Sample records for led backlight unit

  1. A superior architecture of brightness enhancement for display backlighting

    NASA Astrophysics Data System (ADS)

    Dross, Oliver; Parkyn, William A.; Chaves, Julio; Falicoff, Waqidi; Miñano, Juan Carlos; Benitez, Pablo; Alvarez, Roberto

    2006-08-01

    Brightness enhancement of backlighting for displays is typically achieved via crossed micro prismatic films that are introduced between a backlight unit and a transmissive (LCD) display. Prismatic films let pass light only into a restricted angular range, while, in conjunction with other reflective elements below the backlight, all other light is recycled within the backlight unit, thereby increasing the backlight luminance. This design offers no free parameters to influence the resulting light distribution and suffers from insufficient stray light control. A novel strategy of light recycling is introduced, using a microlens array in conjunction with a hole array in a reflective surface, that can provide higher luminance, superior stray light control, and can be designed to meet almost any desired emission pattern. Similar strategies can be applied to mix light from different colored LEDs being mounted upside down to shine into a backlight unit.

  2. [Analysis of color gamut of LCD system based on LED backlight with area-controlling technique].

    PubMed

    Li, Fu-Wen; Jin, Wei-Qi; Shao, Xi-Bin; Zhang, Li-Lei; Wan, Li-Fang

    2010-05-01

    Color gamut as a significant performance index for display system describes the color reproduction ability IN real scenes. Liquid crystal display (LCD) is the most popular technology in flat panel display. However, conventional cold cathode fluorescent lamp (CCFL) backlight of LCD can not behave high color gamut compared with cathode ray tube (CRT). The common used method of color gamut measuring for LCD system is introduced at the beginning. According to the inner structure and display principle of LCD system, there are three major factors deciding LCD's color gamut: spectral properties of backlight, transmittance properties of color filters and performance of liquid crystal panel. Instead of conventional backlight CCFL, RGB-LED backlight is used for improving color reproduction of LCD display system. Due to the imperfect match between RGB-LED' s spectra and color filter's transmittance, the color filter would reduce the color gamut of LCD system more or less. Therefore, LCD system based on LED backlight with area-control technique is introduced which modifies backlight control signal according to the input signal After analyzing and calculating the spectra of LED backlight which passes through the color filters using method of colorimetry, the area sizes of color gamut triangles of RGB-LED backlight with area-control and RGB-LED backlight without area-control LCD systems are compared and the relationship between color gamut and varying contrast of liquid crystal panel is analyzed. It is indicated that LED backlight with area-control technique can avoid color saturation dropping and have little effects on the contrast variation of liquid crystal panel. In other words, LED backlight with area-control technique relaxes the requirements of both color filter performance and liquid crystal panel. Thus, it is of importance to improve the color gamut of the current LCD system with area-control LED backlight.

  3. Technology of Wide Color Gamut Backlight with Light-Emitting Diode for Liquid Crystal Display Television

    NASA Astrophysics Data System (ADS)

    Kakinuma, Koichiro

    2006-05-01

    The development of light-emitting diode (LED) backlight a wide-color-gamut and mercury-free has become active in liquid crystal display (LCD) industry. Reports on the development of backlights, such as a direct illumination-type back-light and a guided light illumination-type LED backlight were published. The fabrication of an actual commercial product has been progressing under this active development. Sony Corporation launched an LED-backlit LCD television (TV) model, dubbed QUALIA 005, the world’s first home-use television featuring LED backlighting. This product offers a very wide color reproduction range, delivering a color gamut of 150% of that typically achieved by conventional televisions. In this paper, the background of the development of the LED backlight system “TriluminosTM” and the technologies used to realize the wide color gamut are discussed. The main issues to be solved for the commercialization were how to reduce the brightness/color non uniformity of the backlight and how to treat heat generation from the LED. The standardization of wide color space definition xvYCC and LED backlight LCD television combination is expected to result in a more vivid and correct color expression, and a forecast that extends to the market in the future.

  4. Improved LED backlight with unique color and intensity control and NVIS capability

    NASA Astrophysics Data System (ADS)

    Herman, Robert; Zagar, Pete; Ulijasz, Ted; Hansen, Hans C.; Ellner, Fred

    2006-05-01

    Currently deployed conventional flat panel AMLCD displays employ fluorescent lamp backlights to achieve the required lighting levels for cockpits in high performance aircraft. Advances have been made in backlighting technology by replacing fluorescent lamps with high performance LEDs. However, these new LED-based backlights are lacking in control of color and luminance intensity especially when related to NVIS requirements in a cockpit. This paper describes a unique integration of LED, electronic, and optical components to meet the requirements of high performance aircraft over their extreme range of operating environments. The LED-based backlight utilizes state-of-art components to enable daylight, night, and NVIS requirements to be implemented in a simple cost-effective package. The performance results presented highlight the advantages of this new design when compared to currently available backlighting designs. Techniques as described in section 2 of this paper are covered under patent application to the US and International Patent Offices.

  5. Simple liquid crystal display backlight unit comprising only a single-sheet micropatterned polydimethylsiloxane (PDMS) light-guide plate.

    PubMed

    Lee, Joo-Hyung; Lee, Hong-Seok; Lee, Byung-Kee; Choi, Won-Seok; Choi, Hwan-Young; Yoon, Jun-Bo

    2007-09-15

    A simple liquid crystal display (LCD) backlight unit (BLU) comprising only a single-sheet polydimethylsiloxane (PDMS) light-guide plate (LGP) has been developed. The PDMS LGP, having micropatterns with an inverse-trapezoidal cross section, was fabricated by backside 3-D diffuser lithography followed by PDMS-to-PDMS replication. The fabricated BLU showed an average luminance of 2878 cd/m(2) with 73.3% uniformity when mounted in a 5.08 cm backlight module with four side view 0.85cd LEDs. The developed BLU can greatly reduce the cost and thickness of LCDs, and it can be applied to flexible displays as a flexible light source due to the flexible characteristic of the PDMS itself.

  6. Colour gamut enhancement with remote light conversion mechanism

    NASA Astrophysics Data System (ADS)

    Koseoglu, D.; Sezer, Y. S.; Karsli, K.

    2018-01-01

    The backlight unit spectrum of liquid crystal displays (LCD) directly affects the colour gamut. With the invention of GaN based blue light emitting diodes (LED), phosphors and quantum dots (QD) have gained considerable scientific interest due to their broad range of applications especially in lighting and display technologies. These phosphors and QDs are used to convert the blue light of the LEDs into white in general lighting. On the other hand, in display systems, they are used to generate red and green bands. There are different application methods such as on-chip and remote configurations. In this study, we concentrate on remote phosphor and QD backlight configurations where the light conversion is done away from the chips. In our display designs, we used GaN based blue LED lateral chips as an excitation source, on the other hand, light conversion layers were placed in backlight units as a thin film for the emission of green and red bands. The mixing ratios of these composite layers were arranged to match the emission spectrum of the blue LEDs and the light conversion layer to the colour filters of the LCD, so that the green, blue, and red bands efficiently widens the colour space. The results were also compared with the on-chip phosphor arrangements.

  7. Power management of direct-view LED backlight for liquid crystal display

    NASA Astrophysics Data System (ADS)

    Lee, Xuan-Hao; Lin, Che-Chu; Chang, Yu-Yu; Chen, He-Xiang; Sun, Ching-Cherng

    2013-03-01

    In this paper, we present a study of management of power in function of luminous efficacy of white LED as well as the efficiency enhancement of the direct-view backlight with photon recycling. A cavity efficiency as high as 90.7% is demonstrated for a direct-view backlight with photon recycling. In the future, with a 90% backlight cavity, luminous efficacy of 200 lm/W for white LEDs, and a transmission efficiency of 10% for the liquid crystal panel, the required power of LEDs could be only 16 W. Up to 85% energy saving could be achieved in comparison to the power of the current liquid crystal display.

  8. Color dependence with horizontal-viewing angle and colorimetric characterization of two displays using different backlighting

    NASA Astrophysics Data System (ADS)

    Castro, José J.; Pozo, Antonio M.; Rubiño, Manuel

    2013-11-01

    In this work we studied the color dependence with a horizontal-viewing angle and colorimetric characterization of two liquid-crystal displays (LCD) using two different backlighting: Cold Cathode Fluorescent Lamps (CCFLs) and light-emitting diodes (LEDs). The LCDs studied had identical resolution, size, and technology (TFT - thin film transistor). The colorimetric measurements were made with the spectroradiometer SpectraScan PR-650 following the procedure recommended in the European guideline EN 61747-6. For each display, we measured at the centre of the screen the chromaticity coordinates at horizontal viewing angles of 0, 20, 40, 60 and 80 degrees for the achromatic (A), red (R), green (G) and blue (B) channels. Results showed a greater color-gamut area for the display with LED backlight, compared with the CCFL backlight, showing a greater range of colors perceptible by human vision. This color-gamut area diminished with viewing angle for both displays. Higher differences between trends for viewing angles were observed in the LED-backlight, especially for the R- and G-channels, demonstrating a higher variability of the chromaticity coordinates with viewing angle. The best additivity was reached by the LED-backlight display (a lower error percentage). LED-backlight display provided better color performance of visualization.

  9. LED-driven backlights for automotive displays

    NASA Astrophysics Data System (ADS)

    Strauch, Frank

    2007-09-01

    As a light source the LED has some advantage over the traditionally used fluorescence tube such as longer life or lower space consumption. Consequently customers are asking for the LED lighting design in their products. We introduced in a company owned backlight the white LED technology. This step opens the possibility to have access to the components in the display market. Instead of having a finalized display product which needs to be integrated in the head unit of a car we assemble the backlight, the glass, own electronics and the housing. A major advantage of this concept is the better control of the heat flow generated by the LEDs to the outer side because only a common housing is used for all the components. Also the requirement for slim products can be fulfilled. As always a new technology doesn't come with advantages only. An LED represents a point source compared to the well-known tube thus requiring a mixing zone for the multiple point sources when they enter a light guide. This zone can't be used in displays because of the lack of homogeneity. It's a design goal to minimize this zone which can be helped by the right choice of the LED in terms of slimness. A step ahead is the implementation of RGB LEDs because of their higher color rendering abilities. This allows for the control of the chromaticity point under temperature change but as a drawback needs a larger mixing zone.

  10. Visual ergonomic evaluations on four different designs of LED traffic signs

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Huang, Ting-Yuan; Lee, Tsung-Xian; Sun, Ching-Cherng

    2017-08-01

    To investigate the legibility and visual comfort of LED traffic signs, an ergonomic experiment is performed on four custom-designed LED traffic signs, including three self-luminous ones as LED lightbox, LED backlight and regional LED backlight, and one non-self-luminous sign with external LED lighting. The four signs are hanged side-by-side and evaluated by observers through questionnaires. The signage dimension is one-sixth of the real freeway traffic signs, and the observation distance is 25 m. The luminance of three self-luminous signs is 216 cd/m2. The illuminance of external LED lighting is 400 lux on the traffic sign. The ambient illuminance is 2.8 and 6.0 lux in two rounds. The results show that self-luminous traffic signs provide superior legibility, visual comfort and user preference than the non-self-luminous one. Among the three self-luminous signs, regional LED backlight is most susceptible to the ambient illumination. LED lightbox has significantly better preference score than LED backlight under darker ambient lighting. Only LED lightbox has significantly better visual comfort than external LED lighting in the brighter environment. Based on the four LED traffic signs evaluated in this study, we suggest LED lightbox as the prior choice. Further investigations on the effect of ambient illumination and other designs of self-luminous traffic signs are in progress.

  11. Stereoscopic display technologies for FHD 3D LCD TV

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Sik; Ko, Young-Ji; Park, Sang-Moo; Jung, Jong-Hoon; Shestak, Sergey

    2010-04-01

    Stereoscopic display technologies have been developed as one of advanced displays, and many TV industrials have been trying commercialization of 3D TV. We have been developing 3D TV based on LCD with LED BLU (backlight unit) since Samsung launched the world's first 3D TV based on PDP. However, the data scanning of panel and LC's response characteristics of LCD TV cause interference among frames (that is crosstalk), and this makes 3D video quality worse. We propose the method to reduce crosstalk by LCD driving and backlight control of FHD 3D LCD TV.

  12. New reversing freeform lens design method for LED uniform illumination with extended source and near field

    NASA Astrophysics Data System (ADS)

    Zhao, Zhili; Zhang, Honghai; Zheng, Huai; Liu, Sheng

    2018-03-01

    In light-emitting diode (LED) array illumination (e.g. LED backlighting), obtainment of high uniformity in the harsh condition of the large distance height ratio (DHR), extended source and near field is a key as well as challenging issue. In this study, we present a new reversing freeform lens design algorithm based on the illuminance distribution function (IDF) instead of the traditional light intensity distribution, which allows uniform LED illumination in the above mentioned harsh conditions. IDF of freeform lens can be obtained by the proposed mathematical method, considering the effects of large DHR, extended source and near field target at the same time. In order to prove the claims, a slim direct-lit LED backlighting with DHR equal to 4 is designed. In comparison with the traditional lenses, illuminance uniformity of LED backlighting with the new lens increases significantly from 0.45 to 0.84, and CV(RMSE) decreases dramatically from 0.24 to 0.03 in the harsh condition. Meanwhile, luminance uniformity of LED backlighting with the new lens is obtained as high as 0.92 at the condition of extended source and near field. This new method provides a practical and effective way to solve the problem of large DHR, extended source and near field for LED array illumination.

  13. High collimated coherent illumination for reconstruction of digitally calculated holograms: design and experimental realization

    NASA Astrophysics Data System (ADS)

    Morozov, Alexander; Dubinin, German; Dubynin, Sergey; Yanusik, Igor; Kim, Sun Il; Choi, Chil-Sung; Song, Hoon; Lee, Hong-Seok; Putilin, Andrey; Kopenkin, Sergey; Borodin, Yuriy

    2017-06-01

    Future commercialization of glasses-free holographic real 3D displays requires not only appropriate image quality but also slim design of backlight unit and whole display device to match market needs. While a lot of research aimed to solve computational issues of forming Computer Generated Holograms for 3D Holographic displays, less focus on development of backlight units suitable for 3D holographic display applications with form-factor of conventional 2D display systems. Thereby, we report coherent backlight unit for 3D holographic display with thickness comparable to commercially available 2D displays (cell phones, tablets, laptops, etc.). Coherent backlight unit forms uniform, high-collimated and effective illumination of spatial light modulator. Realization of such backlight unit is possible due to holographic optical elements, based on volume gratings, constructing coherent collimated beam to illuminate display plane. Design, recording and measurement of 5.5 inch coherent backlight unit based on two holographic optical elements are presented in this paper.

  14. RGB LED with smart control in the backlight and lighting

    NASA Astrophysics Data System (ADS)

    Ku, Johnson C. S.; Lee, C. J.

    2008-02-01

    To improve the LED (Light Emitting Diode) efficacy is the major consideration when the backlight and lighting system are implemented. An important source of poor efficacy come from the chip process or heat dissipation. White LED used blue chip with phosphor is the current solution and inadequate for the tunable color temperature system. The use of RGB (Red, Green and Blue) LED with smart control is presented in this study. The resulting coupled optical and thermal shows the better performance when it is synthesized in conjunction with a degree of color mixing technology.

  15. Automated platform for determination of LEDs spatial radiation pattern

    NASA Astrophysics Data System (ADS)

    Vladescu, Marian; Vuza, Dan Tudor

    2015-02-01

    Nowadays technologies lead to remarkable properties of the light-emitting diodes (LEDs), making them attractive for more and more applications, such as: interior and exterior lighting, outdoor LED panels, traffic signals, automotive (tail and brake lights, backlighting in dashboard and switches), backlighting of display panels, LCD displays, symbols on switches, keyboards, graphic boards and measuring scales. Usually, LEDs are small light sources consisting of a chip placed into a package, which may bring additional optics to this encapsulated ensemble, resulting in a less or more complex spatial distribution of the light intensity, with particular radiation patterns. This paper presents an automated platform designed to allow a quick and accurate determination of the spatial radiation patterns of LEDs encapsulated in various packages. Keywords: LED, luminous

  16. Binning and filtering: the six-color solution

    NASA Astrophysics Data System (ADS)

    Ashdown, Ian; Robinson, Shane; Salsbury, Marc

    2006-08-01

    The use of LED backlighting for LCD displays requires careful binning of red, green, and blue LEDs by dominant wavelength to maintain the color gamuts as specified by NTSC, SMPTE, and EBU/ITU standards. This problem also occurs to a lesser extent with RGB and RGBA assemblies for solid-state lighting, where color gamut consistency is required for color-changing luminaires. In this paper, we propose a "six-color solution," based on Grassman's laws, that does not require color binning, but nevertheless guarantees a fixed color gamut that subsumes the color gamuts of carefully-binned RGB assemblies. A further advantage of this solution is that it solves the problem of peak wavelength shifts with varying junction temperatures. The color gamut can thus remain fixed over the full range of LED intensities and ambient temperatures. A related problem occurs with integrated circuit (IC) colorimeters used for optical feedback with LED backlighting and RGB(A) solid-state lighting, wherein it can be difficult to distinguish between peak wavelength shifts and changes in LED intensity. We apply our six-color solution to the design of a novel colorimeter for LEDs that independently measures changes in peak wavelength and intensity. The design is compatible with current manufacturing techniques for tristimulus colorimeter ICs. Together, the six-color solution for LEDs and colorimeters enables less expensive LED backlighting and solid-state lighting systems with improved color stability.

  17. Image-classification-based global dimming algorithm for LED backlights in LCDs

    NASA Astrophysics Data System (ADS)

    Qibin, Feng; Huijie, He; Dong, Han; Lei, Zhang; Guoqiang, Lv

    2015-07-01

    Backlight dimming can help LCDs reduce power consumption and improve CR. With fixed parameters, dimming algorithm cannot achieve satisfied effects for all kinds of images. The paper introduces an image-classification-based global dimming algorithm. The proposed classification method especially for backlight dimming is based on luminance and CR of input images. The parameters for backlight dimming level and pixel compensation are adaptive with image classifications. The simulation results show that the classification based dimming algorithm presents 86.13% power reduction improvement compared with dimming without classification, with almost same display quality. The prototype is developed. There are no perceived distortions when playing videos. The practical average power reduction of the prototype TV is 18.72%, compared with common TV without dimming.

  18. Wide color gamut display with white and emerald backlighting.

    PubMed

    Duan, Lvyin; Lei, Zhichun

    2018-02-20

    This paper proposes a wide color gamut approach that uses white and emerald lighting units as the backlight of the liquid crystal display. The white and emerald backlights are controlled by the image to be displayed. The mixing ratio of the white and the emerald lighting is analyzed so that the maximal color gamut coverage ratio can be achieved. Experimental results prove the effectiveness of the wide color gamut approach using white and emerald backlights.

  19. LED backlight system with fiber-optic red, green, blue to white color combiner

    NASA Astrophysics Data System (ADS)

    Kim, Hye R.; Jeong, Yunsong; Lee, Jhang-Woo; Oh, Kyunghwan

    2006-09-01

    As an application in the backlight system of small LCD display, we realized a pure white light source by mixing red, green, blue (RGB) lights using a 3 X 3 Hard Plastic Cladding Fiber (HPCF) coupler. We also proposed the 0.44 inch LED backlight system with these fiber-optic pure white sources and characterized its illumination characteristics. Using optimized fusion-tapering technique, we fabricated HPCF coupler which combines three input lights over the circularly formed waist. HPCF has the core diameter of 200 μm and clad diameter of 230 μm. The fabricated 3 X 3 HPCF coupler has the perfect uniformity of about 0.3 dB, low insertion loss of 5.5 dB, and low excess loss of 0.8 dB, which shows excellent uniform power splitting ratio. In order to improve the transmission performance, The RGB chip LEDs were butt-coupled directly to the ferruled input ports of the coupler and packaged by TO46-can type. In the produced white color by HPCF coupler, the photometric brightness at the circular endface of outputs of HPCF coupler was in a rage of 10062 ~ 10094 cd/m2. The fiber optic white color combiner provides tunable white sources excluding heat source and having thickness of 200 μm. We also proposed a 0.44 inch LED backlight system with these fiber-optic pure white sources. With the proposed device, we obtain the improved uniformity in luminance distribution and wide color gamut by using the white light mixing red, green and blue lights.

  20. A study of optical design of power-saving backlight module with external illuminance

    NASA Astrophysics Data System (ADS)

    Fang, Yi-Chin; Tzeng, Yih-Fong

    2014-05-01

    In backlight modules, the light guide plate (LGP) is a key component for performance and also facilitates access to develop LGPs on its own. In this research, we propose a newly developed method: LEDs with freeform as a lighting source, are employed to integrate and manipulate the specially designed and optimized 3D-like pattern distribution of the micro features in order to obtain the required optical characteristics at maximal performance. In this research propose the concept of Light Guide Film(LGF) at the back side of Back Light Unit(BLU). This new design may induce the exterior light ,then improve the power-saving of existent BLU. Two design models are reseated: One is design for 14 inch LCD monitor of notebook computer, which might improve 21% compared to traditional one. Another is designed for 3.5 inch LCD for mobile phone display ,which might improve 15% compared to traditional one.

  1. New reversing design method for LED uniform illumination.

    PubMed

    Wang, Kai; Wu, Dan; Qin, Zong; Chen, Fei; Luo, Xiaobing; Liu, Sheng

    2011-07-04

    In light-emitting diode (LED) applications, it is becoming a big issue that how to optimize light intensity distribution curve (LIDC) and design corresponding optical component to achieve uniform illumination when distance-height ratio (DHR) is given. A new reversing design method is proposed to solve this problem, including design and optimization of LIDC to achieve high uniform illumination and a new algorithm of freeform lens to generate the required LIDC by LED light source. According to this method, two new LED modules integrated with freeform lenses are successfully designed for slim direct-lit LED backlighting with thickness of 10mm, and uniformities of illuminance increase from 0.446 to 0.915 and from 0.155 to 0.887 when DHRs are 2 and 3 respectively. Moreover, the number of new LED modules dramatically decreases to 1/9 of the traditional LED modules while achieving similar uniform illumination in backlighting. Therefore, this new method provides a practical and simple way for optical design of LED uniform illumination when DHR is much larger than 1.

  2. Integrated light-guide plates that can control the illumination angle for liquid crystal display backlight system

    NASA Astrophysics Data System (ADS)

    Feng, Di; Yang, Xingpeng; Jin, Guofan; Yan, Yingbai; Fan, Shoushan

    2006-01-01

    Liquid crystal displays (LCDs) with edge-lit backlight systems offer several advantages, such as low energy consuming, low weight, and high uniformity of intensity, over traditional cathode-ray tube displays, and make them ideal for many applications including monitors in notebook personal computers, screens for TV, and many portable information terminals, such as mobile phones, personal digital assistants, etc. To satisfy market requirements for mobile and personal display panels, it is more and more necessary to modify the backlight system and make it thinner, lighter, and brighter all at once. In this paper, we have proposed a new integrated LGP based on periodic and aperiodic microprism structures by using polymethyl methacrylate material, which can be designed to control the illumination angle, and to get high uniformity of intensity. So the backlight system will be simplified to use only light sources and one LGP without using other optical sheets, such as reflection sheet, diffusion sheet and prism sheets. By using optimizing program and ray tracing method, the designed LGPs can achieve a uniformity of intensity better than 86%, and get a peak illumination angle from +400 to -200, without requiring other optical sheets. We have designed a backlight system with only one LED light source and one LGP, and other LGP design examples with different sizes (1.8 inches and 14.1 inches) and different light source (LED or CCFL), are performed also.

  3. Color separation system with angularly positioned light source module for pixelized backlighting.

    PubMed

    Chen, Po-Chou; Lin, Hui-Hsiung; Chen, Cheng-Huan; Lee, Chi-Hung; Lu, Mao-Hong

    2010-01-18

    A color-separation system that angularly positions color LEDs to produce color separation and a lens array to focus this light onto the pixels is proposed. The LED rays from different incident angles are mapped into corresponding sub-pixel positions to efficiently display color image, which can be used to replace the absorbing color filter in the conventional liquid crystal layer. In this paper, the prototype backlight has been designed, fabricated and characterized. The measurement results of this module showed that a gain factor of transmission efficiency three times more than that of conventional color filters efficiency improvement and a larger color gamut are expected.

  4. Evaluation of simulation alternatives for the brute-force ray-tracing approach used in backlight design

    NASA Astrophysics Data System (ADS)

    Desnijder, Karel; Hanselaer, Peter; Meuret, Youri

    2016-04-01

    A key requirement to obtain a uniform luminance for a side-lit LED backlight is the optimised spatial pattern of structures on the light guide that extract the light. The generation of such a scatter pattern is usually performed by applying an iterative approach. In each iteration, the luminance distribution of the backlight with a particular scatter pattern is analysed. This is typically performed with a brute-force ray-tracing algorithm, although this approach results in a time-consuming optimisation process. In this study, the Adding-Doubling method is explored as an alternative way for evaluating the luminance of a backlight. Due to the similarities between light propagating in a backlight with extraction structures and light scattering in a cloud of light scatterers, the Adding-Doubling method which is used to model the latter could also be used to model the light distribution in a backlight. The backlight problem is translated to a form upon which the Adding-Doubling method is directly applicable. The calculated luminance for a simple uniform extraction pattern with the Adding-Doubling method matches the luminance generated by a commercial raytracer very well. Although successful, no clear computational advantage over ray tracers is realised. However, the dynamics of light propagation in a light guide as used the Adding-Doubling method, also allow to enhance the efficiency of brute-force ray-tracing algorithms. The performance of this enhanced ray-tracing approach for the simulation of backlights is also evaluated against a typical brute-force ray-tracing approach.

  5. Issues and solutions: opportunities for European LED manufacturers

    NASA Astrophysics Data System (ADS)

    Pearsall, T. P.

    2007-09-01

    Marketing studies by EPIC show significant revenue opportunities by 2012 for UHB-LEDs in the automotive, LCD backlighting, and architectural lighting sectors. The goal of this workshop on manufacturing issues is to consider five key issues for UHB-LED manufacturing and to propose solutions that will pave the way to full exploitation of the opportunities.

  6. Fluorescent protein integrated white LEDs for displays

    NASA Astrophysics Data System (ADS)

    Press, Daniel Aaron; Melikov, Rustamzhon; Conkar, Deniz; Nur Firat-Karalar, Elif; Nizamoglu, Sedat

    2016-11-01

    The usage time of displays (e.g., TVs, mobile phones, etc) is in general shorter than their functional life time, which worsens the electronic waste (e-waste) problem around the world. The integration of biomaterials into electronics can help to reduce the e-waste problem. In this study, we demonstrate fluorescent protein integrated white LEDs to use as a backlight source for liquid crystal (LC) displays for the first time. We express and purify enhanced green fluorescent protein (eGFP) and monomeric Cherry protein (mCherry), and afterward we integrate these proteins as a wavelength-converter on a blue LED chip. The protein-integrated backlight exhibits a high luminous efficacy of 248 lm/Wopt and the area of the gamut covers 80% of the NTSC color gamut. The resultant colors and objects in the image on the display can be well observed and distinguished. Therefore, fluorescent proteins show promise for display applications.

  7. Review – Quantum Dots and Their Application in Lighting, Displays, and Biology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frecker, Talitha; Bailey, Danielle; Arzeta-Ferrer, Xochitl

    2015-08-18

    In this review, we focus on the advancement of white light emitting nanocrystals, their usage as the emissive layer in LEDs and display backlights, and examine the increased efficiency and longevity of quantum dots based colored LEDs. In addition, we also explore recent discoveries on quantum dots as biological labels, dynamic trackers, and applications in drug delivery.

  8. Design considerations for a backlight with switchable viewing angles

    NASA Astrophysics Data System (ADS)

    Fujieda, Ichiro; Takagi, Yoshihiko; Rahadian, Fanny

    2006-08-01

    Small-sized liquid crystal displays are widely used for mobile applications such as cell phones. Electronic control of a viewing angle range is desired in order to maintain privacy for viewing in public as well as to provide wide viewing angles for solitary viewing. Conventionally, a polymer-dispersed liquid crystal (PDLC) panel is inserted between a backlight and a liquid crystal panel. The PDLC layer either transmits or scatters the light from the backlight, thus providing an electronic control of viewing angles. However, such a display system is obviously thick and expensive. Here, we propose to place an electronically-controlled, light-deflecting device between an LED and a light-guide of a backlight. For example, a liquid crystal lens is investigated for other applications and its focal length is controlled electronically. A liquid crystal phase grating either transmits or diffracts an incoming light depending on whether or not a periodic phase distribution is formed inside its liquid crystal layer. A bias applied to such a device will control the angular distribution of the light propagating inside a light-guide. Output couplers built in the light-guide extract the propagating light to outside. They can be V-shaped grooves, pyramids, or any other structures that can refract, reflect or diffract light. When any of such interactions occur, the output couplers translate the changes in the propagation angles into the angular distribution of the output light. Hence the viewing-angle characteristic can be switched. The designs of the output couplers and the LC devices are important for such a backlight system.

  9. Green emitting phosphors and blends thereof

    DOEpatents

    Setlur, Anant Achyut; Siclovan, Oltea Puica; Nammalwar, Prasanth Kumar; Sathyanarayan, Ramesh Rao; Porob, Digamber G.; Chandran, Ramachandran Gopi; Heward, William Jordan; Radkov, Emil Vergilov; Briel, Linda Jane Valyou

    2010-12-28

    Phosphor compositions, blends thereof and light emitting devices including white light emitting LED based devices, and backlights, based on such phosphor compositions. The devices include a light source and a phosphor material as described. Also disclosed are phosphor blends including such a phosphor and devices made therefrom.

  10. Low-intensity calibration source for optical imaging systems

    NASA Astrophysics Data System (ADS)

    Holdsworth, David W.

    2017-03-01

    Laboratory optical imaging systems for fluorescence and bioluminescence imaging have become widely available for research applications. These systems use an ultra-sensitive CCD camera to produce quantitative measurements of very low light intensity, detecting signals from small-animal models labeled with optical fluorophores or luminescent emitters. Commercially available systems typically provide quantitative measurements of light output, in units of radiance (photons s-1 cm-2 SR-1) or intensity (photons s-1 cm-2). One limitation to current systems is that there is often no provision for routine quality assurance and performance evaluation. We describe such a quality assurance system, based on an LED-illuminated thin-film transistor (TFT) liquid-crystal display module. The light intensity is controlled by pulse-width modulation of the backlight, producing radiance values ranging from 1.8 x 106 photons s-1 cm-2 SR-1 to 4.2 x 1013 photons s-1 cm-2 SR-1. The lowest light intensity values are produced by very short backlight pulses (i.e. approximately 10 μs), repeated every 300 s. This very low duty cycle is appropriate for laboratory optical imaging systems, which typically operate with long-duration exposures (up to 5 minutes). The low-intensity light source provides a stable, traceable radiance standard that can be used for routine quality assurance of laboratory optical imaging systems.

  11. Peak wavelength shifts and opponent color theory

    NASA Astrophysics Data System (ADS)

    Ashdown, Ian; Salsbury, Marc

    2007-09-01

    We adapt the tenets of Hering's opponent color theory to the processing of data obtained from a tristimulus colorimeter to independently determine the intensity and possible peak wavelength shift of a narrowband LED. This information may then be used for example in an optical feedback loop to maintain constant intensity and chromaticity for a light source consisting of two LEDs with different peak wavelengths. This approach is particularly useful for LED backlighting of LCD display panels using red, green, and blue LEDs, wherein a tristimulus colorimeter can be used to maintain primary chromaticities to within broadcast standard limits in real time.

  12. Masked-backlighter technique used to simultaneously image x-ray absorption and x-ray emission from an inertial confinement fusion plasma.

    PubMed

    Marshall, F J; Radha, P B

    2014-11-01

    A method to simultaneously image both the absorption and the self-emission of an imploding inertial confinement fusion plasma has been demonstrated on the OMEGA Laser System. The technique involves the use of a high-Z backlighter, half of which is covered with a low-Z material, and a high-speed x-ray framing camera aligned to capture images backlit by this masked backlighter. Two strips of the four-strip framing camera record images backlit by the high-Z portion of the backlighter, while the other two strips record images aligned with the low-Z portion of the backlighter. The emission from the low-Z material is effectively eliminated by a high-Z filter positioned in front of the framing camera, limiting the detected backlighter emission to that of the principal emission line of the high-Z material. As a result, half of the images are of self-emission from the plasma and the other half are of self-emission plus the backlighter. The advantage of this technique is that the self-emission simultaneous with backlighter absorption is independently measured from a nearby direction. The absorption occurs only in the high-Z backlit frames and is either spatially separated from the emission or the self-emission is suppressed by filtering, or by using a backlighter much brighter than the self-emission, or by subtraction. The masked-backlighter technique has been used on the OMEGA Laser System to simultaneously measure the emission profiles and the absorption profiles of polar-driven implosions.

  13. Reduced-thickness backlighter for autostereoscopic display and display using the backlighter

    NASA Technical Reports Server (NTRS)

    Eichenlaub, Jesse B (Inventor); Gruhlke, Russell W (Inventor)

    1999-01-01

    A reduced-thickness backlighter for an autostereoscopic display is disclosed having a lightguide and at least one light source parallel to an edge of the lightguide so as to be substantially coplanar with the lightguide. The lightguide is provided with a first surface which has a plurality of reflective linear regions, such as elongated grooves or glossy lines, parallel to the illuminated edge of the lightguide. Preferably the lightguide further has a second surface which has a plurality of lenticular lenses for reimaging the reflected light from the linear regions into a series of thin vertical lines outside the guide. Because of the reduced thickness of the backlighter system, autostereoscopic viewing is enabled in applications requiring thin backlighter systems. In addition to taking up less space, the reduced-thickness backlighter uses less lamps and less power. For accommodating 2-D applications, a 2-D diffuser plate or a 2-D lightguide parallel to the 3-D backlighter is disclosed for switching back and forth between 3-D viewing and 2-D viewing.

  14. 76 FR 56796 - In the Matter of Certain Devices for Improving Uniformity Used in a Backlight Module and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-14

    ... Taiwan and ITRI International Inc. of San Jose, California. A letter supplementing the complaint was... (``the `932 patent''). The complaint further alleges that an industry in the United States exists as... patent, and whether an industry in the United States exists as required by subsection (a)(2) of section...

  15. Smartphone based Tomographic PIV using colored shadows

    NASA Astrophysics Data System (ADS)

    Aguirre-Pablo, Andres A.; Alarfaj, Meshal K.; Li, Er Qiang; Thoroddsen, Sigurdur T.

    2016-11-01

    We use low-cost smartphones and Tomo-PIV, to reconstruct the 3D-3C velocity field of a vortex ring. The experiment is carried out in an octagonal tank of water with a vortex ring generator consisting of a flexible membrane enclosed by a cylindrical chamber. This chamber is pre-seeded with black polyethylene microparticles. The membrane is driven by an adjustable impulsive air-pressure to produce the vortex ring. Four synchronized smartphone cameras, of 40 Mpx each, are used to capture the location of particles from different viewing angles. We use red, green and blue LED's as backlighting sources, to capture particle locations at different times. The exposure time on the smartphone cameras are set to 2 seconds, while exposing each LED color for about 80 μs with different time steps that can go below 300 μs. The timing of these light pulses is controlled with a digital delay generator. The backlight is blocked by the instantaneous location of the particles in motion, leaving a shadow of the corresponding color for each time step. The image then is preprocessed to separate the 3 different color fields, before using the MART reconstruction and cross-correlation of the time steps to obtain the 3D-3C velocity field. This proof of concept experiment represents a possible low-cost Tomo-PIV setup.

  16. Design of a backlighting structure for very large-area luminaries

    NASA Astrophysics Data System (ADS)

    Carraro, L.; Mäyrä, A.; Simonetta, M.; Benetti, G.; Tramonte, A.; Benedetti, M.; Randone, E. M.; Ylisaukko-Oja, A.; Keränen, K.; Facchinetti, T.; Giuliani, G.

    2017-02-01

    A novel approach for RGB semiconductor LED-based backlighting system is developed to satisfy the requirements of the Project LUMENTILE funded by the European Commission, whose scope is to develop a luminous electronic tile that is foreseen to be manufactured in millions of square meters each year. This unconventionally large-area surface of uniform, high-brightness illumination requires a specific optical design to keep a low production cost, while maintaining high optical extraction efficiency and a reduced thickness of the structure, as imposed by architectural design constraints. The proposed solution is based on a light-guiding layer to be illuminated by LEDs in edge configuration, or in a planar arrangement. The light guiding slab is finished with a reflective top interface and a diffusive or reflective bottom interface/layer. Patterning is used for both the top interface (punctual removal of reflection and generation of a light scattering centers) and for the bottom layer (using dark/bright printed pattern). Computer-based optimization algorithms based on ray-tracing are used to find optimal solutions in terms of uniformity of illumination of the top surface and overall light extraction efficiency. Through a closed-loop optimization process, that assesses the illumination uniformity of the top surface, the algorithm generates the desired optimized top and bottom patterns, depending on the number of LED sources used, their geometry, and the thickness of the guiding layer. Specific low-cost technologies to realize the patterning are discussed, with the goal of keeping the production cost of these very large-area luminaries below the value of 100$/sqm.

  17. Fabrication and performance study of light guide plate for LCD backlight based on quantum-dot scattering microstructure array

    NASA Astrophysics Data System (ADS)

    Xie, Hongxing; Huang, Jiamin; Ye, Yun; Chen, Enguo; Xu, Sheng

    2017-10-01

    Light Guide Plate (LGP) plays an irreplaceable role in Liquid Crystal Display (LCD) backlight. LGP with quantum-dot (QD) shows promise in the development of next-generation displays because of QDs' beneficial characteristics. In this paper, we present a novel QD LGP for LCD backlight based on QD scattering microstructure array (SMA), in which the QD net dots are located discretely and arranged in arrays on the bottom surface of LGP. The paper first introduces the QD backlight briefly, then discusses the preparation and fabrication process of the proposed prototype, and finally presents a systematic photometric approach to reveal the remarkable advantages of QD backlight. The white-balance is achieved by adjusting the proportion of the QDs in the mixture and optimizing the R-QD / G-QD ratio. The apparent morphology of QD SMA is characterized by OLYMPUS laser microscope, while the optical properties of QD backlight are investigated by F-4600 fluorescence spectrophotometer and SRC-200M spectrum color luminance meter, respectively. Experimental results show that the white balance can be achieved when the QDs account for a certain proportion about 7% within the mixture, and the ratio of R-QD / G-QD is optimized to about 1:12. The proposed system offers an alternative and feasible method for fabricating QD backlight, which may have great application prospects in the future.

  18. Spectral measurements of asymmetrically irradiated capsule backlighters

    DOE PAGES

    Keiter, P. A.; Drake, R. P.

    2016-09-09

    Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies. Ideally one irradiates the capsule backlighter symmetrically, however, in complex experimental geometries, this is not always possible. In recent experiments we irradiated capsule backlighters asymmetrically and measured the x-ray spectrum from multiple directions. We will present time-integrated spectra over the photon energy range of ~2-13 keV and time-resolved spectra over the photon energy range of ~2-3 keV. Lastly, we will compare the spectra from different lines of sight to determine if the laser asymmetry results in an angular dependence in the x-ray emission.

  19. Light sources and output couplers for a backlight with switchable emission angles

    NASA Astrophysics Data System (ADS)

    Fujieda, Ichiro; Imai, Keita; Takagi, Yoshihiko

    2007-09-01

    For switching viewing angles of a liquid crystal display, we proposed to place a liquid crystal device between an LED and a light-guide of a backlight. The first key component for this configuration is a light source with electronically-controlled emission angles. Here, we construct such a device by stacking an optical film and a polymer-network liquid crystal (PNLC) cell on top of a chip-type LED. The optical film contains opaque parallel plates that limit the LED output in a narrow angular range. The PNLC cell either transmits or scatters the light emerging from the optical film. Experiment using a 15μm-thick PNLC cell shows that the angular distribution becomes 2.3 times wider by turning off the PNLC cell. We place this light source at one end of a light-guide so that the angular distribution of the light propagating inside is controlled. The second key component is some types of micro-strucrures built on the light-guide to out-couple the propagating light. We first attached various optical films on a light-guide surface. Although the angular distribution of the extracted light was switched successfully, light was mostly emitted into an oblique direction, approximately 60° from the plane normal. Next, we used a half-cylinder in place of the optical films. The curved surface of the cylinder was attached to the light-guide with a small amount of matching oil, which constituted an optical window. We measured that the angular distribution of the extracted light decreased to 35° FWHM from 62° FWHM by turning on the PNLC cell.

  20. Development of multi-touch panel backlight system

    NASA Astrophysics Data System (ADS)

    Chomiczewski, J.; Długosz, M.; Godlewski, G.; Kochanowicz, M.

    2013-10-01

    The paper presents design, simulation analysis, and measurements of parameters of optical multi touch panel backlight system. Comparison of optical technology with commercially available solutions was also performed. The numerical simulation of laser based backlight system was made. The influence of the laser power, beam divergence, and placing reflective surfaces on the uniformity of illumination were examined. Optimal illumination system was used for further studies.

  1. Analysis of a color-matching backlight system using a blazed grating and a lenticular lens array.

    PubMed

    Son, Chang-Gyun; Gwag, Jin Seok; Lee, Jong Hoon; Kwon, Jin Hyuk

    2012-12-20

    A high efficiency LCD employing a color-matching backlight system that consists of a collimation lenticular lens sheet, a blazed grating, and a focusing lenticular lens array is proposed and analyzed. The RGB lights that are collimated and dispersed from the collimation lenticular lens sheet and the blazed grating are incident on the RGB color filters by the focusing lenticular lens array. The color-matched transmittance was increased 183% and 121% for divergence angles of 2° and 11°, respectively, compared to a conventional backlight that does not use a blazed grating. The design, simulation, and experimental results for the prototype color-matching backlight system are presented.

  2. Lightweight compact 2D/3D autostereoscopic LCD backlight for games, monitor, and notebook applications

    NASA Astrophysics Data System (ADS)

    Eichenlaub, Jesse B.

    1998-04-01

    At the 1997 conference DTI first reported on a low cost, thin, lightweight backlight for LCDs that generates a special illumination pattern to create autostereoscopic 3D images and can switch to conventional diffuse illumination for 2D images. The backlight is thin and efficient enough for use in portable computer and hand held games, as well as thin desktop displays. The system has been embodied in 5' (13 cm) diagonal backlights for gambling machines, and in the 12.1' (31 cm) diagonal DTI Virtual Window(TM) desktop product. During the past year, DTI has improved the technology considerably, reducing crosstalk, increasing efficiency, improving components for mass production, and developing prototypes that move the 3D viewing zones in response to the observer's head position. The paper will describe the 2D/3D backlights, improvements that have been made to their function, and their embodiments within the latest display products and prototypes.

  3. Blue laser diode (LD) and light emitting diode (LED) applications

    NASA Astrophysics Data System (ADS)

    Bergh, Arpad A.

    2004-09-01

    The family of blue LEDs, edge emitting and surface emitting lasers, enable a number of applications. Blue lasers are used in digital applications such as optical storage in high density DVDs. The resolution of the spot size and hence the storage density is diffraction limited and is inversely proportional to the square of the wavelength of the laser. Other applications include printing, optical scanners, and high-resolution photo-lithography.As light emitters, blue LEDs are used for signaling and in direct view large area emissive displays. They are also making inroads into signage and LCD back-lighting, mobile platforms, and decorative accent lighting in curtains, furniture, etc.Blue LEDs produce white light either with phosphor wavelength converters or in combination with red and green LEDs. The full potential of LED light sources will require three devices to enable complete control over color and intensity.Sensing and medical/bio applications have a major impact on home security, on monitoring the environment, and on health care. New emerging diagnostic and therapeutic applications will improve the quality and reduce the cost of health care.

  4. X-ray backlighting of imploding aluminium liners on PTS facility

    NASA Astrophysics Data System (ADS)

    Yang, Qingguo; Liu, Dongbing; Mu, Jian; Huang, Xianbin; Dan, Jiakun; Xie, Xudong; Deng, Wu; Feng, Shuping; Wang, Meng; Ye, Yan; Peng, Qixian; Li, Zeren

    2016-09-01

    The x-ray backlighting systems, including a 1.865 keV (Si Heα line) spherically bent crystal imaging system and an ˜8.3 keV (Cu Heα line) point-projection imaging system, newly fielded on the Primary Test Stand facility are introduced and its preliminary experimental results in radiography of the aluminium (Al) liners with seeded sinusoidal perturbations are presented. The x-ray backlighter source is created using a 1 TW, 1 kJ Nd: glass high power laser, kilo-joule laser system, recently constructed at China Academy of Engineering Physics. The ablation melt and instability of the imploding Al liner outer edge under the driving current of ˜7.5 MA are successfully observed using these two backlighting systems, respectively.

  5. Laser backlight unit based on a leaky optical fiber

    NASA Astrophysics Data System (ADS)

    Okuda, Yuuto; Onoda, Kousuke; Fujieda, Ichiro

    2012-07-01

    A backlight unit is constructed by laying out an optical fiber on a two-dimensional plane and letting the light leak out in a controlled manner. In experiment, we formed multiple grooves on the surface of a plastic optical fiber by pressing a heated knife edge. The depth of the groove determined the percentage of the optical power leaking out. The optical fiber with multiple grooves was embedded in an acrylic plate with a spiral trench, and a diffuser sheet was placed over it. When we injected laser light into the end of the optical fiber, this configuration successfully worked as an area illuminator. However, the coherent nature of the laser light caused severe speckle noise. We evaluated the speckle contrast under darkness, and it varied from 80% to 23%, depending on the lens aperture used to capture the images of the illuminator. We glued an ultrasound generator to the optical fiber to introduce phase modulation for the light propagating inside the optical fiber. In this way, the speckle contrast was reduced by a factor of seven to four. Under room lighting, the speckle noise was made barely noticeable by turning on the ultrasound generator.

  6. Exploration of the fragmentation of laser shock-melted aluminum using x-ray backlighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Lin, E-mail: zhanglinbox@263.net, E-mail: zhanglinbox@caep.cn; Li, Ying-Hua; Li, Xue-Mei

    The fragmentation of shock-melted metal material is an important scientific problem in shock physics and is suitable for experimentally investigating by the laser-driven x-ray backlighting technique. This letter reports on the exploration of laser shock-melted aluminum fragmentation by means of x-ray backlighting at the SGII high energy facility in China. High-quality and high-resolution radiographs with negligible motion blur were obtained and these images enabled analysis of the mass distribution of the fragmentation product.

  7. Side-emitting illuminators using LED sources

    NASA Astrophysics Data System (ADS)

    Zhao, Feng; Van Derlofske, John F.

    2003-11-01

    This study investigates illuminators composed of light emitting diode (LED) array sources and side-emitting light guides to provide efficient general illumination. Specifically, new geometries are explored to increase the efficiency of current systems while maintaining desired light distribution. LED technology is already successfully applied in many illumination applications, such as traffic signals and liquid crystal display (LCD) backlighting. It provides energy-efficient, small-package, long-life, and color-adjustable illumination. However, the use of LEDs in general illumination is still in its early stages. Current side-emitting systems typically use a light guide with light sources at one end, an end-cap surface at the other end, and light releasing sidewalls. This geometry introduces efficiency loss that can be as high as 40%. The illuminators analyzed in this study use LED array sources along the longitude of a light guide to increase the system efficiency. These new geometries also provide the freedom of elongating the system without sacrificing system efficiency. In addition, alternative geometries can be used to create white light with monochromatic LED sources. As concluded by this study, the side-emitting illuminators using LED sources gives the possibility of an efficient, distribution-controllable linear lighting system.

  8. Numerical analysis of lateral illumination lightpipes using elliptical grooves

    NASA Astrophysics Data System (ADS)

    Sánchez-Guerrero, Guillermo E.; Viera-González, Perla M.; Martínez-Guerra, Edgar; Ceballos-Herrera, Daniel E.

    2017-09-01

    Lightpipes are used for illumination in applications such as back-lighting or solar cell concentrators due to the high irradiance uniformity, but its optimal design requires several parameters. This work presents a procedure to design a square lightpipe to control the light-extraction on its lateral face using commercial LEDs placed symmetrically in the lightpipe frontal face. We propose the use of grooves using total internal reflection placed successively in the same face of extraction to control the area of emission. The LED area of emission is small compared with the illuminated area, and, as expected, the lateral face total power is attenuated. These grooves reduce the optical elements in the system and can control areas of illumination. A mathematical and numerical analysis are presented to determine the dependencies on the light-extraction.

  9. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility

    NASA Astrophysics Data System (ADS)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; Harding, E. C.; Jennings, C. A.; Lamppa, D. C.; Loisel, G. P.; Martin, M. R.; Robertson, G. K.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Weis, M. R.; Porter, J. L.; McBride, R. D.

    2017-10-01

    Many experiments on Sandia National Laboratories' Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α ) or 6.151 keV (Mn He α ) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [ C R = r i ( 0 ) / r i ( t ) ] using the 6.151-keV backlighter system were too opaque to identify the inner radius r i of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

  10. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia’s Z Pulsed Power Facility

    DOE PAGES

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; ...

    2017-10-10

    Many experiments on Sandia National Laboratories’ Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α) or 6.151 keV (Mn He α) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios C R above 15 [C R=r i(0)/r i(t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the linermore » with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (C R about 4-5), high-areal-density liner implosions.« less

  11. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia’s Z Pulsed Power Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.

    Many experiments on Sandia National Laboratories’ Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α) or 6.151 keV (Mn He α) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios C R above 15 [C R=r i(0)/r i(t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the linermore » with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (C R about 4-5), high-areal-density liner implosions.« less

  12. Dynamics of backlight luminance for using smartphone in dark environment

    NASA Astrophysics Data System (ADS)

    Na, Nooree; Jang, Jiho; Suk, Hyeon-Jeong

    2014-02-01

    This study developed dynamic backlight luminance, which gradually changes as time passes for comfortable use of a smartphone display in a dark environment. The study was carried out in two stages. In the first stage, a user test was conducted to identify the optimal luminance by assessing the facial squint level, subjective glare evaluation, eye blink frequency and users' subjective preferences. Based on the results of the user test, the dynamics of backlight luminance was designed. It has two levels of luminance: the optimal level for initial viewing to avoid sudden glare or fatigue to users' eyes, and the optimal level for constant viewing, which is comfortable, but also bright enough for constant reading of the displayed material. The luminance for initial viewing starts from 10 cd/m2, and it gradually increases to 40 cd/m2 for users' visual comfort at constant viewing for 20 seconds; In the second stage, a validation test on dynamics of backlight luminance was conducted to verify the effectiveness of the developed dynamics. It involving users' subjective preferences, eye blink frequency, and brainwave analysis using the electroencephalogram (EEG) to confirm that the proposed dynamic backlighting enhances users' visual comfort and visual cognition, particularly for using smartphones in a dark environment.

  13. LED-based high-speed visible light communications

    NASA Astrophysics Data System (ADS)

    Chi, Nan; Shi, Meng; Zhao, Yiheng; Wang, Fumin; Shi, Jianyang; Zhou, Yingjun; Lu, Xingyu; Qiao, Liang

    2018-01-01

    We are seeing a growing use of light emitting diodes (LEDs) in a range of applications including lighting, TV and backlight board screen, display etc. In comparison with the traditional incandescent and fluorescent light bulbs, LEDs offer long life-space, much higher energy efficiency, high performance cost ratio and above all very fast switching capability. LED based Visible Light Communications (VLC) is an emerging field of optical communications that focuses on the part of the electromagnetic spectrum that humans can see. Depending on the transmission distance, we can divide the whole optical network into two categories, long haul and short haul. Visible light communication can be a promising candidate for short haul applications. In this paper, we outline the configuration of VLC, its unique benefits, and describe the state of the art research contributions consisting of advanced modulation formats including adaptive bit loading OFDM, carrierless amplitude and phase (CAP), pulse amplitude modulation (PAM) and single carrier Nyquist, linear equalization and nonlinear distortion mitigation based on machine learning, quasi-balanced coding and phase-shifted Manchester coding. These enabling technologies can support VLC up to 10Gb/s class free space transmission.

  14. Subjective quality of video sequences rendered on LCD with local backlight dimming at different lighting conditions

    NASA Astrophysics Data System (ADS)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.; Bech, Søren; Andersen, Jakob Dahl; Forchhammer, Søren

    2015-01-01

    This paper focuses on the influence of ambient light on the perceived quality of videos displayed on Liquid Crystal Display (LCD) with local backlight dimming. A subjective test assessing the quality of videos with two backlight dimming methods and three lighting conditions, i.e. no light, low light level (5 lux) and higher light level (60 lux) was organized to collect subjective data. Results show that participants prefer the method exploiting local dimming possibilities to the conventional full backlight but that this preference varies depending on the ambient light level. The clear preference for one method at the low light conditions decreases at the high ambient light, confirming that the ambient light significantly attenuates the perception of the leakage defect (light leaking through dark pixels). Results are also highly dependent on the content of the sequence, which can modulate the effect of the ambient light from having an important influence on the quality grades to no influence at all.

  15. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tommasini, R.; Bailey, C.; Bradley, D. K.

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV,more » of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.« less

  16. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Tommasini, R.; Bailey, C.; Bradley, D. K.; Bowers, M.; Chen, H.; Di Nicola, J. M.; Di Nicola, P.; Gururangan, G.; Hall, G. N.; Hardy, C. M.; Hargrove, D.; Hermann, M.; Hohenberger, M.; Holder, J. P.; Hsing, W.; Izumi, N.; Kalantar, D.; Khan, S.; Kroll, J.; Landen, O. L.; Lawson, J.; Martinez, D.; Masters, N.; Nafziger, J. R.; Nagel, S. R.; Nikroo, A.; Okui, J.; Palmer, D.; Sigurdsson, R.; Vonhof, S.; Wallace, R. J.; Zobrist, T.

    2017-05-01

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV, of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.

  17. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    DOE PAGES

    Tommasini, R.; Bailey, C.; Bradley, D. K.; ...

    2017-05-09

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV,more » of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.« less

  18. The potential influence of LED lighting on mental illness.

    PubMed

    Bauer, Michael; Glenn, Tasha; Monteith, Scott; Gottlieb, John F; Ritter, Philipp S; Geddes, John; Whybrow, Peter C

    2018-02-01

    Two recent scientific breakthroughs may alter the treatment of mental illness, as discussed in this narrative review. The first was the invention of white light-emitting diodes (LEDs), which enabled an ongoing, rapid transition to energy-efficient LEDs for lighting, and the use of LEDs to backlight digital devices. The second was the discovery of melanopsin-expressing photosensitive retinal ganglion cells, which detect environmental irradiance and mediate non-image forming (NIF) functions including circadian entrainment, melatonin secretion, alertness, sleep regulation and the pupillary light reflex. These two breakthroughs are interrelated because unlike conventional lighting, white LEDs have a dominant spectral wavelength in the blue light range, near the peak sensitivity for the melanopsin system. Pertinent articles were identified. Blue light exposure may suppress melatonin, increase alertness, and interfere with sleep in young, healthy volunteers and in animals. Areas of concern in mental illness include the influence of blue light on sleep, other circadian-mediated symptoms, prescribed treatments that target the circadian system, measurement using digital apps and devices, and adolescent sensitivity to blue light. While knowledge in both fields is expanding rapidly, future developments must address the potential impact of blue light on NIF functions for healthy individuals and those with mental illness.

  19. Crystal and source characterization for the Crystal Backlighter Imager capability at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Krauland, C. M.; Hall, G. N.; Buscho, J. G.; Hibbard, R.; McCarville, T. J.; Lowe-Webb, R.; Ayers, S. L.; Kalantar, D.; Kohut, T.; Kemp, G. E.; Bradley, D. K.; Bell, P.; Landen, O. L.; Brewster, T. N.; Piston, K.

    2017-10-01

    The Crystal Backlighter Imager (CBI) is a very narrow bandwidth ( 10 eV) x-ray radiography system that uses Bragg reflection from a spherically-curved crystal at near normal incidence. This diagnostic has the capability to image late in an ICF implosion because it only requires the brightness of the backlighter to be larger than the capsule self-emission in that narrow bandwidth. While the limited bandwidth is advantageous for this reason, it also requires that the effective energy of the backlighter atomic line is known to 1 eV accuracy for proper crystal alignment. Any Doppler shift in the line energy must be understood for the imaging system to work. The work presented details characterization experiments done at the Jupiter Laser Facility with a Si (8 6 2) crystal that will be used with a Selenium backlighter in the NIF CBI diagnostic. We used the spherically-bent crystals to image a small ( 200 µm) He α source generated by the Janus laser on a Se foil. Scanning Bragg angles over multiple shots allowed us to map out the spectral line intensity distribution for optimal alignment in NIF. A subsequent Doppler shift measurement using CBI on NIF will also be presented with complementary HYDRA modeling for both experiments. Prepared by LLNL under Contract DE-AC52-07NA27344 and by General Atomics under Contract DE-NA0001808.

  20. Ultraviolet excitation of remote phosphor with symmetrical illumination used in dual-sided liquid-crystal display.

    PubMed

    Huang, Hsin-Tao; Tsai, Chuang-Chuang; Huang, Yi-Pai

    2010-08-01

    The UV-excited flat lighting (UFL) technique differs from conventional fluorescent lamp or LED illumination. It involves using a remote phosphor film to convert the wavelength of UV light to visible light, achieving high brightness and planar and uniform illumination. In particular, UFL can accomplish compact size, low power consumption, and symmetrical dual-sided illumination. Additionally, UFL utilizes a thermal radiation mechanism to release the large amount of heat that is generated upon illumination without thermal accumulation. These characteristics of the UFL technique can motivate a wide range of lighting applications in thin-film transistor LCD backlighting or general lighting.

  1. Realizing Rec. 2020 color gamut with quantum dot displays.

    PubMed

    Zhu, Ruidong; Luo, Zhenyue; Chen, Haiwei; Dong, Yajie; Wu, Shin-Tson

    2015-09-07

    We analyze how to realize Rec. 2020 wide color gamut with quantum dots. For photoluminescence, our simulation indicates that we are able to achieve over 97% of the Rec. 2020 standard with quantum dots by optimizing the emission spectra and redesigning the color filters. For electroluminescence, by optimizing the emission spectra of quantum dots is adequate to render over 97% of the Rec. 2020 standard. We also analyze the efficiency and angular performance of these devices, and then compare results with LCDs using green and red phosphors-based LED backlight. Our results indicate that quantum dot display is an outstanding candidate for achieving wide color gamut and high optical efficiency.

  2. A perspective perception on the applications of light-emitting diodes.

    PubMed

    Nair, Govind B; Dhoble, S J

    2015-12-01

    Light-emitting diodes (LEDs) continue to penetrate the global market; their pervasiveness clearly being felt in such diverse fields as technological, socio-economic and commercial interests. The multi-billion dollar LED market is shared by various segments, including office and household lighting, street lighting, the automobile industry, traffic signals, backlighting for hand-held devices, indoor and outdoor signs and indicators, medicine, communication systems, crop cultivation using artificial light and many more. The technological development of LEDs has undergone many phases in different parts of the world. From the early discovery of luminescence to the invention of highly efficient organic LEDs, researchers have worked with the prime purpose of improving the performance of luminaires. The need to infuse the market with more efficient and cheaper products has been prevalent from the start. LEDs are a result of this uncontrolled desire of researchers to develop superior products that would displace existing products in the market. To understand what led to the current prominence of LEDs, we give a brief historical overview of the field followed by a thorough discussion of the positive features of LEDs. This work includes the basic requirements, advantages and disadvantages of LEDs in a variety of applications. A brief description of the diverse applications of LED in fields such as lighting, indicators and displays, farming, medicine and communication is given. Considerable importance is placed on discussing the possible difficulties that must be overcome before using LEDs in commercial applications. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Streaked x-ray backlighting with twin-slit imager for study of density profile and trajectory of low-density foam target filled with deuterium liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiraga, H.; Mahigashi, N.; Yamada, T.

    2008-10-15

    Low-density plastic foam filled with liquid deuterium is one of the candidates for inertial fusion target. Density profile and trajectory of 527 nm laser-irradiated planer foam-deuterium target in the acceleration phase were observed with streaked side-on x-ray backlighting. An x-ray imager employing twin slits coupled to an x-ray streak camera was used to simultaneously observe three images of the target: self-emission from the target, x-ray backlighter profile, and the backlit target. The experimentally obtained density profile and trajectory were in good agreement with predictions by one-dimensional hydrodynamic simulation code ILESTA-1D.

  4. Small-Size High-Current Generators for X-Ray Backlighting

    NASA Astrophysics Data System (ADS)

    Chaikovsky, S. A.; Artyomov, A. P.; Zharova, N. V.; Zhigalin, A. S.; Lavrinovich, I. V.; Oreshkin, V. I.; Ratakhin, N. A.; Rousskikh, A. G.; Fedunin, A. V.; Fedushchak, V. F.; Erfort, A. A.

    2017-12-01

    The paper deals with the soft X-ray backlighting based on the X-pinch as a powerful tool for physical studies of fast processes. Proposed are the unique small-size pulsed power generators operating as a low-inductance capacitor bank. These pulse generators provide the X-pinch-based soft X-ray source (hν = 1-10 keV) of micron size at 2-3 ns pulse duration. The small size and weight of pulse generators allow them to be transported to any laboratory for conducting X-ray backlighting of test objects with micron space resolution and nanosecond exposure time. These generators also allow creating synchronized multi-frame radiographic complexes with frame delay variation in a broad range.

  5. Guidelines for application of fluorescent lamps in high-performance avionic backlight systems

    NASA Astrophysics Data System (ADS)

    Syroid, Daniel D.

    1997-07-01

    Fluorescent lamps have proven to be well suited for use in high performance avionic backlight systems as demonstrated by numerous production applications for both commercial and military cockpit displays. Cockpit display applications include: Boeing 777, new 737s, F-15, F-16, F-18, F-22, C- 130, Navy P3, NASA Space Shuttle and many others. Fluorescent lamp based backlights provide high luminance, high lumen efficiency, precision chromaticity and long life for avionic active matrix liquid crystal display applications. Lamps have been produced in many sizes and shapes. Lamp diameters range from 2.6 mm to over 20 mm and lengths for the larger diameter lamps range to over one meter. Highly convoluted serpentine lamp configurations are common as are both hot and cold cathode electrode designs. This paper will review fluorescent lamp operating principles, discuss typical requirements for avionic grade lamps, compare avionic and laptop backlight designs and provide guidelines for the proper application of lamps and performance choices that must be made to attain optimum system performance considering high luminance output, system efficiency, dimming range and cost.

  6. A 7.2 keV spherical crystal backlighter system for Sandia's Z Pulsed Power Facility

    NASA Astrophysics Data System (ADS)

    Schollmeier, M.; Knapp, P. F.; Ampleford, D. J.; Loisel, G. P.; Robertson, G.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Porter, J. L.; McBride, R. D.

    2016-10-01

    Many experiments on Sandia's Z facility, a 30 MA, 100 ns rise-time, pulsed-power driver, use a monochromatic Quartz crystal imaging backlighter system at 1.865 keV (Si Heα) or 6.151 keV (Mn Heα) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array. The x-ray source is generated by the Z-Beamlet Laser (ZBL), which provides up to 4.5 kJ at 527 nm during a 6 ns window. Radiographs of an imploding thick-walled Beryllium liner at a convergence ratio of about 20 [CR =Rin . (0) /Rin . (t) ] were too opaque to identify the inner surface of the liner with high confidence, demonstrating the need for a higher-energy x-ray backlighter between 6 and 10 keV. We present the design, test and first application of a Ge (335) spherical crystal x-ray backlighter system using the 7.242 keV Co Heα resonance line. The system operates at an almost identical Bragg angle as the existing 1.865 and 6.151 keV backlighters, enhancing our capabilities such as two-color, two-frame radiography, without changing detector shielding hardware. SAND No: SAND2016-6724 A. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corp., a wholly owned subsidiary of Lockheed Martin Corp., for the U.S. DoE NNSA under contract DE-AC04-94AL85000.

  7. Recent laser upgrades at Sandia’s Z-backlighter facility in order to accommodate new requirements for magnetized liner inertial fusion on the Z-machine

    DOE PAGES

    Schwarz, Jens; Rambo, Patrick; Armstrong, Darrell; ...

    2016-10-21

    The Z-backlighter laser facility primarily consists of two high energy, high-power laser systems. Z-Beamlet laser (ZBL) (Rambo et al., Appl. Opt. 44, 2421 (2005)) is a multi-kJ-class, nanosecond laser operating at 1054 nm which is frequency doubled to 527 nm in order to provide x-ray backlighting of high energy density events on the Z-machine. Z-Petawatt (ZPW) (Schwarz et al., J. Phys.: Conf. Ser. 112, 032020 (2008)) is a petawatt-class system operating at 1054 nm delivering up to 500 J in 500 fs for backlighting and various short-pulse laser experiments (see also Figure 10 for a facility overview). With the developmentmore » of the magnetized liner inertial fusion (MagLIF) concept on the Z-machine, the primary backlighting missions of ZBL and ZPW have been adjusted accordingly. As a result, we have focused our recent efforts on increasing the output energy of ZBL from 2 to 4 kJ at 527 nm by modifying the fiber front end to now include extra bandwidth (for stimulated Brillouin scattering suppression). The MagLIF concept requires a well-defined/behaved beam for interaction with the pressurized fuel. Hence we have made great efforts to implement an adaptive optics system on ZBL and have explored the use of phase plates. We are also exploring concepts to use ZPW as a backlighter for ZBL driven MagLIF experiments. Alternatively, ZPW could be used as an additional fusion fuel pre-heater or as a temporally flexible high energy pre-pulse. All of these concepts require the ability to operate the ZPW in a nanosecond long-pulse mode, in which the beam can co-propagate with ZBL. Finally, some of the proposed modifications are complete and most of them are well on their way.« less

  8. Recent laser upgrades at Sandia’s Z-backlighter facility in order to accommodate new requirements for magnetized liner inertial fusion on the Z-machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarz, Jens; Rambo, Patrick; Armstrong, Darrell

    The Z-backlighter laser facility primarily consists of two high energy, high-power laser systems. Z-Beamlet laser (ZBL) (Rambo et al., Appl. Opt. 44, 2421 (2005)) is a multi-kJ-class, nanosecond laser operating at 1054 nm which is frequency doubled to 527 nm in order to provide x-ray backlighting of high energy density events on the Z-machine. Z-Petawatt (ZPW) (Schwarz et al., J. Phys.: Conf. Ser. 112, 032020 (2008)) is a petawatt-class system operating at 1054 nm delivering up to 500 J in 500 fs for backlighting and various short-pulse laser experiments (see also Figure 10 for a facility overview). With the developmentmore » of the magnetized liner inertial fusion (MagLIF) concept on the Z-machine, the primary backlighting missions of ZBL and ZPW have been adjusted accordingly. As a result, we have focused our recent efforts on increasing the output energy of ZBL from 2 to 4 kJ at 527 nm by modifying the fiber front end to now include extra bandwidth (for stimulated Brillouin scattering suppression). The MagLIF concept requires a well-defined/behaved beam for interaction with the pressurized fuel. Hence we have made great efforts to implement an adaptive optics system on ZBL and have explored the use of phase plates. We are also exploring concepts to use ZPW as a backlighter for ZBL driven MagLIF experiments. Alternatively, ZPW could be used as an additional fusion fuel pre-heater or as a temporally flexible high energy pre-pulse. All of these concepts require the ability to operate the ZPW in a nanosecond long-pulse mode, in which the beam can co-propagate with ZBL. Finally, some of the proposed modifications are complete and most of them are well on their way.« less

  9. A broadband proton backlighting platform to probe shock propagation in low-density systems

    DOE PAGES

    Sio, H.; Hua, R.; Ping, Y.; ...

    2017-01-17

    A proton backlighting platform has been developed for the study of strong shock propagation in low-density systems in planar geometry. Electric fields at the converging shock front in inertial confinement fusion implosions have been previously observed, demonstrating the presence of—and the need to understand—strong electric fields not modeled in standard radiation-hydrodynamic simulations. In this planar configuration, long-pulse ultraviolet lasers are used to drive a strong shock into a gas-cell target, while a short-pulse proton backlighter side-on radiographs the shock propagation. Finally, the capabilities of the platform are presented here. Future experiments will vary shock strength and gas fill, to probemore » shock conditions at different Z and T e.« less

  10. A multi-directional backlight for a wide-angle, glasses-free three-dimensional display.

    PubMed

    Fattal, David; Peng, Zhen; Tran, Tho; Vo, Sonny; Fiorentino, Marco; Brug, Jim; Beausoleil, Raymond G

    2013-03-21

    Multiview three-dimensional (3D) displays can project the correct perspectives of a 3D image in many spatial directions simultaneously. They provide a 3D stereoscopic experience to many viewers at the same time with full motion parallax and do not require special glasses or eye tracking. None of the leading multiview 3D solutions is particularly well suited to mobile devices (watches, mobile phones or tablets), which require the combination of a thin, portable form factor, a high spatial resolution and a wide full-parallax view zone (for short viewing distance from potentially steep angles). Here we introduce a multi-directional diffractive backlight technology that permits the rendering of high-resolution, full-parallax 3D images in a very wide view zone (up to 180 degrees in principle) at an observation distance of up to a metre. The key to our design is a guided-wave illumination technique based on light-emitting diodes that produces wide-angle multiview images in colour from a thin planar transparent lightguide. Pixels associated with different views or colours are spatially multiplexed and can be independently addressed and modulated at video rate using an external shutter plane. To illustrate the capabilities of this technology, we use simple ink masks or a high-resolution commercial liquid-crystal display unit to demonstrate passive and active (30 frames per second) modulation of a 64-view backlight, producing 3D images with a spatial resolution of 88 pixels per inch and full-motion parallax in an unprecedented view zone of 90 degrees. We also present several transparent hand-held prototypes showing animated sequences of up to six different 200-view images at a resolution of 127 pixels per inch.

  11. Recent advances in the science and technology for solid state lighting

    NASA Astrophysics Data System (ADS)

    Munkholm, Anneli

    2003-03-01

    Recent development of high power light emitting diodes (LEDs) has enabled fabrication of solid state devices with efficiencies that surpass that of incandescent light, as well as providing a total light output significantly exceeding that of conventional indicator LEDs. This breakthrough in high flux is opening up new applications for use of high power LEDs, such as liquid crystal display backlighting and automotive headlights. Some of the key elements to this technological breakthrough are the flip-chip device design, power packaging and phosphor coating technology, which will be discussed. In addition to device design improvements, our fundamental knowledge of the III-nitride material system is improving and has resulted in higher internal quantum efficiencies. Strain plays a significant role in complex AlInGaN heterostructures used in current devices. Using a multi-beam optical strain sensor (MOSS) system to measure the wafer curvature in situ, we have characterized the strain during metal-organic chemical vapor deposition of III-nitrides. Strain measurements of InGaN, AlGaN and Si-doped GaN films on GaN will be presented.

  12. A study of optical design of backlight module with external illuminance

    NASA Astrophysics Data System (ADS)

    Yen, Chih-Ta; Fang, Yi-Chin

    2011-10-01

    This research proposes the concept of Light Guide Film (LGF) at the back side of Back Light Unit (BLU). This new design may induce the exterior light, and then improve the power-saving of existent BLU. Two design models are reseated: One is design for 14 inch LCD monitor of notebook computer, which might improve 21% compared to traditional one. Another is designed for 3.5 inch LCD for mobile phone display, which might improve 15% compared to traditional one.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoeckl, C., E-mail: csto@lle.rochester.edu; Bedzyk, M.; Brent, G.

    A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si He{sub α} line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable ofmore » moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 μm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.« less

  14. X-ray imaging of fibers

    NASA Astrophysics Data System (ADS)

    Moosman, B.; Song, Y.; Weathers, L.; Wessel, F.

    1996-11-01

    A pulsed x-ray backlighter was developed to image exploding wires and cryogenic fibers. The x-ray pulse width is between 10-20 ns, with an output of 100-150 mJ, mostly in the Al k-shell (1.486 keV). The backlighter is located 50 cm from the 20-50 micron diameter target (typically, a copper wire). A 15 micron Al filter eliminates UV emission from the backlighter and target. It is placed 3 cm from the target with SB-5 film directly behind it. From the optical density of the film, target absorption and density can be calculated. The spatial resolution of this system is better than 40 microns. The wire is exploded using a 10 kA, 1 microsecond pulser. Analysis with simultaneous Moire imaging will also be presented. Supported by Los Alamos National Laboratories

  15. Single line-of-sight dual energy backlighter for mix width experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, K. L., E-mail: baker7@llnl.gov; Glendinning, S. G.; Martinez, D.

    2014-11-15

    We present a diagnostic technique used to spatially multiplex two x-ray radiographs of an object onto a detector along a single line-of-sight. This technique uses a thin, <2 μm, cosputtered backlighter target to simultaneously produce both Ni and Zn He{sub α} emission. A Ni picket fence filter, 500 μm wide bars and troughs, is then placed in front of the detector to pass only the Ni He{sub α} emission in the bar region and both energies in the trough region thereby spatially multiplexing the two radiographs on a single image. Initial experimental results testing the backlighter spectrum are presented alongmore » with simulated images showing the calculated radiographic images though the nickel picket fence filter which are used to measure the mix width in an accelerated nickel foam.« less

  16. Heat resistive dielectric multi-layer micro-mirror array in epitaxial lateral overgrowth gallium nitride.

    PubMed

    Huang, Chen-Yang; Ku, Hao-Min; Liao, Wei-Tsai; Chao, Chu-Li; Tsay, Jenq-Dar; Chao, Shiuh

    2009-03-30

    Ta2O5 / SiO2 dielectric multi-layer micro-mirror array (MMA) with 3mm mirror size and 6mm array period was fabricated on c-plane sapphire substrate. The MMA was subjected to 1200 degrees C high temperature annealing and remained intact with high reflectance in contrast to the continuous multi-layer for which the layers have undergone severe damage by 1200 degrees C annealing. Epitaxial lateral overgrowth (ELO) of gallium nitride (GaN) was applied to the MMA that was deposited on both sapphire and sapphire with 2:56 mm GaN template. The MMA was fully embedded in the ELO GaN and remained intact. The result implies that our MMA is compatible to the high temperature growth environment of GaN and the MMA could be incorporated into the structure of the micro-LED array as a one to one micro backlight reflector, or as the patterned structure on the large area LED for controlling the output light.

  17. The Crystal Backlighter Imager: a spherically-bent crystal imager for radiography on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Hall, Gareth; Krauland, Christine; Buscho, Justin; Hibbard, Robin; McCarville, Thomas; Lowe-Webb, Roger; Ayers, Shannon; Kalantar, Daniel; Kohut, Thomas; Kemp, G. Elijah; Bradley, David; Bell, Perry; Landen, Otto; Brewster, Nathaniel; Piston, Kenneth

    2017-10-01

    The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically-bent crystal imager being developed for the NIF, which will allow ICF capsule implosions to be radiographed close to stagnation for the first time. This has not been possible using the previous pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter in the final stages of the implosion. CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth (a few eV) inherent to imagers based on near-normal-incidence Bragg x-ray optics. The development of a diagnostic with the capability to image the capsule during the final stages of the implosion (r less than 200um) is important, as it will allow the shape, integrity and density of the shell to be measured, and will allow the evolution of features, such as the fill tube and capsule support structure, to be imaged close to bang time. The concept and operation of the 11.6keV CBI diagnostic will be discussed, and the first results from experiments on the NIF will be presented. Prepared by LLNL under Contract DE-AC52-07NA27344.

  18. Prospects of III-nitride optoelectronics grown on Si.

    PubMed

    Zhu, D; Wallis, D J; Humphreys, C J

    2013-10-01

    The use of III-nitride-based light-emitting diodes (LEDs) is now widespread in applications such as indicator lamps, display panels, backlighting for liquid-crystal display TVs and computer screens, traffic lights, etc. To meet the huge market demand and lower the manufacturing cost, the LED industry is moving fast from 2 inch to 4 inch and recently to 6 inch wafer sizes. Although Al2O3 (sapphire) and SiC remain the dominant substrate materials for the epitaxy of nitride LEDs, the use of large Si substrates attracts great interest because Si wafers are readily available in large diameters at low cost. In addition, such wafers are compatible with existing processing lines for 6 inch and larger wafers commonly used in the electronics industry. During the last decade, much exciting progress has been achieved in improving the performance of GaN-on-Si devices. In this contribution, the status and prospects of III-nitride optoelectronics grown on Si substrates are reviewed. The issues involved in the growth of GaN-based LED structures on Si and possible solutions are outlined, together with a brief introduction to some novel in situ and ex situ monitoring/characterization tools, which are especially useful for the growth of GaN-on-Si structures.

  19. Measurement of inflight shell areal density perturbations in NIF capsule implosions near peak velocity

    NASA Astrophysics Data System (ADS)

    Hammel, B. A.; Pickworth, L.; Smalyuk, V.; Macphee, A.; Scott, H. A.; Robey, H.; Barrios, M.; Regan, S. P.

    2015-11-01

    Quantitative measurements of shell-RhoR perturbations in capsules near peak implosion velocity (PV) are challenging. An external backlighter samples both sides of the shell, unless a re-entrant cone is used (potentially perturbing implosion). Emission from the hot core, after shock-stagnation and prior to PV, has been used as a self-backlighter, providing a means to sample one side of the capsule. Adding high-Z gas (~ 1% Ar) to the capsule fill in Symcaps (4He), has produced a continuum backlighter with significant increase in emission at photon energies ~ 8 keV over nominal fills. From images of the transmitted self-emission, above and below the K-edge of an internally doped Cu layer, we infer the growth at PV of imposed perturbations (100 nm amplitude, mode 40). Prepared by LLNL under Contract DE-AC52-07NA27344.

  20. Highly luminescent and photostable quantum dot-silica monolith and its application to light-emitting diodes.

    PubMed

    Jun, Shinae; Lee, Junho; Jang, Eunjoo

    2013-02-26

    A highly luminescent and photostable quantum dot-silica monolith (QD-SM) substance was prepared by preliminary surface exchange of the QDs and base-catalyzed sol-gel condensation of silica. The SM was heavily doped with 6-mercaptohexanol exchanged QDs up to 12 vol % (26 wt %) without particle aggregation. Propylamine catalyst was important in maintaining the original luminescence of the QDs in the SM during sol-gel condensation. The silica layer was a good barrier against oxygen and moisture, so that the QD-SM maintained its initial luminescence after high-power UV radiation (∼1 W) for 200 h and through the 150 °C LED encapsulant curing process. Green and red light-emitting QD-SMs were applied as color-converting layers on blue LEDs, and the external quantum efficiency reached up to 89% for the green QD-SM and 63% for the red one. A white LED made with a mixture of green and red QDs in the SM, in which the color coordinate was adjusted at (0.23, 0.21) in CIE1931 color space for a backlight application, showed an efficacy of 47 lm/W, the highest value yet reported.

  1. The Laser-Driven X-ray Big Area Backlighter (BABL): Design, Optimization, and Evolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flippo, Kirk Adler; DeVolder, Barbara Gloria; Doss, Forrest William

    The Big Area BackLigher (BABL) has been developed for large area laser-driven x-ray backlighting on the National Ignition Facility (NIF), which can be used for general High Energy Density (HED) experiments. The BABL has been optimized via hydrodynamic simulations to produce laser-to-x-ray conversion efficiencies of up to nearly 5%. Lastly, four BABL foil materials, Zn, Fe, V, and Cu, have been used for He-α x ray production.

  2. Interpretation of digital chest radiographs: comparison of light emitting diode versus cold cathode fluorescent lamp backlit monitors.

    PubMed

    Lim, Hyun-ju; Chung, Myung Jin; Lee, Geewon; Yie, Miyeon; Shin, Kyung Eun; Moon, Jung Won; Lee, Kyung Soo

    2013-01-01

    To compare the diagnostic performance of light emitting diode (LED) backlight monitors and cold cathode fluorescent lamp (CCFL) monitors for the interpretation of digital chest radiographs. We selected 130 chest radiographs from health screening patients. The soft copy image data were randomly sorted and displayed on a 3.5 M LED (2560 × 1440 pixels) monitor and a 3 M CCFL (2048 × 1536 pixels) monitor. Eight radiologists rated their confidence in detecting nodules and abnormal interstitial lung markings (ILD). Low dose chest CT images were used as a reference standard. The performance of the monitor systems was assessed by analyzing 2080 observations and comparing them by multi-reader, multi-case receiver operating characteristic analysis. The observers reported visual fatigue and a sense of heat. Radiant heat and brightness of the monitors were measured. Measured brightness was 291 cd/m(2) for the LED and 354 cd/m(2) for the CCFL monitor. Area under curves for nodule detection were 0.721 ± 0.072 and 0.764 ± 0.098 for LED and CCFL (p = 0.173), whereas those for ILD were 0.871 ± 0.073 and 0.844 ± 0.068 (p = 0.145), respectively. There were no significant differences in interpretation time (p = 0.446) or fatigue score (p = 0.102) between the two monitors. Sense of heat was lower for the LED monitor (p = 0.024). The temperature elevation was 6.7℃ for LED and 12.4℃ for the CCFL monitor. Although the LED monitor had lower maximum brightness compared with the CCFL monitor, soft copy reading of the digital chest radiographs on LED and CCFL showed no difference in terms of diagnostic performance. In addition, LED emitted less heat.

  3. Backlighting Direct-Drive Cryogenic DT Implosions on OMEGA

    NASA Astrophysics Data System (ADS)

    Stoeckl, C.

    2016-10-01

    X-ray backlighting has been frequently used to measure the in-flight characteristics of an imploding shell in both direct- and indirect-drive inertial confinement fusion implosions. These measurements provide unique insight into the early time and stagnation stages of an implosion and guide the modeling efforts to improve the target designs. Backlighting a layered DT implosion on OMEGA is a particular challenge because the opacity of the DT shell is low, the shell velocity is high, the size and wall thickness of the shell is small, and the self-emission from the hot core at the onset of burn is exceedingly bright. A framing-camera-based crystal imaging system with a Si Heα backlighter at 1.865keV driven by 10-ps short pulses from OMEGA EP was developed to meet these radiography challenges. A fast target inserter was developed to accurately place the Si backlighter foil at a distance of 5 mm to the implosion target following the removal of the cryogenic shroud and an ultra-stable triggering system was implemented to reliably trigger the framing camera coincident with the arrival of the OMEGA EP pulse. This talk will report on a series of implosions in which the DT shell is imaged for a range of convergence ratios and in-flight aspect ratios. The images acquired have been analyzed for low-mode shape variations, the DT shell thickness, the level of ablator mixing into the DT fuel (even 0.1% of carbon mix can be reliably inferred), the areal density of the DT shell, and the impact of the support stalk. The measured implosion performance will be compared with hydrodynamic simulations that include imprint (up to mode 200), cross-beam energy transfer, nonlocal thermal transport, and initial low-mode perturbations such as power imbalance and target misalignment. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  4. Illumination design for semiconductor backlight inspection and application extensions

    NASA Astrophysics Data System (ADS)

    Zhou, Wei; Rutherford, Todd; Hart, Darcy

    2013-09-01

    High speed strobe based illumination scheme is one of the most critical factors for high throughput semiconductor defect inspection applications. HB LEDs are always the first and best options for such applications due to numerous unique advantages such as excellent spatial and temporal stability, fast responding time, large and linear intensity dynamic range and no heat issue for the extremely low duty cycle applications. For some applications where a large area is required to be illuminated simultaneously, it remains a great challenge to efficiently package a large amount of HB-LEDs in a highly confined 3D space, to generate a seamless illuminated area with high luminance efficiency and spatial uniformity. A novel 3D structured collimation lens is presented in this paper. The non-circular edge shape reduces the intensity drop at the channel boundaries, while the secondary curvatures on the top of the collimator lens efficiently guides the light into desired angular space. The number of the edges and the radius of the top surface curvature are control parameters for the system level performance and the manufacture cost trade-off. The proposed 3D structured LED collimation lens also maintains the benefits of traditional LED collimation lens such as coupling efficiency and mold manufacture capability. The applications can be extended into other non-illumination area like parallelism measurement and solar panel concentrator etc.

  5. High-efficiency directional backlight design for an automotive display.

    PubMed

    Chen, Bo-Tsuen; Pan, Jui-Wen

    2018-06-01

    We propose a high-efficiency directional backlight module (DBM) for automotive display applications. The DBM is composed of light sources, a light guide plate (LGP), and an optically patterned plate (OPP). The LGP has a collimator on the input surface that serves to control the angle of the light emitted to be in the horizontal direction. The OPP has an inverse prism to adjust the light emission angle in the vertical direction. The DBM has a simple structure and high optical efficiency. Compared with conventional backlight systems, the DBM has higher optical efficiency and a suitable viewing angle. This is an improvement in normalized on-axis luminous intensity of 2.6 times and a twofold improvement in optical efficiency. The viewing angles are 100° in the horizontal direction and 35° in the vertical direction. The angle of the half-luminous intensity is 72° in the horizontal direction and 20° in the vertical direction. The uniformity of the illuminance reaches 82%. The DBM is suitable for use in the center information displays of automobiles.

  6. Review of the evolution of display technologies for next-generation aircraft

    NASA Astrophysics Data System (ADS)

    Tchon, Joseph L.; Barnidge, Tracy J.

    2015-05-01

    Advancements in electronic display technologies have provided many benefits for military avionics. The modernization of legacy tanker transport aircraft along with the development of next-generation platforms, such as the KC-46 aerial refueling tanker, offers a timeline of the evolution of avionics display approaches. The adaptation of advanced flight displays from the Boeing 787 for the KC-46 flight deck also provides examples of how avionics display solutions may be leveraged across commercial and military flight decks to realize greater situational awareness and improve overall mission effectiveness. This paper provides a review of the display technology advancements that have led to today's advanced avionics displays for the next-generation KC-46 tanker aircraft. In particular, progress in display operating modes, backlighting, packaging, and ruggedization will be discussed along with display certification considerations across military and civilian platforms.

  7. LLE review. Quarterly report, January 1994--March 1994, Volume 58

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, A.

    1994-07-01

    This volume of the LLE Review, covering the period Jan - Mar 1994, contains articles on backlighting diagnostics; the effect of electron collisions on ion-acoustic waves and heat flow; using PIC code simulations for analysis of ultrashort laser pulses interacting with solid targets; creating a new instrument for characterizing thick cryogenic layers; and a description of a large-aperture ring amplifier for laser-fusion drivers. Three of these articles - backlighting diagnostics; characterizing thick cryogenic layers; and large-aperture ring amplifier - are directly related to the OMEGA Upgrade, now under construction. Separate abstracts have been prepared for articles from this report.

  8. Color enhancement for portable LCD displays in low-power mode

    NASA Astrophysics Data System (ADS)

    Shih, Kuang-Tsu; Huang, Tai-Hsiang; Chen, Homer H.

    2011-09-01

    Switching the backlight of handheld devices to low power mode saves energy but affects the color appearance of an image. In this paper, we consider the chroma degradation problem and propose an enhancement algorithm that incorporates the CIECAM02 appearance model to quantitatively characterize the problem. In the proposed algorithm, we enhance the color appearance of the image in low power mode by weighted linear superposition of the chroma of the image and that of the estimated dim-backlight image. Subjective tests are carried out to determine the perceptually optimal weighting and prove the effectiveness of our framework.

  9. Machine learning techniques for energy optimization in mobile embedded systems

    NASA Astrophysics Data System (ADS)

    Donohoo, Brad Kyoshi

    Mobile smartphones and other portable battery operated embedded systems (PDAs, tablets) are pervasive computing devices that have emerged in recent years as essential instruments for communication, business, and social interactions. While performance, capabilities, and design are all important considerations when purchasing a mobile device, a long battery lifetime is one of the most desirable attributes. Battery technology and capacity has improved over the years, but it still cannot keep pace with the power consumption demands of today's mobile devices. This key limiter has led to a strong research emphasis on extending battery lifetime by minimizing energy consumption, primarily using software optimizations. This thesis presents two strategies that attempt to optimize mobile device energy consumption with negligible impact on user perception and quality of service (QoS). The first strategy proposes an application and user interaction aware middleware framework that takes advantage of user idle time between interaction events of the foreground application to optimize CPU and screen backlight energy consumption. The framework dynamically classifies mobile device applications based on their received interaction patterns, then invokes a number of different power management algorithms to adjust processor frequency and screen backlight levels accordingly. The second strategy proposes the usage of machine learning techniques to learn a user's mobile device usage pattern pertaining to spatiotemporal and device contexts, and then predict energy-optimal data and location interface configurations. By learning where and when a mobile device user uses certain power-hungry interfaces (3G, WiFi, and GPS), the techniques, which include variants of linear discriminant analysis, linear logistic regression, non-linear logistic regression, and k-nearest neighbor, are able to dynamically turn off unnecessary interfaces at runtime in order to save energy.

  10. Employing the conventional edge-lighting technology into ultraviolet-range: a preliminary study by optical simulation

    NASA Astrophysics Data System (ADS)

    Ye, Linchao; Belloni, Paola; Möller, Knut

    2011-10-01

    Within the framework of a project conducted together with an industrial partner, a self-disinfecting operation interface with a glass panel is being developed. The concept of self-disinfection is based on the exploitation of the photocatalytical effect induced by a TiO2-coating on the glass surface under UV(A) light, which would make the touch screen antimicrobial. High-power UV-LEDs instead of conventional UV-lamps have been employed as light source. The main goal and challenge of the optical design is to generate an efficient and preferably homogeneous UV field on the TiO2-coated side while keeping the UV-LEDs concealed, i.e. invisible to the user. Therefore common backlighting systems have been used as reference and modified to meet the concrete requirements. Primary analysis and optical simulations have been performed with the software LightTools®. Several patterns for light redirection (i.e. 3D-spherical texture, 3D-rectangular texture and 2D-circular serigraph) have been investigated, compared and evaluated. Finally the pattern design which both fulfills all the predefined boundary conditions and simultaneously reduces the costs has been chosen.

  11. Microscopic video observation of capillary vessel systems using diffuse back lighting

    NASA Astrophysics Data System (ADS)

    Sakai, Minako; Arai, Hiroki; Iwai, Toshiaki

    2017-04-01

    We have been developing a simple and practical video microscopy system based on absorption spectra of biological substance to perform spectroscopic observation of living tissues. The diffuse backlighting effect is actively used in the developed system, which is generated by multiple light scattering in the tissue. It is demonstrated that the light specularly reflected from the skin surface can be completely suppressed in the microscopic observation and the biological activity of the capillary vessel systems distributed under the skin can be successfully observed. As a result, we can confirm the effectiveness of the video microscopy system using diffuse backlighting and the applicability of our developed system.

  12. Novel photonics polymer and its application in IT

    NASA Astrophysics Data System (ADS)

    Koike, Yasuhiro

    2003-07-01

    In the field of LANs, transmission systems based on a multimode silica fiber network is heading towards capacities of Gb/s. We have proposed a low-loss, high-bandwidth and large-core graded-index plastic optical fiber (GI POF) in data-com. area. We sill show that GI POF enables to virtually eliminate the "modal noise" problem cased by the medium-core silica fibers. Therefore, stable high-speed data transmission is realized by GI POF rather than silica fibers. Furthermore, advent of perfluorinated (PF) polymer based GI POF network can support higher transmission than silica fibers network because of the small material dispersion of PF polymer compared with silica. In addition, we proposed a "highly scattering optical transmission (HSOT) polymer" and applied it to a light guide plate of a liquid crystal display (LCD) backlight. The advanced HSOT polymer backlight that was proposed using the HSOT designing simulation program demonstrated approximately three times higher luminance than the conventional flat-type HSOT backlight of 14.1-inch diagonal because of the microscopic prism structures at the bottom of the advanced HSOT light guide plate. The HSOT polymer containing the optimized heterogeneous structures produced homogeneous scattered light with forward directivity and sufficient color uniformity.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schollmeier, Marius S.; Geissel, Matthias; Shores, Jonathon E.

    We present calculations for the field of view (FOV), image fluence, image monochromaticity, spectral acceptance, and image aberrations for spherical crystal microscopes, which are used as self-emission imaging or backlighter systems at large-scale high energy density physics facilities. Our analytic results are benchmarked with ray-tracing calculations as well as with experimental measurements from the 6.151 keV backlighter system at Sandia National Laboratories. Furthermore, the analytic expressions can be used for x-ray source positions anywhere between the Rowland circle and object plane. We discovered that this enables quick optimization of the performance of proposed but untested, bent-crystal microscope systems to findmore » the best compromise between FOV, image fluence, and spatial resolution for a particular application.« less

  14. A direct-drive exploding-pusher implosion as the first step in development of a monoenergetic charged-particle backlighting platforn at the National Ignition Facility

    DOE PAGES

    Rosenberg, M. J.; Zylstra, A. B.; Seguin, F. H.; ...

    2016-01-18

    A thin-glass-shell, D 3He-filled exploding-pusher inertial confinement fusion implosion at the National Ignition Facility (NIF) has been demonstrated as a proton source that serves as a promising first step toward development of a monoenergetic proton, alpha, and triton backlighting platform at the NIF. Among the key measurements, the D3He-proton emission on this experiment (shot N121128) has been well-characterized spectrally, temporally, and in terms of emission isotropy, revealing a highly monoenergetic (ΔE/E~4%) and isotropic source (~3% proton fluence variation and ~0.5% proton energy variation). On a similar shot (N130129, with D 2 fill), the DD-proton spectrum has been obtained as well,more » illustrating that monoenergetic protons of multiple energies may be utilized in a single experiment. In conclusion, these results, and experiments on OMEGA, point toward future steps in the development of a precision, monoenergetic proton, alpha, and triton source that can readily be implemented at the NIF for backlighting a broad range of high energy density physics (HEDP) experiments in which fields and flows are manifest, and also utilized for studies of stopping power in warm dense matter and in classical plasmas.« less

  15. A direct-drive exploding-pusher implosion as the first step in development of a monoenergetic charged-particle backlighting platforn at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, M. J.; Zylstra, A. B.; Seguin, F. H.

    A thin-glass-shell, D 3He-filled exploding-pusher inertial confinement fusion implosion at the National Ignition Facility (NIF) has been demonstrated as a proton source that serves as a promising first step toward development of a monoenergetic proton, alpha, and triton backlighting platform at the NIF. Among the key measurements, the D3He-proton emission on this experiment (shot N121128) has been well-characterized spectrally, temporally, and in terms of emission isotropy, revealing a highly monoenergetic (ΔE/E~4%) and isotropic source (~3% proton fluence variation and ~0.5% proton energy variation). On a similar shot (N130129, with D 2 fill), the DD-proton spectrum has been obtained as well,more » illustrating that monoenergetic protons of multiple energies may be utilized in a single experiment. In conclusion, these results, and experiments on OMEGA, point toward future steps in the development of a precision, monoenergetic proton, alpha, and triton source that can readily be implemented at the NIF for backlighting a broad range of high energy density physics (HEDP) experiments in which fields and flows are manifest, and also utilized for studies of stopping power in warm dense matter and in classical plasmas.« less

  16. Development of a short duration backlit pinhole for radiography on the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huntington, C. M.; Krauland, C. M.; Kuranz, C. C.

    2010-10-15

    Experiments on the National Ignition Facility (NIF) will require bright, short duration, near-monochromatic x-ray backlighters for radiographic diagnosis of many high-energy density systems. This paper details a vanadium pinhole backlighter producing (1.8{+-}0.5)x10{sup 15} x-ray photons into 4{pi} sr near the vanadium He-like characteristic x-ray energy of 5.18 keV. The x-ray yield was quantified from a set of Ross filters imaged to a calibrated image plate, with the Dante diagnostic used to confirm the quasimonochromatic nature of the spectrum produced. Additionally, an x-ray film image shows a source-limited image resolution of 26 {mu}m from a 20 {mu}m diameter pinhole.

  17. FSC LCD technology for military and avionics applications

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri R.; Schmidt, John; Roush, Jerry

    2009-05-01

    Field sequential color (FSC) liquid crystal displays (LCD) using a high speed LCD mode and an R, G, B LED backlight, offers a significant potential for lower power consumption, higher resolution, higher brightness and lower cost compared to the conventional R, G, B color filter based LCD, and thus is of interest to various military and avionic display applications. While the DLP projection TVs, and Camcorder LCD view finder type displays using the FSC technology have been introduced in the consumer market, large area direct view LCD displays based on the FSC technology have not reached the commercial market yet. Further, large area FSC LCDs can present unique operational issues in avionic and military environments particularly for operation in a broad temperature range and with respect to its susceptibility for the color breakup image artifact. In this paper we will review the current status of the FSC LCD technology and then discuss the results of our efforts on the FSC LCD technology evaluation for the avionic applications.

  18. 'No power' (green) electrowetting display

    NASA Astrophysics Data System (ADS)

    Jentsch, Michael; Rawert, Juergen; Jerosch, Dieter; Blankenbach, Karlheinz

    2011-05-01

    Electrowetting displays were first reported in 1981, several approaches were examined. However, ADT's "Droplet- Driven-Displays" technology is the only bistable one which makes them very attractive for energy-saving systems. That means that the power supply can completely shut off after changing the content and it will keep its information for years. More features that make the ADT approach very unique are paper like white appearance (even in the powerless OFFstate) and the capability for backlighting (most of the other e-paper technologies like electrophoretics can not be backlighted). Further achievements are a white state reflectance of about 70% resulting in sunlight readability and a pixel size in the range from 0.3mm to 10mm. Summarizing, ADT's electrowetting technology is highly suitable for lowest power (means eco-friendly or "green") displays.

  19. Comparisons of NIF convergent ablation simulations with radiograph data.

    PubMed

    Olson, R E; Hicks, D G; Meezan, N B; Koch, J A; Landen, O L

    2012-10-01

    A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.

  20. Omni-Directional Viewing-Angle Switching through Control of the Beam Divergence Angle in a Liquid Crystal Panel

    NASA Astrophysics Data System (ADS)

    Baek, Jong-In; Kim, Ki-Han; Kim, Jae Chang; Yoon, Tae-Hoon

    2010-01-01

    This paper proposes a method of omni-directional viewing-angle switching by controlling the beam diverging angle (BDA) in a liquid crystal (LC) panel. The LCs aligned randomly by in-cell polymer structures diffuse the collimated backlight for the bright state of the wide viewing-angle mode. We align the LCs homogeneously by applying an in-plane field for the narrow viewing-angle mode. By doing this the scattering is significantly reduced so that the small BDA is maintained as it passes through the LC layer. The dark state can be obtained by aligning the LCs homeotropically with a vertical electric field. We demonstrated experimentally the omni-directional switching of the viewing-angle, without an additional panel or backlighting system.

  1. Performance of bent-crystal x-ray microscopes for high energy density physics research

    DOE PAGES

    Schollmeier, Marius S.; Geissel, Matthias; Shores, Jonathon E.; ...

    2015-05-29

    We present calculations for the field of view (FOV), image fluence, image monochromaticity, spectral acceptance, and image aberrations for spherical crystal microscopes, which are used as self-emission imaging or backlighter systems at large-scale high energy density physics facilities. Our analytic results are benchmarked with ray-tracing calculations as well as with experimental measurements from the 6.151 keV backlighter system at Sandia National Laboratories. Furthermore, the analytic expressions can be used for x-ray source positions anywhere between the Rowland circle and object plane. We discovered that this enables quick optimization of the performance of proposed but untested, bent-crystal microscope systems to findmore » the best compromise between FOV, image fluence, and spatial resolution for a particular application.« less

  2. New cryogenic temperature monitor: PLT-HPT-32

    NASA Astrophysics Data System (ADS)

    Viera Curbelo, Teodora Aleida; Martín-Fernández, Sergio Gonzáles; Hoyland, R.; Vega-Moreno, A.; Cozar Castellano, Juan; Gómez Reñasco, M. F.; Aguiar-González, M.; Pérez de Taoro, Angeles; Sánchez-de la Rosa, V.; Rubiño-Martín, J. A.; Génova-Santos, R.

    2016-07-01

    The PLT-HPT-32, a new cryogenic temperature monitor, has been developed by the Institute of Astrophysics of the Canary Islands (IAC) and an external engineering company (Sergio González Martín-Fernandez). The PLT-HPT-32 temperature monitor offers precision measurement in a wide range of cryogenic and higher-temperature applications with the ability to easily monitor up to 32 sensor channels. It provides better measurement performance in applications where researchers need to ensure accuracy and precision in their low cryogenic temperature monitoring. The PLT-HPT-32 supports PTC RTDs such as platinum sensors, and diodes such as the Lake Shore DT-670 Series. Used with silicon diodes, it provides accurate measurements in cryo-cooler applications from 16 K to above room temperature. The resolution of the measurement is less than 0.1K. Measurements can be displayed in voltage units or Kelvin units. For it, two different tables can be used. One can be programmed by the user, and the other one corresponds to Lake Shore DT670 sensor that comes standard. There are two modes of measuring, the instantaneous mode and averaged mode. In this moment, all channels must work in the same mode but in the near future it expected to be used in blocks of eight channels. The instantaneous mode takes three seconds to read all channels. The averaged mode takes one minute to average twenty samples in all channels. Alarm thresholds can be configured independently for each input. The alarm events, come from the first eight channels, can activate the unit's relay outputs for hard-wired triggering of other systems or audible annunciators. Activate relays on high, low, or both alarms for any input. For local monitoring, "Stand-Alone Mode", the front panel of the PLT-HPT-32 features a bright liquid crystal display with an LED backlight that shows up to 32 readings simultaneously. Plus, monitoring can be done over a network "Remote Control Mode". Using the Ethernet port on the PLT-HPT-32, you can keep an eye on temperatures, log measurement and configured remotely via a Networked local PC or even remotely over a TCP/IP Internet connection from anywhere.

  3. Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Opachich, Y. P.; Heeter, R. F.; Barrios, M. A.; Garcia, E. M.; Craxton, R. S.; King, J. A.; Liedahl, D. A.; McKenty, P. W.; Schneider, M. B.; May, M. J.; Zhang, R.; Ross, P. W.; Kline, J. L.; Moore, A. S.; Weaver, J. L.; Flippo, K. A.; Perry, T. S.

    2017-06-01

    Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ˜20 μm thickness have been performed. X-ray yields of up to ˜1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ˜100 μm FWHM, with ˜350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

  4. Current progress and technical challenges of flexible liquid crystal displays

    NASA Astrophysics Data System (ADS)

    Fujikake, Hideo; Sato, Hiroto

    2009-02-01

    We focused on several technical approaches to flexible liquid crystal (LC) display in this report. We have been developing flexible displays using plastic film substrates based on polymer-dispersed LC technology with molecular alignment control. In our representative devices, molecular-aligned polymer walls keep plastic-substrate gap constant without LC alignment disorder, and aligned polymer networks create monostable switching of fast-response ferroelectric LC (FLC) for grayscale capability. In the fabrication process, a high-viscosity FLC/monomer solution was printed, sandwiched and pressed between plastic substrates. Then the polymer walls and networks were sequentially formed based on photo-polymerization-induced phase separation in the nematic phase by two exposure processes of patterned and uniform ultraviolet light. The two flexible backlight films of direct illumination and light-guide methods using small three-primary-color light-emitting diodes were fabricated to obtain high-visibility display images. The fabricated flexible FLC panels were driven by external transistor arrays, internal organic thin film transistor (TFT) arrays, and poly-Si TFT arrays. We achieved full-color moving-image displays using the flexible FLC panel and the flexible backlight film based on field-sequential-color driving technique. Otherwise, for backlight-free flexible LC displays, flexible reflective devices of twisted guest-host nematic LC and cholesteric LC were discussed with molecular-aligned polymer walls. Singlesubstrate device structure and fabrication method using self-standing polymer-stabilized nematic LC film and polymer ceiling layer were also proposed for obtaining LC devices with excellent flexibility.

  5. The performance of quantum dots-based white light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Chen, Kuan-Lin; Chung, Shu-Ru

    2017-08-01

    Recently, the investigation of quantum dots (QDs) as a color converter for white light-emitting diodes (WLEDs) application has attracted a great deal of attention. Because the narrow emission wavelength of QDs can be controlled by their particle sizes and compositions, which is facilitated to improve the color gamut of display as well as color rendering index (CRI) and the correlated color temperature (CCT) of WLEDs. In a typical commercially available LCD display, the color gamut is approximately to 75 % which is defined by the National Television System Committee (NTSC). In order to enhance NTSC, the full width at half-maximum (FWHM) of color converter should be less than 30 nm. Therefore, the QDs are the best choice for display application due to the FWHM of QDs is meet the demand of display application. In this study, the hot injection method with one-pot process is used to synthesis of colloidal ternary ZnCdSe green (G-) and red-emission (R-) QDs with a narrow emission wavelength around 537 and 610 nm. By controlling the complex reagents-stearic acid (SA) and lauric acid (LA), high performance of G- and R-QDs can be prepared. The quantum yields (QYs), particle sizes and FWHM for G- and R-QDs are 70, 30 %, 3.2 +/- 0.5, 4.1 +/- 0.5 nm and 25, 26 nm, respectively. In order to explore the performance of QDs-based WLEDs, mixing ratios effect between G-QD and R-QD are studied and the WLED is packed as conformal-type. Different ratios of R-QD and G-QD (1:10, 1:20 and 1:30) are mixed and fill up the 3020 SMD blue-InGaN LED, and named as LED-10, LED-20 and LED-30. After that, UV curable gel is deposited on the top of QD layer to form WLED and named as LED-10*, LED-20* and LED-30*. The results show that the Commission International d'Eclairage (CIE) chromaticity coordinates, color rendering index (CRI), luminous efficacy of LED-10*, LED-20* and LED-30* are (0.27, 0.21), 53, 1.9 lm/W, (0.29, 0.30), 72, 3.3 lm/W and (0.25, 0.34), 45, 6.8 lm/W, respectively. We can find that the positions of CIE can be controlled simply by adjusting the ratios of G- and R-QDs. Besides, the LED-10 and LED-20* device shows the high CRI, implying that it has great potential for application on backlight of display technology and solid-state lighting.

  6. X-ray absorption spectroscopy of aluminum z-pinch plasma with tungsten backlighter planar wire array source.

    PubMed

    Osborne, G C; Kantsyrev, V L; Safronova, A S; Esaulov, A A; Weller, M E; Shrestha, I; Shlyaptseva, V V; Ouart, N D

    2012-10-01

    Absorption features from K-shell aluminum z-pinch plasmas have recently been studied on Zebra, the 1.7 MA pulse power generator at the Nevada Terawatt Facility. In particular, tungsten plasma has been used as a semi-backlighter source in the generation of aluminum K-shell absorption spectra by placing a single Al wire at or near the end of a single planar W array. All spectroscopic experimental results were recorded using a time-integrated, spatially resolved convex potassium hydrogen phthalate (KAP) crystal spectrometer. Other diagnostics used to study these plasmas included x-ray detectors, optical imaging, laser shadowgraphy, and time-gated and time-integrated x-ray pinhole imagers. Through comparisons with previous publications, Al K-shell absorption lines are shown to be from much lower electron temperature (∼10-40 eV) plasmas than emission spectra (∼350-500 eV).

  7. Impact of different cleaning processes on the laser damage threshold of antireflection coatings for Z-Backlighter optics at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, Ella; Bellum, John; Kletecka, Damon

    We have examined how different cleaning processes affect the laser-induced damage threshold of antireflection coatings for large dimension, Z-Backlighter laser optics at Sandia National Laboratories. Laser damage thresholds were measured after the coatings were created, and again 4 months later to determine which cleaning processes were most effective. There is a nearly twofold increase in laser-induced damage threshold between the antireflection coatings that were cleaned and those that were not cleaned. Aging of the coatings after 4 months resulted in even higher laser-induced damage thresholds. Also, the laser-induced damage threshold results revealed that every antireflection coating had a high defectmore » density, despite the cleaning process used, which indicates that improvements to either the cleaning or deposition processes should provide even higher laser-induced damage thresholds.« less

  8. Error Budgeting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vinyard, Natalia Sergeevna; Perry, Theodore Sonne; Usov, Igor Olegovich

    2017-10-04

    We calculate opacity from k (hn)=-ln[T(hv)]/pL, where T(hv) is the transmission for photon energy hv, p is sample density, and L is path length through the sample. The density and path length are measured together by Rutherford backscatter. Δk =more » $$\\partial k$$\\ $$\\partial T$$ ΔT + $$\\partial k$$\\ $$\\partial (pL)$$. We can re-write this in terms of fractional error as Δk/k = Δ1n(T)/T + Δ(pL)/(pL). Transmission itself is calculated from T=(U-E)/(V-E)=B/B0, where B is transmitted backlighter (BL) signal and B 0 is unattenuated backlighter signal. Then ΔT/T=Δln(T)=ΔB/B+ΔB 0/B 0, and consequently Δk/k = 1/T (ΔB/B + ΔB$$_0$$/B$$_0$$ + Δ(pL)/(pL). Transmission is measured in the range of 0.2« less

  9. Iron Opacity Platform Performance Characterization at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Opachich, Y. P.; Ross, P. W.; Heeter, R. F.; Barrios, M. A.; Liedahl, D. A.; May, M. J.; Schneider, M. B.; Craxton, R. S.; Garcia, E. M.; McKenty, P. W.; Zhang, R.; Weaver, J. L.; Flippo, K. A.; Kline, J. L.; Perry, T. S.; Los Alamos National Laboratory Collaboration; Naval Research Laboratory Collaboration; University of Rochester LaboratoryLaser Energetics Collaboration; Lawrence Livermore National Lab Collaboration; National Security Technologies, LLC Collaboration

    2016-10-01

    A high temperature opacity platform has been fielded at the National Ignition Facility (NIF). The platform will be used to study opacity in iron at a temperature of 160 eV. The platform uses a 6 mm diameter hohlraum driven by 128 laser beams with 530 kJ of energy in a 3 ns pulse to heat an iron sample. Absorption spectra of the heated sample are generated with a broadband pulsed X-ray backlighter produced by imploding a vacuum-filled CH shell. The shell is 2 mm in diameter and 20 microns thick, driven by 64 beams with 250 kJ in a 2.5 ns pulse. The hohlraum and backlighter performance have both been investigated recently and will be discussed in this presentation. This work was performed by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946-2892.

  10. Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

    DOE PAGES

    Opachich, Y. P.; Heeter, R. F.; Barrios, M. A.; ...

    2017-06-08

    Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500–2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ~20 μm thickness have been performed. X-ray yields of up to ~1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ~100 μm FWHM, with ~350 ps pulse duration during the peak emission stage. Lastly, these results are used to simulate transmission spectramore » for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.« less

  11. Lighting, backlighting and watercolor illusions and the laws of figurality.

    PubMed

    Pinna, Baingio; Reeves, Adam

    2006-01-01

    We report some novel 'lighting' and 'backlighting' effects in plane figures similar to those which induce the 'watercolor illusion', that is, figures made with outlines composed of juxtaposed parallel lines varying in brightness and chromatic color. These new effects show 'illumination' as an emergent percept, and show how arrangements of 'dark and light' along the boundaries of various plane figures model the volume and strengthen the illusion of depth. To account for these various effects we propose several phenomenological 'laws of figurality' to add to the Gestalt laws of organization and figure-ground segregation. We offer a set of meta-laws which are speculative but which serve to integrate and organize the phenomenological laws. These laws indicate how luminance gradient profiles across boundary contours define both the 3D appearance of figures and the properties of the light reflected from their volumetric shapes.

  12. Electrochromic projection and writing device

    DOEpatents

    Branz, Howard M.; Benson, David K.

    2002-01-01

    A display and projection apparatus includes an electrochromic material and a photoconductive material deposited in tandem used in conjunction with a light filtering means for filtering light transmitted through the electrochromic material. When an electric field is applied across the electrochromic material and the photoconductive material, light that is incident onto the photoconductive material through the surface of the projection apparatus causes the photoconductive material to conduct current locally in proportion to the amount of light incident on the photoconductive material. The flow of current causes the underlying portions of the electrochromic material to switch from an opaque state to a clear or transmissive state, thereby allowing back-light to propagate through the electrochromic material to create a visible image on the surface of the projection apparatus. Reversal of the electric field causes the electrochromic material to revert back to its opaque state, thereby blocking the transmission of back-light and effectively erasing the image from the surface of the projection apparatus.

  13. Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility.

    PubMed

    Opachich, Y P; Heeter, R F; Barrios, M A; Garcia, E M; Craxton, R S; King, J A; Liedahl, D A; McKenty, P W; Schneider, M B; May, M J; Zhang, R; Ross, P W; Kline, J L; Moore, A S; Weaver, J L; Flippo, K A; Perry, T S

    2017-06-01

    Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ∼20  μ m thickness have been performed. X-ray yields of up to ∼1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ∼100  μ m FWHM, with ∼350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

  14. Impact of different cleaning processes on the laser damage threshold of antireflection coatings for Z-Backlighter optics at Sandia National Laboratories

    DOE PAGES

    Field, Ella; Bellum, John; Kletecka, Damon

    2014-11-06

    We have examined how different cleaning processes affect the laser-induced damage threshold of antireflection coatings for large dimension, Z-Backlighter laser optics at Sandia National Laboratories. Laser damage thresholds were measured after the coatings were created, and again 4 months later to determine which cleaning processes were most effective. There is a nearly twofold increase in laser-induced damage threshold between the antireflection coatings that were cleaned and those that were not cleaned. Aging of the coatings after 4 months resulted in even higher laser-induced damage thresholds. Also, the laser-induced damage threshold results revealed that every antireflection coating had a high defectmore » density, despite the cleaning process used, which indicates that improvements to either the cleaning or deposition processes should provide even higher laser-induced damage thresholds.« less

  15. Directional backlight liquid crystal autostereoscopic display: technical challenges, research progress, and prospect (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Fan, Hang; Li, Kunyang; Zhou, Yangui; Liang, Haowen; Wang, Jiahui; Zhou, Jianying

    2016-09-01

    Recent upsurge on virtual and augmented realities (VR and AR) has re-ignited the interest to the immerse display technology. The VR/AR technology based on stereoscopic display is believed in its early stage as glasses-free, or autostereoscopic display, will be ultimately adopted for the viewing convenience, visual comfort and for the multi-viewer purposes. On the other hand, autostereoscopic display has not yet received positive market response for the past years neither with stereoscopic displays using shutter or polarized glasses. We shall present the analysis on the real-world applications, rigid user demand, the drawbacks to the existing barrier- and lenticular lens-based LCD autostereoscopy. We shall emphasize the emerging autostereoscopic display, and notably on directional backlight LCD technology using a hybrid spatial- and temporal-control scenario. We report the numerical simulation of a display system using Monte-Carlo ray-tracing method with the human retina as the real image receiver. The system performance is optimized using newly developed figure of merit for system design. The reduced crosstalk in an autostereoscopic system, the enhanced display quality, including the high resolution received by the retina, the display homogeneity without Moiré- and defect-pattern, will be highlighted. Recent research progress including a novel scheme for diffraction-free backlight illumination, the expanded viewing zone for autostereoscopic display, and the novel Fresnel lens array to achieve a near perfect display in 2D/3D mode will be introduced. The experimental demonstration will be presented to the autostereoscopic display with the highest resolution, low crosstalk, Moiré- and defect- pattern free.

  16. 77 FR 65579 - Certain Devices for Improving Uniformity Used in a Backlight Module and Components Thereof and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-29

    ... Determination and Recommended Determination on Remedy and Bonding in the above-captioned investigation. The... Recommended Determination on Remedy and Bonding issued in this investigation on October 22, 2012. Comments...

  17. In situ determination of flocculated suspended material settling velocities and characteristics using a floc camera

    USGS Publications Warehouse

    Schoellhamer, David H.; Haught, Dan; Manning, Andrew

    2012-01-01

    Estimates of suspended sediment settling are necessary for numerical sediment models, water quality studies, and rehabilitation of coastal ecosystems. Settling of cohesive sediment, which is common in estuaries, is more difficult to quantify than noncohesive sediment because of flocculation. Flocs are composed of an aggregation of finer silts, clays, and organic material. Floc characteristics, such as the diameter, density, porosity, and water content determine floc settling velocities. A floc camera provides the ability to capture the settling velocities and other desired characteristics of individual flocs in situ. Water samples taken using a Van Dorn sampler are immediately subsampled using a pipette and transferred to the floc camera. The Perspex settling column is outfitted with a LED backlighting to distinguish flocs. The floc camera’s high pixel and temporal resolution allows image analysis software to detect individual flocs and process floc statistics per image. Observed changes in floc location with respect to time presents a way of calculating settling velocities. This work presents results of validation tests with known sediment size distributions and of deployment of the camera during a field study.

  18. Luminescence in Sulfides: A Rich History and a Bright Future

    PubMed Central

    Smet, Philippe F.; Moreels, Iwan; Hens, Zeger; Poelman, Dirk

    2010-01-01

    Sulfide-based luminescent materials have attracted a lot of attention for a wide range of photo-, cathodo- and electroluminescent applications. Upon doping with Ce3+ and Eu2+, the luminescence can be varied over the entire visible region by appropriately choosing the composition of the sulfide host. Main application areas are flat panel displays based on thin film electroluminescence, field emission displays and ZnS-based powder electroluminescence for backlights. For these applications, special attention is given to BaAl2S4:Eu, ZnS:Mn and ZnS:Cu. Recently, sulfide materials have regained interest due to their ability (in contrast to oxide materials) to provide a broad band, Eu2+-based red emission for use as a color conversion material in white-light emitting diodes (LEDs). The potential application of rare-earth doped binary alkaline-earth sulfides, like CaS and SrS, thiogallates, thioaluminates and thiosilicates as conversion phosphors is discussed. Finally, this review concludes with the size-dependent luminescence in intrinsic colloidal quantum dots like PbS and CdS, and with the luminescence in doped nanoparticles.

  19. Optimizing density patterns to achieve desired light extraction for displays

    NASA Astrophysics Data System (ADS)

    Davenport, T. L. R.; Cassarly, W. J.

    2007-01-01

    In displays such as backlights and signage, it is often desirable to produce a particular spatial luminance distribution of light. This work demonstrates an iterative optimization technique for determining the density of light extractors required to produce desired luminance distributions.

  20. Optical damage testing at the Z-Backlighter facility at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Kimmel, Mark; Rambo, Patrick; Broyles, Robin; Geissel, Matthias; Schwarz, Jens; Bellum, John; Atherton, Briggs

    2009-10-01

    To enable laser-based radiography of high energy density physics events on the Z-Accelerator[4,5] at Sandia National Laboratories, a facility known as the Z-Backlighter has been developed. Two Nd:Phosphate glass lasers are used to create x-rays and/or proton beams capable of this radiographic diagnosis: Z-Beamlet (a multi-kilojoule laser operating at 527nm in a few nanoseconds) and Z-Petawatt (a several hundred joule laser operating at 1054nm in the subpicosecond regime) [1,2]. At the energy densities used in these systems, it is necessary to use high damage threshold optical materials, some of which are poorly characterized (especially for the sub-picosecond pulse). For example, Sandia has developed a meter-class dielectric coating capability for system optics. Damage testing can be performed by external facilities for nanosecond 532nm pulses, measuring high reflector coating damage thresholds >80J/cm2 and antireflection coating damage thresholds >20J/cm2 [3]. However, available external testing capabilities do not use femtosecond/picosecond scale laser pulses. To this end, we have constructed a sub-picoseond-laser-based optical damage test system. The damage tester system also allows for testing in a vacuum vessel, which is relevant since many optics in the Z-Backlighter system are used in vacuum. This paper will present the results of laser induced damage testing performed in both atmosphere and in vacuum, with 1054nm sub-picosecond laser pulses. Optical materials/coatings discussed are: bare fused silica and protected gold used for benchmarking; BK7; Zerodur; protected silver; and dielectric optical coatings (halfnia/silica layer pairs) produced by Sandia's in-house meter-class coating capability.

  1. What can the occult do for you?

    NASA Astrophysics Data System (ADS)

    Holwerda, B. W.; Keel, W. C.

    2017-03-01

    Interstellar dust is still a dominant uncertainty in Astronomy, limiting precision in e.g., cosmological distance estimates and models of how light is re-processed within a galaxy. When a foreground galaxy serendipitously overlaps a more distant one, the latter backlights the dusty structures in the nearer foreground galaxy. Such an overlapping or occulting galaxy pair can be used to measure the distribution of dust in the closest galaxy with great accuracy. The STARSMOG program uses Hubble to map the distribution of dust in foreground galaxies in fine (<100 pc) detail. Integral Field Unit (IFU) observations will map the effective extinction curve, disentangling the role of fine-scale geometry and grain composition on the path of light through a galaxy. The overlapping galaxy technique promises to deliver a clear understanding of the dust in galaxies: geometry, a probability function of dimming as a function of galaxy mass and radius, and its dependence on wavelength.

  2. Characterization of typical platelet injector flow configurations. [liquid propellant rocket engines

    NASA Technical Reports Server (NTRS)

    Hickox, C. E.

    1975-01-01

    A study to investigate the hydraulic atomization characteristics of several novel injector designs for use in liquid propellant rocket engines is presented. The injectors were manufactured from a series of thin stainless steel platelets through which orifices were very accurately formed by a photoetching process. These individual platelets were stacked together and the orifices aligned so as to produce flow passages of prescribed geometry. After alignment, the platelets were bonded into a single, 'platelet injector', unit by a diffusion bonding process. Because of the complex nature of the flow associated with platelet injectors, it was necessary to use experimental techniques, exclusively, throughout the study. Large scale models of the injectors were constructed from aluminum plates and the appropriate fluids were modeled using a glycerol-water solution. Stop-action photographs of test configurations, using spark-shadowgraph or stroboscopic back-lighting, are shown.

  3. Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

    NASA Technical Reports Server (NTRS)

    Lekan, Jack F.; Allen, Jeffrey S.

    1998-01-01

    Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

  4. 77 FR 6583 - Certain Devices for Improving Uniformity Used in a Backlight Module and Components Thereof and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... add as respondents LG Display Co., Ltd. of Seoul, South Korea and LG Display America, Inc. of San Jose..., South Korea; LG Electronics, Inc. of Seoul, South Korea; and LG Electronics, U.S.A., Inc. of Englewood...

  5. Analysis of circadian properties and healthy levels of blue light from smartphones at night.

    PubMed

    Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag

    2015-06-18

    This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display.

  6. Engineering of Semiconductor Nanocrystals for Light Emitting Applications

    PubMed Central

    Todescato, Francesco; Fortunati, Ilaria; Minotto, Alessandro; Signorini, Raffaella; Jasieniak, Jacek J.; Bozio, Renato

    2016-01-01

    Semiconductor nanocrystals are rapidly spreading into the display and lighting markets. Compared with liquid crystal and organic LED displays, nanocrystalline quantum dots (QDs) provide highly saturated colors, wide color gamut, resolution, rapid response time, optical efficiency, durability and low cost. This remarkable progress has been made possible by the rapid advances in the synthesis of colloidal QDs and by the progress in understanding the intriguing new physics exhibited by these nanoparticles. In this review, we provide support to the idea that suitably engineered core/graded-shell QDs exhibit exceptionally favorable optical properties, photoluminescence and optical gain, while keeping the synthesis facile and producing QDs well suited for light emitting applications. Solid-state laser emitters can greatly profit from QDs as efficient gain materials. Progress towards fabricating low threshold, solution processed DFB lasers that are optically pumped using one- and two-photon absorption is reviewed. In the field of display technologies, the exploitation of the exceptional photoluminescence properties of QDs for LCD backlighting has already advanced to commercial levels. The next big challenge is to develop the electroluminescence properties of QD to a similar state. We present an overview of QLED devices and of the great perspectives for next generation display and lighting technologies. PMID:28773794

  7. Gallium

    USGS Publications Warehouse

    Foley, Nora K.; Jaskula, Brian W.; Kimball, Bryn E.; Schulte, Ruth F.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Gallium is a soft, silvery metallic element with an atomic number of 31 and the chemical symbol Ga. Gallium is used in a wide variety of products that have microelectronic components containing either gallium arsenide (GaAs) or gallium nitride (GaN). GaAs is able to change electricity directly into laser light and is used in the manufacture of optoelectronic devices (laser diodes, light-emitting diodes [LEDs], photo detectors, and solar cells), which are important for aerospace and telecommunications applications and industrial and medical equipment. GaAs is also used in the production of highly specialized integrated circuits, semiconductors, and transistors; these are necessary for defense applications and high-performance computers. For example, cell phones with advanced personal computer-like functionality (smartphones) use GaAs-rich semiconductor components. GaN is used principally in the manufacture of LEDs and laser diodes, power electronics, and radio-frequency electronics. Because GaN power transistors operate at higher voltages and with a higher power density than GaAs devices, the uses for advanced GaN-based products are expected to increase in the future. Gallium technologies also have large power-handling capabilities and are used for cable television transmission, commercial wireless infrastructure, power electronics, and satellites. Gallium is also used for such familiar applications as screen backlighting for computer notebooks, flat-screen televisions, and desktop computer monitors.Gallium is dispersed in small amounts in many minerals and rocks where it substitutes for elements of similar size and charge, such as aluminum and zinc. For example, gallium is found in small amounts (about 50 parts per million) in such aluminum-bearing minerals as diaspore-boehmite and gibbsite, which form bauxite deposits, and in the zinc-sulfide mineral sphalerite, which is found in many mineral deposits. At the present time, gallium metal is derived mainly as a byproduct of the processing of bauxite ore for aluminum; lesser amounts of gallium metal are produced from the processing of sphalerite ore from three types of deposits (sediment-hosted, Mississippi Valley-type, and volcanogenic massive sulfide) for zinc. The United States is expected to meet its current and expected future needs for gallium through imports of primary, recycled, and refined gallium, as well as through domestic production of recycled and refined gallium. The U.S. Geological Survey estimates that world resources of gallium in bauxite exceed 1 billion kilograms, and a considerable quantity of gallium could be present in world zinc reserves.

  8. 49 CFR Appendix B to Part 234 - Alternate Methods of Protection Under 49 CFR 234.105(c), 234.106, and 234.107(c)

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Protection Under 49 CFR 234.105(c), 234.106, and 234.107(c) [This is a summary—see body of text for complete... pair of lights designed to flash alternatively, one light does not work (and back-lights from other...

  9. Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics

    ERIC Educational Resources Information Center

    Planinsic, Gorazd; Gojkosek, Mihael

    2011-01-01

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…

  10. Miniature Color Display Phase 4

    DTIC Science & Technology

    1993-05-01

    is used to generate full color. By spectral tuning of the xenon arc-lamp backlight and the color polarizers, a color gamut comparable to that of a...5 1.2 Phase IV Accom plishments ................................... 5 1.2.1 Subtractive Color Gamut ...Technical Achievem ents .............................................. 8 2.1 Subtractive Color Gamut 2.1.1 Sub Color LC Technology

  11. Intricate Valley Glaciers on Pluto

    NASA Image and Video Library

    2015-09-17

    The backlighting highlights the intricate flow lines on the glaciers. The flow front of the ice is moving into the informally named Sputnik Planum. The origin of the ridges and pits on the right side of the image remains uncertain. This image is 390 miles (630 kilometers) across. http://photojournal.jpl.nasa.gov/catalog/PIA19943

  12. Photometric study of single-shot energy-dispersive x-ray diffraction at a laser plasma facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoidn, O. R.; Seidler, G. T., E-mail: seidler@uw.edu

    The low repetition rates and possible shot-to-shot variations in laser-plasma studies place a high value on single-shot diagnostics. For example, white-beam scattering methods based on broadband backlighter x-ray sources are used to determine changes in the structure of laser-shocked crystalline materials by the evolution of coincidences of reciprocal lattice vectors and kinematically allowed momentum transfers. Here, we demonstrate that white-beam techniques can be extended to strongly disordered dense plasma and warm dense matter systems where reciprocal space is only weakly structured and spectroscopic detection is consequently needed to determine the static structure factor and thus, the ion-ion radial distribution function.more » Specifically, we report a photometric study of energy-dispersive x-ray diffraction (ED-XRD) for structural measurement of high energy density systems at large-scale laser facilities such as OMEGA and the National Ignition Facility. We find that structural information can be obtained in single-shot ED-XRD experiments using established backlighter and spectrometer technologies.« less

  13. The effect of the thicknesses of the various layers on the colour emitted by an organic electroluminescent device

    NASA Astrophysics Data System (ADS)

    Jolinat, P.; Clergereaux, R.; Farenc, J.; Destruel, P.

    1998-05-01

    Organic electroluminescent diodes based on thin organic layers are one of the most promising next-generation systems for the backlighting of the liquid crystal screens. Among other methods to obtain white light, three-layer luminescent devices with each layer emitting one of the three fundamental colours have been studied here. Red, green and blue light were produced by 0022-3727/31/10/018/img1 doped with Nile red, 0022-3727/31/10/018/img1 and TPD layers respectively. A fourth thin film of TAZ has been inserted between TPD and 0022-3727/31/10/018/img1 to control injection of electrons into the TPD. The effect of the layers' thicknesses on the spectral emission of the device has been examined. Results show that the thicknesses of TAZ and doped 0022-3727/31/10/018/img1 layers have to be controlled to within a precision of better than 5 Å. The discussion turns on the possibility of applying this technology to screen backlighting.

  14. Fully Solution-Processed Tandem White Quantum-Dot Light-Emitting Diode with an External Quantum Efficiency Exceeding 25.

    PubMed

    Jiang, Congbiao; Zou, Jianhua; Liu, Yu; Song, Chen; He, Zhiwei; Zhong, Zhenji; Wang, Jian; Yip, Hin-Lap; Peng, Junbiao; Cao, Yong

    2018-06-15

    Solution-processed electroluminescent tandem white quantum-dot light-emitting diodes (TWQLEDs) have the advantages of being low-cost and high-efficiency and having a wide color gamut combined with color filters, making this a promising backlight technology for high-resolution displays. However, TWQLEDs are rarely reported due to the challenge of designing device structures and the deterioration of film morphology with component layers that can be deposited from solutions. Here, we report an interconnecting layer with the optical, electrical, and mechanical properties required for fully solution-processed TWQLED. The optimized TWQLEDs exhibit a state-of-the-art current efficiency as high as 60.4 cd/A and an extremely high external quantum efficiency of 27.3% at a luminance of 100 000 cd/m 2 . A high color gamut of 124% NTSC 1931 standard can be achieved when combined with commercial color filters. These results represent the highest performance for solution-processed WQLEDs, unlocking the great application potential of TWQLEDs as backlights for new-generation displays.

  15. Visualizing density perturbations in the capsule shell in NIF implosions near peak velocity

    NASA Astrophysics Data System (ADS)

    Pickworth, L. A.; Hammel, B. A.; Smalyuk, V. A.; Macphee, A.; Scott, H. A.; Robey, H. F.; Field, J.; Barrios, M.; Regan, S. P.

    2016-10-01

    Engineering features on the capsule (surface roughness, support structures, etc.) can introduce outer surface perturbations that are ultimately detrimental to the performance of the capsule. Recent experiments have assessed minimal support structures and alternate pulse shapes using a re-entrant cone and back lighter that is perturbing to the implosion below radii of 500 μ m. Emission from the hot core, after shock-stagnation and prior to peak velocity (PV), has been used as a self-backlighter, providing a means to sample one side of the capsule at smaller radii. Adding high-Z gas ( 1 % Ar) to the capsule fill in Symcaps (4He), has produced a continuum backlighter with significant increase in emission at hv 8 keV over nominal fills. High-resolution imaging diagnostics with photon energy selectivity form 2D images of the transmitted self-emission, above and below the K-edge of an internally doped Cu layer. We can infer from these images the growth at PV of outer surface perturbations. Prepared by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-697620.

  16. Measuring the temperature history of isochorically heated warm dense metals

    NASA Astrophysics Data System (ADS)

    McGuffey, Chris; Kim, J.; Park, J.; Moody, J.; Emig, J.; Heeter, B.; Dozieres, M.; Beg, Fn; McLean, Hs

    2017-10-01

    A pump-probe platform has been designed for soft X-ray absorption spectroscopy near edge structure measurements in isochorically heated Al or Cu samples with temperature of 10s to 100s of eV. The method is compatible with dual picosecond-class laser systems and may be used to measure the temperature of the sample heated directly by the pump laser or by a laser-driven proton beam Knowledge of the temperature history of warm dense samples will aid equation of state measurements. First, various low- to mid-Z targets were evaluated for their suitability as continuum X-ray backlighters over the range 200-1800 eV using a 10 J picosecond-class laser with relativistic peak intensity Alloys were found to be more suitable than single-element backlighters. Second, the heated sample package was designed with consideration of target thickness and tamp layers using atomic physics codes. The results of the first demonstration attempts will be presented. This work was supported by the U.S. DOE under Contract No. DE-SC0014600.

  17. Ultrashort x-ray backlighters and applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umstadter, D., University of Michigan

    Previously, using ultrashort laser pulses focused onto solid targets, we have experimentally studied a controllable ultrafast broadband radiation source in the extreme ultraviolet for time-resolved dynamical studies in ultrafast science [J. Workman, A. Maksimchuk, X. Llu, U. Ellenberger, J. S. Coe, C.-Y. Chien, and D. Umstadter, ``Control of Bright Picosecond X-Ray Emission from Intense Sub- Picosecond Laser-Plasma Interactions,`` Phys. Rev. Lett. 75, 2324 (1995)]. Once armed with a bright ultrafast broadband continuum x-ray source and appropriate detectors, we used the source as a backlighter to study a remotely produced plasma. The application of the source to a problem relevant tomore » high-density matter completes the triad: creating and controlling, efficiently detecting, and applying the source. This work represented the first use of an ultrafast laser- produced x-ray source as a time-resolving probe in an application relevant to atomic, plasma and high-energy-density matter physics. Using the x-ray source as a backlighter, we adopted a pump-probe geometry to investigate the dynamic changes in electronic structure of a thin metallic film as it is perturbed by an ultrashort laser pulse. Because the laser deposits its energy in a skin depth of about 100 {Angstrom} before expansion occurs, up to gigabar pressure shock waves lasting picosecond in duration have been predicted to form in these novel plasmas. This raises the possibility of studying high- energy-density matter relevant to inertial confinement fusion (ICF) and astrophysics in small-scale laboratory experiments. In the past, time-resolved measurements of K-edge shifts in plasmas driven by nanosecond pulses have been used to infer conditions in highly compressed materials. In this study, we used 100-fs laser pulses to impulsively drive shocks into a sample (an untamped 1000 {Angstrom} aluminum film on 2000 {Angstrom} of parylene-n), measuring L-edge shifts.« less

  18. An optical technique for detecting minute-amplitude standing waves on a liquid jet

    NASA Astrophysics Data System (ADS)

    Takahashi, I.; Mori, Y. H.

    1995-10-01

    A liquid jet emerging from a nozzle or an orifice whose outlet is slightly elliptic has a series of minute-amplitude waves on its surface. A quite simple technique is proposed which enables detecting such waves even if they are no longer recognizable with the aid of ordinary backlighting of the jet.

  19. HST,survey views of Hubble after berthing in payload bay on Flight Day 3

    NASA Image and Video Library

    1997-02-13

    S82-E-5140 (13 Feb. 1997) --- A back-lighted full view of the Hubble Space Telescope (HST) in the grasp of the Remote Manipulation System (RMS) following capture early today. The limb of Earth forms part of the background. This view was taken with an Electronic Still Camera (ESC).

  20. Temperature rise induced by some light emitting diode and quartz-tungsten-halogen curing units.

    PubMed

    Asmussen, Erik; Peutzfeldt, Anne

    2005-02-01

    Because of the risk of thermal damage to the pulp, the temperature rise induced by light-curing units should not be too high. LED (light emitting diode) curing units have the main part of their irradiation in the blue range and have been reported to generate less heat than QTH (quartz-tungsten-halogen) curing units. This study had two aims: first, to measure the temperature rise induced by ten LED and three QTH curing units; and, second, to relate the measured temperature rise to the power density of the curing units. The light-induced temperature rise was measured by means of a thermocouple embedded in a small cylinder of resin composite. The power density was measured by using a dental radiometer. For LED units, the temperature rise increased with increasing power density, in a statistically significant manner. Two of the three QTH curing units investigated resulted in a higher temperature rise than LED curing units of the same power density. Previous findings, that LED curing units induce less temperature rise than QTH units, does not hold true in general.

  1. Electrophoresis Gel Quantification with a Flatbed Scanner and Versatile Lighting from a Screen Scavenged from a Liquid Crystal Display (LCD) Monitor

    ERIC Educational Resources Information Center

    Yeung, Brendan; Ng, Tuck Wah; Tan, Han Yen; Liew, Oi Wah

    2012-01-01

    The use of different types of stains in the quantification of proteins separated on gels using electrophoresis offers the capability of deriving good outcomes in terms of linear dynamic range, sensitivity, and compatibility with specific proteins. An inexpensive, simple, and versatile lighting system based on liquid crystal display backlighting is…

  2. Direct Growth of III-Nitride Nanowire-Based Yellow Light-Emitting Diode on Amorphous Quartz Using Thin Ti Interlayer

    NASA Astrophysics Data System (ADS)

    Prabaswara, Aditya; Min, Jung-Wook; Zhao, Chao; Janjua, Bilal; Zhang, Daliang; Albadri, Abdulrahman M.; Alyamani, Ahmed Y.; Ng, Tien Khee; Ooi, Boon S.

    2018-02-01

    Consumer electronics have increasingly relied on ultra-thin glass screen due to its transparency, scalability, and cost. In particular, display technology relies on integrating light-emitting diodes with display panel as a source for backlighting. In this study, we undertook the challenge of integrating light emitters onto amorphous quartz by demonstrating the direct growth and fabrication of a III-nitride nanowire-based light-emitting diode. The proof-of-concept device exhibits a low turn-on voltage of 2.6 V, on an amorphous quartz substrate. We achieved 40% transparency across the visible wavelength while maintaining electrical conductivity by employing a TiN/Ti interlayer on quartz as a translucent conducting layer. The nanowire-on-quartz LED emits a broad linewidth spectrum of light centered at true yellow color ( 590 nm), an important wavelength bridging the green-gap in solid-state lighting technology, with significantly less strain and dislocations compared to conventional planar quantum well nitride structures. Our endeavor highlighted the feasibility of fabricating III-nitride optoelectronic device on a scalable amorphous substrate through facile growth and fabrication steps. For practical demonstration, we demonstrated tunable correlated color temperature white light, leveraging on the broadly tunable nanowire spectral characteristics across red-amber-yellow color regime.

  3. Direct Growth of III-Nitride Nanowire-Based Yellow Light-Emitting Diode on Amorphous Quartz Using Thin Ti Interlayer.

    PubMed

    Prabaswara, Aditya; Min, Jung-Wook; Zhao, Chao; Janjua, Bilal; Zhang, Daliang; Albadri, Abdulrahman M; Alyamani, Ahmed Y; Ng, Tien Khee; Ooi, Boon S

    2018-02-06

    Consumer electronics have increasingly relied on ultra-thin glass screen due to its transparency, scalability, and cost. In particular, display technology relies on integrating light-emitting diodes with display panel as a source for backlighting. In this study, we undertook the challenge of integrating light emitters onto amorphous quartz by demonstrating the direct growth and fabrication of a III-nitride nanowire-based light-emitting diode. The proof-of-concept device exhibits a low turn-on voltage of 2.6 V, on an amorphous quartz substrate. We achieved ~ 40% transparency across the visible wavelength while maintaining electrical conductivity by employing a TiN/Ti interlayer on quartz as a translucent conducting layer. The nanowire-on-quartz LED emits a broad linewidth spectrum of light centered at true yellow color (~ 590 nm), an important wavelength bridging the green-gap in solid-state lighting technology, with significantly less strain and dislocations compared to conventional planar quantum well nitride structures. Our endeavor highlighted the feasibility of fabricating III-nitride optoelectronic device on a scalable amorphous substrate through facile growth and fabrication steps. For practical demonstration, we demonstrated tunable correlated color temperature white light, leveraging on the broadly tunable nanowire spectral characteristics across red-amber-yellow color regime.

  4. Analysis of circadian properties and healthy levels of blue light from smartphones at night

    PubMed Central

    Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag

    2015-01-01

    This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display. PMID:26085126

  5. Luminance requirements for lighted signage

    NASA Astrophysics Data System (ADS)

    Freyssinier, Jean Paul; Narendran, Nadarajah; Bullough, John D.

    2006-08-01

    Light-emitting diode (LED) technology is presently targeted to displace traditional light sources in backlighted signage. The literature shows that brightness and contrast are perhaps the two most important elements of a sign that determine its attention-getting capabilities and its legibility. Presently, there are no luminance standards for signage, and the practice of developing brighter signs to compete with signs in adjacent businesses is becoming more commonplace. Sign luminances in such cases may far exceed what people usually need for identifying and reading a sign. Furthermore, the practice of higher sign luminance than needed has many negative consequences, including higher energy use and light pollution. To move toward development of a recommendation for lighted signage, several laboratory human factors evaluations were conducted. A scale model of a storefront was used to present human subjects with a typical red channel-letter sign at luminances ranging from 8 cd/m2 to 1512 cd/m2 under four background luminances typical of nighttime outdoor and daytime inside-mall conditions (1, 100, 300, 1000 cd/m2), from three scaled viewing distances (30, 60, 340 ft), and either in isolation or adjacent to two similar signs. Subjects rated the brightness, acceptability, and ease of reading of the test sign for each combination of sign and background luminances and scaled viewing distances.

  6. Analysis of circadian properties and healthy levels of blue light from smartphones at night

    NASA Astrophysics Data System (ADS)

    Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag

    2015-06-01

    This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display.

  7. Halogen and LED light curing of composite: temperature increase and Knoop hardness.

    PubMed

    Schneider, L F; Consani, S; Correr-Sobrinho, L; Correr, A B; Sinhoreti, M A

    2006-03-01

    This study assessed the Knoop hardness and temperature increase provided by three light curing units when using (1) the manufacturers' recommended times of photo-activation and (2) standardizing total energy density. One halogen--XL2500 (3M/ESPE)--and two light-emitting diode (LED) curing units--Freelight (3M/ESPE) and Ultrablue IS (DMC)--were used. A type-K thermocouple registered the temperature change produced by the composite photo-activation in a mold. Twenty-four hours after the photo-activation procedures, the composite specimens were submitted to a hardness test. Both temperature increase and hardness data were submitted to ANOVA and Tukey's test (5% significance). Using the first set of photo-activation conditions, the halogen unit produced a statistically higher temperature increase than did both LED units, and the Freelight LED resulted in a lower hardness than did the other curing units. When applying the second set of photo-activation conditions, the two LED units produced statistically greater temperature increase than did the halogen unit, whereas there were no statistical differences in hardness among the curing units.

  8. Battery Charge Affects the Stability of Light Intensity from Light-emitting Diode Light-curing Units.

    PubMed

    Tongtaksin, A; Leevailoj, C

    This study investigated the influence of battery charge levels on the stability of light-emitting diode (LED) curing-light intensity by measuring the intensity from fully charged through fully discharged batteries. The microhardness of resin composites polymerized by the light-curing units at various battery charge levels was measured. The light intensities of seven fully charged battery LED light-curing units-1) LY-A180, 2) Bluephase, 3) Woodpecker, 4) Demi Plus, 5) Saab II, 6) Elipar S10, and 7) MiniLED-were measured with a radiometer (Kerr) after every 10 uses (20 seconds per use) until the battery was discharged. Ten 2-mm-thick cylindrical specimens of A3 shade nanofilled resin composite (PREMISE, Kerr) were prepared per LED light-curing unit group. Each specimen was irradiated by the fully charged light-curing unit for 20 seconds. The LED light-curing units were then used until the battery charge fell to 50%. Specimens were prepared again as described above. This was repeated again when the light-curing units' battery charge fell to 25% and when the light intensity had decreased to 400 mW/cm 2 . The top/bottom surface Knoop hardness ratios of the specimens were determined. The microhardness data were analyzed by one-way analysis of variance with Tukey test at a significance level of 0.05. The Pearson correlation coefficient was used to determine significant correlations between surface hardness and light intensity. We found that the light intensities of the Bluephase, Demi Plus, and Elipar S10 units were stable. The intensity of the MiniLED unit decreased slightly; however, it remained above 400 mW/cm 2 . In contrast, the intensities of the LY-A180, Woodpecker, and Saab II units decreased below 400 mW/cm 2 . There was also a significant decrease in the surface microhardnesses of the resin composite specimens treated with MiniLED, LY-A180, Woodpecker, and Saab II. In conclusion, the light intensity of several LED light-curing units decreased as the battery was discharged, with a coincident reduction in the units' ability to polymerize resin composite. Therefore, the intensity of an LED light-curing unit should be evaluated during the life of its battery charge to ensure that sufficient light intensity is being generated.

  9. Homogeneous free-form directional backlight for 3D display

    NASA Astrophysics Data System (ADS)

    Krebs, Peter; Liang, Haowen; Fan, Hang; Zhang, Aiqin; Zhou, Yangui; Chen, Jiayi; Li, Kunyang; Zhou, Jianying

    2017-08-01

    Realization of a near perfect homogeneous secondary emission source for 3D display is proposed and demonstrated. The light source takes advantage of an array of free-form emission surface with a specially tailored light guiding structure, a light diffuser and Fresnel lens. A seamless and homogeneous directional emission is experimentally obtained which is essential for a high quality naked-eye 3D display.

  10. 78 FR 26068 - Certain Devices for Improving Uniformity Used in a Backlight Module and Components Thereof and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ... and bonding. In particular, the ALJ found that claims 6, 9 and 10 of the `932 patent are not infringed literally or under the Doctrine of Equivalents by the accused products under his construction of the claim... containing same by reason of infringement of certain claims of U.S. Patent No. 6,883,932 (``the `932 patent...

  11. Evaluation of an LED (Light-Emitting Diode) high-mounted signal lamp

    NASA Astrophysics Data System (ADS)

    Olson, P. L.

    1987-02-01

    Two studies are described evaluating high-mounted stoplights using light-emitting diodes (LEDs) compared with conventional incandescent units. The first of these studies obtained ratings from subjects who drove one car and followed another car that was equipped with the test lamps. The results indicate that the subjects generally preferred the LEDs to the conventional lamp. The second study was a laboratory evaluation of the attention-getting capabilities of LED and incandescent stoplights. Under all conditions tested subjects responded faster to the LED units. The response time advantage for the LED units increased with more difficult viewing conditions, such as high levels of illumination and long viewing distance. The results of these investigations are discussed in terms of the applicability of the LED technology to high mounted stoplights on motor vehicles.

  12. Efficiency of dual-cured resin cement polymerization induced by high-intensity LED curing units through ceramic material.

    PubMed

    Watanabe, H; Kazama, Re; Asai, T; Kanaya, F; Ishizaki, H; Fukushima, M; Okiji, T

    2015-01-01

    This study aimed to evaluate the ability of high-intensity light-emitting diode (LED) and other curing units to cure dual-cured resin cement through ceramic material. A halogen curing unit (Jetlite 3000, Morita), a second-generation LED curing unit (Demi, Kerr), and two high-intensity LED curing units (PenCure 2000, Morita; Valo, Ultradent) were tested. Feldspathic ceramic plates (VITABLOCS Mark II, A3; Vita Zahnfabrik) with thicknesses of 1.0, 2.0, and 3.0 mm were prepared. Dual-cured resin cement samples (Clearfil Esthetic Cement, Kuraray Noritake Dental) were irradiated directly or through one of the ceramic plates for different periods (5, 10, 15, or 20 seconds for the high-intensity LED units and 20, 40, 60, or 80 seconds for the others). The Knoop hardness test was used to determine the level of photopolymerization that had been induced in the resin cement. Data were analyzed by one-way analysis of variance and Dunnett's post-hoc test to identify test-control (maximum irradiation without a ceramic plate) differences for each curing unit (p<0.05). For all curing units, the curing conditions had a statistically significant effect on the Knoop hardness numbers (KHNs) of the irradiated cement samples (p<0.001). In general, the KHN decreased with increasing plate thickness and increased as the irradiation period was extended. Jetlite 3000 achieved control-level KHN values only when the plate thickness was 1.0 mm. At a plate thickness ≥2.0 mm, the LED units (except for PenCure 2000 at 3.0 mm) were able to achieve control-level KHN values when the irradiation time was extended. At a plate thickness of 3.0 mm, irradiation for 20 seconds with the Valo or for 80 seconds with the Demi were the only methods that produced KHN values equivalent to those produced by direct irradiation. Regardless of the type of curing unit used, indirect irradiation of dual-cured resin cement through a ceramic plate resulted in decreased KHN values compared with direct irradiation. When the irradiation period was extended, only the LED units were able to achieve similar KHN values to those observed under direct irradiation in the presence of plates ≥2.0-mm thick. High-intensity LED units require a shorter irradiation period than halogen and second-generation LED curing units to obtain KHN values similar to those observed during direct irradiation.

  13. Development and Characterization of a 16.3 keV X-Ray Source at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Fournier, K. B.; Barrios, M. A.; Schneider, M. B.; Khan, S.; Chen, H.; Coppari, F.; Rygg, R.; Hohenberger, M.; Albert, F.; Moody, J.; Ralph, J.; Kemp, G. E.; Regan, S. P.

    2014-10-01

    X-ray sources at the National Ignition Facility are needed for radiography of in-flight capsules in inertial confinement fusion experiments and for diffraction studies of materials at high pressures. In the former case, we want to optimize signal to noise and signal over background ratios for the radiograph, in the latter case, we want to minimize high-energy emission from the backlighter that creates background on the diffraction data. Four interleaved shots at NIF were taken in one day, with laser irradiances on a Zr backlighter target ranging from 5 to 14 × 1015 W/cm2. Two shots were for source optimization as a function of laser irradiance. X-ray fluxes were measured with the time-resolved NIF X-ray Spectrometer (NXS) and the DANTE array of calibrated, filtered diodes. Two shots were optimized to make backscatter measurements with the FABS and NBI optical power systems. The backscatter levels are investigated to look for correlation with hot electron populations inferred from high-energy x rays measured with the FFLEX broadband spectrometer. Results from all shots are presented and compared with models. Work performed under the auspices of the U.S. DOE by LLNL under Contract No. DE-AC52-07NA27344.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Kevin L.

    The purpose of this LDRD project was to demonstrate high spatial and temporal resolution x-ray imaging using optical detectors, and in particular the VISAR and OHRV diagnostics on the OMEGA laser. The x-ray source being imaged was a backlighter capsule being imploded by 39 beams of the OMEGA laser. In particular this approach utilized a semiconductor with the side facing the backlighter capsule coated with a thin aluminum layer to allow x rays to pass through the metal layer and then get absorbed in the semiconductor. The other side of the semiconductor was AR coated to allow the VISAR ormore » OHRV probe beam to sample the phase change of the semiconductor as the x rays were absorbed in the semiconductor. This technique is capable of acquiring sub-picosecond 2-D or 1-D x-ray images, detector spatial resolution of better than 10 um and the ability to operate in a high neutron flux environment expected on ignition shots with burning plasmas. In addition to demonstrating this technique on the OMEGA laser, several designs were made to improve the phase sensitivity, temporal resolution and number of frames over the existing diagnostics currently implemented on the OMEGA laser. These designs included both 2-d imaging diagnostics as well as improved 1-D imaging diagnostics which were streaked in time.« less

  15. Comparison of halogen, plasma and LED curing units.

    PubMed

    Nomoto, Rie; McCabe, John F; Hirano, Susumu

    2004-01-01

    This study evaluated the characteristics of two kinds of recently developed light-curing unit; plasma arc and blue light emitting diodes (LED), in comparison with a conventional tungsten-halogen light-curing unit. The light intensity and spectral distribution of light from these light-curing units, the temperature rise of the bovine enamel surface and the depth of cure of composites exposed to each unit were investigated. The light intensity and depth of cure were determined according to ISO standards. The spectral distributions of emitted light were measured using a spectro-radiometer. The temperature increase induced by irradiation was measured by using a thermocouple. Generally, light intensities in the range 400-515 nm emitted from the plasma arc were greater than those from other types. Light in the UV-A region was emitted from some plasma arc units. The required irradiation times were six to nine seconds for the plasma arc units and 40 to 60 seconds for the LED units to create a depth of cure equal to that produced by the tungsten-halogen light with 20 seconds of irradiation. The temperature increased by increasing the irradiation time for every light-curing unit. The temperature increases were 15 degrees C to 60 degrees C for plasma arc units, around 15 degrees C for a conventional halogen unit and under 10 degrees C for LED units. Both the plasma arc and LED units required longer irradiation times than those recommended by their respective manufacturers. Clinicians should be aware of potential thermal rise and UV-A hazard when using plasma arc units.

  16. Beginning an action research project to investigate the feasibility of a midwife-led normal birthing unit in China.

    PubMed

    Mander, Rosemary; Cheung, Ngai Fen; Wang, Xiaoli; Fu, Wei; Zhu, Junghong

    2010-02-01

    To explore issues arising during preliminary stages of a research project in order to consider the feasibility of a midwife-led normal birthing unit in mainland China. Midwife-led normal birthing units, as a route to ensuring normality, have become a feature of western maternity care, but are unknown in China. Action research, using a qualitative descriptive approach, was performed. Data were collected at meetings, by non-participant observation and by face-to-face semi-structured interviews. Observation was undertaken in the midwife-led normal birthing unit and a standard care setting. Data analysis was by thematic analysis using constant comparison techniques. In the labour ward of a large general hospital in a major city, stakeholders included midwifery staff, managers, university staff and researchers. Childbearing women proved keen to use this service, but were unable to participate in the planning. The midwife-led normal birthing unit sought to provide one-to-one care in labour and support by a birth companion. Routine interventions were to be avoided. The midwives in the midwife-led normal birthing unit created a more suitable environment for supportive care. The midwives demonstrated high-quality communication skills. The woman's choice of position/mobility was limited. Difficulties with staffing were identified. The preliminary findings suggest that continuation of the project is feasible. The woman's role demonstrates passivity. The perception of staff shortage has serious implications. This action research project suggests that a study of a midwife-led normal birthing unit in China is feasible, with some attention to staffing issues.

  17. Intensity output and effectiveness of light curing units in dental offices.

    PubMed

    Omidi, Baharan-Ranjbar; Gosili, Armin; Jaber-Ansari, Mona; Mahdkhah, Ailin

    2018-06-01

    The aims of the study were measuring the light intensity of light curing units used in Qazvin's dental offices, determining the relationship between the clinical age of these units and their light intensity, and identifying the reasons for repairing them. In this cross-sectional study, the output intensity of 95 light curing devices was evaluated using a radiometer. The average output intensity was divided up into four categories (less than 200, 200-299, 300-500, and more than 500 mW/cm2). In addition, a questionnaire was designed to obtain information mainly about the type, clinical age, and frequency of maintenance of the units and the reasons for fixing them. Data were analyzed using Kolmogorov-Smirnov, chi-squared, and t-tests ( p < 0.05) on SPSS 24. A total of 95 light curing units were examined, with 61 (64.2%) of them being of the LED type and 34 (35.8%) of the QTH type. While average light intensity in LED units was significantly higher than in QTH devices, the two device types were not significantly different regarding desirable light intensity (i.e., ≥ 300 mw/cm2). A negative correlation was observed between clinical age and light intensity. In addition, bulb replacement in QTH devices was over three times as much as in LED units. Also, repairing QTHs was more than twice as much frequent as fixing LEDs. The most common reason for repair was the breakage of the tip of the device. The light intensity of LED units is significantly higher than that of QTH devices, and the frequency of repairing in QTHs was significantly more than in LEDs. Furthermore, light intensity decreases with aging, and dentists should regularly monitor the conditions of light units. Key words: Light curing unit, radiometer, light intensity, dental equipment, dental offices.

  18. Ride-along data LOS 130, 170 & LO330 shots z3139, 3140 and 3141

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loisel, Guillaume Pascal

    Each instrument records the x-ray emission from the Z-pinch dynamic hohlraum (ZPDH); LOS 130 TIXTLs instruments record the absorption of the pinch backlighter through an expanding NaF/Mg foil; LOS 170 MLM instruments record monochromatic images at 276 and 528 eV energies near and before ZPDH stagnation time; LOS 330 TREX 6A & B: recoded time resolved absorption spectra from a radiatively heated Ne gas.

  19. The Experimental Study of Rayleigh-Taylor Instability using a Linear Induction Motor Accelerator

    NASA Astrophysics Data System (ADS)

    Yamashita, Nicholas; Jacobs, Jeffrey

    2009-11-01

    The experiments to be presented utilize an incompressible system of two stratified miscible liquids of different densities that are accelerated in order to produce the Rayleigh-Taylor instability. Three liquid combinations are used: isopropyl alcohol with water, a calcium nitrate solution or a lithium polytungstate solution, giving Atwood numbers of 0.11, 0.22 and 0.57, respectively. The acceleration required to drive the instability is produced by two high-speed linear induction motors mounted to an 8 m tall drop tower. The motors are mounted in parallel and have an effective acceleration length of 1.7 m and are each capable of producing 15 kN of thrust. The liquid system is contained within a square acrylic tank with inside dimensions 76 x76x184 mm. The tank is mounted to an aluminum plate, which is driven by the motors to create constant accelerations in the range of 1-20 g's, though the potential exists for higher accelerations. Also attached to the plate are a high-speed camera and an LED backlight to provide continuous video of the instability. In addition, an accelerometer is used to provide acceleration measurements during each experiment. Experimental image sequences will be presented which show the development of a random three-dimensional instability from an unforced initial perturbation. Measurements of the mixing zone width will be compared with traditional growth models.

  20. IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING

    PubMed Central

    Carrasco, Thaise Graciele; Carrasco-Guerisoli, Laise Daniela; Fröner, Izabel Cristina

    2008-01-01

    This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)-laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66°C). The LED unit produced the lowest temperature increase (0.29±0.13°C); but there was no significant difference between LED unit and LED-laser system (0.35±0.15°C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64°C), and LED-laser system the lowest (0.33±0.12°C); however, there was no difference between LED-laser system and LED unit (0.44±0.11°C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health. PMID:19089234

  1. 77 FR 77092 - Certain Devices for Improving Uniformity Used in a Backlight Module and Components Thereof and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-31

    ...Notice is hereby given that the U.S. International Trade Commission has determined to review the presiding administrative law judge's (``ALJ'') final initial determination (``ID'') issued on October 22, 2012, finding no violation of section 337 of the Tariff Act of 1930, (as amended), 19 U.S.C. 1337 (``section 337''), in the above- captioned investigation. The Commission has also determined to remand- in-part the investigation to the ALJ.

  2. Electrophoretic display technologies for e-book readers: system integration aspects

    NASA Astrophysics Data System (ADS)

    Gentric, Philippe

    2011-03-01

    Emerging screen technologies, such as Electrophoretic Displays (EPD) used in E-book Readers, are changing product power requirements due to their advantageous properties such as bi-stability (effective "zero power" static display) and reflective mode of operation (no backlight). We will first review the emerging screen technologies under the angle of system and IC design impact. We will explain power management consequences for IC design, with a focus on Application Engine SOCs for the wireless/portable markets.

  3. Refraction-enhanced backlit imaging of axially symmetric inertial confinement fusion plasmas.

    PubMed

    Koch, Jeffrey A; Landen, Otto L; Suter, Laurence J; Masse, Laurent P; Clark, Daniel S; Ross, James S; Mackinnon, Andrew J; Meezan, Nathan B; Thomas, Cliff A; Ping, Yuan

    2013-05-20

    X-ray backlit radiographs of dense plasma shells can be significantly altered by refraction of x rays that would otherwise travel straight-ray paths, and this effect can be a powerful tool for diagnosing the spatial structure of the plasma being radiographed. We explore the conditions under which refraction effects may be observed, and we use analytical and numerical approaches to quantify these effects for one-dimensional radial opacity and density profiles characteristic of inertial-confinement fusion (ICF) implosions. We also show how analytical and numerical approaches allow approximate radial plasma opacity and density profiles to be inferred from point-projection refraction-enhanced radiography data. This imaging technique can provide unique data on electron density profiles in ICF plasmas that cannot be obtained using other techniques, and the uniform illumination provided by point-like x-ray backlighters eliminates a significant source of uncertainty in inferences of plasma opacity profiles from area-backlit pinhole imaging data when the backlight spatial profile cannot be independently characterized. The technique is particularly suited to in-flight radiography of imploding low-opacity shells surrounding hydrogen ice, because refraction is sensitive to the electron density of the hydrogen plasma even when it is invisible to absorption radiography. It may also provide an alternative approach to timing shockwaves created by the implosion drive, that are currently invisible to absorption radiography.

  4. Dynamic granularity of imaging systems

    DOE PAGES

    Geissel, Matthias; Smith, Ian C.; Shores, Jonathon E.; ...

    2015-11-04

    Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” G dyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environmentmore » rather than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.« less

  5. Multi-keV X-ray area source intensity at SGII laser facility

    NASA Astrophysics Data System (ADS)

    Wang, Rui-rong; An, Hong-hai; Xie, Zhi-yong; Wang, Wei

    2018-05-01

    Experiments for investigating the feasibility of multi-keV backlighters for several different metallic foil targets were performed at the Shenguang II (SGII) laser facility in China. Emission spectra in the energy range of 1.65-7.0 keV were measured with an elliptically bent crystal spectrometer, and the X-ray source size was measured with a pinhole camera. The X-ray intensity near 4.75 keV and the X-ray source size for titanium targets at different laser intensity irradiances were studied. By adjusting the total laser energy at a fixed focal spot size, laser intensity in the range of 1.5-5.0 × 1015 W/cm2, was achieved. The results show that the line emission intensity near 4.75 keV and the X-ray source size are dependent on the laser intensity and increase as the laser intensity increases. However, an observed "peak" in the X-ray intensity near 4.75 keV occurs at an irradiance of 4.0 × 1015 W/cm2. For the employed experimental conditions, it was confirmed that the laser intensity could play a significant role in the development of an efficient multi-keV X-ray source. The experimental results for titanium indicate that the production of a large (˜350 μm in diameter) intense backlighter source of multi-keV X-rays is feasible at the SGII facility.

  6. Fast-response LCDs for virtual reality applications

    NASA Astrophysics Data System (ADS)

    Chen, Haiwei; Peng, Fenglin; Gou, Fangwang; Wand, Michael; Wu, Shin-Tson

    2017-02-01

    We demonstrate a fast-response liquid crystal display (LCD) with an ultra-low-viscosity nematic LC mixture. The measured average motion picture response time is only 6.88 ms, which is comparable to 6.66 ms for an OLED at a 120 Hz frame rate. If we slightly increase the TFT frame rate and/or reduce the backlight duty ratio, image blurs can be further suppressed to unnoticeable level. Potential applications of such an image-blur-free LCD for virtual reality, gaming monitors, and TVs are foreseeable.

  7. Two stacked tandem white organic light-emitting diodes employing WO3 as a charge generation layer

    NASA Astrophysics Data System (ADS)

    Bin, Jong-Kwan; Lee, Na Yeon; Lee, SeungJae; Seo, Bomin; Yang, JoongHwan; Kim, Jinook; Yoon, Soo Young; Kang, InByeong

    2016-09-01

    Recently, many studies have been conducted to improve the electroluminescence (EL) performance of organic lightemitting diodes (OLEDs) by using appropriate organic or inorganic materials as charge generation layer (CGL) for their application such as full color displays, backlight units, and general lighting source. In a stacked tandem white organic light-emitting diodes (WOLEDs), a few emitting units are electrically interconnected by a CGL, which plays the role of generating charge carriers, and then facilitate the injection of it into adjacent emitting units. In the present study, twostacked WOLEDs were fabricated by using tungsten oxide (WO3) as inorganic charge generation layer and 1,4,5,8,9,11- hexaazatriphenylene hexacarbonitrile (HAT-CN) as organic charge generation layer (P-CGL). Organic P-CGL materials were used due to their ease of use in OLED fabrication as compared to their inorganic counterparts. To obtain high efficiency, we demonstrate two-stacked tandem WOLEDs as follows: ITO/HIL/HTL/HTL'/B-EML/ETL/N-CGL/P-CGL (WO3 or HAT-CN)/HTL″/YG-EML/ETL/LiF/Al. The tandem devices with blue- and yellow-green emitting layers were sensitive to the thickness of an adjacent layer, hole transporting layer for the YG emitting layer. The WOLEDs containing the WO3 as charge generation layer reach a higher power efficiency of 19.1 lm/W and the current efficiency of 51.2 cd/A with the white color coordinate of (0.316, 0.318) than the power efficiency of 13.9 lm/W, and the current efficiency of 43.7 cd/A for organic CGL, HAT-CN at 10 mA/cm2, respectively. This performance with inserting WO3 as CGL exhibited the highest performance with excellent CIE color coordinates in the two-stacked tandem OLEDs.

  8. Developing Successful International Faculty Led Program

    ERIC Educational Resources Information Center

    Fabregas Janeiro, Maria G.; Fabre, Ricardo Lopez; Rosete, Rodrigo Tello

    2012-01-01

    Faculty Led Programs are study abroad experiences led by university professors. Faculty Led Programs are considered as an opportunity for college students, especially in the United States to attend a short-term international experience (Mills, 2010). Faculty Led Program is an international experience which is different from the traditional…

  9. Effect of various visible light photoinitiators on the polymerization and color of light-activated resins.

    PubMed

    Arikawa, Hiroyuki; Takahashi, Hideo; Kanie, Takahito; Ban, Seiji

    2009-07-01

    The purpose of this study was to investigate effects of various visible light photoinitiators on the polymerization efficiency and color of the light-activated resins. Four photoinitiators, including camphorquinone, phenylpropanedione, monoacrylphosphine oxide (TPO), and bisacrylphosphine oxide (Ir819), were used. Each photoinitiator was dissolved in a Bis-GMA and TEGDMA monomer mixture. Materials were polymerized using dental quartz-tungsten halogen lamp (QTH), plasma-ark lamp and blue LED light-curing units, and a custom-made violet LED light unit. The degree of monomer conversion and CIE L*a*b* color values of the resins were measured using a FTIR and spectral transmittance meter. The degree of monomer conversions of TPO- and Ir819-containing resins polymerized with the violet-LED unit were higher than camphorquinone-containing resin polymerized with the QTH light-curing unit. The lowest color values were observed for the TPO-containing resin. Our results indicate that the TPO photoinitiator and the violet-LED light unit may provide a useful and improved photopolymerization system for dental light-activated resins.

  10. Stereoscopic-3D display design: a new paradigm with Intel Adaptive Stable Image Technology [IA-SIT

    NASA Astrophysics Data System (ADS)

    Jain, Sunil

    2012-03-01

    Stereoscopic-3D (S3D) proliferation on personal computers (PC) is mired by several technical and business challenges: a) viewing discomfort due to cross-talk amongst stereo images; b) high system cost; and c) restricted content availability. Users expect S3D visual quality to be better than, or at least equal to, what they are used to enjoying on 2D in terms of resolution, pixel density, color, and interactivity. Intel Adaptive Stable Image Technology (IA-SIT) is a foundational technology, successfully developed to resolve S3D system design challenges and deliver high quality 3D visualization at PC price points. Optimizations in display driver, panel timing firmware, backlight hardware, eyewear optical stack, and synch mechanism combined can help accomplish this goal. Agnostic to refresh rate, IA-SIT will scale with shrinking of display transistors and improvements in liquid crystal and LED materials. Industry could profusely benefit from the following calls to action:- 1) Adopt 'IA-SIT S3D Mode' in panel specs (via VESA) to help panel makers monetize S3D; 2) Adopt 'IA-SIT Eyewear Universal Optical Stack' and algorithm (via CEA) to help PC peripheral makers develop stylish glasses; 3) Adopt 'IA-SIT Real Time Profile' for sub-100uS latency control (via BT Sig) to extend BT into S3D; and 4) Adopt 'IA-SIT Architecture' for Monitors and TVs to monetize via PC attach.

  11. Fluid Interfaces of Triangular Containers in Reduced Gravity Environments

    NASA Technical Reports Server (NTRS)

    Guttromson, Jayleen; Manning, Robert; Collicott, Steven H.

    2002-01-01

    Capillary dominated fluid dynamics will be examined in a reduced-gravity environment onboard the KC-135; in particular, the behavior of the lower portion of the meniscus in triangular tank geometries. Seven clear acrylic tanks were constructed to view seven angles of the four geometries. Silicon oil with two different viscosities, 2cs and 5cs silicon oil, were used on different days of the flight. Six tanks and one control tank are filled with a certain viscosity fluid for each flight day. During each parabola, three tanks are tested at time. The experimental tanks are exchanged between parabola sets on the KC-135. The 60deg -60deg -60deg control tank is viewed throughout the flight. To gather data, two digital video cameras and one digital still camera are placed perpendicular the viewing surface. To provide a greater contrast in the meniscus, an EL backlighting sheet was used to backlight the tanks. These images and video are then digitized, passed through NASA's mini-tracker software, and compared to a theory published my M. M. Weislogel, "Fluid Interface Phenomena in a Low-Gravity Environment: Recent Results from Drop Tower Experimentation." By focusing on a lower portion of the meniscus and using longer periods of reduced gravity, this experiment may confirm that a stationary point exists on the fluid surface. This information will enable better designing of propellant management devices, especially satellite propellant refilling and gas venting. Also, biological and material processing systems in reduced gravity environments will benefit from this data.

  12. Inertial fusion program and national laser users facility program

    NASA Astrophysics Data System (ADS)

    1995-01-01

    This is the 1994 annual report for the University of Rochester, Laboratory for Laser Energetics. The report is presented as a series of research type reports. The titles emphasize the breadth of work carried out. They are: stability analysis of unsteady ablation fronts; characterization of laser-produced plasma density profiles using grid image refractometry; transport and sound waves in plasmas with light and heavy ions; three-halves-harmonic radiation from long-scale-length plasmas revisited; OMEGA upgrade status report; target imaging and backlighting diagnosis; effect of electron collisions on ion-acoustic waves and heat flow; particle-in-cell code simulations of the interaction of gaussian ultrashort laser pulses with targets of varying initial scale lengths; characterization of thick cryogenic fuel layers: compensation for the lens effect using convergent beam interferometry; compact, multijoule-output, Nd:Glass, large-aperture ring amplifier; atomic force microscopy observation of water-induced morphological changes in Y2O3 monolayer coatings; observation of longitudinal acceleration of electrons born in a high-intensity laser focus; spatial intensity nonuniformities of an OMEGA beam due to nonlinear beam propagation; calculated X-ray backlighting images of mixed imploded targets; evaluation of cosmic rays for use in the monitoring of the MEDUSA scintillator-photomultiplier diagnostic array; highly efficient second-harmonic generation of ultra-intense Nd:Glass laser pulses multiple cutoff wave numbers of the ablative Rayleigh-Taylor instability; ultrafast, all-silicon light modulator; angular dependence of the stimulated Brillouin scattering in homogeneous plasma; and femtosecond excited-state dynamics of a conjugated ladder polymer.

  13. Conceptual design of initial opacity experiments on the national ignition facility

    NASA Astrophysics Data System (ADS)

    Heeter, R. F.; Bailey, J. E.; Craxton, R. S.; Devolder, B. G.; Dodd, E. S.; Garcia, E. M.; Huffman, E. J.; Iglesias, C. A.; King, J. A.; Kline, J. L.; Liedahl, D. A.; McKenty, P. W.; Opachich, Y. P.; Rochau, G. A.; Ross, P. W.; Schneider, M. B.; Sherrill, M. E.; Wilson, B. G.; Zhang, R.; Perry, T. S.

    2017-02-01

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative-convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures eV and electron densities 21~\\text{cm}-3$ . The iron will be probed using continuum X-rays emitted in a ps, diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, of the NIF beams deliver 500 kJ to the mm diameter hohlraum, and the remaining directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.

  14. Zinc Alloys for the Fabrication of Semiconductor Devices

    NASA Technical Reports Server (NTRS)

    Ryu, Yungryel; Lee, Tae S.

    2009-01-01

    ZnBeO and ZnCdSeO alloys have been disclosed as materials for the improvement in performance, function, and capability of semiconductor devices. The alloys can be used alone or in combination to form active photonic layers that can emit over a range of wavelength values. Materials with both larger and smaller band gaps would allow for the fabrication of semiconductor heterostructures that have increased function in the ultraviolet (UV) region of the spectrum. ZnO is a wide band-gap material possessing good radiation-resistance properties. It is desirable to modify the energy band gap of ZnO to smaller values than that for ZnO and to larger values than that for ZnO for use in semiconductor devices. A material with band gap energy larger than that of ZnO would allow for the emission at shorter wavelengths for LED (light emitting diode) and LD (laser diode) devices, while a material with band gap energy smaller than that of ZnO would allow for emission at longer wavelengths for LED and LD devices. The amount of Be in the ZnBeO alloy system can be varied to increase the energy bandgap of ZnO to values larger than that of ZnO. The amount of Cd and Se in the ZnCdSeO alloy system can be varied to decrease the energy band gap of ZnO to values smaller than that of ZnO. Each alloy formed can be undoped or can be p-type doped using selected dopant elements, or can be n-type doped using selected dopant elements. The layers and structures formed with both the ZnBeO and ZnCdSeO semiconductor alloys - including undoped, p-type-doped, and n-type-doped types - can be used for fabricating photonic and electronic semiconductor devices for use in photonic and electronic applications. These devices can be used in LEDs, LDs, FETs (field effect transistors), PN junctions, PIN junctions, Schottky barrier diodes, UV detectors and transmitters, and transistors and transparent transistors. They also can be used in applications for lightemitting display, backlighting for displays, UV and visible transmitters and detectors, high-frequency radar, biomedical imaging, chemical compound identification, molecular identification and structure, gas sensors, imaging systems, and for the fundamental studies of atoms, molecules, gases, vapors, and solids.

  15. Experimental study of combustion processes involved in hypergolic propellant coaxial injector operation

    NASA Astrophysics Data System (ADS)

    Habiballah, M.; Dubois, I.; Gicquel, P.; Foucaud, R.

    1992-07-01

    The first results are presented of an experimental research program to understand the operation of a coaxial injector using hypergolic propellants. Mechanisms and processes involved in coaxial injector operation are identified for a two-plate injector and a coaxial injector. The usefulness of backlight cinematography and laser sheet visualization in the study of coaxial injector operation is examined. A review of the literature on injector elements using highly reactive hypergolic propellants is presented along with an analysis of fundamental mechanisms involved in these propellants.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casey, D. T., E-mail: casey21@llnl.gov; Munro, D. H.; Grim, G. P.

    The Neutron Imaging System at the National Ignition Facility is used to observe the primary ∼14 MeV neutrons from the hotspot and down-scattered neutrons (6-12 MeV) from the assembled shell. Due to the strong spatial dependence of the primary neutron fluence through the dense shell, the down-scattered image is convolved with the primary-neutron fluence much like a backlighter profile. Using a characteristic scattering angle assumption, we estimate the primary neutron fluence and compensate the down-scattered image, which reveals information about asymmetry that is otherwise difficult to extract without invoking complicated models.

  17. Evaluating UV-C LED disinfection performance and ...

    EPA Pesticide Factsheets

    This study evaluated ultraviolet (UV) light emitting diodes (LEDs) emitting at 260 nm, 280 nm, and the combination of 260|280 nm together for their efficacy at inactivating Escherichia. coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores; research included an evaluation of genomic damage. Inactivation by the LEDs was compared with the efficacy of conventional UV sources, the low-pressure (LP) and medium-pressure (MP) mercury vapor lamps. The work also calculated the electrical energy per order of reduction of the microorganisms by the five UV sources.For E. coli, all five UV sources yielded similar inactivation rates. For MS2 coliphage, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was significantly more effective than the LP UV and UVC LED sources. When considering electrical energy per order of reduction, the LP UV lamp was the most efficient for E. coli and MS2, and the MPUV and LPUV were equally efficient for HAdV2 and B. pumilus spores. Among the UVC LEDs, the 280 nm LED unit required the least energy per log reduction of E. coli and HAdV2. The 280 nm and 260|280 nm LED units were equally efficient per log reduction of B. pumilus spores, and the 260 nm LED unit required the lowest energy per order of reduction of MS2 coliphage. The combination of the 260 nm and 280 nm UV LED wavelengths was also evaluated for potential synergistic effects. No dual-wavelength synergy was detected for inactivation of

  18. Biological Research in Canisters (BRIC) - Light Emitting Diode (LED)

    NASA Technical Reports Server (NTRS)

    Levine, Howard G.; Caron, Allison

    2016-01-01

    The Biological Research in Canisters - LED (BRIC-LED) is a biological research system that is being designed to complement the capabilities of the existing BRIC-Petri Dish Fixation Unit (PDFU) for the Space Life and Physical Sciences (SLPS) Program. A diverse range of organisms can be supported, including plant seedlings, callus cultures, Caenorhabditis elegans, microbes, and others. In the event of a launch scrub, the entire assembly can be replaced with an identical back-up unit containing freshly loaded specimens.

  19. Advances in light-curing units: four generations of LED lights and clinical implications for optimizing their use: Part 2. From present to future.

    PubMed

    Shortall, Adrian C; Palin, Will M; Jacquot, Bruno; Pelissier, Bruno

    2012-01-01

    The first part of this series of two described the history of light curing in dentistry and developments in LED lights since their introduction over 20 years ago. Current second- and third-generation LED light units have progressively replaced their halogen lamp predecessors because of their inherent advantages. The background to this, together with the clinical issues relating to light curing and the possible solutions, are outlined in the second part of this article. Finally, the innovative features of what may be seen as the first of a new fourth-generation of LED lights are described and guidance is given for the practitioner on what factors to consider when seeking to purchase a new LED light activation unit. Adequate curing in depth is fundamental to clinical success with any light-activated restoration. To achieve this goal predictably, an appropriate light source needs to be combined with materials knowledge, requisite clinical skills and attention to detail throughout the entire restoration process. As dentists increasingly use light-cured direct composites to restore large posterior restorations they need to appreciate the issues central to effective and efficient light curing and to know what to look for when seeking to purchase a new light-curing unit.

  20. The lived experiences of autonomous Angolan midwives working in midwifery-led, maternity units.

    PubMed

    Pettersson, K O; Svensson, M L; Christensson, K

    2001-06-01

    to describe the lived experiences of autonomous midwives working in Angolan midwifery-led maternity units. a qualitative approach using semi-structured, audiotaped interviews, in Portugese. Data were analysed in a six-step process. three midwifery-led maternity units in the most densely populated suburbs in the capital of Angola, Luanda. The average number of deliveries per unit was 2500 per year. 11 midwives from the three maternity units. four main areas emerged: society/culture, significant others, personal self and professional self. Sub-areas, concepts and supporting statements were defined in each area. the midwives served within a population living in rough circumstances but which maintained strong traditional roots. The midwives did not support homebirths, but did assist when needed. The midwives described their professional role as a 'calling', which was very independent. Cure, was considered more important than care, and strong emotions were expressed when discussing cases of failure. The partograph was viewed as an important instrument and continuous learning as crucial in their role as autonomous midwives. the model of a midwifery-led delivery unit described in this study may be used in other countries facing the same problems as Angola. Difficulties concerning transfer should be seriously considered as well as adequate education for the midwives. A pre-requisite in order for peripheral maternity units to have any impact on maternal morbidity and mortality, is a well-organised first-referral level. Copyright 2001 Harcourt Publishers Ltd.

  1. Observation of a Hydrodynamically Driven, Radiative Precursor Shock

    NASA Astrophysics Data System (ADS)

    Keiter, P. A.; Drake, R. P.; Perry, T. S.; Robey, H.; Remington, B. A.; Iglesias, C. A.; Turner, N.; Stone, J.; Knauer, J.

    2001-10-01

    Many astrophysical systems, such as supernova remnants and jets, produce radiative-precursor shock waves. In a radiative-precursor shock, radiation from the shock ionizes and heats the medium ahead of it. The simulation of such systems requires that one treat both the emission and the absorption of the radiation. An important goal of this effort is to produce an experiment that can be modeled by astrophysical codes without implementing laser absorption physics into an astrophysical code. We report here the first measurements of a radiative-precursor shock in such an experiment. The experimental design is based on a past experiment[1,2] that used the Nova laser facility to simulate young supernova remnants. The target consists of a 60 νm CH plastic plug followed by a 150 νm vacuum gap and 2 mm of SiO2 aerogel foam. For the experiment, the density of the components and the laser-irradiation conditions are chosen so that the driven shock will produce an observable radiative precursor. We observed the radiative-precursor by using absorption spectroscopy. By backlighting the silicate aerogel foam with a thulium backlighter, we were able to observe both the 1s-2p and 1s-3p lines. These observations will allow us to determine the temperature profile in the precursor. 1. R.P. Drake, et al, Phys. Rev. Lett. 81, 2068 (1998). 2. R.P. Drake, et al., Phys. Plasmas, 7, 2142 (2000) Work supported by the U.S. Department of Energy both directly and through the Lawrence Livermore National Laboratory

  2. Image analysis algorithms for the advanced radiographic capability (ARC) grating tilt sensor at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Roberts, Randy S.; Bliss, Erlan S.; Rushford, Michael C.; Halpin, John M.; Awwal, Abdul A. S.; Leach, Richard R.

    2014-09-01

    The Advance Radiographic Capability (ARC) at the National Ignition Facility (NIF) is a laser system designed to produce a sequence of short pulses used to backlight imploding fuel capsules. Laser pulses from a short-pulse oscillator are dispersed in wavelength into long, low-power pulses, injected in the NIF main laser for amplification, and then compressed into high-power pulses before being directed into the NIF target chamber. In the target chamber, the laser pulses hit targets which produce x-rays used to backlight imploding fuel capsules. Compression of the ARC laser pulses is accomplished with a set of precision-surveyed optical gratings mounted inside of vacuum vessels. The tilt of each grating is monitored by a measurement system consisting of a laser diode, camera and crosshair, all mounted in a pedestal outside of the vacuum vessel, and a mirror mounted on the back of a grating inside the vacuum vessel. The crosshair is mounted in front of the camera, and a diffraction pattern is formed when illuminated with the laser diode beam reflected from the mirror. This diffraction pattern contains information related to relative movements between the grating and the pedestal. Image analysis algorithms have been developed to determine the relative movements between the gratings and pedestal. In the paper we elaborate on features in the diffraction pattern, and describe the image analysis algorithms used to monitor grating tilt changes. Experimental results are provided which indicate the high degree of sensitivity provided by the tilt sensor and image analysis algorithms.

  3. Recognition and Matching of Clustered Mature Litchi Fruits Using Binocular Charge-Coupled Device (CCD) Color Cameras

    PubMed Central

    Wang, Chenglin; Tang, Yunchao; Zou, Xiangjun; Luo, Lufeng; Chen, Xiong

    2017-01-01

    Recognition and matching of litchi fruits are critical steps for litchi harvesting robots to successfully grasp litchi. However, due to the randomness of litchi growth, such as clustered growth with uncertain number of fruits and random occlusion by leaves, branches and other fruits, the recognition and matching of the fruit become a challenge. Therefore, this study firstly defined mature litchi fruit as three clustered categories. Then an approach for recognition and matching of clustered mature litchi fruit was developed based on litchi color images acquired by binocular charge-coupled device (CCD) color cameras. The approach mainly included three steps: (1) calibration of binocular color cameras and litchi image acquisition; (2) segmentation of litchi fruits using four kinds of supervised classifiers, and recognition of the pre-defined categories of clustered litchi fruit using a pixel threshold method; and (3) matching the recognized clustered fruit using a geometric center-based matching method. The experimental results showed that the proposed recognition method could be robust against the influences of varying illumination and occlusion conditions, and precisely recognize clustered litchi fruit. In the tested 432 clustered litchi fruits, the highest and lowest average recognition rates were 94.17% and 92.00% under sunny back-lighting and partial occlusion, and sunny front-lighting and non-occlusion conditions, respectively. From 50 pairs of tested images, the highest and lowest matching success rates were 97.37% and 91.96% under sunny back-lighting and non-occlusion, and sunny front-lighting and partial occlusion conditions, respectively. PMID:29112177

  4. LLE 1994 annual report, October 1993--September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-01-01

    This is the 1994 annual report for the University of Rochester, Laboratory for Laser Energetics. The report is presented as a series of research type reports. The titles emphasize the breadth of work carried out. They are: stability analysis of unsteady ablation fronts; characterization of laser-produced plasma density profiles using grid image refractometry; transport and sound waves in plasmas with light and heavy ions; three-halves-harmonic radiation from long-scale-length plasmas revisited; OMEGA upgrade status report; target imaging and backlighting diagnosis; effect of electron collisions on ion-acoustic waves and heat flow; particle-in-cell code simulations of the interaction of gaussian ultrashort laser pulsesmore » with targets of varying initial scale lengths; characterization of thick cryogenic fuel layers: compensation for the lens effect using convergent beam interferometry; compact, multijoule-output, Nd:Glass, large-aperture ring amplifier; atomic force microscopy observation of water-induced morphological changes in Y{sub 2}O{sub 3} monolayer coatings; observation of longitudinal acceleration of electrons born in a high-intensity laser focus; spatial intensity nonuniformities of an OMEGA beam due to nonlinear beam propagation; calculated X-ray backlighting images of mixed imploded targets; evaluation of cosmic rays for use in the monitoring of the MEDUSA scintillator-photomultiplier diagnostic array; highly efficient second-harmonic generation of ultra-intense Nd:Glass laser pulses multiple cutoff wave numbers of the ablative Rayleigh-Taylor instability; ultrafast, all-silicon light modulator; angular dependence of the stimulated Brillouin scattering in homogeneous plasma; femtosecond excited-state dynamics of a conjugated ladder polymer.« less

  5. Spectral content of buried Ag foils at 10{sup 16} W/cm{sup 2} laser illumination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huntington, C. M., E-mail: huntington4@llnl.gov; Maddox, B. R.; Park, H.-S.

    2014-11-15

    Sources of 5–12 keV thermal Heα x-rays are readily generated by laser irradiation of mid-Z foils at intensities >10{sup 14} W/cm{sup 2}, and are widely used as probes for inertial confinement fusion and high-energy-density experiments. Higher energy 17–50 keV x-ray sources are efficiently produced from “cold” Kα emission using short pulse, petawatt lasers at intensities >10{sup 18} W/cm{sup 2} [H.-S. Park, B. R. Maddox et al., “High-resolution 17–75 keV backlighters for high energy density experiments,” Phys. Plasmas 15(7), 072705 (2008); B. R. Maddox, H. S. Park, B. A. Remington et al., “Absolute measurements of x-ray backlighter sources at energies abovemore » 10 keV,” Phys. Plasmas 18(5), 056709 (2011)]. However, when long pulse (>1 ns) lasers are used with Z > 30 elements, the spectrum contains contributions from both K shell transitions and from ionized atomic states. Here we show that by sandwiching a silver foil between layers of high-density carbon, the ratio of Kα:Heα in the x-ray spectrum is significant increased over directly illuminated Ag foils, with narrower lines from K-shell transitions. Additionally, the emission volume is more localized for the sandwiched target, producing a more planar x-ray sheet. This technique may be useful for generating probes requiring spectral purity and a limited spatial extent, for example, in incoherent x-ray Thomson scattering experiments.« less

  6. Measurement of inflight shell areal density near peak velocity using a self backlighting technique

    NASA Astrophysics Data System (ADS)

    Pickworth, L. A.; Hammel, B. A.; Smalyuk, V. A.; MacPhee, A. G.; Scott, H. A.; Robey, H. F.; Landen, O. L.; Barrios, M. A.; Regan, S. P.; Schneider, M. B.; Hoppe, M., Jr.; Kohut, T.; Holunga, D.; Walters, C.; Haid, B.; Dayton, M.

    2016-05-01

    The growth of perturbations in inertial confinement fusion (ICF) capsules can lead to significant variation of inflight shell areal density (ρR), ultimately resulting in poor compression and ablator material mixing into the hotspot. As the capsule is accelerated inward, the perturbation growth results from the initial shock-transit through the shell and then amplification by Rayleigh-Taylor as the shell accelerates inwards. Measurements of ρR perturbations near peak implosion velocity (PV) are essential to our understanding of ICF implosions because they reflect the integrity of the capsule, after the inward acceleration growth is complete, of the actual shell perturbations including native capsule surface roughness and “isolated defects”. Quantitative measurements of shell-ρR perturbations in capsules near PV are challenging, requiring a new method with which to radiograph the shell. An innovative method, utilized in this paper, is to use the self-emission from the hotspot to “self- backlight” the shell inflight. However, with nominal capsule fills there is insufficient self-emission for this method until the capsule nears peak compression (PC). We produce a sufficiently bright continuum self-emission backlighter through the addition of a high-Z gas (∼ 1% Ar) to the capsule fill. This provides a significant (∼10x) increase in emission at hυ∼8 keV over nominal fills. “Self backlit” radiographs are obtained for times when the shock is rebounding from the capsule center, expanding out to meet the incoming shell, providing a means to sample the capsule optical density though only one side, as it converges through PV.

  7. Customize Learning with Student-Generated Guiding Questions

    ERIC Educational Resources Information Center

    Virgin, Robb

    2015-01-01

    Outlined in this article is the three-year journey of a middle school social studies department that led to a shift from teacher-led units of instruction (e.g., Reconstruction) to units that used student-generated questions (e.g., What was life like for former slaves?, How did Southerners' lifestyles change?, Did the North and South cooperate?,…

  8. Light-Emitting Diodes: Exploration of Underlying Physics

    ERIC Educational Resources Information Center

    Etkina, Eugenia; Planinšic, Gorazd

    2014-01-01

    This paper is the second in the series of LED-dedicated papers that have a goal to systematically investigate the use of LEDs in a general physics course. The first paper, published in the February 2014 issue, provided an overview of the course units where LEDs can be used and suggested three different ways of utilizing LEDs in an introductory…

  9. Magnesium-based photocathodes for triggering back-lighted thyratrons

    NASA Astrophysics Data System (ADS)

    Sozer, Esin B.

    This dissertation presents experimental studies of application of magnesium-based photocathodes to optically triggered pseudospark switches, called back-lighted thyratrons (BLTs). Magnesium was chosen as a low work function metal photocathode for its potential to increase triggering performance of the switch with a higher photoemission performance than traditional BLT cathodes. Improvement in triggering performance of plasma switches is of interest for device development of compact pulsed power systems where the size of switching units can limit the overall size and the mobility of the system. Experiments were conducted on photoemission performance of photocathode candidates under BLT-relevant conditions; and delay and jitter performance of a BLT with photocathode candidates with changing helium pressure and switch voltages. A review of photocathode literature showed that Mg and Cu are the most promising candidates for increasing the photoemission during the triggering of BLTs. As a commonly used BLT cathode in the switch literature, Mo was chosen together with Mg and Cu to be tested under BLT-relevant pressure and field conditions. Quantum efficiency measurements of high-purity foils of Mg, Cu and Mo showed a superior performance of Mg and Cu over Mo. Mg had the highest quantum efficiency of 1.5 x 10-5 among all three materials. After photoemission measurements in a test bed were concluded, testing of these cathodes for their switching performance was done in two stages. First, an unfocused UV laser beam (8.5 x 106 W/cm 2) with a wavelength of 266 nm was used for delay measurements of a BLT with Mg, Cu and Mo-based cathodes. Mg-based cathodes showed at least a thirty-fold reduction in delay and jitter compared to Cu-based and at least an eighty-fold reduction in delay and jitter compared to Mo-based cathodes at any given helium pressure and switch voltage pair. Subsequently, a partial focusing of the same light source was utilized (7.4 x 107W/cm 2) for delay measurements of a BLT with copper electrodes at constant switch voltage and changing helium pressure before and after integration of a Mg foil. These measurements showed an order of magnitude shorter delay and jitter throughout the pressure range when the high-purity Mg-foil was present at the switch cathode. Theoretical estimations of electron emission from the cathode during the triggering suggested that the main mechanism responsible for the observed change in delay and jitter was the increased photoemission due to the lower work function of the Mg cathode and that the effect of temperature on triggering is negligible. SEM images of the high-purity Mg foil integrated at the BLT cathode for 106 shots showed signs of melting around the bore hole. No degradation of the switch performance was observed for the duration of 10 6 shots. In conclusion, magnesium-based cathodes for BLTs showed an important potential for small triggering units for optical triggering, especially when the intensity of the optical source is limited. A future work involving plasma simulations is suggested for assessing potential of different cathode/optical source pairs for triggering BLTs.

  10. Are nurse-led chemotherapy clinics really nurse-led? An ethnographic study.

    PubMed

    Farrell, Carole; Walshe, Catherine; Molassiotis, Alex

    2017-04-01

    The number of patients requiring ambulatory chemotherapy is increasing year on year, creating problems with capacity in outpatient clinics and chemotherapy units. Although nurse-led chemotherapy clinics have been set up to address this, there is a lack of evaluation of their effectiveness. Despite a rapid expansion in the development of nursing roles and responsibilities in oncology, there is little understanding of the operational aspects of nurses' roles in nurse-led clinics. To explore nurses' roles within nurse-led chemotherapy clinics. A focused ethnographic study of nurses' roles in nurse-led chemotherapy clinics, including semi-structured interviews with nurses. Four chemotherapy units/cancer centres in the UK PARTICIPANTS: Purposive sampling was used to select four cancer centres/units in different geographical areas within the UK operating nurse-led chemotherapy clinics. Participants were 13 nurses working within nurse-led chemotherapy clinics at the chosen locations. Non-participant observation of nurse-led chemotherapy clinics, semi-structured interviews with nurse participants, review of clinic protocols and associated documentation. 61 nurse-patient consultations were observed with 13 nurses; of these 13, interviews were conducted with 11 nurses. Despite similarities in clinical skills training and prescribing, there were great disparities between clinics run by chemotherapy nurses and those run by advanced nurse practitioners. This included the number of patients seen within each clinic, operational aspects, nurses' autonomy, scope of practice and clinical decision-making abilities. The differences highlighted four different levels of nurse-led chemotherapy clinics, based on nurses' autonomy and scope of clinical practice. However, this was heavily influenced by medical consultants. Several nurses perceived they were undertaking holistic assessments, however they were using medical models/consultation styles, indicating medicalization of nurses' roles. Four different levels of nurse-led chemotherapy clinics were identified, illustrating disparities in nurses' roles. Although clinics are run by nurses they are often controlled by medical consultants, which can reduce nurses' autonomy and negatively impact on patient care. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Mitigation of hard x-ray background in backlit pinhole imagers

    DOE PAGES

    Fein, J. R.; Keiter, P. A.; Holloway, J. P.; ...

    2016-09-16

    Experiments were performed to mitigate the hard x-ray background commonly observed in backlit pinhole imagers. The material of the scaffold holding the primary backlighter foil was varied to reduce the laser-plasma instabilities responsible for hot electrons and resulting hard x-ray background. Radiographic measurements with image plates showed a factor of >25 decrease in x-rays between 30 and 67 keV when going from a plastic to Al or V scaffold. Here, a potential design using V scaffold offers a signal-to-background ratio of 6:1, a factor of 2 greater than using the bare plastic scaffold.

  12. On the prospects of application and development of solid-state photomultipliers for the task of analog detecting of pulsed optical signals

    NASA Astrophysics Data System (ADS)

    Bogdanov, S. V.; Kolobov, N. A.; Levin, E. V.; Pozdnyakov, Y. I.; Shubin, V. E.; Shushakov, D. A.; Sitarsky, K. Yu.; Torgovnikov, R. A.

    2018-02-01

    In this paper, we analyze the influence of the crosstalk level and the dynamic range on the basic characteristics of a silicon solid-state photomultiplier and demonstrate their importance for detecting of optical signals with backlight illumination, in particular, for LIDAR application. Experimental results obtained in the study of threshold and fluctuation parameters of detectors with different levels of crosstalk and dynamic range are presented. It is shown that the detector design combining a high dynamic range with a small crosstalk gives a noticeable advantage in such applications.

  13. Comparing Smoking Cessation Outcomes in Nurse-Led and Physician-Led Primary Care Visits.

    PubMed

    Byers, Marcia A; Wright, Patricia; Tilford, John Mick; Nemeth, Lynne S; Matthews, Ellyn; Mitchell, Anita

    Smoking is a significant public health concern in the United States, yet 50% of patients do not receive recommended tobacco use screening and counseling. This project compared smoking cessation rates in newly reimbursable nurse-led wellness visits with rates in physician-led visits. Although the findings were not statistically significant, they suggested that smoking cessation is at least equivalent in patients who attend nurse-led visits compared with physician-led visits and may be higher.

  14. Enhanced light extraction from a GaN-based green light-emitting diode with hemicylindrical linear grating structure.

    PubMed

    Jin, Yuanhao; Yang, Fenglei; Li, Qunqing; Zhu, Zhendong; Zhu, Jun; Fan, Shoushan

    2012-07-02

    Significant enhancement in the light output from GaN-based green light-emitting diodes (LEDs) was achieved with a hemicylindrical grating structure on the top layer of the diodes. The grating structure was first optimized by the finite-difference time-domain (FDTD) method, which showed that the profile of the grating structure was critical for light extraction efficiency. It was found that the transmission efficiency of the 530 nm light emitted from the inside of the GaN LED increased for incidence angles between 23.58° and 60°. Such a structure was fabricated by electron-beam lithography and an etching method. The light output power from the LED was increased approximately 4.7 times compared with that from a conventional LED. The structure optimization is the key to the great increase in transmission efficiency. Furthermore, the light emitted from the edge of the LED units could be collected and extracted by the grating structures in adjacent LED units, thus enhancing the performance of the whole LED chip.

  15. Comparison of hardness of three temporary filling materials cured by two light-curing devices.

    PubMed

    Bodrumlu, E; Koçak, M M; Hazar Bodrumlu, E; Ozcan, S; Koçak, S

    2014-01-01

    Polymerization ability of light-curing devices can affect the light-cured material hardness. The purpose of the present study was to evaluate and compare the hardness of three temporary filling materials that had been light-cured by either a light emitting diode (LED) or a halogen light-curing unit. The temporary filling materials, First Fill, Voco Clip and Bioplic, were placed in wells in a Teflon plate. The 24 specimens of each material were divided into two groups (N.=12/group) for photo-activation by either of the two light-curing units. The LED or halogen device was applied for 40s to the top surface of each specimen. A Knoop hardness test was performed on the top and bottom surface of each specimen, with five measurements per specimen. The highest hardness values for both the LED and halogen treated groups were observed for First Fill and the lowest values were for Voco Clip in top and bottom surfaces. The hardness obtained for the three materials with the halogen unit were significantly higher than the values obtained with the LED unit in both surfaces (P<0.05). First Fill light-cured temporary material exhibited the highest hardness values on the top and bottom surfaces than Voco Clip and Bioplic temporary materials. The hardness of light-cured temporary filling materials can be affected by the type of light-curing unit.

  16. Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times

    PubMed Central

    Gupta, Sanjay Prasad; Shrestha, Basanta Kumar

    2018-01-01

    Purpose To determine and compare the shear bond strength (SBS) of bracket-bonding system cured with light-emitting diode (LED) and halogen-based light-curing unit at various polymerization times. Materials and methods Ninety six human maxillary premolar teeth extracted for orthodontic purpose were divided into four groups, according to the light-curing unit and exposure times used. In the halogen group, the specimens were light cured for 20 and 40 seconds. In the LED group, the specimens were light cured for 5 and 10 seconds. Stainless steel brackets were bonded with Enlight bonding system, stored in distilled water at 37°C for 24 hours and then submitted to SBS testing in a universal testing machine at a crosshead speed of 0.5 mm/minute. Adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the teeth determined by stereomicroscope at 10× magnification. Results The highest mean SBS was obtained with the halogen 40 seconds (18.27 MPa) followed by halogen 20 seconds (15.36 MPa), LED 10 seconds (14.60 MPa) and least with LED 5 seconds (12.49 MPa) group. According to analysis of variance (ANOVA) and Tukey’s multiple-comparison test, SBS of halogen 20 seconds group was not significantly different from halogen 40 seconds group, LED 5 seconds group and LED 10 seconds group, whereas halogen 40 seconds group was significantly different from LED 5 seconds and LED 10 seconds group. The method of light curing did not influence the ARI, with score 2 being predominant. Conclusion Polymerization with both halogen and LED resulted in SBS values that were clinically acceptable for orthodontic treatment in all groups. Hence, for bonding orthodontic brackets, photoactivation with halogen for 20 seconds and LED for 5 seconds is suggested. PMID:29692633

  17. Bonding to Different PEEK Compositions: The Impact of Dental Light Curing Units

    PubMed Central

    Lümkemann, Nina; Eichberger, Marlis; Stawarczyk, Bogna

    2017-01-01

    This study investigated the impact of different light curing units (LCUs) for the polymerization of adhesive system visio.link (VL) on the tensile bond strength (TBS) of different PEEK compositions. For TBS measurements, 216 PEEK specimens with varying amounts of TiO2 (PEEK/0%, PEEK/20%, PEEK/>30%) were embedded, polished, air abraded (Al2O3, 50 µm, 0.4 MPa), conditioned using VL, and polymerized using either a halogen LCU (HAL-LCU) or a LED LCU (LED-LCU) for chairside or labside application, respectively. After thermocycling (5000×, 5/55 °C), TBS was measured, and fracture types were determined. Data was analyzed using a 2-way ANOVA followed by Tukey–HSD, Kruskal–Wallis H and Mann–Whitney U tests as well as a Chi2-test and a Ciba–Geigy table (p < 0.05). Globally, the light curing units, followed by PEEK composition, was shown to have the highest impact on TBS. The HAL-LCUs, compared to the LED-LCUs, resulted in a higher TBS for all PEEK compositions—without significant differences between chairside and labside units. Regarding the different PEEK compositions, PEEK/20%, compared to PEEK/0%, resulted in a higher TBS when both, HAL-LCUs or LED-LCUs were used for labside application. In comparison with PEEK/>30%, PEEK/20% resulted in a higher TBS after using HAL-LCU for labside application. No significant differences were found between PEEK/0% and PEEK/>30%. HAL-LCU with PEEK/20% for labside application showed a higher TBS than HAL-LCU with PEEK/20% for chairside application, whereas LED-LCU with PEEK/>30% for chairside application showed a higher TBS than LED-LCU with PEEK/>30% for labside application. PMID:28772427

  18. Modern high powered led curing lights and their effect on pulp chamber temperature of bulk and incrementally cured composite resin.

    PubMed

    Oberholzer, T G; Makofane, M E; du Preez, I C; George, R

    2012-06-01

    Pulpal temperature changes induced by modern high powered light emitting diodes (LEDs) are of concern when used to cure composite resins. This study showed an increase in pulp chamber temperature with an increase in power density for all light cure units (LCU) when used to bulk cure composite resin. Amongst the three LEDs tested, the Elipar Freelight-2 recorded the highest temperature changes. Bulk curing recorded a significantly larger rise in pulp chamber temperature change than incrementally cured resin for all light types except for the Smartligh PS. Both the high powered LED and the conventional curing units can generate heat. Though this temperature rise may not be sufficient to cause irreversible pulpal damage, it would be safer to incrementally cure resins.

  19. Conceptual design of initial opacity experiments on the national ignition facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, R.  F.; Bailey, J.  E.; Craxton, R.  S.

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative–convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperaturesmore » $${\\geqslant}150$$ eV and electron densities$${\\geqslant}7\\times 10^{21}~\\text{cm}^{-3}$$. The iron will be probed using continuum X-rays emitted in a$${\\sim}200$$ ps,$${\\sim}200~\\unicode[STIX]{x03BC}\\text{m}$$diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design,$2/3$$of the NIF beams deliver 500 kJ to the$${\\sim}6$$ mm diameter hohlraum, and the remaining$$1/3$directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.« less

  20. Cryogenic characterization of LEDs for space application

    NASA Astrophysics Data System (ADS)

    Carron, Jérôme; Philippon, Anne; How, Lip Sun; Delbergue, Audrey; Hassanzadeh, Sahar; Cillierre, David; Danto, Pascale; Boutillier, Mathieu

    2017-09-01

    In the frame of EUCLID project, the Calibration Unit of the VIS (VISible Imager) instrument must provide an accurate and well characterized light source for in-flight instrument calibration without noise when it is switched off. The Calibration Unit consists of a set of LEDs emitting at various wavelengths in the visible towards an integrating sphere. The sphere's output provides a uniform illumination over the entire focal plane. Nine references of LEDs from different manufacturers were selected, screened and qualified under cryogenic conditions. Testing this large quantity of samples led to the implementation of automated testing equipment with complete in-situ monitoring of optoelectronic parameters as well as temperature and vacuum values. All the electrical and optical parameters of the LED have been monitored and recorded at ambient and cryogenic temperatures. These results have been compiled in order to show the total deviation of the LED electrical and electro-optical properties in the whole mission and to select the best suitable LED references for the mission. This qualification has demonstrated the robustness of COTS LEDs to operate at low cryogenic temperatures and in the space environment. Then 6 wavelengths were selected and submitted to an EMC sensitivity test at room and cold temperature by counting the number of photons when LEDs drivers are OFF. Characterizations were conducted in the full frequency spectrum in order to implement solutions at system level to suppress the emission of photons when the LED drivers are OFF. LEDs impedance was also characterized at room temperature and cold temperature.

  1. Engaging Direct Care Providers in Improving Infection Prevention and Control Practices Using Participatory Visual Methods.

    PubMed

    Backman, Chantal; Bruce, Natalie; Marck, Patricia; Vanderloo, Saskia

    2016-01-01

    The purpose of this quality improvement project was to determine the feasibility of using provider-led participatory visual methods to scrutinize 4 hospital units' infection prevention and control practices. Methods included provider-led photo walkabouts, photo elicitation sessions, and postimprovement photo walkabouts. Nurses readily engaged in using the methods to examine and improve their units' practices and reorganize their work environment.

  2. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    NASA Astrophysics Data System (ADS)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-02-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved by 39% compared to that of the Xenon flash lamp based unit, due to the LEDs narrower emission spectrum and longer pulse width. Key parameters of the LED system are discussed to further optimize the signal-to-noise ratio and signal-to-background, and hence the sensitivity of the instrument.

  3. Evaluation of a Peer-Led Drug Abuse Risk Reduction Project for Runaway/Homeless Youths.

    ERIC Educational Resources Information Center

    Fors, Stuart W.; Jarvis, Sara

    1995-01-01

    Evaluates the Drug Prevention in Youth risk reduction program that was implemented in shelters for runaway/homeless youths in the southeastern United States. An evaluation strategy was developed allowing for comparisons between peer-led, adult-led and nonintervention groups. Well-trained and motivated peer/near-peer leaders made particularly…

  4. Marginal integrity of resin composite restorations restored with PPD initiatorcontaining resin composite cured by QTH, monowave and polywave LED units.

    PubMed

    Bortolotto, Tissiana; Betancourt, Francisco; Krejci, Ivo

    2016-12-01

    This study evaluated the influence of curing devices on marginal adaptation of cavities restored with self-etching adhesive containing CQ and PPD initiators and hybrid composite. Twenty-four class V (3 groups, n=8) with margins located on enamel and dentin were restored with Clearfil S3 Bond and Clearfil APX PLT, light-cured with a monowave LED, multiwave LED and halogen light-curing unit (LCU). Marginal adaptation was evaluated with SEM before/after thermo-mechanical loading (TML). On enamel, significantly lower % continuous margins (74.5±12.6) were found in group cured by multiwave LED when compared to monowave LED (87.6±9.5) and halogen LCU (94.4±9.1). The presence of enamel and composite fractures was significantly higher in the group light-cured with multiwave LED, probably due to an increased materials' friability resulted from an improved degree of cure. The clinician should aware that due to a distinct activation of both initiators, marginal quality may be influenced on the long-term.

  5. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    PubMed

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  6. Does size matter? Animal units and animal unit months

    Treesearch

    Lamar Smith; Joe Hicks; Scott Lusk; Mike Hemmovich; Shane Green; Sarah McCord; Mike Pellant; John Mitchell; Judith Dyess; Jim Sprinkle; Amanda Gearhart; Sherm Karl; Mike Hannemann; Ken Spaeth; Jason Karl; Matt Reeves; Dave Pyke; Jordan Spaak; Andrew Brischke; Del Despain; Matt Phillippi; Dave Weixelmann; Alan Bass; Jessie Page; Lori Metz; David Toledo; Emily Kachergis

    2017-01-01

    The concepts of animal units, animal unit months, and animal unit equivalents have long been used as standards for range management planning, estimating stocking rates, reporting actual use, assessing grazing fees, ranch appraisal, and other purposes. Increasing size of cattle on rangelands has led some to suggest that the definition of animal units and animal unit...

  7. 78 FR 23542 - Procurement List; Proposed Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-19

    ..., Programmable Flicker Pattern, Red LED, 8in Diameter, AA Battery Operated. NSN: 6230-00-NIB-0034--Kit, Safety Flare, Programmable Flicker Pattern, Red LED, 8in Diameter, Rechargeable Power Unit. Coverage: B-List...

  8. A note on the contribution of multi-photon processes to radiative opacity

    NASA Astrophysics Data System (ADS)

    Pain, Jean-Christophe

    2018-03-01

    Recently, Bailey et al. performed iron opacity measurements on the Z machine at Sandia National Laboratory in conditions close to the ones of the base of the convective zone of the Sun. Such experiments have raised questions about the physical models commonly used in opacity codes. To understand the discrepancy between experiment and theory, More et al. investigated the role of two-photon processes. In the present work we show, by simple estimate and using hydrogenic formulas, that due to the intensity of the backlight radiation seen by the sample, such processes are likely to play an important role only for highly excited states.

  9. Hunting behavior of a marine mammal beneath the antarctic fast Ice

    PubMed

    Davis; Fuiman; Williams; Collier; Hagey; Kanatous; Kohin; Horning

    1999-02-12

    The hunting behavior of a marine mammal was studied beneath the Antarctic fast ice with an animal-borne video system and data recorder. Weddell seals stalked large Antarctic cod and the smaller subice fish Pagothenia borchgrevinki, often with the under-ice surface for backlighting, which implies that vision is important for hunting. They approached to within centimeters of cod without startling the fish. Seals flushed P. borchgrevinki by blowing air into subice crevices or pursued them into the platelet ice. These observations highlight the broad range of insights that are possible with simultaneous recordings of video, audio, three-dimensional dive paths, and locomotor effort.

  10. Microgravity

    NASA Image and Video Library

    1991-04-03

    The USML-1 Glovebox (GBX) is a multi-user facility supporting 16 experiments in fluid dynamics, combustion sciences, crystal growth, and technology demonstration. The GBX has an enclosed working space which minimizes the contamination risks to both Spacelab and experiment samples. The GBX supports four charge-coupled device (CCD) cameras (two of which may be operated simultaneously) with three black-and-white and three color camera CCD heads available. The GBX also has a backlight panel, a 35 mm camera, and a stereomicroscope that offers high-magnification viewing of experiment samples. Video data can also be downlinked in real-time. The GBX also provides electrical power for experiment hardware, a time-temperature display, and cleaning supplies.

  11. Microgravity

    NASA Image and Video Library

    1995-08-29

    The USML-1 Glovebox (GBX) is a multi-user facility supporting 16 experiments in fluid dynamics, combustion sciences, crystal growth, and technology demonstration. The GBX has an enclosed working space which minimizes the contamination risks to both Spacelab and experiment samples. The GBX supports four charge-coupled device (CCD) cameras (two of which may be operated simultaneously) with three black-and-white and three color camera CCD heads available. The GBX also has a backlight panel, a 35 mm camera, and a stereomicroscope that offers high-magnification viewing of experiment samples. Video data can also be downlinked in real-time. The GBX also provides electrical power for experiment hardware, a time-temperature display, and cleaning supplies.

  12. Recent progress of carbon nanotube field emitters and their application.

    PubMed

    Seelaboyina, Raghunandan; Choi, Wonbong

    2007-01-01

    The potential of utilizing carbon nanotube field emission properties is an attractive feature for future vacuum electronic devices including: high power microwave, miniature x-ray, backlight for liquid crystal displays and flat panel displays. Their high emission current, nano scale geometry, chemical inertness and low threshold voltage for emission are attractive features for the field emission applications. In this paper we review the recent developments of carbon nanotube field emitters and their device applications. We also discuss the latest results on field emission current amplification achieved with an electron multiplier microchannel plate, and emission performance of multistage field emitter based on oxide nanowire operated in poor vacuum.

  13. Fluence-compensated down-scattered neutron imaging using the neutron imaging system at the National Ignition Facility.

    PubMed

    Casey, D T; Volegov, P L; Merrill, F E; Munro, D H; Grim, G P; Landen, O L; Spears, B K; Fittinghoff, D N; Field, J E; Smalyuk, V A

    2016-11-01

    The Neutron Imaging System at the National Ignition Facility is used to observe the primary ∼14 MeV neutrons from the hotspot and down-scattered neutrons (6-12 MeV) from the assembled shell. Due to the strong spatial dependence of the primary neutron fluence through the dense shell, the down-scattered image is convolved with the primary-neutron fluence much like a backlighter profile. Using a characteristic scattering angle assumption, we estimate the primary neutron fluence and compensate the down-scattered image, which reveals information about asymmetry that is otherwise difficult to extract without invoking complicated models.

  14. All Those Who Remained: The American-Led Guerillas in the Philippines, 1942-1945

    DTIC Science & Technology

    2014-12-04

    United States Army School of Advanced Military Studies United States Army Command and General Staff College Fort Leavenworth, Kansas 2014-02...SPONSOR/MONITOR’S ACRONYM(S) Command and General Staff College CGSC 731 McClellan Avenue Fort Leavenworth, KS 66027-1350 11. SPONSOR/MONITOR’S...Luzon through all phases of the campaign. This monograph evaluates the effectiveness of these American-led guerilla groups in supporting the US

  15. Student-Led Services in a Hospital Aged Care Temporary Stay Unit: Sustaining Student Placement Capacity and Physiotherapy Service Provisions

    ERIC Educational Resources Information Center

    Nicole, Madelyn; Fairbrother, Michele; Nagarajan, Srivalli Vilapakkam; Blackford, Julia; Sheepway, Lyndal; Penman, Merrolee; McAllister, Lindy

    2015-01-01

    Through a collaborative university-hospital partnership, a student-led service model (SLS-model) was implemented to increase student placement capacity within a physiotherapy department of a 150 bed Sydney hospital. This study investigates the perceived barriers and enablers to increasing student placement capacity through student-led services…

  16. Patient-led versus physician-led titration of insulin glargine in patients with uncontrolled type 2 diabetes: a randomized multinational ATLAS study.

    PubMed

    Garg, Satish K; Admane, Karim; Freemantle, Nick; Odawara, Masato; Pan, Chang-Yu; Misra, Anoop; Jarek-Martynowa, Iwona R; Abbas-Raza, Syed; Mirasol, Roberto C; Perfetti, Riccardo

    2015-02-01

    Self-adjustment of insulin dose is commonly practiced in Western patients with type 2 diabetes but is usually not performed in Asian patients. This multinational, 24-week, randomized study compared patient-led with physician-led titration of once-daily insulin glargine in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering agents. Patient-led (n = 275) or physician-led (n = 277) subjects followed the same dose-titration algorithm guided by self-monitored fasting blood glucose (FBG; target, 110 mg/dL [6.1 mmol/L]). The primary endpoint was change in mean glycated hemoglobin (HbA1c) at week 24 in the patient-led versus physician-led titration groups. Patient-led titration resulted in a significantly higher drop in HbA1c value at 24 weeks when compared with physician-led titration (-1.40% vs. -1.25%; mean difference, -0.15; 95% confidence interval, -0.29 to 0.00; P = .043). Mean decrease in FBG was greatest in the patient-led group (-2.85 mmol/L vs. -2.48 mmol/L; P = .001). The improvements in HbA1c and FBG were consistent across countries, with similar improvements in treatment satisfaction in both groups. Mean daily insulin dose was higher in the patient-led group (28.9 units vs. 22.2 units; P<.001). Target HbA1c of <7.0% without severe hypoglycemia was achieved in 40.0% and 32.9% in the patient-led and physician-led groups, respectively (P = .086). Severe hypoglycemia was not different in the 2 groups (0.7%), with an increase in nocturnal and symptomatic hypoglycemia in the patient-led arm. Patient-led insulin glargine titration achieved near-target blood glucose levels in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering drugs, demonstrating that Asian patients can self-uptitrate insulin dose effectively when guided.

  17. Midwives' experiences of facilitating normal birth in an obstetric-led unit: a feminist perspective.

    PubMed

    Keating, Annette; Fleming, Valerie E M

    2009-10-01

    to explore midwives' experiences of facilitating normal birth in an obstetric-led unit. a feminist approach using semi-structured interviews focusing on midwives' perceptions of normal birth and their ability to facilitate this birth option in an obstetric-led unit. Ireland. a purposeful sample of 10 midwives with 6-30 years of midwifery experience. All participants had worked for a minimum of 6 years in a labour ward setting, and had been in their current setting for the previous 2 years. the midwives' narratives related to the following four concepts of patriarchy: 'hierarchical thinking', 'power and prestige', 'a logic of domination' and 'either/or thinking' (dualisms). Two themes, 'hierarchical thinking' and 'either/or thinking', (dualisms) along with their subthemes are presented in this paper. this study identified some of the reasons why midwives find it difficult to facilitate normal birth in an obstetric unit setting, and identified a need for further research in this area. Midwifery education and supportive management structures are required if midwives are to become confident practitioners of normal birth.

  18. Polychromatic SSVEP stimuli with subtle flickering adapted to brain-display interactions

    NASA Astrophysics Data System (ADS)

    Chien, Yu-Yi; Lin, Fang-Cheng; Zao, John K.; Chou, Ching-Chi; Huang, Yi-Pai; Kuo, Heng-Yuan; Wang, Yijun; Jung, Tzyy-Ping; Shieh, Han-Ping D.

    2017-02-01

    Objective. Interactive displays armed with natural user interfaces (NUIs) will likely lead the next breakthrough in consumer electronics, and brain-computer interfaces (BCIs) are often regarded as the ultimate NUI-enabling machines to respond to human emotions and mental states. Steady-state visual evoked potentials (SSVEPs) are a commonly used BCI modality due to the ease of detection and high information transfer rates. However, the presence of flickering stimuli may cause user discomfort and can even induce migraines and seizures. With the aim of designing visual stimuli that can be embedded into video images, this study developed a novel approach to induce detectable SSVEPs using a composition of red/green/blue flickering lights. Approach. Based on the opponent theory of colour vision, this study used 32 Hz/40 Hz rectangular red-green or red-blue LED light pulses with a 50% duty cycle, balanced/equal luminance and 0°/180° phase shifts as the stimulating light sources and tested their efficacy in producing SSVEP responses with high signal-to-noise ratios (SNRs) while reducing the perceived flickering sensation. Main results. The empirical results from ten healthy subjects showed that dual-colour lights flickering at 32 Hz/40 Hz with a 50% duty cycle and 180° phase shift achieved a greater than 90% detection accuracy with little or no flickering sensation. Significance. As a first step in developing an embedded SSVEP stimulus in commercial displays, this study provides a foundation for developing a combination of three primary colour flickering backlights with adjustable luminance proportions to create a subtle flickering polychromatic light that can elicit SSVEPs at the basic flickering frequency.

  19. Implementation of a Nurse-Led Family Meeting in a Neuroscience Intensive Care Unit.

    PubMed

    Wu, Huixin; Ren, Dianxu; Zinsmeister, Glenn R; Zewe, Gretchen E; Tuite, Patricia K

    2016-01-01

    The aims of this study were to develop, implement, and evaluate the impact of early intensive care unit (ICU) nurse-led family meetings on nurse-family communication, family decision making, and satisfaction of family members. Intensive care unit nurses are in an ideal position to meet family needs, and family members may cope better with the crisis of an ICU admission if consistent honest information is provided by nurses; however, there are no early ICU family meetings led by bedside nurses. This quality improvement project was implemented in a 10-bed neuroscience ICU over a 3-month period. A convenience sample of 23 nurses participated in the project. Following development of a communication protocol to facilitate nurse-led meetings, the nurses received education and then implemented the protocol. Thirty-one family members participated in the project. Family members were surveyed before and after the meetings. Mean meeting time was 26 (SD, 14) minutes. Following implementation of the meetings, findings demonstrated that families felt that communication improved (P = .02 and P = .008), they had appropriate information for decision making allowing them to feel in control (P = .002), and there was an increase in family satisfaction (P = .001). Early ICU nurse-led family meetings were feasible, improved communication between ICU nurses and family members, facilitated decision making in ICU families, and increased satisfaction of family members.

  20. LED characterization for development of on-board calibration unit of CCD-based advanced wide-field sensor camera of Resourcesat-2A

    NASA Astrophysics Data System (ADS)

    Chatterjee, Abhijit; Verma, Anurag

    2016-05-01

    The Advanced Wide Field Sensor (AWiFS) camera caters to high temporal resolution requirement of Resourcesat-2A mission with repeativity of 5 days. The AWiFS camera consists of four spectral bands, three in the visible and near IR and one in the short wave infrared. The imaging concept in VNIR bands is based on push broom scanning that uses linear array silicon charge coupled device (CCD) based Focal Plane Array (FPA). On-Board Calibration unit for these CCD based FPAs is used to monitor any degradation in FPA during entire mission life. Four LEDs are operated in constant current mode and 16 different light intensity levels are generated by electronically changing exposure of CCD throughout the calibration cycle. This paper describes experimental setup and characterization results of various flight model visible LEDs (λP=650nm) for development of On-Board Calibration unit of Advanced Wide Field Sensor (AWiFS) camera of RESOURCESAT-2A. Various LED configurations have been studied to meet dynamic range coverage of 6000 pixels silicon CCD based focal plane array from 20% to 60% of saturation during night pass of the satellite to identify degradation of detector elements. The paper also explains comparison of simulation and experimental results of CCD output profile at different LED combinations in constant current mode.

  1. A brief history of LED photopolymerization.

    PubMed

    Jandt, Klaus D; Mills, Robin W

    2013-06-01

    The majority of modern resin-based oral restorative biomaterials are cured via photopolymerization processes. A variety of light sources are available for this light curing of dental materials, such as composites or fissure sealants. Quartz-tungsten-halogen (QTH) light curing units (LCUs) have dominated light curing of dental materials for decades and are now almost entirely replaced by modern light emitting diode light curing units (LED LCUs). Exactly 50 years ago, visible LEDs were invented. Nevertheless, it was not before the 1990s that LEDs were seriously considered by scientists or manufactures of commercial LCUs as light sources to photopolymerize dental composites and other dental materials. The objective of this review paper is to give an overview of the scientific development and state-of-the-art of LED photopolymerization of oral biomaterials. The materials science of LED LCU devices and dental materials photopolymerized with LED LCU, as well as advantages and limits of LED photopolymerization of oral biomaterials, are discussed. This is mainly based on a review of the most frequently cited scientific papers in international peer reviewed journals. The developments of commercial LED LCUs as well as aspects of their clinical use are considered in this review. The development of LED LCUs has progressed in steps and was made possible by (i) the invention of visible light emitting diodes 50 years ago; (ii) the introduction of high brightness blue light emitting GaN LEDs in 1994; and (iii) the creation of the first blue LED LCUs for the photopolymerization of oral biomaterials. The proof of concept of LED LCUs had to be demonstrated by the satisfactory performance of resin based restorative dental materials photopolymerized by these devices, before LED photopolymerization was generally accepted. Hallmarks of LED LCUs include a unique light emission spectrum, high curing efficiency, long life, low energy consumption and compact device form factor. By understanding the physical principles of LEDs, the development of LED LCUs, their strengths and limitations and the specific benefits of LED photopolymerization will be better appreciated. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Combustion Power Unit--400: CPU-400.

    ERIC Educational Resources Information Center

    Combustion Power Co., Palo Alto, CA.

    Aerospace technology may have led to a unique basic unit for processing solid wastes and controlling pollution. The Combustion Power Unit--400 (CPU-400) is designed as a turboelectric generator plant that will use municipal solid wastes as fuel. The baseline configuration is a modular unit that is designed to utilize 400 tons of refuse per day…

  3. Two-digit number comparison: Decade-unit and unit-decade produce the same compatibility effect with number words.

    PubMed

    Macizo, Pedro; Herrera, Amparo

    2010-03-01

    This study explored the processing of 2-digit number words by examining the unit-decade compatibility effect in Spanish. Participants were required to choose the larger of 2-digit number words presented in verbal notation. In compatible trials the decade and unit comparisons led to the same response (e.g., 53-68) while in incompatible trials the decade and unit comparisons led to different responses (e.g., 59-74). Participants were slower on compatible trials as compared to incompatible trials. In Experiments 2 and 3, we evaluated whether the reverse compatibility effect in Spanish was only due to a pure left-to-right encoding which favours the decade processing in this language (decade-unit order). When participants processed 2-digit number words presented in reverse form (in the unit-decade order), the same reverse compatibility effect was found. This pattern of results suggests that participants have learnt a language-dependent process for analysing written numbers which is used irrespective of the specific arrangement of units and decades in the comparison task. 2010 APA, all rights reserved.

  4. Monochromatic radiography of high energy density physics experiments on the MAGPIE generator.

    PubMed

    Hall, G N; Burdiak, G C; Suttle, L; Stuart, N H; Swadling, G F; Lebedev, S V; Smith, R A; Patankar, S; Suzuki-Vidal, F; de Grouchy, P; Harvey-Thompson, A J; Bennett, M; Bland, S N; Pickworth, L; Skidmore, J

    2014-11-01

    A monochromatic X-ray backlighter based on Bragg reflection from a spherically bent quartz crystal has been developed for the MAGPIE pulsed power generator at Imperial College (1.4 MA, 240 ns) [I. H. Mitchell et al., Rev. Sci. Instrum. 67, 1533 (2005)]. This instrument has been used to diagnose high energy density physics experiments with 1.865 keV radiation (Silicon He-α) from a laser plasma source driven by a ∼7 J, 1 ns pulse from the Cerberus laser. The design of the diagnostic, its characterisation and performance, and initial results in which the instrument was used to radiograph a shock physics experiment on MAGPIE are discussed.

  5. Evaluation of microleakage of class II dental composite resin restorations cured with LED or QTH dental curing light; Blind, Cluster Randomized, In vitro cross sectional study

    PubMed Central

    2014-01-01

    Background The aim of this study is to compare the microleakage of Class II dental composite resin restorations which have been cured by three different LED (light emitting diode) light curing modes compared to control samples cured by QTH (quartz tungsten halogen) light curing units (LCUs), to determine the most effective light curing unit and mode of curing. Results In this experimental study, class II cavities were prepared on 100 sound human premolars which have been extracted for orthodontic treatment. The teeth were randomly divided into four groups; three experimental and one control group of 25 teeth each. Experimental groups were cured by either conventional, pulse-delay, or ramped curing modes of LED. The control group was cured for 20 seconds by QTH. The restorations were thermocycled (1000 times, between 5 and 55°C, for 5 seconds dwell time), dyed, sectioned mesio-distally and viewed under stereo-microscope (40×) magnification. Teeth were then scored on a 0 to 4 scale based on the amount of microleakage. The data were analyzed by Chi-square test. No significant difference was demonstrated between the different LCUs (light curing units), or modes of curing, at the enamel side (p > 0.05). At the dentin side, all modes of LED curing could significantly reduce microleakage (p < 0.05). The results suggest that slow start curing improves marginal integrity and seal. High intense curing endangers those aims. Conclusions Comparison between the three LED mode cured composite resin restorations and QTH curing showed LED curing in all modes is more effective than QTH for reducing microleakage. Both LED and QTH almost completely eliminate the microleakage on the enamel side, however none of them absolutely eliminated microleakage on the dentin side. PMID:24990296

  6. Mode of birth and medical interventions among women at low risk of complications: A cross-national comparison of birth settings in England and the Netherlands.

    PubMed

    de Jonge, Ank; Peters, Lilian; Geerts, Caroline C; van Roosmalen, Jos J M; Twisk, Jos W R; Brocklehurst, Peter; Hollowell, Jennifer

    2017-01-01

    To compare mode of birth and medical interventions between broadly equivalent birth settings in England and the Netherlands. Data were combined from the Birthplace study in England (from April 2008 to April 2010) and the National Perinatal Register in the Netherlands (2009). Low risk women in England planning birth at home (16,470) or in freestanding midwifery units (11,133) were compared with Dutch women with planned home births (40,468). Low risk English women with births planned in alongside midwifery units (16,418) or obstetric units (19,096) were compared with Dutch women with planned midwife-led hospital births (37,887). CS rates varied across planned births settings from 6.5% to 15.5% among nulliparous and 0.6% to 5.1% among multiparous women. CS rates were higher among low risk nulliparous and multiparous English women planning obstetric unit births compared to Dutch women planning midwife-led hospital births (adjusted (adj) OR 1.89 (95% CI 1.64 to 2.18) and 3.66 (2.90 to 4.63) respectively). Instrumental vaginal birth rates varied from 10.7% to 22.5% for nulliparous and from 0.9% to 5.7% for multiparous women. Rates were lower in the English comparison groups apart from planned births in obstetric units. Transfer, augmentation and episiotomy rates were much lower in England compared to the Netherlands for all midwife-led groups. In most comparisons, epidural rates were higher among English groups. When considering maternal outcomes, findings confirm advantages of giving birth in midwife-led settings for low risk women. Further research is needed into strategies to decrease rates of medical intervention in obstetric units in England and to reduce rates of avoidable transfer, episiotomy and augmentation of labour in the Netherlands.

  7. Mode of birth and medical interventions among women at low risk of complications: A cross-national comparison of birth settings in England and the Netherlands

    PubMed Central

    Peters, Lilian; Geerts, Caroline C.; van Roosmalen, Jos J. M.; Twisk, Jos W. R.; Brocklehurst, Peter; Hollowell, Jennifer

    2017-01-01

    Objectives To compare mode of birth and medical interventions between broadly equivalent birth settings in England and the Netherlands. Methods Data were combined from the Birthplace study in England (from April 2008 to April 2010) and the National Perinatal Register in the Netherlands (2009). Low risk women in England planning birth at home (16,470) or in freestanding midwifery units (11,133) were compared with Dutch women with planned home births (40,468). Low risk English women with births planned in alongside midwifery units (16,418) or obstetric units (19,096) were compared with Dutch women with planned midwife-led hospital births (37,887). Results CS rates varied across planned births settings from 6.5% to 15.5% among nulliparous and 0.6% to 5.1% among multiparous women. CS rates were higher among low risk nulliparous and multiparous English women planning obstetric unit births compared to Dutch women planning midwife-led hospital births (adjusted (adj) OR 1.89 (95% CI 1.64 to 2.18) and 3.66 (2.90 to 4.63) respectively). Instrumental vaginal birth rates varied from 10.7% to 22.5% for nulliparous and from 0.9% to 5.7% for multiparous women. Rates were lower in the English comparison groups apart from planned births in obstetric units. Transfer, augmentation and episiotomy rates were much lower in England compared to the Netherlands for all midwife-led groups. In most comparisons, epidural rates were higher among English groups. Conclusions When considering maternal outcomes, findings confirm advantages of giving birth in midwife-led settings for low risk women. Further research is needed into strategies to decrease rates of medical intervention in obstetric units in England and to reduce rates of avoidable transfer, episiotomy and augmentation of labour in the Netherlands. PMID:28749944

  8. GATEWAY Demonstrations: Tuning Hospital Lighting: Evaluating Tunable LED Lighting at the Swedish Hospital Behavioral Health Unit in Seattle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkerson, Andrea; Davis, Robert G.; Clark, Edward

    The GATEWAY program evaluated a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

  9. GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    Summary of a GATEWAY report evaluation of a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

  10. Tobacco industry tactics with advertisements at the point of sale in Mumbai.

    PubMed

    Patel, S; Rendell, H; Maudgal, S; Oswal, K

    2013-01-01

    The Cigarettes and Other Tobacco Products (Prohibition of Advertising and Regulations of Trade and Commerce, Production, Supply and Distribution) Act 2003 (COTPA) set out a number of stringent regulations to address tobacco promotion, some of which were revised in 2004. The aim of the study was to monitor the industry tactics at the point of sale with advertising and promotion of tobacco product in Mumbai. The study was carried out by Cancer Patients Aid Association in Mumbai with the help of volunteers. The surveys consisted of two parts, observational information and an interviewer administered questionnaire. Observations like size of board, display of advertisement, backlighting, and use of any promotion were noted. A questionnaire captured information about any incentives from tobacco companies for advertisement and promotion was administered to the vendors who agreed to participate. Study was approved by the Scientific and independent Ethics committee. Total 125 establishments (58 shops, 55 kiosks, 12 other sites) with display boards were surveyed across 5 wards in Mumbai. It was noted that the most common violation was the placements of boards, mainly placed above the shop. The display boards were oversized and few of the advertisements were highlighted with backlights. Out of 125 tobacco vendors surveyed, 107 (85.5%) vendors agreed to answer the questionnaire. We noted that a majority of 67% (84 vendors) stated that they had been approached by tobacco companies to place the signages during the past 5 years post COTPA came into effect. 79 vendors (65 %) admitted to being paid by the tobacco companies. Although the civil society and various non-governmental organizations has casted voice against the industry tactics but ineffective enforcement of the law is a major hurdle. It is likely that cigarette companies will be further able to overcome advertising restrictions by finding loopholes in tobacco legislation unless the decision makers ban it comprehensively as evident in other countries.

  11. Constancy of built-in luminance meter measurements in diagnostic displays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M.

    2013-12-15

    Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49 336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25 000 BLH and those with more than 25 000 BLH. Bias between meters was also evaluated.more » Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35 000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25 000 and greater than 25 000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35 000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.« less

  12. Backlighting the Universe: Understanding the Large-Scale Structure Through Cosmic Microwave Background Observations

    NASA Astrophysics Data System (ADS)

    Schaan, Emmanuel Sebastien

    The primary fluctuations in the cosmic microwave background (CMB), the leftover heat from the big bang, have revealed invaluable clues about our universe (age, history, geometry, composition), and are now measured almost to the cosmic variance limit. While important fundamental physics questions remain to be answered from the primary CMB alone (e.g., detection of gravitational waves from inflation, number of relativistic species), many others require looking beyond the primary anisotropies: what is dark energy, this mysterious component responsible for the accelerated expansion of the universe? What is the nature of the dark matter, five times more abundant than ordinary matter? What are the masses of the neutrinos? The clustering pattern in the spatial distribution of galaxies across the universe, the so-called large-scale structure (LSS), contains the key to these fundamental physics questions, as well as many tightly related astrophysical questions: what are the key processes in galaxy formation? How did the universe transition from neutral to ionized, one billion years after the big bang? However, several hurdles hinder extracting this information: non-linear evolution under gravity is complex to model and turns independent Gaussian initial conditions into coupled non-Gaussian modes; uncertain astrophysical effects obscure the connection between visible and dark matter, and alter the matter power spectrum on small-scales; LSS observables are often complex and systematics-limited. In this thesis, I tackle these issues and explore various ways of using the CMB as a backlight for the LSS, to illuminate aspects of its uncertain physics and systematics. In the coming years, ever more sensitive CMB experiments (AdvACT, SPT-3G, Simons Observatory, CMB Stage 4) will overlap with imaging surveys (DES, HSC, LSST, Euclid, WFIRST) and spectroscopic surveys (DESI, PFS), thus greatly magnifying the power of the methods I developed, and helping to answer some of the most pressing astrophysics and fundamental physics questions.

  13. X-ray diffraction diagnostic design for the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Ahmed, Maryum F.; House, Allen; Smith, R. F.; Ayers, Jay; Lamb, Zachary S.; Swift, David W.

    2013-09-01

    This paper describes the design considerations for Target Diffraction In-Situ (TARDIS), an x-ray diffraction diagnostic at the National Ignition Facility. A crystal sample is ramp-compressed to peak pressures between 10 and 30 Mbar and, during a pressure hold period, is probed with quasi-monochromatic x-rays emanating from a backlighter source foil. The crystal spectrography diffraction lines are recorded onto image plates. The crystal sample, filter, and image plates are packaged into one assembly, allowing for accurate and repeatable target to image plate registration. Unconverted laser light impinges upon the device, generating debris, the effects of which have been mitigated. Dimpled blast shields, high strength steel alloy, and high-z tungsten are used to shield and protect the image plates. A tapered opening was designed to provide adequate thickness of shielding materials without blocking the drive beams or x-ray source from reaching the crystal target. The high strength steel unit serves as a mount for the crystal target and x-ray source foil. A tungsten body contains the imaging components. Inside this sub-assembly, there are three image plates: a 160 degree field of view curved plate directly opposite the target opening and two flat plates for the top and bottom. A polycarbonate frame, coated with the appropriate filter material and embedded with registration features for image plate location, is inserted into the diagnostic body. The target assembly is metrologized and then the diagnostic assembly is attached.

  14. An exploration of influences on women’s birthplace decision-making in New Zealand: a mixed methods prospective cohort within the Evaluating Maternity Units study

    PubMed Central

    2014-01-01

    Background There is worldwide debate surrounding the safety and appropriateness of different birthplaces for well women. One of the primary objectives of the Evaluating Maternity Units prospective cohort study was to compare the clinical outcomes for well women, intending to give birth in either an obstetric-led tertiary hospital or a free-standing midwifery-led primary maternity unit. This paper addresses a secondary aim of the study – to describe and explore the influences on women’s birthplace decision-making in New Zealand, which has a publicly funded, midwifery-led continuity of care maternity system. Methods This mixed method study utilised data from the six week postpartum survey and focus groups undertaken in the Christchurch area in New Zealand (2010–2012). Christchurch has a tertiary hospital and four primary maternity units. The survey was completed by 82% of the 702 study participants, who were well, pregnant women booked to give birth in one of these places. All women received midwifery-led continuity of care, regardless of their intended or actual birthplace. Results Almost all the respondents perceived themselves as the main birthplace decision-makers. Accessing a ‘specialist facility’ was the most important factor for the tertiary hospital group. The primary unit group identified several factors, including ‘closeness to home’, ‘ease of access’, the ‘atmosphere’ of the unit and avoidance of ‘unnecessary intervention’ as important. Both groups believed their chosen birthplace was the right and ‘safe’ place for them. The concept of ‘safety’ was integral and based on the participants’ differing perception of safety in childbirth. Conclusions Birthplace is a profoundly important aspect of women’s experience of childbirth. This is the first published study reporting New Zealand women’s perspectives on their birthplace decision-making. The groups’ responses expressed different ideologies about childbirth. The tertiary hospital group identified with the ‘medical model’ of birth, and the primary unit group identified with the ‘midwifery model’ of birth. Research evidence affirming the ‘clinical safety’ of primary units addresses only one aspect of the beliefs influencing women’s birthplace decision-making. In order for more women to give birth at a primary unit other aspects of women’s beliefs need addressing, and much wider socio-political change is required. PMID:24951093

  15. Association between level of exposure to death and dying and professional quality of life among palliative care workers.

    PubMed

    Samson, Tali; Shvartzman, Pesach

    2017-06-23

    Exposure to the death and dying of others is an anxiety-provoking condition that can contribute to psychological stress. However, the results of empirical studies that evaluated work-related outcomes among physicians and nurses with repeated exposure to dying patients are not consistent. Our aim was to evaluate whether a high level of exposure to death and dying (LED) can increase the risk for poor professional quality of life (ProQoL) in most healthcare workers, but it can also improve ProQoL in a subset of healthcare workers with specific characteristics. We employed a cross-sectional survey designed to better understand the role of LED as a predictor of ProQoL among healthcare workers. Comparison of physicians and nurses with high LED (home-based palliative care units) with a matched group of physicians and nurses with low LED (primary care units) and evaluation of possible interaction effects among LED, death anxiety (DA), and engagement as predictors of ProQoL. The final sample included 110 questionnaires from the high-LED group (response rate = 39%) and 131 from the low-LED (response rate = 24%) group. Workers with high LED reported an increased level of compassion satisfaction (CS) and low to moderate levels of burnout (BU) and secondary traumatic stress (STS), with no significant differences with respect to other healthcare providers. Although levels of CS, STS, and BU did not differ between groups, a univariate MANOVA revealed that the interaction effect of LED × Engagement reduced levels of CS and that the interaction effect of LED × DA increased STS among workers with high LED. LED was significantly correlated with ProQoL among healthcare workers with high LED due to the reported interaction effect. These findings imply, for the first time, that there is a possible correlation between engagement and the risk for poor ProQoL among workers with high LED. Further research is essential to gain a better understanding of this issue.

  16. Pulp chamber temperature rise during curing of resin-based composites with different light-curing units.

    PubMed

    Durey, Kathryn; Santini, Ario; Miletic, Vesna

    2008-01-01

    The purpose of the present study was to measure the intrapulpal temperature rise occurring during polymerisation of different shades of resin-based composites (RBCs), and two light-emitting diode (LED) units. Seventy non-carious permanent molars, that had been extracted for orthodontic purposes and stored in 2% thymol for not more than four months, were selected. Patient age range was 11-18 years. Standard cavity preparation with standardised remaining dentine thickness and placement of thermocouples (TCs) was prepared using a novel split-tooth technique. Cavities were filled with one of two shades of RBC (A2 and C4, Filtek Z250, 3M ESPE, Seefeld, Germany), and cured with two LED high-intensity units (Elipar Freelight2, 3M ESPE, Seefeld, Germany; Bluephase, Ivoclar Vivadent, Schaan, Liechtenstein) and a conventional halogen light-curing unit (LCU) (Prismetics Lite 2, Dentsply, Weybridge, Surrey, UK) as a control. Pulp temperature rises during bonding [A2 results: H;2.67/0.48:E;5.24/1.32;B;5.99/1.61] were always greater than during RBC curing [A2 results: 2.44/0.63;E3.34/0.70;B3.38/0.60], and these were significant for both LED lights but not for the halogen control, irrespective of shade (Mann-Whitney test: 95% confidence limits). Temperature rises were at times in excess of the values normally quoted as causing irreversible pulp damage. Pulp temperature rises during bonding were higher with the LED lights than with the halogen control. There was no significant difference in temperature rise between the two LED lights when bonding but there was a significant difference between the two LED lights and the halogen control LCUs (Kruskal-Wallis Test: 95% confidence limits). The results support the view that there is a potential risk for heat-induced pulpal injury when light-curing RBCs. The risk is greater during bonding and with high energy, as compared to low-energy output systems. As the extent of tolerable thermal trauma by the pulp tissues is unknown, care and consideration should be given to the choice of LCU and the exposure time when curing RBCs, and especially during bonding.

  17. Differential pulse amplitude modulation for multiple-input single-output OWVLC

    NASA Astrophysics Data System (ADS)

    Yang, S. H.; Kwon, D. H.; Kim, S. J.; Son, Y. H.; Han, S. K.

    2015-01-01

    White light-emitting diodes (LEDs) are widely used for lighting due to their energy efficiency, eco-friendly, and small size than previously light sources such as incandescent, fluorescent bulbs and so on. Optical wireless visible light communication (OWVLC) based on LED merges lighting and communications in applications such as indoor lighting, traffic signals, vehicles, and underwater communications because LED can be easily modulated. However, physical bandwidth of LED is limited about several MHz by slow time constant of the phosphor and characteristics of device. Therefore, using the simplest modulation format which is non-return-zero on-off-keying (NRZ-OOK), the data rate reaches only to dozens Mbit/s. Thus, to improve the transmission capacity, optical filtering and pre-, post-equalizer are adapted. Also, high-speed wireless connectivity is implemented using spectrally efficient modulation methods: orthogonal frequency division multiplexing (OFDM) or discrete multi-tone (DMT). However, these modulation methods need additional digital signal processing such as FFT and IFFT, thus complexity of transmitter and receiver is increasing. To reduce the complexity of transmitter and receiver, we proposed a novel modulation scheme which is named differential pulse amplitude modulation. The proposed modulation scheme transmits different NRZ-OOK signals with same amplitude and unit time delay using each LED chip, respectively. The `N' parallel signals from LEDs are overlapped and directly detected at optical receiver. Received signal is demodulated by power difference between unit time slots. The proposed scheme can overcome the bandwidth limitation of LEDs and data rate can be improved according to number of LEDs without complex digital signal processing.

  18. HCA leading the way to change.

    PubMed

    2014-06-03

    A hospital ward run by healthcare assistants? Some might be sceptical, but not patients at Headley Court Defence Medical Rehabilitation Centre in Surrey who are about to be discharged from the military into civvy street. For them, the HCA-led ward is a welcome change from the traditional medically intense nurse-led units.

  19. Bioenergy News | Bioenergy | NREL

    Science.gov Websites

    . April 13, 2018 News Release: Research Team Engineers a Better Plastic-Degrading Enzyme A breakthrough in enzyme research led by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) and the United Kingdom's University of Portsmouth has led to an improved variant of an enzyme that can

  20. An American tale - professional conflicts in anaesthesia in the United States: implications for the United Kingdom.

    PubMed

    Kane, M; Smith, A F

    2004-08-01

    Professional conflict between nurse anaesthetists and anaesthesiologists in the United States of America is well known in the UK but has not been explored and documented in detail. We present an account, based on critical analysis of published literature and other documentary evidence, of the historical, professional and financial factors which have led to this. In the USA, anaesthesia developed as a nursing specialty until physicians began to take on this work after the Second World War. Payment arrangements between the 1960s and the 1990s made anaesthesiology a lucrative career choice for medical graduates and this led both to considerable growth in the number of anaesthesiologists and to a strengthening of the resolve of nurse anaesthetists to retain their scope of work and preserve their professional status. Changes in payment regulations in the 1980s and 1990s threatened anaesthesiologists' income and led to re-appraisal of evidence over relative cost-effectiveness and safety of different provider models. More recently, the terms of engagement have shifted from disputes over evidence to political lobbying to promote the professional capabilities and status of each of the anaesthesia providers. Factors of relevance to possible changes in the provision of anaesthesia in the United Kingdom are highlighted.

  1. Whose Culture?: Monolithic Cultures and Subcultures in Early Childhood Settings

    ERIC Educational Resources Information Center

    Halttunen, Leena

    2017-01-01

    In Finland, day care centre directors have traditionally led only a single unit, but after the recent merging of many units, most directors simultaneously lead several, physically separate units. These organizations are called distributed organizations. This study was carried out in two distributed day care organizations. The findings are based on…

  2. Teaching the Manhattan Project

    ERIC Educational Resources Information Center

    Schibuk, Elizabeth

    2015-01-01

    This article describes a nuclear chemistry unit on the Manhattan Project, a research effort that led to the development of the world's first nuclear weapons during World War II. The unit is appropriate for an introductory high school chemistry or physics course and takes from four to six weeks. The unit poses this essential question: "Over…

  3. Droplet combustion at reduced gravity

    NASA Technical Reports Server (NTRS)

    Dryer, F. L.; Williams, F. A.

    1988-01-01

    The current work involves theoretical analyses of the effects identified, experiments in the NASA Lewis drop towers performed in the middeck areas of the Space Shuttle. In addition, there is laboratory work associated with the design of the flight apparatus. Calculations have shown that some of the test-matrix data can be obtained in drop towers, and some are achievable only in the space experiments. The apparatus consists of a droplet dispensing device (syringes), a droplet positioning device (opposing, retractable, hollow needles), a droplet ignition device (two matched pairs of retractable spark electrodes), gas and liquid handling systems, a data acquisition system (mainly giving motion-picture records of the combustion in two orthogonal views, one with backlighting for droplet resolution), and associated electronics.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Landen, O. L.

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energiesmore » relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.« less

  5. Polar tent for reduced perturbation of NIF ignition capsules

    NASA Astrophysics Data System (ADS)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  6. Annular flow in rod-bundle: Effect of spacer on disturbance waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, Son H.; Kunugi, Tomoaki

    2016-08-01

    A high-speed camera technique is used to study the effect of spacers on the disturbance waves present in annular two-phase flow within a rod-bundle geometry. Images obtained using a backlight configuration to visualize the spacer-wave interactions at the micro-scale resolution (in time and space) are discussed. This paper also presents additional images obtained using a reflected light configuration which provides new observations of the disturbance waves. These images show the separation effect caused by the spacer on the liquid film in which the size of generated liquid droplets can be controlled by the gas superficial velocity. Furthermore, the data confirmmore » that the spacer breaks the circumferential coherent structures of the waves.« less

  7. Talbot-Lau x-ray deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments (invited).

    PubMed

    Valdivia, M P; Stutman, D; Stoeckl, C; Mileham, C; Begishev, I A; Theobald, W; Bromage, J; Regan, S P; Klein, S R; Muñoz-Cordovez, G; Vescovi, M; Valenzuela-Villaseca, V; Veloso, F

    2016-11-01

    Talbot-Lau X-ray deflectometry (TXD) has been developed as an electron density diagnostic for High Energy Density (HED) plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping were demonstrated for 25-29 J, 8-30 ps laser pulses using copper foil targets. Moiré pattern formation and grating survival were also observed using a copper x-pinch driven at 400 kA, ∼1 kA/ns. These results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

  8. Proven high-performance display solution

    NASA Astrophysics Data System (ADS)

    Johnson, Rick J.; Shaw, James E.; Mosier, Don; Liss, Raymond L.; Prouty, Todd D.; Davis, Josh; Marzen, Vincent P.; Deloy, Christian T.

    2002-08-01

    Rockwell Collins serves both the military and the commercial segments by exploiting the common elements of these applications. Rockwell Collins has created a liquid crystal display family capable of 100:1 contrast ratio, 40:1 high ambient contrast, 0.25% specular reflectance, 0.1% diffuse reflectance, enhanced color stability over +/- 55H, 0-30V field of view, 300 fL with 10K:1 dimming range, color NVIS B compliance while exceeding environmental performance requirements though ruggedization. In order to meet the full range of display requirements at a system level, all the components must be understood and managed to meet the end solution of the final system. This paper details Rockwell Collins' optical performance using an avionics grade panel, third generation custom compensation, and solid state backlight.

  9. KSC-08pd2340

    NASA Image and Video Library

    2008-08-07

    CAPE CANAVERAL, Fla. – The Fine Guidance Sensor, or FGS, is being prepared for backlight inspection and cleaning in the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center. The FGS is part of the payload for the fifth and final Hubble servicing mission, STS-125, aboard space shuttle Atlantis. An FGS consists of a large structure housing a collection of mirrors, lenses, servos, prisms, beam splitters and photomultiplier tubes. There are three fine guidance sensors on Hubble located at 90-degree intervals around the circumference of the telescope. Along with the gyroscopes, the optical sensors are a key component of Hubble’s highly complex but extraordinarily effective “pointing control system.” Atlantis is targeted to launch Oct. 8. Photo credit: NASA/Jack Pfaller

  10. Talbot-Lau X-ray Deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments

    DOE PAGES

    Valdivia, M. P.; Stutman, D.; Stoeckl, C.; ...

    2016-04-21

    Talbot-Lau X-ray Deflectometry has been developed as an electron density diagnostic for High Energy Density plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping was demonstrated for 25-29 J, 8-30 ps laser pulses using copper foil targets. Moire pattern formation and grating survival was also observed using a copper x-pinch driven at 400 kA, ~1 kA/ns. Lastly, these results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

  11. Low-β magnetic reconnection driven by the intense lasers with a double-turn capacitor-coil

    NASA Astrophysics Data System (ADS)

    Yuan, Xiaoxia; Zhong, Jiayong; Zhang, Zhe; Zhou, Weimin; Teng, Jian; Li, Yutong; Han, Bo; Yuan, Dawei; Lin, Jun; Liu, Chang; Li, Yanfei; Zhu, Baojun; Wei, Huigang; Liang, Guiyun; Hong, Wei; He, Shukai; Yang, Siqian; Zhao, Yongqiang; Deng, Zhigang; Lu, Feng; Zhang, Zhimeng; Zhu, Bin; Zhou, Kainan; Su, Jingqin; Zhao, Zongqing; Gu, Yuqiu; Zhao, Gang; Zhang, Jie

    2018-06-01

    A double-turn capacitor-coil is used to produce a magnetic field (38.5 T) and construct a topology of magnetic reconnection in a low-β (β < 1) plasma environment. The device is constructed with two metallic U-turn coils connecting two parallel metallic disks. High energy lasers are employed to ablate one disk spontaneously driving two currents in the two coils, which produces an interactive magnetic field topology. We demonstrated through experiments and numerical simulations that the reconnection process takes place between two non-uniform magnetic fields created by the coils, and that the plasma state and the associated magnetic topology in the process can be seen via the technology of the optical probe beam and the proton backlight.

  12. Spool piece aperture: warm to cold temperature position changes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McInturff, A.D.

    1982-12-01

    In an effort to determine the position of the correction coil system contained in the spool piece in operation, a series of experiments were done in Lab 2 during the cryogenic testing of the spools. A special turn-around box was constructed which had a window through which a sighting could be made of the aperture of the coil packages. A set of four survey monuments were constructed with three point suspension, which were back-lighted by placing a small bulb behind each target which could be turned on individually external to the spool string while under vacuum and at any temperature.more » The targets were located at the ends of each correction coil package in their beam tube.« less

  13. Improvement of density resolution in short-pulse hard x-ray radiographic imaging using detector stacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borm, B.; Gärtner, F.; Khaghani, D.

    2016-09-15

    We demonstrate that stacking several imaging plates (IPs) constitutes an easy method to increase hard x-ray detection efficiency. Used to record x-ray radiographic images produced by an intense-laser driven hard x-ray backlighter source, the IP stacks resulted in a significant improvement of the radiograph density resolution. We attribute this to the higher quantum efficiency of the combined detectors, leading to a reduced photon noise. Electron-photon transport simulations of the interaction processes in the detector reproduce the observed contrast improvement. Increasing the detection efficiency to enhance radiographic imaging capabilities is equally effective as increasing the x-ray source yield, e.g., by amore » larger drive laser energy.« less

  14. Role Of High Speed Photography In The Testing Capabilities Of The Arnold Engineering Development Center (AEDC) Range And Track Facilities

    NASA Astrophysics Data System (ADS)

    Hendrix, Roy E.; Dugger, Paul H.

    1983-03-01

    Since the onset of user testing in the AEDC aeroballistic ranges in 1961, concentrated efforts in such areas as model launching techniques, test environment simulation, and specialized instrumentation have been made to enhance the usefulness of these test facilities. A wide selection of specialized instrumentation has been developed over the years to provide, among other features, panoramic photographic coverage of test models during flight. Pulsed ruby lasers, xenon flash lamps, visible-light spark sources, and flash X-ray systems are employed as short-duration radiation sources in various front-light and back-light photographic systems. Visible-light and near infrared image intensifier diodes are used to achieve high-speed shuttering in photographic pyrometry systems that measure surface temperatures of test models in flight. Turbine-driven framing cameras are used to provide multiframe photography of such high-speed phenomena as impact debris formation and model encounter with erosive fields. As a result, the capabilities of these ballistic range test units have increased significantly in regard to the types of tests that can be accommodated and to the quality and quantity of data that can be provided. Presently, five major range and companion track facilities are active in conducting hypervelocity testing in AEDC's von K6rman Gas Dynamics Facility (VKF): Ranges G, K, and S-1 and Tracks G and K. The following types of tests are conducted in these test units: ablation/erosion, transpiration-cooled nosetip (TCNT), nosetip transition, heat transfer, aerodynamic, cannon projectile, rocket contrail, reentry physics, and hypervelocity impact. The parallel achievements in high-speed photography and testing capabilities are discussed, and the significant role of photographic systems in the development of the overall testing capabilities of the AEDC range and track facilities is illustrated in numerous examples of photographic results.

  15. The Department of Defense and Homeland Security relationship: Hurricane Katrina through Hurricane Irene.

    PubMed

    Weaver, John Michael

    2015-01-01

    This research explored federal intervention with the particular emphasis on examining how a collaborative relationship between Department of Defense (DOD) and Homeland Security (DHS) led to greater effectiveness between these two federal departments and their subordinates (United States Northern Command and Federal Emergency Management Agency, respectively) during the preparation and response phases of the disaster cycle regarding US continental-based hurricanes. Through the application of a two-phased, sequential mixed methods approach, this study determined how their relationship has led to longitudinal improvements in the years following Hurricane Katrina, focusing on hurricanes as the primary unit of analysis.

  16. Significant reduction in energy for plant-growth lighting in space using targeted LED lighting and spectral manipulation

    NASA Astrophysics Data System (ADS)

    Poulet, L.; Massa, G. D.; Morrow, R. C.; Bourget, C. M.; Wheeler, R. M.; Mitchell, C. A.

    2014-07-01

    Bioregenerative life-support systems involving photoautotrophic organisms will be necessary to sustain long-duration crewed missions at distant space destinations. Since sufficient sunlight will not always be available for plant growth at many space destinations, efficient electric-lighting solutions are greatly needed. The present study demonstrated that targeted plant lighting with light-emitting diodes (LEDs) and optimizing spectral parameters for close-canopy overhead LED lighting allowed the model crop leaf lettuce (Lactuca sativa L. cv. 'Waldmann's Green') to be grown using significantly less electrical energy than using traditional electric-lighting sources. Lettuce stands were grown hydroponically in a growth chamber controlling temperature, relative humidity, and CO2 level. Several red:blue ratios were tested for growth rate during the lag phase of lettuce growth. In addition, start of the exponential growth phase was evaluated. Following establishment of a 95% red + 5% blue spectral balance giving the best growth response, the energy efficiency of a targeted lighting system was compared with that of two total coverage (untargeted) LED lighting systems throughout a crop-production cycle, one using the same proportion of red and blue LEDs and the other using white LEDs. At the end of each cropping cycle, whole-plant fresh and dry mass and leaf area were measured and correlated with the amount of electrical energy (kWh) consumed for crop lighting. Lettuce crops grown with targeted red + blue LED lighting used 50% less energy per unit dry biomass accumulated, and the total coverage white LEDs used 32% less energy per unit dry biomass accumulated than did the total coverage red + blue LEDs. An energy-conversion efficiency of less than 1 kWh/g dry biomass is possible using targeted close-canopy LED lighting with spectral optimization. This project was supported by NASA grant NNX09AL99G.

  17. Colonised by Quality? Teacher Identities in a Research-Led Institution

    ERIC Educational Resources Information Center

    Skelton, Alan

    2012-01-01

    This article explores the impact of quality assurance and enhancement initiatives on teacher identities in higher education. Data from an interview-based study of a research-led institution in the United Kingdom are drawn upon to consider the implications of quality--for example, whether it has captured the inner assumptive worlds of higher…

  18. Portrait of a Teacher-Led School

    ERIC Educational Resources Information Center

    Nazareno, Lori

    2013-01-01

    Imagine a school with no principal and with a leadership structure that holds teachers accountable for the learning of all students. About 50 such teacher-led schools currently operate across the United States, and this article tells the story of one of them. The Mathematics and Science Leadership Academy (MSLA) in Denver, Colorado, serves about…

  19. Spectral effects of light-emitting diodes on plant growth and development: The importance of green and blue light

    NASA Astrophysics Data System (ADS)

    Cope, K. R.; Bugbee, B.

    2011-12-01

    Light-emitting diodes (LEDs) are an emerging technology for plant growth lighting. Due to their narrow spectral output, colored LEDs provide many options for studying the spectral effects of light on plants. Early on, efficient red LEDs were the primary focus of photobiological research; however, subsequent studies have shown that normal plant growth and development cannot be achieved under red light without blue light supplementation. More recent studies have shown that red and blue (RB) LEDs supplemented with green light increase plant dry mass. This is because green light transmits more effectively through the leaf canopy than red and blue light, thus illuminating lower plant leaves and increasing whole-plant photosynthesis. Red, green and blue (RGB) light can be provided by either a conventional white light source (such as fluorescent lights), a combination of RGB LEDs, or from recently developed white LEDs. White LEDs exceed the efficiency of fluorescent lights and have a comparable broad spectrum. As such, they have the potential to replace fluorescent lighting for growth-chamber-based crop production both on Earth and in space. Here we report the results of studies on the effects of three white LED types (warm, neutral and cool) on plant growth and development compared to combinations of RB and RGB LEDs. Plants were grown under two constant light intensities (200 and 500 μmol m-2 s-1). Temperature, environmental conditions and root-zone environment were uniformly maintained across treatments. Phytochrome photoequilbria and red/far-red ratios were similar among treatments and were comparable to conventional fluorescent lights. Blue light had a significant effect on both plant growth (dry mass gain) and development (dry mass partitioning). An increase in the absolute amount (μmol m-2 s-1) of blue light from 0-80 μmol m-2 s-1 resulted in a decrease in stem elongation, independent of the light intensity. However, an increase in the relative amount (%) of blue light caused a decrease in specific leaf area (leaf area per unit leaf mass). As the relative amount of blue light increased, chlorophyll concentration per unit leaf area increased, but chlorophyll concentration per unit leaf mass remained constant. The relative amount of blue light increased total dry mass in some species while it remained constant in others. An increase in the fraction of green light increased dry mass in radish. Overall, white LEDs provided a more uniform spectral distribution, reduced stem elongation and leaf area, and maintained or increased dry mass as compared to RB and RGB LEDs. Cool white LEDs are more electrically efficient than the other two white LEDs and have sufficient blue light for normal plant growth and development at both high and low light intensities. Compared to sunlight, cool white LEDs are perhaps deficient in red light and may therefore benefit from supplementation with red LEDs. Future studies will be conducted to test this hypothesis. These results have significant implication for LADA growth chambers which are currently used for vegetable production on the International Space Station.

  20. The Role of United States Army Special Forces in Operation NOBEL OBELISK

    DTIC Science & Technology

    2001-06-01

    This thesis will examine U.S. Special Forces contributions to Operation NOBEL OBELISK, a Marine- led joint NEO in Sierra Leone in 1997. It is further...success of Joint Task Force NOBEL OBELISK. This operation led to the eventual safety of in excess of 2,500 civilians. Many of those civilians were... led many observers, both within and outside the country, to be optimistic about the future of democracy and the rule of law.”6 Unfortunately, twenty

  1. High power LED standard light sources for photometric applications

    NASA Astrophysics Data System (ADS)

    Ivashin, Evgeniy; Ogarev, Sergey; Khlevnoy, Boris; Shirokov, Stanislav; Dobroserdov, Dmitry; Sapritsky, Victor

    2018-02-01

    High power LED light sources have been developed as possible new VNIIOFI standard sources for luminous intensity, luminous flux and colour measurements. Stability, repeatability and spatial uniformity of the sources were investigated and demonstrated high accuracy and homogeneity. The paper describes different tests on one of the manufactured sources. In the future, these LED light sources are planned to be used as standard luminous flux sources to transfer the units of luminous intensity and luminous flux from gonio-spectrometer to sphere-spectrometer.

  2. Corrosion resistance of grouted post-tensioning systems : [summary].

    DOT National Transportation Integrated Search

    2013-08-01

    The increased popularity of post-tensioned bridge construction in the United States has led to concerns about corrosion and its impact on the life cycle of these bridges. Although the vast majority of post-tensioned bridges in the United States have ...

  3. A History of United States Catholic Schooling: NCEA Keynote Series No. 2.

    ERIC Educational Resources Information Center

    Buetow, Harold A.

    Roman Catholic schools in the United States have made significant contributions which include the first schools in many geographic areas, the first textbook in the United States, and the first dictionaries of some Indian languages. Early attempts to establish Catholic schools led to incidents which required heroism of the leaders and sacrifices by…

  4. Clinical outcomes of the first midwife-led normal birth unit in China: a retrospective cohort study.

    PubMed

    Cheung, Ngai Fen; Mander, Rosemary; Wang, Xiaoli; Fu, Wei; Zhou, Hong; Zhang, Liping

    2011-10-01

    to report the clinical outcomes of the first six months of operation of an innovative midwife-led normal birth unit (MNBU) in China in 2008, aiming to facilitate normal birth and enhance midwifery practice. an urban hospital with 2000-3000 deliveries per year. this study was part of a major action research project that led to implementation of the MNBU. A retrospective cohort and a questionnaire survey were used. The data were analysed thematically. the outcomes of the first 226 women accessing the MNBU were compared with a matched retrospective cohort of 226 women accessing standard care. In total, 128 participants completed a satisfaction questionnaire before discharge. mode of birth and model of care. the vaginal birth rate was 87.6% in the MNBU compared with 58.8% in the standard care unit. All women who accessed the MNBU were supported by both a midwife and a birth companion, referred to as 'two-to-one' care. None of the women labouring in the standard care unit were identified as having a birth companion. the concept of 'two-to-one' care emerged as fundamental to women's experiences and utilisation of midwives' skills to promote normal birth and decrease the likelihood of a caesarean section. the MNBU provides an environment where midwives can practice to the full extent of their role. The high vaginal birth rate in the MNBU indicates the potential of this model of care to reduce obstetric intervention and increase women's satisfaction with care within a context of extraordinary high caesarean section rates. midwife-led care implies a separation of obstetric care from maternity care, which has been advocated in many European countries. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. The Plant Research Unit: Long-Term Plant Growth Support for Space Station

    NASA Technical Reports Server (NTRS)

    Heathcote, D. G.; Brown, C. S.; Goins, G. D.; Kliss, M.; Levine, H.; Lomax, P. A.; Porter, R. L.; Wheeler, R.

    1996-01-01

    The specifications of the plant research unit (PRU) plant habitat, designed for space station operations, are presented. A prototype brassboard model of the PRU is described, and the results of the subsystems tests are outlined. The effects of the long term red light emitting diode (LED) illumination as the sole source for plant development were compared with red LEDs supplemented with blue wavelengths, and white fluorescent sources. It was found that wheat and Arabidopsis were able to complete a life cycle under red LEDs alone, but with differences in physiology and morphology. The differences noted were greatest for the Arabidopsis, where the time to flowering was increased under red illumination. The addition of 10 percent of blue light was effective in eliminating the observed differences. The results of the comparative testing of three nutrient delivery systems for the PRU are discussed.

  6. Comparison of the heat generation of light curing units.

    PubMed

    Bagis, Bora; Bagis, Yildirim; Ertas, Ertan; Ustaomer, Seda

    2008-02-01

    The aim of this study was to evaluate the heat generation of three different types of light curing units. Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental model was designed to fix the 1 mm distance between the tip of the light curing units and the thermocouple wire. Temperature changes were recorded in 10 second intervals up to 40 seconds. (10, 20, 30, and 40 seconds). Temperature measurements were repeated three times for every light curing unit after a one hour standby period. Statistical analysis of the results was performed using the analysis of variance (ANOVA) and the Bonferroni Test. The highest temperature rises (54.4+/-1.65 degrees C) occurred during activation of a PAC light curing unit for every test period (p<.05). The least temperature increase (11.8+/-1.3 degrees C) occurred with a LED curing unit for each tested period except for the measurement of the temperature rise using the QTH curing unit at the tenth second interval (p<.05). These results indicate the choice of light activation unit and curing time is important when polymerizing light activated resin based restorations to avoid any thermal damage to the pulp.

  7. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays.

    PubMed

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-09-19

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems.

  8. [Hygienic aspects of the use of LED light sources for general illumination in schools].

    PubMed

    Kuchma, V R; Sukhareva, L M; Teksheva, L M; Stepanova, M I; Sazaniuk, Z I

    2013-01-01

    For the time present becoming more common semiconductor sources of artificial lighting has become a more and more frequent practice. With the aim to study the impact of LEDs on the health of schoolchildren studies in experimental conditions (specially equipped classrooms) were performed. The comparative analysis of the state of vision, mental health and emotional state of pupils in primary, middle and high schools under fluorescent and LED lighting, meeting to the regulatory requirements, has revealed that the physiological cost of schooling in the use of LED units in classrooms is lower than in a traditional, fluorescent lighting.

  9. Theoretical and experimental analysis of AlGaInP micro-LED array with square-circle anode

    NASA Astrophysics Data System (ADS)

    Tian, Chao; Wang, Weibiao; Liang, Jingqiu; Liang, Zhongzhu; Qin, Yuxin; Lv, Jinguang

    2015-04-01

    An array of 320 × 240 micro-light-emitting diodes (micro-LEDs) based on an AlGaInP epitaxial wafer and with a unit size of 100 µm×100 µm was designed and fabricated. The optimum width of the isolation groove between adjacent light-emitting units was determined based on a compromise between full isolation of each LED and maximization of the light emitting area, and was found to be 20 µm. The grooves were filled with a mixed Si granule-polyurethane composite medium, because this type of insulating material can reflect part of the emitted light from the sidewall to the window layer in each light-emitting unit, and could thus improve lighting output efficiency. The 10-µm-wide square-circle anode was designed to increase the light emitting area while simultaneously being simple to fabricate. The device current used was in the 0.42-1.06 mA range to guarantee internal quantum efficiency of more than 85%, with a corresponding voltage range of 2-2.3 V. The layered temperature distribution in a single unit was simulated under a drive voltage of 2.2 V, and the maximum device temperature was 341 K. The micro-opto-electro-mechanical systems (MOEMS) technology-based fabrication process, experimental images of the device and device test results are presented here.

  10. Mechanical and Thermal Properties of Dental Composites Cured with CAD/CAM Assisted Solid-State Laser

    PubMed Central

    De Santis, Roberto; Gloria, Antonio; Maietta, Saverio; Martorelli, Massimo; De Luca, Alessandro; Spagnuolo, Gianrico; Riccitiello, Francesco; Rengo, Sandro

    2018-01-01

    Over the last three decades, it has been frequently reported that the properties of dental restorative composites cured with argon laser are similar or superior to those achieved with conventional halogen and light emitting diode (LED) curing units. Whereas laser curing is not dependent on the distance between the curing unit and the material, such distance represents a drawback for conventional curing units. However, a widespread clinical application of this kind of laser remains difficult due to cost, heavy weight, and bulky size. Recently, with regard to the radiation in the blue region of the spectrum, powerful solid-state lasers have been commercialized. In the current research, CAD (computer-aided design)/CAM (computer-aided manufacturing) assisted solid-state lasers were employed for curing of different dental restorative composites consisting of micro- and nanoparticle-reinforced materials based on acrylic resins. Commercial LED curing units were used as a control. Temperature rise during the photopolymerisation process and bending properties were measured. By providing similar light energy dose, no significant difference in temperature rise was observed when the two light sources provided similar intensity. In addition, after 7 days since curing, bending properties of composites cured with laser and LED were similar. The results suggested that this kind of laser would be suitable for curing dental composites, and the curing process does not suffer from the tip-to-tooth distance. PMID:29584683

  11. Theoretical and experimental analysis of AlGaInP micro-LED array with square-circle anode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Chao; University of Chinese Academy of Sciences, Beijing 100049; Wang, Weibiao, E-mail: wangwbcn@163.com

    An array of 320 × 240 micro-light-emitting diodes (micro-LEDs) based on an AlGaInP epitaxial wafer and with a unit size of 100 µm×100 µm was designed and fabricated. The optimum width of the isolation groove between adjacent light-emitting units was determined based on a compromise between full isolation of each LED and maximization of the light emitting area, and was found to be 20 µm. The grooves were filled with a mixed Si granule-polyurethane composite medium, because this type of insulating material can reflect part of the emitted light from the sidewall to the window layer in each light-emitting unit,more » and could thus improve lighting output efficiency. The 10-µm-wide square-circle anode was designed to increase the light emitting area while simultaneously being simple to fabricate. The device current used was in the 0.42–1.06 mA range to guarantee internal quantum efficiency of more than 85%, with a corresponding voltage range of 2–2.3 V. The layered temperature distribution in a single unit was simulated under a drive voltage of 2.2 V, and the maximum device temperature was 341 K. The micro-opto-electro-mechanical systems (MOEMS) technology-based fabrication process, experimental images of the device and device test results are presented here.« less

  12. The Search for next Practice: A UK Approach to Innovation in Schools

    ERIC Educational Resources Information Center

    Hannon, Valerie

    2009-01-01

    In 2002, the Labor Government in the UK established an Innovation Unit, within government, to support practitioner-led innovation in schools. Two considerations led to this action. First, there was an increasing sense that amidst the plethora of national strategies and change programs, an important element was in danger of being lost: the…

  13. Light-Emitting Diodes: A Hidden Treasure

    ERIC Educational Resources Information Center

    Planinšic, Gorazd; Etkina, Eugenia

    2014-01-01

    LEDs, or light-emitting diodes, are cheap, easy to purchase, and thus commonly used in physics instruction as indicators of electric current or as sources of light (Fig. 1). In our opinion LEDs represent a unique piece of equipment that can be used to collect experimental evidence, and construct and test new ideas in almost every unit of a general…

  14. Diverse Learners' Meaning Making of Informational Texts during Small Group, Peer-Led Discussions

    ERIC Educational Resources Information Center

    Bajor, Lisa

    2017-01-01

    The purpose of this qualitative case study is to examine small group, peer-led discussion as it connects to meaning-making of informational texts for diverse learners. Since students in the United States are currently struggling to meet informational text requirements outlined by the Common Core State Standards (National Governors Association…

  15. "Take Back Your Time": Facilitating a Student Led Teach-In

    ERIC Educational Resources Information Center

    Heyne, Linda A.

    2008-01-01

    "Take Back Your Time" (TBYT) is a movement founded by John De Graaf (2003) that exposes the issues of time poverty and overwork in the United States and Canada. This article features the process whereby undergraduate students study De Graaf's TBYT handbook, discuss its concepts, and organize a student-led TBYT "teach-in" for…

  16. Design of crossed-mirror array to form floating 3D LED signs

    NASA Astrophysics Data System (ADS)

    Yamamoto, Hirotsugu; Bando, Hiroki; Kujime, Ryousuke; Suyama, Shiro

    2012-03-01

    3D representation of digital signage improves its significance and rapid notification of important points. Our goal is to realize floating 3D LED signs. The problem is there is no sufficient device to form floating 3D images from LEDs. LED lamp size is around 1 cm including wiring and substrates. Such large pitch increases display size and sometimes spoils image quality. The purpose of this paper is to develop optical device to meet the three requirements and to demonstrate floating 3D arrays of LEDs. We analytically investigate image formation by a crossed mirror structure with aerial aperture, called CMA (crossed-mirror array). CMA contains dihedral corner reflectors at each aperture. After double reflection, light rays emitted from an LED will converge into the corresponding image point. We have fabricated CMA for 3D array of LEDs. One CMA unit contains 20 x 20 apertures that are located diagonally. Floating image of LEDs was formed in wide range of incident angle. The image size of focused beam agreed to the apparent aperture size. When LEDs were located three-dimensionally (LEDs in three depths), the focused distances were the same as the distance between the real LED and the CMA.

  17. The History of Uranium Mining and the Navajo People

    PubMed Central

    Brugge, Doug; Goble, Rob

    2002-01-01

    From World War II until 1971, the government was the sole purchaser of uranium ore in the United States. Uranium mining occurred mostly in the southwestern United States and drew many Native Americans and others into work in the mines and mills. Despite a long and well-developed understanding, based on the European experience earlier in the century, that uranium mining led to high rates of lung cancer, few protections were provided for US miners before 1962 and their adoption after that time was slow and incomplete. The resulting high rates of illness among miners led in 1990 to passage of the Radiation Exposure Compensation Act. PMID:12197966

  18. LED Curing Lights and Temperature Changes in Different Tooth Sites

    PubMed Central

    Armellin, E.; Bovesecchi, G.; Coppa, P.; Pasquantonio, G.; Cerroni, L.

    2016-01-01

    Objectives. The aim of this in vitro study was to assess thermal changes on tooth tissues during light exposure using two different LED curing units. The hypothesis was that no temperature increase could be detected within the dental pulp during polymerization irrespective of the use of a composite resin or a light-curing unit. Methods. Caries-free human first molars were selected, pulp residues were removed after root resection, and four calibrated type-J thermocouples were positioned. Two LED lamps were tested; temperature measurements were made on intact teeth and on the same tooth during curing of composite restorations. The data was analyzed by one-way analysis of variance (ANOVA), Wilcoxon test, Kruskal-Wallis test, and Pearson's χ 2. After ANOVA, the Bonferroni multiple comparison test was performed. Results. Polymerization data analysis showed that in the pulp chamber temperature increase was higher than that without resin. Starlight PRO, in the same condition of Valo lamp, showed a lower temperature increase in pre- and intrapolymerization. A control group (without composite resin) was evaluated. Significance. Temperature increase during resin curing is a function of the rate of polymerization, due to the exothermic polymerization reaction, the energy from the light unit, and time of exposure. PMID:27195282

  19. Does the light source affect the repairability of composite resins?

    PubMed

    Karaman, Emel; Gönülol, Nihan

    2014-01-01

    The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin--Filtek Silorane, Filtek Z550 (3M ESPE), Gradia Direct Anterior (GC), and Aelite Posterior (BISCO)--were prepared and light-cured with a QTH light curing unit (LCU). The specimens were aged by thermal cycling and divided into three subgroups according to the light source used--QTH, LED, or PAC (n = 10). They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray). The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  20. LED Curing Lights and Temperature Changes in Different Tooth Sites.

    PubMed

    Armellin, E; Bovesecchi, G; Coppa, P; Pasquantonio, G; Cerroni, L

    2016-01-01

    Objectives. The aim of this in vitro study was to assess thermal changes on tooth tissues during light exposure using two different LED curing units. The hypothesis was that no temperature increase could be detected within the dental pulp during polymerization irrespective of the use of a composite resin or a light-curing unit. Methods. Caries-free human first molars were selected, pulp residues were removed after root resection, and four calibrated type-J thermocouples were positioned. Two LED lamps were tested; temperature measurements were made on intact teeth and on the same tooth during curing of composite restorations. The data was analyzed by one-way analysis of variance (ANOVA), Wilcoxon test, Kruskal-Wallis test, and Pearson's χ (2). After ANOVA, the Bonferroni multiple comparison test was performed. Results. Polymerization data analysis showed that in the pulp chamber temperature increase was higher than that without resin. Starlight PRO, in the same condition of Valo lamp, showed a lower temperature increase in pre- and intrapolymerization. A control group (without composite resin) was evaluated. Significance. Temperature increase during resin curing is a function of the rate of polymerization, due to the exothermic polymerization reaction, the energy from the light unit, and time of exposure.

  1. Effect of LED and Argon Laser on Degree of Conversion and Temperature Rise of Hybrid and Low Shrinkage Composite Resins

    PubMed Central

    Pahlevan, Ayob; Tabatabaei, Masumeh Hasani; Arami, Sakineh; Valizadeh, Sara

    2016-01-01

    Objectives: Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights. Materials and Methods: DC was measured using FTIR spectroscopy. For measuring temperature rise, composite resin samples were placed in Teflon molds and cured from the top. The thermocouple under samples recorded the temperature rise. After initial radiation and specimens reaching the ambient temperature, reirradiation was done and temperature was recorded again. Both temperature rise and DC data submitted to one-way ANOVA and Tukey-HSD tests (5% significance). Results: The obtained results revealed that DC was not significantly different between the understudy composite resins or curing units. Low shrinkage composite resin showed a significantly higher temperature rise than hybrid composite resin. Argon laser caused the lowest temperature rise among the curing units. Conclusion: Energy density of light curing units was correlated with the DC. Type of composite resin and light curing unit had a significant effect on temperature rise due to polymerization and curing unit, respectively. PMID:27843507

  2. Effect of LED and Argon Laser on Degree of Conversion and Temperature Rise of Hybrid and Low Shrinkage Composite Resins.

    PubMed

    Pahlevan, Ayob; Tabatabaei, Masumeh Hasani; Arami, Sakineh; Valizadeh, Sara

    2016-01-01

    Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights. DC was measured using FTIR spectroscopy. For measuring temperature rise, composite resin samples were placed in Teflon molds and cured from the top. The thermocouple under samples recorded the temperature rise. After initial radiation and specimens reaching the ambient temperature, reirradiation was done and temperature was recorded again. Both temperature rise and DC data submitted to one-way ANOVA and Tukey-HSD tests (5% significance). The obtained results revealed that DC was not significantly different between the understudy composite resins or curing units. Low shrinkage composite resin showed a significantly higher temperature rise than hybrid composite resin. Argon laser caused the lowest temperature rise among the curing units. Energy density of light curing units was correlated with the DC. Type of composite resin and light curing unit had a significant effect on temperature rise due to polymerization and curing unit, respectively.

  3. Effect of radiation light characteristics on surface hardness of paint-on resin for shade modification.

    PubMed

    Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Ban, Seiji

    2005-12-01

    The purpose of this study was to investigate the effect of radiation light characteristics--of different types of clinical light-curing unit--on polymerization efficiency, as determined by the surface hardness of light-cured paint-on resins. Four shades of paint-on resin for shade modification of restorative resins were used. Materials were cured using one laboratory and three clinical light-curing units with different light sources, namely tungsten-halogen, LED, plasma arc, and xenon flash lamps. Knoop hardness measurements were taken at both the top and bottom surfaces of the specimens to assess the mechanical properties and degree of polymerization. Both LED and plasma arc light units caused significantly poorer surface hardness than the halogen and laboratory xenon lights. In addition, the transparent shade was more sensitive to surface hardness than other chromatic shades. Our results indicated that the polymerization efficiency of paint-on resin was significantly influenced by the radiation light characteristics of clinical light-curing units.

  4. Optical multidimensional multiple access(O-MDMA): a new concept for free-space laser communication based on photonic mixer devices

    NASA Astrophysics Data System (ADS)

    Hess, Holger; Albrecht, Martin; Grothof, Markus; Hussmann, Stephan; Schwarte, Rudolf

    2004-01-01

    Working on optical distance measurement a new optical correlator was developed at the Institute for Data Processing of the University of Siegen in the last years. The so called Photonic Mixer Device (PMD), to be meant originally for laser ranging systems, offers a lot of advantages for wireless optical data communication like high speed spatial light demodulation up to the GHz range and inherent backlight suppression. This contribution describes the application of such PMDs in a free space interconnect based on the principle of Multi Dimensional Multiple Access (MDMA) and the advantages of this new approach, starting from the MDMA principle and followed by the fundamental functionality of PMDs. After that an Optical MDMA (O-MDMA) demonstrator and first measurement results will be presented.

  5. Talbot-Lau x-ray deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valdivia, M. P., E-mail: mpvaldivia@pha.jhu.edu; Stutman, D.; Stoeckl, C.

    2016-11-15

    Talbot-Lau X-ray deflectometry (TXD) has been developed as an electron density diagnostic for High Energy Density (HED) plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping were demonstrated for 25–29 J, 8–30 ps laser pulses using copper foil targets. Moiré pattern formation and grating survival were also observed using a copper x-pinch driven at 400 kA, ∼1 kA/ns. These results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

  6. Counterpropagating Radiative Shock Experiments on the Orion Laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki-Vidal, F.; Clayson, T.; Stehlé, C.

    We present new experiments to study the formation of radiative shocks and the interaction between two counterpropagating radiative shocks. The experiments are performed at the Orion laser facility, which is used to drive shocks in xenon inside large aspect ratio gas cells. The collision between the two shocks and their respective radiative precursors, combined with the formation of inherently three-dimensional shocks, provides a novel platform particularly suited for the benchmarking of numerical codes. The dynamics of the shocks before and after the collision are investigated using point-projection x-ray backlighting while, simultaneously, the electron density in the radiative precursor was measuredmore » via optical laser interferometry. Modeling of the experiments using the 2D radiation hydrodynamic codes nym and petra shows very good agreement with the experimental results.« less

  7. Design of Initial Opacity Platform at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Heeter, R. F.; Ahmed, M. F.; Ayers, S. L.; Emig, J. A.; Iglesias, C. A.; Liedahl, D. A.; Schneider, M. B.; Wilson, B. G.; Huffman, E. J.; King, J. A.; Opachich, Y. P.; Ross, P. W.; Bailey, J. E.; Rochau, G. A.; Craxton, R. S.; Garcia, E. M.; McKenty, P. W.; Zhang, R.; Cardenas, T.; Devolder, B. G.; Dodd, E. S.; Kline, J. L.; Sherrill, M. E.; Perry, T. S.

    2016-10-01

    The absorption and re-emission of x-rays by partly stripped ions plays a critical role in stars and in many laboratory plasmas. A NIF Opacity Platform has been designed to resolve a persistent disagreement between theory and experiments on the Sandia Z facility, studying iron in conditions closely related to the solar radiation-convection transition boundary. A laser heated hohlraum ``oven'' will produce iron plasmas at temperatures >150 eV and electron densities >=7x1021/cm3, and be probed with continuum X-rays from a capsule implosion backlighter source. The resulting X-ray transmission spectra will be recorded on a specially designed Opacity Spectrometer. This work was performed under the auspices of the U.S. Department of Energy by LLNL under Contract DE-AC52-07NA27344.

  8. Closer Look: Majestic Mountains and Frozen Plains

    NASA Image and Video Library

    2015-09-17

    Just 15 minutes after its closest approach to Pluto on July 14, 2015, NASA's New Horizons spacecraft looked back toward the sun and captured a near-sunset view of the rugged, icy mountains and flat ice plains extending to Pluto's horizon. The smooth expanse of the informally named Sputnik Planum (right) is flanked to the west (left) by rugged mountains up to 11,000 feet (3,500 meters) high, including the informally named Norgay Montes in the foreground and Hillary Montes on the skyline. The backlighting highlights more than a dozen layers of haze in Pluto's tenuous but distended atmosphere. The image was taken from a distance of 11,000 miles (18,000 kilometers) to Pluto; the scene is 230 miles (380 kilometers) across. http://photojournal.jpl.nasa.gov/catalog/PIA19947

  9. A comparison of hydro-instabilities in CH, HDC, and beryllium ablators on NIF

    NASA Astrophysics Data System (ADS)

    Smalyuk, V. A.; Robey, H. F.; Ali, S.; Berzak Hopkins, L. F.; Casey, D. T.; Celliers, P. M.; Clark, D. S.; Felker, S. J.; Field, J. E.; Haan, S. W.; Hammel, B. A.; Hsing, W. W.; Kroll, J. J.; Landen, O. L.; Lepape, S.; Macphee, A. G.; Martinez, D.; Milovich, J.; Nikroo, A.; Pickworth, L.; Stadermann, M.; Weber, C. R.; Kline, J.; Loomis, E.; Yi, A.

    2017-10-01

    A comparison of the hydrodynamic growth in plastic, high-density carbon, and beryllium ablators will be presented in indirect-drive implosions on National Ignition Facility. This comparison is based on experimentally measured instabilities in all phases of implosions for the three ablators. The 2-D and 3-D perturbations were measured at the ablation-surface with the Hydrodynamic Growth Radiography platform. In the deceleration phase of implosions, innovative self-emission and ``self-backlight'' techniques were used. Results of the 3-D perturbation growth including engineering features will also be presented for convergence up to 20 and compared for the three ablators. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  10. Switching of liquid crystal devices between reflective and transmissive modes

    NASA Astrophysics Data System (ADS)

    Lin, Hui-Chi; Wang, Chih-Hung

    Transflective liquid crystal displays (LCD) are commonly known that each pixel is divided into reflective (R) and transmissive (T) subpixels. The R mode uses ambient light, while the T mode utilizes a backlight to display images. However, the division of the pixel decreases the light efficiency and the resolution. This study demonstrates a gelator-doped liquid crystal (LC) devices, that is switchable between R and T modes, without sub-pixel division. The R and T modes are designed to have bend configurations with phase retardation of π/2 and π, respectively. The phase retardation of a LC device can be varied and fixed by the thermoreversible association and dissociation of the gelator molecules. It is believed that the proposed device is a potential candidate for portable information systems.

  11. Proton Radiography of Spontaneous Fields, Plasma Flows and Dynamics in X-Ray Driven Inertial-Confinement Fusion Implosions

    NASA Astrophysics Data System (ADS)

    Li, C. K.; Seguin, F. H.; Frenje, J. A.; Rosenberg, M.; Zylstra, A. B.; Rinderknecht, H. G.; Petrasso, R. D.; Amendt, P. A.; Landen, O. L.; Town, R. P. J.; Betti, R.; Knauer, J. P.; Meyerhofer, D. D.; Back, C. A.; Kilkenny, J. D.; Nikroo, A.

    2010-11-01

    Backlighting of x-ray-driven implosions in empty hohlraums with mono-energetic protons on the OMEGA laser facility has allowed a number of important phenomena to be observed. Several critical parameters were determined, including plasma flow, three types of spontaneous electric fields and megaGauss magnetic fields. These results provide insight into important issues in indirect-drive ICF. Even though the cavity is effectively a Faraday cage, the strong, local fields inside the hohlraum can affect laser-plasma instabilities, electron distributions and implosion symmetry. They are of fundamental scientific importance for a range of new experiments at the frontiers of high-energy-density physics. Future experiments designed to characterize the field formation and evolution in low-Z gas fill hohlraums will be discussed.

  12. Counterpropagating Radiative Shock Experiments on the Orion Laser.

    PubMed

    Suzuki-Vidal, F; Clayson, T; Stehlé, C; Swadling, G F; Foster, J M; Skidmore, J; Graham, P; Burdiak, G C; Lebedev, S V; Chaulagain, U; Singh, R L; Gumbrell, E T; Patankar, S; Spindloe, C; Larour, J; Kozlova, M; Rodriguez, R; Gil, J M; Espinosa, G; Velarde, P; Danson, C

    2017-08-04

    We present new experiments to study the formation of radiative shocks and the interaction between two counterpropagating radiative shocks. The experiments are performed at the Orion laser facility, which is used to drive shocks in xenon inside large aspect ratio gas cells. The collision between the two shocks and their respective radiative precursors, combined with the formation of inherently three-dimensional shocks, provides a novel platform particularly suited for the benchmarking of numerical codes. The dynamics of the shocks before and after the collision are investigated using point-projection x-ray backlighting while, simultaneously, the electron density in the radiative precursor was measured via optical laser interferometry. Modeling of the experiments using the 2D radiation hydrodynamic codes nym and petra shows very good agreement with the experimental results.

  13. Xenia Mission: Spacecraft Design Concept

    NASA Technical Reports Server (NTRS)

    Hopkins, R. C.; Johnson, C. L.; Kouveliotou, C.; Jones, D.; Baysinger, M.; Bedsole, T.; Maples, C. C.; Benfield, P. J.; Turner, M.; Capizzo, P.; hide

    2009-01-01

    The proposed Xenia mission will, for the first time, chart the chemical and dynamical state of the majority of baryonic matter in the universe. using high-resolution spectroscopy, Xenia will collect essential information from major traces of the formation and evolution of structures from the early universe to the present time. The mission is based on innovative instrumental and observational approaches: observing with fast reaction gamma-ray bursts (GRBs) with a high spectral resolution. This enables the study of their (star-forming) environment from the dark to the local universe and the use of GRBs as backlight of large-scale cosmological structures, observing and surveying extended sources with high sensitivity using two wide field-of-view x-ray telescopes - one with a high angular resolution and the other with a high spectral resolution.

  14. Counterpropagating Radiative Shock Experiments on the Orion Laser

    DOE PAGES

    Suzuki-Vidal, F.; Clayson, T.; Stehlé, C.; ...

    2017-08-02

    We present new experiments to study the formation of radiative shocks and the interaction between two counterpropagating radiative shocks. The experiments are performed at the Orion laser facility, which is used to drive shocks in xenon inside large aspect ratio gas cells. The collision between the two shocks and their respective radiative precursors, combined with the formation of inherently three-dimensional shocks, provides a novel platform particularly suited for the benchmarking of numerical codes. The dynamics of the shocks before and after the collision are investigated using point-projection x-ray backlighting while, simultaneously, the electron density in the radiative precursor was measuredmore » via optical laser interferometry. Modeling of the experiments using the 2D radiation hydrodynamic codes nym and petra shows very good agreement with the experimental results.« less

  15. Field lens multiplexing in holographic 3D displays by using Bragg diffraction based volume gratings

    NASA Astrophysics Data System (ADS)

    Fütterer, G.

    2016-11-01

    Applications, which can profit from holographic 3D displays, are the visualization of 3D data, computer-integrated manufacturing, 3D teleconferencing and mobile infotainment. However, one problem of holographic 3D displays, which are e.g. based on space bandwidth limited reconstruction of wave segments, is to realize a small form factor. Another problem is to provide a reasonable large volume for the user placement, which means to provide an acceptable freedom of movement. Both problems should be solved without decreasing the image quality of virtual and real object points, which are generated within the 3D display volume. A diffractive optical design using thick hologram gratings, which can be referred to as Bragg diffraction based volume gratings, can provide a small form factor and high definition natural viewing experience of 3D objects. A large collimated wave can be provided by an anamorphic backlight unit. The complex valued spatial light modulator add local curvatures to the wave field he is illuminated with. The modulated wave field is focused onto to the user plane by using a volume grating based field lens. Active type liquid crystal gratings provide 1D fine tracking of approximately +/- 8° deg. Diffractive multiplex has to be implemented for each color and for a set of focus functions providing coarse tracking. Boundary conditions of the diffractive multiplexing are explained. This is done in regards to the display layout and by using the coupled wave theory (CWT). Aspects of diffractive cross talk and its suppression will be discussed including longitudinal apodized volume gratings.

  16. Unique and proforma birth plans: a qualitative exploration of midwives׳ experiences.

    PubMed

    Welsh, Joanne V; Symon, Andrew G

    2014-07-01

    birth plans detailing a woman׳s preferences for intrapartum care are a common feature in British maternity units, and are a means of encouraging the implementation of choice. Proforma versions may be incorporated routinely in antenatal case notes, or the woman may devise her own unique birth plan. Although women׳s views of birth plans have been explored, the views of midwives have not to date been evaluated. The growth of midwife-led units in the UK has highlighted different philosophies of care, some of which can be reflected in the different types of birth plan. Given the increasingly diverse nature of UK midwifery workplaces we set out to explore and compare the experience of midwives working in midwife-led and obstetric-led settings in relation to unique and proforma birth plans. qualitative study using focus groups of midwives in a midwife-led unit (MLU; n=5) and obstetric-led unit (OLU; n=4) in the East of England. We used an interpretative phenomenological analytical approach. three main themes arose from the data. Firstly, the term 'birth plan' can be misleading, and was criticised for encouraging the belief that birth can be 'planned'. In addition, midwives claimed that 'unique' birth plans, especially those influenced by some consumer advocacy groups, are becoming standardised in their rejection of policies and procedures and requests for intervention-free birth. Secondly, birth plans were a source of irritation for midwives in both groups, although the cause of the irritation differed between groups. Finally, it was found that midwives in both groups felt that birth plans put pressure on them, although again, the source of the pressure, and therefore the way in which midwives reacted to this pressure, differed between groups. the term 'birth plan' can be misleading and create false expectations. If 'unique' birth plans are becoming 'standardised' in the sense that they routinely request the same things, they are little different to proforma birth plans. Some midwives perceive pressure both from women and the wider multidisciplinary team as a result of birth plans, a perception that causes some irritation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Visual function assessment in simulated real-life situations in patients with age-related macular degeneration compared to normal subjects.

    PubMed

    Barteselli, G; Gomez, M L; Doede, A L; Chhablani, J; Gutstein, W; Bartsch, D-U; Dustin, L; Azen, S P; Freeman, W R

    2014-10-01

    To evaluate visual function variations in eyes with age-related macular degeneration (AMD) compared to normal eyes under different light/contrast conditions using a time-dependent visual acuity testing instrument, the Central Vision Analyzer (CVA). Overall, 37 AMD eyes and 35 normal eyes were consecutively tested with the CVA after assessing best-corrected visual acuity (BCVA) using ETDRS charts. The CVA established visual thresholds for three mesopic environments (M1 (high contrast), M2 (medium contrast), and M3 (low contrast)) and three backlight-glare environments (G1 (high contrast, equivalent to ETDRS), G2 (medium contrast), and G3 (low contrast)) under timed conditions. Vision drop across environments was calculated, and repeatability of visual scores was determined. BCVA significantly reduced with decreasing contrast in all eyes. M1 scores for BCVA were greater than M2 and M3 (P<0.001); G1 scores were greater than G2 and G3 (P<0.01). BCVA dropped more in AMD eyes than in normal eyes between M1 and M2 (P=0.002) and between M1 and M3 (P=0.003). In AMD eyes, BCVA was better using ETDRS charts compared to G1 (P<0.001). The drop in visual function between ETDRS and G1 was greater in AMD eyes compared to normal eyes (P=0.004). Standard deviations of test-retest ranged from 0.100 to 0.139 logMAR. The CVA allowed analysis of the visual complaints that AMD patients experience with different lighting/contrast time-dependent conditions. BCVA changed significantly under different lighting/contrast conditions in all eyes, however, AMD eyes were more affected by contrast reduction than normal eyes. In AMD eyes, timed conditions using the CVA led to worse BCVA compared to non-timed ETDRS charts.

  18. A passive cooling system proposal for multifunction and high-power displays

    NASA Astrophysics Data System (ADS)

    Tari, Ilker

    2013-03-01

    Flat panel displays are conventionally cooled by internal natural convection, which constrains the possible rate of heat transfer from the panel. On one hand, during the last few years, the power consumption and the related cooling requirement for 1080p displays have decreased mostly due to energy savings by the switch to LED backlighting and more efficient electronics. However, on the other hand, the required cooling rate recently started to increase with new directions in the industry such as 3D displays, and ultra-high-resolution displays (recent 4K announcements and planned introduction of 8K). In addition to these trends in display technology itself, there is also a trend to integrate consumer entertainment products into displays with the ultimate goal of designing a multifunction device replacing the TV, the media player, the PC, the game console and the sound system. Considering the increasing power requirement for higher fidelity in video processing, these multifunction devices tend to generate very high heat fluxes, which are impossible to dissipate with internal natural convection. In order to overcome this obstacle, instead of active cooling with forced convection that comes with drawbacks of noise, additional power consumption, and reduced reliability, a passive cooling system relying on external natural convection and radiation is proposed here. The proposed cooling system consists of a heat spreader flat heat pipe and aluminum plate-finned heat sink with anodized surfaces. For this system, the possible maximum heat dissipation rates from the standard size panels (in 26-70 inch range) are estimated by using our recently obtained heat transfer correlations for the natural convection from aluminum plate-finned heat sinks together with the surface-to-surface radiation. With the use of the proposed passive cooling system, the possibility of dissipating very high heat rates is demonstrated, hinting a promising green alternative to active cooling.

  19. 77 FR 17569 - United States-Canada Regulatory Cooperation Council (RCC)-Transportation-Dangerous Goods Working...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ... identified in the Joint Action Plan, the Transportation--Dangerous Goods Working Group led by senior...)-- Transportation--Dangerous Goods Working Group AGENCY: Pipeline and Hazardous Materials Safety Administration...--Dangerous Goods Working Group, of the United States-Canada Regulatory Cooperation Council (RCC). Comments...

  20. Intern Abstract for Spring 2016

    NASA Technical Reports Server (NTRS)

    Gibson, William

    2016-01-01

    The Human Interface Branch - EV3 - is evaluating Organic lighting-emitting diodes (OLEDs) as an upgrade for current displays on future spacecraft. OLEDs have many advantages over current displays. Conventional displays require constant backlighting which draws a lot of power, but with OLEDs they generate light themselves. OLEDs are lighter, and weight is always a concern with space launches. OLEDs also grant greater viewing angles. OLEDs have been in the commercial market for almost ten years now. What is not known is how they will perform in a space-like environment; specifically deep space far away from the Earth's magnetosphere. In this environment, the OLEDs can be expected to experience vacuum and galactic radiation. The intern's responsibility has been to prepare the OLED for a battery of tests. Unfortunately, it will not be ready for testing at the end of the internship. That being said much progress has been made: a) Developed procedures to safely disassemble the tablet. b) Inventoried and identified critical electronic components. c) 3D printed a testing apparatus. d) Wrote software in Python that will test the OLED screen while being radiated. e) Built circuits to restart the tablet and the test pattern, and ensure it doesn't fall asleep during radiation testing. f) Built enclosure that will house all of the electronics Also, the intern has been working on a way to take messages from a simulated Caution and Warnings system, process said messages into packets, send audio packets to a multicast address that audio boxes are listening to, and output spoken audio. Currently, Cautions and Warnings use a tone to alert crew members of a situation, and then crew members have to read through their checklists to determine what the tone means. In urgent situations, EV3 wants to deliver concise and specific alerts to the crew to facilitate any mitigation efforts on their part. Significant progress was made on this project: a) Open channel with the simulated Caution and Warning system to acquire messages. b) Configure audio boxes. c) Grab pre-recorded audio files. d) Packetize the audio stream. A third project that was assigned to implement LED indicator modules for an Omnibus project. The Omnibus project is investigating better ways designing lighting for the interior of spacecraft-both spacecraft lighting and avionics box status lighting indication. The current scheme contains too much of the blue light spectrum that disrupts the sleep cycle. The LED indicator modules are to simulate the indicators running on a spacecraft. Lighting data will be gathered by human factors personal and use in a model underdevelopment to model spacecraft lighting. Significant progress was made on this project: Designed circuit layout a) Tested LEDs at LETF. b) Created GUI for the indicators. c) Created code for the Arduino to run that will illuminate the indicator modules.

  1. Can Medical Students Teach? A Near-Peer-Led Teaching Program for "Year 1" Students

    ERIC Educational Resources Information Center

    Jackson, T. A.; Evans, D. J. R.

    2012-01-01

    The General Medical Council states that United Kingdom graduates must function effectively as educators. There is a growing body of evidence showing that medical students can be included as teachers within a medical curriculum. Our aim was to design and implement a near-peer-led teaching program in an undergraduate medical curriculum and assess…

  2. Application of blue laser diodes and LEDs in phototherapy for neonatal jaundice

    NASA Astrophysics Data System (ADS)

    Hamza, Mostafa; Sayed El-Ahl, Mohammad H.; Hamza, Ahmad M.; Hamza, Aya M.; Hamza, Yahya M.

    2003-10-01

    The authors introduce the design of a compact phototherapy unit capable of fulfilling the recommendations of the clinical use of lasers and LEDs in phototherapy for the treatment of neonatal jaundice. The system keeps the duration of phototherapy to the minimum required for efficient treatment. Our leading clinical experience as well as the wavelength selection rules will be presented.

  3. Instructor Influence on Student Intercultural Gains and Learning during Instructor-Led, Short-Term Study Abroad

    ERIC Educational Resources Information Center

    Anderson, Christine L.; Lorenz, Karl; White, Michael

    2016-01-01

    In the United States post 9/11, there is increasing interest by the government and by institutions of higher education in educating students and citizens to more successfully navigate difference and interact in an increasingly connected world. This has led to a rise in the number of U.S. American students studying abroad especially on…

  4. BiliLED low cost neonatal phototherapy, from prototype to industry

    NASA Astrophysics Data System (ADS)

    Geido, Daniel; Failache, Horacio; Simini, Franco

    2007-11-01

    BiliLED is a phototherapy instrument designed to reduce bilirrubin blood rates in new born babies with jaundice. The light source is centred at 470 nm with a bandwidth of 35 nm and includes a matrix of 196 (14×14) InGaN LEDs. The optical elements are designed to maximize the light intensity useful for treatment, with a small number of LEDs in a compact and low cost unit. The optic array is such that every LED illuminates all the treatment area, which ensures redundancy and, thus, a high reliability not to be found in single-lamp instruments. Thermal dissipation and cost of BiliLED are both an order-of-magnitude smaller than conventional therapy lamps. BiliLED adjusts coetaneous irradiation with a feedback loop to compensate the loss or aging of LEDs achieving a calibrated light source for over a decade of use. A clinical trial in 20 hyperbilirrubinaemia patients shows 16% bilirrubin degradation within 24 hours of treatment, higher than most lamp phototherapy instruments. The steps from prototype to commercial model are described.

  5. The Increasing Importance of Deposition of Reduced Nitrogen in the United States

    EPA Science Inventory

    Rapid development of agricultural activities and fossil fuel combustion in the United States has led to a great increase in reactive nitrogen (Nr) emissions in the second half of the twentieth century. These emissions have been linked to excess nitrogen (N) deposition (i.e. depos...

  6. Leading Professional Learning to Develop Professional Capital: The Saskatchewan Professional Development Unit's Facilitator Community

    ERIC Educational Resources Information Center

    Osmond-Johnson, Pamela

    2017-01-01

    Drawing on data from a mixed methods study of the Saskatchewan Professional Development Unit's (SPDU) Facilitator Community, this paper highlights the potential of teacher-led professional learning in developing professional capital through engagement in teacher leadership. Analysis of survey, interview, and observational data revealed the…

  7. Increasing plant density in eastern United States broccoli production systems to maximize marketable head yields

    USDA-ARS?s Scientific Manuscript database

    Increased demand for fresh market broccoli (Brassica oleracea L. var. italica) has led to increased production along the eastern seaboard of the United States. Maximizing broccoli yields is a primary concern for quickly expanding eastern commercial markets. Thus, a plant density study was carried ...

  8. Rehabilitation Technology for the Blind in the United States.

    ERIC Educational Resources Information Center

    Jacobson, William H.

    Research in the United States and abroad has led to advances in rehabilitation technology that enables blind and visually impaired persons to compete with sighted persons for employment. Relatively inexpensive devices such as pocket calculators, transistor radios, cassette recorders, and digital watches have become aids for the blind; some…

  9. The andean ophiolitic megastructures on the Buga-Buenaventura transverse (Western Cordillera—Valle Colombia)

    NASA Astrophysics Data System (ADS)

    Bourgois, Jacques; Calle, Bernardo; Tournon, Jean; Toussaint, Jean-François

    1982-02-01

    A structural study of the Buga-Buenaventura transverse in the central part of the Western Cordillera of Colombia, has shown the presence of three structural units which, from bottom to top and from west to east, are: the Rio Dagua unit, the Rio Calima unit, and the Loboguerrero window unit. All three units comprise strata between 120 and 80 m.y. old overlying a basement of green rocks showing the characteristics of submarine flows. The Bolivar ultrabasic and basic massif is geographically linked to the Rio Calima unit, in which green rocks predominate, and is separated from it by a tectonic contact. The upper part of the massif, on the other hand, shows high-temperature metamorphic rocks formed during its emplacement. The Rio Dagua unit shows two tectonic phases with isoclinal folding and development of schistosity. The first phase is contemporaneous with low-grade metamorphism equivalent to lower greenschist facies conditions. The Loboguerrero window unit shows a large recumbent fold oriented towards the southeast. Deformation in the Rio Calima unit is weaker and appears to correspond to a higher structural level than in the two other units. As the attitudes of the S1, schistosity in the Rio Dagua unit and of the shear zones located at the green rocks-sediments contact in this same unit are similar to that of the overthrust at the base of the Rio Calima unit, we are led to postulate that the overthrust belongs to the first phase of deformation, as also does the recumbent fold in the Loboguerrero window unit. We are thus led to propose a southeastward direction of emplacement for the nappes in the Western Cordillera of Colombia. In conclusion, the authors extend their observations and propose a new structural interpretation of the "Occidente Colombiano".

  10. Compact submicrosecond, high current generator for wire explosion experiments

    NASA Astrophysics Data System (ADS)

    Aranchuk, L. E.; Chuvatin, A. S.; Larour, J.

    2004-01-01

    The PIAF generator was designed for low total energy and high energy density experiments with liners, X-pinch or fiber Z-pinch loads. These studies are of interest for such applications as surface and material science, microscopy of biological specimens, lithography of x-ray sensitive resists, and x-ray backlighting of pulsed-power plasmas. The generator is based on an RLC circuit that includes six NWL 180 nF-50 kV capacitors that store up to 1.3 kJ. The capacitors are connected in parallel to a single multispark switch designed to operate at atmospheric pressure. The switch allows reaching a time delay between the trigger pulse and the current pulse of less than 80 ns and has jitter of 6 ns. The total inductance without a load compartment was optimized to be as low as 16 nH, which leads to extremely low impedance of ˜0.12 Ω. A 40 kV initial voltage provides 250 kA maximum current in a 6 nH inductive load with a 180 ns current rise time. PIAF has dimensions of 660×660×490 mm and weight of less than 100 kg, thus manifesting itself as robust, simple to operate, and cost effective. A description of the PIAF generator and the initial experimental results on PIAF with an X-pinch type load are reported. The generator was demonstrated to operate successfully with an X-pinch type load. The experiments first started with investigation of the previously unexplored X-pinch conduction time range, 100 ns-1 μs. A single short radiation pulse was obtained that came from a small, point-like plasma. The following x-ray source characteristics were achieved: typical hot spot size of 50-100 μm, radiation pulse duration of 1.5-2 ns, and radiation yield of about 250-500 mJ in the softer spectral range (hν⩾700 eV) and 50-100 mJ in the harder one (hν⩾1 keV). These results provide the potential for further application of this source, such as use as a backlight diagnostic tool.

  11. Fundamental Characteristics of Deep-UV Light-Emitting Diodes and Their Application To Control Foodborne Pathogens

    PubMed Central

    Shin, Joo-Yeon; Kim, Soo-Ji; Kim, Do-Kyun

    2015-01-01

    Low-pressure mercury UV (LP-UV) lamps have long been used for bacterial inactivation, but due to certain disadvantages, such as the possibility of mercury leakage, deep-UV-C light-emitting diodes (DUV-LEDs) for disinfection have recently been of great interest as an alternative. Therefore, in this study, we examined the basic spectral properties of DUV-LEDs and the effects of UV-C irradiation for inactivating foodborne pathogens, including Escherichia coli O157:H7, Salmonella enterica serovar Typhimurium, and Listeria monocytogenes, on solid media, as well as in water. As the temperature increased, DUV-LED light intensity decreased slightly, whereas LP-UV lamps showed increasing intensity until they reached a peak at around 30°C. As the irradiation dosage and temperature increased, E. coli O157:H7 and S. Typhimurium experienced 5- to 6-log-unit reductions. L. monocytogenes was reduced by over 5 log units at a dose of 1.67 mJ/cm2. At 90% relative humidity (RH), only E. coli O157:H7 experienced inactivation significantly greater than at 30 and 60% RH. In a water treatment study involving a continuous system, 6.38-, 5.81-, and 3.47-log-unit reductions were achieved in E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively, at 0.5 liter per minute (LPM) and 200 mW output power. The results of this study suggest that the use of DUV-LEDs may compensate for the drawbacks of using LP-UV lamps to inactivate foodborne pathogens. PMID:26162872

  12. A U.S. Forest Service special forest products appraisal system: background, methods, and assessment.

    Treesearch

    Jerry Smith; Lisa K. Crone; Susan J. Alexander

    2010-01-01

    Increasing concern over the management and harvest of special forest products (SFP) from national forest lands has led to the development of new Forest Service policy directives. In this paper, we present a brief history of SFPs in the Western United States, highlighting the issues that necessitated new management direction. The new policy directives that led to the...

  13. Evaluating the outcomes of a podiatry-led assessment service in a public hospital orthopaedic unit.

    PubMed

    Bonanno, Daniel R; Medica, Virginia G; Tan, Daphne S; Spring, Anita A; Bird, Adam R; Gazarek, Jana

    2014-01-01

    In Australia, the demand for foot and ankle orthopaedic services in public health settings currently outweighs capacity. Introducing experienced allied health professionals into orthopaedic units to initiate the triage, assessment and management of patients has been proposed to help meet demand. The aim of this study was to evaluate the effect of introducing a podiatry-led assessment service in a public hospital orthopaedic unit. The outcomes of interest were determining: the proportion of patients discharged without requiring an orthopaedic appointment, agreement in diagnosis between the patient referral and the assessing podiatrist, the proportion of foot and ankle conditions presenting to the service, and the proportion of each condition to require an orthopaedic appointment. This study audited the first 100 patients to receive an appointment at a new podiatry-led assessment service. The podiatrist triaged 'Category 3' referrals consisting of musculoskeletal foot and ankle conditions and appointments were provided for those considered likely to benefit from non-surgical management. Following assessment, patients were referred to an appropriate healthcare professional or were discharged. At the initial appointment or following a period of care, patients were discharged if non-surgical management was successful, surgery was not indicated, patients did not want surgery, and if patient's failed to attend their appointments. All other patients were referred for an orthopaedic consultation as indicated. Ninety-five of the 100 patients (69 females and 31 males; mean age 51.9, SD 16.4 years) attended their appointment at the podiatry-led assessment service. The 95 referrals contained a total of 107 diagnoses, of which the podiatrist agreed with the diagnosis stated on the referral in 56 cases (Kappa =0.49, SE = 0.05). Overall, 34 of the 100 patients were referred to an orthopaedic surgeon and the remaining 66 patients were discharged from the orthopaedic waiting list without requiring an orthopaedic consultation. Two-thirds of patients who had an appointment at the podiatry-led assessment service were discharged without requiring a surgical consultation. The introduction of a podiatry-led service assists with timely provision of patient care and ensures those with the greatest need for orthopaedic surgery have improved access to specialist care.

  14. Effect of light energy density on conversion degree and hardness of dual-cured resin cement.

    PubMed

    Komori, Paula Carolina de Paiva; de Paula, Andréia Bolzan; Martin, Airton Abrāo; Tango, Rubens Nisie; Sinhoreti, Mario Alexandre Coelho; Correr-Sobrinho, Lourenço

    2010-01-01

    This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm x 5 mm) and covered with a Mylar strip. The tip of the light-curing unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37 degrees C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (alpha = 0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the light-curing unit and by its light energy density.

  15. Application of Wireless Intelligent Control System for HPS Lamps and LEDs Combined Illumination in Road Tunnel

    PubMed Central

    Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo

    2014-01-01

    Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266

  16. When "Best Value" May Not Quite Say What It Means: A Reflection on Measuring Quality in Public Services in the United Kingdom

    ERIC Educational Resources Information Center

    Trickey, Keith

    2003-01-01

    A review of the development of the United Kingdom obsession with "value for money", and the performance indicators that have led to the current "best value" approach that is working through the public sector in the United Kingdom. I hope to identify the values and problems with the approach offering a salutary warning to those…

  17. Light-emitting device test systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCord, Mark; Brodie, Alan; George, James

    Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

  18. Seed-to-seed growth of superdwarf wheat and arabidopsis using red light-emitting diodes (LED's): A report on baseline tests conducted for NASA's proposed Plant Research Unit (PRU)

    NASA Technical Reports Server (NTRS)

    Goins, G. D.; Yorio, N. C.; Sanwo, M. M.; Brown, C. S.

    1996-01-01

    To determine the influence of narrow-spectrum red light-emitting diodes (LED's) on plant growth and seed production, wheat (Triticum aestivum L.cv Superdwarf) and Arabidopsis (Arabidopsis thaliana (L.) Heynh, race Columbia) plants were grown under red LED's (peak emission 660 nm) and compared to plants grown under daylight fluorescent (white) light and red LED's supplemented with either 1 percent or 10 percent blue fluorescent (BF) light. Wheat growth under red LED's alone appeared normal, whereas Arabidopsis under red LED's alone developed curled leaf margins and a spiraling growth pattern. Both wheat and Arabidopsis under red LED's alone or red LED's + 1 percent BF light had significantly lower seed yield than plants grown under white light. However, the addition of 10 percent BF light to red LED's partially alleviated the adverse effect of red LED's on yield. Irrespective of the light treatment, viable seeds were produced by wheat(75-92 percent germination rate) and Arabidopsis (85-100 percent germination rate). These results indicate that wheat, and to a lesser extent Arabidopsis, can be successfully grown under red LED's alone, but supplemental blue light is required with red LED's to sufficiently match the growth characteristics and seed yield associated with plants grown under white light.

  19. Evaluating Maternity Units: a prospective cohort study of freestanding midwife-led primary maternity units in New Zealand-clinical outcomes.

    PubMed

    Grigg, Celia P; Tracy, Sally K; Tracy, Mark; Daellenbach, Rea; Kensington, Mary; Monk, Amy; Schmied, Virginia

    2017-08-29

    To compare maternal and neonatal birth outcomes and morbidities associated with the intention to give birth in a freestanding primary level midwife-led maternity unit (PMU) or tertiary level obstetric-led maternity hospital (TMH) in Canterbury, Aotearoa/New Zealand. Prospective cohort study. 407 women who intended to give birth in a PMU and 285 women who intended to give birth at the TMH in 2010-2011. All of the women planning a TMH birth were 'low risk', and 29 of the PMU cohort had identified risk factors. Mode of birth, Apgar score of less than 7 at 5 min and neonatal unit admission. labour onset, analgesia, blood loss, third stage of labour management, perineal trauma, non-pharmacological pain relief, neonatal resuscitation, breastfeeding, gestational age at birth, birth weight, severe morbidity and mortality. Women who planned a PMU birth were significantly more likely to have a spontaneous vaginal birth (77.9%vs62.3%, adjusted OR (AOR) 1.61, 95% CI 1.08 to 2.39), and significantly less likely to have an instrumental assisted vaginal birth (10.3%vs20.4%, AOR 0.59, 95% CI 0.37 to 0.93). The emergency and elective caesarean section rates were not significantly different (emergency: PMU 11.6% vs TMH 17.5%, AOR 0.88, 95% CI 0.55 to 1.40; elective: PMU 0.7% vs TMH 2.1%, AOR 0.34, 95% CI 0.08 to 1.41). There were no significant differences between the cohorts in rates of 5 min Apgar score of <7 (2.0%vs2.1%, AOR 0.82, 95% CI 0.27 to 2.52) and neonatal unit admission (5.9%vs4.9%, AOR 1.44, 95% CI 0.70 to 2.96). Planning to give birth in a primary unit was associated with similar or reduced odds of intrapartum interventions and similar odds of all measured neonatal well-being indicators. The results of this study support freestanding midwife-led primary-level maternity units as physically safe places for well women to plan to give birth, with these women having higher rates of spontaneous vaginal births and lower rates of interventions and their associated morbidities than those who planned a tertiary hospital birth, with no differences in neonatal outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Evaluating Maternity Units: a prospective cohort study of freestanding midwife-led primary maternity units in New Zealand—clinical outcomes

    PubMed Central

    Grigg, Celia P; Tracy, Sally K; Tracy, Mark; Daellenbach, Rea; Kensington, Mary; Monk, Amy; Schmied, Virginia

    2017-01-01

    Objective To compare maternal and neonatal birth outcomes and morbidities associated with the intention to give birth in a freestanding primary level midwife-led maternity unit (PMU) or tertiary level obstetric-led maternity hospital (TMH) in Canterbury, Aotearoa/New Zealand. Design Prospective cohort study. Participants 407 women who intended to give birth in a PMU and 285 women who intended to give birth at the TMH in 2010–2011. All of the women planning a TMH birth were ‘low risk’, and 29 of the PMU cohort had identified risk factors. Primary outcomes Mode of birth, Apgar score of less than 7 at 5 min and neonatal unit admission. Secondary outcomes: labour onset, analgesia, blood loss, third stage of labour management, perineal trauma, non-pharmacological pain relief, neonatal resuscitation, breastfeeding, gestational age at birth, birth weight, severe morbidity and mortality. Results Women who planned a PMU birth were significantly more likely to have a spontaneous vaginal birth (77.9%vs62.3%, adjusted OR (AOR) 1.61, 95% CI 1.08 to 2.39), and significantly less likely to have an instrumental assisted vaginal birth (10.3%vs20.4%, AOR 0.59, 95% CI 0.37 to 0.93). The emergency and elective caesarean section rates were not significantly different (emergency: PMU 11.6% vs TMH 17.5%, AOR 0.88, 95% CI 0.55 to 1.40; elective: PMU 0.7% vs TMH 2.1%, AOR 0.34, 95% CI 0.08 to 1.41). There were no significant differences between the cohorts in rates of 5 min Apgar score of <7 (2.0%vs2.1%, AOR 0.82, 95% CI 0.27 to 2.52) and neonatal unit admission (5.9%vs4.9%, AOR 1.44, 95% CI 0.70 to 2.96). Planning to give birth in a primary unit was associated with similar or reduced odds of intrapartum interventions and similar odds of all measured neonatal well-being indicators. Conclusions The results of this study support freestanding midwife-led primary-level maternity units as physically safe places for well women to plan to give birth, with these women having higher rates of spontaneous vaginal births and lower rates of interventions and their associated morbidities than those who planned a tertiary hospital birth, with no differences in neonatal outcomes. PMID:28851782

  1. Effects of Nitrogen Deposition and Empirical Nitrogen Critical Loads for Ecoregions of the United States

    EPA Science Inventory

    Human activity in the last century has led to a significant increase in nitrogen (N) emissions and atmospheric deposition. This N deposition has reached a level that has caused or is likely to cause alterations to the structure and function of many ecosystems across the United St...

  2. Inspection of fecal contamination on strawberries using line-scan led-induced fluorescence imaging techniques

    USDA-ARS?s Scientific Manuscript database

    In the United States, fecal contamination of produce is a food safety issue because illnesses caused by associated pathogens such as Escherichia coli and Salmonella. Outbreaks of foodborne illnesses associated with consuming raw fruits and vegetables in the United States continue to be a public heal...

  3. Park Forest Middle School STEM Education Fair 2010

    ERIC Educational Resources Information Center

    Hughes, Bill

    2010-01-01

    Innovations from the United States have often led the world to new discoveries and solutions to complex problems. However, there are alarming indications that the United States is falling behind other countries in the ability to apply science, technology, engineering, and math to complex problems facing our world. In order for the country to…

  4. Newspaper Suppression During the Mexican War, 1846-1848.

    ERIC Educational Resources Information Center

    Reilly, Tom

    A number of scholars have found that wartime conditions often bring about conflict between the press and the military. This study documents the various incidents between the United States Army and various Mexican and United States newspaper editors that led to at least ten cases of newspaper suppression, the occasional use of prior censorship, and…

  5. The Short Life and Ignominious Death of ALA Video and Special Projects.

    ERIC Educational Resources Information Center

    Handman, Gary

    1991-01-01

    Discussion of videocassettes in our culture and the function of video collections in libraries focuses on the creation and demise of a unit sponsored by the American Library Association, the ALA Video and Special Projects. The unit's role is discussed and funding decisions that led to its demise are explained. (LRW)

  6. Comparison of Depth of Cure, Hardness and Heat Generation of LED and High Intensity QTH Light Sources.

    PubMed

    Mousavinasab, Sayed Mostafa; Meyers, Ian

    2011-07-01

    To compare curing performance of a second generation LED curing light with a high power tungsten quartz halogen (QTH). A hybrid composite resin (Filtek Z 250, 3M, USA) was used as test material and cured using a second generation LED light (Translux Power Blue™, Heraus Kulzer ,Germany) or a very high power QTH light unit (EMS, Switzerland). A two split aluminum mold was used to prepare ten samples with LED light source cured for forty seconds and ten samples prepared using high power QTH light unit, cured for four or six seconds recommended exposure time. Hardness, depth of cure (DOC) and thermal rise during exposure time by these light sources were measured. The data submitted to analysis of variance (ANOVA), Tukey's and student's t tests at 5% significance level. Significant differences were found in hardness, DOC of samples cured by above mentioned light sources and also in thermal rises during exposure time. The curing performance of the tested QTH was not as well as the LED light. TPB light source produced the maximum hardness (81.25, 73.29, 65.49,55.83 and 24.53 for 0 mm, 1 mm, 2 mm, 3 mm and 4 mm intervals) and DOC (2.64 mm) values with forty seconds irradiation time and the high power (QTH) the least hardness (73.27, 61.51 and 31.59 for 0 mm, 1 mm and 2 mm, respectively) and DOC (2 mm) values with four seconds irradiation time. Thermal rises during 4 s and 6 s curing time using high power QTH and tested LED were 1.88°C, 3°C and 1.87°C, respectively. The used high power LED light produced greater hardness and depth of cure during forty seconds exposure time compared to high power QTH light with four or six seconds curing time. Thermal rise during 6 s curing time with QTH was greater compared to thermal changes occurred during 40 s curing time with tested LED light source. There was no difference seen in thermal changes caused by LED light with 40 s and QTH light with 4 s exposure time.

  7. The effective way

    NASA Astrophysics Data System (ADS)

    Fruchart, Michel; Vitelli, Vincenzo

    2018-03-01

    A theoretical framework for the design of so-called perturbative metamaterials, based on weakly interacting unit cells, has led to the experimental demonstration of a quadrupole topological insulator.

  8. Recent results of the Defect-Induced Mix Experiments (DIME) on NIF

    NASA Astrophysics Data System (ADS)

    Schmitt, M. J.; Bradley, P. A.; Cobble, J. A.; Hakel, P.; Hsu, S. C.; Krasheninnikova, N. S.; Kyrala, G. A.; Murphy, T. J.; Obrey, K. A.; Shah, R. C.; Tregillis, I. L.; Craxton, S. C.; McKenty, P. W.; Mancini, R. C.; Johns, H. M.; Joshi, Tirtha; Mayes, Daniel

    2012-10-01

    Investigations of directly driven implosions have been performed including experiments on Omega, and more recently NIF, to deduce the extent and uniformity of 4π and defect-induced mix near the shell/gas interface of plastic (CH) capsules filled with 5 atm D2 gas. Imaging diagnostics are used to measure the spatial variation of mix caused by the growth of non-uniformities in both capsule and laser drive characteristics. Thin (2μm) layers containing 1-2% (atomic) mid-Z dopants are imaged spectrally at late time in the implosion using multiple monochromatic imaging of H-like and He-like atomic line emission. Areal image backlighting of the capsules provides both r(t) and the symmetry of the implosion. Recent results will be shown including inferred 4π mix width, laser imprint induced mix, and mix from capsule variations.

  9. X-Pinch And Its Applications In X-ray Radiograph

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou Xiaobing; Wang Xinxin; Liu Rui

    2009-07-07

    An X-pinch device and the related diagnostics of x-ray emission from X-pinch were briefly described. The time-resolved x-ray measurements with photoconducting diodes show that the x-ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x-ray pulse, two point x-ray sources of size ranging from 100 mum to 5 mum and depending on cut-off x-ray photon energy were usually observed on the pinhole pictures. The x-pinch was used as x-ray source for backlighting of the electrical explosion of single wire and the evolution of X-pinch, andmore » for phase-contrast imaging of soft biological objects such as a small shrimp and a mosquito.« less

  10. Pattern optimization of compound optical film for uniformity improvement in liquid-crystal displays

    NASA Astrophysics Data System (ADS)

    Huang, Bing-Le; Lin, Jin-tang; Ye, Yun; Xu, Sheng; Chen, En-guo; Guo, Tai-Liang

    2017-12-01

    The density dynamic adjustment algorithm (DDAA) is designed to efficiently promote the uniformity of the integrated backlight module (IBLM) by adjusting the microstructures' distribution on the compound optical film (COF), in which the COF is constructed in the SolidWorks and simulated in the TracePro. In order to demonstrate the universality of the proposed algorithm, the initial distribution is allocated by the Bezier curve instead of an empirical value. Simulation results maintains that the uniformity of the IBLM reaches over 90% only after four rounds. Moreover, the vertical and horizontal full width at half maximum of angular intensity are collimated to 24 deg and 14 deg, respectively. Compared with the current industry requirement, the IBLM has an 85% higher luminance uniformity of the emerging light, which demonstrate the feasibility and universality of the proposed algorithm.

  11. KSC-08pd2342

    NASA Image and Video Library

    2008-08-08

    CAPE CANAVERAL, Fla. – Technicians in the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center perform backlight inspection and cleaning on the Fine Guidance Sensor, or FGS. The FGS is part of the payload for the fifth and final Hubble servicing mission, STS-125, aboard space shuttle Atlantis. Black light inspection uses UVA fluorescence to detect possible particulate microcontamination, minute cracks or fluid leaks. An FGS consists of a large structure housing a collection of mirrors, lenses, servos, prisms, beam splitters and photomultiplier tubes. There are three fine guidance sensors on Hubble located at 90-degree intervals around the circumference of the telescope. Along with the gyroscopes, the optical sensors are a key component of Hubble’s highly complex but extraordinarily effective “pointing control system.” Atlantis is targeted to launch Oct. 8. Photo credit: NASA/Jack Pfaller

  12. KSC-08pd2341

    NASA Image and Video Library

    2008-08-08

    CAPE CANAVERAL, Fla. – Technicians in the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center perform backlight inspection and cleaning on the Fine Guidance Sensor, or FGS. The FGS is part of the payload for the fifth and final Hubble servicing mission, STS-125, aboard space shuttle Atlantis. Black light inspection uses UVA fluorescence to detect possible particulate microcontamination, minute cracks or fluid leaks. An FGS consists of a large structure housing a collection of mirrors, lenses, servos, prisms, beam splitters and photomultiplier tubes. There are three fine guidance sensors on Hubble located at 90-degree intervals around the circumference of the telescope. Along with the gyroscopes, the optical sensors are a key component of Hubble’s highly complex but extraordinarily effective “pointing control system.” Atlantis is targeted to launch Oct. 8. Photo credit: NASA/Jack Pfaller

  13. Flash Kα radiography of laser-driven solid sphere compression for fast ignition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawada, H.; Lee, S.; Shiroto, T.

    2016-06-20

    Time-resolved compression of a laser-driven solid deuterated plastic sphere with a cone was measured with flash Kα x-ray radiography. A spherically converging shockwave launched by nanosecond GEKKO XII beams was used for compression while a flash of 4.51 keV Ti Kα x-ray backlighter was produced by a high-intensity, picosecond laser LFEX (Laser for Fast ignition EXperiment) near peak compression for radiography. Areal densities of the compressed core were inferred from two-dimensional backlit x-ray images recorded with a narrow-band spherical crystal imager. The maximum areal density in the experiment was estimated to be 87 ± 26 mg/cm 2. Lastly, the temporalmore » evolution of the experimental and simulated areal densities with a 2-D radiation-hydrodynamics code is in good agreement.« less

  14. Note: A monoenergetic proton backlighter for the National Ignition Facility

    DOE PAGES

    Rygg, J. R.; Zylstra, A. B.; Seguin, F. H.; ...

    2015-11-12

    Here, a monoenergetic, isotropic proton source suitable for proton radiography applications has been demonstrated at the National Ignition Facility (NIF). A deuterium and helium-3 gas-filled glass capsule was imploded with 39 kJ of laser energy from 24 of NIF’s 192 beams. Spectral, spatial, and temporal measurements of the 15-MeV proton product of the 3He(d,p) 4He nuclear reaction reveal a bright (10 10 protons/sphere), monoenergetic (ΔE/E = 4%) spectrum with a compact size (80 µm) and isotropic emission (~13% proton fluence variation and <0.4% mean energy variation). Simultaneous measurements of products produced by the D(d,p)T and D(d,n) 3He reactions also showmore » 2 × 10 10 isotropically distributed 3-MeV protons.« less

  15. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, G. N.; Izumi, N.; Landen, O. L.

    2016-08-03

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments, and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro channel plate) to provide gating and high DQE at the 40–200keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Here, experiments were performed atmore » energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.« less

  16. Flash Kα radiography of laser-driven solid sphere compression for fast ignition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawada, H.; Lee, S.; Nagatomo, H.

    2016-06-20

    Time-resolved compression of a laser-driven solid deuterated plastic sphere with a cone was measured with flash Kα x-ray radiography. A spherically converging shockwave launched by nanosecond GEKKO XII beams was used for compression while a flash of 4.51 keV Ti Kα x-ray backlighter was produced by a high-intensity, picosecond laser LFEX (Laser for Fast ignition EXperiment) near peak compression for radiography. Areal densities of the compressed core were inferred from two-dimensional backlit x-ray images recorded with a narrow-band spherical crystal imager. The maximum areal density in the experiment was estimated to be 87 ± 26 mg/cm{sup 2}. The temporal evolution of the experimental andmore » simulated areal densities with a 2-D radiation-hydrodynamics code is in good agreement.« less

  17. Indigenous Youth Peer-Led Health Promotion in Canada, New Zealand, Australia, and the United States: A Systematic Review of the Approaches, Study Designs, and Effectiveness.

    PubMed

    Vujcich, Daniel; Thomas, Jessica; Crawford, Katy; Ward, James

    2018-01-01

    Youth peer-led interventions have become a popular way of sharing health information with young people and appear well suited to Indigenous community contexts. However, no systematic reviews focusing on Indigenous youth have been published. We conducted a systematic review to understand the range and characteristics of Indigenous youth-led health promotion projects implemented and their effectiveness. A systematic search of Medline, Embase, and ProQuest Social Sciences databases was conducted, supplemented by gray literature searches. Included studies focused on interventions where young Indigenous people delivered health information to age-matched peers. Twenty-four studies were identified for inclusion, based on 20 interventions (9 Australian, 4 Canadian, and 7 from the United States of America). Only one intervention was evaluated using a randomized controlled study design. The majority of evaluations took the form of pre-post studies. Methodological limitations were identified in a majority of studies. Study outcomes included improved knowledge, attitude, and behaviors. Currently, there is limited high quality evidence for the effectiveness of peer-led health interventions with Indigenous young people, and the literature is dominated by Australian-based sexual health interventions. More systematic research investigating the effectiveness of peer-led inventions is required, specifically with Indigenous populations. To improve health outcomes for Indigenous youth, greater knowledge of the mechanisms and context under which peer-delivered health promotion is effective in comparison to other methods of health promotion is needed.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paget, Maria L.; McCullough, Jeffrey J.; Steward, Heidi E.

    Solid-state lighting products for general lighting applications are now gaining a market presence, and more and more people are asking, “Which of these are ‘good’ products? Do they perform as claimed? How do they compare? Light Emitting Diodes (LEDs) differ from other light sources enough to require new procedures for measuring their performance and comparing to other lighting options, so both manufacturers and buyers are facing a learning curve. The energy-efficiency community has traditionally compared light sources based on system efficacy: rated lamp lumens divided by power into the system. This doesn’t work for LEDs because there are no standardmore » LED “lamp” packages and no lamp ratings, and because LED performance depends heavily on thermal, electrical, and optical design of complete lighting unit or ‘luminaire’. Luminaire efficacy is the preferred metric for LEDs because it measures the net light output from the luminaire divided by power into the system.« less

  19. The Sociology of the Deceased Harvard Medical Unit at Boston City Hospital.

    PubMed

    Tishler, Peter V

    2015-12-01

    Many graduates of the Harvard Medical Unit (HMU) at Boston City Hospital, in either the clinical training/residency program or the research program at the Thorndike Memorial Laboratory, contributed in major ways to the HMU and constantly relived their HMU experiences. The HMU staff physicians, descending from founder and mentor physicians Francis W. Peabody, Soma Weiss, and George R. Minot, were dedicated to the teaching, development, and leadership of its clinical and research trainees, whose confidence and dedication to patient care as a result of their mentorship led many to lifelong achievements as clinicians, teachers, and mentors. Their experience also led to a lifelong love of the HMU (despite its loss), camaraderie, happiness, and intense friendships with their associates.

  20. The Sociology of the Deceased Harvard Medical Unit at Boston City Hospital

    PubMed Central

    Tishler, Peter V.

    2015-01-01

    Many graduates of the Harvard Medical Unit (HMU) at Boston City Hospital, in either the clinical training/residency program or the research program at the Thorndike Memorial Laboratory, contributed in major ways to the HMU and constantly relived their HMU experiences. The HMU staff physicians, descending from founder and mentor physicians Francis W. Peabody, Soma Weiss, and George R. Minot, were dedicated to the teaching, development, and leadership of its clinical and research trainees, whose confidence and dedication to patient care as a result of their mentorship led many to lifelong achievements as clinicians, teachers, and mentors. Their experience also led to a lifelong love of the HMU (despite its loss), camaraderie, happiness, and intense friendships with their associates. PMID:26604868

  1. Cooperative Security in the Pacific Basin. The 1988 Pacific Symposium,

    DTIC Science & Technology

    1990-01-01

    show the same pattern which Taiwan established and Singapore is following closely. Among the four Asian NICs Hong Kong led the pattern early, followed...government, have become a driving force for the tri- angular trade pattern among the United States, Japan, and the East Asian countries. JAPANESE DIRECT...Division of roles between the United States and Japan in East Asia has unintentionally effected a triangular trade pattern among the United States, Japan

  2. Energy-Saving Tunnel Illumination System Based on LED's Intelligent Control

    NASA Astrophysics Data System (ADS)

    Guo, Shanshan; Gu, Hanting; Wu, Lan; Jiang, Shuixiu

    2011-02-01

    At present there is a lot of electric energy wastage in tunnel illumination, whose design is based on the maximum brightness outside and the maximum vehicle speed all year round. LED's energy consumption is low, and the control of its brightness is simple and effective. It can be quickly adjusted between 0-100% of its maximum brightness, and will not affect the service life. Therefore, using LED as tunnel's illumination source, we can achieve a good energy saving effect. According to real-time data acquisition of vehicle speed, traffic flow and brightness outside the tunnel, the auto real-time control of tunnel illumination can be achieved. And the system regulated the LED luminance by means of combination of LED power module and intelligent control module. The tunnel information was detected by inspection equipments, which included luminometer, vehicle detector, and received by RTU(Remote Terminal Unit), then synchronously transmitted to PC. After data processing, RTU emitted the dimming signal to the LED driver to adjust the brightness of LED. Despite the relatively high cost of high-power LED lights, the enormous energy-saving effect and the well-behaved controllability is beyond compare to other lighting devices.

  3. Evaluating UV-C LED disinfection performance and investigating potential dual-wavelength synergy.

    PubMed

    Beck, Sara E; Ryu, Hodon; Boczek, Laura A; Cashdollar, Jennifer L; Jeanis, Kaitlyn M; Rosenblum, James S; Lawal, Oliver R; Linden, Karl G

    2017-02-01

    A dual-wavelength UV-C LED unit, emitting at peaks of 260 nm, 280 nm, and the combination of 260|280 nm together was evaluated for its inactivation efficacy and energy efficiency at disinfecting Escherichia coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores, compared to conventional low-pressure and medium-pressure UV mercury vapor lamps. The dual-wavelength unit was also used to measure potential synergistic effects of multiple wavelengths on bacterial and viral inactivation and DNA and RNA damage. All five UV sources demonstrated similar inactivation of E. coli. For MS2, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was most effective. When measuring electrical energy per order of reduction, the LP UV lamp was most efficient for inactivating E. coli and MS2; the LP UV and MP UV mercury lamps were equally efficient for HAdV2 and B. pumilus spores. Among the UV-C LEDs, there was no statistical difference in electrical efficiency for inactivating MS2, HAdV2, and B. pumilus spores. The 260 nm and 260|280 nm LEDs had a statistical energy advantage for E. coli inactivation. For UV-C LEDs to match the electrical efficiency per order of log reduction of conventional LP UV sources, they must reach efficiencies of 25-39% or be improved on by smart reactor design. No dual wavelength synergies were detected for bacterial and viral inactivation nor for DNA and RNA damage. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. LED and Halogen Light Transmission through a CAD/CAM Lithium Disilicate Glass-Ceramic.

    PubMed

    Pereira, Carolina Nemesio de Barros; De Magalhães, Cláudia Silami; Daleprane, Bruno; Peixoto, Rogéli Tibúrcio Ribeiro da Cunha; Ferreira, Raquel da Conceição; Cury, Luiz Alberto; Moreira, Allyson Nogueira

    2015-01-01

    The effect of thickness, shade and translucency of CAD/CAM lithium disilicate glass-ceramic on light transmission of light-emitting diode (LED) and quartz-tungsten-halogen units (QTH) were evaluated. Ceramic IPS e.max CAD shades A1, A2, A3, A3.5, high (HT) and low (LT) translucency were cut (1, 2, 3, 4 and 5 mm). Light sources emission spectra were determined. Light intensity incident and transmitted through each ceramic sample was measured to determine light transmission percentage (TP). Statistical analysis used a linear regression model. There was significant interaction between light source and ceramic translucency (p=0.008) and strong negative correlation (R=-0.845, p<0.001) between ceramic thickness and TP. Increasing one unit in thickness led to 3.17 reduction in TP. There was no significant difference in TP (p=0.124) between shades A1 (ß1=0) and A2 (ß1=-0.45) but significant reduction occurred for A3 (ß1=-0.83) and A3.5 (ß1=-2.18). The interaction QTH/HT provided higher TP (ß1=0) than LED/HT (ß1=-2.92), QTH/LT (ß1=-3.75) and LED/LT (ß1=-5.58). Light transmission was more effective using halogen source and high-translucency ceramics, decreased as the ceramic thickness increased and was higher for the lighter shades, A1 and A2. From the regression model (R2=0.85), an equation was obtained to estimate TP value using each variable ß1 found. A maximum TP of 25% for QTH and 20% for LED was found, suggesting that ceramic light attenuation could compromise light cured and dual cure resin cements polymerization.

  5. Fundamental Characteristics of Deep-UV Light-Emitting Diodes and Their Application To Control Foodborne Pathogens.

    PubMed

    Shin, Joo-Yeon; Kim, Soo-Ji; Kim, Do-Kyun; Kang, Dong-Hyun

    2016-01-01

    Low-pressure mercury UV (LP-UV) lamps have long been used for bacterial inactivation, but due to certain disadvantages, such as the possibility of mercury leakage, deep-UV-C light-emitting diodes (DUV-LEDs) for disinfection have recently been of great interest as an alternative. Therefore, in this study, we examined the basic spectral properties of DUV-LEDs and the effects of UV-C irradiation for inactivating foodborne pathogens, including Escherichia coli O157:H7, Salmonella enterica serovar Typhimurium, and Listeria monocytogenes, on solid media, as well as in water. As the temperature increased, DUV-LED light intensity decreased slightly, whereas LP-UV lamps showed increasing intensity until they reached a peak at around 30°C. As the irradiation dosage and temperature increased, E. coli O157:H7 and S. Typhimurium experienced 5- to 6-log-unit reductions. L. monocytogenes was reduced by over 5 log units at a dose of 1.67 mJ/cm(2). At 90% relative humidity (RH), only E. coli O157:H7 experienced inactivation significantly greater than at 30 and 60% RH. In a water treatment study involving a continuous system, 6.38-, 5.81-, and 3.47-log-unit reductions were achieved in E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively, at 0.5 liter per minute (LPM) and 200 mW output power. The results of this study suggest that the use of DUV-LEDs may compensate for the drawbacks of using LP-UV lamps to inactivate foodborne pathogens. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Solid-state semiconductors are better alternatives to arc-lamps for efficient and uniform illumination in minimal access surgery.

    PubMed

    Lee, Alex C H; Elson, Daniel S; Neil, Mark A; Kumar, Sunil; Ling, Bingo W; Bello, Fernando; Hanna, George B

    2009-03-01

    Current arc-lamp illumination systems have a number of technical and ergonomic limitations. White light-emitting diodes (LEDs) are energy-efficient solid-state lighting devices which are small, durable and inexpensive. Their use as an alternative to arc-lamp light sources in minimal access surgery has not been explored. This study aims to develop an LED-based endo-illuminator and to determine its lighting characteristics for use in minimal access surgery. We developed an LED endo-illuminator using a white LED mounted at the tip of a steel rod. Offline image analysis was carried out to compare the illuminated field using the LED endo-illuminator or an arc-lamp based endoscope in terms of uniformity, shadow sharpness and overall image intensity. Direct radiometric power measurements in light intensity and stability were obtained. Visual perception of fine details at the peripheral endoscopic field was assessed by 13 subjects using the different illumination systems. Illumination from the LED endo-illuminator was more uniform compared to illumination from an arc-lamp source, especially at the closer distance of 4 cm (0.0006 versus 0.0028 arbitrary units--lower value indicates more uniform illumination). The shadows were also sharper (edge widths of 16 versus 44 pixels for the first edge and 15 versus 61 pixels for the second edge). The overall mean image intensity was higher (127 versus 100 arbitrary units) when using the autoshutter mode despite the lower direct radiometric power, about one tenth of the arc-lamp endoscopic system. The illumination was also more stable with less flickering (0.02% versus 5% of total power in non-DC components). Higher median scores on visual perception was also obtained (237 versus 157, p < 0.001). The LED endo-illuminator provides more uniform illumination with sharper shadows, less flickering and better illumination for visual perception than the arc-lamp-based system currently used.

  7. Interaction of LED light with coinitiator-containing composite resins: effect of dual peaks.

    PubMed

    Sim, Jae-Seong; Seol, Hyo-Joung; Park, Jeong-Kil; Garcia-Godoy, Franklin; Kim, Hyung-Il; Kwon, Yong Hoon

    2012-10-01

    Recently the colour stability of composite resins has been an issue due to the emphasis on the aesthetics of restored teeth. The purpose of the present study was to investigate how dual-peak LED units affect the polymerization of coinitiator-containing composite resins. Five composite resins [coinitiator-containing: Aelite LS Posterior (AL), Tetric EvoCeram (TE), and Vit-l-escence (VI); only CQ-containing: Grandio (GD) and Filtek Z350 (Z3)] were light cured using four different light-curing units (LCUs). Among them, Bluephase G2 (BP) and G-light (GL) were dual-peak LED LCUs. Microhardness, polymerization shrinkage, flexural, and compressive properties were measured. BP and GL had no consistent effect on the microhardness of AL, TE, and VI on the top and bottom surfaces of resin specimens. Among the specimens, AL and VI showed the least (9.86-10.41 μm) and greatest (17.58-19.21 μm) polymerization shrinkage, respectively. However, the effect of BP and GL on the shrinkage of specimens was not consistent. Among the specimens, GD showed the greatest flexural properties [strength (FS) and modulus (FM)] and TE showed the lowest flexural and compressive properties [strength (CS) and modulus (CM)]. In same resin product, maximum FS and CS differences due to the different LCUs were 10.3-21.0% and 3.6-9.2%, respectively. Furthermore, the influences of BP and GL on FS and CS were not consistent. The tested dual-peak LED LCUs had no consistent synergic effect on the polymerization of coinitiator-containing composite resins as compared with QTH and single-peak LED LCUs. The dual-peak LED LCUs achieve a similar degree of polymerization in coinitiator-composite resins as QTH and single-peak LED LCUs did. Choice of LCU does not appear to be a determinant of the light curing of coinitiator-composite resins. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Preventing China s Rise: Maintaining United States Hegemony in the Face of a Rising China

    DTIC Science & Technology

    2014-12-04

    Indies for supplies, the American Committee of Secret Correspondence, initially led by Silas Deane, and later joined by Benjamin Franklin , petitioned the...A Way Ahead ................................................................................................................................. 46...applied in the current environment. The fourth section, titled “A Way Ahead,” discusses a potential course of action the United States could follow in

  9. Importance of Carolina Bays to the Avifauna of Pinelands in the Southeastern United States

    Treesearch

    Stephen Czapka; John Kilgo

    2011-01-01

    Past anthropogenic activity has led to the destruction or alteration of Carolina bay wetlands throughout the southeastern United States. Presently, urban development, combined with a 2001 ruling by the US Supreme Court relaxing protection of isolated wetlands, poses an increasing threat to these and other isolated wetland systems; however, little information exists on...

  10. The Election of 1800: Alexander Hamilton and the Death of the Federalist Party.

    ERIC Educational Resources Information Center

    Holbrook-DeFeo, Gary

    1993-01-01

    Describes the significance of the election of 1800 in the development of political parties in the United States. Contends that Alexander Hamilton's view of the United States Constitution was dangerous for the new nation and led to a permanent split in the Federalist Party. Includes a resource bibliography for teachers wishing to incorporate this…

  11. Small Combat Arms Unit Leader Training Techniques: Rules of Play for Two Player/Multiplayer Infantry Mapboard Games.

    DTIC Science & Technology

    1979-01-01

    exercises for leadership training. Initial efforts led to the development of a mapboard game. The ’board game’ initially developed was a two-sided, free ... play map exercise for teaching infantry tactics to small unit leaders at the platoon level organizations. It was found, however, that for the benefits

  12. Distance Learning for Food Security and Rural Development: A Perspective from the United Nations Food and Agriculture Organization.

    ERIC Educational Resources Information Center

    McLean, Scott; Gasperini, Lavinia; Rudgard, Stephen

    2002-01-01

    The distance learning experiences of the United Nations Food and Agriculture Organization led to the following suggestions for applying distance learning strategies to the challenges of food security and rural development: use distance learning for the right reasons, be sensitive to context, use existing infrastructure, engage stakeholders, and…

  13. Real-World Units in the Conceptual Age

    ERIC Educational Resources Information Center

    Campillo, Blanca; Pierson, Bo Hyun

    2014-01-01

    During an eight-week series of investigations, a class of third-grade students learned how interactions between forces are used to advance technology in their world. This five-part forces and interaction unit was led by a guiding question: How does engineering and design work in the world, and how does it affect our lives? As they explored this…

  14. Resources for Social Change. Race in the United States.

    ERIC Educational Resources Information Center

    Coleman, James S.

    This book draws together some of the emerging theories of directed social change for application to a particular problem: the social, economic, and political positions of Negroes in the United States. An orientation towards social problems, which sees change as a consequence of man's action and thus potentially under his control, has led to the…

  15. The National Wind Erosion Research Network: Building a standardized long-term data resource for aeolian research, modeling and land management

    USDA-ARS?s Scientific Manuscript database

    The National Wind Erosion Research Network was established in 2014 as a collaborative effort led by the United States Department of Agriculture’s Agricultural Research Service and Natural Resources Conservation Service, and the United States Department of the Interior Bureau of Land Management, to a...

  16. Women׳s birthplace decision-making, the role of confidence: Part of the Evaluating Maternity Units study, New Zealand.

    PubMed

    Grigg, Celia P; Tracy, Sally K; Schmied, Virginia; Daellenbach, Rea; Kensington, Mary

    2015-06-01

    to explore women׳s birthplace decision-making and identify the factors which enable women to plan to give birth in a freestanding midwifery-led primary level maternity unit rather than in an obstetric-led tertiary level maternity hospital in New Zealand. a mixed methods prospective cohort design. data from eight focus groups (37 women) and a six week postpartum survey (571 women, 82%) were analysed using thematic analysis and descriptive statistics. The qualitative data from the focus groups and survey were the primary data sources and were integrated at the analysis stage; and the secondary qualitative and quantitative data were integrated at the interpretation stage. Christchurch, New Zealand, with one tertiary maternity hospital and four primary level maternity units (2010-2012). well (at 'low risk' of developing complications), pregnant women booked to give birth in one of the primary units or the tertiary hospital. All women received midwifery continuity of care, regardless of their intended or actual birthplace. five core themes were identified: the birth process, women׳s self-belief in their ability to give birth, midwives, the health system and birth place. 'Confidence' was identified as the overarching concept influencing the themes. Women who chose to give birth in a primary maternity unit appeared to differ markedly in their beliefs regarding their optimal birthplace compared to women who chose to give birth in a tertiary maternity hospital. The women who planned a primary maternity unit birth expressed confidence in the birth process, their ability to give birth, their midwife, the maternity system and/or the primary unit itself. The women planning to give birth in a tertiary hospital did not express confidence in the birth process, their ability to give birth, the system for transfers and/or the primary unit as a birthplace, although they did express confidence in their midwife. birthplace is a profoundly important aspect of women׳s experience of childbirth. Birthplace decision-making is complex, in common with many other aspects of childbirth. A multiplicity of factors needs converge in order for all those involved to gain the confidence required to plan what, in this context, might be considered a 'countercultural' decision to give birth at a midwife-led primary maternity unit. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Real-time Kinematics Base Station and Survey Unit Setup Method for the Synchronous Impulse Reconstruction (SIRE) Radar

    DTIC Science & Technology

    2012-12-01

    GPS receiver, the Ashtech ProMark 500; a 3.4-GHz radio modem, the FreeWave 3400-SMR; a display unit, the Magellan MobileMapper CX; a 12-V battery pack...Figure 8. Bottom view of the ProMark 500. 3.1 Survey Unit RTK GPS Setup The following are the procedures for setting up...the RTK GPS Survey Unit: 1. Connect the radio modem to the ProMark 500 with serial cable #7 and #8. Display Screen Scroll Button Power LED Log

  18. Pseudomonas aeruginosa outbreak in a pediatric oncology care unit caused by an errant water jet into contaminated siphons.

    PubMed

    Schneider, Henriette; Geginat, Gernot; Hogardt, Michael; Kramer, Alexandra; Dürken, Matthias; Schroten, Horst; Tenenbaum, Tobias

    2012-06-01

    We analyzed an outbreak of invasive infections with an exotoxin U positive Pseudomonas aeruginosa strain within a pediatric oncology care unit. Environmental sampling and molecular characterization of the Pseudomonas aeruginosa strains led to identification of the outbreak source. An errant water jet into the sink within patient rooms was observed. Optimized outbreak management resulted in an abundance of further Pseudomonas aeruginosa infections within the pediatric oncology care unit.

  19. Demonstration of a large-size horizontal light-field display based on the LED panel and the micro-pinhole unit array

    NASA Astrophysics Data System (ADS)

    Yang, Le; Sang, Xinzhu; Yu, Xunbo; Liu, Boyang; Liu, Li; Yang, Shenwu; Yan, Binbin; Du, Jingyan; Gao, Chao

    2018-05-01

    A 54-inch horizontal-parallax only light-field display based on the light-emitting diode (LED) panel and the micro-pinhole unit array (MPUA) is demonstrated. Normally, the perceived 3D effect of the three-dimensional (3D) display with smooth motion parallax and abundant light-field information can be enhanced with increasing the density of viewpoints. However, the density of viewpoints is inversely proportional to the spatial display resolution for the conventional integral imaging. Here, a special MPUA is designed and fabricated, and the displayed 3D scene constructed by the proposed horizontal light-field display is presented. Compared with the conventional integral imaging, both the density of horizontal viewpoints and the spatial display resolution are significantly improved. In the experiment, A 54-inch horizontal light-field display with 42.8° viewing angle based on the LED panel with the resolution of 1280 × 720 and the MPUA is realized, which can provide natural 3D visual effect to observers with high quality.

  20. Provision and practice of specialist preterm labour clinics: a UK survey of practice.

    PubMed

    Sharp, A N; Alfirevic, Z

    2014-03-01

    To identify the current status of specialist preterm labour (PTL) clinic provision and management within the UK. Postal survey of clinical practice. All consultant-led obstetric units within the UK. A questionnaire was sent by post to all 210 NHS consultant-led obstetric units within the UK. Units that had a specialist PTL clinic were asked to complete a further 20 questions defining their protocol for risk stratification and management. Current practice in specialist preterm labour clinics. We have identified 23 specialist clinics; the most common indications for attendance were previous PTL (100%), preterm prelabour rupture of membranes (95%), two large loop excisions of the transformation zone (95%) or cone biopsy (95%). There was significant heterogeneity in the indications for and method of primary treatment for short cervix, with cervical cerclage used in 45% of units, progesterone in 18% of units and Arabin cervical pessary in 5%. A further 23% used multiple treatment modalities in combination. A significant heterogeneity in all topics surveyed suggests an urgent need for networking, more evidence-based guidelines and prospective comparative audits to ascertain the real impact of specialist PTL clinics on the reduction in preterm birth and its sequelae. © 2013 Royal College of Obstetricians and Gynaecologists.

  1. The acute physicians unit in scarborough hospital.

    PubMed

    Khadjooi, Kayvan; Dimopoulos, Christos; Paterson, John

    2009-01-01

    The aim of Acute Physicians Unit (APU) in Scarborough Hospital is consultant led delivery of acute medical care. It operates weekdays from 9am to 5pm, staffed by a consultant physician, a trained nurse and an auxiliary nurse. We reviewed the APU activity over 38 months. 7170 patients were referred to APU, mainly from GPs (59.6%) and A&E (26.5%). The most common type of referrals: cardiovascular 21%, neurological 16.9% and respiratory 15.1%. It prevented admission in 2217 cases (30.9%): 22.4% were sent home after assessment in APU and in 8.5% telephone advice was sufficient. The APU has led to early consultant review in 53% of admissions, discharge of 31% of patients and is a useful source of consultation for GPs.

  2. The history of the coronary care unit.

    PubMed

    Khush, Kiran K; Rapaport, Elliot; Waters, David

    2005-10-01

    The first coronary care units were established in the early 1960s in an attempt to reduce mortality from acute myocardial infarction. Pioneering cardiologists recognized the threat of death due to malignant arrhythmias in the postinfarction setting, and developed techniques for successful external defibrillation. The ability to abort sudden death led to continuous monitoring of the cardiac rhythm and an organized system of cardiopulmonary resuscitation, incorporating external defibrillation with cardiac drugs and specialized equipment. Arrhythmia monitoring and cardiopulmonary resuscitation could be performed by trained nursing staff, which eliminated delays in treatment and significantly reduced mortality. These early triumphs in aborting sudden death led to the development of techniques to treat cardiogenic shock, limit infarct size and initiate prehospital coronary care, all of which laid the foundation for the current era of interventional cardiology.

  3. Synthesis of national reports for Rio+20

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2013-01-15

    In the lead up to the United Nations Conference on Sustainable Development (Rio+20), which took place in Brazil in June 2012, there were numerous efforts in countries around the world to help governments, civil society organizations and individuals prepare for the event. One of the more significant efforts led by UNDP in collaboration with the United Nations Department of Economic and Social Affairs (UN DESA) was a support programme to 72 countries across all regions to build a consensus on national views around the themes and objectives of the Rio+20 Conference. This report highlights significant advances in sustainable development frommore » almost 60 country reports and underscores the challenges and bottlenecks to moving beyond the economic-led growth strategies of the past 20 years.« less

  4. Effect of Light-Cured Resin Cement Application on Translucency of Ceramic Veneers and Light Transmission of LED Polymerization Units.

    PubMed

    Zhang, Lei; Luo, Xiao Ping; Tan, Ren Xiang

    2018-05-31

    To evaluate the effect of light-cured resin cement application based on etching and silanization on the translucent property of ceramic veneers in different thicknesses, testing the hypothesis that the surface treatment and subsequent resin cement application could influence the translucency of ceramic veneers. The relationship between translucency of ceramic veneers and light transmission irradiated by LED polymerization units was also determined. 40 specimens (10 mm diameter) were fabricated from IPS e.max Press HT A2 ceramic ingots, and polished to 0.3 ± 0.01 mm, 0.5 ± 0.01 mm, 0.7 ± 0.01 mm, 1.0 ± 0.01 mm, and 1.5 ± 0.01 mm thick (n = 8/group). One surface of each disc was etched with HF acid, silanized with Monobond-S, and applied with a light-cured resin cement (Variolink N Transparent Base). Before and after the above procedure, the total luminous transmittance (τ) of all specimens was assessed by a spectrophotometer in a wavelength range of 380-780 nm. A handheld radiometer was used to measure the light intensity irradiated by three LED polymerization units. Light transmission (LT) through ceramic specimens after resin cement application was calculated. Data were statistically analyzed using two-way ANOVA (p = 0.05) and Tukey's test. The correlation between translucency (τ) of ceramic veneers after resin cement application and light transmission (LT) of curing units was statistically evaluated using Spearman correlation test (p = 0.05). With the increase of ceramic thickness, the transmittance decreased significantly (p < 0.05). For the 0.3-mm, 0.5-mm, and 0.7-mm-thick groups, the transmittance of ceramic specimens was statistically significantly lower after resin cement application (p < 0.05). The r value of Bluephase C8 was 0.988, 0.977 for Bluphase, and 0.883 for Bluephase 20i, indicating that the light transmission (LT%) was positively correlated to the translucency of ceramic veneers, regardless of the type of curing units. After the light-cured resin cement application based on etching and silanization, the ceramic veneers (less than 0.7-mm thick) were less translucent, and the translucency decreased when the thickness increased. Because of the lower translucency of ceramic veneers, the light intensity of LED units transmitted to resin layer would decrease when curing. © 2018 by the American College of Prosthodontists.

  5. Photodynamic Therapy for Actinic Keratoses: A Randomized Prospective Non-sponsored Cost-effectiveness Study of Daylight-mediated Treatment Compared with Light-emitting Diode Treatment.

    PubMed

    Neittaanmäki-Perttu, Noora; Grönroos, Mari; Karppinen, Toni; Snellman, Erna; Rissanen, Pekka

    2016-02-01

    Daylight-mediated photodynamic therapy (DL-PDT) is considered as effective as conventional PDT using artificial light (light-emitting diode (LED)-PDT) for treatment of actinic keratoses (AK). This randomized prospective non-sponsored study assessed the cost-effectiveness of DL-PDT compared with LED-PDT. Seventy patients with 210 AKs were randomized to DL-PDT or LED-PDT groups. Effectiveness was assessed at 6 months. The costs included societal costs and private costs, including the time patients spent in treatment. Results are presented as incremental cost-effectiveness ratio (ICER). The total costs per patient were significantly lower for DL-PDT (€132) compared with LED-PDT (€170), giving a cost saving of €38 (p = 0.022). The estimated probabilities for patients' complete response were 0.429 for DL-PDT and 0.686 for LED-PDT; a difference in probability of being healed of 0.257. ICER showed a monetary gain of €147 per unit of effectiveness lost. DL-PDT is less costly and less effective than LED-PDT. In terms of cost-effectiveness analysis, DL-PDT provides lower value for money compared with LED-PDT.

  6. A Peer-Assisted Teaching Scheme to Improve Units with Critically Low Student Satisfaction: Opportunities and Challenges

    ERIC Educational Resources Information Center

    Carbone, Angela

    2014-01-01

    This paper outlines a peer-assisted teaching scheme (PATS) which was piloted in the Faculty of Information Technology at Monash University, Australia to address the low student satisfaction with the quality of information and communication technology units. Positive results from the pilot scheme led to a trial of the scheme in other disciplines.…

  7. The Fate of Ineffective Teachers; Will It Be Different in Indiana?

    ERIC Educational Resources Information Center

    Olin, Harlod E.

    2013-01-01

    It has been widely publicized that approximately 98% of the teachers in the United States are rated as satisfactory (Weisberg, Sexton, Mulhern, & Keeling, 2009). This has led many Americans to think that there are very few ineffective teachers in the United States. But is this true? This study indicated that a majority of the principals in the…

  8. Preparing School Leaders for Young Learners in the United States

    ERIC Educational Resources Information Center

    Mongillo, Maria Boeke

    2017-01-01

    In the United States there has been a recent movement to expand access to preschool for children aged 3 to 4 through "universal pre-k" in states that fund programs for all age-eligible students. This has caused an increasing number of preschool programs to be housed in public schools and led by principals who often have little or no…

  9. Embedding Key Transferable Employability Skills for Lifelong Success through Blending an Innovative Portfolio to Complement Traditional Assessment

    ERIC Educational Resources Information Center

    Hooker, Joanne; Whistance, Jayne

    2016-01-01

    Southampton Solent University has been running the unit ENG195 Applied and Academic English Advanced for international students since 2008 as part of the Institution-Wide Language Programme. Following the implementation of a new employability strategy in 2013, the unit was revalidated in July 2014, which led to a major redesign of the curriculum…

  10. Integrating Partner Nations into Coalition Operations

    DTIC Science & Technology

    2006-01-01

    of United Nations (UN) Security Council Resolu- tion 1529, Chile , Canada, France, and the United States established a multinational force...of restabi- lization. Chile continues to deploy forces as a member of the UN Stabilization Force Haiti (MINUSTAH), led by Brazil and comprised...supporting a tailored exercise and theater security cooperation program that has encouraged partners such as Chile , Brazil, and El Salvador to develop

  11. Hearing the Difference: "Mockingbird" Novel Inspires Student-Led Anti-Racism Video Project

    ERIC Educational Resources Information Center

    Coe, Cindy A.

    2017-01-01

    In this article, Cindy Coe describes how after wrapping up her eighth grade "To Kill a Mockingbird" unit, one of her students came to her about derogatory terms being used around school and expressed that she wanted to do something about it in light of their recent unit. In a meeting with the principal, the student shared her frustration…

  12. Higher Education, the Universities and Secondary Teacher Training in Papua New Guinea

    ERIC Educational Resources Information Center

    Palmer, W. P.

    1986-01-01

    The purpose of this paper is to trace the growth of secondary and higher education in Papua New Guinea from its beginnings through the United Nations mission led by Sir Hugh Foot in 1962. The mission was most disappointed in the rate of educational progress in the territory of New Guinea which remained under United Nations mandate in the…

  13. Forest responses to increasing aridity and warmth in the southwestern United States

    Treesearch

    P. Williams; C.D. Allen; C.I. Millar; T.W. Swetnam; J. Michaelsen; C.J. Still; S.W. Leavitt

    2010-01-01

    In recent decades, intense droughts, insect outbreaks, and wildfires have led to decreasing tree growth and increasingmortality in many temperate forests. We compared annual tree-ring width data from 1,097 populations in the coterminous United States to climate data and evaluated site-specific tree responses to climate variations throughout the 20th century. For each...

  14. DOE Zero Energy Ready Home Case Study: United Way of Long Island, United Veterans Beacon House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacific Northwest National Laboratory

    United Way of Long Island’s Housing Development Corporation built this 3,719-ft2 two–story, 5-bedroom home in Huntington Station, New York, to the rigorous performance requirements of the U.S. Department of Energy’s Zero Energy Ready Home Program. The home is packed with high-performance features like LED lighting and ENERGY STAR appliances. The asymmetrical, optimally angled roof provides plenty of space for roof-mounted solar panels for electric generation and hot water.

  15. International Jobs and Economic Development Impacts (I-JEDI) Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    International Jobs and Economic Development Impacts (I-JEDI) is a freely available economic model that estimates gross economic impacts from wind, solar, biomass, and geothermal energy projects. Building on a similar model for the United States, I-JEDI was developed by the National Renewable Energy Laboratory under the U.S. government's Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) program to support partner countries in assessing economic impacts of LEDS actions in the energy sector.

  16. Communicating Airpower: Strategic Communication and the United States Air Force Since 9/11

    DTIC Science & Technology

    2008-08-01

    experience in public affairs, although he had recently led the Air Force’s advertising and marketing program. Whether there were qualified public...Eventually, the Air Force mobi - lized a reserve public affairs officer to temporarily assist in the crisis.76 The Air Force–led investigation team did not...www.drudgereportarchives.com/data/ 2007/ 07/5/2007075_2359.htm. 2. Intermarkets, which manages advertising sales for the Drudge Report, claims that on

  17. Absolute calibration of the Agfa Structurix series films at energies between 2.7 and 6.2 keV.

    PubMed

    Lanier, N E; Cowan, J S

    2014-11-01

    Although photo-emulsion technology is many decades old, x-ray film still remains a key asset for diagnosing hydrodynamic features in High-Energy Density (HED) experiments. For decades, the preferred option had been Kodak's direct exposure film. After its discontinuance in 2004, the push to find alternatives began. In many situations, the Agfa Structurix series offers the most favorable substitute, but being new to the HED community, its characterization was lacking. To remedy this, recent experiments, conducted at Brookhaven's National Synchrotron Light Source, provide absolute, monochromatic calibration data for the Agfa Structurix series films at K-shell backlighter energies between 2.7 and 6.2 keV. Absolute response curves are presented for Agfa D8, D7, D4, D4sc, D3, and D2. Moreover, the transmission of each film type is also measured.

  18. Defect-induced mix experiment for NIF

    NASA Astrophysics Data System (ADS)

    Schmitt, M. J.; Bradley, P. A.; Cobble, J. A.; Hsu, S. C.; Krasheninnikova, N. S.; Kyrala, G. A.; Magelssen, G. R.; Murphy, T. J.; Obrey, K. A.; Tregillis, I. L.; Wysocki, F. J.; Finnegan, S. M.

    2013-11-01

    The Defect Induced Mix Experiment (DIME-II) will measure the implosion and mix characteristics of CH capsules filled with 5 atmospheres of DT by incorporating mid-Z dopant layers of Ge and Ga. This polar direct drive (PDD) experiment also will demonstrate the filling of a CH capsule at target chamber center using a fill tube. Diagnostics for these experiments include areal x-ray backlighting to obtain early time images of the implosion trajectory and a multiple-monochromatic imager (MMI) to collect spectrally-resolved images of the capsule dopant line emission near bangtime. The inclusion of two (or more) thin dopant layers at separate depths within the capsule shell facilitates spatial correlation of mix between the layers and the hot gas core on a single shot. The dopant layers are typically 2 μm thick and contain dopant concentrations of 1.5%. Three dimensional Hydra simulations have been performed to assess the effects of PDD asymmetry on capsule performance.

  19. K-shell photoabsorption edge of strongly coupled aluminum driven by laser-converted radiation

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Zhang, Zhiyu; Qing, Bo; Yang, Jiamin; Zhang, Jiyan; Wei, Minxi; Yang, Guohong; Song, Tianming; Xiong, Gang; Lv, Min; Hu, Zhimin; Deng, Bo; Hu, Xin; Zhang, Wenhai; Shang, Wanli; Hou, Lifei; Du, Huabing; Zhan, Xiayu; Yu, Ruizhen

    2017-03-01

    The first observation of the K-shell photoabsorption edge of strongly coupled aluminum generated by intense x-ray radiation-driven shocks is reported. By using a “dog bone” gold hohlraum as an x-ray converter, colliding shocks compression and preheating shielding are achieved to generate an unexplored state with a density of 5.5 g/cm3 and temperature of 0.43 eV (the ion-ion coupling parameter Γii is around 240). The time-resolved K-shell photoabsorption edges are measured with a crystal spectrometer using a short x-ray backlighter. The broadenings and redshifts of the edges are studied by using the slope fitting of the edge and quantum molecular dynamics calculations. This work shows that the K-edge of aluminum driven by laser-converted radiation provides a novel capability to probe WDM at extended conditions.

  20. Investigation into the electromagnetic impulses from long-pulse laser illuminating solid targets inside a laser facility

    NASA Astrophysics Data System (ADS)

    Yi, Tao; Yang, Jinwen; Yang, Ming; Wang, Chuanke; Yang, Weiming; Li, Tingshuai; Liu, Shenye; Jiang, Shaoen; Ding, Yongkun; Xiao, Shaoqiu

    2016-09-01

    Emission of the electromagnetic pulses (EMP) due to laser-target interaction in laser facility had been evaluated using a cone antenna in this work. The microwave in frequencies ranging from several hundreds of MHz to 2 GHz was recorded when long-pulse lasers with several thousands of joules illuminated the solid targets, meanwhile the voltage signals from 1 V to 4 V were captured as functions of laser energy and backlight laser, where the corresponding electric field strengths were obtained by simulating the cone antenna in combination with conducting a mathematical process (Tiknohov Regularization with L curve). All the typical coupled voltage oscillations displayed multiple peaks and had duration of up to 80 ns before decaying into noise and mechanisms of the EMP generation was schematically interpreted in basis of the practical measuring environments. The resultant data were expected to offer basic know-how to achieve inertial confinement fusion.

  1. On-demand stereoscopic 3D displays for avionic and military applications

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri; Lu, Kanghua; Larson, Brent; Schmidt, John; Cupero, Frank

    2010-04-01

    High speed AM LCD flat panels are evaluated for use in Field Sequential Stereoscopic (FSS) 3D displays for military and avionic applications. A 120 Hz AM LCD is used in field-sequential mode for constructing eyewear-based as well as autostereoscopic 3D display demonstrators for test and evaluation. The COTS eyewear-based system uses shutter glasses to control left-eye/right-eye images. The autostereoscopic system uses a custom backlight to generate illuminating pupils for left and right eyes. It is driven in synchronization with the images on the LCD. Both displays provide 3D effect in full-color and full-resolution in the AM LCD flat panel. We have realized luminance greater than 200 fL in 3D mode with the autostereoscopic system for sunlight readability. The characterization results and performance attributes of both systems are described.

  2. Light beam shaping for collimated emission from white organic light-emitting diodes using customized lenticular microlens arrays structure

    NASA Astrophysics Data System (ADS)

    Zhou, Lei; Bai, Gui-Lin; Guo, Xin; Shen, Su; Ou, Qing-Dong; Fan, Yuan-Yuan

    2018-05-01

    We present a design approach to realizing a desired collimated planar incoherent light source (CPILS) by incorporating lenticular microlens arrays (LMLAs) onto the substrates of discrete white organic light-emitting diode (WOLED) light sources and demonstrate the effectiveness of this method in collimated light beam shaping and luminance enhancement simultaneously. The obtained collimated WOLED light source shows enhanced luminance by a factor of 2.7 compared with that of the flat conventional device at the normal polar angle and, more importantly, exhibits a narrowed angular emission with a full-width at half-maximum (FWHM) of ˜33.6°. We anticipate that the presented strategy could provide an alternative way for achieving the desired large scale CPILS, thereby opening the door to many potential applications, including LCD backlights, three-dimensional displays, car headlights, and so forth.

  3. Structurally integrated fiber optic damage assessment system for composite materials.

    PubMed

    Measures, R M; Glossop, N D; Lymer, J; Leblanc, M; West, J; Dubois, S; Tsaw, W; Tennyson, R C

    1989-07-01

    Progress toward the development of a fiber optic damage assessment system for composite materials is reported. This system, based on the fracture of embedded optical fibers, has been characterized with respect to the orientation and location of the optical fibers in the composite. Together with a special treatment, these parameters have been tailored to yield a system capable of detecting the threshold of damage for various impacted Kevlar/epoxy panels. The technique has been extended to measure the growth of a damage region which could arise from either impact, manufacturing flaws, or static overloading. The mechanism of optical fiber fracture has also been investigated. In addition, the influence of embedded optical fibers on the tensile and compressive strength of the composite material has been studied. Image enhanced backlighting has been shown to be a powerful and convenient method of assessing internal damage to translucent composite materials.

  4. Pluto Majestic Mountains, Frozen Plains and Foggy Hazes

    NASA Image and Video Library

    2015-09-17

    Just 15 minutes after its closest approach to Pluto on July 14, 2015, NASA's New Horizons spacecraft looked back toward the sun and captured this near-sunset view of the rugged, icy mountains and flat ice plains extending to Pluto's horizon. The smooth expanse of the informally named icy plain Sputnik Planum (right) is flanked to the west (left) by rugged mountains up to 11,000 feet (3,500 meters) high, including the informally named Norgay Montes in the foreground and Hillary Montes on the skyline. To the right, east of Sputnik, rougher terrain is cut by apparent glaciers. The backlighting highlights more than a dozen layers of haze in Pluto's tenuous but distended atmosphere. The image was taken from a distance of 11,000 miles (18,000 kilometers) to Pluto; the scene is 780 miles (1,250 kilometers) wide. http://photojournal.jpl.nasa.gov/catalog/PIA19948

  5. Temperature in subsonic and supersonic radiation fronts measured at OMEGA

    NASA Astrophysics Data System (ADS)

    Johns, Heather; Kline, John; Lanier, Nick; Perry, Ted; Fontes, Chris; Fryer, Chris; Brown, Colin; Morton, John

    2017-10-01

    Propagation of heat fronts relevant to astrophysical plasmas is challenging in the supersonic regime. Plasma Te changes affect opacity and equation of state without hydrodynamic change. In the subsonic phase density perturbations form at material interfaces as the plasma responds to radiation pressure of the front. Recent experiments at OMEGA studied this transition in aerogel foams driven by a hohlraum. In COAX, two orthogonal backlighters drive x-ray radiography and K-shell absorption spectroscopy to diagnose the subsonic shape of the front and supersonic Te profiles. Past experiments used absorption spectroscopy in chlorinated foams to measure the heat front; however, Cl dopant is not suitable for higher material temperatures at NIF. COAX has developed use of Sc and Ti dopants to diagnose Te between 60-100eV and 100-180eV. Analysis with PrismSPECT using OPLIB tabular opacity data will evaluate the platform's ability to advance radiation transport in this regime.

  6. Design and engineering of a target for x-ray Thomson scattering measurements on matter at extreme densities and gigabar pressures

    DOE PAGES

    Boehm, K. -J.; Hash, N.; Barker, D.; ...

    2016-06-24

    Reconciling the experimental and system requirements during the development of a new target system is one of the most challenging tasks in the design and engineering of targets used in the National Ignition Facility. Targets for the GigaBar 3 campaign were meant to allow the detection of extremely weak Thomson scattering from matter at extreme densities in the face of very bright backlighter and laser entry hole plasma emissions. The problem was to shield the detector sufficiently while maintaining beamline and view clearances, and observing target mass restrictions. A new construction process, based on a rapid prototype frame structure, wasmore » used to develop this target. As a result, details of the design process for these targets are described, and lessons from this development for production and target assembly teams are discussed.« less

  7. Non-Toxic Gold Nanoclusters for Solution-Processed White Light-Emitting Diodes.

    PubMed

    Chao, Yu-Chiang; Cheng, Kai-Ping; Lin, Ching-Yi; Chang, Yu-Li; Ko, Yi-Yun; Hou, Tzu-Yin; Huang, Cheng-Yi; Chang, Walter H; Lin, Cheng-An J

    2018-06-11

    Solution-processed optoelectronic devices are attractive because of the potential low-cost fabrication and the compatibility with flexible substrate. However, the utilization of toxic elements such as lead and cadmium in current optoelectronic devices on the basis of colloidal quantum dots raises environmental concerns. Here we demonstrate that white-light-emitting diodes can be achieved by utilizing non-toxic and environment-friendly gold nanoclusters. Yellow-light-emitting gold nanoclusters were synthesized and capped with trioctylphosphine. These gold nanoclusters were then blended with the blue-light-emitting organic host materials to form the emissive layer. A current efficiency of 0.13 cd/A was achieved. The Commission Internationale de l'Eclairage chromaticity coordinates of (0.27, 0.33) were obtained from our experimental analysis, which is quite close to the ideal pure white emission coordinates (0.33, 0.33). Potential applications include innovative lighting devices and monitor backlight.

  8. Absolute calibration of the Agfa Structurix series films at energies between 2.7 and 6.2 keVa)

    NASA Astrophysics Data System (ADS)

    Lanier, N. E.; Cowan, J. S.

    2014-11-01

    Although photo-emulsion technology is many decades old, x-ray film still remains a key asset for diagnosing hydrodynamic features in High-Energy Density (HED) experiments. For decades, the preferred option had been Kodak's direct exposure film. After its discontinuance in 2004, the push to find alternatives began. In many situations, the Agfa Structurix series offers the most favorable substitute, but being new to the HED community, its characterization was lacking. To remedy this, recent experiments, conducted at Brookhaven's National Synchrotron Light Source, provide absolute, monochromatic calibration data for the Agfa Structurix series films at K-shell backlighter energies between 2.7 and 6.2 keV. Absolute response curves are presented for Agfa D8, D7, D4, D4sc, D3, and D2. Moreover, the transmission of each film type is also measured.

  9. 3D integrated HYDRA simulations of hohlraums including fill tubes

    NASA Astrophysics Data System (ADS)

    Marinak, M. M.; Milovich, J.; Hammel, B. A.; Macphee, A. G.; Smalyuk, V. A.; Kerbel, G. D.; Sepke, S.; Patel, M. V.

    2017-10-01

    Measurements of fill tube perturbations from hydro growth radiography (HGR) experiments on the National Ignition Facility show spoke perturbations in the ablator radiating from the base of the tube. These correspond to the shadow of the 10 μm diameter glass fill tube cast by hot spots at early time. We present 3D integrated HYDRA simulations of these experiments which include the fill tube. Meshing techniques are described which were employed to resolve the fill tube structure and associated perturbations in the simulations. We examine the extent to which the specific illumination geometry necessary to accommodate a backlighter in the HGR experiment contributes to the spoke pattern. Simulations presented include high resolution calculations run on the Trinity machine operated by the Alliance for Computing at Extreme Scale (ACES) partnership. This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344.

  10. Study of the hydrodynamics of the formation of flows caused by the interaction of a shock wave with two-dimensional density perturbations on the Iskra-5 laser facility

    NASA Astrophysics Data System (ADS)

    Babanov, A. V.; Barinov, M. A.; Barinov, S. P.; Garanin, R. V.; Zhidkov, N. V.; Kalmykov, N. A.; Kovalenko, V. P.; Kokorin, S. N.; Pinegin, A. V.; Solomatina, E. Yu.; Solomatin, I. I.; Suslov, N. A.

    2017-03-01

    The hydrodynamics of the flow formation due to the interaction of a shock wave with two-dimensional density perturbations is experimentally investigated on the Iskra-5 laser facility. Shadow images of a jet arising as a result of the impact of a shock wave (formed by a soft X-ray pulse from a target-illuminator) on a flat aluminium target with a blind cylindrical cavity are recorded in experiments with point-like X-ray backlighting having a photon energy of ~4.5 keV. The sizes and mass of the jet ejected from the aluminium cavity by this shock wave are estimated. The experimental data are compared with the results of numerical simulation of the jet formation and dynamics according to the two-dimensional MID-ND2D code.

  11. Collapsing Radiative Shocks in Xenon Gas on the Omega Laser

    NASA Astrophysics Data System (ADS)

    Reighard, A. B.; Glendinning, S. G.; Knauer, J.; Bouquet, S.; Koenig, M.

    2005-10-01

    A number of astrophysical systems involve radiative shocks that collapse spatially in response to energy lost through radiation, producing thin shells believed to be Vishniac unstable. We report experiments intended to study such collapsing shocks. The Omega laser drives a thin slab of material at >100 km/s through Xe gas. Simulations predict a collapsed layer in which the density reaches 45 times initial density. X-ray backlighting techniques have yielded images of a collapsed shock compressed to <1/25 its initial thickness (45 μm) at a speed of ˜100 km/s when the shock has traveled 1.3 mm. Optical depth before and behind the shock is important for comparison to astrophysical systems. This research was sponsored by the National Nuclear Security Administration under the Stewardship Science Academic Alliances program through DOE Research Grants DE-FG52-03NA00064, DE-FG53-2005-NA26014, and other grants and contracts.

  12. Monochromatic x-ray radiography for areal-density measurement of inertial fusion energy fuel in fast ignition experiment.

    PubMed

    Fujioka, Shinsuke; Fujiwara, Takashi; Tanabe, Minoru; Nishimura, Hiroaki; Nagatomo, Hideo; Ohira, Shinji; Inubushi, Yuichi; Shiraga, Hiroyuki; Azechi, Hiroshi

    2010-10-01

    Ultrafast, two-dimensional x-ray imaging is an important diagnostics for the inertial fusion energy research, especially in investigating implosion dynamics at the final stage of the fuel compression. Although x-ray radiography was applied to observing the implosion dynamics, intense x-rays emitted from the high temperature and dense fuel core itself are often superimposed on the radiograph. This problem can be solved by coupling the x-ray radiography with monochromatic x-ray imaging technique. In the experiment, 2.8 or 5.2 keV backlight x-rays emitted from laser-irradiated polyvinyl chloride or vanadium foils were selectively imaged by spherically bent quartz crystals with discriminating the out-of-band emission from the fuel core. This x-ray radiography system achieved 24 μm and 100 ps of spatial and temporal resolutions, respectively.

  13. Effect of microbubble-induced cavitation on the dispersion of sprays

    NASA Astrophysics Data System (ADS)

    van der Voort, D. D.; Dam, N. J.; Kunnen, R. P. J.; van Heijst, G. J. F.; Clercx, H. J. H.

    2017-03-01

    The presence of bubbles and voids inside nozzles has a large effect on the morphology and atomization of sprays. In this investigation the voids formed by microbubbles entering the nozzle are investigated using transparent glass nozzles, pressure transducers, and high-speed diffuse backlight imaging. A correlation is found between the magnitude of pressure pulses inside the nozzle and the size of the bubbles causing these pulses. This relation allows the prediction of cavity formation also in nontransparent nozzles, which allow more realistic conditions of operation. Subsequently, the direct measurements of dispersion derived from the spread of glowing fluid showed no significant increase of the dispersion compared to cavitation-free conditions. This indicates that, while the spray angle may increase, the turbulence (in both liquid and gas phase) that governs the dispersion remains the same and the cavitation bubble events do not have a significant impact on this process.

  14. Enhancing light emission in flexible AC electroluminescent devices by tetrapod-like zinc oxide whiskers.

    PubMed

    Wen, Li; Liu, Nishuang; Wang, Siliang; Zhang, Hui; Zhao, Wanqiu; Yang, Zhichun; Wang, Yumei; Su, Jun; Li, Luying; Long, Fei; Zou, Zhengguang; Gao, Yihua

    2016-10-03

    Flexible alternating current electroluminescent devices (ACEL) are more and more popular and widely used in liquid-crystal display back-lighting, large-scale architectural and decorative lighting due to their uniform light emission, low power consumption and high resolution. However, presently how to acquire high brightness under a certain voltage are confronted with challenges. Here, we demonstrate an electroluminescence (EL) enhancing strategy that tetrapod-like ZnO whiskers (T-ZnOw) are added into the bottom electrode of carbon nanotubes (CNTs) instead of phosphor layer in flexible ACEL devices emitting blue, green and orange lights, and the brightness is greatly enhanced due to the coupling between the T-ZnOw and ZnS phosphor dispersed in the flexible polydimethylsiloxane (PDMS) layer. This strategy provides a new routine for the development of high performance, flexible and large-area ACEL devices.

  15. Observable Protein Crystal Growth Apparatus

    NASA Technical Reports Server (NTRS)

    2001-01-01

    This diagram shows a cross sectrion of the fluid volume of an individual cell in the Observable Protein Crystal Growth Apparatus (OPCGA) to be operated aboard the International Space Station (ISS). The principal investigator is Dr. Alex McPherson of the University of California, Irvine. Each individual cell comprises two sample chambers with a rotating center section that isolates the two from each other until the start of the experiment and after it is completed. The cells are made from optical-quality quartz glass to allow photography and interferometric observations. Each cell has a small light-emitting diode and lens to back-light the solution. In protein crystal growth experiments, a precipitating agent such as a salt solution is used to absorb and hold water but repel the protein molecules. This increases the concentration of protein until the molecules nucleate to form crystals. This cell is one of 96 that make up the experiment module portion of the OPCGA.

  16. High-energy (>70 keV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; Martinez, D. A.; Di Nicola, P.; Tommasini, R.; Landen, O. L.; Alessi, D.; Bowers, M.; Browning, D.; Brunton, G.; Budge, T.; Crane, J.; Di Nicola, J.-M.; Döppner, T.; Dixit, S.; Erbert, G.; Fishler, B.; Halpin, J.; Hamamoto, M.; Heebner, J.; Hernandez, V. J.; Hohenberger, M.; Homoelle, D.; Honig, J.; Hsing, W.; Izumi, N.; Khan, S.; LaFortune, K.; Lawson, J.; Nagel, S. R.; Negres, R. A.; Novikova, L.; Orth, C.; Pelz, L.; Prantil, M.; Rushford, M.; Shaw, M.; Sherlock, M.; Sigurdsson, R.; Wegner, P.; Widmayer, C.; Williams, G. J.; Williams, W.; Whitman, P.; Yang, S.

    2017-03-01

    The Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20-30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4-9 × 10-4 for x-rays with energies greater than 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.

  17. Citrus fruit recognition using color image analysis

    NASA Astrophysics Data System (ADS)

    Xu, Huirong; Ying, Yibin

    2004-10-01

    An algorithm for the automatic recognition of citrus fruit on the tree was developed. Citrus fruits have different color with leaves and branches portions. Fifty-three color images with natural citrus-grove scenes were digitized and analyzed for red, green, and blue (RGB) color content. The color characteristics of target surfaces (fruits, leaves, or branches) were extracted using the range of interest (ROI) tool. Several types of contrast color indices were designed and tested. In this study, the fruit image was enhanced using the (R-B) contrast color index because results show that the fruit have the highest color difference among the objects in the image. A dynamic threshold function was derived from this color model and used to distinguish citrus fruit from background. The results show that the algorithm worked well under frontlighting or backlighting condition. However, there are misclassifications when the fruit or the background is under a brighter sunlight.

  18. LED photochemotherapy against Staphylococcus aureus: an in vitro study

    NASA Astrophysics Data System (ADS)

    de Oliveira, Susana C. P. S.; Monteiro, Juliana S. C.; Pires-Santos, Gustavo M.; Sampaio, Fernando José Pires; Soares, Luiz Guilherme P.; Soares, Amanda P.; Pinheiro, Antônio L. B.

    2018-02-01

    Bacterial resistance to antibiotics is reality and need for alternative treatments is urgent. The aim of this work was to evaluate, in vitro, the effect of LED photochemotherapy on Staphylococcus aureus (ATCC 23529) using 25 μg / mL of phenothiazine compound combined with LED light (λ632 +/- 2ηm) using 12 J/cm2 energy density. The experiments were carried out in triplicate and the samples were divided into groups: Control, Irradiated (treated only with light), Photosensitizer (treated only in the presence of the dye), LED-Photochemotherapy (treatment with light associated with dye). Counts of the colony forming units and the data obtained were statistically analyzed (ANOVA, Tukey's test, p<0.05). The present study demonstrated that the efficacy of LED-Photochemotherapy as the use of 25 μg/mL x 12 J/cm2 caused 91.57 % of inhibition of bacterial growth. It is concluded that using energy density of 12 J/cm2 associated to 25 μg/mL caused high in vitro inhibition of S. aureus.

  19. Nano-enabled paper humidity sensor for mobile based point-of-care lung function monitoring.

    PubMed

    Bhattacharjee, Mitradip; Nemade, Harshal B; Bandyopadhyay, Dipankar

    2017-08-15

    The frequency of breathing and peak flow rate of exhaled air are necessary parameters to detect chronic obstructive pulmonary diseases (COPDs) such as asthma, bronchitis, or pneumonia. We developed a lung function monitoring point-of-care-testing device (LFM-POCT) consisting of mouthpiece, paper-based humidity sensor, micro-heater, and real-time monitoring unit. Fabrication of a mouthpiece of optimal length ensured that the exhaled air was focused on the humidity-sensor. The resistive relative humidity sensor was developed using a filter paper coated with nanoparticles, which could easily follow the frequency and peak flow rate of the human breathing. Adsorption followed by condensation of the water molecules of the humid air on the paper-sensor during the forced exhalation reduced the electrical resistance of the sensor, which was converted to an electrical signal for sensing. A micro-heater composed of a copper-coil embedded in a polymer matrix helped in maintaining an optimal temperature on the sensor surface. Thus, water condensed on the sensor surface only during forcible breathing and the sensor recovered rapidly after the exhalation was complete by rapid desorption of water molecules from the sensor surface. Two types of real-time monitoring units were integrated into the device based on light emitting diodes (LEDs) and smart phones. The LED based unit displayed the diseased, critical, and fit conditions of the lungs by flashing LEDs of different colors. In comparison, for the mobile based monitoring unit, an application was developed employing an open source software, which established a wireless connectivity with the LFM-POCT device to perform the tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Comparison of UV-LED and low pressure UV for water disinfection: Photoreactivation and dark repair of Escherichia coli.

    PubMed

    Li, Guo-Qiang; Wang, Wen-Long; Huo, Zheng-Yang; Lu, Yun; Hu, Hong-Ying

    2017-12-01

    Studies on ultraviolet light-emitting diode (UV-LED) water disinfection have shown advantages, such as safety, flexible design, and lower starting voltages. However, information about reactivation after UV-LED disinfection is limited, which is an important issue of UV light-based technology. In this study, the photoreactivation and dark repair of Escherichia coli after UV-LEDs and low pressure (LP) UV disinfection were compared. Four UV-LED units, 265 nm, 280 nm, the combination of 265 + 280 (50%), and 265 + 280 (75%) were tested. 265 nm LEDs was more effective than 280 nm LEDs and LP UV lamps for E. coli inactivation. No synergic effect for disinfection was observed from the combination of 265 and 280 nm LEDs. 265 nm LEDs had no different reactivation performances with that of LP UV, while 280 nm LEDs could significantly repress photoreactivation and dark repair at a low irradiation intensity of 6.9 mJ/cm 2 . Furthermore, the UV-induced damage of 280 nm LEDs was less repaired which was determined by endonuclease sensitive site (ESS) assay. The impaired protein activities by 280 nm LEDs might be one of the reasons that inhibited reactivation. A new reactivation rate constant, K max , was introduced into the logistic model to simulate the reactivation data, which showed positive relationship with the maximum survival ratio and was more reasonable to interpret the results of photoreactivation and dark repair. This study revealed the distinct roles of different UV lights in disinfection and reactivation, which is helpful for the future design of UV-LED equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Cure width potential for MOD resin composite molar restorations.

    PubMed

    Palin, William M; Senyilmaz, Dilek P; Marquis, Peter M; Shortall, Adrian C

    2008-08-01

    To investigate the capability of modern light-curing units exhibiting differences in emission spectra and light source exit window dimensions, for "one-shot" full-width curing of extensive (molar MOD) resin composite restorations. Specimens of Tetric (TT), Tetric Ceram HB (TC), Tetric Evoceram (TE) and Tetric Ceram Bleach (TB) resin composites containing varying ratios of Lucirin (TPO) and/or camphorquinone (CQ) photoinitiators were packed into a bar-shaped mould (12 mm length x 2 mm width x 2 mm thickness). Each product was irradiated using a halogen (Optilux 401; QTH), a conventional LED (LEDemetron; LED) and two so-called "third generation" oval-footprint LED light-curing units (LCUs) of the same model. The latter featured bimodal emission spectra (blue and ultraviolet diodes) with either high (unmodified output) and approximately 50% (modified output) blue light intensity (UltraLume-5; ULs, ULm, respectively). Vickers hardness number was obtained across the lateral extent of the bar at 1mm increments from the centre point on both upper and lower surfaces of the specimens. Significant linear relationships (R(2)=0.71-0.98) for each distance from the central position of all LCUs were identified between measured light intensity and corresponding upper and lower surface hardness values for each product (P<0.05). No significant differences (P>0.05) were recorded in total upper surface hardness of TC or TE cured with LED (68.7+/-3.2 and 70.5+/-2.5) or ULm (56.8+/-2.0 and 57.7+/-2.0). However, upper surface hardness of TT (CQ only) cured with ULm was significantly decreased (P<0.05) compared with other LCUs. When the ratio of hardness at the edge to central positions of the bar-shaped specimens for either surface was calculated, no significant difference (P>0.05) was identified for TB (containing TPO and decreased CQ) cured with either ULs or ULm (P>0.05) and was significantly increased (P<0.05) when cured with ULs compared with LED and QTH. Variability in light intensity across the curing-tip face, spectral output of dental light-curing units and differences in product photoinitiator chemistry all influence curing efficiency significantly across the width of extensive resin composite geometries.

  2. Novel insights into the elm yellows phytoplasma genome and into the metagenome of elm yellows-infected elms

    Treesearch

    Christina Rosa; Paolo Margaria; Scott M. Geib; Erin D. Scully

    2017-01-01

    In North America, American elms were historically present throughout the northeastern United States and southeastern Canada. The longevity of these trees, their resistance to the harsh urban environment, and their aesthetics led to their wide use in landscaping and streetscaping over several decades. American elms were one of most cultivated plants in the United States...

  3. Effects of nitrogen deposition and empirical nitrogen critical loads for ecoregions of the United States

    Treesearch

    Linda H. Pardo; Mark E. Fenn; Christine L. Goodale; Linda H. Geiser; Charles T. Driscoll; Edith B. Allen; Jill S. Baron; Roland Bobbink; William D. Bowman; Christopher M. Clark; Bridget Emmett; Frank S. Gilliam; Tara L. Greaver; Sharon J. Hall; Erik A. Lilleskov; Lingli Liu; Jason A. Lynch; Knute J. Nadelhoffer; Steven S. Perakis; Molly J. Robin-Abbott; John L. Stoddard; Kathleen C. Weathers; Robin L. Dennis

    2011-01-01

    Human activity in the last century has led to a significant increase in nitrogen (N) emissions and atmospheric deposition. This N deposition has reached a level that has caused or is likely to cause alterations to the structure and function of many ecosystems across the United States. One approach for quantifying the deposition of pollution that would be harmful to...

  4. Moving from the Periphery to the Center of the Academy: Faculty Developers as Leaders of Change

    ERIC Educational Resources Information Center

    Dawson, Debra; Mighty, Joy; Britnell, Judy

    2010-01-01

    Faculty development units have been in existence in North American universities and colleges for more than forty years. The early faculty development units were typically led by a committee or a part-time director who focused on presenting teaching tips in short workshops. Over the years, the role of these centers gradually evolved as they became…

  5. Effects and empirical critical loads of nitrogen for ecoregions of the United States

    Treesearch

    Linda H. Pardo; Molly J. Robin-Abbot; Mark E. Fenn; Christine L. Goodale; Linda H. Geiser; Charles T. Driscoll; Edith B. Allen; Jill S. Baron; Roland Bobbink; William D. Bowman; Christopher M. Clark; Bridget Emmett; Frank S. Gilliam; Tara L. Greaver; Sharon J. Hall; Erik A. Lilleskov; Lingli Liu; Jason A. Lynch; Knute J. Nadelhoffer; Steven J. Perakis; John L. Stoddard; Kathleen C. Weathers; Robin L. Dennis

    2015-01-01

    Human activity in the last century has led to a significant increase in nitrogen (N) emissions and deposition (Galloway et al. 2004). Total N emissions in the United States have increased significantly since the 1950s (Galloway 1998, Galloway et al. 2003). As S deposition has declined in response to regulation, the rate of N deposition relative to S deposition has...

  6. Invasion dynamics of white-nose syndrome fungus, midwestern United States, 2012-2014.

    PubMed

    Langwig, Kate E; Hoyt, Joseph R; Parise, Katy L; Kath, Joe; Kirk, Dan; Frick, Winifred F; Foster, Jeffrey T; Kilpatrick, A Marm

    2015-06-01

    White-nose syndrome has devastated bat populations in eastern North America. In Midwestern United States, prevalence increased quickly in the first year of invasion (2012-13) but with low population declines. In the second year (2013-14), environmental contamination led to earlier infection and high population declines. Interventions must be implemented before or soon after fungal invasion to prevent population collapse.

  7. Harvesting choices and timber supply among landowners in the southern United States

    Treesearch

    Daowei Zhang; Xing Sun; Brett J. Butler; Jeffrey P. Prestemon

    2015-01-01

    The recent rise of institutional timberland ownership has led to a significant change in the structure and conduct of the timber industry in the United States. In this study,we apply a two-period harvest model to assess the timber harvesting behavior of various landowners at the stand level by utilizing USDA Forest Service Forest Inventory and Analysis data for nine...

  8. Pragmatism and the Unlikely Influence of German Idealism on the Academy in the United States

    ERIC Educational Resources Information Center

    Ream, Todd C.

    2007-01-01

    In this article I argue that the subject-object distinction, operative in Continental Europe during the late-1700s and early-1800s, led to the religion-secular distinction in higher education in the United States. Many scholars believe the origins of the shifting nature of the religion-secular distinction resided with some form of influence that…

  9. Motor unit recruitment patterns 1: responses to changes in locomotor velocity and incline.

    PubMed

    Hodson-Tole, Emma F; Wakeling, James M

    2008-06-01

    Mammalian skeletal muscles are composed of a mixture of motor unit types, which contribute a range of mechanical and physiological properties to the muscle. For a muscle to effectively contribute to smooth, co-ordinated movement it must activate an appropriate number and combination of motor units to generate the required force over a suitable time period. Much evidence exists indicating that motor units are activated in an orderly fashion, from the slowest through to the fastest. A growing body of evidence, however, indicates that such a recruitment strategy does not always hold true. Here we investigate how motor unit recruitment patterns were influenced by changes in locomotor velocity and incline. Kinematics data and myoelectric signals were collected from three rat ankle extensor muscles during running on a treadmill at nine velocity and incline combinations. Wavelet and principal component analysis were used to simultaneously decompose the signals into time and frequency space. The relative frequency components of the signals were quantified during 20 time windows of a stride from each locomotor condition. Differences in signal frequency components existed between muscles and locomotor conditions. Faster locomotor velocities led to a relative increase in high frequency components, whereas greater inclines led to a relative increase in the low frequency components. These data were interpreted as representing changes in motor unit recruitment patterns in response to changes in the locomotor demand. Motor units were not always recruited in an orderly manner, indicating that recruitment is a multi-factorial phenomenon that is not yet fully understood.

  10. The National Radon Action Plan - A Strategy for Saving Lives

    EPA Pesticide Factsheets

    This Plan represents a collaborative effort between eleven organizations dedicated to eliminating avoidable radon-induced lung cancer in the United States. This partnership is led by the American Lung Association.

  11. Public/private partnerships for prescription drug coverage: policy formulation and outcomes in Quebec's universal drug insurance program, with comparisons to the Medicare prescription drug program in the United States.

    PubMed

    Pomey, Marie-Pascale; Forest, Pierre-Gerlier; Palley, Howard A; Martin, Elisabeth

    2007-09-01

    In January 1997, the government of Quebec, Canada, implemented a public/private prescription drug program that covered the entire population of the province. Under this program, the public sector collaborates with private insurers to protect all Quebecers from the high cost of drugs. This article outlines the principal features and history of the Quebec plan and draws parallels between the factors that led to its emergence and those that led to the passage of the Medicare Prescription Drug, Improvement and Modernization Act (MMA) in the United States. It also discusses the challenges and similarities of both programs and analyzes Quebec's ten years of experience to identify adjustments that may help U.S. policymakers optimize the MMA.

  12. Public/Private Partnerships for Prescription Drug Coverage: Policy Formulation and Outcomes in Quebec's Universal Drug Insurance Program, with Comparisons to the Medicare Prescription Drug Program in the United States

    PubMed Central

    Pomey, Marie-Pascale; Forest, Pierre-Gerlier; Palley, Howard A; Martin, Elisabeth

    2007-01-01

    In January 1997, the government of Quebec, Canada, implemented a public/private prescription drug program that covered the entire population of the province. Under this program, the public sector collaborates with private insurers to protect all Quebecers from the high cost of drugs. This article outlines the principal features and history of the Quebec plan and draws parallels between the factors that led to its emergence and those that led to the passage of the Medicare Prescription Drug, Improvement and Modernization Act (MMA) in the United States. It also discusses the challenges and similarities of both programs and analyzes Quebec's ten years of experience to identify adjustments that may help U.S. policymakers optimize the MMA. PMID:17718665

  13. Effect of light-curing units on microleakage under dental composite resins

    NASA Astrophysics Data System (ADS)

    Queiroz, R. S.; Bandéca, M. C.; Calixto, L. R.; Saade, E. G.; Nadalin, M. R.; Andrade, M. F.; Porto-Neto, S. T.

    2009-09-01

    The aim of this study was to determine the effect of two light-curing units (QTH and LED) on microleakage of Class II composite resin restorations with dentin cavosurface margins. Twenty extracted mandibular first premolars, free of caries and fractures were prepared two vertical “slot” cavities in the occluso-mesial and -destal surfaces (2 mm buccal-lingually, 2 mm proximal-axially and cervical limit in enamel) and divided into 4 equal groups ( n = 8): GI and GII: packable posterior composite light-activated with LED and QTH, respectively; GIII and GIV: micro-hybrid composite resin light-activated with LED and QTH, respectively. The composite resins were applied following the manufacturer’s instructions. After 24 h of water storage specimens were subjected to thermocycling for a total of 500 cycles at 5 and 55°C and the teeth were then sealed with impermeable material. Teeth were immersed in 0.5% Basic fuchsin during 24 h at room temperature, and zero to three levels of penetration score were attributed. The Mann-Whitney and Kruskal-Wallis tests showed significant statistically similar ( P > 0.05) from GI to GII and GIII to GIV, which the GII (2.750) had the highest mean scores and the GIII and GIV (0.875) had lowest mean scores. The use of different light-curing units has no influence on marginal integrity of Class II composite resin restorations and the proprieties of composite resins are important to reduce the microleakage.

  14. Influence of light curing and sample thickness on microhardness of a composite resin

    PubMed Central

    Aguiar, Flávio HB; Andrade, Kelly RM; Leite Lima, Débora AN; Ambrosano, Gláucia MB; Lovadino, José R

    2009-01-01

    The aim of this in vitro study was to evaluate the influence of light-curing units and different sample thicknesses on the microhardness of a composite resin. Composite resin specimens were randomly prepared and assigned to nine experimental groups (n = 5): considering three light-curing units (conventional quartz tungsten halogen [QTH]: 550 mW/cm2 – 20 s; high irradiance QTH: 1160 mW/cm2 – 10 s; and light-emitting diode [LED]: 360 mW/cm2 – 40 s) and three sample thicknesses (0.5 mm, 1 mm, and 2 mm). All samples were polymerized with the light tip 8 mm away from the specimen. Knoop microhardness was then measured on the top and bottom surfaces of each sample. The top surfaces, with some exceptions, were almost similar; however, in relation to the bottom surfaces, statistical differences were found between curing units and thicknesses. In all experimental groups, the 0.5-mm-thick increments showed microhardness values statistically higher than those observed for 1- and -2-mm increments. The conventional and LED units showed higher hardness mean values and were statistically different from the high irradiance unit. In all experimental groups, microhardness mean values obtained for the top surface were higher than those observed for the bottom surface. In conclusion, higher levels of irradiance or thinner increments would help improve hybrid composite resin polymerization. PMID:23674901

  15. Pharmacist-led Chronic Disease Management: A Systematic Review of Effectiveness and Harms Compared With Usual Care.

    PubMed

    Greer, Nancy; Bolduc, Jennifer; Geurkink, Eric; Rector, Thomas; Olson, Kimberly; Koeller, Eva; MacDonald, Roderick; Wilt, Timothy J

    2016-04-26

    Increased involvement of pharmacists in patient care may increase access to health care and improve patient outcomes. To determine the effectiveness and harms of pharmacist-led chronic disease management for community-dwelling adults. MEDLINE, Cochrane Library, CINAHL, and International Pharmaceutical Abstracts from 1995 through February 2016, and reference lists of systematic reviews and included studies. 65 patient populations in 63 studies conducted in the United States and of any design reported outcomes of pharmacist-led chronic disease management versus a comparator for community-dwelling adults in the United States. Studies set in retail pharmacies were excluded. Data extraction done by a single investigator was confirmed by a second investigator; risk of bias was assessed by 2 investigators; and strength of evidence was determined by consensus. Pharmacist-led care was associated with similar numbers of office visits, urgent care or emergency department visits, and hospitalizations (moderate-strength evidence) and medication adherence (low-strength evidence) compared with usual care (typically continuing a prestudy visit schedule). Pharmacist-led care increased the number or dose of medications received and improved study-selected glycemic, blood pressure, and lipid goal attainment (moderate-strength evidence). Mortality and clinical events were similar (low-strength evidence). Evidence on patient satisfaction was mixed and insufficient. The reporting of harms was limited. Interventions were heterogeneous. Studies were typically short-term and designed to assess physiologic intermediate outcomes rather than clinical events. Reporting of many clinical outcomes of interest was limited, and often they were not the study-defined primary end points. Pharmacist-led chronic disease management was associated with effects similar to those of usual care for resource utilization and may improve physiologic goal attainment. Further research is needed to determine whether increased medication utilization and goal attainment improve clinical outcomes. Department of Veterans Affairs, Veterans Health Administration, Office of Research and Development, Quality Enhancement Research Initiative.

  16. Effects of blue diode laser (445 nm) and LED (430-480 nm) radiant heat treatments on dental glass ionomer restoratives

    NASA Astrophysics Data System (ADS)

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2018-02-01

    The purpose of this in vitro study was to evaluate the effect of two radiant heat treatments on water sorption, solubility and surface roughness of three conventional glass ionomer cements by using a blue diode laser (445 nm) and a light emitting diode (LED) unit (430-480 nm). Thirty disk-shaped specimens were prepared for each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: Group 1 was the control group, in Group 2 the specimens were irradiated for 60 s at the top surface using a LED light-curing unit and in Group 3 the specimens were irradiated for 60 s at the top surface using a blue light diode laser. Statistical analysis was performed using one-way ANOVA and Tukey post hoc tests at a level of significance of a = 0.05. Radiant heat treatments with both laser and LED devices significantly decreased water sorption and solubility (p < 0.05) of most of the tested GICs. Blue diode laser treatment was seemed to be more effective compared to LED treatment for some of the tested materials. There were no changes in surface roughness of the GICs after the treatments (p > 0.05). Among the tested materials there were differences in water sorption and solubility (p < 0.05) but not in surface roughness (p > 0.05). The use of the blue diode laser for this radiant heat treatment was harmless for the surface of the tested GICs and may be advantageous for the longevity of their restorations.

  17. A high proportion of blue light increases the photosynthesis capacity and leaf formation rate of Rosa × hybrida but does not affect time to flower opening.

    PubMed

    Terfa, Meseret Tesema; Solhaug, Knut Asbjørn; Gislerød, Hans Ragnar; Olsen, Jorunn Elisabeth; Torre, Sissel

    2013-05-01

    Alterations in light quality affect plant morphogenesis and photosynthetic responses but the effects vary significantly between species. Roses exhibit an irradiance-dependent flowering control but knowledge on light quality responses is scarce. In this study we analyzed, the responses in morphology, photosynthesis and flowering of Rosa × hybrida to different blue (B) light proportions provided by light-emitting diodes (LED, high B 20%) and high pressure sodium (HPS, low B 5%) lamps. There was a strong morphological and growth effect of the light sources but no significant difference in total dry matter production and flowering. HPS-grown plants had significantly higher leaf area and plant height, yet a higher dry weight proportion was allocated to leaves than stems under LED. LED plants showed 20% higher photosynthetic capacity (Amax ) and higher levels of soluble carbohydrates. The increase in Amax correlated with an increase in leaf mass per unit leaf area, higher stomata conductance and CO2 exchange, total chlorophyll (Chl) content per area and Chl a/b ratio. LED-grown leaves also displayed a more sun-type leaf anatomy with more and longer palisade cells and a higher stomata frequency. Although floral initiation occurred at a higher leaf number in LED, the time to open flowers was the same under both light conditions. Thereby the study shows that a higher portion of B light is efficient in increasing photosynthesis performance per unit leaf area, enhancing growth and morphological changes in roses but does not affect the total Dry Matter (DM) production or time to open flower. Copyright © Physiologia Plantarum 2012.

  18. Liquid lift for the Shuttle

    NASA Astrophysics Data System (ADS)

    Demeis, Richard

    1989-02-01

    After the operational failure of a Solid Rocket Booster (SRB) led to the Space Shuttle Challenger accident, NASA reexamined the use of liquid-fueled units in place of the SRBs in order to ascertain whether they could improve safety and payload. In view of favorable study results obtained, the posibility has arisen of employing a common liquid rocket booster for the Space Shuttle, its cargo version ('Shuttle-C'), and the next-generation Advanced Launch System. The system envisioned would involve two booster units, whose four engines/unit would be fed by integral LOX and kerosene tanks. Mission aborts with one-booster unit and two-unit failures would not be catastrophic, and would respectively allow LEO or an emergency landing in Africa.

  19. Description and evaluation of a serious game intervention to engage low secure service users with serious mental illness in the design and refurbishment of their environment.

    PubMed

    Fitzgerald, M M; Kirk, G D; Bristow, C A

    2011-05-01

    Service user involvement in all levels of healthcare provision is the expectation of UK government policy. Involvement should not only include participation in the planning and delivery of health care but also the exercise of choice and opinions about that care. In practice, however, service user engagement is most often tokenistic, involving post hoc consultation over plans already committed to by services. This paper explores an Occupational Therapy-led initiative to use the Serious Game format to engage low secure service users with serious mental illness in the design, layout and refurbishment of their unit. Among other things how medication was to be dispensed on the new unit was explored by this game and led to significant replanning in response to service user involvement. The game format was found to be a useful tool in facilitating communication between professionals and a traditionally marginalized and powerless client group. It enabled service users to have a voice, it provided a format for that voice to be heard and made possible service-led change in the planning process. © 2010 Blackwell Publishing.

  20. Photography in Dermatologic Surgery: Selection of an Appropriate Lighting Solution for a Particular Clinical Application.

    PubMed

    Chen, Brian R; Poon, Emily; Alam, Murad

    2018-01-01

    Lighting is an important component of consistent, high-quality dermatologic photography. There are different types of lighting solutions available. To evaluate currently available lighting equipment and methods suitable for procedural dermatology. Overhead lighting, built-in camera flashes, external flash units, studio strobes, and light-emitting diode (LED) light panels were evaluated with regard to their utility for dermatologic surgeons. A set of ideal lighting characteristics was used to examine the capabilities and limitations of each type of lighting solution. Recommendations regarding lighting solutions and optimal usage configurations were made in terms of the context of the clinical environment and the purpose of the image. Overhead lighting may be a convenient option for general documentation. An on-camera lighting solution using a built-in camera flash or a camera-mounted external flash unit provides portability and consistent lighting with minimal training. An off-camera lighting solution with studio strobes, external flash units, or LED light panels provides versatility and even lighting with minimal shadows and glare. The selection of an optimal lighting solution is contingent on practical considerations and the purpose of the image.

  1. Designing a critical care nurse-led rapid response team using only available resources: 6 years later.

    PubMed

    Mitchell, Anne; Schatz, Marilyn; Francis, Heather

    2014-06-01

    Rapid response teams have been introduced to intervene in the care of patients whose condition deteriorates unexpectedly by bringing clinical experts quickly to the patient's bedside. Evidence supporting the need to overcome failure to deliver optimal care in hospitals is robust; whether rapid response teams demonstrate benefit by improving patient safety and reducing the occurrence of adverse events remains controversial. Despite inconsistent evidence regarding the effectiveness of rapid response teams, concerns regarding care and costly consequences of unaddressed deterioration in patients' condition have prompted many hospitals to implement rapid response teams as a patient safety strategy. A cost-neutral structure for a rapid response team led by a nurse from the intensive care unit was implemented with the goal of reducing cardiopulmonary arrests occurring outside the intensive care unit. The results of 6 years' experience indicate that a sustainable and effective rapid response team response can be put into practice without increasing costs or adding positions and can decrease the percentage of cardiopulmonary arrests occurring outside the intensive care unit. ©2014 American Association of Critical-Care Nurses.

  2. Selective-area nanoheteroepitaxy for light emitting diode (LED) applications

    NASA Astrophysics Data System (ADS)

    Wildeson, Isaac H.

    Over 20% of the electricity in the United States is consumed for lighting, and the majority of this energy is wasted as heat during the lighting process. A solid-state (or light emitting diode (LED)-based) light source has the potential of saving the United States billions of dollars in electricity and reducing megatons of global CO2 emissions annually. While white light LEDs are currently on the market with efficiencies that are superior to incandescent and fluorescent light sources, their high up-front cost is inhibiting mass adoption. One reason for the high cost is the inefficiency of green and amber LEDs that can used to make white light. The inefficiency of green and amber LEDs results in more of these chips being required, and thus a higher cost. Improvements in the performance of green and amber LEDs is also required in order to realize the full potential of solid-state lighting. Nanoheteroepitaxy is an interesting route towards achieving efficient green and amber LEDs as it resolves major challenges that are currently plaguing III-nitride LEDs such as high dislocation densities and limited active region critical thicknesses. A method for fabricating III-nitride nanopyramid LEDs is presented that employs conventional processing used in industry. The present document begins with an overview of the current challenges in III-nitride LEDs and the benefits of nanoheteroepitaxy. A process for controlled selective-area growth of nanopyramid LEDs by organometallic vapor phase epitaxy has been developed throughout the course of this work. Dielectric templates used for the selective-area growth are patterned by two methods, namely porous anodic alumina and electron-beam lithography. The dielectric templates serve as efficient dislocation filters; however, planar defects are initiated during lower temperature growth on the nanopyramids. The quantum wells outline six semipolar planes that form each hexagonal pyramid. Quantum wells grown on these semipolar planes generate built-in electric fields with magnitudes that are one-tenth those on the polar c-plane with the same (In,Ga)N composition. The lateral strain relaxation innate in the nanoheterostructures allows greater coherent InN incorporation in the nanopyramids as compared to thin-film heterostructures, as confirmed by electroluminescence and transmission electron microscopy. In addition to applications for light emitting diodes, selective area growth of GaN nanostructures is also important for biological and sensing applications. A process for fabricating porous GaN nanorods is presented that also relies on selective-area organometallic vapor phase epitaxy. The nanopore walls are primarily outlined by nonpolar planes, and the diameter of the nanopore can be controlled by the diameter of the opening in the dielectric template and the growth time. The lining of the nanopore walls is comprised of crystalline GaN, which makes these structures interesting for sensing, electrical and optical applications.

  3. A 1024-channel 6 mW/mm2 optical stimulator for in-vitro neuroscience experiments.

    PubMed

    Cai, Lei; Wang, Baitong; Huang, Xiuxiang; Yang, Zhi

    2014-01-01

    Recent optical stimulation technologies allow improved selectivity and have been widely used in neuroscience research. This paper presents an optical stimulator based on high power LEDs. It has 1024 channels and can produce flexible stimulation patterns in each frame, refreshed at above 20 Hz. To increase the light intensity, each LED has an optical package that directs the light into a small angle. To ensure the light of each LED can reach the lens, the LEDs have been specially placed and oriented to the lens. With these efforts, the achieved power efficiency (defined as the mount of LED light power passing through the lens divided by the LED total power consumption) is 5 × 10(-5). In our current prototype, an individual LED unit can source 60 mW electrical power, where the induced irradiance on neural tissues is 6 mW/mm(2) integrating from 460 nm to 480 nm. The light spot is tunable in size from 18 μm to 40 μm with an extra 5-10 μm separation for isolating two adjacent spots. Through both bench-top measurement and finite element simulation, we found the cross channel interference is below 10%. A customized software interface has been developed to control and program the stimulator operation.

  4. Ozone Layer Research and Technical Resources

    EPA Pesticide Factsheets

    Access information on research and technical resources related to ozone layer science. This page provides links to research efforts led by organizations such as the National Oceanic and Atmospheric Administration, the United Nations Environment Program, an

  5. Oligosaccharide Mimetics

    NASA Astrophysics Data System (ADS)

    Wessel, Hans Peter; Lucas, Susana Dias

    The important roles of oligosaccharides in physiological and pathophysiological processes have spurred the development of mimetics. Oligosaccharide mimetics discussed in this chapter may possess a linker of two or more atoms such as amide or urea groups that may lead to isosteric linkage replacements but mostly do not. Larger groups that replace a full sugar unit we refer to as spacers and have grouped molecules with flexible acyclic spacers and more rigid cyclic spacers . The employment of pharmacophore models has led to oligosaccharide mimetics with only one sugar unit or finally without any saccharide unit as exemplified in mimotopes.

  6. Regulatory and scientific issues regarding use of foreign data in support of new drug applications in the United States: an FDA perspective.

    PubMed

    Khin, N A; Yang, P; Hung, H M J; Maung-U, K; Chen, Y-F; Meeker-O'Connell, A; Okwesili, P; Yasuda, S U; Ball, L K; Huang, S-M; O'Neill, R T; Temple, R

    2013-08-01

    Globalization of clinical research has led to an increase in clinical trials conducted outside of the United States that are submitted to the US Food and Drug Administration (FDA) in new drug applications. This article discusses the FDA's experience with these submissions in specific therapeutic areas, including the extent of this practice, differences between the effectiveness and safety outcomes of studies conducted inside and outside the United States, and the FDA's approach to acceptance of these trials.

  7. Potential environmental impacts of light-emitting diodes (LEDs): metallic resources, toxicity, and hazardous waste classification.

    PubMed

    Lim, Seong-Rin; Kang, Daniel; Ogunseitan, Oladele A; Schoenung, Julie M

    2011-01-01

    Light-emitting diodes (LEDs) are advertised as environmentally friendly because they are energy efficient and mercury-free. This study aimed to determine if LEDs engender other forms of environmental and human health impacts, and to characterize variation across different LEDs based on color and intensity. The objectives are as follows: (i) to use standardized leachability tests to examine whether LEDs are to be categorized as hazardous waste under existing United States federal and California state regulations; and (ii) to use material life cycle impact and hazard assessment methods to evaluate resource depletion and toxicity potentials of LEDs based on their metallic constituents. According to federal standards, LEDs are not hazardous except for low-intensity red LEDs, which leached Pb at levels exceeding regulatory limits (186 mg/L; regulatory limit: 5). However, according to California regulations, excessive levels of copper (up to 3892 mg/kg; limit: 2500), Pb (up to 8103 mg/kg; limit: 1000), nickel (up to 4797 mg/kg; limit: 2000), or silver (up to 721 mg/kg; limit: 500) render all except low-intensity yellow LEDs hazardous. The environmental burden associated with resource depletion potentials derives primarily from gold and silver, whereas the burden from toxicity potentials is associated primarily with arsenic, copper, nickel, lead, iron, and silver. Establishing benchmark levels of these substances can help manufacturers implement design for environment through informed materials substitution, can motivate recyclers and waste management teams to recognize resource value and occupational hazards, and can inform policymakers who establish waste management policies for LEDs.

  8. Influence of light-curing sources on polymerization reaction kinetics of a restorative system.

    PubMed

    D'Alpino, Paulo H P; Svizero, Nádia R; Pereira, José C; Rueggeberg, Frederick A; Carvalho, Ricardo M; Pashley, David H

    2007-02-01

    To determine the effect of using a variety of commercial light-curing units on polymerization of a dentin-bonding agent (Adper Single Bond) and of a resin composite (Filtek Z250). Infrared (IR) spectra were obtained kinetically at one scan/second at 2 cm(-1) resolution for a period of 5 minutes and were analyzed for: maximum conversion rate (%/s), time into exposure when maximum rate occurred (seconds), conversion at maximum rate (%), and total conversion (%) at 300 seconds by comparison of aliphatic-to-aromatic absorption IR peak ratios, before and after polymerization. Light units used were: QTH 540 mW/cm2 (XL3000); LED 750 mW/cm2 (Elipar FreeLight 2); PAC 2,130 mW/cm2 (ARC II). Exposure followed manufacturers' recommendations: dentin bonding agent for 10 seconds, RC for 20 seconds (QTH), and 10 seconds (LED and PAC). Polymerization kinetics was evaluated at the bottom surface (2.5 mm thick) for the resin composite and as a thin film for the dentin bonding agent on the diamond surface of an attenuated total reflectance accessory in the IR spectrometer. Values (n = 5) were compared using ANOVA and Tukey's pairwise post-hoc test: pre-set alpha 0.05. PAC produced the highest total conversion and conversion rate for the resin composite (P < 0.05). Total conversion was lower for dentin bonding adhesive using PAC than with LED or QTH (P < 0.05). LED provided the highest proportion of conversion at the maximum rate with respect to conversion at 300 seconds for both materials. QTH demonstrated the lowest maximum rate value that occurred at a longer time into exposure (P < 0.05). Polymerization kinetic parameters varied greatly between the restorative materials as well as among light-curing unit types when compared to values observed when using a QTH light as control.

  9. Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm).

    PubMed

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2017-04-01

    The aim of this in vitro study was to evaluate the effect of radiant heat on surface hardness of three conventional glass ionomer cements (GICs) by using a blue diode laser system (445 nm) and a light-emitting diode (LED) unit. Additionally, the safety of the laser treatment was evaluated. Thirty disk-shaped specimens were prepared of each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: group 1 was the control group of the study; in group 2, the specimens were irradiated for 60 s at the top surface using a LED light-curing unit; and in group 3, the specimens were irradiated for 60 s at the top surface using a blue light diode laser system (445 nm). Statistical analysis was performed using one-way ANOVA and Tukey post-hoc tests at a level of significance of a = 0.05. Radiant heat treatments, with both laser and LED devices, increased surface hardness (p < 0.05) but in different extent. Blue diode laser treatment was seemed to be more effective compared to LED treatment. There were no alterations in surface morphology or chemical composition after laser treatment. The tested radiant heat treatment with a blue diode laser may be advantageous for the longevity of GIC restorations. The safety of the use of blue diode laser for this application was confirmed.

  10. 2. GORGE HIGH DAM. UNUSUALLY HIGH WATER IN GORGE LAKE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. GORGE HIGH DAM. UNUSUALLY HIGH WATER IN GORGE LAKE DUE TO THE COMBINATION OF UNIT 24 BEING DOWN FOR REWINDING AND TWO UNITS COMING ON LINE UNEXPECTEDLY AT ROSS POWERHOUSE LED TO WATER FLOWING OVER THE SPILLGATES. EACH GATE IF 47 FEET WIDE AND 50 FEET HIGH, 1989. - Skagit Power Development, Gorge High Dam, On Skagit River, 2.9 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  11. The Mexico-United States Border: Public Policy and Chicano Economic Welfare. Studies in Human Resources Development No. 2.

    ERIC Educational Resources Information Center

    Briggs, Vernon M., Jr.

    In 1970, the gross national product for the United States was over $974 billion; for Mexico, it was $33 billion. The U.S. per capita national income was approximately $4,300, while Mexico's was slightly above $500. Living as neighbors with the reality of these vast differences has led to the implementation of various policy measures by both…

  12. Phoenix's Wet Chemistry Laboratory Units

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This image shows four Wet Chemistry Laboratory units, part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on board NASA's Phoenix Mars Lander. This image was taken before Phoenix's launch on August 4, 2007.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  13. Reflective Optics Design for an LED High Beam Headlamp of Motorbikes

    PubMed Central

    Ge, Peng; Wang, Xiang; Li, Yang; Wang, Hong

    2015-01-01

    We propose a reflective optics design for an LED motorbike high beam lamp. We set the measuring screen as an elliptical zone and divide it into many small lattices and divide the spatial angle of the LED source into many parts and make relationships between them. According to the conservation law of energy and the Snell's law, the reflector is generated by freeform optics design method. Then the optical system is simulated by Monte Carlo method using ASAP software. Light pattern of simulation could meet the standard. The high beam headlamp is finally fabricated and assembled into a physical object. Experiment results can fully comply with United Nations Economic Commission for Europe (ECE) vehicle regulations R113 revision 2 (Class C). PMID:25961073

  14. Reflective optics design for an LED high beam headlamp of motorbikes.

    PubMed

    Ge, Peng; Wang, Xiang; Li, Yang; Wang, Hong

    2015-01-01

    We propose a reflective optics design for an LED motorbike high beam lamp. We set the measuring screen as an elliptical zone and divide it into many small lattices and divide the spatial angle of the LED source into many parts and make relationships between them. According to the conservation law of energy and the Snell's law, the reflector is generated by freeform optics design method. Then the optical system is simulated by Monte Carlo method using ASAP software. Light pattern of simulation could meet the standard. The high beam headlamp is finally fabricated and assembled into a physical object. Experiment results can fully comply with United Nations Economic Commission for Europe (ECE) vehicle regulations R113 revision 2 (Class C).

  15. Comparing transfusion reaction rates for various plasma types: a systematic review and meta-analysis/regression.

    PubMed

    Saadah, Nicholas H; van Hout, Fabienne M A; Schipperus, Martin R; le Cessie, Saskia; Middelburg, Rutger A; Wiersum-Osselton, Johanna C; van der Bom, Johanna G

    2017-09-01

    We estimated rates for common plasma-associated transfusion reactions and compared reported rates for various plasma types. We performed a systematic review and meta-analysis of peer-reviewed articles that reported plasma transfusion reaction rates. Random-effects pooled rates were calculated and compared between plasma types. Meta-regression was used to compare various plasma types with regard to their reported plasma transfusion reaction rates. Forty-eight studies reported transfusion reaction rates for fresh-frozen plasma (FFP; mixed-sex and male-only), amotosalen INTERCEPT FFP, methylene blue-treated FFP, and solvent/detergent-treated pooled plasma. Random-effects pooled average rates for FFP were: allergic reactions, 92/10 5 units transfused (95% confidence interval [CI], 46-184/10 5 units transfused); febrile nonhemolytic transfusion reactions (FNHTRs), 12/10 5 units transfused (95% CI, 7-22/10 5 units transfused); transfusion-associated circulatory overload (TACO), 6/10 5 units transfused (95% CI, 1-30/10 5 units transfused); transfusion-related acute lung injury (TRALI), 1.8/10 5 units transfused (95% CI, 1.2-2.7/10 5 units transfused); and anaphylactic reactions, 0.8/10 5 units transfused (95% CI, 0-45.7/10 5 units transfused). Risk differences between plasma types were not significant for allergic reactions, TACO, or anaphylactic reactions. Methylene blue-treated FFP led to fewer FNHTRs than FFP (risk difference = -15.3 FNHTRs/10 5 units transfused; 95% CI, -24.7 to -7.1 reactions/10 5 units transfused); and male-only FFP led to fewer cases of TRALI than mixed-sex FFP (risk difference = -0.74 TRALI/10 5 units transfused; 95% CI, -2.42 to -0.42 injuries/10 5 units transfused). Meta-regression demonstrates that the rate of FNHTRs is lower for methylene blue-treated compared with FFP, and the rate of TRALI is lower for male-only than for mixed-sex FFP; whereas no significant differences are observed between plasma types for allergic reactions, TACO, or anaphylactic reactions. Reported transfusion reaction rates suffer from high heterogeneity. © 2017 AABB.

  16. 76 FR 55416 - In the Matter of Certain Led Photographic Lighting Devices and Components Thereof; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-07

    ...Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on August 3, 2011, under section 337 of the Tariff Act of 1930, as amended, 19 U.S.C. 1337, on behalf of Litepanels, Ltd. of the United Kingdom and Litepanels, Inc. of Van Nuys, California. Supplements to the Complaint were filed on August 24, and August 25, 2011. The complaint alleges violations of section 337 based upon the importation into the United States, the sale for importation, and the sale within the United States after importation of certain LED photographic lighting devices and components thereof by reason of infringement of certain claims of U.S. Patent No. 7,972,022 (``the `022 patent''); U.S. Patent No. 7,510,290 (``the `290 patent''); U.S. Patent No. 7,429,117 (``the `117 patent''); U.S. Patent No. 7,318,652 (``the `652 patent''); and U.S. Patent No. 6,948,823 (``the `823 patent''). The complaint further alleges that an industry in the United States exists as required by subsection (a)(2) of section 337. The complainants request that the Commission institute an investigation and, after the investigation, issue an exclusion order and cease and desist orders.

  17. Designing low cost LED display for the billboard

    NASA Astrophysics Data System (ADS)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  18. Transmembrane helix M6 in sarco(endo)plasmic reticulum Ca(2+)-ATPase forms a functional interaction site with phospholamban. Evidence for physical interactions at other sites.

    PubMed

    Asahi, M; Kimura, Y; Kurzydlowski, K; Tada, M; MacLennan, D H

    1999-11-12

    In an earlier study (Kimura, Y., Kurzydlowski, K., Tada, M., and MacLennan, D. H. (1997) J. Biol. Chem. 272, 15061-15064), mutation of amino acids on one face of the phospholamban (PLN) transmembrane helix led to loss of PLN inhibition of sarco(endo)plasmic reticulum Ca(2+)-ATPase (SERCA) molecules. This helical face was proposed to form a site of PLN interaction with a transmembrane helix in SERCA molecules. To determine whether predicted transmembrane helices M4, M5, M6, or M8 in SERCA1a interact with PLN, SERCA1a mutants were co-expressed with wild-type PLN and effects on Ca(2+) dependence of Ca(2+) transport were measured. Wild-type inhibitory interactions shifted apparent Ca(2+) affinity of SERCA1a by an average of -0.34 pCa units, but four of the seven mutations in M4 led to a more inhibitory shift in apparent Ca(2+) affinity, averaging -0.53 pCa units. Seven mutations in M5 led to an average shift of -0.32 pCa units and seven mutations in M8 led to an average shift of -0.30 pCa units. Among 11 mutations in M6, 1, Q791A, increased the inhibitory shift (-0.59 pCa units) and 5, V795A (-0.11), L802A (-0.07), L802V (-0.04), T805A (-0.11), and F809A (-0.12), reduced the inhibitory shift, consistent with the view that Val(795), Leu(802), Thr(805), and Phe(809), located on one face of a predicted M6 helix, form a site in SERCA1a for interaction with PLN. Those mutations in M4, M6, or M8 of SERCA1a that enhanced PLN inhibitory function did not enhance PLN physical association with SERCA1a, but mutants V795A and L802A in M6, which decreased PLN inhibitory function, decreased physical association, as measured by co-immunoprecipitation. In related studies, those PLN mutants that gained inhibitory function also increased levels of co-immunoprecipitation of wild-type SERCA1a and those that lost inhibitory function also reduced association, correlating functional interaction sites with physical interaction sites. Thus, both functional and physical data confirm that PLN interacts with M6 SERCA1a.

  19. Evaluation of light intensity output of QTH and LED curing devices in various governmental health institutions.

    PubMed

    Al Shaafi, Mm; Maawadh, Am; Al Qahtani, Mq

    2011-01-01

    The purpose of this study was to evaluate the light intensity output of quartz-tungsten-halogen (QTH) and light emitting diode (LED) curing devices located at governmental health institutions in Riyadh, Saudi Arabia.Eight governmental institutions were involved in the study. The total number of evaluated curing devices was 210 (120 were QTH and 90 were LED). The reading of the light intensity output for each curing unit was achieved using a digital spectrometer; (Model USB4000 Spectrometer, Ocean Optics Inc, Dunedin, FL, USA). The reading procedure was performed by a single investigator; any recording of light intensity below 300 mW/cm2 was considered unsatisfactory.The result found that the recorded mean values of light intensity output for QTH and LED devices were 260 mW/cm2 and 598 mW/cm2, respectively. The percentage of QTH devices and LED devices considered unsatisfactory was 67.5% and 15.6%, respectively. Overall, the regular assessment of light curing devices using light meters is recommended to assure adequate output for clinical use.

  20. ACHP | News

    Science.gov Websites

    , and engineering that led to the creation of the atomic bomb, the role these weapons played in World War II, and how the role of the United States in global affairs has evolved in the nuclear age. The

  1. Optical Indoor Positioning System Based on TFT Technology.

    PubMed

    Gőzse, István

    2015-12-24

    A novel indoor positioning system is presented in the paper. Similarly to the camera-based solutions, it is based on visual detection, but it conceptually differs from the classical approaches. First, the objects are marked by LEDs, and second, a special sensing unit is applied, instead of a camera, to track the motion of the markers. This sensing unit realizes a modified pinhole camera model, where the light-sensing area is fixed and consists of a small number of sensing elements (photodiodes), and it is the hole that can be moved. The markers are tracked by controlling the motion of the hole, such that the light of the LEDs always hits the photodiodes. The proposed concept has several advantages: Apart from its low computational demands, it is insensitive to the disturbing ambient light. Moreover, as every component of the system can be realized by simple and inexpensive elements, the overall cost of the system can be kept low.

  2. Spreading a medication administration intervention organizationwide in six hospitals.

    PubMed

    Kliger, Julie; Singer, Sara; Hoffman, Frank; O'Neil, Edward

    2012-02-01

    Six hospitals from the San Francisco Bay Area participated in a 12-month quality improvement project conducted by the Integrated Nurse Leadership Program (INLP). A quality improvement intervention that focused on improving medication administration accuracy was spread from two pilot units to all inpatient units in the hospitals. INLP developed a 12-month curriculum, presented in a combination of off-site training sessions and hospital-based training and consultant-led meetings, to teach clinicians the key skills needed to drive organizationwide change. Each hospital established a nurse-led project team, as well as unit teams to address six safety processes designed to improve medication administration accuracy: compare medication to the medication administration record; keep medication labeled throughout; check two patient identifications; explain drug to patient (if applicable); chart immediately after administration; and protect process from distractions and interruptions. From baseline until one year after project completion, the six hospitals improved their medication accuracy rates, on average, from 83.4% to 98.0% in the spread units. The spread units also improved safety processes overall from 83.1% to 97.2%. During the same time, the initial pilot units also continued to improve accuracy from 94.0% to 96.8% and safety processes overall from 95.3% to 97.2%. With thoughtful planning, engaging those doing the work early and focusing on the "human side of change" along with technical knowledge of improvement methodologies, organizations can spread initiatives enterprisewide. This program required significant training of frontline workers in problem-solving skills, leading change, team management, data tracking, and communication.

  3. International comparative analyses of healthcare risk management.

    PubMed

    Sun, Niuyun; Wang, Li; Zhou, Jun; Yuan, Qiang; Zhang, Zongjiu; Li, Youping; Liang, Minghui; Cheng, Lan; Gao, Guangming; Cui, Xiaohui

    2011-02-01

    Interpretation of the growing body of global literature on health care risk is compromised by a lack of common understanding and language. This series of articles aims to comprehensively compare laws and regulations, institutional management, and administration of incidence reporting systems on medical risk management in the United Kingdom, the United States, Canada, Australia, and Taiwan, so as to provide evidence and recommendations for health care risk management policy in China. We searched the official websites of the healthcare risk management agencies of the four countries and one district for laws, regulatory documents, research reports, reviews and evaluation forms concerned with healthcare risk management and assessment. Descriptive comparative analysis was performed on relevant documents. A total of 146 documents were included in this study, including 2 laws (1.4%), 17 policy documents (11.6%), 41 guidance documents (28.1%), 37 reviews (25.3%), and 49 documents giving general information (33.6%). The United States government implemented one law and one rule of patient safety management, while the United Kingdom and Australia each issued professional guidances on patient safety improvement. The four countries implemented patient safety management policy on four different levels: national, state/province, hospital, and non-governmental organization. The four countries and one district adopted four levels of patient safety management, and the administration modes can be divided into an "NGO-led mode" represented by the United States and Canada and a "government-led mode" represented by the United Kingdom, Australia, and Taiwan. © 2011 Blackwell Publishing Asia Pty Ltd and Chinese Cochrane Center, West China Hospital of Sichuan University.

  4. Child-led enquiry in primary science

    PubMed Central

    Dunlop, Lynda; Compton, Kirsty; Clarke, Linda; McKelvey-Martin, Valerie

    2015-01-01

    This research describes and evaluates the application of a child-led approach to scientific enquiry (the Community of Scientific Enquiry, CoSE) to children aged 8–11 (Key Stage 2) in Northern Ireland. Primary teachers were introduced to CoSE at a workshop and asked to evaluate its implementation with their class. Results from children (n = 364) and teachers (n = 19) found that CoSE engaged children with their science learning, and also developed confidence and oracy. However, teachers require more experience developing facilitation skills and in fitting science into a thematic teaching unit. PMID:27152060

  5. A comparative evaluation of effect of modern-curing lights and curing modes on conventional and novel-resin monomers

    PubMed Central

    Roy, Konda Karthik; Kumar, Kanumuru Pavan; John, Gijo; Sooraparaju, Sujatha Gopal; Nujella, Surya Kumari; Sowmya, Kyatham

    2018-01-01

    Aim: The aim of this study is to compare and to evaluate effect of curing light and curing modes on the nanohybrid composite resins with conventional Bis-GMA and novel tricyclodecane (TCD) monomers. Methodology: Two nanohybrid composites, IPS empress direct and charisma diamond were used in this study. Light-emitting diode (LED)-curing unit and quartz-tungsten-halogen (QTH)-curing unit which were operated into two different modes: continuous and soft start. Based on the composite resin, curing lights, and mode of curing used, the samples were divided into 8 groups. After polymerization, the samples were stored for 48 h in complete darkness at 37°C and 100% humidity. The Vickers hardness (VK) of the surface was determined with Vickers indenter by the application of 200 g for 15 s. Three VK readings were recorded for each sample surface both on top and bottom surfaces. For all the specimens, the three hardness values for each surface were averaged and reported as a single value. The mean VK and hardness ratio were calculated. The depth of cure was assessed based on the hardness ratio. Results: Comparison of mean hardness values and hardness ratios was done using ANOVA with post hoc Tukey's test. Conclusion: Both QTH- and LED-curing units had shown the adequate depth of cure. Soft-start-curing mode in both QTH- and LED-curing lights had effectively increased microhardness than the continuous mode of curing. TCD monomer had shown higher hardness values compared with conventional Bis-GMA-containing resin. PMID:29628651

  6. What the QDR Ought to Say about Landpower

    DTIC Science & Technology

    2013-01-01

    debates center on the missions, costs, or effectiveness, one should be wary of those critics pro- moting a new “Vietnam syndrome ,” arguing the United...States should never again go down the path it did over the last decade.6 Playing to this syndrome led directly to the problems encountered before...an even greater burden for the United States in allied and partner operations. 22 Frank G. Hoffman and Mike Noonan , “Defense Reorganization

  7. Portrait of Waldo Smith

    NASA Astrophysics Data System (ADS)

    Spilhaus, Fred

    2009-01-01

    In 1944, Waldo Smith was looking for a place where he could make a difference. He had taught in universities in the United States and Turkey, and he had worked as an engineer in the field of hydrology in the United States. Somehow, a chance meeting with John Adam Fleming, AGU's long-time General Secretary, led to Waldo's becoming the first executive officer employed by the Union. That, in turn, brought him the opportunity to make a difference.

  8. Protecting the Civil Rights of English Language Learners Today: A Study of the Recent DOJ and OCR Investigations of Selected School Districts in the United States

    ERIC Educational Resources Information Center

    Oyeleye, Omobola Awosika

    2013-01-01

    The purpose of the study was to examine the circumstances and practices that led to OCR and DOJ investigations in seven selected school districts, and to determine the emerging themes from the details of the settlement agreements between the school districts and the United States. The themes developed through this study were aimed at providing a…

  9. "The Same Tragic History of the Oppressed Must Not Be Repeated": Exploring the Unique Approach to Social Justice of Dr. Mitsunori Misawa

    ERIC Educational Resources Information Center

    Nakabayashi, Hayato

    2016-01-01

    Originally from Japan, Dr. Mitsunori Misawa is a professor of the Higher and Adult Education program in the Department of Leadership at the College of Education, Health and Human Sciences, at the University of Memphis in the United States. This paper introduces what led Dr. Misawa to study and work in the United States, how he came to pursue an…

  10. Franchise. Quantum leap.

    PubMed

    Mooney, Helen

    2008-05-15

    The Royal Marsden's chemotherapy unit in Kingston will not only treat its own patients who live locally, but also accept referrals from local GPs. The move is part of a trend by well-known hospitals to open franchises, led by the Moorfields Eye Hospital which has 11 satellite units, including one in Dubai. Franchising by specialist hospitals can increase services, raise income and expand their brand. It also allows specialist staff to work in a range of settings.

  11. United Nations-Led Disarmament, Demobilization and Reintegration (DDR) in the Eastern Democratic Republic of Congo

    DTIC Science & Technology

    2011-12-01

    absorb rebel units into the national army failed to deconstruct previous personal and ideological allegiances to the former rebel movement and thus...victors our outside interveners, such as India in Sri Lanka, the U.S. in Somalia and Haiti, and UN interventions in Albania and Haiti.30 Nevertheless...Reconstructing Masculinities : The Disarmament, Demobilization, and Reintegration of Former Combatants in Colombia.” Human Rights Quarterly, Vol.31

  12. Photodynamic antimicrobial chemotherapy on Streptococcus mutans using curcumin and toluidine blue activated by a novel LED device.

    PubMed

    Paschoal, Marco Aurelio; Lin, Meng; Santos-Pinto, Lourdes; Duarte, Simone

    2015-02-01

    Photodynamic antimicrobial chemotherapy (PACT) is an antimicrobial approach that uses photosensitizers (PS) in combination with light sources at specific wavelengths aiming the production of reactive oxygen species. The long illumination time necessary to active PS is a challenge in PACT. Thus, this study investigated the antimicrobial effect of a novel single source of light-emitting diode (LED) light that covers the entire spectrum of visible light beyond interchangeable probes at high power intensity. Blue and red LED probes were used into different exposure times to active different concentrations of curcumin (C) and toluidine blue (T) on planktonic suspensions of Streptococcus mutans UA 159 (S. mutans). S. mutans were standardized and submitted to (1) PACT treatment at three concentrations of C and T exposure at three radiant exposures of a blue LED (BL) (C+BL+) and a red LED (RL) (T+RL+), (2) C (C+BL-) or T alone (T+RL-), (3) both LED lights (C-BL+ and T-RL+), and (4) neither PS nor LED illumination (control group: C-BL- and T-RL-). Aliquots of the suspensions were diluted and cultured on blood agar plates. The number of colony-forming units was calculated after 48 h. The groups submitted to PACT presented a lethal photokilling rate to all PS concentrations at tested dosimetries. The comparison to control group when PS and LED lights used alone demonstrated no decrease in the number of viable bacterial counts. The novel LED device in combination with curcumin and toluidine blue promoted an effective photoinactivation of S. mutans suspensions at ultrashort light illumination times.

  13. Review of national railroad issues

    DOT National Transportation Integrated Search

    1975-12-01

    In 1973, the financial disarray of the Northeast and mid-West railroads led to : the passage of the Rail Reorganization Act of 1973. The Act established the : United States Railway Association (USRA) to develop a plan for a Consolidated : Rail Corpor...

  14. ANALYSIS OF GEOTHERMAL WASTES FOR HAZARDOUS COMPONENTS

    EPA Science Inventory

    Regulations governing the disposal of hazardous wastes led to an assessment for geothermal solid wastes for potentially hazardous properties. Samples were collected from three active geothermal sites in the western United States: The Geysers, Imperial Valley, and northwestern Nev...

  15. Investigation of structure in the modular light pipe component for LED automotive lamp

    NASA Astrophysics Data System (ADS)

    Chen, Hsi-Chao; Zhou, Yang; Huang, Chien-Sheng; Jhong, Wan-Ling; Cheng, Bo-Wei; Jhang, Jhe-Ming

    2014-09-01

    Light-Emitting Diodes (LEDs) have the advantages of small length, long lifetime, fast response time (μs), low voltage, good mechanical properties and environmental protection. Furthermore, LEDs could replace the halogen lamps to avoid the mercury pollution and economize the use of energy. Therefore, the LEDs could instead of the traditional lamp in the future and became an important light source. The proposal of this study was to investigate the effects of the structure and length of the reflector component for a LED automotive lamp. The novel LED automotive lamp was assembled by several different modularization columnar. The optimized design of the different structure and the length to the reflector was simulated by software TracePro. The design result must met the vehicle regulation of United Nations Economic Commission for Europe (UNECE) such as ECE-R19 etc. The structure of the light pipe could be designed by two steps structure. Then constitute the proper structure and choose different power LED to meet the luminous intensity of the vehicle regulation. The simulation result shows the proper structure and length has the best total luminous flux and a high luminous efficiency for the system. Also, the stray light could meet the vehicle regulation of ECE R19. Finally, the experimental result of the selected structure and length of the light pipe could match the simulation result above 80%.

  16. Licensed pertussis vaccines in the United States. History and current state.

    PubMed

    Klein, Nicola P

    2014-01-01

    The United States switched from whole cell to acellular pertussis vaccines in the 1990s following global concerns with the safety of the whole cell vaccines. Despite high levels of acellular pertussis vaccine coverage, the United States and other countries are experiencing large pertussis outbreaks. The aim of this article is to describe the historical context which led to acellular pertussis vaccine development, focusing on vaccines currently licensed in the US, and to review evidence that waning protection following licensed acellular pertussis vaccines have been significant factors in the widespread reappearance of pertussis.

  17. Xeroderma pigmentosum in the United kingdom.

    PubMed

    Lehmann, Alan R

    2015-01-01

    The seminal discovery by James Cleaver of defective DNA repair in xeroderma pigmentosum (XP) opened up an ever-expanding field of DNA repair-related disorders. In addition, it put XP on the map and has led to improved diagnosis, care and management of affected patients. In the United Kingdom, we recently established a multidisciplinary specialist clinic for XP patients. All XP patients in the United Kingdom are able to visit the clinic where they are examined and advised by a team of specialists with detailed knowledge of the different aspects of XP. © 2014 The American Society of Photobiology.

  18. Development of a cardiac technician led paediatric echocardiographic service--experience from a district general hospital in the United Kingdom.

    PubMed

    Allen, Jane; Dickinson, David F; Ramachandran, Arun; Thomson, John D R

    2005-06-01

    To report our experience in providing cardiac technician led paediatric echocardiography services in a district general hospital in the United Kingdom. We have collected prospectively the numbers of referrals, and the proportion of abnormal echocardiograms, since inception of the service in 2000. In additional, for a period of 12 months, we have audited in detail the patterns of referral to the service, and outcomes, assessing the effect of the service on the outreach clinic run by a visiting paediatric cardiologist. Use of the system resulted in detection of a wide range of abnormalities, with our audit showing that the patients received appropriate management. The total referrals to the service increased 10 fold over the 4 year period of the study. The proportion of abnormal hearts detected by echocardiography, however, dropped from 90 per cent to 16 per cent over the same period. The numbers of patients seen in the outreach cardiology clinic remained unaltered. Having been proved to be an effective model for the triage of children with suspected congenital cardiac disease, adoption of a cardiac technician led echocardiographic service has seen a dramatic increase in the numbers of echocardiograms requested, without decreasing the workload of the visiting paediatric cardiologist.

  19. Polymerization of a dual-cured cement through ceramic: LED curing light vs halogen lamp.

    PubMed

    Lopes, Lawrence Gonzaga; Franco, Eduardo Batista; Name Neto, Abrão; Herrera, Francyle S; Kurachi, Cristina; Castañeda-Espinosa, Juan C; Lauris, José Roberto Pereira

    2004-12-01

    The aim of this study was to investigate the influence of light source, LED unit and halogen lamp (HL), on the effectiveness of Enforce dual-cured cement cured under a ceramic disc. Three exposure times (60, 80 and 120 s) were also evaluated. Two experimental groups, in which the polymerization of the dual-cured cement was performed through a ceramic disc, and two control groups, in which the polymerization of the dual-cured cement was performed directly without presence of ceramic disc were subdivided into three subgroups (three different exposure times), with five specimens each: G1A- HL 60s; G1B- HL 80s; G1C- HL 120s; G2A- LED 60s; G2B- LED 80s; G2C- LED 120s; and control groups: G3A- HL 60s; G3B- HL 80s; G3C- HL 120s; G4A- LED 60s; G4B- LED 80s and G4C- LED 120s. Cement was applied in a steel matrix (4mm diameter, 1.2mm thickness). In the experimental groups, a ceramic disc was placed on top. The cement was light-cured through the ceramic by a HL and LED, however, the control groups were cured without the ceramic disc. The specimens were stored in a light-proof container at 37ºC for 24 hours, then Vickers hardness was determined. A four-way ANOVA and Tukey test (p£ 0.05) were performed. All specimens cured by LED for 60s showed inferior values compared with the halogen groups. In general, light-curing by LED for 80s and 120s was comparable to halogen groups (60s and 80s) and their control groups. LED technology can be viable for light-curing through conventional ceramic indirect restorations, when curing time is increased in relation to HL curing time.

  20. In vitro pulp chamber temperature rise from irradiation and exotherm of flowable composites.

    PubMed

    Baroudi, Kusai; Silikas, Nick; Watts, David C

    2009-01-01

    The aim of this study was to investigate the pulpal temperature rise induced during the polymerization of flowable and non-flowable composites using light-emitting diode (LED) and halogen (quartz-tungsten-halogen) light-curing units (LCUs). Five flowable and three non-flowable composites were examined. Pulpal temperature changes were recorded over 10 min in a sample primary tooth by a thermocouple. A conventional quartz-tungsten-halogen source and two LEDs, one of which was programmable, were used for light curing the resin composites. Three repetitions per material were made for each LCU. There was a wide range of temperature rises among the materials (P < 0.05). Temperature rises ranged between 1.3 degrees C for Filtek Supreme irradiated by low-power LED and 4.5 degrees C for Grandio Flow irradiated by high-power LED. The highest temperature rises were observed with both the LED high-power and soft-start LCUs. The time to reach the exothermic peak varied significantly between the materials (P < 0.05). Pulpal temperature rise is related to both the radiant energy output from LCUs and the polymerization exotherm of resin composites. A greater potential risk for heat-induced pulp damage might be associated with high-power LED sources. Flowable composites exhibited higher temperature rises than non-flowable materials, because of higher resin contents.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wierer, Jonathan J.; Tsao, Jeffrey Y.; Sizov, Dmitry S.

    Solid-state lighting (SSL) is now the most efficient source of high color quality white light ever created. Nevertheless, the blue InGaN light-emitting diodes (LEDs) that are the light engine of SSL still have significant performance limitations. Foremost among these is the decrease in efficiency at high input current densities widely known as “efficiency droop.” Efficiency droop limits input power densities, contrary to the desire to produce more photons per unit LED chip area and to make SSL more affordable. Pending a solution to efficiency droop, an alternative device could be a blue laser diode (LD). LDs, operated in stimulated emission,more » can have high efficiencies at much higher input power densities than LEDs can. In this article, LEDs and LDs for future SSL are explored by comparing: their current state-of-the-art input-power-density-dependent power-conversion efficiencies; potential improvements both in their peak power-conversion efficiencies and in the input power densities at which those efficiencies peak; and their economics for practical SSL.« less

  2. Evaluation of a peer-led drug abuse risk reduction project for runaway/homeless youths.

    PubMed

    Fors, S W; Jarvis, S

    1995-01-01

    The purpose of this study was to evaluate the Drug Prevention in Youth risk reduction program that was implemented in shelters for runaway/homeless youths in the Southeastern United States. The program focuses on knowledge, attitudes and skills that can help this group of high risk young people minimize the serious negative consequences of drug abuse. An evaluation strategy was developed so comparisons could be made between peer-led, adult-led and non-intervention groups. Dependent samples t tests and least squares ANCOVAS were used to measure pretest-posttest differences both within and between groups. Results indicate that the peer-led groups were more successful than the other two groups, and that program effects were the most powerful with the youngest group of shelter clients. Process evaluation revealed important factors related to group leader training and group management. It is concluded that well-trained and motivated peer/near peer leaders have particularly valuable contributions to make with regard to drug abuse risk reduction for shelter clients.

  3. Impact of improving vehicle front design on the burden of pedestrian injuries in Germany, the United States, and India.

    PubMed

    Moran, Dane; Bose, Dipan; Bhalla, Kavi

    2017-11-17

    European car design regulations and New Car Assessment Program (NCAP) ratings have led to reductions in pedestrian injuries. The aim of this study was to evaluate the impact of improving vehicle front design on mortality and morbidity due to pedestrian injuries in a European country (Germany) and 2 countries (the United States and India) that do not have pedestrian-focused NCAP testing or design regulations. We used data from the International Road Traffic and Accident Database and the Global Burden of Disease project to estimate baseline pedestrian deaths and nonfatal injuries in each country in 2013. The effect of improved passenger car star ratings on probability of pedestrian injury was based on recent evaluations of pedestrian crash data from Germany. The effect of improved heavy motor vehicle (HMV) front end design on pedestrian injuries was based on estimates reported by simulation studies. We used burden of disease methods to estimate population health loss by combining the burden of morbidity and mortality in disability-adjusted life years (DALYs) lost. Extrapolating from evaluations in Germany suggests that improving front end design of cars can potentially reduce the burden of pedestrian injuries due to cars by up to 24% in the United States and 41% in India. In Germany, where cars comply with the United Nations regulation on pedestrian safety, additional improvements would have led to a 1% reduction. Similarly, improved HMV design would reduce DALYs lost by pedestrian victims hit by HMVs by 20% in each country. Overall, improved vehicle design would reduce DALYs lost to road traffic injuries (RTIs) by 0.8% in Germany, 4.1% in the United States, and 6.7% in India. Recent evaluations show a strong correlation between Euro NCAP pedestrian scores and real-life pedestrian injuries, suggesting that improved car front end design in Europe has led to substantial reductions in pedestrian injuries. Although the United States has fewer pedestrian crashes, it would nevertheless benefit substantially by adopting similar regulations and instituting pedestrian NCAP testing. The maximum benefit would be realized in low- and middle-income countries like India that have a high proportion of pedestrian crashes. Though crash avoidance technologies are being developed to protect pedestrians, supplemental protection through design regulations may significantly improve injury countermeasures for vulnerable road users.

  4. Protection of Hawaii's Observatories from Light Pollution

    NASA Astrophysics Data System (ADS)

    Wainscoat, Richard J.

    2018-01-01

    Maunakea Observatory, located on the island of Hawaii, is among the world darkest sites for astronomy. Strong efforts to preserve the dark night sky over the last forty years have proven successful. Artificial light presently adds only approximately 2% to the natural night sky brightness. The techniques being used to protect Maunakea from light pollution will be described, along with the challenges that are now being faced.Haleakala Observatory, located on the island of Maui, is also an excellent observing site, and is among the best sites in the United States. Lighting restrictions in Maui County are much weaker, and consequently, the night sky above Haleakala is less well protected. Haleakala is closer to Honolulu and the island of Oahu (population approximately 1 million), and the glow from Oahu makes the northwestern sky brighter.Much of the lighting across most of the United States, including Hawaii, is presently being converted to LED lighting. This provides an opportunity to replace existing poorly shielded lights with properly shielded LED fixtures, but careful spectral management is essential. It is critically important to only use LED lighting that is deficient in blue and green light. LED lighting also is easy to dim. Dimming of lights later at night, when there is no need for brighter lighting, is an important tool for reducing light pollution.Techniques used to protect astronomical observatories from light pollution are similar to the techniques that must be used to protect animals that are affected by light at night, such as endangered birds and turtles. These same techniques are compatible with recent human health related lighting recommendations from the American Medical Association.

  5. Characterizing the output settings of dental curing lights.

    PubMed

    Harlow, J E; Sullivan, B; Shortall, A C; Labrie, D; Price, R B

    2016-01-01

    For improved inter-study reproducibility and ultimately improved patient care, researchers and dentists need to know what electromagnetic radiation (light) is emitted from the light-curing unit (LCU) they are using and what is received by the resin. This information cannot be obtained from a dental radiometer, even though many studies have used a dental radiometer. The light outputs from six LCUs (two QTH and four broad-spectrum LED units) were collected in real-time using an integrating sphere connected to a fiberoptic spectrometer during different light exposures. It was found that the spectral emissions were unique to each LCU, and there was no standardization in what was emitted on the various ramp (soft-start) settings. Relative to the normal use setting, using the ramp setting reduced the radiant energy (J) delivered from each LCU. For one of the four broad-spectrum LED LCUs, the spectral emissions in the violet range did not increase when the overall radiant power output was increased. In addition, this broad-spectrum LED LCU emitted no light from the violet LED chip for the first 5s and only emitted violet light when the ramp phase finished. A single irradiance value derived from a dental radiometer or from a laboratory grade power meter cannot adequately describe the output from the LCU. Manufacturers should provide more information about the light output from their LCUs. Ideally, future assessments and research publications that include resin photopolymerization should report the spectral radiant power delivered from the LCU throughout the entire exposure cycle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Determinants of Toxicity of Environmental Asbestos Fibers

    EPA Science Inventory

    Recent EPA-led studies have addressed the comparative toxicity and pathological mechanisms of environmental asbestos samples from Libby, Montana and other communities in the United States. Longer amosite fibers induce a 4-10 fold greater induction of pro-inflammatory mediators C...

  7. NATO/CCMS PILOT STUDY ON CLEAN PRODUCTS & PROCESSES

    EPA Science Inventory

    Led by the United States, represented by the U.S. Environmental Protection Agency's (EPA's) National Risk Management Research Laboratory, the Pilot Study on Clean Products and Processes was instituted to create an international forum where current trends, developments, and expert...

  8. Cuba: Background to a Revolution.

    ERIC Educational Resources Information Center

    De La Fuente, Alejandro

    2000-01-01

    Provides historical information on Cuba. Addresses early colonization, the advent of plantation agriculture, the role and presence of the United States in the Caribbean and Cuba, and the social and economic developments in Cuba after the revolution in 1959 led by Fidel Castro. (CMK)

  9. Western Hemisphere Defense Policy Statement

    DTIC Science & Technology

    2012-10-01

    El Salvador , Guatemala, Honduras, Paraguay, Peru and Uruguay have contributed to or led multi-national security operations and United Nations (UN...critical support during the initial stages of the Haiti earthquake relief effort. As military forces often have a unique capability to respond

  10. The J-Staff System, Network Synchronisation and Noise

    DTIC Science & Technology

    2014-06-01

    GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S... work . A key challenge of such structures is their tendency to fall into extreme dynamical modes. One is a ‘two-speed’ mode, where units interacting with...longer term planning, led by the J5 Planning Branch, fall into a slow cycle of work , while those entities interacting predominately with operations

  11. Effectiveness of United StatesLed Economic Sanctions as a Counterproliferation Tool Against Irans Nuclear Weapons Program

    DTIC Science & Technology

    2015-12-01

    www.nytimes.com/2015/07/15/world/middleeast/iran-nuclear-deal-is- reached-after-long-negotiations.html. 70 Valerie Lincy and Simon Chin, “How to...procuring steel and other materials used in the manufacturing of missile propellants. Lastly, in the United Kingdom case, the State Department...97 Valerie Lincy and Gary Milhollin, “Iran’s Nuclear Timetable,” Wisconsin Project on Nuclear Arms Control, June 17, 2015, http

  12. Can Refugees Be National Security Assets : Afghan American Contributions to U.S. National Defense since 1978

    DTIC Science & Technology

    2016-04-12

    cultural advisors for the U.S. government and military. Most Afghans came to the United States since 1978, after war broke out in Afghanistan and created...September 2001, Afghans in the United States have served as interpreters, analysts, language instructors, and cultural advisors . Others used the...negatively about the Communist-inspired, nominally Af- ghan government.16 Resentment of the Afghan government and its Soviet allies led to the desire of

  13. Automation of Vapor-Diffusion Growth of Protein Crystals

    NASA Technical Reports Server (NTRS)

    Hamrick, David T.; Bray, Terry L.

    2005-01-01

    Some improvements have been made in a system of laboratory equipment developed previously for studying the crystallization of proteins from solution by use of dynamically controlled flows of dry gas. The improvements involve mainly (1) automation of dispensing of liquids for starting experiments, (2) automatic control of drying of protein solutions during the experiments, and (3) provision for automated acquisition of video images for monitoring experiments in progress and for post-experiment analysis. The automation of dispensing of liquids was effected by adding an automated liquid-handling robot that can aspirate source solutions and dispense them in either a hanging-drop or a sitting-drop configuration, whichever is specified, in each of 48 experiment chambers. A video camera of approximately the size and shape of a lipstick dispenser was added to a mobile stage that is part of the robot, in order to enable automated acquisition of images in each experiment chamber. The experiment chambers were redesigned to enable the use of sitting drops, enable backlighting of each specimen, and facilitate automation.

  14. Defect Induced Mix Experiments (DIME) for NIF

    NASA Astrophysics Data System (ADS)

    Schmitt, Mark; Bradley, Paul; Cobble, James; Hsu, Scott; Krasheninnikova, Natalia; Magelssen, Glenn; Murphy, Thomas; Obrey, Kimberly; Tregillis, Ian; Wysocki, Frederick

    2011-10-01

    Los Alamos National Laboratory will be performing FY12 NIF experiments using polar direct drive to measure the effects of high mode number defects on ICF implosion hydrodynamics and yield. The effect of equatorial groove features will be assessed using both x-ray backlighting and spectrally resolved imaging of higher-Z dopant layers in 2.2 mm diameter (30 microns thick) CH capsules using a multiple monochromatic imager (MMI). By placing thin, 2 micron thick, layers containing ~1.5% of either Ge or Se at different depths in the capsule, we will be able to characterize the mixing and heating of these layers in both perturbed and unperturbed regions of the capsule. Precursor experiments have been performed on Omega to validate these measurement methods using Ti and V layers. An overview of our current results from Omega and design efforts for NIF will be presented. Work performed by Los Alamos National Laboratory under contract DE-AC52-06NA25396 for the National Nuclear Security Administration of the U.S. Department of Energy.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smalyuk, V. A.; Robey, H. F.; Casey, D. T.

    Several new platforms have been developed to experimentally measure hydrodynamic instabilities in all phases of indirect-drive, inertial confinement fusion implosions on National Ignition Facility. At the ablation front, instability growth of pre-imposed modulations was measured with a face-on, x-ray radiography platform in the linear regime using the Hydrodynamic Growth Radiography (HGR) platform. Modulation growth of "native roughness" modulations and engineering features (fill tubes and capsule support membranes) were measured in conditions relevant to layered DT implosions. A new experimental platform was developed to measure instability growth at the ablator-ice interface. Here in the deceleration phase of implosions, several experimental platformsmore » were developed to measure both low-mode asymmetries and high-mode perturbations near peak compression with x-ray and nuclear techniques. In one innovative technique, the self-emission from the hot spot was enhanced with argon dopant to "self-backlight" the shell in-flight. To stabilize instability growth, new "adiabat-shaping" techniques were developed using the HGR platform and applied in layered DT implosions.« less

  16. Mix and hydrodynamic instabilities on NIF

    NASA Astrophysics Data System (ADS)

    Smalyuk, V. A.; Robey, H. F.; Casey, D. T.; Clark, D. S.; Döppner, T.; Haan, S. W.; Hammel, B. A.; MacPhee, A. G.; Martinez, D.; Milovich, J. L.; Peterson, J. L.; Pickworth, L.; Pino, J. E.; Raman, K.; Tipton, R.; Weber, C. R.; Baker, K. L.; Bachmann, B.; Berzak Hopkins, L. F.; Bond, E.; Caggiano, J. A.; Callahan, D. A.; Celliers, P. M.; Cerjan, C.; Dixit, S. N.; Edwards, M. J.; Felker, S.; Field, J. E.; Fittinghoff, D. N.; Gharibyan, N.; Grim, G. P.; Hamza, A. V.; Hatarik, R.; Hohenberger, M.; Hsing, W. W.; Hurricane, O. A.; Jancaitis, K. S.; Jones, O. S.; Khan, S.; Kroll, J. J.; Lafortune, K. N.; Landen, O. L.; Ma, T.; MacGowan, B. J.; Masse, L.; Moore, A. S.; Nagel, S. R.; Nikroo, A.; Pak, A.; Patel, P. K.; Remington, B. A.; Sayre, D. B.; Spears, B. K.; Stadermann, M.; Tommasini, R.; Widmayer, C. C.; Yeamans, C. B.; Crippen, J.; Farrell, M.; Giraldez, E.; Rice, N.; Wilde, C. H.; Volegov, P. L.; Gatu Johnson, M.

    2017-06-01

    Several new platforms have been developed to experimentally measure hydrodynamic instabilities in all phases of indirect-drive, inertial confinement fusion implosions on National Ignition Facility. At the ablation front, instability growth of pre-imposed modulations was measured with a face-on, x-ray radiography platform in the linear regime using the Hydrodynamic Growth Radiography (HGR) platform. Modulation growth of "native roughness" modulations and engineering features (fill tubes and capsule support membranes) were measured in conditions relevant to layered DT implosions. A new experimental platform was developed to measure instability growth at the ablator-ice interface. In the deceleration phase of implosions, several experimental platforms were developed to measure both low-mode asymmetries and high-mode perturbations near peak compression with x-ray and nuclear techniques. In one innovative technique, the self-emission from the hot spot was enhanced with argon dopant to "self-backlight" the shell in-flight. To stabilize instability growth, new "adiabat-shaping" techniques were developed using the HGR platform and applied in layered DT implosions.

  17. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reverdin, Charles; Caillaud, T.; Gilleron, F.

    2012-10-15

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution {approx} 50. It has been used at the LULI-2000 laser facility at Ecole Polytechnique (France) to measure the {Delta}n = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirrormore » and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.« less

  18. KSC-2009-2155

    NASA Image and Video Library

    2009-03-17

    CAPE CANAVERAL, Fla. – At the Astrotech facility in Titusville, Fla., technicians perform backlight inspection and cleaning on NASA's Lunar Reconnaissance Orbiter, or LRO. Black light inspection uses UVA fluorescence to detect possible particulate microcontamination, minute cracks or fluid leaks. The orbiter will carry seven instruments to provide scientists with detailed maps of the lunar surface and enhance our understanding of the moon's topography, lighting conditions, mineralogical composition and natural resources. Information gleaned from LRO will be used to select safe landing sites, determine locations for future lunar outposts and help mitigate radiation dangers to astronauts. The polar regions of the moon are the main focus of the mission because continuous access to sunlight may be possible and water ice may exist in permanently shadowed areas of the poles. Accompanying LRO on its journey to the moon will be the Lunar CRater Observation and Sensing Satellite, or LCROSS, a mission that will impact the lunar surface in its search for water ice. Launch of LRO is targeted for May 20. Photo credit: NASA/Kim Shiflett

  19. Direct Observations of Graphene Dispersed in Solution by Twilight Fluorescence Microscopy.

    PubMed

    Matsuno, Yutaka; Sato, Yu-Uya; Sato, Hikaru; Sano, Masahito

    2017-06-01

    Graphene and graphene oxide (GO) in solution were directly observed by a newly developed twilight fluorescence (TwiF) microscopy. A nanocarbon dispersion was mixed with a highly concentrated fluorescent dye solution and placed in a cell with a viewing glass at the bottom. TwiF microscopy images the nanocarbon material floating within a few hundred μm of the glass surface by utilizing two optical processes to provide a faintly illuminating backlight and visualizes GO as either a dark image by absorption and energy transfer processes or a bright image by alternation of fluorophore chemistry and autofluorescence. Individual graphene and GO sheets ranging from submicron to submillimeter widths were clearly imaged at different wavelengths, which were selectable based on the dye used. Graphene could be differentiated from GO coexisting in the same solution. Partial transparency revealed layering and network structures. Motions in tumbling flow were recognized in real time. An effect of changing the solvent and the process of adhesion on the glass surface were followed in situ.

  20. An x-ray backlit Talbot-Lau deflectometer for high-energy-density electron density diagnostics.

    PubMed

    Valdivia, M P; Stutman, D; Stoeckl, C; Theobald, W; Mileham, C; Begishev, I A; Bromage, J; Regan, S P

    2016-02-01

    X-ray phase-contrast techniques can measure electron density gradients in high-energy-density plasmas through refraction induced phase shifts. An 8 keV Talbot-Lau interferometer consisting of free standing ultrathin gratings was deployed at an ultra-short, high-intensity laser system using K-shell emission from a 1-30 J, 8 ps laser pulse focused on thin Cu foil targets. Grating survival was demonstrated for 30 J, 8 ps laser pulses. The first x-ray deflectometry images obtained under laser backlighting showed up to 25% image contrast and thus enabled detection of electron areal density gradients with a maximum value of 8.1 ± 0.5 × 10(23) cm(-3) in a low-Z millimeter sized sample. An electron density profile was obtained from refraction measurements with an error of <8%. The 50 ± 15 μm spatial resolution achieved across the full field of view was found to be limited by the x-ray source-size, similar to conventional radiography.

  1. A new data processing technique for Rayleigh-Taylor instability growth experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Yongteng; Tu, Shaoyong; Miao, Wenyong

    Typical face-on experiments for Rayleigh-Taylor instability study involve the time-resolved radiography of an accelerated foil with line-of-sight of the radiography along the direction of motion. The usual method which derives perturbation amplitudes from the face-on images reverses the actual image transmission procedure, so the obtained results will have a large error in the case of large optical depth. In order to improve the accuracy of data processing, a new data processing technique has been developed to process the face-on images. This technique based on convolution theorem, refined solutions of optical depth can be achieved by solving equations. Furthermore, we discussmore » both techniques for image processing, including the influence of modulation transfer function of imaging system and the backlighter spatial profile. Besides, we use the two methods to the process the experimental results in Shenguang-II laser facility and the comparison shows that the new method effectively improve the accuracy of data processing.« less

  2. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility.

    PubMed

    Reverdin, Charles; Thais, Frédéric; Loisel, Guillaume; Busquet, M; Bastiani-Ceccotti, S; Blenski, T; Caillaud, T; Ducret, J E; Foelsner, W; Gilles, D; Gilleron, F; Pain, J C; Poirier, M; Serres, F; Silvert, V; Soullie, G; Turck-Chieze, S; Villette, B

    2012-10-01

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  3. Laser-Stimulated Fluorescence in Paleontology

    PubMed Central

    Kaye, Thomas G.; Falk, Amanda R.; Pittman, Michael; Sereno, Paul C.; Burnham, David A.; Gong, Enpu; Xu, Xing; Wang, Yinan

    2015-01-01

    Fluorescence using ultraviolet (UV) light has seen increased use as a tool in paleontology over the last decade. Laser-stimulated fluorescence (LSF) is a next generation technique that is emerging as a way to fluoresce paleontological specimens that remain dark under typical UV. A laser’s ability to concentrate very high flux rates both at the macroscopic and microscopic levels results in specimens fluorescing in ways a standard UV bulb cannot induce. Presented here are five paleontological case histories that illustrate the technique across a broad range of specimens and scales. Novel uses such as back-lighting opaque specimens to reveal detail and detection of specimens completely obscured by matrix are highlighted in these examples. The recent cost reductions in medium-power short wavelength lasers and use of standard photographic filters has now made this technique widely accessible to researchers. This technology has the potential to automate multiple aspects of paleontology, including preparation and sorting of microfossils. This represents a highly cost-effective way to address paleontology's preparatory bottleneck. PMID:26016843

  4. 3-D Modeling of Planar Target-Mount Perturbation Experiments on OMEGA

    NASA Astrophysics Data System (ADS)

    Collins, T. J. B.; Marshall, F. J.; Marozas, J. A.; Bonino, M. J.; Forties, R.; Goncharov, V. N.; Igumenshchev, I. V.; McKenty, P. W.; Smalyuk, V. A.

    2008-11-01

    OMEGA cryogenic targets are suspended in the target chamber using four spider silks attached to a C-shaped mount. The spider silks are typically composed of two entwined protein strands comparable to 1 μm in diameter. The silks and mount refract the incident laser light and cast shadows on the target surface. Experiments to measure the effects of the silks on target illumination have been performed in planar geometry using silks suspended parallel to a 20-μm-thick laser-driven target. The evolution of the surface perturbations introduced by the silks was measured using x-ray backlighting. The results of these experiments will be compared to simulations performed with DRACO, employing three-dimensional (3-D) planar hydrodynamics and a new 3-D refractive ray-trace package written specifically for this geometry. This work was supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC52-08NA28302.

  5. KSC-2009-2153

    NASA Image and Video Library

    2009-03-17

    CAPE CANAVERAL, Fla. – At the Astrotech facility in Titusville, Fla., technicians perform backlight inspection and cleaning on NASA's Lunar Reconnaissance Orbiter, or LRO. Black light inspection uses UVA fluorescence to detect possible particulate microcontamination, minute cracks or fluid leaks. The orbiter will carry seven instruments to provide scientists with detailed maps of the lunar surface and enhance our understanding of the moon's topography, lighting conditions, mineralogical composition and natural resources. Information gleaned from LRO will be used to select safe landing sites, determine locations for future lunar outposts and help mitigate radiation dangers to astronauts. The polar regions of the moon are the main focus of the mission because continuous access to sunlight may be possible and water ice may exist in permanently shadowed areas of the poles. Accompanying LRO on its journey to the moon will be the Lunar CRater Observation and Sensing Satellite, or LCROSS, a mission that will impact the lunar surface in its search for water ice. Launch of LRO is targeted for May 20. Photo credit: NASA/Kim Shiflett

  6. KSC-2009-2154

    NASA Image and Video Library

    2009-03-17

    CAPE CANAVERAL, Fla. – At the Astrotech facility in Titusville, Fla., technicians perform backlight inspection and cleaning on NASA's Lunar Reconnaissance Orbiter, or LRO. Black light inspection uses UVA fluorescence to detect possible particulate microcontamination, minute cracks or fluid leaks. The orbiter will carry seven instruments to provide scientists with detailed maps of the lunar surface and enhance our understanding of the moon's topography, lighting conditions, mineralogical composition and natural resources. Information gleaned from LRO will be used to select safe landing sites, determine locations for future lunar outposts and help mitigate radiation dangers to astronauts. The polar regions of the moon are the main focus of the mission because continuous access to sunlight may be possible and water ice may exist in permanently shadowed areas of the poles. Accompanying LRO on its journey to the moon will be the Lunar CRater Observation and Sensing Satellite, or LCROSS, a mission that will impact the lunar surface in its search for water ice. Launch of LRO is targeted for May 20. Photo credit: NASA/Kim Shiflett

  7. Solar spectral conversion for improving the photosynthetic activity in algae reactors.

    PubMed

    Wondraczek, Lothar; Batentschuk, Miroslaw; Schmidt, Markus A; Borchardt, Rudolf; Scheiner, Simon; Seemann, Benjamin; Schweizer, Peter; Brabec, Christoph J

    2013-01-01

    Sustainable biomass production is expected to be one of the major supporting pillars for future energy supply, as well as for renewable material provision. Algal beds represent an exciting resource for biomass/biofuel, fine chemicals and CO2 storage. Similar to other solar energy harvesting techniques, the efficiency of algal photosynthesis depends on the spectral overlap between solar irradiation and chloroplast absorption. Here we demonstrate that spectral conversion can be employed to significantly improve biomass growth and oxygen production rate in closed-cycle algae reactors. For this purpose, we adapt a photoluminescent phosphor of the type Ca0.59Sr0.40Eu0.01S, which enables efficient conversion of the green part of the incoming spectrum into red light to better match the Qy peak of chlorophyll b. Integration of a Ca0.59Sr0.40Eu0.01S backlight converter into a flat panel algae reactor filled with Haematococcus pluvialis as a model species results in significantly increased photosynthetic activity and algae reproduction rate.

  8. Mix and hydrodynamic instabilities on NIF

    DOE PAGES

    Smalyuk, V. A.; Robey, H. F.; Casey, D. T.; ...

    2017-06-01

    Several new platforms have been developed to experimentally measure hydrodynamic instabilities in all phases of indirect-drive, inertial confinement fusion implosions on National Ignition Facility. At the ablation front, instability growth of pre-imposed modulations was measured with a face-on, x-ray radiography platform in the linear regime using the Hydrodynamic Growth Radiography (HGR) platform. Modulation growth of "native roughness" modulations and engineering features (fill tubes and capsule support membranes) were measured in conditions relevant to layered DT implosions. A new experimental platform was developed to measure instability growth at the ablator-ice interface. Here in the deceleration phase of implosions, several experimental platformsmore » were developed to measure both low-mode asymmetries and high-mode perturbations near peak compression with x-ray and nuclear techniques. In one innovative technique, the self-emission from the hot spot was enhanced with argon dopant to "self-backlight" the shell in-flight. To stabilize instability growth, new "adiabat-shaping" techniques were developed using the HGR platform and applied in layered DT implosions.« less

  9. Study of ablation and implosion stages in wire arrays using coupled ultraviolet and X-ray probing diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, A. A.; Ivanov, V. V.; Astanovitskiy, A. L.

    2015-11-15

    Star and cylindrical wire arrays were studied using laser probing and X-ray radiography at the 1-MA Zebra pulse power generator at the University of Nevada, Reno. The Leopard laser provided backlighting, producing a laser plasma from a Si target which emitted an X-ray probing pulse at the wavelength of 6.65 Å. A spherically bent quartz crystal imaged the backlit wires onto X-ray film. Laser probing diagnostics at the wavelength of 266 nm included a 3-channel polarimeter for Faraday rotation diagnostic and two-frame laser interferometry with two shearing interferometers to study the evolution of the plasma electron density at the ablation and implosionmore » stages. Dynamics of the plasma density profile in Al wire arrays at the ablation stage were directly studied with interferometry, and expansion of wire cores was measured with X-ray radiography. The magnetic field in the imploding plasma was measured with the Faraday rotation diagnostic, and current was reconstructed.« less

  10. Modeling of Multi-Kilovolt X-ray Driven Ablation and Closure of Pinholes during Point-Projection Backlit Imaging

    NASA Astrophysics Data System (ADS)

    Bullock, A. B.; Landen, O. L.; Bradley, D. K.

    2000-10-01

    Pinhole-assisted point-projection backlighting of large samples with few µm pinholes can result in pinhole closure due to x-ray driven ablation of the high Z pinhole substrate, thereby potentially limiting the usefulness of this imaging method. The results of a previous study[1] using streaked 1-D backlit imaging of 25 mm W wires at the OMEGA laser are compared to simulations produced by HYADES, a 1-D Lagrangian hydrodynamics code. Interestingly, the observed image resolution stays fixed while the pinhole transmission drops within 1-2 ns, suggesting rapid filling by a long scale-length of low density substrate material. These results will be compared to time-dependent HYADES predictions of pinhole closure timescales and resolution. 1 A.B. bullock, D.K. Bradley, and O.L. Landen, to be published in RSI (2001). *This work was performed under the auspices of the U.S. Department of Energy by University of California/Lawrence Livermore National Laboratory under Contract No. W-7405-Eng-48.

  11. High-energy (> 70 KeV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    DOE PAGES

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; ...

    2017-03-16

    Here, the Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20–30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4–9 × 10 –4 for x-rays with energies greater thanmore » 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.« less

  12. An Experimental Investigation of the Flow Over the Rear End of a Notchback Automobile Configuration

    NASA Technical Reports Server (NTRS)

    Jenkins, Luther N.

    2000-01-01

    An experimental investigation of the flow over the rear end of a 0.16 scale notchback automobile configuration has been conducted in the NASA Langley Basic Aerodynamics Research Tunnel (BART). The objective of this work was to investigate the flow separation that occurs behind the backlight and obtain experimental data that can be used to understand the physics and time-averaged structure of the flow field. A three-component laser velocimeter was used to make non-intrusive, velocity measurements in the center plane and in a single cross-flow plane over the decklid. In addition to off-body measurements, flow conditions on the car surface were documented via surface flow visualization, boundary layer measurements, and surface pressures. The experimental data show several features previously identified by other researchers, but also reveal differences between the flow field associated with this particular configuration and the generally accepted models for the flow over a notchback rear end.

  13. Emerging trends in X-ray spectroscopic studies of plasma produced by intense laser beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arora, V., E-mail: arora@rrcat.gov.in; Chakera, J. A.; Naik, P. A.

    2015-07-31

    X-ray line emission from hot dense plasmas, produced by ultra-short high intensity laser systems, has been studied experimentally in recent years for applications in materials science as well as for back-lighter applications. By virtue of the CPA technology, several laser facilities delivering pulses with peak powers in excess of one petawatt (focused intensities > 10{sup 20} W-cm{sup −2}) have either been commissioned across the globe during the last few years or are presently under construction. On the other hand, hard x-ray sources on table top, generating ultra-short duration x-rays at a repetition rate up to 10 kHz, are routinely available formore » time resolved x-ray diffraction studies. In this paper, the recent experiments on x-ray spectroscopic studies of plasma produced by 45 fs, Ti:sapphire laser pulses (focused iintensity > 10{sup 18} W-cm{sup −2}) at RRCAT Indore will be presented.« less

  14. Microgravity

    NASA Image and Video Library

    2001-01-24

    This photo shows the Handheld Diffusion Test Cell (HH-DTC) apparatus flown on the Space Shuttle. Similar cells (inside the plastic box) will be used in the Observable Protein Crystal Growth Apparatus (OPCGA) to be operated aboard the International Space Station (ISS). The principal investigator is Dr. Alex McPherson of the University of California, Irvine. Each individual cell comprises two sample chambers with a rotating center section that isolates the two from each other until the start of the experiment and after it is completed. The cells are made from optical-quality quartz glass to allow photography and interferometric observations. Each cell has a small light-emitting diode and lens to back-light the solution. In protein crystal growth experiments, a precipitating agent such as a salt solution is used to absorb and hold water but repel the protein molecules. This increases the concentration of protein until the molecules nucleate to form crystals. This cell is one of 96 that make up the experiment module portion of the OPCGA.

  15. Microgravity

    NASA Image and Video Library

    2001-01-24

    This photo shows an individual cell from the Handheld Diffusion Test Cell (HH-DTC) apparatus flown on the Space Shuttle. Similar cells will be used in the Observable Protein Crystal Growth Apparatus (OPCGA) to be operated aboard the International Space Station (ISS). The principal investigator is Dr. Alex McPherson of the University of California, Irvine. Each individual cell comprises two sample chambers with a rotating center section that isolates the two from each other until the start of the experiment and after it is completed. The cells are made from optical-quality quartz glass to allow photography and interferometric observations. Each cell has a small light-emitting diode and lens to back-light the solution. In protein crystal growth experiments, a precipitating agent such as a salt solution is used to absorb and hold water but repel the protein molecules. This increases the concentration of protein until the molecules nucleate to form crystals. This cell is one of 96 that make up the experiment module portion of the OPCGA.

  16. Development and evaluation of amusement machine using autostereoscopic 3D display

    NASA Astrophysics Data System (ADS)

    Kawai, Takashi; Shibata, Takashi; Shimizu, Yoichi; Kawata, Mitsuhiro; Suto, Masahiro

    2004-05-01

    Pachinko is a pinball-like game peculiar to Japan, and is one of the most common pastimes around the country. Recently, with the videogame market contracting, various multimedia technologies have been introduced into Pachinko machines. The authors have developed a Pachinko machine incorporating an autostereoscopic 3D display, and evaluated its effect on the visual function. As of April 2003, the new Pachinko machine has been on sale in Japan. The stereoscopic 3D image is displayed using an LCD. Backlighting for the right and left images is separate, and passes through a polarizing filter before reaching the LCD, which is sandwiched with a micro polarizer. The content selected for display was ukiyoe pictures (Japanese traditional woodblocks). The authors intended to reduce visual fatigue by presenting 3D images with depth "behind" the display and switching between 3D and 2D images. For evaluation of the Pachinko machine, a 2D version with identical content was also prepared, and the effects were examined and compared by testing psycho-physiological responses.

  17. Replicating the Z iron opacity experiments on the NIF

    NASA Astrophysics Data System (ADS)

    Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Ross, P. W.; Kline, J. L.; Flippo, K. A.; Sherrill, M. E.; Dodd, E. S.; DeVolder, B. G.; Cardenas, T.; Archuleta, T. N.; Craxton, R. S.; Zhang, R.; McKenty, P. W.; Garcia, E. M.; Huffman, E. J.; King, J. A.; Ahmed, M. F.; Emig, J. A.; Ayers, S. L.; Barrios, M. A.; May, M. J.; Schneider, M. B.; Liedahl, D. A.; Wilson, B. G.; Urbatsch, T. J.; Iglesias, C. A.; Bailey, J. E.; Rochau, G. A.

    2017-06-01

    X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity of iron at a temperature of ∼160 eV and an electron density of ∼7 × 1021 cm-3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.

  18. A Photometric Technique for Determining Fluid Concentration using Consumer-Grade Hardware

    NASA Technical Reports Server (NTRS)

    Leslie, F.; Ramachandran, N.

    1999-01-01

    In support of a separate study to produce an exponential concentration gradient in a magnetic fluid, a noninvasive technique for determining, species concentration from off-the-shelf hardware has been developed. The approach uses a backlighted fluid test cell photographed with a commercial digital camcorder. Because the light extinction coefficient is wavelength dependent, tests were conducted to determine the best filter color to use, although some guidance was also provided using an absorption spectrophotometer. With the appropriate filter in place, the provide attenuation of the light passing, through the test cell was captured by the camcorder. The digital image was analyzed for intensity using, software from Scion Image Corp. downloaded from the Internet. The analysis provides a two-dimensional array of concentration with an average error of 0.0095 ml/ml. This technique is superior to invasive techniques, which require extraction of a sample that disturbs the concentration distribution in the test cell. Refinements of this technique using a true monochromatic laser light Source are also discussed.

  19. Simulations of the interaction of intense petawatt laser pulses with dense Z-pinch plasmas : final report LDRD 39670.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, Dale Robert; MacFarlane, Joseph John; Mehlhorn, Thomas Alan

    We have studied the feasibility of using the 3D fully electromagnetic implicit hybrid particle code LSP (Large Scale Plasma) to study laser plasma interactions with dense, compressed plasmas like those created with Z, and which might be created with the planned ZR. We have determined that with the proper additional physics and numerical algorithms developed during the LDRD period, LSP was transformed into a unique platform for studying such interactions. Its uniqueness stems from its ability to consider realistic compressed densities and low initial target temperatures (if required), an ability that conventional PIC codes do not possess. Through several testmore » cases, validations, and applications to next generation machines described in this report, we have established the suitability of the code to look at fast ignition issues for ZR, as well as other high-density laser plasma interaction problems relevant to the HEDP program at Sandia (e.g. backlighting).« less

  20. Organic light emitters gain longevity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Service, R.E.

    1996-08-16

    Organic thin-film displays were for many years a research curiosity with no staying power. Now their stamina is beginning to match their unbeatable toughness and lightness. For much of the past decade, researchers have been promising to put thin films of light-emitting plastics and other organic materials on display: large, flexible, inexpensive and efficient screens to be used for everything from lightweight backlights for computer displays to TVs that you can hang flat on the wall or roll up and put in your pocket. Yet, many of these promises have fallen flat as well. Organic lights have tended to burnmore » out after just days or weeks of operation. But now long-lived organic thin film displays are beginning to shine. By crafting films without as many burnout causing defects and building devices with additional film layers to enhance light emission, researchers around the work have recently improved the brightness, lifetime, and future prosects of their devices. This article describes recent developments and improvements in the field.« less

Top