADS)
Zhu, Yan; Lu, Yu-hui; Ling, Ai-min
2017-07-01
In order to accurately predict the dynamic instability of helicopter ground resonance, a modeling and simulation method of helicopter ground resonance considering nonlinear dynamic characteristics of components (rotor lead-lag damper, landing gear wheel and absorber) is presented. The numerical integral method is used to calculate the transient responses of the body and rotor, simulating some disturbance. To obtain quantitative instabilities, Fast Fourier Transform (FFT) is conducted to estimate the modal frequencies, and the mobile rectangular window method is employed in the predictions of the modal damping in terms of the response time history. Simulation results show that ground resonance simulation test can exactly lead up the blade lead-lag regressing mode frequency, and the modal damping obtained according to attenuation curves are close to the test results. The simulation test results are in accordance with the actual accident situation, and prove the correctness of the simulation method. This analysis method used for ground resonance simulation test can give out the results according with real helicopter engineering tests.
Lead in school drinking water: Canada can and should address this important ongoing exposure source.
Barn, Prabjit; Kosatsky, Tom
2011-01-01
Reducing all preventable lead exposures in children should be a public health priority given that blood lead levels in children that were once considered "safe" have since been associated with important neuro-developmental deficits. Limited Canadian data indicate that school drinking water can be an important component of children's overall exposure to lead. Outside of Ontario, however, Canadian schools are not required to test for lead in water; in most of Canada, school testing is case by case, typically initiated by parental concerns. Provinces and territories are encouraged to follow Ontario's example by instituting a routine school water lead testing program in order to identify facilities where action can result in a decrease in students' exposure to lead. Testing and remediation frameworks developed by the US Environmental Protection Agency, Health Canada, and the province of Ontario provide direction to school boards and local and provincial/territorial health authorities.
Fischer, Avi; Klehn, Russell
2013-08-01
The insulation of St. Jude Medical Riata® leads contains a polytetrafluoroethylene (PTFE) liner, silicone tubing, and ethylenetetrafluoroethylene (ETFE) coating on individual cable conductors. ETFE has sufficient dielectric strength to assure electrical function. This investigation intended to analyze performance of leads with and without externalized conductors and with intact and breached ETFE. Testing was performed on ETFE-coated conductors to determine their ability to deliver high-voltage therapy. Tests were performed on samples under different conditions and current leakage was measured. A high-voltage test and a cyclic pulse test were performed, and the effect of lead modifications on the potential gradient from a high-voltage shock was used to determine functionality. Measurements from modified Riata® leads were compared with a control lead with all insulation and conducting elements intact. Current leakage for all conditions tested, was within the acceptance criteria for the high-voltage test and the cyclic pulse test. In conductors that underwent cyclic testing, the highest value of current leakage was within the limit of acceptability for both phases of the test. Testing of leads with externalized conductors and breached ETFE showed similar potential gradients compared with a control lead. Testing of ETFE-coated conductors following multiple preconditioning steps showed that ETFE serves as a redundant layer of insulation. In the event that the ETFE coating is breached, the potential gradient seen resulting from a high-voltage defibrillation shock was similar to a lead with no breach to the ETFE, even after 100 shocks.
Test results of 12/18 kA ReBCO coated conductor current leads
NASA Astrophysics Data System (ADS)
Kovalev, I. A.; Surin, M. I.; Naumov, A. V.; Novikov, M. S.; Novikov, S. I.; Ilin, A. A.; Polyakov, A. V.; Scherbakov, V. I.; Shutova, D. I.
2017-07-01
A pair of hybrid current leads (brass + stacked & soldered ReBCO tapes) rated for 12 kA in steady state and for up to 18 kA at pulsed over current conditions was designed, developed and tested at NRC ;Kurchatov Institute; (NRC ;KI;). During the experiment at LN2 temperature, the current leads (CLs) were successfully charged with 18 kA at 100 A/s ramp rate. To date, as far as we know, this is the highest current capacity achieved for 2G HTS current leads. The feasibility of ;stack-and-soldering technique; for 10 kA+ class coated conductor CLs for accelerators and fusion was demonstrated. This paper gives an overview of the leads design and presents the preliminary test results. Detailed studies of magnetic properties and current sharing process for the stacked and staggered HTS joints are also reported.
The effects of leading edge modifications on the post-stall characteristics of wings
NASA Technical Reports Server (NTRS)
Winkelmann, A. E.; Barlow, J. B.; Saini, J. K.; Anderson, J. D., Jr.; Jones, E.
1980-01-01
An investigation of the effects of leading edge modifications on the post-stall characteristics of two rectangular planform wings in a series of low speed wind tunnel tests is presented. Abrupt discontinuities in the leading edge shape of the wings were produced by placing a nose glove over a portion of the span or by deflecting sections of a segmented leading edge flap. Six component balance data, oil flow visualization photographs, and pressure distribution measurements were obtained, and tests made to study the development of flow separation at stall on small scale planform wing models. Results of oil flow visualization tests at and beyond stall showed the formation of counter-rotating swirl patterns on the upper surface of the '2-D' and '3-D' wings, and results of a numerical lifting line technique applied to wings with leading edge modifications are included.
Flight investigation of insect contamination and its alleviation
NASA Technical Reports Server (NTRS)
Peterson, J. B., Jr.; Fisher, D. F.
1978-01-01
An investigation of leading edge contamination by insects was conducted with a JetStar airplane instrumented to detect transition on the outboard leading edge flap and equipped with a system to spray the leading edge in flight. The results of airline type flights with the JetStar indicated that insects can contaminate the leading edge during takeoff and climbout. The results also showed that the insects collected on the leading edges at 180 knots did not erode at cruise conditions for a laminar flow control airplane and caused premature transition of the laminar boundary layer. None of the superslick and hydrophobic surfaces tested showed any significant advantages in alleviating the insect contamination problem. While there may be other solutions to the insect contamination problem, the results of these tests with a spray system showed that a continouous water spray while encountering the insects is effective in preventing insect contamination of the leading edges.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stenger, F.J.; Bozek, J.M.; Soltis, R.F.
1976-10-01
Five electric vehicles were tested at vehicle test tracks using the SAE. The tests provide range data at steady speeds and for several driving cycles. Most tests were conducted with lead-acid traction batteries. The Otis Van and the Copper Electric Town Car were also tested with lead-acid and nickel-zinc batteries. The tests showed a range increase of from 82 to 101 percent depending on vehicle, speed, and test cycle.
NASA Technical Reports Server (NTRS)
Stenger, F. J.; Bozek, J. M.; Soltis, R. F.
1976-01-01
Five electric vehicles were tested at vehicle test tracks using the SAE. The tests provide range data at steady speeds and for several driving cycles. Most tests were conducted with lead-acid traction batteries. The Otis Van and the Copper Electric Town Car were also tested with lead-acid and nickel-zinc batteries. The tests showed a range increase of from 82 to 101 percent depending on vehicle, speed, and test cycle.
Cumulative exposure to lead and cognition in persons with Parkinson's disease.
Weuve, Jennifer; Press, Daniel Z; Grodstein, Francine; Wright, Robert O; Hu, Howard; Weisskopf, Marc G
2013-02-01
Dementia is an important consequence of Parkinson's disease (PD), with few known modifiable risk factors. Cumulative exposure to lead, at levels experienced in the community, may exacerbate PD-related neural dysfunction, resulting in impaired cognition. Among 101 persons with PD ("cases") and, separately, 50 persons without PD ("controls"), we evaluated cumulative lead exposure, gauged by tibia and patella bone lead concentrations, in relation to cognitive function, assessed using a telephone battery developed and validated in a separate sample of PD patients. We also assessed the interaction between lead and case-control status. After multivariable adjustment, higher tibia bone lead concentration among PD cases was associated with worse performance on all of the individual telephone tests. In particular, tibia lead levels corresponded to significantly worse performance on a telephone analog of the Mini-Mental State Examination and tests of working memory and attention. Moreover, higher tibia bone lead concentration was associated with significantly worse global composite score encompassing all the cognitive tests (P = 0.04). The magnitude of association per standard deviation increment in tibia bone lead level was equivalent to the difference in global scores among controls in our study, who were approximately 7 years apart in age. The tibia lead-cognition association was notably stronger within cases than within controls (P(difference) = 0.06). Patella bone lead concentration was not consistently associated with performance on the tests. These data provide evidence suggesting that cumulative exposure to lead may result in worsened cognition among persons with PD. Copyright © 2012 Movement Disorders Society.
Factors associated with the seasonality of blood lead levels among preschool Wisconsin children.
Havlena, Jeff; Kanarek, Marty S; Coons, Margie
2009-05-01
Aggregate blood lead testing data for Wisconsin children younger than age 6 exhibit seasonal trends in both average blood lead levels and in the percent of those tested and found to have blood lead levels in excess of the 10 mcg/dL threshold for poisoning. Blood lead levels and poisoning rates typically peak during the late summer and early fall months, and are at their minimum during the late winter. Blood test data was analyzed to determine variations by month and age. Seasonal variations are evident even among the very young: infants younger than 10 months who likely have limited opportunity to encounter lead hazards within their home or in the outdoor soil. Seasonal periodicity is most evident among infants who reside in very urban and very rural communities. The observed seasonal periodicity might be associated with the seasonal availability of lead within the children's environment. Particulate matter data measured at several ambient air quality monitoring stations exhibit a similar periodic seasonality, suggesting a possible relationship between blood lead levels and the availability of dust and airborne particulates during the summer months. Clinicians should consider the seasonality of blood lead levels when scheduling tests and interpreting test results.
High Burden of Subclinical Lead Toxicity after Phase Out of Lead from Petroleum in Pakistan.
Majid, Hafsa; Khan, Aysha Habib; Khan, Nadeem Ullah; Siddiqui, Imran; Ghani, Farooq; Jafri, Lena
2017-12-01
To evaluate the frequency of subclinical lead toxicity. Cross-sectional study. Department of Pathology and Laboratory Medicine, The Aga Khan University Hospital, Karachi, from January 2011 to December 2014. Analysis of laboratory data for blood lead levels (BLL) was performed. Lead was tested by atomic absorption spectrometer. For all subjects, only initial test results were included while the results of repeated testing were excluded. Exemption was sought from institutional ethical review committee. BLL of 2-10 ug/dl and 10-70 ug/dl in children and adults, respectively were taken as subclinical lead toxicity. Amongst the total number of subjects tested (n=524), 26.5% (n=139) were children (<16 years) while rest were adults. Overall median BLLs was 6.4 ug/dl (20.9-3.1). The median BLL was 4 ug/dl (6.7-2.6) in children and 8.3 ug/dl (27.9-3.4) in adults, respectively. The BLL increased with age; higher levels were observed in age range 21-30 years of subjects [median lead level 16.9 ug/dl (36.1-4)] and lower level [4.2 ug/dl (6.8-2.6)] in children with <10 years of age. Only 16% (n=22) children had desirable lead levels while most had either subclinical (76%, n=106) or toxic lead levels (8%, n=11). In adults, (55%, n=212) subjects had desired lead levels, and 40% (n=154) and 4.99% (n=19) had subclinical and toxic lead levels. Presence of subclinical lead poisoning even after phasing out of lead petroleum in Pakistanis is alarming, especially in children. A national population-based study to determine the lead status and targeted intervention to identify potential sources is need of the time.
The Pollution Detectives, Part III: Roadside Lead Pollution.
ERIC Educational Resources Information Center
Sanderson, Phil
1989-01-01
Described is a simple test tube method developed lead analysis of samples of roadside soil. The relationship between the results and the traffic flow indicate car exhausts are the major source of lead pollution. Materials and procedures are detailed. An example of results is provided. (Author/CW)
Test and Analysis of a Hyper-X Carbon-Carbon Leading Edge Chine
NASA Technical Reports Server (NTRS)
Smith, Russell W.; Sikora, Joseph G.; Lindell, Michael C.
2005-01-01
During parts production for the X43A Mach 10 hypersonic vehicle nondestructive evaluation (NDE) of a leading edge chine detected on imbedded delamination near the lower surface of the part. An ultimate proof test was conducted to verify the ultimate strength of this leading edge chine part. The ultimate proof test setup used a pressure bladder design to impose a uniform distributed pressure field over the bi-planar surface of the chine test article. A detailed description of the chine test article and experimental test setup is presented. Analysis results from a linear status model of the test article are also presented and discussed. Post-test inspection of the specimen revealed no visible failures or areas of delamination.
Genotoxicity testing of two lead-compounds in somatic cells of Drosophila melanogaster.
Carmona, Erico R; Creus, Amadeu; Marcos, Ricard
2011-09-18
The in vivo genotoxic activity of two inorganic lead compounds was studied in Drosophila melanogaster by measurement of two different genetic endpoints. We used the wing-spot test and the comet assay. The comet assay was conducted with larval haemocytes. The results from the wing-spot test showed that neither lead chloride, PbCl(2), nor lead nitrate, Pb(NO(3))(2), were able to induce significant increases in the frequency of mutant spots. In addition, the combined treatments with gamma-radiation and PbCl(2) or Pb(NO(3))(2) did not show significant variations in the frequency of the three categories of mutant spots recorded, compared with the frequency induced by gamma-radiation alone. This seems to indicate that the lead compounds tested do not interact with the repair of the genetic damage induced by ionizing radiation. When the lead compounds were evaluated in the in vivo comet assay with haemocytes, Pb(NO(3))(2) was effective in inducing significant increases of DNA damage with a direct dose-response pattern. These results confirm the usefulness of the comet assay with haemocytes as an in vivo model and support the assumption that there is a genotoxic risk associated with lead exposure. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1979-01-01
Configurations with full-span and segmented leading-edge flaps and full-span and segmented leading-edge droop were tested. Studies were conducted with wind-tunnel models, with an outdoor radio-controlled model, and with a full-scale airplane. Results show that wing-leading-edge modifications can produce large effects on stall/spin characteristics, particularly on spin resistance. One outboard wing-leading-edge modification tested significantly improved lateral stability at stall, spin resistance, and developed spin characteristics.
NASA Technical Reports Server (NTRS)
Maddalon, Dal V.; Braslow, Albert L.
1990-01-01
The effectiveness and practicality of candidate leading edge systems for suction laminar flow control transport airplanes were investigated in a flight test program utilizing a modified JetStar airplane. The leading edge region imposes the most severe conditions on systems required for any type of laminar flow control. Tests of the leading edge systems, therefore, provided definitive results as to the feasibility of active laminar flow control on airplanes. The test airplane was operated under commercial transport operating procedures from various commercial airports and at various seasons of the year.
Batteries for Electric Vehicles
NASA Technical Reports Server (NTRS)
Conover, R. A.
1985-01-01
Report summarizes results of test on "near-term" electrochemical batteries - (batteries approaching commercial production). Nickel/iron, nickel/zinc, and advanced lead/acid batteries included in tests and compared with conventional lead/acid batteries. Batteries operated in electric vehicles at constant speed and repetitive schedule of accerlerating, coasting, and braking.
2010-01-01
Background Despite indoor home environments being where people spend most time, involving residents in testing those environments has been very limited, especially in marginalized communities. We piloted participatory testing and reporting that combined relatively simple tests with actionable reporting to empower residents in Main South/Piedmont neighborhoods of Worcester, Massachusetts. We answered: 1) How do we design and implement the approach for neighborhood and household environments using participatory methods? 2) What do pilot tests reveal? 3) How does our experience inform testing practice? Methods The approach was designed and implemented with community partners using community-based participatory research. Residents and researchers tested fourteen homes for: lead in dust indoors, soil outdoors, paint indoors and drinking water; radon in basement air; PM2.5 in indoor air; mold spores in indoor/outdoor air; and drinking water quality. Monitoring of neighborhood particulates by residents and researchers used real-time data to stimulate dialogue. Results Given the newness of our partnership and unforeseen conflicts, we achieved moderate-high success overall based on process and outcome criteria: methods, test results, reporting, lessons learned. The conflict burden we experienced may be attributable less to generic university-community differences in interests/culture, and more to territoriality and interpersonal issues. Lead-in-paint touch-swab results were poor proxies for lead-in-dust. Of eight units tested in summer, three had very high lead-in-dust (>1000 μg/ft2), six exceeded at least one USEPA standard for lead-in-dust and/or soil. Tap water tests showed no significant exposures. Monitoring of neighborhood particulates raised awareness of environmental health risks, especially asthma. Conclusions Timely reporting back home-toxics' results to residents is ethical but it must be empowering. Future work should fund the active participation of a few motivated residents as representatives of the target population. Although difficult and demanding in time and effort, the approach can educate residents and inform exposure assessment. It should be considered as a core ingredient of comprehensive household toxics' testing, and has potential to improve participant retention and the overall positive impact of long-term environmental health research efforts. PMID:20604953
Migration protocol to estimate metal exposure from mouthing copper and tin alloy objects
2014-01-01
Background Low blood lead levels previously thought to pose no health risks may have an adverse impact on the cognitive development of children. This concern has given rise to new regulatory restrictions upon lead metal containing products intended for child use. However few reliable experimental testing methods to estimate exposure levels from these materials are available. Methods The present work describes a migration test using a mimetic saliva fluid to estimate the chronic exposure of children to metals such as lead while mouthing metallic objects. The surrogate saliva medium was composed of: 150 mM NaCl, 0.16% porcine Mucin and 5 mM buffer MOPS, adjusted to pH 7.2. Alloys samples, in the form of polished metallic disc of known surface area, were subjected to an eight hours test. Results Two whitemetal alloys Sn/Pb/Sb/Cu and three brass alloys Cu/Zn/Pb were tested using the saliva migration protocol. In the case of the whitemetal alloys, first order release kinetics resulting in the release of 0.03 and 0.51 μg lead/cm2 after 8 hours of tests were observed, for lead contents of 0.05-0.07% and 5.5%, respectively. Brasses exhibited linear incremental release rates of 0.043, 0.175 and 0.243 μg lead/cm2h for lead contents of 0.1-0.2%, 1.7-2.2% and 3.1-3.5%, respectively. The linear regression analysis of lead release rates relative to Pb content in brasses yielded a slope of 0.08 μg lead/cm2h%Pb (r2 = 0.92). Lead release rates were used to estimate the mean daily mouthing exposure of a child to lead, according to age-specific estimates of mouthing time behavior. Calculated daily intakes were used as oral inputs for the IEUBK toxicokinetic model, predicting only marginal changes in blood lead levels (0.2 μg lead/dL or less) for children aged 0.5 to 1 years old exposed to either class of alloy. Conclusions The results of this study as a whole support the use of migration data of metal ions, rather than total metal content, to estimate health risk from exposure to metals and metal alloys substances in children. PMID:25113236
The leaching of lead from lead-based paint in landfill environments.
Wadanambi, Lakmini; Dubey, Brajesh; Townsend, Timothy
2008-08-30
Lead leaching from lead-based paint (LBP) was examined using standardized laboratory protocols and tests with leachate from actual and simulated landfill environments. Two different LBP samples were tested; leaching solutions included leachates from three municipal solid waste (MSW) landfills and three construction and demolition (C&D) debris landfills. The toxicity characteristic leaching procedure (TCLP) and the synthetic precipitation leaching procedure (SPLP) were also performed. Lead concentrations were many times higher using the TCLP compared to the SPLP and the landfill leachates. No significant difference (alpha=0.05) was observed in leached lead concentrations from the MSW landfill and C&D debris landfill leachates. The impact of other building materials present in LBP debris on lead leaching was examined by testing mixtures of LBP (2%) and different building materials (98%; steel, wood, drywall, concrete). The type of substrate present impacted lead leaching results, with concrete demonstrating the most dramatic impact; the lowest lead concentrations were measured in the presence of concrete under both TCLP and SPLP extractions.
Ferrie, Joseph P; Rolf, Karen; Troesken, Werner
2012-01-01
Higher prior exposure to water-borne lead among male World War Two U.S. Army enlistees was associated with lower intelligence test scores. Exposure was proxied by urban residence and the water pH levels of the cities where enlistees lived in 1930. Army General Classification Test scores were six points lower (nearly 1/3 standard deviation) where pH was 6 (so the water lead concentration for a given amount of lead piping was higher) than where pH was 7 (so the concentration was lower). This difference rose with time exposed. At this time, the dangers of exposure to lead in water were not widely known and lead was ubiquitous in water systems, so these results are not likely the effect of individuals selecting into locations with different levels of exposure. Copyright © 2011 Elsevier B.V. All rights reserved.
Chen, Eugene; Abbott, Paul V.
2009-01-01
Dental pulp testing is a useful and essential diagnostic aid in endodontics. Pulp sensibility tests include thermal and electric tests, which extrapolate pulp health from sensory response. Whilst pulp sensibility tests are the most commonly used in clinical practice, they are not without limitations and shortcomings. Pulp vitality tests attempt to examine the presence of pulp blood flow, as this is viewed as a better measure of true health than sensibility. Laser Doppler flowmetry and pulse oximetry are examples of vitality tests. Whilst the prospect is promising, there are still many practical issues that need to be addressed before vitality tests can replace sensibility tests as the standard clinical pulp diagnostic test. With all pulp tests, the results need to be carefully interpreted and closely scrutinised as false results can lead to misdiagnosis which can then lead to incorrect, inappropriate, or unnecessary treatment. PMID:20339575
Random left censoring: a second look at bone lead concentration measurements
NASA Astrophysics Data System (ADS)
Popovic, M.; Nie, H.; Chettle, D. R.; McNeill, F. E.
2007-09-01
Bone lead concentrations measured in vivo by x-ray fluorescence (XRF) are subjected to left censoring due to limited precision of the technique at very low concentrations. In the analysis of bone lead measurements, inverse variance weighting (IVW) of measurements is commonly used to estimate the mean of a data set and its standard error. Student's t-test is used to compare the IVW means of two sets, testing the hypothesis that the two sets are from the same population. This analysis was undertaken to assess the adequacy of IVW in the analysis of bone lead measurements or to confirm the results of IVW using an independent approach. The rationale is provided for the use of methods of survival data analysis in the study of XRF bone lead measurements. The procedure is provided for bone lead data analysis using the Kaplan-Meier and Nelson-Aalen estimators. The methodology is also outlined for the rank tests that are used to determine whether two censored sets are from the same population. The methods are applied on six data sets acquired in epidemiological studies. The estimated parameters and test statistics were compared with the results of the IVW approach. It is concluded that the proposed methods of statistical analysis can provide valid inference about bone lead concentrations, but the computed parameters do not differ substantially from those derived by the more widely used method of IVW.
NASA Technical Reports Server (NTRS)
Hickey, David H.; Aoyagi, Kiyoshi
1960-01-01
A wind-tunnel investigation was conducted to determine the effect of trailing-edge flaps with blowing-type boundary-layer control and leading-edge slats on the low-speed performance of a large-scale jet transport model with four engines and a 35 deg. sweptback wing of aspect ratio 7. Two spanwise extents and several deflections of the trailing-edge flap were tested. Results were obtained with a normal leading-edge and with full-span leading-edge slats. Three-component longitudinal force and moment data and boundary-layer-control flow requirements are presented. The test results are analyzed in terms of possible improvements in low-speed performance. The effect on performance of the source of boundary-layer-control air flow is considered in the analysis.
Method and apparatus for diagnosis of lead toxicity
Rosen, John F.; Slatkin, Daniel N.; Wielopolski, Lucian
1989-01-01
Improved methods and apparatus for in vivo measurement of the skeletal lead burden of a patient and for diagnosis of lead toxicity are disclosed. The apparatus comprises an x-ray tube emitting soft low energy x-rays from a silver anode, a polarizer for polarizing the emitted x-rays, and a detector for detecting photons fluoresced from atoms in the patient's tibia upon irradiation by the polarized x-rays. The fluoresced photons are spectrally analyzed to determine their energy distribution. Peaks indicating the presence of lead are identified if the patient has relatively high bone lead content. The data may be compared to data recorded with respect to a similar test performed on patients having also had the conventional EDTA chelation tests performed thereon in order to correlate the test results with respect to a particular patient to the conventionally accepted EDTA chelation test.
NASA Technical Reports Server (NTRS)
Hahne, Daniel E.
1999-01-01
Using the F-16XL as a test-bed, two strategies for improving the low-speed flying characteristics that had minimal impact on high-speed performance were evaluated. In addition to the basic F-16XL configuration several modifications to the baseline configuration were tested in the Langley 30- X 60-Foot Tunnel: 1) the notched area at the wing leading edge and fuselage juncture was removed resulting in a continuous 70 deg leading-edge sweep on the inboard portion of the wing; 2) an integral attached-flow leading-edge flap concept was added to the continuous leading edge; and 3) a deployable vortex flap concept was added to the continuous leading edge. The purpose of this report is simply to document the test configurations, test conditions, and data obtained in this investigation for future reference and analysis. No analysis is presented herein and the data only appear in tabulated format.
Experience of 12 kA / 16 V SMPS during the HTS Current Leads Test
NASA Astrophysics Data System (ADS)
Panchal, P.; Christian, D.; Panchal, R.; Sonara, D.; Purwar, G.; Garg, A.; Nimavat, H.; Singh, G.; Patel, J.; Tanna, V.; Pradhan, S.
2017-04-01
As a part of up gradation plans in SST-1 Tokamak, one pair of 3.3 kA rated prototype hybrid current leads were developed using Di-BSCCO as High Temperature Superconductors (HTS) and the copper heat exchanger. In order to validate the manufacturing procedure prior to go for series production of such current leads, it was recommended to test these current leads using dedicated and very reliable DC switch mode power supply (SMPS). As part of test facility, 12 kA, 16 VDC programmable SMPS was successfully installed, commissioned and tested. This power supply has special features such as modularity, N+1 redundancy, very low ripple voltage, precise current measurements with Direct Current Current Transformer, CC/CV modes with auto-crossover and auto-sequence programming. As a part of acceptance of this converter, A 5.8 mΩ water-cooled resistive dummy load and PLC based SCADA system is designed, developed for commissioning of power supply. The same power supply was used for the testing of the prototype HTS current leads. The paper describes the salient features and experience of state-of-art of power supply and results obtained from this converter during the HTS current leads test.
Development flight tests of JetStar LFC leading-edge flight test experiment
NASA Technical Reports Server (NTRS)
Fisher, David F.; Fischer, Michael C.
1987-01-01
The overall objective of the flight tests on the JetStar aircraft was to demonstrate the effectiveness and reliability of laminar flow control under representative flight conditions. One specific objective was to obtain laminar flow on the JetStar leading-edge test articles for the design and off-design conditions. Another specific objective was to obtain operational experience on a Laminar Flow Control (LFC) leading-edge system in a simulated airline service. This included operational experience with cleaning requirements, the effect of clogging, possible foreign object damage, erosion, and the effects of ice particle and cloud encounters. Results are summarized.
Novel handheld x-ray fluorescence spectrometer for routine testing for the presence of lead
NASA Astrophysics Data System (ADS)
Rensing, Noa M.; Tiernan, Timothy C.; Squillante, Michael R.
2011-06-01
RMD is developing a safe, inexpensive, and easy to operate lead detector for retailers and consumers that can reliably detect dangerous levels of lead in toys and other household products. Lead and its compounds have been rated as top chemicals that pose a great threat to human health. However, widespread testing for environmental lead is rarely undertaken until lead poisoning has already been diagnosed. The problem is not due to the accuracy or sensitivity of existing lead detection technology, but rather to the high expense, safety and licensing barriers of available test equipment. An inexpensive and easy to use lead detector would enable the identification of highly contaminated objects and areas and allow for timely and cost effective remediation. The military has similar needs for testing for lead and other heavy elements such as mercury, primarily in the decontamination of former military properties prior to their return to civilian use. RMD's research and development efforts are abased on advanced solid-state detectors combined with recently patented lead detection techniques to develop a consumer oriented lead detector that will be widely available and easy and inexpensive to use. These efforts will result in an instrument that offers: (1) high sensitivity, to identify objects containing dangerous amounts of lead, (2) low cost to encourage widespread testing by consumers and other end users and (3) convenient operation requiring no training or licensing. In contrast, current handheld x-ray fluorescence spectrometers either use a radioactive source requiring licensing and operating training, or use an electronic x-ray source that limits their sensitivity to surface lead.
Handley, Margaret A; Nelson, Kali; Sanford, Eric; Clarity, Cassidy; Emmons-Bell, Sophia; Gorukanti, Anuhandra; Kennelly, Patrick
2017-10-26
In California, the annual number of children under age 6 y of age with blood lead levels (BLL) ≥10μg/dL is estimated at over 1,000 cases, and up to 10,000 cases when BLL between 4.5 and 9.5 μg/dL are included. State-issued health alerts for food contamination provide one strategy for tracking sources of food-related lead exposures. As well, California passed legislation in 2006 for the Food and Drug Branch (FDB) of the state health department to test and identify lead in candy. This report presents health alert data from California over a 14-y period, compares data before and after the candy testing program began, and examines country of origin, ZIP code data, and time from candy testing to release of health alerts for lead-contaminated candies for 2011-2012. After 2007, health alerts issued for lead in candy and food increased significantly. Analysis of candy-testing data indicated that multiple counties and ZIP codes were affected. Seventeen candies with high lead concentrations were identified, resulting in rapid dissemination (<2wk) of health alerts to local health departments and community clinicians and to the public. Surveillance of lead exposures from state-based food and candy testing programs provides an opportunity to identify and immediately act to remove nonpaint sources of lead affecting children. https://doi.org/10.1289/EHP2582.
Battery/Ultracapacitor Evaluation for X-38 Crew Return Vehicle (CRV)
NASA Technical Reports Server (NTRS)
Darcy, Eric; Strangways, Bradley
1999-01-01
This presentation reported on the evaluation of the battery/ultracapacitor for the crew return vehicle (CRV). The CRV, as part of the international space station (ISS) planning, will be available to return to earth an ill or injured crew person, or if the ISS becomes unsafe, and the shuttle is not available. The requirements of the X-38 CRV are reviewed, and in light of the power requirements, the battery's required performance is reviewed. The ultracapacitor bank, and its test method is described. The test results are reviewed. A picture of the test set up is displayed showing the ultracapacitor bank and the NiMH battery. The presentation continues by reviewing tests of 5 available trade high power cell designs: (1) Hawker lead acid, (2) Bolder lead acid, (3) Energizer NiMH, (4) Sanyo NiCd, and (5) Energizer NiCd. The test methods and results are reviewed. There is also a review of the issues concerning lead acid batteries and conclusions.
Alleviation of Facility/Engine Interactions in an Open-Jet Scramjet Test Facility
NASA Technical Reports Server (NTRS)
Albertson, Cindy W.; Emami, Saied
2001-01-01
Results of a series of shakedown tests to eliminate facility/engine interactions in an open-jet scramjet test facility are presented. The tests were conducted with the NASA DFX (Dual-Fuel eXperimental scramjet) engine in the NASA Langley Combustion Heated Scramjet Test Facility (CHSTF) in support of the Hyper-X program, The majority of the tests were conducted at a total enthalpy and pressure corresponding to Mach 5 flight at a dynamic pressure of 734 psf. The DFX is the largest engine ever tested in the CHSTF. Blockage, in terms of the projected engine area relative to the nozzle exit area, is 81% with the engine forebody leading edge aligned with the upper edge of the facility nozzle such that it ingests the nozzle boundary layer. The blockage increases to 95% with the engine forebody leading edge positioned 2 in. down in the core flow. Previous engines successfully tested in the CHSTF have had blockages of no more than 51%. Oil flow studies along with facility and engine pressure measurements were used to define flow behavior. These results guided modifications to existing aeroappliances and the design of new aeroappliances. These changes allowed fueled tests to be conducted without facility interaction effects in the data with the engine forebody leading edge positioned to ingest the facility nozzle boundary layer. Interaction effects were also reduced for tests with the engine forebody leading edge positioned 2 in. into the core flow, however some interaction effects were still evident in the engine data. A new shroud and diffuser have been designed with the goal of allowing fueled tests to be conducted with the engine forebody leading edge positioned in the core without facility interaction effects in the data. Evaluation tests of the new shroud and diffuser will be conducted once ongoing fueled engine tests have been completed.
Blood Lead Level Among Fuel Station Workers
Al-Rudainy, Laith Abdulmajeed
2010-01-01
Objectives This study aims to determine the level of lead in blood of fuel station workers and in a group of people not occupationally exposed to lead Methods 53 control subjects with low risk lead exposure and 45 fuel station workers comprising the study group were included in this study in a period from September 2008 to December 2009. Blood samples were collected and analyzed for each subject by Lead Care Blood Testing System. The average blood lead levels of each group were compared using the independent sample (Mann – Whitney U) test. Results The median (range) 14.1 (7.5–56) μg/dl concentration of lead in the blood of fuel stations workers was significantly higher than the median (range) 6.5 (4.0–1.6) μg/dl concentration of lead in the blood of the control group (p< 0.001).The results obtained also showed that the values of blood lead levels in many workers were higher than action and upper limits acceptable for adults. In fuel station workers, the duration of exposure to leaded fuel was significantly correlated with the blood lead level. Conclusions Occupational exposure to lead is prevalent among many fuel station workers in Basrah. A policy action to improve working conditions and to phase out the use of leaded gasoline is recommended. PMID:22043339
Dynamic Stall Measurements and Computations for a VR-12 Airfoil with a Variable Droop Leading Edge
NASA Technical Reports Server (NTRS)
Martin, P. B.; McAlister, K. W.; Chandrasekhara, M. S.; Geissler, W.
2003-01-01
High density-altitude operations of helicopters with advanced performance and maneuver capabilities have lead to fundamental research on active high-lift system concepts for rotor blades. The requirement for this type of system was to improve the sectional lift-to-drag ratio by alleviating dynamic stall on the retreating blade while simultaneously reducing the transonic drag rise of the advancing blade. Both measured and computational results showed that a Variable Droop Leading Edge (VDLE) airfoil is a viable concept for application to a rotor high-lift system. Results are presented for a series of 2D compressible dynamic stall wind tunnel tests with supporting CFD results for selected test cases. These measurements and computations show a dramatic decrease in the drag and pitching moment associated with severe dynamic stall when the VDLE concept is applied to the Boeing VR-12 airfoil. Test results also show an elimination of the negative pitch damping observed in the baseline moment hysteresis curves.
Rollin, L; Carré, N; Garnier, R
2008-12-01
It is essential for children suffering from or at risk of lead poisoning to have regular follow-up, and specifically for their blood lead (Pb) levels to be monitored. The present study assessed the occurrence of late follow-up testing of blood lead levels in children in Greater Paris, and factors related to such delays. Since 1992, the SSSIILF has been systematically recording data on lead levels in blood tests conducted for screening and follow-up in Greater Paris. For Pb greater or equal to 45 microg/dL (Group 4), a further blood lead test has to be done within three weeks. For levels of 25 microg/dL < or = Pb < 45 microg/dL (Group 3) and 10 microg/dL < or = Pb < 25 microg/dL (Group 2), a second test must be done within 6 months. For Pb less than 10 microg/dL combined with one or more risk factors (Group 1: children at risk of poisoning), a second test is required within 6 to 12 months. Children aged 1 to 6 years who were screened between 1992 and 2002 were selected. The occurrence of late follow-up testing was estimated, and the independent effect of each variable associated with a delay was measured using a logistic regression model. Delays in re-testing were reported for 66.9% of Group 4 children (n=356), 45.3% of Group 3 children (n=921), 74.1% of Group 2 children (n=5,466), and 88.7% of Group 1 children (n=15,612). In the three groups with Pb greater or equal to 10 microg/dL, there was better follow-up (i.e. less delay to re-testing) for children screened most recently, those whose initial blood lead test results were elevated, those who lived in sub-standard housing built before 1949, and those who lived in suburban districts of Paris. The delay was longer for children aged 4 to 6 compared to younger children. When the size of the group was large enough, these differences were significant. In Group 1, similar results were observed except for a home address in a suburban district. Furthermore, follow-up was better for children of Sub-Saharan African parents, children whose initial prescription had been issued by a "PMI" mother/child healthcare centre and children from large families. Despite substantial delays in carrying out follow-up blood lead level testing, these delays were shorter for the populations with the greatest exposure.
NASA Astrophysics Data System (ADS)
Hakim, I.; May, D.; Abo Ras, M.; Meyendorf, N.; Donaldson, S.
2016-04-01
On the present work, samples of carbon fiber/epoxy composites with different void levels were fabricated using hand layup vacuum bagging process by varying the pressure. Thermal nondestructive methods: thermal conductivity measurement, pulse thermography, pulse phase thermography and lock-in-thermography, and mechanical testing: modes I and II interlaminar fracture toughness were conducted. Comparing the parameters resulted from the thermal nondestructive testing revealed that voids lead to reductions in thermal properties in all directions of composites. The results of mode I and mode II interlaminar fracture toughness showed that voids lead to reductions in interlaminar fracture toughness. The parameters resulted from thermal nondestructive testing were correlated to the results of mode I and mode II interlaminar fracture toughness and voids were quantified.
Lead induced stress corrosion cracking of Alloy 690 in high temperature water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, K.K.; Lim, J.K.; Moriya, Shinichi
1995-12-31
Recent investigations of cracked steam generator tubes at nuclear power plants concluded that lead significantly contributed to cracking the Alloy 600 materials. In order to investigate the stress corrosion cracking (SCC) behavior of Alloy 690, slow strain rate tests (SSRT) and anodic polarization measurements were performed. The SSRTs were conducted in a lead-chloride solution (PbCl{sub 2}) and in a chloride but lead free solution (NaCl) at pH of 3 and 4.5 at 288 C. The anodic polarization measurements were carried out at 30 C using the same solutions as in SSRT. The SSRT results showed that Alloy 690 was susceptiblemore » to SCC in both solutions. In the lead chloride solution, cracking had slight dependence on lead concentration and pH. Cracking tend to increase with a higher lead concentration and a lower pH and was mainly intergranular and was to be a few tens to hundreds micrometers in length. In the chloride only solution, cracking was similar to the lead induced SCC. The results of anodic polarization measurement and electron probe micro analysis (EPMA) helped to understand lead induced SCC. Lead was a stronger active corrosive element but had a minor affect on cracking susceptibility of the alloy. While, chloride was quite different from lead effect to SCC. A possible mechanism of lead induced SCC of Alloy 690 was also discussed based on the test results.« less
NASA Technical Reports Server (NTRS)
Glass, Christopher E.
1989-01-01
The effects of cylindrical leading edge sweep on surface pressure and heat transfer rate for swept shock wave interference were investigated. Experimental tests were conducted in the Calspan 48-inch Hypersonic Shock Tunnel at a nominal Mach number of 8, nominal unit Reynolds number of 1.5 x 10 to the 6th power per foot, leading edge and incident shock generator sweep angles of 0, 15, and 30 deg, and incident shock generator angle-of-attack fixed at 12.5 deg. Detailed surface pressure and heat transfer rate on the cylindircal leading edge of a swept shock wave interference model were measured at the region of the maximum surface pressure and heat transfer rate. Results show that pressure and heat transfer rate on the cylindrical leading edge of the shock wave interference model were reduced as the sweep was increased over the range of tested parameters. Peak surface pressure and heat transfer rate on the cylinder were about 10 and 30 times the undisturbed flow stagnation point value, respectively, for the 0 deg sweep test. A comparison of the 15 and 30 deg swept results with the 0 deg swept results showed that peak pressure was reduced about 13 percent and 44 percent, respectively, and peak heat transfer rate was reduced about 7 percent and 27 percent, respectively.
Reliability evaluation of hermetic dual in-line flat microcircuit packages
NASA Technical Reports Server (NTRS)
Johnson, G. M.; Conaway, L. K.
1977-01-01
The relative strengths and weaknesses of 35 commonly used hermetic flat and dual in-line packages were determined and used to rank each of the packages according to a numerical weighting scheme for package attributes. The list of attributes included desirable features in five major areas: lead and lead seal, body construction, body materials, lid and lid seal, and marking. The metal flat pack and multilayer integral ceramic flat pack and DIP received the highest rankings, and the soft glass Cerdip and Cerpak types received the lowest rankings. Loss of package hermeticity due to lead and lid seal problems was found to be the predominant failure mode from the literature/data search. However, environmental test results showed that lead and lid seal failures due to thermal stressing was only a problem with the hard glass (Ceramic) body DIP utilizing a metal lid and/or bottom. Insufficient failure data were generated for the other package types tested to correlate test results with the package ranking.
Impact of bone lead and bone resorption on plasma and whole blood lead levels during pregnancy.
Téllez-Rojo, Martha María; Hernández-Avila, Mauricio; Lamadrid-Figueroa, Héctor; Smith, Donald; Hernández-Cadena, Leticia; Mercado, Adriana; Aro, Antonio; Schwartz, Joel; Hu, Howard
2004-10-01
The authors tested the hypotheses that maternal bone lead burden is associated with increasing maternal whole blood and plasma lead levels over the course of pregnancy and that this association is modified by rates of maternal bone resorption. A total of 193 Mexican women were evaluated (1997-1999) in the first, second, and third trimesters of pregnancy. Whole blood lead and plasma lead levels were measured in each trimester. Urine was analyzed for cross-linked N-telopeptides (NTx) of type I collagen, a biomarker of bone resorption. Patella and tibia lead levels were measured at 4 weeks postpartum. The relation between whole blood, plasma, and bone lead and NTx was assessed using mixed models. Plasma lead concentrations followed a U-shape, while NTx levels increased significantly during pregnancy. In a multivariate model, the authors observed a significant and positive interaction between NTx and bone lead when plasma lead was used as the outcome variable. Dietary calcium intake was inversely associated with plasma lead. Results for whole blood lead were similar but less pronounced. These results confirm previous evidence that bone resorption increases during pregnancy, with a consequential significant release of lead from bone, constituting an endogenous source of prenatal exposure. They also provide a rationale for testing strategies (e.g., nutritional supplementation with calcium) aimed at decreasing prenatal lead exposure.
Certification and Career Success: A LEADS Project
ERIC Educational Resources Information Center
Russ-Eft, Darlene; Dickison, Phil; Levine, Roger
2008-01-01
This study examines the relationship between certification examination test results and Emergency Medical Technician (EMT) career success. The sample was drawn from the Longitudinal Emergency Medical Technician Attributes and Demographics Study (LEADS). LEADS participants were matched with National Registry of Emergency Medical Technician (NREMT)…
TAB interconnects for space concentrator solar cell arrays
NASA Technical Reports Server (NTRS)
Avery, J.; Bauman, J. S.; Gallagher, P.; Yerkes, J. W.
1993-01-01
The Boeing Company has evaluated the use of Tape Automated Bonding (TAB) and Surface Mount Technology (SMT) for a highly reliable, low cost interconnect for concentrator solar cell arrays. TAB and SMT are currently used in the electronics industry for chip interconnects and printed circuit board assembly. TAB tape consists of sixty-four 3-mil/1-oz tin-plated copper leads on 8-mil centers. The leads are thermocompression gang bonded to GaAs concentrator solar cell with silver contacts. This bond, known as an Inner Lead Bond (ILB), allows for pretesting and sorting capability via nondestruct wire bond pull and flash testing. Destructive wire pull tests resulted in preferred mid-span failures. Improvements in fill factor were attributed to decreased contact resistance on TAB bonded cells. Preliminary thermal cycling and aging tests were shown excellent bond strength and metallurgical results. Auger scans of bond sites reveals an Ag-Cu-Tin composition. Improper bonds are identified through flash testing as a performance degradation. On going testing of cells are underway at Lewis Research Center. SMT techniques are utilized to excise and form TAB leads post ILB. The formed leads' shape isolates thermal mismatches between the cells and the flex circuit they are mounted on. TABed cells are picked and placed with a gantry x-y-z positioning system with pattern recognition. Adhesives are selected to avoid thermal expansion mismatch and promote thermal transfer to the flex circuit. TAB outer lead bonds are parallel gap welded (PGW) to the flex circuit to finish the concentrator solar cell subassembly.
Lead exposure and rate of change in cognitive function in older women
Power, Melinda C; Korrick, Susan; Tchetgen Tchetgen, Eric J; Nie, Linda H; Grodstein, Francine; Hu, Howard; Weuve, Jennifer; Schwartz, Joel; Weisskopf, Marc G
2014-01-01
Background Higher long-term cumulative lead exposure predicts faster cognitive decline in older men, but evidence of an association in women is lacking. Objective To determine if there is an association between lead exposure and cognitive decline in women. Methods This study considers a sample of 584 women from the Nurses’ Health Study who live in or near Boston, Massachusetts. We quantified lead exposure using biomarkers of lead exposure assessed in 1993–2004 and evaluated cognitive decline by repeated performance on a telephone battery of cognitive tests primarily assessing learning, memory, executive function, and attention completed in 1995–2008. All cognitive test scores were z-transformed for use in analyses. We used linear mixed models with random effects to quantify the association between each lead biomarker and change in cognition overall and on each individual test. Results Consideration of individual tests showed greater cognitive decline with increased tibia lead concentrations, a measure of long-term cumulative exposure, for story memory and category fluency. The estimated excess annual decline in overall cognitive test z-score per SD increase in tibia bone lead concentration was suggestive, although the confidence intervals included the null (0.024 standard units, 95% confidence interval: −0.053 , 0.004 – an additional decline in function equivalent to being 0.33 years older). We found little support for associations between cognitive decline and patella or blood lead, which provide integrated measures of exposure over shorter timeframes. Conclusions Long-term cumulative lead exposure may be weakly associated with faster cognitive decline in community-dwelling women, at least in some cognitive domains. PMID:24529005
Fabrication and Testing of a Leading-Edge-Shaped Heat Pipe
NASA Technical Reports Server (NTRS)
Glass, David E.; Merrigan, Michael A.; Sena, J. Tom; Reid, Robert S.
1998-01-01
The development of a refractory-composite/heat-pipe-cooled leading edge has evolved from the design stage to the fabrication and testing of a full size, leading-edge-shaped heat pipe. The heat pipe had a 'D-shaped' cross section and was fabricated from arc cast Mo-4lRe. An artery was included in the wick. Several issues were resolved with the fabrication of the sharp leading edge radius heat pipe. The heat pipe was tested in a vacuum chamber at Los Alamos National Laboratory using induction heating and was started up from the frozen state several times. However, design temperatures and heat fluxes were not obtained due to premature failure of the heat pipe resulting from electrical discharge between the induction heating apparatus and the heat pipe. Though a testing anomaly caused premature failure of the heat pipe, successful startup and operation of the heat pipe was demonstrated.
Lead paint removal with high-intensity light pulses.
Grapperhaus, Michael J; Schaefer, Raymond B
2006-12-15
This paper presents the results of an initial investigation into using high-intensity incoherent light pulses to strip paint. Measurements of light pulse characteristics, the reflectivity of different paints and initial experiments on the threshold for paint removal, and paint removal are presented, along with an approximate model consistent with experimental results. Paint removal tests include lead paint, the reduction of lead levels to below levels required for lead abatement, as well as air and light emissions measurements that are within regulatory guidelines.
Effects of Lead Poisoning on Cognitive Test Performance.
ERIC Educational Resources Information Center
Krall, Vita; And Others
1980-01-01
Forty-seven lead poisoned children, treated and without encephalopathy, were compared with sibling controls on perceptual-verbal pattern comparisons of subtests of the Wechsler Intelligence Scale for Children (WISC) to determine whether there was brain damage. Results indicated that lead poisoning, treated, and without encephalopathy, does not…
Boracchi, Michele; Andreola, Salvatore; Collini, Federica; Gentile, Guendalina; Maciocco, Francesca; Maghin, Francesca; Zoja, Riccardo
2017-08-01
Histochemical determination of lead in gunshot residues (GSR) raises the question of possible environmental contamination by heavy metals. Authors assess the specificity of the Sodium Rhodizonate Test in the search of lead derived from environmental pollution. Sodium Rhodizonate Test and 5% HCl Sodium Rhodizonate test were applied to skin samples taken from two groups of victims, whose cause of death was not related to gunshot wounds: group A included 25 corpses found in open spaces after a long time; group B included 16 corpses exhumed after a period of 11 years. The use of these histochemical tests to skin samples from these two groups did not show metal debris histochemically similar to the lead present in GSR. These tests were confirmed to be specific in highlighting the GSR coming from gunshot, without being affected by the potential environmental contamination of the heavy metal pollutants, coming from air or soil. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA-DoD Lower Process Temperature Lead-Free Solder Project Overview
NASA Technical Reports Server (NTRS)
Kessel, Kurt R.
2014-01-01
This project is a follow-on effort to the Joint Council on Aging AircraftJoint Group on Pollution Prevention (JCAAJG-PP) Pb-free Solder Project and NASA-DoD Lead-Free Electronics Project which were the first projects to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community. This effort would continue to build on the results from the JCAAJG-PP Lead-Free Solder Project and NASA-DoD Lead-Free Electronics Project while focusing on a particular failure mechanism currently plaguing Pb-free assemblies, pad cratering.The NASA-DoD Lead-Free Electronics Project confirmed that pad cratering is one of the dominant failure modes that occur in various board level reliability tests, especially under dynamic loading. Pad Cratering is a latent defect that may occur during assembly, rework, and post assembly handling and testing.
Sutton, R; Fröhlig, G; de Voogt, W G; Goethals, M; Hintringer, F; Kennergren, C; Scanu, P; Guilleman, D; Treese, N; Hartung, W M; Stammwitz, E; Muetstege, A
2004-11-01
This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment of the stimulus pulse) between atrial and ventricular leads. In addition, significant differences were observed among various lead models with respect to changes over time in the initial ventricular PPA. Successful PPA reduction was defined as a reduction of the PPA below 0.5 mV for atrial leads and below 1 mV for ventricular leads. Results show a success rate for ventricular and atrial PPA reduction of 97.8% and 98.7%, respectively. Threshold tests showed that after reduction of the PPA loss of ventricular capture can be reliably detected. However, atrial threshold tests showed many false positive evoked response detections. In addition, unexpectedly high evoked response amplitudes were observed in the atrium after reduction of the PPA. Results from additional measurements suggest that these high atrial evoked response amplitudes come from the influence of the input filter of the pacemaker.
NASA Technical Reports Server (NTRS)
Handschuh, Katherine M.; Miller, Sandi G.; Sinnott, Matthew J.; Kohlman, Lee W.; Roberts, Gary D.; Pereira, J. Michael; Ruggeri, Charles R.
2014-01-01
Application of polymer matrix composite materials for jet engine fan blades is becoming attractive as an alternative to metallic blades; particularly for large engines where significant weight savings are recognized on moving to a composite structure. However, the weight benefit of the composite of is offset by a reduction of aerodynamic efficiency resulting from a necessary increase in blade thickness; relative to the titanium blades. Blade dimensions are largely driven by resistance to damage on bird strike. Further development of the composite material is necessary to allow composite blade designs to approximate the dimensions of a metallic fan blade. The reduction in thickness over the state of the art composite blades is expected to translate into structural weight reduction, improved aerodynamic efficiency, and therefore reduced fuel consumption. This paper presents test article design, subcomponent blade leading edge fabrication, test method development, and initial results from ballistic impact of a gelatin projectile on the leading edge of composite fan blades. The simplified test article geometry was developed to realistically simulate a blade leading edge while decreasing fabrication complexity. Impact data is presented on baseline composite blades and toughened blades; where a considerable improvement to impact resistance was recorded.
NASA Technical Reports Server (NTRS)
Miller, Sandi G.; Handschuh, Katherine; Sinnott, Matthew J.; Kohlman, Lee W.; Roberts, Gary D.; Martin, Richard E.; Ruggeri, Charles R.; Pereira, J. Michael
2015-01-01
Application of polymer matrix composite materials for jet engine fan blades is becoming attractive as an alternative to metallic blades; particularly for large engines where significant weight savings are recognized on moving to a composite structure. However, the weight benefit of the composite is offset by a reduction of aerodynamic efficiency resulting from a necessary increase in blade thickness; relative to the titanium blades. Blade dimensions are largely driven by resistance to damage on bird strike. Further development of the composite material is necessary to allow composite blade designs to approximate the dimensions of a metallic fan blade. The reduction in thickness over the state of the art composite blades is expected to translate into structural weight reduction, improved aerodynamic efficiency, and therefore reduced fuel consumption. This paper presents test article design, subcomponent blade leading edge fabrication, test method development, and initial results from ballistic impact of a gelatin projectile on the leading edge of composite fan blades. The simplified test article geometry was developed to realistically simulate a blade leading edge while decreasing fabrication complexity. Impact data is presented on baseline composite blades and toughened blades; where a considerable improvement to impact resistance was recorded.
NASA Technical Reports Server (NTRS)
Keller, Donald F.; Sandford, Maynard C.; Pinkerton, Theresa L.
1991-01-01
An experimental and analytical investigation was initiated to determine the effects of planform curvature (curving the leading and trailing edges of a wing in the X-Y plane) on the transonic flutter characteristics of a series of three moderately swept wing models. Experimental flutter results were obtained in the Langley Transonic Dynamics Tunnel for Mach numbers from 0.60-1.00, with air as the test medium. The models were semispan cantilevered wings with a 3 percent biconvex airfoil and a panel aspect ratio of 1.14. The baseline model had straight leading and trailing edges (i.e., no planform curvature). The radii of curvature of the leading edges for these two models were 200 and 80 inches. The radii of curvature of the leading edges of the other two models were determined so that the root and tip chords were identical for all three models. Experimental results showed that flutter-speed index and flutter frequency ratio increased as planform curvature increase (radius of curvature of the leading edge was decreased) over the test range of Mach numbers. Analytical flutter results were calculated with a subsonic flutter-prediction program, and they agreed well with the experimental results.
Lead poisoning from homemade wine: a case study.
Mangas, S; Visvanathan, R; van Alphen, M
2001-01-01
A 66-year-old man suffered the symptoms of severe lead poisoning for 2 years before diagnosis. The man had a blood lead level (PbB) on admission to hospital of 98 microg/dL. A detailed investigation revealed that the poisoning occurred as a result of drinking a homemade red wine, for which analyses showed a lead concentration up to 14 mg/L--70 times the Australian maximum limit for lead in wine. The source of the lead was a highly corroded enamel bathtub in which grape crushings and juice were stored for a week prior to bottling. The corrosion of the enamel surface of the bathtub had resulted in pitted patches up to 1 mm in depth along the side of the bathtub. Powdering of the tub surface was evident below a level where wine had been in contact with the sides of the tub. The homemade wine had a pH of 3.8, which would have greatly contributed to the solubilization of metals from the glaze. We conducted a test in which commercial red wine of similar pH and containing < 0.2 mg/L lead was placed in this tub for 7 days. Subsequent testing revealed a lead level of 310 mg/L. This high lead concentration is consistent with the surface area of enamel on the bathtub being in contact with a small liquid volume as in the case of the leaching test using commercial red wine. This case study highlights the importance of the use of food-grade materials for the preparation and storage of homemade beverages or food. PMID:11335194
Lead poisoning from homemade wine: a case study.
Mangas, S; Visvanathan, R; van Alphen, M
2001-04-01
A 66-year-old man suffered the symptoms of severe lead poisoning for 2 years before diagnosis. The man had a blood lead level (PbB) on admission to hospital of 98 microg/dL. A detailed investigation revealed that the poisoning occurred as a result of drinking a homemade red wine, for which analyses showed a lead concentration up to 14 mg/L--70 times the Australian maximum limit for lead in wine. The source of the lead was a highly corroded enamel bathtub in which grape crushings and juice were stored for a week prior to bottling. The corrosion of the enamel surface of the bathtub had resulted in pitted patches up to 1 mm in depth along the side of the bathtub. Powdering of the tub surface was evident below a level where wine had been in contact with the sides of the tub. The homemade wine had a pH of 3.8, which would have greatly contributed to the solubilization of metals from the glaze. We conducted a test in which commercial red wine of similar pH and containing < 0.2 mg/L lead was placed in this tub for 7 days. Subsequent testing revealed a lead level of 310 mg/L. This high lead concentration is consistent with the surface area of enamel on the bathtub being in contact with a small liquid volume as in the case of the leaching test using commercial red wine. This case study highlights the importance of the use of food-grade materials for the preparation and storage of homemade beverages or food.
Sabbar, M; Delaville, C; De Deurwaerdère, P; Benazzouz, A; Lakhdar-Ghazal, N
2012-05-17
Lead intoxication has been suggested as a high risk factor for the development of Parkinson disease. However, its impact on motor and nonmotor functions and the mechanism by which it can be involved in the disease are still unclear. In the present study, we studied the effects of lead intoxication on the following: (1) locomotor activity using an open field actimeter and motor coordination using the rotarod test, (2) anxiety behavior using the elevated plus maze, (3) "depression-like" behavior using sucrose preference test, and (4) subthalamic nucleus (STN) neuronal activity using extracellular single unit recordings. Male Sprague-Dawley rats were treated once a day with lead acetate or sodium acetate (20 mg/kg/d i.p.) during 3 weeks. The tissue content of monoamines was used to determine alteration of these systems at the end of experiments. Results show that lead significantly reduced exploratory activity, locomotor activity and the time spent on the rotarod bar. Furthermore, lead induced anxiety but not "depressive-like" behavior. The electrophysiological results show that lead altered the discharge pattern of STN neurons with an increase in the number of bursting and irregular cells without affecting the firing rate. Moreover, lead intoxication resulted in a decrease of tissue noradrenaline content without any change in the levels of dopamine and serotonin. Together, these results show for the first time that lead intoxication resulted in motor and nonmotor behavioral changes paralleled by noradrenaline depletion and changes in the firing activity of STN neurons, providing evidence consistent with the induction of atypical parkinsonian-like deficits. Copyright © 2012 IBRO. Published by Elsevier Ltd. All rights reserved.
Lead oxide as used in lead acid storage batteries, part two
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orsino, J.A.
1986-06-01
Without oxide controls, the battery manufacturing business can become one of the most confusing and frustrating experiences known. Inexplicable things happen during mixing, pasting and assembly, and testing, in the laboratory or in the field becomes an unhappy event. Almost any oxide of sufficient purity can be processed to make a good battery, but the characteristics must be known to be able to process it right, and once the process has been established, the oxide must be uniformly made to make the resulting batteries uniformly good. Fortunately, the tests required to assure uniformity are few, and simple to perform. Assumingmore » pure pig lead from primary sources or from carefully refined secondary sources, three tests can tell the whole story. These tests are described.« less
Misleading biochemical laboratory test results
Nanji, Amin A.
1984-01-01
This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845
Lead-acid batteries in micro-hybrid applications. Part II. Test proposal
NASA Astrophysics Data System (ADS)
Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.
In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.
Quadriplegia due to lead-contaminated opium--case report.
Beigmohammadi, Mohammad Taghi; Aghdashi, Moosa; Najafi, Atabak; Mojtahedzadeh, Mojtaba; Karvandian, Kassra
2008-10-01
Utilization of lead-contaminated opium may lead to severe motor neuron impairment and quadriplegia. Forty years oriented old male, opium addict, was admitted to the ICU, with headache, nausea and abdominal pain, and weakness in his lower and upper extremities without definitive diagnosis. The past medical and occupational history was negative. Laboratory investigation showed; anemia (Hb 7.7 g/dl), slightly elevated liver function tests, elevated total bilirubin, and ESR. Abdominal sonography and brain CT scan were normal. EMG and NCV results and neurologic examination were suggestive for Guillain-Barre. He underwent five sessions of plasmapheresis. Blood lead level was > 200 microg/dl. He received dimercaprol (BAL) and calcium disodium edetate (CaEDTA) for two five days session. Upon discharge from ICU all laboratory tests were normal and blood lead level was reduced, but he was quadriplegic. The delayed treatment of lead poisoning may lead to irreversible motor neuron defect.
[A Case of Lead Poisoning with Drug-induced Liver Injury after Ingestion of Herbal Medicine].
Jeon, Gi Jung; Park, Jong Ha; Kim, Min Sung; Yu, Jong Won; Park, Jae Hyun; Kim, Min Sik
2015-06-01
A 61-year-old male patient was admitted because of unexplained abdominal pain and anemia. His past medical history was unremarkable except for having taken herbal medicine to treat facial palsy two months ago. The result of health examination performed about a month ago showed increased serum aspartate and alanine aminotransferase level, and he was diagnosed with toxic hepatitis by herbal medicine. When the patient presented to the outpatient department three weeks ago, follow-up liver function test results showed improvement but he complained of abdominal pain. Despite extensive blood chemistry tests and computed tomography, the cause of pain could not be found. After much deliberation, serum lead level and herbal medicines analysis was performed based on the fact that he took herbal medicine two months ago, and he could finally be diagnosed with lead poisoning. Since the serum lead level was high enough to be indicated for lead chelating therapy, conservative management was given. When a patient with toxic hepatitis due to herbal medication presents with abdominal pain, the possibility of lead poisoning should always be taken into consideration.
Feasibility of a portable X-ray fluorescence device for bone lead measurements of condor bones.
Specht, Aaron J; Parish, Chris N; Wallens, Emma K; Watson, Rick T; Nie, Linda H; Weisskopf, Marc G
2018-02-15
Lead based ammunition is a primary source of lead exposure, especially for scavenging wildlife. Lead poisoning remains the leading cause of diagnosed death for the critically endangered California condors, which are annually monitored via blood tests for lead exposure. The results of these tests are helpful in determining recent exposure in condors and in defining the potential for exposure to other species including humans. Since condors are victim to acute and chronic lead exposure, being able to measure both would lend valuable information on the rates of exposure and accumulation through time. A commercial portable X-ray fluorescence (XRF) device has been optimized to measure bone lead in vivo in humans, but this device could also be valuable for field measurements of bone lead in avian species. In this study, we performed measurements of bone Pb in excised, bare condor bones using inductively coupled plasma mass spectrometry (ICP-MS), a cadmium 109 (Cd-109) K-shell X-ray fluorescence (KXRF) system, and a portable XRF system. Both KXRF and portable XRF bone Pb measurement techniques demonstrated good correlations with ICP-MS results (r=0.93 and r=0.92 respectively), even with increasing skin thickness (r=0.86 between ICP-MS and portable XRF at 1.54mm of soft tissue). In conclusion, our results suggest that a portable XRF could be a useful option for measurement of bone Pb in avian species in the field. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Camarda, Charles J.; Glass, David E.
1992-01-01
Heat pipes have been considered for use on wing leading edge for over 20 years. Early concepts envisioned metal heat pipes cooling a metallic leading edge. Several superalloy/sodium heat pipes were fabricated and successfully tested for wing leading edge cooling. Results of radiant heat and aerothermal testing indicate the feasibility of using heat pipes to cool the stagnation region of shuttle-type space transportation systems. The test model withstood a total seven radiant heating tests, eight aerothermal tests, and twenty-seven supplemental radiant heating tests. Cold-wall heating rates ranged from 21 to 57 Btu/sq ft-s and maximum operating temperatures ranged from 1090 to 1520 F. Follow-on studies investigated the application of heat pipes to cool the stagnation regions of single-stage-to-orbit and advanced shuttle vehicles. Results of those studies indicate that a 'D-shaped' structural design can reduce the mass of the heat-pipe concept by over 44 percent compared to a circular heat-pipe geometry. Simple analytical models for heat-pipe startup from the frozen state (working fluid initially frozen) were adequate to approximate transient, startup, and steady-state heat-pipe performance. Improvement in analysis methods has resulted in the development of a finite-element analysis technique to predict heat-pipe startup from the frozen state. However, current requirements of light-weight design and reliability suggest that metallic heat pipes embedded in a refractory composite material should be used. This concept is the concept presently being evaluated for NASP. A refractory-composite/heat-pipe-cooled wing leading edge is currently being considered for the National Aero-Space Plane (NASP). This concept uses high-temperature refractory-metal/lithium heat pipes embedded within a refractory-composite structure and is significantly lighter than an actively cooled wing leading edge because it eliminates the need for active cooling during ascent and descent. Since the NASP vehicle uses cryogenic hydrogen to cool structural components and then burns this fuel in the combustor, hydrogen necessary for descent cooling only, when the vehicle is unpowered, is considered to be a weight penalty. Details of the design of the refractory-composite/heat-pipe-cooled wing leading edge are currently being investigated. Issues such as thermal contact resistance and thermal stress are also being investigated.
NASA Astrophysics Data System (ADS)
Camarda, Charles J.; Glass, David E.
1992-10-01
Heat pipes have been considered for use on wing leading edge for over 20 years. Early concepts envisioned metal heat pipes cooling a metallic leading edge. Several superalloy/sodium heat pipes were fabricated and successfully tested for wing leading edge cooling. Results of radiant heat and aerothermal testing indicate the feasibility of using heat pipes to cool the stagnation region of shuttle-type space transportation systems. The test model withstood a total seven radiant heating tests, eight aerothermal tests, and twenty-seven supplemental radiant heating tests. Cold-wall heating rates ranged from 21 to 57 Btu/sq ft-s and maximum operating temperatures ranged from 1090 to 1520 F. Follow-on studies investigated the application of heat pipes to cool the stagnation regions of single-stage-to-orbit and advanced shuttle vehicles. Results of those studies indicate that a 'D-shaped' structural design can reduce the mass of the heat-pipe concept by over 44 percent compared to a circular heat-pipe geometry. Simple analytical models for heat-pipe startup from the frozen state (working fluid initially frozen) were adequate to approximate transient, startup, and steady-state heat-pipe performance. Improvement in analysis methods has resulted in the development of a finite-element analysis technique to predict heat-pipe startup from the frozen state. However, current requirements of light-weight design and reliability suggest that metallic heat pipes embedded in a refractory composite material should be used. This concept is the concept presently being evaluated for NASP. A refractory-composite/heat-pipe-cooled wing leading edge is currently being considered for the National Aero-Space Plane (NASP). This concept uses high-temperature refractory-metal/lithium heat pipes embedded within a refractory-composite structure and is significantly lighter than an actively cooled wing leading edge because it eliminates the need for active cooling during ascent and descent. Since the NASP vehicle uses cryogenic hydrogen to cool structural components and then burns this fuel in the combustor, hydrogen necessary for descent cooling only, when the vehicle is unpowered, is considered to be a weight penalty. Details of the design of the refractory-composite/heat-pipe-cooled wing leading edge are currently being investigated. Issues such as thermal contact resistance and thermal stress are also being investigated.
A new material for removing heavy metals from water
NASA Technical Reports Server (NTRS)
Philipp, Warren H., Jr.; Street, Kenneth W., Jr.
1994-01-01
The NASA Lewis Research Center developed and is patenting a new high capacity ion exchange material (IEM) that removes toxic metals from contaminated water in laboratory tests. The IEM can be made into many forms, such as thin films, coatings, pellets, and fibers. As a result, it can be adapted to many applications to purify contaminated water wherever it is found, be it in waste water treatment systems, lakes, ponds, industrial plants, or in homes. Laboratory tests have been conducted on aqueous solutions containing only one of the following metal cations: lead, copper, mercury, cadmium, silver, chromium (III), nickel, zinc, and yttrium. Tests were also conducted with: (1) calcium present to determine its effects on the uptake of cadmium and copper, and (2) uranium and lanthanides which are stand-ins for other radioactive elements, (3) drinking water for the removal of copper and lead, and (3) others compositions. The results revealed that the IEM removes all these cations, even in the presence of the calcium. Of particular interest are the results of the tests with the drinking water: the lead concentration was reduced from 142 ppb down to 2.8 ppb (well below the accepted EPA standard).
Removal of lead by apatite and its stability in the presence of organic acids.
Katoh, Masahiko; Makimura, Akihiko; Sato, Takeshi
2016-12-01
In this study, lead sorption and desorption tests were conducted with apatite and organic acids (i.e. citric, malic, and formic acids) to understand lead removal by apatite in the presence of an organic acid and lead dissolution from the lead- and organic-acid-sorbed apatite by such organic acid exposure. The lead sorption test showed that the amount of lead removed by apatite in the presence of organic acid varied depending on the type of acid used. The molar amounts of calcium dissolved from apatite in the presence and absence of organic acid were exactly the same as those of lead removed even under different pH conditions as well as different organic acid concentrations, indicating that the varying amount of lead removal in the presence of different organic acids resulted from the magnitude of the dissolution of apatite and the precipitation of lead phosphate minerals. The percentages of lead dissolved from the organic-acid-sorbed and non-organic-acid-sorbed apatite by all the organic acid extractions were equal and higher than those by water extraction. In particular, the highest extractions were observed in the non-organic-acid-sorbed apatite by citric and malic acids. These results suggest that to immobilize lead by the use of apatite in the presence of organic acids, much more apatite must be added than in the absence of organic acid, and that measures must be taken to ensure that the immobilized lead is not dissolved.
Optimization of batteries for plug-in hybrid electric vehicles
NASA Astrophysics Data System (ADS)
English, Jeffrey Robb
This thesis presents a method to quickly determine the optimal battery for an electric vehicle given a set of vehicle characteristics and desired performance metrics. The model is based on four independent design variables: cell count, cell capacity, state-of-charge window, and battery chemistry. Performance is measured in seven categories: cost, all-electric range, maximum speed, acceleration, battery lifetime, lifetime greenhouse gas emissions, and charging time. The performance of each battery is weighted according to a user-defined objective function to determine its overall fitness. The model is informed by a series of battery tests performed on scaled-down battery samples. Seven battery chemistries were tested for capacity at different discharge rates, maximum output power at different charge levels, and performance in a real-world automotive duty cycle. The results of these tests enable a prediction of the performance of the battery in an automobile. Testing was performed at both room temperature and low temperature to investigate the effects of battery temperature on operation. The testing highlighted differences in behavior between lithium, nickel, and lead based batteries. Battery performance decreased with temperature across all samples with the largest effect on nickel-based chemistries. Output power also decreased with lead acid batteries being the least affected by temperature. Lithium-ion batteries were found to be highly efficient (>95%) under a vehicular duty cycle; nickel and lead batteries have greater losses. Low temperatures hindered battery performance and resulted in accelerated failure in several samples. Lead acid, lead tin, and lithium nickel alloy batteries were unable to complete the low temperature testing regime without losing significant capacity and power capability. This is a concern for their applicability in electric vehicles intended for cold climates which have to maintain battery temperature during long periods of inactivity. Three sample optimizations were performed: a compact car, a, truck, and a sports car. The compact car benefits from increased battery capacity despite the associated higher cost. The truck returned the smallest possible battery of each chemistry, indicating that electrification is not advisable. The sports car optimization resulted in the largest possible battery, indicating large performance from increased electrification. These results mirror the current state of the electric vehicle market.
... loss, which leads to weight loss Depression Fever Exams and Tests Lab tests alone can't diagnose PMR. Most people with this condition have high markers of inflammation, such as the sedimentation rate ( ESR ) and C-reactive protein. Other test results for this condition ...
HSCT Ref-H Transonic Flap Data Base: Wind-Tunnel Test and Comparison with Theory
NASA Technical Reports Server (NTRS)
Vijgen, Paul M.
1999-01-01
In cooperation with personnel from the Boeing ANP Laboratory and NASA Langley, a performance test was conducted using the Reference-H 1.675% model ("NASA Modular Model") without nacelles at the NASA Langley 16-Ft Transonic Tunnel. The main objective of the test was to determine the drag reduction achievable with leading-edge and trailing-edge flaps deflected along the outboard wing span at transonic Mach numbers (M = 0.9 to 1.2) for purpose of preliminary design and for comparison with computational predictions. The obtained drag data with flap deflections for Mach numbers of 1.07 to 1.20 are unique for the Reference H wing. Four leading-edge and two trailing-edge flap deflection angles were tested at a mean-wing chord-Reynolds number of about 5.7 million. An outboard-wing leading-edge flap deflection of 81 provides a 4.5 percent drag reduction at M = 1.2 A = 0.2), and much larger values at lower Mach numbers with larger flap deflections. The present results for the baseline (no flaps deflected) compare reasonably well with previous Boeing and NASA Ref-H tunnel tests, including high-Reynolds number NTF results. Viscous CFD simulations using the OVERFLOW thin-layer N.S. method properly predict the observed trend in drag reduction at M = 1.2 as function of leading-edge flap deflection. Modified linear theory properly predicts the flap effects on drag at subsonic conditions (Aero2S code), and properly predicts the absolute drag for the 40 and 80 leading-edge deflection at M = 1.2 (A389 code).
Current methodological issues in the economic assessment of personalized medicine.
Annemans, Lieven; Redekop, Ken; Payne, Katherine
2013-01-01
There is a need for methodological scrutiny in the economic assessment of personalized medicine. In this article, we present a list of 10 specific issues that we argue pose specific methodological challenges that require careful consideration when designing and conducting robust model-based economic evaluations in the context of personalized medicine. Key issues are related to the correct framing of the research question, interpretation of test results, data collection of medical management options after obtaining test results, and expressing the value of tests. The need to formulate the research question clearly and be explicit and specific about the technology being evaluated is essential because various test kits can have the same purpose and yet differ in predictive value, costs, and relevance to practice and patient populations. The correct reporting of sensitivity/specificity, and especially the false negatives and false positives (which are population dependent), of the investigated tests is also considered as a key element. This requires additional structural complexity to establish the relationship between the test result and the consecutive treatment changes and outcomes. This process involves translating the test characteristics into clinical utility, and therefore outlining the clinical and economic consequences of true and false positives and true and false negatives. Information on treatment patterns and on their costs and outcomes, however, is often lacking, especially for false-positive and false-negative test results. The analysis can even become very complex if different tests are combined or sequentially used. This potential complexity can be handled by explicitly showing how these tests are going to be used in practice and then working with the combined sensitivities and specificities of the tests. Each of these issues leads to a higher degree of uncertainty in economic models designed to assess the added value of personalized medicine compared with their simple pharmaceutical counterparts. To some extent, these problems can be overcome by performing early population-level simulations, which can lead to the identification and collection of data on critical input parameters. Finally, it is important to understand that a test strategy does not necessarily lead to more quality-adjusted life-years (QALYs). It is possible that the test will lead to not only fewer QALYs but also fewer costs, which can be defined as "decremental" cost per QALYs. Different decision criteria are needed to interpret such results. © 2013 Published by Elsevier Inc. on behalf of International Society for Pharmacoeconomics and Outcomes Research (ISPOR).
Are There Dangerous Levels of Lead in Local Soil?
NASA Astrophysics Data System (ADS)
Pita, I.
2017-12-01
The purpose of this experiment was to show that comparing random soil samples from areas in New Orleans; the Garden District will have the highest levels of lead in soil. My Independent variable was the soil samples collected from locations in the Garden District area of New Orleans, and other locations throughout New Orleans. The control was the soil samples collected from the local playground in the New Orleans area. My dependent variable was the lead soil test kit, using ppm (parts per million) of lead to show concentration. 400 ppm + in bare soil where children play is considered dangerous hazard levels. 1,000 + ppm in all other areas is considered dangerous hazard levels. The first step to my experiment, I collected soil samples from different locations throughout the Garden District area of New Orleans. The second step to my experiment, I conducted the lead soil testing in a controlled area at home in a well ventilated room, using all the necessary safety equipment needed, I began testing a 24 hour test period and a 48 hour test period. I then collected the data from both test. The results showed that soil samples from the Garden District area compared to the other sample locations had higher lead concentrations in the soil. This backed my hypothesis when comparing soil samples from areas in New Orleans, the Garden District will have the highest lead levels. In conclusion these experiments showed that with the soil samples collected, there were higher concentrations of lead in the soil from the Garden District area compared to the other areas where soil was collected. Reconstruction and renovations, from the devastation that Hurricane Katrina created, are evident of the lead in paint of older homes which now show the lead concentration in the soil. Lead is a lethal element if consumed or inhaled in high doses, which can damage key organs in our body, which can be deadly. Better awareness through social media, television, radio, doctors, studies, pamphlets, environmental agencies, and other forms to address the steps in protecting your family and home for a lead free environment.
Lead-acid batteries in solar photovoltaic power systems for marine aids to navigation. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trenchard, S.E.
1981-10-01
Since 1974, the U.S. Coast Guard has been testing lead-acid batteries in solar photovoltaic-powered systems for aids to navigation. Three types of lead-acid batteries, distinguished by the composition of their grid material, have been tested: lead-antimony grid, lead-calcium grid, and pure-lead grid. This report contains a comparison of the charging characteristics and the charge-discharge cycling behavior of each grid type. All types were remarkably similar qualitatively in their daily as well as annual cycling behavior but the significance of the quantitative differences offer distinctive tradeoffs. This report presents models for water usage, depth-of-discharge, and post-cycle capacity for various levels ofmore » voltage regulation. Based on the post-cycle capacity tests, the effect of grid strength, grid thickness, and operating conditions on life expectancy are presented. A final discussion presents the results of a field deployment of solar photovoltaic-powered aids to navigation in the Miami, Florida area. Potential solutions to the battery terminal corrosion and bird guano problems observed are discussed.« less
Exposure assessment of JAVELIN missile combustion products
NASA Astrophysics Data System (ADS)
Lundy, Donald O.; Langford, Roland E.
1994-02-01
Characterization and analysis of combustion products resulting from firing the JAVELIN missile were performed. Of those combustion products analyzed, it was determined that airborne lead concentrations exceeded the OSHA PEL of 50 micrograms each time the missile was fired while in the enclosure. Since the OSHA PEL standard is based upon a continuous rather than a short-term exposures blood lead concentrations were sought to ascertain the relationship between a short duration airborne exposure and its physiological effect on the body. Blood lead levels were taken on 49 test subjects prior to various JAVELIN missile test firings. Of those 49, 21 were outfitted With personal sampling equipment to determine airborne concentrations at the Assistant Gunner and Gunner positions. Periodic blood sampling after a single exposure showed an average increase of 2.27 micrograms/dL for all test subjects. Recommendations were made to consider changes in the positioning of the enclosure inhabitants to minimize airborne lead concentrations, to limit the number of missiles fired (situation dependent), and replacement of the lead B-resorcyolate with a non-lead containing burn rate modifier for the launch motor.
Advanced lead acid battery development project. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-02-01
This project involved laboratory and road testing of the Horizon (registered) advanced lead acid batteries produced by Electrosource, Inc. A variety of electric vehicles in the fleet operated by the Sacramento Municipal Utility District and McClellan Air Force Base were used for road tests. The project was sponsored by the Defense Advanced Research Projects Agency under RA 93-23 entitled Electric Vehicle Technology and Infrastructure. The Horizon battery is a valve regulated, or sealed, lead acid battery produced in a variety of sizes and performance levels. During the project, several design and process improvements on the Horizon battery resulted in amore » production battery with a specific energy approaching 45 watt-hours per kilogram (Whr/kg) capable of delivering a peak current of 450 amps. The 12 volt, 95 amp-hour (Ahr) Horizon battery, model number 12N95, was placed into service in seven (7) test vehicles, including sedans, prototype lightweight electric vehicles, and passenger vans. Over 20,000 miles have been driven to date on vehicles powered by the Horizon battery. Road test results indicate that when the battery pack is used with a compatible charger and charge management system, noticeably improved acceleration characteristics are evident, and the vehicles provide a useful range almost 20% greater than with conventional lead-acid batteries.« less
NASA Technical Reports Server (NTRS)
Mann, M. J.; Huffman, J. K.; Fox, C. H., Jr.; Campbell, R. L.
1983-01-01
Wind tunnel tests were conducted to examine the use of wing leading-edge devices for improved subsonic and transonic maneuver performance. These devices were tested on a fighter configuration which utilized supercritical-wing technology. The configuration had a leading-edge sweep of 45 deg and an aspect ratio of 3.28. The tests were conducted at Mach numbers of 0.60 and 0.85 with angles of attack from -0.5 deg to 22 deg. At both Mach numbers, sharp leading-edge flaps produced vortices which greatly altered the flow pattern on the wing and resulted in substantial reductions in drag at high lift. Underwing or pylon-type vortex generators also reduced drag at high lift. The vortex generators worked better at a Mach number of 0.60. The vortex generators gave the best overall results with zero toe-in angle and when mounted on either the outboard part of the wing or at both an outboard location and halfway out the semispan. Both the flaps and the vortex generators had a minor effect on the pitching moment. Fluorescent minitufts were found to be useful for flow visualization at transonic maneuver conditions.
Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.
Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil
2016-11-01
Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lead exposure among automobile radiator repair workers and their children in New York City.
Nunez, C M; Klitzman, S; Goodman, A
1993-05-01
Despite a comprehensive Occupational Safety and Health Administration lead standard, exposure to lead continues in many industries. This paper describes a blood lead screening and education program for automobile radiator repair workers and their families in New York City. Results showed that 67% of automobile radiator repair workers (n = 62) in 89% of the shops tested (n = 24) had blood lead levels in excess of 25 micrograms/dl. The vast majority of workers had never been tested previously, and none had received health and safety training regarding occupational lead exposure. Although none of the workers' children's blood lead levels were in excess of then-current guidelines, several had levels which may be associated with subclinical toxicity and in excess of the revised Centers for Disease Control guidelines of 10 micrograms/dl. This project demonstrates that lead exposure in the automotive radiator repair industry continues to be widespread and that local health departments can assist in hazard identification and remediation.
The Effects of Group Monitoring on Fatigue-Related Einstellung during Mathematical Problem Solving
ERIC Educational Resources Information Center
Frings, Daniel
2011-01-01
Fatigue resulting from sleep deficit can lead to decreased performance in a variety of cognitive domains and can result in potentially serious accidents. The present study aimed to test whether fatigue leads to increased Einstellung (low levels of cognitive flexibility) in a series of mathematical problem-solving tasks. Many situations involving…
... a pH, carbon dioxide/oxygen, or electrolyte imbalance. Examples include uncontrolled diabetes , which can lead to ketoacidosis ... acid from the stomach), and sodium bicarbonate overdose. Examples of test results associated with the above conditions ...
Lead induced oxidative DNA damage in battery-recycling child workers from Bangladesh.
Arif, Mohammad; Islam, Mm Towhidul; Shekhar, Hossain Uddin
2018-04-01
Lead exposure can damage cells directly by effecting DNA or indirectly by modifying proteins and enzymes. In Bangladesh, many working children are exposed to a very high level of lead during their early life due to their involvement with lead-oriented professions. This imposes a severe threat to the growth and development of the children. Therefore to study the effect of lead, we enrolled 60 age-matched male children, from an area of old Dhaka city, where battery-recycling shops are located, depending on their blood lead concentration. If the children had a plasma lead concentration above the WHO recommended threshold level of 10 µg/dl, we grouped them as test subjects and others as control subjects to determine the effect of lead on different biochemical parameters of the body. Compared to the controls, acculumlation of the lipid peroxidation product, malondialdehyde, increased significantly in test subjects ( p < 0.01). Lead exposure also increased the protein carbonyl content ( p < 0.05) and significantly decreased the plasma glutathione levels of test subjects compared to the controls ( p < 0.05). While comparing the lead-exposed group against controls, it was found that the percentage of damaged DNA, as measured using the Comet assay, significantly increased in tail ( p < 0.01) and decreased in head regions. All of these results suggest that high-plasma lead content may induce an oxidative stress to the study population, which may lead to DNA damage.
Structural Health Monitoring Analysis for the Orbiter Wing Leading Edge
NASA Technical Reports Server (NTRS)
Yap, Keng C.
2010-01-01
This viewgraph presentation reviews Structural Health Monitoring Analysis for the Orbiter Wing Leading Edge. The Wing Leading Edge Impact Detection System (WLE IDS) and the Impact Analysis Process are also described to monitor WLE debris threats. The contents include: 1) Risk Management via SHM; 2) Hardware Overview; 3) Instrumentation; 4) Sensor Configuration; 5) Debris Hazard Monitoring; 6) Ascent Response Summary; 7) Response Signal; 8) Distribution of Flight Indications; 9) Probabilistic Risk Analysis (PRA); 10) Model Correlation; 11) Impact Tests; 12) Wing Leading Edge Modeling; 13) Ascent Debris PRA Results; and 14) MM/OD PRA Results.
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false External corrosion control: Test leads. 192.471... Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive. (b) Each test lead wire must be...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false External corrosion control: Test leads. 192.471... Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive. (b) Each test lead wire must be...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false External corrosion control: Test leads. 192.471... Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive. (b) Each test lead wire must be...
Leaching assessment of road materials containing primary lead and zinc slags.
Barna, R; Moszkowicz, P; Gervais, C
2004-01-01
Characterisation of the leaching behaviour of waste-containing materials is a crucial step in the environmental assessment for reuse scenarios. In our research we applied the multi-step European methodology ENV 12-920 to the leaching assessment of road materials containing metallurgical slag. A Zn slag from an imperial smelting furnace (ISF) and a Pb slag from a lead blast furnace (LBF) are investigated. The two slags contain up to 11.2 wt% of lead and 3.5 wt% of zinc and were introduced as a partial substitute for sand in two road materials, namely sand-cement and sand-bitumen. At the laboratory scale, a leaching assessment was performed first through batch equilibrium leaching tests. Second, the release rate of the contaminants was evaluated using saturated leaching tests on monolithic material. Third, laboratory tests were conducted on monolithic samples under intermittent wetting conditions. Pilot-scale tests were conducted for field testing of intermittent wetting conditions. The results show that the release of Pb and Zn from the materials in a saturated scenario was controlled by the pH of the leachates. For the intermittent wetting conditions, an additional factor, blocking of the pores by precipitation during the drying phase is proposed. Pilot-scale leaching behaviour only partially matched with the laboratory-scale test results: new mass transfer mechanisms and adapted laboratory leaching tests are discussed.
Jerez Ch, José A; Romero, Rosaura M
2016-11-01
Landfill leachates containing heavy metals are important contaminants and a matter of great concern due to the effect that they might have on ecosystems. We evaluated the use of Cajanus cajan to remove chromium and lead from landfill leachates. Eight-week-old plants were submitted to varied tests to select the experimental conditions. Water assays with a solution (pH 6) containing leachate (25% v/v) were selected; the metals were added as potassium dichromate and lead (II) nitrate salts. Soil matrices that contained leachate (30% v/v) up to field capacity were used. For both water and soil assays, the metal concentrations were 10 mg kg(-1). C. cajan proved able to remove 49% of chromium and 36% of lead, both from dilute leachate. The plants also removed 34.7% of chromium from irrigated soil, but were unable to decrease the lead content. Removal of nitrogen from landfill leachate was also tested, resulting in elimination of 85% of ammonia and 70% of combined nitrite/nitrate species. The results indicate that C. cajan might be an effective candidate for the rhizofiltration of leachates containing chromium and lead, and nitrogen in large concentrations.
Primary Prevention of Lead Exposure: The Philadelphia Lead Safe Homes Study
Campbell, Carla; Tran, Mary; Gracely, Edward; Starkey, Naomi; Kersten, Hans; Palermo, Peter; Rothman, Nancy; Line, Laura; Hansen-Turton, Tine
2011-01-01
Objective Lead exposure in children can lead to neuropsychological impairment. This study tested whether primary prevention interventions in the newborn period prevent elevated blood lead levels (BLLs). Methods The Philadelphia Lead Safe Homes (LSH) Study offered parental education, home evaluation, and lead remediation to the families of urban newborns. Households were randomized to a standard lead education group or maintenance education group. We conducted home visits at baseline, six months, and 12 months. To compare BLLs, we identified a matched comparison group. Results We enrolled and randomized 314 newborns in the intervention component; 110 completed the study. There were few significant differences between the randomized groups. In the combined intervention groups, positive results on visual inspection declined from baseline to 12 months (97.0% to 90.6%, p=0.007). At baseline, 36.9% of homes were above the U.S. Environmental Protection Agency's lead dust standard, compared with 26.9% at 12 months (p=0.032), mainly due to a drop in windowsill dust levels. Both groups showed a significant increase in parental scores on a lead education test. Children in the intervention and matched control groups had similar geometric mean initial BLLs (2.6 vs. 2.7, p=0.477), but a significantly higher percentage of children in the intervention group had an initial blood lead screening compared with those in the matched group (88.9% vs. 84.4%, p=0.032). Conclusions A study of primary prevention of lead exposure showed a higher blood lead screening rate for the combined intervention groups and mean BLLs at one year of age not statistically different from the comparison group. Most homes had lead hazards. Lead education significantly increased knowledge. PMID:21563715
HIFiRE-5 Flight Test Preliminary Results (Postprint)
2013-11-01
DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test article leading edge...Reference System (DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test...pitch angle relative to earth as measured by IMU , or flight-path elevation angle as measured by GPS or IMU , degrees = body-fixed angular coordinate
Removing lead in drinking water with activated carbon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, R.M.; Kuennen, R.W.
A point-of-use (POU) granular activated carbon (GAC) fixed bed adsorber (FBA) was evaluated for reduction of soluble and insoluble lead from drinking water. Some of the factors which affect lead removal by GAC were evaluated, such as carbon type, solution pH, and a limited amount of work on competitive interactions. The design criteria for lead reduction by a POU device are also addressed. Minicolumns were used to evaluate the capacity of carbon for lead under a variety of conditions. The importance of surface chemistry of the carbon and the relationship with the pH of the water for lead reduction wasmore » demonstrated. Results indicate that a properly designed POU-GAC-FBA can reduce lead in drinking water to below the EPA action level of 15 ppb while being tested under a variety of conditions as specified under the National Sanitation Foundation (NSF) International Standard 53 test protocol. 37 refs., 9 figs., 1 tab.« less
SiC/SiC Leading Edge Turbine Airfoil Tested Under Simulated Gas Turbine Conditions
NASA Technical Reports Server (NTRS)
Robinson, R. Craig; Hatton, Kenneth S.
1999-01-01
Silicon-based ceramics have been proposed as component materials for use in gas turbine engine hot-sections. A high pressure burner rig was used to expose both a baseline metal airfoil and ceramic matrix composite leading edge airfoil to typical gas turbine conditions to comparatively evaluate the material response at high temperatures. To eliminate many of the concerns related to an entirely ceramic, rotating airfoil, this study has focused on equipping a stationary metal airfoil with a ceramic leading edge insert to demonstrate the feasibility and benefits of such a configuration. Here, the idea was to allow the SiC/SiC composite to be integrated as the airfoil's leading edge, operating in a "free-floating" or unrestrained manner. and provide temperature relief to the metal blade underneath. The test included cycling the airfoils between simulated idle, lift, and cruise flight conditions. In addition, the airfoils were air-cooled, uniquely instrumented, and exposed to the same internal and external conditions, which included gas temperatures in excess of 1370 C (2500 F). Results show the leading edge insert remained structurally intact after 200 simulated flight cycles with only a slightly oxidized surface. The instrumentation clearly suggested a significant reduction (approximately 600 F) in internal metal temperatures as a result of the ceramic leading edge. The object of this testing was to validate the design and analysis done by Materials Research and Design of Rosemont, PA and to determine the feasibility of this design for the intended application.
NASA-DoD Lead-Free Electronics Project
NASA Technical Reports Server (NTRS)
Kessel, Kurt
2010-01-01
This slide presentation reviews the current state of the lead-free electronics project. It characterizes the test articles, which were built with lead-free solder and lead-free component finishes. The tests performed and reported on are: thermal cycling, combine environments testing, mechanical shock testing, vibration testing and drop testing.
TESTING AND ANALYSES OF CHAT AND ASPHALT-CONTAINING CHAT
Granular mine waste are generated from the extraction and beneficiation of lead/zinc minerals. The fine gravel waste, commonly known as chat, in the Tristate Mining District contains elevated levels of lead, zinc and cadmium which can result in potentially serious human health a...
Joint Lead-Free Solder Test Program for High Reliability Military and Space Applications
NASA Technical Reports Server (NTRS)
Brown, Christina
2004-01-01
Current and future space and defense systems face potential risks from the continued use of tin-lead solder, including: compliance with current environmental regulations, concerns about potential environmental legislation banning lead-containing products, reduced mission readiness, and component obsolescence with lead surface finishes. For example, the United States Environmental Protection Agency (USEPA) has lowered the Toxic Chemical Release reporting threshold for lead to 100 pounds. Overseas, the Waste Electrical and Electronic Equipment (WEEE) and the Restriction on Hazardous Substances (RoHS) Dicctives in Europe and similar mandates in Japan have instilled concern that a legislative body will prohibit the use of lead in aerospace/military electronics soldering. Any potential banning of lead compounds could reduce the supplier base and adversely affect the readiness of missions led by the National Aeronautics and Space Administration (NASA) and the U.S. Department of Defense (DoD). Before considering lead-free electronics for system upgrades or future designs, however, it is important for the DoD and NASA to know whether lead-free solders can meet their systems' requirements. No single lead-free solder is likely to qualify for all defense and space applications. Therefore, it is important to validate alternative solders for discrete applications. As a result of the need for comprehensive test data on the reliability of lead-free solders, a partnership was formed between the DoD, NASA, and several original equipment manufactures (OEMs) to conduct solder-joint reliability (laboratory) testing of three lead-free solder alloys on newly manufactured and reworked circuit cards to generate performance data for high-reliability (IPC Class 3) applications.
Characteristics of lead induced stress corrosion cracking of alloy 690 in high temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, K.K.; Lim, J.K.; Watanabe, Yutaka
1996-10-01
Slow strain rate tests (SSRT) were conducted on alloy 690 in various lead chloride solutions and metal lead added to 100 ppm chloride solution at 288 C. The corrosion potential (rest potential) for the alloy was measured with SSRT tests. The cracking was observed by metallographic examination and electron probe micro analyzer. Also, the corrosion behavior of the alloy was evaluated by anodic polarized measurement at 30 C. Resulting from the tests, cracking was characterized by cracking behavior, crack length and crack growth rate, and lead effects on cracking. The cracking was mainly intergranular in mode, approximately from 60 ummore » to 450 um in crack length, and approximately 10{sup {minus}6} to 10{sup {minus}7} mmS-1 in crack velocity. The cracking was evaluated through the variation the corrosion potential in potential-time and lead behavior during SSRTs. The lead effect in corrosion was evaluated through active to passive transition behavior in anodic polarized curves. The corrosion reactions in the cracking region were confirmed by electron probe microanalysis. Alloy 690 is used for steam generation tubes in pressurized water reactors.« less
NASA Technical Reports Server (NTRS)
Dicarlo, Daniel J.; Brown, Philip W.; Hallissy, James B.
1992-01-01
Flight tests of an F-106B aircraft equipped with a leading-edge vortex flap, which represented the culmination of a research effort to examine the effectiveness of the flap, were conducted at the NASA Langley Research Center. The purpose of the flight tests was to establish a data base on the use of a wing leading-edge vortex flap as a means to validate the design and analysis methods associated with the development of such a vortical flow-control concept. The overall experiment included: refinements of the design codes for vortex flaps; numerous wind tunnel entries to aid in verifying design codes and determining basic aerodynamic characteristics; design and fabrication of the flaps, structural modifications to the wing tip and leading edges of the test aircraft; development and installation of an aircraft research instrumentation system, including wing and flap surface pressure measurements and selected structural loads measurements; ground-based simulation to assess flying qualities; and finally, flight testing. This paper reviews the operational aspects associated with the flight experiment, which includes a description of modifications to the research airplane, the overall flight test procedures, and problems encountered. Selected research results are also presented to illustrate the accomplishments of the research effort.
Spanwise visualization of the flow around a three-dimensional foil with leading edge protuberances
NASA Astrophysics Data System (ADS)
Stanway, M. J.; Techet, A. H.
2006-11-01
Studies of model humpback whale fins have shown that leading edge protuberances, or tubercles, can lead to delayed stall and increased lift at higher angles of attack, compared to foils with geometrically smooth leading edges. Such enhanced performance characteristics could prove highly useful in underwater vehicles such as gliders or long range AUVs (autonomous underwater vehicles). In this work, Particle Imaging Velocimetry (PIV) is performed on two static wings in a water tunnel over a range of angles of attack. These three- dimensional, finite-aspect ratio wings are modeled after a humpback whale flipper and are identical in shape, tapered from root to tip, except for the leading edge. In one of the foils the leading edge is smooth, whereas in the other, regularly spaced leading edge bumps are machined to simulate the whale’s fin tubercles. Results from these PIV tests reveal distinct cells where coherent flow structures are destroyed as a result of the leading edge perturbations. Tests are performed at Reynolds numbers Re ˜ O(10^5), based on chordlength, in a recirculating water tunnel. An inline six-axis load cell is mounted to measure the forces on the foil over a range of static pitch angles. It is hypothesized that this spanwise breakup of coherent vortical structures is responsible for the delayed angle of stall. These quantitative experiments complement exiting qualitative studies with two dimensional foils.
Translating theory into practice: results of a 2-year trial for the LEAD programme.
Shelton, D
2008-05-01
This paper presents data for 2 years of a continuing study aimed to reduce the risk of first-time involvement by minority youth with the juvenile justice system. A quasi-experimental design was used to test a 14-week expressive art curriculum (LEAD: leadership, education, achievement and development) implemented in two rural communities. A total of 70 African American youth participated in the programme over a 2-year period. Pre- and post-test differences were examined for protective factors, behavioural self-control, self-esteem and resilience measures. When compared with the after-school programme (control group), youth in the LEAD programme in both communities had more dramatic increases in post-test scores following the intervention. The combined data from year 1 and year 2 provide positive findings in support of LEAD as a prevention programme for young offenders. The placement of the programme within an African American church in year 2 improved the processes of the LEAD programme and seemed to provide a better fit with the original design of the programme, highlighting the importance of the context, in which the programme was provided.
Rossi, Enrico; McLaughlin, Virginia; Joseph, John; Bulsara, Max; Coleman, Kerryn; Douglas, Charles; Robertson, Andrew
2012-04-01
To assess the impact of airborne lead dust on blood lead levels in residents of Esperance, a regional Western Australian town, with particular reference to preschool children. Following identification of significant airborne lead contamination, residents were notified that a blood lead clinic was available to all, with testing of preschool children encouraged. About 40% (333 children) of the preschool group and about 20% of the remaining population were tested. The main measures were blood lead levels, prevalence of elevated results and comparisons to other Western Australian surveys. In preschoolers, 2.1% (seven children) had blood lead levels exceeding the current 10 μg/dL level of concern. This was not significantly different to two previous community-based surveys elsewhere in Western Australia. However, at a lower cut-off of 5 μg/dL, the prevalence of elevated lead levels was 24.6%, significantly higher than children tested in a previous Western Australian survey. The prevalence of blood lead levels of 10 μg/dL or greater in adults was 1.3% (26 adults), not significantly different from a previous Western Australian survey. The prevalence of preschool children with blood lead levels exceeding the current level of concern was not significantly increased. However, the increased prevalence of children with lead levels at or above 5 μg/dL demonstrates exposure to lead dust pollution. This episode of lead dust contamination highlights the need for strict adherence to environmental controls and effective monitoring processes to ensure the prevention of future events. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craswell, P.W.; Price, J.; Boyle, P.D.
EDTA (calcium disodium edetate) lead mobilization and x-ray fluorescence (XRF) finger bone lead tests were done in 42 patients with chronic renal failure and without persisting lead intoxication. Nineteen of 23 patients with gout and 8 of 19 without gout had positive EDTA lead mobilization tests. Those patients with gout excreted significantly more excess lead chelate than those without gout. In the gout group 17 patients denied any childhood or industrial exposure to lead. They had a greater number of positive tests and excreted significantly more excess lead chelate than 14 patients with neither gout nor lead exposure. These resultsmore » confirm that gout in the presence of chronic renal failure is a useful marker of chronic lead poisoning. Of 27 patients with positive lead mobilization tests, only 13 had elevated XRF finger bone lead concentrations (sensitivity 48%). Three of 15 patients with negative lead mobilization tests had elevated XRF finger bone lead concentrations (specificity 80%). Although the XRF finger bone lead test is a convenient noninvasive addition to the diagnostic evaluation of patients with chronic renal failure and gout, its application is limited due to the lack of sensitivity of the method.« less
Experimental investigation of leading-edge thrust at supersonic speeds
NASA Technical Reports Server (NTRS)
Wood, R. M.; Miller, D. S.
1983-01-01
Wings, designed for leading edge thrust at supersonic speeds, were investigated in the Unitary Plan Wind Tunnel at Mach numbers of 1.60, 1.80, 2.00, 2.16, and 2.36. Experimental data were obtained on a uncambered wing which had three interchangeable leading edges that varied from sharp to blunt. The leading edge thrust concept was evaluated. Results from the investigation showed that leading edge flow separation characteristics of all wings tested agree well with theoretical predictions. The experimental data showed that significant changes in wing leading edge bluntness did not affect the zero lift drag of the uncambered wings.
Analysis of EUVE Experiment Results
NASA Technical Reports Server (NTRS)
Horan, Stephen
1996-01-01
A series of tests to validate an antenna pointing concept for spin-stabilized satellites using a data relay satellite are described. These tests show that proper antenna pointing on an inertially-stabilized spacecraft can lead to significant access time through the relay satellite even without active antenna pointing. We summarize the test results, the simulations to model the effects of antenna pattern and space loss, and the expected contact times. We also show how antenna beam width affects the results.
NASA Astrophysics Data System (ADS)
Berg, H. P.; Pfaff, K.; Hennecke, D. K.
The resultant effects on the cooling effectiveness at the leading edge area of an impingement-cooled turbine vane by varying certain geometrical parameters is described with reference to local internal heat transfer coefficients determined from experiment and temperature calculations. The local heat transfer on the cooling-air side is determined experimentally with the aid of the analogy between heat- and mass transfer. The impingement cooling is provided from an inserted sheet-metal containing a single row of holes. The Reynolds Number and several of the cooling geometry parameters were varied. The results demonstrate the high local resolution of the method of measurement, which allows improved analytical treatment of the leading-edge cooling configuration. These experiments also point to the necessity of not always performing model tests under idealized conditions. This becomes very clear in the case of the tests performed on an application-oriented impingement-cooling configuration like that often encountered in engine manufacture. In conclusion, as an example, temperature calculations are employed to demonstrate the effect on the cooling effectiveness of varying the distances between insert and inner surface of the leading edge. It shows how the effectiveness of the leading edge cooling can be increased by simple geometrical measures, which results in a considerable improvement in service life.
NASA Technical Reports Server (NTRS)
Koven, William; Graham, Robert R
1948-01-01
Results are presented of an investigation in the Langley 19-foot pressure tunnel of the longitudinal characteristics of a semispan model wing having 37 degrees sweepback of the leading edge, an aspect ratio of 6, and NACA 641-212 airfoil section perpendicular to the 27-percent-chord line. Several types of stall-control devices including extensible round-nose leading-edge flaps, a leading-edge slat, and a drooped leading edge were investigated; partial- and full-span trailing-edge split and double slotted flaps were also tested. In addition, various combinations of the aforementioned leading- and trailing-edge flaps were investigated. The tests covered a range of Reynolds numbers between 2.00 x 10(6) and 9.35 x 10(6). The wing with or without trailing-edge splity of double slotted flap was longitudinally unstable near maximum lift due to tip stalling. The addition of an outboard half-span leading-edge flap or a leading-edge slat to the plain wing or wing with inboard half-span split flaps eliminated tip stalling and resulted in stable moment variations at the stall. The drooped leading edge, on the other hand, was only effective when used in conjunction with an upper-surface fence. The combination of an outboard leading-edge device and inboard half-span double slotted flap resulted in an undesirable loop in the pitching-moment curve near maximum lift in spite of an inboard stall. The loop is attributed to the section characteristics of the double slotted flap. Air-flow surveys behind the wing indicated that a suitably placed horizontal tail would eliminate the loop in the moment curve.
Mod-2 wind turbine project assessment and cluster test plans
NASA Technical Reports Server (NTRS)
Gordon, L. H.
1982-01-01
An assessment of the Mod-2 Wind Turbine project is presented based on initial goals and present results. Specifically, the Mod-2 background, project flow, and a chronology of events/results leading to Mod-2 acceptance is presented. After checkout/acceptance of the three operating turbines, NASA/LeRC will continue management of a two year test program performed at the DOE Goodnoe Hills test site. This test program is expected to yield data necessary for the continued development and optimization of wind energy systems. These test activities, the implementation of, and the results to date are also presented.
TESTING AND ANALYSES OF CHAT AND ASPHALT-CONTAINING CHAT (PRESENTATION)
Granular mine waste are generated from the extraction and beneficiation of lead/zinc minerals. The fine gravel waste, commonly known as chat, in the Tristate Mining District contains elevated levels of lead, zinc and cadmium which can result in potentially serious human health a...
Improvements and Performance of the Fermilab Solenoid Test Facility
Orris, Darryl; Arnold, Don; Brandt, Jeffrey; ...
2017-06-01
Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also providesmore » helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.« less
Improvements and Performance of the Fermilab Solenoid Test Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orris, Darryl; Arnold, Don; Brandt, Jeffrey
Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also providesmore » helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.« less
ERIC Educational Resources Information Center
Norris, John M.
2015-01-01
Traditions of statistical significance testing in second language (L2) quantitative research are strongly entrenched in how researchers design studies, select analyses, and interpret results. However, statistical significance tests using "p" values are commonly misinterpreted by researchers, reviewers, readers, and others, leading to…
Critical ionization velocity experiments in space
NASA Astrophysics Data System (ADS)
Lai, Shu T.; Murad, Edmond
1989-07-01
Space experiments to test the critical ionization velocity (CIV) theory have, on the whole, yielded negative results, with two notable exceptions. The results of all the experiments are analyzed with a view towards either optimizing or drawing conclusions about the conditions which lead to the propagation of CIV. In particular, four aspects of the conditions are considered: (1) beam injection angle with the ambient magnetic field in the ionosphere; (2) length of a CIV discharge region in a conical beam; (3) collisional ionization of the neutrals; and (4) chemiionization processes. The analysis leads to the conclusion that using the exhaust of the Shuttle engines may be the best way for testing CIV.
Precise Determination of the 1s Lamb Shift in Hydrogen-Like Lead and Gold Using Microcalorimeters
NASA Technical Reports Server (NTRS)
Kraft-Bermuth, S.; Andrianov, V.; Bleile, A.; Echler, A.; Egelhof, P.; Grabitz, P.; Ilieva, S.; Kiselev, O.; Kilbourne, C.; McCammon, D.;
2017-01-01
Quantum electrodynamics in very strong Coulomb fields is one scope which has not yet been tested experimentally with sufficient accuracy to really determine whether the perturbative approach is valid. One sensitive test is the determination of the 1s Lamb shift in highly-charged very heavy ions. The 1s Lamb shift of hydrogen-like lead (Pb81+) and gold (Au78+) has been determined using the novel detector concept of silicon microcalorimeters for the detection of hard x-rays. The results of (260 +/- 53) eV for lead and (211 +/- 42) eV for gold are within the error bars in good agreement with theoretical predictions. To our knowledge, for hydrogen-like lead, this represents the most accurate determination of the 1s Lamb shift.
Sobol, Nanna Aue; Hoffmann, Kristine; Vogel, Asmus; Lolk, Annette; Gottrup, Hanne; Høgh, Peter; Hasselbalch, Steen G; Beyer, Nina
2016-11-01
Alzheimer's disease (AD) causes a gradual decline in cognition, limitations of dual-tasking and physical function leading to total dependence. Hence, information about the interaction between physical function, dual-task performance and cognition may lead to new treatment strategies with the purpose of preserving function and quality of life. The objective of this study was to investigate the associations between physical function, dual-task performance and cognition in community-dwelling patients with mild AD. Baseline results from 185 participants (50-90 years old) in the single blinded multicenter RCT 'ADEX' (Alzheimer's disease: the effect of physical exercise) were used. Assessments included tests of physical function: 400-m walk test, 10-m walk test, Timed Up and Go test and 30-s chair stand test; dual-task performance, i.e., 10-m walk while counting backwards from 50 or naming the months backwards; and cognition, i.e., Mini Mental State Examination, Symbol Digit Modalities Test, the Stroop Color and Word Test, and Lexical verbal fluency test. Results in the 30-s chair stand test correlated significantly with all tests of cognition (r = .208-.242) while the other physical function tests only randomly correlated with tests of cognition. Results in the dual-task counting backwards correlated significantly with results in all tests of cognition (r = .259-.388), which accounted for 7%-15% of the variation indicating that a faster time to complete dual-task performance was associated with better cognitive performance. The evidence of the associations between physical function, dual-task performance and cognition is important when creating new rehabilitation interventions to patients with mild AD.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... the use of forms BSEE-0126 (Well Potential Test Report) and BSEE-0128 (Semiannual Well Test Report... the results of well tests to determine if reservoirs are being depleted in a manner that will lead to... burden Average number of annual responses hours (rounded) WELL TESTS/SURVEYS and CLASSIFYING RESERVOIRS...
Application of a flush airdata sensing system to a wing leading edge (LE-FADS)
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Czerniejewski, Mark W.; Nichols, Douglas A.
1993-01-01
This paper investigates the feasibility of locating a flush air-data sensing (FADS) system on a wing leading edge where the operation of the avionics or fire control radar system will not be hindered. The leading-edge FADS system (LE-FADS) was installed on an unswept symmetrical airfoil, and a series of low-speed wind-tunnel tests were conducted to evaluate the performance of the system. As a result of the tests it is concluded that the aerodynamic models formulated for use on aircraft nosetips are directly applicable to wing leading edges and that the calibration process is similar. Furthermore, the agreement between the air-data calculations for angle of attack and total pressure from the LE-FADS and known wind-tunnel values suggest that wing-based flush air-data systems can be calibrated to a high degree of accuracy. Static wind-tunnel tests for angles of attack from -50 to 50 deg and dynamic pressures from 3.6 to 11.4 lb/sq ft were performed.
Application of a Flush Airdata Sensing System to a Wing Leading Edge (LE-FADS)
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Czerniejewski, Mark W.; Nichols, Douglas A.
1993-01-01
The feasibility of locating a flush airdata sensing (FADS) system on a wing leading edge where the operation of the avionics or fire control radar system will not be hindered is investigated. The leading-edge FADS system (LE-FADS) was installed on an unswept symmetrical airfoil and a series of low-speed wind-tunnel tests were conducted to evaluate the performance of the system. As a result of the tests it is concluded that the aerodynamic models formulated for use on aircraft nosetips are directly applicable to wing leading edges and that the calibration process is similar. Furthermore, the agreement between the airdata calculations for angle of attack and total pressure from the LE-FADS and known wind-tunnel values suggest that wing-based flush airdata systems can be calibrated to a high degree of accuracy. Static wind-tunnel tests for angles of attack from -50 deg to 50 deg and dynamic pressures from 3.6 to 11.4 lb/sq ft were performed.
Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care.
Menon, Shailaja; Murphy, Daniel R; Singh, Hardeep; Meyer, Ashley N D; Sittig, Dean F
2016-01-01
Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Workarounds to manage EHR-based test results are common, and their use results from unmet provider information management needs. Future EHRs and the respective work systems around them need to evolve to meet these needs.
Development Program of Dual Mode Impact Delay Module for Artillery Fuzes.
1979-12-31
analysis phase to demonstrate design confidence and reliability of performance in the artillery firing environment. See Figure I for drawing of the latest...Device P/N KF88590 as proposed by us. This analysis will be based on results of penalty test« in which the test variables will include loading and...istently and unmistakably Dextrinated lead azide was, tent surrogate. On the basis of stab s Id be predicted that any system whi r mated lead azide
Performance characteristics of a laser initiated microdetonator
NASA Technical Reports Server (NTRS)
Yang, L. C.
1981-01-01
The test results of 320 units of a laser initiated microdetonator are summarized. The commercially fabricated units used a lead styphnate/lead azide/HMX (1 mg/13.5 mg) explosive train design contained in a miniature aluminum can that was capped with a glass-metal seal window. The test parameters were the laser energy, temperature, laser pulse duration, laser wavelength and nuclear radiation (5,000,000 rad of 1 MeV gamma rays). The performance parameters were the laser energy for ignition and the actuation response time.
When good news is bad news: psychological impact of false positive diagnosis of HIV.
Bhattacharya, Rahul; Barton, Simon; Catalan, Jose
2008-05-01
HIV testing is known to be stressful, however the impact of false positive HIV results on individuals is not well documented. This is a series of four case who developed psychological difficulties and psychiatric morbidities after being informed they had been misdiagnosed with HIV-positive status. We look into documented cases of misdiagnosis and potential risks of misdiagnosis. The case series highlights the implications a false diagnosis HIV-positive status can have, even when the diagnosis is rectified. Impact of misdiagnosis of HIV can lead to psychosocial difficulties and psychiatric morbidity, have public health and epidemiological implications and can lead to medico-legal conflict. This further reiterates the importance of HIV testing carried out ethically and sensitively, and in line with guidelines, respecting confidentiality and consent, and offering counselling pre-test and post-test, being mindful of the reality of erroneous and false positive HIV test results. The implications of misdiagnosis are for the individual, their partners and social contacts, as well as for the community.
NASA Astrophysics Data System (ADS)
Qi, Chenkun; Gao, Feng; Zhao, Xianchao; Wang, Qian; Ren, Anye
2018-06-01
On the ground the hardware-in-the-loop (HIL) simulation is a good approach to test the contact dynamics of spacecraft docking process in space. Unfortunately, due to the time delay in the system the HIL contact simulation becomes divergent. However, the traditional first-order phase lead compensation approach still result in a small divergence for the pure time delay. The serial Smith predictor and phase lead compensation approach proposed by the authors recently will lead to an over-compensation and an obvious convergence. In this study, a hybrid Smith predictor and phase lead compensation approach is proposed. The hybrid Smith predictor and phase lead compensation can achieve a higher simulation fidelity with a little convergence. The phase angle of the compensator is analyzed and the stability condition of the HIL simulation system is given. The effectiveness of the proposed compensation approach is tested by simulations on an undamped elastic contact process.
Thermodynamic Analysis of Oxygen-Enriched Direct Smelting of Jamesonite Concentrate
NASA Astrophysics Data System (ADS)
Zhang, Zhong-Tang; Dai, Xi; Zhang, Wen-Hai
2017-12-01
Thermodynamic analysis of oxygen-enriched direct smelting of jamesonite concentrate is reported in this article. First, the occurrence state of lead, antimony and other metallic elements in the smelting process was investigated theoretically. Then, the verification test was carried out. The results indicate that lead and antimony mainly exist in the alloy in the form of metallic lead and metallic antimony. Simultaneously, lead and antimony were also oxidized into the slag in the form of lead-antimony oxide. Iron and copper could be oxidized into the slag in the form of oxides in addition to combining with antimony in the alloy, while zinc was mainly oxidized into the slag in the form of zinc oxide. The verification test indicates that the main phases in the alloy contain metallic lead, metallic antimony and a small amount of Cu2Sb, FeSb2 intermetallic compounds, and the slag is mainly composed of kirschsteinite, fayalite and zinc oxide, in agreement with the thermodynamic analysis.
Lead poisoning in dogs: occurrence, source, clinical pathology, and electroencephalography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zook, B.C.; Carpenter, J.L.; Roberts, R.M.
1972-05-01
Accidental lead poisoning was diagnosed and studied in 236 dogs. The disease incidence increased annually after 1963 and was more common in Poodles and dogs less than 1 year old. The incidence was greatest in summer and early fall and was more common in dogs which dwelt in slum areas than was expected. Lead-based paints were the most frequent source of poisoning. Results of hematologic and urinary determinations supported those of previous studies. The diagnostic importance of nucleated and stippled red blood cells (RBC) in peripheral blood films was emphasized, and urine sediments frequently contained casts with few inflammatory cells.more » In addition, reticulocyte counts were usually increased and sedimentation rates and Coomb's test results were normal. Results of bone marrow studies indicated hyperplasia of, and partial maturation defect in, the erythrocytic series of most dogs. Determinations of various clinical chemistry tests and cerebrospinal fluid analysis were usually normal. Electroencephalographic changes consisted of irregular, generalized slow-wave activity of increased amplitude. 20 references, 5 figures, 12 tables.« less
The effects of work engagement and self-efficacy on personal initiative and performance.
Lisbona, Ana; Palaci, Francisco; Salanova, Marisa; Frese, Michael
2018-02-01
Two popular concepts, work engagement and personal initiative, are different but related constructs. This study is based on and extends the Frese and Fay (2001) model of personal initiative (PI) by including work engagement (WE) and self-efficacy as antecedents of PI, and performance as a consequence. Two studies (study 1, with a cross-sectional design using N = 396 participants from 22 organizations, and study 2, with a longitudinal design conducted in two waves with N = 118 participants from 15 organizations) test the hypotheses. Structural equation modeling and the PROCESS SPSS Macro were used to test the hypothesized mediating role of personal initiative in work engagement and performance, and the results show the indirect effect of WE on performance through PI. The results of these two studies confirmed our hypotheses: WE and self-efficacy lead to higher PI, which, in turn, leads to higher performance. In addition to considering WE as an antecedent of PI, the results lead to considering PI as an antecedent of performance.
[Blood cerebrospinal fluid barrier damage of rats induced by lead acetate or nano-lead exposure].
Feng, P P; Zhai, F J; Jiang, S F; Wu, J Z; Xue, L; Zheng, M M; Zhou, L L; Meng, C Y; Cao, M Y; Zhang, Y S
2016-05-20
To investigate the damage of blood-cerebrospinal fluid barrier (BCB) of rats induced by lead and nano-lead exposure in order to provide the basis for mechanism study of lead neurotoxicity. 39 male rats were randomly divided into control group, lead acetate exposed group and nano-lead exposed group. Rats in lead acetate exposed group and nano-lead exposed group were given 20 mg/kg lead acetate or nano-lead by oral gavage and rats in control groups were given the same amount saline for 9 weeks.Morris maze was used to test the learning function, serum albumin and CSF albumin were determined by ELISA. Confocal laser scanning microscope was applied to detect ZO-1 and Occludin protein expression in choroid plexus, real time-PCR was used to test the expression of ZO-1 and Occludin mRNA expression. Pathological changes of choroid plexus cells were observed by the electron microscopy. Compared with the control group, the escape latency of rats in lead acetate or nano-lead exposure group were longer and times of across platform were less. The levels of CSF albumin and the CSF albumin index in lead acetate or nano-lead exposed rats were obviously higher, and the fluorescence intensity of ZO-1, Occludin as well as mRNA expressions were lower than those in control group(P<0.05). Compared with lead acetate exposed group, the levels of CSF albumin and the CSF albumin index in nano-lead exposure group were higher. The fluorescence intensity and mRNA expressions of ZO-1, Occludin in nano-lead exposure group were than those in lead acetate group(P<0.05). Electron microscopy revealed that lead acetate or nano-lead exposure could induce shorter microvillus of choroid plexus epithelial cells, mitochondrion destruction and partial disconnection in intracellular junctions between two adjacent epithelial cells. Lead acetate and nano-lead exposed can result in the blood-cerebrospinal fluid barrier damage, which may involve in the process of lead induced neurotoxicity. Meanwhile, nano-lead exposure can induced in more worse damage in terms of blood-results in blood-cerebrospinal fluid barrier function.
Test results: Halon 1301 versus water sprinkler fire protection for essential electronic equipment
NASA Astrophysics Data System (ADS)
Reichelt, E. F.; Walker, J. L.; Vickers, R. N.; Kwan, A. J.
1982-07-01
This report describes results of testing two contending extinguishants, Halon 1301 and water, for fire protection of essential electronic equipment. A series of controlled fires in a facility housing an operational electronic data processing system sought to establish immediate and long term effects of exposure of sensitive electronic equipment and stored data to fire extinguishment atmospheres. Test results lead to the conclusion that Halon 1301 is superior to water as an extinguishant for fires occurring in essential electronic equipment installations.
Results of a Test and Win Contest to Raise Radon Awareness in Urban and Rural Settings
ERIC Educational Resources Information Center
Hahn, Ellen J.; Rayens, Mary Kay; Kercsmar, Sarah E.; Robertson, Heather; Adkins, Sarah M.
2014-01-01
Background: Radon is a leading cause of lung cancer, but few test their homes to determine radon levels. Purpose: The study assessed feasibility and success of a Test and Win Contest to promote radon testing in rural and urban communities. Methods: The prospective, quasi-experimental study tested a novel contest to raise radon awareness. Paid and…
Baker, Harolyn W.; Tufts, Margaret; Raymond, Randall E.; Salihu, Hamisu; Elliott, Michael R.
2013-01-01
Objectives. We assessed the long-term effect of early childhood lead exposure on academic achievement in mathematics, science, and reading among elementary and junior high school children. Methods. We linked early childhood blood lead testing surveillance data from the Detroit Department of Health and Wellness Promotion to educational testing data from the Detroit, Michigan, public schools. We used the linked data to investigate the effect of early childhood lead exposure on academic achievement among school-aged children, both marginally and adjusted for grade level, gender, race, language, maternal education, and socioeconomic status. Results. High blood lead levels before age 6 years were strongly associated with poor academic achievement in grades 3, 5, and 8. The odds of scoring less than proficient for those whose blood lead levels were greater than 10 micrograms per deciliter were more than twice the odds for those whose blood lead levels were less than 1 micrograms per deciliter after adjustment for potential confounders. Conclusions. Early childhood lead exposure was negatively associated with academic achievement in elementary and junior high school, after adjusting for key potential confounders. The control of lead poisoning should focus on primary prevention of lead exposure in children and development of special education programs for students with lead poisoning. PMID:23327265
NASA Astrophysics Data System (ADS)
Rimantho, Dino; Rahman, Tomy Abdul; Cahyadi, Bambang; Tina Hernawati, S.
2017-02-01
Calibration of instrumentation equipment in the pharmaceutical industry is an important activity to determine the true value of a measurement. Preliminary studies indicated that occur lead-time calibration resulted in disruption of production and laboratory activities. This study aimed to analyze the causes of lead-time calibration. Several methods used in this study such as, Six Sigma in order to determine the capability process of the calibration instrumentation of equipment. Furthermore, the method of brainstorming, Pareto diagrams, and Fishbone diagrams were used to identify and analyze the problems. Then, the method of Hierarchy Analytical Process (AHP) was used to create a hierarchical structure and prioritize problems. The results showed that the value of DPMO around 40769.23 which was equivalent to the level of sigma in calibration equipment approximately 3,24σ. This indicated the need for improvements in the calibration process. Furthermore, the determination of problem-solving strategies Lead Time Calibration such as, shortens the schedule preventive maintenance, increase the number of instrument Calibrators, and train personnel. Test results on the consistency of the whole matrix of pairwise comparisons and consistency test showed the value of hierarchy the CR below 0.1.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2016-01-01
AIM To describe our experience with shock testing for the evaluation of patients with Riata™ leads. METHODS Among 51 patients with normal baseline electrical parameters, 20 died during follow-up. Of the remaining 31 patients, 15 underwent the test: In 10 cases a defibrillation testing with ventricular fibrillation (VF) induction and in 5 cases a R-wave-synchronized shock (> 20 J, without inducing VF). The test was performed under sedation with Midazolam. RESULTS Twelve patients (80%) had a normal behavior during shock testing: In 8 cases induced VF was correctly detected and treated; in 4 cases of R-wave-synchronized shock electrical parameters remained stable and normal. Three patients (20%) failed the test. One patient with externalized conductors showed a sudden drop of high-voltage impedance (< 10 Ohm) after a 25 J R-wave-synchronized shock. Two other patients with externalized conductors, undergoing defibrillation testing, showed a short-circuit during shock delivery and the implantable cardioverter defibrillator was unable to interrupt VF. CONCLUSION In Riata™ leads the delivery of a low current during routine measurement of high-voltage impedance may not reveal a small short circuit, that can only be evident by attempting to deliver a true shock, either for spontaneous arrhythmias or in the context of a shock testing. PMID:27957252
NASA Technical Reports Server (NTRS)
White, E. R.
1982-01-01
Exploratory tests have been conducted in the NASA-Langley Research Center's 12-Foot Low-Speed wind Tunnel to evaluate the application of wing-leading-edge devices on the stall-departure and spin resistance characteristics of a 1/6-scale model of a T-tail general-aviation aircraft. The model was force tested with an internal strain-gauge balance to obtain aerodynamic data on the complete configuration and with a separate wing balance to obtain aerodynamic data on the outer portion of the wing. The addition of the outboard leading-edge droop eliminated the abrupt stall of the windtip and maintained or increased the resultant-force coefficient up to about alpha = 32 degrees. This change in slope of the resultant-force coefficient curve with angle of attack has been shown to be important for eliminating autorotation and for providing spin resistance.
The Risk Factors of Child Lead Poisoning in China: A Meta-Analysis
Li, You; Qin, Jian; Wei, Xiao; Li, Chunhong; Wang, Jian; Jiang, Meiyu; Liang, Xue; Xia, Tianlong; Zhang, Zhiyong
2016-01-01
Background: To investigate the risk factors of child lead poisoning in China. Methods: A document retrieval was performed using MeSH (Medical subject heading terms) and key words. The Newcastle-Ottawa Scale (NOS) was used to assess the quality of the studies, and the pooled odd ratios with a 95% confidence interval were used to identify the risk factors. We employed Review Manager 5.2 and Stata 10.0 to analyze the data. Heterogeneity was assessed by both the Chi-square and I2 tests, and publication bias was evaluated using a funnel plot and Egger’s test. Results: Thirty-four articles reporting 13,587 lead-poisoned children met the inclusion criteria. Unhealthy lifestyle and behaviors, environmental pollution around the home and potential for parents’ occupational exposure to lead were risk factors of child lead poisoning in the pooled analyses. Our assessments yielded no severe publication biases. Conclusions: Seventeen risk factors are associated with child lead poisoning, which can be used to identify high-risk children. Health education and promotion campaigns should be designed in order to minimize or prevent child lead poisoning in China. PMID:27005641
Results of electric-vehicle propulsion system performance on three lead-acid battery systems
NASA Technical Reports Server (NTRS)
Ewashinka, J. G.
1984-01-01
Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.
Results of electric-vehicle propulsion system performance on three lead-acid battery systems
NASA Technical Reports Server (NTRS)
Ewashinka, J. G.
1984-01-01
Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rose, David Martin; Schenkman, Benjamin L.; Borneo, Daniel R.
2013-08-01
The Department of Energy Office of Electricity (DOE/OE), Sandia National Laboratory (SNL) and the Base Camp Integration Lab (BCIL) partnered together to incorporate an energy storage system into a microgrid configured Forward Operating Base to reduce the fossil fuel consumption and to ultimately save lives. Energy storage vendors have supplied their systems to SNL Energy Storage Test Pad (ESTP) for functional testing and a subset of these systems were selected for performance evaluation at the BCIL. The technologies tested were electro-chemical energy storage systems comprised of lead acid, lithium-ion or zinc-bromide. MILSPRAY Military Technologies has developed an energy storage systemmore » that utilizes lead acid batteries to save fuel on a military microgrid. This report contains the testing results and some limited assessment of the Milspray Scorpion Energy Storage Device.« less
A novel method for direct solder bump pull testing using lead-free solders
NASA Astrophysics Data System (ADS)
Turner, Gregory Alan
This thesis focuses on the design, fabrication, and evaluation of a new method for testing the adhesion strength of lead-free solders, named the Isotraction Bump Pull method (IBP). In order to develop a direct solder joint-strength testing method that did not require customization for different solder types, bump sizes, specific equipment, or trial-and-error, a combination of two widely used and accepted standards was created. First, solder bumps were made from three types of lead free solder were generated on untreated copper PCB substrates using an in-house fabricated solder bump-on-demand generator, Following this, the newly developed method made use of a polymer epoxy to encapsulate the solder bumps that could then be tested under tension using a high precision universal vertical load machine. The tests produced repeatable and predictable results for each of the three alloys tested that were in agreement with the relative behavior of the same alloys using other testing methods in the literature. The median peak stress at failure for the three solders tested were 2020.52 psi, 940.57 psi, and 2781.0 psi, and were within one standard deviation of the of all data collected for each solder. The assumptions in this work that brittle fracture occurred through the Intermetallic Compound layer (IMC) were validated with the use of Energy-Dispersive X-Ray Spectrometry and high magnification of the fractured surface of both newly exposed sides of the test specimens. Following this, an examination of the process to apply the results from the tensile tests into standard material science equations for the fracture of the systems was performed..
Primary prevention of lead exposure--blood lead results at age two years.
Campbell, Carla; Gracely, Edward; Tran, Mary; Starkey, Naomi; Kersten, Hans; Palermo, Peter; Rothman, Nancy; Line, Laura; Hansen-Turton, Tine
2012-04-01
The Philadelphia Lead Safe Homes (LSH) Study was designed to evaluate whether educational and environmental interventions in the first year of life for families of newborns increased knowledge of lead exposure prevention and were associated with less elevation of blood lead levels (BLLs) for these children, when compared to children receiving standard care. The current study performed descriptive statistics on the second-year BLL data for both groups and compared these using chi-square tests for proportions and unpaired t-tests for means. A BLL result was found for 159 (50.6%) of the 314 LSH cohort children and 331 (52.7%) of the 628 control children (p = 0.1). Mean and standard deviation for age at draw was 23.8 (3.4) months versus 23.6 (3.1) months (P = 0.6). Geometric mean BLLs were 3.7 versus 3.5 µg/dL (P = 0.4). The percentages of the cohort group with a BLL of ≥ 20, ≥ 10 and ≥ 5 μg/dL, respectively, were 0.6%, 5% and 30%; for the controls 1.2%, 6.6%, and 25%. These percentages were not significantly different between groups. A comparison of geometric mean BLLs and percentages above several BLL cut points drawn at age two years in a group of urban newborns benefitting from study interventions versus a group of similar urban children did not yield statistically significant differences. Both groups had relatively lower lead levels when compared to historical cohort groups, which may reflect a continuing downward trend in BLLs in U.S. children. The interventions did result in benefits to the families such as an increase in parental knowledge about lead exposure prevention and in-home wet cleaning activity, and a decrease in lead dust levels in study homes.
Laboratory testing of the (Japan Storage Battery) traction batteries GS E75A and GS E150H
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report describes the testing of the GS E75A and GS E150H flooded lead-acid 12-volt traction batteries and compares the selected batteries to U.S.-made electric vehicle batteries. The results and conclusions of the testing are presented.
ERIC Educational Resources Information Center
Porter, Kristin E.
2018-01-01
Researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple testing procedures (MTPs) are statistical…
Test Preparation in New Jersey: Inquiry-Oriented and Didactic Responses
ERIC Educational Resources Information Center
Firestone, William A.; Monfils, Lora; Schorr, Roberta Y.
2004-01-01
As testing becomes more prevalent as a policy tool in the Anglo-Saxon world, debates continue as to whether it supports central reforms of instruction or leads to a kind of 'teaching to the test' that invalidates results and undermines more challenging instruction. This paper reports on a three-year study of mathematics testing of nine-year-olds…
ERIC Educational Resources Information Center
Matthews, Dona; Foster, Joanne
2014-01-01
Embarking on the standardized testing process often leads parents of gifted children to other questions about intelligence, tests, and assessment practices. What is intelligence? Do IQ tests measure it? Are there better ways of deciding who needs gifted programming? What can parents request by way of results and their interpretation? Should…
Occupational health surveillance strategies for an ethnically diverse Asian employee population.
Sakamoto, M; Vaughan, J; Tobias, B
2001-05-01
1. Implementation of a medical/health surveillance program can prevent the damaging effects of lead toxicity. Lead toxicity may be a result of acute or chronic exposure and can affect the hematopoietic, nervous, renal, and reproductive systems. 2. Minority groups tend to be overrepresented in lead industries. Further, an increase in high lead levels can be compounded by cultural influences. Education must be geared toward the specific employee populations. 3. Successful programs require assistance from all team members--occupational health nurse, safety engineer, industrial hygienist, and environmental engineer. Occupational health nurses play an important role in implementation of medical/health surveillance programs by scheduling regular blood testing, monitoring results, and educating employees.
NASA Astrophysics Data System (ADS)
Zong, Zhanguo; Ohuchi, Norihito; Tsuchiya, Kiyosumi; Arimoto, Yasushi
2016-09-01
Forty-three superconducting (SC) correction coils with maximum currents of about 60 A are installed in the SuperKEKB final focusing magnet system. Current leads to energize the SC correction coils should have an affordable heat load and fit the spatial constraints in the service cryostat where the current leads are installed. To address the requirements, design optimization of individual lead was performed with vapor cooled current lead made of a brass material, and a compact unit was designed to accommodate eight current leads together in order to be installed with one port in the service cryostat. The 2nd generation high temperature SC (HTS) tape was adopted and soldered at the cold end of the brass current lead to form a hybrid HTS lead structure. A prototype of the compact lead unit with HTS tape was constructed and tested with liquid helium (LHe) environment. This paper presents a cryogenic measurement system to simulate the real operation conditions in the service cryostat, and analysis of the experimental results. The measured results showed excellent agreement with the theoretical analysis and numerical simulation. In total, 11 sets of the compact HTS lead units were constructed for the 43 SC correction coils at KEK. One set from the mass production was tested in cryogenic conditions, and exhibited the same performance as the prototype. The compact HTS lead unit can feed currents to four SC correction coils simultaneously with the simple requirement of controlling and monitoring helium vapor flow, and has a heat load of about 0.762 L/h in terms of LHe consumption.
21 CFR 862.3550 - Lead test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Lead test system. (a) Identification. A lead test system is a device intended to measure lead, a heavy metal, in blood and urine. Measurements obtained by this device are used in the diagnosis and treatment...
21 CFR 862.3550 - Lead test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Lead test system. (a) Identification. A lead test system is a device intended to measure lead, a heavy metal, in blood and urine. Measurements obtained by this device are used in the diagnosis and treatment...
21 CFR 862.3550 - Lead test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Lead test system. (a) Identification. A lead test system is a device intended to measure lead, a heavy metal, in blood and urine. Measurements obtained by this device are used in the diagnosis and treatment...
21 CFR 862.3550 - Lead test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Lead test system. (a) Identification. A lead test system is a device intended to measure lead, a heavy metal, in blood and urine. Measurements obtained by this device are used in the diagnosis and treatment...
21 CFR 862.3550 - Lead test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Lead test system. (a) Identification. A lead test system is a device intended to measure lead, a heavy metal, in blood and urine. Measurements obtained by this device are used in the diagnosis and treatment...
NASA Astrophysics Data System (ADS)
Rocca, E.; Bourguignon, G.; Steinmetz, J.
Since several years, lead calcium-based alloys have supplanted lead antimony alloys as structural materials for positive grids of lead-acid batteries in many applications, especially for VRLA batteries. Nevertheless, the positive grid corrosion probably remains one of the causes of rapid and premature failure of lead-acid batteries. The objective of the present study is to present a comprehensive study of the PbCaSn alloy corrosion in function of their composition, metallographic state and voltage conditions (discharge, overcharge, floating and cycling conditions). For that, four alloys PbCaSn x wt.% (x = 0, 0.6, 1.2, 2) were synthesized in two extreme metallurgical conditions and tested by four electrochemical lab-tests. Weight loss measurements and analyses by SEM, EPMA and XRD allowed to monitor the oxidation tests and to characterize the corrosion layers after the oxidation tests. The results show that the tin level in PbCaSn alloys should be adapted on the calcium concentration and the rate of overageing process, to maintain the beneficial effect of tin in service during the battery lifetime. According to our results, a Sn/Ca ratio of 2.5 gives good corrosion resistance in all potential conditions. Nevertheless, when tin level is too high, the corrosion layers can peel off from the metal, which involves a lack of cohesion between the collector and the paste, in cycling conditions. The anodic potential undergone by the metal is a second main factor determining the corrosion, especially the floating conditions and the frequency of deep discharge and overcharge. Thus the adjustment of the charge controller parameters of a battery system is a necessity to increase the lifetime of the grids and maintain a good rechargeability.
Pediatric lead poisoning from folk prescription for treating epilepsy.
Ying, Xiao-Lan; Xu, Jian; Markowitz, Morri; Yan, Chong-Huai
2016-10-01
A case of lead poisoning resulting from the ingestion of a folk remedy for treating epilepsy is reported. The initial blood lead concentration of this 6-y-old boy was 63.6μg/dl upon admission. He presented with abdominal pain, constipation, and irritability. The patient's liver function tests were significantly increased. Through chelation therapy, the blood lead concentration dropped markedly and clinical symptoms greatly improved. His blood and urine samples were collected for the kinetic analysis of lead elimination. Folk prescriptions for epilepsy should be considered as potential sources of lead intoxication. Lead poisoning should be taken into consideration for unknown causes of abdominal pain. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Taheri, A.; Askari, M.; Taghan Sasanpour, M.
2017-08-01
This paper studies the effect of lead wrapping on the response of the plastic scintillators as gamma detectors. Experimental tests and Geant4 simulations showed that lead wrapping cannot increase the gamma absorption efficiency of the detector but, as a reflector, it can improve the optical properties of the detector. The reflectivity of the lead foil as an optical reflector was determined equal to 66% using an experimental-simulation combined method. Based on the obtained results, the optical collection efficiency of the detector was also increased about 4% after employing the lead reflector.
Testing of sealed lead-acid batteries
NASA Astrophysics Data System (ADS)
Bush, D. M.; Sealey, J. D.; Miller, D. W.
1984-02-01
Sealed lead acid batteries under development were tested. The goal was to develop a totally maintenance free sealed lead acid battery capable of deep discharge operation in a photovoltaic power system. Sealed lead acid batteries and a group of conventional, flooded lead acid batteries were exposed to a matrix test plan, with some approaching 1000 cycles. This performance was achieved with the standard National Electrical Manufacturers' Association cycle test, and the partial state of charge cycle test. Modes of failure are investigated.
Test and Analysis Correlation of Form Impact onto Space Shuttle Wing Leading Edge RCC Panel 8
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Lyle, Karen H.; Gabrys, Jonathan; Melis, Matthew; Carney, Kelly
2004-01-01
Soon after the Columbia Accident Investigation Board (CAIB) began their study of the space shuttle Columbia accident, "physics-based" analyses using LS-DYNA were applied to characterize the expected damage to the Reinforced Carbon-Carbon (RCC) leading edge from high-speed foam impacts. Forensic evidence quickly led CAIB investigators to concentrate on the left wing leading edge RCC panels. This paper will concentrate on the test of the left-wing RCC panel 8 conducted at Southwest Research Institute (SwRI) and the correlation with an LS-DYNA analysis. The successful correlation of the LS-DYNA model has resulted in the use of LS-DYNA as a predictive tool for characterizing the threshold of damage for impacts of various debris such as foam, ice, and ablators onto the RCC leading edge for shuttle return-to-flight.
NASA Technical Reports Server (NTRS)
Wittliff, C. E.
1982-01-01
The aerodynamic heating of a tip-fin controller mounted on a Space Shuttle Orbiter model was studied experimentally in the Calspan Advanced Technology Center 96 inch Hypersonic Shock Tunnel. A 0.0175 scale model was tested at Mach numbers from 10 to 17.5 at angles of attack typical of a shuttle entry. The study was conducted in two phases. In phase 1 testing a thermographic phosphor technique was used to qualitatively determine the areas of high heat-transfer rates. Based on the results of this phase, the model was instrumented with 40 thin-film resistance thermometers to obtain quantitative measurements of the aerodynamic heating. The results of the phase 2 testing indicate that the highest heating rates, which occur on the leading edge of the tip-fin controller, are very sensitive to angle of attack for alpha or = 30 deg. The shock wave from the leading edge of the orbiter wing impinges on the leading edge of the tip-fin controller resulting in peak values of h/h(Ref) in the range from 1.5 to 2.0. Away from the leading edge, the heat-transfer rates never exceed h/h(Ref) = 0.25 when the control surface, is not deflected. With the control surface deflected 20 deg, the heat-transfer rates had a maximum value of h/h(Ref) = 0.3. The heating rates are quite nonuniform over the outboard surface and are sensitive to angle of attack.
Usability of a New Writing Assistive Device for Persons with Cervical Spinal Cord Injury.
Lim, MyungJoon; Park, Jiyoung; Lee, Kuem Ju; Kweon, Hyosun; Kim, Byungchul; Cho, Kyujin; Choi, Hyun
2015-01-01
The hand function for persons with cervical spinal cord injury (PCSCI) is most frequently cause difficulties in leading normal lives. The purpose of this study was to test the usability of a new writing assistive device (NWAD) for PCSCI. To access its usability, the authors design usability testing method and test the NWAD to five individuals with cervical spinal cord injury. From the usability testing, we have found number of issues that lead us to key design concept about developing the NWAD. The NWAD will be redesigned based on the result of the present study. We expect that the NWAD will help PCSCI use their affected hand better and improve the level of independence and quality of life.
Characterizing the mammography technologist workforce in North Carolina
Henderson, Louise M.; Marsh, Mary W.; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F.; Bowling, J. Michael; Viglione, Cheryl A.; Yankaskas, Bonnie C.
2016-01-01
Background Mammography technologists’ level of training, years of experience, and feedback on technique may play an important role in the breast cancer screening process. However, very little information on the mammography technologist workforce exists. Methods In 2013, we conducted a mailed survey to 912 mammography technologists working in 224 Mammography Quality Standards Act accredited facilities in North Carolina. Using standard survey methodology we developed and implemented a questionnaire focused on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for non-response. We describe and compare lead (administrative responsibilities) and non-lead (supervised by another technologist) mammography technologist characteristics, testing for differences using t-tests and chi-square tests. Results A total of 433 mammography technologists responded (survey response rate=47.5%; 95% confidence interval:44.2%-50.7%), including 128 lead and 305 non-lead technologists. Most mammography technologists were non-Hispanic, white, females and the average age was 48 years. Approximately 93% of lead and non-lead technologists had mammography specific training but <4% had sonography certification and 3% had MRI certification. Lead technologists reported more years performing screening mammography (p-value=0.02) and film mammography (p-value=0.03), more administrative hours (p-value<0.0001), and more workplace autonomy (p-value=0.002) than non-lead technologists. Non-lead technologists were more likely to report performing diagnostic mammograms (p-value=0.0004) or other breast imaging (p-value=0.001), discuss image quality with a peer (p-value=0.013), and have frequent face-to-face interaction with radiologists (p-value=0.03). Conclusion Our findings offer insights into mammography technologists’ training and work experiences, highlighting variability in technologist characteristics between lead and non-lead technologists. PMID:26614888
NASA Astrophysics Data System (ADS)
Utami, N. R.; Widiyaningrum, P.; Iswari, R. S.
2018-03-01
Fish is a water biota commonly used as the bioindicator of water pollution level. One of the animals which are recommended by EPA as the test species is red Nile Tilapia fish (Oreochromis niloticus var). The purpose of this research is to get the value of LC50-96 hours in the toxicity test toward the fishes which are exposed to lead acetate with some details identification of the gills damage by gill histologic structure examination together with the determination of the lead concentration which caused the destruction. Sixty fish were used in the preliminary test to detect the threshold concentration (LC0-48 h); whereas 120 fish were used in the toxicity test to get the mortality level of fish up to 50% in 96 h. Finally, for treatment test, there were 80 fish which were exposed to lead acetate in the concentration of 0 ppm, 259.51 ppm, 291.94 ppm and 324.38 ppm. All the treatment tests were given for four weeks. The data were collected at the end of the 4th week, and then, the description of the fish gill histology structure was done. The histology observation of the fishes gill detected some damages in the form of edema (0% -25%), lamellar fusion (1% -75%), hyperplasia (0% -50%), epithelial lifting (0% -50%), and necrosis (0% -50%). The results indicate that administration of lead acetate accelerates moderate damage to the red Nile tilapia fish gill structure. The greatest level of damage is lamellar fusion, while the other decline damages are edema, hyperplasia, epithelial lifting, and necrosis. Furthermore, it can be concluded that LC50-96 hours value in the lead acetate toxicity test of red Nile tilapia fish is 324,38 ppm with some histologic structure damage in the gill the fishes.
NASA Astrophysics Data System (ADS)
Deng, Qihuang; Fan, Yuchi; Wang, Lianjun; Xiong, Zhi; Wang, Hongzhi; Li, Yaogang; Zhang, Qinghong; Kawasaki, Akira; Jiang, Wan
2012-01-01
Pb(Zr,Ti)O3 (PZT) ceramics were prepared by the conventional mixed oxide method, and the strength of the resultant PZT ceramics was evaluated using modified small punch (MSP) tests. Load-displacement curve test results showed that the crack-initiation and fracture strengths of PZT ceramics decreased after polarization. The effect of the polarization accelerated the fatigue properties of PZT ceramics. Scanning electron microscopy (SEM) results showed that microcracks were formed before the maximum load in the MSP test, and the first load drop corresponded to crack initiation.
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Test leads. 192.471... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false External corrosion control: Test leads. 192.471... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the...
Latimer, Jennifer C; Van Halen, David; Speer, James; Krull, Stephanie; Weaver, Patricia; Pettit, Joseph; Foxx, Heather
2016-10-01
Industrial emissions, deteriorating or improperly removed lead paint, and the use of lead additives in fuel have left a substantial burden of heavy metals, such as lead, in urban soils. Much of this lead remains near the surface where it has the potential to impact human health. Exposure to lead, especially in children, can have lasting impacts on neurological development and academic achievement. Urban gardening, in particular, is an activity that could result in increased exposure to soil lead for many unsuspecting gardeners. During the summer of 2012, more than 1,061 surface soil samples were collected from an approximately 1.25 acre urban community garden in Terre Haute, Indiana. Samples were collected to evaluate the spatial distribution of lead across the community garden on the plot level. The results highlight the variability that can be seen within small areas of a former residential property, for example lead concentrations that are low (<200 parts per million [ppm]) within the same 10 x 10 foot garden plot as concentrations that are considered high (>600 ppm). Based on the results of this work, several areas of concern were identified and the community garden was reconfigured to reduce potential lead exposure to gardeners and the local community.
Solar Energy Evolution and Diffusion Studies: 2014-2016 | Solar Research |
motivations for adoption A non-adopter considerer survey that targeted lost leads by installers to identify two experimental market pilots to test methods to increase lead generation and conversion using concerned individuals may need to emphasize non-environmental benefits. The results also support leveraging
Bartsch, Sarah M; Umscheid, Craig A; Nachamkin, Irving; Hamilton, Keith; Lee, Bruce Y
2015-01-01
Accurate diagnosis of Clostridium difficile infection (CDI) is essential to effectively managing patients and preventing transmission. Despite the availability of several diagnostic tests, the optimal strategy is debatable and their economic values are unknown. We modified our previously existing C. difficile simulation model to determine the economic value of different CDI diagnostic approaches from the hospital perspective. We evaluated four diagnostic methods for a patient suspected of having CDI: 1) toxin A/B enzyme immunoassay, 2) glutamate dehydrogenase (GDH) antigen/toxin AB combined in one test, 3) nucleic acid amplification test (NAAT), and 4) GDH antigen/toxin AB combination test with NAAT confirmation of indeterminate results. Sensitivity analysis varied the proportion of those tested with clinically significant diarrhoea, the probability of CDI, NAAT cost and CDI treatment delay resulting from a false-negative test, length of stay and diagnostic sensitivity and specificity. The GDH/toxin AB plus NAAT approach leads to the timeliest treatment with the fewest unnecessary treatments given, resulted in the best bed management and generated the lowest cost. The NAAT-alone approach also leads to timely treatment. The GDH/toxin AB diagnostic (without NAAT confirmation) approach resulted in a large number of delayed treatments, but results in the fewest secondary colonisations. Results were robust to the sensitivity analysis. Choosing the right diagnostic approach is a matter of cost and test accuracy. GDH/toxin AB plus NAAT diagnosis led to the timeliest treatment and was the least costly. Copyright © 2014 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Primary Prevention of Lead Exposure—Blood Lead Results at Age Two Years
Campbell, Carla; Gracely, Edward; Tran, Mary; Starkey, Naomi; Kersten, Hans; Palermo, Peter; Rothman, Nancy; Line, Laura; Hansen-Turton, Tine
2012-01-01
Objectives: The Philadelphia Lead Safe Homes (LSH) Study was designed to evaluate whether educational and environmental interventions in the first year of life for families of newborns increased knowledge of lead exposure prevention and were associated with less elevation of blood lead levels (BLLs) for these children, when compared to children receiving standard care. Methods: The current study performed descriptive statistics on the second-year BLL data for both groups and compared these using chi-square tests for proportions and unpaired t-tests for means. Results: A BLL result was found for 159 (50.6%) of the 314 LSH cohort children and 331 (52.7%) of the 628 control children (p = 0.1). Mean and standard deviation for age at draw was 23.8 (3.4) months versus 23.6 (3.1) months (P = 0.6). Geometric mean BLLs were 3.7 versus 3.5 µg/dL (P = 0.4). The percentages of the cohort group with a BLL of ≥20, ≥10 and ≥5 μg/dL, respectively, were 0.6%, 5% and 30%; for the controls 1.2%, 6.6%, and 25%. These percentages were not significantly different between groups. Conclusion: A comparison of geometric mean BLLs and percentages above several BLL cut points drawn at age two years in a group of urban newborns benefitting from study interventions versus a group of similar urban children did not yield statistically significant differences. Both groups had relatively lower lead levels when compared to historical cohort groups, which may reflect a continuing downward trend in BLLs in U.S. children. The interventions did result in benefits to the families such as an increase in parental knowledge about lead exposure prevention and in-home wet cleaning activity, and a decrease in lead dust levels in study homes. PMID:22690192
Laboratory diagnosis of Phytophthora ramorum from field samples
Cheryl Blomquist; Thomas L. Kubisiak
2003-01-01
A plant disease should never be diagnosed on the basis of a single test. Using as much information as possible leads to the most informed diagnosis. The species of host plant, its symptoms, the location of the plant, the status of the county or state (known infested versus not infested with the pathogen), the culture results, and the results of DNA tests...
NASA Technical Reports Server (NTRS)
Werlink, Rudolph J.; Pena, Francisco
2015-01-01
This Paper will describe the results of pressurization to failure of 100 gallon composite tanks using liquid nitrogen. Advanced methods of health monitoring will be compared as will the experimental data to a finite element model. The testing is wholly under NASA including unique PZT (Lead Zirconate Titanate) based active vibration technology. Other technologies include fiber optics strain based systems including NASA AFRC technology, Acoustic Emission, Acellent smart sensor, this work is expected to lead to a practical in-Sutu system for composite tanks.
A design procedure for fan inflow control structures
NASA Technical Reports Server (NTRS)
Gedge, M. R.
1980-01-01
Significant differences exist in the noise generated by engine in flight and engines operating on the test stand. It was observed that these differences can be reduced by use of an inflow control structure (ICS) in the static test configuration. The results of the second phase of a three phase program are described and the results of a test program conducted to assess and modify various theoretical models, leading to the development of an ICS design system is summarized.
Wing-section optimization for supersonic viscous flow
NASA Technical Reports Server (NTRS)
Item, Cem C.; Baysal, Oktay (Editor)
1995-01-01
To improve the shape of a supersonic wing, an automated method that also includes higher fidelity to the flow physics is desirable. With this impetus, an aerodynamic optimization methodology incorporating thin-layer Navier-Stokes equations and sensitivity analysis had been previously developed. Prior to embarking upon the wind design task, the present investigation concentrated on testing the feasibility of the methodology, and the identification of adequate problem formulations, by defining two-dimensional, cost-effective test cases. Starting with two distinctly different initial airfoils, two independent shape optimizations resulted in shapes with similar features: slightly cambered, parabolic profiles with sharp leading- and trailing-edges. Secondly, the normal section to the subsonic portion of the leading edge, which had a high normal angle-of-attack, was considered. The optimization resulted in a shape with twist and camber which eliminated the adverse pressure gradient, hence, exploiting the leading-edge thrust. The wing section shapes obtained in all the test cases had the features predicted by previous studies. Therefore, it was concluded that the flowfield analyses and sensitivity coefficients were computed and fed to the present gradient-based optimizer correctly. Also, as a result of the present two-dimensional study, suggestions were made for the problem formulations which should contribute to an effective wing shape optimization.
Investigation of blood lead concentrations in dogs living in Flint, Michigan.
Langlois, Daniel K; Kaneene, John B; Yuzbasiyan-Gurkan, Vilma; Daniels, Barbara L; Mejia-Abreu, Hilda; Frank, Nancy A; Buchweitz, John P
2017-10-15
OBJECTIVE To measure blood lead concentrations (BLCs) in dogs living in Flint, Mich, following a declared water crisis and to assess potential associations of BLCs with demographic data, water sources, and clinical signs in these dogs. DESIGN Cross-sectional study. ANIMALS 284 dogs residing in Flint, Mich (test population), and 47 dogs residing in East Lansing, Mich (control population), and immediately adjacent areas. PROCEDURES Blood samples were collected at free screening clinics in Flint (test population) and at the Michigan State University College of Veterinary Medicine Veterinary Medical Center (control population). Owners of test population dogs completed questionnaires providing demographic and clinical information. Hematologic evaluations were performed; BLCs were measured by inductively coupled plasma-mass spectrometry. RESULTS 4 of 284 test population dogs had BLCs > 50 ppb; an additional 20 had BLCs > 20 ppb. Overall, BLCs of test population dogs were higher than those of control dogs. Within the test population, young dogs (≤ 2 years of age) had higher BLCs than old dogs (≥ 6 years of age). Only 7.2% of test population dogs were drinking unfiltered tap water at the time of screening; however, dogs that had been receiving filtered or bottled water for ≤ 3 months before screening had higher BLCs than did those that received such water for > 3 months. CONCLUSIONS AND CLINICAL RELEVANCE Taken together, findings suggested that the impact of the Flint water crisis extended to companion animals. Results highlighted the importance of maintaining awareness of lead exposure and considering both human and animal well-being in cases of environmental toxicant exposures.
Ultrasonic fatigue of a high strength steel
NASA Astrophysics Data System (ADS)
Koster, M.; Wagner, G.; Eifler, D.
2010-07-01
At the Institute of Materials Science and Engineering at the University of Kaiserslautern an ultrasonic testing system for the fatigue assessment of metallic materials in the very high cycle fatigue (VHCF) regime was developed. The ultrasonic testing system allows to control the test and to measure detailed fatigue data. The achieved results can be used to describe the cyclic deformation behaviour of wheel steels at ultrasonic frequencies. In load increase tests (LIT), the critical stress amplitude can be determined, which leads to a defined change of process parameters like generator power, dissipated energy and specimen temperature. With SEM investigations it was proved that the change of the process parameters correlates with irreversible changes in the microstructure. It can be shown that the stress amplitude, leading to first irreversible changes in the microstructure, strongly depends on the depth position within the original wheel rim. New and basic results on the fatigue mechanisms of high strength steels in the VHCF-regime can be achieved.
Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care
Menon, Shailaja; Murphy, Daniel R.; Singh, Hardeep; Meyer, Ashley N. D.
2016-01-01
Summary Background Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. Objective To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. Methods We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Results Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Conclusion Workarounds to manage EHR-based test results are common, and their use results from unmet provider information management needs. Future EHRs and the respective work systems around them need to evolve to meet these needs. PMID:27437060
NASA Technical Reports Server (NTRS)
Weiberg, James A.; Holzhauser, Curt A.
1961-01-01
Tests were made of a large-scale tilt-wing deflected-slipstream VTOL airplane with blowing-type BLC trailing-edge flaps. The model was tested with flap deflections of 0 deg. without BLC, 50 deg. with and without BLC, and 80 deg. with BLC for wing-tilt angles of 0, 30, and 50 deg. Included are results of tests of the model equipped with a leading-edge flap and the results of tests of the model in the presence of a ground plane.
Characterizing the Material Properties of Polymer-Based Microelectrode Arrays for Retinal Prosthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Christina Soyeun
2003-06-01
The Retinal Prosthesis project is a three year project conducted in part at the Lawrence Livermore National Laboratory and funded by the Department of Energy to create an epiretinal microelectrode array for stimulating retinal cells. The implant must be flexible to conform to the retina, robust to sustain handling during fabrication and implantation, and biocompatible to withstand physiological conditions within the eye. Using poly(dimethyl siloxane) (PDMS), LLNL aims to use microfabrication techniques to increase the number of electrodes and integrate electronics. After the initial designs were fabricated and tested in acute implantation, it became obvious that there was a needmore » to characterize and understand the mechanical and electrical properties of these new structures. This knowledge would be imperative in gaining credibility for polymer microfabrication and optimizing the designs. Thin composite microfabricated devices are challenging to characterize because they are difficult to handle, and exhibit non-linear, viscoelastic, and anisotropic properties. The objective of this research is to device experiments and protocols, develop an analytical model to represent the composite behavior, design and fabricate test structures, and conduct experimental testing to determine the mechanical and electrical properties of PDMS-metal composites. Previous uniaxial stretch tests show an average of 7% strain before failure on resistive heaters of similar dimensions deposited on PDMS. Lack of background information and questionable human accuracy demands a more sophisticated and thorough testing method. An Instron tensile testing machine was set up to interface with a digital multiplexor and computer interface to simultaneously record and graph position, load, and resistance across devices. With a compliant load cell for testing polymers and electrical interconnect grips designed and fabricated to interface the sample to the electronics, real-time resistance measurements were taken. Wafers of test structures were fabricated with variables such as lead width, pad to lead interface shape, PDMS thickness, metal (Ti and Au) thickness, and lead shape. Results showed that the serpentine shaped leads were 70% more effective, and that thicker adhesion layers of Ti were too brittle for testing. The other variables did not produce significant results.« less
Characterization of the Roman curse tablet
NASA Astrophysics Data System (ADS)
Liu, Wen; Zhang, Boyang; Fu, Lin
2017-08-01
The Roman curse tablet, produced in ancient Rome period, is a metal plate that inscribed with curses. In this research, several techniques were used to find out the physical structure and chemical composition of the Roman curse tablet, and testified the hypothesis that whether the tablet is made of pure lead or lead alloy. A sample of Roman Curse Tablet from the Johns Hopkins Archaeological Museum was analyzed using several different characterization techniques to determine the physical structure and chemical composition. The characterization techniques used were including optical microscopy, scanning electron microscopy (SEM), atomic force microscopy (AFM), and differential scanning calorimetry (DSC). Because of the small sample size, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and X-ray fluorescence (XRF) cannot test the sample. Results from optical microscopy and SEM, enlarged images of the sample surface were studied. The result revealed that the sample surface has a rough, non-uniform, and grainy surface. AFM provides three-dimensional topography of the sample surface, studying the sample surface in atomic level. DSC studies the thermal property, which is most likely a lead-alloy, not a pure lead. However, none of these tests indicated anything about the chemical composition. Future work will be required due to the lack of measures finding out its chemical composition. Therefore, from these characterization techniques above, the Roman curse tablet sample is consisted of lead alloy, not pure lead.
Factors Accounting for a Missed Diagnosis of Cystic Fibrosis After Newborn Screening
Rock, Michael J.; Levy, Hara; Zaleski, Christina; Farrell, Philip M.
2015-01-01
Summary Newborn screening is a public health policy program involving the centralized testing laboratory, infant and their family, primary care provider, and subspecialist for confirmatory testing and follow-up of abnormal results. Cystic fibrosis (CF) newborn screening has now been enacted in all 50 states and the District of Columbia and throughout many countries in the world. Although CF neonatal screening will identify the vast majority of infants with CF, there are many factors in the newborn screening system that can lead to a missed diagnosis of CF. To inform clinicians, this article summarizes the CF newborn screening system and highlights 14 factors that can account for a missed diagnosis of CF. Care providers should maintain a high suspicion for CF if there are compatible symptoms, regardless of the results of the newborn screening test. These factors in newborn screening programs leading to a missed diagnosis of CF present opportunities for quality improvement in specimen collection, laboratory analysis of immunoreactive tryspinogen (IRT) and CF mutation testing, communication, and sweat testing. PMID:22081556
Calibration of sonic valves for the laminar flow control, leading-edge flight test
NASA Technical Reports Server (NTRS)
Petley, D. H.; Alexander, W., Jr.; Wright, A. S., Jr.; Vallas, M.
1985-01-01
Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure were measured for total temperatures from -30 F to 75 F and total pressures from 120 to 540 psf. Correlating equations are obtained for mass-flow rate as a function of total pressure, total temperature, and valve opening length. The most important aspect of flow measurement and control is found to be the measurement of valve opening length.
Results from service tests on AI-91 gasoline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turovskii, F.V.; Bakaleinik, A.M.; Belyaev, A.A.
1988-01-01
Research was conducted to establish whether the operational reliability of engines will be affected by the use of a gasoline with an octane number two points lower than that of commercial AI-93 leaded gasoline with knock resistance in acceleration that is better than that of the AI-93 by approximately the same amount. Extended road tests were run in VAZ-2106 and Moskvich-2140 automobiles using gasoline with a research octane number of 91, containing an antiknock additive based on tetramethyl lead, and AI-93. The experimental AI-91 and the commercial AI-93 gasolines were prepared from the same base blend. Average specific fuel consumptionsmore » were identical for automobiles using AI-93 and AI-91 with the tetramethyl lead additive. For automobiles using AI-91 with the additive and with ethyl bromide as a lead scavenger the fuel consumption was 2% lower.« less
Effect of Discharge Rate on Positive Active Material of Lead Carbon Battery for Energy Storage
NASA Astrophysics Data System (ADS)
Chen, Kailun; Liu, Hao; Hu, Chen; Gao, Fei; Yang, Kai; Wang, Hao
2017-10-01
Lead carbon battery has been widespread concern with its excellent performance of charge and discharge under High Rate Part State of Charge (HRPSoC) as well as its cycle performance. In this paper, the cycling performance of lead carbon battery for energy storage was tested by different discharge rate. The effects of different discharge rate on the composition and morphology of positive active materials in the cycle was studied by XRD and SEM. The effect of different discharge rate on the ohmic impedance of lead carbon battery was studied by testing Electrochemical Impedance Spectroscopy with different capacity retention rates. The results show that with the increase of the discharge rate, the content of PbO2 in the positive active material increases, the active substance utilization and the particle size of PbO2 crystal declines, and the ohmic impedance of the battery decreases.
NASA Technical Reports Server (NTRS)
Chapman, Gary T.
1961-01-01
The tests were conducted at Mach numbers from 2.8 to 5.3, with model surface temperatures small compared to boundary-layer recovery temperature. The effects of Mach number, temperature ratio, unit Reynolds number, leading-edge diameter, and angle of attack were investigated in an exploratory fashion. The effect of heat-transfer condition (i.e., wall temperature to total temperature ratio) and Mach number can not be separated explicitly in free-flight tests. However, the data of the present report, as well as those of NACA TN 3473, were found to be more consistent when plotted versus temperature ratio. Decreasing temperature ratio increased the transition Reynolds number. The effect of unit Reynolds number was small as was the effect of leading-edge diameter within the range tested. At small values of angle of attack, transition moved forward on the windward surface and rearward on the leeward surface. This trend was reversed at high angles of attack (6 deg to 18 deg). Possible reasons for this are the reduction of crossflow on the windward side and the influence of the lifting vortices on the leeward surface. When the transition results on the 740 delta wing were compared to data at similar test conditions for an unswept leading edge, the results bore out the results of earlier research at nearly zero heat transfer; namely, sweep causes a large reduction in the transition Reynolds number.
[Analysis on heavy metal pollution in major seafoods from Zhoushan Fishery, China].
Wang, Jian-Yue; Wang, Yu-Chao; Lou, Jiang-Hong
2012-10-01
Through reviewing data on surveys, tested materials especially on lead in Zhoushan fisheries, with ground lead, cadmium and methyl-mercury were analyzed and evaluated. According to the distribution of Zhoushan fisheries, we randomly selected a certain number of Zhoushan seafood as research objects from four counties or districts. Different kinds of seafood would include sea fish, seawater crustaceans, seawater soft-bodied animals and sea algae. The inedible parts of all the seafood were removed, and then the samples of the edible parts were grinding into homogenate. We measured the contents of lead and cadmium, using graphite furnace atomic absorption spectrometry method. The content of methylmercury was measured, using the gas chromatography (acid extraction method of mercaptoacetic cotton). Data from 2007 to 2009 was analyzed under SPSS software. (1) The average standardized rates were: lead as 3.90% (11/282), cadmium as 11.35% (32/282) and methylmercury as 2.84% (8/282). (2) Results from the comprehensive evaluation on the contents of metals showed the following rankings: seaweed (0.4513 mg/kg), marine molluscs (0.1155 mg/kg), marine crustaceans (0.0486 mg/kg), sea-fish (0.0419 mg/kg). (3) Results from the single-factor variance analysis showed that the accumulation of lead, cadmium and methylmercury in different types of seafood were: lead F = 35.683 (P < 0.001); cadmium F = 25.301 (P < 0.001); methylmercury F = 25.990 (P < 0.001). (4) Data on the safety analysis related to the different types of seafood on lead, cadmium, methylmercury food, the Chi-square tests showed as: lead χ(2) = 10.167, P < 0.05; cadmium χ(2) = 62.940, P < 0.001; methylmercury χ(2) = 20.960, P < 0.001. (5) Seafood in different years on lead, cadmium, methylmercury accumulation comparison, the Spearman correlation test results showed: lead P = 0.000, cadmium P = 0.974, methylmercury P = 0.024. (6) The contents of seafood lead, cadmium and methylmercury in different years that with statistically significant differences were as follows: lead χ(2) = 6.440, P < 0.05; cadmium χ(2) = 34.455, P < 0.001; methylmercury χ(2) = 5.226, P > 0.05. The situation of heavy metal pollution in different kinds of Zhoushan fisheries was different. Algae appeared the worst while sea fish, sea water crustaceans pollution were light, with lead and methylmercury mainly influencing sea algae and cadmium mainly in the sea algae, followed by seawater software class. The rates over standards of different kinds of seafood were different from each other, while the rates over standards of lead, cadmium and methylmercury in sea algae were the highest. Evaluated by pollution index, lead, methylmercury pollution was still low, but cadmium in the sea with mild pollution in algae seafood. In the recent three years, heavy metal lead pollution in seafood were worsened, while the cadmium, methylmercury pollution levels remained basically stable.
NASA Astrophysics Data System (ADS)
Xue, Q.; Tang, J., Sr.; Chen, H.
2017-12-01
High concentrations of ammonium sulfate, often used in the in-situ mining process, can result in a decrease of pH in the environment and dissolution of rare earth metals. Ammonium sulfate can also cause desorption of toxic heavy metals, leading to environmental and human health implications. In this study, the desorption behavior and fraction changes of lead in the ion-absorbed rare earth ore were studied using batch desorption experiments and column leaching tests. Results from batch desorption experiments showed that the desorption process of lead included fast and slow stages, and followed an Elovich model well. The desorption rate and the proportion of lead content in the solution to the total lead in the soil were observed to increase with a decrease in the initial pH of the ammonium sulfate solution. The lead in soil included an acid extractable fraction, reducible fraction, oxidizable fraction, and a residual fraction, with the predominant fractions being the reducible and acid extractable fractions. 96% of the extractable fraction in soil were desorbed into solution at pH=3.0, and the content of the reducible fraction was observed to initially increase (when pH>4.0) and then decrease (when pH<4.0) with a decrease in pH. Column leaching tests indicated that the content of lead in the different fractions of soil followed the trend of reducible fraction > oxidizable fraction > acid extractable fraction > residual fraction after the simulating leaching mining process. The change in pH was also found to have a larger influence on the acid extractable and reducible fractions than the other two fractions. The proportion of the extractable fraction being leached was ca. 86%, and the reducible fraction was enriched along the migration direction of the leaching liquid. These results suggest that certain lead fractions may desorb again and contaminate the environment via acid rain, which provides significant information for environmental assessment and remediation after mining process.
A study of high-lift airfoils at high Reynolds numbers in the Langley low-turbulence pressure tunnel
NASA Technical Reports Server (NTRS)
Morgan, Harry L., Jr.; Ferris, James C.; Mcghee, Robert J.
1987-01-01
An experimental study was conducted in the Langley Low Turbulence Pressure Tunnel to determine the effects of Reynolds number and Mach number on the two-dimensional aerodynamic performance of two supercritical type airfoils, one equipped with a conventional flap system and the other with an advanced high lift flap system. The conventional flap system consisted of a leading edge slat and a double slotted, trailing edge flap with a small chord vane and a large chord aft flap. The advanced flap system consisted of a leading edge slat and a double slotted, trailing edge flap with a large chord vane and a small chord aft flap. Both models were tested with all elements nested to form the cruise airfoil and with the leading edge slat and with a single or double slotted, trailing edge flap deflected to form the high lift airfoils. The experimental tests were conducted through a Reynolds number range from 2.8 to 20.9 x 1,000,000 and a Mach number range from 0.10 to 0.35. Lift and pitching moment data were obtained. Summaries of the test results obtained are presented and comparisons are made between the observed aerodynamic performance trends for both models. The results showing the effect of leading edge frost and glaze ice formation is given.
A Model Program for Translational Medicine in Epilepsy Genetics
Smith, Lacey A.; Ullmann, Jeremy F. P.; Olson, Heather E.; El Achkar, Christelle M.; Truglio, Gessica; Kelly, McKenna; Rosen-Sheidley, Beth; Poduri, Annapurna
2017-01-01
Recent technological advances in gene sequencing have led to a rapid increase in gene discovery in epilepsy. However, the ability to assess pathogenicity of variants, provide functional analysis, and develop targeted therapies has not kept pace with rapid advances in sequencing technology. Thus, although clinical genetic testing may lead to a specific molecular diagnosis for some patients, test results often lead to more questions than answers. As the field begins to focus on therapeutic applications of genetic diagnoses using precision medicine, developing processes that offer more than equivocal test results is essential. The success of precision medicine in epilepsy relies on establishing a correct genetic diagnosis, analyzing functional consequences of genetic variants, screening potential therapeutics in the preclinical laboratory setting, and initiating targeted therapy trials for patients. We describe the structure of a comprehensive, pediatric Epilepsy Genetics Program that can serve as a model for translational medicine in epilepsy. PMID:28056630
[Evaluation of the reliability of freight elevator operators].
Gosk, A; Borodulin-Nadzieja, L; Janocha, A; Salomon, E
1991-01-01
The study involved 58 workers employed at winding machines. Their reliability was estimated from the results of psychomotoric test precision, condition of the vegetative nervous system, and from the results of psychological tests. The tests were carried out at the laboratory and at the workplaces, with all distractive factors and functional connection of the work process present. We have found that the reliability of the workers may be affected by a variety of factors. Among the winding machine operators, work monotony can lead to "monotony syndrome". Among the signalists , the appreciation of great responsibility can lead to unpredictable and non-adequate reactions. From both groups, persons displaying a lower-than-average precision were isolated. All those persons demonstrated a reckless attitude and the opinion of their superiors about them was poor. Those persons constitute potential risk for the reliable operation of the discussed team.
NASA Technical Reports Server (NTRS)
Carta, F. O.
1982-01-01
Tests were conducted on a linear cascade of airfoils oscillating in pitch to measure the unsteady pressure response on selected blades along the leading edge plane of the cascade, over the chord of the center blade, and on the sidewall in the plane of the leading edge. The pressure data were reduced to Fourier coefficient form for direct comparison, and were also processed to yield integrated loads and, particularly, the aerodynamic damping coefficient. Results from the unsteady Verdon/Caspar theory for cascaded blades with nonzero thickness and camber were compared with the experimental measurements. The three primary results are: (1) from the leading edge plane blade data, the cascade was judged to be periodic in unsteady flow over the range of parameters tested; (2) the interblade phase angle was found to be the single most important parameter affecting the stability of the oscillating cascade blades; and (3) the real blade theory and the experiment were in excellent agreement for the several cases chosen for comparison.
Lead and mercury in fall migrant golden eagles from western North America.
Langner, Heiko W; Domenech, Robert; Slabe, Vincent A; Sullivan, Sean P
2015-07-01
Lead exposure from ingestion of bullet fragments is a serious environmental hazard to eagles. We determined blood lead levels (BLL) in 178 golden eagles (Aquila chrysaetos) captured during fall migration along a major North American flyway. These eagles spent the breeding season distributed over a large range and are the best currently available representation of free flying golden eagles on the continent. We found 58 % of these eagles containing increased BLL > 0.1 mg/L; 10 % were clinically lead poisoned with BLL > 0.6 mg/L; and 4 % were lethally exposed with BLL > 1.2 mg/L. No statistical difference in BLL existed between golden and bald eagles (Haliaeetus leucocephalus). Golden eagles captured on carrion had higher BLL than those captured using live bait suggesting differences in feeding habits among individuals. Median BLL increased with age class. We propose a conceptual model for the long-term increase in BLL after ingestion of lead particles. The mean blood mercury level in golden eagles was 0.023 mg/L. We evaluate a field test for BLL that is based on anodic stripping voltammetry. This cost-effective and immediate method correlated well with results from inductively coupled plasma-mass spectrometry, although results needed to be corrected for each calibration of the test kit.
Lead Poisoning at an Indoor Firing Range.
Kang, Kyung Wook; Park, Won Ju
2017-10-01
In March 2014, a 39-year-old Korean male presented with a 6-month history of various nonspecific symptoms including dizziness, fatigue, asthenia, irritability, elevated blood pressure, palpitation, eyestrain, and tinnitus. His occupational history revealed that he had been working as an indoor firing range manager for 13 months; therefore, he was subjected to a blood lead level (BLL) test. The test results showed a BLL of 64 μg/dL; hence, he was diagnosed with lead poisoning and immediately withdrawn from work. As evident from the workplace environmental monitoring, the level of lead exposure in the air exceeded its limit (0.015-0.387 mg/m³). He received chelation treatment with calcium-disodium ethylenediaminetetraacetic acid (1 g/day) for 5 days without any adverse effects. In the follow-up results after 2 months, the BLL had decreased to 9.7 μg/dL and the symptoms resolved. This report represents the first occupational case of lead poisoning in firing ranges in Korea, and this necessitates institutional management to prevent the recurrence of poisoning through this route. Workplace environmental monitoring should be implemented for indoor firing ranges, and the workers should undergo regularly scheduled special health examinations. In clinical practice, it is essential to question the patient about his occupational history. © 2017 The Korean Academy of Medical Sciences.
High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging
NASA Technical Reports Server (NTRS)
Rahman, Atiar
2006-01-01
Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.
Cambiano, Valentina; Ford, Deborah; Mabugu, Travor; Napierala Mavedzenge, Sue; Miners, Alec; Mugurungi, Owen; Nakagawa, Fumiyo; Revill, Paul; Phillips, Andrew
2015-01-01
Background Studies have demonstrated that self-testing for human immunodeficiency virus (HIV) is highly acceptable among individuals and could allow cost savings, compared with provider-delivered HIV testing and counseling (PHTC), although the longer-term population-level effects are uncertain. We evaluated the cost-effectiveness of introducing self-testing in 2015 over a 20-year time frame in a country such as Zimbabwe. Methods The HIV synthesis model was used. Two scenarios were considered. In the reference scenario, self-testing is not available, and the rate of first-time and repeat PHTC is assumed to increase from 2015 onward, in line with past trends. In the intervention scenario, self-testing is introduced at a unit cost of $3. Results We predict that the introduction of self-testing would lead to modest savings in healthcare costs of $75 million, while averting around 7000 disability-adjusted life-years over 20 years. Findings were robust to most variations in assumptions; however, higher cost of self-testing, lower linkage to care for people whose diagnosis is a consequence of a positive self-test result, and lower threshold for antiretroviral therapy eligibility criteria could lead to situations in which self-testing is not cost-effective. Conclusions This analysis suggests that introducing self-testing offers some health benefits and may well save costs. PMID:25767214
Geotechnical Centrifuge Experiments to Evaluate Piping in Foundation Soils
2014-05-01
verifiable results. These tests were successful in design , construction, and execution of a realistic simulation of internal erosion leading to failure...possible “scale effects,” “modeling of models” testing protocol should be included in the test program. Also, the model design should minimize the scale...recommendations for improving the centrifuge tests include the following: • Design improved system for reservoir control to provide definitive and
Press, Barry
2011-01-01
In vitro permeability assays are a valuable tool for scientists during lead compound optimization. As a majority of discovery projects are focused on the development of orally bioavailable drugs, correlation of in vitro permeability data to in vivo absorption results is critical for understanding the structural-physicochemical relationship (SPR) of drugs exhibiting low levels of absorption. For more than a decade, the Caco-2 screening assay has remained a popular, in vitro system to test compounds for both intestinal permeability and efflux liability. Despite advances in artificial membrane technology and in silico modeling systems, drug compounds still benefit from testing in cell-based epithelial monolayer assays for lead optimization. This chapter provides technical information for performing and optimizing the Caco-2 assay. In addition, techniques are discussed for dealing with some of the most pressing issues surrounding in vitro permeability assays (i.e., low aqueous solubility of test compounds and low postassay recovery). Insights are offered to help researchers avoid common pitfalls in the interpretation of in vitro permeability data, which can often lead to the perception of misleading results for correlation to in vivo data.
Lead-contaminated imported tamarind candy and children's blood lead levels.
Lynch, R A; Boatright, D T; Moss, S K
2000-01-01
In 1999, an investigation implicated tamarind candy as the potential source of lead exposure for a child with a significantly elevated blood lead level (BLL). The Oklahoma City-County Health Department tested two types of tamarind suckers and their packaging for lead content. More than 50% of the tested suckers exceeded the US Food and Drug Administration (FDA) Level of Concern for lead in this type of product. The authors calculated that a child consuming one-quarter to one-half of either of the two types of suckers in a day would exceed the maximum FDA Provis onal Tolerable Intake for lead. High lead concentrations in the two types of wrappers suggested leaching as a potential source of contamination. The authors used the Environmental Protection Agency's Integrated Exposure Uptake Biokinetic (IEUBK) model to predict the effects of consumption of contaminated tamarind suckers on populat on BLLs. The IEUBK model predicted that consumption of either type of sucker at a rate of one per day would result in dramatic increases in mean BLLs for children ages 6-84 months in Oklahoma and in the percentage of children wth elevated BLLs (> or =10 micrograms per deciliter [microg/dL]). The authors conclude that consumption of these products represents a potential public health threat. In addition, a history of lead contamination in imported tamarind products suggests that import control measures may not be completely effective in preventing additional lead exposure.
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2012 CFR
2012-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2014 CFR
2014-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2011 CFR
2011-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2013 CFR
2013-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
Petito Boyce, Catherine; Sax, Sonja N; Cohen, Joel M
2017-08-01
Inhalation plays an important role in exposures to lead in airborne particulate matter in occupational settings, and particle size determines where and how much of airborne lead is deposited in the respiratory tract and how much is subsequently absorbed into the body. Although some occupational airborne lead particle size data have been published, limited information is available reflecting current workplace conditions in the U.S. To address this data gap, the Battery Council International (BCI) conducted workplace monitoring studies at nine lead acid battery manufacturing facilities (BMFs) and five secondary smelter facilities (SSFs) across the U.S. This article presents the results of the BCI studies focusing on the particle size distributions calculated from Personal Marple Impactor sampling data and particle deposition estimates in each of the three major respiratory tract regions derived using the Multiple-Path Particle Dosimetry model. The BCI data showed the presence of predominantly larger-sized particles in the work environments evaluated, with average mass median aerodynamic diameters (MMADs) ranging from 21-32 µm for the three BMF job categories and from 15-25 µm for the five SSF job categories tested. The BCI data also indicated that the percentage of lead mass measured at the sampled facilities in the submicron range (i.e., <1 µm, a particle size range associated with enhanced absorption of associated lead) was generally small. The estimated average percentages of lead mass in the submicron range for the tested job categories ranged from 0.8-3.3% at the BMFs and from 0.44-6.1% at the SSFs. Variability was observed in the particle size distributions across job categories and facilities, and sensitivity analyses were conducted to explore this variability. The BCI results were compared with results reported in the scientific literature. Screening-level analyses were also conducted to explore the overall degree of lead absorption potentially associated with the observed particle size distributions and to identify key issues associated with applying such data to set occupational exposure limits for lead.
Optical simulation of a Popescu-Rohrlich Box
Chu, Wen-Jing; Zong, Xiao-Lan; Yang, Ming; Pan, Guo-Zhu; Cao, Zhuo-Liang
2016-01-01
It is well known that the fair-sampling loophole in Bell test opened by the selection of the state to be measured can lead to post-quantum correlations. In this paper, we make the selection of the results after measurement, which opens the fair- sampling loophole too, and thus can lead to post-quantum correlations. This kind of result-selection loophole can be realized by pre- and post-selection processes within the “two-state vector formalism”, and a physical simulation of Popescu-Rohrlich (PR) box is designed in linear optical system. The probability distribution of the PR has a maximal CHSH value 4, i.e. it can maximally violate CHSH inequality. Because the “two-state vector formalism” violates the information causality, it opens the locality loophole too, which means that this kind of results selection within “two-state vector formalism” leads to both fair- sampling loophole and locality loophole, so we call it a comprehensive loophole in Bell test. The comprehensive loophole opened by the results selection within “two-state vector formalism” may be another possible explanation of why post-quantum correlations are incompatible with quantum mechanics and seem not to exist in nature. PMID:27329203
Optical simulation of a Popescu-Rohrlich Box.
Chu, Wen-Jing; Zong, Xiao-Lan; Yang, Ming; Pan, Guo-Zhu; Cao, Zhuo-Liang
2016-06-22
It is well known that the fair-sampling loophole in Bell test opened by the selection of the state to be measured can lead to post-quantum correlations. In this paper, we make the selection of the results after measurement, which opens the fair- sampling loophole too, and thus can lead to post-quantum correlations. This kind of result-selection loophole can be realized by pre- and post-selection processes within the "two-state vector formalism", and a physical simulation of Popescu-Rohrlich (PR) box is designed in linear optical system. The probability distribution of the PR has a maximal CHSH value 4, i.e. it can maximally violate CHSH inequality. Because the "two-state vector formalism" violates the information causality, it opens the locality loophole too, which means that this kind of results selection within "two-state vector formalism" leads to both fair- sampling loophole and locality loophole, so we call it a comprehensive loophole in Bell test. The comprehensive loophole opened by the results selection within "two-state vector formalism" may be another possible explanation of why post-quantum correlations are incompatible with quantum mechanics and seem not to exist in nature.
Rodrigues, Ema G.; Virji, M. Abbas; McClean, Michael D.; Weinberg, Janice; Woskie, Susan; Pepper, Lewis D.
2009-01-01
Bridge painters are exposed to lead during several job tasks performed during the workday, such as sanding, scraping, and blasting. After the Occupational Safety and Health Administration standard was passed in 1993 to control lead exposures among construction workers including bridge painters, this study was conducted among 84 bridge painters in the New England area to determine the significant predictors of blood lead levels. Lead was measured in personal air and hand wipe samples that were collected during the 2-week study period and in blood samples that were collected at the beginning and at the end of the study period. The personal air and hand wipe data as well as personal behaviors (i.e., smoking, washing, wearing a respirator) and work site conditions were analyzed as potential determinants of blood lead levels using linear mixed effects models. Our results show that the mean air lead levels over the 2-week period were the most predictive exposure measure of blood lead levels. Other individual-level significant predictors of blood lead levels included months worked on bridge painting crews, education, and personal hygiene index. Of the site-level variables investigated, having a containment facility on site was a significant predictor of blood lead levels. Our results also indicate that hand wipe lead levels were significantly associated with higher blood lead levels at the end of the study period compared with the beginning of the study period. Similarly, smoking on site and respirator fit testing were significantly associated with higher blood lead levels at the end of the study period. This study shows that several individual-level and site-level factors are associated with blood lead levels among bridge painters, including lead exposure through inhalation and possible hand-to-mouth contact, personal behaviors such as smoking on site, respirator fit testing, and work site conditions such as the use of better containment facilities. Accordingly, reduction in blood lead levels among bridge painters can be achieved by improving these workplace practices. PMID:19953411
McCrindle, Jennifer; Green, Donna; Sullivan, Marianne
2017-01-01
The associations between environmental lead exposure and high school educational outcomes in four communities located in New South Wales, Australia, were examined in this ecological study. A mixed model analysis was performed to account for each school’s results being more similar than results for other schools. The effect of environmental lead exposure on mean results for five educational outcomes was examined. ‘Leaded’ schools with more than five per cent of students living in the highest lead risk areas were tested against non-leaded ‘comparison’ schools that were matched by a pre-defined socio-educational advantage rating. A small disadvantage was found for leaded schools for four out of five outcomes, which was statistically significant for three outcomes: Higher School Certificate English (p < 0.01), School Certificate Mathematics (p < 0.05), and Australian Tertiary Admissions Rank eligibility rate (p < 0.01). This study adds to the large body of evidence in Australia and elsewhere supporting the importance of primary prevention to protect health at multiple stages of development. PMID:29144415
Prosocial preferences do not explain human cooperation in public-goods games
Burton-Chellew, Maxwell N.; West, Stuart A.
2013-01-01
It has become an accepted paradigm that humans have “prosocial preferences” that lead to higher levels of cooperation than those that would maximize their personal financial gain. However, the existence of prosocial preferences has been inferred post hoc from the results of economic games, rather than with direct experimental tests. Here, we test how behavior in a public-goods game is influenced by knowledge of the consequences of actions for other players. We found that (i) individuals cooperate at similar levels, even when they are not informed that their behavior benefits others; (ii) an increased awareness of how cooperation benefits others leads to a reduction, rather than an increase, in the level of cooperation; and (iii) cooperation can be either lower or higher than expected, depending on experimental design. Overall, these results contradict the suggested role of the prosocial preferences hypothesis and show how the complexity of human behavior can lead to misleading conclusions from controlled laboratory experiments. PMID:23248298
Prosocial preferences do not explain human cooperation in public-goods games.
Burton-Chellew, Maxwell N; West, Stuart A
2013-01-02
It has become an accepted paradigm that humans have "prosocial preferences" that lead to higher levels of cooperation than those that would maximize their personal financial gain. However, the existence of prosocial preferences has been inferred post hoc from the results of economic games, rather than with direct experimental tests. Here, we test how behavior in a public-goods game is influenced by knowledge of the consequences of actions for other players. We found that (i) individuals cooperate at similar levels, even when they are not informed that their behavior benefits others; (ii) an increased awareness of how cooperation benefits others leads to a reduction, rather than an increase, in the level of cooperation; and (iii) cooperation can be either lower or higher than expected, depending on experimental design. Overall, these results contradict the suggested role of the prosocial preferences hypothesis and show how the complexity of human behavior can lead to misleading conclusions from controlled laboratory experiments.
Effects of chronic lead intoxication on rat serotoninergic system and anxiety behavior.
Sansar, Wafa; Bouyatas, My Mustapha; Ahboucha, Samir; Gamrani, Halima
2012-01-01
Chronic lead exposure has been shown to produce behavioral disturbances in human and animal models. These disturbances are associated with alterations in monoaminergic neurotransmission in the central nervous system (CNS), some of which have been attributed to serotonin (5-HT). This study was undertaken to investigate the chronic effects of lead exposure on the serotoninergic system in the dorsal raphe nucleus (DRN) and the consequences of its toxicity on rat behavior. Adult male Wistar rats were chronically exposed for 3 months to 0.5% lead acetate in drinking water. The serotoninergic system was evaluated using immunohistochemistry and the anxiety behavior was assessed by the light/dark box test. The results show that chronic lead exposure induces a significant increase of blood and brain lead levels in treated rats compared with controls. The density of the immunoreactive serotoninergic cell bodies was significantly higher in treated rats in all parts of the DRN. Assessment of animal behavior using the light/dark box test showed that lead-treated rats spent significantly more time in the light chamber compared with controls (P=0.001). These findings suggest that lead exposure may possibly induce increased anxiety as a consequence of changes in neuronal 5-HT content in the DRN. Copyright © 2011 Elsevier GmbH. All rights reserved.
Occupational Potential in a Population with Duchenne Muscular Dystrophy.
ERIC Educational Resources Information Center
Schkade, Janette K.; And Others
1987-01-01
Twenty-five males with Duchenne muscular dystrophy were tested to assess their potential for occupational activity. Tests measured possible sensory deficits, strength, endurance, and fatigue in response to sustained fine motor activity. Results indicate that, within limitations, persons with this diagnosis can engage in activity leading to skill…
Threaded average temperature thermocouple
NASA Technical Reports Server (NTRS)
Ward, Stanley W. (Inventor)
1990-01-01
A threaded average temperature thermocouple 11 is provided to measure the average temperature of a test situs of a test material 30. A ceramic insulator rod 15 with two parallel holes 17 and 18 through the length thereof is securely fitted in a cylinder 16, which is bored along the longitudinal axis of symmetry of threaded bolt 12. Threaded bolt 12 is composed of material having thermal properties similar to those of test material 30. Leads of a thermocouple wire 20 leading from a remotely situated temperature sensing device 35 are each fed through one of the holes 17 or 18, secured at head end 13 of ceramic insulator rod 15, and exit at tip end 14. Each lead of thermocouple wire 20 is bent into and secured in an opposite radial groove 25 in tip end 14 of threaded bolt 12. Resulting threaded average temperature thermocouple 11 is ready to be inserted into cylindrical receptacle 32. The tip end 14 of the threaded average temperature thermocouple 11 is in intimate contact with receptacle 32. A jam nut 36 secures the threaded average temperature thermocouple 11 to test material 30.
Eco-Balance analysis of the disused lead-acid-batteries recycling technology
NASA Astrophysics Data System (ADS)
Kamińska, Ewa; Kamiński, Tomasz
2017-10-01
The article presents the results of the eco-balance analysis of the disused lead-acid batteries recycling process. Test-dedicated technology offers the possibility to recover other elements, for example, polypropylene of the battery case or to obtain crystalline sodium sulphate. The life cycle assessment was made using ReCiPe and IMPACT2002 + methods. The results are shown as environmental points [Pt]. The results are shown in the environmental categories, specific for each of the methods grouped in the impact categories. 1 Mg of the processed srap was a dopted as the functional unit. The results of the analyses indicate that recycling processes may provide the environmental impact of recycling technology less harmful. Repeated use of lead causes that its original sources are not explored. Similarly, the use of granule production-dedicated polypropylene extracted from battery casings that are used in the plastics industry, has environmental benefits. Due to the widespread use of lead-acid batteries, the attention should be paid to their proper utilization, especially in terms of heavy metals, especially lead. According to the calculations, the highest level of environmental benefits from the use of lead from secondary sources in the production of new products, was observed in the refining process.
Automated lung sound analysis for detecting pulmonary abnormalities.
Datta, Shreyasi; Dutta Choudhury, Anirban; Deshpande, Parijat; Bhattacharya, Sakyajit; Pal, Arpan
2017-07-01
Identification of pulmonary diseases comprises of accurate auscultation as well as elaborate and expensive pulmonary function tests. Prior arts have shown that pulmonary diseases lead to abnormal lung sounds such as wheezes and crackles. This paper introduces novel spectral and spectrogram features, which are further refined by Maximal Information Coefficient, leading to the classification of healthy and abnormal lung sounds. A balanced lung sound dataset, consisting of publicly available data and data collected with a low-cost in-house digital stethoscope are used. The performance of the classifier is validated over several randomly selected non-overlapping training and validation samples and tested on separate subjects for two separate test cases: (a) overlapping and (b) non-overlapping data sources in training and testing. The results reveal that the proposed method sustains an accuracy of 80% even for non-overlapping data sources in training and testing.
Gelled-electrolyte batteries for electric vehicles
NASA Astrophysics Data System (ADS)
Tuphorn, Hans
Increasing problems of air pollution have pushed activities of electric vehicle projects worldwide and in spite of projects for developing new battery systems for high energy densities, today lead/acid batteries are almost the single system, ready for technical usage in this application. Valve-regulated lead/acid batteries with gelled electrolyte have the advantage that no maintenance is required and because the gel system does not cause problems with electrolyte stratification, no additional appliances for central filling or acid addition are required, which makes the system simple. Those batteries with high density active masses indicate high endurance results and field tests with 40 VW-CityStromers, equipped with 96 V/160 A h gel batteries with thermal management show good results during four years. In addition, gelled lead/acid batteries possess superior high rate performance compared with conventional lead/acid batteries, which guarantees good acceleration results of the car and which makes the system recommendable for application in electric vehicles.
Fletcher, A M; Gelberg, K H; Marshall, E G
1999-06-01
The purpose of this study was to examine the circumstances under which women receive blood lead tests in New York State and to characterize the sources of lead exposure among women of childbearing age with moderate blood lead levels. Telephone interviews were conducted with 135 women between the ages of 18 and 45, with blood lead levels from 10 through 25 micrograms/dl, were used to collect information on the reason for their blood lead test and possible sources of lead exposure. It was found that the two most common reasons to be tested for blood lead were workplace screening (47%) and pregnancy (27%). Occupational exposure was the primary source of lead exposure in this population (46%). Another common source of lead exposure was home renovation (24%). A significant proportion (31%) of women with blood lead levels from 10 through 25 micrograms/dl had no known current source of lead exposure. Based on New York's sample, there are a significant number of women of reproductive age with potentially fetotoxic blood lead levels.
Masuda, Elna M; Lee, Raymond W; Okazaki, Ian J; Benyamini, Pouya; Kistner, Robert L
2015-04-01
Management of venous thromboembolism (VTE) includes evaluation for hypercoagulable state, especially if the VTE occurs in young patients, is recurrent, or is associated with a positive family history. These laboratory tests are costly, and surprisingly, there is little evidence showing that testing leads to improved clinical outcomes. Evidence based on observational prospective studies suggests that optimal duration of anticoagulation should be based on clinical risks resulting in VTE, such as transient, permanent, and idiopathic or unprovoked risks, and less on abnormal thrombophilia values. Thrombophilia screening is important in a subgroup of clinical scenarios, such as when there is clinical suspicion of antiphospholipid antibody syndrome, heparin resistance, or warfarin necrosis; with thrombosis occurring in unusual sites (such as mesenteric or cerebral deep venous thrombosis); and for pregnant women or those seeking pregnancy or considering estrogen-based agents. Thrombophilia screening is not likely to be helpful in most cases of first-time unprovoked VTE in the setting of transient risks, active malignant disease, deep venous thrombosis of upper extremity veins or from central lines, two or more VTEs, or arterial thrombosis with pre-existing atherosclerotic risk factors. The desire by both patient and physician for a scientific explanation of the clotting event may alone lead to testing, and if so, it should be with the understanding that an abnormal test result will likely not change management, and normal results do not accurately exclude a thrombophilic defect because there are likely factors yet to be discovered. Such false assumptions may lead to shorter durations of treatment than are optimal. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Analysis of airfoil leading edge separation bubbles
NASA Technical Reports Server (NTRS)
Carter, J. E.; Vatsa, V. N.
1982-01-01
A local inviscid-viscous interaction technique was developed for the analysis of low speed airfoil leading edge transitional separation bubbles. In this analysis an inverse boundary layer finite difference analysis is solved iteratively with a Cauchy integral representation of the inviscid flow which is assumed to be a linear perturbation to a known global viscous airfoil analysis. Favorable comparisons with data indicate the overall validity of the present localized interaction approach. In addition numerical tests were performed to test the sensitivity of the computed results to the mesh size, limits on the Cauchy integral, and the location of the transition region.
Assessment of Child Lead Exposure in a Philadelphia Community, 2014.
Dignam, Timothy; Pomales, Ana; Werner, Lora; Newbern, E Claire; Hodge, James; Nielsen, Jay; Grober, Aaron; Scruton, Karen; Young, Rand; Kelly, Jack; Brown, Mary Jean
2018-01-10
Several urban neighborhoods in Philadelphia, Pennsylvania, have a history of soil, household lead paint, and potential lead-emitting industry contamination. To (1) describe blood lead levels (BLLs) in target neighborhoods, (2) identify risk factors and sources of lead exposure, (3) describe household environmental lead levels, and (4) compare results with existing data. A simple, random, cross-sectional sampling strategy was used to enroll children 8 years or younger living in selected Philadelphia neighborhoods with a history of lead-emitting industry during July 2014. Geometric mean of child BLLs and prevalence of BLLs of 5 μg/dL or more were calculated. Linear and logistic regression analyses were used to ascertain risk factors for elevated BLLs. Among 104 children tested for blood lead, 13 (12.4%; 95% confidence interval [CI], 7.5-20.2) had BLLs of 5 μg/dL or more. The geometric mean BLL was 2.0 μg/dL (95% CI, 1.7-2.3 μg/dL). Higher geometric mean BLLs were significantly associated with front door entryway dust lead content, residence built prior to 1900, and a child currently or ever receiving Medicaid. Seventy-one percent of households exceeded the screening level for soil, 25% had an elevated front door floor dust lead level, 28% had an elevated child play area floor dust lead level, and 14% had an elevated interior window dust lead level. Children in households with 2 to 3 elevated environmental lead samples were more likely to have BLLs of 5 μg/dL or more. A spatial relationship between household proximity to historic lead-emitting facilities and child BLL was not identified. Entryway floor dust lead levels were strongly associated with blood lead levels in participants. Results underscore the importance to make housing lead safe by addressing all lead hazards in and around the home. Reduction of child lead exposure is crucial, and continued blood lead surveillance, testing, and inspection of homes of children with BLLs of 5 μg/dL or more to identify and control lead sources are recommended. Pediatric health care providers can be especially vigilant screening Medicaid-eligible/enrolled children and children living in very old housing.
NASA Astrophysics Data System (ADS)
Poertner, T.
1993-11-01
Glow discharge flow visualization experiments are demonstrated which have been performed to enable a first assessment of the HERMES 1.0 leading edge thruster configuration concerning interference between the thruster plumes of the reaction control system (RCS) and the surrounding flow field. The results of the flow visualization tests are presented in exemplary selected photographs. Additional Pitot pressure measurements support assumptions concerning interference induced pressure changes that may result from the observed significant flow field disturbances.
Potyrailo, Radislav A; Chisholm, Bret J; Morris, William G; Cawse, James N; Flanagan, William P; Hassib, Lamyaa; Molaison, Chris A; Ezbiansky, Karin; Medford, George; Reitz, Hariklia
2003-01-01
Coupling of combinatorial chemistry methods with high-throughput (HT) performance testing and measurements of resulting properties has provided a powerful set of tools for the 10-fold accelerated discovery of new high-performance coating materials for automotive applications. Our approach replaces labor-intensive steps with automated systems for evaluation of adhesion of 8 x 6 arrays of coating elements that are discretely deposited on a single 9 x 12 cm plastic substrate. Performance of coatings is evaluated with respect to their resistance to adhesion loss, because this parameter is one of the primary considerations in end-use automotive applications. Our HT adhesion evaluation provides previously unavailable capabilities of high speed and reproducibility of testing by using a robotic automation, an expanded range of types of tested coatings by using the coating tagging strategy, and an improved quantitation by using high signal-to-noise automatic imaging. Upon testing, the coatings undergo changes that are impossible to quantitatively predict using existing knowledge. Using our HT methodology, we have developed several coatings leads. These HT screening results for the best coating compositions have been validated on the traditional scales of coating formulation and adhesion loss testing. These validation results have confirmed the superb performance of combinatorially developed coatings over conventional coatings on the traditional scale.
Ecological impacts of lead mining on Ozark streams: toxicity of sediment and pore water.
Besser, John M; Brumbaugh, William G; Allert, Ann L; Poulton, Barry C; Schmitt, Christopher J; Ingersoll, Christopher G
2009-02-01
We studied the toxicity of sediments downstream of lead-zinc mining areas in southeast Missouri, using chronic sediment toxicity tests with the amphipod, Hyalella azteca, and pore-water toxicity tests with the daphnid, Ceriodaphnia dubia. Tests conducted in 2002 documented reduced survival of amphipods in stream sediments collected near mining areas and reduced survival and reproduction of daphnids in most pore waters tested. Additional amphipod tests conducted in 2004 documented significant toxic effects of sediments from three streams downstream of mining areas: Strother Creek, West Fork Black River, and Bee Fork. Greatest toxicity occurred in sediments from a 6-km reach of upper Strother Creek, but significant toxic effects occurred in sediments collected at least 14 km downstream of mining in all three watersheds. Toxic effects were significantly correlated with metal concentrations (nickel, zinc, cadmium, and lead) in sediments and pore waters and were generally consistent with predictions of metal toxicity risks based on sediment quality guidelines, although ammonia and manganese may also have contributed to toxicity at a few sites. Responses of amphipods in sediment toxicity tests were significantly correlated with characteristics of benthic invertebrate communities in study streams. These results indicate that toxicity of metals associated with sediments contributes to adverse ecological effects in streams draining the Viburnum Trend mining district.
Ecological impacts of lead mining on Ozark streams: Toxicity of sediment and pore water
Besser, J.M.; Brumbaugh, W.G.; Allert, A.L.; Poulton, B.C.; Schmitt, C.J.; Ingersoll, C.G.
2009-01-01
We studied the toxicity of sediments downstream of lead-zinc mining areas in southeast Missouri, using chronic sediment toxicity tests with the amphipod, Hyalella azteca, and pore-water toxicity tests with the daphnid, Ceriodaphnia dubia. Tests conducted in 2002 documented reduced survival of amphipods in stream sediments collected near mining areas and reduced survival and reproduction of daphnids in most pore waters tested. Additional amphipod tests conducted in 2004 documented significant toxic effects of sediments from three streams downstream of mining areas: Strother Creek, West Fork Black River, and Bee Fork. Greatest toxicity occurred in sediments from a 6-km reach of upper Strother Creek, but significant toxic effects occurred in sediments collected at least 14 km downstream of mining in all three watersheds. Toxic effects were significantly correlated with metal concentrations (nickel, zinc, cadmium, and lead) in sediments and pore waters and were generally consistent with predictions of metal toxicity risks based on sediment quality guidelines, although ammonia and manganese may also have contributed to toxicity at a few sites. Responses of amphipods in sediment toxicity tests were significantly correlated with characteristics of benthic invertebrate communities in study streams. These results indicate that toxicity of metals associated with sediments contributes to adverse ecological effects in streams draining the Viburnum Trend mining district.
What limits the achievable areal densities of large aperture space telescopes?
NASA Astrophysics Data System (ADS)
Peterson, Lee D.; Hinkle, Jason D.
2005-08-01
This paper examines requirements trades involving areal density for large space telescope mirrors. A segmented mirror architecture is used to define a quantitative example that leads to relevant insight about the trades. In this architecture, the mirror consists of segments of non-structural optical elements held in place by a structural truss that rests behind the segments. An analysis is presented of the driving design requirements for typical on-orbit loads and ground-test loads. It is shown that the driving on-orbit load would be the resonance of the lowest mode of the mirror by a reaction wheel static unbalance. The driving ground-test load would be dynamics due to ground-induced random vibration. Two general conclusions are derived from these results. First, the areal density that can be allocated to the segments depends on the depth allocated to the structure. More depth in the structure allows the allocation of more mass to the segments. This, however, leads to large structural depth that might be a significant development challenge. Second, the requirement for ground-test-ability results in an order of magnitude or more depth in the structure than is required by the on-orbit loads. This leads to the proposition that avoiding ground test as a driving requirement should be a fundamental technology on par with the provision of deployable depth. Both are important structural challenges for these future systems.
Mironer, Y Eugene; Brown, Christopher; Satterthwaite, John R; Cohen, Mary; Tonder, Lisa M; Grumman, Steve
2004-01-01
Spinal cord stimulation (SCS) is a popular method of treatment of chronic pain. Unfortunately, migration of the lead continues to be a serious complication of this therapy. In an attempt to reduce lateral migration of the SCS lead, we performed a retrospective assessment of a new technique of percutaneous lead placement. This new method of "midline anchoring" of the lead using the plica mediana dorsalis was tested against conventional technique in a retrospective study involving 122 trials and 91 implants of SCS over a period of five years. The use of "midline anchoring" resulted in a decrease in lead migration from 23% to 6% after trial insertion and from 24% to 7% after implantation. We conclude that "midline anchoring" of the SCS lead is an effective method of preventing lead migration.
RQL Sector Rig Testing of SiC/SiC Combustor Liners
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Martin, Lisa C.; Brewer, David N.
2002-01-01
Combustor liners, manufactured from silicon carbide fiber-reinforced silicon carbide (SiC/SiC) were tested for 260 hr using a simulated gas turbine engine cycle. This report documents the results of the last 56 hr of testing. Damage occurred in one of the six different components that make up the combustor liner set, the rich zone liner. Cracks in the rich zone liner initiated at the leading edge due to stresses resulting from the component attachment configuration. Thin film thermocouples and fiber optic pyrometers were used to measure the rich zone liner's temperature and these results are reported.
Design feasibility of an advanced technology supersonic cruise aircraft
NASA Technical Reports Server (NTRS)
Rowe, W. T.
1976-01-01
Research and development programs provide confidence that technology is in-hand to design an economically attractive, environmentally sound supersonic cruise aircraft for commercial operations. The principal results of studies and tests are described including those which define the selection of significant design features. These typically include the results of: (1) wind-tunnel tests, both subsonic and supersonic, (2) propulsion performance and acoustic tests on noise suppressors, including forward-flight effects, (3) studies of engine/airframe integration, which lead to the selection of engine cycles/sizes to meet future market, economic, and social requirements; and (4) structural testing.
Stability and control flight test results of the space transportation system's orbiter
NASA Technical Reports Server (NTRS)
Culp, M. A.; Cooke, D. R.
1982-01-01
Flight testing of the Space Shuttle Orbiter is in progress and current results of the post-flight aerodynamic analyses are discussed. The purpose of these analyses is to reduce the pre-flight aerodynamic uncertainties, thereby leading to operational certification of the Orbiter flight envelope relative to the integrated airframe and flight control system. Primary data reduction is accomplished with a well documented maximum likelihood system identification techniques.
Reversible surface binding of cadmium and lead by lactic acid and bifidobacteria.
Teemu, Halttunen; Seppo, Salminen; Jussi, Meriluoto; Raija, Tahvonen; Kalle, Lertola
2008-07-15
Extensive cadmium and lead contamination of water has been reported to occur locally as a result of human activities. Lactic acid bacteria have been reported to remove cadmium and lead from water. The aim of this work was to clarify the mechanisms of cadmium and lead removal from water. In addition, the effect of other metals, reversibility of binding and recyclability of the biomass was assessed. Based on our earlier data, the two most promising lactic acid bacteria, Lactobacillus fermentum ME3 and Bifidobacterium longum 46, were selected for these experiments. The results showed that the presence of other cationic metals and blocking of carboxyl and phosphoryl groups reduced cadmium and lead removal. These results suggest involvement of electrostatic interactions in cadmium and lead removal, and support our earlier findings. Transmission electron micrographs showed large deposits of lead on the bacterial surface suggesting formation of metallic lead precipitates. Both cadmium and lead removal were reversible processes established by full recovery of removed metal after desorption with dilute solutions of EDTA and HNO(3). Resorption capacity of both biomasses tested was reduced after regeneration with 10 mM EDTA and 15 mM HNO(3). Taken together, the results suggest involvement of several reversible mechanisms such as ion exchange and precipitation in cadmium and lead binding by lactic acid bacteria. The results show that specific lactic acid bacteria have the potential for removal of cadmium and lead from water although reduction in resorption capacity after regeneration of the biomass may form a problem. Since the studies so far have mainly focused on removal of single metals from pure water, metal removal in conditions of natural waters should be assessed in further experiments.
Dumont, Coralie; Barroso, João; Matys, Izabela; Worth, Andrew; Casati, Silvia
2016-08-01
The knowledge of the biological mechanisms leading to the induction of skin sensitisation has favoured in recent years the development of alternative non-animal methods. During the formal validation process, results from the Local Lymph Node Assay (LLNA) are generally used as reference data to assess the predictive capacity of the non-animal tests. This study reports an analysis of the variability of the LLNA for a set of chemicals for which multiple studies are available and considers three hazard classification schemes: POS/NEG, GHS/CLP and ECETOC. As the type of vehicle used in a LLNA study is known to influence to some extent the results, two analyses were performed: considering the solvent used to test the chemicals and without considering the solvent. The results show that the number of discordant classifications increases when a chemical is tested in more than one solvent. Moreover, it can be concluded that study results leading to classification in the strongest classes (1A and EXT) seem to be more reliable than those in the weakest classes. This study highlights the importance of considering the variability of the reference data when evaluating non-animal tests. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
The Effect of the Presence of EEG Leads on Image Quality in Cerebral Perfusion SPECT and FDG PET/CT.
Zhang, Lulu; Yen, Stephanie P; Seltzer, Marc A; Thomas, George P; Willis, Kristen; Siegel, Alan
2018-06-08
Rationale: Cerebral perfusion SPECT and 18 F-FDG PET/CT are commonly performed diagnostic procedures for patients suffering from epilepsy. Individuals receiving these tests are often in-patients undergoing examinations with EEG leads. We have routinely removed these leads before these tests due to concerns that they would lead to imaging artifacts. The leads would then be replaced at the conclusion of the scan. The goal of our study was to determine if the EEG leads actually do cause artifacts that could lead to erroneous scan interpretation or make the scan uninterpretable. Methods: PET/CT with 18 F-FDG and SPECT with technetium-99m ECD were performed on a two dimensional brain phantom. The phantom was scanned with standard leads, CT/MR compatible leads and with no leads. The scans were interpreted by three experienced nuclear medicine physicians who were asked to rank the images by quality and then to determine if they could differentiate each of the scans from a scan in which it was indicated that no leads were present. Results: No differences could be detected between SPECT or PET scans performed without leads or with either set of leads. The standard EEG leads did create an artifact in the CT portion of the PET/CT while the CT/MR compatible leads did not. Conclusion: This phantom study suggest that EEG leads, standard or CT/MR compatible do not need to be removed for SPECT or for PET. Further study evaluating the effect on patients scan would be of value to support this conclusion. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Energy drinks give you wings but also an abnormal exercise test.
Choudhury, Tawfiqur R; Abdool, Muhammad A; Galasko, Gavin
2017-07-27
This is the case of a 53-year-old man with known coronary artery disease who underwent two exercise treadmill tests (ETT). The first test, which yielded an abnormal result, was undertaken shortly after he had drunk two cans of Red Bull, a popular energy drink (ED). A second ETT was undertaken 1 week later by the same team without EDs on board and the test result was normal. This case suggests that drinking EDs prior to an ETT could lead to a false positive result and should be discouraged prior to exercise testing. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Catatonic syndrome associated with lead intoxication: a case report.
Modabbernia, Mohammad Jafar; Mirsafa, Ali Reza; Modabbernia, Amirhossein; Pilehroodi, Farhad; Shirazi, Maryam
2009-08-11
Little is known about catatonia associated with lead intoxication. A retired printing house worker man presented with one week history of refusal to eat and mutism. He was treated with possible diagnosis of catatonia with administration of Lorazepam 3 mg P.O. daily. Significant improvement occurred after 48 hours. In further examinations, there was no evidence of physical and mental disorders while impairment in neuropsychiatry test, identification of Dohle body, basophilic stippling and toxic granulation in peripheral blood smear and blood lead level of 12.8 mug/dl were recorded. Possibly, lead intoxication results in changes in neurotransmitter system that leads to catatonia. Lorazepam improves patient's condition through changes in this system.
NASA Astrophysics Data System (ADS)
Czerwiński, A.; Obrębowski, S.; Kotowski, J.; Rogulski, Z.; Skowroński, J.; Bajsert, M.; Przystałowski, M.; Buczkowska-Biniecka, M.; Jankowska, E.; Baraniak, M.; Rotnicki, J.; Kopczyk, M.
Bare reticulated vitreous carbon (RVC) plated electrochemically with thin layer of lead was investigated as a negative plate carrier- and current-collector material for lead-acid batteries. Hybrid flooded single cell lead-acid batteries containing one negative plate based on a new type (RVC or Pb/RVC) of carrier/current-collector and two positive plates based on Pb-Ca grid collectors were assembled and subjected to charge/discharge tests (at 20-h and 1-h discharge rates) and Peukert's dependences determination. The promising results show that application of RVC as carrier- and current-collector in negative plate will significantly increase the specific capacity of lead-acid battery.
NASA Technical Reports Server (NTRS)
Mineck, Raymond E.; Pendergraft, Odis C., Jr.
2000-01-01
Results from three wind tunnel tests in the National Transonic Facility of a model of an advanced-technology, subsonic-transport wing-body configuration have been analyzed to assess the test-to-test repeatability of several aerodynamic parameters. The scatter, as measured by the prediction interval, in the longitudinal force and moment coefficients increases as the Mach number increases. Residual errors with and without the ESP tubes installed suggest a bias leading to lower drag with the tubes installed. Residual errors as well as average values of the longitudinal force and moment coefficients show that there are small bias errors between the different tests.
NASA Technical Reports Server (NTRS)
Loyselle, Patricia; Prokopius, Kevin
2011-01-01
Proton Exchange Membrane (PEM) fuel cell technology is the leading candidate to replace the alkaline fuel cell technology, currently used on the Shuttle, for future space missions. During a 5-yr development program, a PEM fuel cell powerplant was developed. This report details the initial performance evaluation test results of the powerplant.
Accelerated stress testing of terrestrial solar cells
NASA Technical Reports Server (NTRS)
Lathrop, J. W.; Hawkins, D. C.; Prince, J. L.; Walker, H. A.
1982-01-01
The development of an accelerated test schedule for terrestrial solar cells is described. This schedule, based on anticipated failure modes deduced from a consideration of IC failure mechanisms, involves bias-temperature testing, humidity testing (including both 85-85 and pressure cooker stress), and thermal-cycle thermal-shock testing. Results are described for 12 different unencapsulated cell types. Both gradual electrical degradation and sudden catastrophic mechanical change were observed. These effects can be used to discriminate between cell types and technologies relative to their reliability attributes. Consideration is given to identifying laboratory failure modes which might lead to severe degradation in the field through second quadrant operation. Test results indicate that the ability of most cell types to withstand accelerated stress testing depends more on the manufacturer's design, processing, and worksmanship than on the particular metallization system. Preliminary tests comparing accelerated test results on encapsulated and unencapsulated cells are described.
Impact of Low Blood Lead Concentrations on IQ and School Performance in Chinese Children
Liu, Jianghong; Li, Linda; Wang, Yingjie; Yan, Chonghuai; Liu, Xianchen
2013-01-01
Objectives Examine the relationships between blood lead concentrations and children's intelligence quotient (IQ) and school performance. Participants and Methods Participants were 1341 children (738 boys and 603 girls) from Jintan, China. Blood lead concentrations were measured when children were 3–5 years old. IQ was assessed using the Chinese version and norms of the Wechsler Preschool and Primary Scale of Intelligence – Revised when children were 6 years old. School performance was assessed by standardized city tests on 3 major subjects (Chinese, Math, and English [as a foreign language]) when children were age 8–10 years. Results Mean blood lead concentration was 6.43 µg/dL (SD = 2.64). For blood lead concentrations, 7.8% of children (n = 105) had ≥10.0 µg/dL, 13.8% (n = 185) had 8.0 to <10.0 µg/dL, and 78.4% (n = 1051) had <8.0 µg/dL. Compared to children with blood lead concentrations <8 µg/dL, those with blood lead concentrations ≥8 µg/dL scored 2–3 points lower in IQ and 5–6 points lower in school tests. There were no significant differences in IQ or school tests between children with blood lead concentrations groups 8–10 and ≥10 µg/dL. After adjustment for child and family characteristics and IQ, blood lead concentrations ≥10 µg/dL vs <8 µg/dL at ages 3–5 years was associated with reduced scores on school tests at age 8–10 years (Chinese, β = −3.54, 95%CI = −6.46, −0.63; Math, β = −4.63, 95%CI = −7.86, −1.40; English, β = −4.66, 95%CI = −8.09, −1.23). IQ partially mediated the relationship between elevated blood lead concentrations and later school performance. Conclusions Findings support that blood lead concentrations in early childhood, even <10 µg/dL, have a long-term negative impact on cognitive development. The association between blood lead concentrations 8–10 µg/dL and cognitive development needs further study in Chinese children and children from other developing countries. PMID:23734241
Influence of lead apron shielding on absorbed doses from panoramic radiography
Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D
2013-01-01
Objectives: This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. Methods: A RANDO® full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA® three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax® 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. Results: A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = −0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. Conclusions: In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding. PMID:24174012
Arc Jet Testing of the TIRS Cover Thermal Protection System for Mars Exploration Rover
NASA Technical Reports Server (NTRS)
Szalai, Christine E.; Chen, Y.-K.; Loomis, Mark; Hui, Frank; Scrivens, Larry
2002-01-01
This paper summarizes the arc jet test results of the Mars Exploration Rover (MER) Silicone Impregnated Reusable Ceramic Ablator (SIRCA) Transverse Impulse Rocket System (TIRS) Cover test series in the Panel Test Facility (PTF) at NASA Ames Research Center (ARC). NASA ARC performed aerothermal environment analyses, TPS sizing and thermal response analyses, and arc jet testing to evaluate the MER SIRCA TIRS Cover design and interface to the aeroshell structure. The primary objective of this arc jet test series was to evaluate specific design details of the SIRCA TIRS Cover interface to the MER aeroshell under simulated atmospheric entry heating conditions. Four test articles were tested in an arc jet environment with various sea] configurations. The test condition was designed to match the predicted peak flight heat load at the gap region between the SIRCA and the backshell TPS material, SLA-561S, and resulted in an over-test (with respect to heat flux and heat load) for the apex region of the SIRCA TIRS Cover. The resulting pressure differential was as much as twenty times that predicted for the flight case, depending on the location, and there was no post-test visual evidence of over-heating or damage to the seal, bracket, or backshell structure. The exposed titanium bolts were in good condition at post-test and showed only a small amount of oxidation at the leading edge locations. Repeatable thermocouple data were obtained and SIRCA thermal response analyses were compared to applicable thermocouple data. For the apex region of the SIRCA TIRS Cover, a one-dimensional thermal response prediction proved overly conservative, as there were strong multi-dimensional conduction effects evident from the thermocouple data. The one-dimensional thermal response prediction compared well with the thermocouple data for the leading edge "lip" region at the bolt location. In general, the test results yield confidence in the baseline seal design to prevent hot gas ingestion at the bracket and composite aeroshell structure interface.
Metal exposures from aluminum cookware: An unrecognized public health risk in developing countries.
Weidenhamer, Jeffrey D; Fitzpatrick, Meghann P; Biro, Alison M; Kobunski, Peter A; Hudson, Michael R; Corbin, Rebecca W; Gottesfeld, Perry
2017-02-01
Removing lead from gasoline has resulted in decreases in blood lead levels in most of the world, but blood lead levels remain elevated in low and middle-income countries compared to more developed countries. Several reasons for this difference have been investigated, but few studies have examined the potential contribution from locally-made aluminum cookware. In a previous study of cookware from a single African country, Cameroon, artisanal aluminum cookware that is made from scrap metal released significant quantities of lead. In this study, 42 intact aluminum cookware items from ten developing countries were tested for their potential to release lead and other metals during cooking. Fifteen items released ≥1 microgram of lead per serving (250mL) when tested by boiling with dilute acetic acid for 2h. One pot, from Viet Nam, released 33, 1126 and 1426 micrograms per serving in successive tests. Ten samples released >1 microgram of cadmium per serving, and fifteen items released >1 microgram of arsenic per serving. The mean exposure estimate for aluminum was 125mg per serving, more than six times the World Health Organization's Provisional Tolerable Weekly Intake of 20mg/day for a 70kg adult, and 40 of 42 items tested exceeded this level. We conducted preliminary assessments of three potential methods to reduce metal leaching from this cookware. Coating the cookware reduced aluminum exposure per serving by >98%, and similar reductions were seen for other metals as well. Potential exposure to metals by corrosion during cooking may pose a significant and largely unrecognized public health risk which deserves urgent attention. Copyright © 2016 Elsevier B.V. All rights reserved.
Causes of mortality and unintentional poisoning in predatory and scavenging birds in California
Kelly, Terra R.; Poppenga, Robert H.; Woods, Leslie A.; Hernandez, Yvette Z.; Boyce, Walter M.; Samaniego, Francisco J.; Torres, Steve G.; Johnson, Christine K.
2014-01-01
Objectives We documented causes of mortality in an opportunistic sample of golden eagles, turkey vultures and common ravens, and assessed exposure to several contaminants that have been found in carrion and common prey for these species. Methods Dead birds were submitted for testing through wildlife rehabilitation centres and a network of wildlife biologists in California from 2007 to 2009. Results The leading causes of mortality in this study were collision-related trauma (63 per cent), lead intoxication (17 per cent) and anticoagulant rodenticide poisoning (8 per cent). Elevated liver lead concentration (≥2 µg/g) and bone lead concentration (>6 µg/g) were detected in 25 and 49 per cent of birds tested, respectively. Approximately 84 per cent of birds tested had detectable rodenticide residues. The majority of rodenticide exposure occurred in peri-urban areas, suggesting that retail sale and use of commensal rodent baits, particularly in residential and semi-residential areas in California, may provide a pathway of exposure. Conclusions Monitoring anthropogenic causes of mortality in predatory and scavenging bird species provides important data needed to inform on mitigation and regulatory efforts aimed at reducing threats to these populations. PMID:26392875
Whisker Formation on SAC305 Soldered Assemblies
NASA Astrophysics Data System (ADS)
Meschter, S.; Snugovsky, P.; Bagheri, Z.; Kosiba, E.; Romansky, M.; Kennedy, J.; Snugovsky, L.; Perovic, D.
2014-11-01
This article describes the results of a whisker formation study on SAC305 assemblies, evaluating the effects of lead-frame materials and cleanliness in different environments: low-stress simulated power cycling (50-85°C thermal cycling), thermal shock (-55°C to 85°C), and high temperature/high humidity (85°C/85% RH). Cleaned and contaminated small outline transistors, large leaded quad flat packs (QFP), plastic leaded chip carrier packages, and solder balls with and without rare earth elements (REE) were soldered to custom designed test boards with Sn3Ag0.5Cu (SAC305) solder. After assembly, all the boards were cleaned, and half of them were recontaminated (1.56 µg/cm2 Cl-). Whisker length, diameter, and density were measured. Detailed metallurgical analysis on components before assembly and on solder joints before and after testing was performed. It was found that whiskers grow from solder joint fillets, where the thickness is less than 25 µm, unless REE was present. The influence of lead-frame and solder ball material, microstructure, cleanliness, and environment on whisker characteristics is discussed. This article provides detailed metallurgical observations and select whisker length data obtained during this multiyear testing program.
Hofmann, Cory L; Holyoak, Derek T; Juris, Paul M
2017-01-01
Study Design Controlled laboratory study, repeated-measures design. Background The effects of trunk and shank position on patellofemoral joint stress of the lead limb have been well studied; however, the effects on the trail limb are not well understood. Objectives To test the hypothesis that trunk and shank position may influence patellofemoral joint stress in both limbs during the forward lunge exercise. Methods Patellofemoral kinetics were quantified from 18 healthy participants performing the lunge exercise with different combinations of trunk and shank positions (vertical or forward). A 2-by-3 (limb-by-lunge variation) repeated-measures analysis of variance was performed, using paired t tests for post hoc comparisons. Results The trail limb experienced greater total patellofemoral joint stress relative to the lead limb, regardless of trunk and shank position (P<.0001). The lunge variation with a vertical shank position resulted in significantly greater peak patellofemoral joint stress in the trail limb relative to the lead limb (P<.0001). A forward trunk and shank position resulted in the highest patellofemoral stress in the lead limb (P<.0001). Conclusion Trunk and shank positions have a significant influence on patellofemoral joint loading of both limbs during the forward lunge, with the trail limb generally experiencing greater total joint stress. Restricting forward translation of the lead-limb shank may reduce patellofemoral joint stress at the expense of increased stress in the trail limb. Technique recommendations should consider the demands imposed on both knees during this exercise. J Orthop Sports Phys Ther 2017;47(1):31-40. Epub 4 Nov 2016. doi:10.2519/jospt.2017.6336.
Primary prevention of lead exposure: the Philadelphia lead safe homes study.
Campbell, Carla; Tran, Mary; Gracely, Edward; Starkey, Naomi; Kersten, Hans; Palermo, Peter; Rothman, Nancy; Line, Laura; Hansen-Turton, Tine
2011-01-01
Lead exposure in children can lead to neuropsychological impairment. This study tested whether primary prevention interventions in the newborn period prevent elevated blood lead levels (BLLs). The Philadelphia Lead Safe Homes (LSH) Study offered parental education, home evaluation, and lead remediation to the families of urban newborns. Households were randomized to a standard lead education group or maintenance education group. We conducted home visits at baseline, six months, and 12 months. To compare BLLs, we identified a matched comparison group. We enrolled and randomized 314 newborns in the intervention component; 110 completed the study. There were few significant differences between the randomized groups. In the combined intervention groups, positive results on visual inspection declined from baseline to 12 months (97.0% to 90.6%, p = 0.007). At baseline, 36.9% of homes were above the U.S. Environmental Protection Agency's lead dust standard, compared with 26.9% at 12 months (p = 0.032), mainly due to a drop in windowsill dust levels. Both groups showed a significant increase in parental scores on a lead education test. Children in the intervention and matched control groups had similar geometric mean initial BLLs (2.6 vs. 2.7, p = 0.477), but a significantly higher percentage of children in the intervention group had an initial blood lead screening compared with those in the matched group (88.9% vs. 84.4%, p = 0.032). A study of primary prevention of lead exposure showed a higher blood lead screening rate for the combined intervention groups and mean BLLs at one year of age not statistically different from the comparison group. Most homes had lead hazards. Lead education significantly increased knowledge.
... this disease. Scientific breakthroughs may lead to the design of more specific modulators of the immune system ... arthritis, or SLE may have atypical P-ANCA test results, based on the autoantibodies directed against other ...
Brown, Mary Jean; Raymond, Jaime; Homa, David; Kennedy, Chinaro; Sinks, Thomas
2011-01-01
Evaluate the effect of changes in the water disinfection process, and presence of lead service lines (LSLs), on children's blood lead levels (BLLs) in Washington, DC. Three cross-sectional analyses examined the relationship of LSL and changes in water disinfectant with BLLs in children <6 years of age. The study population was derived from the DC Childhood Lead Poisoning Prevention Program blood lead surveillance system of children who were tested and whose blood lead test results were reported to the DC Health Department. The Washington, DC Water and Sewer Authority (WASA) provided information on LSLs. The final study population consisted of 63,854 children with validated addresses. Controlling for age of housing, LSL was an independent risk factor for BLLs ≥ 10 μg/dL, and ≥ 5 μg/dL even during time periods when water levels met the US Environmental Protection Agency (EPA) action level of 15 parts per billion (ppb). When chloramine alone was used to disinfect water, the risk for BLL in the highest quartile among children in homes with LSL was greater than when either chlorine or chloramine with orthophosphate was used. For children tested after LSLs in their houses were replaced, those with partially replaced LSL were >3 times as likely to have BLLs ≥ 10 μg/dL versus children who never had LSLs. LSLs were a risk factor for elevated BLLs even when WASA met the EPA water action level. Changes in water disinfection can enhance the effect of LSLs and increase lead exposure. Partially replacing LSLs may not decrease the risk of elevated BLLs associated with LSL exposure. Copyright © 2010 Elsevier Inc. All rights reserved.
Leschinger, Tim; Wallraff, Christopher; Müller, Dirk; Hackenbroch, Matthias; Bovenschulte, Henning; Siewe, Jan
2017-01-01
External impingement tests are considered as being particularly reliable for identifying subacromial and coracoid shoulder impingement mechanisms. The purpose of the present study was to evaluate if these tests are likely to provoke an internal shoulder impingement mechanism which, in cases of a pathologic condition, can lead to a positive test result. In 37 subjects, the mechanical contact between the glenoid rim and the rotator cuff (RC) was measured quantitatively and qualitatively in external impingement test positions using an open MRI system. Mechanical contact of the supraspinatus with the posterosuperior glenoid was present in 30 subjects in the Neer test. In the Hawkins test, the subscapularis was in contact with the anterosuperior glenoid in 33 subjects and the supraspinatus in 18. In the horizontal impingement test, anterosuperior contact of the supraspinatus with the glenoid was identified in 35 subjects. The Neer, Hawkins, and horizontal impingement tests are likely to provoke the mechanism of an internal shoulder impingement. A posterosuperior internal impingement mechanism is being provoked predominately in the Neer test. The Hawkins test narrows the distance between the insertions of the subscapularis and supraspinatus and the anterosuperior labrum, which leads to an anterosuperior impingement mechanism.
An Insoluble Titanium-Lead Anode for Sulfate Electrolytes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferdman, Alla
2005-05-11
The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead compositemore » material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having optimized composition and structure were produced for testing in operating conditions of copper electrowinning and EMD production. Bench-scale, mini-pilot scale and pilot scale tests were performed. The test anodes were of both a plate design and a flow-through cylindrical design. The cylindrical anodes were composed of cylinders containing titanium inner rods and fitting over titanium-lead bushings. The cylindrical design allows the electrolyte to flow through the anode, which enhances diffusion of the electrolyte reactants. The cylindrical anodes demonstrate higher mass transport capabilities and increased electrical efficiency compared to the plate anodes. Copper electrowinning represents the primary target market for the titanium-lead anode. A full-size cylindrical anode performance in copper electrowinning conditions was monitored over a year. The test anode to cathode voltage was stable in the 1.8 to 2.0 volt range. Copper cathode morphology was very smooth and uniform. There was no measurable anode weight loss during this time period. Quantitative chemical analysis of the anode surface showed that the lead content after testing remained at its initial level. No lead dissolution or transfer from the anode to the product occurred.A key benefit of the titanium-lead anode design is that cobalt additions to copper electrolyte should be eliminated. Cobalt is added to the electrolyte to help stabilize the lead oxide surface of conventional lead anodes. The presence of the titanium intimately mixed with the lead should eliminate the need for cobalt stabilization of the lead surface. The anode should last twice as long as the conventional lead anode. Energy savings should be achieved due to minimizing and stabilizing the anode-cathode distance in the electrowinning cells. The anode is easily substitutable into existing tankhouses without a rectifier change.The copper electrowinning test data indicate that the titanium-lead anode is a good candidate for further testing as a possible replacement for a conventional lead anode. A key consideration is the cost. Titanium costs have increased. One of the ways to get the anode cost down is manufacturing the anodes with fewer cylinders. Additional prototypes having different number of cylinders were constructed for a long-term commercial testing in a circuit without cobalt. The objective of the testing is to evaluate the need for cobalt, investigate the effect of decreasing the number of cylinders on the anode performance, and to optimize further the anode design in order to meet the operating requirements, minimize the voltage, maximize the life of the anode, and to balance this against a reasonable cost for the anode. It is anticipated that after testing of the additional prototypes, a whole cell commercial test will be conducted to complete evaluation of the titanium-lead anode costs/benefits.« less
Ohno, Shotaro; Takahashi, Kana; Inoue, Aimi; Takada, Koki; Ishihara, Yoshiaki; Tanigawa, Masaru; Hirao, Kazuki
2017-12-01
This study aims to examine the smallest detectable change (SDC) and test-retest reliability of the Center for Epidemiologic Studies Depression Scale (CES-D), General Self-Efficacy Scale (GSES), and 12-item General Health Questionnaire (GHQ-12). We tested 154 young adults at baseline and 2 weeks later. We calculated the intra-class correlation coefficients (ICCs) for test-retest reliability with a two-way random effects model for agreement. We then calculated the standard error of measurement (SEM) for agreement using the ICC formula. The SEM for agreement was used to calculate SDC values at the individual level (SDC ind ) and group level (SDC group ). The study participants included 137 young adults. The ICCs for all self-reported outcome measurement scales exceeded 0.70. The SEM of CES-D was 3.64, leading to an SDC ind of 10.10 points and SDC group of 0.86 points. The SEM of GSES was 1.56, leading to an SDC ind of 4.33 points and SDC group of 0.37 points. The SEM of GHQ-12 with bimodal scoring was 1.47, leading to an SDC ind of 4.06 points and SDC group of 0.35 points. The SEM of GHQ-12 with Likert scoring was 2.44, leading to an SDC ind of 6.76 points and SDC group of 0.58 points. To confirm that the change was not a result of measurement error, a score of self-reported outcome measurement scales would need to change by an amount greater than these SDC values. This has important implications for clinicians and epidemiologists when assessing outcomes. © 2017 John Wiley & Sons, Ltd.
Chromosome Connections: Compelling Clues to Common Ancestry
ERIC Educational Resources Information Center
Flammer, Larry
2013-01-01
Students compare banding patterns on hominid chromosomes and see striking evidence of their common ancestry. To test this, human chromosome no. 2 is matched with two shorter chimpanzee chromosomes, leading to the hypothesis that human chromosome 2 resulted from the fusion of the two shorter chromosomes. Students test that hypothesis by looking for…
Optical fibers for FTTH application
NASA Astrophysics Data System (ADS)
Guzowski, Bartlomiej; Tosik, Grzegorz; Lisik, Zbigniew; Bedyk, Michal; Kubiak, Andrzej
2013-07-01
In this paper the specifics of FTTH (Fiber To The Home) networks in terms of requirements for optical fibers has been presented. Optical fiber samples used in FTTH applications acquired from the worldwide leading manufacturers were subjected to small diameter mandrel wraps tests. The detailed procedures of performed tests and the measurement results has been presented.
Stereotype Threat Effects on African American Children in an Urban Elementary School
ERIC Educational Resources Information Center
Wasserberg, Martin J.
2014-01-01
This study investigated whether a diagnostic testing condition leads to stereotype threat effects for African American children (n = 198) at an urban elementary school. Results indicated that presenting a reading test as diagnostic of abilities hindered the performance of African American children aware of racial stereotypes but not of those…
Algorithm and code development for unsteady three-dimensional Navier-Stokes equations
NASA Technical Reports Server (NTRS)
Obayashi, Shigeru
1991-01-01
A streamwise upwind algorithm for solving the unsteady 3-D Navier-Stokes equations was extended to handle the moving grid system. It is noted that the finite volume concept is essential to extend the algorithm. The resulting algorithm is conservative for any motion of the coordinate system. Two extensions to an implicit method were considered and the implicit extension that makes the algorithm computationally efficient is implemented into Ames's aeroelasticity code, ENSAERO. The new flow solver has been validated through the solution of test problems. Test cases include three-dimensional problems with fixed and moving grids. The first test case shown is an unsteady viscous flow over an F-5 wing, while the second test considers the motion of the leading edge vortex as well as the motion of the shock wave for a clipped delta wing. The resulting algorithm has been implemented into ENSAERO. The upwind version leads to higher accuracy in both steady and unsteady computations than the previously used central-difference method does, while the increase in the computational time is small.
[Do we always correctly interpret the results of statistical nonparametric tests].
Moczko, Jerzy A
2014-01-01
Mann-Whitney, Wilcoxon, Kruskal-Wallis and Friedman tests create a group of commonly used tests to analyze the results of clinical and laboratory data. These tests are considered to be extremely flexible and their asymptotic relative efficiency exceeds 95 percent. Compared with the corresponding parametric tests they do not require checking the fulfillment of the conditions such as the normality of data distribution, homogeneity of variance, the lack of correlation means and standard deviations, etc. They can be used both in the interval and or-dinal scales. The article presents an example Mann-Whitney test, that does not in any case the choice of these four nonparametric tests treated as a kind of gold standard leads to correct inference.
Determining Childhood Blood Lead Level Screening Compliance Among Physicians.
Haboush-Deloye, Amanda; Marquez, Erika R; Gerstenberger, Shawn L
2017-08-01
Childhood Lead Poisoning Prevention Programs throughout the U.S. have addressed childhood lead poisoning by implementing primary and secondary prevention efforts. While many programs have helped increase screening rates, in some states children under the age of six still have not been tested for lead. This study aims to identify the barriers to childhood blood lead testing and develop a strategy to increase the number of children tested. Clark County physicians who work with children six and under were surveyed about blood lead level (BLL) testing practices, particularly, adherence to Centers for Disease Control and Prevention (CDC) guidelines, and parental compliance with orders to have their children tested to determine their blood lead levels. In addition, select in-person interviews were conducted with physicians who reported high parental compliance to identify best practices and barriers. Of the 77 physicians that provided data, 48% indicated they did not follow CDC guideline compared to 52% who follow guidelines. 18 of the 30 (or 60%) physicians reported more than 80% of parents complied with doctor recommended BLL testing. Twelve physicians identified cost, lack of insurance, and absence of symptomology as persistent barriers to lead screening. This study identified barriers to childhood lead screening including inadequate parental adherence to physician-ordered screenings and physician non-compliance with screening recommendations are two primary contributors. Addressing these issues could increase screening in children and reduce the risk of lead poisoning.
NASA Technical Reports Server (NTRS)
Melis, Matthew E.
2007-01-01
On February 1, 2003, the Space Shuttle Columbia broke apart during reentry, resulting in loss of the vehicle and its seven crewmembers. For the next several months, an extensive investigation of the accident ensued involving a nationwide team of experts from NASA, industry, and academia, spanning dozens of technical disciplines. The Columbia Accident Investigation Board (CAIB), a group of experts assembled to conduct an investigation independent of NASA, concluded in August, 2003 that the most likely cause of the loss of Columbia and its crew was a breach in the left wing leading edge Reinforced Carbon-Carbon (RCC) thermal protection system initiated by the impact of thermal insulating foam that had separated from the orbiters external fuel tank 81 seconds into the mission's launch. During reentry, this breach allowed superheated air to penetrate behind the leading edge and erode the aluminum structure of left wing, which ultimately led to the breakup of the orbiter. The findings of the CAIB were supported by ballistic impact tests, which simulated the physics of External Tank Foam impact on the RCC wing leading edge material. These tests ranged from fundamental material characterization tests to full-scale Orbiter Wing Leading Edge tests. Following the accident investigation, NASA spent the next 18 months focused on returning the shuttle safely to flight. In order to fully evaluate all potential impact threats from the many debris sources on the Space Shuttle during ascent, NASA instituted a significant impact testing program. The results from these tests led to the validation of high-fidelity computer models, capable of predicting actual or potential Shuttle impact events, were used in the certification of STS-114, NASA s Return to Flight Mission, as safe to fly. This presentation will provide a look into the inner workings of the Space Shuttle and a behind the scenes perspective on the impact analysis and testing done for the Columbia Accident Investigation and NASA's Return to Flight programs. In addition, highlights from recent Shuttle missions are presented.
NASA Technical Reports Server (NTRS)
Sharpe, David L.
1986-01-01
A small scale, 1.92 m diam, torsionally soft, hingeless helicopter rotor was investigated in hover to determine isolated rotor stability characteristics. The two-bladed, untwisted rotor was tested on a rigid test stand at tip speeds up to 101 m/sec. The rotor mode of interest is the lightly damped lead-lag mode. The dimensionless lead-lag frequency of the mode is approximately 1.5 at the highest tip speed. The hub was designed to allow variation in precone, blade droop, pitch control stiffness, and blade pitch angle. Measurements of modal frequency and damping were obtained for several combinations of these hub parameters at several values of rotor speed. Steady blade bending moments were also measured. The lead-lag damping measurements were found to agree well with theoretical predictions for low values of blade pitch angle. The test data confirmed the predicted effects of precone, droop, and pitch control stiffness parameters on lead-lag damping. The correlation between theory and experiment was found to be poor for the mid-to-high range of pitch angles where the theory substantially overpredicted the experimental lead-lag damping. The poor correlation in the mid-to-high blade pitch angle range is attributed to low Reynolds number nonlinear aerodynamics effects not included in the theory. The experimental results also revealed an asymmetry in lead-lag damping between positive and negative thrust conditions.
NASA Astrophysics Data System (ADS)
Fegan, S.; Auffray, E.; Battaglieri, M.; Buchanan, E.; Caiffi, B.; Celentano, A.; Colaneri, L.; D`Angelo, A.; De Vita, R.; Dormenev, V.; Fanchini, E.; Lanza, L.; Novotny, R. W.; Parodi, F.; Rizzo, A.; Sokhan, D.; Tarasov, I.; Zonta, I.
2015-07-01
The well-established technology of electromagnetic calorimetry using Lead Tungstate crystals has recently seen an upheaval, with the closure of one of the most experienced large-scale suppliers of such crystals, the Bogoroditsk Technical Chemical Plant (BTCP), which was instrumental in the development of mass production procedures for PWO-II, the current benchmark for this scintillator. Obtaining alternative supplies of Lead Tungstate crystals matching the demanding specifications of contemporary calorimeter devices now presents a significant challenge to detector research and development programmes. In this paper we describe a programme of assessment carried out for the selection, based upon the performance under irradiation, of Lead Tungstate crystals for use in the Forward Tagger device, part of the CLAS12 detector in Hall B at Jefferson Lab. The crystals tested were acquired from SICCAS, the Shanghai Institute of Ceramics, Chinese Academy of Sciences. The tests performed are intended to maximise the performance of the detector within the practicalities of the crystal manufacturing process. Results of light transmission, before and after gamma ray irradiation, are presented and used to calculate dk, the induced radiation absorption coefficient, at 420 nm, the peak of the Lead Tungstate emission spectrum. Results for the SICCAS crystals are compared with identical measurements carried out on Bogoroditsk samples, which were acquired for the Forward Tagger development program before the closure of the facility. Also presented are a series of tests performed to determine the feasibility of recovering radiation damage to the crystals using illumination from an LED, with such illumination available in the Forward Tagger from a light monitoring system integral to the detector.
Test results of a 20 kA high temperature superconductor current lead using REBCO tapes
NASA Astrophysics Data System (ADS)
Heller, R.; Fietz, W. H.; Gröner, F.; Heiduk, M.; Hollik, M.; Lange, C.; Lietzow, R.
2018-05-01
The Karlsruhe Institute of Technology has developed a 20 kA high temperature superconductor (HTS) current lead (CL) using the second generation material REBCO, as industry worldwide concentrate on the production of this material. The aim was to demonstrate the possibility of replacing the Bi-2223/AgAu tapes by REBCO tapes, while for easy comparison of results, all other components are copies of the 20 kA HTS CL manufactured for the satellite tokamak JT-60SA. After the manufacture of all CL components including the newly developed REBCO module, the assembly of the CL has been executed at KIT and an experiment has been carried out in the CuLTKa test facility where the REBCO CL was installed and connected to a JT-60SA CL via a superconducting bus bar. The experiment covers steady state operation up to 20 kA, pulsed operation, measurement of the heat load at 4.5 K end, loss-of-flow-accident simulations, and quench performance studies. Here the results of these tests are reported and directly compared to those of the JT-60SA CL.
Investigation of leading-edge flap performance on delta and double-delta wings at supersonic speeds
NASA Technical Reports Server (NTRS)
Covell, Peter F.; Wood, Richard M.; Miller, David S.
1987-01-01
An investigation of the aerodynamic performance of leading-edge flaps on three clipped delta and three clipped double-delta wing planforms with aspect ratios of 1.75, 2.11, and 2.50 was conducted in the Langley Unitary Plan Wind Tunnel at Mach numbers of 1.60, 1.90, and 2.16. A primary set of fullspan leading-edge flaps with similar root and tip chords were investigated on each wing, and several alternate flap planforms were investigated on the aspect-ratio-1.75 wings. All leading-edge flap geometries were effective in reducing the drag at lifting conditions over the range of wing aspect ratios and Mach numbers tested. Application of a primary flap resulted in better flap performance with the double-delta planform than with the delta planform. The primary flap geometry generally yielded better performance than the alternate flap geometries tested. Trim drag due to flap-induced pitching moments was found to reduce the leading-edge flap performance more for the delta planform than for the double-delta planform. Flow-visualization techniques showed that leading-edge flap deflection reduces crossflow shock-induced separation effects. Finally, it was found that modified linear theory consistently predicts only the effects of leading-edge flap deflection as related to pitching moment and lift trends.
Lead-contaminated imported tamarind candy and children's blood lead levels.
Lynch, R A; Boatright, D T; Moss, S K
2000-01-01
In 1999, an investigation implicated tamarind candy as the potential source of lead exposure for a child with a significantly elevated blood lead level (BLL). The Oklahoma City-County Health Department tested two types of tamarind suckers and their packaging for lead content. More than 50% of the tested suckers exceeded the US Food and Drug Administration (FDA) Level of Concern for lead in this type of product. The authors calculated that a child consuming one-quarter to one-half of either of the two types of suckers in a day would exceed the maximum FDA Provis onal Tolerable Intake for lead. High lead concentrations in the two types of wrappers suggested leaching as a potential source of contamination. The authors used the Environmental Protection Agency's Integrated Exposure Uptake Biokinetic (IEUBK) model to predict the effects of consumption of contaminated tamarind suckers on populat on BLLs. The IEUBK model predicted that consumption of either type of sucker at a rate of one per day would result in dramatic increases in mean BLLs for children ages 6-84 months in Oklahoma and in the percentage of children wth elevated BLLs (> or =10 micrograms per deciliter [microg/dL]). The authors conclude that consumption of these products represents a potential public health threat. In addition, a history of lead contamination in imported tamarind products suggests that import control measures may not be completely effective in preventing additional lead exposure. PMID:11354337
Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph
2010-09-01
The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P < 0.01). There was no significant difference between coagulated and uncoagulated samples run by atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.
Automated Lead Optimization of MMP-12 Inhibitors Using a Genetic Algorithm.
Pickett, Stephen D; Green, Darren V S; Hunt, David L; Pardoe, David A; Hughes, Ian
2011-01-13
Traditional lead optimization projects involve long synthesis and testing cycles, favoring extensive structure-activity relationship (SAR) analysis and molecular design steps, in an attempt to limit the number of cycles that a project must run to optimize a development candidate. Microfluidic-based chemistry and biology platforms, with cycle times of minutes rather than weeks, lend themselves to unattended autonomous operation. The bottleneck in the lead optimization process is therefore shifted from synthesis or test to SAR analysis and design. As such, the way is open to an algorithm-directed process, without the need for detailed user data analysis. Here, we present results of two synthesis and screening experiments, undertaken using traditional methodology, to validate a genetic algorithm optimization process for future application to a microfluidic system. The algorithm has several novel features that are important for the intended application. For example, it is robust to missing data and can suggest compounds for retest to ensure reliability of optimization. The algorithm is first validated on a retrospective analysis of an in-house library embedded in a larger virtual array of presumed inactive compounds. In a second, prospective experiment with MMP-12 as the target protein, 140 compounds are submitted for synthesis over 10 cycles of optimization. Comparison is made to the results from the full combinatorial library that was synthesized manually and tested independently. The results show that compounds selected by the algorithm are heavily biased toward the more active regions of the library, while the algorithm is robust to both missing data (compounds where synthesis failed) and inactive compounds. This publication places the full combinatorial library and biological data into the public domain with the intention of advancing research into algorithm-directed lead optimization methods.
Automated Lead Optimization of MMP-12 Inhibitors Using a Genetic Algorithm
2010-01-01
Traditional lead optimization projects involve long synthesis and testing cycles, favoring extensive structure−activity relationship (SAR) analysis and molecular design steps, in an attempt to limit the number of cycles that a project must run to optimize a development candidate. Microfluidic-based chemistry and biology platforms, with cycle times of minutes rather than weeks, lend themselves to unattended autonomous operation. The bottleneck in the lead optimization process is therefore shifted from synthesis or test to SAR analysis and design. As such, the way is open to an algorithm-directed process, without the need for detailed user data analysis. Here, we present results of two synthesis and screening experiments, undertaken using traditional methodology, to validate a genetic algorithm optimization process for future application to a microfluidic system. The algorithm has several novel features that are important for the intended application. For example, it is robust to missing data and can suggest compounds for retest to ensure reliability of optimization. The algorithm is first validated on a retrospective analysis of an in-house library embedded in a larger virtual array of presumed inactive compounds. In a second, prospective experiment with MMP-12 as the target protein, 140 compounds are submitted for synthesis over 10 cycles of optimization. Comparison is made to the results from the full combinatorial library that was synthesized manually and tested independently. The results show that compounds selected by the algorithm are heavily biased toward the more active regions of the library, while the algorithm is robust to both missing data (compounds where synthesis failed) and inactive compounds. This publication places the full combinatorial library and biological data into the public domain with the intention of advancing research into algorithm-directed lead optimization methods. PMID:24900251
1996-10-01
Document provides a Test Plan for studying and improving techniques tor remediating lead contaminated soils using Phytoremediation . Test Plan for study examining the uptake of lead by Plants in contaminated soils.
1996-10-01
Document provides a Test Plan for studying and improving techniques tor remediating lead contaminated soils using Phytoremediation . Test Plan for study examining the uptake of lead by Plants in contaminated soils.
Green, R E; Pain, D J
2012-11-01
We estimate potential risks to human health in the UK from dietary exposure to lead from wild gamebirds killed by shooting. The main source of exposure to lead in Europe is now dietary. We used data on lead concentrations in UK gamebirds, from which gunshot had been removed following cooking to simulate human exposure to lead. We used UK food consumption and lead concentration data to evaluate the number of gamebird meals consumed weekly that would be expected, based upon published studies, to result in changes, over and above those resulting from exposure to lead in the base diet, in intelligence quotient (IQ), Systolic Blood Pressure and chronic kidney disease (CKD) considered in a recent opinion of the European Food Safety Authority (EFSA) to be significant at a population level and also in SAT test scores and in rates of spontaneous abortion. We found the consumption of <1 meal of game a week may be associated with a one point reduction in IQ in children and 1.2-6.5 gamebird meals per week may be associated with the other effects. These results should help to inform the development of appropriate responses to the risks from ingesting lead from ammunition in game in the UK and European Union (EU). Copyright © 2012 Elsevier Ltd. All rights reserved.
... important in testing for autoimmune diseases, especially systemic lupus erythematosus . Low levels of C1-INH can lead to a condition called angioedema . Angioedema results in sudden swelling of the tissues of the ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pytel, K.; Mieleszczenko, W.; Lechniak, J.
2010-03-01
The presented paper contains neutronic and thermal-hydraulic (for steady and unsteady states) calculation results prepared to support annex to Safety Analysis Report for MARIA reactor in order to obtain approval for program of testing low-enriched uranium (LEU) lead test fuel assemblies (LTFA) manufactured by CERCA. This includes presentation of the limits and operational constraints to be in effect during the fuel testing investigations. Also, the scope of testing program (which began in August 2009), including additional measurements and monitoring procedures, is described.
Solomon, A J; Moubarak, J B; Drood, J M; Tracy, C M; Karasik, P E
1999-10-01
Defibrillator generator changes are frequently performed on patients with an implantable cardioverter defibrillator in an abdominal pocket. These patients usually have epicardial patches or older endocardial lead systems. At the time of a defibrillator generator change defibrillation may be unsuccessful as a result of lead failure. We tested the hypothesis that an active can defibrillator implanted in the abdominal pocket could replace a non-functioning endocardial lead or epicardial patch. An abdominal defibrillator generator change was performed in 10 patients, (mean age = 67 +/- 13 years, nine men). Initially, a defibrillation threshold (DFT) was obtained using a passive defibrillator and the chronic endocardial or epicardial lead system. DFTs were then performed using an active can emulator and one chronic lead to simulate endocardial or epicardial lead failure. We tested 30 lead configurations (nine endocardial and 21 epicardial). Although a DFT of 7.3 +/- 4.2 joules was obtained with the intact chronic lead system, the active can emulator and one endocardial or epicardial lead still yielded an acceptable DFT of 19.9 +/- 6.1 joules. In addition, a successful implant (DFT < or = 24 joules) could have been accomplished in 28 of 30 (93%) lead configurations. An active can defibrillator in an abdominal pocket may allow for a successful generator change in patients with defibrillator lead malfunction. This would be simpler than abandoning the abdominal implant and moving to a new pectoral device and lead or tunnelling a new endocardial electrode. However, loss of defibrillation capability with a particular complex lead may be a warning of impending loss of other functions (eg. sensing and/or pacing).
Effect of leading-edge load constraints on the design and performance of supersonic wings
NASA Technical Reports Server (NTRS)
Darden, C. M.
1985-01-01
A theoretical and experimental investigation was conducted to assess the effect of leading-edge load constraints on supersonic wing design and performance. In the effort to delay flow separation and the formation of leading-edge vortices, two constrained, linear-theory optimization approaches were used to limit the loadings on the leading edge of a variable-sweep planform design. Experimental force and moment tests were made on two constrained camber wings, a flat uncambered wing, and an optimum design with no constraints. Results indicate that vortex strength and separation regions were mildest on the severely and moderately constrained wings.
NASA Technical Reports Server (NTRS)
Stimpert, D. L.
1975-01-01
Test results of the LF336/E statorless lift fan with serrated and unserrated rotor leading edges are presented. Fan broadband noise reductions from 2 to 5 dB were achieved in the forward quadrant at frequencies from 100 to 2500 Hz. Broadband noise near and above the blade passing frequency was reduced only at angles of 80 to 100 degrees.
Krasteva, Vessela; Jekova, Irena; Schmid, Ramun
2018-01-01
This study aims to validate the 12-lead electrocardiogram (ECG) as a biometric modality based on two straightforward binary QRS template matching characteristics. Different perspectives of the human verification problem are considered, regarding the optimal lead selection and stability over sample size, gender, age, heart rate (HR). A clinical 12-lead resting ECG database, including a population of 460 subjects with two-session recordings (>1 year apart) is used. Cost-effective strategies for extraction of personalized QRS patterns (100ms) and binary template matching estimate similarity in the time scale (matching time) and dissimilarity in the amplitude scale (mismatch area). The two-class person verification task, taking the decision to validate or to reject the subject identity is managed by linear discriminant analysis (LDA). Non-redundant LDA models for different lead configurations (I,II,III,aVF,aVL,aVF,V1-V6) are trained on the first half of 230 subjects by stepwise feature selection until maximization of the area under the receiver operating characteristic curve (ROC AUC). The operating point on the training ROC at equal error rate (EER) is tested on the independent dataset (second half of 230 subjects) to report unbiased validation of test-ROC AUC and true verification rate (TVR = 100-EER). The test results are further evaluated in groups by sample size, gender, age, HR. The optimal QRS pattern projection for single-lead ECG biometric modality is found in the frontal plane sector (60°-0°) with best (Test-AUC/TVR) for lead II (0.941/86.8%) and slight accuracy drop for -aVR (-0.017/-1.4%), I (-0.01/-1.5%). Chest ECG leads have degrading accuracy from V1 (0.885/80.6%) to V6 (0.799/71.8%). The multi-lead ECG improves verification: 6-chest (0.97/90.9%), 6-limb (0.986/94.3%), 12-leads (0.995/97.5%). The QRS pattern matching model shows stable performance for verification of 10 to 230 individuals; insignificant degradation of TVR in women by (1.2-3.6%), adults ≥70 years (3.7%), younger <40 years (1.9%), HR<60bpm (1.2%), HR>90bpm (3.9%), no degradation for HR change (0 to >20bpm).
TQAP for Verification of Qualitative Lead Test Kits
There are lead-based paint test kits available to help home owners and contractors identify lead-based paint hazards before any Renovation, Repair, and Painting (RRP) activities take place so that proper health and safety meaures can be enacted. However, many of these test kits ...
Transonic Reynolds Number and Leading-Edge Bluntness Effects on a 65 deg Delta Wing
NASA Technical Reports Server (NTRS)
Luckring, J. M.
2003-01-01
A 65 degree delta wing has been tested in the National Transonic Facility (NTF) at mean aerodynamic chord Reynolds numbers from 6 million to 120 million at subsonic and transonic speeds. The configuration incorporated a systematic variation of the leading edge bluntness. The analysis for this paper is focused on the Reynolds number and bluntness effects at transonic speeds (M = 0.85) from this data set. The results show significant effects of both these parameters on the onset and progression of leading edge vortex separation.
Reynolds Number and Leading-Edge Bluntness Effects on a 65 Deg Delta Wing
NASA Technical Reports Server (NTRS)
Luckring, J. M.
2002-01-01
A 65 deg delta wing has been tested in the National Transonic Facility (NTF) at mean aerodynamic chord Reynolds numbers from 6 million to 120 million at subsonic and transonic speeds. The configuration incorporated systematic variation of the leading edge bluntness. The analysis for this paper is focused on the Reynolds number and bluntness effects at subsonic speeds (M = 0.4) from this data set. The results show significant effects of both these parameters on the onset and progression of leading-edge vortex separation.
Transonic Reynolds Number and Leading-Edge Bluntness Effects on a 65 deg Delta Wing
NASA Technical Reports Server (NTRS)
Luckring, J. M.
2003-01-01
A 65 deg delta wing has been tested in the National Transonic Facility (NTF) at mean aerodynamic chord Reynolds numbers from 6 million to 120 million at subsonic and transonic speeds. The configuration incorporated a systematic variation of the leading edge bluntness. The analysis for this paper is focused on the Reynolds number and bluntness effects at transonic speeds (M = 0.85) from this data set. The results show significant effects of both these parameters on the onset and progression of leading- edge vortex separation.
Reynolds Number and Leading-Edge Bluntness Effects on a 65 deg Delta Wing
NASA Technical Reports Server (NTRS)
Luckring, J. M.
2002-01-01
A 65 degree delta wing has been tested in the National Transonic Facility (NTF) at mean aerodynamic chord Reynolds numbers from 6 million to 120 million at subsonic and transonic speeds. The configuration incorporated systematic variation of the leading edge bluntness. The analysis for this paper is focused on the Reynolds number and bluntness effects at subsonic speeds (M = 0.4) from this data set. The results show significant effects of both these parameters on the onset and progression of leading-edge vortex separation.
Transonic Reynolds Number and Leading-Edge Bluntness Effects on a 65 deg Delta Wing
NASA Technical Reports Server (NTRS)
Luckring, J. M.
2003-01-01
A 65 deg delta wing has been tested in the National Transonic Facility (NTF) at mean aerodynamic chord Reynolds numbers from 6 million to 120 million at subsonic and transonic speeds. The configuration incorporated a systematic variation of the leading edge bluntness. The analysis for this paper is focused on the Reynolds number and bluntness effects at transonic speeds (M=0.85) from this data set. The results show significant effects of both these parameters on the onset and progression of leading-edge vortex separation.
NASA Technical Reports Server (NTRS)
Hahne, David E.; Glaab, Louis J.
1999-01-01
An investigation was performed to evaluate leading-and trailing-edge flap deflections for optimal aerodynamic performance of a High-Speed Civil Transport concept during takeoff and approach-to-landing conditions. The configuration used for this study was designed by the Douglas Aircraft Company during the 1970's. A 0.1-scale model of this configuration was tested in the Langley 30- by 60-Foot Tunnel with both the original leading-edge flap system and a new leading-edge flap system, which was designed with modem computational flow analysis and optimization tools. Leading-and trailing-edge flap deflections were generated for the original and modified leading-edge flap systems with the computational flow analysis and optimization tools. Although wind tunnel data indicated improvements in aerodynamic performance for the analytically derived flap deflections for both leading-edge flap systems, perturbations of the analytically derived leading-edge flap deflections yielded significant additional improvements in aerodynamic performance. In addition to the aerodynamic performance optimization testing, stability and control data were also obtained. An evaluation of the crosswind landing capability of the aircraft configuration revealed that insufficient lateral control existed as a result of high levels of lateral stability. Deflection of the leading-and trailing-edge flaps improved the crosswind landing capability of the vehicle considerably; however, additional improvements are required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... segments on which test leads were not required by regulations in effect before January 28, 2002. (b... or slack so backfilling will not unduly stress or break the lead and the lead will otherwise remain mechanically secure and electrically conductive. (3) Prevent lead attachments from causing stress...
Testing for lead in toys at day care centers.
Sanders, Martha; Stolz, Julie; Chacon-Baker, Ashley
2013-01-01
Exposure to lead-based paint or material has been found to impact children's cognitive and behavioral development at blood lead levels far below current standards. The purpose of the project was to screen for lead in toy items in daycare centers in order to raise awareness of inside environmental lead exposures and minimize lead-based exposures for children. Occupational therapy students in a service learning class tested for lead in ten daycare or public centers using the XRF Thermo Scientific Niton XL3t, a method accepted by the Consumer Product Safety Commission (CPSC). A total of 460 items were tested over a two-month period for an average of 66 toys per setting. Fifty six (56) items tested > 100 ppm, which represented 12% of the entire sample. Items with high lead levels included selected toys constructed with lead-based paint, lead metals, plastics using lead as a color enhancer, and decorative objects. While the actual number of lead-based products is small, the cumulative exposure or habitual use may pose an unnecessary risk to children. Indoor exposures occurred for all day care centers regardless of socio-economic levels. Recommendations to minimize exposures are provided.
ERIC Educational Resources Information Center
Garcia, Ernest
2015-01-01
Other than being African American, little is known of Larry, the lead plaintiff in the legal case known as "Larry P. v. Riles" in 1971, which banned the use of standardized intelligence testing on African-American students in the State of California. As a result of such intelligence testing, Larry was diagnosed as being mildly mentally…
Basic problems of serological laboratory diagnosis.
Fierz, Walter
2004-01-01
Serological laboratory diagnosis of infectious diseases is inflicted with several kinds of basic problems. One difficulty relates to the fact that the serological diagnosis of infectious diseases is double indirect: The first indirect aim in diagnosing an infectious disease is to identify the microbial agent that caused the disease. The second indirect aim is to identify this infectious agent by measuring the patient's immune response to the potential agent. Thus, the serological test is neither measuring directly disease nor the cause of the disease, but the patient's immune system. The latter poses another type of problem, because each person's immune system is unique. The immune response to an infectious agent is usually of polyclonal nature, and the exact physicochemical properties of antibodies are unique for each clone of antibody. The clonal makeup and composition and, therefore, the way an individual's immune system sees an infectious agent, depends not only on the genetic background of the person but also on the individual experience from former encounters with various infectious agents. In consequence, the reaction of a patient's serum in an analytical system is not precisely predictable. Also, the antigenic makeup of an infectious agent is not always foreseeable. Antigenic variations leading to different serotypes is a quite common phenomenon. Altogether, these biological problems lead to complexities in selecting the appropriate tests and strategies for testing, in interpreting the results, and in standardizing serological test systems. For that reason, a close collaboration of the laboratory with the clinic is mandatory to avoid erroneous conclusions from serological test results, which might lead to wrong decisions in patient care.
Predictive testing for Huntington's disease: relationship with partners after testing.
Decruyenaere, M; Evers-Kiebooms, G; Cloostermans, T; Boogaerts, A; Demyttenaere, K; Dom, R; Fryns, J P
2004-01-01
This study focuses on the partner relationship of tested persons, 5 years after their predictive test result for Huntington's disease (HD). We describe changes in marital status, quality of the relationship, and perceived changes in the relationship. Twenty-six carriers, 14 of their partners, 33 non-carriers, and 17 of their partners participated in the study. Qualitative and quantitative methods were used. For the majority of tested persons (about 70%), the marital status was unchanged 5 years post test. Overall, carriers rated the quality of the relationship higher than their partners did and they perceived more positive changes. Qualitative data show that a test result leading to changed roles may induce significant marital distress. Another consequence of the test may be the changes in dynamics in asymptomatic carrier couples. A pre-test discussion of the possible impact of the test result on the relationship should result in a better preparation for and more understanding of the reactions after testing. Counselling after testing should stimulate an open communication between partners with consideration of needs and anxieties of both partners.
2013-01-01
Background The phasing out of lead from gasoline has resulted in a significant decrease in blood lead levels (BLLs) in children during the last two decades. Tetraethyl lead was phased out in DRC in 2009. The objective of this study was to test for reduction in pediatric BLLs in Kinshasa, by comparing BLLs collected in 2011 (2 years after use of leaded gasoline was phased out) to those collected in surveys conducted in 2004 and 2008 by Tuakuila et al. (when leaded gasoline was still used). Methods We analyzed BLLs in a total of 100 children under 6 years of age (Mean ± SD: 2.9 ± 1.6 age, 64% boys) using inductively coupled argon plasma mass spectrometry (ICP – MS). Results The prevalence of elevated BLLs (≥ 10 μg/dL) in children tested was 63% in 2004 [n = 100, GM (95% CI) = 12.4 μg/dL (11.4 – 13.3)] and 71% in 2008 [(n = 55, GM (95% CI) = 11.2 μg/dL (10.3 – 14.4)]. In the present study, this prevalence was 41%. The average BLLs for the current study population [GM (95% CI) = 8.7 μg/dL (8.0 – 9.5)] was lower than those found by Tuakuila et al. (F = 10.38, p <0.001) as well as the CDC level of concern (10 μ/dL), with 3% of children diagnosed with BLLs ≥ 20 μg/dL. Conclusion These results demonstrate a significant success of the public health system in Kinshasa, DRC-achieved by the removal of lead from gasoline. However, with increasing evidence that adverse health effects occur at BLLs < 10 μg/dL and no safe BLLs in children has been identified, the BLLs measured in this study continue to constitute a major public health concern for Kinshasa. The emphasis should shift to examine the contributions of non-gasoline sources to children’s BLLs: car batteries recycling in certain residences, the traditional use of fired clay for the treatment of gastritis by pregnant women and leaded paint. PMID:23556999
Tang, Jie; Xue, Qiang; Chen, Honghan; Li, Wenting
2017-05-01
High concentrations of ammonium sulfate, often used in the in situ mining process, can result in a decrease of pH in the environment and dissolution of rare earth metals. Ammonium sulfate can also cause desorption of toxic heavy metals, leading to environmental and human health implications. In this study, the desorption behavior and fraction changes of lead in the ion-absorbed rare earth ore were studied using batch desorption experiments and column leaching tests. Results from batch desorption experiments showed that the desorption process of lead included fast and slow stages and followed an Elovich model well. The desorption rate and the proportion of lead content in the solution to the total lead in the soil were observed to increase with a decrease in the initial pH of the ammonium sulfate solution. The lead in soil included an acid-extractable fraction, reducible fraction, oxidizable fraction, and a residual fraction, with the predominant fractions being the reducible and acid-extractable fractions. Ninety-six percent of the extractable fraction in soil was desorbed into solution at pH = 3.0, and the content of the reducible fraction was observed to initially increase (when pH >4.0) and then decrease (when pH <4.0) with a decrease in pH. Column leaching tests indicated that the content of lead in the different fractions of soil followed the trend of reducible fraction > oxidizable fraction > acid-extractable fraction > residual fraction after the simulating leaching mining process. The change in pH was also found to have a larger influence on the acid-extractable and reducible fractions than the other two fractions. The proportion of the extractable fraction being leached was ca. 86%, and the reducible fraction was enriched along the migration direction of the leaching liquid. These results suggest that certain lead fractions may desorb again and contaminate the environment via acid rain, which provides significant information for environmental assessment and remediation after mining process. Graphical abstract ᅟ.
[Evaluation of cadmium, mercury and lead intake with reproduced weekly food rations].
Marzec, Z; Buliński, R
1991-01-01
In Lublin, Olsztyn, Poznań, Warszawa and Wrocław, weekly food rations characteristic of families other than those of manual workers, with medium incomes, were reproduced. Food rations comprised ca. 90 food products whose average weekly intakes were established consistently with the results of questionnaires of the Chief Census Bureau. Namely, from these results we calculated and prepared the average weekly food rations (from 11 470 g to 14 732 g), in which cadmium, mercury and lead were assayed by the ASA method. These average food rations afforded weekly intakes of 105-147 micrograms Cd, 441-931 micrograms Pb and 50.5-119.0 micrograms Hg. According to these results, the average food rations from the above-mentioned cities are moderately contaminated with the heavy metals tested, because in no case 50% of the provisional tolerable weekly intake (PTWI) were exceeded. The present results are lower than those obtained in the same year for families of manual workers; this is probably due to the fact that in the families of manual workers, as compared with other families, the weight of meals is usually higher. It is noteworthy that in the cities with greater numbers of industrial plants the contents of the metals tested, particularly of mercury and lead, in food are higher.
NASA Astrophysics Data System (ADS)
Mahin Shirazi, Sam
Accelerated thermal cycling (ATC) tests are the most commonly used tests for the thermo-mechanical performance assessment of microelectronics assemblies. Currently used reliability models have failed to incorporate the microstructural dependency of lead free solder joint behavior and its microstructure evolution during cycling. Thus, it is essential to have a mechanistic understanding of the effect of cycling parameters on damage evolution and failure of lead free solder joints in ATC. Recrystallization has been identified as the damage rate controlling mechanism in ATC. Usually it takes 1/3 of life for completion of recrystallization regardless of cycling parameters. Thus, the life of the solder joints can be predicted by estimating global recrystallization. The objective of the first part of the study was to examine whether the damage scenario applies in service is the same as the harsh thermal cycling tests (i.e. 0/100 °C and -40/125 °C) commonly used in industry. Microstructure analysis results on a variety of lead free solder SnAgCu assemblies subjected to the both harsh (0/100 °C) and mild (20/80 °C) ATC confirmed similar failure mechanism under the both testing conditions. Sn grain morphology (interlaced versus beach ball) has a significant effect on the thermo-mechanical performance (and thus the model) of the lead free solder joints. The longer thermal cycling lifetime observed in the interlaced solder joints subjected to the ATC compared to the beach ball structure was correlated to the different initial microstructure and the microstructure evolution during cycling. For the modeling proposes, the present study was focused on Sn-Ag-Cu solder joints with either a single Sn grain or beach ball structure. Microstructural analysis results of the simulated thermal cycling experiment revealed that, the life can be approximated as determined by the accumulation of a certain amount of work during the high temperature dwells. Finally the effect of precipitates spacing on acceleration factor was investigated. Results indicated that a smaller initial precipitate spacing would tend to result in a longer life in mild thermal cycling/service (where there is lower stresses). Accordingly, it is essential to incorporate the dependence of damage rate (i.e. recrystallization) on precipitate coarsening in any predictions.
Experimental Research on Air Propellers III
NASA Technical Reports Server (NTRS)
Durand, W F; Lesley, E P
1920-01-01
Report presents the results of wind tunnel tests of propellers that examined the influence of the following characteristics: (1) nominal pitch ratio 1.3 combined with a certain number of the more common or standard forms and proportions; (2) driving face slightly rounded or convex; (3) change in the location of the maximum thickness ordinate of the blade section; (4) pushing forward the leading edge of the blade, thus giving a rounded convex surface on the leading side of the driving face. (5) a series of values for the constant "angle of attack" in forming propellers with radially increasing pitch. In accordance with these purposes tests were carried out on 28 propellers.
Lead-Free vs Tin-Lead Reliability of Advanced Electronic Assemblies
NASA Technical Reports Server (NTRS)
Ghaffarian, Reza
2005-01-01
This presentation will provide the technical background and specific information published in literature related to reliability test, analyses, modeling, and associated issues for lead-free solder package assemblies in comparison to their tin-lead solder alloys. It also presents current understanding of lead-free thermal cycle test performance in support.
Code of Federal Regulations, 2010 CFR
2010-04-01
... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...
Code of Federal Regulations, 2014 CFR
2014-04-01
... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...
Code of Federal Regulations, 2013 CFR
2013-04-01
... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...
Code of Federal Regulations, 2012 CFR
2012-04-01
... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...
Code of Federal Regulations, 2011 CFR
2011-04-01
... POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and...
Katoh, Masahiko; Risky, Elsya; Sato, Takeshi
2017-10-23
This study conducted plant growth tests using a rhizobox system to quantitatively determine the distance of immobilization lead migrating from contaminated soil into uncontaminated rhizosphere soil, and to assess the lead phases accumulated in rhizosphere soil by sequential extraction. Without the hydroxyapatite, exchangeable lead fractions increased as the rhizosphere soil got closer to the contaminated soil. Exchangeable lead fractions were higher even in the rhizosphere soil that shares a boundary with the root surface than in the soil before being planted. Thus, plant growth of hairy vetch was lower in the soil without the hydroxyapatite than in the soil with the hydroxyapatite. The presence of hydroxyapatite may immobilize the majority of lead migrating from contaminated soil into the rhizosphere soil within 1 mm from the contaminated soil. The dominant lead fraction in the rhizosphere soil with the hydroxyapatite was residual. Thus, plant growth was not suppressed and the lead concentration of the plant shoot remained at the background level. These results indicate that the presence of hydroxyapatite in the rhizosphere soil at 5% wt may immobilize most of the lead migrating into the rhizosphere soil within 1 mm from the contaminated soil, resulting in the prevention of lead migration toward the root surface.
Risky, Elsya; Sato, Takeshi
2017-01-01
This study conducted plant growth tests using a rhizobox system to quantitatively determine the distance of immobilization lead migrating from contaminated soil into uncontaminated rhizosphere soil, and to assess the lead phases accumulated in rhizosphere soil by sequential extraction. Without the hydroxyapatite, exchangeable lead fractions increased as the rhizosphere soil got closer to the contaminated soil. Exchangeable lead fractions were higher even in the rhizosphere soil that shares a boundary with the root surface than in the soil before being planted. Thus, plant growth of hairy vetch was lower in the soil without the hydroxyapatite than in the soil with the hydroxyapatite. The presence of hydroxyapatite may immobilize the majority of lead migrating from contaminated soil into the rhizosphere soil within 1 mm from the contaminated soil. The dominant lead fraction in the rhizosphere soil with the hydroxyapatite was residual. Thus, plant growth was not suppressed and the lead concentration of the plant shoot remained at the background level. These results indicate that the presence of hydroxyapatite in the rhizosphere soil at 5% wt may immobilize most of the lead migrating into the rhizosphere soil within 1 mm from the contaminated soil, resulting in the prevention of lead migration toward the root surface. PMID:29065529
Childhood Lead Exposure from Battery Recycling in Vietnam
Van Tung, Lo; Wallace, Ryan M.; Havens, Deborah J.; Karr, Catherine J.; Bich Diep, Nguyen; Croteau, Gerry A.; Beaudet, Nancy J.; Duy Bao, Nguyen
2015-01-01
Background. Battery recycling facilities in developing countries can cause community lead exposure. Objective. To evaluate child lead exposure in a Vietnam battery recycling craft village after efforts to shift home-based recycling outside the village. Methods. This cross-sectional study evaluated 109 children in Dong Mai village, using blood lead level (BLL) measurement, parent interview, and household observation. Blood samples were analyzed with a LeadCare II field instrument; highest BLLs (≥45 μg/dL) were retested by laboratory analysis. Surface and soil lead were measured at 11 households and a school with X-ray fluorescence analyzer. Results. All children had high BLLs; 28% had BLL ≥45 μg/dL. Younger age, family recycling, and outside brick surfaces were associated with higher BLL. Surface and soil lead levels were high at all tested homes, even with no recycling history. Laboratory BLLs were lower than LeadCare BLLs, in 24 retested children. Discussion. In spite of improvements, lead exposure was still substantial and probably associated with continued home-based recycling, legacy contamination, and workplace take-home exposure pathways. There is a need for effective strategies to manage lead exposure from battery recycling in craft villages. These reported BLL values should be interpreted cautiously, although the observed field-laboratory discordance may reflect bias in laboratory results. PMID:26587532
Du, Yan-Jun; Jiang, Ning-Jun; Shen, Shui-Long; Jin, Fei
2012-07-30
Remediation of contaminated lands in China urban areas is of great concern. Degradation of construction facilities caused by acid rain is a serious environmental pollution issue in China. This paper presents an investigation of the effects of acid rain on leaching and hydraulic properties of cement-based solidified/stabilized lead contaminated soil. Laboratory tests including infiltration test and soaking test are conducted. It is found that the soil hydraulic conductivity decreases with increase in the pore volume of flow of permeant liquids (acid rain and distilled water). The decreasing rate in the case of the acid rain is lower than that in the case of the distilled water. The soaking test results show that pH and the presence of sulfate ions of acid rain have considerable influence on the leached concentrations and leaching rate of calcium. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Wood, Donald H.; Windler, Ray
1935-01-01
This report describes and gives the results of tests made to determine the effect of lateral inclination of the propeller thrust axis to the direction of flight. A wing-nacelle-propeller combination with the nacelle axis located successively parallel to and at 15 degrees to the perpendicular to the leading edge of a wing was tested with the combination at several angles of yaw. Tests of the wing alone at the same angles of yaw were also made. The data are presented in the usual graphic form. An increase in propulsive efficiency with increase in angle of the thrust axis was found. The change in net efficiency, found by charging the whole nacelle drag to the power unit, was negligible, however, within the range of the tests.
Streamlines behind curved shock waves in axisymmetric flow fields
NASA Astrophysics Data System (ADS)
Filippi, A. A.; Skews, B. W.
2018-07-01
Streamlines behind axisymmetric curved shock waves were used to predict the internal surfaces that produced them. Axisymmetric ring wedge models with varying internal radii of curvature and leading-edge angles were used to produce numerical results. Said numerical simulations were validated using experimental shadowgraph results for a series of ring wedge test pieces. The streamlines behind curved shock waves for lower leading-edge angles are examined at Mach 3.4, whereas the highest leading-edge angle cases are explored at Mach 2.8 and 3.4. Numerical and theoretical streamlines are compared for the highest leading-edge angle cases at Mach 3.6. It was found that wall-bounding theoretical streamlines did not match the internal curved surface. This was due to extreme streamline curvature curving the streamlines when the shock angle approached the Mach angle at lower leading-edge angles. Increased Mach number and internal radius of curvature produced more reasonable results. Very good agreement was found between the theoretical and numerical streamlines at lower curvatures before the influence of the trailing edge expansion fan.
NASA Technical Reports Server (NTRS)
Dankanich, John W.; Swiatek, Michael W.; Yim, John T.
2012-01-01
The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.
NASA Astrophysics Data System (ADS)
Chen, Wei-fang; Pan, Ling; Chen, Li-fang; Yu, Zhe; Wang, Qiong; Yan, Chang-cheng
2014-08-01
Ethylene diamine tetraacetic acid (EDTA) and sodium dodecyl sulfate (SDS) were employed to impregnate activated carbons for the purpose of lead removal. The mechanisms of surface impregnation and lead adsorption method of chemical regeneration were investigated. Results showed that the highest impregnation of EDTA and SDS on activated carbon was 0.33 and 0.96 mmol/g, respectively. Adsorption capacities for lead of EDTA and SDS impregnated activated carbons reached 0.29 and 0.24 mmol/g. Rapid small scale column tests of adsorption and regeneration were conducted. Lead adsorption was greatly enhanced by EDTA impregnation. In addition, EDTA impregnated adsorbent was able to be successful regenerated by HNO3 and thus reused.
SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, S; Vanderhoek, M
Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beammore » entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.« less
NASA Technical Reports Server (NTRS)
Hall, Steven R.; Walker, Bruce K.
1990-01-01
A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.
Systematic evaluation of dissolved lead sorption losses to particulate syringe filter materials.
Minning, Thomas; Lytle, Darren A; Pham, Maily; Kelty, Keith
2015-06-01
Distinguishing between soluble and particulate lead in drinking water is useful in understanding the mechanism of lead release and identifying remedial action. Typically, particulate lead is defined as the amount of lead removed by a 0.45-μm filter. Unfortunately, there is little guidance regarding selection of filter membrane material and little consideration to the possibility of the sorption of dissolved lead to the filter. The objective of this work was to examine the tendency of 0.45-μm syringe filter materials to adsorb lead. Tests were performed with water containing 40 and 24 μg/L soluble lead at pH 7 buffered with 50 mg C/L dissolved inorganic concentration (DIC). The amounts of lead sorbed greatly varied by filter, and only two filter types, polypropylene and mixed cellulose esters, performed well and are recommended. Great care must be taken in choosing a filter when filtering soluble lead and interpreting filter results.
Kosky, Christopher A; Bonakis, Anastasios; Yogendran, Arthee; Hettiarachchi, Gihan; Dargan, Paul I; Williams, Adrian J
2016-11-15
Drugs and psychoactive substances can cause sleepiness and when undetected, may lead to over diagnosis of central hypersomnias. We performed urine drug testing using gas chromatography-mass spectrometry in adults undergoing multiple sleep latency testing (MSLT) for a suspected central hypersomnia. We examined how the drug test results modified the treating physician's diagnosis. One hundred eighty-six consecutive patients with a suspected central hypersomnia who underwent clinical assessment, MSLT and urine drug testing by gas chromatography-mass spectrometry were retrospectively studied. Physicians made a diagnosis after clinical assessment and MSLT and were initially blinded to the urine drug test results. A third of patients assessed for subjective hypersomnia had a positive urine drug test for a substance affecting sleep. Opioids, cannabis, and amphetamines were the commonest drugs detected. Using MSLT, 35 (18.8%) of 186 patients had objective hypersomnia that may have been due to a drug or substance. Drugs or substances may have confounded the MSLT in 11 (20.1%) of 53 patients who fulfilled diagnostic criteria for idiopathic hypersomnia, and 12 (52%) of 23 of those who fulfilled diagnostic criteria for narcolepsy without cataplexy. Of the 75 positive urine drug samples, 61 (81%) were substances or medications not revealed in the physician interview. The treating physician had not suspected drugs or substances as a possible cause of objective hypersomnia in 34 (97%) of the 35 patients. Drugs and psychoactive substances can confound the results of the MSLT and when undetected could lead to over diagnosis of central hypersomnias. © 2016 American Academy of Sleep Medicine
Mohanty, Sujit K; Yu, Chi Li; Gopishetty, Sridhar; Subramanian, Mani
2014-08-06
Excess consumption of caffeine (>400 mg/day/adult) can lead to adverse health effects. Recent introduction of caffeinated products (gums, jelly beans, energy drinks) might lead to excessive consumption, especially among children and nursing mothers, hence attracting the Food and Drug Administration's attention and product withdrawals. An "in-home" test will aid vigilant consumers in detecting caffeine in beverages and milk easily and quickly, thereby restricting its consumption. Known diagnostic methods lack speed and sensitivity. We report a caffeine dehydrogenase (Cdh)-based test which is highly sensitive (1-5 ppm) and detects caffeine in beverages and mother's milk in 1 min. Other components in these complex test samples do not interfere with the detection. Caffeine-dependent reduction of the dye iodonitrotetrazolium chloride results in shades of pink proportional to the levels in test samples. This test also estimates caffeine levels in pharmaceuticals, comparable to high-performance liquid chromatography. The Cdh-based test is the first with the desired attributes of a rapid and robust caffeine diagnostic kit.
Yang, Zixuan; Kan, Bo; Li, Jinxu; Qiao, Lijie; Volinsky, Alex A; Su, Yanjing
2017-11-14
Hydrostatic pressure effects on pitting initiation and propagation in X70 steel are investigated by evaluating metastable pitting probability using electrochemical methods and immersion corrosion tests in containing chlorine ion solution. Potentiodynamic tests indicated that hydrostatic pressure can decrease the breakdown potential and lead to a reduced transpassivity region. Metastable test results revealed that hydrostatic pressure can increase metastable pitting formation frequency and promote stabilization of metastable pitting growth. Electrochemical impedance spectroscopy (EIS) results indicate that Hydrostatic pressure decreases the charge transfer resistance and increases the dissolution rate within the cavities. Corrosion test results also indicated that pitting initiation and propagation are accelerated by hydrostatic pressure. Result validity was verified by evaluating metastable pitting to predict pitting corrosion resistance.
Yang, Zixuan; Kan, Bo; Li, Jinxu; Su, Yanjing; Qiao, Lijie; Volinsky, Alex A.
2017-01-01
Hydrostatic pressure effects on pitting initiation and propagation in X70 steel are investigated by evaluating metastable pitting probability using electrochemical methods and immersion corrosion tests in containing chlorine ion solution. Potentiodynamic tests indicated that hydrostatic pressure can decrease the breakdown potential and lead to a reduced transpassivity region. Metastable test results revealed that hydrostatic pressure can increase metastable pitting formation frequency and promote stabilization of metastable pitting growth. Electrochemical impedance spectroscopy (EIS) results indicate that Hydrostatic pressure decreases the charge transfer resistance and increases the dissolution rate within the cavities. Corrosion test results also indicated that pitting initiation and propagation are accelerated by hydrostatic pressure. Result validity was verified by evaluating metastable pitting to predict pitting corrosion resistance. PMID:29135912
Envisioning a Career with Purpose: Calling and Its Spiritual Underpinnings among College Students
ERIC Educational Resources Information Center
Gregory, David
2013-01-01
The current study tested the hypothesis that student spirituality would relate positively to the construct of calling and that these constructs together would lead toward career decidedness. To test this model, a sample consisting of 1139 students from a large Midwest university was surveyed. Results supported these hypotheses only in part. The…
ERIC Educational Resources Information Center
Porter, Kristin E.
2016-01-01
In education research and in many other fields, researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple…
Factors that lead to failure with wood adhesive bonds
Charles R. Frihart; James F. Beecher
2016-01-01
Understanding what makes a good wood adhesive is difficult since the type of adhesive, wood species, bonding process, and resultant products vary considerably. Wood bonds are subjected to a variety of tests that reflect the different product performance criteria in diverse countries. The most common tests involve some type of moisture resistance; both wood and adhesive...
Sales, A; Alvarez, A; Areal, M Rodriguez; Maldonado, L; Marchisio, P; Rodríguez, M; Bedascarrasbure, E
2006-10-11
Argentinean propolis is exported to different countries, specially Japan. The market demands propolis quality control according to international standards. The analytical determination of some metals, as lead in food, is very important for their high toxicity even in low concentrations and because of their harmful effects on health. Flavonoids, the main bioactive compounds of propolis, tend to chelate metals as lead, which becomes one of the main polluting agents of propolis. The lead found in propolis may come from the atmosphere or it may be incorporated in the harvest, extraction and processing methods. The aim of this work is to evaluate lead level on Argentinean propolis determined by electrothermal atomic absorption spectrometry (ET AAS) and UV-vis spectrophotometry (UV-visS) methods, as well as the effect of harvest methods on those contents. A randomized test with three different treatments of collection was made to evaluate the effect of harvest methods. These procedures were: separating wedges (traditional), netting plastic meshes and stamping out plastic meshes. By means of the analysis of variance technique for multiple comparisons (ANOVA) it was possible to conclude that there are significant differences between scraped and mesh methods (stamped out and mosquito netting meshes). The results obtained in the present test would allow us to conclude that mesh methods are more advisable than scraped ones in order to obtain innocuous and safe propolis with minor lead contents. A statistical comparison of lead determination by both, ET AAS and UV-visS methods, demonstrated that there is not a significant difference in the results achieved with the two analytical techniques employed.
[Analysis of heavy metals monitoring results in food in Shaoxing in 2014].
Fan, Wei; Wang, Jing; Wu, Hongmiao; Lian, Lingjun; Du, Sai; Chen, Li
2015-11-01
To investigate heavy metals contamination level in food in Shaoxing, and to provide basis evidence for supervising heavy metals pollution in food and environmental pollution control in Shaoxing. Food samples in 2014 were detected for lead, cadmium, mercury, arsenic, nickel, copper and chromium by national standard methods, and the results were evaluated by GB 2762-2012 Pollutants limits in food. 1384 samples from 10 food categories were collected and tested for lead, cadmium, mercury and arsenic, the over standard rates were 2.0%, 3.0%, 1.5% and 0.22%, respectively, the median were 0.019, 0.0085, 0.0024 and 0.015 mg/kg, respectively; 273 samples were collected and tested for nickel, the detection rate was 48.4%, the median was 0.010 mg/kg; 255 samples were collected and tested for chromium, the detection rate was 14.9%, the median was 0.0050 mg/kg; 486 samples were collected and tested for copper, the detection rate was 94.0%, the median was 1.34 mg/kg. The heavy metals over standard rate of aquatic products, animal internal organs and grain were relatively high, 16.9%, 7.9% and 7.3% cadmium in swimming crabs exceeded standard seriously, the over standard rate was 38.9%. The overall pollution of heavy metals in food are not high in Shaoxing in 2014, but some food (aquatic products, animal internal organs and grain) pollution are relatively outstanding, and have the over standard problems of lead, cadmium, mercury and arsenic.
Confirmatory analysis of field-presumptive GSR test sample using SEM/EDS
NASA Astrophysics Data System (ADS)
Toal, Sarah J.; Niemeyer, Wayne D.; Conte, Sean; Montgomery, Daniel D.; Erikson, Gregory S.
2014-09-01
RedXDefense has developed an automated red-light/green-light field presumptive lead test using a sampling pad which can be subsequently processed in a Scanning Electron Microscope for GSR confirmation. The XCAT's sampling card is used to acquire a sample from a suspect's hands on the scene and give investigators an immediate presumptive as to the presence of lead possibly from primer residue. Positive results can be obtained after firing as little as one shot. The same sampling card can then be sent to a crime lab and processed on the SEM for GSR following ASTM E-1588-10 Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry, in the same manner as the existing tape lifts currently used in the field. Detection of GSR-characteristic particles (fused lead, barium, and antimony) as small as 0.8 microns (0.5 micron resolution) has been achieved using a JEOL JSM-6480LV SEM equipped with an Oxford Instruments INCA EDS system with a 50mm2 SDD detector, 350X magnification, in low-vacuum mode and in high vacuum mode after coating with carbon in a sputter coater. GSR particles remain stable on the sampling pad for a minimum of two months after chemical exposure (long term stability tests are in progress). The presumptive result provided by the XCAT yields immediate actionable intelligence to law enforcement to facilitate their investigation, without compromising the confirmatory test necessary to further support the investigation and legal case.
Physically based DC lifetime model for lead zirconate titanate films
NASA Astrophysics Data System (ADS)
Garten, Lauren M.; Hagiwara, Manabu; Ko, Song Won; Trolier-McKinstry, Susan
2017-09-01
Accurate lifetime predictions for Pb(Zr0.52Ti0.48)O3 thin films are critical for a number of applications, but current reliability models are not consistent with the resistance degradation mechanisms in lead zirconate titanate. In this work, the reliability and lifetime of chemical solution deposited (CSD) and sputtered Pb(Zr0.52Ti0.48)O3 thin films are characterized using highly accelerated lifetime testing (HALT) and leakage current-voltage (I-V) measurements. Temperature dependent HALT results and impedance spectroscopy show activation energies of approximately 1.2 eV for the CSD films and 0.6 eV for the sputtered films. The voltage dependent HALT results are consistent with previous reports, but do not clearly indicate what causes device failure. To understand more about the underlying physical mechanisms leading to degradation, the I-V data are fit to known conduction mechanisms, with Schottky emission having the best-fit and realistic extracted material parameters. Using the Schottky emission equation as a base, a unique model is developed to predict the lifetime under highly accelerated testing conditions based on the physical mechanisms of degradation.
Improvement of maneuver aerodynamics by spanwise blowing
NASA Technical Reports Server (NTRS)
Erickson, G. E.; Campbell, J. F.
1977-01-01
Spanwise blowing was used to test a generalized wind-tunnel model to investigate component concepts in order to provide improved maneuver characteristics for advanced fighter aircraft. Primary emphasis was placed on performance, stability, and control at high angles of attack and subsonic speeds. Test data were obtained in the Langley high speed 7 by 10 foot tunnel at free stream Mach numbers up to 0.50 for a range of model angles of attack, jet momentum coefficients, and leading and trailing edge flap deflection angles. Spanwise blowing on a 44 deg swept trapezoidal wing resulted in leading edge vortex enhancement with subsequent large vortex induced lift increments and drag polar improvements at the higher angles of attack. Small deflections of a leading edge flap delayed these lift and drag benefits to higher angles of attack. In addition, blowing was more effective at higher Mach numbers. Spanwise blowing in conjunction with a deflected trailing edge flap resulted in lift and drag benefits that exceeded the summation of the effects of each high lift device acting alone. Asymmetric blowing was an effective lateral control device at the higher angles of attack.
Microprocessor-based cardiotachometer
NASA Technical Reports Server (NTRS)
Crosier, W. G.; Donaldson, J. A.
1981-01-01
Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.
Johansson, Johannes; Wårdell, Karin; Hemm, Simone
2018-01-01
The success of deep brain stimulation (DBS) relies primarily on the localization of the implanted electrode. Its final position can be chosen based on the results of intraoperative microelectrode recording (MER) and stimulation tests. The optimal position often differs from the final one selected for chronic stimulation with the DBS electrode. The aim of the study was to investigate, using finite element method (FEM) modeling and simulations, whether lead design, electrical setup, and operating modes induce differences in electric field (EF) distribution and in consequence, the clinical outcome. Finite element models of a MER system and a chronic DBS lead were developed. Simulations of the EF were performed for homogenous and patient-specific brain models to evaluate the influence of grounding (guide tube vs. stimulator case), parallel MER leads, and non-active DBS contacts. Results showed that the EF is deformed depending on the distance between the guide tube and stimulating contact. Several parallel MER leads and the presence of the non-active DBS contacts influence the EF distribution. The DBS EF volume can cover the intraoperatively produced EF, but can also extend to other anatomical areas. In conclusion, EF deformations between stimulation tests and DBS should be taken into consideration as they can alter the clinical outcome. PMID:29415442
Academic self-concept of ability and cortisol reactivity.
Minkley, N; Westerholt, D M; Kirchner, W H
2014-05-01
The present study aimed to clarify the relationship between a school-specific trait (academic self-concept of ability [ASCA]) and hormonal stress response by using a trait-compatible stressor (test). First, we determined 52 students' ASCA scores for biology and measured their salivary cortisol concentration before and after a biology test (experimental group, n=28) or a free writing task (control group, n=24). For participants who took the test, statistical analysis indicated a significant negative correlation between ASCA score and cortisol response. In contrast, the control group showed a decrease in cortisol concentrations between test times and no correlation between cortisol concentration and ASCA scores were found. These findings indicated an interaction between ASCA scores and hormonal stress response when an academic-related stressor is present. Furthermore, these variables might influence each other adversely: high cortisol concentrations during a test situation may lead to greater feelings of insecurity, resulting in low ASCA scores and awareness of these low scores may lead to a further increase in cortisol, creating a vicious cycle.
A novel free floating accelerometer force balance system for shock tunnel applications
NASA Astrophysics Data System (ADS)
Joarder, R.; Mahaptra, D. R.; Jagadeesh, G.
In order to overcome the interference of the model mounting system with the external aerodynamics of the body during shock tunnel testing, a new free floating internally mountable balance system that ensures unrestrained model motion during testing has been designed, fabricated and tested. Minimal friction ball bearings are used for ensuring the free floating condition of the model during tunnel testing. The drag force acting on a blunt leading edge flat plate at hypersonic Mach number has been measured using the new balance system. Finite element model (FEM) and CFD are exhaustively used in the design as well as for calibrating the new balance system. The experimentally measured drag force on the blunt leading edge flat plate at stagnation enthalpy of 0.7 and 1.2 MJ/kg and nominal Mach number of 5.75 matches well with FEM results. The concept can also be extended for measuring all the three fundamental aerodynamic forces in short duration test facilities like free piston driven shock tunnels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nash, C.; Williams, M.; Restivo, M.
All prior testing with SuperLig® 639 has been done with the aqueous concentration of LAW at ~5 M [Na+], where the resin sinks, and can be used in a conventional down-flow column orientation. However, the aqueous LAW stream from the Waste Treatment Plant is expected to be ~8 M [Na+]. The resin would float in this higher density liquid, potentially disrupting the ability to achieve a good decontamination due to poor packing of the resin that leads to channeling. Testing was completed with a higher salt concentration in the feed simulant (7.8 M [Na+]) in an engineering-scale apparatus with twomore » columns, each containing ~0.9 L of resin. Testing of this system used a simulant of the LAW solution, and substituted ReO4 - as a surrogate for TcO4 -. Results were then compared using computer modeling. Bench-scale testing was also performed, and examined an unconstrained resin bed, while engineering-scale tests used both constrained and unconstrained beds in a two-column, lead and lag sequential arrangement.« less
Aerodynamic Characterization of a Thin, High-Performance Airfoil for Use in Ground Fluids Testing
NASA Technical Reports Server (NTRS)
Broeren, Andy P.; Lee, Sam; Clark, Catherine
2013-01-01
The FAA has worked with Transport Canada and others to develop allowance times for aircraft operating in ice-pellet precipitation. Wind-tunnel testing has been carried out to better understand the flowoff characteristics and resulting aerodynamic effects of anti-icing fluids contaminated with ice pellets using a thin, high-performance wing section at the National Research Council of Canada Propulsion and Icing Wind Tunnel. The objective of this paper is to characterize the aerodynamic behavior of this wing section in order to better understand the adverse aerodynamic effects of anti-icing fluids and ice-pellet contamination. Aerodynamic performance data, boundary-layer surveys and flow visualization were conducted at a Reynolds number of approximately 6.0 x 10(exp 6) and a Mach number of 0.12. The clean, baseline model exhibited leading-edge stall characteristics including a leading-edge laminar separation bubble and minimal or no separation on the trailing edge of the main element or flap. These results were consistent with expected 2-D aerodynamics and showed no anomalies that could adversely affect the evaluation of anti-icing fluids and ice-pellet contamination on the wing. Tests conducted with roughness and leading-edge flow disturbances helped to explain the aerodynamic impact of the anti-icing fluids and contamination. The stalling characteristics of the wing section with fluid and contamination appear to be driven at least partially by the effects of a secondary wave of fluid that forms near the leading edge as the wing is rotated in the simulated takeoff profile. These results have provided a much more complete understanding of the adverse aerodynamic effects of anti-icing fluids and ice-pellet contamination on this wing section. This is important since these results are used, in part, to develop the ice-pellet allowance times that are applicable to many different airplanes.
Aerodynamic Characterization of a Thin, High-Performance Airfoil for Use in Ground Fluids Testing
NASA Technical Reports Server (NTRS)
Broeren, Andy P.; Lee, Sam; Clark, Catherine
2013-01-01
The FAA has worked with Transport Canada and others to develop allowance times for aircraft operating in ice-pellet precipitation. Wind-tunnel testing has been carried out to better understand the flowoff characteristics and resulting aerodynamic effects of anti-icing fluids contaminated with ice pellets using a thin, high-performance wing section at the National Research Council of Canada Propulsion and Icing Wind Tunnel. The objective of this paper is to characterize the aerodynamic behavior of this wing section in order to better understand the adverse aerodynamic effects of anti-icing fluids and ice-pellet contamination. Aerodynamic performance data, boundary-layer surveys and flow visualization were conducted at a Reynolds number of approximately 6.0×10(exp 6) and a Mach number of 0.12. The clean, baseline model exhibited leading-edge stall characteristics including a leading-edge laminar separation bubble and minimal or no separation on the trailing edge of the main element or flap. These results were consistent with expected 2-D aerodynamics and showed no anomalies that could adversely affect the evaluation of anti-icing fluids and ice-pellet contamination on the wing. Tests conducted with roughness and leading-edge flow disturbances helped to explain the aerodynamic impact of the anti-icing fluids and contamination. The stalling characteristics of the wing section with fluid and contamination appear to be driven at least partially by the effects of a secondary wave of fluid that forms near the leading edge as the wing is rotated in the simulated takeoff profile. These results have provided a much more complete understanding of the adverse aerodynamic effects of anti-icing fluids and ice-pellet contamination on this wing section. This is important since these results are used, in part, to develop the ice-pellet allowance times that are applicable to many different airplanes.
A Pilot Study of Children's Blood Lead Levels in Mount Isa, Queensland.
Green, Donna; Sullivan, Marianne; Cooper, Nathan; Dean, Annika; Marquez, Cielo
2017-12-13
Mount Isa, Queensland, is one of three Australian cities with significant lead emissions due to nonferrous mining and smelting. Unlike the two other cities with lead mines or smelters, Mount Isa currently has no system of annual, systematic, community-wide blood lead level testing; and testing rates among Indigenous children are low. In previous screenings, this group of children has been shown to have higher average blood lead levels than non-Indigenous children. The first aim of this study was to assess whether parents and children would participate in less invasive, rapid point-of-care capillary testing. The second aim was to measure blood lead levels among a range of children that roughly reflected the percentage of the Indigenous/non-Indigenous population. This pilot study is based on a convenience sample of children between the ages of 12 and 83 months who were recruited to participate by staff at a Children and Family Centre. Over three half-days, 30 children were tested using capillary blood samples and the LeadCare II Point-of-Care testing system. Rapid point-of-care capillary testing was well tolerated by the children. Of 30 children tested, 40% ( n = 12) had blood lead levels ≥5 µg/dL and 10% had levels ≥10 µg/dL. The highest blood lead level measured was 17.3 µg/dL. The percentage of children with blood lead levels ≥5 µg/dL was higher among Indigenous children compared to non-Indigenous (64.2% compared to 18.8%) as was the geometric mean level (6.5 (95% CI, 4.7, 9.2) versus 2.4 (95% CI, 1.8, 3.1)), a statistically significant difference. Though based on a small convenience sample, this study identified 12 children (40%) of the sample with blood lead levels ≥5 µg/dL. Due to historical and ongoing heavy metal emissions from mining and smelting in Mount Isa, we recommend a multi-component program of universal blood lead level testing, culturally appropriate follow-up and intervention for children who are identified with blood lead levels ≥5 µg/dL. We further recommend focused outreach and assistance to the Indigenous community, and further control of emissions and remediation of existing environmental lead contamination in children's play and residential areas.
Primary prevention of pediatric lead exposure requires new approaches to transfusion screening.
Gehrie, Eric; Keiser, Amaris; Dawling, Sheila; Travis, James; Strathmann, Frederick G; Booth, Garrett S
2013-09-01
To facilitate further assessment of transfusion-associated lead exposure by designing a procedure to test packed red blood cells (pRBCs) prepared for transfusion. The relationship between pRBCs and whole blood lead concentration was investigated in 27 samples using a modified clinical assay. Lead concentrations were measured in 100 pRBC units. Our sample preparation method demonstrated a correlation between whole blood lead and pRBC lead concentrations (R(2) = 0.82). In addition, all 100 pRBC units tested had detectable lead levels. The median pRBC lead concentration was 0.8 μg/dL, with an SD of 0.8 μg/dL and a range of 0.2-4.1 μg/dL. In addition, after only a few days of storage, approximately 25% of whole blood lead was found in the supernatant plasma. Transfusion of pRBCs is a source of lead exposure. Here we report the quantification of lead concentration in pRBCs. We found a >20-fold range of lead concentrations in the samples tested. Pretransfusion testing of pRBC units according to our proposed approach or donor screening of whole blood lead and selection of below-average units for transfusion to children would diminish an easily overlooked source of pediatric lead exposure. Copyright © 2013 Mosby, Inc. All rights reserved.
Lead Paint Exposure Assessment in High Bays of Johnson Space Center
NASA Technical Reports Server (NTRS)
Stanch, Penney; Plaza, Angel; Keprta, Sean
2008-01-01
This slide presentation reviews the program to assess the possibility of lead paint exposure in the high bays of some of the Johnson Space Center buildings. Some of the buildings in the Manned Space Flight Center (MSC) were built in 1962 and predate any considerations to reduce lead in paints and coatings. There are many of these older buildings that contain open shops and work areas that have open ceilings, These shops include those that had operations that use leaded gasoline, batteries, and lead based paints. Test were planned to be conducted in three phases: (1) Surface Dust sampling, (2) personal exposure montioring, and (3) Ceiling paint Sampling. The results of the first two phases were reviewed. After considering the results of the first two phases, and the problems associated with the retrieval of samples from high ceilings, it was determined that the evaluation of ceiling coatings would be done on a project by project and in response to a complaint.
Hypervelocity Impact (HVI). Volume 1; General Introduction
NASA Technical Reports Server (NTRS)
Gorman, Michael R.; Ziola, Steven M.
2007-01-01
During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. This volume contains an executive summary, overview of the method, brief descriptions of all targets, and highlights of results and conclusions.
Altaras, Robin; Nuwa, Anthony; Agaba, Bosco; Streat, Elizabeth; Tibenderana, James K.; Martin, Sandrine; Strachan, Clare E.
2016-01-01
Background Successful scale-up in the use of malaria rapid diagnostic tests (RDTs) requires that patients accept testing and treatment based on RDT results and that healthcare providers treat according to test results. Patient-provider communication is a key component of quality care, and leads to improved patient satisfaction, higher adherence to treatment and better health outcomes. Voiced or perceived patient expectations are also known to influence treatment decision-making among healthcare providers. While there has been a growth in literature on provider practices around rapid testing for malaria, there has been little analysis of inter-personal communication around the testing process. We investigated how healthcare providers and patients interact and engage throughout the diagnostic and treatment process, and how the testing service is experienced by patients in practice. Methods This research was conducted alongside a larger study which explored determinants of provider treatment decision-making following negative RDT results in a rural district (Kibaale) in mid-western Uganda, ten months after RDT introduction. Fifty-five patients presenting with fever were observed during routine outpatient visits at 12 low-level public health facilities. Observation captured communication practices relating to test purpose, results, diagnosis and treatment. All observed patients or caregivers were immediately followed up with in-depth interview. Analysis followed the ‘framework’ approach. A summative approach was also used to analyse observation data. Results Providers failed to consistently communicate the reasons for carrying out the test, and particularly to RDT-negative patients, a diagnostic outcome or the meaning of test results, also leading to confusion over what the test can detect. Patients appeared to value testing, but were frustrated by the lack of communication on outcomes. RDT-negative patients were dissatisfied by the absence of information on an alternative diagnosis and expressed uncertainty around adequacy of proposed treatment. Conclusions Poor provider communication practices around the testing process, as well as limited inter-personal exchange between providers and patients, impacted on patients’ perceptions of their proposed treatment. Patients have a right to health information and may be more likely to accept and adhere to treatment when they understand their diagnosis and treatment rationale in relation to their perceived health needs and visit expectations. PMID:27494507
DOE Office of Scientific and Technical Information (OSTI.GOV)
Acikel, Volkan, E-mail: vacik@ee.bilkent.edu.tr; Atalar, Ergin; Uslubas, Ali
Purpose: The authors’ purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (MRI) examination. Methods: In this study, IPG case and electrode are modeled with a voltage source and impedance. Values of these parameters are found using the modified transmission line method (MoTLiM) and the method of moments (MoM) simulations. Once the parameter values of an electrode/IPG case model are determined, they can be connected tomore » any lead, and tip heating can be analyzed. To validate these models, both MoM simulations and MR experiments were used. The induced currents on the leads with the IPG case or electrode connections were solved using the proposed models and the MoTLiM. These results were compared with the MoM simulations. In addition, an electrode was connected to a lead via an inductor. The dissipated power on the electrode was calculated using the MoTLiM by changing the inductance and the results were compared with the specific absorption rate results that were obtained using MoM. Then, MRI experiments were conducted to test the IPG case and the electrode models. To test the IPG case, a bare lead was connected to the case and placed inside a uniform phantom. During a MRI scan, the temperature rise at the lead was measured by changing the lead length. The power at the lead tip for the same scenario was also calculated using the IPG case model and MoTLiM. Then, an electrode was connected to a lead via an inductor and placed inside a uniform phantom. During a MRI scan, the temperature rise at the electrode was measured by changing the inductance and compared with the dissipated power on the electrode resistance. Results: The induced currents on leads with the IPG case or electrode connection were solved for using the combination of the MoTLiM and the proposed lumped circuit models. These results were compared with those from the MoM simulations. The mean square error was less than 9%. During the MRI experiments, when the IPG case was introduced, the resonance lengths were calculated to have an error less than 13%. Also the change in tip temperature rise at resonance lengths was predicted with less than 4% error. For the electrode experiments, the value of the matching impedance was predicted with an error less than 1%. Conclusions: Electrical models for the IPG case and electrode are suggested, and the method is proposed to determine the parameter values. The concept of matching of the electrode to the lead is clarified using the defined electrode impedance and the lead Thevenin impedance. The effect of the IPG case and electrode on tip heating can be predicted using the proposed theory. With these models, understanding the tissue heating due to the implants becomes easier. Also, these models are beneficial for implant safety testers and designers. Using these models, worst case conditions can be determined and the corresponding implant test experiments can be planned.« less
The purpose of this issue paper is to address the availability and performance characteristics of portable lead test kits especially suited for lead in paint, procedures for evaluating the performance of these test kits, and the availability of performance evaluation (PE) materia...
EFFECTS OF TREATMENTS ON SOIL-LEAD BIOAVAILABILITY: IMPLICATIONS OF IN-VITRO EXTRACTION TESTING
A field-scale study on the use of phosphate amendments to reduce lead bioavailabity from soil is being conducted at the Joplin site. One of the tools used to evaluate whether lead bioavailability is being reduced is an in vitro extraction test. The in vitro test simulates the gas...
Heat-Pipe-Cooled Leading Edges for Hypersonic Vehicles
NASA Technical Reports Server (NTRS)
Glass, David E.
2006-01-01
Heat pipes can be used to effectively cool wing leading edges of hypersonic vehicles. . Heat-pipe leading edge development. Design validation heat pipe testing confirmed design. Three heat pipes embedded and tested in C/C. Single J-tube heat pipe fabricated and testing initiated. HPCLE work is currently underway at several locations.
Boverhof, Darrell R; Wiescinski, Connie M; Botham, Phil; Lees, David; Debruyne, Eric; Repetto-Larsay, Marina; Ladics, Gregory; Hoban, Denise; Gamer, Armin; Remmele, Marina; Wang-Fan, Weizheng; Ullmann, Ludwig G; Mehta, Jyotigna; Billington, Richard; Woolhiser, Michael R
2008-09-01
The mouse local lymph node assay (LLNA) has become the preferred test for evaluating the dermal sensitization potential of chemicals and requirements are now emerging for its use in the evaluation of their formulated products, especially in the European Union. However, despite its widespread use and extensive validation, the use of this assay for directly testing mixtures and formulated products has been questioned, which could lead to repeat testing using multiple animal models. As pesticide formulations are typically a specific complex blend of chemicals for use as aqueous-based dilutions, traditional vehicles prescribed for the LLNA may change the properties of these formulations leading to inaccurate test results and hazard identification. The objective of this study was to evaluate the effectiveness of an aqueous solution of Pluronic L92 block copolymer surfactant (L92) as a vehicle in the mouse LLNA across five laboratories. Three chemicals with known sensitization potential and four pesticide formulations for which the sensitization potential in guinea pigs and/or humans had previously been assessed were used. Identical LLNA protocols and test materials were used in the evaluation. Assessment of the positive control chemicals, hexylcinnamaldehyde, formaldehyde, and potassium dichromate revealed positive results when using 1% aqueous L92 as the vehicle. Furthermore, results for these chemicals were reproducible among the five laboratories and demonstrated consistent relative potency determinations. The four pesticide formulations diluted in 1% aqueous L92 also demonstrated reproducible results in the LLNA among the five laboratories. Results for these test materials were also consistent with those generated previously using guinea pigs or from human experience. These data support testing aqueous compatible chemicals or pesticide formulations using the mouse LLNA, and provide additional support for the use of 1% aqueous L92 as a suitable, aqueous-based vehicle.
Leighton, Jessica; Klitzman, Susan; Sedlar, Slavenka; Matte, Thomas; Cohen, Neal L
2003-07-01
Despite the widespread use of lead paint hazard control for children with lead poisoning, few controlled studies that estimate the effect of such control on children's blood lead levels have been published. This retrospective follow-up study examined the effects of lead hazard remediation and its timing on the blood lead levels of lead-poisoned children. From the New York City child blood lead registry, 221 children were selected who had an initial blood lead level of 20-44 micro g/dL between 1 July 1994 and 31 December 1996; were 6 months to 6 years of age; had a report of a follow-up blood lead test between 10 and 14 months after the initial test; had a lead-based paint hazard identified in the primary dwelling unit prior to the 10- to 14-month follow-up blood lead test; had resided or spent time at only one address with an identified lead-based paint hazard; and were not chelated. The decline in geometric mean blood lead levels from baseline to 10-14 months later was compared for children whose homes were remediated and whose homes were not remediated during the follow-up period. Regardless of remediation, geometric mean blood lead levels declined significantly from 24.3 micro g/dL at the initial diagnosis to 12.3 micro g/dL at the 10- to 14-month follow-up blood lead test (P<0.01). Among the 146 children whose homes were remediated the geometric mean blood lead levels declined 53% compared to 41% among the 75 children whose homes were not remediated by the follow-up blood lead test, a remediation effect of approximately 20% (P<0.01). After adjusting for potential confounders, the remediation effect was 11%, although it was no longer significant. Race was the only factor that appeared to confound the relationship: Black children had higher follow-up blood lead levels even after controlling for other factors, including the natural logarithm of the initial blood lead level. The effect of remediation appeared to be stronger for younger (10 to <36 months old) than for older (36 to 72 months old) children (P=0.06). While children in homes with earlier remediation (within less than 3 months) appeared to have greater declines in blood lead levels at the follow-up test than children in homes with later remediation (after 3 or more months), this trend was not significant when controlling for confounding factors. The findings of this study suggest that early identification of lead-poisoned children and timely investigation and abatement of hazards contribute to reducing blood lead levels. However, the apparent effect is modest and further research is needed to systematically test and improve the effectiveness of lead hazard controls.
NASA Technical Reports Server (NTRS)
Coe, P. L., Jr.; Huffman, J. K.
1979-01-01
An investigation conducted in the Langley 7 by 10 foot tunnel to determine the influence of an optimized leading-edge deflection on the low speed aerodynamic performance of a configuration with a low aspect ratio, highly swept wing. The sensitivity of the lateral stability derivative to geometric anhedral was also studied. The optimized leading edge deflection was developed by aligning the leading edge with the incoming flow along the entire span. Owing to spanwise variation of unwash, the resulting optimized leading edge was a smooth, continuously warped surface for which the deflection varied from 16 deg at the side of body to 50 deg at the wing tip. For the particular configuration studied, levels of leading-edge suction on the order of 90 percent were achieved. The results of tests conducted to determine the sensitivity of the lateral stability derivative to geometric anhedral indicate values which are in reasonable agreement with estimates provided by simple vortex-lattice theories.
NASA Astrophysics Data System (ADS)
Li, Weifeng; Zhan, Jing; Fan, Yanqing; Wei, Chang; Zhang, Chuanfu; Hwang, Jiann-Yang
2017-04-01
A pyrometallurgical process for the direct reduction of molten high-lead smelting slag obtained by the Shuikoushan (SKS) method was reported in this article using solid anthracite as the fuel and reductant. The chemical composition, the lead phase composition, and the physical properties of the molten high-lead slag were examined. The effects of the process parameters on the recovery rate of valued metals were investigated in the laboratory. According to the experimental results, a new efficient bottom blow reduction furnace was employed in the pilot-scale test for high-lead slag reduction. The results showed the average recovery rate of lead was more than 96.0% with lower Pb and high Zn content of the reducing slag under the condition of reduction temperature 1100-1200°C, coal ratio 5.5-7.5%, reduction time 90-150 min, CaO/SiO2 ratio 0.35-0.45, and FeO/SiO2 ratio 1.4-1.55. Moreover, nearly 250 kg of standard coal per ton of crude Pb output was reduced compared with the blast furnace reduction process.
Adult Blood Lead Levels in Minnesota: Rates and Trends, 2005-2012.
Landsteiner, Adrienne; Yendell, Stephanie; Lindgren, Paula; Olson, Larry; Williams, Allan
2016-01-01
Lead exposure is associated with a number of adverse health events including peripheral neuropathy, anemia, renal damage and cognitive impairment. The vast majority of adult lead exposures occur in the workplace. By statute, all results from blood lead level (BLL) tests performed in Minnesota are submitted to the Minnesota Department of Health for surveillance purposes. We analyzed that data to examine lead exposure trends from 2005 through 2012. We found that an average of 548 persons 16 years of age and older had a BLL greater than 10 μg/dL each year during that period. Analysis of the prevalence rate of elevated BLLs among adults for the years 2005-2012 showed a modest, nonsignificant decline among those with BLLs greater than 1O μg/dL. Much has been done to reduce exposures and BLLs among young children. However, the policies and standards that protect workers have not been similarly adjusted, and many workers remain at risk of exposure. Although OSHA is responsible for developing and implementing policies and standards to protect workers, health care providers can play a critical role in identifying cases of lead exposure by asking patients about their occupation and industry. Those working in high-risk industries should be tested to determine whether they have been exposed and intervention is warranted.
Behavioral determinants of occupational exposure to chemical agents.
Meijman, T F; Ulenbelt, P; Lumens, M E; Herber, R F
1996-01-01
In the demand-control model (see T. Theorell & R. A. Karasek, 1996), it is hypothesized that workers in active jobs (high demands-high decision latitude) can exert effective coping strategies when confronted with environmental stessors. Thus, when exposed to similar levels of a chemical agent, lower concentrations of this agent in blood could be expected in these workers in comparison with workers in passive jobs. This theory was tested in 2 studies of lead-exposed workers: 18 male Caucasian workers from an electric accumulatory factory and 18 male Caucasian workers from a lead smelting factory. The results did not follow the hypothesized outcomes. In the work environment of the workers in active jobs, lower concentrations of lead in air were measured, but higher levels of lead in blood were observed in these workers. The opposite was true of workers in passive jobs. Differences in hygienic behavior at work may explain these unexpected results.
NASA Astrophysics Data System (ADS)
Nepomuceno, Miguel C. S.; Lopes, Sérgio M. R.
2017-10-01
Non-destructive tests (NDT) have been used in the last decades for the assessment of in-situ quality and integrity of concrete elements. An important step in the application of NDT methods concerns to the interpretation and validation of the test results. In general, interpretation of NDT results should involve three distinct phases leading to the development of conclusions: processing of collected data, analysis of within-test variability and quantitative evaluation of property under investigation. The analysis of within-test variability can provide valuable information, since this can be compared with that of within-test variability associated with the NDT method in use, either to provide a measure of the quality control or to detect the presence of abnormal circumstances during the in-situ application. This paper reports the analysis of the experimental results of within-test variability of NDT obtained for normal vibrated concrete and self-compacting concrete. The NDT reported includes the surface hardness test, ultrasonic pulse velocity test, penetration resistance test, pull-off test, pull-out test and maturity test. The obtained results are discussed and conclusions are presented.
Ravibabu, K; Barman, T; Rajmohan, H R
2015-01-01
The interaction between serum neuron-specific enolase (NSE), biogenic amino-acids and neurobehavioral function with blood lead levels in workers exposed to lead form lead-acid battery manufacturing process was not studied. To evaluate serum NSE and biogenic amino-acids (dopamine and serotonin) levels, and neurobehavioral performance among workers exposed to lead from lead-acid storage battery plant, and its relation with blood lead levels (BLLs). In a cross-sectional study, we performed biochemical and neurobehavioral function tests on 146 workers exposed to lead from lead-acid battery manufacturing process. BLLs were assessed by an atomic absorption spectrophotometer. Serum NSE, dopamine and serotonin were measured by ELISA. Neurobehavioral functions were assessed by CDC-recommended tests---simple reaction time (SRT), symbol digit substitution test (SDST), and serial digit learning test (SDLT). There was a significant correlation (r 0.199, p<0.05) between SDST and BLL. SDLT and SRT had also a significant positive correlation (r 0.238, p<0.01). NSE had a negative correlation (r -0.194, p<0.05) with serotonin level. Multiple linear regression analysis revealed that both SRT and SDST had positive significant associations with BLL. SRT also had a positive significant association with age. Serum NSE cannot be used as a marker for BLL. The only domain of neurobehavioral function tests that is affected by increased BLL in workers of lead-acid battery manufacturing process is that of the "attention and perception" (SDST).
Susceptibility of steam generator tubes in secondary conditions: Effects of lead and sulphate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gomez Briceno, D.; Garcia, M.S.; Castano, M.L.
1997-02-01
IGA/SCC on the secondary side of steam generators is increasing every year, and represents the cause of some steam generator replacements. Until recently, caustic and acidic environments have been accepted as causes of IGA/SCC, particulary in certain environments: in sludge pile on the tube sheet; at support crevices; in free span. Lead and sulfur have been identified as significant impurities. Present thoughts are that some IGA/SCC at support crevices may have occurred in nearly neutral or mildly alkaline environments. Here the authors present experimental work aimed at studying the influence of lead and sulfur on the behaviour of steam generatormore » tube alloys in different water environments typical of steam generators. Most test results ran for at least 2000 hours, and involved visual and detailed surface analysis during and following the test procedures.« less
Developmental lead exposure has mixed effects on butterfly cognitive processes.
Philips, Kinsey H; Kobiela, Megan E; Snell-Rood, Emilie C
2017-01-01
While the effects of lead pollution have been well studied in vertebrates, it is unclear to what extent lead may negatively affect insect cognition. Lead pollution in soils can elevate lead in plant tissues, suggesting it could negatively affect neural development of insect herbivores. We used the cabbage white butterfly (Pieris rapae) as a model system to study the effect of lead pollution on insect cognitive processes, which play an important role in how insects locate and handle resources. Cabbage white butterfly larvae were reared on a 4-ppm lead diet, a concentration representative of vegetation in polluted sites; we measured eye size and performance on a foraging assay in adults. Relative to controls, lead-reared butterflies did not differ in time or ability to search for a food reward associated with a less preferred color. Indeed, lead-treated butterflies were more likely to participate in the behavioral assay itself. Lead exposure did not negatively affect survival or body size, and it actually sped up development time. The effects of lead on relative eye size varied with sex: lead tended to reduce eye size in males, but increase eye size in females. These results suggest that low levels of lead pollution may have mixed effects on butterfly vision, but only minimal impacts on performance in foraging tasks, although follow-up work is needed to test whether this result is specific to cabbage whites, which are often associated with disturbed areas.
40 CFR 230.5 - General procedures to be followed.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Evaluation and Testing (§ 230.61). (j) Identify appropriate and practicable changes to the project plan to... of illustration. The actual process followed may be iterative, with the results of one step leading...
40 CFR 230.5 - General procedures to be followed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Evaluation and Testing (§ 230.61). (j) Identify appropriate and practicable changes to the project plan to... of illustration. The actual process followed may be iterative, with the results of one step leading...
Increase in Lead Concentration in the Drinking Water of an Animal Care Facility.
Davidowitz, Bradley; Boehm, Kirk; Banovetz, Sandra; Binkley, Neil
1998-01-01
We report here the unexpected detection, and subsequent correction, of a problem that resulted in an increase in lead concentration in the drinking water of an animal research facility. At the initiation of a study, analysis of a water sample obtained from the drinking spout of an animal cage revealed a lead concentration nearly twice the Environmental Protection Agency's maximum acceptable concentration. Because the municipal water supply routinely had been tested and found to be free of lead, it was assumed that this contamination was within the animal care facility. It was hypothesized that the brass fitting connecting the drinking spout to a polyvinyl chloride (PVC) pipe was the source of contamination. Water samples were obtained hourly from 0700 to 1600 hours before and after replacement of the brass fitting with a PVC fitting. After this change, lead concentrations in all samples were within acceptable limits. Although blood lead concentrations were undetectable in 47 rhesus monkeys (Macaca mulatta) housed in the facility, subclinical lead toxicosis could have resulted and potentially complicated studies in which these monkeys were used. We recommend that the water supply of research facilities be monitored periodically.
'Battling my biology': psychological effects of genetic testing for risk of weight gain.
Meisel, S F; Wardle, J
2014-04-01
The availability of genetic tests for multifactorial conditions such as obesity raises concerns that higher-risk results could lead to fatalistic reactions or lower-risk results to complacency. No study has investigated the effects of genetic test feedback for the risk of obesity in non-clinical samples. The present study explored psychological and behavioral reactions to genetic test feedback for a weight related gene (FTO) in a volunteer sample (n = 18) using semi-structured interviews. Respondents perceived the gene test result as scientifically objective; removing some of the emotion attached to the issue of weight control. Those who were struggling with weight control reported relief of self-blame. There was no evidence for either complacency or fatalism; all respondents emphasized the importance of lifestyle choices in long-term weight management, although they recognized the role of both genes and environment. Regardless of the test result, respondents evaluated the testing positively and found it motivating and informative. Genetic test feedback for risk of weight gain may offer psychological benefits beyond its objectively limited clinical utility. As the role of genetic counselors is likely to expand, awareness of reasons for genetic testing for common, complex conditions and reactions to the test result is important.
Effect of acid rain pH on leaching behavior of cement stabilized lead-contaminated soil.
Du, Yan-Jun; Wei, Ming-Li; Reddy, Krishna R; Liu, Zhao-Peng; Jin, Fei
2014-04-30
Cement stabilization is a practical approach to remediate soils contaminated with high levels of lead. However, the potential for leaching of lead out of these stabilized soils under variable acid rain pH conditions is a major environmental concern. This study investigates the effects of acid rain on the leaching characteristics of cement stabilized lead contaminated soil under different pH conditions. Clean kaolin clay and the same soil spiked with 2% lead contamination are stabilized with cement contents of 12 and 18% and then cured for 28 days. The soil samples are then subjected to a series of accelerated leaching tests (or semi-dynamic leaching tests) using a simulated acid rain leachant prepared at pH 2.0, 4.0 or 7.0. The results show that the strongly acidic leachant (pH ∼2.0) significantly altered the leaching behavior of lead as well as calcium present in the soil. However, the differences in the leaching behavior of the soil when the leachant was mildly acidic (pH ∼4.0) and neutral (pH ∼7.0) prove to be minor. In addition, it is observed that the lead contamination and cement content levels can have a considerable impact on the leaching behavior of the soils. Overall, the leachability of lead and calcium is attributed to the stability of the hydration products and their consequent influence on the soil buffering capacity and structure. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Riley, D. R.
1985-01-01
A six-degree-of-freedom nonlinear simulation was developed for a two-place, single-engine, low-wing general aviation airplane for the stall and initial departure regions of flight. Two configurations, one with and one without an outboard wing-leading-edge modification, were modeled. The math models developed are presented simulation predictions and flight-test data for validation purposes and simulation results for the two configurations for various maneuvers and power settings are compared to show the beneficial influence of adding the wing-leading-edge modification.
Experimental study of delta wing leading-edge devices for drag reduction at high lift
NASA Technical Reports Server (NTRS)
Johnson, T. D., Jr.; Rao, D. M.
1982-01-01
The drag reduction devices selected for evaluation were the fence, slot, pylon-type vortex generator, and sharp leading-edge extension. These devices were tested on a 60 degree flatplate delta (with blunt leading edges) in the Langley Research Center 7- by 10-foot high-speed tunnel at low speed and to angles of attack of 28 degrees. Balance and static pressure measurements were taken. The results indicate that all the devices had significant drag reduction capability and improved longitudinal stability while a slight loss of lift and increased cruise drag occurred.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, T.C.; Weissman, J.C.; Varadarajan, R.
1995-12-31
A small scale biomass metal contacting experiment was performed to screen the optimal plant species for biosorption and bioaccumulation of cadmium, zinc, nickel, lead, and copper. Experiments were also conducted to test the ability of the biomass to lower the metal concentrations below the US Environmental Protection Agency surface water discharge criteria. The minimum residual concentration was 0.1 mg/L for zinc, 0.004 mg/L for lead, and about 0.01 mg/L for cadmium, nickel, and lead. Results indicate that water milfoil can be used for bioremoval of metals.
Astro-E2 Magnesium Diboride High Current Leads
NASA Technical Reports Server (NTRS)
Panek, J. S.; Tuttle, J. G.; Riall, S.; Mustafi, S.; Gray, A.; Edmonds, R.; Marrero, V.
2003-01-01
The recent discovery of superconducting properties in MgB_2 and rapid development of small diameter steel-clad wires has opened up the possibility of enhancing the design of the baseline Astro-E2 high current lead assembly. Replacing YBCO filaments with MgB_2 wires and modifying the heat sink location can give much higher margins against quench from temperature oscillations of the 4 K heat sink, although wih some overall thermal penalty. The design and performance of a new lead assembly during flight qualification is discussed, with emphasis on thermal, structural, and electrical test results.
NASA-DoD Lead-Free Electronics Project: Vibration Test
NASA Technical Reports Server (NTRS)
Woodrow, Thomas A.
2010-01-01
Vibration testing was conducted by Boeing Research and Technology (Seattle) for the NASA-DoD Lead-Free Electronics Solder Project. This project is a follow-on to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Lead-Free Solder Project which was the first group to test the reliability of lead-free solder joints against the requirements of the aerospace/miLItary community. Twenty seven test vehicles were subjected to the vibration test conditions (in two batches). The random vibration Power Spectral Density (PSD) input was increased during the test every 60 minutes in an effort to fail as many components as possible within the time allotted for the test. The solder joints on the components were electrically monitored using event detectors and any solder joint failures were recorded on a Labview-based data collection system. The number of test minutes required to fail a given component attached with SnPb solder was then compared to the number of test minutes required to fail the same component attached with lead-free solder. A complete modal analysis was conducted on one test vehicle using a laser vibrometer system which measured velocities, accelerations, and displacements at one . hundred points. The laser vibrometer data was used to determine the frequencies of the major modes of the test vehicle and the shapes of the modes. In addition, laser vibrometer data collected during the vibration test was used to calculate the strains generated by the first mode (using custom software). After completion of the testing, all of the test vehicles were visually inspected and cross sections were made. Broken component leads and other unwanted failure modes were documented.
Tin Whisker Testing and Modeling
2015-11-01
FINAL REPORT Tin Whisker Testing and Modeling SERDP Project WP-1753 NOVEMBER 2015 Stephan J. Meschter Polina Snugovsky BAE Systems...lead (Pb) is that component manufacturers have primarily switched to tin -rich finishes and solder alloys in commercial-off-the-shelf products...Unfortunately, this creates an increased risk of tin whisker formation that can result in undesirable electrical failures unless military and aerospace
ERIC Educational Resources Information Center
Krampen, Gunter
2010-01-01
The effects of relaxation exercises on orthography performance in language arts education of fifth to seventh graders were experimentally tested. Participants were 399 basic secondary school students and their language arts teachers from the Hauptschule, a German type of secondary education covering grades five to nine that leads to a basic…
Morales Bonilla, C; Mauss, E A
1998-01-01
OBJECTIVES: In response to requests by parents in Managua, Nicaragua, whose neighborhood borders a battery factory, 97 children were tested for blood lead, as were 30 children in a neighborhood without an obvious source of environmental lead. METHODS: Venous blood was examined by atomic absorption spectrophotometry. Educational workshops were conducted. RESULTS: Mean blood lead levels were 17.21 +/- 9.92 micrograms/dL in the index children and 7.40 +/- 5.37 micrograms/dL in the controls (P < .001). CONCLUSIONS: Children living near the battery factory are at increased risk of lead poisoning. The parents were able to petition the government to control the factory emissions and to improve appropriate health services. The factory is now closed. PMID:9842385
Experiences with lead/acid battery management in remote-area power-supply (RAPS) systems
NASA Astrophysics Data System (ADS)
Phillips, S. J.; Pryor, T. L.; Dymond, M. S.; Remmer, D. P.
Battery management and general storage performance and cost remain major problems in remote-area power-supply (RAPS) systems utilizing renewable energy sources. A brief review of field experiences with lead/acid batteries is presented, together with results from battery tests carried out in the laboratory. It is recommended that further collaboration between battery manufacturers and system designers is established to develop improved storage systems for RAPS applications.
Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias
2017-07-01
Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.
Manufacturing issues which affect coating erosion performance in wind turbine blades
NASA Astrophysics Data System (ADS)
Cortés, E.; Sánchez, F.; Domenech, L.; Olivares, A.; Young, T. M.; O'Carroll, A.; Chinesta, F.
2017-10-01
Erosion damage, caused by repeated rain droplet impact on the leading edges of wind turbine blades, is a major cause for cost concern. Resin Infusion (RI) is used in wind energy blades where low weight and high mechanical performance materials are demanded. The surface coating plays a crucial role in the manufacturing and performance response. The Leading Edge coating is usually moulded, painted or sprayed onto the blade surface so adequate adhesion in the layers' characterization through the thickness is required for mechanical performance and durability reasons. In the current work, an investigation has been directed into the resulting rain erosion durability of the coating was undertaken through a combination of mass loss testing measurements with manufacturing processing parameter variations. The adhesion and erosion is affected by the shock wave caused by the collapsing water droplet on impact. The stress waves are transmitted to the substrate, so microestructural discontinuities in coating layers and interfaces play a key role on its degradation. Standard industrial systems are based on a multilayer system, with a high number of interfaces that tend to accelerate erosion by delamination. Analytical and numerical models are commonly used to relate lifetime prediction and to identify suitable coating and composite substrate combinations and their potential stress reduction on the interface. In this research, the input parameters for the appropriate definition of the Cohesive Zone Modelling (CZM) of the coating-substrate interface are outlined by means of Pull off testing and Peeling testing results. It allowed one to optimize manufacturing and coating process for blades into a knowledge-based guidance for leading edge coating material development. It was achieved by investigating the erosion degradation process using both numerical and laboratory techniques (Pull off, Peeling and Rain Erosion Testing in a whirling arm rain erosion test facility).
NASA Technical Reports Server (NTRS)
Purves, L.; Strang, R. F.; Dube, M. P.; Alea, P.; Ferragut, N.; Hershfeld, D.
1983-01-01
The software and procedures of a system of programs used to generate a report of the statistical correlation between NASTRAN modal analysis results and physical tests results from modal surveys are described. Topics discussed include: a mathematical description of statistical correlation, a user's guide for generating a statistical correlation report, a programmer's guide describing the organization and functions of individual programs leading to a statistical correlation report, and a set of examples including complete listings of programs, and input and output data.
Results of chopper-controlled discharge life cycling studies on lead acid batteries
NASA Technical Reports Server (NTRS)
Ewashinka, J. G.; Sidik, S. M.
1982-01-01
A group of 108 state of the art nominally 6 volt lead acid batteries were tested in a program of one charge/discharge cycle per day for over two years or to ultimate battery failure. The primary objective was to determine battery cycle life as a function of depth of discharge (25 to 75 percent), chopper frequency (100 to 1000 Hz), duty cycle (25 to 87.5 percent), and average discharge current (20 to 260 A). The secondary objective was to determine the types of battery failure modes, if any, were due to the above parameters. The four parameters above were incorporated in a statistically designed test program.
NASA Technical Reports Server (NTRS)
Morgan, Harry L., Jr.
2002-01-01
This report describes the results of an experimental study conducted in the Langley Low-Turbulence Pressure Tunnel to determine the effects of Reynolds number and Mach number on the two-dimensional aerodynamic performance of the Langley Energy Efficient Transport (EET) High-Lift Airfoil. The high-lift airfoil was a supercritical-type airfoil with a thickness-to- chord ratio of 0.12 and was equipped with a leading-edge slat and a double-slotted trailing-edge flap. The leading-edge slat could be deflected -30 deg, -40 deg, -50 deg, and -60 deg, and the trailing-edge flaps could be deflected to 15 deg, 30 deg, 45 deg, and 60 deg. The gaps and overlaps for the slat and flaps were fixed at each deflection resulting in 16 different configurations. All 16 configurations were tested through a Reynolds number range of 2.5 to 18 million at a Mach number of 0.20. Selected configurations were also tested through a Mach number range of 0.10 to 0.35. The plotted and tabulated force, moment, and pressure data are available on the CD-ROM supplement L-18221.
Bakshi, Jayeesh
2018-04-01
Radiation exposure is a limiting factor to work in sensitive environments seen in nuclear power and test reactors, medical isotope production facilities, spent fuel handling, etc. The established choice for high radiation shielding is lead (Pb), which is toxic, heavy, and abidance by RoHS. Concrete, leaded (Pb) bricks are used as construction materials in nuclear facilities, vaults, and hot cells for radioisotope production. Existing transparent shielding such as leaded glass provides minimal shielding attenuation in radiotherapy procedures, which in some cases is not sufficient. To make working in radioactive environments more practicable while resolving the lead (Pb) issue, a transparent, lightweight, liquid, and lead-free high radiation shield-ClearView Radiation Shielding-(Radium Incorporated, 463 Dinwiddie Ave, Waynesboro, VA). was developed. This paper presents the motivation for developing ClearView, characterization of certain aspects of its use and performance, and its specific attenuation testing. Gamma attenuation testing was done using a 1.11 × 10 Bq Co source and ANSI/HPS-N 13.11 standard. Transparency with increasing thickness, time stability of liquid state, measurements of physical properties, and performance in freezing temperatures are reported. This paper also presents a comparison of ClearView with existing radiation shields. Excerpts from LaSalle nuclear power plant are included, giving additional validation. Results demonstrated and strengthened the expected performance of ClearView as a radiation shield. Due to the proprietary nature of the work, some information is withheld.
Behaviour of F82H mod. stainless steel in lead-bismuth under temperature gradient
NASA Astrophysics Data System (ADS)
Gómez Briceño, D.; Martín Muñoz, F. J.; Soler Crespo, L.; Esteban, F.; Torres, C.
2001-07-01
Austenitic steels can be used in a hybrid system in contact with liquid lead-bismuth eutectic if the region of operating temperatures is not beyond 400°C. For higher temperatures, martensitic steels are recommended. However, at long times, the interaction between the structural material and the eutectic leads to the dissolution of some elements of the steel (Ni, Cr and Fe, mainly) in the liquid metal. In a non-isothermal lead-bismuth loop, the material dissolution takes place at the hot leg of the circuit and, due to the mass transfer, deposition occurs at the cold leg. One of the possible ways to improve the performance of structural materials in lead-bismuth is the creation of an oxide layer. Tests have been performed in a small natural convection loop built of austenitic steel (316L) that has been operating for 3000 h. This loop contains a test area in which several samples of F82Hmod. martensitic steel have been tested at different times. A gas with an oxygen content of 10 ppm was bubbled in the hot area of the circuit during the operation time. The obtained results show that an oxide layer is formed on the samples introduced in the loop at the beginning of the operation and this layer increases with time. However, the samples introduced at different times during the loop operation, are not protected by oxide layers and present material dissolution in some cases.
The universe of ANA testing: a case for point-of-care ANA testing.
Konstantinov, Konstantin N; Rubin, Robert L
2017-12-01
Testing for total antinuclear antibodies (ANA) is a critical tool for diagnosis and management of autoimmune diseases at both the primary care and subspecialty settings. Repurposing of ANA from a test for lupus to a test for any autoimmune condition has driven the increase in ANA requests. Changes in ANA referral patterns include early or subclinical autoimmune disease detection in patients with low pre-test probability and use of negative ANA results to rule out underlying autoimmune disease. A positive result can lead to further diagnostic considerations. Currently, ANA tests are performed in centralized laboratories; an alternative would be ANA testing at the clinical point-of-care (POC). By virtue of its near real-time data collection capability, low cost, and ease of use, we believe the POC ANA has the potential to enable a new paradigm shift in autoimmune serology testing.
Zahrieh, David; Young, Sean G.; Oleson, Jacob; Ryckman, Kelli K.; Wels, Brian; Simmons, Donald L.; Saftlas, Audrey
2017-01-01
Lead in maternal blood can cross the placenta and result in elevated blood lead levels in newborns, potentially producing negative effects on neurocognitive function, particularly if combined with childhood lead exposure. Little research exists, however, into the burden of elevated blood lead levels in newborns, or the places and populations in which elevated lead levels are observed in newborns, particularly in rural settings. Using ~2300 dried bloods spots collected within 1–3 days of birth among Iowa newborns, linked with the area of mother’s residence at the time of birth, we examine the spatial patterns of elevated (>5 μg/dL) blood lead levels and the ecological-level predictors of elevated blood lead levels. We find that one in five newborns exceed the 5 μg/dL action level set by the US Centers for Disease Control & Prevention (CDC). Bayesian spatial zero inflated regression indicates that elevated blood lead in newborns is associated with areas of increased pre-1940s housing and childbearing-age women with low educational status in both rural and urban settings. No differences in blood lead levels or the proportion of children exceeding 5 μg/dL are observed between urban and rural maternal residence, though a spatial cluster of elevated blood lead is observed in rural counties. These characteristics can guide the recommendation for testing of infants at well-baby appointments in places where risk factors are present, potentially leading to earlier initiation of case management. The findings also suggest that rural populations are at as great of risk of elevated blood lead levels as are urban populations. Analysis of newborn dried blood spots is an important tool for lead poisoning surveillance in newborns and can direct public health efforts towards specific places and populations where lead testing and case management will have the greatest impact. PMID:28520816
NASA Technical Reports Server (NTRS)
1975-01-01
A heating array is described for testing full-scale sections of the leading edge and lower fuselage surfaces of the shuttle. The heating array was designed to provide a tool for development and acceptance testing of leading edge segments and large flat sections of the main body thermal protection system. The array was designed using a variable length module concept to meet test requirements using interchangeable components from one test configuration in another configuration. Heat generating modules and heat absorbing modules were employed to achieve the thermal gradient around the leading edge. A support was developed to hold the modules to form an envelope around a variety of leading edges; to supply coolant to each module; the support structure and to hold the modules in the flat surface heater configuration. An optical pyrometer system mounted within the array was designed to monitor specimen surface temperatures without altering the test article's surface.
Using College Admission Test Scores to Clarify High School Placement. Leading Indicator Spotlight
ERIC Educational Resources Information Center
Flug, Susanna
2010-01-01
In "Beyond Test Scores: Leading Indicators for Education," Foley and colleagues (2008) define leading indicators as those that "provide early signals of progress toward academic achievement" (p. 1) and stress that educators "need leading indicators to help them see the direction their efforts are going in and to take…
Digital electronic engine control history
NASA Technical Reports Server (NTRS)
Putnam, T. W.
1984-01-01
Full authority digital electronic engine controls (DEECs) were studied, developed, and ground tested because of projected benefits in operability, improved performance, reduced maintenance, improved reliability, and lower life cycle costs. The issues of operability and improved performance, however, are assessed in a flight test program. The DEEC on a F100 engine in an F-15 aircraft was demonstrated and evaluated. The events leading to the flight test program are chronicled and important management and technical results are identified.
Impact Testing of Orbiter Thermal Protection System Materials
NASA Technical Reports Server (NTRS)
Kerr, Justin
2006-01-01
This viewgraph presentation reviews the impact testing of the materials used in designing the shuttle orbiter thermal protection system (TPS). Pursuant to the Columbia Accident Investigation Board recommendations a testing program of the TPS system was instituted. This involved using various types of impactors in different sizes shot from various sizes and strengths guns to impact the TPS tiles and the Leading Edge Structural Subsystem (LESS). The observed damage is shown, and the resultant lessons learned are reviewed.
2014-05-16
FOR DIARRHEAL DISEASE AGENTS OF GENERA ESCHERICHIA AND SHIGELLA May 16, 2014 Reporting Period: October 1, 2010 to September 30, 2013...10-2010 - 30-09-2013 PRE-CLINICAL TESTING OF REAL-TIME PCR ASSAYS FOR DIARRHEAL DISEASE AGENTS OF GENERA ESCHERICHIA AND SHIGELLA ...Texas (MOA 2007 - 2013. Agreement No.: DODI 4000.19; AFI 25-201). Pre-clinical test results qualify ETEC and Shigella real-time PCR assays as lead
NASA Astrophysics Data System (ADS)
Winter, S.; Schmitz, F.; Clausmeyer, T.; Tekkaya, A. E.; F-X Wagner, M.
2017-03-01
In the automotive industry, advanced high strength steels (AHSS) are widely used as sheet part components to reduce weight, even though this leads to several challenges. The demand for high-quality shear cutting surfaces that do not require reworking can be fulfilled by adiabatic shear cutting: High strain rates and local temperatures lead to the formation of adiabatic shear bands (ASB). While this process is well suited to produce AHSS parts with excellent cutting surface quality, a fundamental understanding of the process is still missing today. In this study, compression tests in a Split-Hopkinson Pressure Bar with an initial strain rate of 1000 s-1 were performed in a temperature range between 200 °C and 1000 °C. The experimental results show that high strength steels with nearly the same mechanical properties at RT may possess a considerably different behavior at higher temperatures. The resulting microstructures after testing at different temperatures were analyzed by optical microscopy. The thermo-mechanical material behavior was then considered in an analytical model. To predict the local temperature increase that occurs during the adiabatic blanking process, experimentally determined flow curves were used. Furthermore, the influence of temperature evolution with respect to phase transformation is discussed. This study contributes to a more complete understanding of the relevant microstructural and thermo-mechanical mechanisms leading to the evolution of ASB during cutting of AHSS.
Appreciating Uncertainty and Personal Preference in Genetic Testing.
Kadlac, Adam
2015-01-01
Genetic testing seems to hold out hope for the cure of a number of debilitating conditions. At the same time, many people fear the information that genetic testing can make available. In this commentary, I argue that as of now, the nature of the information revealed in such tests should lead to cautious views about the value of genetic testing. Moreover, I suggest that our overall views about such testing should account for the fact that individuals place different sorts of value on the possession of their own genetic information. As a result, we should largely defer to personal preference in thinking about the propriety of genetic testing.
Wu, Wei-Te; Lin, Yu-Jen; Liou, Saou-Hsing; Yang, Chun-Yuh; Cheng, Kuang-Fu; Tsai, Perng-Jy; Wu, Trong-Neng
2012-04-01
In 1981, a Petrol-Lead Phase-Out Program (PLPOP) was launched in Taiwan for the abatement of environmental lead emissions. The present study was intended to examine whether the high Petrol-Lead Emission Areas (PLEA) would result in an increase in the incidence rate of brain cancer based on a national data bank. The national brain cancer incidence data was obtained from the Taiwan National Cancer Registry. Age standardized incidence rates were calculated based on the 2000 WHO world standard population, and gasoline consumption data was obtained from the Bureau of Energy. The differences in the trend tests for age-standardized incidence rates of brain cancer between high, median, low, and small PLEA were analyzed. A significant increase was found from small to high PLEA in age-standardized incidence rates of brain cancer. By taking six possible confounders into account, the age-standardized incidence rates for brain cancer were highly correlated with the median and high PLEA by reference to the small PLEA. After being adjusted for a number of relevant confounders, it could be concluded that high PLEA might result in an increase in the incidence rate of brain cancer resulting from high lead exposures. Copyright © 2011 Elsevier Ltd. All rights reserved.
Johnson, Sheri; Cardona, Dalila; Davis, Jeremy; Gramling, Benjamin; Hamilton, Chelsea; Hoffmann, Ray; Ruis, Sabrina; Soldat, Doug; Ventura, Steve; Yan, Ke
2016-01-01
Lead exposure is a serious health threat for children. Soil is an important exposure pathway, primarily through ingestion and inhalation. Urban agriculture is increasing. Potential environmental health risks associated with residential gardening may not be well known to community residents. A community-based participatory research (CBPR) approach was implemented to explore the relationship between urban residential vegetable gardening and lead exposure in children. The primary objectives were to characterize local backyard vegetable gardening practices, measure residential and commercial soil lead concentrations and spatial distributions, and identify priorities for individual and collective action. Participants were recruited in two stages. In phase 1, adult gardeners participated in structured interviews. In phase 2, a multistage representative sampling approach was implemented to recruit adult gardeners for interviews and soil testing. Twenty adults participated in gardening practice interviews. Adults perceive many benefits from backyard gardening and initially expressed few concerns about lead exposure risk. Results indicate that children are actively involved in backyard gardening. Total soil lead concentrations from 17 residential properties ranged from 7 to 3,234 mg kg-1(median, 187; mean, 432). Commercial soils had lead concentrations that ranged from 6 to 13 mg kg(-1) (median, 6.5; mean, 7.6). Nonparametric Mann-Whitney comparisons indicated a significant difference in lead concentration between commercial soil and residential soil (p<0.0001). Advocacy for resources needed to eliminate dangerous levels of lead from the environment, especially in communities where divestment has occurred, is enhanced through CBPR. Increasing access to soil testing is an important action step.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
In this report, the scope of the tests, the method of analysis, the results, and the conclusions are discussed. The first test indicated that the requirements generated by the Standard procedures and formulae appear to yield reasonable results, although some of the cost data provided as defaults in the Standard should be reevaluated. The second test provided experience that was useful in modifying the points compliance format, but did not uncover any procedural issues that would lead to unreasonable results. These conclusions are based on analysis using the Automated Residential Energy Standard (ARES) computer program, developed to simplify the processmore » of standards generation.« less
Oxide layer stability in lead-bismuth at high temperature
NASA Astrophysics Data System (ADS)
Martín, F. J.; Soler, L.; Hernández, F.; Gómez-Briceño, D.
2004-11-01
Materials protection by 'in situ' oxidation has been studied in stagnant lead-bismuth, with different oxygen levels (H 2/H 2O ratios of 0.3 and 0.03), at temperatures from 535 °C to 600 °C and times from 100 to 3000 h. The materials tested were the martensitic steels F82Hmod, EM10 and T91 and the austenitic stainless steels, AISI 316L and AISI 304L. The results obtained point to the existence of an apparent threshold temperature above which corrosion occurs and the formation of a protective and stable oxide layer is not possible. This threshold temperature depends on material composition, oxygen concentration in the liquid lead-bismuth and time. The threshold temperature is higher for the austenitic steels, especially for the AISI 304L, and it increases with the oxygen concentration in the lead-bismuth. The oxide layer formed disappear with time and, after 3000 h all the materials, except AISI 304L, suffer corrosion, more severe for the martensitic steels and at the highest temperature tested.
NASA Astrophysics Data System (ADS)
Hong, Bo; Jiang, Liangxing; Hao, Ketao; Liu, Fangyang; Yu, Xiaoying; Xue, Haitao; Li, Jie; Liu, Yexiang
2014-06-01
In this paper, a lightweight Pb plated Al (Al/Pb) grid was prepared by molten salt electroless plating. The SEM and bonding strength test show that the lead coating is deposited with a smooth surface and firm combination. CV test shows that the electrochemical properties of Al/Pb electrodes are stable. 2.0 V single-cell flooded lead-acid batteries with Al/Pb grids as negative collectors are assembled and the performances including 20 h capacity, rate capacity, cycle life, internal resistance are investigated. The results show that the cycle life of Al/Pb-grid cells is about 475 cycles and can meet the requirement of lead-acid batteries. Al/Pb grids are conducive to the refinement of PbSO4 grain, and thereby reduce the internal resistance of battery and advance the utilization of active mass. Moreover, weight of Al/Pb grid is only 55.4% of the conventional-grid. In this way, mass specific capacity of Al/Pb-grid negatives is 17.8% higher and the utilization of active mass is 6.5% higher than conventional-grid negatives.
NASA Technical Reports Server (NTRS)
Oliver, W. R.
1980-01-01
The development of an advanced technology high lift system for an energy efficient transport incorporating a high aspect ratio supercritical wing is described. This development is based on the results of trade studies to select the high lift system, analysis techniques utilized to design the high lift system, and results of a wind tunnel test program. The program included the first experimental low speed, high Reynolds number wind tunnel test for this class of aircraft. The experimental results include the effects on low speed aerodynamic characteristics of various leading and trailing edge devices, nacelles and pylons, aileron, spoilers, and Mach and Reynolds numbers. Results are discussed and compared with the experimental data and the various aerodynamic characteristics are estimated.
Mass Lead Intoxication from Informal Used Lead-Acid Battery Recycling in Dakar, Senegal
Haefliger, Pascal; Mathieu-Nolf, Monique; Lociciro, Stephanie; Ndiaye, Cheikh; Coly, Malang; Diouf, Amadou; Faye, Absa Lam; Sow, Aminata; Tempowski, Joanna; Pronczuk, Jenny; Junior, Antonio Pedro Filipe; Bertollini, Roberto; Neira, Maria
2009-01-01
Background and objectives Between November 2007 and March 2008, 18 children died from a rapidly progressive central nervous system disease of unexplained origin in a community involved in the recycling of used lead-acid batteries (ULAB) in the suburbs of Dakar, Senegal. We investigated the cause of these deaths. Methods Because autopsies were not possible, the investigation centered on clinical and laboratory assessments performed on 32 siblings of deceased children and 23 mothers and on 18 children and 8 adults living in the same area, complemented by environmental health investigations. Results All 81 individuals investigated were poisoned with lead, some of them severely. The blood lead level of the 50 children tested ranged from 39.8 to 613.9 μg/dL with a mean of 129.5 μg/dL. Seventeen children showed severe neurologic features of toxicity. Homes and soil in surrounding areas were heavily contaminated with lead (indoors, up to 14,000 mg/kg; outdoors, up to 302,000 mg/kg) as a result of informal ULAB recycling. Conclusions Our investigations revealed a mass lead intoxication that occurred through inhalation and ingestion of soil and dust heavily contaminated with lead as a result of informal and unsafe ULAB recycling. Circumstantial evidence suggested that most or all of the 18 deaths were due to encephalopathy resulting from severe lead intoxication. Findings also suggest that most habitants of the contaminated area, estimated at 950, are also likely to be poisoned. This highlights the severe health risks posed by informal ULAB recycling, in particular in developing countries, and emphasizes the need to strengthen national and international efforts to address this global public health problem. PMID:20019903
Performance and Reliability of Bonded Interfaces for High-Temperature Packaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paret, Paul P
2017-08-02
Sintered silver has proven to be a promising candidate for use as a die-attach and substrate-attach material in automotive power electronics components. It holds promise of greater reliability than lead-based and lead-free solders, especially at higher temperatures (>200 degrees C). Accurate predictive lifetime models of sintered silver need to be developed and its failure mechanisms thoroughly characterized before it can be deployed as a die-attach or substrate-attach material in wide-bandgap device-based packages. Mechanical characterization tests that result in stress-strain curves and accelerated tests that produce cycles-to-failure result will be conducted. Also, we present a finite element method (FEM) modeling methodologymore » that can offer greater accuracy in predicting the failure of sintered silver under accelerated thermal cycling. A fracture mechanics-based approach is adopted in the FEM model, and J-integral/thermal cycle values are computed.« less
NASA Technical Reports Server (NTRS)
Smith, P. M.
1978-01-01
Tests have been conducted to extend the existing low speed aerodynamic data base of advanced supersonic-cruise arrow wing configurations. Principle configuration variables included wing leading-edge flap deflection, wing trailing-edge flap deflection, horizontal tail effectiveness, and fuselage forebody strakes. A limited investigation was also conducted to determine the low speed aerodynamic effects due to slotted training-edge flaps. Results of this investigation demonstrate that deflecting the wing leading-edge flaps downward to suppress the wing apex vortices provides improved static longitudinal stability; however, it also results in significantly reduced static directional stability. The use of a selected fuselage forebody strakes is found to be effective in increasing the level of positive static directional stability. Drooping the fuselage nose, which is required for low-speed pilot vision, significantly improves the later-directional trim characteristics.
Bacterial challenge of NISSHO ultrafilter ETF 609: results of in vitro testing.
Krautzig, S; Lonnemann, G; Shaldon, S; Koch, K M
1996-07-01
In hemodialysis, a certain degree of bacterial contamination on the dialysate side is a regular finding. Concern has been growing that this contamination may lead to a chronic inflammatory response in the patient. Ultrafiltration of dialysate can be used to reduce bacterial content and levels of cytokine-inducing substances upstream of the patient's dialyzer. The aim of this study was to test in vitro the rejection capacity of a polysulfone hollow-fiber ultrafilter (ETF 609, NISSHO Co., Osaka, Japan) challenged with bacterial filtrates derived from Pseudomonas aeruginosa PA103. Results showed a reduction of interleukin-1 beta-inducing activity (measured on peripheral blood mononuclear cells) from 5,035 +/- 394 pg/ml prefilter to nondetectable levels postfilter and endotoxin levels (limulus amebocyte lysate assay) of 4,167 +/- 1,079 versus 12 +/- 2 pg/ml, respectively. In conclusion, ultrafiltration of dialysate with the polysulfone ultrafilter ETF 609 leads to a potent reduction of cytokine-inducing activity.
NASA Technical Reports Server (NTRS)
Davis, Richard E.; Maddalon, Dal V.; Wagner, Richard D.; Fisher, David F.; Young, Ronald
1989-01-01
Summary evaluations of the performance of laminar-flow control (LFC) leading edge test articles on a NASA JetStar aircraft are presented. Statistics, presented for the test articles' performance in haze and cloud situations, as well as in clear air, show a significant effect of cloud particle concentrations on the extent of laminar flow. The cloud particle environment was monitored by two instruments, a cloud particle spectrometer (Knollenberg probe) and a charging patch. Both instruments are evaluated as diagnostic aids for avoiding laminar-flow detrimental particle concentrations in future LFC aircraft operations. The data base covers 19 flights in the simulated airline service phase of the NASA Leading-Edge Flight-Test (LEFT) Program.
2003-01-28
Proposal Title PORTABLE TEST CELL - JETCAL 2000(R) Lead Proposer HOWELL INSTRUMENTS Military Customer NAVY/MARINE H53...B-4 Proposal Title PORTABLE TEST CELL - JETCAL 2000(R) Lead Proposer HOWELL INSTRUMENTS Military Customer...TEST CELL - JETCAL 2000(R) Lead Proposer HOWELL INSTRUMENTS Military Customer NAVY/MARINE H53 AIRCRAFT Baseline Costs -- DoD’s Costs When COSSI is NOT
Hutchinson, P L; Mahlalela, X; Yukich, Josh
2007-12-01
In this article, we examine the role of mass media and interpersonal communication in affecting knowledge of HIV/AIDS, reducing stigma, using condoms, and increasing the likelihood of disclosing HIV test results to sexual partners and family members. Data from a 2002 household survey in the Eastern Cape Province of South Africa are used to measure levels of stigma, interpersonal communication, willingness to disclosure HIV test results and condom use. We use a multilevel framework that accounts for the social context in which individuals access information, gauge social norms, and make decisions about the costs and benefits of HIV testing and disclosure. The results provide support for the positive effects of both media exposure and informal social networks on ideational factors, namely changes in knowledge and stigma, which lead to behavior change. Consistent with common models of health communication dynamics, these latter factors dominate decisions regarding disclosure of HIV test results and condom use.
Pelallo-Martínez, N A; Ilizaliturri-Hernández, C A; Espinosa-Reyes, G; Carrizales-Yáñez, L; González-Mille, D J
2011-06-01
The intake of lead from the environment may occur thru various receptors. In order to measure lead levels absorbed, samples were taken from Children who live in three localities surrounding an industrial complex in Coatzacoalcos, Veracruz. Samples were also taken from turtles. Samples were analyzed and results were compared against the general population. In children tested, over 75% of all values were determined to be above CDC's safety levels of (10 μg/dL). The geometric mean lead concentration was 11.4 μg/dL, which is clearly higher around the industrial complex than in the general population. In turtles, lead blood levels in the exposed population were 2-fold above (24.2 μg/dL) those of turtles in the reference population (10.1 μg/dL). Lead levels observed represent a risk for both human and fauna health.
Data fusion for QRS complex detection in multi-lead electrocardiogram recordings
NASA Astrophysics Data System (ADS)
Ledezma, Carlos A.; Perpiñan, Gilberto; Severeyn, Erika; Altuve, Miguel
2015-12-01
Heart diseases are the main cause of death worldwide. The first step in the diagnose of these diseases is the analysis of the electrocardiographic (ECG) signal. In turn, the ECG analysis begins with the detection of the QRS complex, which is the one with the most energy in the cardiac cycle. Numerous methods have been proposed in the bibliography for QRS complex detection, but few authors have analyzed the possibility of taking advantage of the information redundancy present in multiple ECG leads (simultaneously acquired) to produce accurate QRS detection. In our previous work we presented such an approach, proposing various data fusion techniques to combine the detections made by an algorithm on multiple ECG leads. In this paper we present further studies that show the advantages of this multi-lead detection approach, analyzing how many leads are necessary in order to observe an improvement in the detection performance. A well known QRS detection algorithm was used to test the fusion techniques on the St. Petersburg Institute of Cardiological Technics database. Results show improvement in the detection performance with as little as three leads, but the reliability of these results becomes interesting only after using seven or more leads. Results were evaluated using the detection error rate (DER). The multi-lead detection approach allows an improvement from DER = 3:04% to DER = 1:88%. Further works are to be made in order to improve the detection performance by implementing further fusion steps.
Males that drop a sexually selected weapon grow larger testes.
Joseph, Paul N; Emberts, Zachary; Sasson, Daniel A; Miller, Christine W
2018-01-01
Costly sexually selected weapons are predicted to trade off with postcopulatory traits, such as testes. Although weapons can be important for achieving access to females, individuals of some species can permanently drop (i.e. autotomize) their weapons, without regeneration, to escape danger. We capitalized on this natural behavior to experimentally address whether the loss of a sexually selected weapon leads to increased testes investment in the leaf-footed cactus bug, Narnia femorata Stål (Hemiptera: Coreidae). In a second experiment, we measured offspring production for males that lost a weapon during development. As predicted, males that dropped a hind limb during development grew significantly larger testes than the control treatments. Hind-limb autotomy did not result in the enlargement of other nearby traits. Our results are the first to experimentally demonstrate that males compensate for natural weapon loss by investing more in testes. In a second experiment we found that females paired with males that lost a hind limb had 40% lower egg hatching success than females paired with intact males, perhaps because of lower mating receptivity to males with a lost limb. Importantly, in those cases where viable offspring were produced, males missing a hind limb produced 42% more offspring than males with intact limbs. These results suggest that the loss of a hind-limb weapon can, in some cases, lead to greater fertilization success. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.
Monogenic diabetes in children and young adults: Challenges for researcher, clinician and patient
2006-01-01
Monogenic diabetes results from one or more mutations in a single gene which might hence be rare but has great impact leading to diabetes at a very young age. It has resulted in great challenges for researchers elucidating the aetiology of diabetes and related features in other organ systems, for clinicians specifying a diagnosis that leads to improved genetic counselling, predicting of clinical course and changes in treatment, and for patients to altered treatment that has lead to coming off insulin and injections with no alternative (Glucokinase mutations), insulin injections being replaced by tablets (e.g. low dose in HNFα or high dose in potassium channel defects -Kir6.2 and SUR1) or with tablets in addition to insulin (e.g. metformin in insulin resistant syndromes). Genetic testing requires guidance to test for what gene especially given limited resources. Monogenic diabetes should be considered in any diabetic patient who has features inconsistent with their current diagnosis (unspecified neonatal diabetes, type 1 or type 2 diabetes) and clinical features of a specific subtype of monogenic diabetes (neonatal diabetes, familial diabetes, mild hyperglycaemia, syndromes). Guidance is given by clinical and physiological features in patient and family and the likelihood of the proposed mutation altering clinical care. In this article, I aimed to provide insight in the genes and mutations involved in insulin synthesis, secretion, and resistance, and to provide guidance for genetic testing by showing the clinical and physiological features and tests for each specified diagnosis as well as the opportunities for treatment. PMID:17186387
Temperature-dependent plastic hysteresis in highly confined polycrystalline Nb films
NASA Astrophysics Data System (ADS)
Waheed, S.; Hao, R.; Zheng, Z.; Wheeler, J. M.; Michler, J.; Balint, D. S.; Giuliani, F.
2018-02-01
In this study, the effect of temperature on the cyclic deformation behaviour of a confined polycrystalline Nb film is investigated. Micropillars encapsulating a thin niobium interlayer are deformed under cyclic axial compression at different test temperatures. A distinct plastic hysteresis is observed for samples tested at elevated temperatures, whereas negligible plastic hysteresis is observed for samples tested at room temperature. These results are interpreted using planar discrete dislocation plasticity incorporating slip transmission across grain boundaries. The effect of temperature-dependent grain boundary energy and dislocation mobility on dislocation penetration and, consequently, the size of plastic hysteresis is simulated to correlate with the experimental results. It is found that the decrease in grain boundary energy barrier caused by the increase in temperature does not lead to any appreciable change in the cyclic response. However, dislocation mobility significantly affects the size of plastic hysteresis, with high mobilities leading to a larger hysteresis. Therefore, it is postulated that the experimental observations are predominantly caused by an increase in dislocation mobility as the temperature is increased above the critical temperature of body-centred cubic niobium.
Miguel, Elizabeth L M; Silva, Poliana L; Pliego, Josefredo R
2014-05-29
Methanol is a widely used solvent for chemical reactions and has solvation properties similar to those of water. However, the performance of continuum solvation models in this solvent has not been tested yet. In this report, we have investigated the performance of the SM8 and SMD models for pKa prediction of 26 carboxylic acids, 24 phenols, and 23 amines in methanol. The gas phase contribution was included at the X3LYP/TZVPP+diff//X3LYP/DZV+P(d) level. Using the proton exchange reaction with acetic acid, phenol, and ammonia as reference species leads to RMS error in the range of 1.4 to 3.6 pKa units. This finding suggests that the performance of the continuum models for methanol is similar to that found for aqueous solvent. Application of simple empirical correction through a linear equation leads to accurate pKa prediction, with uncertainty less than 0.8 units with the SM8 method. Testing with the less expensive PBE1PBE/6-311+G** method results in a slight improvement in the results.
Measured and predicted pressure distributions on the AFTI/F-111 mission adaptive wing
NASA Technical Reports Server (NTRS)
Webb, Lannie D.; Mccain, William E.; Rose, Lucinda A.
1988-01-01
Flight tests have been conducted using an F-111 aircraft modified with a mission adaptive wing (MAW). The MAW has variable-camber leading and trailing edge surfaces that can change the wing camber in flight, while preserving smooth upper surface contours. This paper contains wing surface pressure measurements obtained during flight tests at Dryden Flight Research Facility of NASA Ames Research Center. Upper and lower surface steady pressure distributions were measured along four streamwise rows of static pressure orifices on the right wing for a leading-edge sweep angle of 26 deg. The airplane, wing, instrumentation, and test conditions are discussed. Steady pressure results are presented for selected wing camber deflections flown at subsonic Mach numbers up to 0.90 and an angle-of-attack range of 5 to 12 deg. The Reynolds number was 26 million, based on the mean aerodynamic chord. The MAW flight data are compared to MAW wind tunnel data, transonic aircraft technology (TACT) flight data, and predicted pressure distributions. The results provide a unique database for a smooth, variable-camber, advanced supercritical wing.
Advanced Crew Escape Suits (ACES): Particle Impact Test
NASA Technical Reports Server (NTRS)
Rosales, Keisa R.; Stoltzfus, Joel M.
2009-01-01
NASA Johnson Space Center (JSC) requested NASA JSC White Sands Test Facility to assist in determining the effects of impaired anodization on aluminum parts in advanced crew escape suits (ACES). Initial investigation indicated poor anodization could lead to an increased risk of particle impact ignition, and a lack of data was prevalent for particle impact of bare (unanodized) aluminum; therefore, particle impact tests were performed. A total of 179 subsonic and 60 supersonic tests were performed with no ignition of the aluminum targets. Based on the resulting test data, WSTF found no increased particle impact hazard was present in the ACES equipment.
Jang, Yong-Chul; Townsend, Timothy G
2003-10-15
The proper management of discarded electronic devices (E-waste) is an important issue for solid waste professionals because of the magnitude of the waste stream and because these devices often contain a variety of toxic metals (e.g., lead). While recycling of E-waste is developing, much of this waste stream is disposed in landfills. Leaching tests are frequently used to characterize the potential of a solid waste to leach when disposed in a landfill. In the United States, the Toxicity Characteristic Leaching Procedure (TCLP) is used to determine whether a solid waste is a hazardous waste by the toxicity characteristic. The TCLP is designed to simulate worse-case leaching in a landfill environment where the waste is co-disposed with municipal solid waste (MSW). While the TCLP is a required analysis from a regulatory perspective, the leachate concentrations measured may not accurately reflect the concentrations observed under typical landfill conditions. Another method that can be performed to assess the degree a pollutant might leach from a waste in a landfill is to use actual landfill leachate as the leaching solution. In this study, two lead-containing components found in electronic devices (printed wire boards from computers and cathode ray tubes from computers and televisions) were leached using the TCLP and leachates from 11 Florida landfills. California's Waste Extraction Test (WET) and the Synthetic Precipitation Leaching Procedure were also performed. The results indicated that the extractions using MSW landfill leachates resulted in lower lead concentrations than those by the TCLP. The pH of the leaching solution and the ability of the organic acids in the TCLP and WET to complex with the lead are factors that regulate the amount of lead leached.
Raizada, Neeraj; Sachdeva, Kuldeep Singh; Sreenivas, Achuthan; Kulsange, Shubhangi; Gupta, Radhey Shyam; Thakur, Rahul; Dewan, Puneet; Boehme, Catharina; Paramsivan, Chinnambedu Nainarappan
2015-01-01
Background A critical challenge in providing TB care to People Living with HIV (PLHIV) is establishing an accurate bacteriological diagnosis. Xpert MTB/RIF, a highly sensitive and specific rapid tool, offers a promising solution in addressing these challenges. This study presents results from PLHIV taking part in a large demonstration study across India wherein upfront Xpert MTB/RIF testing was offered to all presumptive PTB cases in public health facilities. Method The study covered a population of 8.8 million across 18 sub-district level tuberculosis units (TU), with one Xpert MTB/RIF platform established at each TU. All HIV-infected patients suspected of TB (both TB and Drug Resistant TB (DR-TB)) accessing public health facilities in study area were prospectively enrolled and provided upfront Xpert MTB/RIF testing. Result 2,787 HIV-infected presumptive pulmonary TB cases were enrolled and 867 (31.1%, 95% Confidence Interval (CI) 29.4‒32.8) HIV-infected TB cases were diagnosed under the study. Overall 27.6% (CI 25.9–29.3) of HIV-infected presumptive PTB cases were positive by Xpert MTB/RIF, compared with 12.9% (CI 11.6–14.1) who had positive sputum smears. Upfront Xpert MTB/RIF testing of presumptive PTB and DR-TB cases resulted in diagnosis of 73 (9.5%, CI 7.6‒11.8) and 16 (11.2%, CI 6.7‒17.1) rifampicin resistance cases, respectively. Positive predictive value (PPV) for rifampicin resistance detection was high 97.7% (CI 89.3‒99.8), with no significant difference with or without prior history of TB treatment. Conclusion The study results strongly demonstrate limitations of using smear microscopy for TB diagnosis in PLHIV, leading to low TB and DR-TB detection which can potentially lead to either delayed or sub-optimal TB treatment. Our findings demonstrate the usefulness and feasibility of addressing this diagnostic gap with upfront of Xpert MTB/RIF testing, leading to overall strengthening of care and support package for PLHIV. PMID:25658091
Kosky, Christopher A.; Bonakis, Anastasios; Yogendran, Arthee; Hettiarachchi, Gihan; Dargan, Paul I.; Williams, Adrian J.
2016-01-01
Study Objectives: Drugs and psychoactive substances can cause sleepiness and when undetected, may lead to over diagnosis of central hypersomnias. We performed urine drug testing using gas chromatography-mass spectrometry in adults undergoing multiple sleep latency testing (MSLT) for a suspected central hypersomnia. We examined how the drug test results modified the treating physician's diagnosis. Methods: One hundred eighty-six consecutive patients with a suspected central hypersomnia who underwent clinical assessment, MSLT and urine drug testing by gas chromatography-mass spectrometry were retrospectively studied. Physicians made a diagnosis after clinical assessment and MSLT and were initially blinded to the urine drug test results. Results: A third of patients assessed for subjective hypersomnia had a positive urine drug test for a substance affecting sleep. Opioids, cannabis, and amphetamines were the commonest drugs detected. Using MSLT, 35 (18.8%) of 186 patients had objective hypersomnia that may have been due to a drug or substance. Drugs or substances may have confounded the MSLT in 11 (20.1%) of 53 patients who fulfilled diagnostic criteria for idiopathic hypersomnia, and 12 (52%) of 23 of those who fulfilled diagnostic criteria for narcolepsy without cataplexy. Of the 75 positive urine drug samples, 61 (81%) were substances or medications not revealed in the physician interview. The treating physician had not suspected drugs or substances as a possible cause of objective hypersomnia in 34 (97%) of the 35 patients. Conclusions: Drugs and psychoactive substances can confound the results of the MSLT and when undetected could lead to over diagnosis of central hypersomnias. Citation: Kosky CA, Bonakis A, Yogendran A, Hettiarachchi G, Dargan PI, Williams AJ. Urine toxicology in adults evaluated for a central hypersomnia and how the results modify the physician's diagnosis. J Clin Sleep Med 2016;12(11):1499–1505. PMID:27568897
... Childhood Exposures to Lead. CDC MMWR 56(RR08);1-14;16 [On-line information]. Available online at http://www.cdc.gov/mmwr/preview/mmwrhtml/rr5608a1.htm. Accessed June 2009. (Revised 2007 August 20). Case Studies in Environmental Medicine (CSEM), Lead Toxicity, What Tests ...
The local lymph node assay being too sensitive?
Hans-Werner, Vohr; Jürgen, Ahr Hans
2005-12-01
The local lymph node assay (LLNA) and modifications thereof were recently recognized by the OECD as stand-alone methods for the detection of skin-sensitizing potential. However, although the validity of the LLNA was acknowledged by the ICCVAM, attention was drawn to one major problem, i.e., the possibility of false positive results caused by non-specific cell activation as a result of inflammatory processes in the skin (irritation). This is based on the fact that inflammatory processes in the skin may lead to non-specific activation of dendritic cells, cell migration and non-specific proliferation of lymph node cells. Measuring cell proliferation by radioactive or non-radioactive methods, without taking the irritating properties of test items into account, leads thus to false positive reactions. In this paper, we have compared both endpoints: (1) cell proliferation alone and (2) cell proliferation in combination with inflammatory (irritating) processes. It turned out that a considerable number of tests were "false positive" to the definition mentioned above. By excluding such false positive results the LLNA seems not to be more sensitive than relevant guinea pig assays. These various methods and results are described here.
A possibility of avoiding surface roughness due to insects
NASA Technical Reports Server (NTRS)
Wortmann, F. X.
1984-01-01
Discussion of a method for eliminating turbulence caused by the formation of insect roughness upon the leading edges and fuselage, particularly in aircraft using BLC. The proposed technique foresees the use of elastic surfaces on which insect roughness cannot form. The operational characteristics of highly elastic rubber surface fastened to the wing leading edges and fuselage edges are examined. Some preliminary test results are presented. The technique is seen to be advantageous primarily for short-haul operations.
[Thyroid and cardiovascular disorders].
Zyśko, Dorota; Gajek, Jacek
2004-05-01
In this study three problems concerning interactions between thyroid and cardiovascular system are discussed. Cardiac arrhythmias, congestive heart failure, pleural effusion, hyperlipidaemia, arterial hypertension may be consequences of thyroid disorders leading to inappropriate hormone secretion. During such illnesses as heart failure, myocardial infarction and in patients undergoing coronary artery bypass surgery profound changes may occur in thyroid hormone metabolism known as sick euthyroid syndrome. Treatment with amiodarone may lead to changes in thyroid tests results and to development of hypothyroidism or thyrotoxicosis.
ERIC Educational Resources Information Center
Flores, Alina L.; Prue, Christine E.; Panissidi, Paula
2010-01-01
Objective: This article presents the results of testing draft folic acid educational materials with key gatekeepers, leading to the development of a Spanish-language print advertisement, poster, and radio public service announcement (PSA) aimed at promoting folic acid consumption among 18- to 25-year-old young Latina adults, as well as a…
NASA Astrophysics Data System (ADS)
Kachalin, G. V.; Mednikov, A. F.; Tkhabisimov, A. B.; Arkad'ev, D. A.; Temkin, S. G.; Senina, N. A.
2016-12-01
Fatigue test results of the rotating steel blades of the fourth stage of the K-25-0.6 low pressure cylinder Geo steam turbine manufactured in the Kaluga Turbine Plant (hereinafter, KTP) with the ion-plasma coating were presented. Coating formation was carried out at the National Research University (MPEI) on the Gefest vacuum pilot plant by the magnetron sputtering method. Characteristics of the obtained coating were analyzed with the use of the scientific-research equipment of the National Research University (MPEI). Fatigue tests of the rotating blades and determination of the fatigue strength of the material with the ion-plasma coating were carried out on the electrodynamic vibration machines VEDS-400A in the KTP structural laboratory. The following characteristics were obtained after tests: Ti-TiN composition, 10-11 μm thickness, 1200 HV 0.05 microhardness. Fatigue tests showed that destruction, regardless of availability or nonavailability of the coating, took place by cross-section in the root zone both on the leading and trailing edges of the blade, i.e., in the most stressed zones. It was found out that the maximum stresses during tests were revealed in the root section along the trailing edge on the blade pressure side, and the less stresses were on the leading edge. Fatigue strength of the working blades after coating formation increased by 12% minimum. Results of the fatigue tests prove the previously obtained data concerning 10-12% increase of the fatigue strength of the blade steel with the ion-plasma coating and allow claiming that the process of their formation exerts the positive influence on the fatigue characteristics of the blade materials.
Delinquency and Peer Acceptance in Adolescence: A Within-Person Test of Moffitt’s Hypotheses
Rulison, Kelly L; Kreager, Derek A.; Osgood, D. Wayne
2015-01-01
We tested two hypotheses derived from Moffitt’s (1993) taxonomic theory of antisocial behavior, both of which are central to her explanation for the rise in delinquency during adolescence. Specifically, we tested whether persistently delinquent individuals become more accepted by their peers during adolescence and whether individuals who abstain from delinquent behavior become less accepted. Participants were 4,359 adolescents from 14 communities in the PROSPER study, which assessed friendship networks and delinquency from 6th (M = 11.8 years) to 9th (M = 15.3 years) grade. We operationalized peer acceptance as: number of nominations received (indegree centrality), attractiveness as a friend (adjusted indegree centrality), and network bridging potential (betweenness centrality) and tested the hypotheses using multilevel modeling. Contrary to Moffitt’s hypothesis, persistently delinquent youth did not become more accepted between early and middle adolescence, and although abstainers were less accepted in early adolescence, they became more accepted over time. Results were similar for boys and girls; when differences occurred, they provided no support for Moffitt’s hypotheses for boys and were opposite of her hypotheses for girls. Sensitivity analyses using alternative strategies and additional data to identify persistently delinquent adolescents produced similar results. We explore the implications of these results for Moffitt’s assertions that social mimicry of persistently antisocial adolescents leads to increases in delinquency and that social isolation leads to abstention. PMID:25243328
Evaluation of recombinant proteins of Burkholderia mallei for serodiagnosis of glanders.
Pal, Vijai; Kumar, Subodh; Malik, Praveen; Rai, Ganga Prasad
2012-08-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders.
Evaluation of Recombinant Proteins of Burkholderia mallei for Serodiagnosis of Glanders
Kumar, Subodh; Malik, Praveen
2012-01-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders. PMID:22695165
KEITH HIGGINBOTHAM AT TEST STAND 4699
2016-10-17
KEITH HIGGINBOTHAM, STRUCTURAL TEST LEAD FOR THE SLS SPACECRAFT PAYLOAD INTEGRATION AND EVOLUTION OFFICE, IS SHOWN BESIDE TEST STAND 4699 AT THE MARSHALL SPACE FLIGHT CENTER’S WEST TEST AREA. HIGGINBOTHAM WILL BE LEADING STRUCTURAL LOADS TESTING AT TEST STAND 4699 FOR THE CORE STAGE SIMULATER AND THE LAUNCH VEHICLE STAGE ADAPTER. THE TEST SERIES WILL ENSURE EACH STRUCTURE CAN WITHSTAND THE INCREDIBLE STRESSES OF LAUNCH.
... Agendas, and Minutes New Blood Lead Level Information Funding Information Lead in Drinking Water Lead-based Water Lines Washington, D.C. Blood Lead Level Tests Effect of Previously Missing Blood Lead Level (BPb) Surveillance ...
The Division of Labor, Technology, and Education: Cross-National Evidence
ERIC Educational Resources Information Center
Grandjean, Burke D.
1974-01-01
The author provides data on 29 countries to test the hypothesis of Durkheim, Marx, and Adam Smith that the division of labor and technological development lead to expanded education. The results support the above thesis. (Author/DE)
Results of low power deicer tests on a swept inlet component in the NASA Lewis icing research tunnel
NASA Technical Reports Server (NTRS)
Bond, Thomas H.; Shin, Jaiwon
1993-01-01
Tests were conducted under a USAF/NASA Low Power Deicer program on two expulsive technologies to examine system performance on hardware representative of a modern aircraft part. The BF Goodrich Electro-Expulsive Deicing System and Pneumatic Impulse Ice Protection System were installed on a swept, compound curve, engine inlet component with varying leading edge radius, and tested through a range of icing and system operating conditions in the NASA Lewis Icing Research Tunnel. A description of the experimental procedure and results, including residual ice thickness, shed ice particle size, and changes in system energy/pressure characteristics are presented.
Results of Low Power Deicer tests on a swept inlet component in the NASA Lewis Icing Research Tunnel
NASA Technical Reports Server (NTRS)
Bond, Thomas H.; Shin, Jaiwon
1993-01-01
Tests were conducted under a USAF/NASA Low Power Deicer program on two expulsive technologies to examine system performance on hardware representative of a modern aircraft part. The BF Goodrich Electro-Expulsive Deicing System and Pneumatic Impulse Ice Protection system were installed on a swept, compound curve, engine inlet component with varying leading edge radius, and tested through a range of icing and system operating conditions in the NASA Lewis Icing Research Tunnel. A description of the experimental procedure and results, including residual ice thickness, shed ice particle size, and changes in system energy/pressure characteristics are presented.
Baseline tests of the EPC Hummingbird electric passenger vehicle
NASA Technical Reports Server (NTRS)
Slavik, R. J.; Maslowski, E. A.; Sargent, N. B.; Birchenough, A. G.
1977-01-01
The rear-mounted internal combustion engine in a four-passenger Volkswagen Thing was replaced with an electric motor made by modifying an aircraft generator and powered by 12 heavy-duty, lead-acid battery modules. Vehicle performance tests were conducted to measure vehicle maximum speed, range at constant speed, range over stop-and-go driving schedules, maximum acceleration, gradeability limit, road energy consumption, road power, indicated energy consumption, braking capability, battery charger efficiency, and battery characteristics. Test results are presented in tables and charts.
Development of airframe design technology for crashworthiness.
NASA Technical Reports Server (NTRS)
Kruszewski, E. T.; Thomson, R. G.
1973-01-01
This paper describes the NASA portion of a joint FAA-NASA General Aviation Crashworthiness Program leading to the development of improved crashworthiness design technology. The objectives of the program are to develop analytical technology for predicting crashworthiness of structures, provide design improvements, and perform full-scale crash tests. The analytical techniques which are being developed both in-house and under contract are described, and typical results from these analytical programs are shown. In addition, the full-scale testing facility and test program are discussed.
Development of a Pulsed Pressure-Based Technique for Cavitation Damage Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Fei; Wang, Jy-An John; Liu, Yun
2012-01-01
Cavitation occurs in many fluid systems and can lead to severe material damage. To assist the study of cavitation damage, a novel testing method utilizing pulsed pressure was developed. In this talk, the scientific background and the technical approach of this development are present and preliminary testing results are discussed. It is expected that this technique can be used to evaluate cavitation damage under various testing conditions including harsh environments such as those relevant to geothermal power generation.
Pineau, Alain; Otz, Jocelyne; Guillard, Olivier; Fauconneau, Bernard; Dumont, Gilles; François-Burg, Elisabeth
2014-01-01
In 1992, at the request of the French labor ministry following questions on the ability of medical biology laboratories to satisfactorily measure blood lead level (PbB), a national PbB quality control came into being. Only in 1996 did this external quality control include a number of laboratories sufficient to allow for a significant retrospective evaluation. After fifteen years (1996-2011), The French National Agency for Medicines and Health Products Safety wished to exploit the database collected. The number of participating laboratories went down from 73 to 41. On the other hand, the key finding pertained to the highly improved performance of the laboratories, which was associated with a spread decrease of the results over the entire range of tested PbBs (9 to 700 μg/L). Since 2006, we have observed increasing use of the inductively coupled plasma with mass spectrometry and decreasing use of electrothermal atomic absorption spectrometry. Provided that they rely on identical metrology expertise, the two analytical techniques lead to results on all the tested concentrations that are not statistically different.
Cole, Laurence A; Khanlian, Sarah A
2004-05-01
False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.
ERIC Educational Resources Information Center
Natale, Jo Anna
1991-01-01
Recent research shows lead poisoning is more widespread and even more dangerous to infants and young children than previously thought. A bill proposed in Congress would require schools and day-care centers to test for lead. Summarizes lead's health hazards and how to test drinking water. (MLF)
Soleimani, Elham; Goudarzi, Iran; Abrari, Kataneh; Lashkarbolouki, Taghi
2017-05-01
Melatonin is a radical scavenger with the ability to remove reactive oxidant species. There is report that co-exposure to lead and ethanol during developmental stages induces learning and memory deficits and oxidative stress. Here, we studied the effect of melatonin, with strong antioxidant properties, on memory deficits induced by lead and ethanol co-exposure and oxidative stress in hippocampus. Pregnant rats in lead and ethanol co-exposure group received lead acetate of 0.2% in distilled drinking water and ethanol (4g/kg) by oral gavages once daily from the 5th day of gestation until weaning. Rats received 10mg/kg melatonin by oral gavages. On postnatal days (PD) 30, rats trained with six trials per day for 6 consecutive days in the water maze. On day 37, a probe test was done and oxidative stress markers in the hippocampus were evaluated. Results demonstrated lead and ethanol co-exposed rats exhibited higher escape latency during training trials and reduced time spent in target quadrant, higher escape location latency in probe trial test and had significantly higher malondialdehyde (MDA) levels, significantly lower superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPx) activities in the hippocampus. Melatonin treatment could improve memory deficits, antioxidants activity and reduced MDA levels in the hippocampus. We conclude, co-exposure to lead and ethanol impair memory and melatonin can prevent from it by oxidative stress modulation. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Lyle, Karen H.
2008-01-01
The Space Shuttle Columbia Accident Investigation Board recommended that NASA develop, validate, and maintain a modeling tool capable of predicting the damage threshold for debris impacts on the Space Shuttle Reinforced Carbon-Carbon (RCC) wing leading edge and nosecap assembly. The results presented in this paper are one part of a multi-level approach that supported the development of the predictive tool used to recertify the shuttle for flight following the Columbia Accident. The assessment of predictive capability was largely based on test analysis comparisons for simpler component structures. This paper provides comparisons of finite element simulations with test data for external tank foam debris impacts onto 6-in. square RCC flat panels. Both quantitative displacement and qualitative damage assessment correlations are provided. The comparisons show good agreement and provided the Space Shuttle Program with confidence in the predictive tool.
NASA Technical Reports Server (NTRS)
Premont, E. J.; Stubenrauch, K. R.
1973-01-01
The resistance of current-design Pratt and Whitney Aircraft low aspect ratio advanced fiber reinforced epoxy matrix composite fan blades to foreign object damage (FOD) at STOL operating conditions was investigated. Five graphite/epoxy and five boron/epoxy wide chord fan blades with nickel plated stainless steel leading edge sheath protection were fabricated and impact tested. The fan blades were individually tested in a vacuum whirlpit under FOD environments. The FOD environments were typical of those encountered in service operations. The impact objects were ice balls, gravel, stralings and gelatin simulated birds. Results of the damage sustained from each FOD impact are presented for both the graphite boron reinforced blades. Tests showed that the present design composite fan blades, with wrap around leading edge protection have inadequate FOD impact resistance at 244 m/sec (800 ft/sec) tip speed, a possible STOL operating condition.
Simulations of Wakes and Parachute Environments for Supersonic Flight Test Design
NASA Astrophysics Data System (ADS)
Muppidi, Suman; O'Farrell, Clara; van Norman, John; Clark, Ian
2017-11-01
NASA's ASPIRE (Advanced Supersonic Parachute Inflation Research and Experiments) project is a risk-reduction activity for a future mission, Mars2020. ASPIRE will investigate the supersonic deployment, inflation and aerodynamics of a full-scale disk-gap-band (DGB) parachute in the wake of a slender body at high altitudes over Earth. The leading slender body has about 1/6-th the diameter of the entry capsule that will use this parachute for descent at Mars. ASPIRE flight test design (targeting, safety and recovery) requires models for deployment, inflation and aerodynamic performance of the parachute. However, there is limited flight and experimental data for supersonic DGBs behind slender bodies. This presentation describes the use of CFD in supplementing the available data to construct a parachute aerodynamics model for ASPIRE. Simulations are used to understand the effects of the leading body on the wake, and on the canopy loads, results of which will be presented. The first flight test is scheduled for September 2017. Comparisons of preliminary test data against the pre-test parachute model will be presented.
Repeatability and uncertainty analyses of light gas gun test data
NASA Technical Reports Server (NTRS)
Schonberg, William P.; Cooper, David
1994-01-01
All large spacecraft are susceptible to high-speed impacts by meteoroids and pieces of orbiting space debris which can damage flight-critical systems and in turn lead to catastrophic failure. One way to obtain information on the response of a structure to a meteoroid impact or an orbital debris impact is to simulate the impact conditions of interest in the laboratory and analyze the resulting damage to a target structure. As part of the Phase B and C/D development activities for the Space Station Freedom, 950 impact tests were performed using the NASA/Marshall Space Flight Center (MSFC) light gas gun from 1985-1991. This paper presents the results of impact phenomena repeatability and data uncertainty studies performed using the information obtained from those tests. The results of these studies can be used to assess the utility of individual current and future NASA/MSFC impact test results in the design of long-duration spacecraft.
Zika Virus Testing and Outcomes during Pregnancy, Florida, USA, 2016
Shiu, Colette; Starker, Rebecca; Kwal, Jaclyn; Bartlett, Michelle; Crane, Anise; Greissman, Samantha; Gunaratne, Naiomi; Lardy, Meghan; Picon, Michelle; Rodriguez, Patricia; Gonzalez, Ivan
2018-01-01
Zika virus infection during pregnancy can lead to congenital Zika syndrome. Implementation of screening programs and interpretation of test results can be particularly challenging during ongoing local mosquitoborne transmission. We conducted a retrospective chart review of 2,327 pregnant women screened for Zika virus in Miami–Dade County, Florida, USA, during 2016. Of these, 86 had laboratory evidence of Zika virus infection; we describe 2 infants with probable congenital Zika syndrome. Delays in receipt of laboratory test results (median 42 days) occurred during the first month of local transmission. Odds of screening positive for Zika virus were higher for women without health insurance or who did not speak English. Our findings indicate the increase in screening for Zika virus can overwhelm hospital and public health systems, resulting in delayed receipt of results of screening and confirmatory tests and the potential to miss cases or delay diagnoses. PMID:29260671
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-16
... Third Party Testing for Lead Content, Phthalate Content, and the Solubility of the Eight Elements Listed... toys primarily intended for children 12 years old and younger, the lead content must be no greater than 100 parts per million (ppm), and the lead content of paints or surface coatings must be no greater...
Assessment of Proper Bonding Methods and Mechanical Characterization FPGA CQFPs
NASA Technical Reports Server (NTRS)
Davis, Milton C.
2008-01-01
This presentation discusses fractured leads on field-programmable gate array (FPGA) during flight vibration. Actions taken to determine root cause and resolution of the failure include finite element analysis (FEA) and vibration testing and scanning electron microscopy (with X-ray microanalysis) and energy dispersive spectrometry (SEM/EDS) failure assessment. Bonding methods for surface mount parts is assessed, including critical analysis and assessment of random fatigue damage. Regarding ceramic quad flat pack (CQFP) lead fracture, after disassembling the attitude control electronics (ACE) configuration, photographs showed six leads cracked on FPGA RTSX72SU-1 CQ208B package located on the RWIC card. An identical package (FPGA RTSX32SU-1 CQ208B) mounted on the RWIC did not results in cracked pins due to vibration. FPGA lead failure theories include workmanship issues in the lead-forming, material defect in the leads of the FPGA packages, and the insecure mounting of the board in the card guides, among other theories. Studies were conducted using simple calculations to determine the response and fatigue life of the package. Shorter packages exhibited more response when loaded by out-of-plane displacement of PCB while taller packages exhibit more response when loaded by in-plane acceleration of PCB. Additionally, under-fill did not contribute to reducing stress in leads due to out-of-plane PCB loading or from component twisting, as much as corner bonding. The combination of corner bond and under-fill is best to address mechanical and thermal S/C environment. Test results of bonded parts showed reduced (dampened) amplitude and slightly shifted peaks at the un-bonded natural frequency and an additional response at the bonded frequency. Stress due to PCBB out-of-plane loading was decreased on in the corners when only a corner bond was used. Future work may address CQFP fatigue assessment, including the investigation of discrepancy in predicted fatigue damage, as well as comparing fatigue life and fatigue damage cycle ration computed using FEA and Miner's rule to results from a fatigue assessment software program.
A computational study of incipient leading-edge separation on a 65-deg delta wing at M = 1.60
NASA Technical Reports Server (NTRS)
Mcmillin, S. Naomi; Pittman, James L.; Thomas, James L.
1990-01-01
A computational study on a 65-deg delta wing at a freestream Mach number of 1.60 has been conducted by obtaining conical Reynolds-averaged Navier-Stokes solutions on a parametric series of geometries which varied in leading-edge radius and/or circular-arc camber. The computational results showed that increasing leading-edge radius or camber can delay the onset of leading-edge separation on the leeside of a delta wing at a specific angle of attack. Reynolds number was varied from 1 x 10 to the 6th to 5 x 10 to the 6th for a turbulent boundary-layer and was shown to have a minor effect on the effectiveness of leading-edge radius and/or camber in delaying the onset of leading-edge separation. Both laminar and turbulent boundary-layer models were investigated at a Reynolds number of 1 x 10 to the 6th, and the predicted flow pattern was found to change from attached flow for the turbulent boundary-layer model to separated flow for the laminar boundary-layer model. Based upon these results, three wind-tunnel models have been designed to be tested in the Langley Unitary Plan Wind Tunnel.
NASA Technical Reports Server (NTRS)
Johnson, J. L., Jr.; Newsom, W. A.; Satran, D. R.
1980-01-01
The paper presents the results of a recent investigation to determine the effects of wing leading-edge modifications on the high angle-of-attack aerodynamic characteristics of a low-wing general aviation airplane in the Langley Full-Scale Wind Tunnel. The investigation was conducted to provide aerodynamic information for correlation and analysis of flight-test results obtained for the configuration. The wind-tunnel investigation consisted of force and moment measurements, wing pressure measurements, flow surveys, and flow visualization studies utilizing a tuft grid, smoke and nonintrusive mini-tufts which were illuminated by ultra-violet light. In addition to the tunnel scale system which measured overall forces and moments, the model was equipped with an auxiliary strain-gage balance within the left wing panel to measure lift and drag forces on the outer wing panel independent of the tunnel scale system. The leading-edge modifications studied included partial- and full-span leading-edge droop arrangements as well as leading-edge slats.
Intelligent lead: a novel HRI sensor for guide robots.
Cho, Keum-Bae; Lee, Beom-Hee
2012-01-01
This paper addresses the introduction of a new Human Robot Interaction (HRI) sensor for guide robots. Guide robots for geriatric patients or the visually impaired should follow user's control command, keeping a certain desired distance allowing the user to work freely. Therefore, it is necessary to acquire control commands and a user's position on a real-time basis. We suggest a new sensor fusion system to achieve this objective and we will call this sensor the "intelligent lead". The objective of the intelligent lead is to acquire a stable distance from the user to the robot, speed-control volume and turn-control volume, even when the robot platform with the intelligent lead is shaken on uneven ground. In this paper we explain a precise Extended Kalman Filter (EKF) procedure for this. The intelligent lead physically consists of a Kinect sensor, the serial linkage attached with eight rotary encoders, and an IMU (Inertial Measurement Unit) and their measurements are fused by the EKF. A mobile robot was designed to test the performance of the proposed sensor system. After installing the intelligent lead in the mobile robot, several tests are conducted to verify that the mobile robot with the intelligent lead is capable of achieving its goal points while maintaining the appropriate distance between the robot and the user. The results show that we can use the intelligent lead proposed in this paper as a new HRI sensor joined a joystick and a distance measure in the mobile environments such as the robot and the user are moving at the same time.
Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus
NASA Technical Reports Server (NTRS)
Russell, Carl R.
2014-01-01
A shake test of the Large Rotor Test Apparatus (LRTA) was performed in an effort to enhance NASAscapability to measure dynamic hub loads for full-scale rotor tests. This paper documents the results of theshake test as well as efforts to calibrate the LRTA balance system to measure dynamic loads.Dynamic rotor loads are the primary source of vibration in helicopters and other rotorcraft, leading topassenger discomfort and damage due to fatigue of aircraft components. There are novel methods beingdeveloped to reduce rotor vibrations, but measuring the actual vibration reductions on full-scale rotorsremains a challenge. In order to measure rotor forces on the LRTA, a balance system in the non-rotatingframe is used. The forces at the balance can then be translated to the hub reference frame to measure therotor loads. Because the LRTA has its own dynamic response, the balance system must be calibrated toinclude the natural frequencies of the test rig.
Performance characteristics and statistics of a laser initiated microdetonator
NASA Technical Reports Server (NTRS)
Yang, L. C.
1979-01-01
The test results of 320 units of the laser initiated microdetonator are summarized. The commercially fabricated units used a lead styphnate/lead azide/HMX (1 mg/17.5 mg/13.5 mg) explosive train design contained in a miniature aluminum can and completed with a glass-metal seal window. The test parameters were the high and low laser energy, high and low temperature, laser pulse duration, laser wavelength and nuclear radiation (5 x 10 to the 6th rads of 1 MeV gamma ray). The performance parameters were the laser energy for ignition and the actuation response time. Included also is a description of the development of a flexible, continuously advanced train of explosive devices by using the units, miniature optics and fiber optics.
Hamilton, Maryellen; Geraci, Lisa
2006-01-01
According to leading theories, the picture superiority effect is driven by conceptual processing, yet this effect has been difficult to obtain using conceptual implicit memory tests. We hypothesized that the picture superiority effect results from conceptual processing of a picture's distinctive features rather than a picture's semantic features. To test this hypothesis, we used 2 conceptual implicit general knowledge tests; one cued conceptually distinctive features (e.g., "What animal has large eyes?") and the other cued semantic features (e.g., "What animal is the figurehead of Tootsie Roll?"). Results showed a picture superiority effect only on the conceptual test using distinctive cues, supporting our hypothesis that this effect is mediated by conceptual processing of a picture's distinctive features.
Current Lead Design for the Accelerator Project for Upgrade of LHC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandt, Jeffrey S.; Cheban, Sergey; Feher, Sandor
2010-01-01
The Accelerator Project for Upgrade of LHC (APUL) is a U.S. project participating in and contributing to CERN's Large Hadron Collider (LHC) upgrade program. In collaboration with Brookhaven National Laboratory, Fermilab is developing sub-systems for an upgrade of the LHC final focus magnet systems. A concept of main and auxiliary helium flow was developed that allows the superconductor to remain cold while the lead body warms up to prevent upper section frosting. The auxiliary flow will subsequently cool the thermal shields of the feed box and the transmission line cryostats. A thermal analysis of the current lead central heat exchangemore » section was performed using analytic and FEA techniques. A method of remote soldering was developed that allows the current leads to be field replaceable. The remote solder joint was designed to be made without flux or additional solder, and able to be remade up to ten full cycles. A method of upper section attachment was developed that allows high pressure sealing of the helium volume. Test fixtures for both remote soldering and upper section attachment for the 13 kA lead were produced. The cooling concept, thermal analyses, and test results from both remote soldering and upper section attachment fixtures are presented.« less
High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging
NASA Technical Reports Server (NTRS)
2004-01-01
Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.
Tuakuila, Joel; Kabamba, Martin; Mata, Honoré; Mata, Gerard
2013-04-04
The phasing out of lead from gasoline has resulted in a significant decrease in blood lead levels (BLLs) in children during the last two decades. Tetraethyl lead was phased out in DRC in 2009. The objective of this study was to test for reduction in pediatric BLLs in Kinshasa, by comparing BLLs collected in 2011 (2 years after use of leaded gasoline was phased out) to those collected in surveys conducted in 2004 and 2008 by Tuakuila et al. (when leaded gasoline was still used). We analyzed BLLs in a total of 100 children under 6 years of age (Mean ± SD: 2.9 ± 1.6 age, 64% boys) using inductively coupled argon plasma mass spectrometry (ICP - MS). The prevalence of elevated BLLs (≥ 10 μg/dL) in children tested was 63% in 2004 [n = 100, GM (95% CI) = 12.4 μg/dL (11.4 - 13.3)] and 71% in 2008 [(n = 55, GM (95% CI) = 11.2 μg/dL (10.3 - 14.4)]. In the present study, this prevalence was 41%. The average BLLs for the current study population [GM (95% CI) = 8.7 μg/dL (8.0 - 9.5)] was lower than those found by Tuakuila et al. (F = 10.38, p <0.001) as well as the CDC level of concern (10 μ/dL), with 3% of children diagnosed with BLLs ≥ 20 μg/dL. These results demonstrate a significant success of the public health system in Kinshasa, DRC-achieved by the removal of lead from gasoline. However, with increasing evidence that adverse health effects occur at BLLs < 10 μg/dL and no safe BLLs in children has been identified, the BLLs measured in this study continue to constitute a major public health concern for Kinshasa. The emphasis should shift to examine the contributions of non-gasoline sources to children's BLLs: car batteries recycling in certain residences, the traditional use of fired clay for the treatment of gastritis by pregnant women and leaded paint.
The psychological impact of genetic testing on parents.
Dinc, Leyla; Terzioglu, Fusun
2006-01-01
The aim of this descriptive study was to explore the psychological impact of genetic testing on parents whose children have been referred for genetic testing. Genetic tests enable individuals to be informed about their health status and to have the opportunity of early diagnosis and treatment of their diseases. However undergoing genetic testing and receiving a positive test result may also cause stress and anxiety. This descriptive study was carried out at the genetic departments of two university hospitals in Ankara. The sample of this study consisted of 128 individuals whose children have been referred for chromosomal analysis. Data were collected through using a semi-structured interview method with a data collection form and the anxiety inventory and analysed using the percentages and independent samples t-test. The majority of our participants experienced distress before genetic testing. Their general trait anxiety score before receiving the test results was 47.38, and following the test results the state anxiety score was 50.65. Having a previous child with an abnormality, a positive test result, and being a mother elevated the anxiety of individuals. This paper supports the findings of previous studies, which indicated that genetic test results might lead to anxiety in individuals and reveals the importance of genetic counselling. As the results of this study indicated, genetic testing causes distress and anxiety in individuals. Nurses can play an important role in minimizing anxiety of parents whose children undergo genetic testing by providing information about genetic testing and by taking part in the counselling process.
MDOT innovation leading to faster, longer-lasting pavement repairs : research spotlight.
DOT National Transportation Integrated Search
2015-01-01
Current methods of patching pavement must evolve to meet increasing mobility demands. : To address this need, MDOT has been testing a new generation of rapid set full-depth : pavement repair materials. Initial results are promising. The new materials...
40 CFR 278.3 - Criteria for use of chat in Federally funded transportation projects.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., incorporated by reference in § 260.11 of this chapter, and the leachate testing results show that concentrations in the leachate do not exceed the National Primary Drinking Water Standards for lead and cadmium...
40 CFR 278.3 - Criteria for use of chat in Federally funded transportation projects.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., incorporated by reference in § 260.11 of this chapter, and the leachate testing results show that concentrations in the leachate do not exceed the National Primary Drinking Water Standards for lead and cadmium...
40 CFR 278.3 - Criteria for use of chat in Federally funded transportation projects.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., incorporated by reference in § 260.11 of this chapter, and the leachate testing results show that concentrations in the leachate do not exceed the National Primary Drinking Water Standards for lead and cadmium...
40 CFR 278.3 - Criteria for use of chat in Federally funded transportation projects.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., incorporated by reference in § 260.11 of this chapter, and the leachate testing results show that concentrations in the leachate do not exceed the National Primary Drinking Water Standards for lead and cadmium...
Kašuba, V; Rozgaj, R; Milić, M; Zelježić, D; Kopjar, N; Pizent, A; Kljaković-Gašpić, Z; Jazbec, A
2012-10-01
We investigated genotoxic effects of occupational exposure to lead acetate in pottery-glaze ceramic workers. The study was carried out in 30 exposed workers and 30 matched controls, to whom several biochemical parameters-the blood lead (B-Pb; range: exposed, 41.68-404.77; controls, 12-52) and cadmium (B-Cd) level, the activity of delta-aminolevulinic acid dehydratase (ALAD), erythrocyte protoporphyrin (EP), the level of vitamin B(12) and folate in serum-were measured. The genotoxic effects were evaluated by the alkaline comet assay, the DNA diffusion assay and micronucleus test in peripheral blood lymphocytes. Subjects exposed to lead had significantly higher B-Pb level and, consequently, increased values of tail intensity (TI), frequency of apoptotic and necrotic cells, and frequency of micronuclei (MN). In contrast, their activity of ALAD, the level of vitamin B(12) and folate in serum were significantly lower compared to controls. Poisson regression analysis showed a significant correlation of profession, duration of exposure, smoking, level of cadmium in blood, ALAD and EP with primary DNA damage. A majority of primary damage repairs in a short period after exposure to a genotoxic agent. In addition, the influence of gender and level of vitamin B(12) and folate in serum MN frequency in exposed group was observed. In this study, DNA diffusion and micronucleus test showed higher influence of tested parameters to DNA damage. The results indicate a need for concomitant use of at least two different biomarkers of exposure when estimating a genetic risk of lead exposure.
Guidelines for evaluation and treatment of lead poisoning of wild raptors
Fallon, Jesse A.; Redig, Patrick; Miller, Tricia A.; Lanzone, Michael J.; Katzner, Todd
2017-01-01
Lead poisoning is a threat to birds, particularly scavenging birds of prey. With the availability of portable lead-testing kits, an increasing number of field researchers are testing wild-caught birds, in situ, for lead poisoning. We describe guidelines for evaluation of lead toxicity in wild raptors by outlining field testing of blood-lead concentrations, presenting criteria for removing a lead-poisoned bird from the wild for treatment, and suggesting strategies for effective treatment of lead intoxicated raptors. Field testing of birds is most commonly accomplished via portable electrochemical analysis of blood; visual observation of condition alone may provide insufficient evidence upon which to make a decision about lead poisoning. Our intended audience is not only the avian research community, but also rehabilitation facilities that may receive apparently uninjured birds. Best practices suggest that birds whose blood-lead levels are <40 μg/dL be released back to the wild as soon as possible after capture. The decision to release or treat birds with blood-lead levels between 40 μg/dL and 60 μg/dL should be made based on the presence of clinical signs of poisoning and relevant biological characteristics (e.g., breeding status). Finally, birds with blood-lead levels >60 μg/dL are potentially lethally poisoned and best served if removed from the wild for appropriate treatment at a licensed rehabilitation facility and later released. We present guidelines for decision-making when treating lead poisoning of wild raptors. Future work based on experimental studies will clarify the role of lead poisoning for specific species and be important to refine these guidelines to improve effectiveness.
Faisal, Ayad A H; Abd Ali, Ziad T
2017-10-01
Computer solutions (COMSOL) Multiphysics 3.5a software was used for simulating the one-dimensional equilibrium transport of the lead-phenol binary system including the sorption process through saturated sandy soil as the aquifer and granular dead anaerobic sludge (GDAS) as the permeable reactive barrier. Fourier-transform infrared spectroscopy analysis proved that the carboxylic and alcohol groups are responsible for the bio-sorption of lead onto GDAS, while phosphines, aromatic and alkane are the functional groups responsible for the bio-sorption of phenol. Batch tests have been performed to characterize the equilibrium sorption properties of the GDAS and sandy soil in lead and/or phenol containing aqueous solutions. Numerical and experimental results proved that the barrier plays a potential role in the restriction of the contaminant plume migration and there is a linear relationship between longevity and thickness of the barrier. A good agreement between these results was recognized with root mean squared error not exceeding 0.04.
Wind tunnel investigations of glider fuselages with different waistings and wing arrangements
NASA Technical Reports Server (NTRS)
Radespiel, R.
1983-01-01
The parameters fuselage pinch glider wing arrangement and fuselage leading edge radius of nine glider configurations were investigated in wind tunnel tests. Laminar separation bubbles were found on strongly recessed fuselages. These separations in the juncture between fuselage and wing are essential in the prevention of harmful aerodynamic drag. Drag reduction was measured with increasing pinch and the wing arrangement in the rear. These results are only valid for laminar flow on the fuselage leading edge.
[Discovery and follow-up of a lead-poisoning outbreak in a shantytown of Le Port, Reunion Island].
Solet, J-L; Renault, P; Denys, J-C; Teulé, G; Dennemont, R-M; Domonte, F; Garnier, C; Aubert, L; Filleul, L; Polycarpe, D
2013-08-01
A national survey conducted in 2008-2009 by the French Institute for Public Health Surveillance for detection of lead impact in childhood identified a high blood lead level in a young boy living in the town of "Le Port", Reunion Island. Previously, cases of lead-poisoning on the island had been exceptional; only a dozen cases were reported in the 1980s in adults, related to the use of lead-containing instruments for food preparations. The family of the index case was invited to participate in screening tests and an environmental investigation was conducted using a standardized questionnaire. Screening was then broadened to the neighborhood of the index case and samples of soil outside the home and in the immediate vicinity were taken. The environmental survey was then extended with soil samples taken from the entire geographical area. Information was then provided to local inhabitants (87 families and 287 people) in order to encourage lead blood testing for all children under six years and all pregnant women living in the area. The index case lived in the neighborhood of "The Oasis", a shantytown of Le Port. The results of soil analysis revealed heterogeneous pollution of superficial soils by lead throughout the area of the shantytown, the highest level recorded (5200mg/kg) reached more than 300 times the background level of the natural soils of the island. The screening identified 76 cases of childhood lead-poisoning (blood lead level greater or equal to 100μg/L) among 148 samples (51%). All cases of blood poisoning involved children under the age of 15 years. The median age of children with a positive test was 5.6 years; the median blood lead level was 196μg/L [102-392μg/L]. The main hypothesis to explain the contamination of the soil in the area of the shantytown is the presence of waste deposits (car batteries) and diffuse activities of metal recovery. The authorities managed to remove all the families from the environmental exposure to lead by rapidly ensuring rehousing outside the contaminated area. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Effects of information type on children's interrogative suggestibility: is Theory-of-Mind involved?
Hünefeldt, Thomas; Rossi-Arnaud, Clelia; Furia, Augusta
2009-08-01
This research was aimed at learning more about the different psychological mechanisms underlying children's suggestibility to leading questions, on the one hand, and children's suggestibility to negative feedback, on the other, by distinguishing between interview questions concerning different types of information. Results showed that, unlike the developmental pattern of children's suggestibility to leading questions, the developmental pattern of children's suggestibility to negative feedback differed depending on whether the interview questions concerned external facts (physical states and events) or internal facts (mental states and events). This difference was not manifested in response to questions concerning central versus peripheral facts. Results are interpreted in terms of the hypothesis that children's suggestibility to negative feedback is differently affected by "Theory-of-Mind" abilities than children's suggestibility to leading questions. Further research is needed in order to test this hypothesis.
Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav
2017-09-01
Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T
2016-02-01
The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.
Asteroid mass estimation with Markov-chain Monte Carlo
NASA Astrophysics Data System (ADS)
Siltala, Lauri; Granvik, Mikael
2017-10-01
Estimates for asteroid masses are based on their gravitational perturbations on the orbits of other objects such as Mars, spacecraft, or other asteroids and/or their satellites. In the case of asteroid-asteroid perturbations, this leads to a 13-dimensional inverse problem at minimum where the aim is to derive the mass of the perturbing asteroid and six orbital elements for both the perturbing asteroid and the test asteroid by fitting their trajectories to their observed positions. The fitting has typically been carried out with linearized methods such as the least-squares method. These methods need to make certain assumptions regarding the shape of the probability distributions of the model parameters. This is problematic as these assumptions have not been validated. We have developed a new Markov-chain Monte Carlo method for mass estimation which does not require an assumption regarding the shape of the parameter distribution. Recently, we have implemented several upgrades to our MCMC method including improved schemes for handling observational errors and outlier data alongside the option to consider multiple perturbers and/or test asteroids simultaneously. These upgrades promise significantly improved results: based on two separate results for (19) Fortuna with different test asteroids we previously hypothesized that simultaneous use of both test asteroids would lead to an improved result similar to the average literature value for (19) Fortuna with substantially reduced uncertainties. Our upgraded algorithm indeed finds a result essentially equal to the literature value for this asteroid, confirming our previous hypothesis. Here we show these new results for (19) Fortuna and other example cases, and compare our results to previous estimates. Finally, we discuss our plans to improve our algorithm further, particularly in connection with Gaia.
ERIC Educational Resources Information Center
Puhan, Gautam; vonDavier, Alina; Gupta, Shaloo
2008-01-01
Equating under the external anchor design is frequently conducted using scaled scores on the anchor test. However, scaled scores often lead to the unique problem of creating zero frequencies in the score distribution because there may not always be a one-to-one correspondence between raw and scaled scores. For example, raw scores of 17 and 18 may…
Kahle, L R; Kulka, R A; Klingel, D M
1980-09-01
This article reports the results of a study that annually monitored the self-esteem and interpersonal problems of over 100 boys during their sophomore, junior, and senior years of high school. Cross-lagged panel correlation differences show that low self-esteem leads to interpersonal problems in all three time lags when multiple interpersonal problems constitute the dependent variable but not when single interpersonal problem criteria constitute the dependent variable. These results are interpreted as supporting social-adaptation theory rather than self-perception theory. Implications for the conceptual status of personality variables as causal antecedents and for the assessment of individual differences are discussed.
Design and test of voltage and current probes for EAST ICRF antenna impedance measurement
NASA Astrophysics Data System (ADS)
Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG
2018-04-01
On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L < 1.5 Ω, which implies that the power loss cannot be neglected at high VSWR. As the factors that give rise to the deviation of coupling resistance calculation, the phase measurement error is the more significant factor leads to deleterious results rather than the amplitude measurement error. To exclude the possible ingredients that may lead to phase measurement error, the phase detector can be calibrated in steady L-mode scenario and then use the calibrated data for calculation under H-mode cases in EAST experiments.
Arno, Sally; Bell, Christopher P; Uquillas, Carlos; Borukhov, Ilya; Walker, Peter S
2015-04-01
The purpose of this study was to determine if a horizontal cleavage lesion (HCL) of the posterior horn of the medial meniscus would result in changes to tibiofemoral contact mechanics, as measured by peak contact pressure and contact area, which can lead to cartilage degeneration. To study this, 10 cadaveric knees were tested in a rig where forces were applied (500 N Compression, 100 N shear, 2.5 Nm Torque) and the knee dynamically flexed from -5° to 135°, as peak contact pressure and contact area were recorded. After testing of the intact knee, a horizontal cleavage lesion was created arthroscopically and testing repeated. The Wilcoxon signed-rank test was used to determine if there were differences in peak contact pressure and contact area between the intact knee and that with the HCL. A statistically significant increase in peak contact pressure of 13%, on average, and a decrease in contact area of 6%, on average, was noted following the HCL. This suggests that a horizontal cleavage lesion will result in small but statistically significant changes in tibiofemoral contact mechanics which may lead to cartilage degeneration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
VIIRS-J1 Polarization Narrative
NASA Technical Reports Server (NTRS)
Waluschka, Eugene; McCorkel, Joel; McIntire, Jeff; Moyer, David; McAndrew, Brendan; Brown, Steven W.; Lykke, Keith; Butler, James; Meister, Gerhard; Thome, Kurtis J.
2015-01-01
The VIS/NIR bands polarization sensitivity of Joint Polar Satellite Sensor 1 (JPSS1) Visible/Infrared Imaging Radiometer Suite (VIIRS) instrument was measured using a broadband source. While polarization sensitivity for bands M5-M7, I1, and I2 was less than 2.5%, the maximum polarization sensitivity for bands M1, M2, M3, and M4 was measured to be 6.4%, 4.4%, 3.1%, and 4.3%, respectively with a polarization characterization uncertainty of less than 0.3%. A detailed polarization model indicated that the large polarization sensitivity observed in the M1 to M4 bands was mainly due to the large polarization sensitivity introduced at the leading and trailing edges of the newly manufactured VISNIR bandpass focal plane filters installed in front of the VISNIR detectors. This was confirmed by polarization measurements of bands M1 and M4 bands using monochromatic light. Discussed are the activities leading up to and including the instruments two polarization tests, some discussion of the polarization model and the model results, the role of the focal plane filters, the polarization testing of the Aft-Optics-Assembly, the testing of the polarizers at Goddard and NIST and the use of NIST's T-SIRCUS for polarization testing and associated analyses and results.
Shah, Ashesh; Coste, Jérôme; Lemaire, Jean-Jacques; Taub, Ethan; Schüpbach, W M Michael; Pollo, Claudio; Schkommodau, Erik; Guzman, Raphael; Hemm-Ode, Simone
2017-05-01
Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a new, versatile method for quantitative intraoperative evaluation of improvement in tremor with an acceleration sensor that is mounted on the patient's wrist during surgery. At each anatomical test position, the improvement in tremor compared to the initial tremor is estimated on the basis of extracted outcome measures. This method was tested on 15 tremor patients undergoing DBS surgery in two centers. Data from 359 stimulation tests were acquired. Our results suggest that accelerometric evaluation detects tremor changes more sensitively than subjective visual ratings. The effective stimulation current amplitudes identified from the quantitative data (1.1 ± 0.8 mA) are lower than those identified by visual evaluation (1.7 ± 0.8 mA) for similar improvement in tremor. Additionally, if these data had been used to choose the chronic implant position of the DBS lead, 15 of the 26 choices would have been different. These results show that our method of accelerometric evaluation can potentially improve DBS targeting.
Ampule tests to simulate glass corrosion in ambient temperature lithium batteries. Volume 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Douglas, S.C.; Bunker, B.C.; Crafts, C.C.
1984-06-01
Glass corrosion in battery headers has been found to limit the shelf life of ambient temperature lithium batteries. Glass corrosion can lead to loss of battery electrolytes or to shorts across the conductive corrosion product. Tests have been conducted which simulate the corrosive environment in a battery by sealing headers attached to lithium metal into Pyrex ampules containing battery electrolyte. Using the ampule test, glass corrosion kinetics have been determined at 70/sup 0/C for the Li/SO/sub 2/, Li/SOCl/sub 2/, and Li/SOCl/sub 2/ + BrCl battery systems. Test results indicate that corrosion of commercial glass compositions is extensive in all electrolytesmore » tested, resulting in predicted battery failures after several months. Sandia's TA-23 glass corrodes at a much slower rate, indicating a projected battery lifetime of over five years in the Li/SO/sub 2/ system. Test results reveal that corrosion kinetics are sensitive to header polarization, stress, and configuration as well as glass composition.« less
On the study of wavy leading-edge vanes to achieve low fan interaction noise
NASA Astrophysics Data System (ADS)
Tong, Fan; Qiao, Weiyang; Xu, Kunbo; Wang, Liangfeng; Chen, Weijie; Wang, Xunnian
2018-04-01
The application of wavy leading-edge vanes to reduce a single-stage axial fan noise is numerically studied. The aerodynamic and acoustic performance of the fan is numerically investigated using a hybrid unsteady Reynolds averaged Navier-Stokes (URANS)/acoustic analogy method (Goldstein equations). First, the hybrid URANS/Goldstein method is developed and successfully validated against experiment results. Next, numerical simulations are performed to investigate the noise reduction effects of the wavy leading-edge vanes. The aerodynamic and acoustic performance is assessed for a fan with vanes equipped with two different wavy leading-edge profiles and compared with the performance of conventional straight leading-edge vanes. Results indicate that a fan with wavy leading-edge vanes produces lower interaction noise than the baseline fan without a significant loss in aerodynamic performance. In fact, it is demonstrated that wavy leading-edge vanes have the potential to lead to both aerodynamic and acoustic improvements. The two different wavy leading-edge profiles are shown to successfully reduce the fan tone sound power level by 1.2 dB and 4.3 dB, respectively. Fan efficiency is also improved by about 1% with one of the tested wavy leading-edge profiles. Large eddy simulation (LES) is also performed for a simplified fan stage model to assess the effects of wavy leading-edge vanes on the broadband fan noise. Results indicate that the overall sound power level of a fan can be reduced by about 4 dB with the larger wavy leading-edge profile. Finally, the noise reduction mechanisms are investigated and analysed. It is found that the wavy leading-edge profiles can induce significant streamwise vorticity around the leading-edge protuberances and reduce pressure fluctuations (especially at locations of wavy leading-edge hills) and unsteady forces on the stator vanes. The underlying mechanism of the reduced pressure fluctuations is also discussed by examining the magnitude-squared coherence between the velocity and pressure fluctuations in the vicinity of the noise sources. Moreover, a reduction in the correlation level of the wall pressure fluctuations along the vane leading-edge is observed, as well as destructive phase interference along the vane leading-edge.
Analysis of lead toxicity in human cells
2012-01-01
Background Lead is a metal with many recognized adverse health side effects, and yet the molecular processes underlying lead toxicity are still poorly understood. Quantifying the injurious effects of lead is also difficult because of the diagnostic limitations that exist when analyzing human blood and urine specimens for lead toxicity. Results We analyzed the deleterious impact of lead on human cells by measuring its effects on cytokine production and gene expression in peripheral blood mononuclear cells. Lead activates the secretion of the chemokine IL-8 and impacts mitogen-dependent activation by increasing the secretion of the proinflammatory cytokines IL-6 and TNF-α and of the chemokines IL-8 and MIP1-α in the presence of phytohemagglutinin. The recorded changes in gene expression affected major cellular functions, including metallothionein expression, and the expression of cellular metabolic enzymes and protein kinase activity. The expression of 31 genes remained elevated after the removal of lead from the testing medium thereby allowing for the measurement of adverse health effects of lead poisoning. These included thirteen metallothionein transcripts, three endothelial receptor B transcripts and a number of transcripts which encode cellular metabolic enzymes. Cellular responses to lead correlated with blood lead levels and were significantly altered in individuals with higher lead content resultantly affecting the nervous system, the negative regulation of transcription and the induction of apoptosis. In addition, we identified changes in gene expression in individuals with elevated zinc protoporphyrin blood levels and found that genes regulating the transmission of nerve impulses were affected in these individuals. The affected pathways were G-protein mediated signaling, gap junction signaling, synaptic long-term potentiation, neuropathic pain signaling as well as CREB signaling in neurons. Cellular responses to lead were altered in subjects with high zinc protoporphyrin blood levels. Conclusions The results of our study defined specific changes in gene and protein expression in response to lead challenges and determined the injurious effects of exposures to lead on a cellular level. This information can be used for documenting the health effects of exposures to lead which will facilitate identifying and monitoring efficacious treatments for lead-related maladies. PMID:22839698
Methods for measuring plating thicknesses on TAB lead frames
NASA Technical Reports Server (NTRS)
Hagen, M. P.
1977-01-01
Plating three layer tape lead frames, used for tape automated bonding, offers a challenge to the electroplater because of nonuniform topography. Each lead frame contains large (typically .05 x. .05 inch) flat test pads located around the perimeter of the frame. These test pads are electrically connected to the bondable lead frame fingers which extend into an area in the center of the frame called the feature hole. The feature hole exposes these fingers to plating on all sides, while the test pads are exposed on only one side. In addition, the fingers are small in cross section (typically .003 x .0015 inches). Recent thickness measurements indicate that plating around the lead frame fingers is nearly twice as thick as that on test pad areas. Procedures and equipment were developed for measuring the thickness of the deposited material. Discussion was centered on the data obtained using the various measurement techniques and equipment.
[Cement augmentation on the spine : Biomechanical considerations].
Kolb, J P; Weiser, L; Kueny, R A; Huber, G; Rueger, J M; Lehmann, W
2015-09-01
Vertebral compression fractures are the most common osteoporotic fractures. Since the introduction of vertebroplasty and screw augmentation, the management of osteoporotic fractures has changed significantly. The biomechanical characteristics of the risk of adjacent fractures and novel treatment modalities for osteoporotic vertebral fractures, including pure cement augmentation by vertebroplasty, and cement augmentation of screws for posterior instrumentation, are explored. Eighteen human osteoporotic lumbar spines (L1-5) adjacent to vertebral bodies after vertebroplasty were tested in a servo-hydraulic machine. As augmentation compounds we used standard cement and a modified low-strength cement. Different anchoring pedicle screws were tested with and without cement augmentation in another cohort of human specimens with a simple pull-out test and a fatigue test that better reflects physiological conditions. Cement augmentation in the osteoporotic spine leads to greater biomechanical stability. However, change in vertebral stiffness resulted in alterations with the risk of adjacent fractures. By using a less firm cement compound, the risk of adjacent fractures is significantly reduced. Both screw augmentation techniques resulted in a significant increase in the withdrawal force compared with the group without cement. Augmentation using perforated screws showed the highest stability in the fatigue test. The augmentation of cement leads to a significant change in the biomechanical properties. Differences in the stability of adjacent vertebral bodies increase the risk of adjacent fractures, which could be mitigated by a modified cement compound with reduced strength. Screws that were specifically designed for cement application displayed greatest stability in the fatigue test.
... Agendas, and Minutes New Blood Lead Level Information Funding Information Lead in Drinking Water Lead-based Water Lines Washington, D.C. Blood Lead Level Tests Effect of Previously Missing Blood Lead Level (BPb) Surveillance ...
... Agendas, and Minutes New Blood Lead Level Information Funding Information Lead in Drinking Water Lead-based Water Lines Washington, D.C. Blood Lead Level Tests Effect of Previously Missing Blood Lead Level (BPb) Surveillance ...
Derivation of mechanical characteristics for Ni/Au intermetallic surface with SAC305 solder
NASA Astrophysics Data System (ADS)
Kim, Jong-Min; Lee, Hyun-Boo; Chang, Yoon-Suk; Choi, Jae-Boong
2013-03-01
Many surface finish methods are used to connect a substrate with the electric components of IT products in the micro-packaging process, and various types of lead-free solder have been developed as alternative materials to lead-based solder to reduce environmental contamination. However, there has been little research on the mechanical properties of the inter-metallic surface which is generated in the bumping process between the lead-free solder and surface films such as Ni/Au. The present work is to derive the material properties of a Ni/Au inter-metallic surface with SAC305 solder. A series of indentation tests were carried out by changing four nano-scale indentation depths and two strain rates. Also, a reverse algorithm method was adopted to determine the elastic-plastic stress-strain curve based on the load-displacement curve from the indentation test data. As a result of the material characterization effort, the mean elastic modulus, yield strength and strain hardening exponent of IMC with Ni/Au finish were determined.
Lycopersicon esculentum (Tomato) Prevents Adverse Effects of Lead on Blood Constituents
SALAWU, Emmanuel O
2010-01-01
Background: Lead is known for its adverse effects on various organs and systems. In this study, the ability of lead to adversely affect blood parameters was investigated, and Lycopersicon esculentum, or commonly known as tomato (a source of antioxidants), was administered orally in the form of tomato paste (TP) to reduce the adverse effects of lead. Methods: The study involved 56 Wistar rats divided equally into 4 groups of 14 rats each: Control, LAG, TPG, and LA+TPG. Control and TPG rats were given distilled water ad libitum, while LAG and LA+TPG rats were given 1% lead (II) acetate (LA) per day. TPG and LA+TPG rats were additionally treated with 1.5 ml of TP per day. All treatments lasted for 10 weeks, after which the rats were weighed and sacrificed, and haematological and biochemical parameters were measured. The independent samples t test was used to analyse the results. Results: Lead caused significant reductions in the following parameters: weight; packed cell volume; red blood cell and white blood cell counts; the percentages of lymphocytes and monocytes; total serum protein, albumin, and globulin levels; and plasma superoxide dismutase and catalase activities. In contrast, lead caused a significant increase in the percentage of neutrophils and the plasma malondialdehyde concentration. TP, however, significantly prevented the adverse effects of LA. Conclusion: The oral administration of TP prevents the adverse effects of lead on blood constituents. PMID:22135544
Testing of a Loop Heat Pipe Subjective to Variable Accelerations. Part 2; Temperature Stability
NASA Technical Reports Server (NTRS)
Ku, Jentung; Ottenstein, Laura; Kaya, Taril; Rogers, Paul; Hoff, Craig
2000-01-01
The effect of accelerating forces on the performance of loop heat pipes (LHP) is of interest and importance to terrestrial and space applications. LHP's are being considered for cooling of military combat vehicles and for spinning spacecraft. In order to investigate the effect of an accelerating force on LHP operation, a miniature LHP was installed on a spin table. Variable accelerating forces were imposed on the LHP by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting accelerations ranged from 1.17 g's to 4.7 g's. This paper presents the second part of the experimental study, i.e. the effect of an accelerating force on the LHP operating temperature. It has been known that in stationary tests the LHP operating temperature is a function of the evaporator power and the condenser sink temperature when the compensation temperature is not actively controlled. Results of this test program indicate that any change in the accelerating force will result in a chance in the LHP operating temperature through its influence on the fluid distribution in the evaporator, condenser and compensation chamber. However, the effect is not universal, rather it is a function of other test conditions. A steady, constant acceleration may result in an increase or decrease of the operating temperature, while a periodic spin will lead to a quasi-steady operating temperature over a sufficient time interval. In addition, an accelerating force may lead to temperature hysteresis and changes in the temperature oscillation. In spite of all these effects, the LHP continued to operate without any problems in all tests.
Closure plan for Corrective Action Unit 109: U-2bu subsidence crater, Nevada Test Site, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
The U-2bu subsidence crater, Corrective Action Unit 109, will be closed in accordance with the Resource Conservation and Recovery Act, the Nevada Division of Environmental Protection operational permit, and the Federal Facility Agreement and Consent Order. The U-2bu subsidence crater is located in Area 2 of the Nevada Test Site. It was created in 1971 by an underground nuclear test with the name Miniata. The crater has a diameter of 288 meters (944 feet) and an approximate depth of 35 meters (115 feet). Based on the results of the analyses reported in the site characterization report, the only constituents ofmore » concern in the U-2bu subsidence crater include leachable lead and total petroleum hydrocarbons. Closure activities will include the excavation and disposal of impacted soil from the top of the crater. Upon completion of excavation, verification samples will be collected to show that the leachable lead has been removed to concentrations below the regulatory action level. After sample results show that the lead has been removed, the excavated area will be backfilled and a soil flood diversion berm will be constructed as a best management practice. An independent registered professional engineer will certify the site was closed following the approved Closure Plan. Post-closure care is not warranted for this site because closure activities will involve removal of the Resource Conservation and Recovery Act constituents of concern.« less
Prechamber equipped laser ignition for improved performance in natural gas engines
Almansour, Bader; Vasu, Subith; Gupta, Sreenath B.; ...
2017-04-25
Lean-burn operation of stationary natural gas engines offers lower NO x emissions and improved efficiency. A proven pathway to extend lean-burn operation has been to use laser ignition instead of standard spark ignition. However, under lean conditions, flame speed reduces thereby offsetting any efficiency gains resulting from the higher ratio of specific heats, γ. The reduced flame speeds, in turn, can be compensated with the use of a prechamber to result in volumetric ignition, and thereby lead to faster combustion. In this study, the optimal geometry of PCLI was identified through several tests in a single-cylinder engine as a compromisemore » between autoignition, NO x and soot formation within the prechamber. Subsequently, tests were conducted in a single-cylinder natural gas engine comparing the performance of three ignition systems: standard electrical spark ignition (SI), single-point laser ignition (LI), and prechamber equipped laser ignition (PCLI). Out of the three, the performance of PCLI was far superior compared to the other two. Efficiency gain of 2.1% points could be achieved while complying with EPA regulation (BSNO x < 1.34 kW-hr) and the industry standard for ignition stability (COV_IMEP < 5%). Finally, test results and data analysis are presented identifying the combustion mechanisms leading to the improved performance.« less
Code of Federal Regulations, 2011 CFR
2011-10-01
... Corrosion Control § 195.567 Which pipelines must have test leads and what must I do to install and maintain... corrosion control. However, this requirement does not apply until December 27, 2004 to pipelines or pipeline...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Corrosion Control § 195.567 Which pipelines must have test leads and what must I do to install and maintain... corrosion control. However, this requirement does not apply until December 27, 2004 to pipelines or pipeline...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Corrosion Control § 195.567 Which pipelines must have test leads and what must I do to install and maintain... corrosion control. However, this requirement does not apply until December 27, 2004 to pipelines or pipeline...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Corrosion Control § 195.567 Which pipelines must have test leads and what must I do to install and maintain... corrosion control. However, this requirement does not apply until December 27, 2004 to pipelines or pipeline...
Analysis of Slug Test Response in a Fracture of a Large Dipping Angle
NASA Astrophysics Data System (ADS)
Chen, C.
2013-12-01
A number of cross-borehole slug tests were conducted in a Cenozoic folded sandstone formation, where a fracture has a dipping angle as large as 47°. As all the slug test models available in literature assume the formation to be horizontal, a slug test model taking into account the dipping angle effect is developed herein. Due to the presence of the dipping angle, there is a uniform regional groundwater flow, and the flow field generated by the test is not raidally symmetrical with respect to the test well. When the fracture hydraulic conductivity is relatively low, a larger dipping angle causes larger wellbore flow rates, leading to a faster recovery of the non-oscillatory test response. When the fracture hydraulic conductivity is relatively high, a larger dipping angle causes smaller wellbore heads, resulting in an increase of amplitude of the oscillatory test response; yet little influence on the frequency of oscillation. In general, neglecting the dipping angle may lead to an overestimate of hydraulic conductivity and an underestimate of the storage coefficient. The dipping angle effect is more pronounced for a larger storage coefficient, being less sensitive to transmissivity. An empirical relationship is developed for the minimum dipping angle, smaller than which the dipping angle effect can be safely neglected, as a function of the dimensionless storage coefficient. This empirical relationship helps evaluate whether or not the dipping angle needs to be considered in data analysis. The slug test data in the fracture of a 47°dipping angle is analyzed using the current model, and it is found that neglecting the dip angle can result in a 30% overestimate of transmissivity and a 61% underestimate of the storage coefficient.
Positive perception of pharmacogenetic testing for psychotropic medications
Lanktree, Matthew B; Zai, Gwyneth; VanderBeek, Laura E; Giuffra, Daniel E; Smithson, David S; Kipp, Lucas B; Dalseg, Timothy R; Speechley, Mark; Kennedy, James L
2014-01-01
Introduction Pharmacogenetics attempts to identify inter-individual genetic differences that are predictive of variable drug response and propensity to side effects, with the prospect of assisting physicians to select the most appropriate drug and dosage for treatment. However, many concerns regarding genetic tests exist. We sought to test the opinions of undergraduate science and medical students in southern Ontario universities toward pharmacogenetic testing. Methods and Results Questionnaires were completed by 910 undergraduate medicine and science students from 2005 to 2007. Despite students' concerns that the results of genetic tests may be used for other purposes without consent (71%) or lead to discrimination (78%), an overwhelming number of students were in favor of pharmacogenetic testing (90%). Discussion To our knowledge, this study is the first to survey a large sample for their attitude toward pharmacogenetic testing for psychotropic medications. Our results indicate that, although concerns remain and scientific advancements are required, respondents were in support of pharmacogenetic testing for medications used to treat schizophrenia. © 2014 The Authors. Human Psychopharmacology: Clinical and Experimental published by John Wiley & Sons, Ltd. PMID:24604560
Aerodynamic and acoustic test of a United Technologies model scale rotor at DNW
NASA Technical Reports Server (NTRS)
Yu, Yung H.; Liu, Sandy R.; Jordan, Dave E.; Landgrebe, Anton J.; Lorber, Peter F.; Pollack, Michael J.; Martin, Ruth M.
1990-01-01
The UTC model scale rotors, the DNW wind tunnel, the AFDD rotary wing test stand, the UTRC and AFDD aerodynamic and acoustic data acquisition systems, and the scope of test matrices are discussed and an introduction to the test results is provided. It is pointed out that a comprehensive aero/acoustic database of several configurations of the UTC scaled model rotor has been created. The data is expected to improve understanding of rotor aerodynamics, acoustics, and dynamics, and lead to enhanced analytical methodology and design capabilities for the next generation of rotorcraft.
In Situ Optical Creep Observation of Joint-Scale Tin-Silver-Copper Solder Shear Samples
NASA Astrophysics Data System (ADS)
Herkommer, Dominik; Reid, Michael; Punch, Jeff
2009-10-01
In this paper the creep behavior of lead-free 96.5Sn-3.0Ag-0.5Cu solder is evaluated. A series of creep tests at different stress/temperature and strain rate/temperature pairs has been conducted. The tests were observed in situ with a high-magnification camera system. Optical observation results are presented from selected tests, showing the occurrence of surface effects such as shear bands, voiding, and rumpling. From these observations the main deformation mechanisms were derived and compiled in terms of their dependence on the test conditions.
Studies of lead tungstate crystals for the ALICE electromagnetic calorimeter PHOS
NASA Astrophysics Data System (ADS)
Ippolitov, M.; Beloglovsky, S.; Bogolubsky, M.; Burachas, S.; Erin, S.; Klovning, A.; Kuriakin, A.; Lebedev, V.; Lobanov, M.; Maeland, O.; Manko, V.; Nikulin, S.; Nyanin, A.; Odland, O. H.; Punin, V.; Sadovsky, S.; Samoilenko, V.; Sibiriak, Yu.; Skaali, B.; Tsvetkov, A.; Vinogradov, Yu.; Vasiliev, A.
2002-06-01
Full-size (22×22×180 mm 3) A LICE crystals were delivered by "North Crystals" company, Apatity, Russia. These crystals were tested with test benches, specially built for measurements of the crystals optical transmission and light yield. Beam-test results of different sets of 3×3 matrices with Hamamatsu APD light readout are presented. Data were taken at electron momenta from 600 MeV/ c up to 10 GeV/ c. Energy resolution and linearity curves are measured. The tests were carried out at the C ERN PS and SPS secondary beam-lines.
Greenway, Joseph A; Gerstenberger, Shawn
2010-10-01
Childhood exposure to environmental lead continues to be a major health concern. This study examined lead content within the plastic of children's toys collected from licensed day care centers in the Las Vegas valley, Nevada. It was hypothesized that the use of lead as a plastics stabilizer would result in elevated lead (≥600 ppm) in polyvinyl chloride plastics (PVC) compared to non-PVC plastics. It was also hypothesized that, due to the use of lead chromate as a coloring agent, yellow toys would contain higher concentrations of lead (≥600 ppm) than toys of other colors. Toy samples were limited to those found in day care centers in Las Vegas, Nevada. 10 day care centers were visited and approximately 50 toy samples were taken from each center. Of the 535 toys tested, 29 contained lead in excess of 600 parts per million (ppm). Of those 29 toys, 20 were PVC and 17 were yellow. Both of the two hypotheses were strongly supported by the data.
The effect of butterfly scales on flight efficiency and leading edge vortex formation
NASA Astrophysics Data System (ADS)
Lang, Amy; Wilroy, Jacob; Wahidi, Redha; Slegers, Nathan; Heilman, Micahel; Cranford, Jacob
2016-11-01
It is hypothesized that the scales on a butterfly wing lead to increased flight efficiency. Recent testing of live butterflies tracked their motion over 246 flights for 11 different specimens. Results show a 37.8 percent mean decrease in flight efficiency and a flapping amplitude reduction of 6.7 percent once the scales were removed. This change could be largely a result of how the leading edge vortex (LEV) interacts with the wing. To simplify this complex flow problem, an experiment was designed to focus on the alteration of 2-D vortex development with a variation in surface patterning. Specifically, the secondary vorticity generated by the LEV interacting at the patterned surface was studied, as well as the subsequent effect on the LEV's growth rate and peak circulation. For this experiment butterfly inspired grooves were created using additive manufacturing and were attached to a flat plate with a chordwise orientation, thus increasing plate surface area. The vortex generated by the grooved plate was then compared to a smooth case as the plate translated vertically through a tow tank at Re = 1500, 3000, and 6000. Using DPIV, the vortex formation was documented and a maximum vortex formation time of 4.22 was found based on the flat plate travel distance and chord length. Results indicate that the patterned surface slows down the growth of the vortex which corroborates the flight test results. Funding from NSF CBET Fluid Dynamcis is gratefully acknowledged.
Compound scale-up at the discovery-development interface.
Nikitenko, Antonia A
2006-11-01
As a result of an economically challenging environment within the pharmaceutical industry, pharmaceutical companies and their departments must increase productivity and cut costs to stay in line with the market. Discovery-led departments such as the medicinal chemistry and lead optimization groups focus on synthesizing large varieties of compounds in minimal amounts, while the chemical development groups must then deliver a few chosen leads employing an optimized synthesis method and using multi-kilogram quantities of material. A research group at the discovery-development interface has the task of medium-scale synthesis which is important in the lead selection stage. The primary objective of this group is the initial scale-up of promising leads for extensive physicochemical and biological testing. The challenge of the interface group involves overcoming synthetic issues within the rigid, accelerated timelines.
Leading-edge vortex lifts swifts.
Videler, J J; Stamhuis, E J; Povel, G D E
2004-12-10
The current understanding of how birds fly must be revised, because birds use their hand-wings in an unconventional way to generate lift and drag. Physical models of a common swift wing in gliding posture with a 60 degrees sweep of the sharp hand-wing leading edge were tested in a water tunnel. Interactions with the flow were measured quantitatively with digital particle image velocimetry at Reynolds numbers realistic for the gliding flight of a swift between 3750 and 37,500. The results show that gliding swifts can generate stable leading-edge vortices at small (5 degrees to 10 degrees) angles of attack. We suggest that the flow around the arm-wings of most birds can remain conventionally attached, whereas the swept-back hand-wings generate lift with leading-edge vortices.
Development of chip passivated monolithic complementary MISFET circuits with beam leads
NASA Technical Reports Server (NTRS)
Ragonese, L. J.; Kim, M. J.; Corrie, B. L.; Brouillette, J. W.; Warr, R. E.
1972-01-01
The results are presented of a program to demonstrate the processes for fabricating complementary MISFET beam-leaded circuits, which, potentially, are comparable in quality to available bipolar beam-lead chips that use silicon nitride passivation in conjunction with a platinum-titanium-gold metal system. Materials and techniques, different from the bipolar case, were used in order to be more compatible with the special requirements of fully passivated complementary MISFET devices. Two types of circuits were designed and fabricated, a D-flip-flop and a three-input NOR/NAND gate. Fifty beam-leaded chips of each type were constructed. A quality and reliability assurance program was performed to identify failure mechanisms. Sample tests and inspections (including destructive) were developed to measure the physical characteristics of the circuits.
NASA Technical Reports Server (NTRS)
McMillin, Summer D.; Broerman, Craig D.; Swickrath, Michael; Anderson, Molly
2011-01-01
A principal concern for extravehicular activity (EVA) spacesuits is the capability to control carbon dioxide (CO2) and humidity (H2O) for the crewmember. The release of CO2 in a confined or unventilated area is dangerous for human health and leads to asphyxiation; therefore, CO2 and H2O control become leading factors in the design and development of the spacesuit. An amine-based CO2 and H2O vapor sorbent for use in pressure-swing regenerable beds has been developed by Hamilton Sundstrand. The application of solidamine materials with vacuum swing adsorption technology has shown the capacity to concurrently manage CO2 and H2O levels through a fully regenerative cycle eliminating mission constraints imposed with nonregenerative technologies. Two prototype solid amine-based systems, known as rapid cycle amine (RCA), were designed to continuously remove CO2 and H2O vapor from a flowing ventilation stream through the use of a two-bed amine based, vacuum-swing adsorption system. The Engineering and Science Contract Group (ESCG) RCA implements radial flow paths, whereas the Hamilton Sundstrand RCA was designed with linear flow paths. Testing was performed in a sea-level pressure environment and a reduced-pressure environment with simulated human metabolic loads in a closed-loop configuration. This paper presents the experimental results of laboratory testing for a full-size and a sub-scale test article. The testing described here characterized and evaluated the performance of each RCA unit at the required Portable Life Support Subsystem (PLSS) operating conditions. The test points simulated a range of crewmember metabolic rates. The experimental results demonstrated the ability of each RCA unit to sufficiently remove CO2 and H2O from a closed loop ambient or sub-ambient atmosphere.
Whisker dependent responsiveness of C57BL/6J mice to different behavioral test paradigms.
Haridas, Seenu; Ganapathi, Ramya; Kumar, Mayank; Manda, Kailash
2018-01-15
Whisker trimming is very common in C57BL/6J mice. Dewhiskering may lead to an alteration in the thalamocortical connectivity and relevant behavioral functions. Since C57BL/6J is a commonly used strain for neurobehavioral studies, it is important to examine how whisker dependent heterogeneity affects the internal validity of behavioral phenotypes. The present study aimed to investigate the responsiveness of mice to different behavioral test paradigms in the presence or absence of whiskers. We employed two models of whisker deprivation: Acute Whisker Desensitization (AWD) and Chronic Habitual Dewhiskering (CHD). The AWD model blocks whisker sensation by lidocaine application. For CHD model, mice at the age of 12 weeks were carefully scrutinized for presence or absence of whiskers and divided into three groups, the whiskered mice, partially dewhiskered mice and completely dewhiskered mice. The whisker-dependent behavioral functions were assessed using open field test, novel object recognition test, marble burying test and forced swim test. Our results showed that habitual dewhiskering significantly altered the short-term memory and basal anxiety-like functions. Such behavioral alteration due to dewhiskering was significantly different in fully and partially dewhiskered mice, which is indicative of behavioral adaptation to the whisker desensitization. Contrary to CHD, the Acute Whisker Desensitization ameliorated behavioral compulsivity and basal anxiety. Our results suggest that vibrissal desensitization in the mice may lead to changes in their affective and cognitive state. Since, heterogeneity in whisker status may affect behavioral functions, careful inspection of the whisker status of C57BL/6J mice is recommended to increase the reproducibility and reliability of results obtained from behavioral assessments. Copyright © 2017 Elsevier B.V. All rights reserved.
Effect of vitamin E on lead exposure-induced learning and memory impairment in rats.
Khodamoradi, Nasrin; Komaki, Alireza; Salehi, Iraj; Shahidi, Siamak; Sarihi, Abdolrahman
2015-05-15
Chronic lead (Pb(2+)) exposure has been associated with learning and memory impairments, whereas vitamin E improves cognitive deficits. In this study, using a passive avoidance learning model in rats, we investigated the effects of vitamin E on Pb(2+) exposure-induced learning and memory impairments in rats. In the present study, 56 Wistar male rats (weighting 230-250g) were divided into eight groups (n=7). The Pb(2+) exposure involved gavages of lead acetate solution using three different doses (0.05%, 0.1%, and 0.2%) and the vitamin E consisted of three different doses (10, 25, 50μg/rat) for 30days. After the 30-day period, the rats were tested using a passive avoidance task (acquisition test). In a retrieval test conducted 48h after the training, step through latency (STL) and time in the dark compartment (TDC) were recorded. The statistical analysis of data was performed using ANOVA followed by Tukey's post hoc analysis. In all cases, differences were considered significant if p<0.05. The results of the present study showed that chronic exposure to high doses of Pb(2+) significantly increased both the number of trails required for learning and the TDC, whereas it decreased the STL in the passive avoidance test. Administration of vitamin E ameliorated the effects of Pb(2+) on animal behavior in the passive avoidance learning and memory task. Our results indicate that impairments of learning and memory in Pb(2+)-exposed rats are dose dependent and can be inhibited by antioxidants such as vitamin E. Copyright © 2015 Elsevier Inc. All rights reserved.
Ebau, Warrin; Rawi, Che Salmah Md; Din, Zubir; Al-Shami, Salman Abdo
2012-01-01
Objective To investigate the acute toxicity of cadmium and lead on larvae of two tropical Chironomid species, Chironomus kiiensis (C. kiiensis) Tokunaga and Chironomus javanus (C. javanus) Kieffer. Methods Different larval instars (first-fourth) were exposed using a static non-replacement testing procedures to various concentrations of cadmium and lead. Results In general, younger larvae (first and second instars) of both species were more sensitive to both metals than older larvae (third and forth instars). The toxic effects of the metals on C. kiiensis and C. javanus were influenced by the age of the larvae (first to fourth instars), types of metals (cadmium or lead) and duration of larval exposure (24, 48, 72 and 96 h) to the metals. Conclusions Cadmium was more toxic to the chironomids than lead and C. javanus was significantly more sensitive to both metals than C. kiiensis (P<0.05). PMID:23569984
Adamczyk, L.
2015-10-23
The STAR Collaboration presents for the first time two-dimensional di-hadron correlations with identified leading hadrons in 200 GeV central Au + Au and minimum-bias d + Au collisions to explore hadronization mechanisms in the quark gluon plasma. The enhancement of the jet-like yield for leading pions in Au + Au data with respect to the d + Au reference and the absence of such an enhancement for leading non-pions (protons and kaons) are discussed within the context of a quark recombination scenario. The correlated yield at large angles, specifically in the ridge region, is found to be significantly higher formore » leading non-pions than pions. As a result, the consistencies of the constituent quark scaling, azimuthal harmonic model and a mini-jet modification model description of the data are tested, providing further constraints on hadronization.« less
Biological monitoring of glazers exposed to lead in the ceramics industry in Iran.
Shouroki, Fatemeh Kargar; Shahtaheri, Seyed Jamaleddin; Golbabaei, Farideh; Barkhordari, Abolfazle; Rahimi-Froushani, Abbas
2015-01-01
Exposure to heavy metals, particularly lead, takes place in the ceramics industry. Lead is used in glaze to produce smooth and brilliant surfaces; thus, there is a likelihood of occupational adverse effects on humans. Urine samples were collected from 49 glazers at the start and end of the work shifts (98 samples). Solid phase extraction was used for separation and pre-concentration of the analyte. Samples were analysed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Lung function tests were performed on both control and lead exposed subjects. Statistical analysis of covariance (ANCOVA) was used to evaluate the data obtained. The concentration of lead in glazers was 6.37 times higher than in the control group. Lung functions were significantly lower in the glazers compared to the control group (p < 0.001). Results showed that poor ventilation systems, overtime work and work history are effective determinants of high exposure levels.
Shock Interaction Control for Scramjet Cowl Leading Edges
NASA Technical Reports Server (NTRS)
Albertson, Cindy W.; Venkat, Venki, S.
2005-01-01
An experimental study was conducted to qualitatively determine the effectiveness of stagnation-region gas injection in protecting a scramjet cowl leading edge from the intense heating produced by Type III and Type IV shock interactions. The model consisted of a two-dimensional leading edge, representative of that of a scramjet cowl. Tests were conducted at a nominal freestream Mach number of 6. Gaseous nitrogen was supersonically injected through the leading-edge nozzles at various mass flux ratios and with the model pitched at angles of 0deg and -20deg relative to the freestream flow. Qualitative data, in the form of focusing and conventional schlieren images, were obtained of the shock interaction patterns. Results indicate that large shock displacements can be achieved and both the Type III and IV interactions can be altered such that the interaction does not impinge on the leading edge surface.
2014-01-01
Background Dengue is an acute arboviral disease responsible for most of the illness and death in tropical and subtropical regions. Over the last 25 years there has been increase epidemic activity of the disease in the Caribbean, with the co-circulation of multiple serotypes. An understanding of the space and time dynamics of dengue could provide health agencies with important clues for reducing its impact. Methods Dengue Haemorrhagic Fever (DHF) cases observed for the period 1998–2004 were georeferenced using Geographic Information System software. Spatial clustering was calculated for individual years and for the entire study period using the Nearest Neighbor Index. Space and time interaction between DHF cases was determined using the Knox Test while the Nearest Neighbor Hierarchical method was used to extract DHF hot spots. All space and time distances calculated were validated using the Pearson r significance test. Results Results shows that (1) a decrease in mean distance between DHF cases correlates with activity leading up to an outbreak, (2) a decrease in temporal distance between DHF cases leads to increased geographic spread of the disease, with an outbreak occurrence about every 2 years, and (3) a general pattern in the movement of dengue incidents from more rural to urban settings leading up to an outbreak with hotspot areas associated with transportation hubs in Trinidad. Conclusion Considering only the spatial dimension of the disease, results suggest that DHF cases become more concentrated leading up to an outbreak. However, with the additional consideration of time, results suggest that when an outbreak occurs incidents occur more rapidly in time leading to a parallel increase in the rate of distribution of the disease across space. The results of this study can be used by public health officers to help visualize and understand the spatial and temporal patterns of dengue, and to prepare warnings for the public. Dengue space-time patterns and hotspot detection will provide useful information to support public health officers in their efforts to control and predict dengue spread over critical hotspots allowing better allocation of resources. PMID:25052242
Mass lead intoxication from informal used lead-acid battery recycling in dakar, senegal.
Haefliger, Pascal; Mathieu-Nolf, Monique; Lociciro, Stephanie; Ndiaye, Cheikh; Coly, Malang; Diouf, Amadou; Faye, Absa Lam; Sow, Aminata; Tempowski, Joanna; Pronczuk, Jenny; Filipe Junior, Antonio Pedro; Bertollini, Roberto; Neira, Maria
2009-10-01
Between November 2007 and March 2008, 18 children died from a rapidly progressive central nervous system disease of unexplained origin in a community involved in the recycling of used lead-acid batteries (ULAB) in the suburbs of Dakar, Senegal. We investigated the cause of these deaths. Because autopsies were not possible, the investigation centered on clinical and laboratory assessments performed on 32 siblings of deceased children and 23 mothers and on 18 children and 8 adults living in the same area, complemented by environmental health investigations. All 81 individuals investigated were poisoned with lead, some of them severely. The blood lead level of the 50 children tested ranged from 39.8 to 613.9 microg/dL with a mean of 129.5 microg/dL. Seventeen children showed severe neurologic features of toxicity. Homes and soil in surrounding areas were heavily contaminated with lead (indoors, up to 14,000 mg/kg; outdoors, up to 302,000 mg/kg) as a result of informal ULAB recycling. Our investigations revealed a mass lead intoxication that occurred through inhalation and ingestion of soil and dust heavily contaminated with lead as a result of informal and unsafe ULAB recycling. Circumstantial evidence suggested that most or all of the 18 deaths were due to encephalopathy resulting from severe lead intoxication. Findings also suggest that most habitants of the contaminated area, estimated at 950, are also likely to be poisoned. This highlights the severe health risks posed by informal ULAB recycling, in particular in developing countries, and emphasizes the need to strengthen national and international efforts to address this global public health problem.
Attitudes of Mothers of Children with Down Syndrome Towards Noninvasive Prenatal Testing
Kellogg, Gregory; Slattery, Leah; Hudgins, Louanne; Ormond, Kelly
2014-01-01
Noninvasive prenatal testing (NIPT) allows for highly sensitive detection of Down syndrome early in pregnancy with no risk of miscarriage, therefore potentially increasing the number of pregnancies identified with Down syndrome. This study assesses how mothers of children with Down syndrome perceive NIPT, especially the impact they think it will have on their families and other families with children who have Down syndrome. Seventy-three self-reported mothers of children with Down syndrome responded to an anonymous online survey emailed to, and posted on, message boards of various Down syndrome support groups and networks. Data analysis included chi-square tests and thematic analysis. Fifty-nine percent of respondents indicated they would use NIPT in the future; respondents who had not used prenatal testing in the past were significantly less likely to report interest in using NIPT in the future than those who had prenatal testing previously (p<.001). Many respondents felt NIPT could lead to increased terminations (88%), increased social stigma (57%), and decreased availability of services for individuals with Down syndrome (64%). However, only 16% believed availability of new noninvasive tests would be the most important factor in determining the number of pregnancies with Down syndrome terminated in the future. Additionally, 48% believed health care providers give biased or incorrect information about Down syndrome at the time of diagnosis, and 24% felt this incorrect information leads to terminations of pregnancies affected with Down syndrome. Results suggest although mothers of children with Down syndrome believe new noninvasive testing will lead to an increase in termination of pregnancies with Down syndrome, they do not think it is the MOST important factor. They also highlight the need to provide a diagnosis of Down syndrome in a balanced and objective manner. PMID:24481673
NASA Technical Reports Server (NTRS)
Buttery, Michael
2010-01-01
We present the findings of the test program performed by The European Space Tribology Laboratory (ESTL) to evaluate the performance (friction and lifetime) of a number of space lubricants under vacuum using a Spiral Orbit Tribometer (SOT). Focus was given to a comparison of various popular space oils, a comparison study between the old and new MAPLUB grease formulations, and the performance of commonly used solid lubricants under various conditions. Tests demonstrated that the lifetimes of hydrocarbon NYE oils 2001 & 2001A outperformed those of the perfluroropolyalkylether (PFPE) oils Fomblin Z25 & Z60, though these pairs displayed similar behavior. This relationship was also generally seen for greases; with the lifetimes of the multiple alkylated cyclopentane (MAC)-based greases being extended in comparison to the PFPE-based greases. Testing on greases also demonstrated similar performance between the old (-a) and new (-b) formulations when considering PFPE-based MAPLUB greases, and indeed for all tested PFPE-based non-MAPLUB greases, but significantly shorter lifetimes for the new formulations when considering MAC-based MAPLUB greases. MAPLUB MAC greases containing molybdenum disulphide (MoS2) thickener were also found to display reduced lifetimes. For solid lubricants, lead displayed significantly extended lifetimes over MoS2, speculated to be caused by redistribution of lead from the ball onto all contact surfaces during the test. Friction coefficients were seen to be some 2.5x higher for lead than for MoS2 under similar conditions, a result that corresponds well with conventional bearing tests. The work described was performed under contract for the European Space Agency as part of the Tribology Applications Program, with all funding for testing and apparatus provided by European Space Agency (ESA).