Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.
2015-01-01
An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware
NASA Technical Reports Server (NTRS)
Oravec, Heather Ann; Daniels, Christopher C.; Mather, Janice L.
2017-01-01
As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 kPa. Up to six combinations of upstream and downstream pressures for each differential pressure were compared. For a given differential pressure, the various combinations of upstream and downstream dry air pressures did not significantly affect the leak rate. As expected, the leak rate of the O-ring increased with increasing differential pressure. The results suggested that the current leak test pressure conditions, used to verify spacecraft sealing systems with elastomer seals, produce accurate values even though the boundary conditions do not model the space application.
Patel, Jayshree; Mulhall, Brian; Wolf, Heinz; Klohr, Steven; Guazzo, Dana Morton
2011-01-01
A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated for container-closure integrity verification of a lyophilized product in a parenteral vial package system. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Method development and optimization challenge studies incorporated artificially defective packages representing a range of glass vial wall and sealing surface defects, as well as various elastomeric stopper defects. Method validation required 3 days of random-order replicate testing of a test sample population of negative-control, no-defect packages and positive-control, with-defect packages. Positive-control packages were prepared using vials each with a single hole laser-drilled through the glass vial wall. Hole creation and hole size certification was performed by Lenox Laser. Validation study results successfully demonstrated the vacuum decay leak test method's ability to accurately and reliably detect those packages with laser-drilled holes greater than or equal to approximately 5 μm in nominal diameter. All development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work. A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated to detect defects in stoppered vial packages containing lyophilized product for injection. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Test method validation study results proved the method capable of detecting holes laser-drilled through the glass vial wall greater than or equal to 5 μm in nominal diameter. Total test time is less than 1 min per package. All method development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work.
Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Godorov, Phillip; Guazzo, Dana Morton
2009-01-01
ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method is applicable for leak-testing rigid and semi-rigid non-lidded trays; trays or cups sealed with porous barrier lidding materials; rigid, nonporous packages; and flexible, nonporous packages. Part 1 of this series describes the precision and bias studies performed in 2008 to expand this method's scope to include rigid, nonporous packages completely or partially filled with liquid. Round robin tests using three VeriPac 325/LV vacuum decay leak testers (Packaging Technologies & Inspection, LLC, Tuckahoe, NY) were performed at three test sites. Test packages were 1-mL glass syringes. Positive controls had laser-drilled holes in the barrel ranging from about 5 to 15 microm in nominal diameter. Two different leak tests methods were performed at each site: a "gas leak test" performed at 250 mbar (absolute) and a "liquid leak test" performed at about 1 mbar (absolute). The gas leak test was used to test empty, air-filled syringes. All defects with holes > or = 5.0 microm and all no-defect controls were correctly identified. The only false negative result was attributed to a single syringe with a < 5.0-microm hole. Tests performed using a calibrated air leak supported a 0.10-cm3 x min(-1) (ccm) sensitivity limit (99/99 lower tolerance limit). The liquid leak test was used to test both empty, air-filled syringes and water-filled syringes. Test results were 100% accurate for all empty and water-filled syringes, both without holes and with holes (5, 10, and 15 microm). Tests performed using calibrated air flow leaks of 0, 0.05, and 0.10 ccm were also 100% accurate; data supported a 0.10-ccm sensitivity limit (99/99 lower tolerance limit). Quantitative differential pressure results strongly correlated to hole size using either liquid or gas vacuum decay leak tests. The higher vacuum liquid leak test gave noticeably higher pressure readings when water was present in the defect. Both the ASTM F2338-09 test method and the precision and bias study report are available by contacting ASTM International in West Conshohocken, PA, USA (www.astm.org).
Aerospace Payloads Leak Test Methodology
NASA Technical Reports Server (NTRS)
Lvovsky, Oleg; Grayson, Cynthia M.
2010-01-01
Pressurized and sealed aerospace payloads can leak on orbit. When dealing with toxic or hazardous materials, requirements for fluid and gas leakage rates have to be properly established, and most importantly, reliably verified using the best Nondestructive Test (NDT) method available. Such verification can be implemented through application of various leak test methods that will be the subject of this paper, with a purpose to show what approach to payload leakage rate requirement verification is taken by the National Aeronautics and Space Administration (NASA). The scope of this paper will be mostly a detailed description of 14 leak test methods recommended.
Sudo, Hirotaka; O'driscoll, Michael; Nishiwaki, Kenji; Kawamoto, Yuji; Gammell, Philip; Schramm, Gerhard; Wertli, Toni; Prinz, Heino; Mori, Atsuhide; Sako, Kazuhiro
2012-01-01
The application of a head space analyzer for oxygen concentration was examined to develop a novel ampoule leak test method. Studies using ampoules filled with ethanol-based solution and with nitrogen in the headspace demonstrated that the head space analysis (HSA) method showed sufficient sensitivity in detecting an ampoule crack. The proposed method is the use of HSA in conjunction with the pretreatment of an overpressurising process known as bombing to facilitate the oxygen flow through the crack in the ampoule. The method was examined in comparative studies with a conventional dye ingress method, and the results showed that the HSA method exhibits sensitivity superior to the dye method. The results indicate that the HSA method in combination with the bombing treatment provides potential application as a leak test for the detection of container defects not only for ampoule products with ethanol-based solutions, but also for testing lyophilized products in vials with nitrogen in the head space. The application of a head space analyzer for oxygen concentration was examined to develop a novel ampoule leak test method. The proposed method is the use of head space analysis (HSA) in conjunction with the pretreatment of an overpressurising process known as bombing to facilitate oxygen flow through the crack in the ampoule for use in routine production. The result of the comparative study with a conventional dye leak test method indicates that the HSA method in combination with the bombing treatment can be used as a leak test method, enabling detection of container defects.
Code of Federal Regulations, 2010 CFR
2010-04-01
... examination and by a water leak test method, using 1,000 milliliters (ml) of water. (i) Units examined. Each... inches up the fill tube.) (iii) Leak test examination. Immediately after adding the water, examine the glove for water leaks. Do not squeeze the glove; use only minimum manipulation to spread the fingers to...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2014 CFR
2014-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2013 CFR
2013-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2012 CFR
2012-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
Sensitivities of Soap Solutions in Leak Detection
NASA Technical Reports Server (NTRS)
Stuck, D.; Lam, D. Q.; Daniels, C.
1985-01-01
Document describes method for determining minimum leak rate to which soap-solution leak detectors sensitive. Bubbles formed at smaller leak rates than previously assumed. In addition to presenting test results, document discusses effects of joint-flange configurations, properties of soap solutions, and correlation of test results with earlier data.
Verification of International Space Station Component Leak Rates by Helium Accumulation Method
NASA Technical Reports Server (NTRS)
Underwood, Steve D.; Smith, Sherry L.
2003-01-01
Discovery of leakage on several International Space Station U.S. Laboratory Module ammonia system quick disconnects (QDs) led to the need for a process to quantify total leakage without removing the QDs from the system. An innovative solution was proposed allowing quantitative leak rate measurement at ambient external pressure without QD removal. The method utilizes a helium mass spectrometer configured in the detector probe mode to determine helium leak rates inside a containment hood installed on the test component. The method was validated through extensive developmental testing. Test results showed the method was viable, accurate and repeatable for a wide range of leak rates. The accumulation method has been accepted by NASA and is currently being used by Boeing Huntsville, Boeing Kennedy Space Center and Boeing Johnson Space Center to test welds and valves and will be used by Alenia to test the Cupola. The method has been used in place of more expensive vacuum chamber testing which requires removing the test component from the system.
Locating air leaks in manned spacecraft using structure-borne noise.
Holland, Stephen D; Chimenti, D E; Roberts, Ron; Strei, Michael
2007-06-01
All manned spacecraft are vulnerable to leaks generated by micrometeorite or debris impacts. Methods for locating such leaks using leak-generated, structure-borne ultrasonic noise are discussed and demonstrated. Cross-correlations of ultrasonic noise waveforms from a leak into vacuum are used to find the location of the leak. Four methods for sensing and processing leak noise have been developed and tested and each of these can be used to reveal the leak location. The methods, based on phased-array, distributed sensor, and dual sensor approaches, utilize the propagation patterns of guided ultrasonic Lamb waves in the spacecraft skin structure to find the source or direction of the leak noise. It is shown that each method can be used to successfully locate the leak to within a few millimeters on a 0.6-m2 aluminum plate. The relative merits of the four methods are discussed.
White gauze test: a novel technique in preventing post-hepatectomy bile leak.
Yugasaravanan, K; Affirul, C A; Zamri, Z; Azlanudin, A; Bong, J J
Post-hepatectomy bile leak may lead to undesired morbidity. Multiple methods have been employed to identify this leak but can be inconclusive and taxing. This novel white gauze test is a simple and reliable method. This is a prospective study performed from January 2010 until March 2011. All open hepatic resection were included. Dry white gauze is compressed onto the transected surface and observed for bile staining. The leaking duct is repaired immediately upon detection. The process is repeated until negative. Drain was removed on postoperative day-5. Post-operative bile leak is defined as: 1. Bilirubin concentration of the drain fluid is 3 times or higher than serum; 2. Presence of intra-abdominal bile collection on imaging and upon drainage; 3. Bile leak demonstrated on postoperative cholangiography. 42 patients were recruited. Seven (16.7%) patients were cirrhotic with Child-Pugh A. White gauze test were positive for intra-operative bile leaks in 29 patients (70%), which were primarily repaired. As a result, there was no postoperative bile leak in this series. One mortality was detected in this series due to postoperative pancreatic fistula and multi organ failure. The White Gauze Test is a useful method for the prevention of bile leakage after hepatic resection. It is safe, quick and cheap.
Nieto, Alejandra; Roehl, Holger; Brown, Helen; Adler, Michael; Chalus, Pascal; Mahler, Hanns-Christian
2016-01-01
Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against possible contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow (helium leakage testing). In order to correlate microbial CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificial leaks are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. However, the insertion of copper wires introduces leaks of unknown size and shape. With nonlinear finite element simulations, the aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force. The dependency of the aperture size on the copper wire diameter was quadratic. With the data obtained, we were able to calculate the leak size and model leak shape. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to hole size. Capping force also affected leak size. An increase in the capping force from 30 to 70 N resulted in a reduction of the aperture (leak size) by approximately 50% for all wire diameters. From 30 to 50 N, the reduction was approximately 33%. Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow. In order to correlate microbial ingress CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificially created defects (artificial leaks) are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. Up to date, the insertion of copper wires introduced leaks of unknown size and shape. With nonlinear finite element simulations, the effective aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force, and the leak shape was modelled. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to the hole size. © PDA, Inc. 2016.
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Detection of leaking sources. 36.59 Section 36.59 Energy... Irradiators § 36.59 Detection of leaking sources. (a) Each dry-source-storage sealed source must be tested for leakage at intervals not to exceed 6 months using a leak test kit or method approved by the Commission or...
40 CFR 63.11094 - What are my recordkeeping requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
...: Test pressure; pressure or vacuum change, mm of water; time period of test; number of leaks found with... § 63.11092(f)(1) and periodic railcar bubble leak testing performed under § 63.11092(f)(2). (2) The... Certification Test—Method 27 or Periodic Railcar Bubble Leak Test Procedure. (ii) Cargo tank owner's name and...
NASA Technical Reports Server (NTRS)
Underwood, Steve; Lvovsky, Oleg
2007-01-01
The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.
Booth, Eugene T.
1976-02-24
A method and apparatus for determining the position of and estimating the size of leaks in an evacuating apparatus comprising the use of a testing gas such as helium or hydrogen flowing around said apparatus whereby the testing gas will be drawn in at the site of any leaks.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.; JOHNS, B.R.
1999-12-21
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
2000-02-28
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
1999-08-11
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
JOHNS, B.R.
1999-05-05
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
1999-10-26
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
JOHNS, B.R.; KOCH, M.R.
2000-01-28
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Damgaard, Rasmus; Rasmussen, Mats; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton
2013-01-01
In Part 1 of this three-part research series, a leak test performed using high-voltage leak detection (HVLD) technology, also referred to as an electrical conductivity and capacitance leak test, was developed and validated for container-closure integrity verification of a small-volume laminate plastic bag containing an aqueous solution for injection. The sterile parenteral product is the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®, by Novo Nordisk A/S, Bagsværd, Denmark). The aseptically filled and sealed package is designed to preserve product sterility through expiry. Method development and validation work incorporated positive control packages with a single hole laser-drilled through the laminate film of each bag. A unique HVLD method characterized by specific high-voltage and potentiometer set points was established for testing bags positioned in each of three possible orientations as they are conveyed through the instrument's test zone in each of two possible directions-resulting in a total of six different test method options. Validation study results successfully demonstrated the ability of all six methods to accurately and reliably detect those packages with laser-drilled holes from 2.5-11.2 μm in nominal diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product physico-chemical stability. In this Part 1 of a three-part research series, a leak test method based on electrical conductivity and capacitance, called high voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with an insulin pharmaceutical solution for human injection by Novo Nordisk A/S (Bagsværd, Denmark). To perform the test, the package is electrically grounded while being conveyed past an electrode linked to a high-voltage, low-amperage transformer. The instrument measures the current that passes from the transformer to the electrode, through the packaged product and along the package walls, to the ground. Plastic packages without defect are relatively nonconductive and yield a low voltage reading; a leaking package with electrically conductive solution located in or near the leak triggers a spike in voltage reading. Test methods were optimized and validated, enabling the detection of leaking packages with holes as small as 2.5 μm in diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product stability.
Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Mulhall, Brian; Guazzo, Dana Morton
2009-01-01
Part 1 of this series demonstrated that a container closure integrity test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method using a VeriPac 325/LV vacuum decay leak tester by Packaging Technologies & Inspection, LLC (PTI) is capable of detecting leaks > or = 5.0 microm (nominal diameter) in rigid, nonporous package systems, such as prefilled glass syringes. The current study compared USP, Ph.Eur. and ISO dye ingress integrity test methods to PTI's vacuum decay technology for the detection of these same 5-, 10-, and 15-microm laser-drilled hole defects in 1-mL glass prefilled syringes. The study was performed at three test sites using several inspectors and a variety of inspection conditions. No standard dye ingress method was found to reliably identify all holed syringes. Modifications to these standard dye tests' challenge conditions increased the potential for dye ingress, and adjustments to the visual inspection environment improved dye ingress detection. However, the risk of false positive test results with dye ingress tests remained. In contrast, the nondestructive vacuum decay leak test method reliably identified syringes with holes > or = 5.0 microm.
NASA Astrophysics Data System (ADS)
Holland, Stephen D.; Song, Jun-Ho; Chimenti, D. E.; Roberts, Ron
2006-03-01
We demonstrate an array sensor method intended to locate leaks in manned spacecraft using leak-generated, structure-borne ultrasonic noise. We have developed and tested a method for sensing and processing leak noise to reveal the leak location involving the use of a 64-element phased-array. Cross-correlations of ultrasonic noise waveforms from a leak into vacuum have been used with a phased-array analysis to find the direction from the sensor to the leak. This method measures the propagation of guided ultrasonic Lamb waves passing under the PZT array sensor in the spacecraft skin structure. This paper will describe the custom-designed array with integrated electronics, as well as the performance of the array in prototype applications. We show that this method can be used to successfully locate leaks to within a few millimeters on a 0.6-m square aluminum plate.
Rapid Surface Detection of CO2 Leaks from Geologic Sequestration Sites
NASA Astrophysics Data System (ADS)
Moriarty, D. M.; Krevor, S. C.; Benson, S. M.
2013-12-01
Carbon sequestration is becoming a viable option for global CO2 mitigation but effective monitoring methods are needed assure the carbon dioxide stays underground. Above surface monitoring using a mobile gas analyzer is one such method (e.g. Krevor et al., 2010). The Picarro gas analyzer uses wavelength-scanned cavity ring down spectroscopy to accurately identify concentrations of various atmospheric gases including their isotopic composition. These measurements can then be used for anomaly (leak) detection and source attribution. Leaks are detected by anomalous absolute concentration of CO2 and anomalous δ13C values. Source attribution is determined by the isotopic concentrations of the identified leaking gas. To distinguish between noise from ambient signals and leaks, a method based on mixing ratios has been developed. A newly acquired data set presented here has been collected from a 3.7km2 area with naturally occurring CO2 springs near Green River, Utah. All of the areas of known leakage were readily detected using this method along with several other areas that showed significant signs of leakage. In addition, testing on the Stanford campus has shown that this method is sensitive enough to distinguish between open fields and roadways. Another data set is being collected at Montana State University at the ZERT monitoring test site where an artificial leak has been created for the purpose of testing leak detection and quantification methods. Data collected from this site are being used for (1) assessing of detection levels and how they depend on environmental parameters such as wind speed, and acquisition variables such as sample rate and traverse speed, (2) optimizing acquisition parameters to increase detection levels and increase confidence in leak detection, (3) evaluating the potential for quantifying the magnitude of the leak and (4) spatial data analysis to identify the most probable leak locations.
40 CFR 63.1046 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Method 21 of 40 CFR part 60, appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... 60, appendix A. (7) Each potential leak interface shall be checked by traversing the instrument probe...
40 CFR 63.1046 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Method 21 of 40 CFR part 60, appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... 60, appendix A. (7) Each potential leak interface shall be checked by traversing the instrument probe...
40 CFR 63.1046 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Method 21 of 40 CFR part 60, appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... 60, appendix A. (7) Each potential leak interface shall be checked by traversing the instrument probe...
40 CFR 63.945 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated... determined according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak...
40 CFR 63.945 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated... determined according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak...
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.945 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated... determined according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak...
Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM
2012-06-19
A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
Thornberg, Steven M; Brown, Jason
2015-02-17
A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
Leak test fixture and method for using same
Hawk, Lawrence S.
1976-01-01
A method and apparatus are provided which are especially useful for leak testing seams such as an end closure or joint in an article. The test does not require an enclosed pressurized volume within the article or joint section to be leak checked. A flexible impervious membrane is disposed over an area of the seamed surfaces to be leak checked and sealed around the outer edges. A preselected vacuum is applied through an opening in the membrane to evacuate the area between the membrane and the surface being leak checked to essentially collapse the membrane to conform to the article surface or joined adjacent surfaces. A pressure differential is concentrated at the seam bounded by the membrane and only the seam experiences a pressure differential as air or helium molecules are drawn into the vacuum system through a leak in the seam. A helium detector may be placed in a vacuum exhaust line from the membrane to detect the helium. Alternatively, the vacuum system may be isolated at a preselected pressure and leaks may be detected by a subsequent pressure increase in the vacuum system.
Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal
NASA Technical Reports Server (NTRS)
Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.
2011-01-01
Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the experimentally obtained air leak rate data suggest that neither conversion factor can be used alone to accurately convert helium leak rates to equivalent air leak rates for the test seals evaluated in this study; other leak phenomena, including permeation, must also be considered.
Natural air leak test without submergence for spontaneous pneumothorax.
Uramoto, Hidetaka; Tanaka, Fumihiro
2011-12-24
Postoperative air leaks are frequent complications after surgery for a spontaneous pneumothorax (SP). We herein describe a new method to test for air leaks by using a transparent film and thoracic tube in a closed system. Between 2005 and 2010, 35 patients underwent a novel method for evaluating air leaks without submergence, and their clinical records were retrospectively reviewed. The data on patient characteristics, surgical details, and perioperative outcomes were analyzed. The differences in the clinical background and intraoperative factors did not reach a statistically significant level between the new and classical methods. The incidence of recurrence was also equivalent to the standard method. However, the length of the operation and drainage periods were significantly shorter in patients evaluated using the new method than the conventional method. Further, no postoperative complications were observed in patients evaluated using the new method. This simple technique is satisfactorily effective and does not result in any complications.
Leak test adapter for containers
Hallett, Brian H.; Hartley, Michael S.
1996-01-01
An adapter is provided for facilitating the charging of containers and leak testing penetration areas. The adapter comprises an adapter body and stem which are secured to the container's penetration areas. The container is then pressurized with a tracer gas. Manipulating the adapter stem installs a penetration plug allowing the adapter to be removed and the penetration to be leak tested with a mass spectrometer. Additionally, a method is provided for using the adapter.
McAdams, Wm.A.; Foss, M.H.
1958-08-12
A method of testing containers for leaks is described, particularly the testing of containers or cans in which the uranium slugs for nuelear reactors are jacketed. This method involves the immersion of the can in water under l50 pounds of pressure, then removing, drying, and coating the can with anhydrous copper sulfate. Amy water absorbed by the can under pressure will exude and discolor the copper sulfate in the area about the leak.
Assessing Surgeon Behavior Change after Anastomotic Leak in Colorectal Surgery
Simianu, Vlad V.; Basu, Anirban; Alfonso-Cristancho, Rafael; Thirlby, Richard C.; Flaxman, Abraham D.; Flum, David R.
2016-01-01
Background Recency effect suggests that people disproportionately value events from the immediate past when making decisions, but the extent of this impact on surgeons’ decisions is unknown. This study evaluates for recency effect in surgeons by examining use of preventative leak testing before and after colorectal operations with anastomotic leaks. Materials and Methods Prospective cohort of adult patients (≥18 years) undergoing elective colorectal operations at Washington State hospitals participating in the Surgical Care and Outcomes Assessment Program (2006–2013). The main outcome measure was surgeons’ change in leak testing from 6 months before to 6 months after an anastomotic leak occurred. Results Across 4,854 elective colorectal operations performed by 282 surgeons at 44 hospitals, there was a leak rate of 2.6% (n=124). The 40 leaks (32%) in which the anastomosis was not tested occurred across 25 surgeons. While the ability to detect an overall difference in use of leak testing was limited by small sample size, 9 (36%) of 25 surgeons increased their leak testing by 5 percent points or more after leaks in cases where the anastomosis was not tested. Surgeons who increased their leak testing more frequently performed operations for diverticulitis (45% vs 33%), more frequently began their cases laparoscopically (65% vs 37%), and had longer mean operative times (195±99 vs 148±87 minutes), all p<0.001. Conclusions Recency effect was demonstrated by only one-third of eligible surgeons. Understanding the extent to which clinical decisions may be influenced by recency effect may be important in crafting quality improvement initiatives that require clinician behavior change. PMID:27664886
Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty
NASA Technical Reports Server (NTRS)
Mather, Janice L.; Taylor, Shawn C.
2015-01-01
In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.
Seal Integrity of Selected Fuzes as Measured by Three Leak Test Methods
1976-09-01
the worst fuze from the seal standpoint. The M503A-2 fuze body is made from a cast aluminum alloy . The casting process leaves voids which, after...leak resistance of the joint. WDU4A/A The design of this fuze depends upon ultrasonic welding to seal lid to case. The specified leak test merely...test is probably one of the better leakage tests from an effectiveness standpoint. However, from lot quantities of 690 and 480, reject rates of 20% were
Method and apparatus for container leakage testing
Kronberg, James W.
1995-01-01
An apparatus for use in one-hundred percent leak testing of food containers used in conjunction with a tracer gas. The apparatus includes a shell with entrance and exit air locks to create a controlled atmosphere through which a series of containers is conveyed by a conveyor belt. The pressure in the shell is kept lower than the pressure in the containers and the atmosphere is made to flow with the containers so that a tracer gas placed in the packages before sealing them will leak more readily, but the leaked tracer gas will remain associated with the leaking package as it moves through the shell. The leaks are detected with a sniffer probe in fluid communication with a gas chromatograph. The gas chromatograph issues a signal when it detects a leak to an ejector that will eject the leaking container from the conveyor. The system is timed so that the series of containers can move continuously into and out of the shell, past the probe and the ejector, without stopping, yet each package is tested for leaks and removed if leaking.
Small-target leak detection for a closed vessel via infrared image sequences
NASA Astrophysics Data System (ADS)
Zhao, Ling; Yang, Hongjiu
2017-03-01
This paper focus on a leak diagnosis and localization method based on infrared image sequences. Some problems on high probability of false warning and negative affect for marginal information are solved by leak detection. An experimental model is established for leak diagnosis and localization on infrared image sequences. The differential background prediction is presented to eliminate the negative affect of marginal information on test vessel based on a kernel regression method. A pipeline filter based on layering voting is designed to reduce probability of leak point false warning. A synthesize leak diagnosis and localization algorithm is proposed based on infrared image sequences. The effectiveness and potential are shown for developed techniques through experimental results.
40 CFR 280.44 - Methods of release detection for piping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...
40 CFR 280.44 - Methods of release detection for piping.
Code of Federal Regulations, 2011 CFR
2011-07-01
... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...
40 CFR 280.44 - Methods of release detection for piping.
Code of Federal Regulations, 2013 CFR
2013-07-01
... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...
40 CFR 280.44 - Methods of release detection for piping.
Code of Federal Regulations, 2014 CFR
2014-07-01
... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...
40 CFR 280.44 - Methods of release detection for piping.
Code of Federal Regulations, 2010 CFR
2010-07-01
... accordance with the following: (a) Automatic line leak detectors. Methods which alert the operator to the... pounds per square inch line pressure within 1 hour. An annual test of the operation of the leak detector...
High-sensitivity Leak-testing Method with High-Resolution Integration Technique
NASA Astrophysics Data System (ADS)
Fujiyoshi, Motohiro; Nonomura, Yutaka; Senda, Hidemi
A high-resolution leak-testing method named HR (High-Resolution) Integration Technique has been developed for MEMS (Micro Electro Mechanical Systems) sensors such as a vibrating angular-rate sensor housed in a vacuum package. Procedures of the method to obtain high leak-rate resolution were as follows. A package filled with helium gas was kept in a small accumulation chamber to accumulate helium gas leaking from the package. After the accumulation, the accumulated helium gas was introduced into a mass spectrometer in a short period of time, and the flux of the helium gas was measured by the mass spectrometer as a transient phenomenon. The leak-rate of the package was calculated from the detected transient waveform of the mass spectrometer and the accumulation time of the helium gas in the accumulation chamber. Because the density of the helium gas in the vacuum chamber increased and the accumulated helium gas was measured in a very short period of time with the mass spectrometer, the peak strength of the transient waveform became high and the signal to noise ratio was much improved. The detectable leak-rate resolution of the technique reached 1×10-15 (Pa·m3/s). This resolution is 103 times superior to that of the conventional helium vacuum integration method. The accuracy of the measuring system was verified with a standard helium gas leak source. The results were well matched between theoretical calculation based on the leak-rate of the source and the experimental results within only 2% error.
Detecting well casing leaks in Bangladesh using a salt spiking method
Stahl, M.O.; Ong, J.B.; Harvey, C.F.; Johnson, C.D.; Badruzzaman, A.B.M.; Tarek, M.H.; VanGeen, A.; Anderson, J.A.; Lane, J.W.
2014-01-01
We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries.
Detecting well casing leaks in Bangladesh using a salt spiking method.
Stahl, M O; Ong, J B; Harvey, C F; Johnson, C D; Badruzzaman, A B M; Tarek, M H; van Geen, A; Anderson, J A; Lane, J W
2014-09-01
We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries. © 2014, National Ground Water Association.
Morrical, Bradley D; Goverde, Marcel; Grausse, Jean; Gerwig, Tanja; Vorgrimler, Lothar; Morgen, Rachel; Büttiker, Jean-Pierre
2007-01-01
A direct test method using helium leak detection was developed to determine microbial ingress in parenteral vial/rubber closure systems. The purpose of this study was to establish a direct correlation between the helium leak rate and the presence of ingress when vials were submersed under pressure in a broth of bacteria. Results were obtained for two different types of leaks: microholes that have been laser-drilled into thin metal plates, and thin copper wire that was placed between the rubber closure and the glass vial's sealing surface. The results from the microholes showed that the helium leak rate was a function of the square of the hole diameter and fit well with theoretical calculations. The relationship with the wire gave a far more complex dependence and was not modeled theoretically. Comparison with the microbial challenge showed that for microholes a lower size limit was found to be 2 microm with a corresponding leak rate of 1.4 x 10(-3) mbarl/s. For the fine wire experiment the lower limit was 15-microm wire and a corresponding leak rate of 1.3 x 10(-5) mbarl/s. From these tests a safe, lower limit, leak rate was established.
EVALUATION OF VOLUMETRIC LEAK DETECTION METHODS USED IN UNDERGROUND STORAGE TANKS
In the spring and summer of 1987, the United States Environmental Protection Agency (EPA) evaluated the performance of 25 commercially available volumetric test methods for the detection of small leaks in underground storage tanks containing gasoline. Performance was estimated by...
NASA Technical Reports Server (NTRS)
Nuss, H. E.
1975-01-01
The measuring and evaluation procedure for the determination of leak rates of satellite subsystems with a quadrupole mass spectrometer, and the results of the residual gas analysis are described. The method selected for leak rate determination was placing the system into a vacuum chamber and furnishing the chamber with a mass spectrometer and calibrated leaks. The residual gas of a thermal vacuum test facility, in which the thermal balance test radiation input was simulated by a heated canister, was analyzed with the mass spectrometer in the atomic mass unit range up to 300 amu. In addition to the measurements during the space environment tests, mass spectrometric studies were performed with samples of spacecraft materials. The studies were carried out during tests for the projects HELIOS, AEROS B and SYMPHONIE.
Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine
NASA Technical Reports Server (NTRS)
Schwabacher, Mark A.; Aguilar, Robert; Figueroa, Fernando F.
2009-01-01
The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.
Controlling air leaks using free pericardial fat pads as surgical sealant in pulmonary resection.
Ikeda, Takeshi; Sasaki, Masato; Yamada, Narihisa; Takamori, Atsushi; Tanabe, Sawaka; Okada, Akitoshi; Sakon, Kayo; Mizunaga, Tae; Koshiji, Takaaki
2015-04-01
This study evaluated the feasibility and efficacy of a new operative method for controlling intraoperative air leaks using free pericardial fat pads as a covering sealant in pulmonary resection. To manage air leaks that must be controlled in pulmonary resection at the first water sealing test, collected free pericardial fat was used as a covering sealant and sewn on by the suture closing the lesion. In cases of uncontrolled air leaks at the second sealing test, fibrin glue was used to fill the residual lesion between the fat and visceral pleura. Fifty-one eligible patients were enrolled in this study to evaluate the duration of postoperative air leaks and the condition of the implanted fat on chest computed tomography (CT) 6 months later. The mean duration of postoperative air leaks was 1.05 ± 1.84 days in the 39 cases that received the pericardial fat covering technique only and 2.66 ± 3.42 days in the 12 cases that received the pericardial fat covering technique combined with fibrin glue. Prolonged alveolar air leaks occurred in 1 case and 2 cases, respectively. No cases required conversion to conventional methods, and there were no further adverse events. On follow-up chest CT approximately 62.7% of obvious engrafted fat survived. Using free pericardial fat pads as a sealant to control air leaks in pulmonary resection is safe and has good feasibility and potent efficacy. This new method can be an innovative technique for preventing prolonged air leaks. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Testing of heat exchangers in membrane oxygenators using air pressure.
Hamilton, Carole; Stein, Jutta; Seidler, Rainer; Kind, Robert; Beck, Karin; Tosok, Jürgen; Upterfofel, Jörg
2006-03-01
All heat exchangers (HE) in membrane oxygenators are tested by the manufacturer for water leaks during the production phase. However, for safety reasons, it is highly recommended that HEs be tested again before clinical use. The most common method is to attach the heater-cooler to the HE and allow the water to recirculate for at least 10 min, during which time a water leak should be evident. To improve the detection of water leaks, a test was devised using a pressure manometer with an integrated bulb used to pressurize the HE with air. The cardiopulmonary bypass system is set up as per protocol. A pressure manometer adapted to a 1/2" tubing is connected to the water inlet side of the oxygenator. The water outlet side is blocked with a short piece of 1/2" deadend tubing. The HE is pressurized with 250 mmHg for at least 30 sec and observed for any drop. Over the last 2 years, only one oxygenator has been detected with a water leak in which the air-method leaktest was performed. This unit was sent back to the manufacturer who confirmed the failure. Even though the incidence of water leaks is very low, it does occur and it is, therefore, important that all HEs are tested before they are used clinically. This method of using a pressure manometer offers many advantages, as the HE can be tested outside of the operating room (OR), allowing earlier testing of the oxygenator, no water contact is necessary, and it is simple, easy and quick to perform.
Rasmussen, Mats; Damgaard, Rasmus; Buus, Peter; Guazzo, Dana Morton
2013-01-01
This Part 3 of this three-part research series reports the impact of high-voltage leak detection (HVLD) exposure on the physico-chemical stability of the packaged product. The product, intended for human administration by injection, is an aqueous solution formulation of the rapid acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. The package is a small-volume form-fill-seal plastic laminate bag. Product-packages exposed to HVLD were compared to unexposed product after storage for 9 months at recommended storage conditions of 5 ± 3 °C. No differences in active ingredient or degradation products assays were noted. No changes in any other stability indicating parameter results were observed. This report concludes this three-part series. Part 1 documented HVLD method development and validation work. Part 2 explored the impact of various package material, package temperature, and package storage conditions on HVLD test results. Detection of leaks in the bag seal area was investigated. In conclusion, HVLD is reported to be a validatable leak test method suitable for rapid, nondestructive container-closure integrity evaluation of the subject product-package. In Part 1 of this three-part series, a leak test method based on electrical conductivity and capacitance, also called high-voltage leak detection (HVLD), was proven to find hole leaks in small plastic bags filled with a solution of insulin aspart intended for human injection (NovoRapid®/NovoLog® by Novo Nordisk A/S, Bagsværd, Denmark). In Part 2, the ability of the HVLD method to find other types of package leaks was tested, and the impact of package material and product storage temperature on HVLD results was explored. This final Part 3 checked how well the packaged protein drug solution maintained its potency after HVLD exposure over 9 months of storage under long-term stability conditions. Results showed that HVLD caused no harm to the product.
Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method
NASA Astrophysics Data System (ADS)
Arai, Kenta; Yoshida, Hajime
2014-10-01
Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.
Standard Test Procedures for Evaluating Various Leak Detection Methods
Learn about protocols that testers could use to demonstrate that an individual release detection equipment type could meet the performance requirements noted in the federal UST requirements for detecting leaks.
Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.
Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J
2016-03-01
Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.
NASA Astrophysics Data System (ADS)
Alden, Caroline B.; Ghosh, Subhomoy; Coburn, Sean; Sweeney, Colm; Karion, Anna; Wright, Robert; Coddington, Ian; Rieker, Gregory B.; Prasad, Kuldeep
2018-03-01
Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model-data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10-5 kg s-1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1σ), when measurements are averaged over 2 min. The results of the synthetic and field data testing show that the new observing system and statistical approach greatly decreases the incidence of false alarms (that is, wrongly identifying a well site to be leaking) compared with the same tests that do not use the NZMB approach and therefore offers increased leak detection and sizing capabilities.
Experience with helium leak and thermal shocks test of SST-1 cryo components
NASA Astrophysics Data System (ADS)
Sharma, Rajiv; Nimavat, Hiren; Srikanth, G. L. N.; Bairagi, Nitin; Shah, Pankil; Tanna, V. L.; Pradhan, S.
2012-11-01
A steady state superconducting Tokamak SST-1 is presently under its assembly stage at the Institute for Plasma Research. The SST-1 machine is a family of Superconducting SC coils for both Toroidal field and Poloidal Field. An ultra high vacuum compatible vacuum vessel, placed in the bore of the TF coils, houses the plasma facing components. A high vacuum cryostat encloses all the SC coils and the vacuum vessel. Liquid Nitrogen (LN2) cooled thermal shield between the vacuum vessel & SC coils as well as between cryostat and the SC coils. There are number of crucial cryogenic components as Electrical isolators, 80 K thermal shield, Cryogenic flexible hose etc., which have to be passed the performance validation tests as part of fulfillment of the stringent QA/QC before incorporated in the main assembly. The individual leak tests of components at RT as well as after thermal cycle from 300 K to 77 K ensure us to make final overall leak proof system. These components include, Large numbers of Electrical Isolators for Helium as well as LN2 services, Flexible Bellows and Hoses for Helium as well as LN2 services, Thermal shock tests of large numbers of 80 K Bubble shields In order to validate the helium leak tightness of these components, we have used the calibrated mass spectrometer leak detector (MSLD) at 300 K, 77 K and 4.2. Since it is very difficult to locate the leaks, which are appearing at rather lower temperatures e.g. less than 20 K, We have invented different approaches to resolve the issue of such leaks. This paper, in general describes the design of cryogenic flexible hose, assembly, couplings for leak testing, test method and techniques of thermal cycles test at 77 K inflow conditions and leak testing aspects of different cryogenic components. The test results, the problems encountered and its solutions techniques are discussed.
What is the optimal management of an intra-operative air leak in a colorectal anastomosis?
Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R
2018-02-01
An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
NASA Technical Reports Server (NTRS)
Hammock, William R., Jr.; Cota, Phillip E., Jr.; Rosenbaum, Bernard J.; Barrett, Michael J.
1991-01-01
Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.
Rasmussen, Mats; Damgaard, Rasmus; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton
2013-01-01
Part 1 of this three-part research series detailed the development and validation of a high-voltage leak detection test (HVLD, also known as an electrical conductivity and capacitance test) for verifying the container-closure integrity of a small-volume laminate plastic bag containing an aqueous solution formulation of the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. Leak detection capability was verified using positive controls each with a single laser-drilled hole in the bag film face. In this Part 2, HVLD leak detection capability was further explored in four separate studies. Study 1 investigated the ability of HVLD to detect weaknesses and/or gaps in the bag heat seal. Study 2 checked the HVLD detection of bag holes in packages stored 4 days at ambient conditions followed by 17 days at refrigeration. Study 3 examined HVLD test results for packages tested when cold. Study 4 compared HVLD test results as a function of bag plastic film lots. The final Part 3 of this series will report the impact of HVLD exposure on product visual appearance and chemical stability. In Part 1 of this three-part series, a leak test method based on electrical conductivity and capacitance, also called high-voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with a solution for injection of the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. In this Part 2, HVLD leak detection capability was further explored in four separate studies. Study 1 investigated the ability of HVLD to detect bag heat seal leaks. Study 2 checked HVLD's ability to detect bag holes after a total of 21 days at ambient plus refrigerated temperatures. Study 3 looked to see if HVLD results changed for packages tested when still cold. Study 4 compared HVLD results for multiple bag plastic film lots. The final Part 3 of this series will report any evidence of drug component degradation caused by HVLD exposure.
Leak localization and quantification with a small unmanned aerial system
NASA Astrophysics Data System (ADS)
Golston, L.; Zondlo, M. A.; Frish, M. B.; Aubut, N. F.; Yang, S.; Talbot, R. W.
2017-12-01
Methane emissions from oil and gas facilities are a recognized source of greenhouse gas emissions, requiring cost-effective and reliable monitoring systems to support leak detection and repair programs. We describe a set of methods for locating and quantifying natural gas leaks using a small unmanned aerial system (sUAS) equipped with a path-integrated methane sensor along with ground-based wind measurements. The algorithms are developed as part of a system for continuous well pad scale (100 m2 area) monitoring, supported by a series of over 200 methane release trials covering multiple release locations and flow rates. Test measurements include data obtained on a rotating boom platform as well as flight tests on a sUAS. The system is found throughout the trials to reliably distinguish between cases with and without a methane release down to 6 scfh (0.032 g/s). Among several methods evaluated for horizontal localization, the location corresponding to the maximum integrated methane reading have performed best with a median error of ± 1 m if two or more flights are averaged, or ± 1.2 m for individual flights. Additionally, a method of rotating the data around the estimated leak location is developed, with the leak magnitude calculated as the average crosswind integrated flux in the region near the source location. Validation of these methods will be presented, including blind test results. Sources of error, including GPS uncertainty, meteorological variables, and flight pattern coverage, will be discussed.
Assessing the accuracy of TDR-based water leak detection system
NASA Astrophysics Data System (ADS)
Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.
2018-03-01
The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.
Code of Federal Regulations, 2014 CFR
2014-07-01
... or an alternative external leak test technique may be required for samplers whose design or... alternative internal, filter bypass leak test technique may be required for samplers whose design or... variation or better has been established for the operational precision of PM2.5 monitoring data. 5.1 Tests...
Code of Federal Regulations, 2012 CFR
2012-07-01
... or an alternative external leak test technique may be required for samplers whose design or... alternative internal, filter bypass leak test technique may be required for samplers whose design or... variation or better has been established for the operational precision of PM2.5 monitoring data. 5.1 Tests...
Code of Federal Regulations, 2013 CFR
2013-07-01
... or an alternative external leak test technique may be required for samplers whose design or... alternative internal, filter bypass leak test technique may be required for samplers whose design or... variation or better has been established for the operational precision of PM2.5 monitoring data. 5.1 Tests...
Transepithelial leak in Barrett's esophagus patients: The role of proton pump inhibitors
Farrell, Christopher; Morgan, Melissa; Tully, Owen; Wolov, Kevin; Kearney, Keith; Ngo, Benjamin; Mercogliano, Giancarlo; Thornton, James J; Valenzano, Mary Carmen; Mullin, James M
2012-01-01
AIM: To determine if the observed paracellular sucrose leak in Barrett’s esophagus patients is due to their proton pump inhibitor (PPI) use. METHODS: The in vivo sucrose permeability test was administered to healthy controls, to Barrett’s patients and to non-Barrett’s patients on continuous PPI therapy. Degree of leak was tested for correlation with presence of Barrett’s, use of PPIs, and length of Barrett’s segment and duration of PPI use. RESULTS: Barrett’s patients manifested a near 3-fold greater, upper gastrointestinal sucrose leak than healthy controls. A decrease of sucrose leak was observed in Barrett’s patients who ceased PPI use for 7 d. Although initial introduction of PPI use (in a PPI-naïve population) results in dramatic increase in sucrose leak, long-term, continuous PPI use manifested a slow spontaneous decline in leak. The sucrose leak observed in Barrett’s patients showed no correlation to the amount of Barrett’s tissue present in the esophagus. CONCLUSION: Although future research is needed to determine the degree of paracellular leak in actual Barrett’s mucosa, the relatively high degree of leak observed with in vivo sucrose permeability measurement of Barrett’s patients reflects their PPI use and not their Barrett’s tissue per se. PMID:22719187
NASA Astrophysics Data System (ADS)
Wang, Xun; Ghidaoui, Mohamed S.
2018-07-01
This paper considers the problem of identifying multiple leaks in a water-filled pipeline based on inverse transient wave theory. The analytical solution to this problem involves nonlinear interaction terms between the various leaks. This paper shows analytically and numerically that these nonlinear terms are of the order of the leak sizes to the power two and; thus, negligible. As a result of this simplification, a maximum likelihood (ML) scheme that identifies leak locations and leak sizes separately is formulated and tested. It is found that the ML estimation scheme is highly efficient and robust with respect to noise. In addition, the ML method is a super-resolution leak localization scheme because its resolvable leak distance (approximately 0.15λmin , where λmin is the minimum wavelength) is below the Nyquist-Shannon sampling theorem limit (0.5λmin). Moreover, the Cramér-Rao lower bound (CRLB) is derived and used to show the efficiency of the ML scheme estimates. The variance of the ML estimator approximates the CRLB proving that the ML scheme belongs to class of best unbiased estimator of leak localization methods.
The results of gas permeability and leak testing during active soil-gas sampling at Hal’s Chevron LUST Site in Green River, Utah are presented. This study was conducted to support development of a passive soil-gas sampling method. Gas mixtures containing helium and methane were...
Weld leaks rapidly and safely detected
NASA Technical Reports Server (NTRS)
1965-01-01
Test method detects leaks that occur during hydrostatic pressure testing of welded joints in metal tanks. A strip of aluminum foil and a strip of water-soluble paper are placed over the weld. A voltage applied between the tank wall and the foil strip is monitored to detect a decrease in ohmic resistance caused by water leakage into the paper layer.
NASA Astrophysics Data System (ADS)
Wang, Ji; Zhang, Ru; Yan, Yuting; Dong, Xiaoqiang; Li, Jun Ming
2017-05-01
Hazardous gas leaks in the atmosphere can cause significant economic losses in addition to environmental hazards, such as fires and explosions. A three-stage hazardous gas leak source localization method was developed that uses movable and stationary gas concentration sensors. The method calculates a preliminary source inversion with a modified genetic algorithm (MGA) and has the potential to crossover with eliminated individuals from the population, following the selection of the best candidate. The method then determines a search zone using Markov Chain Monte Carlo (MCMC) sampling, utilizing a partial evaluation strategy. The leak source is then accurately localized using a modified guaranteed convergence particle swarm optimization algorithm with several bad-performing individuals, following selection of the most successful individual with dynamic updates. The first two stages are based on data collected by motionless sensors, and the last stage is based on data from movable robots with sensors. The measurement error adaptability and the effect of the leak source location were analyzed. The test results showed that this three-stage localization process can localize a leak source within 1.0 m of the source for different leak source locations, with measurement error standard deviation smaller than 2.0.
Eleventh interim status report: Model 9975 O-Ring fixture long-term leak performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2016-08-01
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determinemore » if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.« less
Tenth interim status report: Model 9975 O-ring fixture long-term leak performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
2015-08-26
A series of experiments to monitor the aging performance of Viton ® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 °F. They were leak-tested initially and have been tested periodically tomore » determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 °F.« less
Shimasaki, Noriko; Hara, Masayuki; Kikuno, Ritsuko; Shinohara, Katsuaki
2016-01-01
To prevent nosocomial infections caused by even either Ebola virus or methicillin-resistant Staphylococcus aureus (MRSA), healthcare workers must wear the appropriate protective clothing which can inhibit contact transmission of these pathogens. Therefore, it is necessary to evaluate the performance of protective clothing for penetration resistance against infectious agents. In Japan, some standard methods were established to evaluate the penetration resistance of protective clothing fabric materials under applied pressure. However, these methods only roughly classified the penetration resistance of fabrics, and the detection sensitivity of the methods and the penetration amount with respect to the relationship between blood and the pathogen have not been studied in detail. Moreover, no standard method using bacteria for evaluation is known. Here, to evaluate penetration resistance of protective clothing materials under applied pressure, the detection sensitivity and the leak amount were investigated by using synthetic blood containing bacteriophage phi-X174 or S. aureus. And the volume of leaked synthetic blood and the amount of test microbe penetration were simultaneously quantified. Our results showed that the penetration detection sensitivity achieved using a test microbial culture was higher than that achieved using synthetic blood at invisible leak level pressures. This finding suggested that there is a potential risk of pathogen penetration even when visual leak of contaminated blood through the protective clothing was not observed. Moreover, at visible leak level pressures, it was found that the amount of test microbe penetration varied at least ten-fold among protective clothing materials classified into the same class of penetration resistance. Analysis of the penetration amount revealed a significant correlation between the volume of penetrated synthetic blood and the amount of test microbe penetration, indicating that the leaked volume of synthetic blood could be considered as a latent indicator for infection risk, that the amount of exposure to contaminated blood corresponds to the risk of infection. Our study helped us ascertain, with high sensitivity, the differences among fabric materials with respect to their protective performance, which may facilitate effective selection of protective clothing depending on the risk assessment.
Infrared video based gas leak detection method using modified FAST features
NASA Astrophysics Data System (ADS)
Wang, Min; Hong, Hanyu; Huang, Likun
2018-03-01
In order to detect the invisible leaking gas that is usually dangerous and easily leads to fire or explosion in time, many new technologies have arisen in the recent years, among which the infrared video based gas leak detection is widely recognized as a viable tool. However, all the moving regions of a video frame can be detected as leaking gas regions by the existing infrared video based gas leak detection methods, without discriminating the property of each detected region, e.g., a walking person in a video frame may be also detected as gas by the current gas leak detection methods.To solve this problem, we propose a novel infrared video based gas leak detection method in this paper, which is able to effectively suppress strong motion disturbances.Firstly, the Gaussian mixture model(GMM) is used to establish the background model.Then due to the observation that the shapes of gas regions are different from most rigid moving objects, we modify the Features From Accelerated Segment Test (FAST) algorithm and use the modified FAST (mFAST) features to describe each connected component. In view of the fact that the statistical property of the mFAST features extracted from gas regions is different from that of other motion regions, we propose the Pixel-Per-Points (PPP) condition to further select candidate connected components.Experimental results show that the algorithm is able to effectively suppress most strong motion disturbances and achieve real-time leaking gas detection.
Study to develop improved methods to detect leakage in fluid systems, phase 2
NASA Technical Reports Server (NTRS)
Janus, J. C.; Cimerman, I.
1971-01-01
An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.
Endotracheal tube leak pressure and tracheal lumen size in swine.
Finholt, D A; Audenaert, S M; Stirt, J A; Marcella, K L; Frierson, H F; Suddarth, L T; Raphaely, R C
1986-06-01
Endotracheal tube "leak" is often estimated in children to judge the fit of uncuffed endotracheal tubes within the trachea. Twenty-five swine were intubated with uncuffed tracheal tubes to determine whether a more sensitive measurement of leaks could be devised and whether leak pressure estimates fit between tracheal tube and trachea. We compared leak pressure measurement using a stethoscope and aneroid manometer with a technique using a microphone, pressure transducer, and recorder, and found no differences between the two methods. The tracheas were then removed and slides prepared of tracheal cross-sectional specimens. Regression analysis revealed a linear relationship between tracheal lumen size and tracheal tube size for both low leak pressure (y = -0.4 + 0.79x, r = 0.88, P less than 0.05) and high leak pressure (y = -2.9 + 0.71x, r = 0.92, P less than 0.05) groups. We conclude that leak testing with a stethoscope and aneroid manometer is sensitive and accurate, and that tracheal tube leak pressure accurately portrays fit between tube and trachea.
40 CFR 264.1063 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Test methods and procedures. 264.1063... Air Emission Standards for Equipment Leaks § 264.1063 Test methods and procedures. (a) Each owner or operator subject to the provisions of this subpart shall comply with the test methods and procedures...
Leak Location and Classification in the Space Shuttle Main Engine Nozzle by Infrared Testing
NASA Technical Reports Server (NTRS)
Russell, Samuel S.; Walker, James L.; Lansing, Mathew
2003-01-01
The Space Shuttle Main Engine (SSME) is composed of cooling tubes brazed to the inside of a conical structural jacket. Because of the geometry there are regions that can't be inspected for leaks using the bubble solution and low-pressure method. The temperature change due escaping gas is detectable on the surface of the nozzle under the correct conditions. The methods and results presented in this summary address the thermographic identification of leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute temperature change associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.
Integrity of Disposable Nitrile Exam Gloves Exposed to Simulated Movement
Phalen, Robert N.; Wong, Weng Kee
2011-01-01
Every year, millions of health care, first responder, and industry workers are exposed to chemical and biological hazards. Disposable nitrile gloves are a common choice as both a chemical and physical barrier to these hazards, especially as an alternative to natural latex gloves. However, glove selection is complicated by the availability of several types or formulations of nitrile gloves, such as low-modulus, medical-grade, low-filler, and cleanroom products. This study evaluated the influence of simulated movement on the physical integrity (i.e., holes) of different nitrile exam glove brands and types. Thirty glove products were evaluated out-of-box and after exposure to simulated whole-glove movement for 2 hr. In lieu of the traditional 1-L water-leak test, a modified water-leak test, standardized to detect a 0.15 ± 0.05 mm hole in different regions of the glove, was developed. A specialized air inflation method simulated bidirectional stretching and whole-glove movement. A worst-case scenario with maximum stretching was evaluated. On average, movement did not have a significant effect on glove integrity (chi-square; p=0.068). The average effect was less than 1% between no movement (1.5%) and movement (2.1%) exposures. However, there was significant variability in glove integrity between different glove types (p ≤ 0.05). Cleanroom gloves, on average, had the highest percentage of leaks, and 50% failed the water-leak test. Low-modulus and medical-grade gloves had the lowest percentages of leaks, and no products failed the water-leak test. Variability in polymer formulation was suspected to account for the observed discrepancies, as well as the inability of the traditional 1-L water-leak test to detect holes in finger/thumb regions. Unexpectedly, greater than 80% of the glove defects were observed in the finger and thumb regions. It is recommended that existing water-leak tests be re-evaluated and standardized to account for product variability. PMID:21476169
NASA Astrophysics Data System (ADS)
Yan, Yong; Cui, Xiwang; Guo, Miao; Han, Xiaojuan
2016-11-01
Seal capacity is of great importance for the safety operation of pressurized vessels. It is crucial to locate the leak hole timely and accurately for reasons of safety and maintenance. This paper presents the principle and application of a linear acoustic emission sensor array and a near-field beamforming technique to identify the location of a continuous CO2 leak from an isotropic flat-surface structure on a pressurized vessel in the carbon capture and storage system. Acoustic signals generated by the leak hole are collected using a linear high-frequency sensor array. Time-frequency analysis and a narrow-band filtering technique are deployed to extract effective information about the leak. The impacts of various factors on the performance of the localization technique are simulated, compared and discussed, including the number of sensors, distance between the leak hole and sensor array and spacing between adjacent sensors. Experiments were carried out on a laboratory-scale test rig to assess the effectiveness and operability of the proposed method. The results obtained suggest that the proposed method is capable of providing accurate and reliable localization of a continuous CO2 leak.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuz'micheva, T.N.; Mazurenok, A.M.; Eliseev, V.P.
The problem of using the chemical method for checking the airtightness of ventilation systems and containment structures with the use of indicator materials on a base of Congo red and an air-ammonia mixture as the test medium was examined. The methods and results of experimental investigations of leaks characteristic for containment structures and ventilation systems are given. Suggestions are given on a determination of the parameters of local leaks and on the practical use of the given method for evaluating the quality of sealing.
Test Report of Special Form Qualification Testing for the ORNL U ZipCan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Oscar A.
This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less
Shimasaki, Noriko; Shinohara, Katsuaki; Morikawa, Hideki
2017-12-07
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task.
SHIMASAKI, Noriko; SHINOHARA, Katsuaki; MORIKAWA, Hideki
2017-01-01
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task. PMID:28978815
Optical Detection Of Cryogenic Leaks
NASA Technical Reports Server (NTRS)
Wyett, Lynn M.
1988-01-01
Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.
46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are not...
40 CFR 1066.985 - Fuel storage system leak test procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Fuel storage system leak test... Refueling Emission Test Procedures for Motor Vehicles § 1066.985 Fuel storage system leak test procedure. (a... conditions. (3) Leak test equipment must have the ability to pressurize fuel storage systems to at least 4.1...
40 CFR 63.1046 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.1046...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1046 Test methods... Method 21 of 40 CFR part 60, appendix A. Each potential leak interface (i.e., a location where organic...
Carlton, Matthew; Campbell, John
2013-11-01
Membrane oxygenator heat exchanger (HE) device failure is reported to be very low for both short- and long-term extracorporeal devices. All oxygenator manufacturers provide instructions for leak testing of their HE devices prior to patient use. In addition to these recommendations, since 2006 at Nottingham University Hospitals (NUH) we have also additionally pressure tested HE devices prior to use. We conducted a national survey of cardiac centers in Great Britain and Ireland to determine the methods undertaken in individual centers for validation of the integrity of HE devices. Furthermore, we also collected information on the routine maintenance techniques utilized within these centers to inhibit microbial growth in the water used in the heater-cooler units (HCUs). In total, 34 responses were collected from the 57 centers performing cardiac surgery, producing a response rate of 60%. Of the responding centers, 71% are adhering to manufacturer's recommended guidelines of circulating the water through the device for 5 minutes. Of these centers, 17% reported detecting a leak between the HE and membrane compartment of the oxygenator. In responding centers, 29% reported using the pressure test technique. In the centers utilizing pressure testing, 60% reported detecting a leak. This survey reports an association of a greater HE leak detection rate using the pressure test technique compared to using water testing in isolation (p = 0.034). We believe the pressure testing method provides the perfusionist with confidence in the integrity of the HE for short- and long-term circulatory support devices prior to use in both elective and emergency situations.
NASA Technical Reports Server (NTRS)
Russell, John M.
1993-01-01
Many helium mass spectrometer leak detectors at KSC employ sampling systems that feature hand held sniffer probes. Authors of general leakage-testing literature recommend sniffer probes for leak location but not for quantitative leakage measurement. Their use in the latter application at KSC involves assumptions that may be subtle. The purpose of the research effort reported herein was to establish the significance of indicated leak rates displayed by sniffer-probe equipped leak detectors and to determine whether the use of alternative hardware or testing procedures may reduce the uncertainty of leakage measurements made with them. The report classifies probe-type sampling systems for helium leak detectors according to their internal plumbing (direct or branched), presents a basic analysis of the fluid dynamics in the sampling system in the branched-conduit case, describes the usual test method for measuring the internal supply-to-sample flowrate ratio (a.k.a permeation ratio), and describes a concept for a sponge-tipped probe whose external supply-to-sample flowrate ratio promises to be lower than that of a simple-ended probe. One conclusion is that the main source of uncertainty in the use of probe-type sampling systems for leakage measurement is uncertainty in the external supply-to-sample flowrate ratio. In contrast, the present method for measuring the internal supply-to-sample flowrate ratio is quantitative and satisfactory. The implication is that probes of lower external supply-to-sample flowrate ratio must be developed before this uncertainty may be reduced significantly.
Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak.
Dauber, I M; Pluss, W T; VanGrondelle, A; Trow, R S; Weil, J V
1985-08-01
Noninvasive techniques employing external counting of radiolabeled protein have the potential for measuring pulmonary vascular protein permeability, but their specificity and sensitivity remain unclear. We tested the specificity and sensitivity of a double-radioisotope method by injecting radiolabeled albumin (131I) and erythrocytes (99mTc) into anesthetized dogs and measuring the counts of each isotope for 150 min after injection with an external gamma probe fixed over the lung. We calculated the rate of increase of albumin counts measured by the probe (which reflects the rate at which protein leaks into the extravascular space). To assess permeability we normalized the rate of increase in albumin counts for changes in labeled erythrocyte signal to minimize influence of changes in vascular surface area and thus derived an albumin leak index. We measured the albumin leak index and gravimetric lung water during hydrostatic edema (acutely elevating left atrial pressure by left atrial balloon inflation: mean pulmonary arterial wedge pressure = 22.6 Torr) and in lung injury edema induced by high- (1.0 g/kg) and low-dose (0.25 g/kg) intravenous thiourea. To test specificity we compared hydrostatic and high-dose thiourea edema. The albumin leak index increased nearly fourfold from control after thiourea injury (27.2 +/- 2.3 X 10-4 vs. 7.6 +/- 0.9 X 10-4 min-1) but did not change from control levels after elevating left atrial pressure (8.9 +/- 1.2 X 10-4 min-1) despite comparable increases in gravimetric lung water. To test sensitivity we compared low-dose thiourea with controls. Following low-dose thiourea, the albumin leak index nearly doubled despite the absence of a measurable increase in lung water. We conclude that a noninvasive double radioisotope measurement of pulmonary vascular protein leak, employing external counting techniques and a simplified method of calculation, is specific for lung injury and is also sensitive enough to detect lung injury insufficient to produce detectable pulmonary edema.
Phalen, Robert N.; Wong, Weng kee
2012-01-01
Background: The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. Objectives: This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Methods: Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Results: Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm−2 were about four times less likely to leak. Conclusions: On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break. PMID:22201179
Hardwick, Lisa M; Nail, Steven L; Jarman, James; Hasler, Kai; Hense, Thomas
2013-10-01
A scientific rationale is proposed for the establishment of acceptance criteria for leak rates in pharmaceutical freeze dryers. A method was developed to determine the quantity of air that could leak into any lyophilizer from the outside while still maintaining Class 100/Grade A microbial conditions. A lyophilizing product is assumed most vulnerable to microbial contamination during secondary drying, when mass transfer of water vapor from product to condenser is minimal. Using the void volume of the dryer, calculated from change in internal pressure when a known volume of air is introduced, and the potential maximum bioburden of the leaked air (based on measured values), calculations can determine the allowable leaked volume of air, the flow rate required to admit that volume in a given time frame, and the pressure rise that would result from the leak over a given testing period. For the dryers in this study, using worst-case air quality conditions, it was determined that a leak resulting in a pressure rise of 0.027 mbar over a 30 min period would allow the dryers to remain in secondary drying conditions for 62 h before the established action level of one colony forming unit for each cubic meter of air space would be reached. Copyright © 2013 Elsevier B.V. All rights reserved.
Kanaji, Shingo; Ohyama, Masato; Yasuda, Takashi; Sendo, Hiroyoshi; Suzuki, Satoshi; Kawasaki, Kentaro; Tanaka, Kenichi; Fujino, Yasuhiro; Tominaga, Masahiro; Kakeji, Yoshihiro
2016-07-01
Anastomotic failures that cannot be detected during surgery often lead to postoperative leakage. There have been no detailed reports on the intraoperative leak test for esophagojejunal anastomosis. Our purpose was to investigate the utility of routine intraoperative leak testing to prevent postoperative anastomotic leakage after performing esophagojejunostomy. We prospectively performed routine air leak tests and reviewed the records of 185 consecutive patients with gastric cancer who underwent open total gastrectomy followed by esophagojejunostomy. A positive leak test was found for six patients (3.2 %). These patients with positive leak tests were subsequently treated with additional suturing, and they developed no postoperative anastomotic leakage. However, anastomotic leakage occurred in nine patients (4.9 %) with negative leak tests. A multivariate analysis demonstrated that a patient age >75 years and the surgeon's experience <30 cases were risk factors for anastomotic leakage. Intraoperative leak testing can detect some physical dehiscence, and additional suturing may prevent anastomotic leakage. However, it cannot prevent all anastomotic leakage caused by other factors, such as the surgeons' experience and patients' age.
NASA Astrophysics Data System (ADS)
Alden, C. B.; Coburn, S.; Wright, R.; Baumann, E.; Cossel, K.; Sweeney, C.; Ghosh, S.; Newbury, N.; Prasad, K.; Coddington, I.; Rieker, G. B.
2017-12-01
Advances in natural gas extraction technology have led to increased US production and transport activity, and as a consequence, an increased need for monitoring of methane leaks. Current leak detection methods provide time snapshots, and not continuous, time-varying estimates of emissions. Most approaches also require specific atmospheric conditions, operators, or the use of a tracer gas, requiring site access. Given known intermittency in fugitive methane emissions, continuous monitoring is a critical need for emissions mitigation. We present a novel leak detection method that employs dual frequency comb spectrometry to offer continuous, autonomous, leak detection and quantification over square-km scale areas. The spectrometer is situated in a field of natural gas pads, and a series of retroreflectors around the field direct light back to a detector. The laser light spans 1620-1680 nm with 0.002 nm line spacing, measuring thousands of individual absorption features from multiple species. The result is high-stability trace gas (here CH4, CO2, and H2O) measurements over long (1 km+) open paths through the atmosphere. Measurements are used in an atmospheric inversion to estimate the time variability of emissions at each location of interest. Importantly, the measurement framework and inversion solve explicitly for background concentrations, which vary rapidly in fields of active oil and gas production. We present the results of controlled-leak field tests in rural Colorado. We demonstrate the ability to locate and size a leak located 1 km away from the spectrometer and varying in strength from 1.5 to 7.7 g/min, resulting in mean atmospheric enhancements of 20 ppb. The inversion correctly identifies when the leak turned on and off over a 24-hour period, and determines the mean leak strength to within 10% of the true controlled rate. We further demonstrate the ability of the system to correctly locate and size the start and end of simultaneous 2.7 to 4.8 g/min leaks from 2 sources in a field of 5 potential leak locations. Finally, we present the results of leak-detection tests in active oil and gas fields in the Denver Julesburg Basin, where background methane is complex.
Cooper, C.M.
1961-01-01
A method and apparatus for determining whether the jacket of a nuclear- fuel slug has a leak are described. The region of the jacket to be leak-tested is sealed off, and gas under pressure is applied thereto. If there is an imperfection, the gas will enter the jacket and bulge another region of the jacket. The bulge occurring is measured by a gage.
Duct Leakage Repeatability Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain; Sherman, Max
2014-08-01
The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less
Leak testing and repair of fusion devices
NASA Astrophysics Data System (ADS)
Kozman, T. A.
1983-06-01
The leak testing, reporting and vacuum leak repair techniques of the MPTF yin-yang number one magnet system, the world's largest superconducting magnet system, are discussed. Based on this experience, techniques are developed for testing and repairing leaks on the 42 MPTF-B magnets. The leak hunting techniques for the yin-yang magnet systems were applied to two helium circuits (the coil bundle and guard vacuum; both require helium flow for magnet cooldown). Additionally, during MPTF-B operation there are warm water plasma shields and piping that require leak checking.
40 CFR 53.52 - Leak check test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...
40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B
Code of Federal Regulations, 2013 CFR
2013-07-01
...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 8 2013-07-01 2013-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...
40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B
Code of Federal Regulations, 2014 CFR
2014-07-01
...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 8 2014-07-01 2014-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...
40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B
Code of Federal Regulations, 2011 CFR
2011-07-01
...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 7 2011-07-01 2011-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...
40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B
Code of Federal Regulations, 2012 CFR
2012-07-01
...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 8 2012-07-01 2012-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...
LOCATION OF LEAKS IN PRESSURIZED PETROLEUM PIPELINES BY MEANS OF PASSIVE-ACOUSTIC METHODS
Experiments were conducted on the underground pipeline at the EPA's UST Test Apparatus n which three acoustic sensors separated by a maximum distance of 38m (125 ft) were used to monitor signals produced by 11.4-, 5.7-, and 3.8-L/h (3.0-, 1.5-, and 1.0-gal/h) leaks in the wall of...
10 CFR 35.2067 - Records of leaks tests and inventory of sealed sources and brachytherapy sources.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Records of leaks tests and inventory of sealed sources and... MATERIAL Records § 35.2067 Records of leaks tests and inventory of sealed sources and brachytherapy sources. (a) A licensee shall retain records of leak tests required by § 35.67(b) for 3 years. The records...
40 CFR 53.52 - Leak check test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...
40 CFR 53.52 - Leak check test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...
40 CFR 53.52 - Leak check test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
Routine intraoperative leak testing for sleeve gastrectomy: is the leak test full of hot air?
Bingham, Jason; Lallemand, Michael; Barron, Morgan; Kuckelman, John; Carter, Preston; Blair, Kelly; Martin, Matthew
2016-05-01
Staple line leak after sleeve gastrectomy (SG) is a rare but dreaded complication with a reported incidence of 0% to 8%. Many surgeons routinely test the staple line with an intraoperative leak test (IOLT), but there is little evidence to validate this practice. In fact, there is a theoretical concern that the leak test may weaken the staple line and increase the risk of a postop leak. Retrospective review of all SGs performed over a 7-year period was conducted. Cases were grouped by whether an IOLT was performed, and compared for the incidence of postop staple line leaks. The ability of the IOLT for identifying a staple line defect and for predicting a postoperative leak was analyzed. Five hundred forty-two SGs were performed between 2007 and 2014. Thirteen patients (2.4%) developed a postop staple line leak. The majority of patients (n = 494, 91%) received an IOLT, including all 13 patients (100%) who developed a subsequent clinical leak. There were no (0%) positive IOLTs and no additional interventions were performed based on the IOLT. The IOLT sensitivity and positive predictive value were both 0%. There was a trend, although not significant, to increase leak rates when a routine IOLT was performed vs no routine IOLT (2.6% vs 0%, P = .6). The performance of routine IOLT after SG provided no actionable information, and was negative in all patients who developed a postoperative leak. The routine use of an IOLT did not reduce the incidence of postop leak, and in fact was associated with a higher leak rate after SG. Published by Elsevier Inc.
He, Guoxi; Liang, Yongtu; Li, Yansong; Wu, Mengyu; Sun, Liying; Xie, Cheng; Li, Feng
2017-06-15
The accidental leakage of long-distance pressurized oil pipelines is a major area of risk, capable of causing extensive damage to human health and environment. However, the complexity of the leaking process, with its complex boundary conditions, leads to difficulty in calculating the leakage volume. In this study, the leaking process is divided into 4 stages based on the strength of transient pressure. 3 models are established to calculate the leaking flowrate and volume. First, a negative pressure wave propagation attenuation model is applied to calculate the sizes of orifices. Second, a transient oil leaking model, consisting of continuity, momentum conservation, energy conservation and orifice flow equations, is built to calculate the leakage volume. Third, a steady-state oil leaking model is employed to calculate the leakage after valves and pumps shut down. Moreover, sensitive factors that affect the leak coefficient of orifices and volume are analyzed respectively to determine the most influential one. To validate the numerical simulation, two types of leakage test with different sizes of leakage holes were conducted from Sinopec product pipelines. More validations were carried out by applying commercial software to supplement the experimental insufficiency. Thus, the leaking process under different leaking conditions are described and analyzed. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Tian, Jialin; Madaras, Eric I.
2009-01-01
The development of a robust and efficient leak detection and localization system within a space station environment presents a unique challenge. A plausible approach includes the implementation of an acoustic sensor network system that can successfully detect the presence of a leak and determine the location of the leak source. Traditional acoustic detection and localization schemes rely on the phase and amplitude information collected by the sensor array system. Furthermore, the acoustic source signals are assumed to be airborne and far-field. Likewise, there are similar applications in sonar. In solids, there are specialized methods for locating events that are used in geology and in acoustic emission testing that involve sensor arrays and depend on a discernable phase front to the received signal. These methods are ineffective if applied to a sensor detection system within the space station environment. In the case of acoustic signal location, there are significant baffling and structural impediments to the sound path and the source could be in the near-field of a sensor in this particular setting.
Assessing surgeon behavior change after anastomotic leak in colorectal surgery.
Simianu, Vlad V; Basu, Anirban; Alfonso-Cristancho, Rafael; Thirlby, Richard C; Flaxman, Abraham D; Flum, David R
2016-10-01
Recency effect suggests that people disproportionately value events from the immediate past when making decisions, but the extent of this impact on surgeons' decisions is unknown. This study evaluates for recency effect in surgeons by examining use of preventative leak testing before and after colorectal operations with anastomotic leaks. Prospective cohort of adult patients (≥18 y) undergoing elective colorectal operations at Washington State hospitals participating in the Surgical Care and Outcomes Assessment Program (2006-2013). The main outcome measure was surgeons' change in leak testing from 6 mo before to 6 mo after an anastomotic leak occurred. Across 4854 elective colorectal operations performed by 282 surgeons at 44 hospitals, there was a leak rate of 2.6% (n = 124). The 40 leaks (32%) in which the anastomosis was not tested occurred across 25 surgeons. While the ability to detect an overall difference in use of leak testing was limited by small sample size, nine (36%) of 25 surgeons increased their leak testing by 5% points or more after leaks in cases where the anastomosis was not tested. Surgeons who increased their leak testing more frequently performed operations for diverticulitis (45% versus 33%), more frequently began their cases laparoscopically (65% versus 37%), and had longer mean operative times (195 ± 99 versus 148 ± 87 min), all P < 0.001. Recency effect was demonstrated by only one-third of eligible surgeons. Understanding the extent to which clinical decisions may be influenced by recency effect may be important in crafting quality improvement initiatives that require clinician behavior change. Copyright © 2016 Elsevier Inc. All rights reserved.
Lymphangiography in the Diagnosis and Localization of Various Chyle Leaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deso, Steve; Ludwig, Benjamin; Kabutey, Nii-Kabu
2012-02-15
Purpose: Chyle leaks are rare entities infrequently encountered by most physicians. However, large centers providing advanced surgical care are inevitably confronted with chyle leaks as a complication of surgery, an extension of disease, or as a primary disorder. Regardless of the etiology, proper diagnosis and localization are paramount in the management of any chyle leak. Materials and Methods: Here we present 16 patients with 17 chyle leaks (5 chyluria, 8 chylothorax, and 4 chylous ascites) who underwent bipedal lymphangiography (LAG) and postprocedure computed tomography (CT) imaging. Results: In each case, the source of the chyle leak was identified and properlymore » localized to guide further treatment. Of the 16 patients who underwent LAG and postprocedure CT imaging, the initial LAG alone provided the diagnosis and localized the chyle leak in 4 patients (25%); the postprocedure CT imaging provided the diagnosis and localized the chyle leak in 6 patients (37.5%); and the two modalities were equal in the diagnosing and localizing the chyle leak in the remaining 6 patients (37.5%)ConclusionThese cases highlight the unparalleled abilities of LAG and the added benefit of post-LAG CT imaging in the diagnosis and fine anatomic localization of chyle leaks. In addition, these cases demonstrate the retained utility of LAG in these investigations despite the development of alternative tests involving CT, magnetic resonance imaging, and nuclear medicine imaging.« less
Technical factors associated with anastomotic leak after Roux-en-Y gastric bypass.
Smith, Mark D; Adeniji, Abidemi; Wahed, Abdus S; Patterson, Emma; Chapman, William; Courcoulas, Anita P; Dakin, Gregory; Flum, David; McCloskey, Carol; Mitchell, James E; Pomp, Alfons; Staten, Myrlene; Wolfe, Bruce
2015-01-01
Anastomotic leak is one of the most serious complications after Roux-en-Y gastric bypass (RYGB). Our objective was to examine the relationship between technical factors and incidence of clinically relevant anastomotic leak after RYGB in longitudinal assessment of bariatric surgery (LABS). The setting of the study was 11 bariatric centers in the United States, university, and private practice. Patient characteristics, technical factors of surgery, and postoperative outcomes were assessed by trained researchers using standardized protocols. Correlation of surgical factors of patients undergoing RYGB (n = 4444) with the incidence of postoperative anastomotic leak was assessed by univariate χ(2) analysis. Forty-four participants (1.0%, 95% CI .7%-1.3%) experienced a clinically relevant anastomotic leak. Of these, 39 (89%) underwent abdominal reoperation and 3 (7%) died. Technical factors associated with anastomotic leak were open surgery (P<.0001), revision surgery (P<.0001), and use of an abdominal drain (P = .02). Provocative leak testing, method of gastrojejunostomy, and use of fibrin sealant were not associated with anastomotic leak. Anastomotic leak after RYGB was rare (1.0%). Most cases required reintervention; however, the majority (93%) recovered from this event. Open surgery, revision surgery, and routine drain placement were associated with increased leak rate. Some of these findings may be due to differences in preoperative patient risk. Copyright © 2015 American Society for Metabolic and Bariatric Surgery. All rights reserved.
Examinations for leak tightness of actively cooled components in ITER and fusion devices
NASA Astrophysics Data System (ADS)
Hirai, T.; Barabash, V.; Carrat, R.; Chappuis, Ph; Durocher, A.; Escourbiac, F.; Merola, M.; Raffray, R.; Worth, L.; Boscary, J.; Chantant, M.; Chuilon, B.; Guilhem, D.; Hatchressian, J.-C.; Hong, S. H.; Kim, K. M.; Masuzaki, S.; Mogaki, K.; Nicolai, D.; Wilson, D.; Yao, D.
2017-12-01
Any leak in one of the ITER actively cooled components would cause significant consequences for machine operations; therefore, the risk of leak must be minimized as much as possible. In this paper, the strategy of examination to ensure leak tightness of the ITER internal components (i.e. examination of base materials, vacuum boundary joints and final components) and the hydraulic parameters for ITER internal components are summarized. The experiences of component tests, especially hot helium leak tests in recent fusion devices, were reviewed and the parameters were discussed. Through these experiences, it was confirmed that the hot He leak test was effective to detect small leak paths which were not always possible to detect by volumetric examination due to limited spatial resolution.
Terterov, Dimitry; Leung, Philemon Ho-Yan; Twells, Laurie K.; Gregory, Deborah M.; Smith, Chris; Boone, Darrell; Pace, David
2017-01-01
Background Although laparoscopic sleeve gastrectomy (LSG) has been shown to be a safe and effective treatment for severe obesity (body mass index ≥ 35), staple line leaks remain a major complication and account for a substantial portion of the procedure’s morbidity and mortality. Many centres performing LSG routinely obtain contrast studies on postoperative day 1 for early detection of staple line leaks. We examined the usefulness of Gastrografin swallow as an early detection test for staple line leaks on postoperative day 1 after LSG as well as the associated costs. Methods We conducted a retrospective review of a prospectively collected database that included 200 patients who underwent LSG for severe obesity between 2011 and 2014. Primary outcome measures were the incidence of staple line leaks and the results of Gastrografin swallow tests. We obtained imaging costs from appropriate hospital departments. Results Gastrografin swallow was obtained on postoperative day 1 for all 200 patients who underwent LSG. Three patients (1.5%) were found to have staple line leaks. Gastrograffin swallows yielded 1 true positive result and 2 false negatives. The false negatives were subsequently diagnosed on computed tomography (CT) scan. The sensitivity of Gastrografin swallow in this study was 33%. For 200 patients, the total direct cost of the Gastrografin swallows was $35 000. Conclusion The use of routine upper gastrointestinal contrast studies for early detection of staple line leaks has low sensitivity and is costly. We recommend selective use of CT instead. PMID:28742012
Prediction of failure pressure and leak rate of stress corrosion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majumdar, S.; Kasza, K.; Park, J. Y.
2002-06-24
An ''equivalent rectangular crack'' approach was employed to predict rupture pressures and leak rates through laboratory generated stress corrosion cracks and steam generator tubes removed from the McGuire Nuclear Station. Specimen flaws were sized by post-test fractography in addition to a pre-test advanced eddy current technique. The predicted and observed test data on rupture and leak rate are compared. In general, the test failure pressures and leak rates are closer to those predicted on the basis of fractography than on nondestructive evaluation (NDE). However, the predictions based on NDE results are encouraging, particularly because they have the potential to determinemore » a more detailed geometry of ligamented cracks, from which failure pressure and leak rate can be more accurately predicted. One test specimen displayed a time-dependent increase of leak rate under constant pressure.« less
Apparatus for Testing Flat Specimens of Thermal Insulation
NASA Technical Reports Server (NTRS)
Fesmire, James E.; Augustynowicz, Stanislaw D.
2005-01-01
An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.
Kirsch, L E; Nguyen, L; Moeckly, C S
1997-01-01
The development of mass spectrometry-based leak detection for pharmaceutical container integrity was undertaken to provide an alternative to microbial challenge testing. Standard 10-mL vials were modified to contain pinholes (0.5 to 10 microns) by affixing micropipettes with epoxy into 2-mm vial side wall holes. The absolute leak rate was determined using vials that were sealed in a tracer (helium) environment with butyl rubber stoppers and crimps. Alternatively leak rates were determined using vials that were sealed in room air and exposed to tracer under pressure (charging or bombing). Tracer leak rates were measured with mass spectrometry leak rate detectors. The absolute leak rate was correlated the squared nominal leak radius which suggested that the mode of gas flow through the glass pipette leaks was more turbulent than viscous even at low leak rates typically associated with viscous flow. The minimum observed absolute leak rate was about 10(-6.6) std cc/sec and was likely due to helium permeation through the rubber stoppers. Heat-stressed rubber stoppers did not affect the baseline absolute leak rate. Adsorption of helium tracer to the test unit surfaces was found to confound baseline leak rate measurement reliability but was eliminated as a source of variation by exposing the test units to ambient air for > or = 12 hours. The absolute leak rate and the leak rate measured after charging were related in a mathematically predictable way.
Routine Leak Testing in Colorectal Surgery in the Surgical Care and Outcomes Assessment Program
Kwon, Steve; Morris, Arden; Billingham, Richard; Frankhouse, Joseph; Horvath, Karen; Johnson, Morrie; McNevin, Shane; Simons, Anthony; Symons, Rebecca; Steele, Scott; Thirlby, Richard; Whiteford, Mark; Flum, David R.
2014-01-01
Objective To evaluate the effect of routine anastomotic leak testing (performed to screen for leaks) vs selective testing (performed to evaluate for a suspected leak in a higher-risk or technically difficult anastomosis) on outcomes in colorectal surgery because the value of provocative testing of colorectal anastomoses as a quality improvement metric has yet to be determined. Design Observational, prospectively designed cohort study. Setting Data from Washington state’s Surgical Care and Outcomes Assessment Program (SCOAP). Patients Patients undergoing elective left-sided colon or rectal resections at 40 SCOAP hospitals from October 1, 2005, to December 31, 2009. Interventions Use of leak testing, distinguishing procedures that were performed at hospitals where leak testing was selective (<90% use) or routine (≥90% use) in a given calendar quarter. Main Outcome Measure Adjusted odds ratio of a composite adverse event (CAE) (unplanned postoperative intervention and/or in-hospital death) at routine testing hospitals. Results Among 3449 patients (mean [SD] age, 58.8[14.8] years; 55.0% women), the CAE rate was 5.5%. Provocative leak testing increased (from 56% in the starting quarter to 76% in quarter 16) and overall rates of CAE decreased (from 7.0% in the starting quarter to 4.6% in quarter 16; both P ≤ .01) over time. Among patients at hospitals that performed routine leak testing, we found a reduction of more than 75% in the adjusted risk of CAEs (odds ratio, 0.23; 95% CI, 0.05–0.99). Conclusion Routine leak testing of left-sided colorectal anastomoses appears to be associated with a reduced rate of CAEs within the SCOAP network and meets many of the criteria of a worthwhile quality improvement metric. PMID:22508778
Routine leak testing in colorectal surgery in the Surgical Care and Outcomes Assessment Program.
Kwon, Steve; Morris, Arden; Billingham, Richard; Frankhouse, Joseph; Horvath, Karen; Johnson, Morrie; McNevin, Shane; Simons, Anthony; Symons, Rebecca; Steele, Scott; Thirlby, Richard; Whiteford, Mark; Flum, David R
2012-04-01
To evaluate the effect of routine anastomotic leak testing (performed to screen for leaks) vs selective testing (performed to evaluate for a suspected leak in a higher-risk or technically difficult anastomosis) on outcomes in colorectal surgery because the value of provocative testing of colorectal anastomoses as a quality improvement metric has yet to be determined. Observational, prospectively designed cohort study. Data from Washington state's Surgical Care and Outcomes Assessment Program (SCOAP). Patients undergoing elective left-sided colon or rectal resections at 40 SCOAP hospitals from October 1, 2005, to December 31, 2009. Use of leak testing, distinguishing procedures that were performed at hospitals where leak testing was selective (<90% use) or routine (≥ 90% use) in a given calendar quarter. Adjusted odds ratio of a composite adverse event (CAE) (unplanned postoperative intervention and/or in-hospital death) at routine testing hospitals. Among 3449 patients (mean [SD] age, 58.8 [14.8] years; 55.0% women), the CAE rate was 5.5%. Provocative leak testing increased (from 56% in the starting quarter to 76% in quarter 16) and overall rates of CAE decreased (from 7.0% in the starting quarter to 4.6% in quarter 16; both P ≤ .01) over time. Among patients at hospitals that performed routine leak testing, we found a reduction of more than 75% in the adjusted risk of CAEs (odds ratio, 0.23; 95% CI, 0.05-0.99). Routine leak testing of left-sided colorectal anastomoses appears to be associated with a reduced rate of CAEs within the SCOAP network and meets many of the criteria of a worthwhile quality improvement metric.
Study of Residual Gas Analyser (RGA) Response towards Known Leaks
NASA Astrophysics Data System (ADS)
Pathan, Firozkhan S.; Khan, Ziauddin; Semwal, Pratibha; George, Siju; Raval, Dilip C.; Thankey, Prashant L.; Manthena, Himabindu; Yuvakiran, Paravastu; Dhanani, Kalpesh R.
2012-11-01
Helium leak testing is the most versatile form of weld qualification test for any vacuum application. Almost every ultra-high vacuum (UHV) system utilizes this technique for insuring leak tightness for the weld joints as well as demountable joints. During UHV system under operational condition with many other integrated components, in-situ developed leaks identification becomes one of the prime aspect for maintaining the health of such system and for continuing the experiments onwards. Since online utilization of leak detector (LD) has many practical limitations, residual gas analyser (RGA) can be used as a potential instrument for online leak detection. For this purpose, a co-relation for a given leak rate between Leak Detector and RGA is experimentally established. This paper describes the experimental aspect and the relationship between leak detector and RGA.
Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.
Rimstad, Liv; Larsen, Elsa Skjønhaug; Schiøtz, Hjalmar A; Kulseng-Hanssen, Sigurd
2014-09-01
The aim of the study was to test the ability of pad stress tests with increasing load (supine, jumping on the floor, and jumping on a trampoline) to document stress incontinence in subjectively stress incontinent women. In this prospective study 147 subjectively stress and mixed incontinent women performed consecutively the three pad stress tests with a bladder volume of 300 ml. Nineteen women performed a second trampoline pad stress test to test repeatability of the test. Nine continent women performed a trampoline pad stress test in order to determine if subjectively continent women would leak during the test. Seventy-two women (49%) leaked during the supine, 136 (93%) leaked during the jumping, and 146 (99%) leaked during the trampoline pad stress test. The differences between pad stress tests were significant with P < 0.005. Correlation between the two trampoline pad stress tests was high at 0.8. None of the nine continent women leaked during the trampoline pad stress test. The supine pad stress test has low sensitivity and is therefore often falsely negative. The jumping pad stress test is a simple test to perform and is satisfactory for everyday use. Subjectively stress incontinent women who do not leak during the jumping pad stress test may perform a trampoline pad stress test to document stress incontinence. The trampoline pad stress test is also simple to perform and detected leakage in 91% of the women who did not leak during the jumping pad stress test. © 2013 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... degrees Fahrenheit ([deg]F) as a consequence of inservice leak and hydrostatic testing, and as a consequence of scram time testing initiated in conjunction with an inservice leak or hydrostatic test, while... [Limited Conditions of Operation] 3.10.1, Inservice Leak and Hydrostatic Testing Operation Using...
Intraoperatively Testing the Anastomotic Integrity of Esophagojejunostomy Using Methylene Blue.
Celik, S; Almalı, N; Aras, A; Yılmaz, Ö; Kızıltan, R
2017-03-01
Intraoperative testing of gastrointestinal anastomosis effectively ensures anastomotic integrity. This study investigated whether the routine use of methylene blue intraoperatively identified leaks to reduce the postoperative proportion of clinical leaks. This study retrospectively analyzed consecutive total gastrectomies performed from January 2007 to December 2014 in a university hospital setting by a general surgical group that exclusively used the methylene blue test. All surgeries were performed for gastric or junctional cancers (n = 198). All reconstructions (Roux-en Y esophagojejunostomy) were performed using a stapler. The methylene blue test was used in 108 cases (group 1) via a nasojejunal tube. No test was performed for the other 90 cases (group 2). Intraoperative leakage rate, postoperative clinical leakage rate, length of hospitalization, and mortality rate were the outcome measures. The intraoperative leakage rate was 7.4% in group 1. The postoperative clinical leakage rate was 8.6%. The postoperative clinical leakage rate was 3.7% in group 1 and 14.4% in group 2 (p = 0.007). There were no postoperative clinical leaks when an intraoperative leak led to concomitant intraoperative repair. The median length of hospital stay was 6 days in group 1 and 8 days in group 2 (p < 0.001). One death occurred in each group. No test-related complications were observed. The methylene blue test for esophagojejunostomy is a safe and reliable method for the assessment of anastomosis integrity, especially in cases with difficult esophagojejunostomic construction.
Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram
NASA Astrophysics Data System (ADS)
Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.
2015-10-01
Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.
Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2015-01-01
The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.
Leakage detection in galvanized iron pipelines using ensemble empirical mode decomposition analysis
NASA Astrophysics Data System (ADS)
Amin, Makeen; Ghazali, M. Fairusham
2015-05-01
There are many numbers of possible approaches to detect leaks. Some leaks are simply noticeable when the liquids or water appears on the surface. However many leaks do not find their way to the surface and the existence has to be check by analysis of fluid flow in the pipeline. The first step is to determine the approximate position of leak. This can be done by isolate the sections of the mains in turn and noting which section causes a drop in the flow. Next approach is by using sensor to locate leaks. This approach are involves strain gauge pressure transducers and piezoelectric sensor. the occurrence of leaks and know its exact location in the pipeline by using specific method which are Acoustic leak detection method and transient method. The objective is to utilize the signal processing technique in order to analyse leaking in the pipeline. With this, an EEMD method will be applied as the analysis method to collect and analyse the data.
Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection.
Davidson, Tsetsegdemberel Bat-Ulzii; Yaghoobi, Mohammad; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2017-04-07
The treatment of people with clinically significant postoperative pancreatic leaks is different from those without clinically significant pancreatic leaks. It is important to know the diagnostic accuracy of drain fluid amylase as a triage test for the detection of clinically significant pancreatic leaks, so that an informed decision can be made as to whether the patient with a suspected pancreatic leak needs further investigations and treatment. There is currently no systematic review of the diagnostic test accuracy of drain fluid amylase for the diagnosis of clinically relevant pancreatic leak. To determine the diagnostic accuracy of amylase in drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection. We searched MEDLINE, Embase, the Science Citation Index Expanded, and the National Institute for Health Research Health Technology Assessment (NIHR HTA) websites up to 20 February 2017. We searched the references of the included studies to identify additional studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We also performed a 'related search' and 'citing reference' search in MEDLINE and Embase. We included all studies that evaluated the diagnostic test accuracy of amylase in the drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection excluding total pancreatectomy. We planned to exclude case-control studies because these studies are prone to bias, but did not find any. At least two authors independently searched and screened the references produced by the search to identify relevant studies. Two review authors independently extracted data from the included studies. The included studies reported drain fluid amylase on different postoperative days and measured at different cut-off levels, so it was not possible to perform a meta-analysis using the bivariate model as planned. We have reported the sensitivity, specificity, post-test probability of a positive and negative drain fluid amylase along with 95% confidence interval (CI) on each of the different postoperative days and measured at different cut-off levels. A total of five studies including 868 participants met the inclusion criteria for this review. The five studies included in this review reported the value of drain fluid amylase at different thresholds and different postoperative days. The sensitivities and specificities were variable; the sensitivities ranged between 0.72 and 1.00 while the specificities ranged between 0.73 and 0.99 for different thresholds on different postoperative days. At the median prevalence (pre-test probability) of 15.9%, the post-test probabilities for pancreatic leak ranged between 35.9% and 95.4% for a positive drain fluid amylase test and ranged between 0% and 5.5% for a negative drain fluid amylase test.None of the studies used the reference standard of confirmation by surgery or by a combination of surgery and clinical follow-up, but used the International Study Group on Pancreatic Fistula (ISGPF) grade B and C as the reference standard. The overall methodological quality was unclear or high in all the studies. Because of the paucity of data and methodological deficiencies in the studies, we are uncertain whether drain fluid amylase should be used as a method for testing for pancreatic leak in an unselected population after pancreatic resection; and we judge that the optimal cut-off of drain fluid amylase for making the diagnosis of pancreatic leak is also not clear. Further well-designed diagnostic test accuracy studies with pre-specified index test threshold of drain fluid amylase (at three times more on postoperative day 5 or another suitable pre-specified threshold), appropriate follow-up (for at least six to eight weeks to ensure that there are no pancreatic leaks), and clearly defined reference standards (of surgical, clinical, and radiological confirmation of pancreatic leak) are important to reliably determine the diagnostic accuracy of drain fluid amylase in the diagnosis of pancreatic leak.
40 CFR 53.52 - Leak check test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... be verified at the highest and lowest pressures and temperatures used in the tests and shall be... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Leak check test. 53.52 Section 53.52... Leak check test. (a) Overview. In section 7.4.6 of 40 CFR part 50, appendix L, the sampler is required...
10 CFR 34.27 - Leak testing and replacement of sealed sources.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Leak testing and replacement of sealed sources. 34.27 Section 34.27 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and replacement...
10 CFR 34.27 - Leak testing and replacement of sealed sources.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Leak testing and replacement of sealed sources. 34.27 Section 34.27 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and replacement...
10 CFR 34.27 - Leak testing and replacement of sealed sources.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Leak testing and replacement of sealed sources. 34.27 Section 34.27 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and replacement...
10 CFR 34.27 - Leak testing and replacement of sealed sources.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Leak testing and replacement of sealed sources. 34.27 Section 34.27 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and replacement...
10 CFR 34.27 - Leak testing and replacement of sealed sources.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Leak testing and replacement of sealed sources. 34.27 Section 34.27 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and replacement...
Hermetic Seal Leak Detection Apparatus
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2013-01-01
The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.
Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R
1997-01-01
Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.
High sensitivity leak detection method and apparatus
Myneni, Ganapatic R.
1994-01-01
An improved leak detection method is provided that utilizes the cyclic adsorption and desorption of accumulated helium on a non-porous metallic surface. The method provides reliable leak detection at superfluid helium temperatures. The zero drift that is associated with residual gas analyzers in common leak detectors is virtually eliminated by utilizing a time integration technique. The sensitivity of the apparatus of this disclosure is capable of detecting leaks as small as 1.times.10.sup.-18 atm cc sec.sup.-1.
High sensitivity leak detection method and apparatus
Myneni, G.R.
1994-09-06
An improved leak detection method is provided that utilizes the cyclic adsorption and desorption of accumulated helium on a non-porous metallic surface. The method provides reliable leak detection at superfluid helium temperatures. The zero drift that is associated with residual gas analyzers in common leak detectors is virtually eliminated by utilizing a time integration technique. The sensitivity of the apparatus of this disclosure is capable of detecting leaks as small as 1 [times] 10[sup [minus]18] atm cc sec[sup [minus]1]. 2 figs.
40 CFR 63.428 - Reporting and recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
...; pressure or vacuum change, mm of water; time period of test; number of leaks found with instrument; and... facility as follows: (1) Annual certification testing performed under § 63.425(e) and railcar bubble leak...)); Annual Certification Test—Internal Vapor Valve (§ 63.425(e)(2)); Leak Detection Test (§ 63.425(f...
A primary standard for the calibration of sniffer test leak devices
NASA Astrophysics Data System (ADS)
Jousten, Karl; Becker, Ute
2009-10-01
Test leaks with a gas flow to atmospheric pressure are often called sniffer test leaks. They are used to calibrate leak detectors for sniffing applications. Sniffer test leaks need calibration against a standard. A primary standard for the calibration of sniffer test leaks with relatively low measurement uncertainties is described. It is assured that the measurement result is traceable to the relevant SI units and that there is a well-known and complete measurement uncertainty budget. The measurement range of the system is from 4 × 10-11 mol s-1 (corresponding to 10-4 Pa l s-1 at 23 °C) to 4 × 10-9 mol s-1 (10-2 Pa l s-1 at 23 °C), which is the most often needed range in industry of around 1 g loss per year of the cooling agent R134a. The temperature where the calibration can be carried out may vary from 18 °C to 30 °C. The flow rate of any test gas not condensing in this temperature range can be measured.
Phalen, Robert N; Wong, Weng Kee
2012-05-01
The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm(-2) were about four times less likely to leak. On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break.
NASA Technical Reports Server (NTRS)
Rinehart, Maegan L.
2011-01-01
The purpose of this activity is to provide the Mechanical Components Test Facility (MCTF) with the capability to obtain electronic leak test and proof pressure data, Payload and Components Real-time Automated Test System (PACRATS) data acquisition software will be utilized to display real-time data. It will record leak rates and pressure/vacuum level(s) simultaneously. This added functionality will provide electronic leak test and pressure data at specified sampling frequencies. Electronically stored data will provide ES61 with increased data security, analysis, and accuracy. The tasks performed in this procedure are to verify PACRATS only, and are not intended to provide verifications for MCTF equipment.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653
Failure Pressure and Leak Rate of Steam Generator Tubes With Stress Corrosion Cracks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majumdar, S.; Kasza, K.; Park, J.Y.
2002-07-01
This paper illustrates the use of an 'equivalent rectangular crack' approach to predict leak rates through laboratory generated stress corrosion cracks. A comparison between predicted and observed test data on rupture and leak rate from laboratory generated stress corrosion cracks are provided. Specimen flaws were sized by post-test fractography in addition to pre-test advanced eddy current technique. The test failure pressures and leak rates are shown to be closer to those predicted on the basis of fractography than on NDE. However, the predictions based on NDE results are encouraging, particularly because they have the potential to determine a more detailedmore » geometry of ligamentous cracks from which more accurate predictions of failure pressure and leak rate can be made in the future. (authors)« less
Development of a leak location system for use on underground electric power transmission cable
NASA Astrophysics Data System (ADS)
Williams, J. A.
1982-10-01
This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000 m long on a feeder that might be 30 km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection and detection scheme was developed for use in areas where the dogs may be unsuitable.
10 CFR 34.67 - Records of leak testing of sealed sources and devices containing depleted uranium.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Records of leak testing of sealed sources and devices containing depleted uranium. 34.67 Section 34.67 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL... Requirements § 34.67 Records of leak testing of sealed sources and devices containing depleted uranium. Each...
10 CFR 34.67 - Records of leak testing of sealed sources and devices containing depleted uranium.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Records of leak testing of sealed sources and devices containing depleted uranium. 34.67 Section 34.67 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL... Requirements § 34.67 Records of leak testing of sealed sources and devices containing depleted uranium. Each...
10 CFR 34.67 - Records of leak testing of sealed sources and devices containing depleted uranium.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Records of leak testing of sealed sources and devices containing depleted uranium. 34.67 Section 34.67 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL... Requirements § 34.67 Records of leak testing of sealed sources and devices containing depleted uranium. Each...
10 CFR 34.67 - Records of leak testing of sealed sources and devices containing depleted uranium.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Records of leak testing of sealed sources and devices containing depleted uranium. 34.67 Section 34.67 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL... Requirements § 34.67 Records of leak testing of sealed sources and devices containing depleted uranium. Each...
The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...
The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...
10 CFR 34.67 - Records of leak testing of sealed sources and devices containing depleted uranium.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Records of leak testing of sealed sources and devices containing depleted uranium. 34.67 Section 34.67 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL... Requirements § 34.67 Records of leak testing of sealed sources and devices containing depleted uranium. Each...
Leakage Through a Channel Formed by a Gasket, a Sealing Surface, and a Filament Trapped Between Them
NASA Technical Reports Server (NTRS)
Russell, John; Adams, Frederick
1996-01-01
Plumbing for the transport of liquid Hydrogen or liquid Oxygen at the Kennedy Space Center (KSC) is very critical. Every piece of hardware for handling such a hazardous cryogen is subject to testing prior to installation and use. Safe, realistic testing of all such hardware is prohibitively expensive, which leads, perforce, to expidients such as: (1) lead testing with non-flammable tracer fluids (e.g, liquid nitrogen) and (2) leak testing with room temperature tracer fluids (e.g. liquid helium). Such expedients undermine the realism of the tests. If however, one could apply rational fluid dynamics methods to derive a general analytical expression with which one could relate the throughput of gaseous Helium through a given leak channel to the throughput of liquid Hydrogen through the same channel, then one could recover much of the information that one would otherwise forfeit through these expedients. These facts lead to the following questions: (1) What would be an example of a generic flaw in a gasket?; and (2) How can one calculate the flow of fluid in it? The report addresses these questions. It considers a particular leak geometry, namely one formed by a gasket, a sealing surface, and a filament trapped between them (so that the cross section of the leak channel is a flat bottomed curvilinear triangle, two sides of which are circular arcs and which has cusps on all three corners).
FY2017 status report: Model 9975 O-ring fixture long-term leak performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially andmore » have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. Leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The 300 °F GLT O-ring fixtures failed after 2.8 to 5.7 years at temperature. The remaining GLT O-ring fixtures aging at 300 ºF were retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 9 to 10.5 years, or in GLT O-ring fixtures aging at 270 ºF for 5.7 years. These aging temperatures bound O-ring temperatures anticipated during normal storage in K-Area Complex (KAC). Leak test failures have been experienced in all of the GLT-S O-ring fixtures aging at 300 ºF and above. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 ºF for 6.9 to 7.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty still exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.« less
SIXTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2011-08-31
A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for seven years at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues formore » 33 GLT O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 F and higher temperatures, and in 7 fixtures aging at 300 F. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 41-60 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 F will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging within the past year at an intermediate temperature of 270 F, with hopes that they may leak before the 200 F fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200-300 F for up to 26 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-96%. This is greater than seen to date for packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350-400 F). However, at 300 F, the room temperature leak test failures to date experienced longer aging times than predicted by the CSR-based model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 F will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.« less
Leak detection using structure-borne noise
NASA Technical Reports Server (NTRS)
Holland, Stephen D. (Inventor); Roberts, Ronald A. (Inventor); Chimenti, Dale E. (Inventor)
2010-01-01
A method for detection and location of air leaks in a pressure vessel, such as a spacecraft, includes sensing structure-borne ultrasound waveforms associated with turbulence caused by a leak from a plurality of sensors and cross correlating the waveforms to determine existence and location of the leak. Different configurations of sensors and corresponding methods can be used. An apparatus for performing the methods is also provided.
Testing methods and techniques: Testing electrical and electronic devices: A compilation
NASA Technical Reports Server (NTRS)
1972-01-01
The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Austin Douglas; Runnels, Joel T.; Moore, Murray E.
A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canistermore » integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.« less
Preparation of calibrated test packages for particle impact noise detection
NASA Technical Reports Server (NTRS)
1977-01-01
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
Passive Acoustic Leak Detection for Sodium Cooled Fast Reactors Using Hidden Markov Models
NASA Astrophysics Data System (ADS)
Marklund, A. Riber; Kishore, S.; Prakash, V.; Rajan, K. K.; Michel, F.
2016-06-01
Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970s and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control.
Evaluation of Esophageal Anastomotic Integrity With Serial Pleural Amylase Levels.
Miller, Daniel L; Helms, Gerald A; Mayfield, William R
2018-01-01
An anastomotic leak is the most devastating and potentially fatal complication after esophagectomy. Current detection methods can be inaccurate and place patients at risk of other complications. Analysis of pleural fluid for amylase may be more accurate and place patients at less of a risk for evaluating the integrity of an esophageal anastomosis. We retrospectively reviewed prospective data of 45 consecutive patients who underwent an Ivor Lewis esophagectomy over an 18-month period and evaluated their anastomotic integrity with serial pleural amylase levels (PAL). There were 40 men (89%), and median age was 63 years (range, 35 to 79). Indication for esophagectomy was cancer in 38 patients (84%); 27 (71%) underwent neoadjuvant chemoradiation. A barium swallow was performed in the first 25 patients at median postoperative day (POD) 5 (range, 5 to 10); the swallow was negative in 23 patients (93%). Serial PALs were obtained starting on POD 3 and stopped 1 day after toleration of clear liquids. The PALs in the no-leak patients were highest on POD 3 (median 42 IU/L; range, 20 to 102 IU/L) and decreased (median 15 IU/L; range, 8 to 34 IU/L) to the lowest levels 1 day after clear liquid toleration (p = 0.04). Two patients had a leak and had peak PALs of 227 IU/L and 630 IU/L, respectively; both leaks occurred on POD 4, 1 day before their scheduled swallow test. The last 20 patients underwent serial PALs only, without a planned swallow test or computed tomography scan for anastomotic integrity evaluation. One of these patients had a leak on POD 5 with a low PAL of 55 IU/L the day before the spike of more than 4,000 IU/L. Two of the leaks were treated with esophageal stent placement and intravenous antibiotics, and the remaining patient's leak resolved with intravenous antibiotics, no oral intake, and observation only. None of the leak patients required transthoracic esophageal repair or drainage of an empyema. There was 1 postoperative death (2%) secondary to aspiration pneumonia on POD 10; no leak was ever identified, and the patient had been eating for 3 days before death. Complications occurred in 15 patients (33%), most commonly respiratory; no respiratory issues occurred in PAL-only evaluated patients. No late anastomotic leaks occurred in any patient while in the hospital or after discharge. Serial PALs for the detection of esophageal anastomotic leaks proved to be accurate, safe, and inexpensive. Elimination of barium swallows and computed tomography scans for evaluation of anastomotic integrity may decrease aspiration risks as well as associated pulmonary failure during the postoperative period. Serial PALs may be the preferred method of detecting an anastomotic leak after esophagectomy. A prospective randomized study is warranted. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2014-08-06
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determinemore » if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.« less
40 CFR 63.11495 - What are the management practices and other requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... or demonstrate that the HAP concentration in the cooling water does not constitute a leak, as defined... vessels and equipment are sound and free of leaks. For these inspections, detection methods incorporating...) inspection of all areas of potential leak within the CMPU. Indications of a leak identified using such method...
40 CFR 65.117 - Alternative means of emission limitation: Batch processes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.117 Alternative means... section provide the options of pressure testing or monitoring the equipment for leaks. The owner or... pressure-tested for leaks before regulated material is first fed to the equipment and the equipment is...
Slow crack growth test method for polyethylene gas pipes. Volume 1. Topical report, December 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leis, B.; Ahmad, J.; Forte, T.
1992-12-01
In spite of the excellent performance record of polyethylene (PE) pipes used for gas distribution, a small number of leaks occur in distribution systems each year because of slow growth of cracks through pipe walls. The Slow Crack Growth Test (SCG) has been developed as a key element in a methodology for the assessment of the performance of polyethylene gas distribution systems to resist such leaks. This tropical report describes work conducted in the first part of the research directed at the initial development of the SCG test, including a critical evaluation of the applicability of the SCG test asmore » an element in PE gas pipe system performance methodology. Results of extensive experiments and analysis are reported. The results show that the SCG test should be very useful in performance assessment.« less
Dulce, Raul A.; Mayo, Vera; Rangel, Erika B.; Balkan, Wayne; Hare, Joshua M.
2014-01-01
Rationale While nitric oxide (NO) signaling modulates cardiac function and excitation-contraction coupling, opposing results due to inconsistent experimental conditions, particularly with respect to temperature, confound the ability to elucidate NO signaling pathways. Here we show that temperature significantly modulates NO effects. Objective Test the hypothesis that temperature profoundly impacts nitroso-redox equilibrium, thereby affecting sarcomeric reticulum (SR) Ca2+ leak. Methods and Results We measured SR Ca2+ leak in cardiomyocytes from wild-type (WT), NO/redox imbalance (NOS1−/−), and hyper S-nitrosylation (GSNOR−/−) mice. In WT cardiomyocytes, SR Ca2+ leak increased as temperature decreased from 37°C to 23°C, whereas, in NOS1−/ −cells, the leak suddenly increased when the temperature surpassed 30°C. GSNOR−/ − cardiomyocytes exhibited low leak throughout the temperature range. Exogenously added NO had a biphasic effect on NOS1−/− cardiomyocytes; reducing leak at 37°C but increasing it at sub-physiologic temperatures. Oxypurinol and Tempol diminished the leak in NOS1−/ − cardiomyocytes. Cooling from 37° to 23°C increased ROS generation in WT but decreased it in NOS1−/− cardiomyocytes. Oxypurinol further reduced ROS generation. At 23°C in WT cells, leak was decreased by tetrahydrobiopterin, an essential NOS cofactor. Cooling significantly increased SR Ca2+ content in NOS1−/− cells but had no effect in WT or GSNOR−/−. Conclusions Ca2+ leak and temperature are normally inversely proportional, whereas NOS1 deficiency reverses this effect, increasing leak and elevating ROS production as temperature increases. Reduced denitrosylation (GSNOR deficiency) eliminates the temperature dependence of leak. Thus, temperature regulates the balance between NO and ROS which in turn has a major impact on SR Ca2+. PMID:25326127
Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA
2010-07-13
A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.
Li, Huan; Wang, Daofeng; Wei, Wenxiao; Ouyang, Lamei; Lou, Ning
2017-01-01
Anastomotic leak was a potentially severe life-threatening complication of esophagectomy, which drew attention in consequence of progressive dyspnea until acute respiratory distress syndrome (ARDS) due to the early asymptomatic presentation. Respiratory failure, caused by ARDS as the severe presentation of anastomotic leak, is the most common organ failure. CRP (C-reactive protein), procalcitonin (PCT), and Blood G (BG) test are the sensitivity markers for inflammatory, sepsis, and fungemia, respectively. Early recognition and intervention treatment of anastomotic leak may alleviate complication and improve outcome. We retrospectively analyzed 71 patients, accepting mechanical ventilation support because of ARDS as the complication after radical resection of esophagus cancer. Clinical data were collected from the patients' electronic medical records, including their clinically hematological examination, drainage fluid cultures, and sputum culture. Accord to appearance of anastomotic leak or not, all patients were divided into 2 groups, leak group and no-leak group. Inflammatory markers, such as CRP, PCT, and the coefficient of BG and PCT, were significantly different between the 2 groups. Respiratory index, white blood cell, hemoglobin (HBG), platelet (PLT), and other clinical factors were not significantly different between the 2 groups. Receiver operating characteristic curves were constructed to calculate the sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve for various cutoff levels of several factors. Blood G tests presented the better predicting value for anastomotic leak. Blood G tests and PCT should be tested after esophagectomy. The coefficient of PCT and BG (>260) is of great significance, and clinical value to predict anastomotic leak for patients with postesophagectomy ARDS, early PCT and BG test, and especially, dynamic variation may alleviate complication and improve outcome.
Process fault detection and nonlinear time series analysis for anomaly detection in safeguards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burr, T.L.; Mullen, M.F.; Wangen, L.E.
In this paper we discuss two advanced techniques, process fault detection and nonlinear time series analysis, and apply them to the analysis of vector-valued and single-valued time-series data. We investigate model-based process fault detection methods for analyzing simulated, multivariate, time-series data from a three-tank system. The model-predictions are compared with simulated measurements of the same variables to form residual vectors that are tested for the presence of faults (possible diversions in safeguards terminology). We evaluate two methods, testing all individual residuals with a univariate z-score and testing all variables simultaneously with the Mahalanobis distance, for their ability to detect lossmore » of material from two different leak scenarios from the three-tank system: a leak without and with replacement of the lost volume. Nonlinear time-series analysis tools were compared with the linear methods popularized by Box and Jenkins. We compare prediction results using three nonlinear and two linear modeling methods on each of six simulated time series: two nonlinear and four linear. The nonlinear methods performed better at predicting the nonlinear time series and did as well as the linear methods at predicting the linear values.« less
External detection and localization of well leaks in aquifer zones
NASA Astrophysics Data System (ADS)
Haas, Allan K.
This dissertation presents a new methodology for monitoring, detecting, and localizing shallow, aquifer zone leaks in oil and gas wells. The rationale for this type of leak detection is to close the knowledge gap associated with public claims of subsurface water resource contamination caused by the oil and gas industry. A knowledge gap exists because there is no data, one way or the other, that can definitively prove or deny the existence of subsurface leakage pathways in oil and gas wells, new, old or abandoned. This dissertation begins with an overview of existing and future oil and gas well leak detection methods, and then presents three published papers, each describing a different phenomena that can be exploited for leak monitoring, detection, localization, and damage extent determination. The first paper describes the direct detection and localization of a leak that was discovered during a laboratory based hydraulic fracturing experiment. The second paper describes the laboratory measured electrical response that occurs during two phase flow inside of porous media. The third paper describes the detection and tracking of a gravity driven salt plume leak in a freshwater test tank in the laboratory. the three geophysical approaches that are presented, when combined together, provide a new, powerful, external to the well method to monitor, detect, localize, and assess the damage from leaks in the drinking water protection zone of oil and gas wells. This is a capability that is not available in any other leak detection and localization method. This dissertation also presents a chapter of Science, Technology and Society (STS), and Science, and Technology Policy (STP) as a final fulfillment requirement of the SmartGeo Fellowship program, and the Science, Technology, Engineering, and Policy minor. This chapter introduces a new STS/STP concept concerning the after effects of knowledge boundary disputes. This new concept is called the residual footprints of knowledge boundary disputes. This new concept is developed through the analysis of an oil and gas drilling controversy that climaxed in Erie, CO in 2012. Additional evidence of this residual footprint concept is also presented in a very brief form. It is hoped that this new concept will be further researched, and adopted by the STS/STP community.
Method and means of passive detection of leaks in buried pipes
Claytor, T.
1979-10-30
A method and means for passive detection of a leak in a buried pipe containing fluid under pressure includes a plurality of acoustic detectors that are placed in contact with the pipe. Noise produced by the leak is detected by the detectors, and the detected signals are correlated to locate the leak. In one embodiment of the invention two detectors are placed at different locations to locate a leak between them. In an alternate embodiment two detectors of different waves are placed at substantially the same location to determine the distance of the leak from the location.
Method and means of passive detection of leaks in buried pipes
Claytor, Thomas N.
1981-01-01
A method and means for passive detection of a leak in a buried pipe containing fluid under pressure includes a plurality of acoustic detectors that are placed in contact with the pipe. Noise produced by the leak is detected by the detectors, and the detected signals are correlated to locate the leak. In one embodiment of the invention two detectors are placed at different locations to locate a leak between them. In an alternate embodiment two detectors of different waves are placed at substantially the same location to determine the distance of the leak from the location.
A multicenter study of routine versus selective intraoperative leak testing for sleeve gastrectomy.
Bingham, Jason; Kaufman, Jedediah; Hata, Kai; Dickerson, James; Beekley, Alec; Wisbach, Gordon; Swann, Jacob; Ahnfeldt, Eric; Hawkins, Devon; Choi, Yong; Lim, Robert; Martin, Matthew
2017-09-01
Staple line leaks after sleeve gastrectomy are dreaded complications. Many surgeons routinely perform an intraoperative leak test (IOLT) despite little evidence to validate the reliability, clinical benefit, and safety of this procedure. To determine the efficacy of IOLT and if routine use has any benefit over selective use. Eight teaching hospitals, including private, university, and military facilities. A multicenter, retrospective analysis over a 5-year period. The efficacy of the IOLT for identifying unsuspected staple line defects and for predicting postoperative leaks was evaluated. An anonymous survey was also collected reflecting surgeons' practices and beliefs regarding IOLT. From January 2010 through December 2014, 4284 patients underwent sleeve gastrectomy. Of these, 37 patients (.9%) developed a postoperative leak, and 2376 patients (55%) received an IOLT. Only 2 patients (0.08%) had a positive finding. Subsequently, 21 patients with a negative IOLT developed a leak. IOLT demonstrated a sensitivity of only 8.7%. There was a nonsignificant trend toward increased leak rates when an IOLT was performed versus when IOLT was not performed. Leak rates were not statistically different between centers that routinely perform IOLT versus those that selectively perform IOLT. Routine IOLT had very poor sensitivity and was negative in 91% of patients who later developed postoperative leaks. The use of IOLT was not associated with a decrease in the incidence of postoperative leaks, and routine IOLT had no benefit over selective leak testing. IOLT should not be used as a quality indicator or "best practice" for bariatric surgery. Published by Elsevier Inc.
Hazardous Gas Leak Analysis in the Space Shuttle
NASA Technical Reports Server (NTRS)
Barile, Ronald G.
1991-01-01
Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.
Rapid, Vehicle-Based Identification of Location and Magnitude of Urban Natural Gas Pipeline Leaks.
von Fischer, Joseph C; Cooley, Daniel; Chamberlain, Sam; Gaylord, Adam; Griebenow, Claire J; Hamburg, Steven P; Salo, Jessica; Schumacher, Russ; Theobald, David; Ham, Jay
2017-04-04
Information about the location and magnitudes of natural gas (NG) leaks from urban distribution pipelines is important for minimizing greenhouse gas emissions and optimizing investment in pipeline management. To enable rapid collection of such data, we developed a relatively simple method using high-precision methane analyzers in Google Street View cars. Our data indicate that this automated leak survey system can document patterns in leak location and magnitude within and among cities, even without wind data. We found that urban areas with prevalent corrosion-prone distribution lines (Boston, MA, Staten Island, NY, and Syracuse, NY), leaked approximately 25-fold more methane than cities with more modern pipeline materials (Burlington, VT, and Indianapolis, IN). Although this mobile monitoring method produces conservative estimates of leak rates and leak counts, it can still help prioritize both leak repairs and replacement of leak-prone sections of distribution lines, thus minimizing methane emissions over short and long terms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Lanning; J. Arps
2004-04-01
Extending upon development efforts last quarter to produce ''free-standing'', copper and palladium alloy films, the goal this quarter has been to produce pinhole-free, Pd-Cu alloy films up to 5 x 5 inches in area (1-3 microns thick) using both magnetron sputtering and e-beam evaporation on PVA (Solublon) and polystyrene backing materials. A set of experiments were conducted to assess processing methods/solutions chemistry for removing the polymer backing material from the Pd-Cu film. For all of the alloy films produced to this point, we were unable to produce pinhole-free films on plastic although we were able to produce free-standing Pd-Cu filmsmore » at less than 0.5 microns thick with minimal intrinsic stress. Subsequently, to evaluate gas permeation and leakage across the films, two films were sandwiched together on top of a porous Monel support disc (25 mm in diameter) and then tested in a leak test apparatus. Using two Cu films (10 micron thickness total) in the sandwich configuration, leak rates were about 20% of the background leak rate.« less
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...
Leak Detection by Acoustic Emission Monitoring. Phase 1. Feasibility Study
1994-05-26
various signal processing and noise descrimInation techniques during the Data Processing task. C. TEST DESCRIPTION 1. Laboratory Tests Following normal...success in applying these methods to descriminating between the AE bursts generated by two close AE sources In a section of an aircraft structure
Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James
2017-01-01
USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a guide for method development of container closure integrity tests. LAY ABSTRACT: The new USP 39 <1207>, "Package Integrity Evaluation-Sterile Products", states in section 3.4.1: "tracer gas tests performed using … laser-based gas headspace analysis [have] been shown to be sensitive enough to quantitatively analyze leakage through the smallest leak paths found to pose the smallest chance of liquid leakage or microbial ingress in rigid packaging." In addition, USP <1207> also states that "for such methods, the limit of detection can be mathematically predicted on the basis of gas flow kinetics." Using the above statements as a foundation, this paper presents a theoretical basis for predicting the gas ingress through well-defined defects in product vials sealed under a variety of headspace conditions. These calculated predictions were experimentally validated by comparing them to measurements of changes in the headspace oxygen content or total pressure for several different positive controls using laser-based headspace analysis. The results demonstrated that laser-based headspace analysis can, by readily differentiating between negative controls and positive controls with a range of defect sizes on the micron scale, be used to assess container closure integrity. The work also demontrated that caution must be used when attempting to correlate a leak rate to an idealized defect-size parameter. © PDA, Inc. 2017.
A harmonic pulse testing method for leakage detection in deep subsurface storage formations
NASA Astrophysics Data System (ADS)
Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan
2015-06-01
Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.
Command and Control Software Development Memory Management
NASA Technical Reports Server (NTRS)
Joseph, Austin Pope
2017-01-01
This internship was initially meant to cover the implementation of unit test automation for a NASA ground control project. As is often the case with large development projects, the scope and breadth of the internship changed. Instead, the internship focused on finding and correcting memory leaks and errors as reported by a COTS software product meant to track such issues. Memory leaks come in many different flavors and some of them are more benign than others. On the extreme end a program might be dynamically allocating memory and not correctly deallocating it when it is no longer in use. This is called a direct memory leak and in the worst case can use all the available memory and crash the program. If the leaks are small they may simply slow the program down which, in a safety critical system (a system for which a failure or design error can cause a risk to human life), is still unacceptable. The ground control system is managed in smaller sub-teams, referred to as CSCIs. The CSCI that this internship focused on is responsible for monitoring the health and status of the system. This team's software had several methods/modules that were leaking significant amounts of memory. Since most of the code in this system is safety-critical, correcting memory leaks is a necessity.
The Demonstration of a Robotic External Leak Locator on the International Space Station
NASA Technical Reports Server (NTRS)
Naids, Adam; Rossetti, Dino; Bond, Tim; Johnson, Brien; Huang, Alvin; Deal, Alexandra; Fox, Katie; Heiser, Michael; Hartman, William; Mikatarian, Ronald
2017-01-01
The International Space Station (ISS) and all currently conceivable future manned spacecraft are susceptible to mission impacts due to fluid/gas leaks to the exterior environment. For example, there is a well-known risk of ammonia leaks from the ISS External Thermal Control System loops and currently no method to locate them. It was, therefore, critical to develop a method for detecting and locating leaks to preserve vehicle health. The Robotic External Leak Locator (RELL) was developed and deployed to the ISS to provide this capability. An on-orbit validation and demonstration was successfully completed in December 2016 and leak locating operations occurred in February 2017. This paper discusses the results of those exercises including measurements of the environment around ISS, detection of the small ammonia leak and implementation of leak locating methodologies.
SEVENTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2012-08-30
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23more » GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 54-72 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 ºF will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 30 - 36 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51 – 96%. This is greater than seen to date for any packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350 – 400 ºF). However, at 300 ºF, the room temperature leak test failures to date experienced longer aging times than predicted by the CSRbased model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 ºF will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining PCV O-ring fixtures.« less
40 CFR 63.1046 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... test, the cover and closure devices shall be secured in the closed position. (3) The detection... constituent. (4) The detection instrument shall be calibrated before use on each day of its use by the...
40 CFR 280.52 - Release investigation and confirmation steps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... testing in § 280.43(c) and § 280.44(b)) that determine whether a leak exists in that portion of the tank... F if the test results for the system, tank, or delivery piping indicate that a leak exists. (2... indicate that a leak exists and if environmental contamination is not the basis for suspecting a release...
Detecting subsurface fluid leaks in real-time using injection and production rates
NASA Astrophysics Data System (ADS)
Singh, Harpreet; Huerta, Nicolas J.
2017-12-01
CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to detecting the time when a leak is activated and the volume of that leakage, this method provides an insight about the leak location, and reservoir connectivity. We are proposing this as a complementary method that can be used with other, more expensive, methods early on in the injection process. This will allow an operator to conduct more expensive surveys less often because the proposed method can show if there are no leaks on a monthly basis that is cheap and fast.
Risk Factors for Gastrointestinal Leak after Bariatric Surgery: MBASQIP Analysis.
Alizadeh, Reza Fazl; Li, Shiri; Inaba, Colette; Penalosa, Patrick; Hinojosa, Marcelo W; Smith, Brian R; Stamos, Michael J; Nguyen, Ninh T
2018-03-30
Gastrointestinal leak remains one of the most dreaded complications in bariatric surgery. We aimed to evaluate risk factors and the impact of common perioperative interventions on the development of leak in patients who underwent laparoscopic bariatric surgery. Using the 2015 database of accredited centers, data were analyzed for patients who underwent laparoscopic sleeve gastrectomy or Roux-en-Y gastric bypass (LRYGB). Emergent, revisional, and converted cases were excluded. Multivariate logistic regression was used to analyze risk factors for leak, including provocative testing of anastomosis, surgical drain placement, and use of postoperative swallow study. Data from 133,478 patients who underwent laparoscopic sleeve gastrectomy (n = 92,495 [69.3%]) and LRYGB (n = 40,983 [30.7%]) were analyzed. Overall leak rate was 0.7% (938 of 133,478). Factors associated with increased risk for leak were oxygen dependency (adjusted odds ratio [AOR] 1.97), hypoalbuminemia (AOR 1.66), sleep apnea (AOR 1.52), hypertension (AOR 1.36), and diabetes (AOR 1.18). Compared with LRYGB, laparoscopic sleeve gastrectomy was associated with a lower risk of leak (AOR 0.52; 95% CI 0.44 to 0.61; p < 0.01). Intraoperative provocative test was performed in 81.9% of cases and the leak rate was higher in patients with vs without a provocative test (0.8% vs 0.4%, respectively; p < 0.01). A surgical drain was placed in 24.5% of cases and the leak rate was higher in patients with vs without a surgical drain placed (1.6% vs 0.4%, respectively; p < 0.01). A swallow study was performed in 41% of cases and the leak rate was similar between patients with vs without swallow study (0.7% vs 0.7%; p = 0.50). The overall rate of gastrointestinal leak in bariatric surgery is low. Certain preoperative factors, procedural type (LRYGB), and interventions (intraoperative provocative test and surgical drain placement) were associated with a higher risk for leaks. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Amran, T. S. T.; Ismail, M. P.; Ahmad, M. R.; Amin, M. S. M.; Ismail, M. A.; Sani, S.; Masenwat, N. A.; Basri, N. S. M.
2018-01-01
Water is the most treasure natural resources, however, a huge amount of water are lost during its distribution that leads to water leakage problem. The leaks meant the waste of money and created more economic loss to treat and fix the damaged pipe. Researchers and engineers have put tremendous attempts and effort, to solve the water leakage problem especially in water leakage of buried pipeline. An advanced technology of ground penetrating radar (GPR) has been established as one of the non-destructive testing (NDT) method to detect the underground water pipe leaking. This paper focuses on the ability of GPR in water utility field especially on detection of water leaks in the underground pipeline distribution. A series of laboratory experiments were carried out using 800-MHz antenna, where the performance of GPR on detecting underground pipeline and locating water leakage was investigated and validated. A prototype to recreate water-leaking system was constructed using a 4-inch PVC pipe. Different diameter of holes, i.e. ¼ inch, ½ inch, and ¾ inch, were drilled into the pipe to simulate the water leaking. The PVC pipe was buried at the depth of 60 cm into the test bed that was filled with dry sand. 15 litres of water was injected into the PVC pipe. The water leakage patterns in term of radargram data were gathered. The effectiveness of the GPR in locating the underground water leakage was ascertained, after the results were collected and verified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isozaki, Toshikuni; Shibata, Katsuyuki
1997-04-01
Experimental and computed results applicable to Leak Before Break analysis are presented. The specific area of investigation is the effect of the temperature distribution changes due to wetting of the test pipe near the crack on the increase in the crack opening area and leak rate. Two 12-inch straight pipes subjected to both internal pressure and thermal load, but not to bending load, are modelled. The leak rate was found to be very susceptible to the metal temperature of the piping. In leak rate tests, therefore, it is recommended that temperature distribution be measured precisely for a wide area.
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover... secured in the closed position. (3) The detection instrument shall meet the performance criteria of Method... in the unit, not for each individual organic constituent. (4) The detection instrument shall be...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover... secured in the closed position. (3) The detection instrument shall meet the performance criteria of Method... in the unit, not for each individual organic constituent. (4) The detection instrument shall be...
NASA Technical Reports Server (NTRS)
Koch, D. E.; Stephenson, J. G.
1983-01-01
Hole sizes deduced from pressure measurements. Measuring apparatus consists of pitot tube attached to water-filled manometer. Compartment tested is pressurized with air. Pitot probe placed at known distance from leak. Dynamic pressure of jet measured at that point and static pressure measured in compartment. Useful in situations in which small leaks are tolerable but large leaks are not.
Investigation of Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle
NASA Astrophysics Data System (ADS)
Yang, S.; Talbot, R. W.; Frish, M. B.; Golston, L.; Aubut, N. F.; Zondlo, M. A.
2017-12-01
The U.S is now the world's largest natural gas producer, of which methane (CH4) is the main component. About 2% of the CH4 is lost through fugitive leaks. This research is under the DOE Methane Observation Networks with Innovative Technology to Obtain Reductions (MONITOR) program of ARPA-E. Our sentry measurement system is composed of four state-of-the-art technologies centered around the RMLDTM (Remote Methane Leak Detector). An open path RMLDTM measures column-integrated CH4 concentration that incorporates fluctuations in the vertical CH4 distribution. Based on Backscatter Tunable Diode Laser Absorption Spectroscopy and Small Unmanned Aerial Vehicles, the sentry system can autonomously, consistently and cost-effectively monitor and quantify CH4 leakage from sites associated with natural gas production. This system provides an advanced capability in detecting leaks at hard-to-access sites (e.g., wellheads) compared to traditional manual methods. Automated leak detecting and reporting algorithms combined with wireless data link implement real-time leak information reporting. Early data were gathered to set up and test the prototype system, and to optimize the leak localization and calculation strategies. The flight pattern is based on a raster scan which can generate interpolated CH4 concentration maps. The localization and quantification algorithms can be derived from the plume images combined with wind vectors. Currently, the accuracy of localization algorithm can reach 2 m and the calculation algorithm has a factor of 2 accuracy. This study places particular emphasis on flux quantification. The data collected at Colorado and Houston test fields were processed, and the correlation between flux and other parameters analyzed. Higher wind speeds and lower wind variation are preferred to optimize flux estimation. Eventually, this system will supply an enhanced detection capability to significantly reduce fugitive CH4 emissions in the natural gas industry.
Identification of sewage leaks by active remote-sensing methods
NASA Astrophysics Data System (ADS)
Goldshleger, Naftaly; Basson, Uri
2016-04-01
The increasing length of sewage pipelines, and concomitant risk of leaks due to urban and industrial growth and development is exposing the surrounding land to contamination risk and environmental harm. It is therefore important to locate such leaks in a timely manner, to minimize the damage. Advances in active remote sensing Ground Penetrating Radar (GPR) and Frequency Domain Electromagnetic (FDEM) technologies was used to identify leaking potentially responsible for pollution and to identify minor spills before they cause widespread damage. This study focused on the development of these electromagnetic methods to replace conventional acoustic methods for the identification of leaks along sewage pipes. Electromagnetic methods provide an additional advantage in that they allow mapping of the fluid-transport system in the subsurface. Leak-detection systems using GPR and FDEM are not limited to large amounts of water, but enable detecting leaks of tens of liters per hour, because they can locate increases in environmental moisture content of only a few percentage along the pipes. The importance and uniqueness of this research lies in the development of practical tools to provide a snapshot and monitoring of the spatial changes in soil moisture content up to depths of about 3-4 m, in open and paved areas, at relatively low cost, in real time or close to real time. Spatial measurements performed using GPR and FDEM systems allow monitoring many tens of thousands of measurement points per hectare, thus providing a picture of the spatial situation along pipelines and the surrounding. The main purpose of this study was to develop a method for detecting sewage leaks using the above-proposed geophysical methods, since their contaminants can severely affect public health. We focused on identifying, locating and characterizing such leaks in sewage pipes in residential and industrial areas.
NASA Technical Reports Server (NTRS)
Weber, Philip
2008-01-01
Ground crew veterans at Kennedy Space Center still talk about what they call "the summer of hydrogen"-the long, frustrating months in 1990 when the shuttle fleet was grounded by an elusive hydrogen leak that foiled our efforts to fill the orbiter's external fuel tank. Columbia (STS-35) was on Launch Pad A for a scheduled May 30 launch when we discovered the hydrogen leak during - tanking. The external fuel tank is loaded through the orbiter. Liquid hydrogen flows through a 17-inch umbilical between the orbiter and the tank. During fueling, we purge the aft fuselage with gaseous nitrogen to reduce the risk of fire, and we have a leak-detection system in the mobile launch platform, which samples (via tygon tubing) the atmosphere in and around the vehicle, drawing it down to a mass spectrometer that analyzes its composition. When we progressed to the stage of tanking where liquid hydrogen flows through the vehicle, the concentration of hydrogen approached four percent-the limit above which it would be dangerously flammable. We had a leak. We did everything we could think of to find it, and the contractor who supplied the flight hardware was there every day, working alongside us. We did tanking tests, which involved instrumenting the suspected leak sources, and cryo-loaded the external tank to try to isolate precisely where the leak originated. We switched out umbilicals; we replaced the seals between the umbilical and the orbiter. We inspected the seals microscopically and found no flaws. We replaced the recirculation pumps, and we found and replaced a damaged teflon seal in a main propulsion system detent cover, which holds the prevalve-the main valve supplying hydrogen to Space Shuttle Main Engine 3 -in the open position. The seal passed leak tests at ambient temperature but leaked when cryogenic temperatures were applied. We added new leak sensors-up to twenty at a time and tried to be methodical in our placements to narrow down the possible sources of the problem. We even switched orbiters, sending Columbia back to the Vehicle Assembly Building and bringing out Atlantis, scheduled to fly as STS-38. Two shuttles on their mobile launchers passing in the night was a majestic sight, but not one you want to see if you're trying to get an orbiter launched. None of this told us where the leak was, or if we were dealing with more than one leak source.
40 CFR 61.245 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane. (5) The instrument probe shall be traversed around all potential leak interfaces as close to the...
40 CFR 61.245 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane. (5) The instrument probe shall be traversed around all potential leak interfaces as close to the...
40 CFR 61.245 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane. (5) The instrument probe shall be traversed around all potential leak interfaces as close to the...
40 CFR 61.245 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane. (5) The instrument probe shall be traversed around all potential leak interfaces as close to the...
40 CFR 61.245 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane. (5) The instrument probe shall be traversed around all potential leak interfaces as close to the...
40 CFR 63.1107 - Equipment leaks: applicability assessment procedures and methods.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Equipment leaks: applicability assessment procedures and methods. 63.1107 Section 63.1107 Protection of Environment ENVIRONMENTAL PROTECTION... Categories: Generic Maximum Achievable Control Technology Standards § 63.1107 Equipment leaks: applicability...
Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riber Marklund, A.; Kishore, S.; Prakash, V.
2015-07-01
Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), themore » proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)« less
NASA Technical Reports Server (NTRS)
Woronowicz, Michael; Abel, Joshua; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin;
2014-01-01
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.
NASA Technical Reports Server (NTRS)
Woronowicz, Michael S.; Abel, Joshua C.; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin;
2014-01-01
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system.An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (directionality).The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbmyr. to about 1 lbmday. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ramwake flows and structural shadowing within low Earth orbit.
Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo
2016-12-13
In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods.
Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo
2016-01-01
In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods. PMID:27983577
40 CFR 63.425 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... location for each leak. (g) Nitrogen pressure decay field test. For those cargo tanks with manifolded... adding commercial grade nitrogen gas from a high pressure cylinder capable of maintaining a pressure of 2... and a flow control metering valve. The flow rate of the nitrogen shall be no less than 2 cfm. The...
40 CFR 63.425 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... location for each leak. (g) Nitrogen pressure decay field test. For those cargo tanks with manifolded... adding commercial grade nitrogen gas from a high pressure cylinder capable of maintaining a pressure of 2... and a flow control metering valve. The flow rate of the nitrogen shall be no less than 2 cfm. The...
40 CFR 63.425 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... location for each leak. (g) Nitrogen pressure decay field test. For those cargo tanks with manifolded... adding commercial grade nitrogen gas from a high pressure cylinder capable of maintaining a pressure of 2... and a flow control metering valve. The flow rate of the nitrogen shall be no less than 2 cfm. The...
40 CFR 63.425 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... location for each leak. (g) Nitrogen pressure decay field test. For those cargo tanks with manifolded... adding commercial grade nitrogen gas from a high pressure cylinder capable of maintaining a pressure of 2... and a flow control metering valve. The flow rate of the nitrogen shall be no less than 2 cfm. The...
40 CFR 63.425 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... location for each leak. (g) Nitrogen pressure decay field test. For those cargo tanks with manifolded... adding commercial grade nitrogen gas from a high pressure cylinder capable of maintaining a pressure of 2... and a flow control metering valve. The flow rate of the nitrogen shall be no less than 2 cfm. The...
Apparatus for Leak Testing Pressurized Hoses
NASA Technical Reports Server (NTRS)
Underwood, Steve D. (Inventor); Garrison, Steve G. (Inventor); Gant, Bobby D. (Inventor); Palmer, John R. (Inventor)
2015-01-01
A hose-attaching apparatus for leak-testing a pressurized hose may include a hose-attaching member. A bore may extend through the hose-attaching member. An internal annular cavity may extend coaxially around the bore. At least one of a detector probe hole and a detector probe may be connected to the internal annular cavity. At least a portion of the bore may have a diameter which is at least one of substantially equal to and less than a diameter of a hose to be leak-tested.
Design of oil pipeline leak detection and communication system based on optical fiber technology
NASA Astrophysics Data System (ADS)
Tu, Yaqing; Chen, Huabo
1999-08-01
The integrity of oil pipeline is always a major concern of operators. Pipeline leak not only leads to loss of oil, but pollutes environment. A new pipeline leak detection and communication system based on optical fiber technology to ensure the pipeline reliability is presented. Combined direct leak detection method with an indirect one, the system will greatly reduce the rate of false alarm. According, to the practical features of oil pipeline,the pipeline communication system is designed employing the state-of-the-art optic fiber communication technology. The system has such feature as high location accuracy of leak detection, good real-time characteristic, etc. which overcomes the disadvantages of traditional leak detection methods and communication system effectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-07-01
Air sealing of building enclosures is a difficult and time-consuming process. Current methods in new construction require laborers to physically locate small and sometimes large holes in multiple assemblies and then manually seal each of them. The innovation demonstrated under this research study was the automated air sealing and compartmentalization of buildings through the use of an aerosolized sealant, developed by the Western Cooling Efficiency Center at University of California Davis.CARB sought to demonstrate this new technology application in a multifamily building in Queens, NY. The effectiveness of the sealing process was evaluated by three methods: air leakage testing ofmore » overall apartment before and after sealing, point-source testing of individual leaks, and pressure measurements in the walls of the target apartment during sealing. Aerosolized sealing was successful by several measures in this study. Many individual leaks that are labor-intensive to address separately were well sealed by the aerosol particles. In addition, many diffuse leaks that are difficult to identify and treat were also sealed. The aerosol-based sealing process resulted in an average reduction of 71% in air leakage across three apartments and an average apartment airtightness of 0.08 CFM50/SF of enclosure area.« less
Test/QA Plan for Verification of Leak Detection and Repair Technologies
The purpose of the leak detection and repair (LDAR) test and quality assurance plan is to specify procedures for a verification test applicable to commercial LDAR technologies. The purpose of the verification test is to evaluate the performance of participating technologies in b...
Of Detection Limits and Effective Mitigation: The Use of Infrared Cameras for Methane Leak Detection
NASA Astrophysics Data System (ADS)
Ravikumar, A. P.; Wang, J.; McGuire, M.; Bell, C.; Brandt, A. R.
2017-12-01
Mitigating methane emissions, a short-lived and potent greenhouse gas, is critical to limiting global temperature rise to two degree Celsius as outlined in the Paris Agreement. A major source of anthropogenic methane emissions in the United States is the oil and gas sector. To this effect, state and federal governments have recommended the use of optical gas imaging systems in periodic leak detection and repair (LDAR) surveys to detect for fugitive emissions or leaks. The most commonly used optical gas imaging systems (OGI) are infrared cameras. In this work, we systematically evaluate the limits of infrared (IR) camera based OGI system for use in methane leak detection programs. We analyze the effect of various parameters that influence the minimum detectable leak rates of infrared cameras. Blind leak detection tests were carried out at the Department of Energy's MONITOR natural gas test-facility in Fort Collins, CO. Leak sources included natural gas wellheads, separators, and tanks. With an EPA mandated 60 g/hr leak detection threshold for IR cameras, we test leak rates ranging from 4 g/hr to over 350 g/hr at imaging distances between 5 ft and 70 ft from the leak source. We perform these experiments over the course of a week, encompassing a wide range of wind and weather conditions. Using repeated measurements at a given leak rate and imaging distance, we generate detection probability curves as a function of leak-size for various imaging distances, and measurement conditions. In addition, we estimate the median detection threshold - leak-size at which the probability of detection is 50% - under various scenarios to reduce uncertainty in mitigation effectiveness. Preliminary analysis shows that the median detection threshold varies from 3 g/hr at an imaging distance of 5 ft to over 150 g/hr at 50 ft (ambient temperature: 80 F, winds < 4 m/s). Results from this study can be directly used to improve OGI based LDAR protocols and reduce uncertainty in estimated mitigation effectiveness. Furthermore, detection limits determined in this study can be used as standards to compare new detection technologies.
Microseismic response characteristics modeling and locating of underground water supply pipe leak
NASA Astrophysics Data System (ADS)
Wang, J.; Liu, J.
2015-12-01
In traditional methods of pipeline leak location, geophones must be located on the pipe wall. If the exact location of the pipeline is unknown, the leaks cannot be identified accurately. To solve this problem, taking into account the characteristics of the pipeline leak, we propose a continuous random seismic source model and construct geological models to investigate the proposed method for locating underground pipeline leaks. Based on two dimensional (2D) viscoacoustic equations and the staggered grid finite-difference (FD) algorithm, the microseismic wave field generated by a leaking pipe is modeled. Cross-correlation analysis and the simulated annealing (SA) algorithm were utilized to obtain the time difference and the leak location. We also analyze and discuss the effect of the number of recorded traces, the survey layout, and the offset and interval of the traces on the accuracy of the estimated location. The preliminary results of the simulation and data field experiment indicate that (1) a continuous random source can realistically represent the leak microseismic wave field in a simulation using 2D visco-acoustic equations and a staggered grid FD algorithm. (2) The cross-correlation method is effective for calculating the time difference of the direct wave relative to the reference trace. However, outside the refraction blind zone, the accuracy of the time difference is reduced by the effects of the refracted wave. (3) The acquisition method of time difference based on the microseismic theory and SA algorithm has a great potential for locating leaks from underground pipelines from an array located on the ground surface. Keywords: Viscoacoustic finite-difference simulation; continuous random source; simulated annealing algorithm; pipeline leak location
Park, Jae Kil; Moon, Seok Whan
2017-01-01
Background Anastomotic leak is one of most significant causes of mortality after esophagectomy. Therefore, it is clinically valuable to detect anastomotic leak early after esophagectomy in esophageal cancer. The purpose of this study is to investigate the associations between routine postoperative laboratory findings and anastomotic leak and to analyze the laboratory findings to find out an independent predictive marker for anastomotic leak. In addition, this study compares cases treated with neoadjuvant therapy (NT) and those without (non-NT). Methods We retrospectively assessed the medical records of 201 consecutive cases that met this study’s criteria from January 2009 to December 2016. All patients underwent curative and complete esophagectomy for intra-thoracic esophageal cancer. We compiled and analyzed routine laboratory findings from the day before surgery to the eighth postoperative day on a daily basis. Routine laboratory tests consisted of 26 separate tests, including complete blood cell counts, blood chemistries, as well as erythrocyte sedimentation rate and C-reactive protein (CRP). Barium esophagogram with chest computed tomography (CT) was performed on the seventh postoperative day to evaluate the presence of an anastomotic leak. Results A total of 45 of 201 patients underwent NT. Anastomotic leaks were found in 23 (11.4%) of 201 patients (8 patients in NT and 15 patients in non-NT). White blood cell (WBC) from the second postoperative day (P=0.031, P=0.006, P=0.007, P=0.007, P=0.041, and P=0.003, respectively) and CRP from the third postoperative day (P=0.012, P<0.001, P=0.014, P<0.001, P=0.001, and P=0.006, respectively) were associated with anastomotic leak in non-NT; however, only CRP on the third, fifth, sixth, and seventh postoperative days (P=0.041, P=0.037, P=0.002, and P=0.003, respectively) was associated with anastomotic leak in NT. The CRP level on the third postoperative day was a significant independent predictive marker of anastomotic leak (P=0.041, odd ratio (OR) 1.056, 95% confidential interval (CI): 1.002–1.113) and had a significant diagnostic cutoff value for the development of anastomotic leak (non-NT: cutoff value 17.12 mg/dL, sensitivity 69.2%, specificity 78.1%, P<0.001, area 0.822; NT: cutoff value 16.42 mg/dL, sensitivity 80.0%, specificity 70.0%, P=0.042, area 0.7104). Conclusions There were divergent laboratory findings reflective of anastomotic leak between patients who underwent NT and those who did not. The CRP level on the third postoperative day had a significant cutoff value for early detection of anastomotic leak after esophagectomy in both NT and non-NT groups. PMID:29268376
A Review of Centrifugal Testing of Gasoline Contamination and Remediation
Meegoda, Jay N.; Hu, Liming
2011-01-01
Leaking underground storage tanks (USTs) containing gasoline represent a significant public health hazard. Virtually undetectable to the UST owner, gasoline leaks can contaminate groundwater supplies. In order to develop remediation plans one must know the extent of gasoline contamination. Centrifugal simulations showed that in silty and sandy soils gasoline moved due to the physical process of advection and was retained as a pool of free products above the water table. However, in clayey soils there was a limited leak with lateral spreading and without pooling of free products above the water table. Amount leaked depends on both the type of soil underneath the USTs and the amount of corrosion. The soil vapor extraction (SVE) technology seems to be an effective method to remove contaminants from above the water table in contaminated sites. In-situ air sparging (IAS) is a groundwater remediation technology for contamination below the water table, which involves the injection of air under pressure into a well installed into the saturated zone. However, current state of the art is not adequate to develop a design guide for site implementation. New information is being currently generated by both centrifugal tests as well as theoretical models to develop a design guide for IAS. The petroleum contaminated soils excavated from leaking UST sites can be used for construction of highway pavements, specifically as sub-base material or blended and used as hot or cold mix asphalt concrete. Cost analysis shows that 5% petroleum contaminated soils is included in hot or cold mix asphalt concrete can save US$5.00 production cost per ton of asphalt produced. PMID:21909320
A review of centrifugal testing of gasoline contamination and remediation.
Meegoda, Jay N; Hu, Liming
2011-08-01
Leaking underground storage tanks (USTs) containing gasoline represent a significant public health hazard. Virtually undetectable to the UST owner, gasoline leaks can contaminate groundwater supplies. In order to develop remediation plans one must know the extent of gasoline contamination. Centrifugal simulations showed that in silty and sandy soils gasoline moved due to the physical process of advection and was retained as a pool of free products above the water table. However, in clayey soils there was a limited leak with lateral spreading and without pooling of free products above the water table. Amount leaked depends on both the type of soil underneath the USTs and the amount of corrosion. The soil vapor extraction (SVE) technology seems to be an effective method to remove contaminants from above the water table in contaminated sites. In-situ air sparging (IAS) is a groundwater remediation technology for contamination below the water table, which involves the injection of air under pressure into a well installed into the saturated zone. However, current state of the art is not adequate to develop a design guide for site implementation. New information is being currently generated by both centrifugal tests as well as theoretical models to develop a design guide for IAS. The petroleum contaminated soils excavated from leaking UST sites can be used for construction of highway pavements, specifically as sub-base material or blended and used as hot or cold mix asphalt concrete. Cost analysis shows that 5% petroleum contaminated soils is included in hot or cold mix asphalt concrete can save US$5.00 production cost per ton of asphalt produced.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woronowicz, Michael; Blackmon, Rebecca; Brown, Martin
2014-12-09
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performancemore » to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.« less
Airborne LIDAR Pipeline Inspection System (ALPIS) Mapping Tests
DOT National Transportation Integrated Search
2003-06-06
Natural gas and hazardous liquid pipeline operators have a need to identify where leaks are occurring along their pipelines in order to lower the risks the pipelines pose to people and the environment. Current methods of locating natural gas and haza...
The effects of resonances on time delay estimation for water leak detection in plastic pipes
NASA Astrophysics Data System (ADS)
Almeida, Fabrício C. L.; Brennan, Michael J.; Joseph, Phillip F.; Gao, Yan; Paschoalini, Amarildo T.
2018-04-01
In the use of acoustic correlation methods for water leak detection, sensors are placed at pipe access points either side of a suspected leak, and the peak in the cross-correlation function of the measured signals gives the time difference (delay) between the arrival times of the leak noise at the sensors. Combining this information with the speed at which the leak noise propagates along the pipe, gives an estimate for the location of the leak with respect to one of the measurement positions. It is possible for the structural dynamics of the pipe system to corrupt the time delay estimate, which results in the leak being incorrectly located. In this paper, data from test-rigs in the United Kingdom and Canada are used to demonstrate this phenomenon, and analytical models of resonators are coupled with a pipe model to replicate the experimental results. The model is then used to investigate which of the two commonly used correlation algorithms, the Basic Cross-Correlation (BCC) function or the Phase Transform (PHAT), is more robust to the undesirable structural dynamics of the pipe system. It is found that time delay estimation is highly sensitive to the frequency bandwidth over which the analysis is conducted. Moreover, it is found that the PHAT is particularly sensitive to the presence of resonances and can give an incorrect time delay estimate, whereas the BCC function is found to be much more robust, giving a consistently accurate time delay estimate for a range of dynamic conditions.
Portable Microleak-Detection System
NASA Technical Reports Server (NTRS)
Rivers, H. Kevin; Sikora, Joseph G.; Sankaran, Sankara N.
2007-01-01
The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.
Leak detection by mass balance effective for Norman Wells line
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liou, J.C.P.
Mass-balance calculations for leak detection have been shown as effective as a leading software system, in a comparison based on a major Canadian crude-oil pipeline. The calculations and NovaCorp`s Leakstop software each detected 4% (approximately) or greater leaks on Interprovincial Pipe Line (IPL) Inc.`s Norman Wells pipeline. Insufficient data exist to assess performances of the two methods for leaks smaller than 4%. Pipeline leak detection using such software-based systems are common. Their effectiveness is measured by how small and how quickly a leak can be detected. Algorithms used and measurement uncertainties determine leak detectability.
NASA Astrophysics Data System (ADS)
de Vries, Jaap
2017-05-01
Adequate fire protection of distilled spirits stored in oak barrels requires understanding the failure mode of these barrels, including quantifying the leak rate. In this study, the use of a custom-calibrated, long-wave microbolometer camera is demonstrated to seek new protection methods for rack-stored distilled spirits. Individual oak barrels ranging between 200 L and 500 L filled with 75%/25% ethanol/water were exposed to both propane gas fires and pure ethanol pool fires. The IR camera was used to see through the smoke and flames showing the location of the leaks. The increase in HRR due to the leaked content was measured using gas calorimetry of the combustion products. This study showed that barrels leaked at a rate of approximately 4-8 lpm, resulting in heat release rates ranging between 1.2 and 2.4 MW. These numbers are confirmed by the quantitative measurements of gaseous H2O and CO¬2 in the exhaust. Surface temperature of the exposed oak could reach temperatures up to 750ºC.
NASA Astrophysics Data System (ADS)
Albertson, J. D.
2015-12-01
Methane emissions from underground pipeline leaks remain an ongoing issue in the development of accurate methane emission inventories for the natural gas supply chain. Application of mobile methods during routine street surveys would help address this issue, but there are large uncertainties in current approaches. In this paper, we describe results from a series of near-source (< 30 m) controlled methane releases where an instrumented van was used to measure methane concentrations during both fixed location sampling and during mobile traverses immediately downwind of the source. The measurements were used to evaluate the application of EPA Method 33A for estimating methane emissions downwind of a source and also to test the application of a new probabilistic approach for estimating emission rates from mobile traverse data.
Contal, Olivier; Vignaux, Laurence; Combescure, Christophe; Pepin, Jean-Louis; Jolliet, Philippe; Janssens, Jean-Paul
2012-02-01
Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Fleetwood, V A; Gross, K N; Alex, G C; Cortina, C S; Smolevitz, J B; Sarvepalli, S; Bakhsh, S R; Poirier, J; Myers, J A; Singer, M A; Orkin, B A
2017-03-01
Anastomotic leak (AL) increases costs and cancer recurrence. Studies show decreased AL with side-to-side stapled anastomosis (SSA), but none identify risk factors within SSAs. We hypothesized that stapler characteristics and closure technique of the common enterotomy affect AL rates. Retrospective review of bowel SSAs was performed. Data included stapler brand, staple line oversewing, and closure method (handsewn, HC; linear stapler [Barcelona technique], BT; transverse stapler, TX). Primary endpoint was AL. Statistical analysis included Fisher's test and logistic regression. 463 patients were identified, 58.5% BT, 21.2% HC, and 20.3% TX. Covidien staplers comprised 74.9%, Ethicon 18.1%. There were no differences between stapler types (Covidien 5.8%, Ethicon 6.0%). However, AL rates varied by common side closure (BT 3.7% vs. TX 10.6%, p = 0.017), remaining significant on multivariate analysis. Closure method of the common side impacts AL rates. Barcelona technique has fewer leaks than transverse stapled closure. Further prospective evaluation is recommended. Copyright © 2017. Published by Elsevier Inc.
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
40 CFR 1065.644 - Vacuum-decay leak rate.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak rate...
NASA Astrophysics Data System (ADS)
Nitheesh Kumar, P.; Khan, Vishwas Chandra; Balaganesan, G.; Pradhan, A. K.; Sivakumar, M. S.
2018-04-01
The present study is concerned with the repair of through thickness corrosion or leaking defects in metallic pipelines using a commercially available metallic seal and glass/epoxy composite. Pipe specimens are made with three different types of most commonly occurring through thickness corrosion/leaking defects. The metallic seal is applied over the through thickness corrosion/leaking defect and it is reinforced with glass/epoxy composite overwrap. The main objective of the metallic seal is to arrest the leak at live pressure. After reinforcing the metallic seal with glass/epoxy composite overwrap, the repaired composite wrap is able to sustain high pressures. Burst test is performed for different configurations of metallic seal and optimum configuration of metallic seal is determined. The optimum configurations of metallic seal for three different types of through thickness corrosion/leaking defects are further reinforced with glass/epoxy composite wrap and experimental failure pressure is determined by performing the burst test. An analytical model as per ISO 24817 has been developed to validate experimental results.
75 FR 76742 - Detecting Oil Leaks From Vessels Into the Water
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-09
... to detect leaks from oil tanks into the water? (E) What is the threshold for detection, accuracy... than leak detection from oil cargo tanks into the water? (H) Are methods or equipment being applied for... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2010-1085] Detecting Oil Leaks From...
Method for oil pipeline leak detection based on distributed fiber optic technology
NASA Astrophysics Data System (ADS)
Chen, Huabo; Tu, Yaqing; Luo, Ting
1998-08-01
Pipeline leak detection is a difficult problem to solve up to now. Some traditional leak detection methods have such problems as high rate of false alarm or missing detection, low location estimate capability. For the problems given above, a method for oil pipeline leak detection based on distributed optical fiber sensor with special coating is presented. The fiber's coating interacts with hydrocarbon molecules in oil, which alters the refractive indexed of the coating. Therefore the light-guiding properties of the fiber are modified. Thus pipeline leak location can be determined by OTDR. Oil pipeline lead detection system is designed based on the principle. The system has some features like real time, multi-point detection at the same time and high location accuracy. In the end, some factors that probably influence detection are analyzed and primary improving actions are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dawn Lenz; Raymond T. Lines; Darryl Murdock
ITT Industries Space Systems Division (Space Systems) has developed an airborne natural gas leak detection system designed to detect, image, quantify, and precisely locate leaks from natural gas transmission pipelines. This system is called the Airborne Natural Gas Emission Lidar (ANGEL) system. The ANGEL system uses a highly sensitive differential absorption Lidar technology to remotely detect pipeline leaks. The ANGEL System is operated from a fixed wing aircraft and includes automatic scanning, pointing system, and pilot guidance systems. During a pipeline inspection, the ANGEL system aircraft flies at an elevation of 1000 feet above the ground at speeds of betweenmore » 100 and 150 mph. Under this contract with DOE/NETL, Space Systems was funded to integrate the ANGEL sensor into a test aircraft and conduct a series of flight tests over a variety of test targets including simulated natural gas pipeline leaks. Following early tests in upstate New York in the summer of 2004, the ANGEL system was deployed to Casper, Wyoming to participate in a set of DOE-sponsored field tests at the Rocky Mountain Oilfield Testing Center (RMOTC). At RMOTC the Space Systems team completed integration of the system and flew an operational system for the first time. The ANGEL system flew 2 missions/day for the duration for the 5-day test. Over the course of the week the ANGEL System detected leaks ranging from 100 to 5,000 scfh.« less
Permeability After Impact Testing of Composite Laminates
NASA Technical Reports Server (NTRS)
Nettles, Alan T.
2003-01-01
Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a non-linear fashion for almost all of the specimens tested.
Permeability After Impact Testing of Composite Laminates
NASA Technical Reports Server (NTRS)
Nettles, A.T.; Munafo, Paul (Technical Monitor)
2002-01-01
Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a non-linear fashion for almost all of the specimens tested.
Experimental evaluation of a new system for laser tissue welding applied on damaged lungs.
Schiavon, Marco; Marulli, Giuseppe; Zuin, Andrea; Lunardi, Francesca; Villoresi, Paolo; Bonora, Stefano; Calabrese, Fiorella; Rea, Federico
2013-05-01
Alveolar air leaks represent a challenging problem in thoracic surgery, leading to increased patient morbidity and prolonged hospitalization. Several methods have been used, but no ideal technique exists yet. We investigated the lung-sealing capacity of an experimental kit for laser tissue welding. The kit is composed of a semiconductor laser system applied on a protein substrate associated with a chromophore that increases absorption. In vitro tests on porcine lung tissue were done to define ideal laser parameters (power 100 Å, frequency 50 Hz, pulse duration 400 µs) and protein substrate dilution (50%). For in vivo tests, through a left thoracotomy, 14 pigs received two different lung damages: a linear incision and a circular incision. Protein substrate applied on damaged areas was treated with laser to obtain a layer that reconstituted the integrity of the visceral pleura. Air leaks were intraoperatively evaluated by water submersion test with an airway pressure of 20 cmH2O. Animals were sacrificed at postoperative days 0 and 7 to study early and late pathological features. After applying laser treatment, no air leaks were seen in all proofs except in 2 cases in which a second application was required. At time 0, pathological damage mostly consisted of superficial alveolar necrotic tissue covered by protein membrane. At time 7, a complete recovery of lung lesions by fibrous scar with slight inflammatory reaction of adjacent lung tissue was seen. This experimental study demonstrated the effectiveness of laser tissue welding applied to seal air leaks after lung surgery. Further studies are needed to verify acceptability for human application.
Demonstration of rapid and sensitive module leak certification for space station freedom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, R.N.; Goodrich, R.W.
1991-03-01
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 {plus minus} 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 {plus minus} 0.7, {minus}0.4 {plus minus} 0.3, and 76 {plus minus} 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes formore » a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on {Delta}p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc. 13 refs.« less
Demonstration of rapid and sensitive module leak certification for Space Station Freedom
NASA Technical Reports Server (NTRS)
Dietz, R. N.; Goodrich, R. W.
1991-01-01
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 (+ or -) 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 (+ or -) 0.7, -0.4 (+ or -) 0.3, and 76 (+ or -) 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on (Delta)p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc.
Measuring Pinhole Leaks - A Novel Method
NASA Technical Reports Server (NTRS)
Dunn, Carol Anne
2009-01-01
Both of the shuttle pads have one of these large liquid hydrogen tanks and the Shuttle program is currently using both pads. However, just recently, there has been increasing concerns over possible air leaks from the outside into the evacuated region. A method to detect leaks involving measuring the change in the boil-off rate of the liquid hydrogen in the tank.
Water conservation study. Badger Army Ammunition Plant, Baraboo, Wisconsin. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-05-01
The purpose of this water conservation study is to identify projects which result in energy maintenance and cost savings in the process water distribution system at Badger Army Ammunition Plant (BAAP) in Baraboo, Wisconsin. A leak detection survey was performed on all process water piping with a diameter of 6 inches or greater. The leak detection analysis was performed using a combination of listening devices and preamplified-transducer systems to identify the majority of leak locations. When the location of the leak could not be readily identified using these methods, a leak correlator was used. The leak correlator determines leak locationmore » based on the time it takes for sound to travel from the leak to a waterline connection point.« less
Method for sealing remote leaks in an enclosure using an aerosol
Modera, Mark P.; Carrie, Francois R.
1999-01-01
The invention is a method and device for sealing leaks remotely by means of injecting a previously prepared aerosol into the enclosure being sealed according to a particular sealing efficiency defined by the product of a penetration efficiency and a particle deposition efficiency. By using different limits in the relationship between penetration efficiency and flowrate, the same method according the invention can be used for coating the inside of an enclosure. Specifically the invention is a method and device for preparing, transporting, and depositing a solid phase aerosol to the interior surface of the enclosure relating particle size, particle carrier flow rate, and pressure differential, so that particles deposited there can bridge and substantially seal each leak, with out providing a substantial coating at inside surfaces of the enclosure other than the leak. The particle size and flow parameters can be adjusted to coat the interior of the enclosure (duct) without substantial plugging of the leaks depending on how the particle size and flowrate relationships are chosen.
Measurement of Submerged Oil/Gas Leaks using ROV Video
NASA Astrophysics Data System (ADS)
Shaffer, Franklin; de Vera, Giorgio; Lee, Kenneth; Savas, Ömer
2013-11-01
Drilling for oil or gas in the Gulf of Mexico is increasing rapidly at depths up to three miles. The National Commission on the Deepwater Horizon Oil Leak concluded that inaccurate estimates of the leak rate from the Deepwater Horizon caused an inadequate response and attempts to cap the leak to fail. The first response to a submerged oil/gas leak will be to send a Remotely Operated Vehicle (ROV) down to view the leak. During the response to the Deepwater Horizon crisis, the authors Savas and Shaffer were members of the Flow Rate Technical Group's Plume Team who used ROV video to develop the FRTG's first official estimates of the oil leak rate. Savas and Shaffer developed an approach using the larger, faster jet features (e.g., turbulent eddies, vortices, entrained particles) in the near-field developing zone to measure discharge rates. The authors have since used the Berkeley Tow Tank to test this approach on submerged dye-colored water jets and compressed air jets. Image Correlation Velocimetry has been applied to measure the velocity of visible features. Results from tests in the Berkeley Tow Tank and submerged oil jets in the OHMSETT facility will be presented.
Reusable Solid Rocket Motor Nozzle Joint-4 Thermal Analysis
NASA Technical Reports Server (NTRS)
Clayton, J. Louie
2001-01-01
This study provides for development and test verification of a thermal model used for prediction of joint heating environments, structural temperatures and seal erosions in the Space Shuttle Reusable Solid Rocket Motor (RSRM) Nozzle Joint-4. The heating environments are a result of rapid pressurization of the joint free volume assuming a leak path has occurred in the filler material used for assembly gap close out. Combustion gases flow along the leak path from nozzle environment to joint O-ring gland resulting in local heating to the metal housing and erosion of seal materials. Analysis of this condition was based on usage of the NASA Joint Pressurization Routine (JPR) for environment determination and the Systems Improved Numerical Differencing Analyzer (SINDA) for structural temperature prediction. Model generated temperatures, pressures and seal erosions are compared to hot fire test data for several different leak path situations. Investigated in the hot fire test program were nozzle joint-4 O-ring erosion sensitivities to leak path width in both open and confined joint geometries. Model predictions were in generally good agreement with the test data for the confined leak path cases. Worst case flight predictions are provided using the test-calibrated model. Analysis issues are discussed based on model calibration procedures.
Xiong, Hui; Sultan, Laith R; Cary, Theodore W; Schultz, Susan M; Bouzghar, Ghizlane; Sehgal, Chandra M
2017-05-01
To assess the diagnostic performance of a leak-plugging segmentation method that we have developed for delineating breast masses on ultrasound images. Fifty-two biopsy-proven breast lesion images were analyzed by three observers using the leak-plugging and manual segmentation methods. From each segmentation method, grayscale and morphological features were extracted and classified as malignant or benign by logistic regression analysis. The performance of leak-plugging and manual segmentations was compared by: size of the lesion, overlap area ( O a ) between the margins, and area under the ROC curves ( A z ). The lesion size from leak-plugging segmentation correlated closely with that from manual tracing ( R 2 of 0.91). O a was higher for leak plugging, 0.92 ± 0.01 and 0.86 ± 0.06 for benign and malignant masses, respectively, compared to 0.80 ± 0.04 and 0.73 ± 0.02 for manual tracings. Overall O a between leak-plugging and manual segmentations was 0.79 ± 0.14 for benign and 0.73 ± 0.14 for malignant lesions. A z for leak plugging was consistently higher (0.910 ± 0.003) compared to 0.888 ± 0.012 for manual tracings. The coefficient of variation of A z between three observers was 0.29% for leak plugging compared to 1.3% for manual tracings. The diagnostic performance, size measurements, and observer variability for automated leak-plugging segmentations were either comparable to or better than those of manual tracings.
40 CFR 63.1036 - Alternative means of emission limitation: Batch processes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 2 Standards... leaks. The owner or operator may switch among the alternatives provided the change is documented as... shall be pressure-tested for leaks before regulated material is first fed to the equipment and the...
Silver plating technique seals leaks in thin wall tubing joints
NASA Technical Reports Server (NTRS)
Blenderman, W. H.
1966-01-01
Leaks in thin wall tubing joints are sealed by cleaning and silver plating the hot gas side of the joint in the leakage area. The pressure differential across the silver during hydrostatic test and subsequent use forces the ductile silver into the leak area and seals it.
DOE Office of Scientific and Technical Information (OSTI.GOV)
HAMMERS, J.S.
The purpose of the test was to verify that the AN Tank Farm B Pit Leak Detector components are functionally integrated and operate in accordance with engineering design specifications. The Acceptance Test Procedure HNF-4646,241-AN-B-Pit Leak Detection ANB-WT-LDSTA-231 was conducted between 26 June and 02 July 1999 at the 200E AN Tank Farm. The test has been completed with no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed this had no impact on the procedure or test results. All components, identified in the procedure were found to be labeled and identified as writtenmore » in the procedure.« less
Experiences with leak rate calculations methods for LBB application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grebner, H.; Kastner, W.; Hoefler, A.
1997-04-01
In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.
Bentham, James; English, Kate; Hares, Dominic; Gibbs, John; Thomson, John
2012-10-01
The aim of this study was to describe the clinical importance and methods of transcatheter closure of systemic venous baffle leaks after atrial redirection procedures for transposed great vessels. Until the late 1970s, atrial redirection surgery was the principal surgical palliative approach to manage transposed great vessels. Baffle leaks are among the many long-term complications of this type of surgery, and their prevalence increases over time. The clinical consequences of baffle leaks in this population are poorly understood, and the indications for closure are incompletely defined. During outpatient follow-up of 126 patients after atrial redirection surgery, 15 baffle leaks were detected in 11 patients. All underwent transcatheter closure using either an occluding device or a covered stent if there was concomitant baffle obstruction. The average age at the time of the procedure was 26 years (range 6 to 42). Ten of 11 patients were cyanosed at rest or on a simple walk test (median oxygen saturation level 80%, range 65% to 96%). Six of 11 patients were polycythemic before leak closure (median hemoglobin concentration 19 g/dl, range 13.8 to 23). After closure, there was a significant improvement in saturation (median 97%, p <0.0001) and a significant reduction in hemoglobin concentration at 6 months after the procedure (median 14.8 g/dl, p <0.05). There were no procedural adverse events. One patient experienced late device embolization necessitating surgical removal. In conclusion, transcatheter closure of baffle leaks is a technically feasible although frequently complex and lengthy procedure. Closure is associated with an improvement in oxygen saturations and a reduction in polycythaemia. Copyright © 2012 Elsevier Inc. All rights reserved.
A Hydrogen Leak Detection System for Aerospace and Commercial Applications
NASA Technical Reports Server (NTRS)
Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.
1995-01-01
Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.
Leak Rate Performance of Silicone Elastomer O-Rings Contaminated with JSC-1A Lunar Regolith Simulant
NASA Technical Reports Server (NTRS)
Oravec, Heather Ann; Daniels, Christopher C.
2014-01-01
Contamination of spacecraft components with planetary and foreign object debris is a growing concern. Face seals separating the spacecraft cabin from the debris filled environment are particularly susceptible; if the seal becomes contaminated there is potential for decreased performance, mission failure, or catastrophe. In this study, silicone elastomer O-rings were contaminated with JSC- 1A lunar regolith and their leak rate performance was evaluated. The leak rate values of contaminated O-rings at four levels of seal compression were compared to those of as-received, uncontaminated, O-rings. The results showed a drastic increase in leak rate after contamination. JSC-1A contaminated O-rings lead to immeasurably high leak rate values for all levels of compression except complete closure. Additionally, a mechanical method of simulant removal was examined. In general, this method returned the leak rate to as-received values.
Leak detection in gas pipeline by acoustic and signal processing - A review
NASA Astrophysics Data System (ADS)
Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.
2015-12-01
The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.
GPR-Based Water Leak Models in Water Distribution Systems
Ayala-Cabrera, David; Herrera, Manuel; Izquierdo, Joaquín; Ocaña-Levario, Silvia J.; Pérez-García, Rafael
2013-01-01
This paper addresses the problem of leakage in water distribution systems through the use of ground penetrating radar (GPR) as a nondestructive method. Laboratory tests are performed to extract features of water leakage from the obtained GPR images. Moreover, a test in a real-world urban system under real conditions is performed. Feature extraction is performed by interpreting GPR images with the support of a pre-processing methodology based on an appropriate combination of statistical methods and multi-agent systems. The results of these tests are presented, interpreted, analyzed and discussed in this paper.
105-KE Isolation Barrier Leak Rate Acceptance Test Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCracken, K.J.
1995-06-14
This Acceptance Test Report (ATR) contains the completed and signed Acceptance Procedure (ATP) for the 105-KE Isolations Barrier Leak Rate Test. The Test Engineer`s log, the completed sections of the ATP in the Appendix for Repeat Testing (Appendix K), the approved WHC J-7s (Appendix H), the data logger files (Appendices T and U), and the post test calibration checks (Appendix V) are included.
Thermal shock testing for assuring reliability of glass-sealed microelectronic packages
NASA Technical Reports Server (NTRS)
Thomas, Walter B., III; Lewis, Michael D.
1991-01-01
Tests were performed to determine if thermal shocking is destructive to glass-to-metal seal microelectronic packages and if thermal shock step stressing can compare package reliabilities. Thermal shocking was shown to be not destructive to highly reliable glass seals. Pin-pull tests used to compare the interfacial pin glass strengths showed no differences between thermal shocked and not-thermal shocked headers. A 'critical stress resistance temperature' was not exhibited by the 14 pin Dual In-line Package (DIP) headers evaluated. Headers manufactured in cryogenic nitrogen based and exothermically generated atmospheres showed differences in as-received leak rates, residual oxide depths and pin glass interfacial strengths; these were caused by the different manufacturing methods, in particular, by the chemically etched pins used by one manufacturer. Both header types passed thermal shock tests to temperature differentials of 646 C. The sensitivity of helium leak rate measurements was improved up to 70 percent by baking headers for two hours at 200 C after thermal shocking.
Preliminary study of the use of radiotracers for leak detection in industrial applications
NASA Astrophysics Data System (ADS)
Wetchagarun, S.; Petchrak, A.; Tippayakul, C.
2015-05-01
One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaech, J.L.
The use of a pooling technique in leak testing Plutonium Recycle Test Reactor fuel elements to reduce the number of tests is discussed. Since the proportion of defectives in this case is small, application of the method would suggest that the group size be large. It was suggested that additional savings might be introduced by subgrouping the originally grouped items in the event of a positive result, rather than testing them individually. An investigation was made to determine optimum subgrouping sizes. (M.C.G.)
Postoperative air leak grading is useful to predict prolonged air leak after pulmonary lobectomy.
Oh, Sang Gi; Jung, Yochun; Jheon, Sanghoon; Choi, Yunhee; Yun, Ju Sik; Na, Kook Joo; Ahn, Byoung Hee
2017-01-23
Results of studies to predict prolonged air leak (PAL; air leak longer than 5 days) after pulmonary lobectomy have been inconsistent and are of limited use. We developed a new scale representing the amount of early postoperative air leak and determined its correlation with air leak duration and its potential as a predictor of PAL. We grade postoperative air leak using a 5-grade scale. All 779 lobectomies from January 2005 to December 2009 with available medical records were reviewed retrospectively. We devised six 'SUM' variables using air leak grades in the initial 72 h postoperatively. Excluding unrecorded cases and postoperative broncho-pleural fistulas, there were 720 lobectomies. PAL occurred in 135 cases (18.8%). Correlation analyses showed each SUM variable highly correlated with air leak duration, and the SUM 4to9 , which was the sum of six consecutive values of air leak grades for every 8 h record on postoperative days 2 and 3, was proved to be the most powerful predictor of PAL; PAL could be predicted with 75.7% and 77.7% positive and negative predictive value, respectively, when SUM 4to9 ≥ 16. When 4 predictors derived from multivariable logistic regression of perioperative variables were combined with SUM 4to9 , there was no significant increase in predictability compared with SUM 4to9 alone. This simple new method to predict PAL using SUM 4to9 showed that the amount of early postoperative air leak is the most powerful predictor of PAL, therefore, grading air leak after pulmonary lobectomy is a useful method to predict PAL.
Superfluid helium leak sealant study
NASA Technical Reports Server (NTRS)
Vorreiter, J. W.
1981-01-01
Twenty-one leak specimens were fabricated in the ends of stainless steel and aluminum tubes. Eighteen of these tubes were coated with a copolymer material to seal the leak. The other three specimens were left uncoated and served as control specimens. All 21 tubes were cold shocked in liquid helium 50 times and then the leak rate was measured while the tubes were submerged in superfluid helium at 1.7 K. During the cold shocks two of the coated specimens were mechanically damaged and eliminated from the test program. Of the remaining 16 coated specimens one suffered a total coating failure and resulting high leak rate. Another three of the coated specimens suffered partial coating failures. The leak rates of the uncoated specimens were also measured and reported. The significance of various leak rates is discussed in view of the infrared astronomical satellite (IRAS) Dewar performance.
Annular Air Leaks in a liquid hydrogen storage tank
NASA Astrophysics Data System (ADS)
Krenn, AG; Youngquist, RC; Starr, SO
2017-12-01
Large liquid hydrogen (LH2) storage tanks are vital infrastructure for NASA, the DOD, and industrial users. Over time, air may leak into the evacuated, perlite filled annular region of these tanks. Once inside, the extremely low temperatures will cause most of the air to freeze. If a significant mass of air is allowed to accumulate, severe damage can result from nominal draining operations. Collection of liquid air on the outer shell may chill it below its ductility range, resulting in fracture. Testing and analysis to quantify the thermal conductivity of perlite that has nitrogen frozen into its interstitial spaces and to determine the void fraction of frozen nitrogen within a perlite/frozen nitrogen mixture is presented. General equations to evaluate methods for removing frozen air, while avoiding fracture, are developed. A hypothetical leak is imposed on an existing tank geometry and a full analysis of that leak is detailed. This analysis includes a thermal model of the tank and a time-to-failure calculation. Approaches to safely remove the frozen air are analyzed, leading to the conclusion that the most feasible approach is to allow the frozen air to melt and to use a water stream to prevent the outer shell from chilling.
Pressure Decay Testing Methodology for Quantifying Leak Rates of Full-Scale Docking System Seals
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.; Daniels, Christopher C.; Wasowski, Janice L.; Garafolo, Nicholas G.; Penney, Nicholas; Steinetz, Bruce M.
2010-01-01
NASA is developing a new docking system to support future space exploration missions to low-Earth orbit and the Moon. This system, called the Low Impact Docking System, is a mechanism designed to connect the Orion Crew Exploration Vehicle to the International Space Station, the lunar lander (Altair), and other future Constellation Project vehicles. NASA Glenn Research Center is playing a key role in developing the main interface seal for this docking system. This seal will be relatively large with an outside diameter in the range of 54 to 58 in. (137 to 147 cm). As part of this effort, a new test apparatus has been designed, fabricated, and installed to measure leak rates of candidate full-scale seals under simulated thermal, vacuum, and engagement conditions. Using this test apparatus, a pressure decay testing and data processing methodology has been developed to quantify full-scale seal leak rates. Tests performed on untreated 54 in. diameter seals at room temperature in a fully compressed state resulted in leak rates lower than the requirement of less than 0.0025 lbm, air per day (0.0011 kg/day).
VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME II: APPENDICES A-E
The program of experiments conducted at Griffiss Air Force Base was devised to expand the understanding of large underground storage tank behavior as it impacts the performance of volumetric leak detection testing. The report addresses three important questions about testing the ...
40 CFR 63.945 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the... devices shall be secured in the closed position. (3) The detection instrument shall meet the performance... material placed in the unit, not for each individual organic constituent. (4) The detection instrument...
REACTOR FUEL ELEMENTS TESTING CONTAINER
Whitham, G.K.; Smith, R.R.
1963-01-15
This patent shows a method for detecting leaks in jacketed fuel elements. The element is placed in a sealed tank within a nuclear reactor, and, while the reactor operates, the element is sparged with gas. The gas is then led outside the reactor and monitored for radioactive Xe or Kr. (AEC)
Simonetti, Andrea; Amari, Filippo
2015-01-01
In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical solution, preventing possible prefilled syringe plunger movement during container closure integrity testing execution, is presented as well. The growing need to meet sterile drug products' regulatory, quality, and safety expectations has progressively driven new developments and improvements both in container closure integrity testing methods and in the respective equipment, over the last years. Indeed, container closure integrity testing establishes the container closure system capability to provide required protection to the drug product and to demonstrate maintenance of product sterility over its shelf life. This article describes the development of four container closure integrity testing approaches for the evaluation of glass prefilled syringe closure integrity, including two destructive (pharmacopoeial and Novartis specific dye ingress test) and two non-destructive (vacuum decay and high-voltage leak detection) methods. The important finding from the validation of comparative studies was that the vacuum decay method resulted in the most effective, reliable and repeatable detection of defective samples, whether the defect was exposed to sterile water, to drug product, or to air. Complete sets of known defects were created for this purpose (5 μm, 10 μm, 20 μm certified leakages by laser drilled holes and capillary tubes). All investigations and studies were conducted at Bonfiglioli Engineering S.r.l. (Vigarano Pieve, Ferrara, Italy) and at Novartis Vaccines (Sovicille, Siena, Italy). © PDA, Inc. 2015.
METHODOLOGY TO EVALUATE THE POTENTIAL FOR GROUND WATER CONTAMINATION FROM GEOTHERMAL FLUID RELEASES
This report provides analytical methods and graphical techniques to predict potential ground water contamination from geothermal energy development. Overflows and leaks from ponds, pipe leaks, well blowouts, leaks from well casing, and migration from injection zones can be handle...
40 CFR 265.191 - Assessment of existing tank system's integrity.
Code of Federal Regulations, 2010 CFR
2010-07-01
...); and (5) Results of a leak test, internal inspection, or other tank integrity examination such that: (i) For non-enterable underground tanks, this assessment must consist of a leak test that is capable of... water table effects, (ii) For other than non-enterable underground tanks and for ancillary equipment...
40 CFR 264.191 - Assessment of existing tank system's integrity.
Code of Federal Regulations, 2010 CFR
2010-07-01
...); and (5) Results of a leak test, internal inspection, or other tank integrity examination such that: (i) For non-enterable underground tanks, the assessment must include a leak test that is capable of taking into account the effects of temperature variations, tank end deflection, vapor pockets, and high water...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Boyun; Duguid, Andrew; Nygaard, Ronar
The objective of this project is to develop a computerized statistical model with the Integrated Neural-Genetic Algorithm (INGA) for predicting the probability of long-term leak of wells in CO 2 sequestration operations. This object has been accomplished by conducting research in three phases: 1) data mining of CO 2-explosed wells, 2) INGA computer model development, and 3) evaluation of the predictive performance of the computer model with data from field tests. Data mining was conducted for 510 wells in two CO 2 sequestration projects in the Texas Gulf Coast region. They are the Hasting West field and Oyster Bayou fieldmore » in the Southern Texas. Missing wellbore integrity data were estimated using an analytical and Finite Element Method (FEM) model. The INGA was first tested for performances of convergence and computing efficiency with the obtained data set of high dimension. It was concluded that the INGA can handle the gathered data set with good accuracy and reasonable computing time after a reduction of dimension with a grouping mechanism. A computerized statistical model with the INGA was then developed based on data pre-processing and grouping. Comprehensive training and testing of the model were carried out to ensure that the model is accurate and efficient enough for predicting the probability of long-term leak of wells in CO 2 sequestration operations. The Cranfield in the southern Mississippi was select as the test site. Observation wells CFU31F2 and CFU31F3 were used for pressure-testing, formation-logging, and cement-sampling. Tools run in the wells include Isolation Scanner, Slim Cement Mapping Tool (SCMT), Cased Hole Formation Dynamics Tester (CHDT), and Mechanical Sidewall Coring Tool (MSCT). Analyses of the obtained data indicate no leak of CO 2 cross the cap zone while it is evident that the well cement sheath was invaded by the CO 2 from the storage zone. This observation is consistent with the result predicted by the INGA model which indicates the well has a CO 2 leak-safe probability of 72%. This comparison implies that the developed INGA model is valid for future use in predicting well leak probability.« less
Leak locating microphone, method and system for locating fluid leaks in pipes
Kupperman, David S.; Spevak, Lev
1994-01-01
A leak detecting microphone inserted directly into fluid within a pipe includes a housing having a first end being inserted within the pipe and a second opposed end extending outside the pipe. A diaphragm is mounted within the first housing end and an acoustic transducer is coupled to the diaphragm for converting acoustical signals to electrical signals. A plurality of apertures are provided in the housing first end, the apertures located both above and below the diaphragm, whereby to equalize fluid pressure on either side of the diaphragm. A leak locating system and method are provided for locating fluid leaks within a pipe. A first microphone is installed within fluid in the pipe at a first selected location and sound is detected at the first location. A second microphone is installed within fluid in the pipe at a second selected location and sound is detected at the second location. A cross-correlation is identified between the detected sound at the first and second locations for identifying a leak location.
Leak detectability of the Norman Wells pipeline by mass balance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liou, J.C.P.
Pipeline leak detection using software-based systems is becoming common practice. The detectability of such systems is measured by how small and how quickly a leak can be detected. Algorithms used and measurement uncertainties determine leak detectability. This paper addresses leak detectability using mass balance, establishes leak detectability for Norman Wells pipelines, and compares it with field leak test results. The pipeline is operated by the Interprovincial Pipe Line (IPL) Inc., of Edmonton, Canada. It is a 12.75-inch outside diameter steel pipe with variable wall thickness. The length of the pipe is approximately 550 miles (868.9 km). The pipeline transports lightmore » crude oil at a constant flow rate of about 250 m{sup 3}/hr. The crude oil can enter the pipeline at two locations. Besides the Norman Wells inlet, there is a side line near Zama terminal that can inject crude oil into the pipeline.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... until the leak check is passed. Post-test leak check ≤4% of average sampling rate After sampling ** See... the test site. The sorbent media must be obtained from a source that can demonstrate the quality...-traceable calibration gas standards and reagents shall be used for the tests and procedures required under...
Gas Leak Detection by Dilution of Atmospheric Oxygen
Lambrecht, Armin; Maier, Eric; Strahl, Thomas; Herbst, Johannes
2017-01-01
Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2. PMID:29206133
Fibrin glue as agent for sealing corneal and conjunctival wound leaks.
Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S
2018-02-01
PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.
Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berg, John M.
Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gasmore » composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10 -7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10 -7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10 -5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10 -5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10 -7 std cc/sec.« less
Testing of Prototype Magnetic Suspension Cryogenic Transfer Line
NASA Astrophysics Data System (ADS)
Fesmire, J. E.; Augustynowicz, S. D.; Nagy, Z. F.; Sojourner, S. J.; Shu, Q. S.; Cheng, G.; Susta, J. T.
2006-04-01
A 6-meter prototype cryogenic transfer line with magnetic suspension was tested for its mechanical and thermal performance at the Cryogenics Test Laboratory of NASA Kennedy Space Center (KSC). A test facility with two cryogenic end-boxes was designed and commissioned for the testing. Suspension mechanisms were verified through a series of tests with liquid nitrogen. The thermal performance of the prototype was determined using the new test apparatus. The tested prototype has incorporated temperature and vacuum pressure data acquisition ports, customized interfaces to cryogenic end-boxes, and instrumentation. All tests were conducted under simulated onsite transfer line working conditions. A static (boiloff rate measurement) testing method was employed to demonstrate the gross heat leak in the tested article. The real-time temperature distribution, vacuum level, levitation distance, and mass flow rate were measured. The main purpose of this paper is to summarize the testing facility design and preparation, test procedure, and primary test results. Special arrangements (such as turning on/off mechanical support units, observing levitation gap, and setting up the flowmeter) in testing of such a magnetically levitated transfer line are also discussed. Preliminary results show that the heat leak reduction of approximately one-third to one-half is achievable through such transfer lines with a magnetic suspension system.
Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Miller, Jennifer R.; Birur, Gajanana; Bame, David; Mastropietro, A. J.; Bhandari, Pradeep; Lee, Darlene; Karlmann, Paul; Liu, Yuanming
2013-01-01
Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.
Salusjärvi, Johannes M; Carpelan-Holmström, Monika A; Louhimo, Johanna M; Kruuna, Olli; Scheinin, Tom M
2018-03-01
An anastomotic leak is a fairly common and a potentially lethal complication in colorectal surgery. Objective methods to assess the viability and blood circulation of the anastomosis could help in preventing leaks. Intraoperative pulse oximetry is a cheap, easy to use, fast, and readily available method to assess tissue viability. Our aim was to study whether intraoperative pulse oximetry can predict the development of an anastomotic leak. The study was a prospective single-arm study conducted between the years 2005 and 2011 in Helsinki University Hospital. Patient material consisted of 422 patients undergoing elective left-sided colorectal surgery. The patients were operated by one of the three surgeons. All of the operations were partial or total resections of the left side of the colon with a colorectal anastomosis. The intraoperative colonic oxygen saturation was measured with pulse oximetry from the colonic wall, and the values were analyzed with respect to post-operative complications. 2.3 times more operated anastomotic leaks occurred when the colonic StO 2 was ≤ 90% (11/129 vs 11/293). The mean colonic StO 2 was 91.1 in patients who developed an operated anastomotic leak and 93.0 in patients who did not. With logistic regression analysis, the risk of operated anastomotic leak was 4.2 times higher with StO 2 values ≤ 90%. Low intraoperative colonic StO 2 values are associated with the occurrence of anastomotic leak. Despite its handicaps, the method seems to be useful in assessing anastomotic viability.
Lei, Zhipeng; Yang, James; Zhuang, Ziqing; Roberge, Raymond
2013-05-01
This paper presents a computational fluid dynamics (CFD) simulation approach for the prediction of leakage between an N95 filtering facepiece respirator (FFR) and a headform and an infrared camera (IRC) method for validating the CFD approach. The CFD method was used to calculate leak location(s) and 'filter-to-faceseal leakage' (FTFL) ratio for 10 headforms and 6 FFRs.The computational geometry and leak gaps were determined from analysis of the contact simulation results between each headform-N95 FFR combination. The volumetric mesh was formed using a mesh generation method developed by the authors. The breathing cycle was described as a time-dependent profile of the air velocity through the nostril. Breathing air passes through both the FFR filter medium and the leak gaps. These leak gaps are the areas failing to achieve a seal around the circumference of the FFR. The CFD approach was validated by comparing facial temperatures and leak sites from IRC measurements with eight human subjects. Most leaks appear at the regions of the nose (40%) and right (26%) and left cheek (26%) sites. The results also showed that, with N95 FFR (no exhalation valves) use, there was an increase in the skin temperature at the region near the lip, which may be related to thermal discomfort. The breathing velocity and the viscous resistance coefficient of the FFR filter medium directly impacted the FTFL ratio, while the freestream flow did not show any impact on the FTFL ratio. The proposed CFD approach is a promising alternative method to study FFR leakage if limitations can be overcome.
Hermetic edge sealing of photovoltaic modules
NASA Astrophysics Data System (ADS)
1983-02-01
The edge sealing technique is accomplished by a combination of a chemical bond between glass and aluminum, formed by electrostatic bonding, and a metallurgical bond between aluminum and aluminum, formed by ultrasonic welding. Such a glass to metal seal promises to provide a low cost, long lifetime, highly effective hermetic seal which can protect module components from severe environments. Development of the sealing techniques and demonstration of their effectiveness by fabricating a small number of dummy modules, up to eight inches square in size, and testing them for hermeticity using helium leak testing methods are reviewed. Non-destructive test methods are investigated.
Hermetic edge sealing of photovoltaic modules
NASA Technical Reports Server (NTRS)
1983-01-01
The edge sealing technique is accomplished by a combination of a chemical bond between glass and aluminum, formed by electrostatic bonding, and a metallurgical bond between aluminum and aluminum, formed by ultrasonic welding. Such a glass to metal seal promises to provide a low cost, long lifetime, highly effective hermetic seal which can protect module components from severe environments. Development of the sealing techniques and demonstration of their effectiveness by fabricating a small number of dummy modules, up to eight inches square in size, and testing them for hermeticity using helium leak testing methods are reviewed. Non-destructive test methods are investigated.
Permeability Testing of Impacted Composite Laminates for Use on Reusable Launch Vehicles
NASA Technical Reports Server (NTRS)
Nettles, A. T.
2001-01-01
Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite, and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented, and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a nonlinear fashion for almost all the specimens tested.
40 CFR 65.120 - Reporting provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.120 Reporting provisions. (a) Initial Compliance Status... equipment in vacuum service; and (iii) Method of compliance with the standard (for example, “monthly leak... in a summary format by equipment type the number of components for which leaks were detected, and for...
40 CFR 61.135 - Standard: Equipment leaks.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emissions from Coke By-Product Recovery Plants § 61.135 Standard: Equipment leaks. (a) Each owner or... benzene service. (d) Each exhauster shall be monitored quarterly to detect leaks by the methods specified... stuffing box pressure; or (ii) Equipped with a barrier fluid system that is connected by a closed vent...
10 CFR 32.59 - Same: Leak testing of each source.
Code of Federal Regulations, 2012 CFR
2012-01-01
... kilobecquerels (0.1 microcurie) of americium-241 or radium-226 before transferring the source to a general....185 kilobecquerel (0.005 microcurie) of americium-241 or radium-226. If this test discloses more than... leaking or losing americium-241 or radium-226 and shall not be transferred to a general licensee under...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swain, M.R.
The following report is divided into two sections. The first section describes the results of ignitability tests of high pressure hydrogen and natural gas leaks. The volume of ignitable gases formed by leaking hydrogen or natural gas were measured. Leaking high pressure hydrogen produced a cone of ignitable gases with 28{degrees} included angle. Leaking high pressure methane produced a cone of ignitable gases with 20{degrees} included angle. Ignition of hydrogen produced larger overpressures than did natural gas. The largest overpressures produced by hydrogen were the same as overpressures produced by inflating a 11 inch child`s balloon until it burst.
NASA Astrophysics Data System (ADS)
Hastings, Leon J.; Martin, James J.
1998-01-01
An 18-m3 system-level test bed termed the Multipurpose Hydrogen Test Bed (MHTB has been used to evaluate a foam/multilayer combination insulation concept. The foam element (Isofoam SS-1171) protects against ground hold/ascent flight environments, and allows the use of dry nitrogen purge as opposed to a more complex/heavy helium purge subsystem. The MLI (45 layers of Double Aluminized Mylar with Dacron spacers) is designed for an on-orbit storage period of 45 days. Unique MLI features included; a variable layer density (reduces weight and radiation losses), larger but fewer DAM vent perforations (reduces radiation losses), and a roll wrap installation which resulted in a very robust MLI and reduced both assembly man-hours and seam heat leak. Ground hold testing resulted in an average heat leak of 63 W/m2 and purge gas liquefaction was successfully prevented. The orbit hold simulation produced a heat leak of 0.22 W/m2 with 305 K boundary which, compared to historical data, represents a 50-percent heat leak reduction.
The mechanical and microbiological integrity of surgical gloves.
Jamal, Ala; Wilkinson, Stephen
2003-03-01
Several manufacturers supply surgical gloves that have been individually tested (IT) for leaks. Other manufacturers supply gloves in which sample gloves from each batch are tested for leaks (batch tested: BT). The latter brands may be rejected by surgeons because of presumed increased risk of wound infection and staff exposure to patient pathogens. The influence of differences between glove brands on performance in surgery has not been extensively studied. The aims of the present study were to test the mechanical and microbiological integrity of IT compared to BT gloves. A total of 110 unused gloves from each of an IT and a BT brand were tested for leaks, first, by observation of water-jets from water-filled gloves and second, by measuring electrical resistance between inside and outside the glove surfaces, to give a baseline measure. A total of 304 IT and 280 BT gloves were then similarly leak-tested after 98 clean surgical procedures. The hands and gloves of scrub team members were cultured postsurgery. A total of 1/110 BT and 0/110 IT unused gloves contained leaks (NS, Fisher's exact test). Operative perforation rates were lower for BT compared with IT (8/280 cf. 22/304; P < 0.05 Fisher's exact test). There was no bias in types of operations or scrub team members to account for the difference. Growth of normal skin flora was found on virtually every wearer's hands post-operatively. Similar bacteria were frequently cultured from the outside of gloves at the conclusion of surgery (111/152 pairs IT cf. 122/140 pairs BT; P < 0.01, Fisher's exact test). This study provides evidence that the clinical performance of BT gloves is no different to IT gloves. There was no significant difference in mechanical leak rates for unused gloves. Paradoxically, although IT gloves were more likely to show macro-perforations after surgery, the incidence of contamination on the surface of BT gloves was greater, possibly reflecting a qualitative difference in glove material. This study suggests that both types of gloves develop microporosity during use, which may allow transfer of bacteria from the surgeon's skin to the surface of the glove.
Research on distributed optical fiber sensing data processing method based on LabVIEW
NASA Astrophysics Data System (ADS)
Li, Zhonghu; Yang, Meifang; Wang, Luling; Wang, Jinming; Yan, Junhong; Zuo, Jing
2018-01-01
The pipeline leak detection and leak location problem have gotten extensive attention in the industry. In this paper, the distributed optical fiber sensing system is designed based on the heat supply pipeline. The data processing method of distributed optical fiber sensing based on LabVIEW is studied emphatically. The hardware system includes laser, sensing optical fiber, wavelength division multiplexer, photoelectric detector, data acquisition card and computer etc. The software system is developed using LabVIEW. The software system adopts wavelet denoising method to deal with the temperature information, which improved the SNR. By extracting the characteristic value of the fiber temperature information, the system can realize the functions of temperature measurement, leak location and measurement signal storage and inquiry etc. Compared with traditional negative pressure wave method or acoustic signal method, the distributed optical fiber temperature measuring system can measure several temperatures in one measurement and locate the leak point accurately. It has a broad application prospect.
Probabilistic pipe fracture evaluations for leak-rate-detection applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, S.; Ghadiali, N.; Paul, D.
1995-04-01
Regulatory Guide 1.45, {open_quotes}Reactor Coolant Pressure Boundary Leakage Detection Systems,{close_quotes} was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, {open_quotes}Leak Before Break Evaluation Procedures{close_quotes} where a margin of 10 on the leak detection limit is used in determining the crackmore » size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break.« less
40 CFR 258.41 - Project XL Bioreactor Landfill Projects.
Code of Federal Regulations, 2010 CFR
2010-07-01
... footprint of the landfill cell. (B) Water collected on the leak detection liner shall be monitored at least... this section is leachate or gas condensate derived from the MSWLF, which may be supplemented with water... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and...
Improving Quality of Seal Leak Test Product using Six Sigma
NASA Astrophysics Data System (ADS)
Luthfi Malik, Abdullah; Akbar, Muhammad; Irianto, Dradjad
2016-02-01
Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure.
Development of a low cost unmanned aircraft system for atmospheric carbon dioxide leak detection
NASA Astrophysics Data System (ADS)
Mitchell, Taylor Austin
Carbon sequestration, the storage of carbon dioxide gas underground, has the potential to reduce global warming by removing a greenhouse gas from the atmosphere. These storage sites, however, must first be monitored to detect if carbon dioxide is leaking back out to the atmosphere. As an alternative to traditional large ground-based sensor networks to monitor CO2 levels for leaks, unmanned aircraft offer the potential to perform in-situ atmospheric leak detection over large areas for a fraction of the cost. This project developed a proof-of-concept sensor system to map relative carbon dioxide levels to detect potential leaks. The sensor system included a Sensair K-30 FR CO2 sensor, GPS, and altimeter connected an Arduino microcontroller which logged data to an onboard SD card. Ground tests were performed to verify and calibrate the system including wind tunnel tests to determine the optimal configuration of the system for the quickest response time (4-8 seconds based upon flowrate). Tests were then conducted over a controlled release of CO 2 in addition to over controlled rangeland fires which released carbon dioxide over a large area as would be expected from a carbon sequestration source. 3D maps of carbon dioxide were developed from the system telemetry that clearly illustrated increased CO2 levels from the fires. These tests demonstrated the system's ability to detect increased carbon dioxide concentrations in the atmosphere.
Development of an Advanced Respirator Fit-Test Headform
Bergman, Michael S.; Zhuang, Ziqing; Hanson, David; Heimbuch, Brian K.; McDonald, Michael J.; Palmiero, Andrew J.; Shaffer, Ronald E.; Harnish, Delbert; Husband, Michael; Wander, Joseph D.
2015-01-01
Improved respirator test headforms are needed to measure the fit of N95 filtering facepiece respirators (FFRs) for protection studies against viable airborne particles. A Static (i.e., non-moving, non-speaking) Advanced Headform (StAH) was developed for evaluating the fit of N95 FFRs. The StAH was developed based on the anthropometric dimensions of a digital headform reported by the National Institute for Occupational Safety and Health (NIOSH) and has a silicone polymer skin with defined local tissue thicknesses. Quantitative fit factor evaluations were performed on seven N95 FFR models of various sizes and designs. Donnings were performed with and without a pre-test leak checking method. For each method, four replicate FFR samples of each of the seven models were tested with two donnings per replicate, resulting in a total of 56 tests per donning method. Each fit factor evaluation was comprised of three 86-sec exercises: “Normal Breathing” (NB, 11.2 liters per min (lpm)), “Deep Breathing” (DB, 20.4 lpm), then NB again. A fit factor for each exercise and an overall test fit factor were obtained. Analysis of variance methods were used to identify statistical differences among fit factors (analyzed as logarithms) for different FFR models, exercises, and testing methods. For each FFR model and for each testing method, the NB and DB fit factor data were not significantly different (P > 0.05). Significant differences were seen in the overall exercise fit factor data for the two donning methods among all FFR models (pooled data) and in the overall exercise fit factor data for the two testing methods within certain models. Utilization of the leak checking method improved the rate of obtaining overall exercise fit factors ≥100. The FFR models, which are expected to achieve overall fit factors ≥ 100 on human subjects, achieved overall exercise fit factors ≥ 100 on the StAH. Further research is needed to evaluate the correlation of FFRs fitted on the StAH to FFRs fitted on people. PMID:24369934
Hariprasad, Seenu M; Singh, Ajay
2011-03-01
To test a novel hydrogel sealant to secure sutureless sclerotomies under variable intraocular pressure conditions. In cadaver eyes, 23- and 20-gauge (G) sclerotomies were constructed. Sixteen 23-G beveled sclerotomies were constructed in 4 eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were left bare. All sclerotomies were monitored for leaks while the intraocular pressure was elevated. The pressure on incision leakage was recorded as the leak pressure (maximum tested = 140 mm Hg). Additionally, sixteen 20-G sclerotomies were constructed in 4 other eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were sutured. These incisions were similarly pressure tested. Among the 23-G incisions, hydrogel sealant application to the incisions significantly increased the leak pressure relative to bare incisions: mean (SE), 131.8 (8.2) vs 39.5 (5.2) mm Hg, respectively (P < .001). Only 1 of the 8 sealant-treated 23-G incisions leaked below 140 mm Hg, compared with all of the 8 bare incisions. Among the 20-G incisions, there was no difference in leak pressure among sealant-treated and sutured incisions: mean (SE), 140.0 (0.0) vs 136.3 (3.8) mm Hg, respectively (P = .35). None of the 8 sealant-treated 20-G incisions leaked below 140 mm Hg, compared with 1 of the 8 sutured incisions. Hydrogel sealant significantly increased the leak pressure among 23-G incisions relative to 23-G bare incisions and was equivalent to suturing among 20-G incisions. Hydrogel sealants effectively close vitrectomy incisions and may decrease the incidence of postoperative endophthalmitis and hypotony.
Apparatus and method for detecting leaks in piping
Trapp, Donald J.
1994-01-01
A method and device for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe.
Steeper, Timothy J.
1989-01-01
A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port.
Noble Gas Leak Detector for Use in the SNS Neutron Electric Dipole Moment Experiment
NASA Astrophysics Data System (ADS)
Barrow, Chad; Huffman, Paul; Leung, Kent; Korobkina, Ekaterina; White, Christian; nEDM Collaboration Collaboration
2017-09-01
Common practice for leak-checking high vacuum systems uses helium as the probing gas. However, helium may permeate some materials at room temperature, making leak characterization difficult. The experiment to find a permanent electric dipole moment of the neutron (nEDM), to be conducted at Oak Ridge National Laboratories, will employ a large volume of liquid helium housed by such a helium-permeable composite material. It is desirable to construct a leak detector that can employ alternative test gases. The purpose of this experiment is to create a leak detector that can quantify the argon gas flux in a high vacuum environment and interpret this flux as a leak-rate. This apparatus will be used to check the nEDM volumes for leaks at room temperature before cooling down to cryogenic temperatures. Our leak detector uses a residual gas analyzer and a vacuum pumping station to characterize the gas present in an evacuated volume. The introduction of argon gas into the system is interpreted as a leak-rate into the volume. The device has been calibrated with NIST certified calibrated leaks and the machine's sensitivity has been calculated using background gas analysis. As a result of the device construction and software programming, we are able to leak-check composite and polyamide volumes This work was supported in part by the US Department of Energy under Grant No. DE-FG02-97ER41042.
NASA Astrophysics Data System (ADS)
Pathan, F. S.; Khan, Z.; Semwal, P.; Raval, D. C.; Joshi, K. S.; Thankey, P. L.; Dhanani, K. R.
2008-05-01
Steady State Super-conducting (SST-1) Tokamak is in commissioning stage at Institute for Plasma Research. Vacuum chamber of SST-1 Tokamak consists of 1) Vacuum vessel, an ultra high vacuum (UHV) chamber, 2) Cryostat, a high vacuum (HV) chamber. Cryostat encloses the liquid helium cooled super-conducting magnets (TF and PF), which require the thermal radiation protection against room temperature. Liquid nitrogen (LN2) cooled panels are used to provide thermal shield around super-conducting magnets. During operation, LN2 panels will be under pressurized condition and its surrounding (cryostat) will be at high vacuum. Hence, LN2 panels must have very low leak rate. This paper describes an experiment to study the behaviour of the leaks in LN2 panels during sniffer test and pressure drop test using helium gas.
Elastomeric Seal Performance after Terrestrial Ultraviolet Radiation Exposure
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.; Dunlap, Patrick H.
2015-01-01
Ultraviolet radiation was evaluated to determine its negative effects on the performance of elastomeric gas pressure seals. The leak rates of the silicone elastomer S0383-70 O-ring test articles were used to quantify the degradation of the seals after exposure to vacuum-ultraviolet and/or middle-to-near-ultraviolet wavelength radiation. Three groups of seals were exposed in terrestrial facilities to 115-165 nm wavelength radiation, 230-500 nm wavelength radiation, or both spectrums, for an orbital spaceflight equivalent of 125 hours. The leak rates of the silicone elastomer S0383-70 seals were quantified and compared to samples that received no radiation. Each lot contained six samples and statistical t-tests were used to determine the separate and combined influences of exposure to the two wavelength ranges. A comparison of the mean leak rates of samples exposed to 115-165 nm wavelength radiation to the control specimens showed no difference, suggesting that spectrum was not damaging. The 230-500 nm wavelength appeared to be damaging, as the mean leak rates of the specimens exposed to that range of wavelengths, and those exposed to the combined 115-165 nm and 230-500 nm spectrums, were significantly different from the leak rates of the control specimens. Most importantly, the test articles exposed to both wavelength spectrums exhibited mean leak rates two orders of magnitude larger than any other exposed specimens, which suggested that both wavelength spectrums are important when simulating the orbital environment.
Sikkema, Kathleen J.; Watt, Melissa H.; Masenga, Gileard G.; Mosha, Mary V.
2016-01-01
Objectives Obstetric fistula is a maternal injury that causes uncontrollable leaking of urine or stool, and most women who develop it live in poverty in low-income countries. Obstetric fistula is associated with high rates of stigma and psychological morbidity, but there is uncertainty about the impact of surgical treatment on psychological outcomes. The objective of this exploratory study was to examine changes in psychological symptoms following surgical fistula repair, discharge and reintegration home. Methods Women admitted for surgical repair of obstetric fistula were recruited from a Tanzanian hospital serving a rural catchment area. Psychological symptoms and social functioning were assessed prior to surgery. Approximately 3 months after discharge, a data collector visited the patients' homes to repeat psychosocial measures and assess self-reported incontinence. Baseline to follow-up differences were measured with paired t tests controlling for multiple comparisons. Associations between psychological outcomes and leaking were assessed with t tests and Pearson correlations. Results Participants (N = 28) had been living with fistula for an average of 11 years. Baseline psychological distress was high, and decreased significantly at follow-up. Participants who self-reported continued incontinence at follow-up endorsed significantly higher PTSD and depression symptoms than those who reported being cured, and severity of leaking was associated with psychological distress. Conclusions Fistula patients experience improvements in mental health at 3 months after discharge, but these improvements are curtailed when women experience residual leaking. Given the rate of stress incontinence following surgery, it is important to prepare fistula patients for the possibility of incomplete cure and help them develop appropriate coping strategies. PMID:27010550
Two-stream Convolutional Neural Network for Methane Emissions Quantification
NASA Astrophysics Data System (ADS)
Wang, J.; Ravikumar, A. P.; McGuire, M.; Bell, C.; Tchapmi, L. P.; Brandt, A. R.
2017-12-01
Methane, a key component of natural gas, has a 25x higher global warming potential than carbon dioxide on a 100-year basis. Accurately monitoring and mitigating methane emissions require cost-effective detection and quantification technologies. Optical gas imaging, one of the most commonly used leak detection technology, adopted by Environmental Protection Agency, cannot estimate leak-sizes. In this work, we harness advances in computer science to allow for rapid and automatic leak quantification. Particularly, we utilize two-stream deep Convolutional Networks (ConvNets) to estimate leak-size by capturing complementary spatial information from still plume frames, and temporal information from plume motion between frames. We build large leak datasets for training and evaluating purposes by collecting about 20 videos (i.e. 397,400 frames) of leaks. The videos were recorded at six distances from the source, covering 10 -60 ft. Leak sources included natural gas well-heads, separators, and tanks. All frames were labeled with a true leak size, which has eight levels ranging from 0 to 140 MCFH. Preliminary analysis shows that two-stream ConvNets provides significant accuracy advantage over single steam ConvNets. Spatial stream ConvNet can achieve an accuracy of 65.2%, by extracting important features, including texture, plume area, and pattern. Temporal stream, fed by the results of optical flow analysis, results in an accuracy of 58.3%. The integration of the two-stream ConvNets gives a combined accuracy of 77.6%. For future work, we will split the training and testing datasets in distinct ways in order to test the generalization of the algorithm for different leak sources. Several analytic metrics, including confusion matrix and visualization of key features, will be used to understand accuracy rates and occurrences of false positives. The quantification algorithm can help to find and fix super-emitters, and improve the cost-effectiveness of leak detection and repair programs.
40 CFR 61.242-7 - Standards: Valves.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Equipment Leaks... detect leaks by the method specified in § 61.245(b) and shall comply with paragraphs (b)-(e), except as...) If an instrument reading of 10,000 ppm or greater is measured, a leak is detected. (c)(1) Any valve...
Leak and Pipe Detection Method and System
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor)
2003-01-01
A method and system for locating leaks of conductive fluids from non-conductive pipes and other structures or for locat- ing non-conductive pipes or structures having conductive fluid contained therein, employ a charge generator to apply a time varying charge to the conductive fluid, and a capaci- tive type detector that can detect the variable charge that is induced in the fluid. The capacitive detector, which prefer- ably includes a handheld housing, employs a large conduc- tive pickup plate that is used to locate the pipe or leak by scanning the plate over the ground and detecting the induced charge that is generated when the plate comes in close proximity to the pipe or leak. If a leak is encountered, the resulting signal will appear over an area larger than expected for a buried pipe, assuming the leak provides an electrically conductive path between the flow and the wet surrounding ground. The detector uses any suitable type of indicator device, such as a pair of headphones that enable an operator to hear the detected signal as a chirping sound, for example.
EIGHTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
2013-09-03
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23more » GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 61 - 85 months, which is still bounding to O-ring temperatures during storage in KArea Complex (KAC). Based on expectations that the fixtures aging at 200 ºF will remain leaktight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 41 - 45 months. Aging and periodic leak testing will continue for the remaining PCV fixtures.« less
Racine, Stéphane X; Solis, Audrey; Hamou, Nora Ait; Letoumelin, Philippe; Hepner, David L; Beloucif, Sadek; Baillard, Christophe
2010-05-01
In edentulous patients, it may be difficult to perform face mask ventilation because of inadequate seal with air leaks. Our aim was to ascertain whether the "lower lip" face mask placement, as a new face mask ventilation method, is more effective at reducing air leaks than the standard face mask placement. Forty-nine edentulous patients with inadequate seal and air leak during two-hand positive-pressure ventilation using the ventilator circle system were prospectively evaluated. In the presence of air leaks, defined as a difference of at least 33% between inspired and expired tidal volumes, the mask was placed in a lower lip position by repositioning the caudal end of the mask above the lower lip while maintaining the head in extension. The results are expressed as mean +/- SD or median (25th-75th percentiles). Patient characteristics included age (71 +/- 11 yr) and body mass index (24 +/- 4 kg/m2). By using the standard method, the median inspired and expired tidal volumes were 450 ml (400-500 ml) and 0 ml (0-50 ml), respectively, and the median air leak was 400 ml (365-485 ml). After placing the mask in the lower lip position, the median expired tidal volume increased to 400 ml (380-490), and the median air leak decreased to 10 ml (0-20 ml) (P < 0.001 vs. standard method). The lower lip face mask placement with two hands reduced the air leak by 95% (80-100%). In edentulous patients with inadequate face mask ventilation, the lower lip face mask placement with two hands markedly reduced the air leak and improved ventilation.
NASA Astrophysics Data System (ADS)
Gao, Yan; Liu, Yuyou; Ma, Yifan; Cheng, Xiaobin; Yang, Jun
2018-11-01
One major challenge currently facing pipeline networks across the world is the improvement of leak detection technologies in urban environments. There is an imperative to locate accurately leaks in buried water pipes to avoid serious environmental, social and economic consequences. Much attention has been paid to time delay estimation (TDE) in determining the position of a leak by utilising cross-correlation, which has been proven to be effective with varying degrees of success over the past half century. Previous research in published literature has demonstrated the effectiveness of the pre-whitening process for accentuating the peak in the cross-correlation associated with the time delay. This paper is concerned with the implementation of the differentiation process for TDE, with particular focus on the problem of determining a leak in pipelines by means of pipe pressure measurements. Rather than the pre-whitening operation, the proposed cross-correlation via the differentiation process, termed here DIF, changes the characteristics of the pipe system so that the pipe effectively acts as a band-pass filter. This method has the potential to eliminate some ambiguity caused by the interference at low frequencies and to allow more high frequency information to pass. Given an appropriate differentiation order, a more pronounced and reliable peak is obtained in the cross-correlation result. The use of differentiation process may provide a viable cross-correlation method suited to water leak detection. Its performance in relation to leak detection is further compared to the basic cross-correlation and pre-whitening methods for TDE in detecting a leak from actual PVC water pipes. Experimental results are presented to show an additional property of the DIF compensating for the resonance effects that may exist in cross-spectral density measurements, and hence better performance for TDE.
Optimal sensor placement for leak location in water distribution networks using genetic algorithms.
Casillas, Myrna V; Puig, Vicenç; Garza-Castañón, Luis E; Rosich, Albert
2013-11-04
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach.
Optimal Sensor Placement for Leak Location in Water Distribution Networks Using Genetic Algorithms
Casillas, Myrna V.; Puig, Vicenç; Garza-Castañón, Luis E.; Rosich, Albert
2013-01-01
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach. PMID:24193099
Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning
2012-01-01
In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point’s position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate. PMID:22368464
Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning
2012-01-01
In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point's position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.
Method and apparatus for detecting irregularities on or in the wall of a vessel
Bowling, Michael Keith
2000-09-12
A method of detecting irregularities on or in the wall of a vessel by detecting localized spatial temperature differentials on the wall surface, comprising scanning the vessel surface with a thermal imaging camera and recording the position of the or each region for which the thermal image from the camera is indicative of such a temperature differential across the region. The spatial temperature differential may be formed by bacterial growth on the vessel surface; alternatively, it may be the result of defects in the vessel wall such as thin regions or pin holes or cracks. The detection of leaks through the vessel wall may be enhanced by applying a pressure differential or a temperature differential across the vessel wall; the testing for leaks may be performed with the vessel full or empty, and from the inside or the outside.
Operational Philosophy Concerning Manned Spacecraft Cabin Leaks
NASA Technical Reports Server (NTRS)
DeSimpelaere, Edward
2011-01-01
The last thirty years have seen the Space Shuttle as the prime United States spacecraft for manned spaceflight missions. Many lessons have been learned about spacecraft design and operation throughout these years. Over the next few decades, a large increase of manned spaceflight in the commercial sector is expected. This will result in the exposure of commercial crews and passengers to many of the same risks crews of the Space Shuttle have encountered. One of the more dire situations that can be encountered is the loss of pressure in the habitable volume of the spacecraft during on orbit operations. This is referred to as a cabin leak. This paper seeks to establish a general cabin leak response philosophy with the intent of educating future spacecraft designers and operators. After establishing a relative definition for a cabin leak, the paper covers general descriptions of detection equipment, detection methods, and general operational methods for management of a cabin leak. Subsequently, all these items are addressed from the perspective of the Space Shuttle Program, as this will be of the most value to future spacecraft due to similar operating profiles. Emphasis here is placed upon why and how these methods and philosophies have evolved to meet the Space Shuttle s needs. This includes the core ideas of: considerations of maintaining higher cabin pressures vs. lower cabin pressures, the pros and cons of a system designed to feed the leak with gas from pressurized tanks vs. using pressure suits to protect against lower cabin pressures, timeline and consumables constraints, re-entry considerations with leaks of unknown origin, and the impact the International Space Station (ISS) has had to the standard Space Shuttle cabin leak response philosophy. This last item in itself includes: procedural management differences, hardware considerations, additional capabilities due to the presence of the ISS and its resource, and ISS docking/undocking considerations with a cabin leak occurring. The paper also offers a look at how different equipment configurations on future spacecraft impact the previously defined cabin leak operational philosophy and includes additional operational methods and considerations that result due to various configurations. The intent is to showcase these various considerations and highlight the variability they allow. The paper concludes with a selection of the author s personal observations from a spacecraft operator's point of view and recommendations with the goal of improving the design and operations of future spacecraft.
NASA Technical Reports Server (NTRS)
Rodriguez, P. I.; Markovitch, R.
1992-01-01
This report is intended to reveal the apparent relationship of air seal leakage rates between 2 atmospheres (atm) to 1 atm and 1 atm to vacuum conditions. Gas dynamics analysis is provided as well as data summarizing the MSFC test report, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study With Delta Pressure Leak Rate Comparison Test Report'.
Aberrant Wound-Healing Response in Mitomycin C-Treated Leaking Blebs: A Histopathologic Study
Elner, Victor M.; Newman-Casey, Paula Anne; Patil, A. Jayaprakash; Flint, Andrew; Biswas, Jyotirmay; Moroi, Sayoko E.; Pushparaj, Vaijayanthi; Edward, Deepak P.
2014-01-01
Objective To characterize histopathologic features of leaking mitomycin-C-treated blebs and aberrant wound healing that may lead to persistent conjunctival thinning and leakage. Methods Forty mitomycin C-treated filtering blebs excised for persistent leaks from 40 patients were examined histopathologically using hematoxylin-eosin, periodic acid-Schiff, Masson trichrome, and Alcian blue histochemical stains. Results Ninety percent of the leaking blebs contained epithelial-stromal domes with areas of acellular stroma covered by attenuated epithelium. Seventy-five percent of the blebs demonstrated varying degrees of fibrovascular repair growing from the bleb margin, either beneath or interdigitating with the acellular zone. A novel observation in 65% of specimens was Alcian blue-positive myxoid stroma at the interface between the fibrovascular proliferation and the epithelial-stromal dome. The association between the presence of fibrovascular proliferation and Alcian-blue staining myxoid stroma was significant by Fisher exact test (P=0.002). Conclusions A desirable filtration bleb requires a sufficient reparative fibrovascular response to maintain an epithelial-stromal barrier in order to prevent leakage. Fibroblasts must lay down a continuous collagen-rich fibrous layer, rather than merely myxoid stroma, beneath the conjunctival epithelium to promote bleb stability. Surgical techniques and postsurgical care should aim to attain this desired outcome. PMID:19667341
NASA Astrophysics Data System (ADS)
Shaanika, E.; Yamaguchi, K.; Miki, M.; Ida, T.; Izumi, M.; Murase, Y.; Oryu, T.; Yanamoto, T.
2017-12-01
Superconducting generators offer numerous advantages over conventional generators of the same rating. They are lighter, smaller and more efficient. Amongst a host of methods for cooling HTS machinery, thermosyphon-based cooling systems have been employed due to their high heat transfer rate and near-isothermal operating characteristics associated with them. To use them optimally, it is essential to study thermal characteristics of these cryogenic thermosyphons. To this end, a stand-alone neon thermosyphon cooling system with a topology resembling an HTS rotating machine was studied. Heat load tests were conducted on the neon thermosyphon cooling system by applying a series of heat loads to the evaporator at different filling ratios. The temperature at selected points of evaporator, adiabatic tube and condenser as well as total heat leak were measured. A further study involving a computer thermal model was conducted to gain further insight into the estimated temperature distribution of thermosyphon components and heat leak of the cooling system. The model employed boundary conditions from data of heat load tests. This work presents a comparison between estimated (by model) and experimental (measured) temperature distribution in a two-phase cryogenic thermosyphon cooling system. The simulation results of temperature distribution and heat leak compared generally well with experimental data.
An improved PCA method with application to boiler leak detection.
Sun, Xi; Marquez, Horacio J; Chen, Tongwen; Riaz, Muhammad
2005-07-01
Principal component analysis (PCA) is a popular fault detection technique. It has been widely used in process industries, especially in the chemical industry. In industrial applications, achieving a sensitive system capable of detecting incipient faults, which maintains the false alarm rate to a minimum, is a crucial issue. Although a lot of research has been focused on these issues for PCA-based fault detection and diagnosis methods, sensitivity of the fault detection scheme versus false alarm rate continues to be an important issue. In this paper, an improved PCA method is proposed to address this problem. In this method, a new data preprocessing scheme and a new fault detection scheme designed for Hotelling's T2 as well as the squared prediction error are developed. A dynamic PCA model is also developed for boiler leak detection. This new method is applied to boiler water/steam leak detection with real data from Syncrude Canada's utility plant in Fort McMurray, Canada. Our results demonstrate that the proposed method can effectively reduce false alarm rate, provide effective and correct leak alarms, and give early warning to operators.
Detection of Leaks in Water Distribution System using Non-Destructive Techniques
NASA Astrophysics Data System (ADS)
Aslam, H.; Kaur, M.; Sasi, S.; Mortula, Md M.; Yehia, S.; Ali, T.
2018-05-01
Water is scarce and needs to be conserved. A considerable amount of water which flows in the water distribution systems was found to be lost due to pipe leaks. Consequently, innovations in methods of pipe leakage detections for early recognition and repair of these leaks is vital to ensure minimum wastage of water in distribution systems. A major component of detection of pipe leaks is the ability to accurately locate the leak location in pipes through minimum invasion. Therefore, this paper studies the leak detection abilities of the three NDT’s: Ground Penetration Radar (GPR) and spectrometer and aims at determining whether these instruments are effective in identifying the leak. An experimental setup was constructed to simulate the underground conditions of water distribution systems. After analysing the experimental data, it was concluded that both the GPR and the spectrometer were effective in detecting leaks in the pipes. However, the results obtained from the spectrometer were not very differentiating in terms of observing the leaks in comparison to the results obtained from the GPR. In addition to this, it was concluded that both instruments could not be used if the water from the leaks had reached on the surface, resulting in surface ponding.
Steeper, T.J.
1989-12-26
A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port. 2 figs.
Brand, Y; Lim, E; Waran, V; Prepageran, N
2015-12-01
Endoscopic endonasal techniques have recently become the method of choice in dealing with cerebrospinal fluid leak involving the anterior cranial fossa. However, most surgeons prefer an intracranial approach when leaks involve the middle cranial fossa. This case report illustrates the possibilities of using endoscopic techniques for cerebrospinal fluid leaks involving the middle fossa. A 37-year-old male patient presented with multiple areas of cranial defect with cerebrospinal fluid leak due to osteoradionecrosis following radiation for nasopharyngeal carcinoma 4 years earlier. Clinical examination showed involvement of all cranial nerves except the IInd and XIth nerves on the left side. A prior attempt to repair the cerebrospinal fluid leak with craniotomy was not successful. This case demonstrates the successful endoscopic repair of a large cranial defect with cerebrospinal fluid leak.
Itagaki, Taiga; Bennett, Desmond J; Chenelle, Christopher T; Fisher, Daniel F; Kacmarek, Robert M
2017-01-01
Volume-targeted ventilation is increasingly used in low birthweight infants because of the potential for reducing volutrauma and avoiding hypocapnea. However, it is not known what level of air leak is acceptable during neonatal volume-targeted ventilation when leak compensation is activated concurrently. Four ICU ventilators (Servo-i, PB980, V500, and Avea) were compared in available invasive volume-targeted ventilation modes (pressure control continuous spontaneous ventilation [PC-CSV] and pressure control continuous mandatory ventilation [PC-CMV]). The Servo-i and PB980 were tested with (+) and without (-) their proximal flow sensor. The V500 and Avea were tested with their proximal flow sensor as indicated by their manufacturers. An ASL 5000 lung model was used to simulate 4 neonatal scenarios (body weight 0.5, 1, 2, and 4 kg). The ASL 5000 was ventilated via an endotracheal tube with 3 different leaks. Two minutes of data were collected after each change in leak level, and the asynchrony index was calculated. Tidal volume (V T ) before and after the change in leak was assessed. The differences in delivered V T between before and after the change in leak were within ±5% in all scenarios with the PB980 (-/+) and V500. With the Servo-i (-/+), baseline V T was ≥10% greater than set V T during PC-CSV, and delivered V T markedly changed with leak. The Avea demonstrated persistent high V T in all leak scenarios. Across all ventilators, the median asynchrony index was 1% (interquartile range 0-27%) in PC-CSV and 1.8% (0-45%) in PC-CMV. The median asynchrony index was significantly higher in the Servo-i (-/+) than in the PB980 (-/+) and V500 in 1 and 2 kg scenarios during PC-CSV and PC-CMV. The PB980 and V500 were the only ventilators to acclimate to all leak scenarios and achieve targeted V T . Further clinical investigation is needed to validate the use of leak compensation during neonatal volume-targeted ventilation. Copyright © 2017 by Daedalus Enterprises.
Ultra high vacuum pumping system and high sensitivity helium leak detector
Myneni, Ganapati Rao
1997-01-01
An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.
Apparatus and method for detecting leaks in piping
Trapp, D.J.
1994-12-27
A method and device are disclosed for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe. 2 figures.
Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2.
Wood, Fiona E; Morley, Colin J; Dawson, Jennifer A; Kamlin, C Omar F; Owen, Louise S; Donath, Susan; Davis, Peter G
2008-05-01
Techniques of positioning and holding neonatal face masks vary. Studies have shown that leak at the face mask is common and often substantial irrespective of operator experience. (1) To identify a technique for face mask placement and hold which will minimise mask leak. (2) To investigate the effect of written instruction and demonstration of the identified technique on mask leak for two round face masks. Three experienced neonatologists compared methods of placing and holding face masks to minimise the leak for Fisher & Paykel 60 mm and Laerdal size 0/1 masks. 50 clinical staff gave positive pressure ventilation to a modified manikin designed to measure leak at the face mask. They were provided with written instructions on how to position and hold each mask and then received a demonstration. Face mask leak was measured after each teaching intervention. A technique of positioning and holding the face masks was identified which minimised leak. The mean (SD) mask leaks before instruction, after instruction and after demonstration were 55% (31), 49% (30), 33% (26) for the Laerdal mask and 57% (25), 47% (28), 32% (30) for the Fisher & Paykel mask. There was no significant difference in mask leak between the two masks. Written instruction alone reduced leak by 8.8% (CI 1.4% to 16.2%) for either mask; when combined with a demonstration mask leak was reduced by 24.1% (CI 16.4% to 31.8%). Written instruction and demonstration of the identified optimal technique resulted in significantly reduced face mask leak.
Terterov, Dimitry; Leung, Philemon Ho-Yan; Twells, Laurie K; Gregory, Deborah M; Smith, Chris; Boone, Darrell; Pace, David
2017-09-01
Although laparoscopic sleeve gastrectomy (LSG) has been shown to be a safe and effective treatment for severe obesity (body mass index ≥ 35), staple line leaks remain a major complication and account for a substantial portion of the procedure's morbidity and mortality. Many centres performing LSG routinely obtain contrast studies on postoperative day 1 for early detection of staple line leaks. We examined the usefulness of Gastrografin swallow as an early detection test for staple line leaks on postoperative day 1 after LSG as well as the associated costs. We conducted a retrospective review of a prospectively collected database that included 200 patients who underwent LSG for severe obesity between 2011 and 2014. Primary outcome measures were the incidence of staple line leaks and the results of Gastrografin swallow tests. We obtained imaging costs from appropriate hospital departments. Gastrografin swallow was obtained on postoperative day 1 for all 200 patients who underwent LSG. Three patients (1.5%) were found to have staple line leaks. Gastrograffin swallows yielded 1 true positive result and 2 false negatives. The false negatives were subsequently diagnosed on computed tomography (CT) scan. The sensitivity of Gastrografin swallow in this study was 33%. For 200 patients, the total direct cost of the Gastrografin swallows was $35 000. The use of routine upper gastrointestinal contrast studies for early detection of staple line leaks has low sensitivity and is costly. We recommend selective use of CT instead.
The minimal leak test technique for endotracheal cuff maintenance.
Harvie, D A; Darvall, J N; Dodd, M; De La Cruz, A; Tacey, M; D'Costa, R L; Ward, D
2016-09-01
Endotracheal tube (ETT) cuff pressure management is an essential part of airway management in intubated and mechanically ventilated patients. Both under- and over-inflation of the ETT cuff can lead to patient complications, with an ideal pressure range of 20-30 cmH 2 O defined. A range of techniques are employed to ensure adequate ETT cuff inflation, with little comparative data. We performed an observational cross-sectional study in a tertiary metropolitan ICU, assessing the relationship between the minimal leak test and cuff manometry. Forty-five mechanically ventilated patients, over a three-month period, had ETT cuff manometry performed at the same time as their routine cuff maintenance (minimal leak test). Bedside nurse measurements were compared with investigator measurements. At the endpoint of cuff inflation, 20 of 45 patients (44%) had cuff pressures between 20 and 30 cmH 2 O; 11 of 45 patients (24%) had cuff pressures <20 cmH 2 O; 14 of 45 patients (31%) had cuff pressures ≥30 cmH 2 O. Univariate analysis demonstrated an association between both patient obesity and female gender requiring less ETT cuff volume ( P =0.008 and P <0.001 respectively), though this association was lost on multivariate analysis. No association was demonstrated between any measured variables and cuff pressures. Inter-operator reliability in performing the minimal leak test showed no evidence of bias between nurse and investigators (Pearson coefficient = 0.897). We conclude the minimal leak test for maintenance of ETT cuffs leads to both over- and under-inflation, and alternative techniques, such as cuff manometry, should be employed.
Blind Leak Detection for Closed Systems
NASA Technical Reports Server (NTRS)
Oelgoetz, Peter; Johnson, Ricky; Todd, Douglas; Russell, Samuel; Walker, James
2003-01-01
The current inspection technique for locating interstitial leaking in the Space Shuttle Main Engine nozzles is the application of a liquid leak check solution in the openings where the interstitials space between the tubing and the structural jacket vent out the aft end of the nozzle, while its cooling tubes are pressurized to 25 psig with Helium. When a leak is found, it is classified, and if the leak is severe enough the suspect tube is cut open so that a boroscope can be inserted to find the leak point. Since the boroscope can only cover a finite tube length and since it is impossible to identify which tube (to the right or left of the identified interstitial) is leaking, many extra and undesired repairs have been made to fix just one leak. In certain instances when the interstitials are interlinked by poor braze bonding, many interstitials will show indications of leaking from a single source. What is desired is a technique that can identify the leak source so that a single repair can be performed. Dr, Samuel Russell and James Walker, both with NASA/MSFC have developed a thermographic inspection system that addresses a single repair approach. They have teamed with Boeing/Rocketdyne to repackage the inspection processes to be suitable to address full scale Shuttle development and flight hardware and implement the process at NASA centers. The methods and results presented address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera (capable of detecting a delta temperature difference of 0.025 C) is used to record the cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner hot wall surface as the nozzle is pressurized, These images are enhanced by digitally subtracting a thermal reference image taken before pressurization. The method provides a non-intrusive way of locating the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation. Other applications for this thermographic inspection system are the Reinforced-Carbon-Carbon (RCC) leading edge of the Space Shuttle orbiter and braze joint integrity.
Seven Ventilators Challenged With Leaks During Neonatal Nasal CPAP: An Experimental Pilot Study.
Drevhammar, Thomas; Nilsson, Kjell; Zetterström, Henrik; Jonsson, Baldvin
2015-07-01
Nasal CPAP is the most common respiratory support for neonates. Several factors are considered important for effective treatment, including leaks at the patient interface and the delivery of pressure-stable CPAP. Investigations of pressure stability during leaks should include both the change in the mean delivered CPAP and the pressure variation during each breath. The aim of this study was to examine the response of ventilators delivering nasal CPAP when challenged with leaks at the patient interface. Seven ventilators providing nasal CPAP at 4 cm H2O were challenged with leaks during simulated neonatal breathing. Leak was applied for 15 consecutive breaths at a constant level (1-4 L/min). The 2 aspects of pressure stability were evaluated by measuring the mean delivered CPAP and the amplitude of pressure swings before, during, and after leaks. The ability to maintain the delivered CPAP and the amplitude of pressure swings varied greatly among the 7 ventilators before, during, and after leaks. Four of the ventilators tested have built-in leak compensation. There was no simple relationship between maintaining delivered CPAP during leaks and providing CPAP with low pressure swing amplitude. Maintaining the delivered CPAP and providing this without pressure swings are 2 separate aspects of pressure stability, and investigations concerning the clinical importance of pressure stability should address both aspects. This study also shows that compensation for leaks does not necessarily provide pressure-stable CPAP. Copyright © 2015 by Daedalus Enterprises.
40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2012 CFR
2012-07-01
... leak detection system must be installed in each baghouse compartment or cell. For negative pressure or... scrubber, in place of hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner... for monitoring hydrogen chloride emissions discharged to the atmosphere and record the output of the...
Stapleton, Amanda L; Tyler-Kabara, Elizabeth C; Gardner, Paul A; Snyderman, Carl H; Wang, Eric W
2017-02-01
To determine the risk factors associated with cerebrospinal fluid (CSF) leak following endoscopic endonasal surgery (EES) for pediatric skull base lesions. Retrospective chart review of pediatric patients (ages 1 month to 18 years) treated for skull base lesions with EES from 1999 to 2014. Five pathologies were reviewed: craniopharyngioma, clival chordoma, pituitary adenoma, pituitary carcinoma, and Rathke's cleft cyst. Fisher's exact tests were used to evaluate the different factors to determine which had a statistically higher risk of leading to a post-operative CSF leak. 55 pediatric patients were identified who underwent 70 EES's for tumor resection. Of the 70 surgeries, 47 surgeries had intraoperative CSF leaks that were repaired at the time of surgery. 11 of 47 (23%) surgeries had post-operative CSF leaks that required secondary operative repair. Clival chordomas had the highest CSF leak rate at 36%. There was no statistical difference in leak rate based on the type of reconstruction, although 28% of cases that used a vascularized flap had a post-operative leak, whereas only 9% of those cases not using a vascularized flap had a leak. Post-operative hydrocephalus and perioperative use of a lumbar drain were not significant risk factors. Pediatric patients with an intra-operative CSF leak during EES of the skull base have a high rate of post-operative CSF leaks. Clival chordomas appear to be a particularly high-risk group. The use of vascularized flaps and perioperative lumbar drains did not statistically decrease the rate of post-operative CSF leak. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 86.319-79 - Analyzer checks and calibrations; frequency and overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... during testing, perform the following: (1) Leak check the pressure side of the system (see § 86.328). If the option described in § 86.328(b)(2) is used, a pressure leak check is not required. (2) Calibrate... need be checked only every 90 days. (d) At least once every 90 days during testing check the water...
Nikolian, Vahagn C; Kamdar, Neil S; Regenbogen, Scott E; Morris, Arden M; Byrn, John C; Suwanabol, Pasithorn A; Campbell, Darrell A; Hendren, Samantha
2017-06-01
Anastomotic leak is a major source of morbidity in colorectal operations and has become an area of interest in performance metrics. It is unclear whether anastomotic leak is associated primarily with surgeons' technical performance or explained better by patient characteristics and institutional factors. We sought to establish if anastomotic leak could serve as a valid quality metric in colorectal operations by evaluating provider variation after adjusting for patient factors. We performed a retrospective cohort study of colorectal resection patients in the Michigan Surgical Quality Collaborative. Clinically relevant patient and operative factors were tested for association with anastomotic leak. Hierarchical logistic regression was used to derive risk-adjusted rates of anastomotic leak. Of 9,192 colorectal resections, 244 (2.7%) had a documented anastomotic leak. The incidence of anastomotic leak was 3.0% for patients with pelvic anastomoses and 2.5% for those with intra-abdominal anastomoses. Multivariable analysis showed that a greater operative duration, male sex, body mass index >30 kg/m 2 , tobacco use, chronic immunosuppressive medications, thrombocytosis (platelet count >400 × 10 9 /L), and urgent/emergency operations were independently associated with anastomotic leak (C-statistic = 0.75). After accounting for patient and procedural risk factors, 5 hospitals had a significantly greater incidence of postoperative anastomotic leak. This population-based study shows that risk factors for anastomotic leak include male sex, obesity, tobacco use, immunosuppression, thrombocytosis, greater operative duration, and urgent/emergency operation; models including these factors predict most of the variation in anastomotic leak rates. This study suggests that anastomotic leak can serve as a valid metric that can identify opportunities for quality improvement. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, R.N.
1991-05-01
The BNL-developed perfluorocarbon tracer (PFT) technology includes a rapid-response real-time (5-second) analyzer (COPS) which can detect PFT concentrations as low as 1 {times} 10{sup {minus}11} mL/mL and a concentrating analyzer (DTA) which can measure down to 1 {times} 10{sup {minus}12} mL of PFT--separately quantifying up to 4 PFTs in a 6-min cycle time or less. Based on this technology, experimental leak- rate design concepts are proposed for determining the effectiveness (hermeticity) of the seal of semiconductor devices with internal cavities from 0.01 to 1 mL. The concept is based on pressurizing with PFT-containing air for 60 seconds, purging with PFT-freemore » air for 60 seconds, pressure pulsing with air or He to extract the PFT leaked into the internal volume, and finally detecting the PFT vapor concentration with one of the two instruments. The COPS analyzer can quantify gross leaks from 1 {times} 10{sup {minus}7} to 1 {times} 10{sup {minus}3} mL/s in just 3 minutes for the complete test. The more-sensitive concentrating analyzer (DTA) can quantify fine leaks from 0.2 {times} 10{sup {minus}8} to 1 {times} 10{sup {minus}3} mL/s in just 12 minutes for the complete test; the latter procedure includes two determinations per test. 5 refs., 2 tabs.« less
Systems, methods, and apparatus of a low conductance silicon micro-leak for mass spectrometer inlet
NASA Technical Reports Server (NTRS)
Harpold, Dan N. (Inventor); Niemann, Hasso B. (Inventor); Jamieson, Brian G. (Inventor); Lynch, Bernard A. (Inventor)
2011-01-01
Systems, methods and apparatus are provided through which in some embodiments a mass spectrometer micro-leak includes a number of channels fabricated by semiconductor processing tools and that includes a number of inlet holes that provide access to the channels.
Systems, Methods, and Apparatus of a Low Conductance Silicon Micro-Leak for Mass Spectrometer Inlet
NASA Technical Reports Server (NTRS)
Harpold, Dan N. (Inventor); Niemann, Hasso B. (Inventor); Jamieson, Brian G. (Inventor); Lynch, Bernard A. (Inventor)
2013-01-01
Systems, methods and apparatus are provided through which in some embodiments a mass spectrometer micro-leak includes a number of channels fabricated by semiconductor processing tools and that includes a number of inlet holes that provide access to the channels.
Pickett, P.T.
A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.
Pickett, Patrick T.
1981-01-01
A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.
NASA Technical Reports Server (NTRS)
Russell, John M.
1994-01-01
In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.
NASA Astrophysics Data System (ADS)
Russell, John M.
1994-10-01
In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.
Treatment of cerebrospinal fluid leak after spine surgery.
Fang, Zhao; Tian, Rong; Jia, Yu-Tao; Xu, Tian-Tong; Liu, Yang
2017-04-01
Owing to the complexity of spinal surgery, there is a great prevalence of dural tear causing cerebrospinal fluid (CSF) leakage. Many studies focused on suture repair for dural tear to stop CSF leak. Now some new treatment strategies have shown a promising effect that is listed as follows: 1) creating watertight dural closure to stop CSF leak with the help of dural substitute material; and 2) retarding CSF leak by changing pressure difference, including reducing the subarachnoid fluid pressure, increasing the epidural space pressure and both. In fact several methods mentioned above are usually combined to treat CSF leak. However, no update review summarized the relevant studies implemented in recent years. In this review, the authors would compare the effects of different dural closure techniques, and introduce the latest treatment methods and mechanisms. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.
Evaluating All-Metal Valves for Use in a Tritium Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houk, L.; Payton, A.
In the tritium gas processing system, it is desired to minimize polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in the tritium process is valve components. A vendor has been identified that manufactures a valve that is marketed as being made from all-metal construction. This manufacturer, Ham-Let Group, manufactures a diaphragm valve (3LE series) that claims to be made entirely of metal. SRNL procured twelve (12) Ham-Let diaphragm valves for characterization and evaluation. The characterization tests include identification of the maximum pressure of these valves by performing pressure and burst tests. Leak testsmore » were performed to ensure the valves do not exceed the acceptable leak rate for tritium service. These valves were then cycled in a nitrogen gas and/or vacuum environment to ensure they would be durable in a process environment. They were subsequently leak tested per ASTM protocol to ensure that the valves maintained their leak tight integrity. A detailed material analysis was also conducted to determine hydrogen and tritium compatibility.« less
Hydrogen leak detection in the Space Shuttle
NASA Technical Reports Server (NTRS)
Barile, Ronald G
1992-01-01
This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter, jet velocity, sample tube design, radial effects, vertical flow, and low hydrogen concentrations (1 percent). A frequent observation was that the power spectrum, calculated from the Fourier transform of concentration fluctuations, gives a separate piece of information from concentration. Many of the tests suggest that power is high where mixing occurs at the helium-air interface. This fact is apparently independent of the concentration level, which could be high or low, but depends on the sample location relative to the jet (leak) origin, whereas high concentration may be due to a strong leak far away or a small leak close to the sample tube. If the power is low for any concentration level, this would signify helium is arriving at the sample tube by diffusion, not chaotic mixing caused by the jet interaction with air. The practical result is to propose a modification of the HGDL mass spectrometer data sampling and software so that sampling rates could be capable of observing at least 25 Hz fluctuations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... or monitoring Method TANKS: 63.1256(b)(3)(i) Inspect fixed roof and all openings for leaks Initially... openings for leaks Initially Semiannually Visual. 63.1256(c)(2) Inspect surface impoundment for control....1256(d)(1)(ii) Inspect cover and all openings for leaks Initially Semiannually Visual. 63.1256(d)(3)(i...
Ultra high vacuum pumping system and high sensitivity helium leak detector
Myneni, G.R.
1997-12-30
An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10{sup {minus}13} atm cc/s. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces back streaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium. 2 figs.
Method of locating a leaking fuel element in a fast breeder power reactor
Honekamp, John R.; Fryer, Richard M.
1978-01-01
Leaking fuel elements in a fast reactor are identified by measuring the ratio of .sup.134 Xe to .sup.133 Xe in the reactor cover gas following detection of a fuel element leak, this ratio being indicative of the power and burnup of the failed fuel element. This procedure can be used to identify leaking fuel elements in a power breeder reactor while continuing operation of the reactor since the ratio measured is that of the gases stored in the plenum of the failed fuel element. Thus, use of a cleanup system for the cover gas makes it possible to identify sequentially a multiplicity of leaking fuel elements without shutting the reactor down.
Thermographic Nondestructive Evaluation of the Space Shuttle Main Engine Nozzle
NASA Technical Reports Server (NTRS)
Walker, James L.; Lansing, Matthew D.; Russell, Samuel S.; Caraccioli, Paul; Whitaker, Ann F. (Technical Monitor)
2000-01-01
The methods and results presented in this summary address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.
Rapid spontaneous cerebrospinal fluid leak detected in the gastrointestinal tract.
Ma, Hong Yun; Sen, Papia; Stein, Evan G; Freeman, Leonard M
2014-02-01
There are many causes of cerebrospinal (CSF) leaks. Most cases are secondary to blunt trauma and iatrogenic trauma caused by postoperative sequelae. Occasionally, CSF leakage may occur from nontraumatic or "spontaneous" causes, such as benign intracranial hypertension and "empty sella syndrome." Mass effect due to an encephalocele or meningocele may also be seen. Radionuclide cisternography is a sensitive method of determining CSF leak when combined with intranasal cotton pledget placement and analysis. We present a spontaneous CSF fluid leak that was detected when scintigraphic activity appeared first in the gastrointestinal tract.
Dangerous gas detection based on infrared video
NASA Astrophysics Data System (ADS)
Ding, Kang; Hong, Hanyu; Huang, Likun
2018-03-01
As the gas leak infrared imaging detection technology has significant advantages of high efficiency and remote imaging detection, in order to enhance the detail perception of observers and equivalently improve the detection limit, we propose a new type of gas leak infrared image detection method, which combines background difference methods and multi-frame interval difference method. Compared to the traditional frame methods, the multi-frame interval difference method we proposed can extract a more complete target image. By fusing the background difference image and the multi-frame interval difference image, we can accumulate the information of infrared target image of the gas leak in many aspect. The experiment demonstrate that the completeness of the gas leakage trace information is enhanced significantly, and the real-time detection effect can be achieved.
Reinstein, Eyal; Pariani, Mitchel; Bannykh, Serguei; Rimoin, David L; Schievink, Wouter I
2013-04-01
We aimed to assess the frequency of connective tissue abnormalities among patients with cerebrospinal fluid (CSF) leaks in a prospective study using a large cohort of patients. We enrolled a consecutive group of 50 patients, referred for consultation because of CSF leak. All patients have been carefully examined for the presence of connective tissue abnormalities, and based on findings, patients underwent genetic testing. Ancillary diagnostic studies included echocardiography, eye exam, and histopathological examinations of skin and dura biopsies in selected patients. We identified nine patients with heritable connective tissue disorders, including Marfan syndrome, Ehlers-Danlos syndrome and other unclassified forms. In seven patients, spontaneous CSF leak was the first noted manifestation of the genetic disorder. We conclude that spontaneous CSF leaks are associated with a spectrum of connective tissue abnormalities and may be the first noted clinical presentation of the genetic disorder. We propose that there is a clinical basis for considering spontaneous CSF leak as a clinical manifestation of heritable connective tissue disorders, and we suggest that patients with CSF leaks should be screened for connective tissue and vascular abnormalities.
NASA Technical Reports Server (NTRS)
Byrne, E. J.
1979-01-01
Quantitative leak detector visually demonstrates refrigerant loss from precision volume of large refrigeration system over established period of time from single test point. Mechanical unit is less costly than electronic "sniffers" and is more reliable due to absence of electronic circuits that are susceptible to drift.
NASA Astrophysics Data System (ADS)
Al-Shukri, H.; Eyuboglu, S.; Mahdi, H.
2005-12-01
Many geophysical techniques have been suggested as candidates for detecting water leakage in water distribution system, including ground penetrating radar (GPR), acoustic devices, and gas sampling devices. A series of laboratory experiments were conducted to determine the validity and effectiveness of GPR in detecting water leakage in metal and plastic PVC pipes. The goal was to derive a practical and robust procedure for detecting such leakage. Initially, prototype laboratory experiments were designed to simulate leaks in both PVC and metal pipe. The experiments were very well controlled and results obtained indicate that GPR is effective in detecting subsurface water leaks. This was followed by an outdoor life size experiments. 50 feet by 30 feet by 5 feet test bed was constructed using local soil and commercial water distribution pipes. A 400 MHz antenna was used to collect three-dimensional GPR data as a function of time for a number of experiments using different type of pipes. Advanced imaging and visualization technology was used to further analyze the data. The UALR Virtual Reality Center CAVE facilities were utilized to accomplish this test. Results obtained indicate that GPR is effective in detecting subsurface water leaks in both pipes. Synthetic models of the GPR signals based on Finite Difference Time Domain Method (FDTD) were built to help select an appropriate equipment configuration (frequency band, type of antenna, and real-time imaging software) prior to data acquisition. The simulation software was used to determine the near-field radiation characteristics of the GPR antenna. Different experimental models were adapted for which observational GPR data was previously collected. Matlab regression analysis was used to generate the incident waves for each model to ensure highly accurate and controlled experiments.
Wilson, Sarah M; Sikkema, Kathleen J; Watt, Melissa H; Masenga, Gileard G; Mosha, Mary V
2016-05-01
Objectives Obstetric fistula is a maternal injury that causes uncontrollable leaking of urine or stool, and most women who develop it live in poverty in low-income countries. Obstetric fistula is associated with high rates of stigma and psychological morbidity, but there is uncertainty about the impact of surgical treatment on psychological outcomes. The objective of this exploratory study was to examine changes in psychological symptoms following surgical fistula repair, discharge and reintegration home. Methods Women admitted for surgical repair of obstetric fistula were recruited from a Tanzanian hospital serving a rural catchment area. Psychological symptoms and social functioning were assessed prior to surgery. Approximately 3 months after discharge, a data collector visited the patients' homes to repeat psychosocial measures and assess self-reported incontinence. Baseline to follow-up differences were measured with paired t tests controlling for multiple comparisons. Associations between psychological outcomes and leaking were assessed with t tests and Pearson correlations. Results Participants (N = 28) had been living with fistula for an average of 11 years. Baseline psychological distress was high, and decreased significantly at follow-up. Participants who self-reported continued incontinence at follow-up endorsed significantly higher PTSD and depression symptoms than those who reported being cured, and severity of leaking was associated with psychological distress. Conclusions Fistula patients experience improvements in mental health at 3 months after discharge, but these improvements are curtailed when women experience residual leaking. Given the rate of stress incontinence following surgery, it is important to prepare fistula patients for the possibility of incomplete cure and help them develop appropriate coping strategies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.; Mcwilliams, A.; Skidmore, E.
The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basismore » to extend that period. This paper describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior and leak performance. The CSR behavior of O-rings was evaluated at temperatures from 79 °C to 177 °C. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 75 °C). O-rings were also aged in Primary Containment Vessel (PCV) fixtures at temperatures ranging from 79 °C to 232 °C. The fixtures are helium leak tested periodically to determine if they remain leak-tight. The PCV fixture tests demonstrate that the 9975 O-rings will remain leak-tight at temperatures up to 149 °C for 3 years or more, and no leak failures have been observed with up to 8 years aging at 93 °C. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in the storage environment. The predictive model developed from the CSR data conservatively indicates a service life of more than 20 years at the bounding temperature of 75 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance to date.« less
Ueda, Kazuhiro; Kaneda, Yoshikazu; Sudo, Manabu; Mitsutaka, Jinbo; Li, Tao-Sheng; Suga, Kazuyoshi; Tanaka, Nobuyuki; Hamano, Kimikazu
2005-11-01
Emphysema is a well-known risk factor for developing air leak or persistent air leak after pulmonary resection. Although quantitative computed tomography (CT) and spirometry are used to diagnose emphysema, it remains controversial whether these tests are predictive of the duration of postoperative air leak. Sixty-two consecutive patients who were scheduled to undergo major lung resection for cancer were enrolled in this prospective study to define the best predictor of postoperative air leak duration. Preoperative factors analyzed included spirometric variables and area of emphysema (proportion of the low-attenuation area) that was quantified in a three-dimensional CT lung model. Chest tubes were removed the day after disappearance of the air leak, regardless of pleural drainage. Univariate and multivariate proportional hazards analyses were used to determine the influence of preoperative factors on chest tube time (air leak duration). By univariate analysis, site of resection (upper, lower), forced expiratory volume in 1 second, predicted postoperative forced expiratory volume in 1 second, and area of emphysema (< 1%, 1% to 10%, > 10%) were significant predictors of air leak duration. By multivariate analysis, site of resection and area of emphysema were the best independent determinants of air leak duration. The results were similar for patients with a smoking history (n = 40), but neither forced expiratory volume in 1 second nor predicted postoperative forced expiratory volume in 1 second were predictive of air leak duration. Quantitative CT is superior to spirometry in predicting air leak duration after major lung resection for cancer. Quantitative CT may aid in the identification of patients, particularly among those with a smoking history, requiring additional preventive procedures against air leak.
NASA Technical Reports Server (NTRS)
Hoadley, A. W.; Porter, A. J.
1991-01-01
The theory and experimental verification of a method of detecting fluid-mass loss, expansion-chamber pressure loss, or excessive vapor build-up in NASA's Airborne Information Management System (AIMS) are presented. The primary purpose of this leak-detection method is to detect the fluid-mass loss before the volume of vapor on the liquid side causes a temperature-critical part to be out of the liquid. The method detects the initial leak after the first 2.5 pct of the liquid mass has been lost, and it can be used for detecting subsequent situations including the leaking of air into the liquid chamber and the subsequent vapor build-up.
A risk-based approach to flammable gas detector spacing.
Defriend, Stephen; Dejmek, Mark; Porter, Leisa; Deshotels, Bob; Natvig, Bernt
2008-11-15
Flammable gas detectors allow an operating company to address leaks before they become serious, by automatically alarming and by initiating isolation and safe venting. Without effective gas detection, there is very limited defense against a flammable gas leak developing into a fire or explosion that could cause loss of life or escalate to cascading failures of nearby vessels, piping, and equipment. While it is commonly recognized that some gas detectors are needed in a process plant containing flammable gas or volatile liquids, there is usually a question of how many are needed. The areas that need protection can be determined by dispersion modeling from potential leak sites. Within the areas that must be protected, the spacing of detectors (or alternatively, number of detectors) should be based on risk. Detector design can be characterized by spacing criteria, which is convenient for design - or alternatively by number of detectors, which is convenient for cost reporting. The factors that influence the risk are site-specific, including process conditions, chemical composition, number of potential leak sites, piping design standards, arrangement of plant equipment and structures, design of isolation and depressurization systems, and frequency of detector testing. Site-specific factors such as those just mentioned affect the size of flammable gas cloud that must be detected (within a specified probability) by the gas detection system. A probability of detection must be specified that gives a design with a tolerable risk of fires and explosions. To determine the optimum spacing of detectors, it is important to consider the probability that a detector will fail at some time and be inoperative until replaced or repaired. A cost-effective approach is based on the combined risk from a representative selection of leakage scenarios, rather than a worst-case evaluation. This means that probability and severity of leak consequences must be evaluated together. In marine and offshore facilities, it is conventional to use computational fluid dynamics (CFD) modeling to determine the size of a flammable cloud that would result from a specific leak scenario. Simpler modeling methods can be used, but the results are not very accurate in the region near the release, especially where flow obstructions are present. The results from CFD analyses on several leak scenarios can be plotted to determine the size of a flammable cloud that could result in an explosion that would generate overpressure exceeding the strength of the mechanical design of the plant. A cloud of this size has the potential to produce a blast pressure or flying debris capable of causing a fatality or subsequent damage to vessels or piping containing hazardous material. In cases where the leak results in a fire, rather than explosion, CFD or other modeling methods can estimate the size of a leak that would cause a fire resulting in subsequent damage to the facility, or would prevent the safe escape of personnel. The gas detector system must be capable of detecting a gas release or vapor cloud, and initiating action to prevent the leak from reaching a size that could cause injury or severe damage upon ignition.
Nonintrusive diagnosis of premature ruptured amniotic membranes using a novel polymer.
Bornstein, Jacob; Geva, Adam; Solt, Ido; Fait, Vladimir; Schoenfeld, Alex; Shoham, Hadar Kessary; Sobel, Jack
2006-08-01
This article describes the evaluation of the diagnostic efficacy of AL-SENSE panty-liner in detecting premature rupture of membranes (PROM). One hundred and three women attending the labor and delivery ward were enrolled into three groups: women presenting with a vaginal leak of fluid who had not yet been examined; women with overt PROM, and women with no fluid leak. The result of the AL-SENSE strip test was compared with the clinical diagnosis, which was based on direct visualization of the posterior vaginal fornix and cervix, crystallization, and nitrazine tests. AL-SENSE panty-liner test had a sensitivity of 100% and a specificity of 75% in detecting PROM, with an overall agreement of 82.35% between the AL-SENSE test result and the clinical diagnosis. AL-SENSE may be used as a reliable test to rule out PROM and as an effective device to diagnose PROM and differentiate it from urine leak and vulvovaginal candidiasis.
NASA Technical Reports Server (NTRS)
Russell, John M.
1993-01-01
This is the final report of a research effort which addresses the title problem. The report discusses two broad models of flows, which represent the following extreme cases: (1) inertia-dominated flow, where friction is relatively insignificant; and (2) friction-dominated flow where inertia is insignificant. In class (2), the leak channel might consist of the gap between a scratch in a plastic seal and a polished metal plate against which the seal is pressed. Here, the cross section of the leak channel is modeled as a flat bottomed crescent. A publication generated under the present grant period presents an exact solution of the equations of fully-developed laminar pipe flow of a liquid in the case of a crescent beneath a hyperbolic arc. A Master's thesis project supported by the present grant presents the corresponding solution beneath a circular arc. A second publication reviews the flow of a gas through the same channel, which may be analyzed by a standard one-dimensional model (Fanno flow) for an engineering approximation. Finally, the report discusses the design and progress in the fabrication of a leak-test cell, in which one may measure the flow of fluid through a controlled flaw in a seal. The aim of such measurements is to furnish data for comparison with the predictions of the theory.
ERIC Educational Resources Information Center
Bednar, Barbara A.
1990-01-01
The harm to human health and our environment caused by leaking underground storage tanks can be devastating. Schools can meet new federal waste management standards by instituting daily inventory monitoring, selecting a reliable volumetric testing company, locating and repairing leaks promptly, and removing and installing tanks appropriately. (MLH)
1999-02-23
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building's high bay, the Rotation Handling Fixture (RHF), with a simulated module attached, is lowered by crane into the altitude chamber below during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, depositing it into the altitude chamber for leak testing. The chamber was recently reactivated after a 24-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
1999-02-23
KENNEDY SPACE CENTER, FLA. -- Viewed from inside the altitude chamber in the Operations and Checkout Building's high bay, the Rotation Handling Fixture (RHF), with a simulated module attached, is lowered during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, depositing it into the altitude chamber for leak testing. The chamber was recently reactivated after a 24-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
1999-02-23
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building's high bay, a crane lifts the Rotation Handling Fixture (RHF) and simulated module during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, lifting it up and into an altitude chamber for leak testing. The chamber was recently reactivated after a 24-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability
Hunsbedt, A.; Boardman, C.E.
1995-04-11
A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor is disclosed. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo`s structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated. 5 figures.
Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability
Hunsbedt, Anstein; Boardman, Charles E.
1995-01-01
A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo's structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated.
40 CFR 52.1120 - Identification of plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... a new regulation 310 CMR 7.19 “Interim Sulfur-in-Fuel Limitations for Fossil Fuel Utilization... May 22, 1985, including Method 27, record form, potential leak points, major tank truck leak sources...
40 CFR 52.1120 - Identification of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... a new regulation 310 CMR 7.19 “Interim Sulfur-in-Fuel Limitations for Fossil Fuel Utilization... May 22, 1985, including Method 27, record form, potential leak points, major tank truck leak sources...
40 CFR 52.1120 - Identification of plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... a new regulation 310 CMR 7.19 “Interim Sulfur-in-Fuel Limitations for Fossil Fuel Utilization... May 22, 1985, including Method 27, record form, potential leak points, major tank truck leak sources...
40 CFR 52.1120 - Identification of plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... a new regulation 310 CMR 7.19 “Interim Sulfur-in-Fuel Limitations for Fossil Fuel Utilization... May 22, 1985, including Method 27, record form, potential leak points, major tank truck leak sources...
40 CFR 52.1120 - Identification of plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... a new regulation 310 CMR 7.19 “Interim Sulfur-in-Fuel Limitations for Fossil Fuel Utilization... May 22, 1985, including Method 27, record form, potential leak points, major tank truck leak sources...
Postoperative esophageal leak management with the Polyflex esophageal stent.
Freeman, Richard K; Ascioti, Anthony J; Wozniak, Thomas C
2007-02-01
Leak after esophageal anastomosis or perforation repair prolongs hospitalization, prevents oral hydration and nutrition, and can produce localized infection or sepsis. This investigation reviews our experience treating postoperative esophageal leaks with the Polyflex esophageal stent (Boston Scientific, Natick, Mass). Over a 30-month period, patients with a postoperative esophageal leak were treated with the Polyflex stent for leak occlusion. Leak occlusion was confirmed by means of esophagraphy. Patients were followed until their stent was removed and their esophageal leak had resolved. Twenty-one patients had 27 stents placed for leak occlusion after esophagectomy (n = 5), esophageal perforation (n = 5), surgical (n = 4) or endoscopic (n = 2) antireflux procedure, and esophageal diverticulectomy (n = 3) or myotomy (n = 2). The mean interval between surgical intervention and stent placement was 12 +/- 8 days (range, 3-31 days). Occlusion of the leak occurred in 20 patients. One patient experienced a dehiscence of the surgical esophageal perforation repair requiring esophageal diversion. Stent migration requiring repositioning (n = 3) or replacement (n = 4) occurred in 5 (24%) patients. Twenty (95%) stents were removed without residual leak (mean, 51 +/- 43 days; range, 15-175 days). One patient had a stricture after stent removal that required endoscopic dilatation. One patient in this series died. The Polyflex esophageal stent is an effective method for occluding a postoperative esophageal leak. It rapidly eliminates contamination of the mediastinum, pleura, and peritoneum; allows oral hydration and nutrition; and is easily removable. These stents also offer an appealing alternative to traditional esophageal diversion and subsequent reconstruction in patients with a persistent esophageal leak.
The Diagnostic Value of Routine Contrast Esophagram in Anastomotic Leaks After Esophagectomy.
Hu, Zhongwu; Wang, Xiaowe; An, Xush; Li, Wenjin; Feng, Yun; You, Zhenbing
2017-08-01
Routine contrast esophagram has been shown to be increasingly limited in diagnosing anastomotic leaks after esophagectomy. Patients undergoing esophagectomy from 2013 to 2014 at Huai'an First Peoples' Hospital were identified. We retrospectively analyzed patients who underwent routine contrast esophagram on postoperative day 7 (range 6-10) to preclude anastomotic leaks after esophagectomy. In 846 patients who underwent esophagectomy, a cervical anastomosis was performed in 286 patients and an intrathoracic anastomosis in 560 patients. There were 57 (6.73%) cases with anastomotic leaks, including cervical leaks in 36 and intrathoracic leaks in 21 patients. In the cervical anastomotic leak patients, 13 were diagnosed by early local clinical symptoms and 23 underwent routine contrast esophagram. There were 7 (30.4%) true-positive, 11 (47.8%) false-negative, and five (21.8%) equivocal cases. In the intrathoracic anastomotic leak patients, four (19%) were diagnosed by clinical symptoms, 16 (76.2%) were true positives, and one (4.8%) was a false negative. Aspiration occurred in five patients with cervical anastomoses and in eight patients with intrathoracic anastomoses; aspiration pneumonitis did not occur in these cases. Gastrografin and barium are safe contrast agents to use in post-esophagectomy contrast esophagram. Because of the low sensitivity in detecting cervical anastomotic leaks, routine contrast esophagram is not advised. For patients with intrathoracic anastomoses, it is still an effective method for detecting anastomotic leaks.
Filosso, P L; Ruffini, E; Solidoro, P; Molinatti, M; Bruna, M C; Oliaro, A
2010-06-01
Prolonged air leaks remain one of the most important complication after pulmonary resection. The aim of this study was to test a new fast-track chest tube removal protocol using a new drainage system, which digitally records postoperative air leaks, compared to the traditional one, with subjective visual air leak assessment. Patients with moderate COPD undergoing lobectomy for primary lung cancer at the Department of Thoracic Surgery of the University of Torino were randomised in two groups with different chest drainage systems and different removal protocols: in Group A the drainage was removed after digitally recordered measurement of air leaks; in Group B the tube was removed according to the air leaks visualization by bubbling in the water column. The following variables were evaluated: first and second drainage removal day; overall hospital length of stay; overall hospitalization costs. First and second drainages were removed sooner in those patients with the digital drainage system. An earlier drainage removal is associated with significative reduction in hospital length of stay and overall hospitalization costs. The digital and continuous air leak measurement reduces the hospital length of stay by a more accurate and reproductive air leaks measurement. Further studies are mandatory to corroborate our preliminary results.
Large-Scale Liquid Hydrogen Testing of Variable Density Multilayer Insulation with a Foam Substrate
NASA Technical Reports Server (NTRS)
Martin, J. J.; Hastings, L.
2001-01-01
The multipurpose hydrogen test bed (MHTB), with an 18-cu m liquid hydrogen tank, was used to evaluate a combination foam/multilayer combination insulation (MLI) concept. The foam element (Isofoam SS-1171) insulates during ground hold/ascent flight, and allowed a dry nitrogen purge as opposed to the more complex/heavy helium purge subsystem normally required. The 45-layer MLI was designed for an on-orbit storage period of 45 days. Unique WI features include a variable layer density, larger but fewer double-aluminized Mylar perforations for ascent to orbit venting, and a commercially established roll-wrap installation process that reduced assembly man-hours and resulted in a roust, virtually seamless MLI. Insulation performance was measured during three test series. The spray-on foam insulation (SOFI) successfully prevented purge gas liquefaction within the MLI and resulted in the expected ground hold heat leak of 63 W/sq m. The orbit hold tests resulted in heat leaks of 0.085 and 0.22 W/sq m with warm boundary temperatures of 164 and 305 K, respectively. Compared to the best previously measured performance with a traditional MLI system, a 41-percent heat leak reduction with 25 fewer MLI layers was achieved. The MHTB MLI heat leak is half that calculated for a constant layer density MLI.
Electrical detection of liquid lithium leaks from pipe joints.
Schwartz, J A; Jaworski, M A; Mehl, J; Kaita, R; Mozulay, R
2014-11-01
A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, R.N.; Goodrich, R.W.
1991-03-01
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 {plus_minus} 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 {plus_minus} 0.7, {minus}0.4 {plus_minus} 0.3, and 76 {plus_minus} 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone testmore » facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on {Delta}p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc. 13 refs.« less
NASA Astrophysics Data System (ADS)
Rabe, Paul; Browne, Keith; Brink, Janus; Coetzee, Christiaan J.
2016-07-01
MonoEthylene glycol coolant is used extensively on the Southern African Large Telescope to cool components inside the telescope chamber. To prevent coolant leaks from causing serious damage to electronics and optics, a Glycol Leak Detection System was designed to automatically shut off valves in affected areas. After two years of research and development the use of leaf wetness sensors proved to work best and is currently operational. These sensors are placed at various critical points within the instrument payload that would trigger the leak detector controller, which closes the valves, and alerts the building management system. In this paper we describe the research of an initial concept and the final accepted implementation and the test results thereof.
Daily, William D.; Laine, Daren L.; Laine, Edwin F.
2001-01-01
Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner or between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid through the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution.
Daily, William D.; Laine, Daren L.; Laine, Edwin F.
1997-01-01
Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid though the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution.
Daily, W.D.; Laine, D.L.; Laine, E.F.
1997-08-26
Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid though the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution. 6 figs.
Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo
2017-04-01
Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.
Park, Jae Kil; Kim, Jae Jun; Moon, Seok Whan
2017-10-01
Anastomotic leak is one of most significant causes of mortality after esophagectomy. Therefore, it is clinically valuable to detect anastomotic leak early after esophagectomy in esophageal cancer. The purpose of this study is to investigate the associations between routine postoperative laboratory findings and anastomotic leak and to analyze the laboratory findings to find out an independent predictive marker for anastomotic leak. In addition, this study compares cases treated with neoadjuvant therapy (NT) and those without (non-NT). We retrospectively assessed the medical records of 201 consecutive cases that met this study's criteria from January 2009 to December 2016. All patients underwent curative and complete esophagectomy for intra-thoracic esophageal cancer. We compiled and analyzed routine laboratory findings from the day before surgery to the eighth postoperative day on a daily basis. Routine laboratory tests consisted of 26 separate tests, including complete blood cell counts, blood chemistries, as well as erythrocyte sedimentation rate and C-reactive protein (CRP). Barium esophagogram with chest computed tomography (CT) was performed on the seventh postoperative day to evaluate the presence of an anastomotic leak. A total of 45 of 201 patients underwent NT. Anastomotic leaks were found in 23 (11.4%) of 201 patients (8 patients in NT and 15 patients in non-NT). White blood cell (WBC) from the second postoperative day (P=0.031, P=0.006, P=0.007, P=0.007, P=0.041, and P=0.003, respectively) and CRP from the third postoperative day (P=0.012, P<0.001, P=0.014, P<0.001, P=0.001, and P=0.006, respectively) were associated with anastomotic leak in non-NT; however, only CRP on the third, fifth, sixth, and seventh postoperative days (P=0.041, P=0.037, P=0.002, and P=0.003, respectively) was associated with anastomotic leak in NT. The CRP level on the third postoperative day was a significant independent predictive marker of anastomotic leak (P=0.041, odd ratio (OR) 1.056, 95% confidential interval (CI): 1.002-1.113) and had a significant diagnostic cutoff value for the development of anastomotic leak (non-NT: cutoff value 17.12 mg/dL, sensitivity 69.2%, specificity 78.1%, P<0.001, area 0.822; NT: cutoff value 16.42 mg/dL, sensitivity 80.0%, specificity 70.0%, P=0.042, area 0.7104). There were divergent laboratory findings reflective of anastomotic leak between patients who underwent NT and those who did not. The CRP level on the third postoperative day had a significant cutoff value for early detection of anastomotic leak after esophagectomy in both NT and non-NT groups.
Creutz, E.C.; McAdams, Wm.A.; Foss, M.H.
1958-07-22
A method is described for detecting minute holes In fuel element jackets. The method comprises submerging the jacketed body in an atmosphere of a radioactive gas under pressure, the radioactive emanations from said gas being sufficientiy penetratIng to penetrate the jacket of the jacketed body. After the jacketed body is removed from the radtoactive gas atmosphere, it is exannined for the presence of emanations from radioactive gas which entered the jacketed body through the minute holes. In this manner, the detectton of radioactive emanations is a positive indication that the fuel element is not perfectly sealed.
Materials and methods for preventing and treating anastomotic leaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alverdy, John C.
Materials and methods for preventing and treating anastomotic leaks are disclosed. Data establishes that pathogenic microbes interfere with establishing epithelial cell barriers in anastomoses and, more generally, with the reconnection of any two portions of like or different tissues comprising epithelia. Suitable prophylactic and therapeutic composition comprise, e.g., a phosphorylated high molecular weight polyethylene glycol compound.
Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes
NASA Technical Reports Server (NTRS)
Mills, R. C., Sr.; Duesberg, J.
1986-01-01
Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.
Methane emissions from underground pipeline leaks remain an ongoing issue in the development of accurate methane emission inventories for the natural gas supply chain. Application of mobile methods during routine street surveys would help address this issue, but there are large ...
PCR-Based Method for Detecting Viral Penetration of Medical Exam Gloves
Broyles, John M.; O'Connell, Kevin P.; Korniewicz, Denise M.
2002-01-01
The test approved by the U.S. Food and Drug Administration for assessment of the barrier quality of medical exam gloves includes visual inspection and a water leak test. Neither method tests directly the ability of gloves to prevent penetration by microorganisms. Methods that use microorganisms (viruses and bacteria) to test gloves have been developed but require classical culturing of the organism to detect it. We have developed a PCR assay for bacteriophage φX174 that allows the rapid detection of penetration of gloves by this virus. The method is suitable for use with both latex and synthetic gloves. The presence of glove powder on either latex or synthetic gloves had no effect on the ability of the PCR assay to detect bacteriophage DNA. The assay is rapid, sensitive, and inexpensive; requires only small sample volumes; and can be automated. PMID:12149320
Methodology, status and plans for development and assessment of the code ATHLET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teschendorff, V.; Austregesilo, H.; Lerchl, G.
1997-07-01
The thermal-hydraulic computer code ATHLET (Analysis of THermal-hydraulics of LEaks and Transients) is being developed by the Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) for the analysis of anticipated and abnormal plant transients, small and intermediate leaks as well as large breaks in light water reactors. The aim of the code development is to cover the whole spectrum of design basis and beyond design basis accidents (without core degradation) for PWRs and BWRs with only one code. The main code features are: advanced thermal-hydraulics; modular code architecture; separation between physical models and numerical methods; pre- and post-processing tools; portability. The codemore » has features that are of special interest for applications to small leaks and transients with accident management, e.g. initialization by a steady-state calculation, full-range drift-flux model, dynamic mixture level tracking. The General Control Simulation Module of ATHLET is a flexible tool for the simulation of the balance-of-plant and control systems including the various operator actions in the course of accident sequences with AM measures. The code development is accompained by a systematic and comprehensive validation program. A large number of integral experiments and separate effect tests, including the major International Standard Problems, have been calculated by GRS and by independent organizations. The ATHLET validation matrix is a well balanced set of integral and separate effects tests derived from the CSNI proposal emphasizing, however, the German combined ECC injection system which was investigated in the UPTF, PKL and LOBI test facilities.« less
Thermal-leak analyzer for vacuum-jacketed lines
NASA Technical Reports Server (NTRS)
Heisman, R. M.; Iceland, W. F.; Ruppe, E. P.
1978-01-01
Technique involves coating suspected area with water-soluble black paint that gives even, infrared emission. Painted area is warmed with heat gun; an infrared scanner is used to detect cooled spot on jacket exterior. Introduction of atmospheric pressure into jacket intensifies leak jet and improves test sensitivity.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... Production Act of 1993--Cooperative Research Group on Evaluation of Distributed Leak Detection Systems... Institute-- Cooperative Research Group on Evaluation of Distributed Leak Detection Systems--Performance... detection systems for offshore pipelines. Laboratory testing of distributed temperature and distributed...
VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME I
A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems whe...
Leaking in history space: A way to analyze systems subjected to arbitrary driving
NASA Astrophysics Data System (ADS)
Kaszás, Bálint; Feudel, Ulrike; Tél, Tamás
2018-03-01
Our aim is to unfold phase space structures underlying systems with a drift in their parameters. Such systems are non-autonomous and belong to the class of non-periodically driven systems where the traditional theory of chaos (based e.g., on periodic orbits) does not hold. We demonstrate that even such systems possess an underlying topological horseshoe-like structure at least for a finite period of time. This result is based on a specifically developed method which allows to compute the corresponding time-dependent stable and unstable foliations. These structures can be made visible by prescribing a certain type of history for an ensemble of trajectories in phase space and by analyzing the trajectories fulfilling this constraint. The process can be considered as a leaking in history space—a generalization of traditional leaking, a method that has become widespread in traditional chaotic systems, to leaks depending on time.
NASA Technical Reports Server (NTRS)
Garafolo, Nicholas G.; Daniels, Christopher C.
2011-01-01
A novel docking seal was developed for the main interface seal of NASA s Low Impact Docking System (LIDS). This interface seal was designed to maintain acceptable leak rates while being exposed to the harsh environmental conditions of outer space. In this experimental evaluation, a candidate docking seal assembly called Engineering Development Unit (EDU58) was characterized and evaluated against the Constellation Project leak rate requirement. The EDU58 candidate seal assembly was manufactured from silicone elastomer S0383-70 vacuum molded in a metal retainer ring. Four seal designs were considered with unique characteristic heights. The leak rate performance was characterized through a mass point leak rate method by monitoring gas properties within an internal control volume. The leakage performance of the seals were described herein at representative docking temperatures of -50, +23, and +50 C for all four seal designs. Leak performance was also characterized at 100, 74, and 48 percent of full closure. For all conditions considered, the candidate seal assemblies met the Constellation Project leak rate requirement.
Microfabricated Hydrogen Sensor Technology for Aerospace and Commercial Applications
NASA Technical Reports Server (NTRS)
Hunter, Gary W.; Bickford, R. L.; Jansa, E. D.; Makel, D. B.; Liu, C. C.; Wu, Q. H.; Powers, W. T.
1994-01-01
Leaks on the Space Shuttle while on the Launch Pad have generated interest in hydrogen leak monitoring technology. An effective leak monitoring system requires reliable hydrogen sensors, hardware, and software to monitor the sensors. The system should process the sensor outputs and provide real-time leak monitoring information to the operator. This paper discusses the progress in developing such a complete leak monitoring system. Advanced microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC) and Gencorp Aerojet (Aerojet). Changes in the hydrogen concentrations are detected using a PdAg on silicon Schottky diode structure. Sensor temperature control is achieved with a temperature sensor and heater fabricated onto the sensor chip. Results of the characterization of these sensors are presented. These sensors can detect low concentrations of hydrogen in inert environments with high sensitivity and quick response time. Aerojet is developing the hardware and software for a multipoint leak monitoring system designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Work has commenced on integrating the NASA LeRC-CWRU hydrogen sensors with the Aerojet designed monitoring system. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. Possible commercialization of the system will also be discussed.
USDA-ARS?s Scientific Manuscript database
The presence of Norovirus (NV) in watersheds in the vicinity of raw produce production is a concern. This could occur due to leaking septic systems, improper RV waste removal, improperly treated recycled wastewater, or other unknown factors. We used a qRT-PCR method to test for NV in rinsates from M...
Pompili, Cecilia; Falcoz, Pierre Emmanuel; Salati, Michele; Szanto, Zalan; Brunelli, Alessandro
2017-04-01
The study objective was to develop an aggregate risk score for predicting the occurrence of prolonged air leak after video-assisted thoracoscopic lobectomy from patients registered in the European Society of Thoracic Surgeons database. A total of 5069 patients who underwent video-assisted thoracoscopic lobectomy (July 2007 to August 2015) were analyzed. Exclusion criteria included sublobar resections or pneumonectomies, lung resection associated with chest wall or diaphragm resections, sleeve resections, and need for postoperative assisted mechanical ventilation. Prolonged air leak was defined as an air leak more than 5 days. Several baseline and surgical variables were tested for a possible association with prolonged air leak using univariable and logistic regression analyses, determined by bootstrap resampling. Predictors were proportionally weighed according to their regression estimates (assigning 1 point to the smallest coefficient). Prolonged air leak was observed in 504 patients (9.9%). Three variables were found associated with prolonged air leak after logistic regression: male gender (P < .0001, score = 1), forced expiratory volume in 1 second less than 80% (P < .0001, score = 1), and body mass index less than 18.5 kg/m 2 (P < .0001, score = 2). The aggregate prolonged air leak risk score was calculated for each patient by summing the individual scores assigned to each variable (range, 0-4). Patients were then grouped into 4 classes with an incremental risk of prolonged air leak (P < .0001): class A (score 0 points, 1493 patients) 6.3% with prolonged air leak, class B (score 1 point, 2240 patients) 10% with prolonged air leak, class C (score 2 points, 1219 patients) 13% with prolonged air leak, and class D (score >2 points, 117 patients) 25% with prolonged air leak. An aggregate risk score was created to stratify the incidence of prolonged air leak after video-assisted thoracoscopic lobectomy. The score can be used for patient counseling and to identify those patients who can benefit from additional intraoperative preventative measures. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Two different sensor technologies and their properties were analyzed. he nalysis simulated a leak which occurs from an underground storage tank. igaro gas sensors and the Adsistor gas sensor were tested in simulated underground storage tank nvironments using the Carnegie Mellon R...
24 CFR 3280.612 - Tests and inspection.
Code of Federal Regulations, 2010 CFR
2010-04-01
... leaks. Then the system shall be unplugged and emptied. The waste piping above the level of the water... water and checking for leaks and retarded flow while they are being emptied. (d) Shower compartments... and inspection. (a) Water system. All water piping in the water distribution system shall be subjected...
10 CFR 32.59 - Same: Leak testing of each source.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS... kilobecquerels (0.1 microcurie) of americium-241 or radium-226 before transferring the source to a general... leaking or losing americium-241 or radium-226 and shall not be transferred to a general licensee under...
10 CFR 32.59 - Same: Leak testing of each source.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS... kilobecquerels (0.1 microcurie) of americium-241 or radium-226 before transferring the source to a general... leaking or losing americium-241 or radium-226 and shall not be transferred to a general licensee under...
Failure analysis of fuze power supply
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menke, J.T.
1996-10-01
Batteries in storage which were used in electronic fuzes were found to be leaking after 5 years. The leaking battery ampules were made of copper and contained mixture of fluoboric acid and methylene bromide. The corrosion mechanism is described along with the testing/analysis required to simulate the field failures.
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
Dulce, Raul A; Mayo, Vera; Rangel, Erika B; Balkan, Wayne; Hare, Joshua M
2015-01-02
Although nitric oxide (NO) signaling modulates cardiac function and excitation-contraction coupling, opposing results because of inconsistent experimental conditions, particularly with respect to temperature, confound the ability to elucidate NO signaling pathways. Here, we show that temperature significantly modulates NO effects. To test the hypothesis that temperature profoundly affects nitroso-redox equilibrium, thereby affecting sarcoplasmic reticulum (SR) calcium (Ca(2+)) leak. We measured SR Ca(2+) leak in cardiomyocytes from wild-type (WT), NO/redox imbalance (neuronal nitric oxide synthase-deficient mice-1 [NOS1(-/-)]), and hyper S-nitrosoglutathione reductase-deficient (GSNOR(-/-)) mice. In WT cardiomyocytes, SR Ca(2+) leak increased because temperature decreased from 37°C to 23°C, whereas in NOS1(-/-) cells, the leak suddenly increased when the temperature surpassed 30°C. GSNOR(-/-) cardiomyocytes exhibited low leak throughout the temperature range. Exogenously added NO had a biphasic effect on NOS1(-/-) cardiomyocytes; reducing leak at 37°C but increasing it at subphysiological temperatures. Oxypurinol and Tempol diminished the leak in NOS1(-/-) cardiomyocytes. Cooling from 37°C to 23°C increased reactive oxygen species generation in WT but decreased it in NOS1(-/-) cardiomyocytes. Oxypurinol further reduced reactive oxygen species generation. At 23°C in WT cells, leak was decreased by tetrahydrobiopterin, an essential NOS cofactor. Cooling significantly increased SR Ca(2+) content in NOS1(-/-) cells but had no effect in WT or GSNOR(-/-). Ca(2+) leak and temperature are normally inversely proportional, whereas NOS1 deficiency reverses this effect, increasing leak and elevating reactive oxygen species production because temperature increases. Reduced denitrosylation (GSNOR deficiency) eliminates the temperature dependence of leak. Thus, temperature regulates the balance between NO and reactive oxygen species which in turn has a major effect on SR Ca(2+). © 2014 American Heart Association, Inc.
Experimental evaluation of three leak detection and location concepts for space stations
NASA Technical Reports Server (NTRS)
Scherb, M. V.; Kazokas, G. P.; Zelik, J. A.; Mastandrea, J. R.; Mackallor, D. C.
1972-01-01
Three leak (or precursor damage modes) detection and location concepts for space station overboard leakage were evaluated experimentally. The techniques are: (1) static and dynamic seal leak detector sensing of moisture or all gases in space cabin atmosphere, (2) active ultrasonic Lamb-wave detection of flaws or cracks in cabin wall, and (3) impact gage detection of stress waves induced in cabin pressure wall by meteoroid or orbital impact. The experimental results obtained in the program demonstrated that all three leak detection and location concepts are feasible. With further development, the methods can be integrated into an effective damage control system for advanced manned earth-orbital systems.
NASA Astrophysics Data System (ADS)
Kashiwabara, Takahito
Strong solutions of the non-stationary Navier-Stokes equations under non-linearized slip or leak boundary conditions are investigated. We show that the problems are formulated by a variational inequality of parabolic type, to which uniqueness is established. Using Galerkin's method and deriving a priori estimates, we prove global and local existence for 2D and 3D slip problems respectively. For leak problems, under no-leak assumption at t=0 we prove local existence in 2D and 3D cases. Compatibility conditions for initial states play a significant role in the estimates.
Cerebrospinal fluid otorhinorrhea due to cochlear dysplasias.
Syal, Rajan; Tyagi, Isha; Goyal, Amit
2005-07-01
Cochlear dysplasia associated with defect in stapes footplate can be a cause of cerebrospinal fluid leak. Repair of cerebrospinal fluid leak in these cases is usually done by packing the vestibule with muscle or fascia. This traditional method of repair has 30-60% failure rate. Cerebrospinal fluid leak in four such patients was successfully repaired using multiple layer packing of vestibule, reinforced by pedicle temporalis muscle graft. Intraoperatively continuous lumbar drain was done. Magnetic resonance imaging of inner ear using 3D FSE T2WI and 3D FIESTA sequences was found helpful noninvasive investigation to localize site and route of cerebrospinal fluid leak.
Methane Leak Detection and Emissions Quantification with UAVs
NASA Astrophysics Data System (ADS)
Barchyn, T.; Fox, T. A.; Hugenholtz, C.
2016-12-01
Robust leak detection and emissions quantification algorithms are required to accurately monitor greenhouse gas emissions. Unmanned aerial vehicles (UAVs, `drones') could both reduce the cost and increase the accuracy of monitoring programs. However, aspects of the platform create unique challenges. UAVs typically collect large volumes of data that are close to source (due to limited range) and often lower quality (due to weight restrictions on sensors). Here we discuss algorithm development for (i) finding sources of unknown position (`leak detection') and (ii) quantifying emissions from a source of known position. We use data from a simulated leak and field study in Alberta, Canada. First, we detail a method for localizing a leak of unknown spatial location using iterative fits against a forward Gaussian plume model. We explore sources of uncertainty, both inherent to the method and operational. Results suggest this method is primarily constrained by accurate wind direction data, distance downwind from source, and the non-Gaussian shape of close range plumes. Second, we examine sources of uncertainty in quantifying emissions with the mass balance method. Results suggest precision is constrained by flux plane interpolation errors and time offsets between spatially adjacent measurements. Drones can provide data closer to the ground than piloted aircraft, but large portions of the plume are still unquantified. Together, we find that despite larger volumes of data, working with close range plumes as measured with UAVs is inherently difficult. We describe future efforts to mitigate these challenges and work towards more robust benchmarking for application in industrial and regulatory settings.
Autogenous Metallic Pipe Leak Repair in Potable Water Systems.
Tang, Min; Triantafyllidou, Simoni; Edwards, Marc A
2015-07-21
Copper and iron pipes have a remarkable capability for autogenous repair (self-repair) of leaks in potable water systems. Field studies revealed exemplars that metallic pipe leaks caused by nails, rocks, and erosion corrosion autogenously repaired, as confirmed in the laboratory experiments. This work demonstrated that 100% (N = 26) of 150 μm leaks contacting representative bulk potable water in copper pipes sealed autogenously via formation of corrosion precipitates at 20-40 psi, pH 3.0-11.0, and with upward and downward leak orientations. Similar leaks in carbon steel pipes at 20 psi self-repaired at pH 5.5 and 8.5, but two leaks did not self-repair permanently at pH 11.0 suggesting that water chemistry may control the durability of materials that seal the leaks and therefore the permanence of repair. Larger 400 μm holes in copper pipes had much lower (0-33%) success of self-repair at pH 3.0-11.0, whereas all 400 μm holes in carbon steel pipes at 20 psi self-repaired at pH 4.0-11.0. Pressure tests indicated that some of the repairs created at 20-40 psi ambient pressure could withstand more than 100 psi without failure. Autogenous repair has implications for understanding patterns of pipe failures, extending the lifetime of decaying infrastructure, and developing new plumbing materials.
Kul, Melahat; Erden, Ayşe; Düşünceli Atman, Ebru
2017-04-01
To assess the diagnostic value of dynamic T 1 weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks. A total of 28 patients with suspected biliary leakage who underwent routine T 2 weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images. In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p < 0.001). 19 of 28 patients had bile leak findings in T1w Gd-EOB-DTPA-enhanced MRC [HBP group: N = 7 (36.8%), DP group: N = 12 (63.2%)]. There was no statistically significant difference in terms of laboratory test results and the presence of bile duct dilatation between HBP and DP group (p > 0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters. Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.
Remote Leak Detection: Indirect Thermal Technique
NASA Technical Reports Server (NTRS)
Clements, Sandra
2002-01-01
Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-14
... ID number EPA-HQ- OECA-2010-0357, to (1) EPA online using www.regulations.gov (our preferred method... leaking equipment, repair methods used to stop the leaks, and dates of repair. The time period for this... correction of a mathematical error. There are no annual capital and O&M costs to the regulated entities...
The use of a water seal to manage air leaks after a pulmonary lobectomy: a retrospective study.
Okamoto, Junichi; Okamoto, Tatsuro; Fukuyama, Yasuro; Ushijima, Chie; Yamaguchi, Masafumi; Ichinose, Yukito
2006-08-01
The methods for managing chest drainage tubes during the postoperative period differ among thoracic surgeons and, as a result, the optimal method remains controversial. We reviewed 170 consecutive patients undergoing a pulmonary lobectomy for either primary lung cancer or metastatic lung cancer from January 1998 to December 2002. After the operation, the chest drainage tube was placed on a suction pump with a negative pressure of -10 cmH(2)O in 120 patients before 2001, while such drainage tubes were kept on water seal in 47 cases mainly since 2001. Regarding the preoperative and postoperative variables, postoperative air leak as well as the video-assisted thoracic surgery (VATS) procedure were more frequently observed in the water seal group than in the suction group (p=0.01580, p<0.001, respectively). In comparing these different populations, each Kaplan-Meier curve, which presented the duration of the postoperative air leak seemed to be similar between the two methods. These observations suggest that applying chest tubes on water seal seems to be an effective method for preventing postoperative air leak in clinical practice. However, a prospective randomized trial using a larger series of patients is warranted for this subject.
1999-02-23
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building's high bay, the Rotation Handling Fixture (RHF), with a simulated module attached, is viewed from above the altitude chamber into which it was lowered during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, depositing it into the altitude chamber for leak testing. The chamber was recently reactivated after a 20-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
Sun, Da-Xin; Tan, Xiao-Dong; Gao, Feng; Xu, Jin; Cui, Dong-Xu; Dai, Xian-Wei
2015-01-01
Background Postoperative bile leak is a major surgical morbidity after curative resection with hepaticojejunostomy for hilar cholangiocarcinoma, especially in Bismuth-Corlette types III and IV. This retrospective study assessed the effectiveness and safety of an autologous hepatic round ligament flap (AHRLF) for reducing bile leak after hilar hepaticojejunostomy. Methods Nine type III and IV hilar cholangiocarcinoma patients were consecutively hospitalized for elective perihilar partial hepatectomy with hilar hepaticojejunostomy using an AHRLF between October 2009 and September 2013. The AHRLF was harvested to reinforce the perihilar hepaticojejunostomy. Main outcome measures included operative time, blood loss, postoperative recovery times, morbidity, bile leak, R0 resection rate, and overall survival. Results All patients underwent uneventful R0 resection with hilar hepaticojejunostomy. No patient experienced postoperative bile leak. Conclusions The AHRLF was associated with lack of bile leak after curative perihilar hepatectomy with hepaticojejunostomy for hilar cholangiocarcinoma, without compromising oncologic safety, and is recommended in selected patients. PMID:25938440
Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor
NASA Astrophysics Data System (ADS)
Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.
2017-04-01
Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.
NASA Astrophysics Data System (ADS)
Dye, S. A.; Johnson, W. L.; Plachta, D. W.; Mills, G. L.; Buchanan, L.; Kopelove, A. B.
2014-11-01
Improvements in cryogenic propellant storage are needed to achieve reduced or Zero Boil Off of cryopropellants, critical for long duration missions. Techniques for reducing heat leak into cryotanks include using passive multi-layer insulation (MLI) and vapor cooled or actively cooled thermal shields. Large scale shields cannot be supported by tank structural supports without heat leak through the supports. Traditional MLI also cannot support shield structural loads, and separate shield support mechanisms add significant heat leak. Quest Thermal Group and Ball Aerospace, with NASA SBIR support, have developed a novel Load Bearing multi-layer insulation (LBMLI) capable of self-supporting thermal shields and providing high thermal performance. We report on the development of LBMLI, including design, modeling and analysis, structural testing via vibe and acoustic loading, calorimeter thermal testing, and Reduced Boil-Off (RBO) testing on NASA large scale cryotanks. LBMLI uses the strength of discrete polymer spacers to control interlayer spacing and support the external load of an actively cooled shield and external MLI. Structural testing at NASA Marshall was performed to beyond maximum launch profiles without failure. LBMLI coupons were thermally tested on calorimeters, with superior performance to traditional MLI on a per layer basis. Thermal and structural tests were performed with LBMLI supporting an actively cooled shield, and comparisons are made to the performance of traditional MLI and thermal shield supports. LBMLI provided a 51% reduction in heat leak per layer over a previously tested traditional MLI with tank standoffs, a 38% reduction in mass, and was advanced to TRL5. Active thermal control using LBMLI and a broad area cooled shield offers significant advantages in total system heat flux, mass and structural robustness for future Reduced Boil-Off and Zero Boil-Off cryogenic missions with durations over a few weeks.
Orai3 channel is the 2-APB-induced endoplasmic reticulum calcium leak.
Leon-Aparicio, Daniel; Pacheco, Jonathan; Chavez-Reyes, Jesus; Galindo, Jose M; Valdes, Jesus; Vaca, Luis; Guerrero-Hernandez, Agustin
2017-07-01
We have studied in HeLa cells the molecular nature of the 2-APB induced ER Ca 2+ leak using synthetic Ca 2+ indicators that report changes in both the cytoplasmic ([Ca 2+ ] i ) and the luminal ER ([Ca 2+ ] ER ) Ca 2+ concentrations. We have tested the hypothesis that Orai channels participate in the 2-APB-induced ER Ca 2+ leak that was characterized in the companion paper. The expression of the dominant negative Orai1 E106A mutant, which has been reported to block the activity of all three types of Orai channels, inhibited the effect of 2-APB on the [Ca 2+ ] ER but did not decrease the ER Ca 2+ leak after thapsigargin (TG). Orai3 channel, but neither Orai1 nor Orai2, colocalizes with expressed IP 3 R and only Orai3 channel supported the 2-APB-induced ER Ca 2+ leak, while Orai1 and Orai2 inhibited this type of ER Ca 2+ leak. Decreasing the expression of Orai3 inhibited the 2-APB-induced ER Ca 2+ leak but did not modify the ER Ca 2+ leak revealed by inhibition of SERCA pumps with TG. However, reducing the expression of Orai3 channel resulted in larger [Ca 2+ ] i response after TG but only when the ER store had been overloaded with Ca 2+ by eliminating the acidic internal Ca 2+ store with bafilomycin. These data suggest that Orai3 channel does not participate in the TG-revealed ER Ca 2+ leak but forms an ER Ca 2+ leak channel that is limiting the overloading with Ca 2+ of the ER store. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bogni, Serge; Ortner, Maria-Anna; Vajtai, Istvan; Jost, Christian; Reinert, Michael; Dallemagne, Bernard; Frenz, Martin
2012-07-01
Complete closure of gastrotomy is the linchpin of safe natural orifice transgastric endoscopic surgery. To evaluate feasibility and efficacy of a new method of gastrotomy closure by using a sutureless laser tissue-soldering (LTS) technique in an ex vivo porcine stomach. In vitro experiment. Experimental laboratory. Histological analysis and internal and external liquid pressure with and without hydrochloric acid exposure were determined comparing gastrotomy closure with LTS and with hand-sewn surgical sutures. Comparison of LTS and hand-sewn surgical gastrotomy closure. The primary outcome parameter was the internal leak pressure. Secondary parameters were the difference between internal and external leak pressures, the impact of an acid environment on the device, histological changes, and feasibility of endoscopic placement. The internal liquid leak pressure after LTS was almost twice as high as after hand-sewn surgical closure (416 ± 53 mm Hg vs 229 ± 99 mm Hg; P = .01). The internal leak pressure (416 ± 53 mm Hg) after LTS was higher than the external leak pressure (154 ± 46 mm Hg; P < .0001). An acidic environment did not affect leak pressure after LTS. Endoscopic LTS closure was feasible in all experiments. Histopathology revealed only slight alterations beneath the soldering plug. In vitro experiments. Leak pressure after LTS closure of gastrotomy is higher than after hand-sewn surgical closure. LTS is a promising technique for closure of gastrotomies and iatrogenic perforations. Further experiments, in particular survival studies, are mandatory. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Analytical study of the performance of a geomembrane leak detection system.
Lugli, Francesco; Mahler, Claudio Fernando
2016-05-01
The electrical detection of leaks in geomembranes is a method that allows identifying leakage of contaminants in lined facilities (e.g. sanitary landfills, pollutant ponds, etc.). The procedure in the field involves placing electrodes above and below the geomembrane, to generate an electrical current, which in turn engenders an electric potential distribution in the protective layer (generally a clayey soil). The electric potential will be greater in areas with higher current density, i.e. near leaks. In this study, we combined models from the literature to carry out a parametric analysis to identify the variables that most influence the amplitude of the electrical signals produced by leaks. The basic hypothesis is that the electrical conduction phenomena in a liner system could be depicted by a direct current circuit. After determining the value of the current at the leak, we calculated the electric potential distribution according to the model of Darilek and Laine. This enabled analysing the sensitivity of the parameters, which can be useful in the design of landfills and facilitate the location of leaks. This study showed that geomembranes with low electrical resistance (owing to low thickness, low resistivity, or extensive area) can hinder the leak detection process. In contrast, low thickness and high resistivity of the protection layer magnify the leak signal. © The Author(s) 2016.
Schiff, A; Roy, S; Pignot, M; Ghosh, S K; Fegelman, E J
2017-01-01
This targeted chart review study reports the first ever detailed global account of clinical approaches adopted to detect and manage anastomotic leaks identified during surgery in routine clinical practice. 156 surgeons from eight countries retrospectively extracted data from surgical records of 458 patients who underwent colorectal surgery with an identified intraoperative leak at the circular anastomosis. Demographic details, procedures, and outcomes were analyzed descriptively, by country. Most surgeries were performed laparoscopically (57.6%), followed by open surgeries (35.8%). The burden of intraoperative leaks on the healthcare system is driven in large part by the additional interventions such as using a sealant, recreating the anastomosis, and diverting the anastomosis to a colostomy bag, undertaken to manage the leak. The mean duration of hospitalization was 19.9 days. Postoperative anastomotic leaks occurred in 62 patients (13.5%), most frequently 4 to 7 days after surgery. Overall, country-specific differences were observed in patient characteristics, surgical procedures, method of diagnosis of intraoperative leak, interventions, and length of hospital stay. The potential cost of time and material needed to repair intraoperative leaks during surgery is substantial and often hidden to the healthcare system, potentially leading to an underestimation of the impact of this complication.
Development of a 5,000 m(3) super-pressure balloon with a diamond-shaped net
NASA Astrophysics Data System (ADS)
Saito, Yoshitaka; Tanaka, Shigeki; Nakashino, Kyoichi; Matsushima, Kiyoho; Goto, Ken; Furuta, Ryosuke; Domoto, Kodai; Akita, Daisuke; Hashimoto, Hiroyuki
A light super-pressure balloon of which weight will be comparable to the weight of the zero-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m(3) balloon. A flight test of a 3,000 m(3) balloon in the tandem balloon configuration with a 15,000 m(3) zero-pressure balloon was performed in 2012. Although a small gas leak occurred in the super-pressure balloon at the differential pressure of 400 to 500 Pa, the differential pressure reached the highest value of 814 Pa and kept positive through the level flight lasting for 25 minutes due to its slow leakage. To avoid a possible stress concentration to films at the polar area, a new design setting the meridian length of the balloon gore film equal to the length of the net was adopted. A 3-m balloon with the design was developed and its capacity to resist pressure at room temperature and at -30 (°) C was checked through the ground inflation tests. In 2013, a balloon of the same model was launched in the tandem balloon configuration with 2 kg rubber balloons. It was confirmed that the balloon could withstand the maximum differential pressure of 6,280 Pa, could withstand the differential pressure of 5,600 Pa for 2 hours, and there was a small gas leak through a hole with an area of 0.4 mm(2) which was also found in the ground leakage test. These results indicated that the improvement was adequate and there was no problem for the super-pressure balloon to fly in the environment of the stratosphere except for the problem of the small gas leak. In 2014, a flight test of a 5,000 m(3) balloon will be performed. In this paper, after reviewing the method to cover a balloon with a diamond-shaped net, the current status of the development will be reported.
Testing limits to airflow perturbation device (APD) measurements.
Lopresti, Erika R; Johnson, Arthur T; Koh, Frank C; Scott, William H; Jamshidi, Shaya; Silverman, Nischom K
2008-10-31
The Airflow Perturbation Device (APD) is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O.sec/L for control and 3.9 cm H2O.sec/L for the leak). This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O.sec/L, respectively). Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O.sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O.sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O.sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O.sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O.sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD measurement from 4.0 cm H2O.sec/L for the control to 3.6 cm H2O.sec/L for the tube, the difference was not statistically significant. The APD can be adapted for use in ventilated, unconscious, and uncooperative patients with use of a ventilator tube and an oronasal mask without significantly affecting measurements. Adding a resistance in series with the APD mouthpiece has an additive effect on resistance measurements, and can be used for qualitative calibration. A leak size of at least the equivalent of two 3.2 mm diameter tubes can be tolerated without significantly affecting APD measurements.
Vendors unveil one-step fugitive emissions monitoring, management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walter, M.
1995-04-01
An alliance of manufacturers has developed a ``single-source solution`` for fugitive emissions monitoring. The LeakTracker{trademark} system combines barcode scans, and vapor detection and data collection capabilities to help companies comply with leak detection and repair requirements as mandated by the Environmental Protection Agency`s Method 21 guidelines. LeakTracker doubles productivity and helps eliminate human-error factors associated with fugitive emissions monitoring. Two-person teams, clipboard-and-pencil data entry, and manual data transcription are eliminated. By automating the process and integrating all components, a technician can monitor 500 points daily following Method 21 guidelines, compared to about 250 readings per day using other systems. LeakTrackermore » includes a handheld workstation, sampling probe and laser-scan barcode reader that fit in a vest worn by a field technician. The technician points the workstation toward a barcode tag and pulls the trigger, which initiates a barcode read and automatically records the time, date and location. While the detachable probe ``sniffs`` for emissions, an analyzer interface module converts the gas detection signal from analog to digital format, allowing data to be recorded by the workstation. LeakTracker has an accuracy rate of 1 part per million.« less
Schiesser, Marc; Guber, Josef; Wildi, Stefan; Guber, Ivo; Weber, Markus; Muller, Markus K
2011-08-01
In up to 4% of laparoscopic Roux-en-Y gastric bypass (LRYGB) procedures, anastomotic leaks occur. Early detection of gastrointestinal leakage is important for successful treatment. Consequently, many centers advocate routine postoperative upper gastrointestinal (UGI) series. The aim of this study was to determine the utility of this practice after LRYGB. Eight hundred four consecutive patients undergoing LRYGB from June 2000 to April 2010 were analyzed prospectively. The first 382 patients received routine UGI series between the third and fifth postoperative days (group A). Thereafter, the test was only performed when clinical findings (tachycardia, fever, and drainage content) were suspicious for a leak of the gastrointestinal anastomosis (group B; n = 422). Overall, nine of 804 (1.1%) patients suffered from leaks at the gastroenterostomy. In group A, four of 382 (1%) patients had a leak, but only two were detected by the routine UGI series. This corresponds to a sensitivity of 50%. In group B, the sensitivity was higher with 80%. Specificities were comparable with 97% and 91%, respectively. Routine UGI series cost only 1.6% of the overall costs of a non-complicated gastric bypass procedure. With this leak rate and sensitivity, US $86,800 would have to be spent on 200 routine UGI series to find one leak which is not justified. This study shows that routine UGI series have a low sensitivity for the detection of anastomotic leaks after LRYGB. In most cases, the diagnosis is initiated by clinical findings. Therefore, routine upper gastrointestinal series are of limited value for the diagnosis of a leak.
The U.S. Environmental Protection Agency (EPA) sponsored a large-scale field demonstration of innovative leak detection/location and condition assessment technologies on a 76-year old, 2,000-ft long, cement-lined, 24-in. cast iron water main in Louisville, KY from July through Se...
40 CFR 60.505 - Reporting and recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (8) Test results: Actual pressure change in 5 minutes, mm of water (average for 2 runs). (c) A record of each monthly leak inspection required under § 60.502(j) shall be kept on file at the terminal for... of inspection. (2) Findings (may indicate no leaks discovered; or location, nature, and severity of...
46 CFR 12.15-9 - Examination requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... supply of water to boilers, the dangers of high and low water and remedial action X X X 20. Operation..., including testing for leaks, operation of bypasses, and making up of joints X X 8. Safety precautions to be... accumulation of oil in furnaces, bilges, floorplates, and tank tops; flarebacks, leaks in fuel oil heaters...
ACOUSTIC LOCATION OF LEAKS IN PRESSURIZED UNDERGROUND PETROLEUM PIPELINES
Experiments were conducted at the UST Test Apparatus Pipeline in which three acoustic sensors separated by a maximum distance of 38 m (125-ft) were used to monitor signals produced by 3.0-, 1.5-, and 1.0-gal/h leaks in the wall of a 2-in.-diameter pressurized petroleum pipeline. ...
10 CFR 32.59 - Same: Leak testing of each source.
Code of Federal Regulations, 2013 CFR
2013-01-01
... kilobecquerels (0.1 microcurie) of americium-241 or radium-226 before transferring the source to a general... capable of detecting 0.185 kilobecquerel (0.005 microcurie) of americium-241 or radium-226. If a source has been shown to be leaking or losing more than 0.185 kilobecquerel (0.005 microcurie) of americium...
10 CFR 32.59 - Same: Leak testing of each source.
Code of Federal Regulations, 2014 CFR
2014-01-01
... kilobecquerels (0.1 microcurie) of americium-241 or radium-226 before transferring the source to a general... capable of detecting 0.185 kilobecquerel (0.005 microcurie) of americium-241 or radium-226. If a source has been shown to be leaking or losing more than 0.185 kilobecquerel (0.005 microcurie) of americium...
Measuring Leakage From Large, Complicated Machinery
NASA Technical Reports Server (NTRS)
Bottemiller, S.
1987-01-01
Test chamber improvised from large bag. Cumulative sizes of leaks in large, complicated machinery measure with relatively simple variation of helium leak-checking technique. When used to check Space Shuttle main engine, new technique gave repeatable and correct results within 0.5 stdin.3/min (1.4 x 10 negative to the seventh power stdm3/s).
Present-day stress magnitude at depth from leak-off tests in Italy
NASA Astrophysics Data System (ADS)
Mariucci, M. T.; Montone, P.; Pierdominici, S.
2012-04-01
We present new results from the analysis of leak-off tests, performed in deep oil wells in Italy, to characterize the present-day stress magnitude and regime in the crust. In the last years we have collected a large number of data (more than 500) from different stress indicators, mainly borehole breakouts, earthquake focal mechanisms and fault data, which provided information on the present-day stress orientations. In some areas the tectonic regime has been inferred either from fault plane solutions of M≥4 earthquakes or from stress inversions of smaller earthquakes. Where seismicity lacks, the regime is not well constrained and little or no information on the magnitude of the crustal stresses is available. In order to improve our knowledge in stress regime and its magnitude in Italy, in this work we use the leak-off test technique. Each test is performed at the bottom of an open hole by sealing off a section and then slowly pressurizing with a fluid until hydraulic tensile fractures develop. The minimum horizontal stress is inferred by leak-off pressure record, the vertical stress is computed by rock density data and the maximum horizontal stress is estimated applying a specific formula from the literature. Thanks to ENI S.p.A. (Italian oil company), that kindly provided new well data, we have been able to perform a critical review of our preliminary calculations and to enhance our previous results concerning stress magnitudes. Totally, we have analyzed 192 leak-off tests at depth between 200 and 5400m (average 1800m). In particular, wells are located along the Italian peninsula and in Sicily: most of them are in the Po Plain and along the Apenninic foredeep; few are in southern Apenninic belt and a few tens are in Sicily. After an accurate selection of the most robust results, we better characterize the Italian stress regime at depth.
Polymer Matrix Composite Lines and Ducts
NASA Technical Reports Server (NTRS)
Nettles, A. T.
2001-01-01
Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, a task was undertaken to assess the feasibility of making cryogenic feedlines with integral flanges from polymer matrix composite materials. An additional level of complexity was added by having the feedlines be elbow shaped. Four materials, each with a unique manufacturing method, were chosen for this program. Feedlines were to be made by hand layup (HLU) with standard autoclave cure, HLU with electron beam cure, solvent-assisted resin transfer molding (SARTM), and thermoplastic tape laying (TTL). A test matrix of fill and drain cycles with both liquid nitrogen and liquid helium, along with a heat up to 250 F, was planned for each of the feedlines. A pressurization to failure was performed on any feedlines that passed the cryogenic cycling testing. A damage tolerance subtask was also undertaken in this study. The effects of foreign object impact to the materials used was assessed by cross-sectional examination and by permeability after impact testing. At the end of the program, the manufacture of the electron beam-cured feedlines never came to fruition. All of the TTL feedlines leaked heavily before any cryogenic testing, all of the SARTM feedlines leaked heavily after one cryogenic cycle. Thus, only the HLU with autoclave cure feedlines underwent the complete test matrix. They passed the cyclic testing and were pressurized to failure.
Aging Behavior of the EPDM O-Rings in the H1616 Shipping Package
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.; Stefek, T.; Skidmore, E.
The H1616 shipping package is used within the DOE complex for shipping tritium reservoirs. The annual recertification frequency can create logistical difficulties with other constraints on the timing of shipments; thus, a longer re-certification period is desirable. The ethylene propylene diene monomer (EPDM) O-rings used in the H1616 shipping package are being aged and tested at the Savannah River National Laboratory (SRNL) to provide a technical basis for extending the annual maintenance of the H1616 shipping package. H1616 EPDM O-rings are being aged at elevated temperature, and tested for degradation in mechanical properties, compression stress relaxation (CSR) behavior, and leakmore » performance. Mechanical properties of aged O-rings show significant degradation can occur, but an inert atmosphere (argon backfill) greatly reduces the rate of degradation. The CSR behavior of O-rings was evaluated in air at 79 to 177 °C. These collective data were used to develop a predictive model for extrapolation of CSR behavior to relevant service temperatures (<67 °C). O-rings were also aged in H1616 Containment Vessels (CV) in an inert atmosphere at 71 to 149 °C. The vessels are helium leak tested periodically to determine if they continue to remain leak-tight. The vessel tests provide a solid demonstration that the H1616 O-rings will remain leak-tight at temperatures up to 113 °C for up to approximately 2.3 years. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in service. The predictive model developed from the CSR data conservatively indicates a service life of ~5 years at 67 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance. Based on the collective data developed to date, SRNL has recommended that the maintenance interval for the H1616 package be extended from 1 year to 2 years. Future recommendations in support of even longer maintenance intervals are expected, as additional aging data become available.« less
Leppänen, Maija; Wu, Bingbing; Corey, Jonathan; Yermakov, Michael; Grinshpun, Sergey A
2018-05-29
Millions of workers, including firefighters, use respiratory protective device. The key aspect in assuring the intended protection level of a respirator is its fit. However, even if the respirator originally fits well, the faceseal may be breached during its use. Until now, there have been no practically viable, inexpensive means to monitor the performance of a respirator during actual use. A novel Respirator Seal Integrity Monitor (ReSIM) was developed and recently evaluated on manikins by our team. The objective of this study was to evaluate the ReSIM effectiveness on respirator-wearing firefighters exposed to aerosols while performing simulated routine operational activities. Initially, fifteen subjects were recruited for the study. Following a preliminary investigation that resulted in modifications in the ReSIM prototype and testing protocol, a subset of nine firefighters was chosen for a full-scale evaluation. The testing was conducted in a 24.3-m 3 exposure chamber using NaCl as the challenge aerosol. Controlled faceseal leaks were established by opening a solenoid valve for 10, 15 or 20 seconds. Leaks were also established as the tested firefighter slightly repositioned the respirator on his/her face. During the testing, the ReSIM measured particles inside a full-face elastomeric respirator with a 72.7% leak detection sensitivity (probability of correct leak identification) and an 84.2% specificity (probability of correct identification of the intervals which are absent of any leak). After adjusting for false negatives and persistent false positives, sensitivity and specificity increased to 83.6% and 92.2%, respectively. The factors causing minor limitations in leak detection sensitivity and specificity can be attributed to variability among subjects, moisture's effect on the particle sensor, and some in-mask sampling bias. In conclusion, the ReSIM can promptly detect the breach in a respirator faceseal with high sensitivity and specificity. Due to its capability to alert the wearer of possible overexposure to hazardous aerosols, the ReSIM concept has a remarkable potential to be applied in various working environments, where respirators are used.
Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano
2012-10-08
Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.
Juloori, Aditya; Tucker, Susan L; Komaki, Ritsuko; Liao, Zhongxing; Correa, Arlene M; Swisher, Stephen G; Hofstetter, Wayne L; Lin, Steven H
2014-04-01
Postoperative morbidities, such as anastomotic leaks, are common after trimodality therapy (chemoradiation followed by surgery) for esophageal cancer. We investigated for factors associated with an increased incidence of anastomotic leaks. Data from 285 esophageal cancer patients treated from 2000 to 2011 with trimodality therapy were analyzed. Anastomotic location relative to preoperative radiation field was assessed using postoperative computed tomographic imaging. Logistic regression was used to evaluate for factors associated with any or clinically relevant (CR) (≥ grade 2) leaks. Overall anastomotic leak rate was 11% (31 of 285), and CR leak rate was 6% (17 of 285). Multivariable analysis identified body mass index (odds ratio [OR], 1.09; 95% confidence interval [CI], 1.00-1.17; OR, 1.11, 95% CI, 1.01-1.22), three-field surgery (OR, 10.01; 95% CI, 3.83-26.21; OR, 4.83; 95% CI, 1.39-16.71), and within radiation field ("in-field") anastomosis (OR, 5.37; 95% CI, 2.21-13.04; OR, 8.63; 95% CI, 2.90-25.65) as independent predictors of both all grade and CR leaks, respectively. While patients with distal esophageal tumors and Ivor-Lewis surgery had the lowest incidence of all grade (6.5%) and CR leaks (4.2%), most of the leaks were associated with the anastomosis constructed within the field of radiation (in-field: 39% and 30% versus out-of-field: 2.6% and 1.0%, respectively, for total and CR leaks, p less than 0.0001, Fisher's exact test). Esophagogastric anastomosis placed within the preoperative radiation field was a very strong predictor for anastomotic leaks in esophageal cancer patients treated with trimodality therapy, among other factors. Surgical planning should include a critical evaluation of the preoperative radiation fields to ensure proper anastomotic placement after chemoradiation therapy.
Anastomotic leaks: what is the best diagnostic imaging study?
Nicksa, G A; Dring, R V; Johnson, K H; Sardella, W V; Vignati, P V; Cohen, J L
2007-02-01
Postoperative anastomotic leaks are one of the most devastating consequences of colorectal surgery. Diagnostic imaging for upper gastrointestinal anastomotic leaks has been evaluated and reported on extensively. No study has compared the utility and effectiveness of CT scans and water-soluble enemas for the identification of postoperative lower gastrointestinal anastomotic leaks. The present study was designed to evaluate and compare these two common radiographic imaging modalities in detecting lower gastrointestinal anastomotic leaks. A retrospective chart review was performed that identified 36 patients during a seven-year period who underwent reoperative surgery for a lower gastrointestinal anastomotic leak. Patient's imaging studies were classified as positive if extravasation of contrast material was demonstrated. When negative, a study was retrospectively reviewed in an attempt to identify findings suggestive of an anastomotic leak. There were 36 patients identified with a postoperative lower gastrointestinal leak requiring surgical intervention. There were 28 of 36 patients (78 percent) re-explored on the basis of a radiologic study demonstrating an anastomotic leak. A total of 27 CT scans were performed, of which 4 (14.8 percent) were considered positive for an anastomotic leak. On review of the remaining negative CT scans, nine (33.3 percent) were considered descriptive positive with a large amount of fluid or air in the peritoneal cavity but without obvious extravasation of contrast. Eighteen patients were evaluated with a water-soluble enema and 15 (83.3 percent) demonstrated extravasation of contrast material. In the 26 patients with a distal anastomotic leak, 17 water-soluble enemas were performed, with 15 (88 percent) demonstrating a leak. In contrast, only 2 of 17 (12 percent) CT scans were positive in this group of patients (P < 0.001). There were ten patients who initially had a CT scan followed by a water-soluble enema. Of these patients, eight of nine (88 percent) initially had a negative CT scan but were considered to be clinically suspicious of having an anastomotic leak and subsequently had a leak demonstrated on a water-soluble enema. Early intervention in patients who develop an anastomotic leak can be shown to improve the ultimate outcome, especially with respect to mortality. It is usually necessary to obtain objective tests of anastomotic integrity because of the nonspecificity of clinical signs. Our study supported the superiority of water-soluble enema to CT imaging in patients in whom both modalities were used. This difference was most pronounced for distal anastomotic leaks, whereas no radiologic imaging study proved effective in evaluating proximal anastomoses.
Low thermal flux glass-fiber tubing for cryogenic service
NASA Technical Reports Server (NTRS)
Hall, C. A.; Spond, D. E.
1977-01-01
This paper describes analytical techniques, fabrication development, and test results for composite tubing that has many applications in aerospace and commercial cryogenic installations. Metal liner fabrication is discussed in detail with attention given to resistance-welded liners, fusion-welded liners, chem-milled tubing liners, joining tube liners and end fittings, heat treatment and leak checks. Composite overwrapping, a second method of tubing fabrication, is also discussed. Test programs and analytical correlation are considered along with composite tubing advantages such as minimum weight, thermal efficiency and safety and reliability.
Development and Characterization of an Oro-Nasal Inhalation Plethysmography Mask Exposure System
2016-08-30
209.3 ± 97.37 mL/min. Standardized tests were used to characterize the inhalation exposure system. The fractional leak rate was 4.17 x 10-5 min-1...chloride (Sigma-Aldrich Corp., St. Louis, MO) and W9-1, Ultra Trace Elemental Analysis Water , (Fisher Scientific, Pittsburgh, PA) and placed in the...cylindrical plethysmograph, with an internal volume of 34.9 L, was leak tested as previously described (Mokler and White, 1983). Nonhuman primates
Zimmitti, Giuseppe; Vauthey, Jean-Nicolas; Shindoh, Junichi; Tzeng, Ching-Wei D.; Roses, Robert E.; Ribero, Dario; Capussotti, Lorenzo; Giuliante, Felice; Nuzzo, Gennaro; Aloia, Thomas A.
2013-01-01
Objective After hepatectomy, bile leaks remain a major cause of morbidity, cost, and disability. This study was designed to determine if a novel intraoperative Air Leak Test (ALT) would reduce the incidence of post-hepatectomy biliary complications. Study design Rates of postoperative biliary complications were compared between 103 patients who underwent ALT and 120 matched patients operated on before ALT was utilized. All study patients underwent major hepatectomy without bile duct resection at 3 high-volume hepatobiliary centers between 2008 and 2012. ALT was performed by placement of a trans-cystic cholangiogram catheter to inject air into the biliary tree while the upper abdomen was filled with saline and the distal common bile duct was manually occluded. Uncontrolled bile ducts were identified by localization of air bubbles at the transection surface and were directly repaired. Results The 2 groups were similar in diagnosis, chemotherapy use, tumor number and size, resection extent, surgery duration, and blood loss (all p>0.05). Single or multiple uncontrolled bile ducts were intraoperatively detected and repaired in 62.1% of ALT vs. 8.3% of non-ALT patients (p<0.001). This resulted in a lower rate of postoperative bile leaks in ALT (1.9%) vs. non-ALT patients (10.8%, p=0.008). Independent risk factors for postoperative bile leaks included extended hepatectomy (p=0.031), caudate resection (p=0.02), and not performing ALT (p=0.002) [odds ratio (95% Confidence Interval): 3.8 (1.3–11.8), 4.0 (1.1–14.3), and 11.8 (2.4–58.8), respectively]. Conclusion ALT is an easily reproducible test that is highly effective for intraoperative detection and repair of open bile ducts, reducing the rate of postoperative bile leaks. PMID:24246619
Zimmitti, Giuseppe; Vauthey, Jean-Nicolas; Shindoh, Junichi; Tzeng, Ching-Wei D; Roses, Robert E; Ribero, Dario; Capussotti, Lorenzo; Giuliante, Felice; Nuzzo, Gennaro; Aloia, Thomas A
2013-12-01
After hepatectomy, bile leaks remain a major cause of morbidity, cost, and disability. This study was designed to determine if a novel intraoperative air leak test (ALT) would reduce the incidence of post-hepatectomy biliary complications. Rates of postoperative biliary complications were compared among 103 patients who underwent ALT and 120 matched patients operated on before ALT was used. All study patients underwent major hepatectomy without bile duct resection at 3 high-volume hepatobiliary centers between 2008 and 2012. The ALT was performed by placement of a transcystic cholangiogram catheter to inject air into the biliary tree, the upper abdomen was filled with saline, and the distal common bile duct was manually occluded. Uncontrolled bile ducts were identified by localization of air bubbles at the transection surface and were directly repaired. The 2 groups were similar in diagnosis, chemotherapy use, tumor number and size, resection extent, surgery duration, and blood loss (all, p > 0.05). Single or multiple uncontrolled bile ducts were intraoperatively detected and repaired in 62.1% of ALT vs 8.3% of non-ALT patients (p < 0.001). This resulted in a lower rate of postoperative bile leaks in ALT (1.9%) vs non-ALT patients (10.8%; p = 0.008). Independent risk factors for postoperative bile leaks included extended hepatectomy (p = 0.031), caudate resection (p = 0.02), and not performing ALT (p = 0.002) (odds ratio = 3.8; 95% CI, 1.3-11.8; odds ratio = 4.0; 95% CI, 1.1-14.3; and odds ratio = 11.8; 95% CI, 2.4-58.8, respectively). The ALT is an easily reproducible test that is highly effective for intraoperative detection and repair of open bile ducts, reducing the rate of postoperative bile leaks. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Development of Test Protocols for International Space Station Particulate Filters
NASA Technical Reports Server (NTRS)
Vijayakumar, R.; Green, Robert D.; Agui, Juan H.
2015-01-01
Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).
Evaluation of the White Test for the Intraoperative Detection of Bile Leakage
Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad
2012-01-01
We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test. PMID:22547901
Evaluation of the white test for the intraoperative detection of bile leakage.
Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad
2012-01-01
We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.
Use of radiometer to reform and repair an old living house to passive solar one
NASA Astrophysics Data System (ADS)
Okamoto, Yoshizo; Inagaki, Terumi; Suzuki, Takakazu; Kurokawa, Takashi
1994-03-01
Japanese living houses mainly consist of wooden elements in high-temperature and moist conditions. To modify the hot and humid environment, a conventional old house was partially rebuilt and repaired. Especially in the winter season, a diagnostic thermographic test was used to find deteriorated and leaking parts of interior and exterior walls. Macroscopic deteriorated parts were checked again in detail. The deteriorated element was then removed. During the reconstruction process, a new solar heat and air conditioning system using a silica-gel adsorber and underground water was installed to cool and warm up the living room. Thermography tests of this remodeled house show that room temperature is always constant and mild to human beings, especially in the winter. Temperature and heat flow distribution of flowing air in the living room was measured using thermal net and wire methods. Leaking thermal streak flow of the gap was locally visualized by the IR radiometer and a highly sensitive video camera. It was verified that IR thermography is a useful measuring instrument to check thermal defects of a house.
TANK ISSUES: DESIGN AND PLACEMENT OF FLOATING LIQUID MONITORING WELLS
Liquid product monitoring is the predominant method of external leak detection where the water table is within the zone of excavation. his paper discusses the use of liquid product monitors at new and old tank installations for detecting leaks from underground hydrocarbon storage...
LOCATING LEAKS WITH ACOUSTIC TECHNOLOGY
Many water distribution systems in this country are almost 100 years old. About 26 percent of piping in these systems is made of unlined cast iron or steel and is in poor condition. Many methods that locate leaks in these pipes are time-consuming, costly, disruptive to operations...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Kyoung Mo; Jee, Kye Kwang; Pyo, Chang Ryul
The basis of the leak before break (LBB) concept is to demonstrate that piping will leak significantly before a double ended guillotine break (DEGB) occurs. This is demonstrated by quantifying and evaluating the leak process and prescribing safe shutdown of the plant on the basis of the monitored leak rate. The application of LBB for power plant design has reduced plant cost while improving plant integrity. Several evaluations employing LBB analysis on system piping based on DEGB design have been completed. However, the application of LBB on main steam (MS) piping, which is LBB applicable piping, has not been performedmore » due to several uncertainties associated with occurrence of steam hammer and dynamic strain aging (DSA). The objective of this paper is to demonstrate the applicability of the LBB design concept to main steam lines manufactured with SA106 Gr.C carbon steel. Based on the material properties, including fracture toughness and tensile properties obtained from the comprehensive material tests for base and weld metals, a parametric study was performed as described in this paper. The PICEP code was used to determine leak size crack (LSC) and the FLET code was used to perform the stability assessment of MS piping. The effects of material properties obtained from tests were evaluated to determine the LBB applicability for the MS piping. It can be shown from this parametric study that the MS piping has a high possibility of design using LBB analysis.« less
Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks.
Park, Bernard J; Snider, John M; Bates, Nathan R; Cassivi, Stephen D; Jett, G Kimble; Sonett, Joshua R; Toloza, Eric M
2016-12-12
A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. In a multicenter prospective single-arm trial, 112 patients with a median age of 69 years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1 month after surgery for procedure-related and device-related complications and presence of air leak. Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2 days (range 1 - 46 days), and median length of hospitalization was 3 days (range 1 - 20 days). This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. ClinicalTrials.gov: NCT01867658 . Registered 3 May 2013.
NASA Astrophysics Data System (ADS)
Sun, W.; Yan, R. X.; Sun, L. C.; Shao, R. P.
2017-12-01
Ultrasonic signal produced by the gas leak is so week that it is difficult to detect, and easily interfered. So developing the noise-resistant and sound focusing accessory for the ultrasonic leak detector is very important for improving ultrasonic leak detector sensitivity and noise-resistant capability. Based on the theory analysis of the leak ultrasonic signal reverberation and anacampsis, the 5A06 aluminium alloy and nylon were selected as the material of noise-resistant and sound focusing accessory by calculation and compare. Then the circular cone trumpet structure was design as the accessory main structure, and the nylon expansion port, nylon shrinking port and aluminium alloy expansion port structures were manufactured. The different structure characters were shown by the contrasting experiment. The results indicate that the nylon expansion circular cone trumpet structure has better sound focusing performance and it can improve the testing sound pressure amplitude 10 bigger than the detector without the accessory. And the aluminium alloy expansion circular cone trumpet structure has better noise-resistant ability than others. These conclusions are very important for the spacecraft leak detection and it can provide some references for the design of the noise-resistant and sound focusing structure.
Hermetic edge sealing of photovoltaic modules
NASA Astrophysics Data System (ADS)
Nowlan, M. J.
1983-07-01
The feasibility of using an electrostatic bonding (ESB) and ultrasonic welding process to produce hermetic edge seals on terrestrial solar cell modules was investigated. The fabrication sequence is to attach an aluminum foil "gasket' to the perimeter of a glass sheet. A cell circuit is next encapsulated inside the gasket, and its aluminum foil back cover is seam welded ultrasonically to the gasket. An ESB process for sealing aluminum to glass was developed in an ambient air atmosphere, which eliminates the requirement for a vacuum or pressure vessel. An ultrasonic seam welding process was also developed which did not degrade the quality of the ESB seal. Good quality welds with minimal deformation were produced. The effectiveness of the above described sealing techniques was tested by constructing 400 sq cm (8 x 8 s64 sq in) sample modules, and then subjecting them to nondestructive fine and gross leak tests. The gross leak tests identified several different causes of leaks which were then eliminated by modifying the assembly process.
Hermetic edge sealing of photovoltaic modules
NASA Technical Reports Server (NTRS)
Nowlan, M. J.
1983-01-01
The feasibility of using an electrostatic bonding (ESB) and ultrasonic welding process to produce hermetic edge seals on terrestrial solar cell modules was investigated. The fabrication sequence is to attach an aluminum foil "gasket' to the perimeter of a glass sheet. A cell circuit is next encapsulated inside the gasket, and its aluminum foil back cover is seam welded ultrasonically to the gasket. An ESB process for sealing aluminum to glass was developed in an ambient air atmosphere, which eliminates the requirement for a vacuum or pressure vessel. An ultrasonic seam welding process was also developed which did not degrade the quality of the ESB seal. Good quality welds with minimal deformation were produced. The effectiveness of the above described sealing techniques was tested by constructing 400 sq cm (8 x 8 s64 sq in) sample modules, and then subjecting them to nondestructive fine and gross leak tests. The gross leak tests identified several different causes of leaks which were then eliminated by modifying the assembly process.
Brunelli, Alessandro; Salati, Michele; Pompili, Cecilia; Gentili, Paolo; Sabbatini, Armando
2017-11-01
To verify the association between the air leak objectively measured intraoperatively (IAL) using the ventilator and the air leak duration after pulmonary lobectomy. Prospective analysis on 111 patients submitted to pulmonary lobectomy (33 by video-assisted thoracic surgery). After resection, objective assessment of air leak (in milliliter per minute) was performed before closure of the chest by measuring the difference between a fixed inspired and expired volume, using a tidal volume of 8 ml/kg, a respiratory rate of 10 and a positive-end expiratory pressure of 5 cmH2O. A multivariable analysis was performed for identifying factors associated with duration of postoperative air leak. Average IAL was 158 ml/min (range 0-1500 ml/min). The best cut-off (receiver-operating characteristics analysis) associated with air leak longer than 5 days was 500 ml/min. Nine patients had IAL >500 ml/min (8%). They had a longer duration of postoperative air leak compared with those with a lower IAL (mean values, 10.1 days, SD 8.8 vs 1.5 days, SD 4.9 P < 0.001). The following variables remained associated with days of air leak duration after multivariable regression: left side resection (P = 0.018), upper site resection (P = 0.031) and IAL >500 ml/min (P < 0.001). The following equation estimating the days of air leak duration was generated: 1.7 + 2.4 × left side + 2.2 × upper site + 8.8 × IAL >500. The air leak measurement using the ventilator parameters after lung resection may assist in estimating the risk of postoperative prolonged air leak. An IAL > 500 ml/min may warrant the use of intraoperative preventative measures, particularly after video-assisted thoracic surgery lobectomy where a submersion test is often unreliable. © 2017 European Society of Cardiology and European Atherosclerosis Association. All rights reserved. For permissions please email: journals.permissions@oup.com.
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2013 CFR
2013-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2012 CFR
2012-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2011 CFR
2011-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2014 CFR
2014-01-01
... alarm set-point to a higher level if necessary to operate the pool water purification system to clean up... certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from... either by using a radiation monitor on a pool water circulating system or by analysis of a sample of pool...
ACOUSTIC LOCATION OF LEAKS IN PRESSURIZED UNDER- GROUND PETROLEUM PIPELINES
Experiments were conducted at the Underground Storage Tank (UST) Test Apparatus Pipeline in which three acoustic sensors separated by a maximum distance of 38.1 m (125 ft) were used to monitor signals produced by 11.4-, 5.7-, and 3.8-L/h (3.0-, 1.5-, and 1.0-gal/h) leaks in th...
Improved mitigation of fugitive emissions of hazardous air pollutants (HAPs), volatile organic compounds (VOCs), and greenhouse gas (GHG) emissions is an important emerging topic in many industrial sectors. Efficacious leak detection and repair (LDAR) programs of the future yiel...
Crystal growth furnace safety system validation
NASA Technical Reports Server (NTRS)
Mackowski, D. W.; Hartfield, R.; Bhavnani, S. H.; Belcher, V. M.
1994-01-01
The findings are reported regarding the safe operation of the NASA crystal growth furnace (CGF) and potential methods for detecting containment failures of the furnace. The main conclusions are summarized by ampoule leak detection, cartridge leak detection, and detection of hazardous species in the experiment apparatus container (EAC).
Refinery evaluation of optical imaging to locate fugitive emissions.
Robinson, Donald R; Luke-Boone, Ronke; Aggarwal, Vineet; Harris, Buzz; Anderson, Eric; Ranum, David; Kulp, Thomas J; Armstrong, Karla; Sommers, Ricky; McRae, Thomas G; Ritter, Karin; Siegell, Jeffrey H; Van Pelt, Doug; Smylie, Mike
2007-07-01
Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.
Leak location using the pattern of the frequency response diagram in pipelines: a numerical study
NASA Astrophysics Data System (ADS)
Lee, Pedro J.; Vítkovský, John P.; Lambert, Martin F.; Simpson, Angus R.; Liggett, James A.
2005-06-01
This paper presents a method of leak detection in a single pipe where the behaviour of the system frequency response diagram (FRD) is used as an indicator of the pipe integrity. The presence of a leak in a pipe imposes a pattern on the resonance peaks of the FRD that can be used as a clear indication of leakage. Analytical expressions describing the pattern of the resonance peaks are derived. Illustrations of how this pattern can be used to individually locate and size multiple leaks within the system are presented. Practical issues with the technique, such as the procedure for frequency response extraction, the impact of measurement position, noise- and frequency-dependent friction are also discussed.
Alternative working fluids for unitary equipment: A research perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, V.D.
This paper deals with present and planned ORNL activities to characterize alternatives to R-22 for unitary heat pump and air-conditioning applications. Results of small-scale bread-board tests of potential alternatives R-32, R-134a, R-152a and R-143a are discussed. Portions of the AFEAS/DOE global warming impact study dealing with the unitary application are summarized. Methods for leak detection with the new refrigerants are discussed.
FLOW-i ventilator performance in the presence of a circle system leak.
Lucangelo, Umberto; Ajčević, Miloš; Accardo, Agostino; Borelli, Massimo; Peratoner, Alberto; Comuzzi, Lucia; Zin, Walter A
2017-04-01
Recently, the FLOW-i anaesthesia ventilator was developed based on the SERVO-i intensive care ventilator. The aim of this study was to test the FLOW-i's tidal volume delivery in the presence of a leak in the breathing circuit. We ventilated a test lung model in volume-, pressure-, and pressure-regulated volume-controlled modes (VC, PC, and PRVC, respectively) with a FLOW-i. First, the circuit remained airtight and the ventilator was tested with fresh gas flows of 6, 1, and 0.3 L/min in VC, PC, and PRVC modes and facing 4 combinations of different resistive and elastic loads. Second, a fixed leak in the breathing circuit was introduced and the measurements repeated. In the airtight system, FLOW-i maintained tidal volume (VT) and circuit pressure at approximately the set values, independently of respiratory mode, load, or fresh gas flow. In the leaking circuit, set VT = 500 mL, FLOW-i delivered higher VTs in PC (about 460 mL) than in VC and PRVC, where VTs were substantially less than 500 mL. Interestingly, VT did not differ appreciably from 6 to 0.3 L/min of fresh air flow among the 3 ventilatory modes. In the absence of leakage, peak inspiratory pressures were similar, while they were 35-45 % smaller in PRVC and VC than in PC mode in the presence of leaks. In conclusion, FLOW-i maintained VT (down to fresh gas flows of 0.3 L/min) to 90 % of its preset value in PC mode, which was 4-5 times greater than in VC or PRVC modes.
EVALUATION OF THE HIGH VOLUME COLLECTION SYSTEM (HVCS) FOR QUANTIFYING FUGITIVE ORGANIC VAPOR LEAKS
The report discusses a recently developed measurements technique that offers the potential for providing an easy-to-use and cost effective means to directly measure organic vapor leaks. The method, called High Volume Collection System (HVCS), uses a high volume sampling device an...
Respirator fit and protection through determination of air and particle leakage.
Xu, M; Han, D; Hangal, S; Willeke, K
1991-02-01
A laboratory technique for determining the respirator protection factor from a test of fit is described. A dynamic pressure test quantifies the air flow through the leak. Calibration data, stored in a computer, relate the contaminant influx to this air flow, and a similar pressure test determines the flow through the respirator cartridges and, therefore, the dilution characteristics. Contaminant removal characteristics of the cartridges are stored in the computer. The contaminant penetration is calculated from these data on flow and removal efficiency. Through specification of the aerosol size distribution and the method of measurement, protection factors are calculated for specific work environments, work loads and respirator cartridges. The protection factor is shown to be highly dependent on the method of measuring the contaminant and on the cartridges used.