Sample records for leaks

  1. Acoustic leak detection system

    SciTech Connect

    Peacock, M.J.

    1993-08-03

    An acoustic leak detection system is described for determining the location of leaks in storage tanks, comprising: (a) sensor means for detecting a leak signal; (b) data acquisition means for digitizing and storing leak signals meeting preset criterion; and (c) analysis means for analyzing the digitized signals and computing the location of the source of the leak signals.

  2. Chlorofluorocarbon leak detection technology

    SciTech Connect

    Munday, E.B.

    1990-12-01

    There are about 590 large coolant systems located at the Portsmouth Gaseous Diffusion Plant (PORTS) and the Paducah Gaseous Diffusion Plant (PGDP) leaking nearly 800,000 lb of R-114 refrigerant annually (1989 estimate). A program is now under way to reduce the leakage to 325,000 lb/year -- an average loss of 551 lb/year (0.063 lb/h) per coolant system, some of which are as large as 800 ft. This report investigates leak detection technologies that can be used to locate leaks in the coolant systems. Included are descriptions, minimum leak detection rate levels, advantages, disadvantages, and vendor information on the following technologies: bubbling solutions; colorimetric leak testing; dyes; halogen leak detectors (coronea discharge detectors; halide torch detectors, and heated anode detectors); laser imaging; mass spectroscopy; organic vapor analyzers; odorants; pressure decay methods; solid-state electrolytic-cell gas sensors; thermal conductivity leak detectors; and ultrasonic leak detectors.

  3. Burst diaphragm leak detector

    NASA Technical Reports Server (NTRS)

    Pascolla, J. A.

    1969-01-01

    New method replaces flowmeter approach with readily available burst diaphragm leak detector assembly mounted to all drain ports. This allows simultaneous leak detection of all flange seals under operating conditions.

  4. Leak detector uses ultrasonics

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.; Keir, A. R.

    1978-01-01

    Probe located on outer wall of vacuum-jacketed fluid lines detects leaks on inner wall. Probe picks up and amplifies vibrations that occur when gas rushes through leak and converts them to audible signal or CRT display. System is considerably simpler to use than helium leak detectors and allows rapid checks to be made as part of routine maintenance.

  5. Leak detection/verification

    SciTech Connect

    Krhounek, V.; Zdarek, J.; Pecinka, L.

    1997-04-01

    Loss of coolant accident (LOCA) experiments performed as part of a Leak Before Break (LBB) analysis are very briefly summarized. The aim of these experiments was to postulate the leak rates of the coolant. Through-wall cracks were introduced into pipes by fatigue cycling and hydraulically loaded in a test device. Measurements included coolant pressure and temperature, quantity of leaked coolant, displacement of a specimen, and acoustic emission. Small cracks were plugged with particles in the coolant during testing. It is believed that plugging will have no effect in cracks with leak rates above 35 liters per minute. The leak rate safety margin of 10 is sufficient for cracks in which the leak rate is more than 5 liters per minute.

  6. Detecting Methane Leaks

    NASA Technical Reports Server (NTRS)

    Grant, W. B.; Hinkley, E. D.

    1984-01-01

    Remote sensor uses laser radiation backscattered from natural targets. He/Ne Laser System for remote scanning of Methane leaks employs topographic target to scatter light to receiver near laser transmitter. Apparatus powered by 1.5kW generator transported to field sites and pointed at suspected methane leaks. Used for remote detection of natural-gas leaks and locating methane emissions in landfill sites.

  7. Apparatus for detecting leaks

    DOEpatents

    Booth, Eugene T.

    1976-02-24

    A method and apparatus for determining the position of and estimating the size of leaks in an evacuating apparatus comprising the use of a testing gas such as helium or hydrogen flowing around said apparatus whereby the testing gas will be drawn in at the site of any leaks.

  8. Leak detection aid

    DOEpatents

    Steeper, Timothy J.

    1989-01-01

    A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port.

  9. Leak detection aid

    DOEpatents

    Steeper, T.J.

    1989-12-26

    A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port. 2 figs.

  10. Gaseous leak detector

    DOEpatents

    Juravic, Jr., Frank E.

    1988-01-01

    In a short path length mass-spectrometer type of helium leak detector wherein the helium trace gas is ionized, accelerated and deflected onto a particle counter, an arrangement is provided for converting the detector to neon leak detection. The magnetic field of the deflection system is lowered so as to bring the non linear fringe area of the magnetic field across the ion path, thereby increasing the amount of deflection of the heavier neon ions.

  11. Improved gaseous leak detector

    DOEpatents

    Juravic, F.E. Jr.

    1983-10-06

    In a short path length mass-spectrometer type of helium leak detector wherein the helium trace gas is ionized, accelerated and deflected onto a particle counter, an arrangement is provided for converting the detector to neon leak detection. The magnetic field of the deflection system is lowered so as to bring the nonlinear fringe area of the magnetic field across the ion path, thereby increasing the amount of deflection of the heavier neon ions.

  12. Leaks in pipe networks

    USGS Publications Warehouse

    Pudar, Ranko S.; Liggett, James A.

    1992-01-01

    Leak detection in water-distribution systems can be accomplished by solving an inverse problem using measurements of pressure and/or flow. The problem is formulated with equivalent orifice areas of possible leaks as the unknowns. Minimization of the difference between measured and calculated heads produces a solution for the areas. The quality of the result depends on number and location of the measurements. A sensitivity matrix is key to deciding where to make measurements. Both location and magnitude of leaks are sensitive to the quantity and quality of pressure measurements and to how well the pipe friction parameters are known. The overdetermined problem (more measurements than suspected leaks) gives the best results, but some information can be derived from the underdetermined problem. The variance of leak areas, based on the quality of system characteristics and pressure data, indicates the likely accuracy of the results. The method will not substitute for more traditional leak surveys but can serve as a guide and supplement.

  13. Ammonia Leak Locator Study

    NASA Technical Reports Server (NTRS)

    Dodge, Franklin T.; Wuest, Martin P.; Deffenbaugh, Danny M.

    1995-01-01

    The thermal control system of International Space Station Alpha will use liquid ammonia as the heat exchange fluid. It is expected that small leaks (of the order perhaps of one pound of ammonia per day) may develop in the lines transporting the ammonia to the various facilities as well as in the heat exchange equipment. Such leaks must be detected and located before the supply of ammonia becomes critically low. For that reason, NASA-JSC has a program underway to evaluate instruments that can detect and locate ultra-small concentrations of ammonia in a high vacuum environment. To be useful, the instrument must be portable and small enough that an astronaut can easily handle it during extravehicular activity. An additional complication in the design of the instrument is that the environment immediately surrounding ISSA will contain small concentrations of many other gases from venting of onboard experiments as well as from other kinds of leaks. These other vapors include water, cabin air, CO2, CO, argon, N2, and ethylene glycol. Altogether, this local environment might have a pressure of the order of 10(exp -7) to 10(exp -6) torr. Southwest Research Institute (SwRI) was contracted by NASA-JSC to provide support to NASA-JSC and its prime contractors in evaluating ammonia-location instruments and to make a preliminary trade study of the advantages and limitations of potential instruments. The present effort builds upon an earlier SwRI study to evaluate ammonia leak detection instruments [Jolly and Deffenbaugh]. The objectives of the present effort include: (1) Estimate the characteristics of representative ammonia leaks; (2) Evaluate the baseline instrument in the light of the estimated ammonia leak characteristics; (3) Propose alternative instrument concepts; and (4) Conduct a trade study of the proposed alternative concepts and recommend promising instruments. The baseline leak-location instrument selected by NASA-JSC was an ion gauge.

  14. SEALING SIMULATED LEAKS

    SciTech Connect

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  15. Sensitive hydrogen leak detector

    DOEpatents

    Myneni, G.R.

    1999-08-03

    A sensitive hydrogen leak detector system is described which uses passivation of a stainless steel vacuum chamber for low hydrogen outgassing, a high compression ratio vacuum system, a getter operating at 77.5 K and a residual gas analyzer as a quantitative hydrogen sensor. 1 fig.

  16. Sensitive hydrogen leak detector

    DOEpatents

    Myneni, Ganapati Rao

    1999-01-01

    A sensitive hydrogen leak detector system using passivation of a stainless steel vacuum chamber for low hydrogen outgassing, a high compression ratio vacuum system, a getter operating at 77.5 K and a residual gas analyzer as a quantitative hydrogen sensor.

  17. The Leaking-Toilet Challenge

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2008-01-01

    Leaking toilets can cost homeowners big dollars--often before it is even realized. Homeowners do not necessarily hear it leaking. It just does, and when the water bill comes due, it can be a most unpleasant surprise. This article presents a classroom challenge to try to develop leak-detection ideas that would be inexpensive and easily added to…

  18. Natural gas leak mapper

    DOEpatents

    Reichardt, Thomas A.; Luong, Amy Khai; Kulp, Thomas J.; Devdas, Sanjay

    2008-05-20

    A system is described that is suitable for use in determining the location of leaks of gases having a background concentration. The system is a point-wise backscatter absorption gas measurement system that measures absorption and distance to each point of an image. The absorption measurement provides an indication of the total amount of a gas of interest, and the distance provides an estimate of the background concentration of gas. The distance is measured from the time-of-flight of laser pulse that is generated along with the absorption measurement light. The measurements are formated into an image of the presence of gas in excess of the background. Alternatively, an image of the scene is superimosed on the image of the gas to aid in locating leaks. By further modeling excess gas as a plume having a known concentration profile, the present system provides an estimate of the maximum concentration of the gas of interest.

  19. Aspects of leak detection

    SciTech Connect

    Chivers, T.C.

    1997-04-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant.

  20. Variable leak gas source

    DOEpatents

    Henderson, Timothy M.; Wuttke, Gilbert H.

    1977-01-01

    A variable leak gas source and a method for obtaining the same which includes filling a quantity of hollow glass micro-spheres with a gas, storing said quantity in a confined chamber having a controllable outlet, heating said chamber above room temperature, and controlling the temperature of said chamber to control the quantity of gas passing out of said controllable outlet. Individual gas filled spheres may be utilized for calibration purposes by breaking a sphere having a known quantity of a known gas to calibrate a gas detection apparatus.

  1. Leak test fitting

    DOEpatents

    Pickett, P.T.

    A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.

  2. Leak test fitting

    DOEpatents

    Pickett, Patrick T.

    1981-01-01

    A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.

  3. MASS SPECTROMETER LEAK

    DOEpatents

    Shields, W.R.

    1960-10-18

    An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.

  4. Superfluid helium leak sealant study

    NASA Technical Reports Server (NTRS)

    Vorreiter, J. W.

    1981-01-01

    Twenty-one leak specimens were fabricated in the ends of stainless steel and aluminum tubes. Eighteen of these tubes were coated with a copolymer material to seal the leak. The other three specimens were left uncoated and served as control specimens. All 21 tubes were cold shocked in liquid helium 50 times and then the leak rate was measured while the tubes were submerged in superfluid helium at 1.7 K. During the cold shocks two of the coated specimens were mechanically damaged and eliminated from the test program. Of the remaining 16 coated specimens one suffered a total coating failure and resulting high leak rate. Another three of the coated specimens suffered partial coating failures. The leak rates of the uncoated specimens were also measured and reported. The significance of various leak rates is discussed in view of the infrared astronomical satellite (IRAS) Dewar performance.

  5. Mitochondrial proton and electron leaks

    PubMed Central

    Jastroch, Martin; Divakaruni, Ajit S.; Mookerjee, Shona; Treberg, Jason R.; Brand, Martin D.

    2011-01-01

    Mitochondrial proton and electron leak have a major impact on mitochondrial coupling efficiency and production of reactive oxygen species. In the first part of this chapter, we address the molecular nature of the basal and inducible proton leak pathways, and their physiological importance. The basal leak is unregulated, and a major proportion can be attributed to mitochondrial anion carriers, while the proton leak through the lipid bilayer appears to be minor. The basal proton leak is cell-type specific and correlates with metabolic rate. The inducible leak through the adenine nucleotide translocase (ANT) and uncoupling proteins (UCPs) can be activated by fatty acids, superoxide, or peroxidation products. The physiological role of inducible leak through UCP1 in mammalian brown adipose tissue is heat production, whereas the roles of non-mammalian UCP1 and its paralogous proteins, in particular UCP2 and UCP3, are not yet resolved. The second part of the chapter focuses on the electron leak that occurs in the mitochondrial electron transport chain. Exit of electrons prior to the reduction of oxygen to water at cytochrome c oxidase causes the production of superoxide. As the mechanisms of electron leak are crucial to understanding their physiological relevance, we summarize the mechanisms and topology of electron leak from Complex I and III in studies using isolated mitochondria. We also highlight recent progress and challenges of assessing electron leak in the living cell. Finally, we emphasise the importance of proton and electron leak as therapeutic targets in body weight regulation and insulin secretion. PMID:20533900

  6. 40 CFR 63.1005 - Leak repair.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner...

  7. 40 CFR 63.1024 - Leak repair.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reading measured by Method 21 of 40 CFR part 60, appendix A at the time the leak is successfully repaired... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule....

  8. 40 CFR 63.1024 - Leak repair.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reading measured by Method 21 of 40 CFR part 60, appendix A at the time the leak is successfully repaired... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule....

  9. 40 CFR 65.105 - Leak repair.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... leak. (3) Maximum instrument reading measured by Method 21 of appendix A of 40 CFR part 60 at the time... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or...

  10. 40 CFR 63.1005 - Leak repair.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner...

  11. Chemochromic Hydrogen Leak Detectors

    NASA Technical Reports Server (NTRS)

    Roberson, Luke; Captain, Janine; Williams, Martha; Smith, Trent; Tate, LaNetra; Raissi, Ali; Mohajeri, Nahid; Muradov, Nazim; Bokerman, Gary

    2009-01-01

    At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or

  12. Ultrasonic Leak Detection System

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C. (Inventor); Moerk, J. Steven (Inventor)

    1998-01-01

    A system for detecting ultrasonic vibrations. such as those generated by a small leak in a pressurized container. vessel. pipe. or the like. comprises an ultrasonic transducer assembly and a processing circuit for converting transducer signals into an audio frequency range signal. The audio frequency range signal can be used to drive a pair of headphones worn by an operator. A diode rectifier based mixing circuit provides a simple, inexpensive way to mix the transducer signal with a square wave signal generated by an oscillator, and thereby generate the audio frequency signal. The sensitivity of the system is greatly increased through proper selection and matching of the system components. and the use of noise rejection filters and elements. In addition, a parabolic collecting horn is preferably employed which is mounted on the transducer assembly housing. The collecting horn increases sensitivity of the system by amplifying the received signals. and provides directionality which facilitates easier location of an ultrasonic vibration source.

  13. Method for detecting leaks

    SciTech Connect

    Baillie, L.A.; Senese, F.J.

    1988-09-27

    This patent describes a method for determining leaks in a storage tank containing a liquid. The method consists of: locating a float means initially at a depth in the liquid approximately equal to V/sub L//S/sub L/ where V/sub L/ is the volume of the liquid in the tank and S/sub L/ is free surface area of the liquid in the tank; saturating vapor above the liquid in the tank with vapor of the liquid by atomizing so as to fill the vapor above the liquid with small drops of liquid or coating surfaces of the tank above the liquid with a thin layer of the liquid so as to hasten saturation of the vapor above the liquid, so that temperature variation of the liquid in the tank does not change the depth at which the float means floats in the liquid; and determining changes of location of the float means in the tank.

  14. Hermetic Seal Leak Detection Apparatus

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  15. Cerebrospinal fluid leaks following septoplasty.

    PubMed

    Venkatesan, Naren N; Mattox, Douglas E; Del Gaudio, John M

    2014-12-01

    We conducted a retrospective review to identify the characteristics of cerebrospinal fluid (CSF) leak in patients who had undergone septoplasty and in selected patients who had experienced a spontaneous CSF leak. CSF leak is a known but infrequently reported complication of septoplasty; to the best of our knowledge, only 4 cases have been previously published in the literature. A review of our institution's database revealed 3 cases of postseptoplasty CSF leak. We reviewed all the available data to look for any commonalities among these 7 cases. In addition, we reviewed 6 cases of spontaneous CSF leak selected from our database for the same purpose. For all patients, we noted the side of the cribriform plate defect, its size and, for the postseptoplasty cases, the interval between the septoplasty and the leak repair. Overall, we found that leaks were much more common on the right side than on the left. The sizes of the leaks in the 2 postseptoplasty groups were comparable (mean: 14.0 × 6.4 mm). The interval between septoplasty and leak repair ranged from 2.5 to 20 years in our cases and from 3 days to 22 weeks in the previously published cases. All 3 of the postseptoplasty patients in our database presented with clear rhinorrhea. Two of the 3 patients had meningitis; 1 of these 2 also had pneumocephalus. Of the 6 cases of spontaneous CSF leaks, 4 occurred on the right and 2 on the left; the average size of the defect was 5.8 mm in the greatest dimension. The finding that cribriform plate defects after septoplasty were typically right-sided likely reflects the prevalence of left-sided surgical approaches. Also, the fact that the defects were larger in the postseptoplasty cases than in the spontaneous cases is likely attributable to the torque effect toward the thin skull base that occurs when the perpendicular plate is twisted during septoplasty.

  16. Expandable coating cocoon leak detection system

    NASA Technical Reports Server (NTRS)

    Hauser, R. L.; Kochansky, M. C.

    1972-01-01

    Development of system and materials for detecting leaks in cocoon protective coatings are discussed. Method of applying materials for leak determination is presented. Pressurization of system following application of materials will cause formation of bubble if leak exists.

  17. Aerospace Payloads Leak Test Methodology

    NASA Technical Reports Server (NTRS)

    Lvovsky, Oleg; Grayson, Cynthia M.

    2010-01-01

    Pressurized and sealed aerospace payloads can leak on orbit. When dealing with toxic or hazardous materials, requirements for fluid and gas leakage rates have to be properly established, and most importantly, reliably verified using the best Nondestructive Test (NDT) method available. Such verification can be implemented through application of various leak test methods that will be the subject of this paper, with a purpose to show what approach to payload leakage rate requirement verification is taken by the National Aeronautics and Space Administration (NASA). The scope of this paper will be mostly a detailed description of 14 leak test methods recommended.

  18. Analysis of SX farm leak histories -- Historical leak model (HLM)

    SciTech Connect

    Fredenburg, E.A.

    1998-08-20

    This report uses readily available historical information to better define the volume, chemical composition, and Cs-137/Sr-90 amounts for leaks that have occurred in the past for tanks SX-108, SX-109, SX-111, and SX-112. In particular a Historical Leak Model (HLM) is developed that is a month by month reconciliation of tank levels, fill records, and calculated boil-off rates for these tanks. The HLM analysis is an independent leak estimate that reconstructs the tank thermal histories thereby deriving each tank`s evaporative volume loss and by difference, its unaccounted losses as well. The HLM analysis was meant to demonstrate the viability of its approach, not necessarily to establish the HLM leak estimates as being definitive. Past leak estimates for these tanks have invariably resorted to soil wetting arguments but the extent of soil contaminated by each leak has always been highly uncertain. There is also a great deal of uncertainty with the HLM that was not quantified in this report, but will be addressed later. These four tanks (among others) were used from 1956 to 1975 for storage of high-level waste from the Redox process at Hanford. During their operation, tank waste temperatures were often as high as 150 C (300 F), but were more typically around 130 C. The primary tank cooling was by evaporation of tank waste and therefore periodic replacement of lost volume with water was necessary to maintain each tank`s inventory. This active reflux of waste resulted in very substantial turnovers in tank inventory as well as significant structural degradation of these tanks. As a result of the loss of structural integrity, each of these tanks leaked during their active periods of operation. Unfortunately, the large turnover in tank volume associated with their reflux cooling has made a determination of leak volumes very difficult. During much of these tanks operational histories, inventory losses because of evaporative cooling could have effectively masked any volume

  19. Leak detection with expandable coatings

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Developed and evaluated is a system for leak detection that can be easily applied over separable connectors and that expands into a bubble or balloon if a leak is present. This objective is accomplished by using thin films of Parafilm tape wrapped over connectors, which are then overcoated with a special formulation. The low yield strength and the high elongation of the envelope permit bubble formation if leakage occurs. This system is appropriate for welds and other hardware besides separable connectors. The practical limit of this system appears to be for leaks exceeding 0.000001 cc/sec. If this envelope is used to trap gases for mass spectrometer inspection, leaks in the range of ten to the minus 8th power cc/sec. may be detectable.

  20. Modern halogen leak detectors /Review/

    NASA Astrophysics Data System (ADS)

    Evlampiev, A. I.; Karpov, V. I.; Levina, L. E.

    1981-04-01

    The halogen method is one of the basic techniques of leak detection for monitoring airtightness in such objects as refrigeration equipment and aerosol containers. Sensitivity has been improved by heated platinum emitters which stabilize background currents. Methods for protecting the region in which the gas is selected include placing the sensitive element in a new flow gauge and keeping the chamber at a certain distance from the tested surface. Chromatograph separating columns both increase sensitivity and distinguish test materials on a background of extraneous halogen-containing materials. Solid-state platinum diodes have been used as the sensitive elements of halogen leak detectors. Leak detectors based on electron-capture practically eliminate the effect of contamination of the surrounding atmosphere on leak detector sensitivity. A technique of vacuum testing is based on the high affinity of halogen-containing materials for electrons.

  1. Modern halogen leak detectors /Review/

    NASA Astrophysics Data System (ADS)

    Evlampiev, A. I.; Karpov, V. I.; Levina, L. E.

    1980-09-01

    The halogen method is one of the basic techniques of leak detection for monitoring airtightness in such objects as refrigeration equipment and aerosol containers. Sensitivity has been improved by heated platinum emitters which stabilize background currents. Methods for protecting the region in which the gas is selected include placing the sensitive element in a new flow gauge and keeping the chamber at a certain distance from the tested surface. Chromatograph separating columns both increase sensitivity and distinguish test materials on a background of extraneous halogen-containing materials. Solid-state platinum diodes have been used as the sensitive elements of halogen leak detectors. Leak detectors based on electron-capture practically eliminate the effect of contamination of the surrounding atmosphere on leak detector sensitivity. A technique of vacuum testing is based on the high affinity of halogen-containing materials for electrons.

  2. Leak test adapter for containers

    DOEpatents

    Hallett, Brian H.; Hartley, Michael S.

    1996-01-01

    An adapter is provided for facilitating the charging of containers and leak testing penetration areas. The adapter comprises an adapter body and stem which are secured to the container's penetration areas. The container is then pressurized with a tracer gas. Manipulating the adapter stem installs a penetration plug allowing the adapter to be removed and the penetration to be leak tested with a mass spectrometer. Additionally, a method is provided for using the adapter.

  3. Intelligent Leak Detection System

    SciTech Connect

    Mohaghegh, Shahab D.

    2014-10-27

    apability of underground carbon dioxide storage to confine and sustain injected CO2 for a very long time is the main concern for geologic CO2 sequestration. If a leakage from a geological CO2 sequestration site occurs, it is crucial to find the approximate amount and the location of the leak in order to implement proper remediation activity. An overwhelming majority of research and development for storage site monitoring has been concentrated on atmospheric, surface or near surface monitoring of the sequestered CO2. This study aims to monitor the integrity of CO2 storage at the reservoir level. This work proposes developing in-situ CO2 Monitoring and Verification technology based on the implementation of Permanent Down-hole Gauges (PDG) or “Smart Wells” along with Artificial Intelligence and Data Mining (AI&DM). The technology attempts to identify the characteristics of the CO2 leakage by de-convolving the pressure signals collected from Permanent Down-hole Gauges (PDG). Citronelle field, a saline aquifer reservoir, located in the U.S. was considered for this study. A reservoir simulation model for CO2 sequestration in the Citronelle field was developed and history matched. The presence of the PDGs were considered in the reservoir model at the injection well and an observation well. High frequency pressure data from sensors were collected based on different synthetic CO2 leakage scenarios in the model. Due to complexity of the pressure signal behaviors, a Machine Learning-based technology was introduced to build an Intelligent Leakage Detection System (ILDS). The ILDS was able to detect leakage characteristics in a short period of time (less than a day) demonstrating the capability of the system in quantifying leakage characteristics subject to complex rate behaviors. The performance of ILDS was examined under different conditions such as multiple well leakages, cap rock leakage, availability of an additional monitoring well, presence of pressure drift and noise

  4. Intelligent Leak Detection System

    2014-10-27

    apability of underground carbon dioxide storage to confine and sustain injected CO2 for a very long time is the main concern for geologic CO2 sequestration. If a leakage from a geological CO2 sequestration site occurs, it is crucial to find the approximate amount and the location of the leak in order to implement proper remediation activity. An overwhelming majority of research and development for storage site monitoring has been concentrated on atmospheric, surface or nearmore » surface monitoring of the sequestered CO2. This study aims to monitor the integrity of CO2 storage at the reservoir level. This work proposes developing in-situ CO2 Monitoring and Verification technology based on the implementation of Permanent Down-hole Gauges (PDG) or “Smart Wells” along with Artificial Intelligence and Data Mining (AI&DM). The technology attempts to identify the characteristics of the CO2 leakage by de-convolving the pressure signals collected from Permanent Down-hole Gauges (PDG). Citronelle field, a saline aquifer reservoir, located in the U.S. was considered for this study. A reservoir simulation model for CO2 sequestration in the Citronelle field was developed and history matched. The presence of the PDGs were considered in the reservoir model at the injection well and an observation well. High frequency pressure data from sensors were collected based on different synthetic CO2 leakage scenarios in the model. Due to complexity of the pressure signal behaviors, a Machine Learning-based technology was introduced to build an Intelligent Leakage Detection System (ILDS). The ILDS was able to detect leakage characteristics in a short period of time (less than a day) demonstrating the capability of the system in quantifying leakage characteristics subject to complex rate behaviors. The performance of ILDS was examined under different conditions such as multiple well leakages, cap rock leakage, availability of an additional monitoring well, presence of pressure drift

  5. Leak detection on petroleum pipelines

    SciTech Connect

    Poynter, W.G.

    1995-12-01

    Accident statitics clearly show that pipelines are the safest method for transporting hydrocarbon fluids compared to trucking, rail or marine transportation. Even so, leaks and spills do occasionally happen and can be (1) very costly in terms of product loss and clean up, and (2) hazardous to life, property and the environment. The pipeline industry recognizes its responsibility to be proactive in technological advancements which promote public safety, and many pipeline operators either already have or are planning to install real-time methods for determining when leak occur. The intent is to detect leaks as soon as possible to permit the operator to shut down a pipeline and minimize the amount of stock loss and potential hazard to the public. Some federal and state regulations require some form of leak detection on pipelines which transport hazardous fluids through populated and otherwise sensitive areas. There are three basic methods for monitoring pipeline systems for leaks: (1) EXS (external sensors) which use acoustical devices or hydrocarbon sensors which may be buried with the pipe or placed at critical above ground locations along the path of the pipeline; (2) VIVO (volume in/volume out) which relies on volumetric measurement and comparison of everything which enters a pipeline system with everything that leaves the system; and (3) PPA (Pressure Point Analysis) is a dynamic method for monitoring the energy balance on a pipeline as represented by pressure and velocity readings at various points in the pipeline system. These systems are discussed.

  6. Mitigated Transfer Line Leaks that Result in Surface Pools and Spray Leaks into Pits

    SciTech Connect

    HEY, B.E.

    1999-12-07

    This analysis provides radiological and toxicological consequence calculations for postulated mitigated leaks during transfers of six waste compositions. Leaks in Cleanout Boxes equipped with supplemental covers and leaks in pits are analyzed.

  7. Mapping urban pipeline leaks: methane leaks across Boston.

    PubMed

    Phillips, Nathan G; Ackley, Robert; Crosson, Eric R; Down, Adrian; Hutyra, Lucy R; Brondfield, Max; Karr, Jonathan D; Zhao, Kaiguang; Jackson, Robert B

    2013-02-01

    Natural gas is the largest source of anthropogenic emissions of methane (CH(4)) in the United States. To assess pipeline emissions across a major city, we mapped CH(4) leaks across all 785 road miles in the city of Boston using a cavity-ring-down mobile CH(4) analyzer. We identified 3356 CH(4) leaks with concentrations exceeding up to 15 times the global background level. Separately, we measured δ(13)CH(4) isotopic signatures from a subset of these leaks. The δ(13)CH(4) signatures (mean = -42.8‰ ± 1.3‰ s.e.; n = 32) strongly indicate a fossil fuel source rather than a biogenic source for most of the leaks; natural gas sampled across the city had average δ(13)CH(4) values of -36.8‰ (± 0.7‰ s.e., n = 10), whereas CH(4) collected from landfill sites, wetlands, and sewer systems had δ(13)CH(4) signatures ~20‰ lighter (μ = -57.8‰, ± 1.6‰ s.e., n = 8). Repairing leaky natural gas distribution systems will reduce greenhouse gas emissions, increase consumer health and safety, and save money.

  8. Leak prevention critical for ASTs

    SciTech Connect

    Edwards, B.

    1994-08-01

    Aboveground storage tanks can be crafted to prevent leaks caused by vandalism, overfill accidents and faulty valves. New designs and safety devices available in aboveground storage tanks (ASTs) have made ASTs viable option for owners of commercial, institutional and governmental facilities with storage needs of less than 20,000 gallons.

  9. Optical Detection Of Cryogenic Leaks

    NASA Technical Reports Server (NTRS)

    Wyett, Lynn M.

    1988-01-01

    Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

  10. Pipe Leak Detection Technology Development

    EPA Science Inventory

    The U. S. Environmental Protection Agency (EPA) has determined that one of the nation’s biggest infrastructural needs is the replacement or rehabilitation of the water distribution and transmission systems. The institution of more effective pipe leak detection technology will im...

  11. Variable gas leak rate valve

    DOEpatents

    Eernisse, Errol P.; Peterson, Gary D.

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  12. LOCATING LEAKS WITH ACOUSTIC TECHNOLOGY

    EPA Science Inventory

    Many water distribution systems in this country are almost 100 years old. About 26 percent of piping in these systems is made of unlined cast iron or steel and is in poor condition. Many methods that locate leaks in these pipes are time-consuming, costly, disruptive to operations...

  13. Rapid leak detection with liquid crystals

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.; Ruppe, E. P.

    1978-01-01

    Small leaks in vacuum lines are detected by applying liquid-crystal coating, warming suspected area, and observing color change due to differential cooling by leak jet. Technique is used on inside or outside walls of vacuum-jacketed lines.

  14. Presidential Leaks: Rhetoric and Mediated Political Knowledge.

    ERIC Educational Resources Information Center

    Erickson, Keith V.

    1989-01-01

    Argues that presidential leaks constitute rhetorical acts, enabling administrations to exercise a variety of rhetorically potent options not afforded by the public forum. Proposes a typology of presidential leaks and analyzes their rhetorical functions, benefits, and liabilities. (MM)

  15. Anaerobic polymers as high vacuum leak sealants

    NASA Technical Reports Server (NTRS)

    Kendall, B. R. F.

    1982-01-01

    Anaerobic polymers are useful as solventless leak sealants with good vacuum properties at moderate temperatures. Loctite 290 can seal leaks in a range generally encountered in carefully constructed ultrahigh vacuum and high vacuum systems. It was found that small leaks are sealed best under vacuum, whereas large leaks should be sealed at atmospheric pressure. The high-temperature behavior of Loctite 290 is limited by its fast cure, which prevents deep penetration into small leaks; cracking eventually occurs at the entrance to the leak. Repeated thermal cycling to about 300 C is possible, however, provided viscosity, curing time, and leak size are properly matched to ensure penetration into the body of the leak. This may require special formulations for high temperature vacuum applications.

  16. Stochastic Consequence Analysis for Waste Leaks

    SciTech Connect

    HEY, B.E.

    2000-05-31

    This analysis evaluates the radiological consequences of potential Hanford Tank Farm waste transfer leaks. These include ex-tank leaks into structures, underneath the soil, and exposed to the atmosphere. It also includes potential misroutes, tank overflow

  17. Detecting Leaks With An Infrared Camera

    NASA Technical Reports Server (NTRS)

    Easter, Barry P.; Steffins, Alfred P., Jr.

    1994-01-01

    Proposed test reveals small leak in gas pipe - for example, leak through fatigue crack induced by vibration - even though insulation covers pipe. Infrared-sensitive video camera aimed at part(s) containing suspected leak(s). Insulated pipe pressurized with gas that absorbs infrared light. If crack were present, escaping gas travels along outside of pipe until it reached edge of insulation. Gas emerging from edge of insulation appears as dark cloud in video image.

  18. Sensitivities of Soap Solutions in Leak Detection

    NASA Technical Reports Server (NTRS)

    Stuck, D.; Lam, D. Q.; Daniels, C.

    1985-01-01

    Document describes method for determining minimum leak rate to which soap-solution leak detectors sensitive. Bubbles formed at smaller leak rates than previously assumed. In addition to presenting test results, document discusses effects of joint-flange configurations, properties of soap solutions, and correlation of test results with earlier data.

  19. Leaking electricity in domestic appliances

    SciTech Connect

    Meier, Alan; Rosen, Karen

    1999-05-01

    Many types of home electronic equipment draw electric power when switched off or not performing their principal functions. Standby power use (or ''leaking electricity'') for most appliances ranges from 1 - 20 watts. Even though standby use of each device is small, the combined standby power use of all appliances in a home can easily exceed 50 watts. Leaking electricity is already responsible for 5 to 10 percent of residential electricity use in the United States and over 10 percent in Japan. An increasing number of white goods also have standby power requirements. There is a growing international effort to limit standby power to around one watt per device. New and existing technologies are available to meet this target at little or no extra cost.

  20. Russian Arctic battles pipeline leak

    SciTech Connect

    Stone, R.

    1995-05-12

    An estimated 100,000 barrels of oil have leaked from a corroded pipeline in northern Russia`s Komi Republic since last August. The oil threatens salmon fisheries and marshlands used for grazing cattle and raindeer. This article discusses the spill in relation to other large spills and the possible ecological damage. Russian authorities, first reluctant to come to grips with the spill, are changing their attitudes, a position essential to gaining access to threatened regions for important monitoring studies.

  1. Hydrogen Leak Detection Sensor Database

    NASA Technical Reports Server (NTRS)

    Baker, Barton D.

    2010-01-01

    This slide presentation reviews the characteristics of the Hydrogen Sensor database. The database is the result of NASA's continuing interest in and improvement of its ability to detect and assess gas leaks in space applications. The database specifics and a snapshot of an entry in the database are reviewed. Attempts were made to determine the applicability of each of the 65 sensors for ground and/or vehicle use.

  2. Comprehensive quantitative analysis on privacy leak behavior.

    PubMed

    Fan, Lejun; Wang, Yuanzhuo; Jin, Xiaolong; Li, Jingyuan; Cheng, Xueqi; Jin, Shuyuan

    2013-01-01

    Privacy information is prone to be leaked by illegal software providers with various motivations. Privacy leak behavior has thus become an important research issue of cyber security. However, existing approaches can only qualitatively analyze privacy leak behavior of software applications. No quantitative approach, to the best of our knowledge, has been developed in the open literature. To fill this gap, in this paper we propose for the first time four quantitative metrics, namely, possibility, severity, crypticity, and manipulability, for privacy leak behavior analysis based on Privacy Petri Net (PPN). In order to compare the privacy leak behavior among different software, we further propose a comprehensive metric, namely, overall leak degree, based on these four metrics. Finally, we validate the effectiveness of the proposed approach using real-world software applications. The experimental results demonstrate that our approach can quantitatively analyze the privacy leak behaviors of various software types and reveal their characteristics from different aspects. PMID:24066046

  3. Comprehensive Quantitative Analysis on Privacy Leak Behavior

    PubMed Central

    Fan, Lejun; Wang, Yuanzhuo; Jin, Xiaolong; Li, Jingyuan; Cheng, Xueqi; Jin, Shuyuan

    2013-01-01

    Privacy information is prone to be leaked by illegal software providers with various motivations. Privacy leak behavior has thus become an important research issue of cyber security. However, existing approaches can only qualitatively analyze privacy leak behavior of software applications. No quantitative approach, to the best of our knowledge, has been developed in the open literature. To fill this gap, in this paper we propose for the first time four quantitative metrics, namely, possibility, severity, crypticity, and manipulability, for privacy leak behavior analysis based on Privacy Petri Net (PPN). In order to compare the privacy leak behavior among different software, we further propose a comprehensive metric, namely, overall leak degree, based on these four metrics. Finally, we validate the effectiveness of the proposed approach using real-world software applications. The experimental results demonstrate that our approach can quantitatively analyze the privacy leak behaviors of various software types and reveal their characteristics from different aspects. PMID:24066046

  4. Schlieren optics for leak detection

    NASA Technical Reports Server (NTRS)

    Peale, Robert E.; Ruffin, Alranzo B.

    1995-01-01

    The purpose of this research was to develop an optical method of leak detection. Various modifications of schlieren optics were explored with initial emphasis on leak detection of the plumbing within the orbital maneuvering system of the space shuttle (OMS pod). The schlieren scheme envisioned for OMS pod leak detection was that of a high contrast pattern on flexible reflecting material imaged onto a negative of the same pattern. We find that the OMS pod geometry constrains the characteristic length scale of the pattern to the order of 0.001 inch. Our experiments suggest that optical modulation transfer efficiency will be very low for such patterns, which will limit the sensitivity of the technique. Optical elements which allow a negative of the scene to be reversibly recorded using light from the scene itself were explored for their potential in adaptive single-ended schlieren systems. Elements studied include photochromic glass, bacteriorhodopsin, and a transmissive liquid crystal display. The dynamics of writing and reading patterns were studied using intensity profiles from recorded images. Schlieren detection of index gradients in air was demonstrated.

  5. Management of pancreatic ductal leaks and fistulae.

    PubMed

    Larsen, Michael; Kozarek, Richard

    2014-01-01

    Pancreatic duct leaks can occur as a result of both acute and chronic pancreatitis or in the setting of pancreatic trauma. Manifestations of leaks include pseudocysts, pancreatic ascites, high amylase pleural effusions, disconnected duct syndrome, and internal and external pancreatic fistulas. Patient presentations are highly variable and range from asymptomatic pancreatic cysts to patients with severe abdominal pain and sepsis from infected fluid collections. The diagnosis can often be made by high-quality cross-sectional imaging or during endoscopic retrograde cholangiopancreatography (ERCP). Because of their complexity, pancreatic leak patients are best managed by a multidisciplinary team comprised of therapeutic endoscopists, interventional radiologists, and surgeons in the field of pancreatic interventions. Minor leaks will often resolve with conservative management while severe leaks will frequently require interventions. Endoscopic treatments for pancreatic duct leaks have replaced surgical interventions in many situations. Interventional radiologists also have the ability to offer therapeutic interventions for many leak patients. The mainstay of endotherapy for pancreatic leaks is transpapillary pancreatic duct stenting with a stent that bridges the leak if possible, but varies based on the manifestation and clinical presentation. Fluid collections that result from leaks, such as pseudocysts, can often be treated by endoscopic transluminal drainage with or without endoscopic ultrasound or by percutaneous drainage. Endoscopic interventions have been shown to be effective and have an acceptable complication rate.

  6. Vacuum leak detector and method

    DOEpatents

    Edwards, Jr., David

    1983-01-01

    Apparatus and method for detecting leakage in a vacuum system involves a moisture trap chamber connected to the vacuum system and to a pressure gauge. Moisture in the trap chamber is captured by freezing or by a moisture adsorbent to reduce the residual water vapor pressure therein to a negligible amount. The pressure gauge is then read to determine whether the vacuum system is leaky. By directing a stream of carbon dioxide or helium at potentially leaky parts of the vacuum system, the apparatus can be used with supplemental means to locate leaks.

  7. Leaking mycotic abdominal aortic aneurysm.

    PubMed

    Sing, T M; Young, N; O'Rourke, I C; Tomlinson, P

    1994-11-01

    A case of leaking mycotic abdominal aortic aneurysm is reported, with a brief review of the literature. A 58 year old female presented with shoulder and abdominal pain associated with diarrhoea, vomiting and fever with leucocytosis. Computed tomography of the abdomen showed pooling of contrast in the retroperitoneum anterior to a non-dilated abdominal aorta. There was considerable retroperitoneal blood accumulating in a mass-like lesion in the right lower abdomen and pelvis obstructing the right renal collecting system. Laparotomy revealed a 4 cm diameter saccular aneurysm of the abdominal aorta, with a 1 cm diameter neck. Culture of the thrombus grew Streptococcus pyogenes. PMID:7993259

  8. Leak detection capability in CANDU reactors

    SciTech Connect

    Azer, N.; Barber, D.H.; Boucher, P.J.

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  9. Long-life leak standard assembly

    DOEpatents

    Basford, James A.; Mathis, John E.; Wright, Harlan C.

    1982-01-01

    The present invention is directed to a portable leak standard assembly which is capable of providing a stream of high-purity reference gas at a virtually constant flow rate over an extensive period of time. The leak assembly comprises a high pressure reservoir coupled to a metal leak valve through a valve-controlled conduit. A reproducible leak valve useful in this assembly is provided by a metal tube crimped with a selected pressure loading for forming an orifice in the tube with this orifice being of a sufficient size to provide the selected flow rate. The leak valve assembly is formed of metal so that it can be "baked-out" in a vacuum furnace to rid the reservoir and attendent components of volatile impurities which reduce the efficiency of the leak standard.

  10. Leak detection using structure-borne noise

    NASA Technical Reports Server (NTRS)

    Holland, Stephen D. (Inventor); Chimenti, Dale E. (Inventor); Roberts, Ronald A. (Inventor)

    2010-01-01

    A method for detection and location of air leaks in a pressure vessel, such as a spacecraft, includes sensing structure-borne ultrasound waveforms associated with turbulence caused by a leak from a plurality of sensors and cross correlating the waveforms to determine existence and location of the leak. Different configurations of sensors and corresponding methods can be used. An apparatus for performing the methods is also provided.

  11. Canadian pipeline installs leak-detection system

    SciTech Connect

    Yoon, M.S.; Mensik, M.; Luk, W.Y.

    1988-05-30

    Site-acceptance tests for a recently installed leak-detection system on a pipeline in southern Alberta indicated that the system will reduce spillage because of leaks. The tests on the Porcupine Hills Pipeline also indicated that pipeline isolation and spill containment are enhanced by the use of the system. Covered here are the selection, design, and implementation of the real time leak-detection system and its extension to offshore and arctic applications.

  12. High sensitivity leak detection method and apparatus

    DOEpatents

    Myneni, Ganapatic R.

    1994-01-01

    An improved leak detection method is provided that utilizes the cyclic adsorption and desorption of accumulated helium on a non-porous metallic surface. The method provides reliable leak detection at superfluid helium temperatures. The zero drift that is associated with residual gas analyzers in common leak detectors is virtually eliminated by utilizing a time integration technique. The sensitivity of the apparatus of this disclosure is capable of detecting leaks as small as 1.times.10.sup.-18 atm cc sec.sup.-1.

  13. High sensitivity leak detection method and apparatus

    DOEpatents

    Myneni, G.R.

    1994-09-06

    An improved leak detection method is provided that utilizes the cyclic adsorption and desorption of accumulated helium on a non-porous metallic surface. The method provides reliable leak detection at superfluid helium temperatures. The zero drift that is associated with residual gas analyzers in common leak detectors is virtually eliminated by utilizing a time integration technique. The sensitivity of the apparatus of this disclosure is capable of detecting leaks as small as 1 [times] 10[sup [minus]18] atm cc sec[sup [minus]1]. 2 figs.

  14. Leak detection inside a vacuum vessel

    SciTech Connect

    Obara, K.; Abe, T.; Itou, Y.; Iwama, J.

    1981-01-01

    A facility for leak detection inside a vacuum vessel is developed. It will take the place of conventional helium leak detection method. The facility consists of several devices; a unidirectional detector (a sensor), a vacuum tight manipulator, a simulated defect, a vacuum vessel with a turbomolecular pump system and others. Leak detection experiment on the facility was performed and the position of 3.0*10/sup -///6Torr/BULLET/1/sec helium leak was detected on condition that the sensor was at a distance of 18mm from the defect, and the pressure in the vacuum vessel was 5.0*10/sup -8/Torr.

  15. Endotherapy of leaks and fistula

    PubMed Central

    Goenka, Mahesh Kumar; Goenka, Usha

    2015-01-01

    Perforations, leaks and fistula involving gastrointestinal (GI) tract are increasing encountered in clinical practice. There is a changing paradigm for their management with surgical approach being replaced by conservative approach including endoscopic therapy. Clips (through the scope and over the scope) and covered stent are front runners for endotherapy for GI leaks and fistula. Over the scope clips introduced recently, can treat larger defects compared to through the scope clips. Covered stents are suited for larger defects and those associated with luminal narrowing. However cervical esophagus, gastro-esophageal junction, stomach and right colonic lesions may be better for clip therapy rather than stenting. Recent developments in this field include use of endovac therapy which consists of a sponge with suction device, biodegradable stent, use of fibrin glue and some endo-suturing device. Conservative therapy with no surgical or endoscopic intervention, may be suitable for a small subset of patients. An algorithm based on location, size of defect, associated stricture, infection and available expertise needs to be developed to reduce the mortality and morbidity of this difficult clinical problem. PMID:26140097

  16. Safety upgrades plug car leaks

    SciTech Connect

    Not Available

    1993-08-01

    To lessen the chance of a chemical leak occurring during rail transport, some companies are improving tank car sturdiness and safety by adding such features as top-loading valves, on-board monitoring devices, and thicker, more impact-resistant hulls. Results include a dramatic drop in the number of rail incidents and leak tank cars. Chemicals Division of Olin Corporation (Stamford, Connecticut) has assigned its name to a new fleet of chlorine, caustic soda and toluene diisocyanate (TDI) tank cars. Each car carries the company's Care[trademark]Car registered trademark. The upgrade is part of a company-wide quality improvement process started in 1986. The company requires acoustic emissions (AE) testing on all hazardous materials tank cars. If an area has a defect, it expands and makes a slight sound when subjected to stress. In an AE test, cars are subject to simulated bumps and jolts as in rail shipment. Electronic sensors transfer any stress noises onto a computer screen, where an operator can pinpoint the trouble source.

  17. Sealing leaks in geomembrane liners using electrophoresis

    SciTech Connect

    Darilek, G.T.; Corapcioglu, M.Y.; Yeung, A.T.

    1996-06-01

    An innovative method was demonstrated to seal leaks in geomembrane liners by attracting clay particles to the leaks using electrophoresis. Electrophoresis is the movement of electrically charged particles suspended in a liquid by the action of an electric field. A direct-current voltage impressed across the liner causes electrical current to flow through the leaks. The current produces a strong electric field at leaks. When a clay slurry is dispersed into the liquid in the impoundment, electrophoresis attracts the clay particles to the leaks, thereby sealing them. The method can seal leaks in liquid impoundments without removing the liquid or locating or accessing the leaks. The laboratory and full-scale test results were remarkable in that electrophoresis sealed the leaks completely when a layer of geofabric was under the liner, and electrophoresis reduced the leakage rate through holes as large as 10 mm in diameter by a factor of 1,600 in the field test with gravel under the liner, and by a factor of 1,667 in the laboratory basin with geonet under the liner.

  18. Fighting the Epidemic of Nuclear Plant Leaks.

    ERIC Educational Resources Information Center

    Udell, Richard A.

    1983-01-01

    The current epidemic of steam generator tube leaks alone should put to rest the rosy future once envisioned for nuclear power. It is impossible to regulate quality into a nuclear plant; it must be built and designed that way. The economic impact of the leaks is discussed. (RM)

  19. Distributed fiber optic fuel leak detection system

    NASA Astrophysics Data System (ADS)

    Mendoza, Edgar; Kempen, C.; Esterkin, Yan; Sun, Sunjian

    2013-05-01

    With the increase worldwide demand for hydrocarbon fuels and the vast development of new fuel production and delivery infrastructure installations around the world, there is a growing need for reliable fuel leak detection technologies to provide safety and reduce environmental risks. Hydrocarbon leaks (gas or liquid) pose an extreme danger and need to be detected very quickly to avoid potential disasters. Gas leaks have the greatest potential for causing damage due to the explosion risk from the dispersion of gas clouds. This paper describes progress towards the development of a fast response, high sensitivity, distributed fiber optic fuel leak detection (HySensTM) system based on the use of an optical fiber that uses a hydrocarbon sensitive fluorescent coating to detect the presence of fuel leaks present in close proximity along the length of the sensor fiber. The HySenseTM system operates in two modes, leak detection and leak localization, and will trigger an alarm within seconds of exposure contact. The fast and accurate response of the sensor provides reliable fluid leak detection for pipelines, tanks, airports, pumps, and valves to detect and minimize any potential catastrophic damage.

  20. Distributed fiber optic fuel leak detection system

    NASA Astrophysics Data System (ADS)

    Mendoza, Edgar; Kempen, C.; Esterkin, Yan; Sun, Sonjian

    2013-05-01

    With the increase worldwide demand for hydrocarbon fuels and the vast development of new fuel production and delivery infrastructure installations around the world, there is a growing need for reliable fuel leak detection technologies to provide safety and reduce environmental risks. Hydrocarbon leaks (gas or liquid) pose an extreme danger and need to be detected very quickly to avoid potential disasters. Gas leaks have the greatest potential for causing damage due to the explosion risk from the dispersion of gas clouds. This paper describes progress towards the development of a fast response, high sensitivity, distributed fiber optic fuel leak detection (HySenseTM) system based on the use of an optical fiber that uses a hydrocarbon sensitive fluorescent coating to detect the presence of fuel leaks present in close proximity along the length of the sensor fiber. The HySenseTM system operates in two modes, leak detection and leak localization, and will trigger an alarm within seconds of exposure contact. The fast and accurate response of the sensor provides reliable fluid leak detection for pipelines, tanks, airports, pumps, and valves to detect and minimize any potential catastrophic damage.

  1. Leak checker data logging system

    SciTech Connect

    Payne, J.J.; Gannon, J.C.

    1994-12-31

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time.

  2. Leak checker data logging system

    DOEpatents

    Gannon, J.C.; Payne, J.J.

    1996-09-03

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time. 18 figs.

  3. Leak checker data logging system

    DOEpatents

    Gannon, Jeffrey C.; Payne, John J.

    1996-01-01

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time.

  4. Microwave radar detection of gas pipeline leaks.

    SciTech Connect

    Gopalsami, N.; Kanareykin, D. B.; Asanov, V. D; Bakhtiari, S.; Raptis, A. C.

    2002-10-02

    We are developing a microwave radar sensing and imaging system to detect and locate gas leaks in natural gas pipelines. The underlying detection principle is radar backscattering from the index-of-refraction inhomogeneities introduced by the dispersion of methane in air. An essential first step in the development effort is modeling to estimate the radar cross section. This paper describes the modeling results and the experimental efforts underway to validate the model. For the case of leaks from small holes in a pressurized gas pipeline, we modeled the gas dynamics of the leak jet to determine the plume geometry and the variation of methane concentration in air as a function of distance from the leak source. From the static and dynamic changes in the index of refraction in the turbulent plume, the radar backscatter cross sections were calculated. The results show that the radar cross sections of the leak plumes should be detectable by special-purpose radars.

  5. Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

    NASA Technical Reports Server (NTRS)

    2013-01-01

    In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

  6. Blind Leak Detection for Closed Systems

    NASA Technical Reports Server (NTRS)

    Oelgoetz, Peter; Johnson, Ricky; Todd, Douglas; Russell, Samuel; Walker, James

    2003-01-01

    The current inspection technique for locating interstitial leaking in the Space Shuttle Main Engine nozzles is the application of a liquid leak check solution in the openings where the interstitials space between the tubing and the structural jacket vent out the aft end of the nozzle, while its cooling tubes are pressurized to 25 psig with Helium. When a leak is found, it is classified, and if the leak is severe enough the suspect tube is cut open so that a boroscope can be inserted to find the leak point. Since the boroscope can only cover a finite tube length and since it is impossible to identify which tube (to the right or left of the identified interstitial) is leaking, many extra and undesired repairs have been made to fix just one leak. In certain instances when the interstitials are interlinked by poor braze bonding, many interstitials will show indications of leaking from a single source. What is desired is a technique that can identify the leak source so that a single repair can be performed. Dr, Samuel Russell and James Walker, both with NASA/MSFC have developed a thermographic inspection system that addresses a single repair approach. They have teamed with Boeing/Rocketdyne to repackage the inspection processes to be suitable to address full scale Shuttle development and flight hardware and implement the process at NASA centers. The methods and results presented address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera (capable of detecting a delta temperature difference of 0.025 C) is used to record the cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner hot wall surface as the nozzle is pressurized, These images are enhanced by digitally subtracting a thermal reference image taken before pressurization. The method provides a non-intrusive way of locating the tube that is leaking and the

  7. Hazard Analysis for In Tank Spray Leaks

    SciTech Connect

    GRAMS, W.H.

    2000-06-13

    The River Protection Project (RPP) Authorization Basis (AB) contains controls that address spray leaks in tanks. However, there are no hazardous conditions in the Hazards Database that specifically identify in-tank spray leak scenarios. The purpose of this Hazards Evaluation is to develop hazardous conditions related to in-tank spray leaks for the Hazards Database and to provide more complete coverage of Tank Farm facilities. Currently, the in-tank spray leak is part of the ''Spray Leak in Structures or From Waste Transfer Lines'' accidents in Section 3.4.2.9 of the Final Safety Analysis Report (FSAR) (CHG, 2000a). The accident analysis for the ''Spray Leak in Structure or From Waste Transfer Lines'' states the following regarding the location of a possible spray leak: Inside ventilated waste storage tanks (DSTs, DCRTs, and some SSTs). Aerosols could be generated inside a storage tank during a transfer because of a leak from the portion of the transfer pipe inside the tank. The tank ventilation system could help disperse the aerosols to the atmosphere should the vent system HEPA filters fail. This Hazards Evaluation also evaluates the controls currently assigned to the spray leak in structure accident and determines the applicability of the controls to the new hazardous conditions. This comparison reviews both the analysis in the FSAR and the controls found in the Technical Safety Requirements (TSRs) (CHG, 2000h). If the new hazardous conditions do not match the analyzed accident conditions and controls, then additional analysis may be required. This document is not intended to authorize the activity or determine the adequacy of controls; it is only intended to provide information about the hazardous conditions associated with this activity. The Control decision process as defined in the AB will be used to determine the adequacy of controls and whether the proposed activity is within the AB. This hazard evaluation does not constitute an accident analysis.

  8. Environmental policy -- A leaking drum?

    SciTech Connect

    Bishop, J.

    1995-07-01

    Twenty years ago, the US had virtually no overall environmental policy. Since then, one has evolved as a result of accumulated legislation, much of which was crafted in reaction to specific events, typically real or potential disasters. The familiar names of Love Canal, Times Beach, Bhopal and others are the symbolic anchor points of that evolution, which yielded Superfund, the Resource Conservation and Recovery Act, the Superfund Amendments and Reauthorization Act, and other environmental statutes. The laws in each case were developed in response to particular environmental and health issues--clean water for drinking and recreation, unpolluted air, safe production of chemicals and chemical-based products. The result was a growing body of environmental legislation that eventually became an accumulate of requirements lacking internal consistency or coherence. Because policymaking followed, rather than guided, legislative actions, the policy itself became inconsistent and sometimes illogical. Like a drum that gradually and indiscriminately is filled with a mixture of mutually reactive chemicals, environmental policy increasingly became a volatile source of concern for those industries in whose midst it had been placed. Lately, there is growing consensus that the drum not only has been overfilled, it also is leaking.

  9. Tank 241-SX-108 leak assessment

    SciTech Connect

    Not Available

    1992-05-01

    This report has been prepared by Ebasco Services Incorporated (Ebasco) under WHC Task Order MLW-SVV-037106. The work has performed under Task E-91-10. Environmental/Safety Evaluation of Waste Tank Historical Data, Subtask Tank 241-SX-108 (Tank SX-108) Leak Assessment. The intent of the work was to evaluate previous leak estimates for Tank SX-108 and to determine whether these are accurate based on all available information.

  10. mpileaks - an MPI opject leak debugging library

    SciTech Connect

    Leon, E. A.

    2011-11-14

    The mpileaks tool is to be used by MPI application developers to track and report leaked MPI objects, such as requests, groups, and datatypes. This debugging tool is useful as a quality assurance check for MPI applications, or it can be used to identify leaks fatal to long-running MPI applications. It provides an efficient method to report bugs that are otherwise fifficult to identify.

  11. Hydraulic-Leak Detector for Hidden Joints

    NASA Technical Reports Server (NTRS)

    Anderson, G. E.; Loo, S.

    1986-01-01

    Slow leakage of fluid made obvious. Indicator consists of wick wrapped at one end around joint to be monitored. Wick absorbs hydraulic fluid leaking from joint and transmits to opposite end, located outside cover plate and visible to inspector. Leakage manifested as discoloration of outside end of wick. Indicator reveals leaks in hidden fittings on hydraulic lines. Fast inspection of joints without disassembly. Used in aerospace, petroleum, chemical, nuclear, and other industries where removing covers for inspection impossible, difficult, or time-consuming.

  12. Automated Hydrogen Gas Leak Detection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Gencorp Aerojet Automated Hydrogen Gas Leak Detection System was developed through the cooperation of industry, academia, and the Government. Although the original purpose of the system was to detect leaks in the main engine of the space shuttle while on the launch pad, it also has significant commercial potential in applications for which there are no existing commercial systems. With high sensitivity, the system can detect hydrogen leaks at low concentrations in inert environments. The sensors are integrated with hardware and software to form a complete system. Several of these systems have already been purchased for use on the Ford Motor Company assembly line for natural gas vehicles. This system to detect trace hydrogen gas leaks from pressurized systems consists of a microprocessor-based control unit that operates a network of sensors. The sensors can be deployed around pipes, connectors, flanges, and tanks of pressurized systems where leaks may occur. The control unit monitors the sensors and provides the operator with a visual representation of the magnitude and locations of the leak as a function of time. The system can be customized to fit the user's needs; for example, it can monitor and display the condition of the flanges and fittings associated with the tank of a natural gas vehicle.

  13. Modeling Leaking Gas Plume Migration

    SciTech Connect

    Silin, Dmitriy; Patzek, Tad; Benson, Sally M.

    2007-08-20

    In this study, we obtain simple estimates of 1-D plume propagation velocity taking into account the density and viscosity contrast between CO{sub 2} and brine. Application of the Buckley-Leverett model to describe buoyancy-driven countercurrent flow of two immiscible phases leads to a transparent theory predicting the evolution of the plume. We obtain that the plume does not migrate upward like a gas bubble in bulk water. Rather, it stretches upward until it reaches a seal or until the fluids become immobile. A simple formula requiring no complex numerical calculations describes the velocity of plume propagation. This solution is a simplification of a more comprehensive theory of countercurrent plume migration that does not lend itself to a simple analytical solution (Silin et al., 2006). The range of applicability of the simplified solution is assessed and provided. This work is motivated by the growing interest in injecting carbon dioxide into deep geological formations as a means of avoiding its atmospheric emissions and consequent global warming. One of the potential problems associated with the geologic method of sequestration is leakage of CO{sub 2} from the underground storage reservoir into sources of drinking water. Ideally, the injected green-house gases will stay in the injection zone for a geologically long time and eventually will dissolve in the formation brine and remain trapped by mineralization. However, naturally present or inadvertently created conduits in the cap rock may result in a gas leak from primary storage. Even in supercritical state, the carbon dioxide viscosity and density are lower than those of the indigenous formation brine. Therefore, buoyancy will tend to drive the CO{sub 2} upward unless it is trapped beneath a low permeability seal. Theoretical and experimental studies of buoyancy-driven supercritical CO{sub 2} flow, including estimation of time scales associated with plume evolution, are critical for developing technology

  14. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Vacuum-side leak verification. 1065....345 Vacuum-side leak verification. (a) Scope and frequency. Verify that there are no significant vacuum-side leaks using one of the leak tests described in this section. For laboratory testing,...

  15. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Vacuum-side leak verification. 1065....345 Vacuum-side leak verification. (a) Scope and frequency. Verify that there are no significant vacuum-side leaks using one of the leak tests described in this section. For laboratory testing,...

  16. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Vacuum-side leak verification. 1065....345 Vacuum-side leak verification. (a) Scope and frequency. Verify that there are no significant vacuum-side leaks using one of the leak tests described in this section. For laboratory testing,...

  17. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Vacuum-side leak verification. 1065....345 Vacuum-side leak verification. (a) Scope and frequency. Verify that there are no significant vacuum-side leaks using one of the leak tests described in this section. For laboratory testing,...

  18. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Vacuum-side leak verification. 1065....345 Vacuum-side leak verification. (a) Scope and frequency. Verify that there are no significant vacuum-side leaks using one of the leak tests described in this section. For laboratory testing,...

  19. 40 CFR 86.328-79 - Leak checks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Leak checks. 86.328-79 Section 86.328... Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.328-79 Leak checks. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak...

  20. 40 CFR 86.328-79 - Leak checks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Leak checks. 86.328-79 Section 86.328... Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.328-79 Leak checks. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak...

  1. SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

    SciTech Connect

    VENETZ TJ; WASHENFELDER D; JOHNSON J; GIRARDOT C

    2012-01-25

    Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to

  2. Single-Shell Tanks Leak Integrity Elements/ SX Farm Leak Causes and Locations - 12127

    SciTech Connect

    Girardot, Crystal; Harlow, Don; Venetz, Theodore; Washenfelder, Dennis; Johnson, Jeremy

    2012-07-01

    Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-91F Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal 1-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX- 111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and dry-wells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to

  3. Operational Philosophy Concerning Manned Spacecraft Cabin Leaks

    NASA Technical Reports Server (NTRS)

    DeSimpelaere, Edward

    2011-01-01

    The last thirty years have seen the Space Shuttle as the prime United States spacecraft for manned spaceflight missions. Many lessons have been learned about spacecraft design and operation throughout these years. Over the next few decades, a large increase of manned spaceflight in the commercial sector is expected. This will result in the exposure of commercial crews and passengers to many of the same risks crews of the Space Shuttle have encountered. One of the more dire situations that can be encountered is the loss of pressure in the habitable volume of the spacecraft during on orbit operations. This is referred to as a cabin leak. This paper seeks to establish a general cabin leak response philosophy with the intent of educating future spacecraft designers and operators. After establishing a relative definition for a cabin leak, the paper covers general descriptions of detection equipment, detection methods, and general operational methods for management of a cabin leak. Subsequently, all these items are addressed from the perspective of the Space Shuttle Program, as this will be of the most value to future spacecraft due to similar operating profiles. Emphasis here is placed upon why and how these methods and philosophies have evolved to meet the Space Shuttle s needs. This includes the core ideas of: considerations of maintaining higher cabin pressures vs. lower cabin pressures, the pros and cons of a system designed to feed the leak with gas from pressurized tanks vs. using pressure suits to protect against lower cabin pressures, timeline and consumables constraints, re-entry considerations with leaks of unknown origin, and the impact the International Space Station (ISS) has had to the standard Space Shuttle cabin leak response philosophy. This last item in itself includes: procedural management differences, hardware considerations, additional capabilities due to the presence of the ISS and its resource, and ISS docking/undocking considerations with a

  4. Leak and Pipe Detection Method and System

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C. (Inventor)

    2003-01-01

    A method and system for locating leaks of conductive fluids from non-conductive pipes and other structures or for locat- ing non-conductive pipes or structures having conductive fluid contained therein, employ a charge generator to apply a time varying charge to the conductive fluid, and a capaci- tive type detector that can detect the variable charge that is induced in the fluid. The capacitive detector, which prefer- ably includes a handheld housing, employs a large conduc- tive pickup plate that is used to locate the pipe or leak by scanning the plate over the ground and detecting the induced charge that is generated when the plate comes in close proximity to the pipe or leak. If a leak is encountered, the resulting signal will appear over an area larger than expected for a buried pipe, assuming the leak provides an electrically conductive path between the flow and the wet surrounding ground. The detector uses any suitable type of indicator device, such as a pair of headphones that enable an operator to hear the detected signal as a chirping sound, for example.

  5. Endoscopic Management of Gastrointestinal Leaks and Fistulae.

    PubMed

    Willingham, Field F; Buscaglia, Jonathan M

    2015-10-01

    Gastrointestinal leaks and fistulae can be serious acute complications or chronic morbid conditions resulting from inflammatory, malignant, or postsurgical states. Endoscopic closure of gastrointestinal leaks and fistulae represents major progress in the treatment of patients with these complex presentations. The main goal of endoscopic therapy is the interruption of the flow of luminal contents across a gastrointestinal defect. In consideration of the proper endoscopic approach to luminal closure, several basic principles must be considered. Undrained cavities and fluid collections must often first be drained percutaneously, and the percutaneous drain provides an important measure of safety for subsequent endoscopic luminal manipulations. The size and exact location of the leak/fistula, as well as the viability of the surrounding tissue, must be defined. Almost all complex leaks and fistulae must be approached in a multidisciplinary manner, collaborating with colleagues in nutrition, radiology, and surgery. Currently, gastrointestinal leaks and fistulae may be managed endoscopically by using 1 or more of the following modalities: stent placement, clip closure (including through-the-scope clips and over-the-scope devices), endoscopic suturing, and the injection of tissue sealants. In this article, we discuss these modalities and review the published outcomes data regarding each approach as well as practical considerations for successful closure of luminal defects.

  6. Livermore study says oil leaks not severe

    SciTech Connect

    Patrick, L.

    1996-03-01

    The Petroleum Marketers Association of America (PMAA), which is working to reform the federal Leaking Underground Storage Tank program, got some strong ammunition last month. A study that the Lawrence Livermore National Laboratory performed for the California State Water Resources Control Board has found that the environmental threat of leaks is not as severe as formerly thought. The study said: such leaks rarely jeopardize drinking water; fuel hydrocarbons have limited impacts on health, the environment, and groundwater; and cleanups often are done contrary to the knowledge and experience gained from prior remediations. As a result of the study, Gov. Pete Wilson ordered California cleanups halted at sites more than 250 feet from drinking water supplies.

  7. ICPP water inventory study leak test report

    SciTech Connect

    Richards, B.T.

    1993-12-01

    Data from the Idaho Chemical Processing Plant (ICPP) indicate that there are three areas where perched water bodies (groundwater) are suspect to exist beneath the ICPP. Questions have been raised concerning the recharge sources for the northwest (NW) perched water body which is located below the northwest area of the ICPP. In response to these questions, a Water Inventory Study was initiated to determine the extent and the potential impacts of the ICPP water systems as a recharge source. A key part of the Water Inventory Study was the leak test investigation, performed to leak test the ICPP water piping distribution system, or portions thereof, which could potentially contribute to the recharge of the NW perched water body. This report provides an overview and the results of the leak test investigation and will be incorporated into the overall Water Inventory Study Report.

  8. Remote Leak Detection: Indirect Thermal Technique

    NASA Technical Reports Server (NTRS)

    Clements, Sandra

    2002-01-01

    Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.

  9. Spontaneous cerebrospinal fluid leak at the clivus

    PubMed Central

    Składzien, Jacek; Betlej, Marek; Chrzan, Robert; Mika, Joanna

    2015-01-01

    We present a case report of a 60-year-old woman with a spontaneous cerebrospinal fluid leak at the clivus, obesity and no history of trauma. Follow-up imaging scans confirmed enlargement of the defect within the posterior clival framework to the size of 16 × 9 × 4 mm with a suspected meningocerebral hernia. The surgeons used the “two nostrils – four hands” endoscopic operating technique. The patient reported a history of cerebrospinal fluid leaks lasting for 3 years, with increasingly shorter leak-free periods and an increasing incidence of inflammatory complications. The patient recovered without complications, and she was discharged 14 days after the surgery. Good local outcome and improved patient condition were achieved postoperatively. PMID:26865899

  10. Single-Shell Tank Leak Integrity Summary

    SciTech Connect

    Harlow, D. G.; Girardot, C. L.; Venetz, T. J.

    2015-03-26

    This document summarizes and evaluates the information in the Hanford Tri-Party Agreement Interim Milestone M-045-91F Targets completed between 2010 and 2015. 1) Common factors of SST liner failures (M-045-91F-T02), 2) the feasibility of testing for ionic conductivity between the inside and outside of SSTs (M-045-91F-T03, and 3) the causes, locations, and rates of leaks from leaking SSTs (M-045-91F-T04).

  11. Rankine cycle leak detection via continuous monitoring

    SciTech Connect

    Kindle, Cecil H.

    1982-10-08

    Rankine cycle power plants operate on a closed cycle in which heat is transferred from a high temperature reservoir to a low temperature sink while performing useful work. leaks in this cycle cause the loss of working fluid and/or corrosion of the power plant. Both of these constitute a loss of capital assets. A severe leak can reduce the efficiency of the cycle to the extent of creating an operating loss. PNL is undertaking the development of continuous monitoring techniques to protect rankine cycle plants from such losses. The location of these continuous monitors on an organic rankine cycle is described and shown schematically.

  12. Apparatus for Leak Testing Pressurized Hoses

    NASA Technical Reports Server (NTRS)

    Underwood, Steve D. (Inventor); Garrison, Steve G. (Inventor); Gant, Bobby D. (Inventor); Palmer, John R. (Inventor)

    2015-01-01

    A hose-attaching apparatus for leak-testing a pressurized hose may include a hose-attaching member. A bore may extend through the hose-attaching member. An internal annular cavity may extend coaxially around the bore. At least one of a detector probe hole and a detector probe may be connected to the internal annular cavity. At least a portion of the bore may have a diameter which is at least one of substantially equal to and less than a diameter of a hose to be leak-tested.

  13. Laser Schlieren System Detects Sounds Of Leaks

    NASA Technical Reports Server (NTRS)

    Shakkottai, Parthasarathy P.; Alwar, A. Vijayaragavan

    1990-01-01

    Hostile environments monitored safely and noninvasively. Modified laser schlieren system acts as microphone to detect sounds of leaks remotely. Sensitive to acoustical frequencies above audible range and especially suited for monitoring leaks of high-pressure steam from boilers or chemical vapors from processing equipment. Does not require placement of delicate equipment in harsh environment monitored, and no contact needed with boiler or other unit being monitored. Detects sound waves via variation of index of refraction of air at acoustical frequencies. Used to monitor sound frequencies beyond range of human hearing.

  14. Technique for detecting liquid metal leaks

    DOEpatents

    Bauerle, James E.

    1979-01-01

    In a system employing flowing liquid metal as a heat transfer medium in contact with tubular members containing a working fluid, i.e., steam, liquid metal leaks through the wall of the tubular member are detected by dislodging the liquid metal compounds forming in the tubular member at the leak locations and subsequently transporting the dislodged compound in the form of an aerosol to a detector responsive to the liquid metal compound. In the application to a sodium cooled tubular member, the detector would consist of a sodium responsive device, such as a sodium ion detector.

  15. Catheter-based treatment of paravalvular leaks.

    PubMed

    Taramasso, Maurizio; Maisano, Francesco; Pozzoli, Alberto; Alfieri, Ottavio; Meier, Bernhard; Nietlispach, Fabian

    2016-05-17

    The incidence of paravalvular leaks after surgical valve replacement is estimated to be 2-17%. Paravalvular leaks (PVL) can be asymptomatic and not require treatment or can cause haemolysis or heart failure. If symptomatic or if the severity of the leak is moderate or severe, redo surgery is a therapeutic option, but this is accompanied by a high perioperative risk and a high recurrence rate. A lower risk alternative is percutaneous PVL closure, with a 1-2% risk of periprocedural death or need for reoperation. These procedures are often intricate, which is reflected by a rather modest rate of procedural success (reported to be around 80%). This requires that better technical solutions become available in the future. Today, only two dedicated devices for PVL closure exist, the AMPLATZER Vascular Plug III and the paravalvular leak device. Besides, many non-dedicated devices are used, such as atrial septal occluders, ventricular septal occluders and a variety of vascular plugs. While aortic PVL are approached with a retrograde transarterial approach, mitral PVL can be approached using either an antegrade transvenous approach (transseptal), a retrograde transapical approach or, rarely, a retrograde transaortic approach. PMID:27174113

  16. Locating Small Leaks in Large Structures

    NASA Technical Reports Server (NTRS)

    Lawler, W. F.

    1983-01-01

    Test tool for detecting minute leads in bimetal joints, welds, or other locations employs fine-control valve and hypodermic needle. Test item is connected in conventional manner to helium mass spectrometer tuned to read extremely small amounts of helium gas. Uniqueness of method is ability to detect tiny leaks, through surfaces, not discoverable by gross coverage of test structures by helium gas.

  17. 40 CFR 63.1005 - Leak repair.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60..., tightening the packing gland nuts and/or ensuring that the seal flush is operating at design pressure and..., and/or replacing the bonnet bolts, and/or tightening the packing gland nuts, and/or...

  18. 40 CFR 63.1005 - Leak repair.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60..., tightening the packing gland nuts and/or ensuring that the seal flush is operating at design pressure and..., and/or replacing the bonnet bolts, and/or tightening the packing gland nuts, and/or...

  19. 40 CFR 63.1024 - Leak repair.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reading measured by Method 21 of 40 CFR part 60, appendix A at the time the leak is successfully repaired... detected. First attempt at repair for pumps includes, but is not limited to, tightening the packing gland... the bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into...

  20. 40 CFR 63.1024 - Leak repair.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reading measured by Method 21 of 40 CFR part 60, appendix A at the time the leak is successfully repaired... detected. First attempt at repair for pumps includes, but is not limited to, tightening the packing gland... the bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into...

  1. 40 CFR 63.1024 - Leak repair.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reading measured by Method 21 of 40 CFR part 60, appendix A at the time the leak is successfully repaired... detected. First attempt at repair for pumps includes, but is not limited to, tightening the packing gland... the bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into...

  2. 40 CFR 65.105 - Leak repair.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... leak. (3) Maximum instrument reading measured by Method 21 of appendix A of 40 CFR part 60 at the time.... First attempt at repair for pumps includes, but is not limited to, tightening the packing gland nuts and... bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into the...

  3. 40 CFR 65.105 - Leak repair.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... leak. (3) Maximum instrument reading measured by Method 21 of appendix A of 40 CFR part 60 at the time.... First attempt at repair for pumps includes, but is not limited to, tightening the packing gland nuts and... bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into the...

  4. 40 CFR 65.105 - Leak repair.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... leak. (3) Maximum instrument reading measured by Method 21 of appendix A of 40 CFR part 60 at the time.... First attempt at repair for pumps includes, but is not limited to, tightening the packing gland nuts and... bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into the...

  5. 40 CFR 65.105 - Leak repair.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... leak. (3) Maximum instrument reading measured by Method 21 of appendix A of 40 CFR part 60 at the time.... First attempt at repair for pumps includes, but is not limited to, tightening the packing gland nuts and... bonnet bolts, and/or tightening the packing gland nuts, and/or injecting lubricant into the...

  6. 40 CFR 63.1005 - Leak repair.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60..., tightening the packing gland nuts and/or ensuring that the seal flush is operating at design pressure and..., and/or replacing the bonnet bolts, and/or tightening the packing gland nuts, and/or...

  7. COPPER PITTING AND PINHOLE LEAK RESEARCH STUDY

    EPA Science Inventory

    Localized copper corrosion or pitting is a significant problem at many water utilities across the United States. Copper pinhole leak problems resulting from extensive pitting are widely under reported. Given the sensitive nature of the problem, extent of damage possible, costs o...

  8. [Ryanodine receptor, calcium leak and arrhythmias].

    PubMed

    Rueda, Angélica; de Alba-Aguayo, David R; Valdivia, Héctor H

    2014-01-01

    The participation of the ionic Ca(2+) release channel/ryanodine receptor in cardiac excitation-contraction coupling is well known since the late '80s, when various seminal papers communicated its purification for the first time and its identity with the "foot" structures located at the terminal cisternae of the sarcoplasmic reticulum. In addition to its main role as the Ca(2+) channel responsible for the transient Ca(2+) increase that activates the contractile machinery of the cardiomyocytes, the ryanodine receptor releases Ca(2+) during the relaxation phase of the cardiac cycle, giving rise to a diastolic Ca(2+) leak. In normal physiological conditions, diastolic Ca(2+) leak regulates the proper level of luminal Ca(2+), but in pathological conditions it participates in the generation of both, acquired and hereditary arrhythmias. Very recently, several groups have focused their efforts into the development of pharmacological tools to control the altered diastolic Ca(2+) leak via ryanodine receptors. In this review, we focus our interest on describing the participation of cardiac ryanodine receptor in the diastolic Ca(2+) leak under physiological or pathological conditions and also on the therapeutic approaches to control its undesired exacerbated activity during diastole.

  9. Microphone Detects Boiler-Tube Leaks

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P.

    1985-01-01

    Unit simple, sensitive, rugged, and reliable. Diaphragmless microphone detects leaks from small boiler tubes. Porous plug retains carbon granules in tube while allowing pressure changes to penetrate to granules. Has greater life expectancy than previous controllers and used in variety of hot corrosive atmospheres.

  10. REFLEAK: NIST Leak/Recharge Simulation Program for Refrigerant Mixtures

    National Institute of Standards and Technology Data Gateway

    SRD 73 NIST REFLEAK: NIST Leak/Recharge Simulation Program for Refrigerant Mixtures (PC database for purchase)   REFLEAK estimates composition changes of zeotropic mixtures in leak and recharge processes.

  11. 40 CFR 86.328-79 - Leak checks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... checks. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is...

  12. 40 CFR 86.328-79 - Leak checks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... checks. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is...

  13. Study of Residual Gas Analyser (RGA) Response towards Known Leaks

    NASA Astrophysics Data System (ADS)

    Pathan, Firozkhan S.; Khan, Ziauddin; Semwal, Pratibha; George, Siju; Raval, Dilip C.; Thankey, Prashant L.; Manthena, Himabindu; Yuvakiran, Paravastu; Dhanani, Kalpesh R.

    2012-11-01

    Helium leak testing is the most versatile form of weld qualification test for any vacuum application. Almost every ultra-high vacuum (UHV) system utilizes this technique for insuring leak tightness for the weld joints as well as demountable joints. During UHV system under operational condition with many other integrated components, in-situ developed leaks identification becomes one of the prime aspect for maintaining the health of such system and for continuing the experiments onwards. Since online utilization of leak detector (LD) has many practical limitations, residual gas analyser (RGA) can be used as a potential instrument for online leak detection. For this purpose, a co-relation for a given leak rate between Leak Detector and RGA is experimentally established. This paper describes the experimental aspect and the relationship between leak detector and RGA.

  14. Modeling leaks from liquid hydrogen storage systems.

    SciTech Connect

    Winters, William Stanley, Jr.

    2009-01-01

    This report documents a series of models for describing intended and unintended discharges from liquid hydrogen storage systems. Typically these systems store hydrogen in the saturated state at approximately five to ten atmospheres. Some of models discussed here are equilibrium-based models that make use of the NIST thermodynamic models to specify the states of multiphase hydrogen and air-hydrogen mixtures. Two types of discharges are considered: slow leaks where hydrogen enters the ambient at atmospheric pressure and fast leaks where the hydrogen flow is usually choked and expands into the ambient through an underexpanded jet. In order to avoid the complexities of supersonic flow, a single Mach disk model is proposed for fast leaks that are choked. The velocity and state of hydrogen downstream of the Mach disk leads to a more tractable subsonic boundary condition. However, the hydrogen temperature exiting all leaks (fast or slow, from saturated liquid or saturated vapor) is approximately 20.4 K. At these temperatures, any entrained air would likely condense or even freeze leading to an air-hydrogen mixture that cannot be characterized by the REFPROP subroutines. For this reason a plug flow entrainment model is proposed to treat a short zone of initial entrainment and heating. The model predicts the quantity of entrained air required to bring the air-hydrogen mixture to a temperature of approximately 65 K at one atmosphere. At this temperature the mixture can be treated as a mixture of ideal gases and is much more amenable to modeling with Gaussian entrainment models and CFD codes. A Gaussian entrainment model is formulated to predict the trajectory and properties of a cold hydrogen jet leaking into ambient air. The model shows that similarity between two jets depends on the densimetric Froude number, density ratio and initial hydrogen concentration.

  15. Experiences with leak rate calculations methods for LBB application

    SciTech Connect

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G.

    1997-04-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.

  16. Double Shell Tank AY-102 Radioactive Waste Leak Investigation

    SciTech Connect

    Washenfelder, Dennis J.

    2014-04-10

    PowerPoint. The objectives of this presentation are to: Describe Effort to Determine Whether Tank AY-102 Leaked; Review Probable Causes of the Tank AY-102 Leak; and, Discuss Influence of Leak on Hanford’s Double-Shell Tank Integrity Program.

  17. 49 CFR 195.444 - CPM leak detection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in...

  18. 40 CFR 63.691 - Standards: Equipment leaks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... through § 61.247 in 40 CFR part 61, subpart V—National Emission Standards for Equipment Leaks; or (2) The... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Standards: Equipment leaks. 63.691....691 Standards: Equipment leaks. (a) The provisions of this section apply to the control of...

  19. 49 CFR 195.444 - CPM leak detection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in...

  20. 40 CFR 63.691 - Standards: Equipment leaks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... through § 61.247 in 40 CFR part 61, subpart V—National Emission Standards for Equipment Leaks; or (2) The... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Standards: Equipment leaks. 63.691....691 Standards: Equipment leaks. (a) The provisions of this section apply to the control of...

  1. 49 CFR 195.134 - CPM leak detection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing...

  2. 49 CFR 195.134 - CPM leak detection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing...

  3. 49 CFR 195.134 - CPM leak detection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing...

  4. 49 CFR 195.444 - CPM leak detection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in...

  5. 40 CFR 63.691 - Standards: Equipment leaks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... through § 61.247 in 40 CFR part 61, subpart V—National Emission Standards for Equipment Leaks; or (2) The... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Standards: Equipment leaks. 63.691....691 Standards: Equipment leaks. (a) The provisions of this section apply to the control of...

  6. 49 CFR 195.134 - CPM leak detection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing...

  7. 49 CFR 195.134 - CPM leak detection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing...

  8. 10 CFR 39.35 - Leak testing of sealed sources.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Leak testing of sealed sources. 39.35 Section 39.35 Energy....35 Leak testing of sealed sources. (a) Testing and recordkeeping requirements. Each licensee who uses... record of leak test results in units of microcuries and retain the record for inspection by...

  9. 49 CFR 195.444 - CPM leak detection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in...

  10. 10 CFR 39.35 - Leak testing of sealed sources.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Leak testing of sealed sources. 39.35 Section 39.35 Energy....35 Leak testing of sealed sources. (a) Testing and recordkeeping requirements. Each licensee who uses... record of leak test results in units of microcuries and retain the record for inspection by...

  11. 40 CFR 63.691 - Standards: Equipment leaks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... through § 61.247 in 40 CFR part 61, subpart V—National Emission Standards for Equipment Leaks; or (2) The... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Standards: Equipment leaks. 63.691....691 Standards: Equipment leaks. (a) The provisions of this section apply to the control of...

  12. 49 CFR 195.444 - CPM leak detection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in...

  13. 40 CFR 63.691 - Standards: Equipment leaks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... through § 61.247 in 40 CFR part 61, subpart V—National Emission Standards for Equipment Leaks; or (2) The... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Standards: Equipment leaks. 63.691....691 Standards: Equipment leaks. (a) The provisions of this section apply to the control of...

  14. 10 CFR 35.3067 - Report of a leaking source.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Report of a leaking source. 35.3067 Section 35.3067 Energy... source. A licensee shall file a report within 5 days if a leak test required by § 35.67 reveals the... leaking source; the radionuclide and its estimated activity; the results of the test; the date of the...

  15. 1999 Leak Detection and Monitoring and Mitigation Strategy Update

    SciTech Connect

    OHL, P.C.

    1999-09-23

    This document is a complete revision of WHC-SD-WM-ES-378, Rev 1. This update includes recent developments in Leak Detection, Leak Monitoring, and Leak Mitigation technologies, as well as, recent developments in single-shell tank retrieval technologies. In addition, a single-shell tank retrieval release protection strategy is presented.

  16. The Prevention and Management of Air Leaks Following Pulmonary Resection.

    PubMed

    Burt, Bryan M; Shrager, Joseph B

    2015-11-01

    Alveolar air leaks are a common problem in the daily practice of thoracic surgeons. Prolonged air leak following pulmonary resection is associated with increased morbidity, increased length of hospital stay, and increased costs. This article reviews the evidence for the various intraoperative and postoperative options to prevent and manage postoperative air leak.

  17. 49 CFR 230.64 - Leaks under lagging.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or...

  18. 49 CFR 230.64 - Leaks under lagging.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or...

  19. 49 CFR 230.64 - Leaks under lagging.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or...

  20. 49 CFR 230.64 - Leaks under lagging.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or...

  1. 49 CFR 230.64 - Leaks under lagging.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or...

  2. Leak Detection and Location Technology Assessment for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Coffey, Neil C.; Madaras, Eric I.

    2008-01-01

    Micro Meteoroid and Orbital Debris (MMOD) and other impacts can cause leaks in the International Space Station and other aerospace vehicles. The early detection and location of leaks is paramount to astronaut safety. Therefore this document surveys the state of the art in leak detection and location technology for aerospace vehicles.

  3. Hydrogen leak detection in the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Barile, Ronald G

    1992-01-01

    This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter

  4. Method for mapping a natural gas leak

    DOEpatents

    Reichardt, Thomas A.; Luong, Amy Khai; Kulp, Thomas J.; Devdas, Sanjay

    2009-02-03

    A system is described that is suitable for use in determining the location of leaks of gases having a background concentration. The system is a point-wise backscatter absorption gas measurement system that measures absorption and distance to each point of an image. The absorption measurement provides an indication of the total amount of a gas of interest, and the distance provides an estimate of the background concentration of gas. The distance is measured from the time-of-flight of laser pulse that is generated along with the absorption measurement light. The measurements are formatted into an image of the presence of gas in excess of the background. Alternatively, an image of the scene is superimposed on the image of the gas to aid in locating leaks. By further modeling excess gas as a plume having a known concentration profile, the present system provides an estimate of the maximum concentration of the gas of interest.

  5. Hydrogen leak detection in the Space Shuttle

    NASA Astrophysics Data System (ADS)

    Barile, Ronald G.

    1992-09-01

    This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter

  6. Natural gas pipeline leaks across Washington, DC.

    PubMed

    Jackson, Robert B; Down, Adrian; Phillips, Nathan G; Ackley, Robert C; Cook, Charles W; Plata, Desiree L; Zhao, Kaiguang

    2014-01-01

    Pipeline safety in the United States has increased in recent decades, but incidents involving natural gas pipelines still cause an average of 17 fatalities and $133 M in property damage annually. Natural gas leaks are also the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. To reduce pipeline leakage and increase consumer safety, we deployed a Picarro G2301 Cavity Ring-Down Spectrometer in a car, mapping 5893 natural gas leaks (2.5 to 88.6 ppm CH4) across 1500 road miles of Washington, DC. The δ(13)C-isotopic signatures of the methane (-38.2‰ ± 3.9‰ s.d.) and ethane (-36.5 ± 1.1 s.d.) and the CH4:C2H6 ratios (25.5 ± 8.9 s.d.) closely matched the pipeline gas (-39.0‰ and -36.2‰ for methane and ethane; 19.0 for CH4/C2H6). Emissions from four street leaks ranged from 9200 to 38,200 L CH4 day(-1) each, comparable to natural gas used by 1.7 to 7.0 homes, respectively. At 19 tested locations, 12 potentially explosive (Grade 1) methane concentrations of 50,000 to 500,000 ppm were detected in manholes. Financial incentives and targeted programs among companies, public utility commissions, and scientists to reduce leaks and replace old cast-iron pipes will improve consumer safety and air quality, save money, and lower greenhouse gas emissions.

  7. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    SciTech Connect

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G.

    1995-04-01

    Regulatory Guide 1.45, {open_quotes}Reactor Coolant Pressure Boundary Leakage Detection Systems,{close_quotes} was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, {open_quotes}Leak Before Break Evaluation Procedures{close_quotes} where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break.

  8. Airborne pipeline leak detection: UV or IR?

    NASA Astrophysics Data System (ADS)

    Babin, François; Gravel, Jean-François; Allard, Martin

    2016-05-01

    This paper presents a study of different approaches to the measurement of the above ground vapor plume created by the spill caused by a small 0.1 l/min (or less) leak in an underground liquid petroleum pipeline. The scenarios are those for the measurement from an airborne platform. The usual approach is that of IR absorption, but in the case of liquid petroleum products, there are drawbacks that will be discussed, especially when using alkanes to detect a leak. The optical measurements studied include UV enhanced Raman lidar, UV fluorescence lidar and IR absorption path integrated lidars. The breadboards used for testing the different approaches will be described along with the set-ups for leak simulation. Although IR absorption would intuitively be the most sensitive, it is shown that UV-Raman could be an alternative. When using the very broad alkane signature in the IR, the varying ground spectral reflectance are a problem. It is also determined that integrated path measurements are preferred, the UV enhanced Raman measurements showing that the vapor plume stays very close to the ground.

  9. Automated software system reduces leak investigation time

    SciTech Connect

    Not Available

    1994-12-01

    With more than a million customers in the New York City boroughs of Brooklyn, Queens, and Staten Island, Brooklyn Union Gas Co. is one of the largest natural gas distributors in the US. In September 1993, the company began working with MapFrame Corp., Dallas, to develop a new program to automate their underground leak investigation process. Automating this process would greatly reduce time in finding a leaking main and result in improved customer relations and productivity gains. Keys to the success of this program were in using pen computers, wireless communications, and a jointly-developed software. MapFrame and Brooklyn Union Gas agreed that the application should allow onsite users to: display a model of the affected area using map data to show streets, services, buildings, manholes, street lights, and other landmarks; record bar hole readings, manipulate data, and use diagnostic tools to analyze gas concentrations; update leak records (per legal requirements); and integrate Map Data. The paper reviews this program.

  10. Imaging spectrometer for fugitive gas leak detection

    NASA Astrophysics Data System (ADS)

    Hinnrichs, Michele

    1999-12-01

    Under contract to the U.S. Air Force and Navy, Pacific Advanced Technology has developed a very sensitive infrared imaging spectrometer that can perform remote imaging and spectro-radiometry. One of the most exciting applications for this technology is in the remote monitoring of smoke stack emissions and fugitive leaks. To date remote continuous emission monitoring (CEM) systems have not been approved by the EPA, however, they are under consideration. If the remote sensing technology is available with the sensitivity to monitor emission at the required levels and man portable it can reduce the cost and improve the reliability of performing such measurements. Pacific Advanced Technology (PAT) believes that it currently has this technology available to industry. This paper will present results from a field test where gas vapors during a refueling process were imaged and identified. In addition images of propane from a leaking stove will be presented. We at PAT have developed a real time image processing board that enhances the signal to noise ratio of low contrast gases and makes them easily viewable using the Image Multispectral Sensing (IMSS) imaging spectrometer. The IMSS imaging spectrometer is the size of a camcorder. Currently the data is stored in a Notebook computer thus allowing the system to be easily carried into power plants to look for fugitive leaks. In the future the IMSS will have an embedded processor and DSP and will be able to transfer data over an Ethernet link.

  11. Waste Transfer Leaks Control Decision Record

    SciTech Connect

    RYAN, G.W.

    2000-06-27

    Control decision meetings for Waste Transfer Leaks were held on April 24,25,26, and 27, 2000. The agenda for the control decision meetings is included in Appendix A, and attendee lists are included in Appendix B. The purpose of the control decision meetings was to review and revise previously selected controls for the prevention or mitigation of waste transfer leak accidents. Re-evaluation of the controls is warranted due to revisions in the hazard and accident analysis for these Tank Farm events. In particular, calculated radiological consequences are significantly reduced from those currently reported in the Final Safety Analysis Report (FSAR). Revised hazard and accident analysis and a revised control recommendation will be reflected in an Authorization Basis Amendment to be submitted at the Department of Energy, Office of River Protection's (ORP's) request by June 30, 2000 to satisfy ORP Performance Incentive (PI) 2.1.1, Revision 1, ''Authorization Basis Management Process Efficiency Improvement''. The scope of the control decision meetings was to address all waste transfer leak-related hazardous conditions identified in the Tank Farm hazard analysis database, excluding those associated with the use of the Replacement Cross-Site Transfer System (RCSTS) slurry line and sluicing of Tank 241-C-106, which is addressed in FSAR Addendum 1. The scope of this control decision process does include future waste feed delivery waste transfer operations.

  12. Detection of interstate liquids pipeline leaks: Feasibility evaluation

    SciTech Connect

    Dietz, R.N.; Senum, G.I.

    1998-10-20

    The approximately 200,000-mile fuel pipeline system in the US operates at flow rates up to 2.5 {times} 10{sup 6} gallons per hour (GPH). Most commercial technologies only provide on-line leak detection at about 0.3% of flow rate, i.e., about 7,500 GPH or larger. Detection of leaks at about 1 GPH or so is desirable both from a regulatory and leak-prevention standpoint. Brookhaven`s commercially-accepted perfluorocarbon tracer (PFT) technology for underground leak detection of utility industry dielectric fluids at leak rates less than 0.1 GPH, with new enhancements, will be able to cost-effectively detect fuel pipeline system leaks to about 1 GPH--3 orders-of-magnitude better than any on-line system. The magnitude of detected leaks would be calculable as well. Proposed mobile surveys (such as those used periodically in the gas pipeline industry) at about 110 to 120 miles per day would allow such small leaks to be detected at 10-ppb tagging levels (less than $1,500 of PFT for a 48-hour tag at the maximum transport rate) under worst-case meteorological dispersion conditions. Smaller leaks could be detected by proportionately larger tagging concentrations. Leaks would be pinpointed by subsequent conventional barholing and vapor analyses. There are no health nor safety issues associated with the use of the proposed technological approach nor any consequential environmental impacts associated with the proposed magnitudes of PFT tagging.

  13. DETECTION OF INTERSTATE LIQUIDS PIPELINE LEAKS: FEASIBILITY EVALUATION.

    SciTech Connect

    DIETZ,R.N.

    1998-10-20

    The approximately 200,000-mile fuel pipeline system in the U.S. operates at flow rates up to 2.5 x 10{sup 6}gallons per hour (GPH). Most commercial technologies only provide on-line leak detection at about 0.3% of flow rate, i.e., about 7,500 GPH or larger. Detection of leaks at about 1 GPH or so is desirable both from a regulatory and leak-prevention standpoint. Brookhaven's commercially-accepted perfluorocarbon tracer (PFT) technology for underground leak detection of utility industry dielectric fluids at leak rates less than 0.1 GPH, with new enhancements, will be able to cost-effectively detect fuel pipeline system leaks to about 1 GPH--3 orders-of-magnitude better than any on-line system. The magnitude of detected leaks would be calculable as well. Proposed mobile surveys (such as those used periodically in the gas pipeline industry) at about 110 to 120 miles per day would allow such small leaks to be detected at 10-ppb tagging levels (less than $1,500 of PFT for a 48-hour tag at the maximum transport rate) under worst-case meteorological dispersion conditions. Smaller leaks could be detected by proportionately larger tagging concentrations. Leaks would be pinpointed by subsequent conventional barholing and vapor analyses. There are no health nor safety issues associated with the use of the proposed technological approach nor any consequential environmental impacts associated with the proposed magnitudes of PFT tagging.

  14. LEAK: A source term generator for evaluating release rates from leaking vessels

    SciTech Connect

    Clinton, J.H.

    1994-09-01

    An interactive computer code for estimating the rate of release of any one of several materials from a leaking tank or broken pipe leading from a tank is presented. It is generally assumed that the material in the tank is liquid. Materials included in the data base are acetonitrile, ammonia, carbon tetrachloride, chlorine, chlorine trifluoride, fluorine, hydrogen fluoride, nitric acid, nitrogen tetroxide, sodium hydroxide, sulfur hexafluoride, sulfuric acid, and uranium hexafluoride. Materials that exist only as liquid and/or vapor over expected ranges of temperature and pressure can easily be added to the data base file. The Fortran source code for LEAK and the data file are included with this report.

  15. 340 Facility secondary containment and leak detection

    SciTech Connect

    Bendixsen, R.B.

    1995-01-31

    This document presents a preliminary safety evaluation for the 340 Facility Secondary Containment and Leak Containment system, Project W-302. Project W-302 will construct Building 340-C which has been designed to replace the current 340 Building and vault tank system for collection of liquid wastes from the Pacific Northwest Laboratory buildings in the 300 Area. This new nuclear facility is Hazard Category 3. The vault tank and related monitoring and control equipment are Safety Class 2 with the remainder of the structure, systems and components as Safety Class 3 or 4.

  16. Low heat-leak cryogenic envelope

    DOEpatents

    DeHaan, James R.

    1976-10-19

    A plurality of cryogenic envelope sections are joined together to form a power transmission line. Each of the sections is comprised of inner and outer tubes having multilayer metalized plastic spirally wrapped within a vacuum chamber formed between the inner and outer tubes. A refrigeration tube traverses the vacuum chamber, but exits one section and enters another through thermal standoffs for reducing heat-leak from the outer tube to the refrigeration tube. The refrigeration tube passes through a spirally wrapped shield within each section's vacuum chamber in a manner so that the refrigeration tube is in close thermal contact with the shield, but is nevertheless slideable with respect thereto.

  17. One-Piece Leak-Proof Battery

    DOEpatents

    Verhoog, Roelof

    1999-03-23

    The casing of a leak-proof one-piece battery is made of a material comprising a mixture of at least a matrix based on polypropylene and an alloy of a polyamide and a polypropylene. The ratio of the matrix to the alloy is in the range 0.5 to 6 by weight. The alloy forms elongate arborescent inclusions in the matrix such that, on average, the largest dimension of a segment of the arborescence is at least twenty times the smallest dimension of the segment.

  18. Petroleum pipeline leak detection study. Final report

    SciTech Connect

    Mastandrea, J.R.

    1982-03-01

    This study reviews and analyzes the U.S. petroleum pipeline system, accidental spills, and spill prevention programs. It concludes that improved pipeline spill prevention measures are needed, because pipeline systems are aging, population densities near lines are increasing dramatically, and new lines are expected to be larger and longer. An approach to developing a spill prevention program is presented. Then, recommended spill prevention programs for individual pipeline systems are described. These programs consist of scheduled inspection and/or leak detection methods and are shown to be capable of significantly reducing the risk of serious spills. Practical considerations such as the cost of inspections and spillage are also included.

  19. Carbon granule probe microphone for leak detection

    NASA Astrophysics Data System (ADS)

    Parthasarathy, S. P.

    1985-02-01

    A microphone which is not subject to corrosion is provided by employing carbon granules to sense sound waves. The granules are packed into a ceramic tube and no diaphragm is used. A pair of electrodes is located in the tube adjacent the carbon granules and are coupled to a sensing circuit. Sound waves cause pressure changes on the carbon granules which results in a change in resistance in the electrical path between the electrodes. This change in resistance is detected by the sensing circuit. The microphone is suitable for use as a leak detection probe in recovery boilers, where it provides reliable operation without corrosion problems associated with conventional microphones.

  20. A hydrogen leak detection system for aerospace and commercial applications

    NASA Astrophysics Data System (ADS)

    Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1995-10-01

    Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.

  1. Long-life leak standard assembly. [Patent application

    DOEpatents

    Basford, J.A.; Mathis, J.E.; Wright, H.C.

    1980-11-12

    The present invention is directed to a portable leak standard assembly which is capable of providing a stream of high-purity reference gas at a virtually constant flow rate over an extensive period of time. The leak assembly comprises a high pressure reservoir coupled to a metal leak valve through a valve-controlled conduit. A reproducible leak valve useful in this assembly is provided by a metal tube crimped with a selected pressure loading for forming an orifice in the tube with this orifice being of a sufficient size to provide the selected flow rate. The leak valve assembly is formed of metal so that it can be baked-out in a vacuum furnace to rid the reservoir and attendent components of volatile impurities which reduce the efficiency of the leak standard.

  2. A Hydrogen Leak Detection System for Aerospace and Commercial Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1995-01-01

    Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.

  3. Comparison of helium leak test and vacuum leak test using canned foods: collaborative study.

    PubMed

    Rhea, U S; Gilchrist, J E; Peeler, J T; Shah, D B

    1984-01-01

    Two can leak tests were compared by 7 collaborators. In the helium leak test, pressurized helium is applied to the outside of the container, and a headspace gas sample from the can is then analyzed for the presence of helium. The vacuum test is described in the Bacteriological Analytical Manual. Ninety No. 303 cans of creamed-style corn, green beans, carrots, fruit cocktail, and whole-kernel corn were shipped in 3 groups. Two groups of 30 cans had 10 dented flat cans, 5 flat controls (nondented), 10 dented swollen cans, and 5 swollen control cans (nondented). The third group had 10 dented swollen cans and 5 swollen control cans. Of 600 cans analyzed, 37 (6.2%) were deleted from the analysis because results were not available for both tests. One laboratory was constrained by scheduling to analyze 15 of 45 swollen cans. The helium leak test found 12 (13%) positives of 92 nondented swollen cans. One pressurization test yielded 7 of those 12 positives. Of the 400 dented cans sent as possible leakers, the helium test found 267 positives, and the vacuum test found 181. Five of the 7 analysts had significantly (alpha = 0.05) higher percent positive helium results. One analyst found more leakers by the vacuum leak test. Both tests found fewer positives in the swollen dented cans than in the flat dented cans. After exposure to pressurized helium, all cans with greater than 8 psi headspace pressure were positive helium leakers. The method was adopted official first action.

  4. Leak locating microphone, method and system for locating fluid leaks in pipes

    DOEpatents

    Kupperman, David S.; Spevak, Lev

    1994-01-01

    A leak detecting microphone inserted directly into fluid within a pipe includes a housing having a first end being inserted within the pipe and a second opposed end extending outside the pipe. A diaphragm is mounted within the first housing end and an acoustic transducer is coupled to the diaphragm for converting acoustical signals to electrical signals. A plurality of apertures are provided in the housing first end, the apertures located both above and below the diaphragm, whereby to equalize fluid pressure on either side of the diaphragm. A leak locating system and method are provided for locating fluid leaks within a pipe. A first microphone is installed within fluid in the pipe at a first selected location and sound is detected at the first location. A second microphone is installed within fluid in the pipe at a second selected location and sound is detected at the second location. A cross-correlation is identified between the detected sound at the first and second locations for identifying a leak location.

  5. Design Review Report for S and SX Farm Leak Detectors

    SciTech Connect

    LAMPHERE, J.E.

    2000-01-28

    The design for S and SX Farm Leak Detector ECN (649594) provides leak detection for valve pits S-A and S-B the Over Ground Transfer (OGT) conduit installation for the leak detection in COB No.10 between No.10 and PICS at 241-5-106 The Design Review was held 11/20/98 All comments received on RCR forms during the meeting are recorded on the meeting minutes were resolved and incorporated to the satisfaction reviewers.

  6. Offsite radiological consequence analysis for the waste transfer leak

    SciTech Connect

    ZIMMERMAN, B.D.

    2003-03-21

    This document quantifies the offsite radiological/consequence of the bounding waste transfer leak accident for comparison with the 25 rem Evaluation Guideline established in DOE-STD-3009, Appendix A. The bounding waste transfer leak accident is a fine spray leak into the air. The calculation applies reasonably conservative input parameters in accordance with DOE-STD-3009, Appendix A, guidance. The calculated offsite dose of 0.7 rem does not challenge the Evaluation Guideline.

  7. Boston Gas tackles leaks with unique drilling rigs

    SciTech Connect

    1994-01-01

    This paper reviews a new drilling method and new drilling equipment used to pinpoint gas leaks in urban areas. It describes the drill spacing and drilling time involved in finding such leaks. It discusses the size of the drilling equipment and speed of penetration through various materials, including frozen soils. The use of this equipment has dramatically increased the speed necessary to identify the leak and instigate repairs.

  8. Drain amylase aids detection of anastomotic leak after esophagectomy

    PubMed Central

    Baker, Erin H.; Hill, Joshua S.; Reames, Mark K.; Symanowski, James; Hurley, Susie C.

    2016-01-01

    Background Anastomotic leak following esophagectomy is associated with significant morbidity and mortality. As hospital length of stay decreases, the timely diagnosis of leak becomes more important. We evaluated CT esophagram, white blood count (WBC), and drain amylase levels in the early detection of anastomotic leak. Methods The diagnostic performance of CT esophagram, drain amylase >800 IU/L, and WBC >12,000/µL within the first 10 days after surgery in predicting leak at any time after esophagectomy was calculated. Results Anastomotic leak occurred in 13 patients (13%). CT esophagram performed within 10 days of surgery diagnosed six of these leaks with a sensitivity of 0.54. Elevation in drain amylase level within 10 days of surgery diagnosed anastomotic leak with a sensitivity of 0.38. When the CT esophagram and drain amylase were combined, the sensitivity rose to 0.69 with a specificity of 0.98. WBC elevation had a sensitivity of 0.92, with a specificity of 0.34. Among 30 patients with normal drain amylase and a normal WBC, one developed an anastomotic leak. Conclusions Drain amylase adds to the sensitivity of CT esophagram in the early detection of anastomotic leak. Selected patients with normal drain amylase levels and normal WBC may be able to safely forgo CT esophagram. PMID:27034784

  9. Margins in high temperature leak-before-break assessments

    SciTech Connect

    Budden, P.J.; Hooton, D.G.

    1997-04-01

    Developments in the defect assessment procedure R6 to include high-temperature mechanisms in Leak-before-Break arguments are described. In particular, the effect of creep on the time available to detect a leak and on the crack opening area, and hence leak rate, is discussed. The competing influence of these two effects is emphasized by an example. The application to Leak-before-Break of the time-dependent failure assessment diagram approach for high temperature defect assessment is then outlined. The approach is shown to be of use in assessing the erosion of margins by creep.

  10. Lymphangiography in the Diagnosis and Localization of Various Chyle Leaks

    SciTech Connect

    Deso, Steve; Ludwig, Benjamin; Kabutey, Nii-Kabu; Kim, Ducksoo; Guermazi, Ali

    2012-02-15

    Purpose: Chyle leaks are rare entities infrequently encountered by most physicians. However, large centers providing advanced surgical care are inevitably confronted with chyle leaks as a complication of surgery, an extension of disease, or as a primary disorder. Regardless of the etiology, proper diagnosis and localization are paramount in the management of any chyle leak. Materials and Methods: Here we present 16 patients with 17 chyle leaks (5 chyluria, 8 chylothorax, and 4 chylous ascites) who underwent bipedal lymphangiography (LAG) and postprocedure computed tomography (CT) imaging. Results: In each case, the source of the chyle leak was identified and properly localized to guide further treatment. Of the 16 patients who underwent LAG and postprocedure CT imaging, the initial LAG alone provided the diagnosis and localized the chyle leak in 4 patients (25%); the postprocedure CT imaging provided the diagnosis and localized the chyle leak in 6 patients (37.5%); and the two modalities were equal in the diagnosing and localizing the chyle leak in the remaining 6 patients (37.5%)ConclusionThese cases highlight the unparalleled abilities of LAG and the added benefit of post-LAG CT imaging in the diagnosis and fine anatomic localization of chyle leaks. In addition, these cases demonstrate the retained utility of LAG in these investigations despite the development of alternative tests involving CT, magnetic resonance imaging, and nuclear medicine imaging.

  11. Leak-tight vertical membrane microvalves.

    PubMed

    Hansson, Jonas; Hillmering, Mikael; Haraldsson, Tommy; van der Wijngaart, Wouter

    2016-04-21

    Pneumatic microvalves are fundamental control components in a large range of microfluidic applications. Their key performance parameters are small size, i.e. occupying a minimum of microfluidic real estate, low flow resistance in the open state, and leak-tight closing at limited control pressures. In this work we present the successful design, realization and evaluation of the first leak-tight, vertical membrane, pneumatic microvalves. The realization of the vertical membrane microvalves is enabled by a novel dual-sided molding method for microstructuring monolithic 3D microfluidic networks in PDMS in a single step, eliminating the need for layer-to-layer alignment during bonding. We demonstrate minimum lateral device features down to 20-30 μm in size, and vertical via density of ∼30 000 per cm(2), which provides significant gains in chip real estate compared to previously reported PDMS manufacturing methods. In contrast to horizontal membrane microvalves, there are no manufacturing restrictions on the cross-sectional geometry of the flow channel of the vertical membrane microvalves. This allows tuning the design towards lower closing pressure or lower open state flow resistance compared to those of horizontal membrane microvalves. PMID:26983557

  12. Idiopathic systemic capillary leak syndrome in children.

    PubMed

    Hsu, Peter; Xie, Zhihui; Frith, Katie; Wong, Melanie; Kakakios, Alyson; Stone, Kelly D; Druey, Kirk M

    2015-03-01

    Adult subjects with systemic capillary leak syndrome (SCLS) present with acute and recurrent episodes of vascular leak manifesting as severe hypotension, hypoalbuminemia, hemoconcentration, and generalized edema. We studied clinical disease characteristics, serum cytokine profiles, and treatment modalities in a cohort of children with documented SCLS. Six children with SCLS were recruited from the United States, Australia, Canada, and Italy. Serum cytokines from SCLS subjects and a group of 10 healthy children were analyzed. Children with SCLS (aged 5-11 years old) presented with at least 1 acute, severe episode of hypotension, hypoalbuminemia, and hemoconcentration in the absence of underlying causes for these abnormalities. In contrast to what is observed in adult SCLS, identifiable infectious triggers precipitated most episodes in these children, and none of them had a monoclonal gammopathy. We found elevated levels of chemokine (C-C motif) ligand 2 (CCL2), interleukin-8, and tumor necrosis factor α in baseline SCLS sera compared with the control group. All patients are alive and well on prophylactic therapy, with 4 patients receiving intravenous or subcutaneous immunoglobulins at regular intervals. The clinical manifestations of pediatric and adult SCLS are similar, with the notable exceptions of frequent association with infections and the lack of monoclonal gammopathy. Prophylactic medication, including high dose immunoglobulins or theophylline plus verapamil, appears to be safe and efficacious therapy for SCLS in children. PMID:25713284

  13. Acoustic leak detection and ultrasonic crack detection

    SciTech Connect

    Kupperman, D.S.; Claytor, T.N.; Groenwald, R.

    1983-10-01

    A program is under way to assess the effectiveness of current and proposed techniques for acoustic leak detection (ALD) in reactor coolant systems. An ALD facility has been constructed and tests have begun on five laboratory-grown cracks (three fatigue and two thermal-fatigue and two field-induced IGSCC specimens. After ultrasonic testing revealed cracks in the Georgia Power Co. HATCH-1 BWR recirculation header, the utility installed an ALD system. Data from HATCH-1 have given an indication of the background noise level at a BWR recirculation header sweepolet weld. The HATCH leak detection system was tested to determine the sensitivity and dynamic range. Other background data have been acquired at the Watts Bar Nuclear Reactor in Tennessee. An ANL waveguide system, including transducer and electronics, was installed and tested on an accumulator safety injection pipe. The possibility of using ultrasonic wave scattering patterns to discriminate between IGSCCs and geometric reflectors has been explored. Thirteen reflectors (field IGSCCs, graphite wool IGSCCs, weld roots, and slits) were examined. Work with cast stainless steel (SS) included sound velocity and attenuation in isotropic and anisotropic cast SS. Reducing anisotropy does not help reduce attenuation in large-grained material. Large artificial flaws (e.g., a 1-cm-deep notch with a 4-cm path) could not be detected in isotropic centrifugally cast SS (1 to 2-mm grains) by longitudinal or shear waves at frequencies of 1 MHz or greater, but could be detected with 0.5-MHz shear waves. 13 figures.

  14. Comprehensive leak detection survey and benefit/cost analysis

    SciTech Connect

    Scholze, R.J. Jr.; Maloney, S.W.

    1995-06-01

    Fort Carson, Colorado was the site of a comprehensive leak detection investigation of the potable water system with the express purpose of quantifying the benefits to be derived by a military installation from use of leak detection and repair technology. Military bases are often the size of a small city and one Directorate or Department has responsibility for all real estate (buildings, roads, grounds, etc.) unlike a municipal public works department. The investigation used state of the art noise correlation and computer correlation technology to survey the distribution system mains. This was complemented by a building to building survey covering office and commercial buildings along with family and barracks housing where investigators entered buildings and quantified visible leaks in faucets and water closets, etc. Following repairs and a year`s time, a follow-on survey is performed to again examine all aspects of the system. The result was a complete economic evaluation and benefit/cost analysis of the installation. Representative findings include: the majority of distribution system leaks were at hydrants or similar appurtenances; and family housing was found to be the other major concentration of leaks. However, where the first survey found 80 percent of housing units had leaks, findings from the second round on the order of 20 percent. Office buildings were found from the first survey to not merit follow-on attention due to limited numbers of leaks. Water-consciousness was raised for both the responsible directorate and individuals in family housing and leak repair was given a higher priority for repairs. This paper will outline the leak detection methodology used, characterize the types and patterns of leaks found, introduce an economic analysis for the entire leak detection process, and finally, provide lessons learned with practical results and implications.

  15. Heat exchanger with leak detecting double wall tubes

    DOEpatents

    Bieberbach, George; Bongaards, Donald J.; Lohmeier, Alfred; Duke, James M.

    1981-01-01

    A straight shell and tube heat exchanger utilizing double wall tubes and three tubesheets to ensure separation of the primary and secondary fluid and reliable leak detection of a leak in either the primary or the secondary fluids to further ensure that there is no mixing of the two fluids.

  16. 40 CFR 1065.644 - Vacuum-decay leak rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak...

  17. 40 CFR 1065.644 - Vacuum-decay leak rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak...

  18. 40 CFR 1065.644 - Vacuum-decay leak rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak...

  19. 40 CFR 1065.644 - Vacuum-decay leak rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak...

  20. 40 CFR 1065.644 - Vacuum-decay leak rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Vacuum-decay leak rate. 1065.644 Section 1065.644 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.644 Vacuum-decay leak...

  1. A voice-actuated wind tunnel model leak checking system

    NASA Technical Reports Server (NTRS)

    Larson, W. E.

    1985-01-01

    A voice-actuated wind tunnel model leak checking system was developed. The system uses a voice recognition and response unit to interact with the technician along with a graphics terminal to provide the technician with visual feedback while checking a model for leaks.

  2. 40 CFR 61.135 - Standard: Equipment leaks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emissions from Coke By-Product Recovery Plants § 61.135 Standard: Equipment leaks. (a) Each owner or operator of equipment in benzene service shall comply with the requirements of 40 CFR part 61, subpart V... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Standard: Equipment leaks....

  3. 40 CFR 61.135 - Standard: Equipment leaks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emissions from Coke By-Product Recovery Plants § 61.135 Standard: Equipment leaks. (a) Each owner or operator of equipment in benzene service shall comply with the requirements of 40 CFR part 61, subpart V... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Standard: Equipment leaks....

  4. 40 CFR 61.135 - Standard: Equipment leaks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emissions from Coke By-Product Recovery Plants § 61.135 Standard: Equipment leaks. (a) Each owner or operator of equipment in benzene service shall comply with the requirements of 40 CFR part 61, subpart V... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Standard: Equipment leaks....

  5. 40 CFR 61.135 - Standard: Equipment leaks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emissions from Coke By-Product Recovery Plants § 61.135 Standard: Equipment leaks. (a) Each owner or operator of equipment in benzene service shall comply with the requirements of 40 CFR part 61, subpart V... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Standard: Equipment leaks....

  6. 40 CFR 63.1434 - Equipment leak provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... HON equipment leak requirements in 40 CFR part 63, subpart H for all equipment in organic HAP service... Initial Notification requirements contained in §§ 63.182(a)(1) and 63.182(b) are referred to in 40 CFR... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Equipment leak provisions....

  7. 40 CFR 61.135 - Standard: Equipment leaks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emissions from Coke By-Product Recovery Plants § 61.135 Standard: Equipment leaks. (a) Each owner or operator of equipment in benzene service shall comply with the requirements of 40 CFR part 61, subpart V... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Standard: Equipment leaks....

  8. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    SciTech Connect

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.; Joslyn, Cameron C.; Vazquez, Brandon J.; Venetz, Theodore J.; Garfield, John S.

    2014-01-20

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line.

  9. Transcatheter treatment of Starr-Edwards paravalvular leaks.

    PubMed

    Santoro, Giuseppe; Scognamiglio, Giancarlo; Gaio, Gianpiero; Iacono, Carola; Giugno, Luca; Russo, Maria G

    2014-06-28

    A 56-year-old patient was referred because of refractory heart failure and mild haemolysis caused by multiple, severe paravalvular leaks of a Starr-Edwards valve implanted in mitral position 23 years before. Owing to perceived high risk of surgical re-valving, percutaneous paravalvular leak occlusion was performed by implantation of multiple, simultaneously deployed Amplatzer Vascular Plugs.

  10. HIGH RESOLUTION RESISTIVITY LEAK DETECTION DATA PROCESSING & EVALUATION MEHTODS & REQUIREMENTS

    SciTech Connect

    SCHOFIELD JS

    2007-10-04

    This document has two purposes: {sm_bullet} Describe how data generated by High Resolution REsistivity (HRR) leak detection (LD) systems deployed during single-shell tank (SST) waste retrieval operations are processed and evaluated. {sm_bullet} Provide the basic review requirements for HRR data when Hrr is deployed as a leak detection method during SST waste retrievals.

  11. Air leak after lung resection: pathophysiology and patients’ implications

    PubMed Central

    Miserocchi, Giuseppe

    2016-01-01

    Protocols for the management of air leaks are critical aspects in the postoperative course of patients following lung resections. Many investigations in the last decade are focusing on the chest tube modalities or preventative measures, however, little is known about the pathophysiology of air leak and the patient perception of this common complication. This review concentrates on understanding the reasons why a pulmonary parenchyma may start to leak or an air leak may be longer than others. Experimental works support the notion that lung overdistension may favor air leak. These studies may represent the basis of future investigations. Furthermore, the standardization of nomenclature in the field of pleural space management and the creation of novel air leak scoring systems have contributed to improve the knowledge among thoracic surgeons and facilitate the organization of trials on this matter. We tried to summarize available evidences about the patient perception of a prolonged air leak and about what would be useful for them in order to prevent worsening of their quality of life. Future investigations are warranted to better understand the pathophysiologic mechanisms responsible of prolonged air leak in order to define tailored treatments and protocols. Improving the care at home with web-based telemonitoring or real time connected chest drainage may in a future improve the quality of life of the patients experience this complication and also enhance hospital finances. PMID:26941970

  12. Fiber-Optic System Would Detect Leaking Liquid H2

    NASA Technical Reports Server (NTRS)

    Grove, Charles H.

    1993-01-01

    Proposed instrument based on optical time-domain reflectometry measures both locations and sizes of leaks in tanks and plumbing storing and transferring liquid hydrogen. Conceived for use in detecting leaks of hydrogen from propulsion system of Space Shuttle, concept applicable to detection of flammable and/or poisonous fumes in chemical-processing plants, fuel-distributing equipment, and other terrestrial applications.

  13. Cerebral vascular leak in a mouse model of amyloid neuropathology

    PubMed Central

    Tanifum, Eric A; Starosolski, Zbigniew A; Fowler, Stephanie W; Jankowsky, Joanna L; Annapragada, Ananth V

    2014-01-01

    In Alzheimer's disease (AD), there is increasing evidence of blood–brain barrier (BBB) compromise, usually observed as ‘microbleeds' correlated with amyloid plaque deposition and apoE-ɛ4 status, raising the possibility of nanotherapeutic delivery. Molecular probes have been used to study neurovascular leak, but this approach does not adequately estimate vascular permeability of nanoparticles. We therefore characterized cerebrovascular leaks in live APP+ transgenic animals using a long circulating ∼100 nm nanoparticle computed tomography (CT) contrast agent probe. Active leaks fell into four categories: (1) around the dorsomedial cerebellar artery (DMCA), (2) around other major vessels, (3) nodular leaks in the cerebral cortex, and (4) diffuse leaks. Cortical leaks were uniformly more frequent in the transgenic animals than in age-matched controls. Leaks around vessels other than the DMCA were more frequent in older transgenics compared with younger ones. All other leaks were equally prevalent across genotypes independent of age. Ten days after injection, 4 to 5 μg of the dose was estimated to be present in the brain, roughly a half of which was in locations other than the leaky choroid plexus, and associated with amyloid deposition in older animals. These results suggest that amyloid deposition and age increase delivery of nanoparticle-borne reagents to the brain, in therapeutically relevant amounts. PMID:25052555

  14. Management of Anterior Skull Base Cerebrospinal Fluid Leaks.

    PubMed

    Le, Christopher; Strong, E Bradley; Luu, Quang

    2016-10-01

    Cerebrospinal fluid (CSF) leak occurs from traumatic, iatrogenic, and idiopathic etiologies. Its timely diagnosis requires clinical, radiographic, and laboratory testing. Medical and surgical management can mitigate the risk of life-threatening infection and morbidity. This article outlines the pathophysiology, diagnosis, and management or CSF leak of the anterior skull base. PMID:27648397

  15. Commercial Grade Item (CGI) Dedication for Leak Detection Relays

    SciTech Connect

    KOCH, M.R.; JOHNS, B.R.

    1999-12-21

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.

  16. Commercial Grade Item (CGI) Dedication for Leak Detection Relays

    SciTech Connect

    JOHNS, B.R.

    1999-05-05

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.

  17. Commercial Grade Item (CGI) Dedication for Leak Detection Relays

    SciTech Connect

    KOCH, M.R.

    2000-02-28

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.

  18. Pressure Change Measurement Leak Testing Errors

    SciTech Connect

    Pryor, Jeff M; Walker, William C

    2014-01-01

    A pressure change test is a common leak testing method used in construction and Non-Destructive Examination (NDE). The test is known as being a fast, simple, and easy to apply evaluation method. While this method may be fairly quick to conduct and require simple instrumentation, the engineering behind this type of test is more complex than is apparent on the surface. This paper intends to discuss some of the more common errors made during the application of a pressure change test and give the test engineer insight into how to correctly compensate for these factors. The principals discussed here apply to ideal gases such as air or other monoatomic or diatomic gasses; however these same principals can be applied to polyatomic gasses or liquid flow rate with altered formula specific to those types of tests using the same methodology.

  19. Tank 241-SX-115 Leak Assessment

    SciTech Connect

    Not Available

    1992-11-01

    Tank 241-SX-115 (SX-115) is one of 149 underground single-shell tanks (SST) used for the storage of radioactive wastes at the Hanford Site near Richland, Washington. The status of Tank SX-115 today is Interim Stabilized/Interim Isolated. It contains approximately 12,000 gal of dry sludge (no interstitial liquid). Tank SX-115 was built in 1953-1954 and was put into service on August 31, 1958. In March 1965 Tank SX-115 was found to have leaked about 50,000 gal of nitrate solution into the sediments beneath the tank. The remaining solution was pumped to another tank, a small air purge was introduced, and the nearly empty tank was allowed to dry through self-heating. In August 1965 10 test wells were drilled around the tank. Data from these wells and from the already existing drywells and materials were used in earlier studies to define and characterize the contaminated area under the tank. About 60% the leaked material was accounted for. It appears possible that part of the 40% not accounted for may have penetrated deeper into the sediments below the tank. Evidence to support this inference is the relatively high level of radioactivity in Lateral 3 that persisted from 1969 through 1987. If it is necessary to confirm this and to fully define the extent of contamination before final plans for remediation are made, core drilling at an angle under the tank will be required. Radionuclides remaining in the leakage plume as of January 1, 1992, are approximately 21,000 Ci, almost all of it {sup 137}Cs.

  20. Reactor safety research section probability of heat exchanger leaks

    SciTech Connect

    Cramer, D.S.; Shine, E.P.; Copeland, W.J.

    1992-02-01

    Three heat exchangers (HXs) were changed out after the December 1991 leak of Process Water to the Savannah River. This leaves 6 of the original 304 stainless steel heat exchangers which will remain in K-Reactor for restart. This report discusses SRS site specific data which were used to estimate the probability of a leak within a one-year period as a function of leak rate and root cause in these six heat exchangers in conjunction with six new heat exchangers presently in service in K-Reactor. Based on several assumptions and statistical models, SRS data indicate that the total probability of a leak occurring during a one-year period in K-Reactor with 6 original (304 stainless steel) and 6 new (316-L or SEA-CURE) heat exchangers, with a leak rate greater than 20, 40 or 90 pounds/hr, is 0.013, 0.004 or 0.0005, respectively.

  1. Transcatheter closure of paravalvular leaks using a paravalvular leak device – a prospective Polish registry

    PubMed Central

    Pysz, Piotr; Kozłowski, Michał; Jasiński, Marek; Gocoł, Radosław; Roleder, Tomasz; Kargul, Agnieszka; Ochała, Andrzej; Wojakowski, Wojciech

    2016-01-01

    Introduction Transcatheter paravalvular leak closure (TPVLC) has become an established treatment option but is mostly performed with off-label use of different non-dedicated occluders. The first one specifically designed for TPVLC is the paravalvular leak device (PLD – Occlutech). Aim We present initial short-term results of a prospective registry intended to assess the safety and efficacy of TPVLC with PLD. Material and methods We screened patients with paravalvular leak (PVL) after surgical valve replacement (SVR). Heart failure symptoms and/or hemolytic anemia were indications for TPVLC. Patients were selected according to PVL anatomy by RT 3D TEE. Only those considered appropriate for closure with a single PLD were enrolled. The procedures were performed via transvascular or transapical access using type W (waist) PLDs only. Results Thirty patients with 34 PVLs (18 aortic, 16 mitral) were included. We implanted 35 PLDs with a total device success rate of 94.3% (100% for aortic, 88.2% for mitral). The procedural success rate, encompassing device success without in-hospital complications, was 94.1% (100% for aortic, 93.8% for mitral). During the follow-up period we recorded an increase of hemoglobin concentration (3.9 to 4.1 g/dl), red blood count (11.6 to 12.2 M/mm3) and functional improvement by NYHA class. Conclusions Paravalvular leak device type W is a promising TPVLC device, but meticulous preselection of patients based on imaging of PVL anatomy is a prerequisite. A PLD should only be chosen for channels shorter than 5 mm. Size of the device should match the PVL cross-sectional area without any oversizing. Such an approach facilitates high device and procedural success rates. PMID:27279872

  2. 105 K-West isolation barrier leak recovery plan

    SciTech Connect

    Wiborg, J.C.

    1995-03-02

    Leak testing is being performed in 105 KW to verify the performance of the isolation barriers which have been recently installed. When an 11 inch differential head is established between the main basin and the discharge chute, a leak-rate of approximately 30 - 35 gpm is observed. The leak-rate would be achieved by a 1.65`` - 2`` diameter hole (or equivalent). Analyses suggest that the flow is turbulent/laminar transitional (dominantly turbulent), which would be indicative of a single point leak, typical of a pipe or large opening. However, local vortex rotation is observed in the entry to the West transfer chute while no observable motion was seen in the East transfer chute: this may be an indication of seal leakage in the East isolation barrier. The potential for leakage had been considered during the design and field work planning stages. Review of potential leak detection technologies had been made; at the planning stage it was determined that location specific leak detection could be established relatively quickly, applying existing K Basins technology (dye or ultrasonics). The decision was made not to pre-stage leak detection since the equipment development is highly dependent on the nature and location of the leak, and the characteristics of the leak rate provides data which guides leak characterization technology. The expense could be deferred and potentially avoided without risk to critical path activity. Consistent with the above, a systematic recovery plan has been developed utilizing phased activities to provide for management discipline combined with timely diagnosis and correction. Because this activity is not critical path at this time, activities will be coordinated with other plant activity to optimize overall plant work. Particular care will be exercised in assuring that information gained from this recovery can be utilized in the more critical work in 105 KE.

  3. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    NASA Technical Reports Server (NTRS)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge

  4. Leak testing of cryogenic components — problems and solutions

    NASA Astrophysics Data System (ADS)

    Srivastava, S. P.; Pandarkar, S. P.; Unni, T. G.; Sinha, A. K.; Mahajan, K.; Suthar, R. L.

    2008-05-01

    A prototype of Cold Neutron Source (CNS) for Dhruva Reactor is being manufactured at Centre for Design and Manufacture (CDM), BARC, Mumbai for validating the mechanical and thermal engineering design aspects, besides checking the integrity of all joints and components at low temperature, 77K. Task of a Cold Neutron Source is to generate cold neutrons by cooling down the thermal neutrons, which are originally produced in a nuclear research reactor. The complete Cold Neutron Source system comprises a complex arrangement of moderator pot, transfer line (piping), pumps, refrigerators, storage tanks, a heat exchanger and associated controls and instrumentation. The heart of the system is moderator pot in which water (moderator) is cooled down by Liquid Nitrogen (LN2) being circulated through an annular cavity machined on the walls of the pot. Transfer lines for LN2 basically consist of two concentric Stainless Steel flexible pipes, which are joined to the inlet and outlet Aluminium tubes of the moderator pot through transition joints. Leak in any component may result in loss of liquid Nitrogen, degradation of vacuum, which in turn may affect the heat removal efficiency of the source. Hence, leak testing was considered a very important quality control tool and all joints and components were subjected to helium leak test using mass spectrometer leak detector (MSLD) at cryogenic temperature. During one of the earlier experiments, flow of LN2 through inner flexible pipe of the transfer line resulted in rise of pressure in the vacuum annulus and sweating on the outer flexible pipe. After investigations it was found that large thermal stress compounded with mechanical stress resulted in cracks in the inner pipe. Accordingly design was modified to get leak proof transfer line assembly. Further, during leak testing of thin wall moderator pot, gross leak was observed on the outer jacket welded joint. Leak was so large that even a small amount of Helium gas in the vicinity of the

  5. Resilience to Leaking — Dynamic Systems Modeling of Information Security

    PubMed Central

    Hamacher, Kay

    2012-01-01

    Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack ‘unjust’ systems or ‘conspiracies’. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for ‘just’ and ‘unjust’ entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the ‘conspiracy’). In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean’ in direct adversary relations, but do not necessarily increase public benefit and societal immunization to ‘conspiracies’. Furthermore, within the model the exploitation of the (open) competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here. PMID:23227151

  6. Resilience to leaking--dynamic systems modeling of information security.

    PubMed

    Hamacher, Kay

    2012-01-01

    Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack 'unjust' systems or 'conspiracies'. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for 'just' and 'unjust' entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the 'conspiracy'). In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean' in direct adversary relations, but do not necessarily increase public benefit and societal immunization to 'conspiracies'. Furthermore, within the model the exploitation of the (open) competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here. PMID:23227151

  7. Autogenous Metallic Pipe Leak Repair in Potable Water Systems.

    PubMed

    Tang, Min; Triantafyllidou, Simoni; Edwards, Marc A

    2015-07-21

    Copper and iron pipes have a remarkable capability for autogenous repair (self-repair) of leaks in potable water systems. Field studies revealed exemplars that metallic pipe leaks caused by nails, rocks, and erosion corrosion autogenously repaired, as confirmed in the laboratory experiments. This work demonstrated that 100% (N = 26) of 150 μm leaks contacting representative bulk potable water in copper pipes sealed autogenously via formation of corrosion precipitates at 20-40 psi, pH 3.0-11.0, and with upward and downward leak orientations. Similar leaks in carbon steel pipes at 20 psi self-repaired at pH 5.5 and 8.5, but two leaks did not self-repair permanently at pH 11.0 suggesting that water chemistry may control the durability of materials that seal the leaks and therefore the permanence of repair. Larger 400 μm holes in copper pipes had much lower (0-33%) success of self-repair at pH 3.0-11.0, whereas all 400 μm holes in carbon steel pipes at 20 psi self-repaired at pH 4.0-11.0. Pressure tests indicated that some of the repairs created at 20-40 psi ambient pressure could withstand more than 100 psi without failure. Autogenous repair has implications for understanding patterns of pipe failures, extending the lifetime of decaying infrastructure, and developing new plumbing materials.

  8. Endoscopic therapies for leaks and fistulas after bariatric surgery.

    PubMed

    Bhayani, Neil H; Swanström, Lee L

    2014-02-01

    Bariatric surgery is the most effective treatment for the medical comorbidities associated with morbid obesity. Though uncommon, staple line or anastomotic leaks after bariatric surgery are highly morbid events and challenging to treat. In selected patients without severe sepsis or distant pollution, endoscopic transluminal peritoneal drainage may provide source control. For leaks within 3 days of surgery, endoscopic stenting does not appear to speed closure but does permit oral nutrition. In uncomplicated situations, the risk of migration and resulting complications of enteric stents appear to overshadow the benefits. Initial treatment failures and leaks presenting more than 48 hours after surgery respond to enteric diversion by endoscopic stenting. Occlusion of the leak by injection of fibrin glue also shows promise; however, these case series are limited to a small number of patients. Endoclips may work best to occlude leaks and close fistulas if the epithelium is debrided. As suturing technology improves, direct internal closure of fistulas may prove feasible. Therapeutic endoscopy offers several technologies that can assist in the closure of early leaks and that are essential to the treatment of late leaks and fistulas after bariatric surgery.

  9. Management of low colorectal anastomotic leak: Preserving the anastomosis.

    PubMed

    Blumetti, Jennifer; Abcarian, Herand

    2015-12-27

    Anastomotic leak continues to be a dreaded complication after colorectal surgery, especially in the low colorectal or coloanal anastomosis. However, there has been no consensus on the management of the low colorectal anastomotic leak. Currently operative procedures are reserved for patients with frank purulent or feculent peritonitis and unstable vital signs, and vary from simple fecal diversion with drainage to resection of the anastomosis and closure of the rectal stump with end colostomy (Hartmann's procedure). However, if the patient is stable, and the leak is identified days or even weeks postoperatively, less aggressive therapeutic measures may result in healing of the leak and salvage of the anastomosis. Advances in diagnosis and treatment of pelvic collections with percutaneous treatments, and newer methods of endoscopic therapies for the acutely leaking anastomosis, such as use of the endosponge, stents or clips, have greatly reduced the need for surgical intervention in selected cases. Diverting ileostomy, if not already in place, may be considered to reduce fecal contamination. For subclinical leaks or those that persist after the initial surgery, endoluminal approaches such as injection of fibrin sealant, use of endoscopic clips, or transanal closure of the very low anastomosis may be utilized. These newer techniques have variable success rates and must be individualized to the patient, with the goal of treatment being restoration of gastrointestinal continuity and healing of the anastomosis. A review of the treatment of low colorectal anastomotic leaks is presented.

  10. Performance of dust respirators with facial seal leaks. I. Experimental

    SciTech Connect

    Hinds, W.C.; Kraske, G.

    1987-10-01

    The ability of representative half-mask and single-use respirators with facial seal leaks to provide protection against aerosols was evaluated by experimental measurement. Respirators were mounted on a manikin in a test chamber and operated at seven steady flow rates over the range of 2 to 150 L/min. Samples of polydisperse and monodisperse aerosols were taken from inside and outside the respirator and analyzed by a calibrated optical particle counter over the particle-size range 0.1 to 11.3 ..mu..m. Measurements were made separately for filter performance as a function of particle size and flow rate, and simulated leak performance as a function of particle size, pressure drop, and leak size. Flow rate vs. pressure drop measurements were made for all filters and leaks tested. For a given leak condition the percentage of the total flow traversing the leak varied several fold over the usual range of airflow rates through a respirator. Aerosol penetration was found to depend strongly on particle size and flow rate for filters, and to depend strongly on particle size and less strongly on pressure drop for leaks. One can conclude from these measurements that the aerosol-size distribution inside a respirator will nearly always be significantly different from that outside the respirator.

  11. Leak Path Development in CO2 Wells

    NASA Astrophysics Data System (ADS)

    Torsater, M.; Todorovic, J.; Opedal, N.; Lavrov, A.

    2014-12-01

    Wells have in numerous scientific works been denoted the "weak link" of safe and cost-efficient CO2 Capture and Storage (CCS). Whether they are active or abandoned, all wells are man-made intrusions into the storage reservoir with sealing abilities depending on degradable materials like steel and cement. If dense CO2 is allowed to expand (e.g. due to leakage) it will cool down its surroundings and cause strong thermal and mechanical loading on the wellbore. In addition, CO2 reacts chemically with rock, cement and steel. To ensure long-term underground containment, it is therefore necessary to study how, why, where and when leakage occurs along CO2wells. If cement bonding to rock or casing is poor, leak paths can form already during drilling and completion of the well. In the present work, we have mapped the bonding quality of cement-rock and cement-steel interfaces - and measured their resistance towards CO2 flow. This involved a large experimental matrix including different rocks, steels, cement types and well fluids. The bonding qualities were measured on composite cores using micro computed tomography (µ-CT), and CO2 was flooded through the samples to determine leakage rates. These were further compared to numerical simulations of leakage through the digitalized µ-CT core data, and CO2chemical interactions with the materials were mapped using electron microscopy. We also present a new laboratory set-up for measuring how well integrity is affected by downhole temperature variations - and we showcase some initial results. Our work concludes that leak path development in CO2 wells depends critically on the drilling fluids and presflushes/spacers chosen already during drilling and completion of a well. Fluid films residing on rock and casing surfaces strongly degrade the quality of cement bonding. The operation of the well is also important, as even slight thermal cycling (between 10°C and 95°C on casing) leads to significant de-bonding of the annular cement.

  12. Mass-Flow-Meter Leak-Testing System

    NASA Technical Reports Server (NTRS)

    Sorensen, Eric B.; Polidori, Andre V.; Heman, Joe R.; Dresser, Holland L.; Hellum, John

    1996-01-01

    Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

  13. Leak detection system upgrades Cochin pipeline

    SciTech Connect

    Wray, B.; O`Leary, C.

    1996-02-01

    Amoco Canada`s Cochin pipeline system consists of 1,900 miles of 12-inch pipeline, 31 pump stations, eight injection/delivery stations and five propane terminals. It originates just northeast of Edmonton and crosses into the US in North Dakota, runs south of Lake Michigan, turns northeast to pass through Detroit and terminates in Sarnia, Ontario. In 1991, it was decided to significantly upgrade facilities for operating the Cochin pipeline. The control center hardware was obsolete, including parts and components no longer available. Also, SCADA and modeling software was no longer supported by outside vendors or consultants and there was only limited in-house support available. The land-based communications system was unreliable and expensive. Goals for the upgrade project included maintaining (improving) reliability and minimizing operating risks. Amoco Canada wanted to ensure reliable operations and support, provide reliable and effective leak detection, establish dependable communications, have the capability to respond to market additions or changes and maintain customer and regulatory confidence. Another important goal was to minimize operating costs. Specifically, methods were sought to minimize power costs, communications expense and support and maintenance expenditures while eliminating non-productive work. This paper reviews the resulting design and performance of this system.

  14. Effects of a documented hydrogen fluoride leak

    SciTech Connect

    Feder, W.A.

    1985-01-01

    At about 6 a.m. on June 19, 1984, 1037 liters of pressurized HF liquid escaped from a storage tank through a 2 mm diameter hole. 48 hours after the leak was discovered and sealed, visible injury to vegetation was observed 2 miles downwind of the source in a tear drop pattern. Injury symptoms ranged from a slight browning of leaves and needles to death of twigs and leaves and needles. Poplar, white pine, spruce, oak, red maple and several herbaceous plant species were injured. Ragweed was not injured but sensitive fern was severely injured. Goldenrod was also injured but recovered within 3 weeks after exposure. White pine trees within 1/4 of a mile from the source were killed. Fluoride analysis of tissues from upwind and downwind trees and herbaceous plants revealed fluoride tissue levels ranging from 5 to 34,000 ppm. Examples of distance/concentration are given. Soils revealed fluoride levels of about 1 ppm at all locations.

  15. Compact Instruments Measure Helium-Leak Rates

    NASA Technical Reports Server (NTRS)

    Stout, Stephen; Immer, Christopher

    2003-01-01

    Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.

  16. Sodium leak channel, non-selective contributes to the leak current in human myometrial smooth muscle cells from pregnant women.

    PubMed

    Reinl, Erin L; Cabeza, Rafael; Gregory, Ismail A; Cahill, Alison G; England, Sarah K

    2015-10-01

    Uterine contractions are tightly regulated by the electrical activity of myometrial smooth muscle cells (MSMCs). These cells require a depolarizing current to initiate Ca(2+) influx and induce contraction. Cationic leak channels, which permit a steady flow of cations into a cell, are known to cause membrane depolarization in many tissue types. Previously, a Gd(3+)-sensitive, Na(+)-dependent leak current was identified in the rat myometrium, but the presence of such a current in human MSMCs and the specific ion channel conducting this current was unknown. Here, we report the presence of a Na(+)-dependent leak current in human myometrium and demonstrate that the Na(+)-leak channel, NALCN, contributes to this current. We performed whole-cell voltage-clamp on fresh and cultured MSMCs from uterine biopsies of term, non-laboring women and isolated the leak currents by using Ca(2+) and K(+) channel blockers in the bath solution. Ohmic leak currents were identified in freshly isolated and cultured MSMCs with normalized conductances of 14.6 pS/pF and 10.0 pS/pF, respectively. The myometrial leak current was significantly reduced (P < 0.01) by treating cells with 10 μM Gd(3+) or by superfusing the cells with a Na(+)-free extracellular solution. Reverse transcriptase PCR and immunoblot analysis of uterine biopsies from term, non-laboring women revealed NALCN messenger RNA and protein expression in the myometrium. Notably, ∼90% knockdown of NALCN protein expression with lentivirus-delivered shRNA reduced the Gd(3+)-sensitive leak current density by 42% (P < 0.05). Our results reveal that NALCN, in part, generates the leak current in MSMCs and provide the basis for future research assessing NALCN as a potential molecular target for modulating uterine excitability.

  17. Sodium leak channel, non-selective contributes to the leak current in human myometrial smooth muscle cells from pregnant women

    PubMed Central

    Reinl, Erin L.; Cabeza, Rafael; Gregory, Ismail A.; Cahill, Alison G.; England, Sarah K.

    2015-01-01

    Uterine contractions are tightly regulated by the electrical activity of myometrial smooth muscle cells (MSMCs). These cells require a depolarizing current to initiate Ca2+ influx and induce contraction. Cationic leak channels, which permit a steady flow of cations into a cell, are known to cause membrane depolarization in many tissue types. Previously, a Gd3+-sensitive, Na+-dependent leak current was identified in the rat myometrium, but the presence of such a current in human MSMCs and the specific ion channel conducting this current was unknown. Here, we report the presence of a Na+-dependent leak current in human myometrium and demonstrate that the Na+-leak channel, NALCN, contributes to this current. We performed whole-cell voltage-clamp on fresh and cultured MSMCs from uterine biopsies of term, non-laboring women and isolated the leak currents by using Ca2+ and K+ channel blockers in the bath solution. Ohmic leak currents were identified in freshly isolated and cultured MSMCs with normalized conductances of 14.6 pS/pF and 10.0 pS/pF, respectively. The myometrial leak current was significantly reduced (P < 0.01) by treating cells with 10 μM Gd3+ or by superfusing the cells with a Na+-free extracellular solution. Reverse transcriptase PCR and immunoblot analysis of uterine biopsies from term, non-laboring women revealed NALCN messenger RNA and protein expression in the myometrium. Notably, ∼90% knockdown of NALCN protein expression with lentivirus-delivered shRNA reduced the Gd3+-sensitive leak current density by 42% (P < 0.05). Our results reveal that NALCN, in part, generates the leak current in MSMCs and provide the basis for future research assessing NALCN as a potential molecular target for modulating uterine excitability. PMID:26134120

  18. An ultrasonic array sensor for spacecraft leak direction finding.

    PubMed

    Holland, Stephen D; Roberts, Ron; Chimenti, D E; Song, Jun Ho

    2006-12-01

    We have developed an ultrasonic array sensor useable for locating air leaks in manned spacecraft and have found that this sensor locates leaks in a 1-m(2) plate to within 2 cm. The sensor consists of a 63-element multiplexed array plus a reference element, all constructed from a single PZT disc and a printed circuit board. Cross-correlations of signals from the array elements with signals from the single reference element provide a measurement of the leak noise passing through the spacecraft skin under the array. A spatial Fourier transform reveals the dominant direction of propagation. Triangulation from multiple sensor locations can be used to find the source of the leak.

  19. Minimally Invasive, Nonsurgical Approach to Repairing Mitral Valve Leaks

    MedlinePlus

    Minimally Invasive, Nonsurgical Approach to Repairing Mitral Valve Leaks - David X. Zhao, MD Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2016 BroadcastMed, Inc. All rights reserved.

  20. Offsite Radiological Consequence Analysis for the Waste Transfer Leak

    SciTech Connect

    ZIMMERMAN, B.D.

    2003-10-15

    This document quantifies the offsite radiological consequence of the bounding waste transfer leak accident for comparison with the 25 rem Evaluation Guideline established in DOE-STD-3009, Appendix A. The bounding waste transfer leak accident is a large pipe break into a pit. The calculation offsite dose does not challenge the Evaluation Guidelines. Revision 2 incorporated comments received from the office of River Protection. The purpose of this calculation note is to document calculations performed in support of the evaluation of the bounding representative accident scenario for the waste transfer leak accident. The waste transfer leak accident has two representative accident scenarios: the fine spray into the air scenario and the large pipe break into a pit scenario. Both of these scenarios are evaluated in this calculation note, and a determination is made that the large pipe break into a pit scenario is bounding. Only the offsite radiological consequences are considered by this calculation note.

  1. Clinical challenges of persistent pulmonary air-leaks--case report.

    PubMed

    van Zeller, M; Bastos, P; Fernandes, G; Magalhães, A

    2014-01-01

    Air leaks are a common problem after pulmonary resection and can be a source of significant morbidity and mortality. The authors describe the case of a 68-year-old male patient who presented with a persistent air-leak after pulmonary resection. Watchful waiting, surgical procedures, as well as medical therapy like pleurodesis and implantation of endobronchial one-way valves on the bronchial segments identified using systematic occlusion of the bronchial segments, were all tried unsuccessfully. During that time the patient remained hospitalized with a chest tube. The instillation of methylene blue through the chest tube was used to identify the segments leading to the persistent air-leak; this enabled successful endobronchial valve placement which sufficiently reduced the size of the air-leak so that the chest tube could be removed. Nonsurgical approaches seem promising and, for some patients may be the only treatment option after all conventional treatments have failed or are considered too high risk.

  2. Leaks to the Press as Communication within and between Organizations.

    ERIC Educational Resources Information Center

    Kielbowicz, Richard B.

    1980-01-01

    Examines news leaks--the calculated release of information by anonymous officials--as a means by which the mass media have been annexed to perform some of the functions of organizational and interorganizational communication. (RL)

  3. Nutritional management in chyle leaks and chylous effusions.

    PubMed

    Bibby, Anna C; Maskell, Nick A

    2014-10-01

    Chyle leaks occur when there is interruption to the lymphatic ducts that transport chyle around the body. The loss of this protein-rich, calorie-rich fluid can cause serious complications including dehydration, malnutrition and immunosuppression. Treatment of chyle leaks depends on the underlying cause, which may be surgical, secondary to malignant invasion or the result of a medical condition. Nutritional support is vital and leads to spontaneous leak closure in many cases. Nutritional management options include total bowel rest with parenteral nutrition, enteral feeding with specialized formula, or oral diet with supplementation. At present there is no consensus regarding which approach is superior. In reality, most patients with chyle leaks are managed with a combination or oral and enteral feeding, but further work is needed to clarify the optimum management strategy.

  4. 10 CFR 36.59 - Detection of leaking sources.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... leakage at intervals not to exceed 6 months using a leak test kit or method approved by the Commission or... appropriate concentration in table 2, column 2, appendix B to part 20. (See 10 CFR 30.50 for...

  5. Isolation of persistent air leaks and placement of intrabronchial valves

    PubMed Central

    Mahajan, Amit K.; Doeing, Diana C.; Hogarth, Douglas K.

    2013-01-01

    Objectives Alveolar-pleural fistulas causing persistent air leaks are conditions associated with prolonged hospital courses, high morbidity, and possibly increased mortality. Intrabronchial valves serve as a noninvasive therapeutic option for the closure of alveolar-pleural fistulas. Methods The present review describes a brief history of, and indications for, the placement of intrabronchial valves in patients with persistent air leaks. The essential steps necessary for placement are air leak isolation, airway sizing, and valve deployment. Additionally, the indications and methods for intrabronchial valve removal, along with the potential complications from intrabronchial valve placement, are described. Conclusions The increased use of intrabronchial valves in the treatment of persistent air leaks requires bronchoscopists and clinicians to understand the procedural steps and techniques necessary for intrabronchial valve placement. PMID:23312104

  6. Method and device for detecting leaks from pipelines

    SciTech Connect

    Murphy, R.J.

    1983-05-31

    To detect leaks from pipelines carrying fluids, especially oil, light is transmitted through a fibre-optic held in proximity with the pipeline. The fibre-optic is surrounded by a medium of which the refractive index is altered by the influence of the leaked fluid. In a preferred embodiment the medium is a silicone rubber (4) of which the refractive index is normally lower than that of a quartz fibre optic (3), but of which the index increases to that of the quartz or above when oil (7) soaks into it through a permeable cladding (1) and elastomeric protective layer (2), thus rendering the fibre optic non-internally-reflective so that light (6) is absorbed. Control means linked to a light receiver detect that change and the position of the leak is located to within the length of the optic. In another embodiment the medium is a liquid which is expelled from around the optic by the action of leaked fluid.

  7. Inservice leak testing of primary pressure isolation valves

    SciTech Connect

    Livingston, R.A.

    1983-02-01

    This report discusses the inservice leak testing of primary pressure isolation valves in commercial power reactors which was investigated to identify problems with current test procedures and requirements. Nine utilities were surveyed to gather information which is presented in this report. An analysis of the survey information was performed, resulting in recommended changes to improve valve leak testing requirements currently invoked by Section XI of the ASME Boiler and Pressure Vessel Code, Plant Technical Specifications, and Regulatory Guides addressing this subject.

  8. Offsite Radiological Consequence Analysis for the Waste Transfer Leak

    SciTech Connect

    ZIMMERMAN, B.D.

    2003-07-30

    This document quantifies the offsite radiological consequence of the bounding waste transfer leak accident for comparison with the 25 rem Evaluation Guideline established in DOE-STD-3009, Appendix A. The bounding waste transfer leak accident is a large pipe break into a pit. The calculated offsite dose does not challenge the Evaluation Guidelines. Revision 1 incorporates comments received from the Office of River Protection.

  9. Identification of sewage leaks by active remote-sensing methods

    NASA Astrophysics Data System (ADS)

    Goldshleger, Naftaly; Basson, Uri

    2016-04-01

    The increasing length of sewage pipelines, and concomitant risk of leaks due to urban and industrial growth and development is exposing the surrounding land to contamination risk and environmental harm. It is therefore important to locate such leaks in a timely manner, to minimize the damage. Advances in active remote sensing Ground Penetrating Radar (GPR) and Frequency Domain Electromagnetic (FDEM) technologies was used to identify leaking potentially responsible for pollution and to identify minor spills before they cause widespread damage. This study focused on the development of these electromagnetic methods to replace conventional acoustic methods for the identification of leaks along sewage pipes. Electromagnetic methods provide an additional advantage in that they allow mapping of the fluid-transport system in the subsurface. Leak-detection systems using GPR and FDEM are not limited to large amounts of water, but enable detecting leaks of tens of liters per hour, because they can locate increases in environmental moisture content of only a few percentage along the pipes. The importance and uniqueness of this research lies in the development of practical tools to provide a snapshot and monitoring of the spatial changes in soil moisture content up to depths of about 3-4 m, in open and paved areas, at relatively low cost, in real time or close to real time. Spatial measurements performed using GPR and FDEM systems allow monitoring many tens of thousands of measurement points per hectare, thus providing a picture of the spatial situation along pipelines and the surrounding. The main purpose of this study was to develop a method for detecting sewage leaks using the above-proposed geophysical methods, since their contaminants can severely affect public health. We focused on identifying, locating and characterizing such leaks in sewage pipes in residential and industrial areas.

  10. Endoscopic Treatment of Gastrointestinal Perforations, Leaks, and Fistulae.

    PubMed

    Rustagi, Tarun; McCarty, Thomas R; Aslanian, Harry R

    2015-01-01

    Gastrointestinal leaks and fistulae are common postoperative complications, whereas intestinal perforation more commonly complicates advanced endoscopic procedures. Although these complications have classically been managed surgically, there exists an ever-expanding role for endoscopic therapy and the involvement of advanced endoscopists as part of a multidisciplinary team including surgeons and interventional radiologists. This review will serve to highlight the innovative endoscopic interventions that provide an expanding range of viable endoscopic approaches to the management and therapy of gastrointestinal perforation, leaks, and fistulae.

  11. SSME propellant path leak detection real-time

    NASA Technical Reports Server (NTRS)

    Crawford, R. A.; Smith, L. M.

    1994-01-01

    Included are four documents that outline the technical aspects of the research performed on NASA Grant NAG8-140: 'A System for Sequential Step Detection with Application to Video Image Processing'; 'Leak Detection from the SSME Using Sequential Image Processing'; 'Digital Image Processor Specifications for Real-Time SSME Leak Detection'; and 'A Color Change Detection System for Video Signals with Applications to Spectral Analysis of Rocket Engine Plumes'.

  12. Measurement of Submerged Oil/Gas Leaks using ROV Video

    NASA Astrophysics Data System (ADS)

    Shaffer, Franklin; de Vera, Giorgio; Lee, Kenneth; Savas, Ömer

    2013-11-01

    Drilling for oil or gas in the Gulf of Mexico is increasing rapidly at depths up to three miles. The National Commission on the Deepwater Horizon Oil Leak concluded that inaccurate estimates of the leak rate from the Deepwater Horizon caused an inadequate response and attempts to cap the leak to fail. The first response to a submerged oil/gas leak will be to send a Remotely Operated Vehicle (ROV) down to view the leak. During the response to the Deepwater Horizon crisis, the authors Savas and Shaffer were members of the Flow Rate Technical Group's Plume Team who used ROV video to develop the FRTG's first official estimates of the oil leak rate. Savas and Shaffer developed an approach using the larger, faster jet features (e.g., turbulent eddies, vortices, entrained particles) in the near-field developing zone to measure discharge rates. The authors have since used the Berkeley Tow Tank to test this approach on submerged dye-colored water jets and compressed air jets. Image Correlation Velocimetry has been applied to measure the velocity of visible features. Results from tests in the Berkeley Tow Tank and submerged oil jets in the OHMSETT facility will be presented.

  13. Hazardous Gas Leak Analysis in the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Barile, Ronald G.

    1991-01-01

    Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.

  14. Local Leak Detection and Health Monitoring of Pressurized Tanks

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2011-01-01

    An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

  15. Leak test fixture and method for using same

    DOEpatents

    Hawk, Lawrence S.

    1976-01-01

    A method and apparatus are provided which are especially useful for leak testing seams such as an end closure or joint in an article. The test does not require an enclosed pressurized volume within the article or joint section to be leak checked. A flexible impervious membrane is disposed over an area of the seamed surfaces to be leak checked and sealed around the outer edges. A preselected vacuum is applied through an opening in the membrane to evacuate the area between the membrane and the surface being leak checked to essentially collapse the membrane to conform to the article surface or joined adjacent surfaces. A pressure differential is concentrated at the seam bounded by the membrane and only the seam experiences a pressure differential as air or helium molecules are drawn into the vacuum system through a leak in the seam. A helium detector may be placed in a vacuum exhaust line from the membrane to detect the helium. Alternatively, the vacuum system may be isolated at a preselected pressure and leaks may be detected by a subsequent pressure increase in the vacuum system.

  16. 225-B Pool Cell 5 Liner Leak Investigation

    SciTech Connect

    Rasmussen, J.H., Westinghouse Hanford

    1996-06-07

    This document describes the actions taken to confirm and respond to a very small (0.046 ml/min) leak in the stainless steel liner of Hanford`s Waste Encapsulation and Storage Facility (WESF) storage pool cell 5 in Building 225-B. Manual level measurements confirmed a consistent weekly accumulation of 0.46 liters of water in the leak detection grid sump below the pool cell 5 liner. Video inspections and samples point to the capsule storage pool as the source of the water. The present leak rate corresponds to a decrease of only 0.002 inches per week in the pool cell water level, and consequently does not threaten any catastrophic loss of pool cell shielding and cooling water. The configuration of the pool cell liner, sump system, and associated risers will limit the short-term consequences of even a total liner breach to a loss of 1 inch in pool cell level. The small amount of demineralized pool cell water which has been in contact with the concrete structure is not enough to cause significant structural damage. However, ongoing water-concrete interaction increases. The pool cell leak detection sump instrumentation will be modified to improve monitoring of the leak rate in the future. Weekly manual sump level measurements continue in the interim. Contingency plans are in place to relocate the pool cell 5 capsules if the leak worsens.

  17. 40 CFR 63.1087 - What actions must I take if a leak is detected?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false What actions must I take if a leak is... leak is detected? If a leak is detected, you must comply with the requirements in paragraphs (a) and (b) of this section unless repair is delayed according to § 63.1088. (a) Repair the leak as soon...

  18. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... leaks. 192.717 Section 192.717 Transportation Other Regulations Relating to Transportation (Continued... § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak on a transmission line must be made by— (a) Removing the leak by cutting out and replacing...

  19. 40 CFR 63.1087 - What actions must I take if a leak is detected?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 10 2011-07-01 2011-07-01 false What actions must I take if a leak is... leak is detected? If a leak is detected, you must comply with the requirements in paragraphs (a) and (b) of this section unless repair is delayed according to § 63.1088. (a) Repair the leak as soon...

  20. 40 CFR 63.1087 - What actions must I take if a leak is detected?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false What actions must I take if a leak is... leak is detected? If a leak is detected, you must comply with the requirements in paragraphs (a) and (b) of this section unless repair is delayed according to § 63.1088. (a) Repair the leak as soon...

  1. 40 CFR 63.1087 - What actions must I take if a leak is detected?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 11 2012-07-01 2012-07-01 false What actions must I take if a leak is... leak is detected? If a leak is detected, you must comply with the requirements in paragraphs (a) and (b) of this section unless repair is delayed according to § 63.1088. (a) Repair the leak as soon...

  2. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... leaks. 192.717 Section 192.717 Transportation Other Regulations Relating to Transportation (Continued... § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak on a transmission line must be made by— (a) Removing the leak by cutting out and replacing...

  3. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... leaks. 192.717 Section 192.717 Transportation Other Regulations Relating to Transportation (Continued... § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak on a transmission line must be made by— (a) Removing the leak by cutting out and replacing...

  4. 40 CFR 63.1087 - What actions must I take if a leak is detected?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 11 2013-07-01 2013-07-01 false What actions must I take if a leak is... leak is detected? If a leak is detected, you must comply with the requirements in paragraphs (a) and (b) of this section unless repair is delayed according to § 63.1088. (a) Repair the leak as soon...

  5. Fugitive methane emissions from leak-prone natural gas distribution infrastructure in urban environments.

    PubMed

    Hendrick, Margaret F; Ackley, Robert; Sanaie-Movahed, Bahare; Tang, Xiaojing; Phillips, Nathan G

    2016-06-01

    Fugitive emissions from natural gas systems are the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. and contribute to the risk of explosions in urban environments. Here, we report on a survey of CH4 emissions from 100 natural gas leaks in cast iron distribution mains in Metro Boston, MA. Direct measures of CH4 flux from individual leaks ranged from 4.0 - 2.3 × 10(4) g CH4•day(-1). The distribution of leak size is positively skewed, with 7% of leaks contributing 50% of total CH4 emissions measured. We identify parallels in the skewed distribution of leak size found in downstream systems with midstream and upstream stages of the gas process chain. Fixing 'superemitter' leaks will disproportionately stem greenhouse gas emissions. Fifteen percent of leaks surveyed qualified as potentially explosive (Grade 1), and we found no difference in CH4 flux between Grade 1 leaks and all remaining leaks surveyed (p = 0.24). All leaks must be addressed, as even small leaks cannot be disregarded as 'safely leaking.' Key methodological impediments to quantifying and addressing the impacts of leaking natural gas distribution infrastructure involve inconsistencies in the manner in which gas leaks are defined, detected, and classified. To address this need, we propose a two-part leak classification system that reflects both the safety and climatic impacts of natural gas leaks.

  6. Fugitive methane emissions from leak-prone natural gas distribution infrastructure in urban environments.

    PubMed

    Hendrick, Margaret F; Ackley, Robert; Sanaie-Movahed, Bahare; Tang, Xiaojing; Phillips, Nathan G

    2016-06-01

    Fugitive emissions from natural gas systems are the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. and contribute to the risk of explosions in urban environments. Here, we report on a survey of CH4 emissions from 100 natural gas leaks in cast iron distribution mains in Metro Boston, MA. Direct measures of CH4 flux from individual leaks ranged from 4.0 - 2.3 × 10(4) g CH4•day(-1). The distribution of leak size is positively skewed, with 7% of leaks contributing 50% of total CH4 emissions measured. We identify parallels in the skewed distribution of leak size found in downstream systems with midstream and upstream stages of the gas process chain. Fixing 'superemitter' leaks will disproportionately stem greenhouse gas emissions. Fifteen percent of leaks surveyed qualified as potentially explosive (Grade 1), and we found no difference in CH4 flux between Grade 1 leaks and all remaining leaks surveyed (p = 0.24). All leaks must be addressed, as even small leaks cannot be disregarded as 'safely leaking.' Key methodological impediments to quantifying and addressing the impacts of leaking natural gas distribution infrastructure involve inconsistencies in the manner in which gas leaks are defined, detected, and classified. To address this need, we propose a two-part leak classification system that reflects both the safety and climatic impacts of natural gas leaks. PMID:27023280

  7. 40 CFR 1066.985 - Fuel storage system leak test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Fuel storage system leak test... Refueling Emission Test Procedures for Motor Vehicles § 1066.985 Fuel storage system leak test procedure. (a... significant leaks in your fuel storage system. (b) Measurement principles. Leaks are detected by...

  8. The ISS 2B PVTCS Ammonia Leak: An Operational History

    NASA Technical Reports Server (NTRS)

    Vareha, Anthony

    2014-01-01

    In 2006, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B power channel began leaking ammonia at a rate of approximately 1.5lbm/year (out of a starting approximately 53lbm system ammonia mass). Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity during the STS-134 mission. During this mission the system was topped off with ammonia piped over from a separate thermal control system. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. Without these periodic EVAs to refill the 2B coolant system, the channel would eventually leak enough fluid as to risk pump cavitation and system failure, resulting in the loss of the 2B power channel - the most critical of the Space Station's 8 power channels. In mid-2012, the leak rate increased to approximately 5lbm/year. Once discovered, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to a dormant thermal control system not intended to be utilized as anything other than spare components. The purpose of this rerouting of the TCS was to increase system volume and to isolate the photovoltaic radiator, thought to be the likely leak source. This EVA was successfully executed on November 1st, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a totally different radiator than what the system was designed to utilize. Unfortunately, data monitoring over the next several months showed that the isolated radiator was not leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the

  9. Leak detection by acoustic emissions monitoring: An experimental investigation of the acoustic properties of leaks and the attenuation characteristics of soil

    SciTech Connect

    Kilpatrick, J.F.; March, P.A.

    1994-05-27

    This study experimentally explored the conditions, equipment, and methodology necessary for the acoustic detection of small leaks of jet fuel (JP4) from underground storage tank (UST) systems. The study indicates that acoustic leak detection of very small leaks is feasible. In general, significant JP4 fuel leaks which occur across a 5 PSI (pounds per square inch) or greater pressure drop are acoustically active and can be detected with proper sensors and proper placement of sensors. The primary source of leak noise is turbulent flow through the leak orifice. At lower pressures, the leak flow becomes laminar, and the leak becomes virtually silent. With direct transducer contact on the pipe or tank wall and sufficient system pressure, leaks smaller than 0.1 GPH (gallons per hour) can be detected. Larger leaks can be detected through short distances in soil. However, sand, which is the most commonly used fill material for UST systems, provides significant acoustic attenuation. Consequently, waveguides must be used when monitoring distances exceeding about 1 foot of travel through sand. Sand acts to reduce background noise levels, providing an ideal environment for acoustic leak detection using sensors mounted directly on the pipe or tank wall. Leak detection, Acoustics, Underground storage tanks, Pipelines, Attenuation.

  10. Assessing the Rayleigh Intensity Remote Leak Detection Technique

    NASA Technical Reports Server (NTRS)

    Clements, Sandra

    2001-01-01

    Remote sensing technologies are being considered for efficient, low cost gas leak detection. An exploratory project to identify and evaluate remote sensing technologies for application to gas leak detection is underway. During Phase 1 of the project, completed last year, eleven specific techniques were identified for further study. One of these, the Rayleigh Intensity technique, would make use of changes in the light scattered off of gas molecules to detect and locate a leak. During the 10-week Summer Faculty Fellowship Program, the scatter of light off of gas molecules was investigated. The influence of light scattered off of aerosols suspended in the atmosphere was also examined to determine if this would adversely affect leak detection. Results of this study indicate that in unconditioned air, it will be difficult, though perhaps not impossible, to distinguish between a gas leak and natural variations in the aerosol content of the air. Because information about the particle size distribution in clean room environments is incomplete, the applicability in clean rooms is uncertain though more promising than in unconditioned environments. It is suggested that problems caused by aerosols may be overcome by using the Rayleigh Intensity technique in combination with another remote sensing technique, the Rayleigh Doppler technique.

  11. Apparatus and method for detecting leaks in piping

    DOEpatents

    Trapp, D.J.

    1994-12-27

    A method and device are disclosed for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe. 2 figures.

  12. Apparatus and method for detecting leaks in piping

    DOEpatents

    Trapp, Donald J.

    1994-01-01

    A method and device for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe.

  13. Echocardiographic findings in patients with spontaneous CSF leak.

    PubMed

    Pimienta, Allen L; Rimoin, David L; Pariani, Mitchel; Schievink, Wouter I; Reinstein, Eyal

    2014-10-01

    The presence of cardiovascular abnormalities in patients with spontaneous cerebrospinal fluid (CSF) leaks are not well-documented in the literature, as cardiovascular evaluation is not generally pursued if a patient does not exhibit additional clinical features suggesting an inherited connective tissue disorder. We aimed to assess this association, enrolling a consecutive group of 50 patients referred for spinal CSF leak consultation. Through echocardiographic evaluation and detailed medical history, we estimate that up to 20% of patients presenting with a spontaneous CSF leak may have some type of cardiovascular abnormality. Further, the increase in prevalence of aortic dilatation in our cohort was statistically significant in comparison to the estimated population prevalence. This supports a clinical basis for echocardiographic screening of these individuals for cardiovascular manifestations that may have otherwise gone unnoticed or evolved into a more severe manifestation.

  14. Optimization of the leak conductance in the squid giant axon

    NASA Astrophysics Data System (ADS)

    Seely, Jeffrey; Crotty, Patrick

    2010-08-01

    We report on a theoretical study showing that the leak conductance density, GL , in the squid giant axon appears to be optimal for the action potential firing frequency. More precisely, the standard assumption that the leak current is composed of chloride ions leads to the result that the experimental value for GL is very close to the optimal value in the Hodgkin-Huxley model, which minimizes the absolute refractory period of the action potential, thereby maximizing the maximum firing frequency under stimulation by sharp, brief input current spikes to one end of the axon. The measured value of GL also appears to be close to optimal for the frequency of repetitive firing caused by a constant current input to one end of the axon, especially when temperature variations are taken into account. If, by contrast, the leak current is assumed to be composed of separate voltage-independent sodium and potassium currents, then these optimizations are not observed.

  15. Oil/gas collector/separator for underwater oil leaks

    DOEpatents

    Henning, Carl D.

    1993-01-01

    An oil/gas collector/separator for recovery of oil leaking, for example, from an offshore or underwater oil well. The separator is floated over the point of the leak and tethered in place so as to receive oil/gas floating, or forced under pressure, toward the water surface from either a broken or leaking oil well casing, line, or sunken ship. The separator is provided with a downwardly extending skirt to contain the oil/gas which floats or is forced upward into a dome wherein the gas is separated from the oil/water, with the gas being flared (burned) at the top of the dome, and the oil is separated from water and pumped to a point of use. Since the density of oil is less than that of water it can be easily separated from any water entering the dome.

  16. Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor)

    2015-01-01

    The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

  17. The causes and functions of mitochondrial proton leak.

    PubMed

    Brand, M D; Chien, L F; Ainscow, E K; Rolfe, D F; Porter, R K

    1994-08-30

    The non-linear relationship between respiration rate and protonmotive force in isolated mitochondria is explained entirely by delta p-dependent changes in the proton conductance of the mitochondrial inner membrane and is not caused by redox slip in the proton pumps. Mitochondrial proton leak occurs in intact cells and tissues: the futile cycle of proton pumping and proton leak accounts for 26% +/- 7% of the total oxygen consumption rate or 33% +/- 7% of the mitochondrial respiration rate of isolated hepatocytes (mean +/- S.D. for 43 rats); 52% of the oxygen consumption rate of resting perfused muscle and up to 38% of the basal metabolic rate of a rat, suggesting that heat production may be an important function in the proton leak in homeotherms. Together with non-mitochondrial oxygen consumption, it lowers the effective P/O ratio in cells from maximum possible values of 2.33 (palmitate oxidation) or 2.58 (glucose oxidation) to as low as 1.1 in liver or 0.8 in muscle. The effective P/O ratio increases in response to ATP demand; the ability to allow rapid switching of flux from leak to ATP turnover may be an even more important function of the leak reaction than heat production. The mitochondrial proton conductance in isolated mitochondria and in hepatocytes is greatly modulated by thyroid hormones, by phylogeny and by body mass. Usually the reactions of ATP turnover change in parallel so that the coupling ratio is not greatly affected. Changes in proton leak in tissues are brought about in the short term by changes in mitochondrial protonmotive force and in the longer term by changes in the surface area and proton permeability of the mitochondrial inner membrane. Permeability changes are probably caused by changes in the fatty acid composition of the membrane phospholipids.

  18. High Altitude Aerial Natural Gas Leak Detection System

    SciTech Connect

    Richard T. Wainner; Mickey B. Frish; B. David Green; Matthew C. Laderer; Mark G. Allen; Joseph R. Morency

    2006-12-31

    The objective of this program was to develop and demonstrate a cost-effective and power-efficient advanced standoff sensing technology able to detect and quantify, from a high-altitude (> 10,000 ft) aircraft, natural gas leaking from a high-pressure pipeline. The advanced technology is based on an enhanced version of the Remote Methane Leak Detector (RMLD) platform developed previously by Physical Sciences Inc. (PSI). The RMLD combines a telecommunications-style diode laser, fiber-optic components, and low-cost DSP electronics with the well-understood principles of Wavelength Modulation Spectroscopy (WMS), to indicate the presence of natural gas located between the operator and a topographic target. The transceiver transmits a laser beam onto a topographic target and receives some of the laser light reflected by the target. The controller processes the received light signal to deduce the amount of methane in the laser's path. For use in the airborne platform, we modified three aspects of the RMLD, by: (1) inserting an Erbium-doped optical fiber laser amplifier to increase the transmitted laser power from 10 mW to 5W; (2) increasing the optical receiver diameter from 10 cm to 25 cm; and (3) altering the laser wavelength from 1653 nm to 1618 nm. The modified RMLD system provides a path-integrated methane concentration sensitivity {approx}5000 ppm-m, sufficient to detect the presence of a leak from a high capacity transmission line while discriminating against attenuation by ambient methane. In ground-based simulations of the aerial leak detection scenario, we demonstrated the ability to measure methane leaks within the laser beam path when it illuminates a topographic target 2000 m away. We also demonstrated simulated leak detection from ranges of 200 m using the 25 cm optical receiver without the fiber amplifier.

  19. Leak detection by acoustic emissions monitoring: An experimental investigation of the acoustic properties of leaks and the attenuation characteristics of soil

    NASA Astrophysics Data System (ADS)

    Kilpatrick, James F.; March, Patrick A.

    1994-05-01

    This study experimentally explored the conditions, equipment, and methodology necessary for the acoustic detection of small leaks of jet fuel (JP4) from underground storage tank (UST) systems. The study indicates that acoustic leak detection of very small leaks is feasible. In general, significant JP4 fuel leaks which occur across a 5 PSI (pounds per square inch) or greater pressure drop are acoustically active and can be detected with proper sensors and proper placement of sensors. The primary source of leak noise is turbulent flow through the leak orifice. At lower pressures, the leak flow becomes laminar, and the leak becomes virtually silent. With direct transducer contact on the pipe or tank wall and sufficient system pressure, leaks smaller than 0.1 GPH (gallons per hour) can be detected. Larger leaks can be detected through short distances in soil. However, sand, which is the most commonly used fill material for UST systems, provides significant acoustic attenuation. Consequently, waveguides must be used when monitoring distances exceeding about 1 foot of travel through sand. Sand acts to reduce background noise levels, providing an ideal environment for acoustic leak detection using sensors mounted directly on the pipe or tank wall.

  20. Leak before break application in French PWR plants under operation

    SciTech Connect

    Faidy, C.

    1997-04-01

    Practical applications of the leak-before break concept are presently limited in French Pressurized Water Reactors (PWR) compared to Fast Breeder Reactors. Neithertheless, different fracture mechanic demonstrations have been done on different primary, auxiliary and secondary PWR piping systems based on similar requirements that the American NUREG 1061 specifications. The consequences of the success in different demonstrations are still in discussion to be included in the global safety assessment of the plants, such as the consequences on in-service inspections, leak detection systems, support optimization,.... A large research and development program, realized in different co-operative agreements, completes the general approach.

  1. Apparatus for the remote detection of sounds caused by leaks

    NASA Technical Reports Server (NTRS)

    Shakkottai, Parthasarathy (Inventor); Alwar, Vijayaraghavan (Inventor)

    1990-01-01

    Two laser beams derived from a laser pass through a furnace and are superposed in a laser spot to produce interference fringes having the same pitch as that of a Ronchi grating printed on a retroreflecting screen. Minute fluctuations of the laser beams caused by sound waves from leaks result in intensity fluctuations of the laser spot when the laser fringes move past the fixed grating. A telescope and photocell arrangement detects the light variations to produce an electrical signal which is amplified and filtered to detect the sound of leaks. This non-contact laser Schlieren microphone is sensitive to sounds all along the path of the beams.

  2. External detection and localization of well leaks in aquifer zones

    NASA Astrophysics Data System (ADS)

    Haas, Allan K.

    This dissertation presents a new methodology for monitoring, detecting, and localizing shallow, aquifer zone leaks in oil and gas wells. The rationale for this type of leak detection is to close the knowledge gap associated with public claims of subsurface water resource contamination caused by the oil and gas industry. A knowledge gap exists because there is no data, one way or the other, that can definitively prove or deny the existence of subsurface leakage pathways in oil and gas wells, new, old or abandoned. This dissertation begins with an overview of existing and future oil and gas well leak detection methods, and then presents three published papers, each describing a different phenomena that can be exploited for leak monitoring, detection, localization, and damage extent determination. The first paper describes the direct detection and localization of a leak that was discovered during a laboratory based hydraulic fracturing experiment. The second paper describes the laboratory measured electrical response that occurs during two phase flow inside of porous media. The third paper describes the detection and tracking of a gravity driven salt plume leak in a freshwater test tank in the laboratory. the three geophysical approaches that are presented, when combined together, provide a new, powerful, external to the well method to monitor, detect, localize, and assess the damage from leaks in the drinking water protection zone of oil and gas wells. This is a capability that is not available in any other leak detection and localization method. This dissertation also presents a chapter of Science, Technology and Society (STS), and Science, and Technology Policy (STP) as a final fulfillment requirement of the SmartGeo Fellowship program, and the Science, Technology, Engineering, and Policy minor. This chapter introduces a new STS/STP concept concerning the after effects of knowledge boundary disputes. This new concept is called the residual footprints of knowledge

  3. Wide-band gas leak imaging detection system using UFPA

    NASA Astrophysics Data System (ADS)

    Jin, Wei-qi; Li, Jia-kun; Dun, Xiong; Jin, Minglei; Wang, Xia

    2014-11-01

    The leakage of toxic or hazardous gases not only pollutes the environment, but also threatens people's lives and property safety. Many countries attach great importance to the rapid and effective gas leak detection technology and instrument development. However, the gas leak imaging detection systems currently existing are generally limited to a narrow-band in Medium Wavelength Infrared (MWIR) or Long Wavelength Infrared (LWIR) cooled focal plane imaging, which is difficult to detect the common kinds of the leaking gases. Besides the costly cooled focal plane array is utilized, the application promotion is severely limited. To address this issue, a wide-band gas leak IR imaging detection system using Uncooled Focal Plane Array (UFPA) detector is proposed, which is composed of wide-band IR optical lens, sub-band filters and switching device, wide-band UFPA detector, video processing and system control circuit. A wide-band (3µm~12µm) UFPA detector is obtained by replacing the protection window and optimizing the structural parameters of the detector. A large relative aperture (F#=0.75) wide-band (3μm~12μm) multispectral IR lens is developed by using the focus compensation method, which combining the thickness of the narrow-band filters. The gas leak IR image quality and the detection sensitivity are improved by using the IR image Non-Uniformity Correction (NUC) technology and Digital Detail Enhancement (DDE) technology. The wide-band gas leak IR imaging detection system using UFPA detector takes full advantage of the wide-band (MWIR&LWIR) response characteristic of the UFPA detector and the digital image processing technology to provide the resulting gas leak video easy to be observed for the human eyes. Many kinds of gases, which are not visible to the naked eyes, can be sensitively detected and visualized. The designed system has many commendable advantages, such as scanning a wide range simultaneously, locating the leaking source quickly, visualizing the gas

  4. Minimally invasive management of anastomotic leaks in colorectal surgery

    PubMed Central

    Sevim, Yusuf; Celik, Suleyman Utku; Yavarifar, Hana; Akyol, Cihangir

    2016-01-01

    Anastomotic leakage is an unfortunate complication of colorectal surgery. This distressing situation can cause severe morbidity and significantly affects the patient’s quality of life. Additional interventions may cause further morbidity and mortality. Parenteral nutrition and temporary diverting ostomy are the standard treatments of anastomotic leaks. However, technological developments in minimally invasive treatment modalities for anastomotic dehiscence have caused them to be used widely. These modalities include laparoscopic repair, endoscopic self-expandable metallic stents, endoscopic clips, over the scope clips, endoanal repair and endoanal sponges. The review aimed to provide an overview of the current knowledge on the minimally invasive management of anastomotic leaks. PMID:27721925

  5. Secondary containment and leak detection: A great marriage

    SciTech Connect

    Geyer, W.B.; Stellmach, W.A.

    1995-04-01

    The past decade has seen a proliferation of sophisticated release detection systems for both underground and aboveground storage tanks. But leak detection alone will not ensure against contamination. The storage tank owner who has to spend $100,000 or more to clean up contaminated soil - and much more if groundwater becomes tainted - could have avoided real headaches by investing in sound secondary containment in addition to leak detection. Combined with release detection devices, secondary containment provides the best insurance for UST owners through containment of the primary tank and its piping. We call this a great marriage between two technologies - and EPA agrees.

  6. Endoscopic management of biliary leaks after laparoscopic cholecystectomy.

    PubMed

    Rustagi, Tarun; Aslanian, Harry R

    2014-09-01

    Laparoscopic cholecystectomy has become the procedure of choice for management of symptomatic cholelithiasis. Although it has distinct advantages over open cholecystectomy, bile leak is more common. Endoscopic retrograde cholangiopancreatography is the diagnostic and therapeutic modality of choice for management of postcholecystectomy bile leaks and has a high success rate with the placement of plastic biliary stents. Repeat endoscopic retrograde cholangiopancreatography with placement of multiple plastic stents, a covered metal stent, or possibly cyanoacrylate therapy may be effective in refractory cases. This review will discuss the indications, efficacy, and complications of endoscopic therapy.

  7. Code System to Calculate Reactor Coolant System Leak Rate.

    1999-10-19

    Version 00 RCSLK9 was developed to analyze the leak tightness of the primary coolant system for any pressurized water reactor (PWR). From given system conditions, water levels in tanks, and certain system design parameters, RCSLK9 calculates the loss of water from the reactor coolant system (RCS) and the increase of water in the leakage collection system during an arbitrary time interval. The program determines the system leak rates and displays or prints a report ofmore » the results. During the initial application to a specific reactor, RCSLK9 creates a file of system parameters and saves it for future use.« less

  8. STIS-ACS Red Leak Cross-Calibration

    NASA Astrophysics Data System (ADS)

    Chiaberge, Marco

    2009-07-01

    We observe one type K star {G Gem} with ACS/SBC and STIS in order to determine the throughput in the red leak of both the SBC and the STIS FUV-MAMA. We will also observe the type G9V star HD53143 with the SBC with all long-pass filters and the PR130L in order to compare the observed fluxes and the spectrum with a previous prism observation of the same star and investigate the possible time dependence of the red leak.

  9. A low-cost molecular-leak value

    NASA Technical Reports Server (NTRS)

    Judson, C. M.; Lawrence, J. L., Jr.; Pickett, F. P.

    1980-01-01

    Solenoid operated modular-leak and shutoff valve has been developed for small portable, automated, mass spectrometer used to measure trace constituents of air or other gases. Valve costs much less to produce than precision needle-in-foil type. Yet its performance closely matches that version.

  10. 40 CFR 63.1331 - Equipment leak provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... limited to, a rupture disk indicator, magnetic sensor, motion detector on the pressure relief valve stem... evidence of a potential leak found by visual, audible, or olfactory means. Method 21, 40 CFR part 60... by Method 21 of 40 CFR part 60, appendix A. (v) Indications of liquids dripping, as defined...

  11. 40 CFR 63.1434 - Equipment leak provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... include, but are not limited to, a rupture disk indicator, magnetic sensor, motion detector on the... HON equipment leak requirements in 40 CFR part 63, subpart H for all equipment in organic HAP service... above background as detected by Method 21 of 40 CFR part 60, appendix A. (2) Pressure...

  12. Thermal-leak analyzer for vacuum-jacketed lines

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.; Ruppe, E. P.

    1978-01-01

    Technique involves coating suspected area with water-soluble black paint that gives even, infrared emission. Painted area is warmed with heat gun; an infrared scanner is used to detect cooled spot on jacket exterior. Introduction of atmospheric pressure into jacket intensifies leak jet and improves test sensitivity.

  13. COPPER PITTING CORROSION AND PINHOLE LEAKS: A CASE STUDY

    EPA Science Inventory

    Localized corrosion, or "pitting", of copper drinking water pipe continues is a problem for many water utilities and their customers. Extreme attack leads to pinhole leaks that can potentially lead to water damage, mold growth, and costly repairs for the homeowners, as well as th...

  14. 40 CFR 63.1434 - Equipment leak provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... requirements in 40 CFR part 63, subpart H for all equipment in organic HAP service, except as specified in... contained in §§ 63.182(a)(1) and 63.182(b) are referred to in 40 CFR part 63, subpart H, the owner or... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Equipment leak provisions....

  15. 40 CFR 63.1434 - Equipment leak provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements in 40 CFR part 63, subpart H for all equipment in organic HAP service, except as specified in... contained in § 63.182(a)(1) and § 63.182(b) are referred to in 40 CFR part 63, subpart H, the owner or... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Equipment leak provisions....

  16. DETAIL OF JAMES LEAK CONFEDERATE HEADSTONE (RIGHT FOREGROUND), WITH CANNON, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF JAMES LEAK CONFEDERATE HEADSTONE (RIGHT FOREGROUND), WITH CANNON, FLAGPOLE, CONFEDERATE MONUMENT, CANNONBALL PYRAMID AND ARC OF UNKNOWN U.S. SOLDIER HEADSTONES IN BACKGROUND. VIEW TO NORTHEAST. - Oak Woods Cemetery, Confederate Mound, 1035 East 67th Street, Chicago, Cook County, IL

  17. 40 CFR 63.1434 - Equipment leak provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... requirements in 40 CFR part 63, subpart H for all equipment in organic HAP service, except as specified in... contained in §§ 63.182(a)(1) and 63.182(b) are referred to in 40 CFR part 63, subpart H, the owner or... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Equipment leak provisions....

  18. 84. Photocopied August 1978. REPAIRING FOREBAY LEAK, NOVEMBER 1907. THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    84. Photocopied August 1978. REPAIRING FOREBAY LEAK, NOVEMBER 1907. THE PILE-DRIVER IS DRIVING NEW PILES FOR THE FOREBAY APRON, CLAY BACKFILL AND PLANKING CREWS ARE BUSY AT THE RIGHT. MUCH OF THE FOREBAY FLOOR WAS ALSO REPLANKED AT THIS TIME. (520) - Michigan Lake Superior Power Company, Portage Street, Sault Ste. Marie, Chippewa County, MI

  19. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Leak check test. (a) Overview. In section 7.4.6 of 40 CFR part 50, appendix L, the sampler is required..., NIST-traceable. (2) Flow rate measurement adaptor (40 CFR part 50, appendix L, figure L-30) or... CFR part 50, appendix L. (d) Calibration of test measurement instruments. Submit documentation...

  20. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Leak check test. (a) Overview. In section 7.4.6 of 40 CFR part 50, appendix L, the sampler is required..., NIST-traceable. (2) Flow rate measurement adaptor (40 CFR part 50, appendix L, figure L-30) or... CFR part 50, appendix L. (d) Calibration of test measurement instruments. Submit documentation...

  1. A Hydrazine Leak Sensor Based on Chemically Reactive Thermistors

    NASA Technical Reports Server (NTRS)

    Davis, Dennis D.; Mast, Dion J.; Baker, David L.

    1999-01-01

    Leaks in the hydrazine supply system of the Shuttle APU can result in hydrazine ignition and fire in the aft compartment of the Shuttle. Indication of the location of a leak could provide valuable information required for operational decisions. WSTF has developed a small, single use sensor for detection of hydrazine leaks. The sensor is composed of a thermistor bead coated with copper(II) oxide (CuO) dispersed in a clay or alumina binder. The CuO-coated thermistor is one of a pair of closely located thermistors, the other being a reference. On exposure to hydrazine the CuO reacts exothermically with the hydrazine and increases the temperature of the coated-thermistor by several degrees. The temperature rise is sensed by a resistive bridge circuit and an alarm registered by data acquisition software. Responses of this sensor to humidity changes, hydrazine concentration, binder characteristics, distance from a liquid leak, and ambient pressure levels as well as application of this sensor concept to other fluids are presented.

  2. 40 CFR 63.424 - Standards: Equipment leaks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Standards for Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations) § 63.424 Standards: Equipment leaks. (a) Each owner or operator of a bulk gasoline terminal or pipeline... limited to, the following: (1) Minimize gasoline spills; (2) Clean up spills as expeditiously...

  3. 40 CFR 63.424 - Standards: Equipment leaks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards for Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations) § 63.424 Standards: Equipment leaks. (a) Each owner or operator of a bulk gasoline terminal or pipeline... limited to, the following: (1) Minimize gasoline spills; (2) Clean up spills as expeditiously...

  4. 40 CFR 63.424 - Standards: Equipment leaks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Standards for Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations) § 63.424 Standards: Equipment leaks. (a) Each owner or operator of a bulk gasoline terminal or pipeline... limited to, the following: (1) Minimize gasoline spills; (2) Clean up spills as expeditiously...

  5. 40 CFR 63.424 - Standards: Equipment leaks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Standards for Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations) § 63.424 Standards: Equipment leaks. (a) Each owner or operator of a bulk gasoline terminal or pipeline... limited to, the following: (1) Minimize gasoline spills; (2) Clean up spills as expeditiously...

  6. Analog Binaural Circuits for Detecting and Locating Leaks

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T.

    2003-01-01

    Very-large-scale integrated (VLSI) analog binaural signal-processing circuits have been proposed for use in detecting and locating leaks that emit noise in the ultrasonic frequency range. These circuits would be designed to function even in the presence of intense lower-frequency background noise that could include sounds associated with flow and pumping. Each of the proposed circuits would include the approximate electronic equivalent of a right and a left cochlea plus correlator circuits. A pair of transducers (microphones or accelerometers), corresponding to right and left ears, would provide the inputs to their respective cochleas from different locations (e.g., from different positions along a pipe). The correlation circuits plus some additional external circuits would determine the difference between the times of arrival of a common leak sound at the two transducers. Then the distance along the pipe from either transducer to the leak could be estimated from the time difference and the speed of sound along the pipe. If three or more pairs of transducers and cochlear/correlator circuits were available and could suitably be positioned, it should be possible to locate a leak in three dimensions by use of sound propagating through air.

  7. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Leak check test. (a) Overview. In section 7.4.6 of 40 CFR part 50, appendix L, the sampler is required..., NIST-traceable. (2) Flow rate measurement adaptor (40 CFR part 50, appendix L, figure L-30) or... CFR part 50, appendix L. (d) Calibration of test measurement instruments. Submit documentation...

  8. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Leak check test. (a) Overview. In section 7.4.6 of 40 CFR part 50, appendix L, the sampler is required..., NIST-traceable. (2) Flow rate measurement adaptor (40 CFR part 50, appendix L, figure L-30) or... CFR part 50, appendix L. (d) Calibration of test measurement instruments. Submit documentation...

  9. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Leak check test. (a) Overview. In section 7.4.6 of 40 CFR part 50, appendix L, the sampler is required..., NIST-traceable. (2) Flow rate measurement adaptor (40 CFR part 50, appendix L, figure L-30) or... CFR part 50, appendix L. (d) Calibration of test measurement instruments. Submit documentation...

  10. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME I

    EPA Science Inventory

    A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems whe...

  11. 40 CFR 63.1331 - Equipment leak provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... evidence of a potential leak found by visual, audible, or olfactory means. Method 21, 40 CFR part 60... by Method 21 of 40 CFR part 60, appendix A. (v) Indications of liquids dripping, as defined in... considered. (8) When the provisions of subpart H of this part specify that Method 18, 40 CFR part...

  12. 10 CFR 39.35 - Leak testing of sealed sources.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Leak testing of sealed sources. 39.35 Section 39.35 Energy... frequency. (1) Each sealed source (except an energy compensation source (ECS)) must be tested at intervals... paragraphs (a) through (d) of this section: (1) Hydrogen-3 (tritium) sources; (2) Sources containing...

  13. 10 CFR 39.35 - Leak testing of sealed sources.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Leak testing of sealed sources. 39.35 Section 39.35 Energy... frequency. (1) Each sealed source (except an energy compensation source (ECS)) must be tested at intervals... paragraphs (a) through (d) of this section: (1) Hydrogen-3 (tritium) sources; (2) Sources containing...

  14. 10 CFR 39.35 - Leak testing of sealed sources.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Leak testing of sealed sources. 39.35 Section 39.35 Energy... frequency. (1) Each sealed source (except an energy compensation source (ECS)) must be tested at intervals... paragraphs (a) through (d) of this section: (1) Hydrogen-3 (tritium) sources; (2) Sources containing...

  15. Valve leak detection for maintenance and thermal performance

    SciTech Connect

    Dimmick, J.G.; Mills, W.H.

    1988-01-01

    The theory and practical applications of the acoustic valve leak analyzer (AVLA) are discussed in this paper. Test procedures, analysis techniques, limitations, and results are presented, along with several case histories. It also presents information on check valve applications, which are routine for marine steam plants, but only recently of interest to utility engineers.

  16. Leak detection system and control using non-rigid bladder

    SciTech Connect

    Pillette, K.P.

    1980-11-11

    A portable system for early detection of leaks from suspect piping fittings, for example, as used on the ''christmas tree'' portion of a gas well provides an encapsulating bladder which sealably encapsulates the suspect fitting and collects leaks from the fitting. The apparatus provides, in the preferred embodiment, a bladder which can encase any suspect portion of the christmas tree (Or like piping system), such as for example, the choke jacket or other like fittings where maximum turbulence occurs as when gas or oil mixed with sand flows through the fitting. In the preferred embodiment, the collection of a leak within the bladder causes a regulator to operate a control valve and halt the flow of gas, oil, or like flowing material through the piping system of which the suspect fitting is a part. The system can be applied to any other similar existing and operating piping arrangement where the detection of leaks from suspect fittings is desirable. The portable bladder and shut off arrangement of the present invention has particular application in the offshore oil and gas industry, where it can perform a safety function on unmanned gas/oil well platforms.

  17. 40 CFR 63.1410 - Equipment leak provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the requirements of 40 CFR part 63, subpart UU (national emission standards for equipment leaks... with the requirements of 40 CFR part 63, subpart SS, as referred to by 40 CFR part 63, subpart UU, the...., small control devices). (b) When 40 CFR part 63, subpart SS refers to specific test methods for...

  18. 40 CFR 63.1410 - Equipment leak provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CFR part 63, subpart UU (national emission standards for equipment leaks (control level 2)) for all... of 40 CFR part 63, subpart SS, as referred to by 40 CFR part 63, subpart UU, the following apply for... devices). (b) When 40 CFR part 63, subpart SS refers to specific test methods for the measurement...

  19. 40 CFR 63.1410 - Equipment leak provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CFR part 63, subpart UU (national emission standards for equipment leaks (control level 2)) for all... of 40 CFR part 63, subpart SS, as referred to by 40 CFR part 63, subpart UU, the following apply for... devices). (b) When 40 CFR part 63, subpart SS refers to specific test methods for the measurement...

  20. 40 CFR 63.1410 - Equipment leak provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CFR part 63, subpart UU (national emission standards for equipment leaks (control level 2)) for all... of 40 CFR part 63, subpart SS, as referred to by 40 CFR part 63, subpart UU, the following apply for... devices). (b) When 40 CFR part 63, subpart SS refers to specific test methods for the measurement...

  1. 40 CFR 63.1410 - Equipment leak provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the requirements of 40 CFR part 63, subpart UU (national emission standards for equipment leaks... with the requirements of 40 CFR part 63, subpart SS, as referred to by 40 CFR part 63, subpart UU, the...., small control devices). (b) When 40 CFR part 63, subpart SS refers to specific test methods for...

  2. 40 CFR 63.1255 - Standards: Equipment leaks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... comply only with the provisions of this subpart: (i) 40 CFR part 60. (ii) 40 CFR part 61. (3) (4) The... successful repair of the leak. (iv) The maximum instrument reading measured by Method 21 of 40 CFR part 60...-type scaffold which would allow access to equipment up to 7.6 meters (25 feet) above the ground; or...

  3. 40 CFR 63.1255 - Standards: Equipment leaks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... comply only with the provisions of this subpart: (i) 40 CFR part 60. (ii) 40 CFR part 61. (3) (4) The... successful repair of the leak. (iv) The maximum instrument reading measured by Method 21 of 40 CFR part 60...-type scaffold which would allow access to equipment up to 7.6 meters (25 feet) above the ground; or...

  4. 40 CFR 63.1255 - Standards: Equipment leaks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following will be required to comply only with the provisions of this subpart: (i) 40 CFR part 60. (ii) 40 CFR part 61. (3) (4) The provisions in § 63.1(a)(3) of subpart A of this part do not alter the... successful repair of the leak. (iv) The maximum instrument reading measured by Method 21 of 40 CFR part...

  5. 40 CFR 63.1255 - Standards: Equipment leaks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... comply only with the provisions of this subpart: (i) 40 CFR part 60. (ii) 40 CFR part 61. (3) (4) The... successful repair of the leak. (iv) The maximum instrument reading measured by Method 21 of 40 CFR part 60...-type scaffold which would allow access to equipment up to 7.6 meters (25 feet) above the ground; or...

  6. 40 CFR 63.1255 - Standards: Equipment leaks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... following will be required to comply only with the provisions of this subpart: (i) 40 CFR part 60. (ii) 40 CFR part 61. (3) (4) The provisions in § 63.1(a)(3) of subpart A of this part do not alter the... successful repair of the leak. (iv) The maximum instrument reading measured by Method 21 of 40 CFR part...

  7. Locating and sealing air leaks in multiroomed buildings

    NASA Technical Reports Server (NTRS)

    Britton, J. M.

    1968-01-01

    Industrial, nontoxic smoke bombs are used in multiroomed buildings to locate and fill discovered leak areas with polyurethane foam. All obvious air escape routes are sealed and the room is then pressurized to a minimum of 0.1 inch water above the pressure of adjoining rooms.

  8. Leaks, Lumps, and Lines: Stigma and Women's Bodies

    ERIC Educational Resources Information Center

    Chrisler, Joan C.

    2011-01-01

    Women's bodies have often been positioned in art and popular culture as monstrous or defiled and women's bodily products (e.g., menstrual fluid, breast milk) as disgusting. This framing has led to the stigmatization of aspects of women's bodies (e.g., leaking fluids, lumps of fat, and lines in the skin that indicate aging), especially those…

  9. Prevention of Bile Leak after Liver Surgery: A Fool-proof Method

    PubMed Central

    Pujahari, Aswini K.

    2009-01-01

    Background/Aim: Bile leak is not uncommon after liver surgeries. There is no adequate method described to prevent this morbid complication. Materials and Methods: At the end of the liver procedure, transcystic normal saline was injected under pressure with distal clamping. Leaking saline on the cut surface of the liver was sutured. The process was repeated till no leaking was observed. A suction drain was kept for any bile leak. Results: Open liver resection and hydatid cyst surgery cases were included. There were 24 cases, with 13 males and 11 females. The age range was from 4 to 80 years, with a mean of 48 years (SD ± 17.7). The number of leak sites that could be sutured were 0-4 (mean of 2.3 ± 0.5). None had bile leak postoperatively. Conclusion: Transcystic injection under pressure with distal clamping demonstrates the leak sites. Suturing them prevents the postoperative bile leak. PMID:19568579

  10. CSNI specialist meeting on leak-before-break in nuclear reactor piping: proceedings

    SciTech Connect

    Not Available

    1984-08-01

    On September 1 and 2, 1983, the CSNI subcommittee on primary system integrity held a special meeting in Monterey, California, on the subject of leak-before-break in nuclear reactor piping systems. The purpose of the meeting was to provide an international forum for the exchange of ideas, positions, and research results; to identify areas requiring additional research and development; and to determine the general attitude toward acceptance of the leak-before-break concept. The importance of the leak-before-break issue was evidenced by excellent attendance at the meeting and through active participation by the meeting attendees. Approximately 125 people representing fifteen different nations attended the meeting. The meeting was divided into four technical sessions addressing the following areas: Application of Piping Fracture Mechanics to Leak-Before Break, Leak Rate and Leak Detection, Leak-Before-Break Studies, Methods and Results, Current and Proposed Positions on Leak-Before-Break.

  11. Management of Prolonged Pulmonary Air Leaks With Endobronchial Valve Placement

    PubMed Central

    Doelken, Peter; Pupovac, Stevan; Ata, Ashar; Fabian, Tom

    2016-01-01

    Background: Prolonged pulmonary air leaks (PALs) are associated with increased morbidity and extended hospital stay. We sought to investigate the role of bronchoscopic placement of 1-way valves in treating this condition. Methods: We queried a prospectively maintained database of patients with PAL lasting more than 7 days at a tertiary medical center. Main outcome measures included duration of chest tube placement and hospital stay before and after valve deployment. Results: Sixteen patients were eligible to be enrolled from September 2012 through December 2014. One patient refused to give consent, and in 4 patients, the source of air leak could not be identified with bronchoscopic balloon occlusion. Eleven patients (9 men; mean age, 65 ± 15 years) underwent bronchoscopic valve deployment. Eight patients had postoperative PAL and 3 had a secondary spontaneous pneumothorax. The mean duration of air leak before valve deployment was 16 ± 12 days, and the mean number of implanted valves was 1.9 (median, 2). Mean duration of hospital stay before and after valve deployment was 18 and 9 days, respectively (P = .03). Patients who had more than a 50% decrease in air leak on digital monitoring had the thoracostomy tube removed within 3–6 days. There were no procedural complications related to deployment or removal of the valves. Conclusions: Bronchoscopic placement of 1-way valves is a safe procedure that could help manage patients with prolonged PAL. A prospective randomized trial with cost-efficiency analysis is necessary to better define the role of this bronchoscopic intervention and demonstrate its effect on air leak duration.

  12. Management of Prolonged Pulmonary Air Leaks With Endobronchial Valve Placement

    PubMed Central

    Doelken, Peter; Pupovac, Stevan; Ata, Ashar; Fabian, Tom

    2016-01-01

    Background: Prolonged pulmonary air leaks (PALs) are associated with increased morbidity and extended hospital stay. We sought to investigate the role of bronchoscopic placement of 1-way valves in treating this condition. Methods: We queried a prospectively maintained database of patients with PAL lasting more than 7 days at a tertiary medical center. Main outcome measures included duration of chest tube placement and hospital stay before and after valve deployment. Results: Sixteen patients were eligible to be enrolled from September 2012 through December 2014. One patient refused to give consent, and in 4 patients, the source of air leak could not be identified with bronchoscopic balloon occlusion. Eleven patients (9 men; mean age, 65 ± 15 years) underwent bronchoscopic valve deployment. Eight patients had postoperative PAL and 3 had a secondary spontaneous pneumothorax. The mean duration of air leak before valve deployment was 16 ± 12 days, and the mean number of implanted valves was 1.9 (median, 2). Mean duration of hospital stay before and after valve deployment was 18 and 9 days, respectively (P = .03). Patients who had more than a 50% decrease in air leak on digital monitoring had the thoracostomy tube removed within 3–6 days. There were no procedural complications related to deployment or removal of the valves. Conclusions: Bronchoscopic placement of 1-way valves is a safe procedure that could help manage patients with prolonged PAL. A prospective randomized trial with cost-efficiency analysis is necessary to better define the role of this bronchoscopic intervention and demonstrate its effect on air leak duration. PMID:27647978

  13. Leaks in nuclear grade high efficiency aerosol filters

    SciTech Connect

    Scripsick, R.C.

    1994-07-01

    Nuclear grade high efficiency aerosol filters, also known as high efficiency particulate air (HEPA) filters, are commonly used in air cleaning systems for removal of hazardous aerosols. Performance of the filter units is important in assuring health and environmental protection. The filter units are constructed from pleated packs of fiberglass filter media sealed into rigid frames. Results of previous studies on such filter units indicate that their performance may not be completely predicted by ideal performance of the fibrous filter media. In this study, departure from ideal performance is linked to leaks existing in filter units and overall filter unit performance is derived from independent performance of the individual filter unit components. The performance of 14 nuclear grade HEPA filter units (size 1, 25 cfm) with plywood frames was evaluated with a test system that permitted independent determination of penetration as a function of particle size for the whole filter unit, the filter unit frame, and the filter media pack. Tests were performed using a polydisperse aerosol of di-2-ethylhexyl phthalate with a count median diameter of 0.2 {mu}m and geometric standard deviation of 1.6. Flow rate and differential pressure were controlled from 1% to 100% of design values. Particle counts were made upstream and downstream of the filter unit with an optical particle counter (OPC). The OPC provided count information in 28 size channels over the particle diameter range from 0.1 to 0.7 {mu}m. Results provide evidence for a two component leak model of filler unit performance with: (1) external leaks through filter unit frames, and (2) internal leaks through defects in the media and through the seal between the media pack and frame. For the filter units evaluated, these leaks dominate overall filter unit performance over much of the flow rate and particle size ranges tested.

  14. Assessment of historical leak model methodology as applied to the REDOX high-level waste tank SX-108

    SciTech Connect

    JONES, T.E.

    1999-09-22

    Using the Historical Leak Model approach, the estimated leak rate (and therefore, projected leak volume) for Tank 241-SX-108 could not be reproduced using the data included in the initial document describing the leak methodology. An analysis of parameters impacting tank heat load calculations strongly suggest that the historical tank operating data lack the precision and accuracy required to estimate tank leak volumes using the Historical Leak Model methodology.

  15. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    DOEpatents

    Weitz, Karl K.; Moore, Ronald J.

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  16. Hanford Single-Shell Tank Leak Causes and Locations - 241-B Farm

    SciTech Connect

    Girardot, Crystal L.; Harlow, Donald G.

    2013-07-11

    This document identifies 241-B Tank Farm (B Farm) leak cause and locations for the 100 series leaking tank (241-B-107) identified in RPP-RPT-49089, Hanford B-Farm Leak Inventory Assessments Report. This document satisfies the B Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  17. Program plan: acoustic leak detection/location development at GE-ARSD

    SciTech Connect

    1980-02-01

    Provide the development and subsequent specification, design and testing of an acoustic leak protection system which will detect a leak within a LMFBR steam generator. The goal for this system is to be at least as rapid and no more expensive than the chemical leak detection system under development for the Clinch River Breeder Reactor Plant (CRBRP).

  18. 40 CFR 60.562-2 - Standards: Equipment leaks of VOC.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Equipment leaks of VOC. 60...: Equipment leaks of VOC. (a) Each owner or operator of an affected facility subject to the provisions of this... from bleed ports in existing pumps in light liquid service are not considered to be a leak as...

  19. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipment leaks only. 65.146 Section 65.146 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only... nonflare control device used only to control emissions from equipment leaks. (c) Monitoring...

  20. 40 CFR 63.986 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment leaks only. 63.986 Section 63.986 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... leaks only. (a) Equipment and operating requirements. (1) Owners or operators using a nonflare control device to meet the applicable requirements of a referencing subpart for equipment leaks shall meet...

  1. 40 CFR 63.986 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipment leaks only. 63.986 Section 63.986 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... leaks only. (a) Equipment and operating requirements. (1) Owners or operators using a nonflare control device to meet the applicable requirements of a referencing subpart for equipment leaks shall meet...

  2. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment leaks only. 65.146 Section 65.146 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only... nonflare control device used only to control emissions from equipment leaks. (c) Monitoring...

  3. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment leaks only. 65.146 Section 65.146 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only... nonflare control device used only to control emissions from equipment leaks. (c) Monitoring...

  4. 40 CFR 63.986 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment leaks only. 63.986 Section 63.986 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... leaks only. (a) Equipment and operating requirements. (1) Owners or operators using a nonflare control device to meet the applicable requirements of a referencing subpart for equipment leaks shall meet...

  5. 46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are...

  6. 40 CFR 63.986 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment leaks only. 63.986 Section 63.986 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... leaks only. (a) Equipment and operating requirements. (1) Owners or operators using a nonflare control device to meet the applicable requirements of a referencing subpart for equipment leaks shall meet...

  7. 46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are...

  8. 46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are...

  9. 46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are...

  10. 46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are...

  11. 40 CFR 63.986 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment leaks only. 63.986 Section 63.986 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... leaks only. (a) Equipment and operating requirements. (1) Owners or operators using a nonflare control device to meet the applicable requirements of a referencing subpart for equipment leaks shall meet...

  12. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment leaks only. 65.146 Section 65.146 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only... nonflare control device used only to control emissions from equipment leaks. (c) Monitoring...

  13. 40 CFR 60.562-2 - Standards: Equipment leaks of VOC.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Equipment leaks of VOC. 60...: Equipment leaks of VOC. (a) Each owner or operator of an affected facility subject to the provisions of this... from bleed ports in existing pumps in light liquid service are not considered to be a leak as...

  14. 40 CFR 60.562-2 - Standards: Equipment leaks of VOC.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Equipment leaks of VOC. 60...: Equipment leaks of VOC. (a) Each owner or operator of an affected facility subject to the provisions of this... from bleed ports in existing pumps in light liquid service are not considered to be a leak as...

  15. 40 CFR 60.562-2 - Standards: Equipment leaks of VOC.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Equipment leaks of VOC. 60...: Equipment leaks of VOC. (a) Each owner or operator of an affected facility subject to the provisions of this... from bleed ports in existing pumps in light liquid service are not considered to be a leak as...

  16. 40 CFR 60.562-2 - Standards: Equipment leaks of VOC.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Equipment leaks of VOC. 60...: Equipment leaks of VOC. (a) Each owner or operator of an affected facility subject to the provisions of this... from bleed ports in existing pumps in light liquid service are not considered to be a leak as...

  17. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment leaks only. 65.146 Section 65.146 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only... nonflare control device used only to control emissions from equipment leaks. (c) Monitoring...

  18. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... couplings and operates at less than 40 percent of SMYS. (2) If the leak is due to a corrosion pit, install a properly designed bolt-on-leak clamp. (3) If the leak is due to a corrosion pit and on pipe of not...

  19. Leaking and Death-Threats by Students: A Study in German Schools

    ERIC Educational Resources Information Center

    Bondü, Rebecca; Scheithauer, Herbert

    2014-01-01

    Leaking comprises observable behavior or statements that signal intentions of committing a violent offense and is considered an important warning sign for school shootings. School staff who are confronted with leaking have to assess its seriousness and react appropriately--a difficult task, because knowledge about leaking is sparse. The present…

  20. Hanford Double-Shell Tank AY-102 Radioactive Waste Leak Investigation Update

    SciTech Connect

    Washenfelder, Dennis J.

    2015-02-03

    The presentation outline is: Briefly review leak integrity status of tank AY-102 and current leak behavior; Summarize recent initiatives to understand leak mechanism and to verify integrity of remaining waste confinement structures; describe planned waste recovery activities; and, introduce other papers on tank AY-102 topics.

  1. Assessment of Remote Sensing Technologies for Location of Hydrogen and Helium Leaks

    NASA Technical Reports Server (NTRS)

    Sellar, R. Glenn; Wang, Danli

    2000-01-01

    The objective of this initial phase of this research effort is to: 1) Evaluate remote sensing technologies for location of leaks of gaseous molecular hydrogen (H2) and gaseous helium (He) in air, for space transportation applications; and 2) Develop a diffusion model that predicts concentration of H2 or He gas as a function of leak rate and distance from the leak.

  2. PORTABLE IMAGING DEVICES FOR INDUSTRIAL LEAK DETECTION AT PETROLEUM REFINERIES AND CHEMICAL PLANTS

    EPA Science Inventory

    Undiscovered gas leaks, or fugitive emissions, in chemical plants and refinery operations can impact regional air quality as well as being a public health problem. Surveying a facility for potential gas leaks can be a daunting task. Industrial Leak Detection and Repair (LDAR) pro...

  3. A coupled model for solid deformation and gas leak flow

    NASA Astrophysics Data System (ADS)

    Sun, Peide; Wan, Huagen

    2004-09-01

    From the viewpoint of interaction mechanics of solid and gas, a coupled mathematical model is presented for solid coal/rock-mass deformation and gas leak flow in parallel deformable coal seams. Numerical solutions using the strong implicit procedure (SIP) method to the coupled mathematical model for double parallel coal seams are also developed in detail. Numerical simulations for the prediction of safety range using protection layer mining are performed with experimental data from a mine with potential danger of coal/gas outbursts. Analyses show that the numerical simulation results are consistent with the measured data on the spot. The coupled model shows a positive future for applications in a wide range of gas-leak-flow-related problems in mining engineering, gas drainage engineering and mining safety engineering. Copyright

  4. Area Monitoring for Detection of Leaks and/or Flames

    NASA Technical Reports Server (NTRS)

    Mian, Zahid F. (Inventor); Gamache, Ronald W. (Inventor); Glasser, Nick (Inventor)

    2015-01-01

    A solution for monitoring an area for the presence of a flame and/or a leak, such as from a pressurized fluid, is provided. An imaging device can be used that acquires image data based on electromagnetic radiation having wavelengths only corresponding to at least one region of the electromagnetic spectrum in which electromagnetic radiation from an ambient light source is less than the electromagnetic radiation emitted by at least one type of flame for which the presence within the area is being monitored. An acoustic device can be used that is configured to acquire acoustic data for the area and enhance acoustic signals in a range of frequencies corresponding to a leak of a pressurized fluid present in the area.

  5. Massive Cerebrospinal Fluid Leak of the Temporal Bone

    PubMed Central

    Manno, Alessandra; Pasqualitto, Emanuela; Ciofalo, Andrea; Angeletti, Diletta; Pasquariello, Benedetta

    2016-01-01

    Cerebrospinal fluid (CSF) leakage of the temporal bone region is defined as abnormal communications between the subarachnoidal space and the air-containing spaces of the temporal bone. CSF leak remains one of the most frequent complications after VS surgery. Radiotherapy is considered a predisposing factor for development of temporal bone CSF leak because it may impair dural repair mechanisms, thus causing inadequate dural sealing. The authors describe the case of a 47-year-old man with a massive effusion of CSF which extended from the posterior and lateral skull base to the first cervical vertebrae; this complication appeared after a partial enucleation of a vestibular schwannoma (VS) with subsequent radiation treatment and second operation with total VS resection. PMID:27597915

  6. MCO combustible gas management leak test acceptance criteria

    SciTech Connect

    SHERRELL, D.L.

    1999-05-11

    Existing leak test acceptance criteria for mechanically sealed and weld sealed multi-canister overpacks (MCO) were evaluated to ensure that MCOs can be handled and stored in stagnant air without compromising the Spent Nuclear Fuel Project's overall strategy to prevent accumulation of combustible gas mixtures within MCO's or within their surroundings. The document concludes that the integrated leak test acceptance criteria for mechanically sealed and weld sealed MCOs (1 x 10{sup -5} std cc/sec and 1 x 10{sup -7} std cc/sec, respectively) are adequate to meet all current and foreseeable needs of the project, including capability to demonstrate compliance with the NFPA 60 Paragraph 3-3 requirement to maintain hydrogen concentrations [within the air atmosphere CSB tubes] t or below 1 vol% (i.e., at or below 25% of the LFL).

  7. Method for HEPA filter leak scanning with differentiating aerosol detector

    SciTech Connect

    Kovach, B.J.; Banks, E.M.; Wikoff, W.O.

    1997-08-01

    While scanning HEPA filters for leaks with {open_quotes}Off the Shelf{close_quote} aerosol detection equipment, the operator`s scanning speed is limited by the time constant and threshold sensitivity of the detector. This is based on detection of the aerosol density, where the maximum signal is achieved when the scanning probe resides over the pinhole longer than several detector time-constants. Since the differential value of the changing signal can be determined by observing only the first small fraction of the rising signal, using a differentiating amplifier will speed up the locating process. The other advantage of differentiation is that slow signal drift or zero offset will not interfere with the process of locating the leak, since they are not detected. A scanning hand-probe attachable to any NUCON{reg_sign} Aerosol Detector displaying the combination of both aerosol density and differentiated signal was designed. 3 refs., 1 fig.

  8. Management of Leaks in Hydrogen Production, Delivery, and Storage Systems

    SciTech Connect

    Rawls, G

    2006-04-27

    A systematic approach to manage hydrogen leakage from components is presented. Methods to evaluate the quantity of hydrogen leakage and permeation from a system are provided by calculation and testing sensitivities. The following technology components of a leak management program are described: (1) Methods to evaluate hydrogen gas loss through leaks; (2) Methods to calculate opening areas of crack like defects; (3) Permeation of hydrogen through metallic piping; (4) Code requirements for acceptable flammability limits; (5) Methods to detect flammable gas; (6) Requirements for adequate ventilation in the vicinity of the hydrogen system; (7) Methods to calculate dilution air requirements for flammable gas mixtures; and (8) Concepts for reduced leakage component selection and permeation barriers.

  9. Ultrasonic flowmeters offer oil line leak-detection potential

    SciTech Connect

    Hettrich, U.

    1995-04-01

    Ultrasonic flowmeters (USFM) installed on Transalpine Pipeline Co.`s (TAL) crude-oil system have proven to be a cost-effective flow measurement technique and beneficial in batch identification and leak detection. Through close examination, TAL has determined that clamp-on USFMs offer cost-saving advantages in installation, maintenance and operation. USFMs do not disturb pig passage. The technique also provides sound velocity capabilities, which can be used for liquid identification and batch tracking. The instruments have a repeatability of better than 0.25% and achieve an accuracy of better than 1%, depending on the flow profiles predictability. Using USFMs with multiple beams probably will improve accuracy further and it should be possible to find leaks even smaller than 1% of flow.

  10. Massive Cerebrospinal Fluid Leak of the Temporal Bone.

    PubMed

    Iannella, Giannicola; Manno, Alessandra; Pasqualitto, Emanuela; Ciofalo, Andrea; Angeletti, Diletta; Pasquariello, Benedetta; Magliulo, Giuseppe

    2016-01-01

    Cerebrospinal fluid (CSF) leakage of the temporal bone region is defined as abnormal communications between the subarachnoidal space and the air-containing spaces of the temporal bone. CSF leak remains one of the most frequent complications after VS surgery. Radiotherapy is considered a predisposing factor for development of temporal bone CSF leak because it may impair dural repair mechanisms, thus causing inadequate dural sealing. The authors describe the case of a 47-year-old man with a massive effusion of CSF which extended from the posterior and lateral skull base to the first cervical vertebrae; this complication appeared after a partial enucleation of a vestibular schwannoma (VS) with subsequent radiation treatment and second operation with total VS resection. PMID:27597915

  11. Troponin leak associated with drug-induced methemoglobinemia.

    PubMed

    Cannon, Robert D; Wagner, Michael; Jacoby, Jeanne L

    2014-10-01

    Drug-induced methemoglobinemia is a well-described entity but has not been previously associated with elevated troponins in the absence of cardiac symptoms. We report a case of a patient presenting to the emergency department (ED) with complaints related to an exacerbation of her long-standing cystitis. A low pulse oximetry reading prompted an evaluation, revealing a troponin leak, which peaked at 10 hours. Her methemoglobin level was found to be elevated at 11.4%, but a preexisting anemia apparently prevented the clinical recognition of cyanosis. The methemoglobinemia was determined to be secondary to her ingestion of phenazopyridine and trimethoprim-sulfa methoxizole. Although phenazopyridine and sulfa agents have long been known to cause methemoglobinemia, our patient exhibited an asymptomatic troponin leak that has not been previously reported as a complication of drug-induced methemoglobinemia. Clinicians should be aware of this potential association.

  12. Oil/gas collector/separator for underwater oil leaks

    SciTech Connect

    Henning, C.D.

    1993-05-25

    An oil/gas collector/separator for underwater oil leaks is described comprising: a cylindrical tank; a hollow float member for supporting said tank in a substantially upright position; a skirt assembly secured to said hollow float member and extending in a direction away from said float member opposite said tank; means for removing oil from said tank; and means for removing gas from said tank.

  13. Microsecond yellow laser for subfoveal leaks in central serous chorioretinopathy

    PubMed Central

    Ambiya, Vikas; Goud, Abhilash; Mathai, Annie; Rani, Padmaja Kumari; Chhablani, Jay

    2016-01-01

    Purpose To evaluate the role of navigated yellow microsecond laser in treating subfoveal leaks in nonresolving central serous chorioretinopathy (CSC). Methods This prospective study included ten eyes of ten consecutive patients with nonresolving CSC with subfoveal leaks. All eyes were treated with 577 nm navigated yellow microsecond laser (5% duty cycle). Key inclusion criteria include a vision loss for a duration of minimum 3 months duration due to focal subfoveal leak on fluorescein angiography. Key exclusion criteria include prior treatment for CSC and any signs of chronic CSC. Comprehensive examination, in addition to low-contrast visual acuity assessment, microperimetry, autofluorescence, spectral domain optical coherence tomography, and fundus fluorescein angiography, was done at baseline, 1, 3, and 6 months after treatment. Rescue laser was performed as per predefined criteria at 3 months. Results The average best-corrected visual acuity improved from 73.3±16.1 letters to 75.8±14.0 (P=0.69) at 3 months and 76.9±13.0 (P=0.59) at 6 months, but was not statistically significant. Low-contrast visual acuity assessment (logMAR) improved from 0.41±0.32 to 0.35±0.42 (P=0.50) at 3 months and 0.28±0.33 (P=0.18) at 6 months. Average retinal sensitivity significantly improved from baseline 18.93±7.19 dB to 22.49±6.67 dB (P=0.01) at 3 months and 21.46±8.47 dB (P=0.04) at 6 months. Rescue laser was required only in one eye at 3 months; however, laser was required in three eyes at 6 months. Conclusion Microsecond laser is a safe and effective modality for treating cases of nonresolving CSC with subfoveal leaks. PMID:27570446

  14. 105-KE Isolation Barrier Leak Rate Acceptance Test Report

    SciTech Connect

    McCracken, K.J.

    1995-06-14

    This Acceptance Test Report (ATR) contains the completed and signed Acceptance Procedure (ATP) for the 105-KE Isolations Barrier Leak Rate Test. The Test Engineer`s log, the completed sections of the ATP in the Appendix for Repeat Testing (Appendix K), the approved WHC J-7s (Appendix H), the data logger files (Appendices T and U), and the post test calibration checks (Appendix V) are included.

  15. ACOUSTIC LOCATION OF LEAKS IN PRESSURIZED UNDER- GROUND PETROLEUM PIPELINES

    EPA Science Inventory

    Experiments were conducted at the Underground Storage Tank (UST) Test Apparatus Pipeline in which three acoustic sensors separated by a maximum distance of 38.1 m (125 ft) were used to monitor signals produced by 11.4-, 5.7-, and 3.8-L/h (3.0-, 1.5-, and 1.0-gal/h) leaks in th...

  16. Treatment of anastomotic leaks with metallic stent after esophagectomies.

    PubMed

    Eizaguirre, E; Larburu, S; Asensio, J I; Rodriguez, A; Elorza, J L; Loyola, F; Urdapilleta, G; Navascués, J M E

    2016-01-01

    The diagnosis and the treatment of anastomotic leak after esophagectomy are the keys to reduce the morbidity and mortality after this surgery. The stent plays an important role in the treatment of the leakage and in the prevention of reoperation. We have analyzed the database of the section of the esophagogastric surgery of Donostia University Hospital from June 2003 to May 2012. It is a retrospective study of 113 patients with esophagectomy resulting from tumor, and 24 (21.13%) of these patients developed anastomotic leak. Of these 24 patients, 13 (54.16%) have been treated with a metallic stent and 11 (45.84%) without a stent. The average age of the patients was 55.69 and 62.45 years, respectively. All patients treated with and without a stent have been males. Eight (61.5%) stents were placed in the neck and five (38.5%) in the chest. However, among the 11 fistulas treated without a stent, 9 patients had cervical anastomosis (81.81%) and 2 patients (18.18%) had anastomosis in the chest. Twelve patients (92.30%) with a stent preserve digestive continuity, and 10 patients (90.90%) were treated without a stent. One patient died in the stent group and one in the nonstent group. The treatment with metallic stent of the anastomotic leak after esophagectomy is an option that can prevent reoperation in these patients, but it does not decrease the average of the hospital stay. The stent may be more useful in thoracic anastomotic leaks.

  17. Leak detection, monitoring, and mitigation technology trade study update

    SciTech Connect

    HERTZEL, J.S.

    1998-11-10

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful.

  18. The minimal leak test technique for endotracheal cuff maintenance.

    PubMed

    DA, Harvie; Jn, Darvall; M, Dodd; A, De La Cruz; M, Tacey; Rl, D'Costa; D, Ward

    2016-09-01

    Endotracheal tube (ETT) cuff pressure management is an essential part of airway management in intubated and mechanically ventilated patients. Both under- and over-inflation of the ETT cuff can lead to patient complications, with an ideal pressure range of 20-30 cmH2O defined. A range of techniques are employed to ensure adequate ETT cuff inflation, with little comparative data. We performed an observational cross-sectional study in a tertiary metropolitan ICU, assessing the relationship between the minimal leak test and cuff manometry. Forty-five mechanically ventilated patients, over a three-month period, had ETT cuff manometry performed at the same time as their routine cuff maintenance (minimal leak test). Bedside nurse measurements were compared with investigator measurements. At the endpoint of cuff inflation, 20 of 45 patients (44%) had cuff pressures between 20 and 30 cmH2O; 11 of 45 patients (24%) had cuff pressures <20 cmH2O; 14 of 45 patients (31%) had cuff pressures ≥30 cmH2O. Univariate analysis demonstrated an association between both patient obesity and female gender requiring less ETT cuff volume (P=0.008 and P <0.001 respectively), though this association was lost on multivariate analysis. No association was demonstrated between any measured variables and cuff pressures. Inter-operator reliability in performing the minimal leak test showed no evidence of bias between nurse and investigators (Pearson coefficient = 0.897). We conclude the minimal leak test for maintenance of ETT cuffs leads to both over- and under-inflation, and alternative techniques, such as cuff manometry, should be employed. PMID:27608343

  19. Anastomotic leaks after colorectal anastomosis occurring more than 30 days postoperatively: a single-institution evaluation.

    PubMed

    Tan, Wei Phin; Hong, En Yaw; Phillips, Benjamin; Isenberg, Gerald A; Goldstein, Scott D

    2014-09-01

    National hospital registries only report colorectal anastomotic leaks (ALs) within 30 days postoperatively. The aim of our study was to determine the incidence and significance of ALs that occur beyond 30 days postoperatively. We performed a retrospective review of our prospective database from June 2008 to August 2012. A total of 504 patients were included. These patients were operated on by two surgeons. Any clinical or radiographic abnormalities were considered to be an anastomotic imperfection. A total of 504 patients were reviewed with a total of 18 (3.6%) anastomotic leaks. Six leaks (31.6% of leaks) were diagnosed more than 30 days postoperatively (P < 0.001). Of the 18 leaks, interventional radiology drainage was performed for four cases and 14 patients required reoperation. All six delayed leaks required reoperation. There was one leak that occurred under 30 days, which was discovered on autopsy. The median follow-up was 12 months (range, 1 to 4 months). All the delayed leak patients presented with fistulas, whereas 58 per cent of typical leak patients presented with the triad of leukocytosis, fever, and abdominal pain. Colorectal anastomotic leaks can occur after the 30-day postoperative period. In patients with vague and atypical abdominal findings, anastomotic leak must be suspected. More systematic, prospective studies are required to help us further understand the risk factors and natural history of anastomotic failures in elective colorectal surgery.

  20. Leak detection using the pattern of sound signals in water supply systems

    NASA Astrophysics Data System (ADS)

    Sato, Toshitaka; Mita, Akira

    2007-04-01

    Water supply systems in Japan contribute significantly to improve public health. Unfortunately, there are many age-deteriorated pipes of various sizes and leaks frequently occur. Particularly devastating are hidden leaks occurring underground because when left undetected for years these leaks result in secondary damage. Thus, early detection and treatment of leaks is an important civil engineering challenge. At present the acoustic method is the most popular leak detection method. The purpose of this study is to propose an easy and stable leak detection method using the acoustic method assisted by pattern recognition techniques. In the proposed method we collect in the form of digital signals sound and pseudo-sound samples of underground leaking pipes. Principal component analysis (PCA) of the power spectrum of one leak sound is made, and a new coordinate system is constructed. We project the other sounds in the coordinate system, and evaluate if the sounds are similar to the sample sound or not by comparing the residual between the original and the projection. Next, we evaluate the DSF (Damage Sensitive Feature), which is a function of the first three AR model. At last, the feature vectors are created by combining the residuals, the DSF, and the damping ratio of the AR model, and a leak detection method is proposed using the Support Vector Machine (SVM) based upon them. In this study, it is shown that the residual and DSF are useful indices for leak detection. Furthermore, the proposed method shows high accuracy in recognizing leaks.

  1. Leak injection/detection input for B and W prototype steam generator test request

    SciTech Connect

    1980-11-18

    The goal of the leak injection/detection phase of the test program on the prototype steam generator is to obtain data that can be used to specify the leak protection system for the plant unit steam generators. Both chemical and two acoustic leak detection methods (by GE and Rockwell International) are to be considered. The chemical system has been selected as the reference based on its more developed state. The acoustic methods have potential both as small leak detection systems and as intermediate leak protection/automatic shutdown systems. Simulated leak injections will be made at various locations within the steam generator to determine the performance of the chemical system as specifically applied to the B and W helical coil steam generator geometry. Acoustic tests will be made to characterize the various steam generator background noise sources and to record acoustic signals during smulated leak injections, in order to predict the performance of both systems.

  2. Transnasal endoscopic treatment of cerebrospinal fluid leak: 17 years’ experience

    PubMed Central

    Presutti, L; Mattioli, F; Villari, D; Marchioni, D; Alicandri-Ciufelli, M

    2009-01-01

    Summary Aim of this report is to describe the long-term results of endoscopic endonasal repair of cerebrospinal fluid leak using a septal mucoperichondrial graft. A case series of 52 patients operated for cerebrospinal fluid rhinorrhea between 1990 and 2006 is presented. All patients underwent surgical treatment for endoscopic endonasal closure of a cerebrospinal fluid leak using a septal mucoperichondrial graft. No lumbar drain and fluorescein tests were used. The intra-operative localization of the fistula was aided by Valsalva’s manoeuvre by the anaesthetist. The success rate, after the first attempt, was 88.5% (46/52 patients); for the remaining 11.5% (6/52 patients), a second attempt was necessary which proved successful in 5 cases, raising the overall success rate to 98.1% (51/52 patients). Relapse occurred in only one case (1.9%), after the second attempt. In conclusion, a free mucoperichondrial graft offered good results for cerebrospinal fluid leak repair. In the Authors’ experience, a high success rate can be achieved without the use of intrathecal fluorescein and lumbar drain. PMID:20161876

  3. A voice-actuated wind tunnel model leak checking system

    NASA Technical Reports Server (NTRS)

    Larson, William E.

    1989-01-01

    A computer program has been developed that improves the efficiency of wind tunnel model leak checking. The program uses a voice recognition unit to relay a technician's commands to the computer. The computer, after receiving a command, can respond to the technician via a voice response unit. Information about the model pressure orifice being checked is displayed on a gas-plasma terminal. On command, the program records up to 30 seconds of pressure data. After the recording is complete, the raw data and a straight line fit of the data are plotted on the terminal. This allows the technician to make a decision on the integrity of the orifice being checked. All results of the leak check program are stored in a database file that can be listed on the line printer for record keeping purposes or displayed on the terminal to help the technician find unchecked orifices. This program allows one technician to check a model for leaks instead of the two or three previously required.

  4. [Prevention and control of postoperative anastomotic leak after colorectal anastomosis].

    PubMed

    Zheng, Peng; Xu, Jianmin

    2016-04-01

    Anastomotic leak is a major complication after colorectal resection. Risk factors for anastomotic leak include patient and disease related factors, preoperative factors(e.g. use of neoadjuvant chemoradiation and mechanical bowel preparation), intraoperative factors(e.g. anastomotic techniques, performing of water injection test, preventive colostomy, and surgical procedures, etc; postoperative factors, such as postoperative medication use, etc. Early diagnosis of anastomotic fistula is crucial, which can be made by combining laboratory examination with imaging examination or take the prediction and diagnosis model as reference. Once diagnosed, anastomotic leak should be managed immediately according to individual status and severity of disease. As for intraperitoneal anastomosis, no matter whether the bowel lack of blood supply or not, original anastomosis should be removed and terminal loop ileumstomy should be created. As for extraperitoneal anastomosis(mainly low rectal anastomosis), adequate drainage and terminal loop ileumstomy can be considered when anastomosis is slightly cracked or invisible due to adhesion. When anastomosis is severely cracked or blood supply is too limited, however, we must disconnect the original anastomotic and create a proximal colostomy.

  5. Optimization of the leak conductance in the squid giant axon.

    PubMed

    Seely, Jeffrey; Crotty, Patrick

    2010-08-01

    We report on a theoretical study showing that the leak conductance density, G{L} , in the squid giant axon appears to be optimal for the action potential firing frequency. More precisely, the standard assumption that the leak current is composed of chloride ions leads to the result that the experimental value for G{L} is very close to the optimal value in the Hodgkin-Huxley model, which minimizes the absolute refractory period of the action potential, thereby maximizing the maximum firing frequency under stimulation by sharp, brief input current spikes to one end of the axon. The measured value of G{L} also appears to be close to optimal for the frequency of repetitive firing caused by a constant current input to one end of the axon, especially when temperature variations are taken into account. If, by contrast, the leak current is assumed to be composed of separate voltage-independent sodium and potassium currents, then these optimizations are not observed.

  6. Electrical detection of liquid lithium leaks from pipe jointsa)

    NASA Astrophysics Data System (ADS)

    Schwartz, J. A.; Jaworski, M. A.; Mehl, J.; Kaita, R.; Mozulay, R.

    2014-11-01

    A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

  7. Endoscopic management of gastrointestinal perforations, leaks and fistulas

    PubMed Central

    Rogalski, Pawel; Daniluk, Jaroslaw; Baniukiewicz, Andrzej; Wroblewski, Eugeniusz; Dabrowski, Andrzej

    2015-01-01

    Gastrointestinal perforations, leaks and fistulas may be serious and life-threatening. The increasing number of endoscopic procedures with a high risk of perforation and the increasing incidence of leakage associated with bariatric operations call for a minimally invasive treatment for these complications. The therapeutic approach can vary greatly depending on the size, location, and timing of gastrointestinal wall defect recognition. Some asymptomatic patients can be treated conservatively, while patients with septic symptoms or cardio-pulmonary insufficiency may require intensive care and urgent surgical treatment. However, most gastrointestinal wall defects can be satisfactorily treated by endoscopy. Although the initial endoscopic closure rates of chronic fistulas is very high, the long-term results of these treatments remain a clinical problem. The efficacy of endoscopic therapy depends on several factors and the best mode of treatment will depend on a precise localization of the site, the extent of the leak and the endoscopic appearance of the lesion. Many endoscopic tools for effective closure of gastrointestinal wall defects are currently available. In this review, we summarized the basic principles of the management of acute iatrogenic perforations, as well as of postoperative leaks and chronic fistulas of the gastrointestinal tract. We also described the effectiveness of various endoscopic methods based on current research and our experience. PMID:26457014

  8. An improved PCA method with application to boiler leak detection.

    PubMed

    Sun, Xi; Marquez, Horacio J; Chen, Tongwen; Riaz, Muhammad

    2005-07-01

    Principal component analysis (PCA) is a popular fault detection technique. It has been widely used in process industries, especially in the chemical industry. In industrial applications, achieving a sensitive system capable of detecting incipient faults, which maintains the false alarm rate to a minimum, is a crucial issue. Although a lot of research has been focused on these issues for PCA-based fault detection and diagnosis methods, sensitivity of the fault detection scheme versus false alarm rate continues to be an important issue. In this paper, an improved PCA method is proposed to address this problem. In this method, a new data preprocessing scheme and a new fault detection scheme designed for Hotelling's T2 as well as the squared prediction error are developed. A dynamic PCA model is also developed for boiler leak detection. This new method is applied to boiler water/steam leak detection with real data from Syncrude Canada's utility plant in Fort McMurray, Canada. Our results demonstrate that the proposed method can effectively reduce false alarm rate, provide effective and correct leak alarms, and give early warning to operators.

  9. MWTF jumper connector integral seal block development and leak testing

    SciTech Connect

    Ruff, E.S.; Jordan, S.R.

    1995-01-01

    In fiscal year 1993, tests of an o-ring/tetraseal retainer designed to replace a gasket-type seal used in PUREX-type process jumper connectors encouraged the design of an improved seal block. This new seal block combines several parts into one unitized component called an integral seal block. This report summarizes development and leak testing of the new integral seal block. The integral seal block uses a standard o-ring nested in a groove to accomplish leak tightness. This seal block eliminates the need to machine acme threads into the lower skirt casting and seal retainers, eliminates tolerance stack-up, reduces parts inventory, and eliminates an unnecessary leak path in the jumper connector assembly. This report also includes test data on various types of o-ring materials subjected to heat and pressure. Materials tested included Viton, Kalrez, and fluorosilicone, with some incidental data on teflon coated silicone o-rings. Test experience clearly demonstrates the need to test each seal material for temperature and pressure in its intended application. Some materials advertised as being {open_quotes}better{close_quotes} at higher temperatures did not perform up to expectations. Inspection of the fluorosilicone and Kalrez seals after thermal testing indicates that they are much more susceptible to heat softening than Viton.

  10. Liquid metal-to-gas leak-detection instruments. [LMFBR

    SciTech Connect

    Matlin, E.; Witherspoon, J.E.; Johnson, J.L.

    1982-01-01

    It is desirable for liquid-metal-cooled reactors that small liquid metal-to-gas leaks be reliably detected. Testing has been performed on a number of detection systems to evaluate their sensitivity, response time, and performance characteristics. This testing has been scheduled in three phases. The first phase was aimed at screening out the least suitable detectors and optimizing the performance of the most promising. In the second phase, candidates were tested in a 1500 ft/sup 3/ walk-in type enclosure in which leaks were simulated on 24-in. and 3-in. piping. In the third phase of testing, selected type detectors were tested in the 1500-ft/sup 3/ enclosure with Clinch River Breeder Reactor Plant (CRBRP) pipe insulation configurations and detector tubing configuration with cell gas recirculation simulated. Endurance testing of detection equipment was also performed as part of this effort. Test results have been shown that aerosol-type detectors will reliably detect leaks as small as a few grams per hour when sampling pipe insulation annuli.

  11. Electrical detection of liquid lithium leaks from pipe joints

    SciTech Connect

    Schwartz, J. A. Jaworski, M. A.; Mehl, J.; Kaita, R.; Mozulay, R.

    2014-11-15

    A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

  12. Engineering study of tank leaks related to hydraulic retrieval of sludge from tank 241-C-106. Revision 1

    SciTech Connect

    Lowe, S.S.; Carlos, W.C.; Irwin, J.J.; Khaleel, R.; Kline, N.W.; Ludowise, J.D.; Marusich, R.M.; Rittman, P.D.

    1993-06-09

    This study evaluates hydraulic retrieval (sluicing) of the waste in single-shell tank 241-C-106 with respect to the likelihood of tank leaks, gross volumes of potential leaks, and their consequences. A description of hydraulic retrieval is developed to establish a baseline for the study. Leak models are developed based on postulated leak mechanisms to estimate the amount of waste that could potentially leak while sluicing. Transport models describe the movement of the waste constituents in the surrounding soil and groundwater after a leak occurs. Environmental impact and risk associated with tank leaks are evaluated. Transport of leaked material to the groundwater is found to be dependent on the rate of recharge of moisture in the soil for moderate-sized leaks. Providing a cover over the tank and surrounding area would eliminate the recharge. The bulk of any leaked material would remain in the vicinity of the tank for remedial action.

  13. Transjugular approach for transcatheter closure of mitral paraprosthetic leak.

    PubMed

    Joseph, George; Thomson, Viji Samuel

    2009-11-15

    Transcatheter closure of mitral paraprosthetic leak (PPL) using femoral antegrade transseptal or retrograde approach is often unsuccessful when the involved part of the mitral annulus is difficult to access or when the left atrium is large. We report the successful use of jugular venous approach to perform transseptal antegrade PPL closure in a 49-year-old male with mitral PPL located in the anteromedial part of the annulus. This technique could serve as a useful alternative in patients in whom transcatheter closure of mitral PPL is technically difficult. PMID:19626688

  14. Tritium leak triggers reactor shutdown in the US

    NASA Astrophysics Data System (ADS)

    Gwynne, Peter

    2010-04-01

    A US state has voted against renewing the operating licence for its only working nuclear reactor after a leak of tritium was found in the 38-year-old power plant. The decision in late February by Vermont's senate to close the 650 MW Vermont Yankee reactor has cast a shadow over the Obama administration's plans to encourage the construction of more nuclear power plants to meet the country's increasing electricity demands. The plant currently provides one-third of the state's electricity demands.

  15. 82. Photocopied August 1978. PREPARATIONS FOR REPAIRING A FOREBAY LEAK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    82. Photocopied August 1978. PREPARATIONS FOR REPAIRING A FOREBAY LEAK IN 1907, VIEW FROM FOREBAY. THE SILLS OF THE FOREBAY APRON WHICH HAD CRACKED AND SAGGED ARE CLEARLY VISIBLE IN THE CENTER OF THE PHOTOGRAPH. NOTE ALSO THE PENSTOCK GATE SECTION AND THE TRAVELLING GATE HOIST ABOVE THE DAMAGED AREA. THIS WAS THE MEANS USED FOR SHUTTING OFF INDIVIDUAL PENSTOCKS PRIOR TO C. 1920. THREE OF THE SECTIONS (WOODEN) SHOWN WERE REQUIRED TO CLOSE OFF A PENSTOCK. THE TRAVELLING HOIST WAS MANUALLY OPERATED. (511) - Michigan Lake Superior Power Company, Portage Street, Sault Ste. Marie, Chippewa County, MI

  16. What was leaking from a hazardous-waste dump

    SciTech Connect

    Hites, R.A.

    1988-05-15

    The city of Niagara Falls, N.Y., is the home of several toxic waste disposal sites, the most famous of which is Love Canal. Although less well known, the Hyde Park dump is equally noxious. This hazardous-waste dump was operated by the Hooker Chemical Company from about 1953 to 1975. Approximately 55,000 tons of halogenated waste were buried at this site, which is just north of the city. The Hyde Park dump is drained by Bloody Run Creek. Ronald A. Hites of Indiana University outlines the steps taken to identify the structures of organic compounds leaking from the Hyde Park dump.

  17. Fiber-Optic Based Compact Gas Leak Detection System

    NASA Technical Reports Server (NTRS)

    deGroot, Wim A.

    1995-01-01

    A propellant leak detection system based on Raman scattering principles is introduced. The proposed system is flexible and versatile as the result of the use of optical fibers. It is shown that multiple species can be monitored simultaneously. In this paper oxygen, nitrogen, carbon monoxide, and hydrogen are detected and monitored. The current detection sensitivity for both hydrogen and carbon monoxide is 1% partial pressure at ambient conditions. The sensitivity for oxygen and nitrogen is 0.5% partial pressure. The response time to changes in species concentration is three minutes. This system can be used to monitor multiple species at several locations.

  18. Carbon granule probe microphone for leak detection. [recovery boilers

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P. (Inventor)

    1985-01-01

    A microphone which is not subject to corrosion is provided by employing carbon granules to sense sound waves. The granules are packed into a ceramic tube and no diaphragm is used. A pair of electrodes is located in the tube adjacent the carbon granules and are coupled to a sensing circuit. Sound waves cause pressure changes on the carbon granules which results in a change in resistance in the electrical path between the electrodes. This change in resistance is detected by the sensing circuit. The microphone is suitable for use as a leak detection probe in recovery boilers, where it provides reliable operation without corrosion problems associated with conventional microphones.

  19. Energetic neutrons leaking from the top of the atmosphere.

    NASA Technical Reports Server (NTRS)

    Merker, M.

    1972-01-01

    The energy, angular, and latitude distributions of energetic neutrons (up to 2 GeV) leaking from the top of the atmosphere have been calculated. The results agree with the recent measurement of Preszler, Simnett, and White, whose leakage rates were well above the calculation of Lingenfelter. Since the spectrum of Lingenfelter has served for evaluating the cosmic-ray albedo-neutron decay (CRAND) source of energetic protons in Earth's inner radiation belt, it is suggested that the results reported here be used to reevaluate the CRAND contribution.

  20. Towards aerial natural gas leak detection system based on TDLAS

    NASA Astrophysics Data System (ADS)

    Liu, Shuyang; Zhou, Tao; Jia, Xiaodong

    2014-11-01

    Pipeline leakage is a complex scenario for sensing system due to the traditional high cost, low efficient and labor intensive detection scheme. TDLAS has been widely accepted as industrial trace gas detection method and, thanks to its high accuracy and reasonable size, it has the potential to meet pipeline gas leakage detection requirements if it combines with the aerial platform. Based on literature study, this paper discussed the possibility of applying aerial TDLAS principle in pipeline gas leak detection and the key technical foundation of implementing it. Such system is able to result in a high efficiency and accuracy measurement which will provide sufficient data in time for the pipeline leakage detection.

  1. Spontaneous sphenoid sinus cerebrospinal fluid leak and meningoencephalocele – are they due to patent Sternberg's canal?

    PubMed Central

    Tomaszewska, Magdalena; Krzeski, Antoni

    2014-01-01

    Sternberg's canal is a congenital bony defect in the lateral wall of the sphenoid sinus. If it persists to adulthood, it may become a source of spontaneous cerebrospinal fluid leak (CSF) and meningoencephalocele. The aim of the study was to describe the authors’ experience and review articles related to spontaneous sphenoid sinus CSF leaks and Sternberg's canal. We analysed patients managed surgicallly due to sphenoid sinus CSF leak and performed a PubMed database search. Two female patients with spontaneous CSF leak of sphenoid origin were found. Both patients underwent surgery with the endoscopic endonasal approach, and the defect was closed using the multi-layer technique. Twelve articles related to CSF leaks of sphenoid origin (due to Sternberg's canal) were found in the PubMed database. Lines of lesser resistance within sphenoid bone may underlie CSF leak pathology together with intracranial hypertension. The endoscopic transnasal approach to the sphenoid sinus is an excellent alternative to standard transcranial procedures. PMID:26240642

  2. Chlyous leak after radical oesophagectomy: Thoracic duct lymphangiography and embolisation (TDE)—A case report

    PubMed Central

    Atie, M.; Dunn, G.; Falk, G.L.

    2016-01-01

    Introduction Chyle leak after oesophagectomy is highly morbid and may carry significant mortality if treatment is delayed. Identification of the site of leakage and surgery may be plagued by failure. Presentation of case We describe a case of chyle leak after oesophagectomy. Lymphangiography revealed the site of chyle leak to be an aberrant duct that would have been difficult to identify surgically. Radiological coiling and embolization successfully treated the leak. Discussion The gold standard for treatment of chyle leak or chylothorax after oesophagectomy was a re-operation, either open or throracoscopic, to ligate the thoracic duct. The interventional radiological technique employed in our case was not only efficacious in stopping the leak, but had the added advantage of identifying the site and highlighting the anatomy hence avoiding a morbid reoperation. The literature is reviewed. Conclusion The report and review confirm that lymphangiography followed by coiling and embolization for chylothorax post oesophagectomy is safe and effective in a majority of cases. PMID:27082992

  3. Natural Orifice Surgery (NOS) Using StomaphyX™ for Repair of Gastric Leaks after Bariatric Revisions

    PubMed Central

    2008-01-01

    Gastric leaks represent serious complications of bariatric surgery. With the increasing popularity and performance of bariatric procedures, the incidence of leaks and associated complications are expected to increase. Minimally invasive natural orifice surgery represents a novel and promising approach to gastric leak management, especially for morbidly obese patients who are at much higher risk from open or laparoscopic surgical procedures. The present article reports two cases of the safe and successful use of the EndoGastric Solutions StomaphyX™ device to alter the flow of gastric contents and repair gastric leaks resulting from bariatric revision surgery. Both patients were at a high risk and could not undergo another open or laparoscopic surgery to correct the leaks that were not healing. The StomaphyX procedures lasted approximately 30 min, were performed without any complications, and resulted in the resolution of the gastric leaks in both patients. PMID:18438622

  4. Quantitative risk assessment & leak detection criteria for a subsea oil export pipeline

    NASA Astrophysics Data System (ADS)

    Zhang, Fang-Yuan; Bai, Yong; Badaruddin, Mohd Fauzi; Tuty, Suhartodjo

    2009-06-01

    A quantitative risk assessment (QRA) based on leak detection criteria (LDC) for the design of a proposed subsea oil export pipeline is presented in this paper. The objective of this QRA/LDC study was to determine if current leak detection methodologies were sufficient, based on QRA results, while excluding the use of statistical leak detection; if not, an appropriate LDC for the leak detection system would need to be established. The famous UK PARLOC database was used for the calculation of pipeline failure rates, and the software POSVCM from MMS was used for oil spill simulations. QRA results revealed that the installation of a statistically based leak detection system (LDS) can significantly reduce time to leak detection, thereby mitigating the consequences of leakage. A sound LDC has been defined based on QRA study results and comments from various LDS vendors to assist the emergency response team (ERT) to quickly identify and locate leakage and employ the most effective measures to contain damage.

  5. Spontaneous sphenoid sinus cerebrospinal fluid leak and meningoencephalocele - are they due to patent Sternberg's canal?

    PubMed

    Tomaszewska, Magdalena; Brożek-Mądry, Eliza; Krzeski, Antoni

    2015-07-01

    Sternberg's canal is a congenital bony defect in the lateral wall of the sphenoid sinus. If it persists to adulthood, it may become a source of spontaneous cerebrospinal fluid leak (CSF) and meningoencephalocele. The aim of the study was to describe the authors' experience and review articles related to spontaneous sphenoid sinus CSF leaks and Sternberg's canal. We analysed patients managed surgicallly due to sphenoid sinus CSF leak and performed a PubMed database search. Two female patients with spontaneous CSF leak of sphenoid origin were found. Both patients underwent surgery with the endoscopic endonasal approach, and the defect was closed using the multi-layer technique. Twelve articles related to CSF leaks of sphenoid origin (due to Sternberg's canal) were found in the PubMed database. Lines of lesser resistance within sphenoid bone may underlie CSF leak pathology together with intracranial hypertension. The endoscopic transnasal approach to the sphenoid sinus is an excellent alternative to standard transcranial procedures. PMID:26240642

  6. Spontaneous sphenoid sinus cerebrospinal fluid leak and meningoencephalocele - are they due to patent Sternberg's canal?

    PubMed

    Tomaszewska, Magdalena; Brożek-Mądry, Eliza; Krzeski, Antoni

    2015-07-01

    Sternberg's canal is a congenital bony defect in the lateral wall of the sphenoid sinus. If it persists to adulthood, it may become a source of spontaneous cerebrospinal fluid leak (CSF) and meningoencephalocele. The aim of the study was to describe the authors' experience and review articles related to spontaneous sphenoid sinus CSF leaks and Sternberg's canal. We analysed patients managed surgicallly due to sphenoid sinus CSF leak and performed a PubMed database search. Two female patients with spontaneous CSF leak of sphenoid origin were found. Both patients underwent surgery with the endoscopic endonasal approach, and the defect was closed using the multi-layer technique. Twelve articles related to CSF leaks of sphenoid origin (due to Sternberg's canal) were found in the PubMed database. Lines of lesser resistance within sphenoid bone may underlie CSF leak pathology together with intracranial hypertension. The endoscopic transnasal approach to the sphenoid sinus is an excellent alternative to standard transcranial procedures.

  7. How to locate and treat lymph leaks using patent blue V dye and Floseal.

    PubMed

    Choong, Andrew M T L; Alagaratnam, Swethan; Floyd, David; Al-Dubaisi, Muhamed; Loh, Alexander

    2014-02-01

    Lymph leaks after vascular groin dissections can be a challenging postoperative complication for both patient and surgeon. A multidisciplinary team at a district general hospital in the United Kingdom consisting of breast, plastic, and vascular surgeons performed intraoperative lymphatic mapping using patent blue V dye to locate the exact location of a groin lymph leak before sealing the leak with direct vision ligation and Floseal Hemostatic Matrix (Baxter Healthcare Corp., Hayward, CA).

  8. Hanford Single Shell Tank Leak Causes and Locations - 241-TX Farm

    SciTech Connect

    Girardot, C. L.; Harlow, D> G.

    2014-07-22

    This document identifies 241-TX Tank Farm (TX Farm) leak causes and locations for the 100 series leaking tanks (241-TX-107 and 241-TX-114) identified in RPP-RPT-50870, Rev. 0, Hanford 241-TX Farm Leak Inventory Assessment Report. This document satisfies the TX Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  9. Hanford Single-Shell Tank Leak Causes and Locations - 241-A Farm

    SciTech Connect

    Girardot, Crystal L.; Harlow, Donald G.

    2013-09-10

    This document identifies 241-A Tank Farm (A Farm) leak causes and locations for the 100 series leaking tanks (241-A-104 and 241-A-105) identified in RPP-ENV-37956, Hanford A and AX Farm Leak Assessment Report. This document satisfies the A Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  10. Hanford Single-Shell Tank Leak Causes and Locations - 241-C Farm

    SciTech Connect

    Girardot, Crystal L.; Harlow, Donald G.

    2013-07-30

    This document identifies 241-C Tank Farm (C Farm) leak causes and locations for the 100 series leaking tanks (241-C-101 and 241-C-105) identified in RPP-RPT-33418, Rev. 2, Hanford C-Farm Leak Inventory Assessments Report. This document satisfies the C Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  11. Chyle leak following right axillary lymph node dissection: A case report and review of current literature

    PubMed Central

    Daggett, J.D.; Watt, A.W.; Smith, P.D.

    2016-01-01

    This report discusses the case of a chyle leak following a right axillary lymph node dissection for breast cancer. This presented as a sudden change in drainage character from a right axillary surgical drain from serous to milky white shortly after restarting a diet. The diagnosis of chyle leak was confirmed by laboratory testing of the fluid and managed with closed suction drainage. Chyle leak is a rare, but increasingly recognized complication following axillary clearance for breast cancer and melanoma. PMID:26826928

  12. Air leaking through the mouth during nocturnal nasal ventilation: effect on sleep quality.

    PubMed

    Meyer, T J; Pressman, M R; Benditt, J; McCool, F D; Millman, R P; Natarajan, R; Hill, N S

    1997-07-01

    Air leaking through the mouth has been reported in kyphoscoliotic patients receiving nasal ventilation via volume-limited ventilators. This study accessed the frequency of occurrence and effect on sleep quality of air leaking through the mouth during nocturnal nasal ventilation in patients with chest wall and neuromuscular disease using pressure-limited ventilation. Overnight and daytime polysomnography was performed in six stable experienced users of nocturnal nasal noninvasive positive-pressure ventilation (NPPV) who had chronic respiratory failure due to neuromuscular disease or chest wall deformity. All patients used the BiPAP S/T-D ventilatory support system (Respironics, Inc., Murrysville, PA). Measures included sleep scoring, leak quantitation, diaphragm and submental electromyograms (EMGs), and tidal and leak volumes. All patients had air leaking through the mouth for the majority of sleep. Sleep quality was diminished because of poor sleep efficiency and reduced percentages of slow-wave and rapid eye movement (REM) sleep. Air leaking through the mouth was associated with frequent arousals during stages 1 and 2 and REM sleep that contributed to sleep fragmentation, but arousals were infrequent during slow-wave sleep. Despite prevalent leaking, oxygenation was well maintained in all but one patient. Patients used a-combination of passive and active mechanisms to control air leaking. Although nasal ventilation improves nocturnal hypoventilation and symptoms in patients with restrictive thoracic disorders, air leaking through the mouth is very common during use. The leaking is associated with frequent arousals during lighter stages of sleep that interfere with progression to deeper stages, compromising sleep quality. Portable pressure-limited ventilators compensate for leaks, maintaining ventilation and oxygenation, but further studies are needed to determine which interfaces and ventilator techniques best control air leaking and optimize sleep quality.

  13. 46 CFR 38.15-10 - Leak detection systems-T/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Leak detection systems-T/ALL. 38.15-10 Section 38.15-10... Requirements § 38.15-10 Leak detection systems—T/ALL. (a) A detection system shall be permanently installed to sense cargo leaks. The detectors shall be located within the space so as to permit the sensing of...

  14. 46 CFR 38.15-10 - Leak detection systems-T/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Leak detection systems-T/ALL. 38.15-10 Section 38.15-10... Requirements § 38.15-10 Leak detection systems—T/ALL. (a) A detection system shall be permanently installed to sense cargo leaks. The detectors shall be located within the space so as to permit the sensing of...

  15. 46 CFR 38.15-10 - Leak detection systems-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Leak detection systems-T/ALL. 38.15-10 Section 38.15-10... Requirements § 38.15-10 Leak detection systems—T/ALL. (a) A detection system shall be permanently installed to sense cargo leaks. The detectors shall be located within the space so as to permit the sensing of...

  16. 46 CFR 38.15-10 - Leak detection systems-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Leak detection systems-T/ALL. 38.15-10 Section 38.15-10... Requirements § 38.15-10 Leak detection systems—T/ALL. (a) A detection system shall be permanently installed to sense cargo leaks. The detectors shall be located within the space so as to permit the sensing of...

  17. Hanford Single-Shell Tank Leak Causes and Locations - 241-U Farm

    SciTech Connect

    Girardot, Crystal L.; Harlow, Donald G.

    2013-12-02

    This document identifies 241-U Tank Farm (U Farm) leak causes and locations for the 100 series leaking tanks (241-U-104, 241-U-110, and 241-U-112) identified in RPP-RPT-50097, Rev. 0, Hanford 241-U Farm Leak Inventory Assessment Report. This document satisfies the U-Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  18. Hanford Single-Shell Tank Leak Causes and Locations - 241-T Farm

    SciTech Connect

    Girardot, Crystal L.; Harlow, Donald G.

    2014-05-15

    This document identifies 241-T Tank Farm (T Farm) leak causes and locations for the 100 series leaking tanks (241-T-106 and 241-T-111) identified in RPP-RPT-55084, Rev. 0, Hanford 241-T Farm Leak Inventory Assessment Report. This document satisfies the T Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  19. Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm

    SciTech Connect

    Girardot, Crystal L.; Harlow, Donald G.

    2013-11-19

    This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) leak causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105, and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

  20. Development of a General Method for Determining Leak Rates from Limiting Enclosures

    NASA Technical Reports Server (NTRS)

    Zografos, A. I.; Blackwell, C. C.; Harper, Lynn D. (Technical Monitor)

    1994-01-01

    This paper discusses the development of a general method for the determination of very low leak rates from limiting enclosures. There are many methods that can be used to detect and repair leaks from enclosures. Many methods have also been proposed that allow the estimation of actual leak rates, usually expressed as enclosure volume turnover. The proposed method combines measurements of the state variables (pressure, temperature, and volume) as well as the change in the concentration of a tracer gas to estimate the leak rate. The method was applied to the containment enclosure of the Engineering Development Unit of the CELSS Test Facility, currently undergoing testing at the NASA Ames Research Center.

  1. Phylogenetic differences of mammalian basal metabolic rate are not explained by mitochondrial basal proton leak

    PubMed Central

    Polymeropoulos, E. T.; Heldmaier, G.; Frappell, P. B.; McAllan, B. M.; Withers, K. W.; Klingenspor, M.; White, C. R.; Jastroch, M.

    2012-01-01

    Metabolic rates of mammals presumably increased during the evolution of endothermy, but molecular and cellular mechanisms underlying basal metabolic rate (BMR) are still not understood. It has been established that mitochondrial basal proton leak contributes significantly to BMR. Comparative studies among a diversity of eutherian mammals showed that BMR correlates with body mass and proton leak. Here, we studied BMR and mitochondrial basal proton leak in liver of various marsupial species. Surprisingly, we found that the mitochondrial proton leak was greater in marsupials than in eutherians, although marsupials have lower BMRs. To verify our finding, we kept similar-sized individuals of a marsupial opossum (Monodelphis domestica) and a eutherian rodent (Mesocricetus auratus) species under identical conditions, and directly compared BMR and basal proton leak. We confirmed an approximately 40 per cent lower mass specific BMR in the opossum although its proton leak was significantly higher (approx. 60%). We demonstrate that the increase in BMR during eutherian evolution is not based on a general increase in the mitochondrial proton leak, although there is a similar allometric relationship of proton leak and BMR within mammalian groups. The difference in proton leak between endothermic groups may assist in elucidating distinct metabolic and habitat requirements that have evolved during mammalian divergence. PMID:21632624

  2. Ultra high vacuum pumping system and high sensitivity helium leak detector

    DOEpatents

    Myneni, G.R.

    1997-12-30

    An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10{sup {minus}13} atm cc/s. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces back streaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium. 2 figs.

  3. Ultra high vacuum pumping system and high sensitivity helium leak detector

    DOEpatents

    Myneni, Ganapati Rao

    1997-01-01

    An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.

  4. Location and repair of air leaks in the ATF (Advanced Toroidal Facility) vacuum vessel

    SciTech Connect

    Schwenterly, S.W.; Gabbard, W.A.; Schaich, C.R.; Yarber, J.L. )

    1989-01-01

    On the basis of partial pressure rate-of-rise and base pressure measurements, it was determined that the Advanced Toroidal Facility (ATF) vacuum vessel had an air leak in the low 10{sup -4} mbar-{ell}/s range. Pinpointing this leak by conventional helium leak-checking procedures was not possible, because large portions of the outside of the vessel are covered by the helcial field coils and a structural shell. Various alternative leak-detection schemes that were considered are summarized and their advantages and disadvantages noted. In the method ultimately employed, gun-rubber patches of various sizes ranging from 12.7 by 12.7 cm to 20.3 by 30.5 cm were positioned on the inside surfaces of the vessel and evacuated by the leak detector (LD). After roughly 5% of the surface was inspected in this way, a leak of > 10{sup -5} mbar-{ell}/s was discovered and localized to an area of 5 by 5 cm. Dye penetrant applied to this area disclosed three pinholes. Two small slag pockets were discovered while these points were being ground out. After these were rewelded, no furthered leakage could be found in the repaired area. Global leak rates measured after the machine was reevacuated indicated that this leak was about 30% of the overall leak rate. 1 ref., 5 figs., 1 tab.

  5. Detection of leaks in buried rural water pipelines using thermal infrared images

    USGS Publications Warehouse

    Eidenshink, Jeffery C.

    1985-01-01

    Leakage is a major problem in many pipelines. Minor leaks called 'seeper leaks', which generally range from 2 to 10 m3 per day, are common and are difficult to detect using conventional ground surveys. The objective of this research was to determine whether airborne thermal-infrared remote sensing could be used in detecting leaks and monitoring rural water pipelines. This study indicates that such leaks can be detected using low-altitude 8.7- to 11.5. micrometer wavelength, thermal infrared images collected under proper conditions.

  6. Sellar Reconstruction and Rates of Delayed Cerebrospinal Fluid Leak after Endoscopic Pituitary Surgery

    PubMed Central

    Sanders-Taylor, Chris; Anaizi, Amjad; Kosty, Jennifer; Zimmer, Lee A.; Theodosopoulos, Phillip V.

    2015-01-01

    Objectives Delayed cerebrospinal fluid (CSF) leaks are a complication in transsphenoidal surgery, potentially causing morbidity and longer hospital stays. Sella reconstruction can limit this complication, but is it necessary in all patients? Design Retrospective review. Setting Single-surgeon team (2005–2012) addresses this trend toward graded reconstruction. Participants A total of 264 consecutive patients with pituitary adenomas underwent endoscopic transsphenoidal resections. Sellar defects sizable to accommodate a fat graft were reconstructed. Main outcomes Delayed CSF leak and autograft harvesting. Results Overall, 235 (89%) had reconstruction with autograft (abdominal fat, septal bone/cartilage) and biological glue. Delayed CSF leak was 1.9%: 1.7%, and 3.4% for reconstructed and nonreconstructed sellar defects, respectively (p = 0.44). Complications included one reoperation for leak, two developed meningitis, and autograft harvesting resulted in abdominal hematoma in 0.9% and wound infection in 0.4%. Conclusion In our patients, delayed CSF leaks likely resulted from missed intraoperative CSF leaks or postoperative changes. Universal sellar reconstruction can preemptively treat missed leaks and provide a barrier for postoperative changes. When delayed CSF leaks occurred, sellar reconstruction often allowed for conservative treatment (i.e., lumbar drain) without repeat surgery. We found universal reconstruction provides a low risk of delayed CSF leak with minimal complications. PMID:26225317

  7. Method of locating a leaking fuel element in a fast breeder power reactor

    DOEpatents

    Honekamp, John R.; Fryer, Richard M.

    1978-01-01

    Leaking fuel elements in a fast reactor are identified by measuring the ratio of .sup.134 Xe to .sup.133 Xe in the reactor cover gas following detection of a fuel element leak, this ratio being indicative of the power and burnup of the failed fuel element. This procedure can be used to identify leaking fuel elements in a power breeder reactor while continuing operation of the reactor since the ratio measured is that of the gases stored in the plenum of the failed fuel element. Thus, use of a cleanup system for the cover gas makes it possible to identify sequentially a multiplicity of leaking fuel elements without shutting the reactor down.

  8. A Cranial-Sided Approach for Repeated Mitral Periprosthetic Leak After Right Pneumonectomy.

    PubMed

    Takahashi, Yosuke; Shibata, Toshihiko; Sasaki, Yasuyuki; Kato, Yasuyuki; Motoki, Manabu; Morisaki, Akimasa; Nishimura, Shinsuke; Hattori, Koji

    2016-03-01

    A 72-year-old man presented with worsening dyspnea on effort. He underwent right pneumonectomy 40 years ago, then mitral valve replacement through a right thoracotomy 8 years ago with repeat surgery to repair a periprosthetic valve leak; the mediastinum was displaced to the right, and the heart was rotated counterclockwise. Transthoracic echocardiography showed periprosthetic valve leak recurrence near the left atrial appendage. We repaired the periprosthetic valve leak through a median sternotomy. Transecting the main pulmonary artery allowed us to widely open the cranial-sided left atrium. We obtained good exposure of the mitral valve, and repaired the periprosthetic valve leak using pledgeted sutures and a pericardial patch.

  9. Leak Locating Experiment for Actual Underground Water Supply Pipelines with a Novel Locating System

    NASA Astrophysics Data System (ADS)

    Lee, Young-Sup; Yoon, Dong-Jin; Kang, Seokhoon; Jun, Kyungkoo; Choi, Byoungjo

    This paper presents a novel leak locating system to identify precise position of leak spots of underground water supply pipelines. The system has been studied and developed upon excellent foundation with modern mobile communication technology and the internet. However, the leak locating algorithm in the new system requires knowing the exact acoustical wave speed inside water-filled pipelines and the accurate time arrival difference between sensors to detect precise leak location. Especially the time difference is calculated with optimal maximum likelihood method. For the demonstration of the new system, an intensive experiment performed with 315 m long actual underground water supply pipelines showed an excellent detection capability.

  10. Adiponectin protects against hyperoxic lung injury and vascular leak

    PubMed Central

    Sliman, Sean M.; Patel, Rishi B.; Cruff, Jason P.; Kotha, Sainath R.; Newland, Christie A.; Schrader, Carrie A.; Sherwani, Shariq I.; Gurney, Travis O.; Magalang, Ulysses J.; Parinandi, Narasimham L.

    2014-01-01

    Adiponectin (Ad), an adipokine exclusively secreted by the adipose tissue, has emerged as a paracrine metabolic regulator as well as a protectant against oxidative stress. Pharmacological approaches of protecting against clinical hyperoxic lung injury during oxygen therapy/treatment are limited. Earlier, we have reported that Ad inhibits the NADPH oxidase-catalyzed formation of superoxide from molecular oxygen in human neutrophils. Having this as the premise, we conducted studies to determine whether (i) exogenous Ad would protect against the hyperoxia-induced barrier dysfunction in the lung endothelial cells (ECs) in vitro and (ii) endogenously synthesized Ad would protect against hyperoxic lung injury in wild type (WT) and Ad-overexpressing transgenic (AdTg) mice in vivo. The results demonstrated that exogenous Ad protected against the hyperoxia-induced oxidative stress, loss of glutathione (GSH), cytoskeletal reorganization, barrier dysfunction, and leak in the lung ECs in vitro. Furthermore, the hyperoxia-induced lung injury, vascular leak, and lipid peroxidation were significantly attenuated in AdTg mice in vivo. Also, AdTg mice exhibited elevated levels of total thiols and GSH in the lungs as compared to WT mice. For the first time, our studies demonstrated that Ad protected against the hyperoxia-induced lung damage apparently through attenuation of oxidative stress and modulation of thiol-redox status. PMID:22183615

  11. Chauncey Leake and the development of bioethics in America.

    PubMed

    Brody, Howard

    2014-03-01

    Chauncey D. Leake (1896-1978) occupies a unique place in the history of American bioethics. A pharmacologist, he was largely an autodidact in both history and philosophy, and believed that ethics should ideally be taught to medical students by those with philosophical training. After pioneering work on medical ethics during the 1920s, he helped to lay the groundwork for important centers for bioethics and medical humanities at two institutions where he worked, the University of California-San Francisco and the University of Texas Medical Branch-Galveston. Understanding Leake's role in American bioethics requires navigating a number of paradoxes--why he was described respectfully in his time but largely forgotten today; how in the 1920s he could write forward-looking pieces that anticipated many of the themes taken up by bioethics a half-century later, yet played largely a reactionary role when the new bioethics actually arrived; and why he advocated turning to philosophy and philosophers for a proper understanding of ethics, yet appeared often to misunderstand philosophical ethics.

  12. Non-linear leak currents affect mammalian neuron physiology

    PubMed Central

    Huang, Shiwei; Hong, Sungho; De Schutter, Erik

    2015-01-01

    In their seminal works on squid giant axons, Hodgkin, and Huxley approximated the membrane leak current as Ohmic, i.e., linear, since in their preparation, sub-threshold current rectification due to the influence of ionic concentration is negligible. Most studies on mammalian neurons have made the same, largely untested, assumption. Here we show that the membrane time constant and input resistance of mammalian neurons (when other major voltage-sensitive and ligand-gated ionic currents are discounted) varies non-linearly with membrane voltage, following the prediction of a Goldman-Hodgkin-Katz-based passive membrane model. The model predicts that under such conditions, the time constant/input resistance-voltage relationship will linearize if the concentration differences across the cell membrane are reduced. These properties were observed in patch-clamp recordings of cerebellar Purkinje neurons (in the presence of pharmacological blockers of other background ionic currents) and were more prominent in the sub-threshold region of the membrane potential. Model simulations showed that the non-linear leak affects voltage-clamp recordings and reduces temporal summation of excitatory synaptic input. Together, our results demonstrate the importance of trans-membrane ionic concentration in defining the functional properties of the passive membrane in mammalian neurons as well as other excitable cells. PMID:26594148

  13. Digital radar-gram processing for water pipelines leak detection

    NASA Astrophysics Data System (ADS)

    García-Márquez, Jorge; Flores, Ricardo; Valdivia, Ricardo; Carreón, Dora; Malacara, Zacarías; Camposeco, Arturo

    2006-02-01

    Ground penetrating radars (GPR) are useful underground exploration devices. Applications are found in archaeology, mine detection, pavement evaluation, among others. Here we use a GPR to detect by an indirect way, the anomalies caused by the presence of water in the neighborhood of an underground water pipeline. By Fourier transforming a GPR profile map we interpret the signal as spatial frequencies, instead of the temporal frequencies, that composes the profile map. This allows differentiating between signals returning from a standard subsoil feature from those coming back from anomalous zones. Facilities in Mexican cities are commonly buried up to 2.5 m. Their constituent materials are PVC, concrete or metal, typically steel. GPRs are ultra-wide band devices; leak detection must be an indirect process since echoes due to the presence of underground zones with high moisture levels are masked by dense reflections (clutter). In radargrams the presence of water is visualized as anomalies in the neighborhood of the facility. Enhancement of these anomalies will give us the information required to detect leaks.

  14. Stand-alone sensors monitor for combustible gas leaks

    SciTech Connect

    Not Available

    1991-01-01

    Elizabeth Gas Co., a gas distribution company in New Jersey, has added a network of combustible gas sensors to a computer system already in place for continuous monitoring of gas leaks. The computer center at the company's Erie St. facility controls all dispatching, which includes routing gas through the system and controlling gas pressure. The system uses redundant Hewlett-Packard A900 central processing units (CPU), 6 monitors, including a Mitsubishi 35-in. color monitor, and Fisher control software. The company's primary tank farm, which contains over a million gallons of propane and LNG, is located near several chemical plants, an oil refinery and a residential neighborhood. To monitor for combustible leaks at the site, the company installed 49 stand-alone combustible gas sensors manufactured by Mine Safety Appliances Co. (MSA) of Pittsburgh, Pa. The sensors are designed to measure the concentrations of propane and LNG and trigger alarms at 20% of the lower explosive limit (LEL). The sensors are diffusion types that sample ambient air rather than drawing in samples through a pump. Using the principle of catalytic oxidation, the sensors produce a signal proportional to the concentration of combustible gas in the atmosphere. If gas is detected above 20% of the LEL, a relay driver signal is sent into a remote annunciator panel which contains LED alarm displays for each sensor. The remote annunciator panel also houses a 24 VDC power supply.

  15. Conservatism on current leak-before-break application

    SciTech Connect

    Yu, Y.J.; Kim, J.H.; Park, S.H.; Kim, Y.J.

    1995-12-01

    Currently, LBB (Leak Before Break) analysis is performed in accordance with the NUREG 1061 Vol. 3. According to NUREG 1061 Vol. 3, it is necessary to hypothesize the leakage crack at critical locations of a piping system. The leakage crack length is calculated by applying a margin of 10 on the capability of the plant leak detection system. Then the stability of the cracked pipe must be assured for normal plus SSE(Safe Shutdown Earthquake) loads at twice the leakage crack length, and {radical}2 times the sum of normal plus SSE loads at the leakage crack length. This current LBB criteria is very conservative. In this paper, the results of various studies are presented to demonstrate the conservatism on the current LBB application. The studies are focused on the plant in service inspection program, fatigue crack growth behavior of the crack, elastic plastic behavior of the cracked pipe considering entire piping geometry and also focused on the collection of material test data. In conclusion, it is demonstrated that some level of margins already exist in the standard LBB analysis method. Therefore, the margins specified in the NUREG 1061 Vol.3 could be relaxed to extend LBB application to the smaller diameter pipe.

  16. Blowdown transients and implication for leak protection shutdown strategy

    SciTech Connect

    Magee, P M

    1980-04-01

    The creep-fatigue damage due to a blowdown transient is independent of the rate of water-side blowdown following isolation. The damage depends primarily upon plant system characteristics which set the rate of IHTS sodium cooldown after reactor scram and main pump trip. The time delay between a small leak alarm and reactor scram should be considered as a tradeoff between (1) providing time to confirm the existence of the leak to a reasonable level of assurance and (2) the potential for secondary tube wastage damage. In general, there appears to be no incentive to delay water-side blowdown following scram because the additional stress damage due to blowdown is insignificant and the potential for wastage damage should be eliminated as quickly as possible. One exception is the case of multiple evaporators feeding a superheater (as for CRBRP) where isolation and blowdown of one evaporator shortly after scram can cause significant additional stress damage to the superheater upper tubesheet. When initiated, the water-side blowdown process should be rapid. About 30 seconds blowdown time appears practical and adequate, based on the CRBRP design.

  17. You won`t find these leaks with a blower door: The latest in {open_quotes}leaking electricity{close_quotes} in homes

    SciTech Connect

    Rainer, L.; Greenberg, S.; Meier, A.

    1996-08-01

    Leaking electricity is the energy consumed by appliances when they are switched off or not performing their principal functions. Field measurements in Florida, California, and Japan show that leaking electricity represents 50 to 100 Watts in typical homes, corresponding to about 5 GW of total electricity demand in the United States. There are three strategies to reduce leaking electricity: eliminate leakage entirely, eliminate constant leakage and replace with intermittent charge plus storage, and improve efficiency of conversion. These options are constrained by the low value of energy savings-less than $5 per saved Watt. Some technical and lifestyle solutions are proposed. 13 refs., 1 fig., 2 tabs.

  18. Biphasic decay of the Ca transient results from increased sarcoplasmic reticulum Ca leak

    PubMed Central

    Sankaranarayanan, Rajiv; Li, Yatong; Greensmith, David J.; Eisner, David A.

    2016-01-01

    Key points Ca leak from the sarcoplasmic reticulum through the ryanodine receptor (RyR) reduces the amplitude of the Ca transient and slows its rate of decay.In the presence of β‐adrenergic stimulation, RyR‐mediated Ca leak produces a biphasic decay of the Ca transient with a fast early phase and a slow late phase.Two forms of Ca leak have been studied, Ca‐sensitising (induced by caffeine) and non‐sensitising (induced by ryanodine) and both induce biphasic decay of the Ca transient.Only Ca‐sensitising leak can be reversed by traditional RyR inhibitors such as tetracaine.Ca leak can also induce Ca waves. At low levels of leak, waves occur. As leak is increased, first biphasic decay and then slowed monophasic decay is seen. The level of leak has major effects on the shape of the Ca transient. Abstract In heart failure, a reduction in Ca transient amplitude and contractile dysfunction can by caused by Ca leak through the sarcoplasmic reticulum (SR) Ca channel (ryanodine receptor, RyR) and/or decreased activity of the SR Ca ATPase (SERCA). We have characterised the effects of two forms of Ca leak (Ca‐sensitising and non‐sensitising) on calcium cycling and compared with those of SERCA inhibition. We measured [Ca2+]i with fluo‐3 in voltage‐clamped rat ventricular myocytes. Increasing SR leak with either caffeine (to sensitise the RyR to Ca activation) or ryanodine (non‐sensitising) had similar effects to SERCA inhibition: decreased systolic [Ca2+]i, increased diastolic [Ca2+]i and slowed decay. However, in the presence of isoproterenol, leak produced a biphasic decay of the Ca transient in the majority of cells while SERCA inhibition produced monophasic decay. Tetracaine reversed the effects of caffeine but not of ryanodine. When caffeine (1 mmol l−1) was added to a cell which displayed Ca waves, the wave frequency initially increased before waves disappeared and biphasic decay developed. Eventually (at higher caffeine concentrations), the

  19. Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine

    NASA Technical Reports Server (NTRS)

    Schwabacher, Mark A.; Aguilar, Robert; Figueroa, Fernando F.

    2009-01-01

    The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.

  20. Air pollutant penetration through airflow leaks into buildings

    SciTech Connect

    Liu, De-Ling

    2002-09-01

    The penetration of ambient air pollutants into the indoor environment is of concern owing to several factors: (1) epidemiological studies have shown a strong association between ambient fine particulate pollution and elevated risk of human mortality; (2) people spend most of their time in indoor environments; and (3) most information about air pollutant concentration is only available from ambient routine monitoring networks. A good understanding of ambient air pollutant transport from source to receptor requires knowledge about pollutant penetration across building envelopes. Therefore, it is essential to gain insight into particle penetration in infiltrating air and the factors that affect it in order to assess human exposure more accurately, and to further prevent adverse human health effects from ambient particulate pollution. In this dissertation, the understanding of air pollutant infiltration across leaks in the building envelope was advanced by performing modeling predictions as well as experimental investigations. The modeling analyses quantified the extent of airborne particle and reactive gas (e.g., ozone) penetration through building cracks and wall cavities using engineering analysis that incorporates existing information on building leakage characteristics, knowledge of pollutant transport processes, as well as pollutant-surface interactions. Particle penetration is primarily governed by particle diameter and by the smallest dimension of the building cracks. Particles of 0.1-1 {micro}m are predicted to have the highest penetration efficiency, nearly unity for crack heights of 0.25 mm or higher, assuming a pressure differential of 4 Pa or greater and a flow path length of 3 cm or less. Supermicron and ultrafine particles (less than 0.1 {micro}m) are readily deposited on crack surfaces by means of gravitational settling and Brownian diffusion, respectively. The fraction of ozone penetration through building leaks could vary widely, depending

  1. Field Demonstration of Innovative Condition Assessment Technologies for Water Mains: Leak Detection and Location

    EPA Science Inventory

    Three leak detection/location technologies were demonstrated on a 76-year-old, 2,057-ft-long portion of a cement-lined, 24-in. cast iron water main in Louisville, KY. This activity was part of a series of field demonstrations of innovative leak detection/location and condition a...

  2. A HYBRID THERMAL VIDEO AND FTTR SPECTROMETER FOR RAPIDLY LOCATING AND CHARACTERIZING GAS LEAKS

    EPA Science Inventory

    Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality as well as being a public health problem. Surveying a facility for potential gas leaks can be a daunting task. An efficient, accurate and cost-effecti...

  3. 46 CFR 38.15-10 - Leak detection systems-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Leak detection systems-T/ALL. 38.15-10 Section 38.15-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS LIQUEFIED FLAMMABLE GASES Special Requirements § 38.15-10 Leak detection systems—T/ALL. (a) A detection system shall be permanently installed...

  4. Contribution of mitochondrial proton leak to skeletal muscle respiration and to standard metabolic rate.

    PubMed

    Rolfe, D F; Brand, M D

    1996-10-01

    We have tested the hypothesis that the leak of protons across the mitochondrial inner membrane (proton leak) is a significant contributor to standard metabolic rate (SMR). We found that proton leak accounts for around one-half of the resting respiration rate of perfused rat skeletal muscle. Proton leak is known to make a significant (26%) contribution to the resting respiration rate of isolated rat hepatocytes (M. D. Brand, L.-F. Chien, E. K. Ainscow, D. F. S. Rolfe, and R. K. Porter. Biochim. Biophys. Acta 1187: 132-139, 1994). If the importance of proton leak in these isolated and perfused systems is similar to its importance in vivo, then using literature values for the contribution of liver and skeletal muscle to SMR, we can calculate that proton leak in liver and skeletal muscle alone accounts for 11-26% (mean 20%) of the SMR of the rat. If proton leak activity in the other tissues of the rat is similar to that in liver cells, then the contribution of proton leak to rat SMR would be 16-31% (mean 25%).

  5. 10 CFR 34.27 - Leak testing and replacement of sealed sources.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Nuclear Regulatory Commission's Regional Office listed in appendix D of 10 CFR part 20 of this chapter... 10 Energy 1 2012-01-01 2012-01-01 false Leak testing and replacement of sealed sources. 34.27... SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and...

  6. 40 CFR 63.8015 - What requirements apply to my equipment leaks?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... manufacturing affected source subject to 40 CFR part 63, subpart HHHHH” shall apply for the purposes of this... equipment leaks? 63.8015 Section 63.8015 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... apply to my equipment leaks? (a) You must meet each requirement in Table 3 to this subpart that...

  7. 10 CFR 34.27 - Leak testing and replacement of sealed sources.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Nuclear Regulatory Commission's Regional Office listed in appendix D of 10 CFR part 20 of this chapter... 10 Energy 1 2014-01-01 2014-01-01 false Leak testing and replacement of sealed sources. 34.27... SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and...

  8. 40 CFR 63.1107 - Equipment leaks: applicability assessment procedures and methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 CFR part 60, appendix A shall be used. (b) An owner or operator may use good engineering judgment... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Equipment leaks: applicability... Categories: Generic Maximum Achievable Control Technology Standards § 63.1107 Equipment leaks:...

  9. 10 CFR 34.27 - Leak testing and replacement of sealed sources.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Nuclear Regulatory Commission's Regional Office listed in appendix D of 10 CFR part 20 of this chapter... 10 Energy 1 2011-01-01 2011-01-01 false Leak testing and replacement of sealed sources. 34.27... SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and...

  10. 40 CFR 63.8015 - What requirements apply to my equipment leaks?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manufacturing affected source subject to 40 CFR part 63, subpart HHHHH” shall apply for the purposes of this... leaks? 63.8015 Section 63.8015 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... my equipment leaks? (a) You must meet each requirement in Table 3 to this subpart that applies...

  11. 40 CFR 63.8015 - What requirements apply to my equipment leaks?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... manufacturing affected source subject to 40 CFR part 63, subpart HHHHH” shall apply for the purposes of this... equipment leaks? 63.8015 Section 63.8015 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... apply to my equipment leaks? (a) You must meet each requirement in Table 3 to this subpart that...

  12. 40 CFR 63.8015 - What requirements apply to my equipment leaks?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manufacturing affected source subject to 40 CFR part 63, subpart HHHHH” shall apply for the purposes of this... equipment leaks? 63.8015 Section 63.8015 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... apply to my equipment leaks? (a) You must meet each requirement in Table 3 to this subpart that...

  13. 40 CFR 63.1107 - Equipment leaks: applicability assessment procedures and methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 CFR part 60, appendix A shall be used. (b) An owner or operator may use good engineering judgment... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Equipment leaks: applicability... Categories: Generic Maximum Achievable Control Technology Standards § 63.1107 Equipment leaks:...

  14. 40 CFR 63.1107 - Equipment leaks: applicability assessment procedures and methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 CFR part 60, appendix A shall be used. (b) An owner or operator may use good engineering judgment... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Equipment leaks: applicability... Categories: Generic Maximum Achievable Control Technology Standards § 63.1107 Equipment leaks:...

  15. 40 CFR 63.8015 - What requirements apply to my equipment leaks?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manufacturing affected source subject to 40 CFR part 63, subpart HHHHH” shall apply for the purposes of this... equipment leaks? 63.8015 Section 63.8015 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... apply to my equipment leaks? (a) You must meet each requirement in Table 3 to this subpart that...

  16. Potential role of infrared imaging for detecting facial seal leaks in filtering facepiece respirator users.

    PubMed

    Harber, Philip; Su, Jing; Badilla, Alejandro D; Rahimian, Rombod; Lansey, Kirsten R

    2015-01-01

    Infrared imaging (IRI) can detect airflow through and near respirator masks based upon temperature differences between ambient and exhaled air. This study investigated the potential usefulness of IRI for detecting leaks and providing insight into the sites and significance of leaks. Subjects (n = 165) used filtering facepiece N95 respirators (N95 FFR) in the course of a research study concerning training modalities. Short sequence video infrared images were obtained during use and with intentionally introduced facial seal leaks. Fit factor (FF) was measured with condensation nuclei count methods. IRI detected leaks were scored on a four-point scale and summarized as the Total Leak Score (TLS) over six coding regions and the presence or absence of a "Big Leak" (BL) in any location. A semi-automated interpretation algorithm was also developed. IRI detected leaks are particularly common in the nasal region, but these are of limited significance. IR imaging could effectively identify many large leaks. The TLS was related to FF. Although IRI scores were related to FF, the relationship is insufficiently close for IRI to substitute for quantitative fit-testing. Using FFRs infrared techniques have potential for identifying situations with very inadequate respiratory protection.

  17. 40 CFR 63.1107 - Equipment leaks: applicability assessment procedures and methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 CFR part 60, appendix A shall be used. (b) An owner or operator may use good engineering judgment... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Equipment leaks: applicability... Categories: Generic Maximum Achievable Control Technology Standards § 63.1107 Equipment leaks:...

  18. 10 CFR 34.27 - Leak testing and replacement of sealed sources.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Nuclear Regulatory Commission's Regional Office listed in appendix D of 10 CFR part 20 of this chapter... 10 Energy 1 2013-01-01 2013-01-01 false Leak testing and replacement of sealed sources. 34.27... SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and...

  19. 10 CFR 34.27 - Leak testing and replacement of sealed sources.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Nuclear Regulatory Commission's Regional Office listed in appendix D of 10 CFR part 20 of this chapter... 10 Energy 1 2010-01-01 2010-01-01 false Leak testing and replacement of sealed sources. 34.27... SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.27 Leak testing and...

  20. Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing

    NASA Technical Reports Server (NTRS)

    Smith, L. Montgomery; Malone, Jo Anne; Crawford, Roger A.

    1995-01-01

    Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.

  1. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    NASA Technical Reports Server (NTRS)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

  2. Assessment of Field Experience Related to Pressurized Water Reactor Primary System Leaks

    SciTech Connect

    Shah, Vikram Naginbhai; Ware, Arthur Gates; Atwood, Corwin Lee; Sattison, Martin Blaine; Hartley, Robert Scott; Hsu, C.

    1999-08-01

    This paper presents our assessment of field experience related to pressurized water reactor (PWR) primary system leaks in terms of their number of rates, how aging affects frequency of leak events, the safety significance of such leaks, industry efforts to reduce leaks, and effectiveness of current leak detection systems. We have reviewed the licensee event reports to identify the events that took place during 1985 to the third quarter of 1996, and reviewed related technical literature and visited PWR plants to analyze these events. Our assessment shows that USNRC licensees have taken effective actions to reduce the number of leak events. One main reason for this decreasing trend was the elimination or reportable leakages from valve stem packing after 1991. Our review of leak events related to vibratory fatigue reveals a statistically significant decreasing trend with age (years of operation), but not in calendar time. Our assessment of worldwide data on leakage caused by thermal fatigue cracking is that the fatigue of aging piping is a safety significant issue. Our review of leak events has identified several susceptible sites in piping having high safety significance; but the inspection of some of these sites is not required by the ASME Code. These sites may be included in the risk-informed inspection programs.

  3. Assessment of Field Experience Related to Pressurized Water Reactor Primary System Leaks

    SciTech Connect

    A. G. Ware; C. Hsu; C. L. Atwood; M. B. Sattison; R. S. Hartley; V. N. Shah

    1999-02-01

    This paper presents our assessment of field experience related to pressurized water reactor (PWR) primary system leaks in terms of their number and rates, how aging affects frequency of leak events, the safety significance of such leaks, industry efforts to reduce leaks, and effectiveness of current leak detection systems. We have reviewed the licensee event reports to identify the events that took place during 1985 to the third quarter of 1996, and reviewed related technical literature and visited PWR plants to analyze these events. Our assessment shows that USNRC licensees have taken effective actions to reduce the number of leak events. One main reason for this decreasing trend was the elimination or reportable leakages from valve stem packing after 1991. Our review of leak events related to vibratory fatigue reveals a statistically significant decreasing trend with age (years of operation), but not in calendar time. Our assessment of worldwide data on leakage caused by thermal fatigue cracking is that the fatigue of aging piping is a safety significant issue. Our review of leak events has identified several susceptible sites in piping having high safety significance; but the inspection of some of these sites is not required by the ASME Code. These sites may be included in the risk-informed inspection programs.

  4. Fiber optic distributed chemical sensor for the real time detection of hydrocarbon fuel leaks

    NASA Astrophysics Data System (ADS)

    Mendoza, Edgar; Kempen, C.; Esterkin, Yan; Sun, Sunjian

    2015-09-01

    With the increase worldwide demand for hydrocarbon fuels and the vast development of new fuel production and delivery infrastructure installations around the world, there is a growing need for reliable hydrocarbon fuel leak detection technologies to provide safety and reduce environmental risks. Hydrocarbon leaks (gas or liquid) pose an extreme danger and need to be detected very quickly to avoid potential disasters. Gas leaks have the greatest potential for causing damage due to the explosion risk from the dispersion of gas clouds. This paper describes progress towards the development of a fast response, high sensitivity, distributed fiber optic fuel leak detection (HySense™) system based on the use of an optical fiber that uses a hydrocarbon sensitive fluorescent coating to detect the presence of fuel leaks present in close proximity along the length of the sensor fiber. The HySense™ system operates in two modes, leak detection and leak localization, and will trigger an alarm within seconds of exposure contact. The fast and accurate response of the sensor provides reliable fluid leak detection for pipelines, storage tanks, airports, pumps, and valves to detect and minimize any potential catastrophic damage.

  5. Potential role of infrared imaging for detecting facial seal leaks in filtering facepiece respirator users.

    PubMed

    Harber, Philip; Su, Jing; Badilla, Alejandro D; Rahimian, Rombod; Lansey, Kirsten R

    2015-01-01

    Infrared imaging (IRI) can detect airflow through and near respirator masks based upon temperature differences between ambient and exhaled air. This study investigated the potential usefulness of IRI for detecting leaks and providing insight into the sites and significance of leaks. Subjects (n = 165) used filtering facepiece N95 respirators (N95 FFR) in the course of a research study concerning training modalities. Short sequence video infrared images were obtained during use and with intentionally introduced facial seal leaks. Fit factor (FF) was measured with condensation nuclei count methods. IRI detected leaks were scored on a four-point scale and summarized as the Total Leak Score (TLS) over six coding regions and the presence or absence of a "Big Leak" (BL) in any location. A semi-automated interpretation algorithm was also developed. IRI detected leaks are particularly common in the nasal region, but these are of limited significance. IR imaging could effectively identify many large leaks. The TLS was related to FF. Although IRI scores were related to FF, the relationship is insufficiently close for IRI to substitute for quantitative fit-testing. Using FFRs infrared techniques have potential for identifying situations with very inadequate respiratory protection. PMID:25625873

  6. Intermediate-Scale Laboratory Experiments of Subsurface Flow and Transport Resulting from Tank Leaks

    SciTech Connect

    Oostrom, Martinus; Wietsma, Thomas W.

    2014-09-30

    Washington River Protection Solutions contracted with Pacific Northwest National Laboratory to conduct laboratory experiments and supporting numerical simulations to improve the understanding of water flow and contaminant transport in the subsurface between waste tanks and ancillary facilities at Waste Management Area C. The work scope included two separate sets of experiments: •Small flow cell experiments to investigate the occurrence of potential unstable fingering resulting from leaks and the limitations of the STOMP (Subsurface Transport Over Multiple Phases) simulator to predict flow patterns and solute transport behavior under these conditions. Unstable infiltration may, under certain conditions, create vertically elongated fingers potentially transporting contaminants rapidly through the unsaturated zone to groundwater. The types of leak that may create deeply penetrating fingers include slow release, long duration leaks in relatively permeable porous media. Such leaks may have occurred below waste tanks at the Hanford Site. •Large flow experiments to investigate the behavior of two types of tank leaks in a simple layered system mimicking the Waste Management Area C. The investigated leaks include a relatively large leak with a short duration from a tank and a long duration leak with a relatively small leakage rate from a cascade line.

  7. Optical leak detection of oxygen using IR-laser diodes

    NASA Technical Reports Server (NTRS)

    Disimile, P. J.; Fox, C.; Toy, N.

    1991-01-01

    The ability to accurately measure the concentration of gaseous oxygen and its corresponding flow rate is becoming of greater importance. The technique being presented is based on the principal of light attenuation due to the absorption of radiation by the A-band of oxygen which is located in the 759-770 nm wavelength range. With an ability to measure the change in the light transmission to 0.05 percent, a sensitive optical leak detection system which has a rapid time response is possible. In this research program, the application of laser diode technology and its ability to be temperature tuned to a selected oxygen absorption spectral peak has allowed oxygen concentrations as low as 16,000 ppm to be detected.

  8. Aortic Angiosarcoma: A Rare Cause for Leaking Thoracic Aneurysm

    SciTech Connect

    Hales, S. L. Locke, R.; Sandison, A.; Jenkins, M.; Hamady, M.

    2011-02-15

    Primary malignant tumours of the aorta are rare. They present with aneurysm formation, arterial occlusion, and embolic phenomenon. We report the case of a 56-year-old man whose initial presentation and investigations lead to emergency endovascular stenting of a descending thoracic aneurysm with a contained leak. Initial response was favourable, yet the patient presented again with worsening symptoms. The circum-aortic haematoma expanded by 50% on subsequent imaging, but no endoleak was identified. When altered bone marrow signal was identified on magnetic resonance imaging, the possibility of malignancy was considered. A metastatic skin lesion was then biopsied, which demonstrated morphological and immunohistochemical features consistent with metastases from a pleomorphic sarcoma of the aorta.

  9. Internal dissipation and heat leaks in quantum thermodynamic cycles

    NASA Astrophysics Data System (ADS)

    Correa, Luis A.; Palao, José P.; Alonso, Daniel

    2015-09-01

    The direction of the steady-state heat currents across a generic quantum system connected to multiple baths may be engineered to realize virtually any thermodynamic cycle. In spite of their versatility, such continuous energy-conversion systems are generally unable to operate at maximum efficiency due to non-negligible sources of irreversible entropy production. In this paper we introduce a minimal model of irreversible absorption chiller. We identify and characterize the different mechanisms responsible for its irreversibility, namely heat leaks and internal dissipation, and gauge their relative impact in the overall cooling performance. We also propose reservoir engineering techniques to minimize these detrimental effects. Finally, by looking into a known three-qubit embodiment of the absorption cooling cycle, we illustrate how our simple model may help to pinpoint the different sources of irreversibility naturally arising in more complex practical heat devices.

  10. Unique sled rig plugs oil leaking wells in surf zone

    SciTech Connect

    Zylstra, L.P. )

    1994-01-10

    Several leaking oil wells drilled in the late 1800s in the surf zone in Southern California required a specially built rig and platform for proper abandonment. The abandonment operations were complicated because the beach is heavily used by the public and the condition of the wells was unknown. A mobile sled was designed to support a drilling rig safely in the rough surf zone. The surf sled vehicle has a modular design for efficient assembly on the beach with minimal disturbance of the environment. No structures had to be built on the beach or in the surf zone to access the wellheads, thereby reducing costs and environmental impact. The surf sled vehicle used special equipment to keep the drilling rig level and to prevent oil spills or contamination during the drilling and abandonment procedures. The wells were abandoned safely and in a timely manner, despite the challenges of working in such a sensitive area. This paper describes the equipment and procedures used.

  11. Portable remote laser sensor for methane leak detection

    SciTech Connect

    Grant, W. B.; Hinkley Jr., E. D.

    1984-12-18

    A portable laser system for remote detection of methane gas leaks and concentrations is disclosed. The system transmitter includes first and second lasers, tuned respectively to a wavelength coincident with a strong absorption line of methane and a reference wavelength which is weakly absorbed by methane gas. The lasers are aimed at a topographical target along a system axis and the beams successively interrupted by a chopper wheel. The system receiver includes a spherical mirror for collecting the reflected laser radiation and focusing the collected radiation through a narrowband optical filter onto an optial detector. The filter is tuned to the wavelength of the two lasers, and rejects background noise to substantially improve the signal-to-noise ratio of the detector. The output of the optical detector is processed by a lock-in detector synchronized to the chopper, and which measures the difference between the first wavelength signal and the reference wavelength signal.

  12. Portable remote laser sensor for methane leak detection

    NASA Technical Reports Server (NTRS)

    Grant, W. B.; Hinkley, E. D., Jr. (Inventor)

    1984-01-01

    A portable laser system for remote detection of methane gas leaks and concentrations is disclosed. The system transmitter includes first and second lasers, tuned respectively to a wavelength coincident with a strong absorption line of methane and a reference wavelength which is weakly absorbed by methane gas. The system receiver includes a spherical mirror for collecting the reflected laser radiation and focusing the collected radiation through a narrowband optical filter onto an optial detector. The filter is tuned to the wavelength of the two lasers, and rejects background noise. The output of the optical detector is processed by a lock-in detector synchronized to the chopper, and which measures the difference between the first wavelength signal and the reference wavelength signal.

  13. Manage leak detection and repair programs cost-effectively

    SciTech Connect

    Stobbe, A.W. )

    1995-01-01

    Because of recently imposed lower fugitive-release limits for pumps and valves, refiners must use innovative, cost-effective ways to find, repair, monitoring, record and report process emissions. New regulations such as SOCMI HON (Synthetic Organic Chemical Manufacturing industry Hazardous Organic NESHAP) and Refinery MACT (Maximum Achievable Control Technology) set performance goals for hydrocarbon processing industry (HPI) facilities. To meet these performance standards, HPI facilities must set up stringent LDAR (Leak Detection and Repair) programs. Preparation methods define how to set up a database-management system to monitor/reduce fugitive emissions. The paper describes the database-management system, then discusses the determination of goals, collecting data, analyzing data, and management solutions to minimize costs.

  14. The effects of air leaks on solar air heating systems

    NASA Technical Reports Server (NTRS)

    Elkin, R.; Cash, M.

    1979-01-01

    This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

  15. The Use of Spontaneous Raman Scattering for Hydrogen Leak Detection

    NASA Technical Reports Server (NTRS)

    Degroot, Wim A.

    1994-01-01

    A fiber optic probe has been built and demonstrated that utilizes back scattered spontaneous Raman spectroscopy to detect and identify gaseous species. The small probe, coupled to the laser and data acquisition equipment with optical fibers, has applications in gaseous leak detection and process monitoring. The probe design and data acquisition system are described. Raman scattering theory has been reviewed and the results of intensity calculations of hydrogen and nitrogen Raman scattering are given. Because the device is in its developmental stage, only preliminary experimental results are presented here. Intensity scans across the rotational-vibrational Raman lines of nitrogen and hydrogen are presented. Nitrogen at a partial pressure of 0.077 MPa was detected. Hydrogen at a partial pressure of 2 kPa approached the lower limit of detectability with the present apparatus. Potential instrument improvements that would allow more sensitive and rapid hydrogen detection are identified.

  16. Infrared thermographic pipeline leak detection systems for pipeline rehabilitation programs

    NASA Astrophysics Data System (ADS)

    Weil, Gary J.

    1995-05-01

    Computerized infrared thermographic pipeline inspection is now a refined and accurate process having been thoroughly proven to be accurate, cost effective, and efficient technology for pipeline rehabilitation programs, during a 10 year development and testing process. The process has been used to test pipelines in chemical plants, water supply systems, steam lines, natural gas pipelines and sewer systems. Its non-contact, non-destructive ability to inspect large areas, from above ground, with 100% coverage and to locate subsurface leaks as well as the additional capability to locate voids and erosion surrounding pipelines, make its testing capabilities unique and highly desirable. This paper details the development of computerized infrared thermographic pipeline testing along with nine case histories illustrating its implementation problems and successes during various rehabilitation programs involving pipelines carrying water, gas, petroleum, and sewage.

  17. Infrared thermographic pipeline leak detection systems for pipeline rehabilitation programs

    NASA Astrophysics Data System (ADS)

    Weil, Gary J.

    1998-03-01

    Computerized infrared thermographic pipeline inspection is now a refined and accurate process having been thoroughly proven to be an accurate, cost effective, and efficient technology for pipeline rehabilitation programs, during a 10 year development and testing process. The process has been used to test pipelines in chemical plants, water supply systems, steam lines, natural gas pipelines and sewer systems. Its non- contact, non-destructive ability to inspect large areas, from above ground, with 100% coverage and to locate subsurface leaks as well as the additional capability to locate voids and erosion areas surrounding pipelines, make its testing capabilities unique and highly desirable. This paper details the development of computerized infrared thermographic pipeline testing along with case histories illustrating its implementation problems and successes during various rehabilitation programs involving pipelines carrying water, gas, petroleum, and sewage.

  18. Systemic capillary leak syndrome induced by influenza type A infection

    PubMed Central

    Kang, Kyeong Won; Heo, Sang Taek; Han, Sang Hoon; Park, Yong-Geun; Park, Hyun Soo

    2014-01-01

    A 42-year-old man visited the emergency department complaining of lower extremity swelling and myalgia. His influenza A antigen test was positive, and he was admitted for supportive care of severe myalgia. On the first hospital day, the swelling in his lower legs was aggravated with intolerable pain, and his creatine phosphokinase and hemoglobin levels were elevated. He was treated with massive hydration, albumin replacement, continuous venovenous hemofiltration, phlebotomy, and oseltamivir. The swelling and pain in his extremities were decreased without renal dysfunction, even though peripheral neuropathy and muscular complication persisted. Systemic capillary leak syndrome is a rare but life-threatening condition. The diagnosis is made clinically based on a classic triad of hypotension, hypoalbuminemia, and hemoconcentration. In our case, the influenza A infection was related to the capillary leakage.

  19. Fuel leak detection apparatus for gas cooled nuclear reactors

    DOEpatents

    Burnette, Richard D.

    1977-01-01

    Apparatus is disclosed for detecting nuclear fuel leaks within nuclear power system reactors, such as high temperature gas cooled reactors. The apparatus includes a probe assembly that is inserted into the high temperature reactor coolant gaseous stream. The probe has an aperture adapted to communicate gaseous fluid between its inside and outside surfaces and also contains an inner tube for sampling gaseous fluid present near the aperture. A high pressure supply of noncontaminated gas is provided to selectively balance the pressure of the stream being sampled to prevent gas from entering the probe through the aperture. The apparatus includes valves that are operable to cause various directional flows and pressures, which valves are located outside of the reactor walls to permit maintenance work and the like to be performed without shutting down the reactor.

  20. Evaluation method of leachate leaking from carcass burial site

    NASA Astrophysics Data System (ADS)

    Park, S.; Kim, H.; Lee, M.; Lee, K.; Kim, S.; Kim, M.; Kim, H.; Kim, T.; Han, J.

    2012-12-01

    More than 150,000 cattle carcasses and 3,140,000 pig carcasses were buried all over the nation in Korea because of 2010 outbreak of foot and mouth disease (FMD). Various disposal Techniques such as incineration, composting, rendering, and burial have been developed and applied to effectively dispose an animal carcass. Since a large number of carcasses should be disposed for a short-term period to prevent the spread of FMD virus, most of the carcasses were disposed by mass burial technique. However, a long-term management and monitoring of leachate discharges are required because mass burial can cause soil and groundwater contamination. In this study, we used key parameters related to major components of leachate such as NH4-N, NO3-N, Cl-, E.coli and electrical conductivity as potential leachate contamination indicator to determine leachate leakage from the site. We monitored 300 monitoring wells in both burial site and the monitoring well 5m away from burial sites to identify leachate leaking from burial site. Average concentration of NH3-N in 300 monitoring wells, both burial site and the well 5m away from burial sites, were 2,593 mg/L and 733 mg/L, respectively. 24% out of 300 monitoring wells showed higher than 10 mg/L NH4-N, 100 mg/L Cl- and than 800 μS/cm electrical conductivity. From this study, we set up 4 steps guidelines to evaluate leachate leakage like; step 1 : High potential step of leachate leakage, step 2 : Middle potential step of leachate leakage, step 3 : Low potential step of leachate leakage, step 4 : No leachate leakage. On the basis of this result, we moved 34 leachate leaking burial sites to other places safely and it is necessary to monitor continuously the monitoring wells for environmental protection and human health.

  1. Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal

    NASA Technical Reports Server (NTRS)

    Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.

    2011-01-01

    Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the

  2. Severe hypo-osmotic hyponatraemia due to chylous leak following radical neck dissection.

    PubMed

    Andreou, Zenon; Trinidade, Aaron; Shakeel, Muhammad; Argiris, Konstantin; Panesar, Jaan; Kothari, Prasad

    2013-03-01

    Chylous leak is a documented complication of radical neck dissection with well recognised morbidities, including wound breakdown, hypovolaemia and hypoalbuminaemia. Other less well-documented electrolyte imbalances can also ensue. We aim to raise awareness about hypo-osmotic hyponatraemia as a potentially fatal, commonly overlooked complication of high-output chylous leaks. Following identification of his hyponatraemia, this patient underwent successful management in the intensive therapy unit, followed by surgical repair of his chylous leak. Hypo-osmotic hyponatraemia as a complication of chylous leak is not well documented, is likely to be overlooked when present, and is potentially life-threatening. It should be sought after in any patient with a high-output chylous leak following neck dissection.

  3. Evaluation and refinement of leak-rate estimation models. Revision 1

    SciTech Connect

    Paul, D.D.; Ahmad, J.; Scott, P.M.; Flanigan, L.F.; Wilkowski, G.M.

    1994-06-01

    Leak-rate estimation models are important elements in developing a leak-beforebreak methodology in piping integrity and safety analyses. Existing thermalhydraulic and crack-opening-area models used in current leak-rate estimations have been incorporated into a single computer code for leak-rate estimation. The code is called SQUIRT, which stands for Seepage Quantification of Upsets In Reactor Tubes. The SQUIRT program has been validated by comparing its thermalhydraulic predictions with the limited experimental data that have been published on two-phase flow through slits and cracks, and by comparing its crack-opening-area predictions with data from the Degraded Piping Program. In addition, leak-rate experiments were conducted to obtain validation data for a circumferential fatigue crack in a carbon steel pipe girth weld.

  4. Detecting well casing leaks in Bangladesh using a salt spiking method

    USGS Publications Warehouse

    Stahl, M.O.; Ong, J.B.; Harvey, C.F.; Johnson, C.D.; Badruzzaman, A.B.M.; Tarek, M.H.; VanGeen, A.; Anderson, J.A.; Lane, J.W.

    2014-01-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries.

  5. Conservative Management of an Intraoperative Chyle Leak: A Case Report and Literature Review.

    PubMed

    Meyer, Charles D; McLeod, Ian K; Gallagher, Daniel J

    2016-09-01

    Chyle leaks are a rare but potentially fatal complication of head and neck surgery carrying an incidence as high as 8.3%. The development of a chyle leak carries significant morbidity ranging from delayed wound healing to oropharyngeal fistulas. Presented here is a case of a chyle leak that developed following a left posterolateral neck dissection that was successfully managed with a combination of drain suction, pressure dressing, and a fat-restricted diet. However, the patient's course was complicated by repeated chyle leak recurrences that may have been associated with the initiation of medium-chain triglyceride supplementation. Although further research is required to establish a causal relationship, these findings support the concerns of other investigators about the possible counterproductive role of medium-chain triglyceride supplementation in the management of chyle leaks. PMID:27612380

  6. Detecting Well Casing Leaks in Bangladesh Using a Salt Spiking Method

    PubMed Central

    Stahl, M.O.; Ong, J.B.; Harvey, C.F.; Johnson, C.D.; Badruzzaman, A.B.M.; Tarek, M.H.; van Geen, A.; Anderson, J.A.; Lane, J.W.

    2014-01-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries. PMID:24898169

  7. The Relief of Unilateral Painful Thoracic Radiculopathy without Headache from Remote Spontaneous Spinal Cerebrospinal Fluid Leak

    PubMed Central

    Son, Byung-chul; Ha, Sang-woo; Lee, Si-hoon; Choi, Jin-gyu

    2016-01-01

    Spontaneous intracranial hypotension (SIH) caused by spontaneous spinal cerebrospinal fluid (CSF) leaks produces orthostatic headaches. Although upper arm pain or paresthesia is reportedly associated with SIH from spontaneous spinal CSF leak in the presence of orthostatic headache, low thoracic radicular pain due to spontaneous spinal CSF leak unassociated with postural headache is extremely rare. We report a 67-year-old female who presented with chronic, positional radicular right T11 pain. Computed tomography myelography showed a spontaneous lumbar spinal CSF leak at L2-3 and repeated lumbar epidural blood patches significantly alleviated chronic, positional, and lower thoracic radiculopathic pain. The authors speculate that a chronic spontaneous spinal CSF leak not severe enough to cause typical orthostatic headache or epidural CSF collection may cause local symptoms such as irritation of a remote nerve root. There might be considerable variabilities in the clinical features of SIH which can present a diagnostic challenge. PMID:27445613

  8. Sieving characteristics of cytokine- and peroxide-induced epithelial barrier leak: Inhibition by berberine

    PubMed Central

    DiGuilio, Katherine M; Mercogliano, Christina M; Born, Jillian; Ferraro, Brendan; To, Julie; Mixson, Brittany; Smith, Allison; Valenzano, Mary Carmen; Mullin, James M

    2016-01-01

    AIM: To study whether the inflammatory bowel disease (IBD) colon which exhibits varying severity and cytokine levels across its mucosa create varying types of transepithelial leak. METHODS: We examined the effects of tumor necrosis factor-α (TNF-α), interferon-γ (IFN-γ), interleukin-1-β (IL1β) and hydrogen peroxide (H2O2) - singly and in combinations - on barrier function of CACO-2 cell layers. Our focus was on the type (not simply the magnitude) of transepithelial leak generated by these agents as measured by transepithelial electrical resistance (TER) and transepithelial flux of 14C-D-mannitol, 3H-Lactulose and 14C-Polyethylene glycol as radiolabeled probe molecules. The isoquinoline alkaloid, berberine, was then examined for its ability to reduce specific types of transepithelial leak. RESULTS: Exposure to TNF-α alone (200 ng/mL; 48 h) induced a 50% decrease in TER, i.e., increased leak of Na+ and Cl- - with only a marginal but statistically significant increase in transepithelial leak of 14C-mannitol (Jm). Exposure to TNF-α + IFN-γ (200 ng/mL; 48 h) + IL1β (50 ng/mL; 48 h) did not increase the TER change (from TNF-α alone), but there was now a 100% increase in Jm. There however was no increase in transepithelial leak of two larger probe molecules, 3H-lactulose and 14C-polyethylene glycol (PEG). However, exposure to TNF-α + IFN-γ + IL1β followed by a 5 h exposure to 2 mmol/L H2O2 resulted in a 500% increase in 14C-PEG leak as well as leak to the luminal mitogen, epidermal growth factor. CONCLUSION: This model of graded transepithelial leak is useful in evaluating therapeutic agents reducing IBD morbidity by reducing barrier leak to various luminal substances. PMID:27190695

  9. Influence of Preoperative Radiation Field on Postoperative Leak Rates in Esophageal Cancer Patients after Trimodality Therapy

    PubMed Central

    Juloori, Aditya; Tucker, Susan L.; Komaki, Ritsuko; Liao, Zhongxing; Correa, Arlene M.; Swisher, Stephen G.; Hofstetter, Wayne L.; Lin, Steven H.

    2014-01-01

    Introduction Postoperative morbidities, such as anastomotic leaks, are common after trimodality therapy (chemoradiation followed by surgery) for esophageal cancer. We investigated for factors associated with an increased incidence of anastomotic leaks. Methods Data from 285 esophageal cancer patients treated from 2000–2011 with trimodality therapy was analyzed. Anastomotic location relative to preoperative radiation field was assessed using postoperative computed tomographic imaging. Logistic regression was used to evaluate for factors associated with any or clinically relevant (CR) (≥ grade 2) leaks. Results Overall anastomotic leak rate was 11% (31/285), and CR leak rate was 6% (17/285). Multivariable analysis identified body mass index (BMI) (OR 1.09, 95%CI 1.00–1.17; OR 1.11, 95%CI 1.01–1.22), three-field surgery (OR 10.01, 95%CI 3.83–26.21; OR 4.83, 95%CI 1.39–16.71), and within radiation field (“in-field”) anastomosis (OR 5.37, 95%CI 2.21–13.04; OR 8.63, 95%CI 2.90–25.65) as independent predictors of both all grade and CR leaks, respectively. While patients with distal esophageal tumors and Ivor-Lewis surgery had the lowest incidence of all grade (6.5%) and CR leaks (4.2%), most of the leaks were associated with the anastomosis constructed within the field of radiation (in-field: 39% and 30% versus out-of-field: 2.6% and 1.0%, respectively, for total and CR leaks, p<0.0001, Fisher’s Exact test). Conclusions Esophagogastric anastomosis placed within the preoperative radiation field was a very strong predictor for anastomotic leaks in esophageal cancer patients treated with trimodality therapy, among other factors. Surgical planning should include a critical evaluation of the preoperative radiation fields to ensure proper anastomotic placement after chemoradiation therapy. PMID:24736077

  10. The International Space Station 2B Photovoltaic Thermal Control System (PVTCS) Leak: An Operational History

    NASA Technical Reports Server (NTRS)

    Vareha, Anthony N.

    2014-01-01

    As early as 2004, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B electrical power channel began slowly leaking ammonia overboard. Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity (EVA) during the STS-134 Space Shuttle mission. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. In mid-2012, the leak rate increased from 1.5lbm/year to approximately 5lbm/year. As a result, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to an adjacent dormant thermal control system. This EVA, US EVA 20, was successfully executed on November 1, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a different radiator than what the system was designed to utilize. Data monitoring over the next several months showed that the isolated radiator had not been leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, US EVA 21 was in progress to replace the coolant pump - the only remaining replaceable leak source. This was successful, and telemetry monitoring has shown that indeed the coolant pump was the leak source and was thus isolated from the running 2B PVTCS. This paper will explore the management of the 2B PVTCS leak from the operations perspective.

  11. Detection and location of leaks in district heating steam systems: Survey and review of current technology and practices

    SciTech Connect

    Kupperman, D.S.; Raptis, A.C.; Lanham, R.N.

    1992-03-01

    This report presents the results of a survey undertaken to identify and characterize current practices for detecting and locating leaks in district heating systems, particular steam systems. Currently used technology and practices are reviewed. In addition, the survey was used to gather information that may be important for the application of acoustic leak detection. A few examples of attempts to locate leaks in steam and hot water pipes by correlation of acoustic signals generated by the leaks are also discussed.

  12. 40 CFR 63.7922 - How do I demonstrate continuous compliance with the work practice standards for equipment leaks?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... compliance with the work practice standards for equipment leaks? 63.7922 Section 63.7922 Protection of... Hazardous Air Pollutants: Site Remediation Equipment Leaks § 63.7922 How do I demonstrate continuous compliance with the work practice standards for equipment leaks? (a) You must demonstrate...

  13. 40 CFR 63.7887 - What are the general standards I must meet for my affected equipment leak sources?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... another subpart in 40 CFR part 61 or 40 CFR part 63, you may control emissions of the HAP listed in Table... meet for my affected equipment leak sources? 63.7887 Section 63.7887 Protection of Environment... affected equipment leak sources? (a) You must control HAP emissions from equipment leaks from...

  14. 40 CFR 63.7922 - How do I demonstrate continuous compliance with the work practice standards for equipment leaks?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... compliance with the work practice standards for equipment leaks? 63.7922 Section 63.7922 Protection of... Hazardous Air Pollutants: Site Remediation Equipment Leaks § 63.7922 How do I demonstrate continuous compliance with the work practice standards for equipment leaks? (a) You must demonstrate...

  15. 40 CFR 61.243-2 - Alternative standards for valves in VHAP service-skip period leak detection and repair.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... VHAP service-skip period leak detection and repair. 61.243-2 Section 61.243-2 Protection of Environment... AIR POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) § 61.243-2 Alternative standards for valves in VHAP service—skip period leak detection and repair. (a)(1) An owner...

  16. 40 CFR 63.7922 - How do I demonstrate continuous compliance with the work practice standards for equipment leaks?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance with the work practice standards for equipment leaks? 63.7922 Section 63.7922 Protection of... Hazardous Air Pollutants: Site Remediation Equipment Leaks § 63.7922 How do I demonstrate continuous compliance with the work practice standards for equipment leaks? (a) You must demonstrate...

  17. 40 CFR 63.1296 - Standards for slabstock flexible polyurethane foam production-HAP ABA equipment leaks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... polyurethane foam production-HAP ABA equipment leaks. 63.1296 Section 63.1296 Protection of Environment... foam production—HAP ABA equipment leaks. Each owner or operator of a new or existing slabstock affected... control HAP ABA emissions from leaks from transfer pumps, valves, connectors, pressure-relief valves,...

  18. 40 CFR 61.243-2 - Alternative standards for valves in VHAP service-skip period leak detection and repair.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... VHAP service-skip period leak detection and repair. 61.243-2 Section 61.243-2 Protection of Environment... AIR POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) § 61.243-2 Alternative standards for valves in VHAP service—skip period leak detection and repair. (a)(1) An owner...

  19. 40 CFR 63.1296 - Standards for slabstock flexible polyurethane foam production-HAP ABA equipment leaks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... polyurethane foam production-HAP ABA equipment leaks. 63.1296 Section 63.1296 Protection of Environment... production—HAP ABA equipment leaks. Each owner or operator of a new or existing slabstock affected source... emissions from leaks from transfer pumps, valves, connectors, pressure-relief valves, and open-ended...

  20. 40 CFR 63.7887 - What are the general standards I must meet for my affected equipment leak sources?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... another subpart in 40 CFR part 61 or 40 CFR part 63, you may control emissions of the HAP listed in Table... meet for my affected equipment leak sources? 63.7887 Section 63.7887 Protection of Environment... affected equipment leak sources? (a) You must control HAP emissions from equipment leaks from...