Mulliken, J B; Giargiana, F A; Claybaugh, G J; Hoopes, J E
1975-07-01
A long-term cineradiographic follow-up study of twenty patients with velo-pharyngeal incompetence fails to demonstrate predictable retrodisplacement of the levator insertion following combined levator retropositioning, pushback, and pharyngeal flap procedures. Simple levator retropositioning gave posterior displacement in the two patients evaluated. Patients with normal or posterior levator insertions pre-operatively all demonstrated post-operative anterior displacement following pharyngeal flap procedures, either alone or in combination with pushback. Anterior levator displacement may be the result of scar contraction or division of the levator sling (during insetting of a pharyngeal flap). Pre-operative and post-operative speech evaluation demonstrated substantial improvement in all except 3 patients; 2 of the poor speech results were patients with demonstrated levator retrodisplacement on post-operative cineradiography.
Numerical Correlation of Levator Advancement in Preoperative Planning.
Makeeva, Valeria; Collawn, Sherry S; Pierce, Evelina N; Mousa, Mina S; Yang, Jennifer H; Davison, Peter N; Jospitre, Elodie C
2017-06-01
Several procedures have been proposed for the treatment of eyelid ptosis, and both levator advancement and levator plication are widely used to shorten the levator palpebrae superioris. The purpose of this study was to quantify perioperative lid measurements in patients undergoing bilateral levator aponeurosis advancements to aid in preoperative planning. Between July 2014 and June 2016, the authors performed a retrospective analysis of all bilateral upper eyelid levator advancement procedures for ptosis performed by the senior surgeon. There are a total of 21 patients (6 men and 15 women) with a mean age of 63 years (range, 48-79 years). The average time at follow-up was 5.3 months, with a range of 1 to 26 months. In this retrospective study, we collected data on presurgical measurements including marginal reflex distance 1 (MRD1), surgical technique used (symmetrical/asymmetrical levator advancement) with millimeters of advancement used, and postsurgical measurements. We found that on average, an advancement of 4 mm led to an improvement in MRD1 of 2.26 mm (n = 14), and advancement of 5 mm led to an improvement in MRD1 of 2.74 mm (n = 15). Patients also reported improvements in their quality of life. Our results may be used to guide clinicians in preoperative planning.
Bovine Acellular Dermal Matrix for Levator Lengthening in Thyroid-Related Upper-Eyelid Retraction.
Sun, Jing; Liu, Xingtong; Zhang, Yidan; Huang, Yazhuo; Zhong, Sisi; Fang, Sijie; Zhuang, Ai; Li, Yinwei; Zhou, Huifang; Fan, Xianqun
2018-05-02
BACKGROUND Eyelid retraction is the most common and often the first sign of thyroid eye disease (TED). Upper-eyelid retraction causes both functional and cosmetic problems. In order to correct the position of the upper eyelid, surgery is required. Many procedures have demonstrated good outcomes in mild and moderate cases; however, unpredictable results have been obtained in severe cases. Dryden introduced an upper-eyelid-lengthening procedure, which used scleral grafts, but outcomes were unsatisfactory. A new technique is introduced in this study as a reasonable alternative for TED-related severe upper-eyelid retraction correction. MATERIAL AND METHODS An innovative technique for levator lengthening using bovine acellular dermal matrix as a spacer graft is introduced for severe upper-eyelid retraction secondary to TED. Additionally, 2 modifications were introduced: the fibrous cords scattered on the surface of the levator aponeurosis were excised and the orbital fat pad anterior to the aponeurosis was dissected and sutured into the skin closure in a "skin-tarsus-fat-skin" fashion. RESULTS The modified levator-lengthening surgery was performed on 32 eyelids in 26 patients consisting of 21 women and 5 men (mean age, 37.8 years; age range, 19-67 years). After corrective surgery, the average upper margin reflex distance was lowered from 7.7±0.85 mm to 3.3±0.43 mm. Eighteen cases (69%) had perfect results, while 6 cases (23%) had acceptable results. CONCLUSIONS A modified levator-lengthening procedure using bovine acellular dermal matrix as a spacer graft ameliorated both the symptoms and signs of severe upper-eyelid retraction secondary to TED. This procedure is a reasonable alternative for correction of TED-related severe upper-eyelid retraction.
Bovine Acellular Dermal Matrix for Levator Lengthening in Thyroid-Related Upper-Eyelid Retraction
Sun, Jing; Liu, Xingtong; Zhang, Yidan; Huang, Yazhuo; Zhong, Sisi; Fang, Sijie; Zhuang, Ai; Li, Yinwei; Zhou, Huifang
2018-01-01
Background Eyelid retraction is the most common and often the first sign of thyroid eye disease (TED). Upper-eyelid retraction causes both functional and cosmetic problems. In order to correct the position of the upper eyelid, surgery is required. Many procedures have demonstrated good outcomes in mild and moderate cases; however, unpredictable results have been obtained in severe cases. Dryden introduced an upper-eyelid-lengthening procedure, which used scleral grafts, but outcomes were unsatisfactory. A new technique is introduced in this study as a reasonable alternative for TED-related severe upper-eyelid retraction correction. Material/Methods An innovative technique for levator lengthening using bovine acellular dermal matrix as a spacer graft is introduced for severe upper-eyelid retraction secondary to TED. Additionally, 2 modifications were introduced: the fibrous cords scattered on the surface of the levator aponeurosis were excised and the orbital fat pad anterior to the aponeurosis was dissected and sutured into the skin closure in a “skin-tarsus-fat-skin” fashion. Results The modified levator-lengthening surgery was performed on 32 eyelids in 26 patients consisting of 21 women and 5 men (mean age, 37.8 years; age range, 19–67 years). After corrective surgery, the average upper margin reflex distance was lowered from 7.7±0.85 mm to 3.3±0.43 mm. Eighteen cases (69%) had perfect results, while 6 cases (23%) had acceptable results. Conclusions A modified levator-lengthening procedure using bovine acellular dermal matrix as a spacer graft ameliorated both the symptoms and signs of severe upper-eyelid retraction secondary to TED. This procedure is a reasonable alternative for correction of TED-related severe upper-eyelid retraction. PMID:29718902
Khatavi, Fatima; Nasrollahi, Kobra; Zandi, Alireza; Panahi, Maryam; Mortazavi, Mahshid; Pourazizi, Mohsen; Ranjbar-Omidi, Behzad
2017-01-01
Upper eyelid retraction is a characteristic feature of thyroid eye disease, including Graves' orbitopathy. In this study, a new surgical technique for correction of lid retraction secondary to Graves' orbitopathy is described. Sixteen eyelids of patients older than 18 years old underwent surgical correction for moderate to severe lid retraction secondary to Graves' orbitopathy. In this procedure, levator aponeurectomy was performed via a transconjunctival approach. Upper marginal reflex distance (MRD1) was measured before the surgery and at 1 week, 3 months, and 6 months after the surgery. MRD1 was reduced significantly from preoperatively (mean: 7.84 mm) to 1 week after the surgery (mean: 3.59 mm) (P < 0.001). Three and six months after surgery, mean MRD1 was 5.09 mm and 5.10 mm, respectively, showing that lid retraction was improved significantly (P < 0.001). Lateral levator aponeurectomy via the transconjunctival approach is a simple, scar-less, quick procedure that has optimal stable outcome.
Tsukada, Yuichiro; Ito, Masaaki; Watanabe, Kentaro; Yamaguchi, Kumiko; Kojima, Motohiro; Hayashi, Ryuichi; Akita, Keiichi; Saito, Norio
2016-05-01
Intersphincteric resection has become a widely used treatment for patients with rectal cancer. However, the detailed anatomy of the anal canal related to this procedure has remained unclear. The purpose of this study was to clarify the detailed anatomy of the anal canal. This is a descriptive study. Histologic evaluations of paraffin-embedded tissue specimens were conducted at a tertiary referral hospital. Tissue specimens were obtained from cadavers of 5 adults and from 13 patients who underwent abdominoperineal resection for rectal cancer. Sagittal sections from 9 circumferential portions of the cadaveric anal canal (histologic staining) and 3 circumferential portions from patients were studied (immunohistochemistry for smooth and skeletal muscle fibers). Longitudinal fibers between the internal and external anal sphincters consisted primarily of smooth muscle fibers that continued from the longitudinal muscle of the rectum. The levator ani muscle attached directly to the lateral surface of the longitudinal smooth muscle of the rectum. The length of the attachment was longer in the anterolateral portion and shorter in the posterior portion of the anal canal. In the lateral and posterior portions, the levator ani muscle partially overlapped the external anal sphincter; however, there was less overlap in the anterolateral portion. In the posterior portion, thick smooth muscle was present on the surface of the levator ani muscle and it continued to the longitudinal muscle of the rectum. We observed only limited portions in some surgical specimens because of obstruction by tumors. The levator ani muscle attaches directly to the longitudinal muscle of the rectum. The spatial relationship between the smooth and skeletal muscles differed in different portions of the anal canal. For intersphincteric resection, dissection must be performed between the longitudinal muscle of the rectum and the levator ani muscle/external anal sphincter, and the appropriate surgical lines must be selected based on the specific structural characteristics of each portion.
Control-surface hinge-moment calculations for a high-aspect-ratio supercritical wing
NASA Technical Reports Server (NTRS)
Perry, B., III
1978-01-01
The hinge moments, at selected flight conditions, resulting from deflecting two trailing edge control surfaces (one inboard and one midspan) on a high aspect ratio, swept, fuel conservative wing with a supercritical airfoil are estimated. Hinge moment results obtained from procedures which employ a recently developed transonic analysis are given. In this procedure a three dimensional inviscid transonic aerodynamics computer program is combined with a two dimensional turbulent boundary layer program in order to obtain an interacted solution. These results indicate that trends of the estimated hinge moment as a function of deflection angle are similar to those from experimental hinge moment measurements made on wind tunnel models with swept supercritical wings tested at similar values of free stream Mach number and angle of attack.
Control-surface hinge-moment calculations for a high-aspect-ratio supercritical wing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perry, B.I.
1978-09-01
The hinge moments, at selected flight conditions, resulting from deflecting two trailing edge control surfaces (one inboard and one midspan) on a high aspect ratio, swept, fuel conservative wing with a supercritical airfoil are estimated. Hinge moment results obtained from procedures which employ a recently developed transonic analysis are given. In this procedure a three dimensional inviscid transonic aerodynamics computer program is combined with a two dimensional turbulent boundary layer program in order to obtain an interacted solution. These results indicate that trends of the estimated hinge moment as a function of deflection angle are similar to those from experimentalmore » hinge moment measurements made on wind tunnel models with swept supercritical wings tested at similar values of free stream Mach number and angle of attack.« less
Outcomes of levator resection at tertiary eye care center in Iran: a 10-year experience.
Abrishami, Alireza; Bagheri, Abbas; Salour, Hossein; Aletaha, Maryam; Yazdani, Shahin
2012-02-01
To assess outcomes of levator resection for the surgical correction of congenital and acquired upper lid ptosis in patients with fair to good levator function and evaluation of the relationship between demographic data and success of this operation. In a retrospective study, medical records of patients with blepharoptosis who had undergone levator resection over a 10-year period and were followed for at least 3 months were reviewed. Overall, 136 patients including 60 (44.1%) male and 76 (55.9%) female subjects with a mean age of 20 ± 13.8 years (range, 2 to 80 years) were evaluated, of whom 120 cases (88.2%) had congenital ptosis and the rest had acquired ptosis. The overall success rate after the first operation was 78.7%. The most common complication after the first operation was undercorrection in 26 cases (19.1%), which was more prevalent among young patients (p = 0.06). Lid fissure and margin reflex distance (MRD(1)) also increased after levator resection (p < 0.001). Age, sex, type of ptosis, amblyopia, levator function, MRD(1), lid fissure and spherical equivalent were not predictive of surgical outcomes of levator resection. Levator resection has a high rate of success and few complications in the surgical treatment of congenital and acquired upper lid ptosis with fair to good levator function. Reoperation can be effective in most cases in which levator resection has been performed.
Aydin, Serdar; Bakar, Rabia Zehra; Arioğlu Aydin, Çağri; Ateş, Seda
The aim of this study is to investigate the association of sexual functions with levator hiatus biometry measurements and levator ani muscle defect. In 62 heterosexual, sexually active premenopausal women without pelvic floor disorders or urinary incontinence, 3-dimensional transperineal ultrasound imaging was used. Two 3-dimensional volumes were recorded, one at rest and one on Valsalva maneuver. Levator biometry measurements and levator defect were evaluated in an axial plane. Sexual function was assessed by a validated questionnaire, Female Sexual Function Index (FSFI). The primary outcome measure was correlation of sexual functions with the levator hiatus area, transverse and anteroposterior diameters, levator ani muscle thickness, vaginal length, and changes in measurements with Valsalva and levator defect. Forty-two women (67.7%) had low total FSFI scores (<26.55). Levator defect rates were similar in female sexual dysfunction (7/42, 16.7%) and women without female sexual dysfunction (5/20, 25%). The FSFI was negatively and weakly correlated with Δhiatal anteroposterior diameter (r = -0.33, P < 0.009) in the study population. There was a weak and inverse correlation between Δhiatal anteroposterior diameter and arousal (r = -0.35, P < 0.002), desire (r = -0.38, P < 0.001), and orgasm (r = -0.33, P < 0.007). Pain and lubrication did not correlate with any measurement. Hiatal area and diameters at rest are not related to sexual functions. Changes in anteroposterior diameter of the levator hiatus during Valsalva, which may be a sign of pelvic floor laxity or levator muscle weakness, are weakly associated with sexual functions, particularly desire, arousal, and orgasm domains.
Notten, Kim J B; Vergeldt, Tineke F M; van Kuijk, Sander M J; Weemhoff, Mirjam; Roovers, Jan-Paul W R
The aim of this study was to assess the diagnostic accuracy and clinical implications of translabial 3-dimensional (3D) ultrasound for the assessment of levator ani defects and biometry in women with pelvic organ prolapse (POP). We performed a systematic literature search through computerized databases including MEDLINE (via PubMed), EMBASE (via OvidSP), and the Cochrane Library using both medical subject headings and text terms from January 1, 2003, to December 25, 2015.We included articles that reported on POP status and diagnostic accuracy measurements with translabial 3D ultrasound or transperineal ultrasound for the detection of levator ani defects or for measuring pelvic floor biometry, that is, levator ani hiatus, or reported on the clinical relevance of using translabial 3D ultrasound for levator ani defects or measuring pelvic floor biometry in women with POP. Thirty-one articles were selected in accordance with parts of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines that can be applied to studies of diagnostic accuracy. Twenty-two articles (71%) are coauthored by 1 expert in this field. Detecting levator ani defects with translabial 3D ultrasound compared with magnetic resonance imaging showed a moderate to good agreement, whereas measuring hiatal biometry on translabial 3D ultrasound compared with magnetic resonance imaging showed a moderate to very good agreement.The interobserver agreement for diagnosing levator ani defects and measuring the levator hiatal area showed a moderate to very good agreement. Furthermore, levator ani defects increase the risk of cystocele and uterine prolapse, and levator ani defects are associated with recurrent POP.Finally, a larger hiatus was associated with POP and recurrent POP. Translabial 3D ultrasound is reproducible for diagnosing levator ani defects and ballooning hiatus. Both levator ani defects and a larger hiatal area are, in a selected population of patients with pelvic floor dysfunction, associated with POP and recurrent POP. More research is needed concerning external validation because most data in this article are coauthored by 1 expert in this field.
NASA Technical Reports Server (NTRS)
Konagaya, Masaaki; Max, Stephen R.
1986-01-01
RU38486, a potent and selective antiglucocorticoid, was employed to study a possible role for endogenous glucocorticoids in atrophy of the levator ani muscle secondary to castration of male rats. RU38486 was shown to block (3H) triamcinolone acetonide binding to cytosol from levator ani muscle. Daily oral administration of RU38486 to castrated rats partially prevented atrophy of the levator ani muscle, as well as a decrease in RNA concentration. In a control group receiving RU38486 alone, the levator ani underwent significant 20 percent hypertrophy. Administration of exogenous dexamethasone also caused pronounced atrophy of the levator ani muscle. This atrophy was prevented, to a significant degree, by simultaneous oral administration of Ru38486. It is concluded that endogenous glucocorticoids, the actions of which are blocked by RU38486, may be involved in regulation of the mass of the levator ani muscle in intact rats.
NASA Technical Reports Server (NTRS)
Konagaya, M.; Max, S. R.
1985-01-01
RU38486, a potent and selective antiglucocorticoid, was employed to study a possible role for endogenous glucocorticoids in atrophy of the levator ani muscle secondary to castration of male rats. RU38486 was shown to block (3H) triamcinolone acetonide binding to cytosol from levator ani muscle. Daily oral administration of RU38486 to castrated rats partially prevented atrophy of the levator ani muscle, as well as a decrease in RNA concentration. In a control group receiving RU38486 alone, the levator ani underwent significant (20%) hypertrophy. Administration of exogenous dexamethasone also caused pronounced atrophy of the levator ani muscle. This atrophy was prevented, to a significant degree, by simultaneous oral administration of RU38486. It is concluded that endogenous glucocorticoids, the actions of which are blocked by RU38486, may be involved in regulation of the mass of the levator ani muscle in intact rats.
Ji, Chenyang; Li, Ruiting; He, Wei; Zhang, Jinming
2018-03-01
Some fordless-eyelid patients with moderate upper lid ptosis characterize in a higher eyebrow position which leads to an increased midfacial ratio. Apart from performing blepharoplasty to create dynamic folds, additional procedures such as folding aponeurosis of levator palpebrae superioris muscle were effective to revise the enlarged ratio of midface through lowering eyebrow, which gains good aesthetic results. However, the specific changes in the proportion of facial aesthetics and the importance of these change were serious lack in the literature as far as the authors know. To measure the ratio of the length between upper edge of eyebrow and edge of lower eyelid (L1)/the length between edge of lower eyelid and nasal base (L2) in the fordless-eyelid and upper lid ptosis patients who received levator aponeurosis folding surgery, and to analyze the change in the proportion of midfacial aesthetics. From December 2015 to October 2016, the pre- and postoperative photographs from 21 cases of patients with foldless eyelid and upper lid ptosis who underwent the levator aponeurosis folding procedures in the authors' department were collected as study group. Additional full-face pictures of 20 Chinese female movie stars were prepared as control group. The ratios of L1/ L2 (J) were measured via Adobe Photoshop CS6. The statistical significance was analyzed and the change of midfacial proportion was evaluated. In the study group, the mean value of preoperative L1/L2 (J1) is 0.746, and (J2) 0.657 postoperatively. In the control group, the mean value of L1/L2 (J3) is 0.667. Statistical differences showed between the pre- and postoperative samples and between preoperative samples and control group. There was no statistical difference between postoperative samples and control group samples. The ratios between L1 and L2 in postoperative samples are close to those in the control group, which are closer to the golden radio. Levator aponeurosis folding can effectively lower eyebrow in patients with upper lid ptosis, shortening the length between eyebrow and lower eyelid, and therefore harvesting a more appropriate and harmonious ratio of L1/ L2 according to the golden section theory. The changes in the proportion of midfacial aesthetics after operation could be used as a key point in the preoperative communication and postoperative effect evaluation, besides the size of palpebral fissure and corneal exposure rate.
Curvature estimation for multilayer hinged structures with initial strains
NASA Astrophysics Data System (ADS)
Nikishkov, G. P.
2003-10-01
Closed-form estimate of curvature for hinged multilayer structures with initial strains is developed. The finite element method is used for modeling of self-positioning microstructures. The geometrically nonlinear problem with large rotations and large displacements is solved using step procedure with node coordinate update. Finite element results for curvature of the hinged micromirror with variable width is compared to closed-form estimates.
Levator hiatal area as a risk factor for cystocele recurrence after surgery: a prospective study.
Vergeldt, T F M; Notten, K J B; Weemhoff, M; van Kuijk, S M J; Mulder, F E M; Beets-Tan, R G; Vliegen, R F A; Gondrie, E T C M; Bergmans, M G M; Roovers, J P W R; Kluivers, K B
2015-07-01
To investigate whether increased levator hiatal area, measured preoperatively, was independently associated with anatom-ical cystocele recurrence 12 months after anterior colporrhaphy. Multicentre prospective cohort study. Nine teaching hospitals in the Netherlands. Women planned for conventional anterior colporrhaphy without mesh. Women underwent physical examination, translabial three-dimensional (3D) ultrasound and magnetic resonance imaging (MRI) prior to surgery. At 12 months after surgery the physical examination was repeated. Women with and without anatomical cystocele recurrence were compared to assess the association with levator hiatal area on 3D ultrasound, levator hiatal area on MRI, and potential confounding factors. The receiver operating characteristic (ROC) curve was created to quantify the discriminative ability of using levator hiatal area to predict anatomical cystocele recurrence. Of 139 included women, 76 (54.7%) had anatomical cystocele recurrence. Preoperative stage 3 or 4 and increased levator hiatal area during Valsalva on ultrasound were significantly associated with cystocele recurrence, with odds ratios of 3.47 (95% confidence interval, 95% CI 1.66-7.28) and 1.06 (95% CI 1.01-1.11) respectively. The area under the ROC curve was 0.60 (95% CI 0.51-0.70) for levator hiatal area during Valsalva on ultrasound, and 0.65 (95% CI 0.55-0.71) for preoperative Pelvic Organ Prolapse Quantification (POP-Q) stage. Increased levator hiatal area during Valsalva on ultrasound prior to surgery and preoperative stage 3 or 4 are independent risk factors for anatomical cystocele recurrence after anterior colporrhaphy; however, increased levator hiatal area as the sole factor for predicting anatomical cystocele recurrence after surgery shows poor test characteristics. © 2015 Royal College of Obstetricians and Gynaecologists.
Levator Muscle Enlargement in Thyroid Eye Disease-Related Upper Eyelid Retraction.
Davies, Michael J; Dolman, Peter J
To identify levator palpebrae superioris enlargement in thyroid eye disease (TED)-related upper eyelid retraction (ULR). Retrospective case-control. Subjects included 50 consecutive patients with unilateral thyroid eye disease-related ULR ≥ 2 mm and no previous eyelid surgery. The contralateral side was used as control. Clinical information was recorded from charts. CT scans were assessed by investigators blinded to the clinical data. A prediction of retracted side was made based on CT scan appearance and on basis of measured levator palpebrae superioris cross-sectional area at 2 defined points. Statistical analysis determined correlation between levator palpebrae superioris size and presence of ULR. The study was approved by the institutional ethics committee. Side with ULR predicted from CT scan review in over 85% of cases. Mean cross-sectional area of levator palpebrae superioris on retracted side was significantly larger than nonretracted side at 2 separate sites. Levator palpebrae superioris area was larger on retracted side compared with nonretracted side in over 85% of subjects. More than 30% of subjects had no enlargement of other extraocular muscles. Only 6% of patients had enlargement of the ipsilateral inferior rectus muscle. Levator palpebrae superioris enlargement from inflammation or scar is a factor in thyroid eye disease-related ULR. Upper eyelid retraction can be predicted from CT scan appearance in over 85% of cases. Ipsilateral inferior rectus enlargement is rare. Levator palpebrae superioris is the most commonly targeted muscle in thyroid eye disease.
Castelein, Birgit; Cagnie, Barbara; Parlevliet, Thierry; Danneels, Lieven; Cools, Ann
2015-10-01
To identify maximum voluntary isometric contraction (MVIC) test positions for the deeper-lying scapulothoracic muscles (ie, levator scapulae, pectoralis minor, rhomboid major), and to provide a standard set of a limited number of test positions that generate an MVIC in all scapulothoracic muscles. Cross-sectional study. Physical and rehabilitation medicine department. Healthy subjects (N=21). Not applicable. Mean peak electromyographic activity from levator scapulae, pectoralis minor, and rhomboid major (investigated with fine-wire electromyography) and from upper trapezius, middle trapezius, lower trapezius, and serratus anterior (investigated with surface electromyography) during the performance of 12 different MVICs. The results indicated that various test positions generated similar high mean electromyographic activity and that no single test generated maximum activity for a specific muscle in all subjects. The results of this study support using a series of test positions for normalization procedures rather than a single exercise to increase the likelihood of recruiting the highest activity in the scapulothoracic muscles. A standard set of 5 test positions was identified as being sufficient for generating an MVIC of all scapulothoracic muscles: seated T, seated U 135°, prone T-thumbs up, prone V-thumbs up, and supine V-thumbs up. A standard set of test positions for normalization of scapulothoracic electromyographic data that also incorporates the levator scapulae, pectoralis minor, and rhomboid major muscles is 1 step toward a more comprehensive understanding of normal and abnormal muscle function of these muscles and will help to standardize the presentation of scapulothoracic electromyographic muscle activity. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Androgen-estrogen synergy in rat levator ani muscle Glucose-6-phosphate dehydrogenase
NASA Technical Reports Server (NTRS)
Max, S. R.
1984-01-01
The effects of castration and hormone administration on the activity of glucose-6-phosphate dehydrogenase in the rat levator ani muscle were studied. Castration caused a decrease in enzyme activity and in wet weight of the levator ani muscle. Chronic administration of testosterone propionate increased glucose-6-phosphate dehydrogenase activity in the levator ani muscle of castrated rats; the magnitude of the recovery of enzyme activity was related to the length of time of exposure to testosterone propionate after castration as well as to the length of time the animals were castrated. The longer the period of castration before exposure to testosterone propionate, the greater the effect. This result may be related to previously reported castration-mediated increases in androgen receptor binding in muscle. Dihydrotestosterone was less effective than testosterone propionate in enhancing glucose-6-phosphate dehydrogenase activity in the levator ani muscle from castrated rats; estradiol-17-beta alone was ineffective. Combined treatment with estradiol-17-beta and dihydrotestosterone, however, was as effective as testosterone alone. Thus, androgens and estrogens may exert synergistic effects on levator ani muscle.
Speksnijder, L; Rousian, M; Steegers, E A P; Van Der Spek, P J; Koning, A H J; Steensma, A B
2012-07-01
Virtual reality is a novel method of visualizing ultrasound data with the perception of depth and offers possibilities for measuring non-planar structures. The levator ani hiatus has both convex and concave aspects. The aim of this study was to compare levator ani hiatus volume measurements obtained with conventional three-dimensional (3D) ultrasound and with a virtual reality measurement technique and to establish their reliability and agreement. 100 symptomatic patients visiting a tertiary pelvic floor clinic with a normal intact levator ani muscle diagnosed on translabial ultrasound were selected. Datasets were analyzed using a rendered volume with a slice thickness of 1.5 cm at the level of minimal hiatal dimensions during contraction. The levator area (in cm(2)) was measured and multiplied by 1.5 to get the levator ani hiatus volume in conventional 3D ultrasound (in cm(3)). Levator ani hiatus volume measurements were then measured semi-automatically in virtual reality (cm(3) ) using a segmentation algorithm. An intra- and interobserver analysis of reliability and agreement was performed in 20 randomly chosen patients. The mean difference between levator ani hiatus volume measurements performed using conventional 3D ultrasound and virtual reality was 0.10 (95% CI, - 0.15 to 0.35) cm(3). The intraclass correlation coefficient (ICC) comparing conventional 3D ultrasound with virtual reality measurements was > 0.96. Intra- and interobserver ICCs for conventional 3D ultrasound measurements were > 0.94 and for virtual reality measurements were > 0.97, indicating good reliability for both. Levator ani hiatus volume measurements performed using virtual reality were reliable and the results were similar to those obtained with conventional 3D ultrasonography. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Seismic Performance Evaluation of Reinforced Concrete Frames Subjected to Seismic Loads
NASA Astrophysics Data System (ADS)
Zameeruddin, Mohd.; Sangle, Keshav K.
2017-06-01
Ten storied-3 bays reinforced concrete bare frame designed for gravity loads following the guidelines of IS 456 and IS 13920 for ductility is subjected to seismic loads. The seismic demands on this building were calculated by following IS 1893 for response spectra of 5% damping (for hard soil type). Plastic hinges were assigned to the beam and column at both ends to represent the failure mode, when member yields. Non-linear static (pushover) analysis was performed to evaluate the performance of the building in reference to first (ATC 40), second (FEMA 356) and next-generation (FEMA 440) performance based seismic design procedures. Base shear against top displacement curve of structure, known as pushover curve was obtained for two actions of plastic hinge behavior, force-controlled (brittle) and deformation-controlled (ductile) actions. Lateral deformation corresponding to performance point proves the building capability to sustain a certain level of seismic loads. The failure is represented by a sequence of formation of plastic hinges. Deformation-controlled action of hinges showed that building behaves like strong-column-weak-beam mechanism, whereas force-controlled action showed formation of hinges in the column. The study aims to understand the first, second and next generation performance based design procedure in prediction of actual building responses and their conservatism into the acceptance criteria.
Thibault-Gagnon, Stéphanie; McLean, Linda; Goldfinger, Corrie; Pukall, Caroline; Chamberlain, Susan
2016-02-01
Pelvic floor muscle (PFM) involvement is suspected in the pathophysiology of provoked vestibulodynia (PVD); however, the underlying mechanisms are unclear. PFM morphology can be inferred from the biometry of the levator hiatus determined through dynamic ultrasound imaging. The aim of this study was to determine the nature of PFM involvement in women with PVD via an evaluation of the biometry of the levator hiatus at rest, upon maximal voluntary contraction (MVC) of the PFMs, and upon maximal Valsalva maneuver (MVM). Thirty-eight women with PVD and 39 asymptomatic controls were imaged using 3D transperineal ultrasound. Levator hiatal dimensions (area; left-right [LR] and anteroposterior [AP] diameters) were measured at rest, on MVC, and on MVM. Differences in hiatal dimensions and in relative changes in dimensions from rest to MVC and from rest to MVM were compared between groups using separate 1-way analyses of variance for each measure and task. Analysis of covariance models were used to investigate the impact of levator hiatal dimensions at rest on the relative changes in the levator hiatal dimensions during MVC and MVM. Levator hiatal area, LR, and AP diameters, at rest, on MVC, and on MVM were the main outcome measures. Relative changes in hiatal dimensions were assessed as the percent change in hiatal area, LR diameter, and AP diameter. In comparison with controls, women with PVD had smaller hiatal areas at rest, on MVC, and on MVM, concurrent with smaller LR diameters on MVM. Women with PVD had a significantly smaller change in hiatal area on MVM than controls, but no differences were evident on MVC. In both groups, smaller levator hiatal dimensions at rest were associated with smaller relative decreases in dimensions on MVC and larger relative increases in dimensions on MVM. In comparison to controls, women with PVD appear to have narrower levator hiatus' and less capacity to distend their hiatus on Valsalva. The state of the PFMs at rest appears to significantly influence biometric changes in the PFMs during contraction and Valsalva. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Changes in Sunken Eyes Combined with Blepharoptosis after Levator Resection.
Mawatari, Yuki; Fukushima, Mikiko; Kawaji, Takahiro
2017-12-01
This study aims to report the changes in sunken eyes combined with blepharoptosis after levator resection. Analysis involved 60 eyes from 32 patients with sunken eyes combined with blepharoptosis. Advancement of the levator aponeurosis and the Müller's muscle complex (levator resection) was performed in these patients. Area of upper eyelid sulcus (AES) was defined as the area of the upper eyelid shadow. The digital images were converted to black and white using image-processing software (Adobe Photoshop), and the AES was calculated using ImageJ software. In addition, margin reflex distance, eyebrow height (EBH), and AES were measured before and 3 months after surgery to assess the changes in the eyelids. Preoperative AES was significantly correlated to age ( P < 0.0001; r = 0.8062). Sunken eyes were remarkably improved after levator resection in all patients. Mean margin reflex distance significantly increased, whereas mean EBH and mean AES significantly decreased at 3 months after surgery ( P < 0.0001). The AES change was significantly correlated to the EBH change ( P < 0.0001; r = 0.5184). The principal aim of levator resection is to improve upper eyelid height and visual fields; however, this technique can alter the location of the eyebrow and upper orbital fat. The effects fill the hollowness of the upper eyelid and can remarkably improve sunken eyes.
Jing, Dejun; Ashton-Miller, James A.; DeLancey, John O.L.
2012-01-01
Objectives To develop an improved model representation of the biomechanics of the levator muscles during the second stage of labor and to use a sensitivity analysis to explore the pathomechanics of levator muscle injury. Methods A subject-specific finite element model of human pelvic floor and fetal head was developed based on in vivo MRI data of a fetal head and maternal pelvis. An anisotropic visco-hyperelastic constitutive model employed material parameters estimated from biaxial tests on pelvic floor tissues. Boundary conditions reflected both anatomic constraints and the curve of Carus. A short second stage of labor, scaled to 10 minutes, was then simulated using a single expulsive push made in the absence of levator co-contraction. Results Large levator stresses occured near the levator hiatus reaching 9 MPa at the pubovisceral muscle enthesis. The dominant principal stresses were located at, and aligned with, the edge of the hiatus. Muscle stretch bordering the levator hiatus was inhomogeneous: The average levator was 3.55 with a high of 4.64 at the pubovisceral muscle enthesis. Decreasing perineal body stiffness by 40%, 50%, and 60% led to reductions in the maximum principal stretch ratio at the pubovisceral muscle enthesis of 8%, 13%, and 18%, respectively. Conclusions The pubovisceral muscle enthesis and the muscle near the perineal body are the regions of greatest strain thereby placing them at highest risk for stretch-related injury. Decreasing perineal body tissue stiffness significantly reduced tissue stress and strain, and therefore injury risk, in those regions. PMID:22209507
In vivo evidence of significant levator ani muscle stretch on MR images of a live childbirth.
Sindhwani, Nikhil; Bamberg, Christian; Famaey, Nele; Callewaert, Geertje; Dudenhausen, Joachim W; Teichgräber, Ulf; Deprest, Jan
2017-08-01
Vaginal childbirth is believed to be a significant risk factor for the development of pelvic floor dysfunction later in life. Previous studies have explored the use of medical imaging and simulations of childbirth to determine the stretch in the levator ani muscle. A report in 2012 has recorded magnetic resonance images of a live childbirth of a 24 year old woman giving birth vaginally for the second time, using a 1.0 Tesla open, high-field scanner. Our objective was to determine the stretch ratios in the levator muscle using these magnetic resonance images of live childbirth. Three-dimensional magnetic resonance image sequences were obtained to visualize coronal and axial planes before and after the childbirth. These images were obtained before the expulsion phase without pushing and were used to reconstruct the levator muscle and the fetal head in 3 dimensions. The fetal head was approximated to be an ellipsoid, and it is assumed that its middle section is visible in dynamic magnetic resonance images. Assuming incompressibility, the full deformation field of the fetal head is then calculated. Real-time cine magnetic resonance images were acquired for the during the expulsion phase, occurring over 2 contractions in the midsagittal plane. The levator muscle stretch is estimated using a custom program. The program calculates points of contact between the fetal head ellipsoid and the levator ani muscle model as the head descends down the birth canal and moves them orthogonal to its surface. Circumferential stretch was calculated to represent the extension needed to allow the passage of the fetal head. Starting from a position in the preexpulsion phase, the levator muscle experiences a maximum circumferential stretch of 248% on the posterior-medial portion of the levator ani muscle, as shown in previously published finite element simulations. However, the maximal stretch was notably less than that predicted by finite element models. This is because our baseline 3-dimensional model of the levator muscle is created from images taken shortly before expulsion and thus is already in a stretched state. Furthermore, the finite element models are created from images of a healthy nulliparous woman, while this study uses images from a para 2 woman. This study is the first attempt to estimate the stretch in levator ani muscle using magnetic resonance images of a live childbirth. The stretch was significant and the locations corroborate with previous findings of finite element models. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Nielsen, Jack N; Kaattari, George E; Drake, William C
1952-01-01
A simple method is presented for estimating lift, pitching-moment, and hinge-moment characteristics of all-movable wings in the presence of a body as well as the characteristics of wing-body combinations employing such wings. In general, good agreement between the method and experiment was obtained for the lift and pitching moment of the entire wing-body combination and for the lift of the wing in the presence of the body. The method is valid for moderate angles of attack, wing deflection angles, and width of gap between wing and body. The method of estimating hinge moment was not considered sufficiently accurate for triangular all-movable wings. An alternate procedure is proposed based on the experimental moment characteristics of the wing alone. Further theoretical and experimental work is required to substantiate fully the proposed procedure.
El-Shazly, Mohamed
2012-11-01
No definitive procedure for cleft repair has been identified yet as the gold standard. Accordingly, this work tried to appraise the hypothesis that if the bony detachment and full retropositioning of the levator veli palatini muscle can ideally present an anatomical C-shape muscular sling restoration and if this is accompanied with pushback palatoplasty, would this present a better result in terms of tissue fistulation and phonetic impairment? A series of 74 different degrees of palatal clefts were operated by pushback palatoplasty combined with a modified approach of the levator vili palatini. This muscle was dissected only from the oral mucosa while kept attached to the nasal one as a musculo-nasomucosal unit. This unit was completely detached from the bony margin of the hard palate and then medially rotated and retropositioned in a typical C-shape mobile sling. Evaluations included suture line assessment and fistula development, and following the child's need for speech therapy. There were no intraoperative complications. Definite anterior fistulae with nasal air and foot leakage were observed in 2 cases. Four cases had postoperative velopharyngeal incompetence with a need for speech therapy. Tension-free closure, lower risk of fistula, good restoration of velopharyngeal functions, ability to be performed on all cleft types, ability to provide a good intraoperative exposure, and being a single stage seem to be the most important advantages of this unpublished technique.
Fabrication and Assembly of High-Precision Hinge and Latch Joints for Deployable Optical Instruments
NASA Technical Reports Server (NTRS)
Phelps, James E.
1999-01-01
Descriptions are presented of high-precision hinge and latch joints that have been co-developed, for application to deployable optical instruments, by NASA Langley Research Center and Nyma/ADF. Page-sized versions of engineering drawings are included in two appendices to describe all mechanical components of both joints. Procedures for assembling the mechanical components of both joints are also presented. The information herein is intended to facilitate the fabrication and assembly of the high-precision hinge and latch joints, and enable the incorporation of these joints into the design of deployable optical instrument systems.
Measurement the thickness of the transverse abdominal muscle in different tasks.
Pang, Ling; Yin, Liquan; Tajiri, Kimiko; Huo, Ming; Maruyama, Hitoshi
2017-02-01
[Purpose] This study examined the measurement of the thickness of the transverse abdominal muscle in different tasks. [Subjects and Methods] The subjects were eleven healthy adult females. Thicknesses of transverse abdominal muscle were measured in seven tasks in the supine position. The tasks were: 1) Resting state, 2) Maximal contraction of transverse abdominal muscle, 3) Maximal contraction of levator ani muscle, 4) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle, 5) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle with front side resistance added to both knee, 6) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle with diagonal resistance added to both knees, and 7) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle with lateral resistance added to both knees. [Results] The thicknesses of transverse abdominal muscle during maximal simultaneous contraction and maximal simultaneous contraction with resistance were greater than during the resting state. [Conclusion] The muscle output during simultaneous contraction and resistance movement were larger than that of each individual muscle.
[Anatomy of the levator ani muscle and implications for obstetrics and gynaecology].
Nyangoh Timoh, K; Bessede, T; Zaitouna, M; Peschaud, F; Chevallier, J-M; Fauconnier, A; Benoit, G; Moszkowicz, D
2015-01-01
Pelvic floor disorders include urogenital and anorectal prolapse, urinary and faecal incontinence. These diseases affect 25% of patients. Most of time, treatment is primarily surgical with a high post-operative risk of recurrence, especially for pelvic organ prolapse. Vaginal delivery is the major risk factor for pelvic floor disorders through levator ani muscle injury or nerve damage. After vaginal delivery, 20% of patients experiment elevator ani trauma. These injuries are more common in case of instrumental delivery by forceps, prolonged second phase labor, increased neonatal head circumference and associated anal sphincter injuries. Moreover, 25% of patients have temporary perineal neuropathy. Recently, pelvic three-dimensional reconstructions from RMI data allowed a better understanding of detailed levator ani muscle morphology and gave birth to a clear new nomenclature describing this muscle complex to be developed. Radiologic and anatomic studies have allowed exploring levator ani innervation leading to speculate on the muscle and nerve damage mechanisms during delivery. We then reviewed the levator ani muscle anatomy and innervation to better understand pelvic floor dysfunction observed after vaginal delivery. Copyright © 2015. Published by Elsevier SAS.
Pertinent anatomy and analysis for midface volumizing procedures.
Surek, Christopher C; Beut, Javier; Stephens, Robert; Jelks, Glenn; Lamb, Jerome
2015-05-01
The study was conducted to construct an anatomically inspired midfacial analysis facilitating safe, accurate, and dynamic nonsurgical rejuvenation. Emphasis is placed on determining injection target areas and adverse event zones. Twelve hemifacial fresh cadavers were dissected in a layered fashion. Dimensional measurements between the midfacial fat compartments, prezygomatic space, mimetic muscles, and neurovascular bundles were used to develop a topographic analysis for clinical injections. A longitudinal line from the base of the alar crease to the medial edge of the levator anguli oris muscle (1.9 cm), lateral edge of the levator anguli oris muscle (2.6 cm), and zygomaticus major muscle (4.6 cm) partitions the cheek into two aesthetic regions. A six-step facial analysis outlines three target zones and two adverse event zones and triangulates the point of maximum cheek projection. The lower adverse event zone yields an anatomical explanation to inadvertent jowling during anterior cheek injection. The upper adverse event zone localizes the palpebral branch of the infraorbital artery. The medial malar target area isolates quadrants for anterior cheek projection and tear trough effacement. The middle malar target area addresses lid-cheek blending and superficial compartment turgor. The lateral malar target area highlights lateral cheek projection and locates the prezygomatic space. This stepwise analysis illustrates target areas and adverse event zones to achieve midfacial support, contour, and profile in the repose position and simultaneous molding of a natural shape during animation. This reproducible method can be used both procedurally and in record-keeping for midface volumizing procedures.
Speksnijder, L; Oom, D M J; Koning, A H J; Biesmeijer, C S; Steegers, E A P; Steensma, A B
2016-08-01
Imaging of the levator ani hiatus provides valuable information for the diagnosis and follow-up of patients with pelvic organ prolapse (POP). This study compared measurements of levator ani hiatal volume during rest and on maximum Valsalva, obtained using conventional three-dimensional (3D) translabial ultrasound and virtual reality imaging. Our objectives were to establish their agreement and reliability, and their relationship with prolapse symptoms and POP quantification (POP-Q) stage. One hundred women with an intact levator ani were selected from our tertiary clinic database. Information on clinical symptoms were obtained using standardized questionnaires. Ultrasound datasets were analyzed using a rendered volume with a slice thickness of 1.5 cm, at the level of minimal hiatal dimensions, during rest and on maximum Valsalva. The levator area (in cm(2) ) was measured and multiplied by 1.5 to obtain the levator ani hiatal volume (in cm(3) ) on conventional 3D ultrasound. Levator ani hiatal volume (in cm(3) ) was measured semi-automatically by virtual reality imaging using a segmentation algorithm. Twenty patients were chosen randomly to analyze intra- and interobserver agreement. The mean difference between levator hiatal volume measurements on 3D ultrasound and by virtual reality was 1.52 cm(3) (95% CI, 1.00-2.04 cm(3) ) at rest and 1.16 cm(3) (95% CI, 0.56-1.76 cm(3) ) during maximum Valsalva (P < 0.001). Both intra- and interobserver intraclass correlation coefficients were ≥ 0.96 for conventional 3D ultrasound and > 0.99 for virtual reality. Patients with prolapse symptoms or POP-Q Stage ≥ 2 had significantly larger hiatal measurements than those without symptoms or POP-Q Stage < 2. Levator ani hiatal volume at rest and on maximum Valsalva is significantly smaller when using virtual reality compared with conventional 3D ultrasound; however, this difference does not seem clinically important. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Kim, Jinyong; Betschart, Cornelia; Ramanah, Rajeev; Ashton-Miller, James A; DeLancey, John O L
2015-11-01
The levator ani muscle (LA) injury associated with vaginal birth occurs in a characteristic site of injury on the inner surface of the pubic bone to the pubovisceral portion of the levator ani muscle's origin. This study investigated the gross and microscopic anatomy of the pubic origin of the LA in this region. Pubic origin of the levator ani muscle was examined in situ then harvested from nine female cadavers (35-98 years). A combination of targeted feature sampling and sequential sampling was used where each specimen was cut sequentially in approximately 5 mm thick slices apart in the area of known LA injury. Histological sections were stained with Masson's trichrome. The pubovisceral origin is transparent and thin as it attaches tangentially to the pubic periosteum, with its morphology changing from medial to lateral regions. Medially, fibers of the thick muscle belly coalesce toward multiple narrow points of bony attachment for individual fascicles. In the central portion there is an aponeurosis and the distance between muscle and periosteum is wider (∼3 mm) than in the medial region. Laterally, the LA fibers attach to the levator arch where the transition from pubovisceral muscle to the iliococcygeal muscle occurs. The morphology of the levator ani origin varies from the medial to lateral margin. The medial origin is a rather direct attachment of the muscle, while lateral origin is made through the levator arch. © 2014 Wiley Periodicals, Inc.
Levator Ani Muscle Stretch Induced by Simulated Vaginal Birth
Lien, Kuo-Cheng; Mooney, Brian; DeLancey, John O. L.; Ashton-Miller, James A.
2005-01-01
OBJECTIVE: To develop a three-dimensional computer model to predict levator ani muscle stretch during vaginal birth. METHODS: Serial magnetic resonance images from a healthy nulliparous 34-year-old woman, published anatomic data, and engineering graphics software were used to construct a structural model of the levator ani muscles along with related passive tissues. The model was used to quantify pelvic floor muscle stretch induced during the second stage of labor as a model fetal head progressively engaged and then stretched the iliococcygeus, pubococcygeus, and puborectalis muscles. RESULTS: The largest tissue strain reached a stretch ratio (tissue length under stretch/original tissue length) of 3.26 in medial pubococcygeus muscle, the shortest, most medial and ventral levator ani muscle. Regions of the ileococcygeus, pubococcygeus, and puborectalis muscles reached maximal stretch ratios of 2.73, 2.50, and 2.28, respectively. Tissue stretch ratios were proportional to fetal head size: For example, increasing fetal head diameter by 9% increased medial pubococcygeus stretch by the same amount. CONCLUSION: The medial pubococcygeus muscles undergo the largest stretch of any levator ani muscles during vaginal birth. They are therefore at the greatest risk for stretch-related injury. PMID:14704241
Ptosis induced by topical steroid eye drops: Two cases reports.
Zhu, Yanan; Sun, Chaohui; Zhang, Xin; Shentu, Xingchao
2017-12-01
Ptosis is a rare complication of periocular steroid use. Studies report that local injections of steroids produce ptosis. We describe the first 2 cases of ptosis because of long-term treatment with topical steroid eye drops. Two cases admitted to our hospital because of ptosis of their right eye after long-term treatment with topical steroid eye drops. Both of them had uncontrolled Posner-Schlossman syndrome. Two cases were diagnosed as steroid-related ptosis. Regulatory anti-inflammation therapy was prescribed for case 1, and after inflammation control, phacoemulsification was done for her. Six months after steroid withdrawal, the levator resection of the right eye was performed. Case 2 refused our advice of steroid reduction and ptosis surgery. After surgery, case 1 retained a symmetrical appearance during a 1-year follow-up. In the surgery, we found thin levator muscles and slack levator palpebrae superioris aponeurosis (LPSA) in the affected eye. Postoperative transmission electron microscopy revealed typical signs of apoptosis in levator muscle cells. We suggest topical application of steroids induces levator muscle apoptosis and LPSA weakness, and results in ptosis. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Predictive images of postoperative levator resection outcome using image processing software.
Mawatari, Yuki; Fukushima, Mikiko
2016-01-01
This study aims to evaluate the efficacy of processed images to predict postoperative appearance following levator resection. Analysis involved 109 eyes from 65 patients with blepharoptosis who underwent advancement of levator aponeurosis and Müller's muscle complex (levator resection). Predictive images were prepared from preoperative photographs using the image processing software (Adobe Photoshop ® ). Images of selected eyes were digitally enlarged in an appropriate manner and shown to patients prior to surgery. Approximately 1 month postoperatively, we surveyed our patients using questionnaires. Fifty-six patients (89.2%) were satisfied with their postoperative appearances, and 55 patients (84.8%) positively responded to the usefulness of processed images to predict postoperative appearance. Showing processed images that predict postoperative appearance to patients prior to blepharoptosis surgery can be useful for those patients concerned with their postoperative appearance. This approach may serve as a useful tool to simulate blepharoptosis surgery.
Predictive images of postoperative levator resection outcome using image processing software
Mawatari, Yuki; Fukushima, Mikiko
2016-01-01
Purpose This study aims to evaluate the efficacy of processed images to predict postoperative appearance following levator resection. Methods Analysis involved 109 eyes from 65 patients with blepharoptosis who underwent advancement of levator aponeurosis and Müller’s muscle complex (levator resection). Predictive images were prepared from preoperative photographs using the image processing software (Adobe Photoshop®). Images of selected eyes were digitally enlarged in an appropriate manner and shown to patients prior to surgery. Results Approximately 1 month postoperatively, we surveyed our patients using questionnaires. Fifty-six patients (89.2%) were satisfied with their postoperative appearances, and 55 patients (84.8%) positively responded to the usefulness of processed images to predict postoperative appearance. Conclusion Showing processed images that predict postoperative appearance to patients prior to blepharoptosis surgery can be useful for those patients concerned with their postoperative appearance. This approach may serve as a useful tool to simulate blepharoptosis surgery. PMID:27757008
Chen, Philip Kuo-Ting; Por, Yong-Chen; Liou, Eric Jein-Wein; Chang, Frank Chun-Shin
2015-05-01
Le Fort I maxillary distraction with the rigid external distraction (RED) device is performed to correct severe midface retrusion in cleft patients, but it may adversely affect velopharyngeal function. This study aims to investigate the angular changes in the levator veli palatini (LVP) and its influence on velopharyngeal function after maxillary distraction using 3-dimensional computed tomography (3D CT) scan volume rendered images. This was a retrospective study of 12 patients. Group 1 had no velopharyngeal function deterioration and group 2 had velopharyngeal function deterioration. Preoperative and 1 year postoperative CT scans were analyzed with Mimics v10 software. Segmentation of the LVP and the nasopharyngeal airway was performed and volumetric images were obtained. Six measurements were made: (1) the angle between the levator plane and the Frankfort horizontal, (2) the angle between the levator plane and the soft palate plane, (3) the angle between the 2 LVP muscles, (4) the pharyngeal depth, and (5, 6) the movement of the inferior pharyngeal point with respect to the horizontal and vertical planes. The independent samples t test, Mann-Whitney test, and paired t tests were used for statistical analyses (P < 0.05). Group 2 had statistically significant reduction in the angle between the levator plane and Frankfort horizontal as well as the soft palate plane. Group 1 had a statistically significant increase in the pharyngeal depth and movement of the inferior pharyngeal point with respect to the horizontal plane. A decrease in the angle between the levator plane and the Frankfort horizontal or the soft palate plane was associated with velopharyngeal function deterioration.
Chen, Wei; Wn, Lijun; Yan, Zhihan; Wang, Jusong; Fu, Yalan; Chen, Xiongfei; Liu, Kun; Wu, Zhipeng
2011-10-01
This paper is to establish a three-dimensional finite element model (3D-FEM) of pelvic floor levator ani muscles in an old healthy women. We acquired the image data of the pelvic bones and pelvic floor muscles from CT and MRI scanning in a non-pregnant old healthy female volunteers. The 3-D reconstruction and mesh optimization of the whole pelvic bones and muscles with application of image processing software Mimics12.0 and Geomagic9.0 were obtained. Then we built the 3D-FEM of the musculoskeletal system of the pelvic bones and levator ani muscles with Ansys11.0 software. We obtained an accurate 3D-FEM of pelvic bones and levator ani muscles in the older healthy woman. The results showed that it was reliable to build 3D-FEM with CT and MRI scanning data and this model could vividly reflect the huge space anatomy of the real pelvic floor levator ani muscles. It avoids the defects to gain the model from the body of anatomical specimens in the past. The image data of model are closer to vivisection, and the model is more conducive to the latter finite element analysis.
Chaudhary, Priti; Singh, Zora; Khullar, Meenakshi; Arora, Kamal
2013-01-01
Amongst the endocrine glands, thyroid gland is well known for its developmental anomalies, which range from common to rare ones. The presence of levator glandulae thyroideae and its anatomical variations gain importance in the pathologies which are related to thyroid gland and their treatment modalities. Levator glandulae thyroideae is a fibromuscular band. If it is present, it is usually seen on the left side, to connect the pyramidal lobe of thyroid gland and the hyoid bone. But levator glandulae thyroideae which stretches from isthmus to the body of hyoid bone is rare and only very few cases have been reported in the medical literature. During a routine dissection of the thyroid gland in a 55 years old male cadaver, a Levator Glandulae Thyroideae (which was fibromusculoglandular in nature) was seen, with the absence of pyramidal lobe on the left side. It directly came from upper border of isthmus and went upto hyoid bone. It also had innervation from branches of external laryngeal nerve. This was also associated with absence of superior thyroid artery on the same side. The knowledge on various developmental anomalies of the gland and variations in neurovascular relations will help the surgeons in plan thyroid surgeries in a better and safe way. PMID:23998080
Hoyte, L; Ratiu, P
2001-09-01
Magnetic resonance imaging techniques have improved the study of female pelvic dysfunction. However, disagreements between magnetic resonance measurements and their derived 3-dimensional reconstructions were noted. We tested the hypothesis that these discrepancies stemmed from variations in magnetic resonance acquisition angle. Images from the pelvis of the Visible Human Female (a thinly sliced cadaveric image data set) were obtained. Slices in the axial plane were rotated around pivot points in the pelvis to yield a set of similar-appearing para-axial images. A parameter that described the maximum anterior-posterior dimension of the levator hiatus was defined. This levator hiatus parameter was measured on all of the rotated images and compared with an expected value that was calculated from trigonometry. The levator hiatus was also measured on a group of similar-appearing slices rotated slightly around a defined point. In 1 group of slices, expected levator hiatus variation was 1.5 to 6.1%, whereas measured variation was 4% to 15%. Among the similar-appearing rotated slices, 4.8% to 16.0% variations were seen in the levator hiatus. Identical measurements made on radiologic images can vary widely. Slice acquisition must be standardized to avoid errors in data comparison.
Ultrasound imaging of the pelvic floor: changes in anatomy during and after first pregnancy.
van Veelen, G A; Schweitzer, K J; van der Vaart, C H
2014-10-01
To describe changes in the absolute values of levator hiatal dimensions and in the contractility and distensibility of the levator hiatus during pelvic floor contraction and Valsalva maneuver, using three/four-dimensional (3D/4D) transperineal ultrasound in women during and after their first pregnancy. Two-hundred and eighty nulliparous pregnant women underwent ultrasound examination at 12 and 36 weeks' gestation and 6 months postpartum. Hiatal dimensions were measured at rest, on pelvic floor contraction and on Valsalva maneuver. The contractility and distensibility were determined by the difference between hiatal dimensions at rest and those on contraction or Valsalva, respectively. After exclusions, there were 231 datasets from women at rest, 199 for pelvic floor contraction and 230 for Valsalva maneuver. Data at 36 weeks' gestation and 6 months postpartum were compared with data at 12 weeks' gestation. At 36 weeks' gestation, the absolute values of hiatal dimensions and the contractility and distensibility of the levator hiatus were significantly increased compared with those at 12 weeks' gestation. Women who delivered vaginally showed a persistent significant increase in hiatal dimensions on Valsalva, whereas women who delivered by prelabor or first-stage Cesarean section showed no significant changes in hiatal dimensions on Valsalva. After both vaginal and Cesarean section delivery, there was a persistent increase in the distensibility of the hiatus during Valsalva compared with in early pregnancy. During first pregnancy, the absolute values of levator hiatal dimensions and the contractility and distensibility of the levator hiatus increase. Regardless of delivery mode, increased distensibility of the levator hiatus during Valsalva persists after childbirth. This increased pelvic floor distensibility may play a role in the development of pelvic floor dysfunction in later life. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Vergeldt, T F M; Notten, K J B; Stoker, J; Fütterer, J J; Beets-Tan, R G; Vliegen, R F A; Schweitzer, K J; Mulder, F E M; van Kuijk, S M J; Roovers, J P W R; Kluivers, K B; Weemhoff, M
2016-05-01
To compare translabial three-dimensional (3D) ultrasound with magnetic resonance imaging (MRI) for the measurement of levator hiatal biometry at rest in women with pelvic organ prolapse, and to determine the interobserver reliability between two independent observers for ultrasound and MRI measurements. Data were derived from a multicenter prospective cohort study in which women scheduled for conventional anterior colporrhaphy underwent translabial 3D ultrasound and MRI prior to surgery. Intraclass correlation coefficients (ICCs) were calculated to estimate interobserver reliability between two independent observers and determine the agreement between ultrasound and MRI measurements. Bland-Altman plots were created to assess the agreement between ultrasound and MRI measurements. Data from 139 women from nine hospitals were included in the study. The interobserver reliability of ultrasound assessment at rest, during Valsalva maneuver and during contraction and of MRI assessment at rest were moderate or good. The agreement between ultrasound and MRI for the measurement of levator hiatal biometry at rest was moderate, with ICCs of 0.52 (95%CI, 0.32-0.66) for levator hiatal area, 0.44 (95%CI, 0.21-0.60) for anteroposterior diameter and 0.44 (95%CI, 0.22-0.60) for transverse diameter. Levator hiatal biometry measurements were statistically significantly larger on MRI than on translabial 3D ultrasound. The agreement between translabial 3D ultrasound and MRI for measurement of the levator hiatus at rest in women with pelvic organ prolapse was only moderate. The results of translabial 3D ultrasound and MRI should therefore not be used interchangeably in daily practice or in clinical research. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Yoshida, Mikako; Murayama, Ryoko; Haruna, Megumi; Matsuzaki, Masayo; Yoshimura, Kenichi; Murashima, Sachiyo; Kozuma, Shiro
2013-04-01
To compare the pelvic floor function between women with and without stress urinary incontinence after vaginal delivery. Seventeen women (age 35.5 ± 3.5) were prospectively studied at about 6 weeks, 3 months, and 6 months after vaginal delivery. Urinary incontinence was assessed by the International Consultation on Incontinence Questionnaire - Short Form. Pelvic floor function was assessed by antero-posterior diameter of the levator hiatus using transperineal ultrasound. Five of 17 women experienced postpartum stress urinary incontinence. The antero-posterior diameter of the levator hiatus at rest was significantly longer in stress urinary incontinent women than in continent women until 3 months after delivery (p < 0.01), though shortening of the antero-posterior diameter of the levator hiatus was not significantly different between continent women and stress urinary incontinent women. Regardless of urinary incontinence, the antero-posterior diameter of the levator hiatus at rest shortened at 6 months postpartum, compared to 6 weeks postpartum (p < 0.001). The antero-posterior diameter of the levator hiatus during contraction had shortened only in continent women by 6 months postpartum (p = 0.02). The extended pelvic floor may be a cause of stress urinary incontinence in the postpartum period. Therefore, treatment to improve the extended pelvic floor should be developed for the prevention of stress urinary incontinence.
Zheng, Yi; Han, Jia-Gang; Wang, Zhen-Jun; Gao, Zhi-Gang; Wei, Guang-Hui; Zhai, Zhi-Wei; Zhao, Bao-Cheng
2018-06-05
The introduction of individualized abdominoperineal excision (APE) may minimize operative trauma and reduce the rate of complications. The purpose of this study was to evaluate the safety and efficacy of individualized APE for low rectal cancer. Fifty-six patients who underwent individualized APE from June 2011 to June 2015 were evaluated retrospectively in Beijing Chaoyang Hospital, Capital Medical University. The main outcome measures were circumferential resection margin (CRM) involvement, intraoperative perforation, postoperative complications, and local recurrence. Statistical analysis was performed using SPSS version 16.0. Fifty (89%) patients received preoperative chemoradiotherapy: 51 (91%) patients were treated with the sacrococcyx preserved; 27 (48%) patients with the levator ani muscle partially preserved bilaterally; 20 (36%) patients with the levator ani muscle partially preserved unilaterally and the muscle on the opposite side totally preserved; 7 (13%) patients with intact levator ani muscle and part of the ischioanal fat bilaterally dissected; and 2 (4%) patients with part of the ischioanal fat and intact lavator ani muscle dissected unilaterally and the muscle on the opposite side partially preserved. The most common complications included sexual dysfunction (12%), perineal wound complications (13%), urinary retention (7%), and chronic perineal pain (5%). A positive CRM was demonstrated in 3 (5%) patients, and intraoperative perforations occurred in 2 (4%) patients. On multiple logistic regression analysis, longer operative time (P = 0.032) and more intraoperative blood loss (P = 0.006) were significantly associated with perineal procedure-related complications. The local recurrence was 4% at a median follow-up of 53 months (range: 30-74 months). With preoperative chemoradiotherapy, individualized APE may be a relatively safe and feasible approach for low rectal cancer with acceptable oncological outcomes.
Three-Dimensional Magnetic Resonance Imaging of Velopharyngeal Structures
ERIC Educational Resources Information Center
Bae, Youkyung; Kuehn, David P.; Sutton, Bradley P.; Conway, Charles A.; Perry, Jamie L.
2011-01-01
Purpose: To report the feasibility of using a 3-dimensional (3D) magnetic resonance imaging (MRI) protocol for examining velopharyngeal structures. Using collected 3D MRI data, the authors investigated the effect of sex on the midsagittal velopharyngeal structures and the levator veli palatini (levator) muscle configurations. Method: Ten Caucasian…
[Treatment of eyelid retraction in Grave's disease by recession of the levator complex].
Fichter, N; Schittkowski, M; Guthoff, R F
2004-11-01
The chronic stage in Grave's orbitopathy is characterised by fibrotic changes within the orbital soft tissues, especially the extraocular muscles. Retraction of the eyelids is a common clinical feature of this phenomenon. To solve this problem several techniques for lengthening the upper eyelid have been described with variable rates of success. In this report we describe our modified Harvey's technique for the correction of upper eyelid retraction which includes a complete recession of the Muller's muscle/levator complex from the tarsal plate without the interposition of a spacer. Finally only the skin and the superficial orbicularis muscle are sutured. We also report about our results with this procedure. 8 patients (1 male, 7 female) with lid retraction in Grave's ophthalmopathy were recorded who had undergone the modified lengthening technique by an external approach between 2001 and 2004. Four patients underwent a bilateral procedure and 1 patient showed a significant under-correction, necessitating reoperation. So a total of 13 procedures were included in this follow-up study. Beside the common ophthalmological examination, special interest was put in the difference of the two eyelid apertures in primary position pre- and postoperatively. Within a follow-up period of at least 3 months we recorded an averaged lengthening of the upper eyelid of 3.1 mm. The difference of the two eyelid apertures in primary position improved from 2.2 mm preoperatively to 1.0 mm postoperatively. Only 1 patient needed reoperation because of a significant under-correction. There were no late over-corrections observed. The modified Harvey's technique to lengthen the upper eyelid is a safe and effective method to reduce upper eyelid retraction in Grave's disease. An eventually required orbital decompression or extraocular muscle surgery has to be done before the lid surgery.
[Dynamic study of the female levator ani muscle using MRI 3D vectorial modeling].
Delmas, Vincent; Ami, Olivier; Iba-Zizen, Marie-Thérèse
2010-06-01
The levator ani muscle has a major role in the female pelvic floor, and is involved in the pathophysiology of pelvic prolapse and stress urinary incontinence. We conducted an anatomical and morphological study of this muscle using dynamic 3D vectorial reconstruction MRI, in order to analyze the contraction of two major components of the levator ani: the iliococcygeus and pubococcygeus. Three volunteer healthy continent nulliparous women aged from 19 to 22 underwent dynamic pelvic MRI. Coronal T2-weighted pelvic images were obtained in the supine position, at rest, holding back, and during Valsalva stress effort. 3D vectorial models were reconstructed by manual segmentation of the source images, and were set up on bony anatomic marks. Iliococcygeus and pubococcygeus volumes were measured in the three positions. Volumetrics, displacement and dynamic morphing changes were analyzed with 3D vectorial animation software. The urogenital hiatus extended more holding back (mean +4.31 mm) than on effort (mean +2.78 mm). The iliococcygeus lowered (mean -3.95 mm) and deviated outward (mean +3.01 mm). The basic tone of the iliococcygeus muscle gives it a dome shape, and its reflex contraction against abdominal strain ensures anal and urinary continence The levator ani is more than a pelvic diaphragm: it is a truly dynamic pelvic floor. Its points of support on the stiff osseous frame allow it to retain the pelvic organs. The levator ani muscle seems to prevent anal prolapse during stress strain.
Hwang, Kun
2012-03-01
The author created an innovative method of W-pushback and levator repositioning without having to make an incision to the nasal mucosa for submucous cleft palate repair.The W-shaped mucoperiosteal flap is outlined where the 2 peaks of W are the alveolar processes of both canine teeth and the midpoint of W is the anterior limit of the cleft notch of the hard palate. A short incision, medial to and behind the maxillary tuberosity and curved forward onto the palate and extended forward just medial to the alveolar process, is joined by a second incision from the apex of the cleft to the region of the canine tooth. The W-shaped mucoperiosteal flap is raised until the midline notch of the hard palate is exposed. The nasal mucosa and abnormally inserted levator veli palatini muscle to the posterior border of the hard palate bone are detached. By leaving the nasal mucosa intact, the detached levator veli palatini muscle is approximated at the midline and so the zona pellucida is obliterated. The cleft uvulas are cut in half and closed. The approximated W-flap is joined to the small anterior flap by 1 or more sutures (the W-pushback).Three patients were operated on with this technique without serious complications.The author believes that this method can make the levator sling and increase the length of the soft palate without making an incision to the nasal mucosa.
Progressive collapse of a two-story reinforced concrete frame with embedded smart aggregates
NASA Astrophysics Data System (ADS)
Laskar, Arghadeep; Gu, Haichang; Mo, Y. L.; Song, Gangbing
2009-07-01
This paper reports the experimental and analytical results of a two-story reinforced concrete frame instrumented with innovative piezoceramic-based smart aggregates (SAs) and subjected to a monotonic lateral load up to failure. A finite element model of the frame is developed and analyzed using a computer program called Open system for earthquake engineering simulation (OpenSees). The finite element analysis (FEA) is used to predict the load-deformation curve as well as the development of plastic hinges in the frame. The load-deformation curve predicted from FEA matched well with the experimental results. The sequence of development of plastic hinges in the frame is also studied from the FEA results. The locations of the plastic hinges, as obtained from the analysis, were similar to those observed during the experiment. An SA-based approach is also proposed to evaluate the health status of the concrete frame and identify the development of plastic hinges during the loading procedure. The results of the FEA are used to validate the SA-based approach for detecting the locations and occurrence of the plastic hinges leading to the progressive collapse of the frame. The locations and sequential development of the plastic hinges obtained from the SA-based approach corresponds well with the FEA results. The proposed SA-based approach, thus validated using FEA and experimental results, has a great potential to be applied in the health monitoring of large-scale civil infrastructures.
Pai, Vishwas D.; Engineer, Reena; Patil, Prachi S.; Arya, Supreeta; Desouza, Ashwin L.
2016-01-01
Background To compare extra levator abdomino perineal resection (ELAPER) with conventional abdominoperineal resection (APER) in terms of short-term oncological and clinical outcomes. Methods This is a retrospective review of a prospectively maintained database including all the patients of rectal cancer who underwent APER at Tata Memorial Center between July 1, 2013, and January 31, 2015. Short-term oncological parameters evaluated included circumferential resection margin involvement (CRM), tumor site perforation, and number of nodes harvested. Peri operative outcomes included blood loss, length of hospital stay, postoperative perineal wound complications, and 30-day mortality. The χ2-test was used to compare the results between the two groups. Results Forty-two cases of ELAPER and 78 cases of conventional APER were included in the study. Levator involvement was significantly higher in the ELAPER compared with the conventional group; otherwise, the two groups were comparable in all the aspects. CRM involvement was seen in seven patients (8.9%) in the conventional group compared with three patients (7.14%) in the ELAPER group. Median hospital stay was significantly longer with ELAPER. The univariate analysis of the factors influencing CRM positivity did not show any significance. Conclusions ELAPER should be the preferred approach for low rectal tumors with involvement of levators. For those cases in which levators are not involved, as shown in preoperative magnetic resonance imaging (MRI), the current evidence is insufficient to recommend ELAPER over conventional APER. This stresses the importance of preoperative MRI in determining the best approach for an individual patient. PMID:27284466
Reconstruction of palatal defect using mucoperiosteal hinge flap and pushback palatoplasty.
Lee, S I; Lee, H S; Hwang, K
2001-11-01
This article describes a simple, new surgical technique to provide a complete two-layer closure of palatal defect resulting from a surgical complication of trans palatal resection of skull base chordoma. The nasal layer was reconstructed with triangular shape oral mucoperiosteal turn over hinge flap based on anterior margin of palatal defect and rectangular shaped lateral nasal mucosal hinge flaps. The oral layer was reconstructed with conventional pushback V-Y advancement 2-flaps palatoplasty. Each layer of the flaps were secured with two key mattress suture for flap coaptation. This technique has some advantages: simple, short operation time, one-stage procedure, no need of osteotomy. It can close small- to medium-sized palatal defect of palate or wide cleft palate and can prevent common complication of oronasal fistula, which could be caused by tension.
MRI evaluation of the levator ani muscle: anatomic correlations and practical applications.
Plattner, V; Leborgne, J; Heloury, Y; Cohen, J Y; Rogez, J M; Lehur, P A; Robert, R
1991-01-01
A comparative study of serial anatomic sections in the transverse, frontal and sagittal planes with corresponding MRI sections of the pelvis allowed the authors to define the most suitable sectional planes and MRI modes for a morphologic study of the levator ani muscle. This study shows the value of MRI examination in the assessment of anorectal malformations.
Cytosolic androgen receptor in regenerating rat levator ani muscle.
Max, S R; Mufti, S; Carlson, B M
1981-01-01
The development of the cytosolic androgen receptor was studied after degeneration and regeneration of the rat levator ani muscle after a crush lesion. Muscle regeneration appears to recapitulate myogenesis in many respects. It therefore provides a model tissue in sufficiently in large quantity for investigating the ontogenesis of the androgen receptor. The receptor in the cytosol of the normal levator ani muscle has binding characteristics similar to those of the cytosolic receptor in other androgen-sensitive tissues. By day 3 after a crush lesion of the levator ani muscle, androgen binding decreased to 25% of control values. This decrease was followed by a 4-5 fold increase in hormone binding, which attained control values by day 7 after crush. Androgen binding remained stable at the control value up to day 60 after crushing. These results were correlated with the morphological development of the regenerating muscle after crushing. It is concluded that there is little, if any, androgen receptor present in the early myoblastic stages of regeneration; rather, synthesis of the receptor may occur after the fusion of myoblasts and during the differentiation of myotubes into cross-striated muscle fibres. Images PLATE 1 PLATE 2 PMID:6977357
Anorectal pain and irritation: anal fissure, levator syndrome, proctalgia fugax, and pruritus ani.
Vincent, C
1999-03-01
Anal fissures, proctalgia fugax, levator ani syndrome, and pruritus ani are common causes of anorectal pain and irritation. The clinician who obtains a thorough history and performs a complete examination can accurately diagnose these disorders. Ancillary tests seldom are helpful and rarely are necessary. Most patients suffering from these conditions readily respond to conservative therapy provided in the primary care practitioner's office.
van Veelen, G A; Schweitzer, K J; van der Vaart, C H
2013-11-01
To evaluate the reliability of measurements of the levator hiatus and levator-urethra gap (LUG) using three/four-dimensional (3D/4D) transperineal ultrasound in women during their first pregnancy and 6 months postpartum, and to assess the learning process for these measurements. An inexperienced observer was taught to perform measurements of the levator hiatus and LUG by an experienced observer. After training, 3D/4D ultrasound volume datasets of 40 women in the first trimester were analyzed by these two observers. Another training session then took place and both observers repeated the analyses of the same volume datasets. Finally, analyses of 40 volume datasets of the women 6 months postpartum were performed by both observers. Intra- and interobserver reliability were determined by intraclass correlation coefficients (ICC) with 95% CIs. For levator hiatal measurements, in the women during their first pregnancy the interobserver reliability was substantial to almost perfect after both the first and second training session (ICC, 0.62-0.83 and 0.71-0.89, respectively, for anteroposterior diameter, transverse diameter and area at rest, on contraction and on Valsalva) and the intraobserver reliability was substantial to almost perfect for both observers. For these measurements performed once the women had delivered, interobserver reliability was moderate to almost perfect. For LUG measurements performed during pregnancy, interobserver reliability was slight to moderate after the first training session (ICC, 0.14-0.54), but improved after the second training session (ICC, 0.38-0.71), and intraobserver reliability was moderate to substantial for the experienced observer and slight to moderate for the inexperienced observer. For these measurements performed when the women had delivered, interobserver reliability was fair to moderate. The levator hiatus and LUG can be measured reliably using 3D/4D ultrasound in primigravid and primiparous women. The technique to measure dimensions of the levator hiatus requires limited teaching, but LUG measurements are more difficult and require more extensive training. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
Postpartum pelvic floor muscle training and urinary incontinence: a randomized controlled trial.
Hilde, Gunvor; Stær-Jensen, Jette; Siafarikas, Franziska; Ellström Engh, Marie; Bø, Kari
2013-12-01
To evaluate whether postpartum pelvic floor muscle training decrease prevalence of any urinary incontinence (UI) in primiparous women with and without UI at inclusion (mixed population) and further to perform stratified analyses on women with and without major levator ani muscle defects. A two-armed assessor-blinded randomized controlled trial including primiparous women 6 weeks after vaginal delivery was conducted. Participants were stratified on major levator ani muscle defects, verified by transperineal ultrasonography, and thereafter randomly allocated to training or control. All participants were taught to contract the pelvic floor muscles. The control participants received no further intervention, whereas training participants attended a weekly supervised pelvic floor muscle training class and performed daily home exercise for 16 weeks. Primary outcome was self-reported UI analyzed by relative risk. We included 175 women, 55 with major levator ani muscle defects and 120 without. Prevalence of UI at baseline was 39.1% in the training group (n=87) and 50% among those in the control group (n=88). Fifteen women (8.6%) were lost to follow-up. At 6 months after delivery (postintervention), 34.5% and 38.6% reported UI in the training and control groups, respectively. Relative risk analysis of UI gave a nonsignificant effect size of 0.89 (95% confidence interval [CI] 0.60-1.32). Results were similar for the stratum with and without major levator ani muscle defects, 0.89 (95% CI 0.51-1.56) and 0.90 (95% CI 0.53-1.52), respectively. Postpartum pelvic floor training did not decrease UI prevalence 6 months after delivery in primiparous women. Stratified analysis on women with and without major levator ani muscle defects showed similar nonsignificant results. ClinicalTrials.gov, www.clinicaltrials.gov, NCT01069484. : I.
A Multi-Compartment 3-D Finite Element Model of Rectocele and Its Interaction with Cystocele
Luo, Jiajia; Chen, Luyun; Fenner, Dee E.; Ashton-Miller, James A.; DeLancey, John O. L.
2015-01-01
We developed a subject-specific 3-D finite element model to understand the mechanics underlying formation of female pelvic organ prolapse, specifically a rectocele and its interaction with a cystocele. The model was created from MRI 3-D geometry of a healthy 45 year-old multiparous woman. It included anterior and posterior vaginal walls, levator ani muscle, cardinal and uterosacral ligaments, anterior and posterior arcus tendineus fascia pelvis, arcus tendineus levator ani, perineal body, perineal membrane and anal sphincter. Material properties were mostly from the literature. Tissue impairment was modeled as decreased tissue stiffness based on previous clinical studies. Model equations were solved using Abaqus v 6.11. The sensitivity of anterior and posterior vaginal wall geometry was calculated for different combinations tissue impairments under increasing intraabdominal pressure. Prolapse size was reported as POP-Q point at point Bp for rectocele and point Ba for cystocele. Results show that a rectocele resulted from impairments of the levator ani and posterior compartment support. For 20% levator and 85% posterior support impairments, simulated rectocele size (at POP-Q point: Bp) increased 0.29 mm/cm H2O without apical impairment and 0.36 mm/cm H2O with 60% apical impairment, as intraabdominal pressures increased from 0 to 150 cm H2O. Apical support impairment could result in the development of either a cystocele or rectocele. Simulated repair of posterior compartment support decreased rectocele but increased a preexisting cystocele. We conclude that development of rectocele and cystocele depend on the presence of anterior, posterior, levator and/or or apical support impairments, as well as the interaction of the prolapse with the opposing compartment. PMID:25757664
Goel, Ruchi; Kishore, Divya; Nagpal, Smriti; Jain, Sparshi; Agarwal, Tushar
2017-01-01
Background: Recovery of Bell`s phenomenon after levator resection is unpredicatable. Delayed recovery can result in vision threatening corneal complications. Aim: To study the variability of Bell’s phenomenon and time taken for its recovery following levator resection for blepharoptosis and to correlate it with the amount of resection. Methods: A prospective observational study was conducted on 32 eyes of 32 patients diagnosed as unilateral simple congenital blepharoptosis who underwent levator resection at a tertiary care center between July 2013 and May 2015. Patients were followed up for 5 months and correction of ptosis, type of Bell`s, duration of Bell`s recovery and complications were noted. Results: The study group ranged from 16-25 years with 15:17 male: female ratio. There were 9 mild, 16 moderate and 7 severe ptosis. Satisfactory correction was achieved in all cases. Good Bell`s recovery occurred in 13 eyes on first post-op day, in 2-14 days in 19 eyes and 28 days in 1 eye. Inverse Bell`s was noted along with lid oedema and ecchymosis in 2 patients. Large resections (23-26mm) were associated with poor Bell`s on the first postoperative day (p=0.027, Fisher`s exact test). However, the duration required for recovery of Bell`s phenomenon did not show any significant difference with the amount of resection. (p=0.248, Mann Whitney test). Larger resections resulted in greater lagophthalmos (correlation=0.830, p<0.0001). Patients with recovery of Bell`s delayed for more than 7 days were associated with greater number of complications (p=0.001 Fisher`s Exact Test). Conclusion: Close monitoring for Bell`s recovery is required following levator resection. PMID:28584563
Dietz, Hans Peter; D’hooge, Jan; Barratt, Dean; Deprest, Jan
2018-01-01
Abstract. Segmentation of the levator hiatus in ultrasound allows the extraction of biometrics, which are of importance for pelvic floor disorder assessment. We present a fully automatic method using a convolutional neural network (CNN) to outline the levator hiatus in a two-dimensional image extracted from a three-dimensional ultrasound volume. In particular, our method uses a recently developed scaled exponential linear unit (SELU) as a nonlinear self-normalizing activation function, which for the first time has been applied in medical imaging with CNN. SELU has important advantages such as being parameter-free and mini-batch independent, which may help to overcome memory constraints during training. A dataset with 91 images from 35 patients during Valsalva, contraction, and rest, all labeled by three operators, is used for training and evaluation in a leave-one-patient-out cross validation. Results show a median Dice similarity coefficient of 0.90 with an interquartile range of 0.08, with equivalent performance to the three operators (with a Williams’ index of 1.03), and outperforming a U-Net architecture without the need for batch normalization. We conclude that the proposed fully automatic method achieved equivalent accuracy in segmenting the pelvic floor levator hiatus compared to a previous semiautomatic approach. PMID:29340289
Bonmati, Ester; Hu, Yipeng; Sindhwani, Nikhil; Dietz, Hans Peter; D'hooge, Jan; Barratt, Dean; Deprest, Jan; Vercauteren, Tom
2018-04-01
Segmentation of the levator hiatus in ultrasound allows the extraction of biometrics, which are of importance for pelvic floor disorder assessment. We present a fully automatic method using a convolutional neural network (CNN) to outline the levator hiatus in a two-dimensional image extracted from a three-dimensional ultrasound volume. In particular, our method uses a recently developed scaled exponential linear unit (SELU) as a nonlinear self-normalizing activation function, which for the first time has been applied in medical imaging with CNN. SELU has important advantages such as being parameter-free and mini-batch independent, which may help to overcome memory constraints during training. A dataset with 91 images from 35 patients during Valsalva, contraction, and rest, all labeled by three operators, is used for training and evaluation in a leave-one-patient-out cross validation. Results show a median Dice similarity coefficient of 0.90 with an interquartile range of 0.08, with equivalent performance to the three operators (with a Williams' index of 1.03), and outperforming a U-Net architecture without the need for batch normalization. We conclude that the proposed fully automatic method achieved equivalent accuracy in segmenting the pelvic floor levator hiatus compared to a previous semiautomatic approach.
Bertocci, Gina E; Brown, Nathan P; Mich, Patrice M
2017-01-01
OBJECTIVE To evaluate effects of an orthosis on biomechanics of a cranial cruciate ligament (CrCL)-deficient canine stifle joint by use of a 3-D quasistatic rigid-body pelvic limb computer model simulating the stance phase of gait and to investigate influences of orthosis hinge stiffness (durometer). SAMPLE A previously developed computer simulation model for a healthy 33-kg 5-year-old neutered Golden Retriever. PROCEDURES A custom stifle joint orthosis was implemented in the CrCL-deficient pelvic limb computer simulation model. Ligament loads, relative tibial translation, and relative tibial rotation in the orthosis-stabilized stifle joint (baseline scenario; high-durometer hinge]) were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. Sensitivity analysis was conducted to evaluate the influence of orthosis hinge stiffness on model outcome measures. RESULTS The orthosis decreased loads placed on the caudal cruciate and lateral collateral ligaments and increased load placed on the medial collateral ligament, compared with loads for the CrCL-intact stifle joint. Ligament loads were decreased in the orthosis-managed CrCL-deficient stifle joint, compared with loads for the CrCL-deficient stifle joint. Relative tibial translation and rotation decreased but were not eliminated after orthosis management. Increased orthosis hinge stiffness reduced tibial translation and rotation, whereas decreased hinge stiffness increased internal tibial rotation, compared with values for the baseline scenario. CONCLUSIONS AND CLINICAL RELEVANCE Stifle joint biomechanics were improved following orthosis implementation, compared with biomechanics of the CrCL-deficient stifle joint. Orthosis hinge stiffness influenced stifle joint biomechanics. An orthosis may be a viable option to stabilize a CrCL-deficient canine stifle joint.
Modulation of the cytosolic androgen receptor in striated muscle by sex steroids
NASA Technical Reports Server (NTRS)
Rance, N. E.; Max, S. E.
1982-01-01
The influence of orchiectomy (GDX) and steroid administration on the level of the cytosolic androgen receptor in the rat levator ani muscle and in rat skeletal muscles (tibialis anterior and extensor digitorum longus) was studied. Androgen receptor binding to muscle cytosol was measured using H-3 methyltrienolone (R1881) as ligand, 100 fold molar excess unlabeled R1881 to assess nonspecific binding, and 500 fold molar excess of triamcinolone acetonide to prevent binding to glucocorticoid and progestin receptors. Results demonstrate that modification of the levels of sex steroids can alter the content of androgen receptors of rat striated muscle. Data suggest that: (1) cytosolic androgen receptor levels increase after orchiectomy in both levator ani muscle and skeletal muscle; (2) the acute increase in receptor levels is blocked by an inhibitor of protein synthesis; and (3) administration of estradiol-17 beta to castrated animals increases receptor binding in levator ani muscle but not in skeletal muscle.
Tracy, Paige V.; DeLancey, John O.; Ashton-Miller, James A.
2016-01-01
Because levator ani (LA) muscle injuries occur in approximately 13% of all vaginal births, insights are needed to better prevent them. In Part I of this paper, we conducted an analysis of the bony and soft tissue factors contributing to the geometric “capacity” of the maternal pelvis and pelvic floor to deliver a fetal head without incurring stretch injury of the maternal soft tissue. In Part II, we quantified the range in demand, represented by the variation in fetal head size and shape, placed on the maternal pelvic floor. In Part III, we analyzed the capacity-to-demand geometric ratio, g, in order to determine whether a mother can deliver a head of given size without stretch injury. The results of a Part I sensitivity analysis showed that initial soft tissue loop length (SL) had the greatest effect on maternal capacity, followed by the length of the soft tissue loop above the inferior pubic rami at ultimate crowning, then subpubic arch angle (SPAA) and head size, and finally the levator origin separation distance. We found the more caudal origin of the puborectal portion of the levator muscle helps to protect it from the stretch injuries commonly observed in the pubovisceral portion. Part II fetal head molding index (MI) and fetal head size revealed fetal head circumference values ranging from 253 to 351 mm, which would increase up to 11 mm upon face presentation. The Part III capacity-demand analysis of g revealed that, based on geometry alone, the 10th percentile maternal capacity predicted injury for all head sizes, the 25th percentile maternal capacity could deliver half of all head sizes, while the 50th percentile maternal capacity could deliver a head of any size without injury. If ultrasound imaging could be operationalized to make measurements of ratio g, it might be used to usefully inform women on their level of risk for levator injury during vaginal birth. PMID:26746116
Tracy, Paige V; DeLancey, John O; Ashton-Miller, James A
2016-02-01
Because levator ani (LA) muscle injuries occur in approximately 13% of all vaginal births, insights are needed to better prevent them. In Part I of this paper, we conducted an analysis of the bony and soft tissue factors contributing to the geometric "capacity" of the maternal pelvis and pelvic floor to deliver a fetal head without incurring stretch injury of the maternal soft tissue. In Part II, we quantified the range in demand, represented by the variation in fetal head size and shape, placed on the maternal pelvic floor. In Part III, we analyzed the capacity-to-demand geometric ratio, g, in order to determine whether a mother can deliver a head of given size without stretch injury. The results of a Part I sensitivity analysis showed that initial soft tissue loop length (SL) had the greatest effect on maternal capacity, followed by the length of the soft tissue loop above the inferior pubic rami at ultimate crowning, then subpubic arch angle (SPAA) and head size, and finally the levator origin separation distance. We found the more caudal origin of the puborectal portion of the levator muscle helps to protect it from the stretch injuries commonly observed in the pubovisceral portion. Part II fetal head molding index (MI) and fetal head size revealed fetal head circumference values ranging from 253 to 351 mm, which would increase up to 11 mm upon face presentation. The Part III capacity-demand analysis of g revealed that, based on geometry alone, the 10th percentile maternal capacity predicted injury for all head sizes, the 25th percentile maternal capacity could deliver half of all head sizes, while the 50th percentile maternal capacity could deliver a head of any size without injury. If ultrasound imaging could be operationalized to make measurements of ratio g, it might be used to usefully inform women on their level of risk for levator injury during vaginal birth.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-11
...), fasteners (7318.14, 7318.15, 7318.29), hinges (8302.10), brackets (8302.50), plates (8310.00), compressors..., Sub-Zero would be able to choose the duty rate during customs entry procedures that applies to...
NASA Astrophysics Data System (ADS)
Michalicek, M. Adrian; Bright, Victor M.
2001-10-01
This paper presents the design, fabrication, modeling, and testing of various arrays of cantilever micromirror devices integrated atop CMOS control electronics. The upper layers of the arrays are prefabricated in the MUMPs process and then flip-chip transferred to CMOS receiving modules using a novel latching off-chip hinge mechanism. This mechanism allows the micromirror arrays to be released, rotated off the edge of the host module and then bonded to the receiving module using a standard probe station. The hinge mechanism supports the arrays by tethers that are severed to free the arrays once bonded. The resulting devices are inherently planarized since the bottom of the first releasable MUMPs layer becomes the surface of the integrated mirror. The working devices are formed by mirror surfaces bonded to address electrodes fabricated above static memory cells on the CMOS module. These arrays demonstrate highly desirable features such as compatible address potentials, less than 2 nm of RMS roughness, approximately 1 micrometers of lateral position accuracy and the unique ability to metallize reflective surfaces without masking. Ultimately, the off-chip hinge mechanism enables very low-cost, simple, reliable, repeatable and accurate assembly of advanced MEMS and integrated microsystems without specialized equipment or complex procedures.
Correcting the Alar Base Retraction in Crooked Nose by Dissection of Levator Alaque Nasi Muscle.
Taş, Süleyman
2016-10-01
Nasal base retraction results from cephalic malposition of the alar base in the vertical plane causing disharmonies in the alar base. In literature, there are some excisional procedures to correct this deformity, but it may result to nostril distortion, stenosis, or upper lip elevation. Here, a new technique is reported for the correction of nasal base retraction in crooked nose by manipulating the levator labii alaeque nasi muscle. Sixteen patients, 6 women and 10 men ranging in age from 21 to 42 years, who have alar retraction with crooked nose, were operated, with a follow-up period of 12 months. Preoperative and postoperative frontal, profile, base, and oblique base views in a standard manner were taken and analyzed with Image software. Comparison of preoperative and postoperative photographs demonstrated that nasal base retractions were corrected in all cases without distortion and recurrence. Nasal obstruction was reduced after surgery, and self-evaluation of nasal patency scores significantly increased in all patients (P < 0.001). Functional and aesthetic outcomes were satisfactory for surgeons and the patients. Careful analysis to identify the deformity and proper selection of the technique will ensure a pleasing outcome. The new techniques presented for the correction of nasal base retraction and prevention of the recurrence of the dorsal deviation will help rhinoplasty surgeons obtain pleasing outcomes.
Ptosis assessment spectacles: a new method of measuring lid position and movement in children.
Khandwala, Mona; Dey, Sarju; Harcourt, Cassie; Wood, Clive; Jones, Carole A
2011-01-01
Accurate assessment of eyelid position and movement is vital in planning the surgical correction of ptosis. Conventional measurements taken using a millimeter ruler are considered the gold standard, although in young children this can be a difficult procedure. The authors have designed ptosis assessment spectacles with a measuring millimeter scale marked on the center of the lens to facilitate accurate assessment of eyelid position and function in children. The purpose of the study was to assess the accuracy and reproducibility of eyelid measurement using these ptosis assessment spectacles. Fifty-two children aged 2-12 years were recruited in this study. Each child underwent 2 sets of measurements. The first was undertaken by an ophthalmologist in the conventional manner using a ruler, and the second set made with ptosis assessment spectacles. On each occasion the palpebral aperture, skin crease, and levator function were recorded in millimeters. A verbal analog scale was used to assess parent satisfaction with each method. Clinically acceptable reproducibility was shown with the ruler and the spectacles for all measurements: palpebral aperture, skin crease, and levator function. Parents significantly preferred the glasses for measurement, as compared with the ruler (p < 0.05). The spectacles are as accurate as conventional methods of measurement, but are easier to use. Children tolerate these spectacles well, and most parents preferred them to the ruler.
Avulsion of the puborectalis muscle is associated with asymmetry of the levator hiatus.
Dietz, H P; Bhalla, R; Chantarasorn, V; Shek, K L
2011-06-01
To determine the degree of levator hiatal asymmetry in women with unilateral avulsion of the puborectalis muscle in order to estimate the likely effect of successful reconstruction. We reviewed datasets of women seen between May 2005 and January 2009 in a tertiary urogynecological unit. Archived ultrasound volume datasets were analyzed for hiatal dimensions and puborectalis muscle trauma in patients with unilateral avulsion. From 929 eligible datasets we identified 71 patients with isolated complete unilateral tears. Unilateral avulsion was associated with a significant increase in hiatal area (P ≤ 0.002). Relative to a hypothetical normal hiatus (intact hemi-area × 2), avulsion was associated with a larger hiatus on Valsalva maneuver (+2.1 cm(2) or 7%). Unilateral puborectalis muscle avulsion results in an asymmetric increase in the size of the levator hiatus. This increase is relatively minor, accounting for < 10% of hiatal area. Surgical repair of an avulsion may have only limited effects on hiatal dimensions. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Rader, Erik P; Cederna, Paul S; Weinzweig, Jeffrey; Panter, Kip E; Yu, Deborah; Buchman, Steven R; Larkin, Lisa M; Faulkner, John A
2007-03-01
Levator veli palatini muscles from normal palates of adult humans and goats are predominantly slow oxidative (type 1) fibers. However, 85% of levator veli palatini fibers from cleft palates of adult goats are physiologically fast (type 2). This fiber composition difference between cleft and normal palates may have implications in palatal function. For limb muscles, type 2 muscle fibers are more susceptible to lengthening contraction-induced injury than are type 1 fibers. We tested the hypothesis that, compared with single permeabilized levator veli palatini muscle fibers from normal palates of adult goats, those from cleft palates are more susceptible to lengthening contraction-induced injury. Congenital cleft palates were the result of chemically-induced decreased movement of the fetal head and tongue causing obstruction of palatal closure. Each muscle fiber was maximally activated and lengthened. Fiber type was determined by contractile properties and gel electrophoresis. Susceptibility to injury was assessed by measuring the decrease in maximum force following the lengthening contraction, expressed as a percentage of the initial force. Compared with fibers from normal palates that were all type 1 and had force deficits of 23 +/- 1%, fibers from cleft palates were all type 2 and sustained twofold greater deficits, 40 +/- 1% (p = .001). Levator veli palatini muscles from cleft palates of goats contain predominantly type 2 fibers that are highly susceptible to lengthening contraction-induced injury. This finding may have implications regarding palatal function and the incidence of velopharyngeal incompetence.
Androgen receptors in the pelvic diaphragm muscles of dogs with and without perineal hernia.
Mann, F A; Nonneman, D J; Pope, E R; Boothe, H W; Welshons, W V; Ganjam, V K
1995-01-01
Levator ani and coccygeus muscle estrogen and androgen receptors were measured in 6, healthy, > or = 5-year-old, noncastrated, male Beagles (controls) and in 24 dogs with perineal hernia. Estrogen and androgen receptor analyses were performed on levator ani and coccygeus muscle specimens obtained from control dogs at the time of castration; contralateral levator ani and coccygeus muscle specimens were assayed 2 months after castration. During herniorrhaphy of dogs with perineal hernia, levator ani (non-castrated, n = 12; castrated, n = 7) and/or coccygeus (noncastrated, n = 5; castrated, n = 4) muscle biopsy specimens were obtained for estrogen and androgen receptor analyses. For estrogen and androgen receptor assays, each muscle biopsy specimen was homogenized in Tris-EDTA-glycerol buffer, and centrifuged at 30,000 x g; extracts were used for binding with ligands: [3H]methyltrienolone (3HR1881) for androgen receptors, and [3H]estradiol-17 beta for estrogen receptors. Extracts were incubated overnight at 0 to 4 C. Nonspecific binding was estimated, using 100-fold concentration of cold ligands. Bound and free hormones were separated, using hydroxylapatite batch assay. Receptor numbers for each tissue were calculated as femtomoles (fmol) per milligram of protein. Quantified data were compared between precastration and postcastration controls, using a paired t-test. One-way ANOVA and Bonferroni post-hoc test were used to compare values for precastration controls, postcastration controls, castrated dogs with perineal hernia, and noncastrated dogs with perineal hernia. Significance was set at P < 0.05.(ABSTRACT TRUNCATED AT 250 WORDS)
Normative Velopharyngeal Data in Infants: Implications for Treatment of Cleft Palate.
Schenck, Graham C; Perry, Jamie L; Fang, Xiangming
2016-09-01
Identifying normative data related to velopharyngeal muscles and structures may have clinical significance for infants born with cleft palate, especially as they relate to selection of surgical intervention and postsurgical outcomes. Previous studies suggest that patients whose anatomy postsurgically is dissimilar to that of their normative counterparts are at risk for hypernasal speech. However, studies have not documented what constitutes "normal" anatomy for the clinically relevant population-that is, the infant population. The purpose of this study is to examine a magnetic resonance imaging database (n = 29) related to normative velopharyngeal structures and provide a preliminary comparison to 2 selected patients with repaired cleft palate. Twenty-nine healthy infants between 9 and 23 months of age (mean = 15.2 months) with normal craniofacial and velopharyngeal anatomy were recruited to participate in this study. Normative data were compared to 2 infants with repaired cleft palate between 13 and 15 months of age (mean = 14 months). Quantitative craniometric and velopharyngeal measures from the sagittal and oblique coronal image planes were collected. Variables of interest included: levator muscle, velar, and craniometric measures. Females demonstrated significantly larger intravelar segments compared with males. White infants demonstrated significantly larger levator muscles compared to non-white infants. Infants with repaired cleft palate demonstrated increased overall levator muscle length and levator extravelar length compared with infants with normal velopharyngeal anatomy.Data from the present study provide a normative database for future investigators to utilize as a comparative tool when evaluating infants with normal and abnormal velopharyngeal anatomy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Evidence. 965.9 Section 965.9 Postal Service UNITED STATES POSTAL SERVICE PROCEDURES RULES OF PRACTICE IN PROCEEDINGS RELATIVE TO MAIL DISPUTES § 965.9 Evidence. (a) In general, admissibility will hinge on relevancy and materiality. However, relevant...
Marcus Gunn jaw-winking synkinesis: clinical features and management.
Demirci, Hakan; Frueh, Bartley R; Nelson, Christine C
2010-07-01
To evaluate the clinical features including eyelid excursion and management of Marcus Gunn jaw-winking synkinesis (MGJWS). Observational case series. Forty-eight consecutive patients with MGJWS. Clinical features and management of 48 patients with MGJWS were reviewed retrospectively. Upper eyelid excursion was measured and graded. Complications of surgical intervention were evaluated. Resolution of MGJWS and symmetry of upper eyelids in primary position. Excursion of the ptotic eyelid with jaw movement in MGJWS was graded as mild (<2 mm) in 16% of patients, moderate (2-4 mm) in 76% of patients, and severe (> or = 5 mm) in 8% of patients. Thirty patients with moderate or severe MGJWS underwent disabling of the involved levator muscle and bilateral or unilateral frontalis suspension and had more than 6 months of follow-up. After a mean follow-up of 62 months, MGJWS resolved in 29 (97%) patients and improved from 6 mm to 2 mm in 1 (3%) patient. Relative upper eyelid height was within 1 mm in 87% of patients in primary position and within 1 mm in 80% of patients in downgaze. Twenty-six patients had bilateral frontalis suspension with disabling of unilateral levator muscle on the involved side. Relative upper eyelid height was within 1 mm in 88% of patients in the primary position and within 1 mm in 88% of patients in downgaze. Four non-amblyopic patients had unilateral frontalis suspension with levator muscle disabling. Relative upper eyelid height was symmetrical in 75% of the patients in primary position and in 25% of patients in downgaze. Complications included eyelash ptosis in 10% of the patients, loss of eyelid crease in 10%, and entropion in 3%. Most of the patients with MGJWS exhibited moderate eyelid excursion. Disabling of the involved levator muscle and bilateral frontalis suspension and, in selected cases, disabling of the involved levator muscle and unilateral frontalis suspension were effective in the treatment of MGJWS. Eyelash ptosis and loss of eyelid crease were the most common complications, each occurring in 10% of the patients. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Is it necessary to diagnose levator avulsion on pelvic floor muscle contraction?
Dietz, H P; Pattillo Garnham, A; Guzmán Rojas, R
2017-02-01
Avulsion of the levator ani muscle commonly occurs at vaginal birth. This condition is usually diagnosed by translabial ultrasound (TLUS) during pelvic floor muscle contraction (PFMC). Some patients are unable to achieve a satisfactory PFMC and in these cases avulsion is assessed at rest. The aim of this study was to validate the diagnosis of levator avulsion by means of TLUS at rest. This was a retrospective study of 233 women seen at a tertiary urogynecological center. All women underwent four-dimensional TLUS in the supine position and after voiding. Volumes were obtained on maximal PFMC and at rest. Analysis of the volumes was performed with the observer blinded against all clinical data. Avulsion was defined as an abnormal levator ani muscle insertion that was visible in at least three consecutive axial plane slices, at and above the level of minimal hiatal dimensions, at 2.5-mm intervals. We examined the correlation between both assessment methods using Cohen's kappa coefficient and tested the association of each method with female pelvic organ prolapse on clinical examination, organ descent on ultrasound and hiatal ballooning. In total, datasets from 202 women were available for analysis. The correlation between a diagnosis of avulsion in volumes obtained at rest and those on PFMC was moderate, with a kappa value of 0.583 (95% CI, 0.484-0.683). Agreement for defects visualized on single slices was moderate, with a kappa value of 0.556 (95% CI, 0.520-0.591). When avulsion diagnoses at rest and on PFMC were tested against symptoms of prolapse, and prolapse on clinical examination and on ultrasound, neither of the two methods was superior. Although tomographic ultrasound imaging during PFMC enhances tissue discrimination, this may not translate to superior diagnostic performance. Hence, volumes obtained at rest may be used in women unable to contract their pelvic floor. The diagnosis of levator avulsion by tomographic pelvic floor ultrasound is equally valid when performed at rest or on PFMC. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Prominent expression of phosphodiesterase 5 in striated muscle of the rat urethra and levator ani.
Lin, Guiting; Huang, Yun-Ching; Wang, Guifang; Lue, Tom F; Lin, Ching-Shwun
2010-08-01
We investigated phosphodiesterase 5 distribution and activity in the urethra. Rat tissues were examined for phosphodiesterase 5 and alpha-smooth muscle actin expression. Urethral phosphodiesterase 5 activity was examined by tissue bath in the presence of sildenafil (Pfizer, New York, New York). Anti-alpha-smooth muscle actin antibody (Abcam) stained all known smooth muscles in all tested tissues and revealed a few smooth muscle fibers in the levator ani muscle. Anti-phosphodiesterase 5 antibody (Abcam) stained smooth muscle in the penis and bladder but not striated leg muscle. However, it stained predominantly striated muscle in the urethra and the levator ani muscle. In the urethra the amount of phosphodiesterase 5 in striated muscle was 6 times that in smooth muscle. In urethral striated muscle phosphodiesterase 5 expression was localized to Z-band striations. Smooth and striated muscle intermingling was clearly visible on the inner and outer rims of the circularly arranged striated muscle layer. Relaxation of precontracted urethral tissues by sodium nitroprusside (Sigma-Aldrich) was enhanced by sildenafil, indicating phosphodiesterase 5 activity, which was primarily located in the striated muscle according to phosphodiesterase 5 staining. Despite its presumed smooth muscle specificity phosphodiesterase 5 was predominantly expressed in the striated muscle of the urethra and in the levator ani muscle. Results are consistent with earlier studies in which these striated muscles were developmentally related to smooth muscle. They also suggest that these striated muscles are possibly regulated by phosphodiesterase 5. Copyright (c) 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Evidence. 963.15 Section 963.15 Postal Service UNITED STATES POSTAL SERVICE PROCEDURES RULES OF PRACTICE IN PROCEEDINGS RELATIVE TO VIOLATIONS OF THE PANDERING ADVERTISEMENTS STATUTE, 39 U.S.C. 3008 § 963.15 Evidence. (a) In general, admissibility will hinge...
Bharucha, Adil E.; Lee, Tae Hee
2016-01-01
Although pelvic pain is a symptom of several structural anorectal and pelvic disorders (eg, anal fissure, endometriosis, and pelvic inflammatory disease), this comprehensive review will focus on the three most common nonstructural, or functional, disorders associated with pelvic pain: functional anorectal pain (ie, levator ani syndrome, unspecified anorectal pain, and proctalgia fugax), interstitial cystitis/bladder pain syndrome, and chronic prostatitis/chronic pelvic pain syndrome. The first two conditions occur in both sexes, while the latter occurs only in men. They are defined by symptoms, supplemented with levator tenderness (levator ani syndrome) and bladder mucosal inflammation (interstitial cystitis). Although distinct, these conditions share several similarities, including associations with dysfunctional voiding or defecation, comorbid conditions (eg, fibromyalgia, depression), impaired quality of life, and increased health care utilization. Several factors, including pelvic floor muscle tension, peripheral inflammation, peripheral and central sensitization, and psychosocial factors, have been implicated in the pathogenesis. The management is tailored to symptoms, is partly supported by clinical trials, and includes multidisciplinary approaches such as lifestyle modifications and pharmacologic, behavioral, and physical therapy. Opioids should not be avoided, and surgery has a limited role, primarily in refractory interstitial cystitis. PMID:27712641
Functional disorders of the anus and rectum
Whitehead, W; Wald, A; Diamant, N; Enck, P; Pemberton, J; Rao, S
1999-01-01
In this report the functional anorectal disorders, the etiology of which is currently unknown or related to the abnormal functioning of normally innervated and structurally intact muscles, are discussed. These disorders include functional fecal incontinence, functional anorectal pain, including levator ani syndrome and proctalgia fugax, and pelvic floor dyssynergia. The epidemiology of each disorder is defined and discussed, their pathophysiology is summarized and diagnostic approaches and treatment are suggested. Some suggestions for the direction of future research on these disorders are also given. Keywords: fecal incontinence; pelvic floor dyssynergia; anismus; proctalgia fugax; levator ani syndrome; constipation; Rome II PMID:10457046
Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å
2015-10-01
To study possible associations between mode of delivery and pelvic organ prolapse (POP) and pelvic floor muscle trauma 16-24 years after first delivery and, in particular, to identify differences between forceps and vacuum delivery. This was a cross-sectional study including 608 women who delivered their first child in 1990-1997 and were examined with POP quantification (POP-Q) and pelvic floor ultrasound in 2013-2014. Outcome measures were POP ≥ Stage 2 or previous prolapse surgery, levator avulsion and levator hiatal area on Valsalva. Univariable and multivariable logistic regression analyses and ANCOVA were applied to identify outcome variables associated with mode of delivery. Comparing forceps to vacuum delivery, the adjusted odds ratios (aOR) were 1.72 (95% CI, 1.06-2.79; P = 0.03) for POP ≥ Stage 2 or previous prolapse surgery and 4.16 (95% CI, 2.28-7.59; P < 0.01) for levator avulsion. Hiatal area on Valsalva was larger, with adjusted mean difference (aMD) of 4.75 cm(2) (95% CI, 2.46-7.03; P < 0.01). Comparing forceps with normal vaginal delivery, the adjusted odds ratio (aOR) was 1.74 (95% CI, 1.12-2.68; P = 0.01) for POP ≥ Stage 2 or surgery and 4.35 (95% CI, 2.56-7.40; P < 0.01) for levator avulsion; hiatal area on Valsalva was larger, with an aMD of 3.84 cm(2) (95% CI, 1.78-5.90; P < 0.01). Comparing Cesarean delivery with normal vaginal delivery, aOR was 0.06 (95% CI, 0.02-0.14; P < 0.01) for POP ≥ Stage 2 or surgery and crude OR was 0.00 (95% CI, 0.00-0.30; P < 0.01) for levator avulsion; hiatal area on Valsalva was smaller, with an aMD of -8.35 cm(2) (95% CI, -10.87 to -5.84; P < 0.01). No differences were found between vacuum and normal vaginal delivery. We found that mode of delivery was associated with POP and pelvic floor muscle trauma in women from a general population, 16-24 years after their first delivery. Forceps was associated with significantly more POP, levator avulsion and larger hiatal areas than were vacuum and normal vaginal deliveries. There were no statistically significant differences between vacuum and normal vaginal deliveries. Cesarean delivery was associated with significantly less POP and pelvic floor muscle trauma than were normal or operative vaginal delivery. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Sarmento-Soares, Luisa Maria; Porto, Marcovan
2006-02-01
Glanidium melanopterum Miranda Ribeiro, a typical representative of the subfamily Centromochlinae (Siluriformes: Auchenipteridae), is herein described myologically and compared to other representative species within the group, Glanidium ribeiroi, G. leopardum, Tatia neivai, T. intermedia, T. creutzbergi, Centromochlus heckelii, and C. existimatus. The structure of seven pairs of striated cephalic muscles was compared anatomically: adductor mandibulae, levator arcus palatini, dilatator operculi, adductor arcus palatini, extensor tentaculi, retractor tentaculi, and levator operculi. We observed broad adductor mandibulae muscles in both Glanidium and Tatia, catfishes with depressed heads and smaller eyes. Similarities between muscles were observed: the presence of a large aponeurotic insertion for the levator arcus palatini muscle; an adductor arcus palatini muscle whose origin spread over the orbitosphenoid, pterosphenoid, and parasphenoid; and the extensor tentaculi muscle broadly attached to the autopalatine. There is no retractor tentaculi muscle in either the Glanidium or Tatia species. On the other hand, in Centromochlus, with forms having large eyes and the tallest head, the adductor mandibulae muscles are slim; there is a thin aponeurotic or muscular insertion for the levator arcus palatini muscle; the adductor arcus palatini muscle originates from a single osseous process, forming a keel on the parasphenoid; the extensor tentaculi muscle is loosely attached to the autopalatine, permitting exclusive rotating and sliding movements between this bone and the maxillary. The retractor tentaculi muscle is connected to the maxilla through a single tendon, so that both extensor and retractor tentaculi muscles contribute to a wide array of movements of the maxillary barbels. A discussion on the differences in autopalatine-maxillary movements among the analyzed groups is given. (c) 2005 Wiley-Liss, Inc.
DOT National Transportation Integrated Search
2014-05-01
Kansas Department of Transportation (KDOT) has implemented the new AASHTO-LRFD provisions in the state specific : LRFD design procedure (KDOT LRFD). Most of the existing bridges constructed before the new provisions, have been designed : based on the...
DOT National Transportation Integrated Search
2014-05-01
Kansas Department of Transportation (KDOT) has implemented the new AASHTO : LRFD provisions in the state specific LRFD design procedure (KDOT-LRFD). There : have been some significant updates in new version of AASHTO-LRFD (2010), compared : to previo...
Shape Memory Composite Hybrid Hinge
NASA Technical Reports Server (NTRS)
Fang, Houfei; Im, Eastwood; Lin, John; Scarborough, Stephen
2012-01-01
There are two conventional types of hinges for in-space deployment applications. The first type is mechanically deploying hinges. A typical mechanically deploying hinge is usually composed of several tens of components. It is complicated, heavy, and bulky. More components imply higher deployment failure probability. Due to the existence of relatively moving components among a mechanically deploying hinge, it unavoidably has microdynamic problems. The second type of conventional hinge relies on strain energy for deployment. A tape-spring hinge is a typical strain energy hinge. A fundamental problem of a strain energy hinge is that its deployment dynamic is uncontrollable. Usually, its deployment is associated with a large impact, which is unacceptable for many space applications. Some damping technologies have been experimented with to reduce the impact, but they increased the risks of an unsuccessful deployment. Coalescing strain energy components with shape memory composite (SMC) components to form a hybrid hinge is the solution. SMCs are well suited for deployable structures. A SMC is created from a high-performance fiber and a shape memory polymer resin. When the resin is heated to above its glass transition temperature, the composite becomes flexible and can be folded or packed. Once cooled to below the glass transition temperature, the composite remains in the packed state. When the structure is ready to be deployed, the SMC component is reheated to above the glass transition temperature, and it returns to its as-fabricated shape. A hybrid hinge is composed of two strain energy flanges (also called tape-springs) and one SMC tube. Two folding lines are placed on the SMC tube to avoid excessive strain on the SMC during folding. Two adapters are used to connect the hybrid hinge to its adjacent structural components. While the SMC tube is heated to above its glass transition temperature, a hybrid hinge can be folded and stays at folded status after the temperature is reduced to below its glass transition temperature. After the deployable structure is launched in space, the SMC tube is reheated and the hinge is unfolded to deploy the structure. Based on test results, the hybrid hinge can achieve higher than 99.999% shape recovery. The hybrid hinge inherits all of the good characteristics of a tape-spring hinge such as simplicity, light weight, high deployment reliability, and high deployment precision. Conversely, it eliminates the deployment impact that has significantly limited the applications of a tape-spring hinge. The deployment dynamics of a hybrid hinge are in a slow and controllable fashion. The SMC tube of a hybrid hinge is a multifunctional component. It serves as a deployment mechanism during the deployment process, and also serves as a structural component after the hinge is fully deployed, which makes a hybrid hinge much stronger and stiffer than a tape-spring hinge. Unlike a mechanically deploying hinge that uses relatively moving components, a hybrid hinge depends on material deformation for its packing and deployment. It naturally eliminates the microdynamic phenomenon.
Rao, Satish S. C.; Bharucha, Adil E.; Chiarioni, Giuseppe; Felt-Bersma, Richelle; Knowles, Charles; Malcolm, Allison; Wald, Arnold
2016-01-01
This report defines criteria and reviews the epidemiology, pathophysiology, and management of the following common anorectal disorders: fecal incontinence (FI), functional anorectal pain, and functional defecation disorders. FI is defined as the recurrent uncontrolled passage of fecal material for at least 3 months. The clinical features of FI are useful for guiding diagnostic testing and therapy. Anorectal manometry and imaging are useful for evaluating anal and pelvic floor structure and function. Education, antidiarrheals, and biofeedback therapy are the mainstay of management; surgery may be useful in refractory cases. Functional anorectal pain syndromes are defined by clinical features and categorized into 3 subtypes. In proctalgia fugax, the pain is typically fleeting and lasts for seconds to minutes. In levator ani syndrome and unspecified anorectal pain, the pain lasts more than 30 minutes, but in levator ani syndrome there is puborectalis tenderness. Functional defecation disorders are defined by ≥2 symptoms of chronic constipation or irritable bowel syndrome with constipation, and with ≥2 features of impaired evacuation, that is, abnormal evacuation pattern on manometry, abnormal balloon expulsion test, or impaired rectal evacuation by imaging. It includes 2 subtypes: dyssynergic defecation and inadequate defecatory propulsion. Pelvic floor biofeedback therapy is effective for treating levator ani syndrome and defecatory disorders. PMID:27144630
Bharucha, Adil E; Lee, Tae Hee
2016-10-01
Although pelvic pain is a symptom of several structural anorectal and pelvic disorders (eg, anal fissure, endometriosis, and pelvic inflammatory disease), this comprehensive review will focus on the 3 most common nonstructural, or functional, disorders associated with pelvic pain: functional anorectal pain (ie, levator ani syndrome, unspecified anorectal pain, and proctalgia fugax), interstitial cystitis/bladder pain syndrome, and chronic prostatitis/chronic pelvic pain syndrome. The first 2 conditions occur in both sexes, while the latter occurs only in men. They are defined by symptoms, supplemented with levator tenderness (levator ani syndrome) and bladder mucosal inflammation (interstitial cystitis). Although distinct, these conditions share several similarities, including associations with dysfunctional voiding or defecation, comorbid conditions (eg, fibromyalgia, depression), impaired quality of life, and increased health care utilization. Several factors, including pelvic floor muscle tension, peripheral inflammation, peripheral and central sensitization, and psychosocial factors, have been implicated in the pathogenesis. The management is tailored to symptoms, is partly supported by clinical trials, and includes multidisciplinary approaches such as lifestyle modifications and pharmacological, behavioral, and physical therapy. Opioids should be avoided, and surgical treatment has a limited role, primarily in refractory interstitial cystitis. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
What's new in the functional anatomy of pelvic organ prolapse?
DeLancey, John O L
2016-10-01
Provide an evidence-based review of pelvic floor functional anatomy related to pelvic organ prolapse. Pelvic organ support depends on interactions between the levator ani muscle and pelvic connective tissues. Muscle failure exposes the vaginal wall to a pressure differential producing abnormal tension on the attachments of the pelvic organs to the pelvic sidewall. Birth-induced injury to the pubococcygeal portion of the levator ani muscle is seen in 55% of women with prolapse and 16% of women with normal support. Failure of the lateral connective tissue attachments between the uterus and vagina to the pelvic wall (cardinal, uterosacral, and paravaginal) are strongly related with prolapse (effect sizes ∼2.5) and are also highly correlated with one another (r ∼ 0.85). Small differences exist with prolapse in factors involving the vaginal wall length and width (effect sizes ∼1). The primary difference in ligament properties between women with and without prolapse is found in ligament length. Only minor differences in ligament stiffness are seen. Pelvic organ prolapse occurs because of injury to the levator ani muscles and failure of the lateral connections between the pelvic organs to the pelvic sidewall. Abnormalities of the vaginal wall fascial tissues may play a minor role.
Development of novel hybrid flexure-based microgrippers for precision micro-object manipulation.
Mohd Zubir, Mohd Nashrul; Shirinzadeh, Bijan; Tian, Yanling
2009-06-01
This paper describes the process of developing a microgripper that is capable of high precision and fidelity manipulation of micro-objects. The design adopts the concept of flexure-based hinges on its joints to provide the rotational motion, thus eliminating the inherent nonlinearities associated with the application of conventional rigid hinges. A combination of two modeling techniques, namely, pseudorigid body model and finite element analysis was utilized to expedite the prototyping procedure, which leads to the establishment of a high performance mechanism. A new hybrid compliant structure integrating cantilever beam and flexural hinge configurations within microgripper mechanism mainframe has been developed. This concept provides a novel approach to harness the advantages within each individual configuration while mutually compensating the limitations inherent between them. A wire electrodischarge machining technique was utilized to fabricate the gripper out of high grade aluminum alloy (Al 7075T6). Experimental studies were conducted on the model to obtain various correlations governing the gripper performance as well as for model verification. The experimental results demonstrate high level of compliance in comparison to the computational results. A high amplification characteristic and maximum achievable stroke of 100 microm can be achieved.
Development of novel hybrid flexure-based microgrippers for precision micro-object manipulation
NASA Astrophysics Data System (ADS)
Mohd Zubir, Mohd Nashrul; Shirinzadeh, Bijan; Tian, Yanling
2009-06-01
This paper describes the process of developing a microgripper that is capable of high precision and fidelity manipulation of micro-objects. The design adopts the concept of flexure-based hinges on its joints to provide the rotational motion, thus eliminating the inherent nonlinearities associated with the application of conventional rigid hinges. A combination of two modeling techniques, namely, pseudorigid body model and finite element analysis was utilized to expedite the prototyping procedure, which leads to the establishment of a high performance mechanism. A new hybrid compliant structure integrating cantilever beam and flexural hinge configurations within microgripper mechanism mainframe has been developed. This concept provides a novel approach to harness the advantages within each individual configuration while mutually compensating the limitations inherent between them. A wire electrodischarge machining technique was utilized to fabricate the gripper out of high grade aluminum alloy (Al 7075T6). Experimental studies were conducted on the model to obtain various correlations governing the gripper performance as well as for model verification. The experimental results demonstrate high level of compliance in comparison to the computational results. A high amplification characteristic and maximum achievable stroke of 100 μm can be achieved.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Surfaces § 25.657 Hinges. (a) For control surface hinges, including ball, roller, and self-lubricated bearing hinges, the approved rating of... hinge line. [Amdt. 25-23, 35 FR 5674, Apr. 8, 1970] Control Systems ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Surfaces § 25.657 Hinges. (a) For control surface hinges, including ball, roller, and self-lubricated bearing hinges, the approved rating of... hinge line. [Amdt. 25-23, 35 FR 5674, Apr. 8, 1970] Control Systems ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Surfaces § 25.657 Hinges. (a) For control surface hinges, including ball, roller, and self-lubricated bearing hinges, the approved rating of... hinge line. [Amdt. 25-23, 35 FR 5674, Apr. 8, 1970] Control Systems ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Surfaces § 25.657 Hinges. (a) For control surface hinges, including ball, roller, and self-lubricated bearing hinges, the approved rating of... hinge line. [Amdt. 25-23, 35 FR 5674, Apr. 8, 1970] Control Systems ...
Blepharoplasty techniques in the management of orbito-temporal neurofibromatosis.
Li, Jin; Lin, Ming; Shao, Chunyi; Ge, Shengfang; Fan, Xianqun
2014-11-01
We aimed to present blepharoplasty techniques we used for severe orbito-temporal neurofibromatosis (NF). A retrospective noncomparative single-center case study was undertaken on patients with orbito-temporal NF. Twenty-two patients with orbito-temporal NF treated at the Department of Ophthalmology of Shanghai Ninth People's Hospital between 2007 and 2011 participated in the study. They underwent a standard ophthalmologic assessment for orbito-temporal NF involving both the orbito-temporal soft tissue and bony orbits. The orbits were examined with three-dimensional computed tomography (CT) and all 22 patients underwent tumor debulking, blepharoplasty, and orbital reconstruction. We modified the conventional procedures. Our reconstructive techniques included eyelid reduction; lateral canthal reattachment; for patients with collapse of the lateral orbital margin, reconstruction of the orbital margin to be performed before reattaching the lateral canthus to the implanted titanium mesh; anterior levator resection; and frontalis suspension according to preoperative levator muscle function. Visual acuity, tumor recurrence, and postoperative palpebral fissure and orbital appearance were evaluated to assess outcomes. Acceptable cosmetic results were obtained in 22 patients after debulking of the orbito-temporal NF and surgical reconstruction. There was no loss of vision or visual impairment postoperatively. All patients did not display recrudescence after a follow-up period of >1 year. Three patients with residual ptosis were successfully treated with a second ptosis repair. We believe that the blepharoplasty techniques described in the treatment of orbito-palpebral NF may provide both functional and esthetic benefits. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Fujita, Kenya; Matsuo, Kiyoshi; Yuzuriha, Shunsuke
2013-01-01
We have previously reported that fascia lata grafts with peritendinous areolar tissue used to treat severe congenital blepharoptosis gradually shrink within 6 weeks postoperatively and maintain long-term shrinkage of 15.5% on average. Accordingly, it seemed possible that a fascia lata graft without peritendinous areolar tissue would shrink more than the one with peritendinous areolar tissue in a clinical setting. We evaluated this possibility in a patient with Klippel-Feil syndrome having postoperative deep atonic nasopharynx. In combination with intravelar veloplasty and palatal lengthening with modified bilateral buccinator sandwich pushback, a ringed fascia lata without peritendinous areolar tissue encircling the levator veli palatini and superior constrictor muscles was grafted to cure severe velopharyngeal incompetence. Obstructive sleep apnea did not occur following surgery. Pharyngoscopy, videofluoroscopy, and nasometry showed no amelioration of velopharyngeal incompetence at 1 month postoperatively, but marked velopharyngeal incompetence reduction was evident at 4 months and 2 years after surgery. The extended recovery period suggests that the anticipated postoperative shrinkage of the ringed fascia lata without peritendinous areolar tissue played a more prominent role than intravelar veloplasty and palatal lengthening, which posteroinferiorly elongated the atonic soft palate. Although the pharyngeal flap procedure is the most popular technique for treatment of velopharyngeal incompetence, it is sometimes accompanied by respiratory complications. Thus, the gradual postoperative shrinkage of a ringed fascia lata graft encircling the velopharyngeal muscles functions as an intravelar palatal lift and may be an additional surgical method with less respiratory complications to narrow atonic nasopharyngeal port.
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Surfaces § 23.657 Hinges. (a) Control surface hinges, except ball and roller bearing hinges, must have a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Surfaces § 23.657 Hinges. (a) Control surface hinges, except ball and roller bearing hinges, must have a...
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Surfaces § 23.657 Hinges. (a) Control surface hinges, except ball and roller bearing hinges, must have a...
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Surfaces § 23.657 Hinges. (a) Control surface hinges, except ball and roller bearing hinges, must have a...
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Surfaces § 23.657 Hinges. (a) Control surface hinges, except ball and roller bearing hinges, must have a...
One Stage Conversion of an Infected Fused Knee to Total Knee Replacement - A Surgical Challenge
Ravikumar, Mukartihal; Kendoff, Daniel; Citak, Mustafa; Luck, Stefan; Gehrke, Thorsten; Zahar, Akos
2013-01-01
Background and Purpose: Two-stage revision arthroplasty is a common technique for the treatment of infected total knee replacement. Few reports have addressed the conversion of a fused knee into a total knee replacement. However, there is no case reported of converting an infected fused knee into a hinge knee using a one-stage procedure. Methods: We report on a 51-year old male patient with an infected fused knee after multiple surgeries. Results and Interpretation: A one-stage conversion of septic fused knee into total knee arthroplasty by a rotational hinge prosthesis was performed. The case highlights that with profound preoperative assessment, meticulous surgical technique, combined antibiotic treatment and the right implant, one-stage revision in a surgical challenge may have a role as a treatment option with good functional outcome. PMID:23526706
Successful use of botulinum toxin type a in the treatment of refractory postoperative dyspareunia.
Park, Amy J; Paraiso, Marie Fidela R
2009-08-01
Refractory dyspareunia presents a challenging therapeutic dilemma. A woman with defecatory dysfunction and dyspareunia presented with stage 2 prolapse. She underwent laparoscopic and vaginal pelvic floor reconstruction with excision of endometriosis. The patient experienced increased dyspareunia and de novo vaginismus postoperatively that were refractory to trigger point injections, physical therapy, and medical and surgical management. She underwent botulinum toxin type A injections into her levator ani muscles, which allowed her to have sexual intercourse again after 2 years of apareunia with no recurrence of pain for 12 months. Injecting botulinum toxin into the levator ani muscles shows promise for postoperative patients who develop vaginismus and do not respond to conservative therapy.
50 CFR 648.144 - Gear restrictions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... spacing may be adjusted pursuant to the procedures in § 648.140. (3) Ghost panel. Black sea bass traps or pots must contain a ghost panel affixed to the trap or pot with degradable fasteners and hinges. The opening to be covered by the ghost panel must measure at least 3.0 inches (7.62 cm) by 6.0 inches (15.24...
Pushover analysis of reinforced concrete frames considering shear failure at beam-column joints
NASA Astrophysics Data System (ADS)
Sung, Y. C.; Lin, T. K.; Hsiao, C. C.; Lai, M. C.
2013-09-01
Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the plastic hinges (PHs) on such main structural components as columns, beams and walls, the complex behavior of shear failure at beam-column joints (BCJs) during major earthquakes is commonly neglected. This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures. Based on the specifications of FEMA-356, a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established, allowing a sophisticated PA to be performed. To verify the validity of this method, the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements. By considering shear failure at BCJs, the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames, including seismic capacity and the progressive failure sequence of joints, in a precise and effective manner.
Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis.
Han, Xinwei; Al-Tariq, Quazi; Zhao, Yanle; Li, Lei; Cheng, Zhe; Wang, Huaqi; Liu, Chao; Jiao, Dechao; Wu, Gang
2017-08-01
To address the limitations of silicone stents, we designed a hinged self-expandable covered metallic stent. The aim of this study was to evaluate the safety and efficacy of the customized stents in clinical applications. This was a retrospective analysis. Under conscious sedation and local anesthesia, the stents were implanted or removed by interventional radiologists, with fluoroscopic guidance. Of 24 patients with benign main bronchial stenosis, stents were successfully placed in 21 (87.5%). The low-pressure balloon before dilation failed in 1 case (4.17%) of left main bronchial cicatricial stenosis. In 2 other cases (8.33%), stent placement was abandoned. Stents were successfully removed between 29 and 103 days after the procedure. After stent removal, the follow-up lasted for at least 12 months. Restenosis occurred only in 1 case (4.55%) owing to bronchial collapse 3 days after stent removal. Dyspnea occurred in another case (4.55%) at 2 months after retrieval; recurrence was confirmed using bronchoscopy, leading to a left pneumonectomy. The described procedure is safe and easy to be performed and avoids the use of intubation, bronchoscopy, and general anesthesia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Lee, Ji-Hyun; Cynn, Heon-Seock; Choi, Woo-Jeong; Jeong, Hyo-Jung; Yoon, Tae-Lim
2016-05-01
The objective of this study was to introduce levator scapulae (LS) measurement using a caliper and the levator scapulae index (LSI) and to investigate intra- and interrater reliability of the LSI in subjects with and without scapular downward rotation syndrome (SDRS). Two raters measured LS length twice in 38 subjects (19 with SDRS and 19 without SDRS). For reliability testing, intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated. Intrarater reliability analysis resulted with ICCs ranging from 0.94 to 0.98 in subjects with SDRS and 0.96 to 0.98 in subjects without SDRS. These results represented that intrarater reliability in both groups were excellent for measuring LS length with the LSI. Interrater reliability was good (ICC: 0.82) in subjects with SDRS; however, interrater reliability was moderate (ICC: 0.75) in subjects without SDRS. Additionally, SEM and MDC were 0.13% and 0.36% in subjects with SDRS and 0.35% and 0.97% in subjects without SDRS. In subjects with SDRS, low dispersion of the measurement errors and MDC were shown. This study suggested that the LSI is a reliable method to measure LS length and is more reliable for subjects with SDRS. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gachon, B; Desseauve, D; Fradet, L; Decatoire, A; Lacouture, P; Pierre, F; Fritel, X
2016-06-01
The role of pregnancy in pelvic floor disorders occurrence remains poorly known. It might exist a link between changes in ligamentous laxity and changes in pelvic organ mobility during this period. Our objective was to conduct a non-systematic review of literature about changes in pelvic organ mobility as well as in ligamentous laxity during pregnancy and postpartum. From the PubMed, Medline, Cochrane Library and Web of Science database we have selected works which pertains clinical assessment of pelvic organ mobility (pelvic organ prolapse quantification), ultrasound assessment of levator hiatus and urethral mobility, ligamentous laxity assessment during pregnancy and postpartum. Clinical assessments performed in these works show an increase of pelvic organ mobility and perineal distension during pregnancy followed by a recovery phase during postpartum. Pelvic floor imaging shows an increase of levator hiatus area and urethral mobility during pregnancy then a recovery phase in postpartum. Different authors also report an increase of ligamentous laxity (upper and lower limbs) during pregnancy followed by a decrease phase in postpartum. Pelvic organ mobility, ligamentous laxity, levator hiatus and urethral mobility change in a similarly way during pregnancy (increase of mobility or distension) and postpartum (recovery). 3. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Jeong, Hyo-Jung; Cynn, Heon-Seock; Yi, Chung-Hwi; Yoon, Jang-Whon; Lee, Ji-Hyun; Yoon, Tae-Lim; Kim, Bo-Been
2017-07-01
Levator scapulae (LS) muscle stretching exercises are a common method of lengthening a shortened muscle; however, the appropriate stretching position for lengthening the LS in people with a shortened LS remains unclear. The purpose of this study was to compare the effects of different stretching exercise positions on the LS and introduce effective stretching exercise methods to clinicians. Twenty-four university students (12 men, 12 women) with a shortened LS were recruited. LS muscle activity, LS index (LSI), and cervical range of motion (ROM) were measured pre (baseline) and post three different stretching exercise positions (sitting, quadruped, and prone). The LSI and cervical ROM exceeded the minimal detectable change and had significant changes. The LSI was greater in the sitting position than at the baseline (p = 0.01), quadruped position (p < 0.01); the LSI in the prone position presented a higher increase than the quadruped position (p = 0.01). The cervical ROM increased in the sitting position when compared to the baseline (p < 0.01) and quadruped position (p < 0.01). Stretching the LS in the sitting position was the most effective exercise for improving LS muscle length and cervical ROM. Copyright © 2017 Elsevier Ltd. All rights reserved.
Role of pelvic floor in lower urinary tract function.
Chermansky, Christopher J; Moalli, Pamela A
2016-10-01
The pelvic floor plays an integral part in lower urinary tract storage and evacuation. Normal urine storage necessitates that continence be maintained with normal urethral closure and urethral support. The endopelvic fascia of the anterior vaginal wall, its connections to the arcus tendineous fascia pelvis (ATFP), and the medial portion of the levator ani muscles must remain intact to provide normal urethral support. Thus, normal pelvic floor function is required for urine storage. Normal urine evacuation involves a series of coordinated events, the first of which involves complete relaxation of the external urethral sphincter and levator ani muscles. Acquired dysfunction of these muscles will initially result in sensory urgency and detrusor overactivity; however, with time the acquired voiding dysfunction can result in intermittent urine flow and incomplete bladder emptying, progressing to urinary retention in severe cases. This review will start with a discussion of normal pelvic floor anatomy and function. Next various injuries to the pelvic floor will be reviewed. The dysfunctional pelvic floor will be covered subsequently, with a focus on levator ani spasticity and stress urinary incontinence (SUI). Finally, future research directions of the interaction between the pelvic floor and lower urinary tract function will be discussed. Copyright © 2015 Elsevier B.V. All rights reserved.
What’s new in the functional anatomy of pelvic organ prolapse?
DeLancey, John O. L.
2017-01-01
Purpose of Review Provide an evidence-based review of pelvic floor functional anatomy related to pelvic organ prolapse. Recent Findings Pelvic organ support depends on interactions between the levator ani muscle and pelvic connective tissues. Muscle failure exposes the vaginal wall a pressure differential producing abnormal tension on the attachments of the pelvic organs to the pelvic side-wall. Birth-induced injury to the pubococcygeal portion of the levator ani muscle is seen in 55% of women with prolapse and 16% of women with normal support. Failure of the connective tissue attachments between the uterus and vagina to the pelvic wall (cardinal, uterosacral, paravaginal) are strongly related with prolapse (effect sizes ~2.5) and are also highly correlated with one another (r ~0.85). Small differences exist with prolapse in factors involving the vaginal wall length and width (effect sizes ~1). The primary difference in ligament properties between women with and without prolapse is found in ligament length. Only minor differences in ligament stiffness are seen. Summary Pelvic organ prolapse occurs due to injury to the levator ani muscles and failure of the connections between the pelvic organs to the pelvic sidewall. Abnormalities of the vaginal wall fascial tissues may play a minor role. PMID:27517338
Shek, K L; Guzman-Rojas, R; Dietz, H P
2014-12-01
Obstetric anal sphincter tears are common and an important factor in the etiology of anal incontinence. The objective of the study was to evaluate the prevalence of residual defects of the external anal sphincter (EAS) after primary repair of obstetric anal sphincter injury using four-dimensional (4D) transperineal ultrasound and to correlate sonographic findings of residual defects and levator avulsion with significant symptoms of anal incontinence, defined as St Mark's fecal incontinence score (SMIS) of ≥ 5. This was a retrospective observational study. One-hundred and forty women were seen after primary repair of obstetric anal sphincter tears in a dedicated perineal clinic at a tertiary hospital in Australia. They all underwent a standardized interview, and physical and 4D transperineal ultrasound examination. Mean follow-up interval was 1.9 months after delivery. Eighty-nine (64%) women had a 3a/3b tear, 28 (20%) a 3c/4(th) degree tear and 23 (16%) an unclassified 3(rd) degree tear. Thirty-five (25%) patients reported symptoms of anal incontinence. Nine had an SMIS of ≥ 5. A residual defect was found in 56 (40%) cases and levator avulsion in 27 (19%). On multivariate logistic regression, residual defects (P = 0.03; odds ratio (OR) = 6.38; 95% CI, 1.23-33.0) and levator avulsion (P = 0.047; OR = 4.38; 95% CI, 1.02-18.77) were found to be independent risk factors for anal incontinence. Residual defects of the EAS were found on transperineal ultrasound in 40% of women after primary repair of obstetric anal sphincter injuries. Although most were asymptomatic, residual anal sphincter defects and levator avulsion were associated with significant symptoms of anal incontinence as quantified using the SMIS. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Muscle complex saving posterior sagittal anorectoplasty.
Zaiem, Maher; Zaiem, Feras
2017-05-01
Posterior sagittal anorectoplasty (PSARP) published by DeVries and Peña in 1982 had become the preferred surgical technique for the management of anorectal malformations (ARM). The original technique is based upon complete exposure of the anorectal region by means of a median sagittal incision that runs from the sacrum to the anal dimple, cutting through all muscle structures behind the rectum by dividing the levator muscle and the muscle complex. Then, the rectum is located in front of the levator and within the limits of the muscle complex. In this review, we described Muscle Complex Saving-Posterior Sagittal Anorectoplasty (MCS-PSARP), which is a less invasive technique that consists of keeping this funnel-shaped muscle complex completely intact and not divided, and pulling the rectum through this funnel, toward fixing the new anus to the skin. This technique aimed both to respect the lower part of the sphincter mechanism consisting of the muscle complex, and to avoid the disturbance of this important structure by dividing and resuturing it. We presented six cases of male patients who were born with anorectal malformation (ARM) and underwent MCS-PSARP. The surgical technique proved to be feasible to achieve the dissection of the rectal pouch and the division of the rectourethral fistula in all patients, by opening only the upper part of the sphincter mechanism, the levator muscle, and keeping the lower part consisting of intact muscle complex. The early results in our series are encouraging; however, long-term functional outcomes of these patients are awaited. The surgical tips were also discussed. This proposed approach in the management of anorectal malformation cases provides an opportunity to maximize preservation of the existing continence mechanisms. It preserves the muscle complex components of the levator muscle intact, allowing a better function of the continence mechanism. Copyright © 2016 Elsevier Inc. All rights reserved.
Alternative S2 Hinge Regions of the Myosin Rod Affect Myofibrillar Structure and Myosin Kinetics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Mark S.; Dambacher, Corey M.; Knowles, Aileen F.
2009-07-01
The subfragment 2/light meromyosin 'hinge' region has been proposed to significantly contribute to muscle contraction force and/or speed. Transgenic replacement of the endogenous fast muscle isovariant hinge A (exon 15a) in Drosophila melanogaster indirect flight muscle with the slow muscle hinge B (exon 15b) allows examination of the structural and functional changes when only this region of the myosin molecule is different. Hinge B was previously shown to increase myosin rod length, increase A-band and sarcomere length, and decrease flight performance compared to hinge A. We applied additional measures to these transgenic lines to further evaluate the consequences of modifyingmore » this hinge region. Structurally, the longer A-band and sarcomere lengths found in the hinge B myofibrils appear to be due to the longitudinal addition of myosin heads. Functionally, hinge B, although a significant distance from the myosin catalytic domain, alters myosin kinetics in a manner consistent with this region increasing myosin rod length. These structural and functional changes combine to decrease whole fly wing-beat frequency and flight performance. Our results indicate that this hinge region plays an important role in determining myosin kinetics and in regulating thick and thin filament lengths as well as sarcomere length.« less
Polymorphic design of DNA origami structures through mechanical control of modular components.
Lee, Chanseok; Lee, Jae Young; Kim, Do-Nyun
2017-12-12
Scaffolded DNA origami enables the bottom-up fabrication of diverse DNA nanostructures by designing hundreds of staple strands, comprised of complementary sequences to the specific binding locations of a scaffold strand. Despite its exceptionally high design flexibility, poor reusability of staples has been one of the major hurdles to fabricate assorted DNA constructs in an effective way. Here we provide a rational module-based design approach to create distinct bent shapes with controllable geometries and flexibilities from a single, reference set of staples. By revising the staple connectivity within the desired module, we can control the location, stiffness, and included angle of hinges precisely, enabling the construction of dozens of single- or multiple-hinge structures with the replacement of staple strands up to 12.8% only. Our design approach, combined with computational shape prediction and analysis, can provide a versatile and cost-effective procedure in the design of DNA origami shapes with stiffness-tunable units.
Weng, Pei-Wei; Chen, Chia-Hsien; Luo, Chu-An; Sun, Jui-Sheng; Tsuang, Yang-Hwei; Cheng, Cheng-Kung; Lin, Shang-Chih
2017-04-01
Several plate systems for high tibial osteotomy (HTO) have been developed to stabilize the opening wedge of an osteotomized tibia. Among them, the TomoFix system, having a quasi-straight and T-shaped design, has been widely adopted in the literature. However, this system is implemented by inserting a lag (i.e., cortical) screw through the proximal combi-hole, to deform the plate and pull the distal tibia toward the plate. This process potentially induces plate springback and creates an elastic preload on the osteotomized tibia, especially at the lateral hinge of the distracted wedge. Using the finite-element method, this study aims to investigate the contoured effect of lag-screw application on the biomechanical behavior of the tibia-plate construct. Two tibial profiles (normal and more concave), three distraction angles (6°, 9°, and 12°), and three knee loads (intraoperative: contouring plate; postoperative: weight and nonweight bearing) are systematically varied in this study. The wedge instability and fracture risk at the lateral hinge are chosen as the comparison indices. The results show the necessity of preoperative planning for a precontoured procedure, rather than elastic deformation using a lag screw. Within the intraoperative period, a more concave tibial profile and/or reduced distraction angle (i.e., 6° or 9°) necessitate a higher compressive load to elastically deform the plate, thereby deteriorating the lateral-hinge fracture risk. A precontoured plate is recommended in the case that the proximal tibia is highly concave and the distraction angle is insufficient to stretch the tibial profile. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Chauhan, Aakash; Palmer, Bradley A; Baratz, Mark E
2015-06-01
Total elbow arthroplasty is successful in older, lower demand patients but not in the younger, more active individual with severe elbow arthritis. Interposition arthroplasty is an alternative for younger patients who hope to minimize the degree to which arm use is restricted. Interposition arthroplasty traditionally involves release of all ligaments and capsule. As a result, the postoperative care included the use of a hinged external fixator of the elbow to apply distraction and to permit motion during the early phases of healing. We describe a novel surgical technique without a hinged external fixator that allows secure fixation of the interposition graft through arthroscopic assistance and maintains the integrity of the medial collateral ligament with only a takedown and repair of the lateral collateral ligament complex. A retrospective chart review was performed to analyze 4 patients with an average age of 57 years who underwent surgery between 2007 and 2011. The patients were also contacted to assess elbow-specific American Shoulder and Elbow Surgeons and Disabilities of the Arm, Shoulder, and Hand scores. The average follow-up was 3.6 years (range, 2.5-6 years), and 1 patient was converted to a total elbow arthroplasty after 2.5 years because of persistent pain. The remaining 3 patients have done well with regard to pain control, stability, and functional use of the operative extremity. There were no postoperative complications. On the basis of our small series of patients, an arthroscopically assisted elbow interposition arthroplasty without hinged external fixation can provide satisfactory medium-term outcomes as a salvage procedure for a difficult condition with limited options. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Recursive Newton-Euler formulation of manipulator dynamics
NASA Technical Reports Server (NTRS)
Nasser, M. G.
1989-01-01
A recursive Newton-Euler procedure is presented for the formulation and solution of manipulator dynamical equations. The procedure includes rotational and translational joints and a topological tree. This model was verified analytically using a planar two-link manipulator. Also, the model was tested numerically against the Walker-Orin model using the Shuttle Remote Manipulator System data. The hinge accelerations obtained from both models were identical. The computational requirements of the model vary linearly with the number of joints. The computational efficiency of this method exceeds that of Walker-Orin methods. This procedure may be viewed as a considerable generalization of Armstrong's method. A six-by-six formulation is adopted which enhances both the computational efficiency and simplicity of the model.
Thin film solar cell inflatable ultraviolet rigidizable deployment hinge
NASA Technical Reports Server (NTRS)
Simburger, Edward J. (Inventor); Giants, Thomas W. (Inventor); Perry, Alan R. (Inventor); Rawal, Suraj (Inventor); Lin, John K. H. (Inventor); Matsumoto, James H. (Inventor); Garcia, III, Alec (Inventor); Marshall, Craig H. (Inventor); Day, Jonathan Robert (Inventor); Kerslake, Thomas W. (Inventor)
2010-01-01
A flexible inflatable hinge includes curable resin for rigidly positioning panels of solar cells about the hinge in which wrap around contacts and flex circuits are disposed for routing power from the solar cells to the power bus further used for grounding the hinge. An indium tin oxide and magnesium fluoride coating is used to prevent static discharge while being transparent to ultraviolet light that cures the embedded resin after deployment for rigidizing the inflatable hinge.
Fujita, Kenya; Matsuo, Kiyoshi; Yuzuriha, Shunsuke
2013-01-01
Introduction: We have previously reported that fascia lata grafts with peritendinous areolar tissue used to treat severe congenital blepharoptosis gradually shrink within 6 weeks postoperatively and maintain long-term shrinkage of 15.5% on average. Accordingly, it seemed possible that a fascia lata graft without peritendinous areolar tissue would shrink more than the one with peritendinous areolar tissue in a clinical setting. We evaluated this possibility in a patient with Klippel-Feil syndrome having postoperative deep atonic nasopharynx. Methods: In combination with intravelar veloplasty and palatal lengthening with modified bilateral buccinator sandwich pushback, a ringed fascia lata without peritendinous areolar tissue encircling the levator veli palatini and superior constrictor muscles was grafted to cure severe velopharyngeal incompetence. Results: Obstructive sleep apnea did not occur following surgery. Pharyngoscopy, videofluoroscopy, and nasometry showed no amelioration of velopharyngeal incompetence at 1 month postoperatively, but marked velopharyngeal incompetence reduction was evident at 4 months and 2 years after surgery. Conclusions: The extended recovery period suggests that the anticipated postoperative shrinkage of the ringed fascia lata without peritendinous areolar tissue played a more prominent role than intravelar veloplasty and palatal lengthening, which posteroinferiorly elongated the atonic soft palate. Although the pharyngeal flap procedure is the most popular technique for treatment of velopharyngeal incompetence, it is sometimes accompanied by respiratory complications. Thus, the gradual postoperative shrinkage of a ringed fascia lata graft encircling the velopharyngeal muscles functions as an intravelar palatal lift and may be an additional surgical method with less respiratory complications to narrow atonic nasopharyngeal port. PMID:23814637
Haavik, Heidi; Murphy, Bernadette A; Kruger, Jennifer
2016-06-01
The aim of this study was to investigate whether a single session of spinal manipulation of pregnant women can alter pelvic floor muscle function as measured using ultrasonographic imaging. In this preliminary, prospective, comparative study, transperineal ultrasonographic imaging was used to assess pelvic floor anatomy and function in 11 primigravid women in their second trimester recruited via notice boards at obstetric caregivers, pregnancy keep-fit classes, and word of mouth and 15 nulliparous women recruited from a convenience sample of female students at the New Zealand College of Chiropractic. Following bladder voiding, 3-/4-dimensional transperineal ultrasonography was performed on all participants in the supine position. Levator hiatal area measurements at rest, on maximal pelvic floor contraction, and during maximum Valsalva maneuver were collected before and after either spinal manipulation or a control intervention. Levator hiatal area at rest increased significantly (P < .05) after spinal manipulation in the pregnant women, with no change postmanipulation in the nonpregnant women at rest or in any of the other measured parameters. Spinal manipulation of pregnant women in their second trimester increased the levator hiatal area at rest and thus appears to relax the pelvic floor muscles. This did not occur in the nonpregnant control participants, suggesting that it may be pregnancy related. Copyright © 2016. Published by Elsevier Inc.
Deployment hinge using wraparound strips
NASA Technical Reports Server (NTRS)
Blanc, Eric
1992-01-01
Aerospatiale developed a new appendage deployment concept called AMEDE (French acronym for improvement of deployment mechanisms) with a view toward increased simplicity and functional reliability. This new concept, applicable to the deployment of any type of spaceborne appendage (in particular to solar arrays), enables deployment without synchronization or speed regulation devices. On the other hand, it requires the use of hinges with low driving or resistive torques. The AMEDE concept is compared with the conventional deployment concept. The conceptual and functional principles for the ADELE hinge are presented, as well as the hinges' main characteristics. The development status of both the AMEDE concept and the ADELE (French acronym for deployment hinge using wraparound strips) hinge are addressed.
Note: Design and capability verification of fillet triangle flexible support
NASA Astrophysics Data System (ADS)
Wang, Tao; San, Xiao-Gang; Gao, Shi-Jie; Wang, Jing; Ni, Ying-Xue; Sang, Zhi-Xin
2017-12-01
By increasing the section thickness of a triangular flexible hinge, this study focuses on optimal selection of parameters of fillet triangle flexible hinges and flexible support. Based on Castigliano's second theorem, the flexibility expression of the fillet triangle flexible hinge was derived. Then, the case design is performed, and the comparison of three types of flexible hinges with this type of flexible hinge was carried out. The finite element models of fillet triangle flexible hinges and flexible support were built, and then the simulation results of performance parameters were calculated. Finally, the experiment platform was established to validate analysis results. The maximum error is less than 8%, which verifies the accuracy of the simulation process and equations derived; also the fundamental frequency fits the requirements of the system. The fillet triangle flexible hinge is proved to have the advantages of high precision and low flexibility.
Note: Design and capability verification of fillet triangle flexible support.
Wang, Tao; San, Xiao-Gang; Gao, Shi-Jie; Wang, Jing; Ni, Ying-Xue; Sang, Zhi-Xin
2017-12-01
By increasing the section thickness of a triangular flexible hinge, this study focuses on optimal selection of parameters of fillet triangle flexible hinges and flexible support. Based on Castigliano's second theorem, the flexibility expression of the fillet triangle flexible hinge was derived. Then, the case design is performed, and the comparison of three types of flexible hinges with this type of flexible hinge was carried out. The finite element models of fillet triangle flexible hinges and flexible support were built, and then the simulation results of performance parameters were calculated. Finally, the experiment platform was established to validate analysis results. The maximum error is less than 8%, which verifies the accuracy of the simulation process and equations derived; also the fundamental frequency fits the requirements of the system. The fillet triangle flexible hinge is proved to have the advantages of high precision and low flexibility.
Concealed hinge permits flush mounting of doors and hatches
NASA Technical Reports Server (NTRS)
Holman, E. V.
1966-01-01
Hinge assembly permits flush mounting of doors and hatches of considerable thickness so that the axis of instant rotation, produced by the hinge, lies outside the panel surface and beyond the perimeter adjacent to the hinge. In operation, motion of the assembly is initially parallel, changing to angular after clearing the panel perimeter.
Nakamura, R; Komatsu, N; Fujita, K; Kuroda, K; Takahashi, M; Omi, R; Katsuki, Y; Tsuchiya, H
2017-10-01
Open wedge high tibial osteotomy (OWHTO) for medial-compartment osteoarthritis of the knee can be complicated by intra-operative lateral hinge fracture (LHF). We aimed to establish the relationship between hinge position and fracture types, and suggest an appropriate hinge position to reduce the risk of this complication. Consecutive patients undergoing OWHTO were evaluated on coronal multiplanar reconstruction CT images. Hinge positions were divided into five zones in our new classification, by their relationship to the proximal tibiofibular joint (PTFJ). Fractures were classified into types I, II, and III according to the Takeuchi classification. Among 111 patients undergoing OWHTOs, 22 sustained lateral hinge fractures. Of the 89 patients without fractures, 70 had hinges in the zone within the PTFJ and lateral to the medial margin of the PTFJ (zone WL), just above the PTFJ. Among the five zones, the relative risk of unstable fracture was significantly lower in zone WL (relative risk 0.24, confidence interval 0.17 to 0.34). Zone WL appears to offer the safest position for the placement of the osteotomy hinge when trying to avoid a fracture at the osteotomy site. Cite this article: Bone Joint J 2017;99B10:1313-18. ©2017 The British Editorial Society of Bone & Joint Surgery.
Multifunctional Deployment Hinges Rigidified by Ultraviolet
NASA Technical Reports Server (NTRS)
Kerslake, Thomas W.; Simburger, Edward J.; Matusmoto, James; Giants, Thomas W.; Garcia, Alexander; Perry, Alan; Rawal, Suraj; Marshall, Craig; Lin, John Kun Hung; Day, Jonathan Robert;
2005-01-01
Multifunctional hinges have been developed for deploying and electrically connecting panels comprising planar arrays of thin-film solar photovoltaic cells. In the original intended application of these hinges, the panels would be facets of a 32-sided (and approximately spherical) polyhedral microsatellite (see figure), denoted a PowerSphere, that would be delivered to orbit in a compact folded configuration, then deployed by expansion of gas in inflation bladders. Once deployment was complete, the hinges would be rigidified to provide structural connections that would hold the panels in their assigned relative positions without backlash. Such hinges could also be used on Earth for electrically connecting and structurally supporting solar panels that are similarly shipped in compact form and deployed at their destinations. As shown in section A-A in the figure, a hinge of this type is partly integrated with an inflation bladder and partly integrated with the frame of a solar panel. During assembly of the hinge, strip extensions from a flexible circuit harness on the bladder are connected to corresponding thin-film conductors on the solar panel by use of laser welding and wrap-around contacts. The main structural component of the hinge is a layer of glass fiber impregnated with an ultraviolet-curable resin. After deployment, exposure to ultraviolet light from the Sun cures the resin, thereby rigidifying the hinge.
Shi, Ze; Castro, Carlos E; Arya, Gaurav
2017-05-23
Structural DNA nanotechnology, the assembly of rigid 3D structures of complex yet precise geometries, has recently been used to design dynamic, mechanically compliant nanostructures with tunable equilibrium conformations and conformational distributions. Here we use coarse-grained molecular dynamics simulations to provide insights into the conformational dynamics of a set of mechanically compliant DNA nanostructures-DNA hinges that use single-stranded DNA "springs" to tune the equilibrium conformation of a layered double-stranded DNA "joint" connecting two stiff "arms" constructed from DNA helix bundles. The simulations reproduce the experimentally measured equilibrium angles between hinge arms for a range of hinge designs. The hinges are found to be structurally stable, except for some fraying of the open ends of the DNA helices comprising the hinge arms and some loss of base-pairing interactions in the joint regions coinciding with the crossover junctions, especially in hinges designed to exhibit a small bending angle that exhibit large local stresses resulting in strong kinks in their joints. Principal component analysis reveals that while the hinge dynamics are dominated by bending motion, some twisting and sliding of hinge arms relative to each other also exists. Forced deformation of the hinges reveals distinct bending mechanisms for hinges with short, inextensible springs versus those with longer, more extensible springs. Lastly, we introduce an approach for rapidly predicting equilibrium hinge angles from individual force-deformation behaviors of its single- and double-stranded DNA components. Taken together, these results demonstrate that coarse-grained modeling is a promising approach for designing, predicting, and studying the dynamics of compliant DNA nanostructures, where conformational fluctuations become important, multiple deformation mechanisms exist, and continuum approaches may not yield accurate properties.
Chronic perineal pain: current pathophysiological aspects, diagnostic approaches and treatment.
Andromanakos, Nikolaos P; Kouraklis, Grigorios; Alkiviadis, Kostakis
2011-01-01
Chronic perineal pain is the anorectal and perineal pain without underlying organic disease, anorectal or endopelvic, which has been excluded by careful physical examination, radiological and endoscopic investigations. A variety of neuromuscular disorders of the pelvic floor lead to the different pathological conditions such as anorectal incontinence, urinary incontinence and constipation of obstructed defecation, sexual dysfunction and pain syndromes. The most common functional disorders of the pelvic floor muscles, accompanied by perineal pain are levator ani syndrome, proctalgia fugax, myofascial syndrome and coccygodynia. In the diagnosis of these syndromes, contributing to a thorough history, physical examination, selected specialized investigations and the exclusion of organic disease with proctalgia is carried out. Accurate diagnosis of the syndromes helps in choosing an appropriate treatment and in avoiding unnecessary and ineffective surgical procedures, which often are performed in an attempt to alleviate the patient's symptoms.
Rojo, Isabel; Teixidor, Francesc; Viñas, Clara; Kivekäs, Raikko; Sillanpää, Reijo
2004-10-25
The anionic chelating ligand [1,1'-(PPh2)2-3,3'-Co(1,2-C2B9H10)2]- has been synthesized from [3,3'-Co(1,2-C2B9H11)2]- in very good yield in a one-pot process with an easy work-up procedure. The coordinating ability of this ligand has been studied with Group 11 metal ions (Ag, Au) and with transition-metal ions (Pd, Rh). The two dicarbollide halves of the [1,1'-(PPh2)2-3,3'-Co(1,2-C2B9H10)2]- ligand can swing about one axis in a manner analogous to the constituent parts of BINAP and ferrocenyl phosphine derivatives. All these ligands function as hinges, with the most important property in relation to the coordination requirements of the metal being the PP distance. [1,1'-(PPh2)2-3,3'-Co(1,2-C2B9H10)2]-, BINAP, ferrocenyl phosphine derivatives, and other hinge ligands present a range of different PP separations, and consequently different coordination spheres and dispositions around metal cations. To account for these differences, the equation Dphi2 = D02 + 4 R2cos2(90-phi/2) has been developed. It relates the PP distance (Dphi) in a complex with the minimum PP distance (D0) that is characteristic of the hinge-type ligand.
Controlling Flexible Robot Arms Using High Speed Dynamics Process
NASA Technical Reports Server (NTRS)
Jain, Abhinandan (Inventor)
1996-01-01
A robot manipulator controller for a flexible manipulator arm having plural bodies connected at respective movable hinges and flexible in plural deformation modes corresponding to respective modal spatial influence vectors relating deformations of plural spaced nodes of respective bodies to the plural deformation modes, operates by computing articulated body quantities for each of the bodies from respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables, and computing modal deformation accelerations and hinge accelerations is carried out for each one of the bodies beginning with the outermost body by computing a residual body force from a residual body force of a previous body and from the vector of deformation and hinge configuration variables, computing a resultant hinge acceleration from the body force, the residual body force and the articulated hinge inertia, and revising the residual body force modal body acceleration.
Controlling flexible robot arms using a high speed dynamics process
NASA Technical Reports Server (NTRS)
Jain, Abhinandan (Inventor); Rodriguez, Guillermo (Inventor)
1992-01-01
Described here is a robot controller for a flexible manipulator arm having plural bodies connected at respective movable hinges, and flexible in plural deformation modes. It is operated by computing articulated body qualities for each of the bodies from the respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables. Computing modal deformation accelerations and hinge accelerations is carried out for each of the bodies, beginning with the outermost body by computing a residual body force from a residual body force of a previous body, computing a resultant hinge acceleration from the body force, and then, for each one of the bodies beginning with the innermost body, computing a modal body acceleration from a modal body acceleration of a previous body, computing a modal deformation acceleration and hinge acceleration from the resulting hinge acceleration and from the modal body acceleration.
NASA Technical Reports Server (NTRS)
Wesselski, Clarence J. (Inventor)
1988-01-01
The space station configuration currently studied utilizes structures which require struts to be hinged in the middle in the stowed mode and locked into place in the deployed mode. Since there are hundreds of hinges involved, it is necessary that they have simple, positive locking features with a minimum of joint looseness or slack. This invention comprises two similar housings hinged together with a spring loaded locking member which assists in making as well as breaking the lock. This invention comprises a bracket hinge and bracket members with a spring biased and movable locking member. The locking or latch member has ear parts received in locking openings where wedging surfaces on the ear parts cooperate with complimentary surfaces on the bracket members for bringing the bracket members into a tight end-to-end alignment when the bracket members are in an extended position. When the locking member is moved to an unlocking position, pivoting of the hinge about a pivot pin automatically places the locking member to retain the locking member in an unlocked position. In pivoting the hinge from an extended position to a folded position, longitudinal spring members are placed under tension over annular rollers so that the spring tension in a folded position assists in return of the hinge from a folded to an extended position. Novelty lies in the creation of a locking hinge which allows compact storage and easy assembly of structural members having a minimal number of parts.
Deployment Testing of Flexible Composite Hinges in Bi-Material Beams
NASA Technical Reports Server (NTRS)
Sauder, Jonathan F.; Trease, Brian
2016-01-01
Composites have excellent properties for strength, thermal stability, and weight. However, they are traditionally highly rigid, and when used in deployable structures require hinges bonded to the composite material, which increases complexity and opportunities for failure. Recent research in composites has found by adding an elastomeric soft matrix, often silicone instead of an epoxy, the composite becomes flexible. This work explores the deployment repeatability of silicone matrix composite hinges which join rigid composite beams. The hinges were found to have sub-millimeter deployment repeatability. Also, an interesting creep effect was discovered, that a hinges deployment error would decrease with time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGinnis, J.P.; Karner, G.D.; Driscoll, N.W.
The tectonic and stratigraphic development of the Congo continental margin reflects the timing, magnitude, and distribution of lithospheric extension responsible for its formation. Details of the lithospheric extension process are recorded in the stratigraphic successions preserved along and across the margin. By using the stratal relationships (e.g., onlap, downlap, and truncation) and lithofacies determined from seismic reflection and exploratory well data as input into our basin-modeling strategy, we have developed an integrated approach to determine the relationship between the timing, magnitude, and distribution of lithospheric extension across the margin. Two hinge zones, an eastern and Atlantic hinge formed along themore » Congo margin in response to discrete extensional events occurring from the Berriasian to the Aptian. The eastern hinge zone demarcates the eastern limit of the broadly distributed Berriasian extension. This extension resulted in the formation of deep anoxic, lacustrine systems. In contrast, the Atlantic hinge, located [approximately]90 km west of the eastern hinge, marks the eastern limit of a second phase of extension, which began in the Hauterivian. Consequent footwall uplift and rotation exposed the earlier synrift and prerift stratigraphy to at least wave base causing varying amounts of erosional truncation across the Atlantic hinge zone along much of the Gabon, Congo, and Angola margins. The absence of the Melania Formation across the Congo margin implies that uplift of the Atlantic hinge was relatively minor compared to that across the Angola and Gabon margins. In addition, material eroded from the adjacent and topographically higher hinge zones may in part account for the thick wedge of sediment deposited seaward of the Congo Atlantic hinge. A third phase of extension reactivated both the eastern and Atlantic hinge zones and was responsible for creating the accommodation space for Marnes Noires source rock deposition.« less
Importance of the levator labii alaeque nasi muscle in dorsal septal deviations.
Tellioğlu, Ali Teoman; Özakpinar, Hülda Rifat; Cakir, Bariş; Tekdemir, Ibrahim
2011-03-01
Deviated cartilages structures of the nose can be affected by nasal muscles, and deviation becomes conspicuous when the patient smiles. This condition depends on activity of nasal muscles, particularly the levator labii alaeque nasi muscle. A total of 124 septorhinoplasty operations were performed to correct dorsal concave septal deviation between 2005 and 2009 years. The 70 women and 54 men included in the study had an average age of 28 years. The average follow-up period was 12 months. Open septorhinoplasty was preferred in all cases. The medial part of the levator labii alaeque nasi muscle was extensively dissected from the lateral crus and surrounding tissues. The lateral crura of the alar cartilages were separated from the upper lateral cartilages in the scroll area. The dorsal septal deviation was corrected by combination of bilateral spreader grafts, which reinforced cartilage with horizontal control sutures. Early postoperative period was uneventful. Nasal obstruction was reduced after surgery, and significant subjective postoperative improvements were observed in all patients. Comparison of preoperative and postoperative photographs demonstrated improved dorsal nasal contour. Revision operation was performed in 3 cases. The corrected septal cartilage was in a good position in all revised cases; therefore, septal surgery was not performed in the revision operations. In conclusion, surgical disruption of the anatomic relationship between the muscle with the dorsal septal cartilage and reinforcement of the dorsal septal cartilage with spreader grafts and horizontal control sutures can decrease risk of recurrence.
Does fibromyalgia influence symptom bother from pelvic organ prolapse?
Adams, Kerrie; Osmundsen, Blake; Gregory, W Thomas
2014-05-01
Determine if women with fibromyalgia report increased bother from pelvic organ prolapse compared with women without fibromyalgia. We performed a cross-sectional study of women with symptomatic prolapse on consultation with a private urogynecology practice within a 46-month period. After matching for age, women with a diagnosis of fibromyalgia were compared with a reference group of women without fibromyalgia. Demographic, POPQ examination, medical history, and pelvic floor symptom data (PFDI, PFIQ, and PISQ-12) were collected. Our primary outcome was to compare the mean Pelvic Floor Distress Inventory (PFDI) scores of women with and without fibromyalgia. The prevalence of fibromyalgia in women evaluated for initial urogynecology consultation during the study period was 114 out of 1,113 (7%). Women with fibromyalgia reported significantly higher symptom bother scores related to pelvic organ prolapse, defecatory dysfunction, urinary symptoms, and sexual function: PFDI (p = 0.005), PFIQ (p=0.010), and PISQ (p=0.018). Women with fibromyalgia were found to have a higher BMI (p=0.008) and were more likely to report a history of sexual abuse, OR 3.1 (95 % CI 1.3, 7.9), and have levator myalgia on examination, OR 3.8 (95% CI 1.5, 9.1). In a linear regression analysis, levator myalgia was found to be the significant factor associated with pelvic floor symptom bother. In women with symptomatic prolapse, fibromyalgia is associated with an increased risk of levator myalgia and 50% more symptom bother from pelvic floor disorders.
Creep and cracking of concrete hinges: insight from centric and eccentric compression experiments.
Schlappal, Thomas; Schweigler, Michael; Gmainer, Susanne; Peyerl, Martin; Pichler, Bernhard
2017-01-01
Existing design guidelines for concrete hinges consider bending-induced tensile cracking, but the structural behavior is oversimplified to be time-independent. This is the motivation to study creep and bending-induced tensile cracking of initially monolithic concrete hinges systematically. Material tests on plain concrete specimens and structural tests on marginally reinforced concrete hinges are performed. The experiments characterize material and structural creep under centric compression as well as bending-induced tensile cracking and the interaction between creep and cracking of concrete hinges. As for the latter two aims, three nominally identical concrete hinges are subjected to short-term and to longer-term eccentric compression tests. Obtained material and structural creep functions referring to centric compression are found to be very similar. The structural creep activity under eccentric compression is significantly larger because of the interaction between creep and cracking, i.e. bending-induced cracks progressively open and propagate under sustained eccentric loading. As for concrete hinges in frame-like integral bridge construction, it is concluded (i) that realistic simulation of variable loads requires consideration of the here-studied time-dependent behavior and (ii) that permanent compressive normal forces shall be limited by 45% of the ultimate load carrying capacity, in order to avoid damage of concrete hinges under sustained loading.
Control surface hinge moment prediction using computational fluid dynamics
NASA Astrophysics Data System (ADS)
Simpson, Christopher David
The following research determines the feasibility of predicting control surface hinge moments using various computational methods. A detailed analysis is conducted using a 2D GA(W)-1 airfoil with a 20% plain flap. Simple hinge moment prediction methods are tested, including empirical Datcom relations and XFOIL. Steady-state and time-accurate turbulent, viscous, Navier-Stokes solutions are computed using Fun3D. Hinge moment coefficients are computed. Mesh construction techniques are discussed. An adjoint-based mesh adaptation case is also evaluated. An NACA 0012 45-degree swept horizontal stabilizer with a 25% elevator is also evaluated using Fun3D. Results are compared with experimental wind-tunnel data obtained from references. Finally, the costs of various solution methods are estimated. Results indicate that while a steady-state Navier-Stokes solution can accurately predict control surface hinge moments for small angles of attack and deflection angles, a time-accurate solution is necessary to accurately predict hinge moments in the presence of flow separation. The ability to capture the unsteady vortex shedding behavior present in moderate to large control surface deflections is found to be critical to hinge moment prediction accuracy. Adjoint-based mesh adaptation is shown to give hinge moment predictions similar to a globally-refined mesh for a steady-state 2D simulation.
NASA Astrophysics Data System (ADS)
Mailen, Russell W.; Dickey, Michael D.; Genzer, Jan; Zikry, Mohammed
2017-11-01
Shape memory polymer (SMP) sheets patterned with black ink hinges change shape in response to external stimuli, such as absorbed thermal energy from an infrared (IR) light. The geometry of these hinges, including size, orientation, and location, and the applied thermal loads significantly influence the final folded shape of the sheet, but these variables have not been fully investigated. We perform a systematic study on SMP sheets to fundamentally understand the effects of single and double hinge geometries, hinge orientation and spacing, initial temperature, heat flux intensity, and pattern width on the folding behavior. We have developed thermo-viscoelastic finite element models to characterize and quantify the stresses, strains, and temperatures as they relate to SMP shape changes. Our predictions indicate that hinge orientation can be used to reduce the total bending angle, which is the angle traversed by the folding face of the sheet. Two parallel hinges increase the total bending angle, and heat conduction between the hinges affects the transient folding response. IR intensity and initial temperatures can also influence the transient folding behavior. These results can provide guidelines to optimize the transient folding response and the three-dimensional folded structure obtained from self-folding polymer origami sheets that can be applied for myriad applications.
Deployment Testing of Flexible Composite Hinges in Bi-Material Beams
NASA Technical Reports Server (NTRS)
Sauder, Jonathan F.; Trease, Brian
2016-01-01
Composites have excellent properties for strength, thermal stability, and weight. However, they are traditionally highly rigid, and when used in deployable structures require hinges bonded to the composite material, which increases complexity and opportunities for failure. Recent research in composites has found by adding an elastomeric soft matrix, often silicone instead of an epoxy, the composite becomes flexible. This work explores the deployment repeatability of silicone matrix composite hinges which join rigid composite beams. The hinges were found to have sub-millimeter linear deployment repeatability, and sub-degree angular deployment repeatability. Also, an interesting relaxation effect was discovered, as a hinges deployment error would decrease with time.
Apparatus Producing an Even Distribution of Strain into Carries
NASA Astrophysics Data System (ADS)
Hrabovský, Leopold
2017-10-01
In many high-rise residential buildings or multi-storey warehouses, machinery, so called lifts, is used for the vertical transportation of people or weights between two or more altitudinally distant places. Carriers used for lifts are steel ropes or sprocket chains, on which a cage or a counterbalance is hinged. Apparatus of all carriers, attached to the hinge of the cage or counterbalance, should be even. This can be made only by hammer hinge. Fixed or springe hinge cannot be a perfect equalizing apparatus. This article describes an apparatus, which allows an even distribution of the strain into lift carriers, which use springe hinge of carrier ropes.
Mian, Shahzad I; Li, Amy Y; Dutta, Satavisha; Musch, David C; Shtein, Roni M
2009-12-01
To determine whether corneal sensation and dry-eye signs and symptoms after myopic laser in situ keratomileusis (LASIK) surgery with a femtosecond laser are affected by varying hinge position, hinge angle, or flap thickness. University-based academic practice, Ann Arbor, Michigan, USA. This prospective randomized contralateral-eye study evaluated eyes after bilateral myopic LASIK with a femtosecond laser (IntraLase). Superior and temporal hinge positions, 45-degree and 90-degree hinge angles, and 100 microm and 130 microm corneal flap thicknesses were compared. Postoperative follow-up at 1 week and 1, 3, 6, and 12 months included central Cochet-Bonnet esthesiometry, the Ocular Surface Disease Index questionnaire, a Schirmer test with anesthesia, tear breakup time (TBUT), corneal fluorescein staining, and conjunctival lissamine green staining. The study evaluated 190 consecutive eyes (95 patients). Corneal sensation was reduced at all postoperative visits, with improvement over 12 months (P<.001). There was no difference in corneal sensation between the different hinge positions, angles, or flap thicknesses at any time point. The overall ocular surface disease index score was increased at 1 week, 1 month, and 3 months (P<.0001, P<.0001, and P = .046, respectively). The percentage of patients with a TBUT longer than 10 seconds was significantly lower at 1 week and 1 month (P<.0001). Dry-eye syndrome after myopic LASIK with a femtosecond laser was mild and improved after 3 months. Corneal flap hinge position, hinge angle, and thickness had no effect on corneal sensation or dry-eye syndrome.
Device serves as hinge and electrical connector for circuit boards
NASA Technical Reports Server (NTRS)
Bethel, P. G.; Harris, G. G.
1966-01-01
Hinge makes both sides of electrical circuit boards readily accessible for component checkout and servicing. The hinge permits mounting of two circuit boards and incorporates connectors to maintain continuous electrical contact between the components on both boards.
Hinge Moment Coefficient Prediction Tool and Control Force Analysis of Extra-300 Aerobatic Aircraft
NASA Astrophysics Data System (ADS)
Nurohman, Chandra; Arifianto, Ony; Barecasco, Agra
2018-04-01
This paper presents the development of tool that is applicable to predict hinge moment coefficients of subsonic aircraft based on Roskam’s method, including the validation and its application to predict hinge moment coefficient of an Extra-300. The hinge moment coefficients are used to predict the stick forces of the aircraft during several aerobatic maneuver i.e. inside loop, half cuban 8, split-s, and aileron roll. The maximum longitudinal stick force is 566.97 N occurs in inside loop while the maximum lateral stick force is 340.82 N occurs in aileron roll. Furthermore, validation hinge moment prediction method is performed using Cessna 172 data.
... Pill Identifier Commonly searched drugs Aspirin Metformin Warfarin Tramadol Lactulose Ranitidine News & Commentary Recent News Afib and Weight AHA: Using Electricity to Test Your Risk for Heart Failure Close Siblings Can Ease the Pain of Family Conflict Don't Turn Into a ...
Dungan, C F; Elston, R A; Schiewe, M H
1989-01-01
Several strains of cytophaga-like gliding bacteria (CLB) were isolated as numerically dominant or codominant components of bacterial populations associated with proteinaceous hinge ligaments of cultured juvenile Pacific oysters, Crassostrea gigas. These bacteria were morphologically similar to long, flexible bacilli occurring within degenerative lesions in oyster hinge ligaments. Among bacteria isolated from hinge ligaments, only CLB strains were capable of sustained growth with hinge ligament matrix as the sole source of organic carbon and nitrogen. In vitro incubation of cuboidal portions of ligament resilium with ligament CLB resulted in bacterial proliferation on the surfaces and penetration deep into ligament matrices. Bacterial proliferation was accompanied by loss of resilium structural and mechanical integrity, including complete liquefaction, at incubation temperatures between 10 and 20 degrees C. The morphological, distributional, and degradative characteristics of CLB isolated from oyster hinge ligaments provide compelling, albeit indirect, evidence that CLB are the agents of a degenerative disease affecting juvenile cultured oysters. The motility, metabolic, and hydrolytic characteristics of hinge ligament CLB and the low moles percent G + C values (32.4 to 32.9) determined for three representative strains indicate that they are marine Cytophaga spp. Images PMID:2757377
Dungan, C F; Elston, R A; Schiewe, M H
1989-05-01
Several strains of cytophaga-like gliding bacteria (CLB) were isolated as numerically dominant or codominant components of bacterial populations associated with proteinaceous hinge ligaments of cultured juvenile Pacific oysters, Crassostrea gigas. These bacteria were morphologically similar to long, flexible bacilli occurring within degenerative lesions in oyster hinge ligaments. Among bacteria isolated from hinge ligaments, only CLB strains were capable of sustained growth with hinge ligament matrix as the sole source of organic carbon and nitrogen. In vitro incubation of cuboidal portions of ligament resilium with ligament CLB resulted in bacterial proliferation on the surfaces and penetration deep into ligament matrices. Bacterial proliferation was accompanied by loss of resilium structural and mechanical integrity, including complete liquefaction, at incubation temperatures between 10 and 20 degrees C. The morphological, distributional, and degradative characteristics of CLB isolated from oyster hinge ligaments provide compelling, albeit indirect, evidence that CLB are the agents of a degenerative disease affecting juvenile cultured oysters. The motility, metabolic, and hydrolytic characteristics of hinge ligament CLB and the low moles percent G + C values (32.4 to 32.9) determined for three representative strains indicate that they are marine Cytophaga spp.
Evolution of the head-trunk interface in tetrapod vertebrates
Sefton, Elizabeth M; Bhullar, Bhart-Anjan S; Mohaddes, Zahra; Hanken, James
2016-01-01
Vertebrate neck musculature spans the transition zone between head and trunk. The extent to which the cucullaris muscle is a cranial muscle allied with the gill levators of anamniotes or is instead a trunk muscle is an ongoing debate. Novel computed tomography datasets reveal broad conservation of the cucullaris in gnathostomes, including coelacanth and caecilian, two sarcopterygians previously thought to lack it. In chicken, lateral plate mesoderm (LPM) adjacent to occipital somites is a recently identified embryonic source of cervical musculature. We fate-map this mesoderm in the axolotl (Ambystoma mexicanum), which retains external gills, and demonstrate its contribution to posterior gill-levator muscles and the cucullaris. Accordingly, LPM adjacent to the occipital somites should be regarded as posterior cranial mesoderm. The axial position of the head-trunk border in axolotl is congruent between LPM and somitic mesoderm, unlike in chicken and possibly other amniotes. DOI: http://dx.doi.org/10.7554/eLife.09972.001 PMID:27090084
Testosterone enhances C-14 2-deoxyglucose uptake by striated muscle. [sex hormones and muscle
NASA Technical Reports Server (NTRS)
Toop, J.; Max, S. R.
1982-01-01
The effect of testosterone propionate (TP) on C-14 2-deoxyglucose (C-14 2DG) uptake was studied in the rat levator ani muscle in vivo using the autoradiographic technique. Following a delay of 1 to 3 h after injecting TP, the rate of C-14 2DG uptake in experimental animals began to increase and continued to increase for at least 20 h. The label, which corresponds to C-14 2-deoxyglucose 6-phosphate, as demonstrated by chromatographic analysis of muscle extracts, was uniformly distributed over the entire muscle and was predominantly in muscle fibers, although nonmuscular elements were also labeled. The 1 to 3 h time lag suggests that the TP effect may be genomic, acting via androgen receptors, rather than directly on muscle membranes. Acceleration of glucose uptake may be an important early event in the anabolic response of the rat levator ani muscle to androgens.
Velopharyngeal closure and the longus capitis muscle.
Yamawaki, Y; Nishimura, Y; Suzuki, Y
1996-09-01
The dynamic mechanism of velopharyngeal function not only in normal individuals but also in patients with velopharyngeal insufficiency, which is mainly related to cleft palate, has been the subject of considerable interest and controversy. Recently, in order to clarify velopharyngeal movement in the valvular action on phonation we examined dynamic MR images of this area taken in the transverse plane in parallel with the muscle sling of levator veli palatini. In cases in whom the closure pattern in that plane is circular, detailed observation revealed a very interesting result; that is, the longus capitis muscle, one of the group of anterior vertebral muscles, is directly involved in velopharyngeal valving function. It has not previously been reported that the longus capitis muscle acts as one of the velopharyngeal closure muscles, in addition to levator veli palatini. The present study demonstrated that contraction of the muscle contributed to velopharyngeal closure by forward movement of the pharyngeal wall.
Explicit frequency equations of free vibration of a nonlocal Timoshenko beam with surface effects
NASA Astrophysics Data System (ADS)
Zhao, Hai-Sheng; Zhang, Yao; Lie, Seng-Tjhen
2018-02-01
Considerations of nonlocal elasticity and surface effects in micro- and nanoscale beams are both important for the accurate prediction of natural frequency. In this study, the governing equation of a nonlocal Timoshenko beam with surface effects is established by taking into account three types of boundary conditions: hinged-hinged, clamped-clamped and clamped-hinged ends. For a hinged-hinged beam, an exact and explicit natural frequency equation is obtained. However, for clamped-clamped and clamped-hinged beams, the solutions of corresponding frequency equations must be determined numerically due to their transcendental nature. Hence, the Fredholm integral equation approach coupled with a curve fitting method is employed to derive the approximate fundamental frequency equations, which can predict the frequency values with high accuracy. In short, explicit frequency equations of the Timoshenko beam for three types of boundary conditions are proposed to exhibit directly the dependence of the natural frequency on the nonlocal elasticity, surface elasticity, residual surface stress, shear deformation and rotatory inertia, avoiding the complicated numerical computation.
Parametric analysis and temperature effect of deployable hinged shells using shape memory polymers
NASA Astrophysics Data System (ADS)
Tao, Ran; Yang, Qing-Sheng; He, Xiao-Qiao; Liew, Kim-Meow
2016-11-01
Shape memory polymers (SMPs) are a class of intelligent materials, which are defined by their capacity to store a temporary shape and recover an original shape. In this work, the shape memory effect of SMP deployable hinged shell is simulated by using compiled user defined material subroutine (UMAT) subroutine of ABAQUS. Variations of bending moment and strain energy of the hinged shells with different temperatures and structural parameters in the loading process are given. The effects of the parameters and temperature on the nonlinear deformation process are emphasized. The entire thermodynamic cycle of SMP deployable hinged shell includes loading at high temperature, load carrying with cooling, unloading at low temperature and recovering the original shape with heating. The results show that the complicated thermo-mechanical deformation and shape memory effect of SMP deployable hinge are influenced by the structural parameters and temperature. The design ability of SMP smart hinged structures in practical application is prospected.
Real-Time Flight Envelope Monitoring System
NASA Technical Reports Server (NTRS)
Kerho, Michael; Bragg, Michael B.; Ansell, Phillip J.
2012-01-01
The objective of this effort was to show that real-time aircraft control-surface hinge-moment information could be used to provide a robust and reliable prediction of vehicle performance and control authority degradation. For a given airfoil section with a control surface -- be it a wing with an aileron, rudder, or elevator -- the control-surface hinge moment is sensitive to the aerodynamic characteristics of the section. As a result, changes in the aerodynamics of the section due to angle-of-attack or environmental effects such as icing, heavy rain, surface contaminants, bird strikes, or battle damage will affect the control surface hinge moment. These changes include both the magnitude of the hinge moment and its sign in a time-averaged sense, and the variation of the hinge moment with time. The current program attempts to take the real-time hinge moment information from the aircraft control surfaces and develop a system to predict aircraft envelope boundaries across a range of conditions, alerting the flight crew to reductions in aircraft controllability and flight boundaries.
Pelvic floor dysfunction--does menopause duration matter?
Trutnovsky, Gerda; Guzman-Rojas, Rodrigo; Martin, Andrew; Dietz, Hans P
2013-10-01
To explore the effect of menopause and hormone replacement therapy on pelvic organ prolapse and pelvic floor muscle function. The records of patients who attended a tertiary urogynaecological center were reviewed retrospectively. A standardised interview included menopausal age, i.e. years since last period or onset of menopausal symptoms, current or previous hormone use. The clinical examination included prolapse assessment (POP-Q) and palpation of the levator ani muscle. 4D transperineal ultrasound, supine and after voiding, was performed in all patients. Volume data sets were analysed for pelvic organ descent and measures of contractility and distensibility of the pelvic floor at a later date, blinded to all clinical data. Of 311 women seen during the inclusion period, 65% were postmenopausal. Current systemic or local hormone use was reported by 7% and 6%, respectively. 163 women (52%) reported prolapse symptoms with a mean bother of 5.7/10. Significant pelvic organ prolapse was found on clinical examination (POP-Q stage≥2) in 77%, and diagnosed on ultrasound in 61%. On multivariate analysis, controlling for calendaric age, parity and levator avulsion, there was no evidence for menopausal age as an independent predictor of any symptom and sign of pelvic organ prolapse and pelvic floor muscle function. Local oestrogen use and past or present hormone replacement therapy had no detectable effect on any pelvic floor parameter. Hormone deficiency following menopause is unlikely to play a major role in pelvic organ support and levator ani function. Hence, both do not appear to be substantially influenced by local or systemic hormone replacement therapy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Rader, Erik P; Cederna, Paul S; McClellan, William T; Caterson, Stephanie A; Panter, Kip E; Yu, Deborah; Buchman, Steven R; Larkin, Lisa M; Faulkner, John A; Weinzweig, Jeffrey
2008-03-01
Despite cleft palate repair, velopharyngeal competence is not achieved in approximately 15% of patients, often necessitating secondary surgical correction. Velopharyngeal competence postrepair may require the conversion of levator veli palatini muscle fibers from injury-susceptible type 2 fibers to injury-resistant type 1 fibers. As an initial step to determining the validity of this theory, we tested the hypothesis that, in most cases, repair induces the transformation to type 1 fibers, thus diminishing susceptibility to injury. Single permeabilized levator veli palatini muscle fibers were obtained from normal palates and nonrepaired congenitally-clefted palates of young (2 months old) and adult (14 to 15 months old) goats and from repaired palates of adult goats (8 months old). Repair was done at 2 months of age using a modified von Langenbeck technique. Fiber type was determined by contractile properties and susceptibility to injury was assessed by force deficit, the decrease in maximum force following a lengthening contraction protocol expressed as a percentage of initial force. For normal palates and cleft palates of young goats, the majority of the fibers were type 2 with force deficits of approximately 40%. Following repair, 80% of the fibers were type 1 with force deficits of 20% +/- 2%; these deficits were 45% of those for nonrepaired cleft palates of adult goats (p < .0001). The decrease in the percentage of type 2 fibers and susceptibility to injury may be important for the development of a functional levator veli palatini muscle postrepair.
Tamakawa, Mitsuharu; Murakami, Gen; Takashima, Ken; Kato, Tomoyasu; Hareyama, Masato
2003-12-01
We investigated the topographical anatomy of the pelvic fasciae and autonomic nerves using macroscopic slices of five decalcified female pelves. The lateral aspect of the supravaginal cervix uteri and superior-most vagina issued abundant thick fiber bundles. These visceral fibrous tissues extended dorsolaterally, joined another fibrous tissue from the rectum (the actual lateral ligament of the rectum) and attached to the parietal fibrous tissues at and around the sciatic foramina (i.e. the sacrospinous ligament, thick fasciae of the coccygeus and piriformis and dorsal end of the covering fascia of the levator ani). The inferior or ventral vagina also issued thick fiber bundles communicating with the levator ani fascia. This connection between the vagina and levator fascia, when stretched, seemed to provide a macroscopic morphology called the arcus tendineus fasciae pelvis. The overall morphology of the visceroparietal fascial bridge exhibited a bilateral wing-like shape. The fascial bridge complex was adjacent but dorso-inferior to the internal iliac vascular sheath and located slightly ventral to the pelvic splanchnic nerve. However, the pelvic plexus and its peripheral branches were embedded in the fascial complex. The hypogastric nerve ran along and beneath the uterosacral peritoneal fold, which did not contain thick fibrous tissue. During surgery, in combination with the superficially located vascular sheath, the morphology of the visceroparietal fascial bridge and associated nerves seemed to be artificially changed and developed into the so-called cardinal, uterosacral, uterovesical and/or rectal lateral ligaments. The classical and original concepts of these pelvic fascial structures may need to be altered to adjust to these surgical observations.
Bo, Chen; Ningbei, Yin
2014-01-01
Surgeons need references to undertake cleft lip repairs. We aimed to establish a three-dimensional model of upper lip muscles. We examined specimens from 2 adult cadaver heads and 8 adult cadaver lips, obtaining serial sections in the axial, sagittal, and coronal planes. Sections were stained to observe the philtrum, Cupid bow, vermilion, and nostril sill. Reconstruction was done with three-dimensional software (eg, 3D-DOCTOR, MicroMR). Parallel circular muscle fibers existed between modioli. The orbicularis oris deep layer contained fan muscle fibers inclining inward. Some ended at the anterior nasal crest. Others migrated to the depressor septum, crossed the midline, and migrated to the nasalis muscle. At the nostril floor, the depressor septum muscle bundle and ipsilateral orbicularis oris overlapped the nasalis muscle and the contralateral orbicularis oris. This construction shaped the nostril sill. The levator labii superioris alaeque nasi, levator labii superioris, and zygomaticus minor crossed the nasolabial groove and migrated to the superficial orbicularis oris, entering the outer edge of the nasal alar to the upper lip near the vermilion border and philtrum ridge, shaping Cupid bow. Contralateral deep orbicularis oris muscle fibers crossed the philtrum dimple to the lateral philtrum ridge (axial plane). Superficial reticular muscle fibers of the levator labii superioris, zygomaticus minor, zygomaticus major, and orbicularis oris inserted into the medial philtrum ridge (coronal plane). They intersected to form the philtrum ridge. A three-dimensional upper lip muscular system model was established that can be referenced for cleft lip repair and lip operations.
Ban, Ryokuya; Matsuo, Kiyoshi; Ban, Midori; Yuzuriha, Shunsuke
2013-01-01
The mixed levator and frontalis muscles lack the interior muscle spindles normally required to induce involuntary contraction of their slow-twitch fibers. To involuntarily move the eyelid and eyebrow, voluntary contraction of the levator nonskeletal fast-twitch muscle fibers stretches the mechanoreceptors in Müller's muscle to evoke trigeminal proprioception, which then induces reflex contraction of the levator and frontalis skeletal slow-twitch muscle fibers. The trigeminal proprioceptive nerve has a long intraorbital course from the mechanoreceptors in Müller's muscle to the superior orbital fissure. Since external force to the globe may cause impairment of trigeminal proprioceptive evocation, we confirmed how unilateral blowout fracture due to a hydraulic mechanism affects ipsilateral eyebrow movement as compared with unilateral zygomatic fracture. In 16 unilateral blowout fracture patients, eyebrow heights were measured on noninjured and injured sides in primary and 60° upward gaze and statistically compared. Eyebrow heights were also measured in primary gaze in 24 unilateral zygomatic fracture patients and statistically compared. In the blowout fracture patients, eyebrow heights on the injured side were significantly smaller than on the noninjured side in both gaze. In the zygomatic fracture patients, eyebrow heights on the injured side were significantly larger than on the noninjured side in primary gaze. Since 60° upward gaze did not recover the eyebrow ptosis observed in primary gaze in blowout fracture patients, such ptosis indicated impairment of trigeminal proprioceptive evocation and the presence of a hydraulic mechanism that may require ophthalmic examination.
Ban, Ryokuya; Matsuo, Kiyoshi; Ban, Midori; Yuzuriha, Shunsuke
2013-01-01
Objective: The mixed levator and frontalis muscles lack the interior muscle spindles normally required to induce involuntary contraction of their slow-twitch fibers. To involuntarily move the eyelid and eyebrow, voluntary contraction of the levator nonskeletal fast-twitch muscle fibers stretches the mechanoreceptors in Müller's muscle to evoke trigeminal proprioception, which then induces reflex contraction of the levator and frontalis skeletal slow-twitch muscle fibers. The trigeminal proprioceptive nerve has a long intraorbital course from the mechanoreceptors in Müller's muscle to the superior orbital fissure. Since external force to the globe may cause impairment of trigeminal proprioceptive evocation, we confirmed how unilateral blowout fracture due to a hydraulic mechanism affects ipsilateral eyebrow movement as compared with unilateral zygomatic fracture. Methods: In 16 unilateral blowout fracture patients, eyebrow heights were measured on noninjured and injured sides in primary and 60° upward gaze and statistically compared. Eyebrow heights were also measured in primary gaze in 24 unilateral zygomatic fracture patients and statistically compared. Results: In the blowout fracture patients, eyebrow heights on the injured side were significantly smaller than on the noninjured side in both gaze. In the zygomatic fracture patients, eyebrow heights on the injured side were significantly larger than on the noninjured side in primary gaze. Conclusion: Since 60° upward gaze did not recover the eyebrow ptosis observed in primary gaze in blowout fracture patients, such ptosis indicated impairment of trigeminal proprioceptive evocation and the presence of a hydraulic mechanism that may require ophthalmic examination. PMID:23814636
On the Stiffness of the Mesh and Urethral Mobility: A Finite Element Analysis.
Brandão, Sofia; Parente, Marco; Da Roza, Thuane Huyer; Silva, Elisabete; Ramos, Isabel Maria; Mascarenhas, Teresa; Natal Jorge, Renato Manuel
2017-08-01
Midurethral slings are used to correct urethral hypermobility in female stress urinary incontinence (SUI), defined as the complaint of involuntary urine leakage when the intra-abdominal pressure (IAP) is increased. Structural and thermal features influence their mechanical properties, which may explain postoperative complications, e.g., erosion and urethral obstruction. We studied the effect of the mesh stiffness on urethral mobility at Valsalva maneuver, under impairment of the supporting structures (levator ani and/or ligaments), by using a numerical model. For that purpose, we modeled a sling with "lower" versus "higher" stiffness and evaluated the mobility of the bladder and urethra, that of the urethrovesical junction (the α-angle), and the force exerted at the fixation of the sling. The effect of impaired levator ani or pubourethral ligaments (PUL) alone on the organs displacement and α-angle opening was similar, showing their important role together on urethral stabilization. When the levator ani and all the ligaments were simulated as impaired, the descent of the bladder and urethra went up to 25.02 mm, that of the bladder neck was 14.57 mm, and the α-angle was 129.7 deg, in the range of what was found in women with SUI. Both meshes allowed returning to normal positioning, although at the cost of higher force exerted by the mesh with higher stiffness (3.4 N against 2.3 N), which can relate to tissue erosion. This finite element analysis allowed mimicking the biomechanical response of the pelvic structures in response to changing a material property of the midurethral synthetic mesh.
Pelvic floor muscle biometry and pelvic organ mobility in East Asian and Caucasian nulliparae.
Cheung, R Y K; Shek, K L; Chan, S S C; Chung, T K H; Dietz, H P
2015-05-01
To compare the differences in levator ani muscle biometry and hiatal dimensions between pregnant nulliparous Caucasian and East Asian women. Offline analysis of three/four-dimensional ultrasound volume data obtained from two groups of pregnant nulliparous women, Caucasian and East Asian, was performed. Volume acquisition was performed in the late third trimester using the same method in both groups, in the context of two prospective observational studies with identical entry criteria. Pelvic organ descent and levator hiatal dimensions were assessed using the volumes acquired on Valsalva maneuver, and pubovisceral muscle thickness was measured from the volumes obtained on pelvic floor muscle contraction (PFMC). Datasets of 200 East Asian and 168 Caucasian women were analyzed. Compared with Caucasian women, East Asian women had a significantly lower body mass index. All indices of pelvic organ descent were significantly higher in the Caucasian group than in the East Asian group. The difference, expressed as a percentage, in levator hiatal area on both Valsalva maneuver and PFMC was markedly greater in Caucasian (32% vs. 19%; P < 0.001) than in East Asian (24% vs. 20%; P = 0.01) women. After controlling for potential confounders using multivariate regression analysis, racial origin remained the only significant factor associated with differences in pelvic organ descent and hiatal dimensions. The thickness and area of pubovisceral muscle were significantly higher in the East Asian group. Pregnant women of East Asian racial origin have a thicker pubovisceral muscle, smaller hiatus and less mobility of pelvic organs than do pregnant Caucasian women. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Knee arthrodesis with an intramedullary nail: a retrospective study.
De Vil, Jeroen; Almqvist, Karl Fredrik; Vanheeren, Philippe; Boone, Barbara; Verdonk, René
2008-07-01
A group of 19 patients who underwent knee arthrodesis with use of an intramedullary nail between 1996 and 2005, was studied. In the majority of patients knee arthrodesis was performed as a salvage procedure for the limb following an infected total knee arthroplasty. The outcome of the procedure was evaluated with radiographs, the SF-36 score and the Oxford 12-item knee score. The functional result of a successful arthrodesis was found to be comparable with that of a revised hinged total knee arthroplasty. Knee arthrodesis with an intramedullary nail allows weightbearing within 1 week and is accompanied by a high rate of pain relief. However, recurrence of infection is the most challenging problem.
NASA Astrophysics Data System (ADS)
Axen, Gary J.; Bartley, John M.; Selverstone, Jane
1995-12-01
The kinematic and temporal sequence of structures observed to overprint mylonites along the Brenner Line low-angle normal fault may record passage of the footwall through two rolling hinges, at the top and bottom of a ramp in the shear zone. The structures comprise west down brittle and brittle-ductile structures and east down brittle structures. PT conditions of formation (250° to >400°C and 2-23 km depth), obtained from analysis of oriented fluid inclusion planes, indicate that west down structures were formed at greater depths and temperatures, and therefore earlier, than the east down structures. These data suggest that the brittle structures formed under conditions that permit crystal-plastic deformation at long-term geologic strain rates and therefore probably reflect transient rapid strain rates and/or high fluid pressure. Structures inferred to have formed at a lower hinge are consistent with viscous flow models of rolling-hinge deformation and support the concept of a crustal asthenosphere. Such high temperatures at shallow crustal depth also suggest significant upward advection of heat by extensional unroofing of warm rocks, which may have reduced the flexural rigidity of the footwall and thus affected mechanical behavior at the upper rolling hinge. Exposed mylonitic foliation within a few hundred meters of the Brenner line and on top of the east-west trending anticlines in the footwall dips ˜15° west. Our data favor a ramp dip of ˜25° but permit a dip as great as 45°. Fluid inclusion data suggest that structures related to the hinge at the base of the ramp formed at depths of 12-25 km. If the average dip of the Brenner shear zone to those depths was 20°, intermediate between the favored ramp dip and the dip of exposed foliation, then the horizontal component of slip could be as high as 33-63 km. The two discrete sets of structures with opposite shear senses, formed in the temporal sequence indicated by PT data, are consistent with subvertical simple shear models of rolling-hinge strain. This kinematic pattern is not predicted by the flexural-failure model for rolling hinges. However, the predominance of normal slip at the upper hinge, which extends rather than shortens the mylonitic foliation, fails to match the subvertical simple shear model, which predicts shortening of the foliation there. One possible solution is that superposition of regional extension upon hinge-related stresses modified the rolling-hinge kinematics. Such a modified subvertical shear model can account for the observed small foliation-parallel extensional strains if the foliation was bent <5°-10° passing through the upper hinge. If more bending than that occurred, the data suggest rolling-hinge kinematics in which deformation is achieved by uniform-sense simple shear across the shear zone as in the subvertical simple shear model but in which material lines parallel to the shear-zone foliation and the detachment fault undergo very small length changes, presumably indicating that footwall rocks retained significant resistance to shear and underwent minimal permanent strain. The mechanics that would generate such a rolling hinge are uncertain but may incorporate aspects of both subvertical simple shear and flexural failure. An important kinematic consequence of such a rolling hinge is that all of the net slip across a normal fault, not only its horizontal component, is converted into horizontal extension. This implies a significantly larger magnitude of crustal extension across dipping normal faults whose footwalls passed through a rolling hinge than for those that did not develop along with a hinge.
Designing Great Hinge Questions
ERIC Educational Resources Information Center
Wiliam, Dylan
2015-01-01
According to author Dylan Wiliam, because lessons never go exactly as planned, teachers should build plan B into plan A. This involves designing a lesson with a "hinge" somewhere in the middle and using specific kinds of questions--what he calls hinge questions--to quickly assess students' understanding of a concept before moving on.…
Non-equivalent role of TM2 gating hinges in heteromeric Kir4.1/Kir5.1 potassium channels.
Shang, Lijun; Tucker, Stephen J
2008-02-01
Comparison of the crystal structures of the KcsA and MthK potassium channels suggests that the process of opening a K(+) channel involves pivoted bending of the inner pore-lining helices at a highly conserved glycine residue. This bending motion is proposed to splay the transmembrane domains outwards to widen the gate at the "helix-bundle crossing". However, in the inwardly rectifying (Kir) potassium channel family, the role of this "hinge" residue in the second transmembrane domain (TM2) and that of another putative glycine gating hinge at the base of TM2 remain controversial. We investigated the role of these two positions in heteromeric Kir4.1/Kir5.1 channels, which are unique amongst Kir channels in that both subunits lack a conserved glycine at the upper hinge position. Contrary to the effect seen in other channels, increasing the potential flexibility of TM2 by glycine substitutions at the upper hinge position decreases channel opening. Furthermore, the contribution of the Kir4.1 subunit to this process is dominant compared to Kir5.1, demonstrating a non-equivalent contribution of these two subunits to the gating process. A homology model of heteromeric Kir4.1/Kir5.1 shows that these upper "hinge" residues are in close contact with the base of the pore alpha-helix that supports the selectivity filter. Our results also indicate that the highly conserved glycine at the "lower" gating hinge position is required for tight packing of the TM2 helices at the helix-bundle crossing, rather than acting as a hinge residue.
NASA Technical Reports Server (NTRS)
Rignot, Eric
1997-01-01
Satellite synthetic-aperture radar (SAR) Interferometry is employed to map the hinge line, or limit of tidal flexing, of Rutford Ice Stream and Carlson Inlet, Antarctica, and detect its migration between 1992 and 1996. The hinge line is mapped using a model fit from an elastic beam theory.
77 FR 49396 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-16
... option for installing a redesigned aft hinge fitting with the trim already done, instead of trimming an... installing a redesigned aft hinge fitting with the trim already done, instead of trimming an existing or new... action in the existing AD) for installing a redesigned aft hinge fitting designed with the trim already...
78 FR 33197 - Airworthiness Directives; Iniziative Industriali Italiane S.p.A. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
... plane hinge assembly. We are issuing this AD to require actions to address the unsafe condition on these... plane hinge assembly have been reported. This condition, if not detected and corrected, could lead to... bearing and the horizontal tail/elevator plane hinge assembly to detect any crack, signs of corrosion or...
Dalvand, Hamid; Dehghan, Leila; Feizi, Awat; Hosseini, Seyed Ali; Amirsalari, Susan
2013-01-01
The purpose of this study was to examine the impacts of hinged and solid anklefoot orthoses (AFOs) on standing and walking abilities in children with spastic diplegia. In a quasi-experimental design, 30 children with spastic diplegia, aged 4-6 years were recruited. They were matched in terms of age, IQ, and level of GMFCS E&R. Children were randomly assigned into 3 groups: a hinged AFO group (n=10) plus occupational therapy (OT), a solid AFO group (n=10) plus OT, a control group who used only OT for three months. Gross motor abilities were measured using Gross Motor Measure Function (GMFM). We obtained statistically significant differences in the values between baseline and after treatment in all groups. The groups were also significantly different in total GMFM after intervention. Furthermore, there were differences between hinged AFOs and solid AFOs groups, and between hinged AFOs and control groups. We concluded that gross motor function was improved in all groups; however, hinged AFOs group appears to improve the gross motor function better than solid AFOs and control groups.
NASA Technical Reports Server (NTRS)
Fleischer, G. E.; Likins, P. W.
1975-01-01
Three computer subroutines designed to solve the vector-dyadic differential equations of rotational motion for systems that may be idealized as a collection of hinge-connected rigid bodies assembled in a tree topology, with an optional flexible appendage attached to each body are reported. Deformations of the appendages are mathematically represented by modal coordinates and are assumed small. Within these constraints, the subroutines provide equation solutions for (1) the most general case of unrestricted hinge rotations, with appendage base bodies nominally rotating at a constant speed, (2) the case of unrestricted hinge rotations between rigid bodies, with the restriction that those rigid bodies carrying appendages are nominally nonspinning, and (3) the case of small hinge rotations and nominally nonrotating appendages. Sample problems and their solutions are presented to illustrate the utility of the computer programs.
Design and 4D Printing of Cross-Folded Origami Structures: A Preliminary Investigation.
Teoh, Joanne Ee Mei; An, Jia; Feng, Xiaofan; Zhao, Yue; Chua, Chee Kai; Liu, Yong
2018-03-03
In 4D printing research, different types of complex structure folding and unfolding have been investigated. However, research on cross-folding of origami structures (defined as a folding structure with at least two overlapping folds) has not been reported. This research focuses on the investigation of cross-folding structures using multi-material components along different axes and different horizontal hinge thickness with single homogeneous material. Tensile tests were conducted to determine the impact of multi-material components and horizontal hinge thickness. In the case of multi-material structures, the hybrid material composition has a significant impact on the overall maximum strain and Young's modulus properties. In the case of single material structures, the shape recovery speed is inversely proportional to the horizontal hinge thickness, while the flexural or bending strength is proportional to the horizontal hinge thickness. A hinge with a thickness of 0.5 mm could be folded three times prior to fracture whilst a hinge with a thickness of 0.3 mm could be folded only once prior to fracture. A hinge with a thickness of 0.1 mm could not even be folded without cracking. The introduction of a physical hole in the center of the folding/unfolding line provided stress relief and prevented fracture. A complex flower petal shape was used to successfully demonstrate the implementation of overlapping and non-overlapping folding lines using both single material segments and multi-material segments. Design guidelines for establishing cross-folding structures using multi-material components along different axes and different horizontal hinge thicknesses with single or homogeneous material were established. These guidelines can be used to design and implement complex origami structures with overlapping and non-overlapping folding lines. Combined overlapping folding structures could be implemented and allocating specific hole locations in the overall designs could be further explored. In addition, creating a more precise prediction by investigating sets of in between hinge thicknesses and comparing the folding times before fracture, will be the subject of future work.
Custom rotating hinge total knee arthroplasty in patients with poliomyelitis affected limbs.
Rahman, Jeeshan; Hanna, Sammy A; Kayani, Babar; Miles, Jonathan; Pollock, Robin C; Skinner, John A; Briggs, Timothy W; Carrington, Richard W
2015-05-01
Total knee arthroplasty (TKA) in limbs affected by poliomyelitis is a technically challenging procedure. These patients often demonstrate acquired articular and metaphyseal angular deformities, bone loss, narrowness of the intramedullary canals, impaired quadriceps strength, flexion contractures and ligamentous laxity producing painful hyperextension. Thus, using condylar knee designs in these patients will likely result in early failure because of instability and abnormal load distribution. The aim of this study was to assess the outcomes associated with use of the customised (SMILES) rotating-hinge knee system at our institution for TKA in poliomyelitis-affected limbs. We retrospectively reviewed the outcome of 14 TKAs using the (SMILES) prosthesis in 13 patients with limbs affected by poliomyelitis. All patients had painful unstable knees with hyperextension. There were ten females and three males with a mean age of 66 years (range 51-84) at time of surgery. Patients were followed up clinically, radiologically and functionally with the Oxford knee score (OKS). Mean follow-up was 72 months (16-156). There were no immediate or early complications. One patient fell and sustained a peri-prosthetic fracture at seven months requiring revision to a longer stem. Radiological evaluation showed satisfactory alignment with no signs of loosening in all cases. Mean OKS improved from 11.6 (4-18) to 31.5 (18-40) postoperatively (p < 0.001). The rotating hinge (SMILES) prosthesis is effective at relieving pain and improving function in patients with poliomyelitis. The device compensates well for ligamentous insufficiency as well as for any associated bony deformity.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-10
..., an operator found an aileron trim tab hinge pin that had migrated sufficiently to cause a rubbing.... Recently, during a walk round check, an operator found an aileron trim tab hinge pin that had migrated... walk round check, an operator found an aileron trim tab hinge pin that had migrated sufficiently to...
Window Operator Types | Efficient Windows Collaborative
Types Casement Casement Casement windows are hinged at the sides. Hinged windows such as casements operating types to consider. Traditional operable window types include the projected or hinged types such as casement, awning, and hopper, and the sliding types such as double- and single-hung and horizontal sliding
Bilateral custom-fit total knee arthroplasty in a patient with poliomyelitis.
Tardy, Nicolas; Chambat, Pierre; Murphy, Colin G; Fayard, Jean-Marie
2014-09-01
In limbs affected by poliomyelitis, total knee arthroplasty results in satisfactory pain relief. However, the risk of failure is high, especially if the preoperative quadriceps power is low. Therefore, treating osteoarthritis in the current patient represented a challenging procedure. A 66-year-old man presented with tricompartmental osteoarthritis of both knees, with valgus deformity of 14° on the left knee and 11° on the right knee. He walked with a bilateral knee recurvatum of 30° and a grade 1 quadriceps power. The authors treated both knees with cemented custom-fit hinged total knee arthroplasty with 30° of recurvatum in the tibial keel. Clinical scores showed good results 1 year postoperatively, especially on the subjective data of quality of life and function. At follow-up, radiographs showed good total knee arthroplasty positioning on the right side and a small mechanical loosening at the end of the tibial keel on the left side. Only 5 studies (Patterson and Insall; Moran; Giori and Lewallen; Jordan et al; and Tigani et al) have reported total knee arthroplasty results in patients with poliomyelitis. This study reports an original case of bilateral custom-fit hinged total knee arthroplasty in a patient with poliomyelitis. To the authors' knowledge, this is the first report of this type of procedure in the literature. The key point is the degree of recurvatum that is needed to allow walking, avoiding excessive constraints on the implants that can lead to early mechanical failure. Copyright 2014, SLACK Incorporated.
Matsuo, Kiyoshi; Osada, Yoshiro; Ban, Ryokuya
2013-02-01
The levator and frontalis muscles lack interior muscle spindles, despite consisting of slow-twitch fibres that involuntarily sustain eyelid-opening and eyebrow-raising against gravity. To compensate for this anatomical defect, this study hypothetically proposes that initial voluntary contraction of the levator fast-twitch muscle fibres stretches the mechanoreceptors in Müller's muscle and evokes proprioception, which continuously induces reflex contraction of slow-twitch fibres of the levator and frontalis muscles. This study sought to determine whether unilateral transcutaneous electrical stimulation to the trigeminal proprioceptive fibres that innervate the mechanoreceptors in Müller's muscle could induce electromyographic responses in the frontalis muscles, with monitoring responses in the orbicularis oculi muscles. The study population included 27 normal subjects and 23 subjects with aponeurotic blepharoptosis, who displayed persistently raised eyebrows on primary gaze and light eyelid closure. The stimulation induced a short-latency response in the ipsilateral frontalis muscle of all subjects and long-latency responses in the bilateral frontalis muscles of normal subjects. However, it did not induce long-latency responses in the bilateral frontalis muscles of subjects with aponeurotic blepharoptosis. The orbicularis oculi muscles showed R1 and/or R2 responses. The stimulation might reach not only the proprioceptive fibres, but also other sensory fibres related to the blink or corneal reflex. The experimental system can provoke a monosynaptic short-latency response in the ipsilateral frontalis muscle, probably through the mesencephalic trigeminal proprioceptive neuron and the frontalis motor neuron, and polysynaptic long-latency responses in the bilateral frontalis muscles through an unknown pathway. The latter neural circuit appeared to be engaged by the circumstances of aponeurotic blepharoptosis.
Kolberg Tennfjord, M; Hilde, G; Staer-Jensen, J; Siafarikas, F; Engh, M Ellström; Bø, K
2016-03-01
Evaluate effect of pelvic floor muscle training (PFMT) on vaginal symptoms and sexual matters, dyspareunia and coital incontinence in primiparous women stratified by major or no defects of the levator ani muscle. Randomised controlled trial (RCT). Akershus University Hospital, Norway. About 175 primiparous women with a singleton vaginal delivery. Two-armed assessor blinded parallel group RCT from 6 weeks to 6 months postpartum comparing effect of PFMT versus control. International Consultation on Incontinence Modular Questionnaire-vaginal symptoms questionnaire (ICIQ-VS) and ICIQ sexual matters module (ICIQ-FLUTSsex). Overall, analysis (n = 175) showed no difference between training and control groups in women having vaginal symptoms or symptoms related to sexual dysfunction 6 months postpartum. The majority of women (88%) had intercourse and there was no difference between groups. Unadjusted subgroup analysis of women with a major defect of the levator ani muscle (n = 55) showed that women in the training group had 45% less risk of having the symptom 'vagina feels loose or lax' compared with the control group (relative risk 0.55, 95% confidence interval 0.31, 0.95; P = 0.03). Unadjusted analysis showed that in women with major defect of the levator ani muscle, significantly fewer in the training group had the symptom 'vagina feels loose or lax' compared with the control group. No difference was found between groups for symptoms related to sexual dysfunction. More studies are needed to explore effect of PFMT on vaginal symptoms and sexual dysfunction. Unadjusted analysis shows that PFMT might prevent symptoms of 'vagina feels loose or lax'. © 2015 Royal College of Obstetricians and Gynaecologists.
Araujo Júnior, Edward; de Freitas, Rogério Caixeta Moraes; Di Bella, Zsuzsanna Ilona Katalin de Jármy; Alexandre, Sandra Maria; Nakamura, Mary Uchiyama; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes
2013-03-01
To evaluate changes to the pelvic floor of primiparous women with different delivery modes, using three-dimensional ultrasound. A prospective cross-sectional study on 35 primiparae divided into groups according to the delivery mode: elective cesarean delivery (n=10), vaginal delivery (n=16), and forceps delivery (n=9). Three-dimensional ultrasound on the pelvic floor was performed on the second postpartum day with the patient in a resting position. A convex volumetric transducer (RAB4-8L) was used, in contact with the large labia, with the patient in the gynecological position. Biometric measurements of the urogenital hiatus were taken in the axial plane on images in the rendering mode, in order to assess the area, anteroposterior and transverse diameters, average thickness, and avulsion of the levator ani muscle. Differences between groups were evaluated by determining the mean differences and their respective 95% confidence intervals. The proportions of levator ani muscle avulsion were compared between elective cesarean section and vaginal birth using Fisher's exact test. The mean areas of the urogenital hiatus in the cases of vaginal and forceps deliveries were 17.0 and 20.1 cm(2), respectively, versus 12.4 cm(2) in the Control Group (elective cesarean). Avulsion of the levator ani muscle was observed in women who underwent vaginal delivery (3/25), however there was no statistically significant difference between cesarean section and vaginal delivery groups (p=0.5). Transperineal three-dimensional ultrasound was useful for assessing the pelvic floor of primiparous women, by allowing pelvic morphological changes to be differentiated according to the delivery mode.
2011-01-01
Background Many adults experience bothersome neck/shoulder pain. While research and treatment strategies often focus on the upper trapezius, other neck/shoulder muscles may be affected as well. The aim of the present study is to evaluate the prevalence and anatomical location of muscle tenderness in adults with nonspecific neck/shoulder pain. Methods Clinical neck/shoulder examination at two large office workplaces in Copenhagen, Denmark. 174 women and 24 men (aged 25-65 years) with nonspecific neck/shoulder pain for a duration of at least 30 days during the previous year and a pain intensity of at least 2 on a modified VAS-scale of 0-10 participated. Exclusion criteria were traumatic injuries or other serious chronic disease. Using a standardized finger pressure of 2 kg, palpable tenderness were performed of eight anatomical neck/shoulder locations in the left and right side on a scale of 'no tenderness', 'some tenderness' and 'severe tenderness'. Results In women, the levator scapulae, neck extensors and infraspinatus showed the highest prevalence of severe tenderness (18-30%). In comparison, the prevalence of severe tenderness in the upper trapezius, occipital border and supraspinatus was 13-19%. Severe tenderness of the medial deltoid was least prevalent (0-1%). In men, the prevalence of severe tenderness in the levator scapulae was 13-21%, and ranged between 0-8% in the remainder of the examined anatomical locations. Conclusions A high prevalence of tenderness exists in several anatomical locations of the neck/shoulder complex among adults with nonspecific neck/shoulder pain. Future research should focus on several neck/shoulder muscles, including the levator scapulae, neck extensors and infraspinatus, and not only the upper trapezius. Trial Registration ISRCTN60264809 PMID:21777478
Botulinum neurotoxin type A injections for vaginismus secondary to vulvar vestibulitis syndrome.
Bertolasi, Laura; Frasson, Emma; Cappelletti, Jee Yun; Vicentini, Silvana; Bordignon, Monia; Graziottin, Alessandra
2009-11-01
To investigate whether botulinum neurotoxin type A improves vaginismus and study its efficacy with repeated treatments. Outpatients were referred because standard cognitive-behavioral and medical treatment for vaginismus and vulvar vestibular syndrome failed. From this group, we prospectively recruited consecutive women (n=39) whose diagnostic electromyogram (EMG) recordings from the levator ani muscle showed hyperactivity at rest and reduced inhibition during straining. These women were followed for a mean (+/-standard deviation) of 105 (+/-50) weeks. Recruited patients underwent repeated cycles of botulinum neurotoxin type A injected into the levator ani under EMG guidance and EMG monitoring thereafter. At enrollment and 4 weeks after each cycle, women were asked about sexual intercourse; underwent EMG evaluation and examinations to grade vaginal resistance according to Lamont; and completed a visual analog scale (VAS) for pain, the Female Sexual Function Index Scale, a quality-of-life questionnaire (Short-Form 12 Health Survey), and bowel and bladder symptom assessment. At 4 weeks after the first botulinum neurotoxin type A cycle, the primary outcome measures (the possibility of having sexual intercourse, and levator ani EMG hyperactivity) both improved, as did the secondary outcomes, Lamont scores, VAS, Female Sexual Function Index Scales, Short-Form 12 Health Survey, and bowel-bladder symptoms. These benefits persisted through later cycles. When follow-up ended, 63.2% of the patients completely recovered from vaginismus and vulvar vestibular syndrome, 15.4% still needed reinjections (censored), and 15.4% had dropped out. Botulinum neurotoxin type A is an effective treatment option for vaginismus secondary to vulvar vestibular syndrome refractory to standard cognitive-behavioral and medical management. After patients received botulinum neurotoxin type A, their sexual activity improved and reinjections provided sustained benefits. III.
Andersen, Lars L; Hansen, Klaus; Mortensen, Ole S; Zebis, Mette K
2011-07-22
Many adults experience bothersome neck/shoulder pain. While research and treatment strategies often focus on the upper trapezius, other neck/shoulder muscles may be affected as well. The aim of the present study is to evaluate the prevalence and anatomical location of muscle tenderness in adults with nonspecific neck/shoulder pain. Clinical neck/shoulder examination at two large office workplaces in Copenhagen, Denmark. 174 women and 24 men (aged 25-65 years) with nonspecific neck/shoulder pain for a duration of at least 30 days during the previous year and a pain intensity of at least 2 on a modified VAS-scale of 0-10 participated. Exclusion criteria were traumatic injuries or other serious chronic disease. Using a standardized finger pressure of 2 kg, palpable tenderness were performed of eight anatomical neck/shoulder locations in the left and right side on a scale of 'no tenderness', 'some tenderness' and 'severe tenderness'. In women, the levator scapulae, neck extensors and infraspinatus showed the highest prevalence of severe tenderness (18-30%). In comparison, the prevalence of severe tenderness in the upper trapezius, occipital border and supraspinatus was 13-19%. Severe tenderness of the medial deltoid was least prevalent (0-1%). In men, the prevalence of severe tenderness in the levator scapulae was 13-21%, and ranged between 0-8% in the remainder of the examined anatomical locations. A high prevalence of tenderness exists in several anatomical locations of the neck/shoulder complex among adults with nonspecific neck/shoulder pain. Future research should focus on several neck/shoulder muscles, including the levator scapulae, neck extensors and infraspinatus, and not only the upper trapezius. ISRCTN60264809.
Borowska-Wykret, Dorota; Rypien, Aleksandra; Dulski, Mateusz; Grelowski, Michal; Wrzalik, Roman; Kwiatkowska, Dorota
2017-06-01
The capitulum of Helichrysum bracteatum is surrounded by scarious involucral bracts that perform hygroscopic movements leading to bract bending toward or away from the capitulum, depending on cell wall water status. The present investigation aimed at explaining the mechanism of these movements. Surface strain and bract shape changes accompanying the movements were quantified using the replica method. Dissection experiments were used to assess the contribution of different tissues in bract deformation. Cell wall structure and composition were examined with the aid of light and electron microscopy as well as confocal Raman spectroscopy. At the bract hinge (organ actuator) longitudinal strains at opposite surfaces differ profoundly. This results in changes of hinge curvature that drive passive displacement of distal bract portions. The distal portions in turn undergo nearly uniform strain on both surfaces and also minute shape changes. The hinge is built of sclerenchyma-like abaxial tissue, parenchyma and adaxial epidermis with thickened outer walls. Cell wall composition is rather uniform but tissue fraction occupied by cell walls, cell wall thickness, compactness and cellulose microfibril orientation change gradually from abaxial to adaxial hinge surface. Dissection experiments show that the presence of part of the hinge tissues is enough for movements. Differential strain at the hinge is due to adaxial-abaxial gradient in structural traits of hinge tissues and cell walls. Thus, the bract hinge of H. bracteatum is a structure comprising gradually changing tissues, from highly resisting to highly active, rather than a bi-layered structure with distinct active and resistance parts, often ascribed for hygroscopically moving organs. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Lee, Wei-Shiun; Linz, Shang-Chih; Shih, Kao-Shang; Chao, Ching-Kong; Chen, Yeung-Jen; Fan, Chang-Yuan
2012-10-01
Stiffness and contracture of the periarticular tissues are common complications of a post-traumatic elbow. Arthrodiatasis is a surgical technique that uses an external fixator for initial immobilization and subsequent distraction. The two prerequisites for an ideal arthrodiatasis are concentric distraction (avoiding bony contact) and hinge alignment (reducing internal stress). This study used the finite element (FE) method to clarify the relationship between these two prerequisites and the initial conditions (pin placement, elbow angle, and distraction mode). A total of 12 variations of the initial conditions were symmetrically arranged to evaluate their biomechanical influence on concentric distraction and hinge alignment. The humeroulnar surface was hypothesized to be ideally distracted orthogonal to the line joining the tips of the olecranon and the coronoid. The eccentric separation of the humeroulnar surfaces is a response to the non-orthogonality of the distracting force and joining line. Pin placement significantly affects the effective moment arm of the fixing pins to distract the bridged elbow. Both elbow angle and distraction mode directly alter the direction of the distracting force at the elbow center. In general, the hinges misalignment occurs in a direction opposite to the distraction-activated site. After joint distraction, the elastic deflection of the fixing pins inevitably makes both elbow and fixator hinges to misalign. This indicates that both joint distraction and hinge alignment are the interactive mechanisms. The humeroulnar separation is more concentric in the situation of the 120 degrees humeral distraction by using stiffer pins with convergent placement. Even so, the eccentric displacement of the elbow hinge is a crucial consideration in the initial placement of the guiding pin to compensate for hinge misalignment.
Hespen, Charles W; Bruegger, Joel J; Guo, Yirui; Marletta, Michael A
2018-06-15
Heme nitric oxide/oxygen sensing (H-NOX) domains are direct NO sensors that regulate a variety of biological functions in both bacteria and eukaryotes. Previous work on H-NOX proteins has shown that upon NO binding, a conformational change occurs along two glycine residues on adjacent helices (termed the glycine hinge). Despite the apparent importance of the glycine hinge, it is not fully conserved in all H-NOX domains. Several H-NOX sensors from the family Flavobacteriaceae contain a native alanine substitution in one of the hinge residues. In this work, the effect of the increased steric bulk within the Ala-Gly hinge on H-NOX function was investigated. The hinge in Kordia algicida OT-1 ( Ka H-NOX) is composed of A71 and G145. Ligand-binding properties and signaling function for this H-NOX were characterized. The variant A71G was designed to convert the hinge region of Ka H-NOX to the typical Gly-Gly motif. In activity assays with its cognate histidine kinase (HnoK), the wild type displayed increased signal specificity compared to A71G. Increasing titrations of unliganded A71G gradually inhibits HnoK autophosphorylation, while increasing titrations of unliganded wild type H-NOX does not inhibit HnoK. Crystal structures of both wild type and A71G Ka H-NOX were solved to 1.9 and 1.6 Å, respectively. Regions of H-NOX domains previously identified as involved in protein-protein interactions with HnoK display significantly higher b-factors in A71G compared to wild-type H-NOX. Both biochemical and structural data indicate that the hinge region controls overall conformational flexibility of the H-NOX, affecting NO complex formation and regulation of its HnoK.
The role of hinges in primary total knee replacement.
Gehrke, T; Kendoff, D; Haasper, C
2014-11-01
The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.
Analysis of intelligent hinged shell structures: deployable deformation and shape memory effect
NASA Astrophysics Data System (ADS)
Shi, Guang-Hui; Yang, Qing-Sheng; He, X. Q.
2013-12-01
Shape memory polymers (SMPs) are a class of intelligent materials with the ability to recover their initial shape from a temporarily fixable state when subjected to external stimuli. In this work, the thermo-mechanical behavior of a deployable SMP-based hinged structure is modeled by the finite element method using a 3D constitutive model with shape memory effect. The influences of hinge structure parameters on the nonlinear loading process are investigated. The total shape memory of the processes the hinged structure goes through, including loading at high temperature, decreasing temperature with load carrying, unloading at low temperature and recovering the initial shape with increasing temperature, are illustrated. Numerical results show that the present constitutive theory and the finite element method can effectively predict the complicated thermo-mechanical deformation behavior and shape memory effect of SMP-based hinged shell structures.
Ontogeny of the cranial musculature in Corydoras aeneus Callichthyidae, Siluriformes.
Huysentruyt, F; Brunain, M; Adriaens, D
2009-11-01
A complete study of the early ontogeny of the cranial muscles of Corydoras aeneus (Callichthyidae) was undertaken and results were compared with those for the loricariid Ancistrus cf. triradiatus. This comparison reveals a high degree of similarity in the ontogeny of both species' cranial muscles. Both species lack a musculus protractor hyoidei, and the musculus intermandibularis posterior is divided into two different parts that have partly obtained a novel function (serving the lower lip) in A. cf. triradiatus. A similar increase in muscular complexity in this species is found in the dorsal constrictor of the hyoid muscle plate. This constrictor gives rise to the same muscles in both C. aeneus and A. cf. triradiatus, but in A. cf. triradiatus the musculus levator operculi later hypertrophies. In C. aeneus the musculus extensor tentaculi forms a single muscle diverging posteriorly, whereas in A. cf. triradiatus the musculus extensor tentaculi differentiates into two separate bundles. Also, a loricariid neoformation is present called the musculus levator tentaculi.
Whitton, Alexis E; Henry, Julie D; Rendell, Peter G; Grisham, Jessica R
2014-02-01
Physical disgust is elicited by, and amplifies responses to, moral transgressions, suggesting that moral disgust may be a biologically expanded form of physical disgust. However, there is limited research comparing the effects of physical disgust to that of other emotions like anger, making it difficult to determine if the link between disgust and morality is unique. The current research evaluated the specificity of the relationship between disgust and morality by comparing links with anger, using state, physiological and trait measures of emotionality. Participants (N=90) were randomly allocated to have disgust, anger or no emotion induced. Responses to images depicting moral, negative non-moral, and neutral themes were then recorded using facial electromyography. Inducing disgust, but not anger, increased psychophysiological responses to moral themes. Trait disgust, but not trait anger, correlated with levator labii responses to moral themes. These findings provide strong evidence of a unique link between physical disgust and morality. Copyright © 2013 Elsevier B.V. All rights reserved.
Levator claviculae muscle discovered during physical examination for cervical lymphadenopathy.
Rosenheimer, J L; Loewy, J; Lozanoff, S
2000-01-01
During a routine physical examination of an adult female with a history of breast cancer and cervical lymphadenopathy, a mass was noted in the right supraclavicular region. The mass was unilateral and easily palpable along the superior border near the median aspect of the clavicle. Plain film radiography, performed to determine whether the mass represented an enlarged jugulo-omohyoid lymph node, revealed an elongated opaque mass in this region. Computed tomographic (CT) and magnetic resonance (MR) images were subsequently obtained. Sequential axial CT scans revealed a cylindrical mass that appeared to be independent of contiguous muscles, including the sternocleidomastoid, anterior, and middle scalene muscles. This mass attached inferiorly to the clavicle and superiorly to the transverse process of the sixth cervical vertebra. Sagittal, coronal, and axial MR scans confirmed the presence of a well-defined superficial mass. It is concluded that the mass represents a levator claviculae (cleidocervical) muscle. This observation underscores the importance of understanding soft tissue variants that may be encountered during a routine physical examination. Copyright 2000 Wiley-Liss, Inc.
Pelvic and perineal anatomy of the male gorilla: selected observations.
Oelrich, T M
1978-08-01
The anatomy of parts of the pelvic outlet and perineum is described in an adult male gorilla. Two previously undescribed muscles are presented: (1) The puborectalis muscle, completely separated from the levator ani, arises from the region of the symphysis and forms a sling for the rectum while it also substitutes for the perineal membrane. (2) The puboampullaris muscle, a paired smooth muscle, arises from the pubis and inserts into the rectum to elevate the rectum while additionally providing support for the urogenital viscera. The levator ani muscle is recounted to point out its lack of attachment to the pelvic viscera while allowing a hiatus in which the rectum is exposed within the perineum. The sphincter urethrae muscle is presented emphasizing its true sphincteric characteristics, its absence of lateral attachments and its similarity to man. Other muscles of the pelvis and perineum as well as urogenital viscera are described or modified where necessary. The manner in which these structures enter into the support of the pelvic viscera is considered.
NASA Technical Reports Server (NTRS)
Schoen, A. H. (Inventor)
1973-01-01
Expandable space frames having essentially infinite periodicity limited only by practical considerations, are described. Each expandable space frame comprises a plurality of hinge joint assemblies having arms that extend outwardly in predetermined symmetrically related directions from a central or vertex point. The outer ends of the arms form one part of a hinge point. The outer expandable space frame also comprises a plurality of struts. The outer ends of the struts from the other part of the hinged joint. The struts interconnect the plurality of hinge point in sychronism, the spaceframes can be expanded or collapsed. Three-dimensional as well as two-dimensional spaceframes of this general nature are described.
Graphite Composite Booms with Integral Hinges
NASA Technical Reports Server (NTRS)
Alexander, Wes; Carlos, Rene; Rossoni, Peter; Sturm, James
2006-01-01
A document discusses lightweight instrument booms under development for use aboard spacecraft. A boom of this type comprises a thin-walled graphite fiber/ matrix composite tube with an integral hinge that can be bent for stowage and later allowed to spring back to straighten the boom for deployment in outer space. The boom design takes advantage of both the stiffness of the composite in tubular geometry and the flexibility of thin sections of the composite. The hinge is formed by machining windows in the tube at diametrically opposite locations so that there remain two opposing cylindrical strips resembling measuring tapes. Essential to the design is a proprietary composite layup that renders the hinge tough yet flexible enough to be bendable as much as 90 in either of two opposite directions. When the boom is released for deployment, the torque exerted by the bent hinge suffices to overcome parasitic resistance from harnesses and other equipment, so that the two sections of the hinge snap to a straight, rigid condition in the same manner as that of measuring tapes. Issues addressed in development thus far include selection of materials, out-of-plane bending, edge cracking, and separation of plies.
Bolger, Conor M.; Sandbakk, Øyvind; Ettema, Gertjan; Federolf, Peter
2016-01-01
The purposes of the current study were to 1) test if the hinge position in the binding of skating skis has an effect on gross efficiency or cycle characteristics and 2) investigate whether hinge positioning affects synergistic components of the muscle activation in six lower leg muscles. Eleven male skiers performed three 4-min sessions at moderate intensity while cross-country ski-skating and using a klapskate binding. Three different positions were tested for the binding’s hinge, ranging from the front of the first distal phalange to the metatarsal-phalangeal joint. Gross efficiency and cycle characteristics were determined, and the electromyographic (EMG) signals of six lower limb muscles were collected. EMG signals were wavelet transformed, normalized, joined into a multi-dimensional vector, and submitted to a principle component analysis (PCA). Our results did not reveal any changes to gross efficiency or cycle characteristics when altering the hinge position. However, our EMG analysis found small but significant effects of hinge positioning on muscle coordinative patterns (P < 0.05). The changed patterns in muscle activation are in alignment with previously described mechanisms that explain the effects of hinge positioning in speed-skating klapskates. Finally, the within-subject results of the EMG analysis suggested that in addition to the between-subject effects, further forms of muscle coordination patterns appear to be employed by some, but not all participants. PMID:27203597
Engineering Upper Hinge Improves Stability and Effector Function of a Human IgG1
Yan, Boxu; Boyd, Daniel; Kaschak, Timothy; Tsukuda, Joni; Shen, Amy; Lin, Yuwen; Chung, Shan; Gupta, Priyanka; Kamath, Amrita; Wong, Anne; Vernes, Jean-Michel; Meng, Gloria Y.; Totpal, Klara; Schaefer, Gabriele; Jiang, Guoying; Nogal, Bartek; Emery, Craig; Vanderlaan, Martin; Carter, Paul; Harris, Reed; Amanullah, Ashraf
2012-01-01
Upper hinge is vulnerable to radical attacks that result in breakage of the heavy-light chain linkage and cleavage of the hinge of an IgG1. To further explore mechanisms responsible for the radical induced hinge degradation, nine mutants were designed to determine the roles that the upper hinge Asp and His play in the radical reactions. The observation that none of these substitutions could inhibit the breakage of the heavy-light chain linkage suggests that the breakage may result from electron transfer from Cys231 directly to the heavy-light chain linkage upon radical attacks, and implies a pathway separate from His229-mediated hinge cleavage. On the other hand, the substitution of His229 with Tyr showed promising advantages over the native antibody and other substitutions in improving the stability and function of the IgG1. This substitution inhibited the hinge cleavage by 98% and suggests that the redox active nature of Tyr did not enable it to replicate the ability of His to facilitate radical induced degradation. We propose that the lower redox potential of Tyr, a residue that may be the ultimate sink for oxidizing equivalents in proteins, is responsible for the inhibition. More importantly, the substitution increased the antibody's binding to FcγRIII receptors by 2–3-fold, and improved ADCC activity by 2-fold, while maintaining a similar pharmacokinetic profile with respect to the wild type. Implications of these observations for antibody engineering and development are discussed. PMID:22203673
Engineering upper hinge improves stability and effector function of a human IgG1.
Yan, Boxu; Boyd, Daniel; Kaschak, Timothy; Tsukuda, Joni; Shen, Amy; Lin, Yuwen; Chung, Shan; Gupta, Priyanka; Kamath, Amrita; Wong, Anne; Vernes, Jean-Michel; Meng, Gloria Y; Totpal, Klara; Schaefer, Gabriele; Jiang, Guoying; Nogal, Bartek; Emery, Craig; Vanderlaan, Martin; Carter, Paul; Harris, Reed; Amanullah, Ashraf
2012-02-17
Upper hinge is vulnerable to radical attacks that result in breakage of the heavy-light chain linkage and cleavage of the hinge of an IgG1. To further explore mechanisms responsible for the radical induced hinge degradation, nine mutants were designed to determine the roles that the upper hinge Asp and His play in the radical reactions. The observation that none of these substitutions could inhibit the breakage of the heavy-light chain linkage suggests that the breakage may result from electron transfer from Cys(231) directly to the heavy-light chain linkage upon radical attacks, and implies a pathway separate from His(229)-mediated hinge cleavage. On the other hand, the substitution of His(229) with Tyr showed promising advantages over the native antibody and other substitutions in improving the stability and function of the IgG1. This substitution inhibited the hinge cleavage by 98% and suggests that the redox active nature of Tyr did not enable it to replicate the ability of His to facilitate radical induced degradation. We propose that the lower redox potential of Tyr, a residue that may be the ultimate sink for oxidizing equivalents in proteins, is responsible for the inhibition. More importantly, the substitution increased the antibody's binding to FcγRIII receptors by 2-3-fold, and improved ADCC activity by 2-fold, while maintaining a similar pharmacokinetic profile with respect to the wild type. Implications of these observations for antibody engineering and development are discussed.
Design and 4D Printing of Cross-Folded Origami Structures: A Preliminary Investigation
Teoh, Joanne Ee Mei; Feng, Xiaofan; Zhao, Yue; Liu, Yong
2018-01-01
In 4D printing research, different types of complex structure folding and unfolding have been investigated. However, research on cross-folding of origami structures (defined as a folding structure with at least two overlapping folds) has not been reported. This research focuses on the investigation of cross-folding structures using multi-material components along different axes and different horizontal hinge thickness with single homogeneous material. Tensile tests were conducted to determine the impact of multi-material components and horizontal hinge thickness. In the case of multi-material structures, the hybrid material composition has a significant impact on the overall maximum strain and Young’s modulus properties. In the case of single material structures, the shape recovery speed is inversely proportional to the horizontal hinge thickness, while the flexural or bending strength is proportional to the horizontal hinge thickness. A hinge with a thickness of 0.5 mm could be folded three times prior to fracture whilst a hinge with a thickness of 0.3 mm could be folded only once prior to fracture. A hinge with a thickness of 0.1 mm could not even be folded without cracking. The introduction of a physical hole in the center of the folding/unfolding line provided stress relief and prevented fracture. A complex flower petal shape was used to successfully demonstrate the implementation of overlapping and non-overlapping folding lines using both single material segments and multi-material segments. Design guidelines for establishing cross-folding structures using multi-material components along different axes and different horizontal hinge thicknesses with single or homogeneous material were established. These guidelines can be used to design and implement complex origami structures with overlapping and non-overlapping folding lines. Combined overlapping folding structures could be implemented and allocating specific hole locations in the overall designs could be further explored. In addition, creating a more precise prediction by investigating sets of in between hinge thicknesses and comparing the folding times before fracture, will be the subject of future work. PMID:29510503
NASA Technical Reports Server (NTRS)
Nichols, M. E.
1976-01-01
Test procedures, history, and plotted coefficient data are presented for an aero-loads investigation on the updated configuration-5 space shuttle launch vehicle at Mach numbers from 0.600 to 1.205. Six-component vehicle forces and moments, base and sting-cavity pressures, elevon hinge moments, wing-root bending and torsion moments, and normal shear force data were obtained. Full simulation of updated vehicle protuberances and attach hardware was employed.
Vandergriff, D.H.
1999-08-31
A hinge assembly is disclosed having a first leaf, a second leaf and linking member. The first leaf has a contact surface. The second leaf has a first contact surface and a second contact surface. The linking member pivotally connects to the first leaf and to the second leaf. The hinge assembly is capable of moving from a closed position to an open position. In the closed position, the contact surface of the first leaf merges with the first contact surface of the second leaf. In the open position, the contact surface of the first leaf merges with the second contact surface of the second leaf. The hinge assembly can include a seal on the contact surface of the first leaf. 8 figs.
Vandergriff, David Houston
1999-01-01
A hinge assembly having a first leaf, a second leaf and linking member. The first leaf has a contact surface. The second leaf has a first contact surface and a second contact surface. The linking member pivotally connects to the first leaf and to the second leaf. The hinge assembly is capable of moving from a closed position to an open position. In the closed position, the contact surface of the first leaf merges with the first contact surface of the second leaf. In the open position, the contact surface of the first leaf merges with the second contact surface of the second leaf. The hinge assembly can include a seal on the contact surface of the first leaf.
Inelastic seismic response of precast concrete frames with constructed plastic hinges
NASA Astrophysics Data System (ADS)
Sucuoglu, H.
1995-07-01
A modified seismic design concept is introduced for precast concrete frames in which beam plastic hinges with reduced yield capacities are constructed away from the precast beam-column connections arranged at the column faces. Plastic hinge location and yield capacity are employed as the basic parameters of an analytical survey in which the inelastic dynamic responses of a conventional precast frame and its modified counterparts are calculated and compared under two earthquake excitations by using a general purpose computer program for dynamic analysis of inelastic frames (left bracket) 1, 2 (right bracket). An optimum design is obtained by providing plastic hinges on precast beams located at one depth away from the beam ends, in which primary (negative) bending moment yield capacities are reduced between one-third and one-quarter of the beam design end moments. With such plastic hinge configurations, precast beam-column connections at the column faces can be designed to remain elastic under strong earthquake excitations.
Origami-Inspired Folding of Thick, Rigid Panels
NASA Technical Reports Server (NTRS)
Trease, Brian P.; Thomson, Mark W.; Sigel, Deborah A.; Walkemeyer, Phillip E.; Zirbel, Shannon; Howell, Larry; Lang, Robert
2014-01-01
To achieve power of 250 kW or greater, a large compression ratio of stowed-to-deployed area is needed. Origami folding patterns were used to inspire the folding of a solar array to achieve synchronous deployment; however, origami models are generally created for near-zero-thickness material. Panel thickness is one of the main challenges of origami-inspired design. Three origami-inspired folding techniques (flasher, square twist, and map fold) were created with rigid panels and hinges. Hinge components are added to the model to enable folding of thick, rigid materials. Origami models are created assuming zero (or near zero) thickness. When a material with finite thickness is used, the panels are required to bend around an increasingly thick fold as they move away from the center of the model. The two approaches for dealing with material thickness are to use membrane hinges to connect the panels, or to add panel hinges, or hinges of the same thickness, at an appropriate width to enable folding.
Hinged external fixation of the elbow.
Chen, Neal C; Julka, Abhishek
2010-08-01
Hinged external fixation of the elbow provides the advantages of static fixation with the benefits of continued motion through the joint. Indications for the use of this method of fixation include traumatic instability, distraction interposition arthroplasty, instability after contracture release, and instability after excision of heterotopic ossification. Orthopedic surgeons should be familiar with hinged fixators and their application when faced with an unstable ulnohumeral joint. 2010 Elsevier Inc. All rights reserved.
Molecular mechanics of 30S subunit head rotation.
Mohan, Srividya; Donohue, John Paul; Noller, Harry F
2014-09-16
During ribosomal translocation, a process central to the elongation phase of protein synthesis, movement of mRNA and tRNAs requires large-scale rotation of the head domain of the small (30S) subunit of the ribosome. It has generally been accepted that the head rotates by pivoting around the neck helix (h28) of 16S rRNA, its sole covalent connection to the body domain. Surprisingly, we observe that the calculated axis of rotation does not coincide with the neck. Instead, comparative structure analysis across 55 ribosome structures shows that 30S head movement results from flexing at two hinge points lying within conserved elements of 16S rRNA. Hinge 1, although located within the neck, moves by straightening of the kinked helix h28 at the point of contact with the mRNA. Hinge 2 lies within a three-way helix junction that extends to the body through a second, noncovalent connection; its movement results from flexing between helices h34 and h35 in a plane orthogonal to the movement of hinge 1. Concerted movement at these two hinges accounts for the observed magnitudes of head rotation. Our findings also explain the mode of action of spectinomycin, an antibiotic that blocks translocation by binding to hinge 2.
Molecular mechanics of 30S subunit head rotation
Mohan, Srividya; Donohue, John Paul; Noller, Harry F.
2014-01-01
During ribosomal translocation, a process central to the elongation phase of protein synthesis, movement of mRNA and tRNAs requires large-scale rotation of the head domain of the small (30S) subunit of the ribosome. It has generally been accepted that the head rotates by pivoting around the neck helix (h28) of 16S rRNA, its sole covalent connection to the body domain. Surprisingly, we observe that the calculated axis of rotation does not coincide with the neck. Instead, comparative structure analysis across 55 ribosome structures shows that 30S head movement results from flexing at two hinge points lying within conserved elements of 16S rRNA. Hinge 1, although located within the neck, moves by straightening of the kinked helix h28 at the point of contact with the mRNA. Hinge 2 lies within a three-way helix junction that extends to the body through a second, noncovalent connection; its movement results from flexing between helices h34 and h35 in a plane orthogonal to the movement of hinge 1. Concerted movement at these two hinges accounts for the observed magnitudes of head rotation. Our findings also explain the mode of action of spectinomycin, an antibiotic that blocks translocation by binding to hinge 2. PMID:25187561
Friesenbichler, Joerg; Maurer-Ertl, Werner; Sadoghi, Patrick; Lovse, Thomas; Windhager, Reinhard; Leithner, Andreas
2012-03-01
The effects of systemic metal ion exposure in patients with implants made of common prosthetic alloys continue to be a matter of concern. The aim of the study was to determine the measurement values of cobalt (Co), chromium (Cr) and molybdenum (Mo) in serum following rotating-hinge knee arthroplasty. Blood was taken from 25 patients [mean follow-up 35 (range nine to 67) months] treated with megaprostheses (n=17) or standard rotating-hinge devices (n=8) and analysed using electrothermal graphite furnace atomic absorption spectrometry (ET-ASS). Determining the concentrations of metal ions following rotating-hinge knee arthroplasty revealed increments for Co and Cr but not Mo. Metal ion release was significantly higher in patients with megaprostheses compared to a standard rotating-hinge knee device (Co p=0,024; Cr p=0.025). The authors believe there might be an additional metal ion release from the surface of the prosthesis and not only from the articulating surfaces because, in cases of rotating-hinge knee prosthesis, there is a metal-on-polyethylene articulation and not a direct metal-on-metal junction. Nevertheless, long-term studies are required to determine adverse effects of Co, Cr and Mo following total hip replacement and total knee arthroplasty.
Understanding protein lids: kinetic analysis of active hinge mutants in triosephosphate isomerase.
Sun, J; Sampson, N S
1999-08-31
In previous work we tested what three amino acid sequences could serve as a protein hinge in triosephosphate isomerase [Sun, J., and Sampson, N. S. (1998) Protein Sci. 7, 1495-1505]. We generated a genetic library encoding all 8000 possible 3 amino acid combinations at the C-terminal hinge and selected for those combinations of amino acids that formed active mutants. These mutants were classified into six phylogenetic families. Two families resembled wild-type hinges, and four families represented new types of hinges. In this work, the kinetic characteristics and thermal stabilities of mutants representing each of these families were determined in order to understand what properties make an efficient protein hinge, and why all of the families are not observed in nature. From a steady-state kinetic analysis of our mutants, it is clear that the partitioning between protonation of intermediate to form product and intermediate release from the enzyme surface to form methylglyoxal (a decomposition product) is not affected. The two most impaired mutants undergo a change in rate-limiting step from enediol formation to dihydroxyacetone phosphate binding. Thus, it appears that k(cat)/K(m)'s are reduced relative to wild type as a result of slower Michaelis complex formation and dissociation, rather than increased loop opening speed.
Evading pre-existing anti-hinge antibody binding by hinge engineering
Kim, Hok Seon; Kim, Ingrid; Zheng, Linda; Vernes, Jean-Michel; Meng, Y. Gloria; Spiess, Christoph
2016-01-01
ABSTRACT Antigen-binding fragments (Fab) and F(ab′)2 antibodies serve as alternative formats to full-length anti-bodies in therapeutic and immune assays. They provide the advantage of small size, short serum half-life, and lack of effector function. Several proteases associated with invasive diseases are known to cleave antibodies in the hinge-region, and this results in anti-hinge antibodies (AHA) toward the neoepitopes. The AHA can act as surrogate Fc and reintroduce the properties of the Fc that are otherwise lacking in antibody fragments. While this response is desired during the natural process of fighting disease, it is commonly unwanted for therapeutic antibody fragments. In our study, we identify a truncation in the lower hinge region of the antibody that maintains efficient proteolytic cleavage by IdeS protease. The resulting neoepitope at the F(ab′)2 C-terminus does not have detectable binding of pre-existing AHA, providing a practical route to produce F(ab′)2 in vitro by proteolytic digestion when the binding of pre-existing AHA is undesired. We extend our studies to the upper hinge region of the antibody and provide a detailed analysis of the contribution of C-terminal residues of the upper hinge of human IgG1, IgG2 and IgG4 to pre-existing AHA reactivity in human serum. While no pre-existing antibodies are observed toward the Fab of IgG2 and IgG4 isotype, a significant response is observed toward most residues of the upper hinge of human IgG1. We identify a T225L variant and the natural C-terminal D221 as solutions with minimal serum reactivity. Our work now enables the production of Fab and F(ab′)2 for therapeutic and diagnostic immune assays that have minimal reactivity toward pre-existing AHA. PMID:27606571
Soft tissue management of orbitotemporal neurofibromatosis.
Singhal, Dhruv; Chen, Yi-Chieh; Chen, Yu-Ray; Chen, Philip Kuo-Ting; Tsai, Yueh-Ju
2013-01-01
The aim of this study was to provide an overview of a single-institution, 30-year surgical experience with the soft tissue management of orbitotemporal neurofibromatosis. Lessons learned are highlighted in case presentations. From 1981 to 2011, all patients who presented to the Chang Gung Memorial Hospital Craniofacial Center with craniofacial neurofibromatosis and orbitotemporal involvement were retrospectively reviewed. The medical records of those patients who underwent surgical correction were reviewed for age, extent of involvement, procedures performed, histologic confirmation, and acute complications. All patients were grouped according to the Jackson Classification. The electronic photobank was queried to evaluate results. Thirty-five patients presented to our center with orbitotemporal neurofibromatosis during the study period. Thirty-one patients underwent surgical management of their disease. The average age was 25 years (range 4 to 57 years). Over half of our patients (n = 18) presented with concomitant disease of the cheek. The 2 most common procedures performed were lateral canthopexy (n = 24) and upper eyelid excision (n = 24). The only acute complication recorded was a postoperative hematoma on the fourth postoperative day following simultaneous lateral canthopexy and upper eyelid excision which required operative evacuation. In orbitotemporal neurofibromatosis, tissue hyperextensibility and tumor weight adversely affect outcomes. Treatment of concomitant disease of the cheek should be prioritized in order to provide periorbital support prior to addressing the delicate structures of the eyelids. Preservation of the lateral canthal unit and levator muscle, despite neurofibroma infiltration, is critical to maximize outcomes following debulking procedures of the eyelid and orbit.
Magnetic second-order topological insulators and semimetals
NASA Astrophysics Data System (ADS)
Ezawa, Motohiko
2018-04-01
We propose magnetic second-order topological insulators (SOTIs). First, we study a three-dimensional model. It is pointed out that the previously proposed topological hinge insulator has actually surface states along the [001] direction in addition to hinge states. We gap out these surface states by introducing magnetization, obtaining a SOTI only with hinge states. The bulk topological number is the Z2 index protected by the combined symmetry of the fourfold rotation and the inversion symmetry. We next study two-dimensional magnetic SOTIs, where the corner states are robust also in the presence of the magnetization. Finally, we construct a magnetic second-order topological semimetal by layering the two-dimensional magnetic SOTIs, where hinge-arc states are robust also in the presence of the magnetization.
Kikuchi, Y; Tamiya, N
1987-01-01
The proteins in the hinge ligaments of molluscan bivalves were subjected to chemotaxonomic studies according to their amino acid compositions. The hinge-ligament protein is a new class of structure proteins, and this is the first attempt to introduce chemical taxonomy into the systematics of bivalves. The hinge-ligament proteins from morphologically close species, namely mactra (superfamily Mactracea) or scallop (family Pectinidae) species, showed high intraspecific homology in their compositions. On the other hand, inconsistent results were obtained with two types of ligament proteins in pearl oyster species (genus Pinctada). The results of our chemotaxonomic analyses were sometimes in good agreement with the morphological classifications and sometimes inconsistent, implying a complicated phylogenetic relationship among the species. PMID:3593265
Study on Transverse Load Distribution of Hinged Hollow Beam
NASA Astrophysics Data System (ADS)
Wang, Weiyue; Zhang, Chao; Wan, Shui
2017-11-01
The bridge is a kind of space structure, when the car load on a part of the bridge, the impact of its load will be transmitted to the surrounding. In this paper, the hinge plate method is used to calculate and analyze the simply supported hollow slab of a certain arch bridge. Considering the hinge plate mounting method is suitable for pouring concrete bridge connecting the longitudinal tongue and groove joints, horizontal beams fabricated separate beam only in the middle between the free flaps or reinforced with steel connection. Therefore, the transverse analysis and calculation of the superstructure of box girder are carried out by using hinge plate method. And mechanical analysis of the transverse beam with finite element software MIDAS Civil grillage method.
NASA Astrophysics Data System (ADS)
Pavlenko, Olga V.; Pigusov, Evgeny A.
2018-05-01
The paper discusses the approach of numerical simulation of the boundary layer control (BLC) on deflected flap for suppression of flow separation. Computational investigations were carried out using a program based on numerically solving the Reynolds averaged Navier-Stokes equations. The aim of this work is numerical investigation of the aerodynamic loads and hinge moments of the flap with BLC with influence of the walls of the wind tunnel. We have made a calculation of the airfoil section with flap deflected by 20° and 60° with variation of blowing momentum coefficient of Cμ=0÷0.1. The comparison of the calculation results with the experimental values of lift coefficient, pitching moment and pressure coefficient is presented. The pressure distribution on all surface of the wing and the threedimensional flow pattern of the wing with BLC, influence of the walls of the wind tunnel and the aerodynamic loads and hinge moments of the BLC flap are given. It is shown that the 20° flap increases the jet momentum coefficient from Cμ=0 to Cμ=0.1, leads to an increase of the hinge moment coefficient almost in 2 times, and the 60° flap increases the jet momentum coefficient from Cμ=0 to Cμ=0.113, leads to an increase of the hinge moment coefficient almost 3.5 times. The magnitude of the hinge moment on the flap with BLC rises due to the increase of the total aerodynamic force acting on the flap. As a result, the jet blowing on the plain flap leads to the significant increase of the hinge moment that must be considered when designing the high-lift devices with BLC.
Hirst, Deborah V.L.; Dunn, Kevin H.; Shulman, Stanley A.; Hammond, Duane R.; Sestito, Nicholas
2015-01-01
Exposures to diacetyl, a primary ingredient of butter flavoring, have been shown to cause respiratory disease among workers who mix flavorings. This study focused on evaluating ventilation controls designed to reduce emissions from the flavor mixing tanks, the major source of diacetyl in the plants. Five exhaust hood configurations were evaluated in the laboratory: standard hinged lid-opened, standard hinged lid-closed, hinged lid-slotted, dome with 38-mm gap, and dome with 114-mm gap. Tracer gas tests were performed to evaluate quantitative capture efficiency for each hood. A perforated copper coil was used to simulate an area source within the 1.2-meter diameter mixing tank. Capture efficiencies were measured at four hood exhaust flow rates (2.83, 5.66, 11.3, and 17.0 cubic meters per minute) and three cross draft velocities (0, 30, and 60 meters per minute). All hoods evaluated performed well with capture efficiencies above 90% for most combinations of exhaust volume and cross drafts. The standard hinged lid was the least expensive to manufacture and had the best average capture efficiency (over 99%) in the closed configuration for all exhaust flow rates and cross drafts. The hinged lid-slotted hood had some of the lowest capture efficiencies at the low exhaust flow rates compared to the other hood designs. The standard hinged lid performed well, even in the open position, and it provided a flexible approach to controlling emissions from mixing tanks. The dome hood gave results comparable to the standard hinged lid but it is more expensive to manufacture. The results of the study indicate that emissions from mixing tanks used in the production of flavorings can be controlled using simple inexpensive exhaust hoods. PMID:24649880
Aerodynamic analysis of seamless horizontal stabilizer
NASA Astrophysics Data System (ADS)
Nithya, S.; Kanimozhi, S.
2017-05-01
This project presents an investigative view into the concept of seamless aeroelastic wing and hingeless flexible trailing edge. Wings are designed to provide maximum lift and minimal drag and weight. But with conventional wings where rivets are used and the control surfaces are separately hinged, parasite drag comes into play. This project is about analysing a smooth seamless wing with hinge-less flexible trailing edge. This type of wing reduces the drag considerably and the hinge-less trailing edge leads to a minimal control demand and reduces the noise produced when the aircraft comes for landing. Seamless aeroelastic wing will function as an integrated one piece lifting and control surface. It has been designed to enhance a desirable wing camber for control by deflecting a hinge-less flexible trailing edge part instead of a traditional hinged control surface. This kind of flexible wing can be achieved either by a curved beam and disc actuation mechanism or by piezo-electric materials, whose shape change can be achieved by electricity. The intent of this project is to analyze the effects of introducing the concept of Seamless Wing to the horizontal stabilizer. While the removal of rivets and serrations that hinge the elevators to the stabilizer reduces the overall drag by a reasonable value, the overall concept of a control surface-less stabilizer where the maneuvers are done by deflecting the trailing edge offers better maneuverability.
Kinematics analysis on hinges of robot arm gripper for harmful chemical handling
NASA Astrophysics Data System (ADS)
Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Mustafa, Nurul Fahimah; Daud, Mohd Hisam
2017-09-01
The development of manufacturing industry is booming the application of industrial robot, and proportional to the use of robot arm. Some of the purpose of robot arm gripper is to sort things and place to the proper place. And some of the things are harmful to human, such as harmful chemical. By using robot arm to do picking and placing, it is expected to replace human tasks, as well as to reduce human from the harmful job. The problem of the robot arm gripper, most likely the problem of hinge, thus the analysis on the hinges of robot arm gripper to prevent claw is essential. By using robot arm, instead of human, is labored to do the harmful tasks and unexpected accident happen, costs and expenses in handling injured employee due to the harmful chemicals can be minimized. Thus the objective of this project is to make a kinematics analysis on the hinges of the robot arm gripper. Suitable material such as steel structure has also been selected for the construction of this hinges. This material has properties associated with compressive strength, fire resistance, corrosion and has a shape that is easy to move. Solid Works and ANSYS software is used to create animated movement on the design model and to detect deficiencies in the hinges. Detail methodology is described in this paper.
Platelet activation through a Bi-leaflet mechanical heart valve
NASA Astrophysics Data System (ADS)
Hedayat, Mohammadali; Borazjani, Iman
2016-11-01
Platelet activation is one of the major drawbacks of the Mechanical Heart Valves (MHVs) which can increase the risk of thrombus formation in patients. The platelet activation in MHVs can be due to the abnormal shear stress during the systole, the backward leakage flow during the diastole, and the flow through the hinge region. We investigate the contribution of each of the above mechanism to the activation of platelets in MHVs by performing simulations of the flow through the MHV and in the hinge region. The large scale heart valve simulations are performed in a straight aorta using a sharp interface curvilinear immersed boundary method along with a strong-coupling algorithm under physiological flow conditions. In addition, in order to perform the simulation of hinge region the flow field boundary conditions are obtained from the largescale simulations during a whole cardiac cycle. In order to investigate the role of hinge flow on platelet activation in MHVs, a 23mm St. Jude Medical Regent valve hinge with three different gap sizes is tested along with different platelet activation models to ensure the consistency of our results with different activation models. We compare the platelet activation of the hinge region against the bulk of the flow during one cardiac cycle. This work is supported by the American Heart Association Grant 13SDG17220022, and the computational resources were partly provided by Center for Computational Research (CCR) at University at Buffalo.
Hinged Capsulotomy – Does it Decrease Floaters After Yttrium Aluminum Garnet Laser Capsulotomy?
Alipour, Fatemeh; Jabbarvand, Mahmoud; Hashemian, Hesam; Hosseini, Simindokht; Khodaparast, Mehdi
2015-01-01
Objectives: The objective was to compare conventional circular yttrium aluminum garnet (YAG) laser capsulotomy with hinged capsulotomy to manage posterior capsular opacification (PCO). Materials and Methods: This prospective, randomized clinical trial enrolled pseudophakic patients with visually significant posterior capsule opacification. Patients were randomized to undergo posterior YAG laser capsulotomy with either conventional circular technique or a new technique with an inferior hinge. At 1-month postoperatively, patients were asked if they had any annoying floaters and the responses were compared between groups. P < 0.05 was considered statistically significant. Results: A total of 83 patients were enrolled. Forty-three patients underwent hinged posterior YAG capsulotomy and 40 patients underwent routine circular capsulotomy. At 1-month postoperatively, there was a statistically significant decrease in annoying floaters in the group that underwent circular capsulotomy (P = 0.02). There was no statistically significant association in the total energy delivered (P = 0.4) or the number of spots (P = 0.2) and patient perception of annoying floaters. Conclusion: Hinged YAG capsulotomy was effective at decreasing the rate of floaters in patients with PCO. PMID:26180476
Hinged Capsulotomy--Does it Decrease Floaters After Yttrium Aluminum Garnet Laser Capsulotomy?
Alipour, Fatemeh; Jabbarvand, Mahmoud; Hashemian, Hesam; Hosseini, Simindokht; Khodaparast, Mehdi
2015-01-01
The objective was to compare conventional circular yttrium aluminum garnet (YAG) laser capsulotomy with hinged capsulotomy to manage posterior capsular opacification (PCO). This prospective, randomized clinical trial enrolled pseudophakic patients with visually significant posterior capsule opacification. Patients were randomized to undergo posterior YAG laser capsulotomy with either conventional circular technique or a new technique with an inferior hinge. At 1-month postoperatively, patients were asked if they had any annoying floaters and the responses were compared between groups. P < 0.05 was considered statistically significant. A total of 83 patients were enrolled. Forty-three patients underwent hinged posterior YAG capsulotomy and 40 patients underwent routine circular capsulotomy. At 1-month postoperatively, there was a statistically significant decrease in annoying floaters in the group that underwent circular capsulotomy (P = 0.02). There was no statistically significant association in the total energy delivered (P = 0.4) or the number of spots (P = 0.2) and patient perception of annoying floaters. Hinged YAG capsulotomy was effective at decreasing the rate of floaters in patients with PCO.
Mechanical energy storage device for hip disarticulation
NASA Technical Reports Server (NTRS)
Vallotton, W. C. (Inventor)
1977-01-01
An artificial leg including a trunk socket, a thigh section hingedly coupled to the trunk socket, a leg section hingedly coupled to the thigh section and a foot section hingedly coupled to the leg section is outlined. A mechanical energy storage device is operatively associated with the artificial leg for storage and release of energy during the normal walking stride of the user. Energy is stored in the mechanical energy storage device during a weight-bearing phase of the walking stride when the user's weight is on the artificial leg. Energy is released during a phase of the normal walking stride, when the user's weight is removed from the artificial leg. The stored energy is released from the energy storage device to pivot the thigh section forwardly about the hinged coupling to the trunk socket.
A fully redundant power hinge for LANDSAT-D appendages
NASA Technical Reports Server (NTRS)
Mamrol, F. E.; Matteo, D. N.
1981-01-01
The configuration and testing of a power driven hinge for deployment of the solar array and antenna boom for the LANDSAT-D spacecraft is discussed. The hinge is fully mechanically and electrically redundant and, thereby, can sustain a single point failure of any one motor (or its power supply), speed reducer, or bearing set without loss of its ability to function. This design utilizes the capability of the stepper motor drive to remove the flexibility of the drive train from the joint stiffness equation when the hinge is loaded against its stop. This feature precludes gapping of the joint under spacecraft maneuver loads even in the absence of a latching feature. Thus, retraction is easily accomplished by motor reversal without the need for a solenoid function to remove the latch.
Adaptive fiber optics collimator based on flexible hinges.
Zhi, Dong; Ma, Yanxing; Ma, Pengfei; Si, Lei; Wang, Xiaolin; Zhou, Pu
2014-08-20
In this manuscript, we present a new design for an adaptive fiber optics collimator (AFOC) based on flexible hinges by using piezoelectric stacks actuators for X-Y displacement. Different from traditional AFOC, the new structure is based on flexible hinges to drive the fiber end cap instead of naked fiber. We fabricated a real AFOC based on flexible hinges, and the end cap's deviation and resonance frequency of the device were measured. Experimental results show that this new AFOC can provide fast control of tip-tilt deviation of the laser beam emitting from the end cap. As a result, the fiber end cap can support much higher power than naked fiber, which makes the new structure ideal for tip-tilt controlling in a high-power fiber laser system.
CALUTRON ASSEMBLING AND DISASSEMBLING APPARATUS
Andrews, R.E.
1959-01-27
A closure plate assembly is presented for a calutron tank. Due to the size and weight of the calutron tank a special face plate, hinges and latch construction are required. The salient feature of the invention is the provision of a face plate carrying the ion separating niechanism and adapted to close an open side of a calutron tank. A spring-type hinge secured to the face plate at one end prevents injury to the sealing gasket as the face plate is inserted and withdrawn. In additions a hinged support for the face plate comprises readily separable hinge elements, so that the face plate may first be swung outwardly from its operative position far enough to clear the ion separating meehanism carried thereby, and may thereafter be elevated and transported by a convcntional overhead crane.
Linear scleroderma associated with ptosis and motility disorders.
Suttorp-Schulten, M S; Koornneef, L
1990-01-01
A case is reported in which an 11-year-old girl developed progressive ptosis and a subsequent motility disorder of the right eye. The diagnosis linear scleroderma en coup de sabre was established. Atrophy of the upper levator palpebral and superior rectus muscle could be shown on CT scan. Images PMID:2223709
USDA-ARS?s Scientific Manuscript database
Despite cleft palate repair, velopharyngeal competence is not achieved in ~ 15% of patients, often necessitating secondary surgical correction. Velopharyngeal competence postrepair may require the conversion of levator veli palatini muscle fibers from injury-susceptible type 2 fibers to injury-resi...
The Urethral Rhabdosphincter, Levator Ani Muscle, and Perineal Membrane: A Review
Hinata, Nobuyuki; Murakami, Gen
2014-01-01
Detailed knowledge of the anatomy of the rhabdosphincter and adjacent tissues is mandatory during urologic surgery to ensure reliable oncologic and functional outcomes. To characterize the levator ani (LA) function for the urethral sphincter, we described connective tissue morphology between the LA and urethral rhabdosphincter. The interface tissue between the LA and rhabdosphincter area in males contained abundant irregularly arrayed elastic fibers and smooth muscles. The male rhabdosphincter was positioned alongside the LA to divide the elevation force and not in-series along the axis of LA contraction. The male perineal membrane was thin but solid and extends along the inferior margin or bottom of the rhabdosphincter area. In contrast, the female rhabdosphincter, including the compressor urethrae and urethrovaginal sphincter muscles, was embedded in the elastic fiber mesh that is continuous with the thick, multilaminar perineal membrane. The inferomedial edge of the female LA was attached to the upper surface of the perineal membrane and not directly attached to the rhabdosphincter. We presented new diagrams showing the gender differences in topographical anatomy of the LA and rhabdosphincter. PMID:24877147
[Eyelid retraction of neurologic origin: Report of three cases].
Cartier R, Luis; Guzmán S, Jorge; Pasquali F, Renzo
2017-02-01
Eyelid retraction, has received limited attention and it has passively been interpreted as the result of an overactive levator palpebrae superioris muscle secondary to midbrain injury. However, eyelid retractions can occur in other neurological diseases, not directly related with the midbrain. We report three patients who developed eyelid retraction. One patient had a bilateral eyelid retraction, related with Creutzfeldt-Jakob disease (CJD). Another patient had a unilateral right eyelid retraction associated with a thalamic-mesencephalic infarct. The third patient had a bilateral pontine infarction on magnetic resonance imaging. In the patient with CJD, eyelid retraction did not subside. Among patients with infarctions, the retraction persisted after focal symptoms had subsided, showing an evolution that was apparently independent of the basic process. The analysis of these patients allows us to conclude that the pathogenesis of eyelid retraction includes supranuclear mechanisms in both the development and maintenance of the phenomenon. Unilateral or bilateral eyelid retraction does not alter the normal function of eyelid, which ever had normal close eye blink. In these reported cases, a hyperactivity of levator palpebrae superioris muscle was clinically ruled out.
BAF57 Modulation of Androgen Receptor Action and Prostate Cancer Progression
2007-12-01
mapped the AR binding site on BAF57 to the N-terminus (proline-rich region). Furthermore, the DBD and hinge region of AR also appear to play a...Accomplishments of Task 1: BAF57 binds to DNA binding domain ( DBD ) and hinge region of AR As outlined in the initial proposal, the first task...the above construct are the well-characterized zinc finger DNA binding domain ( DBD ) and the hinge region. Given the significant role of these two
BAF57 Modulation of Androgen Receptor Action and Prostate Cancer Progression
2006-12-01
has fine mapped the AR binding site on BAF57 to the N-terminus (proline-rich region). Furthermore, the DBD and hinge region of AR also appear to...Accomplishments of Task 1: BAF57 binds to DNA binding domain ( DBD ) and hinge region of AR As outlined in the initial proposal, the first task was to...construct are the well-characterized zinc finger DNA binding domain ( DBD ) and the hinge region. Given the significant role of these two domains in AR
Wire-Strain-Gage Hinge-Moment Indicators for Use in Tests of Airplane Models
NASA Technical Reports Server (NTRS)
Edwards, Howard B.
1944-01-01
The design and construction of various forms of strain-gage spring units and hinge-moment assemblies are discussed with particular reference to wind-tunnel test, although the indicators may be used equally well in flight tests. Strain-gage specifications are given, and the techniques of their application and use are described briefly. Testing, calibration and operation of hinge-moment indicators are discussed and precautions necessary for successful operation are stressed. Difficulties that may be encountered are summarized along with the possible causes.
Grzesik, Paul; Kreuchwig, Annika; Rutz, Claudia; Furkert, Jens; Wiesner, Burkhard; Schuelein, Ralf; Kleinau, Gunnar; Gromoll, Joerg; Krause, Gerd
2015-01-01
The human lutropin (hLH)/choriogonadotropin (hCG) receptor (LHCGR) can be activated by binding two slightly different gonadotropic glycoprotein hormones, choriogonadotropin (CG) – secreted by the placenta, and lutropin (LH) – produced by the pituitary. They induce different signaling profiles at the LHCGR. This cannot be explained by binding to the receptor’s leucine-rich-repeat domain (LRRD), as this binding is similar for the two hormones. We therefore speculate that there are previously unknown differences in the hormone/receptor interaction at the extracellular hinge region, which might help to understand functional differences between the two hormones. We have therefore performed a detailed study of the binding and action of LH and CG at the LHCGR hinge region. We focused on a primate-specific additional exon in the hinge region, which is located between LRRD and the serpentine domain. The segment of the hinge region encoded by exon10 was previously reported to be only relevant to hLH signaling, as the exon10-deletion receptor exhibits decreased hLH signaling, but unchanged hCG signaling. We designed an advanced homology model of the hormone/LHCGR complex, followed by experimental characterization of relevant fragments in the hinge region. In addition, we examined predictions of a helical exon10-encoded conformation by block-wise polyalanine (helix supporting) mutations. These helix preserving modifications showed no effect on hormone-induced signaling. However, introduction of a structure-disturbing double-proline mutant LHCGR-Q303P/E305P within the exon10-helix has, in contrast to exon10-deletion, no impact on hLH, but only on hCG signaling. This opposite effect on signaling by hLH and hCG can be explained by distinct sites of hormone interaction in the hinge region. In conclusion, our analysis provides details of the differences between hLH- and hCG-induced signaling that are mainly determined in the L2-beta loop of the hormones and in the hinge region of the receptor. PMID:26441830
NASA Technical Reports Server (NTRS)
Miller, Eric J.; Cruz, Josue; Lung, Shun-Fat; Kota, Sridhar; Ervin, Gregory; Lu, Kerr-Jia; Flick, Pete
2016-01-01
A seamless adaptive compliant trailing edge (ACTE) flap was demonstrated in flight on a Gulfstream III aircraft at the NASA Armstrong Flight Research Center. The trailing edge flap was deflected between minus 2 deg up and plus 30 deg down in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The interface hardware instrumentation layout and load calibration are discussed. Twenty-one applied calibration test load cases were developed for each individual fitting. The 2-sigma residual errors for the hinge moment was calculated to be 2.4 percent, and for normal force was calculated to be 7.3 percent. The hinge moment and normal force generated by the ACTE flap with a hinge point located at 26-percent wing chord were measured during steady state and symmetric pitch maneuvers. The loads predicted from analysis were compared to the loads observed in flight. The hinge moment loads showed good agreement with the flight loads while the normal force loads calculated from analysis were over-predicted by approximately 20 percent. Normal force and hinge moment loads calculated from the pressure sensors located on the ACTE showed good agreement with the loads calculated from the installed strain gages.
A new germfree chicken cage--characteristics and use.
MILLER, H T; LUCKEY, T D
1962-01-01
A new germfree chicken cage for rearing chicks up to 3 or 4 weeks of age has been designed and is in use at the University of Missouri. The cage and the accessory parts, the small magnet and hinged door, the "Bactytector," the built-in air filter assembly, and the glass top with connecting air outlet filter have been described in detail. The complete operating procedure for sterilizing the cage and diet and the method of adding sterile embryonated eggs have been outlined. Data on the effectiveness of the cage as a physical barrier to microbes have been presented.
Gao, Wenqing; Kearbey, Jeffrey D.; Nair, Vipin A.; Chung, Kiwon; Parlow, A. F.; Miller, Duane D.; Dalton, James T.
2007-01-01
Tissue-selective androgen receptor modulators (SARMs) demonstrate tissue selectivity in both castrated and intact male rats, behaving as partial agonists in androgenic tissues (i.e. prostate and seminal vesicle), but full agonists in anabolic tissues (i.e. levator ani muscle). The partial agonist activity of SARMs (compounds S-1 and S-4) in the prostate of intact rats suggested that SARM could be used for androgen suppression in the treatment of benign prostate hyperplasia (BPH). This study was designed to explore the mechanisms of action of SARM and to characterize the tissue selectivity of S-1 in intact male rats compared with that of hydroxyflutamide (antiandrogen) and finasteride (5α-reductase inhibitor), two major drugs used for androgen suppression treatment of BPH. In intact male rats, S-1 (5, 10, and 25 mg/kg) selectively decreased the prostate weight with similar efficacy to finasteride (5 mg/kg), without affecting the levator ani muscle or increasing the plasma levels of testosterone, LH, and FSH. Hydroxyflutamide (0.5, 1, 5, 10, and 25 mg/kg), however, decreased both the prostate and levator ani muscle weights without any selectivity and increased plasma hormone levels in a dose-dependent manner. Furthermore, S-1 and S-4 showed very weak inhibitory effects toward transiently expressed type I and II human 5α-reductase (Ki, >20 µM) during in vitro assays. Therefore, although S-1 and finasteride showed very similar suppressive effects in the prostate of intact male rats, they decreased prostate size via different mechanisms of action. S-1 simply worked as androgen receptor partial agonist, whereas finasteride inhibited prostatic 5α-reductase. These studies indicate that SARMs may demonstrate clinical utility as single agent or combination therapy for BPH. PMID:15308613
Reference-tissue correction of T2-weighted signal intensity for prostate cancer detection
NASA Astrophysics Data System (ADS)
Peng, Yahui; Jiang, Yulei; Oto, Aytekin
2014-03-01
The purpose of this study was to investigate whether correction with respect to reference tissue of T2-weighted MRimage signal intensity (SI) improves its effectiveness for classification of regions of interest (ROIs) as prostate cancer (PCa) or normal prostatic tissue. Two image datasets collected retrospectively were used in this study: 71 cases acquired with GE scanners (dataset A), and 59 cases acquired with Philips scanners (dataset B). Through a consensus histology- MR correlation review, 175 PCa and 108 normal-tissue ROIs were identified and drawn manually. Reference-tissue ROIs were selected in each case from the levator ani muscle, urinary bladder, and pubic bone. T2-weighted image SI was corrected as the ratio of the average T2-weighted image SI within an ROI to that of a reference-tissue ROI. Area under the receiver operating characteristic curve (AUC) was used to evaluate the effectiveness of T2-weighted image SIs for differentiation of PCa from normal-tissue ROIs. AUC (+/- standard error) for uncorrected T2-weighted image SIs was 0.78+/-0.04 (datasets A) and 0.65+/-0.05 (datasets B). AUC for corrected T2-weighted image SIs with respect to muscle, bladder, and bone reference was 0.77+/-0.04 (p=1.0), 0.77+/-0.04 (p=1.0), and 0.75+/-0.04 (p=0.8), respectively, for dataset A; and 0.81+/-0.04 (p=0.002), 0.78+/-0.04 (p<0.001), and 0.79+/-0.04 (p<0.001), respectively, for dataset B. Correction in reference to the levator ani muscle yielded the most consistent results between GE and Phillips images. Correction of T2-weighted image SI in reference to three types of extra-prostatic tissue can improve its effectiveness for differentiation of PCa from normal-tissue ROIs, and correction in reference to the levator ani muscle produces consistent T2-weighted image SIs between GE and Phillips MR images.
Bukovsky, Antonin; Copas, Pleas; Caudle, Michael R; Cekanova, Maria; Dassanayake, Tamara; Asbury, Bridgett; Van Meter, Stuart E; Elder, Robert F; Brown, Jeffrey B; Cross, Stephanie B
2001-01-01
Background Pelvic floor disorders affect almost 50% of aging women. An important role in the pelvic floor support belongs to the levator ani muscle. The p27/kip1 (p27) protein, multifunctional cyclin-dependent kinase inhibitor, shows changing expression in differentiating skeletal muscle cells during development, and relatively high levels of p27 RNA were detected in the normal human skeletal muscles. Methods Biopsy samples of levator ani muscle were obtained from 22 symptomatic patients with stress urinary incontinence, pelvic organ prolapse, and overlaps (age range 38–74), and nine asymptomatic women (age 31–49). Cryostat sections were investigated for p27 protein expression and type I (slow twitch) and type II (fast twitch) fibers. Results All fibers exhibited strong plasma membrane (and nuclear) p27 protein expression. cytoplasmic p27 expression was virtually absent in asymptomatic women. In perimenopausal symptomatic patients (ages 38–55), muscle fibers showed hypertrophy and moderate cytoplasmic p27 staining accompanied by diminution of type II fibers. Older symptomatic patients (ages 57–74) showed cytoplasmic p27 overexpression accompanied by shrinking, cytoplasmic vacuolization and fragmentation of muscle cells. The plasma membrane and cytoplasmic p27 expression was not unique to the muscle cells. Under certain circumstances, it was also detected in other cell types (epithelium of ectocervix and luteal cells). Conclusions This is the first report on the unusual (plasma membrane and cytoplasmic) expression of p27 protein in normal and abnormal human striated muscle cells in vivo. Our data indicate that pelvic floor disorders are in perimenopausal patients associated with an appearance of moderate cytoplasmic p27 expression, accompanying hypertrophy and transition of type II into type I fibers. The patients in advanced postmenopause show shrinking and fragmentation of muscle fibers associated with strong cytoplasmic p27 expression. PMID:11696252
An agonist–antagonist cerebellar nuclear system controlling eyelid kinematics during motor learning
Sánchez-Campusano, Raudel; Gruart, Agnès; Fernández-Mas, Rodrigo; Delgado-García, José M.
2012-01-01
The presence of two antagonistic groups of deep cerebellar nuclei neurons has been reported as necessary for a proper dynamic control of learned motor responses. Most models of cerebellar function seem to ignore the biomechanical need for a double activation–deactivation system controlling eyelid kinematics, since most of them accept that, for closing the eyelid, only the activation of the orbicularis oculi (OO) muscle (via the red nucleus to the facial motor nucleus) is necessary, without a simultaneous deactivation of levator palpebrae motoneurons (via unknown pathways projecting to the perioculomotor area). We have analyzed the kinetic neural commands of two antagonistic types of cerebellar posterior interpositus neuron (IPn) (types A and B), the electromyographic (EMG) activity of the OO muscle, and eyelid kinematic variables in alert behaving cats during classical eyeblink conditioning, using a delay paradigm. We addressed the hypothesis that the interpositus nucleus can be considered an agonist–antagonist system controlling eyelid kinematics during motor learning. To carry out a comparative study of the kinetic–kinematic relationships, we applied timing and dispersion pattern analyses. We concluded that, in accordance with a dominant role of cerebellar circuits for the facilitation of flexor responses, type A neurons fire during active eyelid downward displacements—i.e., during the active contraction of the OO muscle. In contrast, type B neurons present a high tonic rate when the eyelids are wide open, and stop firing during any active downward displacement of the upper eyelid. From a functional point of view, it could be suggested that type B neurons play a facilitative role for the antagonistic action of the levator palpebrae muscle. From an anatomical point of view, the possibility that cerebellar nuclear type B neurons project to the perioculomotor area—i.e., more or less directly onto levator palpebrae motoneurons—is highly appealing. PMID:22435053
Djordjević, Boban; Novaković, Marijan; Milisavljević, Milan; Milićević, Sasa; Maliković, Aleksandar
2013-12-01
The detailed knowledge of the architecture of the upper eyelid is very important in numerous upper eyelid corrective surgeries. The article deals with the detailed anatomy of the major components of the upper lid, which are commonly seen in surgical practice. This study was conducted on 19 human cadavers (12 adults and 7 infants) without pathologic changes in the orbital region and eyelids. Anatomic microdissection of the contents of the orbita was performed bilaterally on 12 orbits from 6 unfixed cadavers (3 male and 3 female). Micromorphologic investigations of the orbital tissue were performed on 8 en bloc excised and formalin-fixed orbits of infant cadavers. Specimens were fixed according to the Duvernoy method. An intra-arterial injection of 5% mixture of melt formalin and black ink was administered into the carotid arterial system. Using routine fixation, decalcination, dehydration, illumination, impregnation and molding procedures in paraplast, specimens were prepared for cross-sections. The measurement of the muscle length and diameter in situ in 6 nonfixed cadavers (12 orbits) showed an average length of the levator palpbrae superioris (LPS) muscle body of the 42.0 +/- 1.41 mm on the right, and 40.3 +/- 1.63 mm on the left side. In all the cases, the LPS had blood supply from 4 different arterial systems: the lacrimal, supratrochlear, and supraorbital artery and muscle branches of the ophthalmic artery. The LPS muscle in all the specimens was supplied by the superior medial branch of the oculomotor nerve. The connective tissue associated with the LPS muscle contains two transverse ligaments: the superior (Whitnall's) and intermuscular transverse ligaments (ITL). The orbital septum in all the specimens originated from the arcus marginalis of the frontal bone, and consisted of two layers--the superficial and the inner layer. In addition, a detailed histological analysis revealed that the upper eyelid's crease was formed by the conjoined fascia including the fascia of the orbicularis muscle, the superficial layer of the orbital septum, and the aponeurosis of the LPS muscle, as well as the pretarsal fascia. The conducted study provided a valuable morphological basis for biomechanical and clinical considerations regarding blepharoptosis surgery.
Gas turbine combustor exit piece with hinged connections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charron, Richard C.; Pankey, William W.
2016-04-26
An exit piece (66) with an inlet throat (67) that conducts a combustion gas flow (36A) in a path (82) from a combustor (63) to an annular chamber (68) that feeds the first blade section (37) of a gas turbine (26). The exit piece further includes an outlet portion (69) that forms a circumferential segment of the annular chamber. The outlet portion interconnects with adjacent outlet portions by hinges (78A, 78B, 80A, 80B). Each hinge may have a hinge axis (82A, 82B) parallel to a centerline (21) of the turbine. Respective gas flows (36A) are configured by an assembly (60)more » of the exit pieces to converge on the feed chamber (68) into a uniform helical flow that drives the first blade section with minimal circumferential variations in force.« less
Investigation on adaptive wing structure based on shape memory polymer composite hinge
NASA Astrophysics Data System (ADS)
Yu, Yuemin; Li, Xinbo; Zhang, Wei; Leng, Jinsong
2007-07-01
This paper describes the design and investigation of the SMP composite hinge and the morphing wing structure. The SMP composite hinge was based on SMP and carbon fiber fabric. The twisting recoverability of it was investigated by heating and then cooling repeatedly above and below the Tg. The twisting recoverability characterized by the twisting angle. Results show that the SMP composite hinge have good shape recoverability, Recovery time has a great influence on the twisting recoverability. The twisting recovery ratio became large with the increment of recovery time. The morphing wing can changes shape for different tasks. For the advantages of great recovery force and stable performances, we adopt SMP composite hinge as actuator to apply into the structure of the wing which can realize draw back wings to change sweep angle according to the speed and other requirements of military airplanes. Finally, a series of simulations and experiments are performed to investigate the deformations of morphing wings have been performed successfully. It can be seen that the sweep angle change became large with the increment of initial angle. The area reduction became large with the increment of initial angle, but after 75° the area reduction became smaller and smaller. The deformations of the triangle wing became large with the increment of temperature. The area and the sweep angle of wings can be controlled by adjusting the stimulate temperature and the initial twisting angle of shape memory polymer composite hinge.
Kim, Seung-Nam; Park, Taewon; Lee, Sang-Hyun
2014-01-01
Damage of a 5-story framed structure was identified from two types of measured data, which are frequency response functions (FRF) and natural frequencies, using a finite element (FE) model updating procedure. In this study, a procedure to determine the appropriate weightings for different groups of observations was proposed. In addition, a modified frame element which included rotational springs was used to construct the FE model for updating to represent concentrated damage at the member ends (a formulation for plastic hinges in framed structures subjected to strong earthquakes). The results of the model updating and subsequent damage detection when the rotational springs (RS model) were used were compared with those obtained using the conventional frame elements (FS model). Comparisons indicated that the RS model gave more accurate results than the FS model. That is, the errors in the natural frequencies of the updated models were smaller, and the identified damage showed clearer distinctions between damaged and undamaged members and was more consistent with observed damage. PMID:24574888
NASA Astrophysics Data System (ADS)
Manning, Andrew H.; Bartley, John M.
1994-06-01
Much of the recent debate over low-angle normal faults exposed in metamorphic core complexes has centered on the rolling hinge model. The model predicts tilting of seismogenic high-angle normal faults to lower dips by footwall deformation in response to isostatic forces caused by footwall exhumation. This shallow brittle deformation should visibly overprint the mylonitic fabric in the footwall of a metamorphic core complex. The predicted style and magnitude of rolling hinge strain depends upon the macroscopic mechanism by which the footwall deforms. Two end-members have been proposed: subvertical simple shear and flexural failure. Each mechanism should generate a distinctive pattern of structures that strike perpendicular to the regional extension direction. Subvertical simple shear (SVSS) should generate subvertical faults and kink bands with a shear sense antithetic to the detachment. For an SVSS hinge, the hinge-related strain magnitude should depend only on initial fault dip; rolling hinge structures should shorten the mylonitic foliation by >13% for an initial fault dip of >30°. In flexural failure the footwall behaves as a flexed elastic beam that partially fails in response to bending stresses. Resulting structures include conjugate faults and kink bands that both extend and contract the mylonitic foliation. Extensional sets could predominate as a result of superposition of far-field and flexural stresses. Strain magnitudes do not depend on fault dip but depend on the thickness and radius of curvature of the flexed footwall beam and vary with location within that beam. Postmylonitic structures were examined in the footwall of the Raft River metamorphic core complex in northwestern Utah to test these predictions. Observed structures strike perpendicular to the regional extension direction and include joints, normal faults, tension-gash arrays, and both extensional and contractional kink bands. Aside from the subvertical joints, the extensional structures dip moderately to steeply and are mainly either synthetic to the detachment or form conjugate sets. Range-wide, the extensional structures accomplish about 4% elongation of the mylonitic foliation. Contractional structures dip steeply, mainly record shear antithetic to the detachment, and accomplish <1% contraction of the foliation. These observations are consistent with the presence of a rolling hinge in the Raft River Mountains, but a rolling hinge that reoriented a high-angle normal fault by SVSS is excluded. The pattern and magnitudes of strain favor hinge-related deformation mainly by flexural failure with a subordinate component of SVSS.
NASA Technical Reports Server (NTRS)
Runckel, Jack F.; Hieser, Gerald
1961-01-01
An investigation has been conducted at the Langley 16-foot transonic tunnel to determine the loading characteristics of flap-type ailerons located at inboard, midspan, and outboard positions on a 45 deg. sweptback-wing-body combination. Aileron normal-force and hinge-moment data have been obtained at Mach numbers from 0.80 t o 1.03, at angles of attack up to about 27 deg., and at aileron deflections between approximately -15 deg. and 15 deg. Results of the investigation indicate that the loading over the ailerons was established by the wing-flow characteristics, and the loading shapes were irregular in the transonic speed range. The spanwise location of the aileron had little effect on the values of the slope of the curves of hinge-moment coefficient against aileron deflection, but the inboard aileron had the greatest value of the slope of the curves of hinge-moment coefficient against angle of attack and the outboard aileron had the least. Hinge-moment and aileron normal-force data taken with strain-gage instrumentation are compared with data obtained with pressure measurements.
Rowley, James P.; Lewandowski, Edward F.; Groh, Edward F.
1976-01-01
Three cylindrical rollers are rotatably mounted equidistant from the center of a hollow tool head on radii spaced 120.degree. apart. Each roller has a thin flange; the three flanges lie in a single plane to form an internal circumferential rib in a rotating tubular workpiece. The tool head has two complementary parts with two rollers in one part of the head and one roller in the other part; the two parts are joined by a hinge. A second hinge, located so the rollers are between the two hinges, connects one of the parts to a tool bar mounted in a lathe tool holder. The axes of rotation of both hinges and all three rollers are parallel. A hole exposing equal portions of the three roller flanges is located in the center of the tool head. The two hinges permit the tool head to be opened and rotated slightly downward, taking the roller flanges out of the path of the workpiece which is supported on both ends and rotated by the lathe. The parts of the tool head are then closed on the workpiece so that the flanges are applied to the workpiece and form the rib. The tool is then relocated for forming of the next rib.
Jaeger, Gayle H; Wosar, Marc A; Marcellin-Little, Denis J; Lascelles, B Duncan X
2005-08-15
To describe placement of hinged transarticular external fixation (HTEF) frames and evaluate their ability to protect the primary repair of unstable joints while allowing joint mobility in dogs and cats. Retrospective study. 8 cats and 6 dogs. HTEF frames were composed of metal or epoxy connecting rods and a hinge. Measurements of range of motion of affected and contralateral joints and radiographs were made after fixator application and removal. 9 animals (4 cats and 5 dogs) had tarsal and 5 (4 cats and 1 dog) had stifle joint injuries. Treatment duration ranged from 45 to 100 days (median, 57 days). Ranges of motion in affected stifle and tarsal joints were 57% and 72% of control while HTEF was in place and 79% and 84% of control after frame removal. Complications were encountered in 3 cats and 2 dogs and included breakage of pins and connecting rods, hinge loosening, and failure at the hinge-epoxy interface. HTEF in animals with traumatic joint instability provided adjunctive joint stabilization during healing and protection of the primary repair and maintained joint motion during healing, resulting in early weight bearing of the affected limb.
Vibration and shape control of hinged light structures using electromagnetic forces
NASA Astrophysics Data System (ADS)
Matsuzaki, Yuji; Miyachi, Shigenobu; Sasaki, Toshiyuki
2003-08-01
This paper describes a new electromagnetic device for vibration control of a light-weighted deployable/retractable structure which consists of many small units connected with mechanical hinges. A typical example of such a structure is a solar cell paddle of an artificial satellite which is composed of many thin flexible blankets connected in series. Vibration and shape control of the paddle is not easy, because control force and energy do not transmit well between the blankets which are discretely connected by hinges with each other. The new device consists of a permanent magnet glued along an edge of a blanket and an electric current-conducting coil glued along an adjoining edge of another adjacent blanket. Conduction of the electric current in a magnetic field from the magnet generates an electromagnetic force on the coil. By changing the current in the coil, therefore, we may control the vibration and shape of the blankets. To confirm the effectiveness of the new device, constructing a simple paddle model consisting eight hinge- panels, we have carried out a model experiment of vibration and shape control of the paddle. In addition, a numerical simulation of vibration control of the hinge structure is performed to compare with measured data.
Huang, Yongqi; Gao, Meng; Su, Zhengding
2018-02-01
Three-dimensional (3D) domain swapping is a mechanism to form protein oligomers. It has been proposed that several factors, including proline residues in the hinge region, may affect the occurrence of 3D domain swapping. Although introducing prolines into the hinge region has been found to promote domain swapping for some proteins, the opposite effect has also been observed in several studies. So far, how proline affects 3D domain swapping remains elusive. In this work, based on a large set of 3D domain-swapped structures, we performed a systematic analysis to explore the correlation between the presence of proline in the hinge region and the occurrence of 3D domain swapping. We further analyzed the conformations of proline and pre-proline residues to investigate the roles of proline in 3D domain swapping. We found that more than 40% of the domain-swapped structures contained proline residues in the hinge region. Unexpectedly, conformational transitions of proline residues were rarely observed upon domain swapping. Our analyses showed that hinge regions containing proline residues preferred more extended conformations, which may be beneficial for the occurrence of domain swapping by facilitating opening of the exchanged segments.
Galván Duque-Gastélum, Carlos; Quiñones-Uriostegui, Ivett; Mendoza, Felipe; Rodríguez, Gerardo
2014-07-01
Ortheses are devices that assist in the function of the limbs, contributing with stability and support to the involved joints. KAFOs (knee-ankle-foot orthosis) are mainly indicated for people with muscular or neural diseases that affect the lower limbs. The actual designs of knee hinges for KAFOs compromise the stability and mobility of the limb. In this work, it was tested the feasibility of a design for a knee hinge for KAFO that should be able to modify its mechanical resistance depending on the gait phase. Orthotics biomechanical criteria and gait biomechanical requirements were considered. It was proposed an electromagnetic system in order to modify the hinge damping. In the future, the system will be interacting with a magnetorheological fluid (MR) which can change its rheological properties when a magnetic field is applied, thus, reaching different damping constants with the designed hinge. The diameter of the internal pipes required for the MR fluid to freely circulate within the orthosis was established. It was observed that the original design of the proposed orthotic hinge is feasible; however, some proposals are presented in order to achieve a better performance of the orthosis.
Adjustable hinge permits movement of knee in plaster cast
NASA Technical Reports Server (NTRS)
Maley, W. E.
1967-01-01
Metal knee hinge with an adjustable sleeve worn on the outside of a leg cast facilitates movement of the knee joint. This helps eliminate stiffness of the knee and eliminates bulkiness and adjustment difficulty.
Limitations of Lifting-Line Theory for Estimation of Aileron Hinge-Moment Characteristics
NASA Technical Reports Server (NTRS)
Swanson, Robert S.; Gillis, Clarence L.
1943-01-01
Hinge-moment parameters for several typical ailerons were calculated from section data with the aspect-ratio correction as usually determined from lifting-line theory. The calculations showed that the agreement between experimental and calculated results was unsatisfactory. An additional aspect-ratio correction, calculated by the method of lifting-surface theory, was applied to the slope of the curve of hinge-moment coefficient against angle of attack at small angles of attack. This so-called streamline-curvature correction brought the calculated and experimental results into satisfactory agreement.
NASA Technical Reports Server (NTRS)
Tang, M. H.; Pearson, G. P. E.
1973-01-01
Control-surface hinge-moment measurements obtained in the X-24A lifting body flight-test program are compared with results from wind-tunnel tests. The effects of variations in angle of attack, angle of sideslip, rudder bias, rudder deflection, upper-flap deflection, lower-flap deflection, Mach number, and rocket-engine operation on the control-surface hinge moments are presented. In-flight motion pictures of tufts attached to the inboard side of the right fin and the rudder and upper-flap surfaces are discussed.
Dynamic stability of a helicopter with hinged rotor blades
NASA Technical Reports Server (NTRS)
Hohenemser, K
1939-01-01
The present report is a study of the dynamic stability of a helicopter with hinged rotor blades under hovering conditions. While in this case perfect stability can in general not be obtained it is possible by means of design features to prolong the period of the spontaneous oscillations of the helicopter and reduce their amplification, and so approximately assure neutral equilibrium. The possibility of controlled stability of a helicopter fitted with hinged blades is proved by the successful flights of various helicopters, particularly of the Focker FW61 helicopter.
NASA Technical Reports Server (NTRS)
Hardin, R. B.; Burrows, R. R.
1975-01-01
A test is presented which was performed to determine the effect of cold jet gas plumes generated from main propulsion system and solid rocket motor nozzles on: (1) six-component force and moment data, (2) wing static pressures, (3) wing hinge moment, (4) elevon hinge moment, (5) rudder hinge moment, and (6) orbiter MPS nozzle pressure loads. The effects of rudder deflection, nozzle gimbal angle, and plume size were also obtained.
Subsonic wind-tunnel measurements of a slender wing-body configuration employing a vortex flap
NASA Technical Reports Server (NTRS)
Frink, Neal T.
1987-01-01
A wind tunnel study at Mach 0.4 was conducted for a slender wing-body configuration with a leading edge vortex flap of curved planform that is deflectable about a 74 degree swept hinge line. The basic data consist of a unique combination of longitudinal aerodynamic, surface pressure, and vortex flap hinge-moment measurements on a common model. The longitudinal aerodynamic, pressure and hinge-moment data are presented without analysis in tabular format. Plots of the tabulated pressure data are also given.
Means to flexibly attach lens frames to temple members
Smith, Harry D.
1995-01-01
The invention is a band hinge for flexibly connecting the temple member to the lens frame thereby preventing damage from inadvertent pressure or cyclic wear. A distinguishing feature of the invention is the use of a band hinge that holds together the temple member and the lens frame without the use of a pin or screw hinging mechanism. The invention allows for a high degree of freedom of movement for the temple member with respect to the lens frame which will prevent most forms of damages to the glasses from these types of events.
DESIGN: The Hershberger bioassay is designed to identify suspected androgens and antiandrogens based on changes in the weights of five androgen-responsive tissues (ventral prostate, paired seminal vesicles and coagulating glands, the levator ani and bulbocavernosus muscles, the g...
USDA-ARS?s Scientific Manuscript database
A cleft palate goat model was used to study the contractile properties of the levator veli palatini (LVP) muscle which is responsible for the movement of the soft palate. In 15-25% of patients that undergo palatoplasty, residual velopharyngeal insufficiency (VPI) remains a problem and often require...
Biomechanical Comparison of 3 Ankle Braces With and Without Free Rotation in the Sagittal Plane
Alfuth, Martin; Klein, Dieter; Koch, Raphael; Rosenbaum, Dieter
2014-01-01
Context: Various designs of braces including hinged and nonhinged models are used to provide external support of the ankle. Hinged ankle braces supposedly allow almost free dorsiflexion and plantar flexion of the foot in the sagittal plane. It is unclear, however, whether this additional degree of freedom affects the stabilizing effect of the brace in the other planes of motion. Objective: To investigate the dynamic and passive stabilizing effects of 3 ankle braces, 2 hinged models that provide free plantar flexion–dorsiflexion in the sagittal plane and 1 ankle brace without a hinge. Design: Crossover study. Setting: University Movement Analysis Laboratory. Patients or Other Participants: Seventeen healthy volunteers (5 women, 12 men; age = 25.4 ± 4.8 years; height = 180.3 ± 6.5 cm; body mass = 75.5 ± 10.4 kg). Intervention(s): We dynamically induced foot inversion on a tilting platform and passively induced foot movements in 6 directions via a custom-built apparatus in 3 brace conditions and a control condition (no brace). Main Outcome Measure(s): Maximum inversion was determined dynamically using an in-shoe electrogoniometer. Passively induced maximal joint angles were measured using a torque and angle sensor. We analyzed differences among the 4 ankle-brace conditions (3 braces, 1 control) for each of the dependent variables with Friedman and post hoc tests (P < .05). Results: Each ankle brace restricted dynamic foot-inversion movements on the tilting platform as compared with the control condition, whereas only the 2 hinged ankle braces differed from each other, with greater movement restriction caused by the Ankle X model. Passive foot inversion was reduced with all ankle braces. Passive plantar flexion was greater in the hinged models as compared with the nonhinged brace. Conclusions: All ankle braces showed stabilizing effects against dynamic and passive foot inversion. Differences between the hinged braces and the nonhinged brace did not appear to be clinically relevant. PMID:25098661
Campelo, Diana; Lautier, Thomas; Urban, Philippe; Esteves, Francisco; Bozonnet, Sophie; Truan, Gilles; Kranendonk, Michel
2017-01-01
NADPH-cytochrome P450 reductase (CPR) is a redox partner of microsomal cytochromes P450 and is a prototype of the diflavin reductase family. CPR contains 3 distinct functional domains: a FMN-binding domain (acceptor reduction), a linker (hinge), and a connecting/FAD domain (NADPH oxidation). It has been demonstrated that the mechanism of CPR exhibits an important step in which it switches from a compact, closed conformation (locked state) to an ensemble of open conformations (unlocked state), the latter enabling electron transfer to redox partners. The conformational equilibrium between the locked and unlocked states has been shown to be highly dependent on ionic strength, reinforcing the hypothesis of the presence of critical salt interactions at the interface between the FMN and connecting FAD domains. Here we show that specific residues of the hinge segment are important in the control of the conformational equilibrium of CPR. We constructed six single mutants and two double mutants of the human CPR, targeting residues G240, S243, I245 and R246 of the hinge segment, with the aim of modifying the flexibility or the potential ionic interactions of the hinge segment. We measured the reduction of cytochrome c at various salt concentrations of these 8 mutants, either in the soluble or membrane-bound form of human CPR. All mutants were found capable of reducing cytochrome c yet with different efficiency and their maximal rates of cytochrome c reduction were shifted to lower salt concentration. In particular, residue R246 seems to play a key role in a salt bridge network present at the interface of the hinge and the connecting domain. Interestingly, the effects of mutations, although similar, demonstrated specific differences when present in the soluble or membrane-bound context. Our results demonstrate that the electrostatic and flexibility properties of the hinge segment are critical for electron transfer from CPR to its redox partners. PMID:29163152
NASA Technical Reports Server (NTRS)
Wiley, Harleth G; Taylor, Robert T
1954-01-01
This paper present results of an investigation of the lateral-control and hinge-moment characteristics of a 0.67 semispan flap-type spoiler aileron on a semispan thin 60 degree delta wing at transonic speeds by the reflection-plane technique. The spoiler-aileron had a constant chord of 10.29 percent mean aerodynamic chord and was hinged at the 81.9-percent-wing-root-chord station. Tests were made with the spoiler aileron slot open, partially closed, and closed. Incremental rolling-moment coefficients were obtained through a Mach number range of 0.62 to 1.08. Results indicated reasonably linear variations of rolling-moment and hinge-moment coefficients with spoiler projection except at spoiler projections of less than -2 percent mean aerodynamic chord and angles of attack greater than 12 degrees with results generally independent of slot geometry.
Two-axis direct fluid shear stress sensor
NASA Technical Reports Server (NTRS)
Bajikar, Sateesh (Inventor); Scott, Michael A. (Inventor); Adcock, Edward E. (Inventor)
2011-01-01
A micro sized multi-axis semiconductor skin friction/wall shear stress induced by fluid flow. The sensor design includes a shear/strain transduction gimble connected to a force collecting plate located at the flow boundary surface. The shear force collecting plate is interconnected by an arm to offset the tortional hinges from the fluid flow. The arm is connected to the shear force collecting plate through dual axis torsional hinges with piezoresistive torsional strain gauges. These gauges are disposed on the tortional hinges and provide a voltage output indicative of applied shear stress acting on the force collection plate proximate the flow boundary surface. Offsetting the torsional hinges creates a force concentration and resolution structure that enables the generation of a large stress on the strain gauge from small shear stress, or small displacement of the collecting plate. The design also isolates the torsional sensors from exposure to the fluid flow.
[Sacrospinous colpopexy complications].
Estrade, J-P; Agostini, A; Roger, V; Dallay, D; Blanc, B; Cravello, L
2004-10-01
To evaluate complications of sacrospinous ligament fixation. Monocentric retrospective study. Department of Obstetrics & Gynecology, La Conception University Hospital, Marcella. Between January 1991 and September 2002, 277 women (mean age 64.9 years, range 37 to 92 years) underwent a sacrospinous ligament fixation; 91% had a menopausal status, and 15.5% used hormone replacement therapy. 33.2% of the patients had prior hysterectomy, 28.9% had a history of surgery for prolapse, and 18.8% had associated symptoms of stress urinary incontinence. In all cases, sacrospinous ligament fixation was performed under visual control using conventional stitch. Sacrospinous ligament fixation was combined with the following procedures: anterior vaginal repair (N =137), additional incontinence surgery (N =31), vaginal hysterectomy (N =137), levator myorraphy (N =203). Intraoperative complications, postoperative complications, long-term painful symptoms. Intraoperative complications were represented by 1 case of vascular wound and four rectal injuries. Main postoperative complications were vaginal haematomas (N =6) and abscesses (N =2). Long-term symptoms were perineal pain, sciatic neuralgia, and dyspareunia. There was no surgical mortality, and we noted low rates of major complications. Sacrospinous ligament fixation assumes high priority in our therapeutic regimen.
Enhanced multimaterial 4D printing with active hinges
NASA Astrophysics Data System (ADS)
Akbari, Saeed; Hosein Sakhaei, Amir; Kowsari, Kavin; Yang, Bill; Serjouei, Ahmad; Yuanfang, Zhang; Ge, Qi
2018-06-01
Despite great progress in four-dimensional (4D) printing, i.e. three-dimensional (3D) printing of active (stimuli-responsive) materials, the relatively low actuation force of the 4D printed structures often impedes their engineering applications. In this study, we use multimaterial inkjet 3D printing technology to fabricate shape memory structures, including a morphing wing flap and a deployable structure, which consist of active and flexible hinges joining rigid (non-active) parts. The active hinges, printed from a shape memory polymer (SMP), lock the structure into a second temporary shape during a thermomechanical programming process, while the flexible hinges, printed from an elastomer, effectively increase the actuation force and the load-bearing capacity of the printed structure as reflected in the recovery ratio. A broad range of mechanical properties such as modulus and failure strain can be achieved for both active and flexible hinges by varying the composition of the two base materials, i.e. the SMP and the elastomer, to accommodate large deformation induced during programming step, and enhance the recovery in the actuating step. To find the important design parameters, including local deformation, shape fixity and recovery ratio, we conduct high fidelity finite element simulations, which are able to accurately predict the nonlinear deformation of the printed structures. In addition, a coupled thermal-electrical finite element analysis was performed to model the heat transfer within the active hinges during the localized Joule heating process. The model predictions showed good agreement with the measured temperature data and were used to find the major parameters affecting temperature distribution including the applied voltage and the convection rate.
22. August 1974. BENCH SHOP, EAST WALL VIEW SHOWING HINGED ...
22. August 1974. BENCH SHOP, EAST WALL VIEW SHOWING HINGED PANEL AND WHEELPIT FOR MOUNTING SPOKES IN WHEEL HUB. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
Jang, Young Woong; Lim, DoHyung; Seo, Hansol; Lee, Myung Chul; Lee, O-Sung; Lee, Yong Seuk
2018-07-01
Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability. A finite element (FE) tibial model was combined with TomoFix plate, a LCfit plate with and without a metal block. Data analysis was conducted to evaluate the balanced stability, which refers to the enforced lateral stability resulting from redistribution of overall stress. We assessed the balanced stability of the medial implant and lateral hinge area in three cases using the same Sawbones and loads using the tibia FE model. The LCfit plate reduced stress by 23.1% at the lateral hinge compared to the TomoFix plate (TomoFix vs. LCfit: 34.2 ± 23.3 MPa vs. 26.3 ± 17.5 MPa). The LCfit plate with a metal block reduced stress by 40.1% at the medial plate (210.1 ± 64.2 MPa vs. 125.8 ± 65.7 MPa) and by 31.2% (26.3 ± 17.5 MPa vs. 18.1 ± 12.1 MPa) at the lateral hinge area compared to the reduction using the LCfit plate without a metal block. The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the healing of the medial cortex.
NASA Technical Reports Server (NTRS)
Rignot, Eric
1998-01-01
The synthetic-aperture radar interferometry technique is used to detect the migration of the limit of tidal flexing, or hinge line, of the floating ice tongue of Petermann Gletscher, a major outlet glacier of north Greenland.
14 CFR 25.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2010 CFR
2010-01-01
... designed for inertia loads acting parallel to the hinge line. (b) In the absence of more rational data, the inertia loads may be assumed to be equal to KW, where— (1) K=24 for vertical surfaces; (2) K=12 for...
14 CFR 25.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2012 CFR
2012-01-01
... designed for inertia loads acting parallel to the hinge line. (b) In the absence of more rational data, the inertia loads may be assumed to be equal to KW, where— (1) K=24 for vertical surfaces; (2) K=12 for...
14 CFR 25.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2011 CFR
2011-01-01
... designed for inertia loads acting parallel to the hinge line. (b) In the absence of more rational data, the inertia loads may be assumed to be equal to KW, where— (1) K=24 for vertical surfaces; (2) K=12 for...
14 CFR 25.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2014 CFR
2014-01-01
... designed for inertia loads acting parallel to the hinge line. (b) In the absence of more rational data, the inertia loads may be assumed to be equal to KW, where— (1) K=24 for vertical surfaces; (2) K=12 for...
14 CFR 25.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2013 CFR
2013-01-01
... designed for inertia loads acting parallel to the hinge line. (b) In the absence of more rational data, the inertia loads may be assumed to be equal to KW, where— (1) K=24 for vertical surfaces; (2) K=12 for...
Mechanics Model for Simulating RC Hinges under Reversed Cyclic Loading
Shukri, Ahmad Azim; Visintin, Phillip; Oehlers, Deric J.; Jumaat, Mohd Zamin
2016-01-01
Describing the moment rotation (M/θ) behavior of reinforced concrete (RC) hinges is essential in predicting the behavior of RC structures under severe loadings, such as under cyclic earthquake motions and blast loading. The behavior of RC hinges is defined by localized slip or partial interaction (PI) behaviors in both the tension and compression region. In the tension region, slip between the reinforcement and the concrete defines crack spacing, crack opening and closing, and tension stiffening. While in the compression region, slip along concrete to concrete interfaces defines the formation and failure of concrete softening wedges. Being strain-based, commonly-applied analysis techniques, such as the moment curvature approach, cannot directly simulate these PI behaviors because they are localized and displacement based. Therefore, strain-based approaches must resort to empirical factors to define behaviors, such as tension stiffening and concrete softening hinge lengths. In this paper, a displacement-based segmental moment rotation approach, which directly simulates the partial interaction behaviors in both compression and tension, is developed for predicting the M/θ response of an RC beam hinge under cyclic loading. Significantly, in order to develop the segmental approach, a partial interaction model to predict the tension stiffening load slip relationship between the reinforcement and the concrete is developed. PMID:28773430
Mechanics Model for Simulating RC Hinges under Reversed Cyclic Loading.
Shukri, Ahmad Azim; Visintin, Phillip; Oehlers, Deric J; Jumaat, Mohd Zamin
2016-04-22
Describing the moment rotation (M/θ) behavior of reinforced concrete (RC) hinges is essential in predicting the behavior of RC structures under severe loadings, such as under cyclic earthquake motions and blast loading. The behavior of RC hinges is defined by localized slip or partial interaction (PI) behaviors in both the tension and compression region. In the tension region, slip between the reinforcement and the concrete defines crack spacing, crack opening and closing, and tension stiffening. While in the compression region, slip along concrete to concrete interfaces defines the formation and failure of concrete softening wedges. Being strain-based, commonly-applied analysis techniques, such as the moment curvature approach, cannot directly simulate these PI behaviors because they are localized and displacement based. Therefore, strain-based approaches must resort to empirical factors to define behaviors, such as tension stiffening and concrete softening hinge lengths. In this paper, a displacement-based segmental moment rotation approach, which directly simulates the partial interaction behaviors in both compression and tension, is developed for predicting the M/θ response of an RC beam hinge under cyclic loading. Significantly, in order to develop the segmental approach, a partial interaction model to predict the tension stiffening load slip relationship between the reinforcement and the concrete is developed.
Shock Location Dominated Transonic Flight Loads on the Active Aeroelastic Wing
NASA Technical Reports Server (NTRS)
Lokos, William A.; Lizotte, Andrew; Lindsley, Ned J.; Stauf, Rick
2005-01-01
During several Active Aeroelastic Wing research flights, the shadow of the over-wing shock could be observed because of natural lighting conditions. As the plane accelerated, the shock location moved aft, and as the shadow passed the aileron and trailing-edge flap hinge lines, their associated hinge moments were substantially affected. The observation of the dominant effect of shock location on aft control surface hinge moments led to this investigation. This report investigates the effect of over-wing shock location on wing loads through flight-measured data and analytical predictions. Wing-root and wing-fold bending moment and torque and leading- and trailing-edge hinge moments have been measured in flight using calibrated strain gages. These same loads have been predicted using a computational fluid dynamics code called the Euler Navier-Stokes Three Dimensional Aeroelastic Code. The computational fluid dynamics study was based on the elastically deformed shape estimated by a twist model, which in turn was derived from in-flight-measured wing deflections provided by a flight deflection measurement system. During level transonic flight, the shock location dominated the wing trailing-edge control surface hinge moments. The computational fluid dynamics analysis based on the shape provided by the flight deflection measurement system produced very similar results and substantially correlated with the measured loads data.
Visualizing Key Hinges and a Potential Major Source of Compliance in the Lever Arm of Myosin
DOE Office of Scientific and Technical Information (OSTI.GOV)
J Brown; V Senthil Kumar; E ONeall-Hennessey
2011-12-31
We have determined the 2.3-{angstrom}-resolution crystal structure of a myosin light chain domain, corresponding to one type found in sea scallop catch ('smooth') muscle. This structure reveals hinges that may function in the 'on' and 'off' states of myosin. The molecule adopts two different conformations about the heavy chain 'hook' and regulatory light chain (RLC) helix D. This conformational change results in extended and compressed forms of the lever arm whose lengths differ by 10 {angstrom}. The heavy chain hook and RLC helix D hinges could thus serve as a potential major and localized source of cross-bridge compliance during themore » contractile cycle. In addition, in one of the molecules of the crystal, part of the RLC N-terminal extension is seen in atomic detail and forms a one-turn alpha-helix that interacts with RLC helix D. This extension, whose sequence is highly variable in different myosins, may thus modulate the flexibility of the lever arm. Moreover, the relative proximity of the phosphorylation site to the helix D hinge suggests a potential role for conformational changes about this hinge in the transition between the on and off states of regulated myosins.« less
Visualizing key hinges and a potential major source of compliance in the lever arm of myosin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, J.H.; Robinson, H.; Senthil Kumar, V. S.
2011-01-04
We have determined the 2.3-{angstrom}-resolution crystal structure of a myosin light chain domain, corresponding to one type found in sea scallop catch ('smooth') muscle. This structure reveals hinges that may function in the 'on' and 'off' states of myosin. The molecule adopts two different conformations about the heavy chain 'hook' and regulatory light chain (RLC) helix D. This conformational change results in extended and compressed forms of the lever arm whose lengths differ by 10 {angstrom}. The heavy chain hook and RLC helix D hinges could thus serve as a potential major and localized source of cross-bridge compliance during themore » contractile cycle. In addition, in one of the molecules of the crystal, part of the RLC N-terminal extension is seen in atomic detail and forms a one-turn alpha-helix that interacts with RLC helix D. This extension, whose sequence is highly variable in different myosins, may thus modulate the flexibility of the lever arm. Moreover, the relative proximity of the phosphorylation site to the helix D hinge suggests a potential role for conformational changes about this hinge in the transition between the on and off states of regulated myosins.« less
Yin, Ningbei; Wu, Jiajun; Chen, Bo; Song, Tao; Ma, Hengyuan; Zhao, Zhenmin; Wang, Yongqian; Li, Haidong; Wu, Di
2015-03-01
Plastic surgeons have attempted various ways to rebuild the aesthetic subunits of the upper lip in patients with cleft lip with less than perfect results in most cases. We propose that repairing the 3 muscle tension line groups in the nasolabial complex will have improved aesthetic results. Micro-computed tomographic scans were performed on the nasolabial tissues of 5 normal aborted fetuses and used to construct a 3-dimensional model to study the nasolabial muscle complex structure. The micro-computed tomographic (CT) scans showed the close relationship and interaction between the muscle fibers of nasalis, pars peripheralis, levator labii superioris, and pars marginalis. Based on the 2-dimensional images obtained from the micro-computed tomographic scans, we suggest the concept of nasolabial muscle complex and muscle tension line group theory: there is a close relationship among the alar part of the nasalis, depressor septi muscle, orbicularis oris muscle, and levator labii superioris alaeque nasi. The tension line groups are 3 tension line structures in the nasolabial muscle complex that interlock with each other at the intersections and maintain the specific shape and aesthetics of the lip and nose.
Surgical anatomy of the prostate in the era of radical robotic prostatectomy.
Walz, Jochen; Graefen, Markus; Huland, Hartwig
2011-05-01
New insights in the anatomy of the prostate and the surrounding tissue evolve the technique of radical prostatectomy for the treatment of prostate cancer. Regarding the course of the erectile nerves along the prostate, recent studies confirmed the presence of parasympathetic pro-erectile nerve fibers at the anterolateral aspect of the prostate. Another study of intraoperative electrostimulation of those nerves confirmed an increase in intracavernosal pressure by stimulations between the 1 and 3 o'clock position. Therefore, it is very likely that these anterior nerve fibers have an effect on erectile function. Regarding the urethral sphincter in the male, a study showed no attachment of the external sphincter to the levator ani muscle, probably resulting in an absence of a levator ani support to the continence mechanism. The male urinary sphincter seems to be in isolation responsible for urinary continence. The nerve fibers at the anterolateral aspect of the prostate seem to participate in erectile function, which renders the concept of a high anterior release during nerve sparing beneficial. The isolated urinary sphincter mechanism results in the need to conserve as much urethral length as possible during radical prostatectomy to avoid urinary incontinence.
[Physiology of the urethral sphincteric vesico-prostatic complex].
Carmignani, L; Gadda, F; Dell'Orto, P; Ferruti, M; Grisotto, M; Rocco, F
2001-09-01
We propose a review of the literature about innervation and physiology of the urethral sphincteric complex. Parasympathetic innervation of the pelvic viscera comes from ventral branches of the sacral nerves (S2-S4). The orthosympathetic component derives from superior hypogastric plexus and runs down the hypogastric nerves to form the right and left pelvic plexus together with the parasympathetic component. The pelvic plexus is situated inferolaterally with respect to the rectum and runs on the surface of the levator ani muscle down to the prostatic apex. The pelvic plexus gives innervation to the rectum, the bladder, the prostate and the urethral sphincteric complex. The pelvic muscular floor is innervated by the somatic component (pudendal nerve) derived from the sacral branches (S2-S4). Bladder neck and smooth muscle urethral sphincter innervation is given mostly by the orthosympathetic component. The rhabdosphincter innervation comes from the pudendal nerve and from the pelvic plexus; its role in the continence mechanism is probably to give steady tonic urethral compression. Levator ani muscle takes part in the sphincteric complex with its anteromedial pubococcygeal portion. It plays its role strengthening the sphincteric tone during increase of the abdominal pressure or during active quick stop cessation of the urinary stream.
Watier, Alain; Rigaud, Jérôme; Labat, Jean-Jacques
2010-11-01
To define functional gastrointestinal pain, irritable bowel syndrome (IBS), levator ani syndrome, proctalgia fugax, the pathophysiology of these syndromes and the treatments that can be proposed. Review of articles published on the theme based on a Medline (PubMed) search and consensus conferences selected according to their scientific relevance. IBS is very common. Patients report abdominal pain and/or discomfort, bloating, and abnormal bowel habit (diarrhoea, constipation or both), in the absence of any structural or biochemical abnormalities. IBS has a complex, multifactorial pathophysiology, involving biological and psychosocial interactions resulting in dysregulation of the brain-gut axis associated with disorders of intestinal motility, hyperalgesia, immune disorders and disorders of the intestinal bacterial microflora and autonomic and hormonal dysfunction. Many treatments have been proposed, ranging from diet to pharmacology and psychotherapy. Patients with various types of chronic pelvic and perineal pain, especially those seen in urology departments, very often report associated IBS. This syndrome is also part of a global and integrated concept of pelviperineal dysfunction, avoiding a rigorous distinction between the posterior segment and the midline and anterior segments of the perineum. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Belle II SVD ladder assembly procedure and electrical qualification
NASA Astrophysics Data System (ADS)
Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, Varghese; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, T.; Basith, A. K.; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Casarosa, G.; Ceccanti, M.; Červenkov, D.; Chendvankar, S. R.; Dash, N.; Divekar, S. T.; Doležal, Z.; Dutta, D.; Forti, F.; Friedl, M.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C.; Kandra, J.; Kang, K. H.; Kato, E.; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M.; Kvasnička, P.; Lanceri, L.; Lettenbicher, J.; Mammini, P.; Mayekar, S. N.; Mohanty, G. B.; Mohanty, S.; Morii, T.; Nakamura, K. R.; Natkaniec, Z.; Negishi, K.; Nisar, N. K.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rao, K. K.; Rashevskaya, I.; Rizzo, G.; Rozanska, M.; Sandilya, S.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Tanaka, S.; Tanida, K.; Taylor, G. N.; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Vitale, L.; Volpi, M.; Watanuki, S.; Watson, I. J.; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.; Belle II SVD Collaboration
2016-07-01
The Belle II experiment at the SuperKEKB asymmetric e+e- collider in Japan will operate at a luminosity approximately 50 times larger than its predecessor (Belle). At its heart lies a six-layer vertex detector comprising two layers of pixelated silicon detectors (PXD) and four layers of double-sided silicon microstrip detectors (SVD). One of the key measurements for Belle II is time-dependent CP violation asymmetry, which hinges on a precise charged-track vertex determination. Towards this goal, a proper assembly of the SVD components with precise alignment ought to be performed and the geometrical tolerances should be checked to fall within the design limits. We present an overview of the assembly procedure that is being followed, which includes the precision gluing of the SVD module components, wire-bonding of the various electrical components, and precision three dimensional coordinate measurements of the jigs used in assembly as well as of the final SVD modules.
Ankle Distraction Arthroplasty: Indications, Technique, and Outcomes.
Bernstein, Mitchell; Reidler, Jay; Fragomen, Austin; Rozbruch, S Robert
2017-02-01
Ankle distraction is an alternative to ankle arthrodesis or total ankle arthroplasty in younger patients with arthritis. Ankle distraction involves the use of external fixation to mechanically unload the ankle joint, which allows for stable, congruent range of motion in the setting of decreased mechanical loading, potentially promoting cartilage repair. Adjunct surgical procedures are frequently done to address lower-extremity malalignment, ankle equinus contractures, and impinging tibiotalar osteophytes. Patients can bear full weight during the treatment course. The distraction frame frequently uses a hinge, and patients are encouraged to do daily range-of-motion exercises. Although the initial goal of the procedure is to delay arthrodesis, many patients achieve lasting clinical benefits, obviating the need for total ankle arthroplasty or fusion. Complications associated with external fixation are common, and patients should be counseled that clinical improvements occur slowly and often are not achieved until at least 1 year after frame removal.
A New Germfree Chicken Cage—Characteristics and Use1
Miller, Herman T.; Luckey, T. D.
1962-01-01
A new germfree chicken cage for rearing chicks up to 3 or 4 weeks of age has been designed and is in use at the University of Missouri. The cage and the accessory parts, the small magnet and hinged door, the “Bactytector,” the built-in air filter assembly, and the glass top with connecting air outlet filter have been described in detail. The complete operating procedure for sterilizing the cage and diet and the method of adding sterile embryonated eggs have been outlined. Data on the effectiveness of the cage as a physical barrier to microbes have been presented. Images FIG. 1 FIG. 3 PMID:14474027
28. BRIDGE NO. 9 APRON AND BRIDGE HINGE JOINT AND ...
28. BRIDGE NO. 9 APRON AND BRIDGE HINGE JOINT AND BRIDGE SUSPENSION SYSTEM SHOWING EYEBAR AND CABLE CONNECTIONS. LOOKING WEST. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ
DETAIL OF ORIGINAL SLIDING DOORS ALTERED WITH OPENING FOR HINGED ...
DETAIL OF ORIGINAL SLIDING DOORS ALTERED WITH OPENING FOR HINGED DOOR. WITH GRADUATED SCALE IN 1' INCREMENTS. VIEW FACING NORTHWEST - U.S. Naval Base, Pearl Harbor, Gymnasium Building, North Waterfront & Pierce Street near Berth S-13, Pearl City, Honolulu County, HI
Non-equivalent role of TM2 gating hinges in heteromeric Kir4.1/Kir5.1 potassium channels
Shang, Lijun
2007-01-01
Comparison of the crystal structures of the KcsA and MthK potassium channels suggests that the process of opening a K+ channel involves pivoted bending of the inner pore-lining helices at a highly conserved glycine residue. This bending motion is proposed to splay the transmembrane domains outwards to widen the gate at the “helix-bundle crossing”. However, in the inwardly rectifying (Kir) potassium channel family, the role of this “hinge” residue in the second transmembrane domain (TM2) and that of another putative glycine gating hinge at the base of TM2 remain controversial. We investigated the role of these two positions in heteromeric Kir4.1/Kir5.1 channels, which are unique amongst Kir channels in that both subunits lack a conserved glycine at the upper hinge position. Contrary to the effect seen in other channels, increasing the potential flexibility of TM2 by glycine substitutions at the upper hinge position decreases channel opening. Furthermore, the contribution of the Kir4.1 subunit to this process is dominant compared to Kir5.1, demonstrating a non-equivalent contribution of these two subunits to the gating process. A homology model of heteromeric Kir4.1/Kir5.1 shows that these upper “hinge” residues are in close contact with the base of the pore α-helix that supports the selectivity filter. Our results also indicate that the highly conserved glycine at the “lower” gating hinge position is required for tight packing of the TM2 helices at the helix-bundle crossing, rather than acting as a hinge residue. PMID:17657484
The effects of klapskate hinge position on push-off performance: a simulation study.
Houdijk, Han; Bobbert, Maarten F; De Koning, Jos J; De Groot, Gert
2003-12-01
The introduction of the klapskate in speed skating confronts skaters with the question of how to adjust the position of the hinge in order to maximize performance. The purpose of this study was to reveal the constraint that klapskate hinge position imposes on push-off performance in speed skating. For this purpose, a model of the musculoskeletal system was designed to simulate a simplified, two-dimensional skating push off. To capture the essence of a skating push off, this model performed a one-leg vertical jump, from a frictionless surface, while keeping its trunk horizontally. In this model, klapskate hinge position was varied by varying the length of the foot segment between 115 and 300 mm. With each foot length, an optimal control solution was found that resulted in the maximal amount of vertical kinetic and potential energy of the body's center of mass at take off (Weff). Foot length was shown to considerably affect push-off performance. Maximal Weff was obtained with a foot length of 185 mm and decreased by approximately 25% at either foot length of 115 mm and 300 mm. The reason for this decrease was that foot length affected the onset and control of foot rotation. This resulted in a distortion of the pattern of leg segment rotations and affected muscle work (Wmus) and the efficacy ratio (Weff/Wmus) of the entire leg system. Despite its simplicity, the model very well described and explained the effects of klapskate hinge position on push off performance that have been observed in speed-skating experiments. The simplicity of the model, however, does not allow quantitative analyses of optimal klapskate hinge position for speed-skating practice.
Experimental and Numerical Assessment of a New Alternative of RBS Moment Connection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mirghaderi, Rasoul; Imanpour, Ali; Keshavarzi, Farhad
2008-07-08
Reduced beam section (RBS) connection has been known as a famous connection for steel moment-resisting seismic frames in high-rise buildings, because of their economical advantages and seismic ductility. In the ordinary RBS connection, often portions of the beam flanges are selectively trimmed in the region adjacent to the beam-to-column connection, and beam section is weakened in the plastic hinge region; section weakening concept in the plastic hinge region of beam cause to reduction of beam plastic section modulus in this region, and force plastic hinge to occur within the reduced section.This paper presents a new alternative of RBS connection thatmore » has been used aforesaid weakening concept in it, with this difference that corrugated steel plate webs instead of beam flange cutting has been used in limited specific length near the column face. Corrugated steel plates because of their accordion effect don't have bending rigidity, then using of these plates in plastic hinge region reduces the beam plastic section modulus and plastic hinge is formed in corrugated region. For investigating the seismic behavior and performance of new RBS moment connection, experimental specimen of new RBS connection were subjected to cyclic load, and finite element analysis were executed. The result of cyclic test and numerical analysis specified that the corrugated webs improved the plastic stability and provided capability of large plastic rotation at the plastic hinge location without any appreciable buckling and brittle fractures in this region. The test observations also showed that the specimens' plastic rotations exceeded 0.04 rad without any local and global buckling. All of the analytical results for proposed connection are generally in good agreement with the test observations.« less
Interconversion of Functional Motions between Mesophilic and Thermophilic Adenylate Kinases
Daily, Michael D.; Phillips, George N.; Cui, Qiang
2011-01-01
Dynamic properties are functionally important in many proteins, including the enzyme adenylate kinase (AK), for which the open/closed transition limits the rate of catalytic turnover. Here, we compare our previously published coarse-grained (double-well Gō) simulation of mesophilic AK from E. coli (AKmeso) to simulations of thermophilic AK from Aquifex aeolicus (AKthermo). In AKthermo, as with AKmeso, the LID domain prefers to close before the NMP domain in the presence of ligand, but LID rigid-body flexibility in the open (O) ensemble decreases significantly. Backbone foldedness in O and/or transition state (TS) ensembles increases significantly relative to AKmeso in some interdomain backbone hinges and within LID. In contact space, the TS of AKthermo has fewer contacts at the CORE-LID interface but a stronger contact network surrounding the CORE-NMP interface than the TS of AKmeso. A “heated” simulation of AKthermo at 375K slightly increases LID rigid-body flexibility in accordance with the “corresponding states” hypothesis. Furthermore, while computational mutation of 7 prolines in AKthermo to their AKmeso counterparts produces similar small perturbations, mutation of these sites, especially positions 8 and 155, to glycine is required to achieve LID rigid-body flexibility and hinge flexibilities comparable to AKmeso. Mutating the 7 sites to proline in AKmeso reduces some hinges' flexibilities, especially hinge 2, but does not reduce LID rigid-body flexibility, suggesting that these two types of motion are decoupled in AKmeso. In conclusion, our results suggest that hinge flexibility and global functional motions alike are correlated with but not exclusively determined by the hinge residues. This mutational framework can inform the rational design of functionally important flexibility and allostery in other proteins toward engineering novel biochemical pathways. PMID:21779157
Hinge residue I174 is critical for proper dNTP selection by DNA polymerase beta.
Yamtich, Jen; Starcevic, Daniela; Lauper, Julia; Smith, Elenoe; Shi, Idina; Rangarajan, Sneha; Jaeger, Joachim; Sweasy, Joann B
2010-03-23
DNA polymerase beta (pol beta) is the key gap-filling polymerase in base excision repair, the DNA repair pathway responsible for repairing up to 20000 endogenous lesions per cell per day. Pol beta is also widely used as a model polymerase for structure and function studies, and several structural regions have been identified as being critical for the fidelity of the enzyme. One of these regions is the hydrophobic hinge, a network of hydrophobic residues located between the palm and fingers subdomains. Previous work by our lab has shown that hinge residues Y265, I260, and F272 are critical for polymerase fidelity by functioning in discrimination of the correct from incorrect dNTP during ground state binding. Our work aimed to elucidate the role of hinge residue I174 in polymerase fidelity. To study this residue, we conducted a genetic screen to identify mutants with a substitution at residue I174 that resulted in a mutator polymerase. We then chose the mutator mutant I174S for further study and found that it follows the same general kinetic pathway as and has an overall protein folding similar to that of wild-type (WT) pol beta. Using single-turnover kinetic analysis, we found that I174S exhibits decreased fidelity when inserting a nucleotide opposite a template base G, and this loss of fidelity is due primarily to a loss of discrimination during ground state dNTP binding. Molecular dynamics simulations show that mutation of residue I174 to serine results in an overall tightening of the hinge region, resulting in aberrant protein dynamics and fidelity. These results point to the hinge region as being critical in the maintenance of the proper geometry of the dNTP binding pocket.
PLAN2D - A PROGRAM FOR ELASTO-PLASTIC ANALYSIS OF PLANAR FRAMES
NASA Technical Reports Server (NTRS)
Lawrence, C.
1994-01-01
PLAN2D is a FORTRAN computer program for the plastic analysis of planar rigid frame structures. Given a structure and loading pattern as input, PLAN2D calculates the ultimate load that the structure can sustain before collapse. Element moments and plastic hinge rotations are calculated for the ultimate load. The location of hinges required for a collapse mechanism to form are also determined. The program proceeds in an iterative series of linear elastic analyses. After each iteration the resulting elastic moments in each member are compared to the reserve plastic moment capacity of that member. The member or members that have moments closest to their reserve capacity will determine the minimum load factor and the site where the next hinge is to be inserted. Next, hinges are inserted and the structural stiffness matrix is reformulated. This cycle is repeated until the structure becomes unstable. At this point the ultimate collapse load is calculated by accumulating the minimum load factor from each previous iteration and multiplying them by the original input loads. PLAN2D is based on the program STAN, originally written by Dr. E.L. Wilson at U.C. Berkeley. PLAN2D has several limitations: 1) Although PLAN2D will detect unloading of hinges it does not contain the capability to remove hinges; 2) PLAN2D does not allow the user to input different positive and negative moment capacities and 3) PLAN2D does not consider the interaction between axial and plastic moment capacity. Axial yielding and buckling is ignored as is the reduction in moment capacity due to axial load. PLAN2D is written in FORTRAN and is machine independent. It has been tested on an IBM PC and a DEC MicroVAX. The program was developed in 1988.
[ANALYSIS OF IMPLANT-RELATED COMPLICATIONS AFTER HINGE KNEE REPLACEMENT FOR TUMORS AROUND THE KNEE].
Li, Dong; Ma, Huanzhi; Zhang, Wei; Sun, Chengliang; Lu, Xiaoyong; Gao, Yutong; Zhou, Dongsheng
2015-08-01
To investigate the reasons and managements of implant-related complications after hinge knee replacement for tumors around the knee. A retrospective analysis was made on the clinical data of 96 patients undergoing hinge knee replacement between January 2000 and December 2012. There were 64 males and 32 females with the mean age of 31.0 years (range, 15-72 years). The most common tumor type was osteosarcoma (72 cases), and the second was giant cell tumor (15 cases). The tumor located at the distal femurs in 52 cases and at the proximal tibias in 44 cases. Fifteen hinge and 81 rotating hinge prostheses were used. The recurrence, metastasis, and survival were recorded. The implant-related complications were observed. The median follow-up time was 43.5 months (range, 10-156 months). Complications were observed in 21 patients (25 implant-related complications); 13 complications located at the femur and 12 complications at the tibia. The complications included aseptic loosening (8 cases), deep infection (7 cases), prosthetic breakage (4 cases), peri-prosthetic fracture (2 cases), and dislocation (4 cases). Most deep infection occurred within 12 months after operation (6/7), and most aseptic loosening after 40 months of operation (6/8). The rate of limb salvage was 90.6% (87/96) and the amputation rate was 9.4% (9/96). The overall survival rate of the prosthesis was 76.7% (5-year) and 47.2% (10-year). The 5-year survival rate was 82.9% for femoral prosthesis and 71.0% for tibial prosthesis, showing no significant difference (P = 0.954). Hinge knee prosthesis still has a high rate of complications. Deep infection is main reason to decrease short-term prosthetic survival rate, and aseptic loosening shortens the long-short prosthetic survival time.
29. BRIDGE NO. 13 APRON AND BRIDGE HINGE JOINT AND ...
29. BRIDGE NO. 13 APRON AND BRIDGE HINGE JOINT AND BRIDGE SUSPENSION SYSTEM (OLDER STYLE) SHOWING EYEBAR AND CABLE CONNECTIONS. LOOKING WEST. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ
10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... transparent or solid doors, sliding or hinged doors, a combination of hinged, sliding, transparent, or solid... compressors, refrigerant condensers, condenser fans and motors, and factory supplied accessories. Self... more refrigerant compressors, refrigerant condensers, condenser fans and motors, and factory supplied...
Modal identities for multibody elastic spacecraft: An aid to selecting modes for simulation
NASA Technical Reports Server (NTRS)
Hablani, Hari B.
1989-01-01
The question: Which set of modes furnishes a higher fidelity math model of dynamics of a multibody, deformable spacecraft (hinges-free or hinges-locked vehicle modes) is answered. Two sets of general, discretized, linear equations of motion of a spacecraft with an arbitrary number of deformable appendages, each articulated directly to the core body, are obtained using the above two families of modes. By a comparison of these equations, ten sets of modal identities are constructed which involve modal momenta coefficients and frequencies associated with both classes of modes. The sums of infinite series that appear in the identities are obtained in terms of mass, and first and second moments of inertia of the appendages, core body, and vehicle by using certain basic identities concerning appendage modes. Applying the above identities to a four-body spacecraft, the hinges-locked vehicle modes are found to yield a higher fidelity model than hinges-free modes, because the latter modes have nonconverging modal coefficients; a characteristic proved and illustrated.
Purohit, Prasad
2011-01-01
The extent to which agonists activate synaptic receptor-channels depends on both the intrinsic tendency of the unliganded receptor to open and the amount of agonist binding energy realized in the channel-opening process. We examined mutations of the nicotinic acetylcholine receptor transmitter binding site (α subunit loop B) with regard to both of these parameters. αGly147 is an “activation” hinge where backbone flexibility maintains high values for intrinsic gating, the affinity of the resting conformation for agonists and net ligand binding energy. αGly153 is a “deactivation” hinge that maintains low values for these parameters. αTrp149 (between these two glycines) serves mainly to provide ligand binding energy for gating. We propose that a concerted motion of the two glycine hinges (plus other structural elements at the binding site) positions αTrp149 so that it provides physiologically optimal binding and gating function at the nerve-muscle synapse. PMID:21115636
Collective Dynamics of Periplasmic Glutamine Binding Protein upon Domain Closure
Loeffler, Hannes H.; Kitao, Akio
2009-01-01
The glutamine binding protein is a vital component of the associated ATP binding cassette transport systems responsible for the uptake of glutamine into the cell. We have investigated the global movements of this protein by molecular dynamics simulations and principal component analysis (PCA). We confirm that the most dominant mode corresponds to the biological function of the protein, i.e., a hinge-type motion upon ligand binding. The closure itself was directly observed from two independent trajectories whereby PCA was used to elucidate the nature of this closing reaction. Two intermediary states are identified and described in detail. The ligand binding induces the structural change of the hinge regions from a discontinuous β-sheet to a continuous one, which also enhances softness of the hinge and modifies the direction of hinge motion to enable closing. We also investigated the convergence behavior of PCA modes, which were found to converge rather quickly when the associated magnitudes of the eigenvalues are well separated. PMID:19883597
Ultra-precise micro-motion stage for optical scanning test
NASA Astrophysics Data System (ADS)
Chen, Wen; Zhang, Jianhuan; Jiang, Nan
2009-05-01
This study aims at the application of optical sensing technology in a 2D flexible hinge test stage. Optical fiber sensor which is manufactured taking advantage of the various unique properties of optical fiber, such as good electric insulation properties, resistance of electromagnetic disturbance, sparkless property and availability in flammable and explosive environment, has lots of good properties, such as high accuracy and wide dynamic range, repeatable, etc. and is applied in 2D flexible hinge stage driven by PZT. Several micro-bending structures are designed utilizing the characteristics of the flexible hinge stage. And through experiments, the optimal micro-bending tooth structure and the scope of displacement sensor trip under this optimal micro-bending tooth structure are derived. These experiments demonstrate that the application of optical fiber displacement sensor in 2D flexible hinge stage driven by PZT substantially broadens the dynamic testing range and improves the sensitivity of this apparatus. Driving accuracy and positioning stability are enhanced as well. [1,2
Thibault-Gagnon, Stéphanie; Goldfinger, Corrie; Pukall, Caroline; Chamberlain, Susan; McLean, Linda
2018-03-01
Digital intravaginal palpation remains the favored method for clinical assessment of pelvic floor muscle (PFM) function in women; however, there is growing interest in using transperineal ultrasound imaging (TPUSI). TPUSI does not involve vaginal penetration, making it particularly relevant for PFM assessment in women with genito-pelvic pain and penetration disorders. To study the relations between measures of PFM morphology and function assessed using 3-dimensional (3D) TPUSI and PFM assessment through intravaginal palpation. 77 nulliparous premenopausal women with (n = 38) and without (n = 39) PVD participated. 3D TPUSI was used to measure levator hiatal dimensions at rest, at maximal voluntary contraction (MVC) of the PFMs, and at maximal Valsalva maneuver (MVM). Intravaginal palpation was used to assess PFM strength, PFM tone, PFM relaxation after contraction, and vaginal flexibility; each was scored using an ordinal grading scale. Ultrasound and palpation outcomes were compared using Spearman correlation coefficients and Kruskal-Wallis 1-way analyses of variance by rank. Outcomes included ultrasound measures of the levator hiatal area, anteroposterior diameter, and left-right transverse diameter at rest, at MVC, and at MVM; raw and relative changes in hiatal dimensions between rest and MVC and between rest and MVM; and palpation measures of PFM strength, tone, and relaxation after contraction, and vaginal flexibility. Weak to fair correlations were found between ultrasound and palpation measures. A smaller levator hiatus at rest was associated with greater PFM tone, less PFM relaxation, and less vaginal flexibility. Greater levator hiatal constriction and shortening of the hiatal anteroposterior diameter at MVC were associated with greater palpated PFM strength. Greater hiatal distention at MVM was associated with lower PFM tone and greater relaxation. 3D TPUSI and intravaginal palpation provide related but distinct information about PFM function in young women with and without PVD with high functioning PFMs. This was the first study to compare PFM assessment using 3D TPUSI and intravaginal palpation in nulliparous premenopausal women. A main strength of the study was the inclusion of women with PVD and asymptomatic controls, which provided a wide range in outcomes because differences in PFM morphology and function exist between women with and without PVD. The lack of inclusion of older women and women with weaker and/or hypotonic PFMs limits the generalizability of the findings. Although TPUSI has several advantages, including painless application, it is not recommended as a replacement for digital palpation in the clinical assessment of PFM function. Thibault-Gagnon S, Goldfinger C, Pukall C, et al. Relationships Between 3-Dimensional Transperineal Ultrasound Imaging and Digital Intravaginal Palpation Assessments of the Pelvic Floor Muscles in Women With and Without Provoked Vestibulodynia. J Sex Med 2018;15:346-360. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.
Subduction hinge migration: The backwards component of plate tectonics
NASA Astrophysics Data System (ADS)
Stegman, D.; Freeman, J.; Schellart, W.; Moresi, L.; May, D.
2005-12-01
There are approximately 50 distinct segments of subduction zones in the world, of which 40% have oceanic lithosphere subducting under oceanic lithosphere. All of these ocean-ocean systems are currently experiencing hinge-rollback, with the exception of 2 (Mariana and Kermadec). In hinge-rollback, the surface trace of the suduction zone (trench) is moving in the opposite direction as the plate is moving (i.e. backwards). Coincidentally, the fastest moving plate boundary in the world is actually the Tonga trench at an estimated 17 cm/yr (backwards). Although this quite important process was recognized soon after the birth of plate tectonic theory (Elsasser, 1971), it has received only a limited amount of attention (Garfunkel, 1986; Kincaid and Olson, 1987) until recently. Laboratory models have shown that having a three dimensional experiment is essential in order to build a correct understanding of subduction. We have developed a numerical model with the neccessary 3-D geometry capable of investigating some fundamental questions of plate tectonics: How does hinge-rollback feedback into surface tectonics and mantle flow? What can we learn about the forces that drive plate tectonics by studying hinge-rollback? We will present a quantatitive analysis of the effect of the lateral width of subduction zones, the key aspect to understanding the nature of hinge-rollback. Additionally, particular emphasis has been put on gaining intuition through the use of movies (a 3-D rendering of the numerical models), illustrating the time evolution of slab interactions with the lower mantle as seen in such fields as velocity magnitude, strain rate, viscosity, as well as the toroidal and poloidal components of induced flow. This investigation is well-suited to developing direct comparisons with geological and geophysical observations such as geodetically determined hinge retreat rates, geochemical and petrological observations of arc volcanics and back-arc ridge basalts, timing and distribution of metamorphic core complexes in backarc basins under extension, paleostress observables such surface movements and block rotations, observations of seismic anistropy determined by shear wave splitting, and the emerging studies of regional tomographic models of seismic anistropy.
Rigid collapsible dish structure
NASA Technical Reports Server (NTRS)
Palmer, William B. (Inventor); Giebler, Martin M. (Inventor)
1982-01-01
A collapsible dish structure composed of a plurality of rows of rigid radial petal assemblies concentric with the axis of the dish. The petal assemblies consist of a center petal and two side petals, the center petal hinged on an axis tangent to a circle concentric with the axis of the dish and the side petals hinged to the center petal at their mating edge. The center petal is foldable inwardly and the side petals rotate about their hinges such that the collapsed dish structure occupies a much smaller volume than the deployed dish. Means of controlling the shape of the dish to compensate for differential expansion of the deployed dish are also provided.
DETAIL VIEW OF WINCH USED TO RAISE AND LOWER HINGED ...
DETAIL VIEW OF WINCH USED TO RAISE AND LOWER HINGED SECTION OF THIRD FLOOR LEVEL, PLATFORM D-SOUTH, HB-3, FACING WEST - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
78 FR 15281 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-11
... horizontal stabilizer. This AD requires repetitive high frequency eddy current (HFEC) inspections for... repetitive high frequency eddy current (HFEC) inspections for cracking of the left and right rib hinge... high frequency eddy current (HFEC) inspection for cracking of the left and right rib hinge bearing lugs...
Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.
2011-01-01
Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701
Wu, Yi; Dabhoiwala, Noshir F; Hagoort, Jaco; Tan, Li-Wen; Zhang, Shao-Xiang; Lamers, Wouter H
2017-05-01
The pelvic floor guards the passage of the pelvic organs to the exterior. The near-epidemic prevalence of incontinence in women continues to generate interest in the functional anatomy of the pelvic floor. However, due to its complex architecture and poor accessibility, the classical 'dissectional' approach has been unable to come up with a satisfactory description, so that many aspects of its anatomy continue to raise debate. For this reason, we opted for a 'sectional' approach, using the Chinese Visible Human project (four females, 21-35 years) and the Visible Human Project (USA; one female, 59 years) datasets to investigate age-related changes in the architecture of the anterior and middle compartments of the pelvic floor. The puborectal component of the levator ani muscle defined the levator hiatus boundary. The urethral sphincter complex consisted of a circular proximal portion (urethral sphincter proper), a sling that passed on the vaginal wall laterally to attach to the puborectal muscle (urethral compressor), and a circular portion that surrounded the distal urethra and vagina (urethrovaginal sphincter). The exclusive attachment of the urethral sphincter to soft tissues implies dependence on pelvic-floor integrity for optimal function. The vagina was circular at the introitus and gradually flattened between bladder and rectum. Well-developed fibrous tissue connected the inferior vaginal wall with urethra, rectum and pelvic floor. With eight-muscle insertions, the perineal body was a strong, irregular fibrous node that guarded the levator hiatus. Only loose areolar tissue comprising a remarkably well developed venous plexus connecting the middle and superior parts of the vagina with the lateral pelvic wall. The posterolateral boundary of the putative cardinal and sacrouterine ligaments coincided with the adventitia surrounding the mesorectum. The major difference between the young-adult and postmenopausal pelvic floor was the expansion of fat in between the components of the pelvic floor. We hypothesize that accumulation of pelvic fat compromises pelvic-floor cohesion, because the pre-pubertal pelvis contains very little fibrous and adipose tissue, and fat is an excellent lubricant. © 2017 Anatomical Society.
Shah, Mamta; Lee, Grace; Lefebvre, Daniel R.; Kronberg, Benjamin; Loomis, Stephanie; Brauner, Stacey C.; Turalba, Angela; Rhee, Douglas J.; Freitag, Suzanne K.; Pasquale, Louis R.
2013-01-01
We studied the relation between prostaglandin analogue use and ocular adnexal features. We used a prospective, cross-sectional study involving 157 current, 15 past, and 171 never users of prostaglandin analogues. Patients 50 years of age or older and without conditions affecting ocular adnexal anatomy underwent glaucoma medication use history, external digital photography and systematic external adnexal exam. Two masked readers assessed the digital photos for upper lid dermatochalasis and lower lid steatoblepharon using a validated grading scheme. Another masked clinical examiner also assessed upper lid ptosis, levator muscle function, and inferior scleral show. We performed ordinal logistic regression analysis accounting for multiple covariates to assess the relation between prostaglandin analogue use and adnexal features. Multivariable analyses indicated there was a 230-fold increased risk of incremental involution of dermatochalasis (odds ratio (OR) = 2.30; 95% confidence interval (CI) 1.43–3.69; p = 5.44E-04) and a 249-fold increased risk of incremental loss of lower lid steatoblepharon (OR = 2.49; 95% CI, 1.54–4.03; p = 1.98E-04) associated with current prostaglandin analogue use (bimatoprost 0.03%, travoprost 0.005%, or latanoprost 0.004%) versus prostaglandin analogue never or past users. Upper lid ptosis (OR = 4.04; 95% CI, 2.43–6.72; p = 7.37E-08), levator dysfunction (OR = 7.51; 95% CI, 3.39–16.65; p = 6.74E-07) and lower lid retraction (OR = 2.60; 95% CI, 1.58–4.28; p = 1.72E-04) were highly associated with current prostaglandin analogue use versus prostaglandin analogue never or past users. The associations between prostaglandin analogue use and deepening of the upper lid sulci and between prostaglandin analogue use and loss of inferior periorbital fat are confirmed in this multivariable analysis. The associations between prostaglandin analogue use and levator muscle dysfunction and between prostaglandin analogue use and upper lid ptosis represent significant side effects that could impact visual function in glaucoma patients. PMID:23650502
Hinge specification for a square-faceted tetrahedral truss
NASA Technical Reports Server (NTRS)
Adams, L. R.
1984-01-01
A square-faceted tetrahedral truss is geometrically analyzed. Expressions are developed for single degree of freedom hinges which allow packaging of the structure into a configuration in which all members are parallel and closely packed in a square pattern. Deployment is sequential, thus providing control over the structure during deployment.
NASA Technical Reports Server (NTRS)
Death, M. D.
1984-01-01
The evolution of an Antenna Deployment Mechanism (ADM) from a Hinge Actuator Mechanism (HAM) is described as it pertains to the deployment of large satellite antennas. Design analysis and mechanical tests are examined in detail.
78 FR 24985 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-29
... (L-126A,B,C), 195A, and 195B airplanes that are equipped with certain inboard aileron hinge brackets... 4, 2013), currently requires you to repetitively inspect the affected inboard aileron hinge brackets... brackets. Replacement with aluminum brackets would terminate the need for the repetitive inspections...
14 CFR 23.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) K=24 for vertical surfaces; (2) K=12 for horizontal surfaces; and (3) W=weight of the movable... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Loads parallel to hinge line. 23.393 Section 23.393 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...
14 CFR 23.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) K=24 for vertical surfaces; (2) K=12 for horizontal surfaces; and (3) W=weight of the movable... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Loads parallel to hinge line. 23.393 Section 23.393 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...
14 CFR 23.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) K=24 for vertical surfaces; (2) K=12 for horizontal surfaces; and (3) W=weight of the movable... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Loads parallel to hinge line. 23.393 Section 23.393 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...
14 CFR 23.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) K=24 for vertical surfaces; (2) K=12 for horizontal surfaces; and (3) W=weight of the movable... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Loads parallel to hinge line. 23.393 Section 23.393 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...
14 CFR 23.393 - Loads parallel to hinge line.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) K=24 for vertical surfaces; (2) K=12 for horizontal surfaces; and (3) W=weight of the movable... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Loads parallel to hinge line. 23.393 Section 23.393 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...
49 CFR 571.224 - Standard No. 224; Rear impact protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the vehicle is in motion. Nonstructural protrusions such as taillights, rubber bumpers, hinges and... deliver asphalt and other road building materials, in a controlled horizontal manner, into a lay down... protrusions such as taillights, hinges, rubber bumpers, and latches are excluded from the determination of the...
61. DETAIL OF HEAD, VANE STEM, VANE HINGE, AND WHEEL ...
61. DETAIL OF HEAD, VANE STEM, VANE HINGE, AND WHEEL OF AN ELI WINDMILL ON THE GROUND AT THE STOLL RESIDENCE ABOUT 1-1/2 MILES WEST OF NEBRASKA CITY ON STEAM WAGON ROAD. - Kregel Windmill Company Factory, 1416 Central Avenue, Nebraska City, Otoe County, NE
Angular motion equations for a satellite with hinged flexible solar panel
NASA Astrophysics Data System (ADS)
Ovchinnikov, M. Yu.; Tkachev, S. S.; Roldugin, D. S.; Nuralieva, A. B.; Mashtakov, Y. V.
2016-11-01
Non-linear mathematical model for the satellite with hinged flexible solar panel is presented. Normal modes of flexible elements are used for motion description. Motion equations are derived using virtual work principle. A comparison of normal modes calculation between finite element method and developed model is presented.
[COSMOS motion design optimization in the CT table].
Shang, Hong; Huang, Jian; Ren, Chao
2013-03-01
Through the CT Table dynamic simulation by COSMOS Motion, analysis the hinge of table and the motor force, then optimize the position of the hinge of table, provide the evidence of selecting bearing and motor, meanwhile enhance the design quality of the CT table and reduce the product design cost.
NASA Technical Reports Server (NTRS)
Lindsey, A. I.; Milam, M. D.
1974-01-01
Aerodynamic investigations were conducted in a transonic pressure tunnel on an 0.015 scale model of the space shuttle orbiter. Major test objectives were to determine: (1) transonic differential elevon/aileron lateral control optimization; (2) transonic elevon hinge moments; (3) transonic effects of the baseline 6 inch elevon/elevon and elevon/fuselage gaps; and (4) transonic effects of the short OMS pods. Six-component aerodynamic force and moment, and elevon hinge moment data, were recorded over an angle-of-attack range form -2 to +22 degrees.
Bersani, D; Campani, E; Casoli, A; Lottici, P P; Marino, I-G
2008-03-03
Two holy water fonts (dated at the beginning of the XVII century) in the Santa Maria della Steccata Church in Parma (Italy) have recently been restored. Before the intervention, a detailed investigation on their degradation products was carried out to understand the mechanisms of alteration of the materials and to suggest appropriate restoration procedures. The analyses were performed by means of powder X-ray diffraction (XRD), micro-Fourier transform infrared (FTIR) and micro-Raman spectroscopies. Calcite, iron oxides, silicates and sodium chloride (from salted holy water) were found in the red coloured calcarenite. On and under the lead coverings, different lead oxides (mainly massicot), other lead salts (lead basic carbonate, cerussite, plumbonacrite Pb10O(OH)6(CO3)6 and lead-chlorine compounds as laurionite PbOHCl and phosgenite Pb2CO3Cl2) were identified by Raman spectroscopy and XRD. Haematite alpha-Fe2O3, goethite alpha-FeO(OH) and lepidocrocite gamma-FeO(OH) were found on and around the iron hinges. Lead compounds and sodium chloride, through crystallization and solubilization cycles, were responsible for the stone's degradation, whereas the iron corrosion materials on the hinges produced mechanical stress and cracks in the stone. Various suggestions have been given on how to restore these fonts and to remove the causes of damage.
Heyberger, Clémence; Auberger, Guillaume; Babinet, Antoine; Anract, Philippe; Biau, David J
2017-12-21
We asked whether there would be any difference between primary and revision modern cemented fixed hinge megaprosthesis of the distal femur in function and activity-related outcomes following treatment of a bone tumor. An identical custom-made fixed hinge cemented megaprosthesis with a hydroxyapatite collar was used in all cases. The main outcomes were joint-specific function, disease-specific activity, and health-related quality of life. Implant survival was also evaluated. Patients in the revision group performed slightly better than patients in the primary group on disease-specific (Toronto Extremity Salvage Score, p = 0.033; Musculoskeletal Tumor Society, p = 0.072) and health-related outcomes (Short Form 36 [SF-36] physical component, p = 0.085; SF-36 mental component, p = 0.069) but not on joint-specific outcomes (Knee Society Score, p = 0.94). The cumulative probabilities of revision for any reason were 14.5% (7-25%) at 5 years with no statistically significant difference between primary and revision procedures ( p = 0.77). In conclusion, patients undergoing a revision have similar joint-specific functional outcome but improved disease-specific and health-related outcomes. Implant survival are similar between groups. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Effect of hinge-moment parameters on elevator stick forces in rapid maneuvers
NASA Technical Reports Server (NTRS)
Jones, Robert T; Greenberg, Harry
1944-01-01
The importance of the stick force per unit normal acceleration as a criterion of longitudinal stability and the critical dependence of this gradient on elevator hinge-moment parameters have been shown in previous reports. The present report continues the investigation with special reference to transient effects for maneuvers of short duration.
Deployable video conference table
NASA Technical Reports Server (NTRS)
Cohen, Marc M. (Inventor); Lissol, Peter (Inventor)
1993-01-01
A deployable table is presented. The table is stowed in and deployed from a storage compartment based upon a non-self rigidizing, 4-hinge, arch support structure that folds upon itself to stow and that expands to deploy. The work surfaces bypass each other above and below to allow the deployment mechanism to operate. This assembly includes the following: first and second primary pivot hinges placed at the opposite ends of the storage compartment; first and second lateral frame members with proximal ends connected to the first and second pivot hinges; a medial frame member offset from and pivotally connected to distal ends of the first and second members through third and fourth medial pivot hinges; and left-side, right-side, and middle trays connected respectively to the first, second, and third frame members and being foldable into and out of the storage compartment by articulation of the first, second, third, and fourth joints. At least one of the third and fourth joints are locked to set the first, second, and third frame members in a desired angular orientation with respect to each other.
Operational characterization of CSFH MEMS technology based hinges
NASA Astrophysics Data System (ADS)
Crescenzi, Rocco; Balucani, Marco; Belfiore, Nicola Pio
2018-05-01
Progress in MEMS technology continuously stimulates new developments in the mechanical structure of micro systems, such as, for example, the concept of so-called CSFH (conjugate surfaces flexural hinge), which makes it possible, simultaneously, to minimize the internal stresses and to increase motion range and robustness. Such a hinge may be actuated by means of a rotary comb-drive, provided that a proper set of simulations and tests are capable to assess its feasibility. In this paper, a CSFH has been analyzed with both theoretical and finite element (FEM) methods, in order to obtain the relation between voltage and generated torque. The FEM model considers also the fringe effect on the comb drive finger. Electromechanical couple-field analysis is performed by means of both direct and load transfer methods. Experimental tests have been also performed on a CSFH embedded in a MEMS prototype, which has been fabricated starting from a SOI wafer and using D-RIE (deep reactive ion etching). Results showed that CSFH performs better than linear flexure hinges in terms of larger rotations and less stress for given applied voltage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butrapet, Siritorn; Childers, Thomas; Moss, Kelley J.
Fifteen mutant dengue viruses were engineered and used to identify AAs in the molecular hinge of the envelope protein that are critical to viral infection. Substitutions at Q52, A54, or E133 reduced infectivity in mammalian cells and altered the pH threshold of fusion. Mutations at F193, G266, I270, or G281 affected viral replication in mammalian and mosquito cells, but only I270W had reduced fusion activity. T280Y affected the pH threshold for fusion and reduced replication in C6/36 cells. Three different mutations at L135 were lethal in mammalian cells. Among them, L135G abrogated fusion and reduced replication in C6/36 cells, butmore » only slightly reduced the mosquito infection rate. Conversely, L135W replicated well in C6/36 cells, but had the lowest mosquito infection rate. Possible interactions between hinge residues 52 and 277, or among 53, 135, 170, 186, 265, and 276 required for hinge function were discovered by sequence analysis to identify compensatory mutations.« less
Anterior knee symptoms after S-ROM hinge implantation.
Deehan, David J; Gangadharan, Rajkumar; Malviya, Ajay; Sutherland, Alasdair; Holland, James P
2014-01-01
To evaluate the performance of a canal filling hinge device for complex knee arthroplasty. Thirty-seven (4 primary hinge implantation and 33 revision cases) patients who had undergone arthroplasty with the S-ROM third generation hinge device for a combination of massive bone loss or ligamentous insufficiency were prospectively examined with a minimum of 5-year follow-up. Median age at surgery was 72 years (range: 43 to 87 years). Principal indications included aseptic loosening or massive osteolysis (24 cases), infection (8 cases) and periprosthetic fracture (4 cases). All patients exhibited either grade 2 (N = 12) or grade 3 (N = 25) AORI bone loss or a grade 3 medial ligament deficiency. One patient experienced implant failure (71 months), and one patient suffered late deep infection (36 months). Mean WOMAC score improved from 27 to 62. Four patients required patellar resurfacing for persistent pain. The 5-year survivorship was 86%. While the S-ROM device may offer satisfactory medium term outcome for complex end stage knee disease, we report a high rate of debilitating anterior knee symptoms.
NASA Technical Reports Server (NTRS)
McCarty, John Locke; Brooks, George W.; Maglieri, Domenic J.
1959-01-01
A two-blade rotor having a diameter of 4 feet and a solidity of 0.037 was tested in the Langley 300-MPH 7- by 10-foot tunnel to obtain information on the effect of certain rotor variables on the blade periodic bending moments and flapping angles during the various stages of transformation between the helicopter and autogiro configuration. Variables studied included collective pitch angle, flapping-hinge offset, rotor angle of attack, and tip-speed ratio. The results show that the blade periodic bending moments generally increase with tip-speed ratio up into the transition region, diminish over a certain range of tip-speed ratio, and increase again at higher tip-speed ratios. Above the transition region, the bending moments increase with collective pitch angle and rotor angle of attack. The absence of a flapping hinge results in a significant amplification of the periodic bending moments, the magnitudes of which increase with tip-speed ratio. When the flapping hinge is used, an increase in flapping-hinge offset results in reduced period bending moments. The aforementioned trends exhibited by the bending moments for changes in the variables are essentially duplicated by the periodic flapping motions. The existence of substantial amounts of blade stall increased both the periodic bending moments and the flapping angles. Harmonic analysis of the bending moments shows significant contributions of the higher harmonics, particularly in the transition region.
Comparison of platelet activation through hinge vs bulk flow in mechanical heart valves
NASA Astrophysics Data System (ADS)
Hedayat, Mohammadali; Borazjani, Iman
2017-11-01
Bileaflet mechanical heart valves increase the risk of thrombus formation in patients which is believed to be initiated by platelet activation. Platelets can be activated by the elevated shear stresses in the bulk flow during the systole phase or the flow through the hinge during the diastole. However, the importance of platelet activation by the bulk flow vs the hinge in MHVs has yet to be studied. Here, we investigate the contribution of each of the above mechanisms to the activation of platelets in MHs by performing simulation of the flow through a 25mm St. Jude Medical valve placed in a straight aorta. Two different gap sizes (250 and 150 micrometer) are used in this study. The simulations are done using a sharp interface curvilinear immersed boundary method along with a strong-coupling algorithm for FSI solver on overset grids. The platelet activation through the hinge for different gap sizes is compared to the activation in the bulk flow using two platelet activation models to ensure the consistency of the results. Our results for all gap sizes using different activation models show that the integration of platelet activation caused by the bulk flow is several times higher in comparison to the activation through the hinge. This work is supported by the American Heart Association Grant 13SDG17220022, and the computational resources were partly provided by Center for Computational Research (CCR) at University at Buffalo.
Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C
2011-11-01
Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.
Levator alae nasi muscle V-Y island flap for nasal tip reconstruction.
La Padula, Simone; Abbate, Vincenzo; Di Monta, Gianluca; Schonauer, Fabrizio
2017-03-01
Nasal tip reconstruction can be very challenging. It requires close attention to skin texture, colour and thickness matching, with the respect of the nasal aesthetic units and symmetry. Flaps are usually preferred to skin grafts where possible. Based on different donor areas, various flaps have been described for reconstruction of this region. Here we present a new V-Y myocutaneous island flap based on the levator alae nasi muscle (LAN muscle) blood supply. This flap may represent an alternative to the nasalis myocutaneous sliding V-Y flap previously described by Rybka. As its pivot point it is located more cranially than the nasalis flap, and it can advance more medially than the Rybka flap, with the possibility of covering larger defects of the nasal tip area, up to 1.8 cm in diameter. Over the past 5 years, 24 patients received nasal tip reconstruction with this flap following the resection of basal cell carcinomas. Good tip projection was maintained, and the aesthetic outcome was satisfactory, with well healed scars. We recommend this technique as an alternative to other flaps for nasal tip defects, especially if paramedian. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Anatomical study of the opossum (Didelphis albiventris) extraocular muscles.
Matheus, S M; Soares, J C; da Silva, A M; Seullner, G
1995-01-01
The anatomy of the extraocular muscles was studied in 10 adult opossums (Didelphis albiventris) of both sexes. Eight extraocular muscles were identified: 4 rectus muscles, 2 oblique muscles, the levator palpebrae superioris and the retractor ocular bulbi. The rectus muscles originate very close one to another between the orbital surfaces of the presphenoid and palatine bones. These muscles diverge on the way to their insertion which occurs at about 2 mm from the limbus. The levator palpebrae superioris originates with the dorsal rectus and is positioned dorsally in relation to it. The retractor ocular bulbi forms a cone which embraces the optic nerve and is located internally in relation to the rectus muscles. The dorsal oblique originates on the presphenoid bone and after a tendinous trajectory through a trochlea on the medial wall of the orbit, inserts into the ocular bulb. The only muscle arising from the anterior orbital floor is the ventral oblique. The main nerve supply for these muscles is the oculomotor, except for the dorsal oblique which is innervated by the trochlear nerve, and the lateral rectus which is innervated by the abducens nerve. The retractor ocular bulbi receives branches from the inferior division of the oculomotor nerve and some branches from the abducens nerve. Images Fig. 1 Fig. 2 Fig. 3 PMID:7649843
Variations in Velopharyngeal Structure in Adults With Repaired Cleft Palate.
Perry, Jamie L; Kotlarek, Katelyn J; Sutton, Bradley P; Kuehn, David P; Jaskolka, Michael S; Fang, Xiangming; Point, Stuart W; Rauccio, Frank
2018-01-01
The purpose of this study was to examine differences in velopharyngeal structures between adults with repaired cleft palate and normal resonance and adults without cleft palate. Thirty-six English-speaking adults, including 6 adults (2 males and 4 females) with repaired cleft palate (M = 32.5 years of age, SD = 17.4 years) and 30 adults (15 males and 15 females) without cleft palate (M = 23.3 years of age, SD = 4.1 years), participated in the study. Fourteen velopharyngeal measures were obtained on magnetic resonance images and compared between groups (cleft and noncleft). After adjusting for body size and sex effects, there was a statistically significant difference between groups for 10 out of the 14 velopharyngeal measures. Compared to those without cleft palate, participants with repaired cleft palate had a significantly shorter hard palate height and length, shorter levator muscle length, shorter intravelar segment, more acute levator angles of origin, shorter and thinner velum, and greater pharyngeal depth. Although significant differences were evident in the cleft palate group, individuals displayed normal resonance. These findings suggest that a wide variability in velopharyngeal anatomy can occur in the presence of normal resonance, particularly for those with repaired cleft palate. Future research is needed to understand how anatomic variability impacts function, such as during speech.
Klem, Nardia-Rose; Wild, Catherine Y; Williams, Sian A; Ng, Leo
2017-03-01
Despite the high prevalence of lower extremity injuries in female basketball players as well as a high proportion of athletes who wear ankle braces, there is a paucity of research pertaining to the effects of ankle bracing on ankle and knee biomechanics during basketball-specific tasks. To compare the effects of a lace-up brace (ASO), a hinged brace (Active T2), and no ankle bracing (control) on ankle and knee joint kinematics and joint reaction forces in female basketball athletes during a cutting maneuver. Controlled laboratory study. Twenty healthy, semi-elite female basketball players performed a cutting task under both ankle brace conditions (lace-up ankle brace and hinged ankle brace) and a no-brace condition. The 3-dimensional kinematics of the ankle and knee during the cutting maneuver were measured with an 18-camera motion analysis system (250 Hz), and ground-reaction force data were collected by use of a multichannel force plate (2000 Hz) to quantify ankle and knee joint reaction forces. Conditions were randomized using a block randomization method. Compared with the control condition, the hinged ankle brace significantly restricted peak ankle inversion (mean difference, 1.7°; P = .023). No significant difference was found between the lace-up brace and the control condition ( P = .865). Compared with the lace-up brace, the hinged brace significantly reduced ankle and knee joint compressive forces at the time of peak ankle dorsiflexion (mean difference, 1.5 N/kg [ P = .018] and 1.4 N/kg [ P = .013], respectively). Additionally, the hinged ankle brace significantly reduced knee anterior shear forces compared with the lace-up brace both during the deceleration phase and at peak ankle dorsiflexion (mean difference, 0.8 N/kg [ P = .018] and 0.9 N/kg [ P = .011], respectively). The hinged ankle brace significantly reduced ankle inversion compared with the no-brace condition and reduced ankle and knee joint forces compared with the lace-up brace in a female basketball population during a cutting task. Compared with the lace-up brace, the hinged brace may be a better choice of prophylactic ankle support for female basketball players from a biomechanical perspective. However, both braces increased knee internal rotation and knee abduction angles, which may be problematic for a population that already has a high prevalence of knee injuries.
Anatomy of the lateral ligaments of the rectum: a controversial point of view.
Wang, Guo-Jun; Gao, Chun-Fang; Wei, Dong; Wang, Cun; Meng, Wen-Jian
2010-11-21
The existence and composition of the lateral ligaments of the rectum (LLR) are still the subjects of anatomical confusion and surgical misconception up to now. Since Miles proposed abdominoperineal excision as radical surgery for rectal cancer, the identification by "hooking them on the finger" has been accepted by many surgeons with no doubt; clamping, dividing and ligating are considered to be essential procedures in mobilization of the rectum in many surgical textbooks. But in cadaveric studies, many anatomists could not find LLR described by the textbooks, and more and more surgeons also failed to find LLR during the proctectomy according to the principle of total mesorectal excision. The anatomy of LLR has diverse descriptions in literatures. According to our clinical observations, the traditional anatomical structures of LLR do exist; LLR are constant dense connective bundles which are located in either lateral side of the lower part of the rectum, run between rectal visceral fascia and pelvic parietal fascia above the levator ani, and covered by superior fascia of pelvic diaphragm. They are pathways of blood vessels and nerve fibers toward the rectum and lymphatic vessels from the lower rectum toward the iliac lymph nodes.
Anatomy of the lateral ligaments of the rectum: A controversial point of view
Wang, Guo-Jun; Gao, Chun-Fang; Wei, Dong; Wang, Cun; Meng, Wen-Jian
2010-01-01
The existence and composition of the lateral ligaments of the rectum (LLR) are still the subjects of anatomical confusion and surgical misconception up to now. Since Miles proposed abdominoperineal excision as radical surgery for rectal cancer, the identification by “hooking them on the finger” has been accepted by many surgeons with no doubt; clamping, dividing and ligating are considered to be essential procedures in mobilization of the rectum in many surgical textbooks. But in cadaveric studies, many anatomists could not find LLR described by the textbooks, and more and more surgeons also failed to find LLR during the proctectomy according to the principle of total mesorectal excision. The anatomy of LLR has diverse descriptions in literatures. According to our clinical observations, the traditional anatomical structures of LLR do exist; LLR are constant dense connective bundles which are located in either lateral side of the lower part of the rectum, run between rectal visceral fascia and pelvic parietal fascia above the levator ani, and covered by superior fascia of pelvic diaphragm. They are pathways of blood vessels and nerve fibers toward the rectum and lymphatic vessels from the lower rectum toward the iliac lymph nodes. PMID:21086557
[Therapy-resistant swelling of the upper eyelid in childhood].
Haustein, M; Terai, N; Pablik, J; Pillunat, L E; Sommer, F
2014-01-01
Swelling of the upper eyelid in childhood is caused by a variety of diseases and is very often generated by inflammation but orbital tumors should always be considered in the differential diagnostics. We report about a 4-year-old girl with a drug-resistant swelling of the upper eyelid and ptosis of the right eye. This case report demonstrates the route from initial clinical examination to diagnosis and additionally reviews the current status of therapeutic options. After magnetic resonance imaging (MRI) and diagnostic excision, Langerhans cell histiocytosis (LCH) could be histologically proven. Visual acuity and levator muscle function improved from 0.5 to 1.25 and from 2 mm to 12 mm, respectively, by amblyopic prophylaxis and immunosuppressive therapy. Persistent and drug-resistant swelling of the upper eyelid in childhood is also strongly suspicious for tumors. The suspicion of rare orbital tumors in children can be frequently substantiated by MRI. Biopsy and histological diagnosis are essential to plan adequate treatment and to estimate the prognosis. Particularly in Langerhans cell histiocytosis the methods of choice for over 10 years are specific immunochemical procedures (detection of protein s100 and CD1a).
77 FR 20515 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-05
... attachment fittings and the swan neck with serviceable ones if necessary. This AD was prompted by reports of cracks on the forward attachment fittings of the left and right sides of the forward hinge of the nose... (FWD) fittings (hinge 5) of the NLG aft doors (Right Hand (RH) side or Left Hand (LH) side). The cracks...
75 FR 22543 - Airworthiness Directives; Aircraft Industries a.s. Model L 23 Super Blanik Gliders
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-29
... unsafe condition as: Cracks on the stabilizer elevator inner hinges of seven L 23 SUPERBLAN[Iacute]K... the need for the immediate inspection of the elevator inner hinges on the stabilizer. The European Aviation Safety Agency (EASA), which is the Technical Agent for the Member States of the European Community...
75 FR 17295 - Airworthiness Directives; Aircraft Industries a.s. Model L 23 Super Blanik Gliders
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-06
... elevator inner hinges of seven L 23 SUPERBLAN[Iacute]K sailplanes have been detected during an inspection... European Aviation Safety Agency (EASA), which is the Technical Agent for the Member States of the European... stabilizer elevator inner hinges of seven L 23 SUPERBLAN[Iacute]K sailplanes have been detected during an...
NASA Technical Reports Server (NTRS)
Esparza, V.
1975-01-01
Experimental aerodynamic investigations were conducted in the Arnold Engineering Development Center (AEDC) Von Karman Facility Tunnel A on a scale model of the space shuttle orbiter. The objectives of this test were: (1) determine supersonic differential elevon/aileron lateral control optimization, (2) determine supersonic elevon hinge moments, (3) determine the supersonic effects of the new baseline 6-inch elevon/elevon and elevon/fuselage gaps, and 4) determine the supersonic effects of the new short (VL70-008410) OMS pods. Six-component aerodynamic force, moment, and elevon hinge moment data were recorded.
Wind-Tunnel Investigation of the Effect of Tab Balance on Tab and Control-Surface Characteristics
NASA Technical Reports Server (NTRS)
Brewer, Jack D; Queijo, M J
1947-01-01
An investigation was conducted to furnish data on the effect of tab balance on tab and control-surface characteristics. The airfoil tested had a modified NACA 65(1)-012 contour with a plain flap having a chord equal to 25 percent of the wing chord and with a tab having a chord equal to 25 percent of the flap chord and having several nose shapes and overhang lengths. The results of the investigation indicated that, in general, tab balance affected tab hinge-moment characteristics in much the same manner that flap balance affects flap hinge-moment characteristics. A moderate amount of tab balance did not seem to have any adverse effect on flap hinge-moment characteristics.
Apparatus for raising or tilting a micromechanical structure
Allen, James J [Albuquerque, NM
2008-09-09
An active hinge apparatus is disclosed which can be used to raise a micromechanical structure (e.g. a plate or micromirror) on a substrate. The active hinge apparatus utilizes one or more of teeth protruding outward from an axle which also supports the micromechanical structure on one end thereof. A rack is used to engage the teeth and rotate the axle to raise the micromechanical structure and tilt the structure at an angle to the substrate. Motion of the rack is provided by an actuator which can be a mechanically-powered actuator, or alternately an electrostatic comb actuator or a thermal actuator. A latch can be optionally provided in the active hinge apparatus to lock the micromechanical structure in an "erected" position.
[Sonographic evaluation of the levator ani muscle in women with stress urinary incontinence].
Stachowicz, Norbert; Stachowicz, Sylwia; Smoleń, Agata; Morawska, Dorota; Kotarski, Jan
2012-09-01
Three-dimensional sonography has been used for about 15 years, not only to examine the female genital organs, but also the lower urinary tract and pelvic floor. Three-dimensional sonography offers more information than traditional two-dimensional sonography allowing for a dynamic representation of the examined structures and observation at any angle necessary. Translabial sonography is the best way of a sonographic examination of the lower urinary tract, because it does not affect the mutual relationship of any parts in the lower pelvic area, contrary to the transrectal or transvaginal probes. In order to establish proper treatment of the urinary incontinence symptoms, not only a functional examination of the lower urinary tract, but also a very accurate assessment of the statics of the female genital organs and pelvic floor need to be performed. The aim of the study was to rate the area and diameters of the limbs of the levator ani muscle using a three-dimensional (3D) translabial sonography in women with stress urinary incontinence without the female genital tract prolapse. The study group included 100 patients who were examined with the GE Kretz Voluson 730 (GE, Austria), equipped with 6-9 MHz translabial probe. The first group with stress urinary incontinence consisted of 50 women (mean age 56.22 (+/- 10.43) years) and the second group included 50 women without symptoms (mean age 49.40 (+/- 13.22) years). All cases of urinary stress incontinence in the first group were confirm by means of a urodynamic examination. Women in both groups had similar body weight (kilograms), mean (+/- SD): 26.88 (+/- 2.02) and 26.20 (+/- 4,14), respectively. Menopausal status in both groups was not statistically significant and amounted to 7.21 (+/- 8.71) in the group of women with stress urinary incontinence and 4.70 (+/- 6.32) in the group without symptoms. Mean (+/- SD) number of deliveries was significantly higher in the group of women with stress urinary incontinence than in the control group (2.40 (+/- 1.03) and 1.56 (+/- 1.34), respectively). In all cases 3D coronal view of the pelvic diaphragm was obtained and the area and thickness of limbs of the levator ani muscle were measured. All women had about 200 ml urine in the bladder. The results are presented as means +/- SD. Mean measurements of this area in both groups were 8.54 +/- 1.62 cm2 and 10.57 +/- 1.29 cm2, respectively. Mean thickness of the limbs in the groups were: 8.72 +/- 0.64mm and 10.85 +/- 0.89mm on the left side and 8.85 +/- 0.67mm and 10.89 +/- 0.87mm on right side, respectively. The differences between both groups in all measurements were statistically significant (p < 0.001). There are some differences involving measurements of the thickness and the area of the limbs of the levator ani muscle in women with and without stress urinary incontinence and without the genital tract prolapse in both groups. The observed differences could have implications in physiotherapy of the pelvic floor muscles in women without statics abnormalities.
Folding Polyominoes from One Level to Two
ERIC Educational Resources Information Center
Frederickson, Greg N.
2011-01-01
For any given polyomino, is it possible to cut it into pieces and then hinge the pieces, so that the polyomino folds up into a similar version of itself but two levels thick? While we don't know how to do this for every polyomino, the article does show how to cut, hinge, and fold polyominoes from several infinite classes, providing an…
49 CFR 571.206 - Standard No. 206; Door locks and door retention components.
Code of Federal Regulations, 2012 CFR
2012-10-01
... (GVWR) of 4,536 kg or less. S3. Definitions. Auxiliary Door Latch is a latch equipped with a fully... auxiliary door latch on each hinged door shall not disengage from the fully latched position when an inertia... hinged back door shall also not disengage from the fully latched position when an inertia load is applied...
49 CFR 571.206 - Standard No. 206; Door locks and door retention components.
Code of Federal Regulations, 2013 CFR
2013-10-01
... (GVWR) of 4,536 kg or less. S3. Definitions. Auxiliary Door Latch is a latch equipped with a fully... auxiliary door latch on each hinged door shall not disengage from the fully latched position when an inertia... hinged back door shall also not disengage from the fully latched position when an inertia load is applied...
49 CFR 571.206 - Standard No. 206; Door locks and door retention components.
Code of Federal Regulations, 2011 CFR
2011-10-01
... (GVWR) of 4,536 kg or less. S3. Definitions. Auxiliary Door Latch is a latch equipped with a fully... auxiliary door latch on each hinged door shall not disengage from the fully latched position when an inertia... hinged back door shall also not disengage from the fully latched position when an inertia load is applied...
49 CFR 571.206 - Standard No. 206; Door locks and door retention components.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (GVWR) of 4,536 kg or less. S3. Definitions. Auxiliary Door Latch is a latch equipped with a fully... auxiliary door latch on each hinged door shall not disengage from the fully latched position when an inertia... hinged back door shall also not disengage from the fully latched position when an inertia load is applied...
NASA Astrophysics Data System (ADS)
Iai, Masafumi; Durali, Mohammad; Hatsuzawa, Takeshi
Recent research has been extending the applications of small satellites called microsatellites, nanosatellites, or picosatellites. To further improve capability of those satellites, a lightweight, active attitude-control mechanism is needed. This paper proposes a concept of inertial orientation control, an attitude control method using movable solar arrays. This method is made suitable for nanosatellites by the use of shape memory alloy (SMA)-actuated elastic hinges and a simple maneuver generation algorithm. The combination of SMA and an elastic hinge allows the hinge to remain lightweight and free of frictional or rolling contacts. Changes in the shrinking and stretching speeds of the SMA were measured in a vacuum chamber. The proposed algorithm constructs a maneuver to achieve arbitrary attitude change by repeating simple maneuvers called unit maneuvers. Provided with three types of unit maneuvers, each degree of freedom of the satellite can be controlled independently. Such construction requires only simple calculations, making it a practical algorithm for a nanosatellite with limited computational capability. In addition, power generation variation caused by maneuvers was analyzed to confirm that a maneuver from any initial attitude to an attitude facing the sun was justifiable in terms of the power budget.
Kerkum, Yvette L; Brehm, Merel-Anne; Buizer, Annemieke I; van den Noort, Josien C; Becher, Jules G; Harlaar, Jaap
2014-12-01
A rigid ventral shelf ankle foot orthosis (AFO) may improve gait in children with spastic cerebral palsy (SCP) whose gait is characterized by excessive knee flexion in stance. However, these AFOs can also impede ankle range of motion (ROM) and thereby inhibit push-off power. A more spring-like AFO can enhance push-off and may potentially reduce walking energy cost. The recent development of an adjustable spring-hinged AFO now allows adjustment of AFO stiffness, enabling tuning toward optimal gait performance. This study aims to quantify the mechanical properties of this spring-hinged AFO for each of its springs and settings. Using an AFO stiffness tester, two AFO hinges and their accompanying springs were measured. The springs showed a stiffness range of 0.01-1.82 N · m · deg(-1). The moment-threshold increased with increasing stiffness (1.13-12.1 N · m), while ROM decreased (4.91-16.5°). Energy was returned by all springs (11.5-116.3 J). These results suggest that the two stiffest available springs should improve joint kinematics and enhance push-off in children with SCP walking with excessive knee flexion.
Helmstaedt, Kerstin; Heinrich, Gabriele; Lipscomb, William N.; Braus, Gerhard H.
2002-01-01
The yeast chorismate mutase is regulated by tyrosine as feedback inhibitor and tryptophan as crosspathway activator. The monomer consists of a catalytic and a regulatory domain covalently linked by the loop L220s (212–226), which functions as a molecular hinge. Two monomers form the active dimeric enzyme stabilized by hydrophobic interactions in the vicinity of loop L220s. The role of loop L220s and its environment for enzyme regulation, dimerization, and stability was analyzed. Substitution of yeast loop L220s in place of the homologous loop from the corresponding and similarly regulated Aspergillus enzyme (and the reverse substitution) changed tyrosine inhibition to activation. Yeast loop L220s substituted into the Aspergillus enzyme resulted in a tryptophan-inhibitable enzyme. Monomeric yeast chorismate mutases could be generated by substituting two hydrophobic residues in and near the hinge region. The resulting Thr-212→Asp–Phe-28→Asp enzyme was as stable as wild type, but lost allosteric regulation and showed reduced catalytic activity. These results underline the crucial role of this molecular hinge for inhibition, activation, quaternary structure, and stability of yeast chorismate mutase. PMID:11997452
NASA Technical Reports Server (NTRS)
Murray, Harry E.; Erwin, Mary A.
1945-01-01
The results of a theoretical analysis of the hinge-moment characteristics of various sealed-internal-balance arrangements for control surfaces are presented. The analysis considered overhands sealed to various types of wing structure by flexible seals spanning gaps of various widths or sealed to the wing structure by a flexible system of linked plates. Leakage was not considered; the seal was assumed to extend the full spanwise length of the control surface. The effect of the developed width of the flexible seal and of the geometry of the structure to which the seal was anchored was investigated, as well as the effect of the gap width that is sealed. The results of the investigation indicated that the most nearly linear control-surface hinge-moment characteristics can probably be obtained from a flexible seal over a narrow gap (about 0.1 of the overhang chord), which is so installed that the motion of the seal is restricted to a region behind the point of attachment of the seal to the wing structure. Control-surface hinge moments that tend to be high at large deflections and low or overbalanced at small deflections will result if a very narrow seal is used.
Flectofold—a biomimetic compliant shading device for complex free form facades
NASA Astrophysics Data System (ADS)
Körner, A.; Born, L.; Mader, A.; Sachse, R.; Saffarian, S.; Westermeier, A. S.; Poppinga, S.; Bischoff, M.; Gresser, G. T.; Milwich, M.; Speck, T.; Knippers, J.
2018-01-01
Smart and adaptive outer façade shading systems are of high interest in modern architecture. For long lasting and reliable systems, the abandonment of hinges which often fail due to mechanical wear during repetitive use is of particular importance. Drawing inspiration from the hinge-less motion of the underwater snap-trap of the carnivorous waterwheel plant (Aldrovanda vesiculosa), the compliant façade shading device Flectofold was developed. Based on computational simulations of the biological role-model’s elastic and reversible motion, the actuation principle of the plant can be identified. The enclosed geometric motion principle is abstracted into a simplified curved-line folding geometry with distinct flexible hinge-zones. The kinematic behaviour is translated into a quantitative kinetic model, using finite element simulation which allows the detailed analyses of the influence of geometric parameters such as curved-fold line radius and various pneumatically driven actuation principles on the motion behaviour, stress concentrations within the hinge-zones, and actuation forces. The information regarding geometric relations and material gradients gained from those computational models are then used to develop novel material combinations for glass fibre reinforced plastics which enabled the fabrication of physical prototypes of the compliant façade shading device Flectofold.
Elasto-Capillary Folding Using Stop-Programmable Hinges Fabricated by 3D Micro-Machining
Legrain, Antoine; Berenschot, Erwin J. W.; Tas, Niels R.; Abelmann, Leon
2015-01-01
We show elasto-capillary folding of silicon nitride objects with accurate folding angles between flaps of (70.6 ± 0.1)° and demonstrate the feasibility of such accurate micro-assembly with a final folding angle of 90°. The folding angle is defined by stop-programmable hinges that are fabricated starting from silicon molds employing accurate three-dimensional corner lithography. This nano-patterning method exploits the conformal deposition and the subsequent timed isotropic etching of a thin film in a 3D shaped silicon template. The technique leaves a residue of the thin film in sharp concave corners which can be used as an inversion mask in subsequent steps. Hinges designed to stop the folding at 70.6° were fabricated batchwise by machining the V-grooves obtained by KOH etching in (110) silicon wafers; 90° stop-programmable hinges were obtained starting from silicon molds obtained by dry etching on (100) wafers. The presented technique has potential to achieve any folding angle and opens a new route towards creating structures with increased complexity, which will ultimately lead to a novel method for device fabrication. PMID:25992886
NASA Astrophysics Data System (ADS)
Tan, Chee Ghuan; Chia, Wei Ting; Majid, Taksiah A.; Nazri, Fadzli Mohamed; Adiyanto, Mohd Irwan
2017-10-01
On 5th June 2015, a moderate earthquake with Mw 5.9 hit Ranau, resulted in damages of the existing non-seismically designed buildings, such that 61 buildings, including mosques, schools, hospitals and Ranau police headquarters were suffered from different level structural damages. Soft storey irregularity is one of the main reasons of the building damage. This study is to investigate the soft-story effect on the propagation path of plastic hinges RC building under seismic excitation. The plastic hinges formation and seismic performance of five moment resisting RC frames with different infill configurations are studied. The seismic performance of building is evaluated by Incremental Dynamic Analysis (IDA). Open ground soft storey structure shows the lowest seismic resistance, collapses at 0.55g pga. The maximum interstorey drift ratio (IDRmax) in soft storey buildings ranging from 0.53% to 2.96% which are far greater than bare frame ranging from 0.095% to 0.69%. The presence of infill walls creates stiffer upper stories causing moments concentrate at the soft storey, resulting the path of plastic hinge propagation is dominant at the soft storey columns. Hence, the buildings with soft storey are very susceptible under earthquake load.
Magnetic Actuation of Self-Assembled DNA Hinges
NASA Astrophysics Data System (ADS)
Lauback, S.; Mattioli, K.; Armstrong, M.; Miller, C.; Pease, C.; Castro, C.; Sooryakumar, R.
DNA nanotechnology offers a broad range of applications spanning from the creation of nanoscale devices, motors and nanoparticle templates to the development of precise drug delivery systems. Central to advancing this technology is the ability to actuate or reconfigure structures in real time, which is currently achieved primarily by DNA strand displacement yielding slow actuation times (about 1-10min). Here we exploit superparamagnetic beads to magnetically actuate DNA structures which also provides a system to measure forces associated with molecular interactions. DNA nanodevices are folded using DNA origami, whereby a long single-stranded DNA is folded into a precise compact geometry using hundreds of short oligonucleotides. Our DNA nanodevice is a nanohinge from which rod shaped DNA nanostructures are polymerized into micron-scale filaments forming handles for actuation. By functionalizing one arm of the hinge and the filament ends, the hinge can be attached to a surface while still allowing an arm to rotate and the filaments can be labeled with magnetic beads enabling the hinge to be actuated almost instantaneously by external magnetic fields. These results lay the groundwork to establish real-time manipulation and direct force application of DNA constructs.
Liu, Zhaoqun; Zhou, Zhi; Wang, Lingling; Song, Xiaorui; Chen, Hao; Wang, Weilin; Liu, Rui; Wang, Mengqiang; Wang, Hao; Song, Linsheng
2015-08-01
Enkephalinergic neuroendocrine-immune regulatory system is one of the most important neuroendocrine-immune systems in both vertebrates and invertebrates for its significant role in the immune regulation. In the present study, the early onset of enkephalinergic nervous system and its immunomodulation on the developing immune system during the ontogenesis of oyster Crassostrea gigas were investigated to illustrate the function of neural regulation on the innate immune system in oyster larvae. [Met(5)]-enkephalin (Met-ENK) was firstly observed on the marginal of the dorsal half of D-hinged larvae. Six immune-related molecules, including four PRRs (CgCTL-1, CgCTL-2, CgCTL-4, CgNatterin-3) and two immune effectors (CgTNF-1 and CgEcSOD) were detected in the early developmental stages of trochophore, D-hinged and umbo larvae of oyster. After incubated with [Met(5)]-enkephalin, the mRNA expression level of all the PRRs changed significantly (p < 0.05). In trochophore larvae, the expression level of CgNatterin-3 decreased dramatically (p < 0.05) at 6 h, and the expression level of CgCTL-4 was significantly down-regulated at 3 h and 6 h (p < 0.05), respectively. In D-hinged and umbo larvae, only CgCTL-1 was significantly down-regulated and the differences were significant at 3 h and 6 h (p < 0.05), while the expression level of CgCTL-2 and CgCTL-4 increased significantly at 3 h after treatment (p < 0.05). Moreover, the expression levels of immune effectors were up-regulated significantly at 3 h and 6 h in trochophore larvae (p < 0.05). The expression level of CgTNF-1 in both blank and experiment groups was up-regulated but there was no significant difference in D-hinged larvae stage. On the contrary, the expression level of CgEcSOD in D-hinged larvae decreased dramatically at 3 h and 6 h after [Met(5)]-enkephalin incubation (p < 0.05). In umbo larvae, the expression level of CgTNF-1 and CgEcSOD in the experiment group increased significantly at 6 h after [Met(5)]-enkephalin treatment (p < 0.05), while no significant difference was found in the blank group. In addition, the anti-bacterial activities of the total protein extract from trochophore, D-hinged and umbo larvae increased significantly (p < 0.05) at both 3 h and 6 h after [Met(5)]-enkephalin incubation compared to that in the blank group, and PO activities of both D-hinged and umbo larvae total protein extract increased significantly (p < 0.05) while no significant difference was observed in trochophore larvae. The PO activities of the total protein extract in all the experiment groups decreased after the treatment with [Met(5)]-enkephalin for 6 h, but no significant difference was observed when compared to the blank group. Furthermore, after incubation for 6 h, the concentration of both CgTNF-1 and CgIL17-5 increased dramatically compared to that in the blank group (p < 0.05). These results together indicated that the enkephalinergic nervous system of oyster was firstly appeared in D-hinged larvae, while the primitive immune defense system existed in the region of prototroch in trochophore larvae and developed maturely after D-hinged larvae. The developing immune system could be regulated by the neurotransmitter [Met(5)]-enkephalin released by the neuroendocrine system in oyster C. gigas. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rhee, John M; Register, Bradley; Hamasaki, Takahiko; Franklin, Betty
2011-01-01
Prospective clinical series. To evaluate the ability of plate-only laminoplasty to achieve stable laminar arch reconstruction and to determine the rate and time course with which bony healing occurs in such constructs. Reconstruction of a stable laminar arch with sufficient room for the decompressed spinal cord is a desired goal when performing cervical laminoplasty for myelopathy. Traditional forms of laminoplasty fixation, such as sutures, bone struts, and ceramic spacers, may be associated with complications including loss of fixation, dislodgement with neurologic compromise, and premature laminoplasty closure. Plates, in contrast, provide more rigid fixation. Plate-only laminoplasty is gaining popularity as a method of laminoplasty fixation, but there is little data on its effectiveness. Fifty-four patients who underwent open door laminoplasty for cervical myelopathy and had available postoperative computed tomography (CT) scans formed the basis of this study. In all cases, a 4-mm round burr was used to create the hinge at the junction of the lateral mass and lamina by completely removing the dorsal cortex and thinning the ventral cortex until a greenstick deformation of the hinge could be produced. Laminoplasty plates were used as the sole method of fixation. No supplemental bone graft struts were used on the plated side, and the hinge side was not bone grafted. Axial CT scans obtained at 3, 6, and 12 months postoperatively were assessed for plate complications and bony healing of the hinge. No plate failures, dislodgements, or premature closures occurred in any of the levels at any time postoperatively. Computed tomography scan review demonstrated that 55% of levels were healed at 3 months, 77% at 6 months, and 93% at 12 months. At each timepoint, C6 and C7 had the highest hinge healing rates. Laminar screw backout was seen in 5/217 (2.3%) of levels, but was not associated with plate dislodgement, laminoplasty closure, or neurologic consequences, and did not occur in any case in which 2 laminar screws had been placed. Plate-only laminoplasty provided stable reconstruction of an expanded laminar arch with no failures, dislodgements, adverse neurologic consequences, or premature closures in 217 levels. Ninety-three percent of hinges demonstrated radiographic union at 12 months, and even those that did not heal by CT scan criteria maintained patent expansion of the spinal canal without adverse neurologic consequences. Supplemental bone graft does not appear necessary when plated laminoplasty is performed.
Design and Manufacture of a Highly Reliable, Miniaturized and Low Mass Shutter Mechanism
NASA Technical Reports Server (NTRS)
Manhart, M.; Zeh, T.; Preibler, G.; Hurni, A.; Walter, I.; Helbert, J.; Hiesinger, H.
2010-01-01
This paper describes the development, manufacturing and testing of a lightweight shutter mechanism made of titanium for the MERTIS Instrument. MERTIS is a thermal infrared imaging spectrometer onboard ESA's future BepiColombo mission to Mercury. The mechanism is built as a parallelogram arrangement of flexible hinges, actuated by a voice coil. In a first test run, it was shown that the selected EDM processing led to the generation of titanium oxides and an oxygen-enriched surface layer on the substrate (so called alpha-case layer). In the revised version of the shutter, it was possible to manufacture the complex geometry by micro-milling and an adjacent pickling procedure. The adequacy of this approach was verified by lifetime and vibration testing.
Pittet, Olivier; Demartines, Nicolas; Hahnloser, Dieter
2013-07-01
Acute anal pain is a common proctological problem. A detailed history together with the clinical examination are crucial for the diagnosis. An acute perianal vein thrombosis can be successfully excised within the first 72 hours. Acute anal fissures are best treated conservatively using stool regulation and topical medications reducing the sphincter spasm. A chronic anal fissure needs surgery. Perianal abscesses can very often be incised and drained in local anesthesia. Proctalgia fugax and the levator ani syndrome are exclusion diagnoses and are treated symptomatically.
ANMS-ESNM Position Paper and Consensus Guidelines On Biofeedback Therapy for Anorectal Disorders
Rao, Satish S.C.; Benninga, Marc A; Bharucha, Adil E; Chiarioni, Giuseppe; Di Lorenzo, Carlo; Whitehead, William E
2015-01-01
Anorectal disorders such as dyssynergic defecation, fecal incontinence, levator ani syndrome and solitary rectal ulcer syndrome are common, and affect both the adult and pediatric populations. Although they are treated with several treatment approaches, over the last two decades, biofeedback therapy using visual and verbal feedback techniques has emerged as an useful option. Because it is safe, it is commonly recommended. However, the clinical efficacy of biofeedback therapy in adults and children is not clearly known, and there is a lack of critical appraisal of the techniques used and the outcomes of biofeedback therapy for these disorders. The American Neurogastroenterology and Motility Society and the European Society of Neurogastroenterology and Motility convened a task force to examine the indications, study performance characteristics, methodologies used and the efficacy of biofeedback therapy, and to provide evidence-based recommendations. Based on the strength of evidence, biofeedback therapy is recommended for the short term and long term treatment of constipation with dyssynergic defecation (Level I, Grade A), and for the treatment of fecal incontinence (Level II, Grade B). Biofeedback therapy may be useful in the short-term treatment of Levator Ani Syndrome with dyssynergic defecation (Level II, Grade B), and solitary rectal ulcer syndrome with dyssynergic defecation (Level III, Grade C), but the evidence is fair. Evidence does not support the use of biofeedback for the treatment of childhood constipation (Level 1, Grade D). PMID:25828100
Kim, Min-Hee; Yoo, Won-Gyu
2015-06-05
According to a recent research, manual working with high levels of static contraction, repetitive loads, or extreme working postures involving the neck and shoulder muscles causes an increased risk of neck and shoulder musculoskeletal disorders. We investigated the effects of the forwardly worktable position on head and shoulder angles and shoulder muscle activity in manual material handling tasks. The forward head and shoulder angles and the activity of upper trapezius, levator scapulae, and middle deltoid muscle activities of 15 workers were measured during performing of manual material handling in two tasks that required different forward head and shoulder angles. The second manual material task required a significantly increased forward head and shoulder angle. The upper trapezius and levator scapulae muscle activity in second manual material task was increased significantly compared with first manual material task. The middle deltoid muscle activity in second manual material task was not significantly different compared with first manual material task. Based on this result, the forward head and shoulder angles while performing manual work need to be considered in selection of the forward distance of a worktable form the body. The high level contractions of the neck and shoulder muscles correlated with neck and shoulder pain. Therefore, the forward distance of a worktable can be an important factor in preventing neck and shoulder pain in manual material handling workers.
Cheng, Xu; Song, Lei; Lan, Min; Shi, Bing; Li, Jingtao
2018-01-01
Tibialis anterior (TA) muscle and other somite-derived limb muscles remain the prototype in skeletal muscle study. The majority of head muscles, however, develop from branchial arches and maintain a number of heterogeneities in comparison with their limb counterparts. Levator veli palatini (LVP) muscle is a deep-located head muscle responsible for breathing, swallowing and speech, and is central to cleft palate surgery, yet lacks morphological and molecular investigation. In the present study, multiscale in vivo analyses were performed to compare TA and LVP muscle in terms of their myofiber composition, in-situ stem cell population and augmentation potential. TA muscle was identified to be primarily composed of type 2B myofibers while LVP muscle primarily consisted of type 2A and 2X myofibers. In addition, LVP muscle maintained a higher percentage of centrally-nucleated myofibers and a greater population of satellite cells. Notably, TA and LVP muscle responded to exogenous Wnt7a stimulus in different ways. Three weeks after Wnt7a administration, TA muscle exhibited an increase in myofiber number and a decrease in myofiber size, while LVP muscle demonstrated no significant changes in myofiber number or myofiber size. These results suggested that LVP muscle exhibits obvious differences in comparison with TA muscle. Therefore, knowledge acquired from TA muscle studies requires further testing before being applied to LVP muscle.
Aerodynamic coefficients in generalized unsteady thin airfoil theory
NASA Technical Reports Server (NTRS)
Williams, M. H.
1980-01-01
Two cases are considered: (1) rigid body motion of an airfoil-flap combination consisting of vertical translation of given amplitude, rotation of given amplitude about a specified axis, and rotation of given amplitude of the control surface alone about its hinge; the upwash for this problem is defined mathematically; and (2) sinusoidal gust of given amplitude and wave number, for which the upwash is defined mathematically. Simple universal formulas are presented for the most important aerodynamic coefficients in unsteady thin airfoil theory. The lift and moment induced by a generalized gust are evaluated explicitly in terms of the gust wavelength. Similarly, in the control surface problem, the lift, moment, and hinge moments are given as explicit algebraic functions of hinge location. These results can be used together with any of the standard numerical inversion routines for the elementary loads (pitch and heave).
Attitude dynamics simulation subroutines for systems of hinge-connected rigid bodies
NASA Technical Reports Server (NTRS)
Fleischer, G. E.; Likins, P. W.
1974-01-01
Several computer subroutines are designed to provide the solution to minimum-dimension sets of discrete-coordinate equations of motion for systems consisting of an arbitrary number of hinge-connected rigid bodies assembled in a tree topology. In particular, these routines may be applied to: (1) the case of completely unrestricted hinge rotations, (2) the totally linearized case (all system rotations are small), and (3) the mixed, or partially linearized, case. The use of the programs in each case is demonstrated using a five-body spacecraft and attitude control system configuration. The ability of the subroutines to accommodate prescribed motions of system bodies is also demonstrated. Complete listings and user instructions are included for these routines (written in FORTRAN V) which are intended as multi- and general-purpose tools in the simulation of spacecraft and other complex electromechanical systems.
Self-folding micropatterned polymeric containers.
Azam, Anum; Laflin, Kate E; Jamal, Mustapha; Fernandes, Rohan; Gracias, David H
2011-02-01
We demonstrate self-folding of precisely patterned, optically transparent, all-polymeric containers and describe their utility in mammalian cell and microorganism encapsulation and culture. The polyhedral containers, with SU-8 faces and biodegradable polycaprolactone (PCL) hinges, spontaneously assembled on heating. Self-folding was driven by a minimization of surface area of the liquefying PCL hinges within lithographically patterned two-dimensional (2D) templates. The strategy allowed for the fabrication of containers with variable polyhedral shapes, sizes and precisely defined porosities in all three dimensions. We provide proof-of-concept for the use of these polymeric containers as encapsulants for beads, chemicals, mammalian cells and bacteria. We also compare accelerated hinge degradation rates in alkaline solutions of varying pH. These optically transparent containers resemble three-dimensional (3D) micro-Petri dishes and can be utilized to sustain, monitor and deliver living biological components.
Influence of tectonic folding on rockfall susceptibility, American Fork Canyon, Utah, USA
Coe, J.A.; Harp, E.L.
2007-01-01
We examine rockfall susceptibility of folded strata in the Sevier fold-thrust belt exposed in American Fork Canyon in north-central Utah. Large-scale geologic mapping, talus production data, rock-mass-quality measurements, and historical rockfall data indicate that rockfall susceptibility is correlated with limb dip and curvature of the folded, cliff-forming Mississippian limestones. On fold limbs, rockfall susceptibility increases as dip increases. This relation is controlled by several factors, including an increase in adverse dip conditions and apertures of discontinuities, and shearing by flexural slip during folding that has reduced the friction angles of discontinuities by smoothing surface asperities. Susceptibility is greater in fold hinge zones than on adjacent limbs primarily because there are greater numbers of discontinuities in hinge zones. We speculate that susceptibility increases in hinge zones as fold curvature becomes tighter.
Tilting table for ergometer and for other biomedical devices
NASA Technical Reports Server (NTRS)
Gause, R. L.; Spier, R. A. (Inventor)
1973-01-01
The apparatus is for testing the human body in a variety of positions, ranging from the vertical to the supine, while exercising on an ergometer; and can also be used for angular positioning of other biomedical devices. It includes a floor plate and a hinged plate upon which to fix the ergometer, a back rest and a head rest attached at right angles to said hinged plate and behind the seat of the ergometer, dual hydraulic cylinders for raising and lowering the hinged plate through 90 deg by means of a self contained hydraulic system, with valve means for control and positive stops on the apparatus to prevent over travel. Tests can be made with the subject positioned on the seat of the ergometer, through the various angles, with a substantially normal body attitude relative to the seat and ergometer.
Facial Contouring by Targeted Restoration of Facial Fat Compartment Volume: The Midface.
Wang, Wenjin; Xie, Yun; Huang, Ru-Lin; Zhou, Jia; Tanja, Herrler; Zhao, Peijuan; Cheng, Chen; Zhou, Sizheng; Pu, Lee L Q; Li, Qingfeng
2017-03-01
Recent anatomical findings have suggested that facial fat distribution is complex and changes with age. Here, the authors developed a grafting technique based on the physiologic distribution and volume changes of facial fat compartments to achieve a youthful and natural-appearing face. Forty cadaveric hemifaces were used for the dissection of fat compartments and neurovascular structures in the midface area. Seventy-eight patients were treated for cheek atrophy using the authors' targeted restoration of midface fat compartment volume. The outcome was evaluated by a two-dimensional assessment, malar lipoatrophy assessment, and a satisfaction survey. The medial and lateral parts of the deep medial cheek fat compartment were separated by a septum arising from the lateral border of the levator anguli oris muscle. The angular vein traveled between the deep medial cheek fat compartment and the buccal fat pad, 12 mm from the maxilla. A total volume of 29.3 ml of fat was grafted per cheek for each patient. A 12-month follow-up revealed an average volume augmentation rate of 27.1 percent. Pleasing and elevated anterior projection of the cheek and ameliorated nasolabial groove were still obvious by 12 months after the procedure. In total, 95.2 percent of the patients were satisfied with their results. The present study provides the anatomical and clinical basis for the concept of compartmentally based fat grafting. It allows for the restoration of facial fat volume close to the physiologic state. With this procedure, a natural and youthful facial contour could be rebuilt with a high satisfaction rate. Therapeutic, IV.
NASA Technical Reports Server (NTRS)
Foley, Robert J.; Pendergraft, Odis C., Jr.
1991-01-01
A static (wind-off) test was conducted in the Static Test Facility of the 16-ft transonic tunnel to determine the performance and turning effectiveness of post-exit yaw vanes installed on two-dimensional convergent-divergent nozzles. One nozzle design that was previously tested was used as a baseline, simulating dry power and afterburning power nozzles at both 0 and 20 degree pitch vectoring conditions. Vanes were installed on these four nozzle configurations to study the effects of vane deflection angle, longitudinal and lateral location, size, and camber. All vanes were hinged at the nozzle sidewall exit, and in addition, some were also hinged at the vane quarter chord (double-hinged). The vane concepts tested generally produced yaw thrust vectoring angles much less than the geometric vane angles, for (up to 8 percent) resultant thrust losses. When the nozzles were pitch vectored, yawing effectiveness decreased as the vanes were moved downstream. Thrust penalties and yawing effectiveness both decreased rapidly as the vanes were moved outboard (laterally). Vane length and height changes increased yawing effectiveness and thrust ratio losses, while using vane camber, and double-hinged vanes increased resultant yaw angles by 50 to 100 percent.
NASA Technical Reports Server (NTRS)
Olney, Candida D.; Hillebrandt, Heather; Reichenbach, Eric Y.
2000-01-01
A limited evaluation of the F/A-18 baseline loads model was performed on the Systems Research Aircraft at NASA Dryden Flight Research Center (Edwards, California). Boeing developed the F/A-18 loads model using a linear aeroelastic analysis in conjunction with a flight simulator to determine loads at discrete locations on the aircraft. This experiment was designed so that analysis of doublets could be used to establish aircraft aerodynamic and loads response at 20 flight conditions. Instrumentation on the right outboard leading edge flap, left aileron, and left stabilator measured the hinge moment so that comparisons could be made between in-flight-measured hinge moments and loads model-predicted values at these locations. Comparisons showed that the difference between the loads model-predicted and in-flight-measured hinge moments was up to 130 percent of the flight limit load. A stepwise regression technique was used to determine new loads derivatives. These derivatives were placed in the loads model, which reduced the error to within 10 percent of the flight limit load. This paper discusses the flight test methodology, a process for determining loads coefficients, and the direct comparisons of predicted and measured hinge moments and loads coefficients.
NASA Astrophysics Data System (ADS)
Pathak, Arup Kumar
2018-05-01
Despite the knowledge that the influenza protein, hemagglutinin, undergoes a large conformational change at low pH during the process of fusion with the host cell, its molecular mechanism remains elusive. The present constant pH molecular dynamics (CpHMD) study identifies the residues responsible for large conformational change in acidic condition. Based on the pKa calculations, it is predicted that His-106 is much more responsible for the large conformational change than any other residues in the hinge region of hemagglutinin protein. Potential of mean force profile from well-tempered meta-dynamics (WT-MtD) simulation is also generated along the folding pathway by considering radius of gyration (R gyr) as a collective variable (CV). It is very clear from the present WT-MtD study, that the initial bending starts at that hinge region, which may trigger other conformational changes. Both the protein–protein and protein–water HB time correlation functions are monitored along the folding pathway. The protein–protein (full or hinge region) HB time correlation functions are always found to be stronger than those of the protein–water time correlation functions. The dynamical balance between protein–protein and protein–water HB interactions favors the stabilization of the folded state.
Knightsat Flight Design Review
2007-08-03
spring loaded hinges were obtained from McMaster under part number 15205A42. The fasteners used to attach each shutter to its corresponding hinge were... Coefficient of thermal expansion) is fairly well matched to the cell’s germanium substrate. Copper is not a good choice since it expands and contracts...Temperature: K Ground Station Transmission Line Temp.: 290 K Ground Station Sky Temperature: 450 K G.S. Transmission Line Coefficient : 0.7943 Ground Station
NASA Technical Reports Server (NTRS)
Tang, M. H.; Sefic, W. J.; Sheldon, R. G.
1978-01-01
Concurrent strain gage and pressure transducer measured flight loads on a lifting reentry vehicle are compared and correlated with wind tunnel-predicted loads. Subsonic, transonic, and supersonic aerodynamic loads are presented for the left fin and control surfaces of the X-24B lifting reentry vehicle. Typical left fin pressure distributions are shown. The effects of variations in angle of attack, angle of sideslip, and Mach number on the left fin loads and rudder hinge moments are presented in coefficient form. Also presented are the effects of variations in angle of attack and Mach number on the upper flap, lower flap, and aileron hinge-moment coefficients. The effects of variations in lower flap hinge moments due to changes in lower flap deflection and Mach number are presented in terms of coefficient slopes.
Coleman, Clint; Kurth, William T.
1994-06-14
A wind turbine has a rotor with at least one blade which has an aileron which is adjusted by an actuator. A hinge has two portions, one for mounting a stationary hinge arm to the blade, the other for coupling to the aileron actuator. Several types of hinges can be used, along with different actuators. The aileron is designed so that it has a constant chord with a number of identical sub-assemblies. The leading edge of the aileron has at least one curved portion so that the aileron does not vent over a certain range of angles, but vents if the position is outside the range. A cyclic actuator can be mounted to the aileron to adjust the position periodically. Generally, the aileron will be adjusted over a range related to the rotational position of the blade. A method for operating the cyclic assembly is also described.
Folding Elastic Thermal Surface - FETS
NASA Technical Reports Server (NTRS)
Urquiza, Eugenio; Zhang, Burt X.; Thelen, Michael P.; Rodriquez, Jose I.; Pellegrino, Sergio
2013-01-01
The FETS is a light and compact thermal surface (sun shade, IR thermal shield, cover, and/or deployable radiator) that is mounted on a set of offset tape-spring hinges. The thermal surface is constrained during launch and activated in space by a thermomechanical latch such as a wax actuator. An application-specific embodiment of this technology developed for the MATMOS (Mars Atmospheric Trace Molecule Occultation Spectrometer) project serves as a deployable cover and thermal shield for its passive cooler. The FETS fits compactly against the instrument within the constrained launch envelope, and then unfolds into a larger area once in space. In this application, the FETS protects the passive cooler from thermal damage and contamination during ground operations, launch, and during orbit insertion. Once unfolded or deployed, the FETS serves as a heat shield, intercepting parasitic heat loads by blocking the passive cooler s view of the warm spacecraft. The technology significantly enhances the capabilities of instruments requiring either active or passive cooling of optical detectors. This can be particularly important for instruments where performance is limited by the available radiator area. Examples would be IR optical instruments on CubeSATs or those launched as hosted payloads because radiator area is limited and views are often undesirable. As a deployable radiator, the panels making up the FETS are linked thermally by thermal straps and heat pipes; the structural support and deployment energy is provided using tape-spring hinges. The FETS is a novel combination of existing technologies. Prior art for deployable heat shields uses rotating hinges that typically must be lubricated to avoid cold welding or static friction. By using tape-spring hinges, the FETS avoids the need for lubricants by avoiding friction altogether. This also eliminates the potential for contamination of nearby cooled optics by outgassing lubricants. Furthermore, the tape-spring design of the FETS is also self-locking so the panels stay in a rigid and extended configuration after deployment. This unexpected benefit makes the tape-spring hinge design of the FETS a light, simple, reliable, compact, non-outgassing hinge, spring, and latch. While tape-spring hinges are not novel, they have never been used to deploy passive unfolding thermal surfaces (radiator panels, covers, sun shades, or IR thermal shields). Furthermore, because this technology is compact, it has minimal impact on the launch envelope and mass specifications. FETS enhances the performance of hosted payload instruments where the science data is limited by dark noise. Incorporating FETS into a thermal control system increases radiator area, which lowers the optical detector temperature. This results in higher SNR (signal-to-noise ratio) and improved science data.
2018-03-21
Congenital Fibrosis of Extraocular Muscles; Duane Retraction Syndrome; Duane Radial Ray Syndrome; Mobius Syndrome; Brown Syndrome; Marcus Gunn Syndrome; Strabismus Congenital; Horizontal Gaze Palsy; Horizontal Gaze Palsy With Progressive Scoliosis; Facial Palsy; Facial Paresis, Hereditary, Congenital; Third Nerve Palsy; Fourth Nerve Palsy; Sixth Nerve Palsy; Synkinesis; Ocular Motility Disorders; Levator-Medial Rectus Synkinesis; Athabaskan Brainstem Dysgenesis; Tongue Paralysis; Ninth Nerve Disorder; Fifth Nerve Palsy; Seventh Nerve Palsy; Eleventh Nerve Disorder; Twelfth Nerve Disorder; Vagus Nerve Paralysis; Moebius Sequence
A Study to Determine the Feasibility of Implementing Same-Day Surgery at Brooke Army Medical Center
1989-02-01
RECTAL MASSAGE (FOR LEVATOR SPASM) 9994 PROSTATIC MASSAGE z 9995 STRETCHING OF FORESKIN ci 9996 COLLECTION OF SPERM FOR ARTIFICIAL INSEMINATION > 9997...the same day. It can be performed in hospitals, in hospital satellites , in buildings adjacent to or near hospitals, or in independently operated...hospital’s structure but has m independent operating room recovery areas; 0 0 C 0 (3) Satellite --The program is based in a separate facility, m located off
Unattractive infant faces elicit negative affect from adults
Schein, Stevie S.; Langlois, Judith H.
2015-01-01
We examined the relationship between infant attractiveness and adult affect by investigating whether differing levels of infant facial attractiveness elicit facial muscle movement correlated with positive and negative affect from adults (N = 87) using electromyography. Unattractive infant faces evoked significantly more corrugator supercilii and levator labii superioris movement (physiological correlates of negative affect) than attractive infant faces. These results suggest that unattractive infants may be at risk for negative affective responses from adults, though the relationship between those responses and caregiving behavior remains elusive. PMID:25658199
Coccygodynia - pathogenesis, diagnostics and therapy. Review of the writing.
Dampc, Bogumiła; Słowiński, Krzysztof
2017-08-31
Coccygodynia is a problem with a small percentage (1%) of the population suffering from musculoskeletal disorders. This pain is often associated with trauma, falling on the tailbone, long cycling, or by women after childbirth. The reason for the described problem can be the actual morphological changes. Idiopathic coccygodynia causes therapeutic difficulties to specialists of many fields. Unsatisfactory treatment, including coccygectomy tends to seek new solutions. They belong to them techniques exploited in the manual therapy which in their spectrum hold: direct techniques - per rectum as well as indirect techniques taking into account distant structures of the motor organ, remaining in dense interactions with the coccygeal part. Idiopathic coccygodynia is a result perhaps from exaggerated tension the muscle of the levator ani, coccygeus and gluteus maximus as well as from irritating soft tissue structures surrounding the coccyx: of sacrococcygeum, sacrospinale, and sacrotuberale ligament. Unfortunately we can't see them in objective examinations so as: the RTG, MR or TK, therefore constitute the both diagnostic and therapeutic problem. For describing the problem a writing of the object was used both from the field of the surgery and of manual therapy. Detailed and multifaceted knowledge about causes of the described problem allows more accurately to categorize the patient to the appropriate group and helps to select the best procedure of treatment.
NASA Technical Reports Server (NTRS)
Nichols, M. E.
1976-01-01
Test procedures, history, and data from the wind tunnel test are presented. Aero-loads were investigated on the updated configuration-5 space shuttle launch vehicle at Mach numbers from 0.600 to 1.205. Six-component vehicle forces and moments, base and sting-cavity pressures, elevon hinge moments, wing-root bending and torsion moments, and normal shear force data were obtained. Full simulation of updated vehicle protuberances and attach hardware was employed. Various elevon deflection angles were tested with two different forward orbiter-to-external-tank attach-strut configurations. The entire model was supported by means of a balance mounted in the orbiter through its base and suspended from a sting.
The rock components and structures of Archean greenstone belts: An overview
NASA Technical Reports Server (NTRS)
Lowe, D. R.; Byerly, G. R.
1986-01-01
Knowledge of the character and evolution of the Earth's early crust is derived from the studies of the rocks and structures in Archean greenstone belts. Ability to resolve the petrologic, sedimentological and structural histories of greenstone belts, however, hinges first on an ability to apply the concepts and procedures of classical stratigraphy. Unfortunately, early Precambrian greenstone terrains present particular problems to stratigraphic analysis. Many current controversies of greenstone belt petrogenesis, sedimentology, tectonics and evolution arise more from an inability to develop a clear stratigraphic picture of the belts than from ambiguities in interpretation. Four particular stratigraphic problems that afflict studies of Archean greenstone belts are considered: determination of facing directions, correlation of lithologic units, identification of primary lithologies and discrimination of stratigraphic versus structural contacts.
A PBOM configuration and management method based on templates
NASA Astrophysics Data System (ADS)
Guo, Kai; Qiao, Lihong; Qie, Yifan
2018-03-01
The design of Process Bill of Materials (PBOM) holds a hinge position in the process of product development. The requirements of PBOM configuration design and management for complex products are analysed in this paper, which include the reuse technique of configuration procedure and urgent management need of huge quantity of product family PBOM data. Based on the analysis, the function framework of PBOM configuration and management has been established. Configuration templates and modules are defined in the framework to support the customization and the reuse of configuration process. The configuration process of a detection sensor PBOM is shown as an illustration case in the end. The rapid and agile PBOM configuration and management can be achieved utilizing template-based method, which has a vital significance to improve the development efficiency for complex products.
Glavinović, Martin; Qi, Feng; Katsenis, Athanassios D.
2016-01-01
We develop an associative synthesis of metal–organic materials that combines solid-state metal oxidation and coordination-driven self-assembly into a one-step, waste-free transformation. The methodology hinges on the unique reactivity of ortho-quinones, which we introduce as versatile oxidants for mechanochemical synthesis. Our strategy opens a previously unexplored route to paramagnetic metal–organic materials from elementary metals. PMID:28791114
Computational Modeling of Shape Memory Polymer Origami that Responds to Light
NASA Astrophysics Data System (ADS)
Mailen, Russell William
Shape memory polymers (SMPs) transform in response to external stimuli, such as infrared (IR) light. Although SMPs have many applications, this investigation focuses on their use as actuators in self-folding origami structures. Ink patterned on the surface of the SMP sheet absorbs thermal energy from the IR light, which produces localized heating. The material shrinks wherever the activation temperature is exceeded and can produce out-of-plane deformation. The time and temperature dependent response of these SMPs provides unique opportunities for developing complex three-dimensional (3D) structures from initially flat sheets through self-folding origami, but the application of this technique requires predicting accurately the final folded or deformed shape. Furthermore, current computational approaches for SMPs do not fully couple the thermo-mechanical response of the material. Hence, a proposed nonlinear, 3D, thermo-viscoelastic finite element framework was formulated to predict deformed shapes for different self-folding systems and compared to experimental results for self-folding origami structures. A detailed understanding of the shape memory response and the effect of controllable design parameters, such as the ink pattern, pre-strain conditions, and applied thermal and mechanical fields, allows for a predictive understanding and design of functional, 3D structures. The proposed modeling framework was used to obtain a fundamental understanding of the thermo-mechanical behavior of SMPs and the impact of the material behavior on hinged self-folding. These predictions indicated how the thermal and mechanical conditions during pre-strain significantly affect the shrinking and folding response of the SMP. Additionally, the externally applied thermal loads significantly influenced the folding rate and maximum bending angle. The computational framework was also adapted to understand the effects of fully coupling the thermal and mechanical response of the material. This updated framework accounted for external heat sources, such as ambient temperature and incident surface heat flux, as well as internal temperature changes due to conduction and viscous heat generation. Viscous heating during the pre-strain sequence affected the residual stresses after cooling due to accelerated viscoelastic relaxation. This resulted in a delayed shrinking and folding response. Other factors that affected the folding response include sheet thickness, hinge width, degree of pre-strain, and hinge temperature. The predicted results indicated that the maximum bending angle can be increased for a folded structure by increasing the hinge width, degree of pre-strain, and hinge surface temperature. Folding time can be reduced by decreasing the sheet thickness, increasing the hinge width, and increasing the hinge temperature. The coupled thermo-mechanical approach was also extended to investigate both curved and folded structures by varying the ink pattern and the substrate geometry. With this approach, two continuous curvature mechanisms were obtained. One was an indirect curvature mechanism which resulted from internal stresses that evolved from the shrinking of activated regions of the material relative to unactivated regions. The second was a direct curvature mechanism that resulted from ink distributed in gradients across the surface of the material. Furthermore, the effects of hinge orientation, proximity of multiple hinges, sheet aspect ratio, and axisymmetric ink patterns were characterized for other shapes, such as rectangles and discs. The findings of this investigation clearly indicate that this validated computational approach can be used to predict and understand the myriad mechanisms of self-folding origami structures. By varying the location of ink on the polymer surface and making changes to the substrate geometry, complex 3D structures can be obtained. The developed thermo-mechanical framework can be used to design optimized origami structures for biomedical devices, space telescopes, and functional, engineered origami devices.
T-Craft Seabase Ramp Loads Model Test Data Report
2010-12-01
INTRODUCTION 1 TEST CONDITION MATRIX 2 MODEL DESCRIPTIONS 9 LMSR Model 15 Ramp Models 17 MODEL TEST SETUP 18 Side-by-Side Hull Configuration 19... INTRODUCTION The Office of Naval Research (ONR) sponsored a multiple bodied seakeeping model test designed to investigate vessel motions and loads on the hinge...C. 3. Side-by-Side configuration 137 Ramp Load cell 1.88 27.49 -CG ft I ^ -Hinged Connection 3.00 from CL to jauge • oad ce LMSR
Engineering design, stress and thermal analysis, and documentation for SATS program
NASA Technical Reports Server (NTRS)
1973-01-01
An in-depth analysis and mechanical design of the solar array stowage and deployment arrangements for use in Small Applications Technology Satellite spacecraft is presented. Alternate approaches for the major elements of work are developed and evaluated. Elements include array stowage and deployment arrangements, the spacecraft and array behavior in the spacecraft despin mode, and the design of the main hinge and segment hinge assemblies. Feasibility calculations are performed and the preferred approach is identified.
Fiber Grating Moisture And Chemical Sensing System
Schipani, Claudia; Spano, Ennio; Dalle Crode, Domenico
2004-01-27
A vane for a stator of a variable-geometry turbine, in particular for aeronautical engines, has an airfoil profile and a pair of hinge portions, which are carried by the airfoil profile and enable the airfoil profile to be coupled to a support structure of the stator so as to be rotatable about an axis of adjustment; the vane also has internal channels that allow a flow of air to pass through in order to cool the hinge portions.
NASA Technical Reports Server (NTRS)
Baucom, R. M. (Inventor)
1983-01-01
An X-ray transparent and biological inert medical clip for treating aneurisms and the like is described. A graphite reinforced composite film is molded into a unitary structure having a pair of hourglass-like cavities hinged together with a pair of jaws for grasping the aneurism extending from the wall of one cavity. A silicone rubber pellet is disposed in the other cavity to exert a spring force through the hinge area to normally bias the jaws into contact with each other.
A Flight-Dynamic Helicopter Mathematical Model with a Single Flap-Lag- Torsion Main Rotor
1990-02-01
allows several hinge sequences and two offsets in the hinges. Quasi-steady Greenberg theory is used to calculate the blade-section aerodynamic forces...steady Greenberg model is used (ref. 3), Unsteady inflow effects are included using the three-state nonlinear Pitt/Peters dynamic inflow model (ref. 4...sectional aerodynamic model is based on quasi-steady Greenberg theory, which is a Theodorsen theory modified to account for lead-lag motions (refs. 3,14). The
Localised JAK/STAT Pathway Activation Is Required for Drosophila Wing Hinge Development
Johnstone, Kirsty; Wells, Richard E.; Strutt, David; Zeidler, Martin P.
2013-01-01
Extensive morphogenetic remodelling takes place during metamorphosis from a larval to an adult insect body plan. These changes are particularly intricate in the generation of the dipteran wing hinge, a complex structure that is derived from an apparently simple region of the wing imaginal disc. Using the characterisation of original outstretched alleles of the unpaired locus as a starting point, we demonstrate the role of JAK/STAT pathway signalling in the process of wing hinge development. We show that differences in JAK/STAT signalling within the proximal most of three lateral folds present in the wing imaginal disc is required for fold morphology and the subsequent differentiation of the first and second auxiliary sclerites as well as the posterior notal wing process. Changes in these domains are consistent with the established fate map of the wing disc. We show that outstretched wing posture phenotypes arise from the loss of a region of Unpaired expression in the proximal wing fold and demonstrate that this results in a decrease in JAK/STAT pathway activity. Finally we show that reduction of JAK/STAT pathway activity within the proximal wing fold is sufficient to phenocopy the outstretched phenotype. Taken together, we suggest that localised Unpaired expression and hence JAK/STAT pathway activity, is required for the morphogenesis of the adult wing hinge, providing new insights into the link between signal transduction pathways, patterning and development. PMID:23741461
Schierjott, Ronja A; Giurea, Alexander; Neuhaus, Hans-Joachim; Schwiesau, Jens; Pfaff, Andreas M; Utzschneider, Sandra; Tozzi, Gianluca; Grupp, Thomas M
2016-01-01
Carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) represents a promising alternative material for bushings in total knee replacements, after early clinical failures of polyethylene in this application. The objective of the present study was to evaluate the damage modes and the extent of damage observed on CFR-PEEK hinge mechanism articulation components after in vivo service in a rotating hinge knee (RHK) system and to compare the results with corresponding components subjected to in vitro wear tests. Key question was if there were any similarities or differences between in vivo and in vitro damage characteristics. Twelve retrieved RHK systems after an average of 34.9 months in vivo underwent wear damage analysis with focus on the four integrated CFR-PEEK components and distinction between different damage modes and classification with a scoring system. The analysis included visual examination, scanning electron microscopy, and energy dispersive X-ray spectroscopy, as well as surface roughness and profile measurements. The main wear damage modes were comparable between retrieved and in vitro specimens ( n = 3), whereby the size of affected area on the retrieved components showed a higher variation. Overall, the retrieved specimens seemed to be slightly heavier damaged which was probably attributable to the more complex loading and kinematic conditions in vivo.
How insect flight steering muscles work.
Hedenström, Anders
2014-03-01
Insights into how exactly a fly powers and controls flight have been hindered by the need to unpick the dynamic complexity of the muscles involved. The wingbeats of insects are driven by two antagonistic groups of power muscles and the force is funneled to the wing via a very complex hinge mechanism. The hinge consists of several hardened and articulated cuticle elements called sclerites. This articulation is controlled by a great number of small steering muscles, whose function has been studied by means of kinematics and muscle activity. The details and partly novel function of some of these steering muscles and their tendons have now been revealed in research published in this issue of PLOS Biology. The new study from Graham Taylor and colleagues applies time-resolved X-ray microtomography to obtain a three-dimensional view of the blowfly wingbeat. Asymmetric power output is achieved by differential wingbeat amplitude on the left and right wing, which is mediated by muscular control of the hinge elements to mechanically block the wing stroke and by absorption of work by steering muscles on one of the sides. This new approach permits visualization of the motion of the thorax, wing muscles, and the hinge mechanism. This very promising line of work will help to reveal the complete picture of the flight motor of a fly. It also holds great potential for novel bio-inspired designs of fly-like micro air vehicles.
On the Roles of Substrate Binding and Hinge Unfolding in Conformational Changes of Adenylate Kinase
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brokaw, Jason B.; Chu, Jhih-wei
2010-11-17
We characterized the conformational change of adenylate kinase (AK) between open and closed forms by conducting five all-atom molecular-dynamics simulations, each of 100 ns duration. Different initial structures and substrate binding configurations were used to probe the pathways of AK conformational change in explicit solvent, and no bias potential was applied. A complete closed-to-open and a partial open-to-closed transition were observed, demonstrating the direct impact of substrate-mediated interactions on shifting protein conformation. The sampled configurations suggest two possible pathways for connecting the open and closed structures of AK, affirming the prediction made based on available x-ray structures and earlier worksmore » of coarse-grained modeling. The trajectories of the all-atom molecular-dynamics simulations revealed the complexity of protein dynamics and the coupling between different domains during conformational change. Calculations of solvent density and density fluctuations surrounding AK did not show prominent variation during the transition between closed and open forms. Finally, we characterized the effects of local unfolding of an important hinge near Pro177 on the closed-to-open transition of AK and identified a novel mechanism by which hinge unfolding modulates protein conformational change. The local unfolding of Pro177 hinge induces alternative tertiary contacts that stabilize the closed structure and prevent the opening transition.« less
Loads Model Development and Analysis for the F/A-18 Active Aeroelastic Wing Airplane
NASA Technical Reports Server (NTRS)
Allen, Michael J.; Lizotte, Andrew M.; Dibley, Ryan P.; Clarke, Robert
2005-01-01
The Active Aeroelastic Wing airplane was successfully flight-tested in March 2005. During phase 1 of the two-phase program, an onboard excitation system provided independent control surface movements that were used to develop a loads model for the wing structure and wing control surfaces. The resulting loads model, which was used to develop the control laws for phase 2, is described. The loads model was developed from flight data through the use of a multiple linear regression technique. The loads model input consisted of aircraft states and control surface positions, in addition to nonlinear inputs that were calculated from flight-measured parameters. The loads model output for each wing consisted of wing-root bending moment and torque, wing-fold bending moment and torque, inboard and outboard leading-edge flap hinge moment, trailing-edge flap hinge moment, and aileron hinge moment. The development of the Active Aeroelastic Wing loads model is described, and the ability of the model to predict loads during phase 2 research maneuvers is demonstrated. Results show a good match to phase 2 flight data for all loads except inboard and outboard leading-edge flap hinge moments at certain flight conditions. The average load prediction errors for all loads at all flight conditions are 9.1 percent for maximum stick-deflection rolls, 4.4 percent for 5-g windup turns, and 7.7 percent for 4-g rolling pullouts.
Struik, T; Jaspers, J E N; Besselink, N J; van Roermund, P M; Plomp, S; Rudert, M J; Lafeber, F P J G; Mastbergen, S C
2017-11-01
Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.
Use of rapid prototyping drill template for the expansive open door laminoplasty: A cadaveric study.
Rong, Xin; Wang, Beiyu; Chen, Hua; Ding, Chen; Deng, Yuxiao; Ma, Lipeng; Ma, Yanzhao; Liu, Hao
2016-11-01
Trough preparation is a technically demanding yet critical procedure for successful expansive open door laminoplasty (EOLP), requiring both proper position and appropriate bone removal. We aimed to use the specific rapid prototyping drill template to achieve such requirement. The 3D model of the cadaveric cervical spine was reconstructed using the Mimics 17.0 and Geomagic Studio 12.0 software. The drilling template was designed in the 3-Matic software. The trough position was simulated at the medial margin of the facet joint. Two holders were designed on both sides. On the open side, the holder would just allow the drill penetrate the ventral cortex of the lamina. On the hinge side, the holder was designed to keep the ventral cortex of the lamina intact. One orthopedic resident performed the surgery using the rapid prototyping drill template on four cadavers (template group). A control group of four cadavers were operated upon without the use of the template. The deviation of the final trough position from the simulated trough position was 0.18mm±0.51mm in the template group. All the troughs in the template group and 40% of the troughs in the control group were at the medial side of the facet joint. The complete hinge fracture rate was 5% in the template group, significantly lower than that (55%) in the control group (P=0.01). The rapid prototyping drill template could help the surgeon accomplish proper trough position and appropriate bone removal in EOLP on the cadaveric cervical spine. Copyright © 2016 Elsevier B.V. All rights reserved.
Improved design of support for large aperture space lightweight mirror
NASA Astrophysics Data System (ADS)
Wang, Chao; Ruan, Ping; Liu, Qimin
2013-08-01
In order to design a kind of rational large aperture space mirror which can adapt to the space gravity and thermal environment, by taking the choice of material, the lightweight of the mirror and the design of support into account in detail, a double-deck structure with traditional flexible hinge was designed, then the analytical mathematical model of the mirror system was established. The design adopts six supports on back. in order to avoid the constraints, mirror is connected to three middle transition pieces through six flexible hinges, and then the three transition pieces are connected to support plate through another three flexible hinges. However, the initial structure is unable to reach the expected design target and needs to be made further adjustments. By improving and optimizing the original structure, a new type of flexible hinge in the shape of the letter A is designed finally. Compared with the traditional flexible hinge structure, the new structure is simpler and has less influence on the surface figure accuracy of mirror. By using the finite element analysis method, the static and dynamic characteristics as well as the thermal characteristics of the mirror system are analyzed. Analysis results show that the maximum PV value is 37 nm and the maximum RMS value is 10.4 nm when gravity load is applied. Furthermore, the maximum PV value is 46 nm and the maximum RMS value is 10.5 nm under the load case of gravity coupled with 4℃ uniform temperature rise. The results satisfy the index of optical design. The first order natural frequency of the mirror component is 130 Hz according to the conclusion obtained by modal analytical solution, so the mirror structure has high enough fundamental frequency. And, the structural strength can meet the demand under the overload and the random vibration environment respectively. It indicates that the mirror component structure has enough dynamic, static stiffness and thermal stability, meeting the design requirements.
Pelvic Floor Dynamics During High-Impact Athletic Activities: A Computational Modeling Study
Dias, Nicholas; Peng, Yun; Khavari, Rose; Nakib, Nissrine A.; Sweet, Robert M.; Timm, Gerald W.; Erdman, Arthur G.; Boone, Timothy B.
2017-01-01
Background Stress urinary incontinence is a significant problem in young female athletes, but the pathophysiology remains unclear because of the limited knowledge of the pelvic floor support function and limited capability of currently available assessment tools. The aim of our study is to develop an advanced computer modeling tool to better understand the dynamics of the internal pelvic floor during highly transient athletic activities. Methods Apelvic model was developed based on high-resolution MRI scans of a healthy nulliparous young female. A jump-landing process was simulated using realistic boundary conditions captured from jumping experiments. Hypothesized alterations of the function of pelvic floor muscles were simulated by weakening or strengthening the levator ani muscle stiffness at different levels. Intra-abdominal pressures and corresponding deformations of pelvic floor structures were monitored at different levels of weakness or enhancement. Findings Results show that pelvic floor deformations generated during a jump-landing process differed greatly from those seen in a Valsalva maneuver which is commonly used for diagnosis in clinic. The urethral mobility was only slightly influenced by the alterations of the levator ani muscle stiffness. Implications for risk factors and treatment strategies were also discussed. Interpretation Results suggest that clinical diagnosis should make allowances for observed differences in pelvic floor deformations between a Valsalva maneuver and a jump-landing process to ensure accuracy. Urethral hypermobility may be a less contributing factor than the intrinsic sphincteric closure system to the incontinence of young female athletes. PMID:27886590
Hur, Mi-Sun
2017-08-01
The aim of this study was to clarify the anatomical relationship of the procerus with the nose, especially focusing on the transverse part of the nasalis, the nasal ala, and the levator labii superioris alaeque nasi (LLSAN). The 53 faces from Korean cadavers were examined anatomically. The procerus originated from the superficial and deep layers in all specimens. Some fibers of the lateral part of the superficial layer extended to connect to the transverse part of the nasalis, while other such fibers extended to attach to the skin of the upper nasal ala in all specimens. The superficial and deep layers of the procerus merged and then intermingled with the frontalis. The anatomical relationship between the superficial layer of the procerus and the LLSAN was classified into the following two categories according to their connections. Some medial originating fibers of the LLSAN extended superomedially to blend in the area between the superficial layer of the procerus and the depressor supercilii (13.5%). And, some medial originating fibers of the LLSAN extended superomedially and then constituted the lateral portion of the superficial layer of the procerus (7.7%). This study has yielded crucial data for understanding the anatomical relationships and functions of the procerus in relation to the nose. They will be helpful when designing effective therapies involving botulinum toxin type A, performing various types of rhinoplasty and facial surgeries, and in electromyography analyses.
Vaginismus and dyspareunia: automatic vs. deliberate disgust responsivity.
Borg, Charmaine; de Jong, Peter J; Schultz, Willibrord Weijmar
2010-06-01
The difficulty of penetration experienced in vaginismus and dyspareunia may at least partly be due to a disgust-induced defensive response. To examine if sex stimuli specifically elicit: (i) automatic disgust-related memory associations; (ii) physiological disgust responsivity; and/or (iii) deliberate expression of disgust/threat. Two single target Implicit Association Task (st-IAT) and electromyography (EMG) were conducted on three groups: vaginismus (N = 24), dyspareunia (N = 24), and control (N = 31) group. st-IAT, to index their initial disgust-related associations and facial EMG for the m. levator labii and m. corrugator supercilii regions. Both clinical groups showed enhanced automatic sex-disgust associations. As a unique physiological expression of disgust, the levator activity was specifically enhanced for the vaginismus group, when exposed to a women-friendly SEX video clip. Also at the deliberate level, specifically the vaginismus group showed enhanced subjective disgust toward SEX pictures and the SEX clip, along with higher threat responses. Supporting the view that disgust is involved in vaginismus and dyspareunia, for both, clinical groups' sex stimuli automatically elicited associations with disgust. Particularly for the vaginismus group, these initial disgust associations persisted during subsequent validation processes and were also evident at the level of facial expression and self-report data. Findings are consistent with the notion that uncontrollable activated associations are involved in eliciting defensive reactions at the prospect of penetration seen in both conditions. Whereas deliberate attitudes, usually linked with the desire for having intercourse, possibly generate the distinction (e.g., severity) between these two conditions.
Paravaginal defect: anatomy, clinical findings, and imaging
Arenholt, Louise T.S.; Pedersen, Bodil Ginnerup; Glavind, Karin; Glavind-Kristensen, Marianne; DeLancey, John O.L.
2017-01-01
Introduction and Hypothesis The paravaginal defect has been a topic of active discussion concerning 1) what it is; 2) how to diagnose it; 3) its role in anterior vaginal wall prolapse; and 4) if and how to repair it. The aim of this article is to review the existing literature on the paravaginal defect and to discuss its role in the anterior vaginal wall support system, with an emphasis on anatomy and imaging. Methods Articles related to paravaginal defects were identified through a PUBMED search ending July 1, 2015. Results The support of the anterior vaginal wall is a complex system involving the levator ani muscle, the arcus tendineus fascia pelvis (ATFP), the pubocervical fascia, and the uterosacral/cardinal ligaments. Studies conclude that physical examination is inconsistent in detecting paravaginal defects. Ultrasound (US) and magnetic resonance imaging (MRI) have been used to describe patterns in the appearance of the vagina and bladder when a paravaginal defect is suspected. Different terms have been used (e.g. “sagging of bladder base,” “loss of tenting”), which all represent changes in the support of the pelvic floor but which could be due to both paravaginal defects and levator ani defects. Conclusion Paravaginal support plays a role in the support of the anterior vaginal wall, but we still do not know the degree to which it contributes to the development of prolapse. Both MRI and US are useful in the diagnosis of paravaginal defects, but further studies are needed to evaluate their use. PMID:27640064
Algorithms for the Reduction of Wind-Tunnel Data Derived from Strain Gauge Force Balances.
1984-05-01
summed. Where hinge moments are measured on a model, it is customary to express them by coefficients of the form C11 h (4.23) q Si dH where hi is the...measured hinge moment and Sit and dH are a characteristic area and length associated with the control surface. 4.6 Transformation to Body Axes...Pty. Ltd. Mr D. Pilkington Mr R. D. Bullen Commonwealth Aircraft Corporation, Libra Hawker de Havilland Aust. Pty. Ltd., Bankstown. L.ibrar
NASA Technical Reports Server (NTRS)
Goin, Kennith L
1951-01-01
Existing conical-flow solutions have been used to calculate the hinge-moments and effectiveness parameters of trailing-edge controls having leading and trailing edges swept ahead of the Mach lines and having streamwise root and tip chords. Equations and detailed charts are presented for the rapid estimation of these parameters. Also included is an approximate method by which these parameters may be corrected for airfoil-section thickness.
Structural Analysis of a Magnetically Actuated Silicon Nitride Micro-Shutter for Space Applications
NASA Technical Reports Server (NTRS)
Loughlin, James P.; Fettig, Rainer K.; Moseley, S. Harvey; Kutyrev, Alexander S.; Mott, D. Brent; Obenschain, Arthur F. (Technical Monitor)
2002-01-01
Finite element models have been created to simulate the electrostatic and electromagnetic actuation of a 0.5 micrometers silicon nitride micro-shutter for use in a spacebased Multi-object Spectrometer (MOS). The microshutter uses a torsion hinge to go from the closed, 0 degree, position, to the open, 90 degree position. Stresses in the torsion hinge are determined with a large deformation nonlinear finite element model. The simulation results are compared to experimental measurements of fabricated micro-shutter devices.
NASA Technical Reports Server (NTRS)
Likins, P. W.
1974-01-01
Equations of motion are derived for use in simulating a spacecraft or other complex electromechanical system amenable to idealization as a set of hinge-connected rigid bodies of tree topology, with rigid axisymmetric rotors and nonrigid appendages attached to each rigid body in the set. In conjunction with a previously published report on finite-element appendage vibration equations, this report provides a complete minimum-dimension formulation suitable for generic programming for digital computer numerical integration.
MR-defecography in obstructed defecation syndrome (ODS): technique, diagnostic criteria and grading.
Piloni, V; Tosi, P; Vernelli, M
2013-10-01
The aim of this study was to evaluate the use of a magnetic resonance (MR)-based classification system of obstructive defecation syndrome (ODS) to guide physicians in patient management. The medical records and imaging series of 105 consecutive patients (90 female, 15 male, aged 21-78 years, mean age 46.1 ± 5.1 years) referred to our center between April 2011 and January 2012 for symptoms of ODS were retrospectively examined. After history taking and a complete clinical examination, patients underwent MR imaging according to a standard protocol using a 0.35 T permanent field, horizontally oriented open-configuration magnet. Static and dynamic MR-defecography was performed using recognized parameters and well-established diagnostic criteria. Sixty-seven out of 105 (64 %) patients found the prone position more comfortable for the evacuation of rectal contrast while 10/105 (9.5 %) were unable to empty their rectum despite repeated attempts. Increased hiatus size, anterior rectocele and focal or extensive defects of the levator ani muscle were the most frequent abnormalities (67.6, 60.0 and 51.4 %, respectively). An MR-based classification was developed based on the combinations of abnormalities found: Grade 1 = functional abnormality, including paradoxical contraction of the puborectalis muscle, without anatomical defect affecting the musculo-fascial structures; Grade 2 = functional defect associated with a minor anatomical defect such as rectocele ≤ 2 cm in size and/or first-degree intussusception; Grade 3 = severe defects confined to the posterior anatomical compartment, including >2 cm rectocele, second- or higher-degree intussusception, full-thickness external rectal prolapse, poor mesorectal posterior fixation, rectal descent >5 cm, levator ani muscle rupture, ballooning of the levator hiatus and focal detachment of the endopelvic fascia; Grade 4 = combined defects of two or three pelvic floor compartments, including cystocele, hysterocele, enlarged urogenital hiatus, fascial tears enterocele or peritoneocele; Grade 5 = changes after failed surgical repair abscess/sinus tracts, rectal pockets, anastomotic strictures, small uncompliant rectum, kinking and/or lateral shift of supra-anastomotic portion and pudendal nerve entrapment. According to our classification, Grades 1 and 2 may be amenable to conservative therapy; Grade 3 may require surgical intervention by a coloproctologist; Grade 4 would need a combined urogynecological and coloproctological approach; and Grade 5 may require an even more complex multidisciplinary approach. Validation studies are needed to assess whether this MR-based classification system leads to a better management of patients with ODS.
Camp, Ariel L; Brainerd, Elizabeth L
2015-07-01
Suction-feeding fishes encompass a vast diversity of morphologies and ecologies, but during feeding they all rely on musculoskeletal linkages and levers to transform the shortening of muscle into 3D expansion of the mouth cavity. To relate the shape of these skeletal elements to their function in expansion of the mouth, four-bar linkage models have been developed and widely used in studies of ecology, evolution, and development. However, we have lacked the ability to test the predictions of these 2D linkage models against the actual 3D motions of fishes' skulls. A new imaging method, X-ray Reconstruction of Moving Morphology (XROMM), now makes it possible to measure 3D skeletal motions relative to other bones within the head and relative to the fish's body, and thereby to examine directly the proposed linkages. We used XROMM to examine the opercular linkage, in which shortening of the levator operculi muscle is hypothesized to retract the operculum, and thereby the interoperculum and interoperculomandibular ligament to generate depression of the lower jaw about the quadratomandibular joint. XROMM animations of suction strikes in largemouth bass revealed that the operculum is indeed retracted relative to the suspensorium as the levator operculi muscle shortens and the jaw depresses. However, the four-bar model of this linkage overestimates the depression of the jaw by nearly a factor of two. Therefore, caution should be used in interpreting and applying the predictions of this linkage model. When we measured kinematics relative to the fish's body, we found that the operculum was relatively stable, whereas the suspensorium was elevated along with the neurocranium, pushing the quadratomandibular joint forward to produce depression of the jaw. Thus, it is the epaxial muscles elevating the neurocranium that powers depression of the jaw through the opercular linkage. However, the levator operculi muscle plays a crucial role in stabilizing the operculum to allow elevation of the head to produce depression of the lower jaw. These results support the role of cranial muscles in controlling and transmitting power from the axial muscles, rather than generating substantial power themselves. We also demonstrate the utility of XROMM for assessing the function of this, and other, cranial linkages in suction-feeding fishes. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Qiu, Zhi-cheng; Wang, Xian-feng; Zhang, Xian-Min; Liu, Jin-guo
2018-07-01
A novel non-contact vibration measurement method using binocular vision sensors is proposed for piezoelectric flexible hinged plate. Decoupling methods of the bending and torsional low frequency vibration on measurement and driving control are investigated, using binocular vision sensors and piezoelectric actuators. A radial basis function neural network controller (RBFNNC) is designed to suppress both the larger and the smaller amplitude vibrations. To verify the non-contact measurement method and the designed controller, an experimental setup of the flexible hinged plate with binocular vision is constructed. Experiments on vibration measurement and control are conducted by using binocular vision sensors and the designed RBFNNC controllers, compared with the classical proportional and derivative (PD) control algorithm. The experimental measurement results demonstrate that the binocular vision sensors can detect the low-frequency bending and torsional vibration effectively. Furthermore, the designed RBF can suppress the bending vibration more quickly than the designed PD controller owing to the adjustment of the RBF control, especially for the small amplitude residual vibrations.
Modeling and design of a two-axis elliptical notch flexure hinge
NASA Astrophysics Data System (ADS)
Wu, Jianwei; Zhang, Yin; Lu, Yunfeng; Wen, Zhongpu; Bin, Deer; Tan, Jiubin
2018-04-01
As an important part of the joule balance system, the two-axis elliptical notch flexure hinge (TENFH) which typically consists of two single-axis elliptical notch flexure hinges was studied. First, a 6 degrees of freedom (6-DOF) compliance model was established based on the coordinate transformation method. In addition, the maximum stress of the TENFH was derived. The compliance and maximum stress model was verified using finite element analysis simulation. To decouple the attitude of the suspended coil system and reduce the offset between the centroid of the suspended coil mechanism and the mass comparator in the joule balance system, a new mechanical structure of TENFH was designed based on the compliance model and stress model proposed in this paper. The maximum rotation range is up to 10°, and the axial load is more than 5 kg, which meets the requirements of the system. The compliance model was also verified by deformation experimentation with the designed TENFH.
Determination of Elevator and Rudder Hinge Forces on the Learjet Model 55 Aircraft
NASA Technical Reports Server (NTRS)
Boroughs, R. R.; Padmanabhan, V.
1983-01-01
The empennage structure on the Learjet 55 aircraft was quite similar to the empennage structure on earlier Learjet models. However, due to an important structural change in the vertical fin along with the new loads environment on the 50 series aircraft, a structural test was required on the vertical fin, but the horizontal tail was substantiated by a comparative analysis with previous tests. NASTRAN analysis was used to investigate empennage deflections, stress levels, and control surface hinge forces. The hinge force calculations were made with the control surfaces in the deflected as well as undeflected configurations. A skin panel buckling analysis was also performed, and the non-linear effects of buckling were simulated in the NASTRAN model to more accurately define internal loads and stress levels. Comparisons were then made between the Model 55 and the Model 35/36 stresses and internal forces to determine which components were qualified by previous tests. Some of the methods and techniques used in this analysis are described.
NASA Astrophysics Data System (ADS)
McMahon, Paul; Jung, Hans-Juergen; Edwards, Jeff
2013-09-01
The Swarm programme consists of 3 magnetically clean satellites flying in close formation designed to measure the Earth's magnetic field using 2 Magnetometers mounted on a 4.3m long deployable boom.Deployment is initiated by releasing 3 HDRMs, once released the boom oscillates back and forth on a pair of pivots, similar to a restaurant kitchen door hinge, for around 120 seconds before coming to rest on 3 kinematic mounts which are used to provide an accurate reference location in the deployed position. Motion of the boom is damped through a combination of friction, spring hysteresis and flexing of the 120+ cables crossing the hinge. Considerable development work and accurate numerical modelling of the hinge motion was required to predict performance across a wide temperature range and ensure that during the 1st overshoot the boom did not damage itself, the harness or the spacecraft.Due to the magnetic cleanliness requirements of the spacecraft no magnetic materials could be used in the design of the hardware.
Bioengineered nisin derivatives with enhanced activity in complex matrices
Rouse, Susan; Field, Des; Daly, Karen M.; O'Connor, Paula M.; Cotter, Paul D.; Hill, Colin; Ross, R. Paul
2012-01-01
Summary Nisin A is the best known and most extensively characterized lantibiotic. As it is ribosomally synthesized, bioengineering‐based strategies can be used to generate variants. We have previously demonstrated that bioengineering of the hinge region of nisin A can result in the generation of variants with enhanced anti‐microbial activity against Gram‐positive pathogens. Here we created a larger bank of hinge variant producers and screened for producers that exhibit enhanced bioactivity as assessed by agar‐based assays against a selection of target strains. Further analysis of 12 ‘lead’ variants reveals that in many cases enhanced bioactivity is not attributable to enhanced specific activity but is instead as a consequence of an enhanced ability to diffuse through complex polymers. In the case of two variants, which contain the residues SVA and NAK, respectively, within the hinge region, we demonstrate that this enhanced trait enables the peptides to dramatically outperform nisin A with respect to controlling Listeria monocytogenes in commercially produced chocolate milk that contains carrageenan as a stabilizer. PMID:22260415
NASA Astrophysics Data System (ADS)
Tapken, Daniel; Steffensen, Thomas Bielefeldt; Leth, Rasmus; Kristensen, Lise Baadsgaard; Gerbola, Alexander; Gajhede, Michael; Jørgensen, Flemming Steen; Olsen, Lars; Kastrup, Jette Sandholm
2017-04-01
Ionotropic glutamate receptors (iGluRs) are responsible for most of the fast excitatory communication between neurons in our brain. The GluD2 receptor is a puzzling member of the iGluR family: It is involved in synaptic plasticity, plays a role in human diseases, e.g. ataxia, binds glycine and D-serine with low affinity, yet no ligand has been discovered so far that can activate its ion channel. In this study, we show that the hinge region connecting the two subdomains of the GluD2 ligand-binding domain is responsible for the low affinity of D-serine, by analysing GluD2 mutants with electrophysiology, isothermal titration calorimetry and molecular dynamics calculations. The hinge region is highly variable among iGluRs and fine-tunes gating activity, suggesting that in GluD2 this region has evolved to only respond to micromolar concentrations of D-serine.
Role for the MED21-MED7 Hinge in Assembly of the Mediator-RNA Polymerase II Holoenzyme.
Sato, Shigeo; Tomomori-Sato, Chieri; Tsai, Kuang-Lei; Yu, Xiaodi; Sardiu, Mihaela; Saraf, Anita; Washburn, Michael P; Florens, Laurence; Asturias, Francisco J; Conaway, Ronald C; Conaway, Joan W
2016-12-23
Mediator plays an integral role in activation of RNA polymerase II (Pol II) transcription. A key step in activation is binding of Mediator to Pol II to form the Mediator-Pol II holoenzyme. Here, we exploit a combination of biochemistry and macromolecular EM to investigate holoenzyme assembly. We identify a subset of human Mediator head module subunits that bind Pol II independent of other subunits and thus probably contribute to a major Pol II binding site. In addition, we show that binding of human Mediator to Pol II depends on the integrity of a conserved "hinge" in the middle module MED21-MED7 heterodimer. Point mutations in the hinge region leave core Mediator intact but lead to increased disorder of the middle module and markedly reduced affinity for Pol II. These findings highlight the importance of Mediator conformation for holoenzyme assembly. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Geothermal energy prospectivity of the Torrens Hinge Zone: evidence from new heat flow data
NASA Astrophysics Data System (ADS)
Matthews, Chris
2009-09-01
The Torrens Hinge Zone is a long but narrow (up to 40km wide) geological transition zone between the relatively stable Eastern Gawler Craton `Olympic Domain' to the west, and the sedimentary basin known as the Adelaide Geosyncline to the east. The author hypothesised from first principles that the Torrens Hinge Zone should be prospective for high geothermal gradients due to the likely presence of high heat flow and insulating cover rocks. A method to test this hypothesis was devised, which involved the determination of surface heat flow on a pattern grid using purpose-drilled wells, precision temperature logging and detailed thermal conductivity measurements. The results of this structured test have validated the hypothesis, with heat flow values over 90mW/m2 recorded in five of six wells drilled. With several kilometres thickness of moderate conductivity sediments overlying the crystalline basement in this region, predicted temperature at 5000m ranges between 200 and 300°C.
Tapken, Daniel; Steffensen, Thomas Bielefeldt; Leth, Rasmus; Kristensen, Lise Baadsgaard; Gerbola, Alexander; Gajhede, Michael; Jørgensen, Flemming Steen; Olsen, Lars; Kastrup, Jette Sandholm
2017-04-07
Ionotropic glutamate receptors (iGluRs) are responsible for most of the fast excitatory communication between neurons in our brain. The GluD2 receptor is a puzzling member of the iGluR family: It is involved in synaptic plasticity, plays a role in human diseases, e.g. ataxia, binds glycine and D-serine with low affinity, yet no ligand has been discovered so far that can activate its ion channel. In this study, we show that the hinge region connecting the two subdomains of the GluD2 ligand-binding domain is responsible for the low affinity of D-serine, by analysing GluD2 mutants with electrophysiology, isothermal titration calorimetry and molecular dynamics calculations. The hinge region is highly variable among iGluRs and fine-tunes gating activity, suggesting that in GluD2 this region has evolved to only respond to micromolar concentrations of D-serine.
Tapken, Daniel; Steffensen, Thomas Bielefeldt; Leth, Rasmus; Kristensen, Lise Baadsgaard; Gerbola, Alexander; Gajhede, Michael; Jørgensen, Flemming Steen; Olsen, Lars; Kastrup, Jette Sandholm
2017-01-01
Ionotropic glutamate receptors (iGluRs) are responsible for most of the fast excitatory communication between neurons in our brain. The GluD2 receptor is a puzzling member of the iGluR family: It is involved in synaptic plasticity, plays a role in human diseases, e.g. ataxia, binds glycine and D-serine with low affinity, yet no ligand has been discovered so far that can activate its ion channel. In this study, we show that the hinge region connecting the two subdomains of the GluD2 ligand-binding domain is responsible for the low affinity of D-serine, by analysing GluD2 mutants with electrophysiology, isothermal titration calorimetry and molecular dynamics calculations. The hinge region is highly variable among iGluRs and fine-tunes gating activity, suggesting that in GluD2 this region has evolved to only respond to micromolar concentrations of D-serine. PMID:28387240
Sim, Jaehyun; Sim, Jun; Park, Eunsung; Lee, Julian
2015-06-01
Many proteins undergo large-scale motions where relatively rigid domains move against each other. The identification of rigid domains, as well as the hinge residues important for their relative movements, is important for various applications including flexible docking simulations. In this work, we develop a method for protein rigid domain identification based on an exhaustive enumeration of maximal rigid domains, the rigid domains not fully contained within other domains. The computation is performed by mapping the problem to that of finding maximal cliques in a graph. A minimal set of rigid domains are then selected, which cover most of the protein with minimal overlap. In contrast to the results of existing methods that partition a protein into non-overlapping domains using approximate algorithms, the rigid domains obtained from exact enumeration naturally contain overlapping regions, which correspond to the hinges of the inter-domain bending motion. The performance of the algorithm is demonstrated on several proteins. © 2015 Wiley Periodicals, Inc.
A flight-dynamic helicopter mathematical model with a single flap-lag-torsion main rotor
NASA Technical Reports Server (NTRS)
Takahashi, Marc D.
1990-01-01
A mathematical model of a helicopter system with a single main rotor that includes rigid, hinge-restrained rotor blades with flap, lag, and torsion degrees of freedom is described. The model allows several hinge sequences and two offsets in the hinges. Quasi-steady Greenberg theory is used to calculate the blade-section aerodynamic forces, and inflow effects are accounted for by using three-state nonlinear dynamic inflow model. The motion of the rigid fuselage is defined by six degrees of freedom, and an optional rotor rpm degree of freedom is available. Empennage surfaces and the tail rotor are modeled, and the effect of main-rotor downwash on these elements is included. Model trim linearization, and time-integration operations are described and can be applied to a subset of the model in the rotating or nonrotating coordinate frame. A preliminary validation of the model is made by comparing its results with those of other analytical and experimental studies. This publication presents the results of research compiled in November 1989.
NASA Technical Reports Server (NTRS)
Taylor, John G.
1990-01-01
An investigation was conducted in the Static Test Facility of the NASA Langley 16-Foot Transonic Tunnel to determine the internal performance of two-dimensional convergent-divergent nozzles designed to have simultaneous pitch and yaw thrust vectoring capability. This concept utilized divergent flap rotation of thrust vectoring in the pitch plane and deflection of flat yaw flaps hinged at the end of the sidewalls for yaw thrust vectoring. The hinge location of the yaw flaps was varied at four positions from the nozzle exit plane to the throat plane. The yaw flaps were designed to contain the flow laterally independent of power setting. In order to eliminate any physical interference between the yaw flap deflected into the exhaust stream and the divergent flaps, the downstream corners of both upper and lower divergent flaps were cut off to allow for up to 30 deg of yaw flap deflection. The impact of varying the nozzle pitch vector angle, throat area, yaw flap hinge location, yaw flap length, and yaw flap deflection angle on nozzle internal performance characteristics, was studied. High-pressure air was used to simulate jet exhaust at nozzle pressure ratios up to 7.0. Static results indicate that configurations with the yaw flap hinge located upstream of the exit plane provide relatively high levels of thrust vectoring efficiency without causing large losses in resultant thrust ratio. Therefore, these configurations represent a viable concept for providing simultaneous pitch and yaw thrust vectoring.
Computational prediction of hinge axes in proteins
2014-01-01
Background A protein's function is determined by the wide range of motions exhibited by its 3D structure. However, current experimental techniques are not able to reliably provide the level of detail required for elucidating the exact mechanisms of protein motion essential for effective drug screening and design. Computational tools are instrumental in the study of the underlying structure-function relationship. We focus on a special type of proteins called "hinge proteins" which exhibit a motion that can be interpreted as a rotation of one domain relative to another. Results This work proposes a computational approach that uses the geometric structure of a single conformation to predict the feasible motions of the protein and is founded in recent work from rigidity theory, an area of mathematics that studies flexibility properties of general structures. Given a single conformational state, our analysis predicts a relative axis of motion between two specified domains. We analyze a dataset of 19 structures known to exhibit this hinge-like behavior. For 15, the predicted axis is consistent with a motion to a second, known conformation. We present a detailed case study for three proteins whose dynamics have been well-studied in the literature: calmodulin, the LAO binding protein and the Bence-Jones protein. Conclusions Our results show that incorporating rigidity-theoretic analyses can lead to effective computational methods for understanding hinge motions in macromolecules. This initial investigation is the first step towards a new tool for probing the structure-dynamics relationship in proteins. PMID:25080829
Hinge-deleted IgG4 blocker therapy for acetylcholine receptor myasthenia gravis in rhesus monkeys.
Losen, Mario; Labrijn, Aran F; van Kranen-Mastenbroek, Vivianne H; Janmaat, Maarten L; Haanstra, Krista G; Beurskens, Frank J; Vink, Tom; Jonker, Margreet; 't Hart, Bert A; Mané-Damas, Marina; Molenaar, Peter C; Martinez-Martinez, Pilar; van der Esch, Eline; Schuurman, Janine; de Baets, Marc H; Parren, Paul W H I
2017-04-20
Autoantibodies against ion channels are the cause of numerous neurologic autoimmune disorders. Frequently, such pathogenic autoantibodies have a restricted epitope-specificity. In such cases, competing antibody formats devoid of pathogenic effector functions (blocker antibodies) have the potential to treat disease by displacing autoantibodies from their target. Here, we have used a model of the neuromuscular autoimmune disease myasthenia gravis in rhesus monkeys (Macaca mulatta) to test the therapeutic potential of a new blocker antibody: MG was induced by passive transfer of pathogenic acetylcholine receptor-specific monoclonal antibody IgG1-637. The effect of the blocker antibody (IgG4Δhinge-637, the hinge-deleted IgG4 version of IgG1-637) was assessed using decrement measurements and single-fiber electromyography. Three daily doses of 1.7 mg/kg IgG1-637 (cumulative dose 5 mg/kg) induced impairment of neuromuscular transmission, as demonstrated by significantly increased jitter, synaptic transmission failures (blockings) and a decrease in the amplitude of the compound muscle action potentials during repeated stimulations (decrement), without showing overt symptoms of muscle weakness. Treatment with three daily doses of 10 mg/kg IgG4Δhinge-637 significantly reduced the IgG1-637-induced increase in jitter, blockings and decrement. Together, these results represent proof-of principle data for therapy of acetylcholine receptor-myasthenia gravis with a monovalent antibody format that blocks binding of pathogenic autoantibodies.
Lee, Winson C C; Kobayashi, Toshiki; Choy, Barton T S; Leung, Aaron K L
2012-06-01
A custom moulded ankle orthosis with hinged joints potentially offers a better control over the subtalar joint and the ankle joint during lateral cutting movements, due to total contact design and increase in material strength. To test the above hypothesis by comparing it to three other available orthoses. Repeated measures. Eight subjects with a history of ankle sprains (Grade 2), and 11 subjects without such history performed lateral cutting movements in four test conditions: 1) non-orthotic, 2) custom-moulded ankle orthosis with hinges, 3) Sport-Stirrup, and 4) elastic ankle sleeve with plastic support. A VICON motion analysis system was used to study the motions at the ankle and subtalar joints. The custom-moulded ankle orthosis significantly lowered the inversion angle at initial contact (p = 0.006) and the peak inversion angle (p = 0.000) during lateral cutting movements in comparison to non-orthotic condition, while the other two orthoses did not. The three orthoses did not affect the plantarflexion motions, which had been suggested by previous studies to be important in shock wave attenuation. The custom-moulded ankle orthosis with hinges could better control inversion and thus expected to better prevent ankle sprain in lateral cutting movements. Custom-moulded ankle orthoses are not commonly used in preventing ankle sprains. This study raises the awareness of the use of custom-moulded ankle orthoses which are expected to better prevent ankle sprains.
Shape Memory Alloy-Based Soft Gripper with Variable Stiffness for Compliant and Effective Grasping.
Wang, Wei; Ahn, Sung-Hoon
2017-12-01
Soft pneumatic actuators and motor-based mechanisms being concomitant with the cumbersome appendages have many challenges to making the independent robotic system with compact and lightweight configuration. Meanwhile, shape memory actuators have shown a promising alternative solution in many engineering applications ranging from artificial muscle to aerospace industry. However, one of the main limitations of such systems is their inherent softness resulting in a small actuation force, which prevents them from more effective applications. This issue can be solved by combining shape memory actuators and the mechanism of stiffness modulation. As a first, this study describes a shape memory alloy-based soft gripper composed of three identical fingers with variable stiffness for adaptive grasping in low stiffness state and effective holding in high stiffness state. Each finger with two hinges is fabricated through integrating soft composite actuator with stiffness changeable material where each hinge can approximately achieve a 55-fold changeable stiffness independently. Besides, each finger with two hinges can actively achieve multiple postures by both selectively changing the stiffness of hinges and actuating the relevant SMA wire. Based on these principles, the gripper is applicable for grasping objects with deformable shapes and varying shapes with a large range of weight where its maximum grasping force is increased to ∼10 times through integrating with the stiffness changeable mechanism. The final demonstration shows that the finger with desired shape-retained configurations enables the gripper to successfully pick up a frustum-shaped object.
A combined piezoelectric composite actuator and its application to wing/blade tips
NASA Astrophysics Data System (ADS)
Ha, Kwangtae
A novel combined piezoelectric-composite actuator configuration is proposed and analytically modeled in this work. The actuator is a low complexity, active compliant mechanism obtained by coupling a modified star cross sectional configuration composite beam with a helicoidal bimorph piezoelectric actuator coiled around it. This novel actuator is a good candidate as a hinge tension-torsion bar actuator for a helicopter rotor blade flap or blade tip and mirror rotational positioning. In the wing tip case, the tip deflection angle is different only according to the aerodynamic moment depending on the hinge position of the actuator along the chord and applied voltage because there is no centrifugal force. For an active blade tip subject to incompressible flow and 2D quasi steady airloads, its twist angle is related not only to aerodynamic moment and applied voltage but also to coupling terms, such as the trapeze effect and the tennis racquet effect. Results show the benefit of hinge position aft of the aerodynamic center, such that the blade tip response is amplified by airloads. Contrary to this effect, results also show that the centrifugal effects and inertial effect cause an amplitude reduction in the response. Summation of these effects determines the overall blade tip response. The results for a certain hinge position of Xh=1.5% chord aft of the quarter chord point proves that the tip deflection target design range of beta ∈ [-2,+2] can be achieved for all pitch angle configurations chosen.
Unattractive infant faces elicit negative affect from adults.
Schein, Stevie S; Langlois, Judith H
2015-02-01
We examined the relationship between infant attractiveness and adult affect by investigating whether differing levels of infant facial attractiveness elicit facial muscle movement correlated with positive and negative affect from adults (N=87) using electromyography. Unattractive infant faces evoked significantly more corrugator supercilii and levator labii superioris movement (physiological correlates of negative affect) than attractive infant faces. These results suggest that unattractive infants may be at risk for negative affective responses from adults, though the relationship between those responses and caregiving behavior remains elusive. Copyright © 2015 Elsevier Inc. All rights reserved.
Colonic motility in proctalgia fugax.
Harvey, R F
1979-10-06
Intraluminal pressure recordings were obtained from the rectum and sigmoid colon in two patients experiencing attacks of proctalgia fugax. In each patient the pain appeared to result from contractions of the sigmoid colon, and not from spasm of the levator ani, rectal wall muscle, or anal sphincters, all of which have previously been suggested as the source of such pain. Proctalgia fugax therefore appears, at least in some patients, to be an unusual variant of the irritable bowel syndrome, in which pain is referred from the sigmoid colon to the rectum.
Treatment of proctalgia fugax with topical nitroglycerin: report of a case.
Lowenstein, B; Cataldo, P A
1998-05-01
We report a single case of proctalgia fugax that responded to 0.3 percent nitroglycerin ointment. Case report. A single case of proctalgia fugax responded to topical application of 0.3 percent nitro glycerin ointment with no significant side effects. Nitroglycerin ointment is a newly described treatment for several painful anal conditions. We describe a single case of levator spasm or proctalgia fugax responding to topical application of nitroglycerin. This is only a single case report, and conclusive evidence awaits completion of a controlled clinical trial.
1992-04-01
fruits and vegetables , plentiful stocks of potatoes, fresh water and so forth. So they were doing all right. Q. Touchy area, but were you assisted by...34 to differentiate vegetation , roads, soils and depict special effects (e.g., dust clouds, explosions, smoke). Each pixel is assigned one of 4096 colors... vegetation and (di) roads. Lbind Featurcs. In ")L -era], land has bken modeled by digital eýlevation posts ona regular 125-meter ITEM gr-d. *he
NASA Astrophysics Data System (ADS)
Zamanov, A. D.
2002-01-01
Based on the exact three-dimensional equations of continuum mechanics and the Akbarov-Guz' continuum theory, the problem on forced vibrations of a rectangular plate made of a composite material with a periodically curved structure is formulated. The plate is rigidly fixed along the Ox 1 axis. Using the semi-analytic method of finite elements, a numerical procedure is elaborated for investigating this problem. The numerical results on the effect of structural curvings on the stress distribution in the plate under forced vibrations are analyzed. It is shown that the disturbances of the stress σ22 in a hinge-supported plate are greater than in a rigidly fixed one. Also, it is found that the structural curvings considerably affect the stress distribution in plates both under static and dynamic loading.
Lifting-surface theory for calculating the loading induced on a wing by a flap
NASA Technical Reports Server (NTRS)
Johnson, W. A.
1972-01-01
A method is described for using lifting-surface theory to obtain the pressure distribution on a wing with a trailing-edge flap or control surface. The loading has a logarithmic singularity at the flap edges, which may be determined directly by the method of matched asymptotic expansions. Expressions are given for the singular flap loading for various flap hinge line and side edge geometries, both for steady and unsteady flap deflection. The regular part of the flap loading must be obtained by inverting the lifting-surface-theory integral equation relating the pressure and the downwash on the wing: procedures are described to accomplish this for a general wing and flap geometry. The method is applied to several example wings, and the results are compared with experimental data. Theory and test correlate well.
Improving Photometric Calibration of Meteor Video Camera Systems
NASA Technical Reports Server (NTRS)
Ehlert, Steven; Kingery, Aaron; Cooke, William
2016-01-01
Current optical observations of meteors are commonly limited by systematic uncertainties in photometric calibration at the level of approximately 0.5 mag or higher. Future improvements to meteor ablation models, luminous efficiency models, or emission spectra will hinge on new camera systems and techniques that significantly reduce calibration uncertainties and can reliably perform absolute photometric measurements of meteors. In this talk we discuss the algorithms and tests that NASA's Meteoroid Environment Office (MEO) has developed to better calibrate photometric measurements for the existing All-Sky and Wide-Field video camera networks as well as for a newly deployed four-camera system for measuring meteor colors in Johnson-Cousins BV RI filters. In particular we will emphasize how the MEO has been able to address two long-standing concerns with the traditional procedure, discussed in more detail below.
Concepts, characterization, and modeling of MEMS microswitches with gold contacts in MUMPs
NASA Astrophysics Data System (ADS)
Lafontan, Xavier; Dufaza, Christian; Robert, Michel; Pressecq, Francis; Perez, Guy
2001-04-01
This paper demonstrates that RF MEMS micro-switches can be realized with a low cost MEMS technology such as MUMPs. Two different switches are proposed, namely the hinged beam switch and the gold overflowing switch. Their concepts, design and characterization are described in details. On-resistance as low as 5 - 6 (Omega) for the gold overflowing switch and 2 - 3 (Omega) for the hinged beam switch have been measured. Finally, experimental measurements showed that force and electrical current had strong influences on the overall electrical contact.
NASA Astrophysics Data System (ADS)
Khomchenko, V. G.; Varepo, L. G.; Glukhov, V. I.; Krivokhatko, E. A.
2017-06-01
The geometric model for the synthesis of third-class lever mechanisms is proposed, which allows, by changing the length of the auxiliary link and the position of its fixed hinge, to rearrange the movement of the working organ onto the cyclograms with different predetermined dwell times. It is noted that with the help of the proposed model, at the expense of the corresponding geometric constructions, the best uniform Chebyshev approximation can be achieved at the interval of the standstill.
Thermoelectric generator with hinged assembly for fins
Purdy, David L.; Shapiro, Zalman M.; Hursen, Thomas F.; Maurer, Gerould W.
1976-11-02
A cylindrical casing has a central shielded capsule of radioisotope fuel. A plurality of thermonuclear modules are axially arranged with their hot junctions resiliently pressed toward the shield and with their cold junctions adjacent a transition member having fins radiating heat to the environment. For each module, the assembly of transition member and fins is hinged to the casing for swinging to permit access to and removal of such module. A ceramic plate having gold layers on opposite faces prevents diffusion bonding of the hot junction to the shield.
Aerodynamic characteristics of horizontal tail surfaces
NASA Technical Reports Server (NTRS)
Silverstein, Abe; Katzoff, S
1940-01-01
Collected data are presented on the aerodynamic characteristics of 17 horizontal tail surfaces including several with balanced elevators and two with end plates. Curves are given for coefficients of normal force, drag, and elevator hinge moment. A limited analysis of the results has been made. The normal-force coefficients are in better agreement with the lifting-surface theory of Prandtl and Blenk for airfoils of low aspect ratio than with the usual lifting-line theory. Only partial agreement exists between the elevator hinge-moment coefficients and those predicted by Glauert's thin-airfoil theory.
Simplified Flutter Prevention Criteria for Personal Type Aircraft
1955-01-01
Play of Ailerons The total free play at the aileron edge of each aileron, when the other aileron is cla:nped to the wing should not exceed 2.5 percent of...the aileron chcrd aft of the hinge line at the station where the free play is measured. Elevator Balance Each elevator should be dynamically balanced...8217•. • . e •% f% ’dr-,•~~ • . S•, ,,,8- 2. The total free play at the tab trailing edge should be less than 2.5% of the tab chord aft of the hinge
Process of making medical clip
NASA Technical Reports Server (NTRS)
Baucom, R. M. (Inventor)
1984-01-01
An X-ray transparent and biologically inert medical clip for treating aneurisms and the like is disclosed, as well as a process for its production. A graphite reinforced composite film is molded into a unitary structure having a pair of hourglass-like cavities which are hinged together with a pair of jaws for grasping the aneurism extending from the wall of one cavity. A silicone rubber pellet is disposed in the other cavity to exert a spring force through the hinge area to normally bias the jaws into contact with each other.
Arakawa, Takashi; Abe, Hiroshi; Rodríguez-Vízquez, Jose Francisco; Murakami, Gen; Sugihara, Kenichi
2013-01-01
Purpose It is still unclear whether the longitudinal anal muscles or conjoint longitudinal coats (CLCs) are attached to the vagina, although such an attachment, if present, would appear to make an important contribution to the integrated supportive system of the female pelvic floor. Materials and Methods Using immunohistochemistry for smooth muscle actin, we examined semiserial frontal sections of 1) eleven female late-stage fetuses at 28-37 weeks of gestation, 2) two female middle-stage fetus (2 specimens at 13 weeks), and, 3) six male fetuses at 12 and 37 weeks as a comparison of the morphology. Results In late-stage female fetuses, the CLCs consistently (11/11) extended into the subcutaneous tissue along the vaginal vestibule on the anterior side of the external anal sphincter. Lateral to the CLCs, the external anal sphincter also extended anteriorly toward the vaginal side walls. The anterior part of the CLCs originated from the perimysium of the levator ani muscle without any contribution of the rectal longitudinal muscle layer. However, in 2 female middle-stage fetuses, smooth muscles along the vestibulum extended superiorly toward the levetor ani sling. In male fetuses, the CLCs were separated from another subcutaneous smooth muscle along the scrotal raphe (posterior parts of the dartos layer) by fatty tissue. Conclusion In terms of topographical anatomy, the female anterior CLCs are likely to correspond to the lateral extension of the perineal body (a bulky subcutaneous smooth muscle mass present in adult women), supporting the vaginal vestibule by transmission of force from the levator ani. PMID:23549829
Ye, Lin; Yao, Yuanyuan; Guo, Hui; Peng, Yun
2018-05-17
Blepharoptosis is a drooping of the upper eyelid, usually due to dysfunction of the levator palpebrae superioris (LPS). Recently, skeletal muscle satellite cells (SSCs) have been reported to promote the repair of damaged skeletal muscle. This study aims to investigate the potential contribution of exogenous SSCs to the regeneration of mechanically damaged LPS. Thirty-two rats were randomly divided into four groups, including control group, SSCs-treated group, SSCs-treated injury group and non-treated injury group. After rats in injury groups were artificially lacerated on both the left and right LPS, HBBS (Hank's Balanced Salt Solution) containing SSCs was injected into upper eyelid tissue. After 7 days, the LPS muscle tissues were excised. In addition, skeletal muscle cells (SMCs) and SSCs were cocultured for use as an in vitro model, and the protective effects of SSCs on cultured SMCs were also investigated. Histological staining revealed that exogenous SSCs repaired the damaged muscle fibers and attenuated the fibrosis of LPS, possibly due to the increased level of IGF-1. In contrast, the level of IL-1β, IL-6, TGF-β1 and Smad2/3 (phospho-T8) were significantly reduced in the SSCs-treated group. The in vitro model using coculture of skeletal muscle cells (SMCs) and SSCs also revealed an increased level of IGF-1 and reduced level of inflammatory factors, resulting in a better cell survival rate. This study found that exogenous SSCs can promote the repair of LPS mechanical damage and provides new insight into the development of novel therapeutic approaches for blepharoptosis.
Krofta, Ladislav; Havelková, Linda; Urbánková, Iva; Krčmář, Michal; Hynčík, Luděk; Feyereisl, Jaroslav
2017-02-01
During vaginal delivery, the levator ani muscle (LAM) undergoes severe deformation. This stress can lead to stretch-related LAM injuries. The objective of this study was to develop a sophisticated MRI-based model to simulate changes in the LAM during vaginal delivery. A 3D finite element model of the female pelvic floor and fetal head was developed. The model geometry was based on MRI data from a nulliparous woman and 1-day-old neonate. Material parameters were estimated using uniaxial test data from the literature and by least-square minimization method. The boundary conditions reflected all anatomical constraints and supports. A simulation of vaginal delivery with regard to the cardinal movements of labor was then performed. The mean stress values in the iliococcygeus portion of the LAM during fetal head extension were 4.91-7.93 MPa. The highest stress values were induced in the pubovisceral and puborectal LAM portions (mean 27.46 MPa) at the outset of fetal head extension. The last LAM subdivision engaged in the changes in stress was the posteromedial section of the puborectal muscle. The mean stress values were 16.89 MPa at the end of fetal head extension. The LAM was elongated by nearly 2.5 times from its initial resting position. The cardinal movements of labor significantly affect the subsequent heterogeneous stress distribution in the LAM. The absolute stress values were highest in portions of the muscle that arise from the pubic bone. These areas are at the highest risk for muscle injuries with long-term complications.
Yuzuriha, Shunsuke; Matsuo, Kiyoshi; Ban, Ryokuya; Yano, Shiharu; Moriizumi, Tetsuji
2012-01-01
Background: We previously reported that the supratarsal Mueller's muscle is innervated by both sympathetic efferent fibers and trigeminal proprioceptive afferent fibers, which function as mechanoreceptors-inducing reflexive contractions of both the levator and frontalis muscles. Controversy still persists regarding the role of the mechanoreceptors in Mueller's muscle; therefore, we clinically and histologically investigated Mueller's muscle. Methods: We evaluated the role of phenylephrine administration into the upper fornix in contraction of Mueller's smooth muscle fibers and how intraoperative stretching of Mueller's muscle alters the degree of eyelid retraction in 20 patients with aponeurotic blepharoptosis. In addition, we stained Mueller's muscle in 7 cadavers with antibodies against α-smooth muscle actin, S100, tyrosine hydroxylase, c-kit, and connexin 43. Results: Maximal eyelid retraction occurred approximately 3.8 minutes after administration of phenylephrine and prolonged eyelid retraction for at least 20 minutes after administration. Intraoperative stretching of Mueller's muscle increased eyelid retraction due to its reflexive contraction. The tyrosine hydroxylase antibody sparsely stained postganglionic sympathetic nerve fibers, whereas the S100 and c-kit antibodies densely stained the interstitial cells of Cajal (ICCs) among Mueller's smooth muscle fibers. A connexin 43 antibody failed to stain Mueller's muscle. Conclusions: A contractile network of ICCs may mediate neurotransmission within Mueller's multiunit smooth muscle fibers that are sparsely innervated by postganglionic sympathetic fibers. Interstitial cells of Cajal may also serve as mechanoreceptors that reflexively contract Mueller's smooth muscle fibers, forming intimate associations with intramuscular trigeminal proprioceptive fibers to induce reflexive contraction of the levator and frontalis muscles. PMID:22359687
Is levator hiatus distension associated with peripheral ligamentous laxity during pregnancy?
Gachon, Bertrand; Fritel, Xavier; Fradet, Laetitia; Decatoire, Arnaud; Lacouture, Patrick; Panjo, Henri; Pierre, Fabrice; Desseauve, David
2017-08-01
The impact of pregnancy on pelvic floor disorders remains poorly understood. During pregnancy, an increase in ligamentous laxity and pelvic organ mobility is often reported. Our main objective was to investigate a possible association between peripheral ligamentous laxity and levator hiatus (LH) distension during pregnancy. This was a prospective longitudinal study of 26 pregnant women followed up from the first to the third trimester. We collected the following information: occurrence of pelvic organ prolapse (POP) symptoms (score higher than 0 for the POP section of the Pelvic Floor Distress Inventory 20 questions score), 4D perineal ultrasound scan results with LH distension assessment and measurement of metacarpophalangeal joint mobility (MCP laxity). The association between MCP laxity and LH distension was estimated by mixed multilevel linear regression. The associations between MCP laxity and categorical parameters were estimated in a multivariate analysis using a generalized estimating equation model. MCP laxity and LH distension were correlated with a correlation coefficient of 0.26 (p = 0.02), and 6.8% of the LH distension variance was explained by MCP laxity. In the multivariate analysis, MCP laxity was associated with POP symptoms with an odds ratio at 1.05 (95% CI 1.01-1.11) for an increase of 1° in MCP laxity. LH distension and peripheral ligamentous laxity are significantly associated during pregnancy. However, the relationship is weak, and the results need to be confirmed in larger populations and with more specific techniques such as elastography to directly assess the elastic properties of the pelvic floor muscles.
Houston, Kevin E.; Tomasi, Matteo; Amaral, Christina; Finch, Nicole; Yoon, Michael K.; Lee, Hang; Paschalis, Eleftherios I.
2018-01-01
Purpose We further optimized and evaluated the safety of the magnetic levator prosthesis (MLP) for temporary management of severe blepharoptosis, and compared efficacy and comfort against the ptosis crutch. Methods The interpalpebral fissure (IPF) of participants (n = 12) with ptosis was measured during attempted eyelid opening, volitional closing, and spontaneous closing with no device, ptosis crutch, or the MLP. A 10-point scale documented comfort. Additionally, a 20 minute and then 1 week trial of the MLP was offered. Safety measures were skin erythema rating, change in visual acuity, and change in corneal staining. Results The MLP and crutch opened the eye (IPF 11.2 and 9.3 mm), but the MLP allowed better volitional closure (IPF 1.0 vs. 4.9 mm, P = 0.009), but was no better in allowing spontaneous blink (IPF 7.5 vs. 7.7 mm, P = 0.722). Both devices were equally comfortable (both median 8/10 comfort, P = 0.46). With extended use, opening with the MLP showed IPF 9.24 mm at 20 minutes and 9.46 mm at 1 week, and volitional closure was IPF 0.95 and 0.52 mm, respectively. Closure on spontaneous blink improved with extended wear to IPF 5.14 and 5.18 mm, respectively (P = 0.002). Two participants exhibited moderate skin erythema and one had increased corneal staining without change in acuity. Conclusions The MLP is safe and feasible for temporary correction of severe ptosis. Translational Relevance First group data in patients showing successful reanimation of the eyelid with magnetic force. PMID:29367892
Modeling and design of a high-performance hybrid actuator
NASA Astrophysics Data System (ADS)
Aloufi, Badr; Behdinan, Kamran; Zu, Jean
2016-12-01
This paper presents the model and design of a novel hybrid piezoelectric actuator which provides high active and passive performances for smart structural systems. The actuator is composed of a pair of curved pre-stressed piezoelectric actuators, so-called commercially THUNDER actuators, installed opposite each other using two clamping mechanisms constructed of in-plane fixable hinges, grippers and solid links. A fully mathematical model is developed to describe the active and passive dynamics of the actuator and investigate the effects of its geometrical parameters on the dynamic stiffness, free displacement and blocked force properties. Among the literature that deals with piezoelectric actuators in which THUNDER elements are used as a source of electromechanical power, the proposed study is unique in that it presents a mathematical model that has the ability to predict the actuator characteristics and achieve other phenomena, such as resonances, mode shapes, phase shifts, dips, etc. For model validation, the measurements of the free dynamic response per unit voltage and passive acceleration transmissibility of a particular actuator design are used to check the accuracy of the results predicted by the model. The results reveal that there is a good agreement between the model and experiment. Another experiment is performed to teste the linearity of the actuator system by examining the variation of the output dynamic responses with varying forces and voltages at different frequencies. From the results, it can be concluded that the actuator acts approximately as a linear system at frequencies up to 1000 Hz. A parametric study is achieved here by applying the developed model to analyze the influence of the geometrical parameters of the fixable hinges on the active and passive actuator properties. The model predictions in the frequency range of 0-1000 Hz show that the hinge thickness, radius, and opening angle parameters have great effects on the frequency dynamic responses, passive isolation characteristics and the locations of their peaks and dips. Furthermore, the output actuating force can be improved by increasing the hinge hardness, which is controlled by its dimensions, although increasing the hinge hardness may cause a decrease in the free displacement and passive insulation performance, particularly at low frequencies.
Biomechanical testing of a PEEK-based dynamic instrumentation device in a lumbar spine model.
Herren, Christian; Beckmann, Agnes; Meyer, Sabine; Pishnamaz, Miguel; Mundt, Marion; Sobottke, Rolf; Prescher, Andreas; Stoffel, Marcus; Markert, Bernd; Kobbe, Philipp; Pape, Hans-Christoph; Eysel, Peer; Siewe, Jan
2017-05-01
The purpose of this study was to investigate the range-of-motion after posterior polyetheretherketone-based rod stabilisation combined with a dynamic silicone hinge in order to compare it with titanium rigid stabilisation. Five human cadaveric lumbar spines with four vertebra each (L2 to L5) were tested in a temperature adjustable spine-testing set-up in four trials: (1) native measurement; (2) kinematics after rigid monosegmental titanium rod instrumentation with anterior intervertebral bracing of the segment L4/5; (3) kinematics after hybrid posterior polyetheretherketone rod instrumentation combined with a silicone hinge within the adjacent level (L3/4) and (4) kinematics after additional decompression with laminectomy of L4 and bilateral resection of the inferior articular processes (L3). During all steps, the specimens were loaded quasi-statically with 1°/s with pure moment up to 7.5Nm in flexion/extension, lateral bending and axial rotation. In comparison to the native cadaveric spine, both the titanium device and polyetheretherketone-based device reduce the range-of-motion within the level L4/5 significantly (flexion/extension: reduction of 77%, p<0.001; lateral bending: reduction of 62%, p<0.001; axial rotation: reduction of 71%, p<0.001). There was a clear stabilisation effect after hybrid-instrumentation within the level L3/4, especially in flexion/extension (64%, p<0.001) and lateral bending (62%, p<0.001) but without any effect on the axial rotation. Any temperature dependency has not been observed. Surprisingly, the hybrid device compensates for laminectomy L4 and destabilising procedure within the level L3/4 in comparison to other implants. Further studies must be performed to show its effectiveness regarding the adjacent segment instability. Copyright © 2017 Elsevier Ltd. All rights reserved.
Intracardiac ultrasound scanner using a micromachine (MEMS) actuator.
Zara, J M; Bobbio, S M; Goodwin-Johansson, S; Smith, S W
2000-01-01
Catheter-based intracardiac ultrasound offers the potential for improved guidance of interventional cardiac procedures. The objective of this research is the development of catheter-based mechanical sector scanners incorporating high frequency ultrasound transducers operating at frequencies up to 20 MHz. The authors' current transducer assembly consists of a single 1.75 mm by 1.75 mm, 20 MHz, PZT element mounted on a 2 mm by 2 mm square, 75 mum thick polyimide table that pivots on 3-mum thick gold plated polyimide hinges. The hinges also serve as the electrical connections to the transducer. This table-mounted transducer is tilted using a miniature linear actuator to produce a sector scan. This linear actuator is an integrated force array (IFA), which is an example of a micromachine, i.e., a microelectromechanical system (MEMS). The IFA is a thin (2.2 mum) polyimide membrane, which consists of a network of hundreds of thousands of micron scale deformable capacitors made from pairs of metallized polyimide plates. IFAs contract with an applied voltage of 30-120 V and have been shown to produce strains as large as 20% and forces of up to 8 dynes. The prototype transducer and actuator assembly was fabricated and interfaced with a GagePCI analog to digital conversion board digitizing 12 bit samples at a rate of 100 MSamples/second housed in a personal computer to create a single channel ultrasound scanner. The deflection of the table transducer in a low viscosity insulating fluid (HFE 7100, 3M) is up to +/-10 degrees at scan rates of 10-60 Hz. Software has been developed to produce real-time sector scans on the PC monitor.
NASA Astrophysics Data System (ADS)
Kolawole, F.; Atekwana, E. A.; Laó-Dávila, D. A.; Abdelsalam, M. G.; Chindandali, P. R.; Salima, J.; Kalindekafe, L.
2018-03-01
We integrated temporal aeromagnetic data and recent earthquake data to address the long-standing question on the role of preexisting Precambrian structures in modulating strain accommodation and subsequent ruptures leading to seismic events within the East African Rift System. We used aeromagnetic data to elucidate the relationship between the locations of the 2009 Mw 6.0 Karonga, Malawi, earthquake surface ruptures and buried basement faults along the hinge zone of the half-graben comprising the North Basin of the Malawi Rift. Through the application of derivative filters and depth-to-magnetic-source modeling, we identified and constrained the trend of the Precambrian metamorphic fabrics and correlated them to the three-dimensional structure of buried basement faults. Our results reveal an unprecedented detail of the basement fabric dominated by high-frequency WNW to NW trending magnetic lineaments associated with the Precambrian Mughese Shear Zone fabric. The high-frequency magnetic lineaments are superimposed by lower frequency NNW trending magnetic lineaments associated with possible Cenozoic faults. Surface ruptures associated with the 2009 Mw 6.0 Karonga earthquake swarm aligned with one of the NNW-trending magnetic lineaments defining a normal fault that is characterized by right-stepping segments along its northern half and coalesced segments on its southern half. Fault geometries, regional kinematics, and spatial distribution of seismicity suggest that seismogenic faults reactivated the basement fabric found along the half-graben hinge zone. We suggest that focusing of strain accommodation and seismicity along the half-graben hinge zone is facilitated and modulated by the presence of the basement fabric.
Sánchez, Isis M; Gaud-Quintana, Sadja; Stern, Jacob K
Lip repositioning surgery to address excessive gingival display induced by different etiologies has received major attention recently. Several techniques and variations have been reported, including myotomy or repositioning of the levator labii superioris muscle, Le Fort impaction, maxillary gingivectomies, botulinum toxin injections, and lip stabilization. This study reports a case of excessive gingival display treated by a modified combined approach. A 25-year-old woman with a 4- to 8-mm gingival display when smiling caused by a combination of short clinical crowns induced by an altered passive eruption and hypermobility of the upper lip underwent a staged esthetic crown-lengthening procedure followed by a modified lip repositioning technique. A description of the technique and a comparison with other modes of therapy is discussed. This modified approach for treating the hypermobile lip included a bilateral removal of a partial-thickness strip of mucosa from the maxillary buccal vestibule without severing the muscle, leaving the midline frenum intact and suturing the lip mucosa to the mucogingival line. The narrower vestibule and increased tooth length resulted in a symmetric and pleasing gingival display when smiling that remained stable over time. With proper diagnosis and sequence of therapy, modified lip repositioning surgery combined with esthetic crown lengthening can be used predictably to treat excessive gingival display and enhance smile esthetics.
Cysteine Racemization on IgG Heavy and Light Chains
Zhang, Qingchun; Flynn, Gregory C.
2013-01-01
Under basic pH conditions, the heavy chain 220-light chain 214 (H220-L214) disulfide bond, found in the flexible hinge region of an IgG1, can convert to a thioether. Similar conditions also result in racemization of the H220 cysteine. Here, we report that racemization occurs on both H220 and L214 on an IgG1 with a λ light chain (IgG1λ) but almost entirely on H220 of an IgGl with a κ light chain (IgG1κ) under similar conditions. Likewise, racemization was detected at significant levels on H220 and L214 on endogenous human IgG1λ but only at the H220 position on IgG1κ. Low but measurable levels of d-cysteines were found on IgG2 cysteines in the hinge region, both with monoclonal antibodies incubated under basic pH conditions and on antibodies isolated from human serum. A simplified reaction mechanism involving reversible β-elimination on the cysteine is presented that accounts for both base-catalyzed racemization and thioether formation at the hinge disulfide. PMID:24142697
NASA Technical Reports Server (NTRS)
Aoyagi, Kiyoshi; Hickey, David H.
1959-01-01
Previous investigations have shown that increased blowing at the hinge-line radius of a plain flap will give flap lift increases above that realized with boundary-layer control. Other experiments and theory have shown that blowing from a wing trailing edge, through the jet flap effect, produced lift increases. The present investigation was made to determine whether blowing simultaneously at the hinge-line radius and trailing edge would be more effective than blowing separately at either location. The tests were made at a Reynolds number of 4.5 x 10(exp 6) with a 35 deg sweptback-wing airplane. For this report, only the lift data are presented. Of the three flap blowing arrangements tested, blowing distributed between the trailing edge and the hinge-line radius of a plain flap was found to be superior to blowing at either location separately at the plain flap deflections of interest. Comparison of estimated and experimental jet flap effectiveness was fair.
How does a woodpecker work? An impact dynamics approach
NASA Astrophysics Data System (ADS)
Liu, Yuzhe; Qiu, Xinming; Yu, Tongxi; Tao, Jiawei; Cheng, Ze
2015-04-01
To understand how a woodpecker is able accelerate its head to such a high velocity in a short amount of time, a multi-rigid-segment model of a woodpecker's body is established in this study. Based on the skeletal specimen of the woodpecker and several videos of woodpeckers pecking, the parameters of a three-degree-of-freedom system are determined. The high velocity of the head is found to be the result of a whipping effect, which could be affected by muscle torque and tendon stiffness. The mechanism of whipping is analyzed by comparing the response of a hinged rod to that of a rigid rod. Depending on the parameters, the dynamic behavior of a hinged rod is classified into three response modes. Of these, a high free-end velocity could be achieved in mode II. The model is then generalized to a multihinge condition, and the free-end velocity is found to increase with hinge number, which explains the high free-end velocity resulting from whipping. Furthermore, the effects of some other factors, such as damping and mass distribution, on the velocity are also discussed.
NASA Technical Reports Server (NTRS)
Hughes, M. T.; Mennell, R. C.
1974-01-01
Experimental aerodynamic investigations were conducted on an 0.015-scale representation of the integrated space shuttle launch vehicle in the trisonic wind tunnel. The primary test objective was to obtain subsonic and transonic elevon and bodyflap hinge moments and wing bending-torsion moments in the presence of the launch vehicle. Wing pressures were also recorded for the upper and lower right wing surfaces at two spanwise stations. The hinge moment, wing bending/torsion moments and wing pressure data were recorded over an angle-of-attack (alpha) range from -8 deg to +8 deg, and angle-of-sideslip (beta) range from -8 deg to +8 deg and at Mach numbers of 0.90, 1.12, 1.24 and 1.50. Tests were also conducted to determine the effects of the orbiter rear attach cross beam and the forward attach wedge and strut diameter. The orbiter alone was tested at 0.90 and 1.24 Mach number only.
NASA Technical Reports Server (NTRS)
Herman, G. C.
1986-01-01
A lateral guidance algorithm which controls the location of the line of intersection between the actual and desired orbital planes (the hinge line) is developed for the aerobraking phase of a lift-modulated orbital transfer vehicle. The on-board targeting algorithm associated with this lateral guidance algorithm is simple and concise which is very desirable since computation time and space are limited on an on-board flight computer. A variational equation which describes the movement of the hinge line is derived. Simple relationships between the plane error, the desired hinge line position, the position out-of-plane error, and the velocity out-of-plane error are found. A computer simulation is developed to test the lateral guidance algorithm for a variety of operating conditions. The algorithm does reduce the total burn magnitude needed to achieve the desired orbit by allowing the plane correction and perigee-raising burn to be combined in a single maneuver. The algorithm performs well under vacuum perigee dispersions, pot-hole density disturbance, and thick atmospheres. The results for many different operating conditions are presented.
Qin, Guangzhao; Yan, Qing-Bo; Qin, Zhenzhen; Yue, Sheng-Ying; Cui, Hui-Juan; Zheng, Qing-Rong; Su, Gang
2014-01-01
We systematically investigated the geometric, electronic and thermoelectric (TE) properties of bulk black phosphorus (BP) under strain. The hinge-like structure of BP brings unusual mechanical responses such as anisotropic Young's modulus and negative Poisson's ratio. A sensitive electronic structure of BP makes it transform among metal, direct and indirect semiconductors under strain. The maximal figure of merit ZT of BP is found to be 0.72 at 800 K that could be enhanced to 0.87 by exerting an appropriate strain, revealing BP could be a potential medium-high temperature TE material. Such strain-induced enhancements of TE performance are often observed to occur at the boundary of the direct-indirect band gap transition, which can be attributed to the increase of degeneracy of energy valleys at the transition point. By comparing the structure of BP with SnSe, a family of potential TE materials with hinge-like structure are suggested. This study not only exposes various novel properties of BP under strain, but also proposes effective strategies to seek for better TE materials. PMID:25374306
NASA Astrophysics Data System (ADS)
Choi, JungHwan
In this project, an eye dosimeter was designed for monitoring occupational lens of the eye exposures targeted to interventional radiologists who are often indirectly exposed to scattered radiation from the patient while performing image-guided procedures. The dosimeter was designed with a computer-aided design software to facilitate additive manufacturing techniques to make the dosimeter. The dosimeter consisted of three separate components that are attached to the hinges and the bridge of the occupational worker's protective eyewear. The produced dosimeter was radiologically calibrated to measure the lens dose on an anthropomorphic phantom of the human head. To supplement the physical design, an algorithm was written that prompts the user to input the element responses of the dosimeter, then estimates the average angle, energy, and resulting lens dose of the exposure by comparing the input with the data acquired during the dosimeter calibration procedure. The performance of the calibrated dosimeter (and the algorithm) was evaluated according to guidelines of the American National Standards Institute, and the dosimeter demonstrated a performance that was in compliance with the standard's performance criteria which suggests that the design of the eye dosimeter is feasible.
Standard operating procedures for Peyronie's disease.
Levine, Laurence A; Burnett, Arthur L
2013-01-01
Peyronie's disease (PD) refers to a penile deformity that is associated with sexual dysfunction. To provide recommendations and Standard Operating Procedures (SOPs) based on best evidence for diagnosis and treatment of PD. Medical literature was reviewed and combined with expert opinion of the authors. Recommendations and SOPs based on grading of evidence-based medical literature. PD is a fibrotic wound-healing disorder involving the tunica albuginea of the corpora cavernosa. The resulting scar is responsible for a variety of deformities, including curvature, shortening, narrowing with hinge effect, and is frequently associated in the early phase with pain. Patients frequently experience diminished quality erections. All of these conditions can compromise sexual function for the affected male. The etiopathophysiology of PD has yet to be clarified and as a result, effective, reliable, mechanistic directed non-surgical therapy is lacking. The management of PD consists of proper diagnosis and treatment, ranging from non-surgical to surgical interventions. The main state of treatment for PD rests at this time on surgical correction that should be based on clear indications, involve surgical consent, and follow a surgical algorithm that includes tunica plication, plaque incision/partial excision and grafting, and penile prosthesis implantation. © 2012 International Society for Sexual Medicine.
Application of Balancing Tabs to Ailerons
NASA Technical Reports Server (NTRS)
Sears, Richard I.
1942-01-01
Analysis was made to determine characteristics required of a balancing-tab system for ailerons in order to reduce aileron stick forces to any desired magnitude. Series of calculations based on section data were made to determine balancing-tab systems of various chord tabs and ailerons that will give, for a particular airplane, zero rate of aileron hinge moment with aileron deflection and yet will produce same maximum rate of roll as a plain unbalanced 15-percent chord aileron of same span. Effects of rolling velocity and of forces in tab link on aileron hinge moments have been included.
NASA Technical Reports Server (NTRS)
Macala, G. A.
1983-01-01
A computer program is described that can automatically generate symbolic equations of motion for systems of hinge-connected rigid bodies with tree topologies. The dynamical formulation underlying the program is outlined, and examples are given to show how a symbolic language is used to code the formulation. The program is applied to generate the equations of motion for a four-body model of the Galileo spacecraft. The resulting equations are shown to be a factor of three faster in execution time than conventional numerical subroutines.
NASA Technical Reports Server (NTRS)
Fleischer, G. E.
1973-01-01
A new computer subroutine, which solves the attitude equations of motion for any vehicle idealized as a topological tree of hinge-connected rigid bodies, is used to simulate and analyze science instrument pointing control interaction with a flexible Mariner Venus/Mercury (MVM) spacecraft. The subroutine's user options include linearized or partially linearized hinge-connected models whose computational advantages are demonstrated for the MVM problem. Results of the pointing control/flexible vehicle interaction simulations, including imaging experiment pointing accuracy predictions and implications for MVM science sequence planning, are described in detail.
Flow over a cylinder with a hinged-splitter plate
NASA Astrophysics Data System (ADS)
Shukla, S.; Govardhan, R. N.; Arakeri, J. H.
2009-05-01
Previous work on rigid splitter plates in the wake of a bluff body has shown that the primary vortex shedding can be suppressed for sufficiently long splitter plates. In the present work, we study the problem of a hinged-splitter plate in the wake of a circular cylinder. The splitter plate can rotate about the hinge at the base of the cylinder due to the unsteady fluid forces acting on it, and hence the communication between the two sides of the wake is not totally disrupted as in the rigid splitter plate case. In our study, we investigate this problem in the limit where the stiffness and internal damping associated with the hinge are negligible, and the mass ratio of the splitter plate is small. The experiments show that the splitter plate oscillations increase with Reynolds numbers at low values of Re, and are found to reach a saturation amplitude level at higher Re, Re>4000. This type of saturation amplitude level that appears to continue indefinitely with Re, appears to be related to the fact that there is no structural restoring force, and has been observed previously for transversely oscillating cylinders with no restoring force. In the present case, the saturation tip amplitude level can be up to 0.45D, where D is the cylinder diameter. For this hinged-rigid splitter plate case, it is found that the splitter plate length to cylinder diameter ratio (L/D) is crucial in determining the character and magnitude of the oscillations. For small splitter plate lengths (L/D⩽3.0), the oscillations appear to be nearly periodic with tip amplitudes of about 0.45D nearly independent of L/D. The nondimensional oscillation frequencies (fD/U) on the other hand are found to continuously vary with L/D from fD/U≈0.2 at L/D=1 to fD/U≈0.1 at L/D=3. As the splitter plate length is further increased beyond L/D⩾4.0, the character of the splitter plate oscillations suddenly changes. The oscillations become aperiodic with much smaller amplitudes. In this long splitter plate regime, the spectra of the oscillations become broadband, and are reminiscent of the change in character of the wake oscillations seen in the earlier fixed-rigid splitter plate case for L/D⩾5.0. In the present case of the hinged-splitter plate, the sudden transition seen as the splitter plate length (L/D) is increased from 3 to 4 may be attributed to the fact that the wake vortices are no longer able to synchronize with the plate motions for larger splitter plate lengths. Hence, as observed in other vortex-induced vibration problems, the oscillations become aperiodic and the amplitude reduces dramatically.
Experimental and Analytical Seismic Studies of a Four-Span Bridge System with Innovative Materials
NASA Astrophysics Data System (ADS)
Cruz Noguez, Carlos Alonso
As part of a multi-university project utilizing the NSF Network for Earthquake Engineering Simulation (NEES), a quarter-scale model of a four-span bridge incorporating plastic hinges with different advanced materials was tested to failure on the three shake table system at the University of Nevada, Reno (UNR). The bridge was the second test model in a series of three 4-span bridges, with the first model being a conventional reinforced-concrete (RC) structure. The purpose of incorporating advanced materials was to improve the seismic performance of the bridge with respect to two damage indicators: (1) column damage and (2) permanent deformations. The goals of the study presented in this document were to (1) evaluate the seismic performance of a 4-span bridge system incorporating SMA/ECC and built-in rubber pad plastic hinges as well as post-tensioned piers, (2) quantify the relative merit of these advanced materials and details compared to each other and to conventional reinforced concrete plastic hinges, (3) determine the influence of abutment-superstructure interaction on the response, (4) examine the ability of available elaborate analytical modeling techniques to model the performance of advanced materials and details, and (5) conduct an extensive parametric study of different variations of the bridge model to study several important issues in bridge earthquake engineering. The bridge model included six columns, each pair of which utilized a different advanced detail at bottom plastic hinges: shape memory alloys (SMA), special engineered cementitious composites (ECC), elastomeric pads embedded into columns, and post-tensioning tendons. The design of the columns, location of the bents, and selection of the loading protocol were based on pre-test analyses conducted using computer program OpenSees. The bridge model was subjected to two-horizontal components of simulated earthquake records of the 1994 Northridge earthquake. Over 340 channels of data were collected. The test results showed the effectiveness of the advanced materials in reducing damage and permanent displacements. The damage was minimal in plastic hinges with SMA/ECC and those with built-in elastomeric pads. Conventional RC plastic hinges were severely damaged due to spalling of concrete and rupture of the longitudinal and transverse reinforcement. Extensive post-test analytical studies were conducted and it was determined that a computational model of the bridge that included bridge-abutment interaction using OpenSees was able to provide satisfactory estimations of key structural parameters such as superstructure displacements and base shears. The analytical model was also used to conduct parametric studies on single-column and bridge-system response under near-fault ground motions. The effects of vertical excitations and transverse shear-keys at the bridge abutments on the superstructure displacement and column drifts were also explored.
Computational wing optimization and comparisons with experiment for a semi-span wing model
NASA Technical Reports Server (NTRS)
Waggoner, E. G.; Haney, H. P.; Ballhaus, W. F.
1978-01-01
A computational wing optimization procedure was developed and verified by an experimental investigation of a semi-span variable camber wing model in the NASA Ames Research Center 14 foot transonic wind tunnel. The Bailey-Ballhaus transonic potential flow analysis and Woodward-Carmichael linear theory codes were linked to Vanderplaats constrained minimization routine to optimize model configurations at several subsonic and transonic design points. The 35 deg swept wing is characterized by multi-segmented leading and trailing edge flaps whose hinge lines are swept relative to the leading and trailing edges of the wing. By varying deflection angles of the flap segments, camber and twist distribution can be optimized for different design conditions. Results indicate that numerical optimization can be both an effective and efficient design tool. The optimized configurations had as good or better lift to drag ratios at the design points as the best designs previously tested during an extensive parametric study.
NASA Technical Reports Server (NTRS)
Perez, Jose G.; Parks, Russel, A.; Lazor, Daniel R.
2012-01-01
The slosh dynamics of propellant tanks can be represented by an equivalent mass-pendulum-dashpot mechanical model. The parameters of this equivalent model, identified as slosh mechanical model parameters, are slosh frequency, slosh mass, and pendulum hinge point location. They can be obtained by both analysis and testing for discrete fill levels. Anti-slosh baffles are usually needed in propellant tanks to control the movement of the fluid inside the tank. Lateral slosh testing, involving both random excitation testing and free-decay testing, are performed to validate the slosh mechanical model parameters and the damping added to the fluid by the anti-slosh baffles. Traditional modal analysis procedures were used to extract the parameters from the experimental data. Test setup of sub-scale tanks will be described. A comparison between experimental results and analysis will be presented.
[Knee arthrodesis using a customized intramedullary nail: 14 cases].
Volpi, R; Dehoux, E; Touchard, P; Mensa, C; Segal, P
2004-02-01
We report our experience with knee arthrodesis using a customized intramedullary nail implanted in 14 patients. Indications for knee arthrodesis were: recurrent prosthesis infection (n=11), post-traumatic septic arthritis (n=1), aseptic loosening of a hinge prosthesis (n=1), and nonunion (n=1). A two-stage procedure was used for the 12 patients with infected joints. Mean follow-up was 19 months. Weight bearing began during the first week after arthrodesis in 13 patients. First intention bone healing was achieved in 13 patients. Mean time to healing was three months. All patients rapidly recovered full independence. Complications were: one misinsertion of the tibial stem, one nonunion which fused after repeated grafting, and two recurrent infections (controlled chronic fistulae) which required skin flaps for cover. We have found that this customized nail is a useful method for achieving bone fusion in patients with difficult indications for arthrodesis, particularly recurrent prosthesis infection.
Methods of comparing associative models and an application to retrospective revaluation.
Witnauer, James E; Hutchings, Ryan; Miller, Ralph R
2017-11-01
Contemporary theories of associative learning are increasingly complex, which necessitates the use of computational methods to reveal predictions of these models. We argue that comparisons across multiple models in terms of goodness of fit to empirical data from experiments often reveal more about the actual mechanisms of learning and behavior than do simulations of only a single model. Such comparisons are best made when the values of free parameters are discovered through some optimization procedure based on the specific data being fit (e.g., hill climbing), so that the comparisons hinge on the psychological mechanisms assumed by each model rather than being biased by using parameters that differ in quality across models with respect to the data being fit. Statistics like the Bayesian information criterion facilitate comparisons among models that have different numbers of free parameters. These issues are examined using retrospective revaluation data. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rostami, Ali Bakhshandeh; Fernandes, Antonio Carlos
2018-03-01
This paper is dedicated to develop a mathematical model that can simulate nonlinear phenomena of a hinged plate which places into the fluid flow (1 DOF). These phenomena are fluttering (oscillation motion), autorotation (continuous rotation) and chaotic motion (combination of fluttering and autorotation). Two mathematical models are developed for 1 DOF problem using two eminent mathematical models which had been proposed for falling plates (3 DOF). The procedures of developing these models are elaborated and then these results are compared to experimental data. The best model in the simulation of the phenomena is chosen for stability and bifurcation analysis. Based on these analyses, this model shows a transcritical bifurcation and as a result, the stability diagram and threshold are presented. Moreover, an analytical expression is given for finding the boundary of bifurcation from the fluttering to the autorotation.
Ars, Bernard; Dirckx, Joris
2016-10-01
The fibrocartilaginous eustachian tube is part of a system of contiguous organs including the nose, palate, rhinopharynx, and middle ear cleft. The middle ear cleft consists of the tympanic cavity, which includes the bony eustachian tube (protympanum) and the mastoid gas cells system. The tympanic cavity and mastoid gas cells are interconnected and allow gaseous exchange and pressure regulation. The fibrocartilaginous eustachian tube is a complex organ consisting of a dynamic conduit with its mucosa, cartilage, surrounding soft tissue, peritubal muscles (ie, tensor and levator veli palatine, salpingopharyngeus and tensor tympani), and superior bony support (the sphenoid sulcus). Copyright © 2016 Elsevier Inc. All rights reserved.
Functional anatomy of the levator palpebrae superioris muscle and its connective tissue system.
Ettl, A; Priglinger, S; Kramer, J; Koornneef, L
1996-01-01
AIMS/BACKGROUND: The connective tissue system of the levator palpebrae superioris muscle (LPS) consists of the septa surrounding its muscle sheath, the superior transverse ligament (STL) commonly referred to as 'Whitnall's ligament' and the common sheath which is the fascia between the LPS and the superior rectus muscle (SRM). The anterior band-like component of the common sheath is called transverse superior fascial expansion (TSFE) of the SRM and LPS. It mainly extends from the connective tissue of the trochlea to the fascia of the lacrimal gland. A detailed description of the relation between the LPS and its connective tissue is presented. Furthermore, the course of the LPS in the orbit is described. The study was conducted to provide a morphological basis for biomechanical and clinical considerations regarding ptosis surgery. METHODS: Postmortem dissections were performed in 16 orbits from eight cadavers. The microscopical anatomy was demonstrated in six formalin preserved orbits from six cadavers which had been sectioned in the frontal and sagittal plane and stained with haematoxylin and azophloxin. Surface coil magnetic resonance imaging in the sagittal and coronal plane was performed in five orbits from five normal volunteers using a T1 weighted spin echo sequence. RESULTS: The STL and the TSFE surround the LPS to form a fascial sleeve around the muscle which has attachments to the medial and lateral orbital wall. The TSFE, which is thicker than the STL, blends with Tenon's capsule. The STL and the fascial sheath of the LPS muscle are suspended from the orbital roof by a framework of radial connective tissue septa. MR images show that the TSFE is located between the anterior third of the superior rectus muscle and the segment of the LPS muscle where it changes its course from upwards to downwards. In this area, the LPS reaches its highest point in the orbit (culmination point). The culmination point is located a few millimetres posterior to the equator and superior to the globe. CONCLUSION: Whitnall's ligament can be considered to consist of two distinct parts--the TSFE inferior to the LPS and the STL superior to the LPS. Since the medial and lateral main attachments of Whitnall's ligament are situated inferior to the level of the culmination point of the LPS, the ligament itself is unlikely to suspend the levator muscle. However, a suspension of the LPS may be achieved by the radial connective tissue septa of the superior orbit. The TSFE in connection with the globe may have an additional supporting function. The elasticity of Whitnall's ligament and its connections with highly elastic structures including Tenon's capsule, may provide the morphological substrate for the previously proposed passive (that is, without orbicularis action) lowering of the lid during downward saccades. Images PMID:8949713
Arthrometric Evaluation of Stabilizing Effect of Knee Functional Bracing at Different Flexion Angles
Seyed Mohseni, Saeedeh; Moss, Farzam; Karimi, Hossein; Kamali, Mohammad
2009-01-01
Previous in-vivo investigations on the stabilizing efficacy of knee bracing for ACL reconstructed patients have been often limited to 20-30 degrees of knee flexion. In this study, the effectiveness of a uniaxial hinged functional brace to improve the knee stability was assessed at 30, 60 and 90 degrees of knee flexion. Arthrometry tests were conducted on 15 healthy subjects before and following wearing the brace and the tibial displacements were measured at up to 150 N anterior forces. Results indicated that functional bracing has a significant stabilizing effect throughout the range of knee flexion examined (p < 0.05). The rate of effectiveness, however, was not consistent across the flexion range, e.g., 50% at 30 degrees and only 4% at 90 degrees. It was suggested that accurate sizing and fitting as well as attention to correct hinge placement relative to the femoral condyles can limit brace migration and improve its effectiveness in mid and deep knee flexion. With using adaptive limb fittings, through flexible pads, and a polycentric joint a more significant improvement of the overall brace performance and efficacy might be obtained. Key points Functional bracing improves the knee joint stability mostly in extension posture. Unlike the non-braced condition, the least knee joint stability appears in mid and deep flexion angles when using a hinged brace. Accurate sizing and fitting and attention to correct hinge placement relative to the femoral condyles can limit brace migration and improve its effectiveness in mid and deep knee flexion. The overall brace performance and efficacy might be improved significantly using adaptive limb fittings through flexible pads and/or polycentric joints. PMID:24149533
Amerinatanzi, Amirhesam; Zamanian, Hashem; Shayesteh Moghaddam, Narges
2017-01-01
Hinge-based Ankle Foot Orthosis (HAFO) is one of the most common non-surgical solutions for the foot drop. In conventional HAFOs, the ankle joint is almost locked, and plantar flexion is restricted due to the high stiffness of the hinge mechanism. This often leads to a rigid walking gate cycle, poor muscle activity, and muscle atrophy. Since the ankle torque-angle loop has a non-linear profile, the use of a superelastic NiTi spring within the hinge, due to its nonlinear behavior, could recreate a close-to-normal stiffness of the normal ankle joint, which, in turn, could create a more natural walk. The focus of this study is to evaluate the performance of a superelastic NiTi spring versus a conventional Stainless Steel spring in a hinge mechanism of a custom-fit HAFO. To this aim, a custom-fit HAFO was fabricated via the fast casting technique. Then, motion analysis was performed for two healthy subjects (Case I and Case II): (i) subjects with bare foot; (ii) subjects wearing a conventional HAFO with no spring; (iii) subjects wearing a conventional Stainless Steel-based HAFO; and (iv) subjects wearing a NiTi spring-based HAFO. The data related to the ankle angle and the amount of moment applied to the ankle during walking were recorded using Cortex software and used for the evaluations. Finally, Finite Element Analysis (FEA) was performed to evaluate the safety of the designed HAFO. The NiTi spring offers a higher range of motion (7.9 versus 4.14 degree) and an increased level of moment (0.55 versus 0.36 N·m/kg). Furthermore, a NiTi spring offers an ankle torque-angle loop closer to that of the healthy subjects. PMID:29215571
Breed, Ananya A; Gomes, Amanda; Roy, Binita Sur; Mahale, Smita D; Pathak, Bhakti R
2013-04-01
Human Prostate Secretory Protein of 94 amino acids (PSP94) has been shown to bind human CRISP-3 (cysteine-rich secretory protein 3) with very high affinity. CRISP-3 belongs to the CRISP family of proteins having a PR-1 (pathogenesis related protein 1) domain at its N-terminal and ion channel regulatory (ICR) domain at its C-terminal connected by a hinge region. Functional significance of this complex is not yet known. In order to identify the residues and/or regions involved in PSP94-CRISP-3 interaction, site-directed mutagenesis was employed. Effect of the mutations on the interaction was studied by co-immunoprecipitation (Co-IP). For PSP94, amino acids Y(3), F(4), P(56) and the C-terminal β-strand were found to be crucial for interacting with CRISP-3. A disulfide bond between the two domains of PSP94 (C(37)A-C(73)A) was also important for this interaction. In case of CRISP-3, the N-terminal domain alone could not maintain a strong interaction with PSP94 but it required presence of the hinge region and not the C-terminal domain. Apart from CRISP-3, CRISP-2 was also found to interact with human PSP94. Based on our findings the most likely model of PSP94-CRISP-3 complex has been proposed. The terminal β-strands of PSP94 contact the first α-helix and the hinge region of CRISP-3. Involvement of the hinge region of CRISPs in interaction with PSP94 may affect the domain movement of CRISPs essential for the ion-channel regulatory activity resulting in inhibition of this activity. Copyright © 2013 Elsevier B.V. All rights reserved.
LASIK flap characteristics using the Moria M2 microkeratome with the 90-microm single use head.
Aslanides, Ioannis M; Tsiklis, Nikolaos S; Astyrakakis, Nikolaos I; Pallikaris, Ioannis G; Jankov, Mirko R
2007-01-01
To evaluate the accuracy and consistency of corneal flap thickness, horizontal diameter, and hinge size with the Moria M2 90-microm single use head. Fifty-two myopic patients (104 eyes), mean age 32.6 years, underwent bilateral LASIK with a superior hinged flap using the Moria M2 microkeratome (90-microm single use head). Prospective evaluation included flap thickness (subtraction method), diameter, hinge size, interface particles, intraoperative complications, and visual recovery. The mean preoperative spherical equivalent refraction was -5.72 +/- 2.59 diopters (D) (range: -2.88 to -10.75 D) and -5.84 +/- 2.73 D (range: -3.13 to -9.38 D) for right and left eyes, respectively. The mean preoperative central corneal thickness was 548 +/- 24 microm and 547 +/- 25 microm for right and left eyes, respectively. The mean preoperative steepest K was 44.12 +/- 1.28 D and 44.41 +/- 1.27 D for right and left eyes, respectively. Corneal diameter (white-to-white) was 12 +/- 0.4 mm and 11.9 +/- 0.4 mm for right and left eyes, respectively. The mean postoperative flap thickness was 109 +/- 18 microm (range: 67 to 152 microm) and 103 +/- 15 microm (range: 65 to 151 microm) for right and left eyes, respectively. The mean postoperative flap diameter was 9.4 +/- 0.3 mm (expected mean according to the nomogram given by the company was 9.5 mm). The mean postoperative hinge chord was 4.4 +/- 0.4 mm (expected mean 4.2 mm). No interface particles were detected on slit-lamp examination. The Moria M2 90-microm single use head is safe with reasonable predictability for LASIK flap creation.
Amerinatanzi, Amirhesam; Zamanian, Hashem; Shayesteh Moghaddam, Narges; Jahadakbar, Ahmadreza; Elahinia, Mohammad
2017-12-07
Hinge-based Ankle Foot Orthosis (HAFO) is one of the most common non-surgical solutions for the foot drop. In conventional HAFOs, the ankle joint is almost locked, and plantar flexion is restricted due to the high stiffness of the hinge mechanism. This often leads to a rigid walking gate cycle, poor muscle activity, and muscle atrophy. Since the ankle torque-angle loop has a non-linear profile, the use of a superelastic NiTi spring within the hinge, due to its nonlinear behavior, could recreate a close-to-normal stiffness of the normal ankle joint, which, in turn, could create a more natural walk. The focus of this study is to evaluate the performance of a superelastic NiTi spring versus a conventional Stainless Steel spring in a hinge mechanism of a custom-fit HAFO. To this aim, a custom-fit HAFO was fabricated via the fast casting technique. Then, motion analysis was performed for two healthy subjects (Case I and Case II): (i) subjects with bare foot; (ii) subjects wearing a conventional HAFO with no spring; (iii) subjects wearing a conventional Stainless Steel-based HAFO; and (iv) subjects wearing a NiTi spring-based HAFO. The data related to the ankle angle and the amount of moment applied to the ankle during walking were recorded using Cortex software and used for the evaluations. Finally, Finite Element Analysis (FEA) was performed to evaluate the safety of the designed HAFO. The NiTi spring offers a higher range of motion (7.9 versus 4.14 degree) and an increased level of moment (0.55 versus 0.36 N·m/kg). Furthermore, a NiTi spring offers an ankle torque-angle loop closer to that of the healthy subjects.
Hanes, Michael C; Weinzweig, Jeffrey; Kuzon, William M; Panter, Kip E; Buchman, Steven R; Faulkner, John A; Yu, Deborah; Cederna, Paul S; Larkin, Lisa M
2007-05-01
Analysis of the composition of muscle fibers constituent to a cleft palate could provide significant insight into the cause of velopharyngeal inadequacy. The authors hypothesized that levator veli palatini muscle dysfunction inherent to cleft palates could affect the timing and outcome of cleft palate repair. Single, permeabilized muscle fibers from levator veli palatini muscles of three normal (n = 19 fibers) and three chemically induced congenital cleft palates (n = 21 fibers) of 14-month-old goats were isolated, and contractile properties were evaluated. The maximum isometric force and rate constants of tension redevelopment (ktr) were measured, and the specific force and normalized power were calculated for each fiber. The ktr measures indicate that cleft fibers are predominantly fast-fatigable; normal fibers are slow fatigue-resistant: after a 10-minute isometric contraction, fibers from cleft palates had a loss of force 16 percent greater than that from normal palates (p = 0.0001). The cross-sectional areas of the fibers from cleft palates (2750 +/- 209 microm2) were greater (p = 0.05) than those from normal palates (2226 +/- 143 microm2). Specific forces did not differ between the two groups. Maximum normalized power of fibers from cleft palates (11.05 +/- 1.82 W/l) was greater (p = 0.0001) than fibers from normal palates (1.60 +/- 0.12 W/l). There are clear physiologic differences in single muscle fibers from cleft palates and normal palates: cleft palate fibers are physiologically fast, have greater fatigability, and have greater power production. Detection of functional and/or fiber type differences in muscles of cleft palates may provide preoperative identification of a patient's susceptibility to velopharyngeal inadequacy and permit early surgical intervention to correct this clinical condition.
Ophoff, Jill; Van Proeyen, Karen; Callewaert, Filip; De Gendt, Karel; De Bock, Katrien; Vanden Bosch, An; Verhoeven, Guido; Hespel, Peter; Vanderschueren, Dirk
2009-08-01
Muscle frailty is considered a major cause of disability in the elderly and chronically ill. However, the exact role of androgen receptor (AR) signaling in muscle remains unclear. Therefore, a postmitotic myocyte-specific AR knockout (mARKO) mouse model was created and investigated together with a mouse model with ubiquitous AR deletion. Muscles from mARKO mice displayed a marked reduction in AR protein (60-88%). Interestingly, body weights and lean body mass were lower in mARKO vs. control mice (-8%). The weight of the highly androgen-sensitive musculus levator ani was significantly reduced (-46%), whereas the weights of other peripheral skeletal muscles were not or only slightly reduced. mARKO mice had lower intra-abdominal fat but did not demonstrate a cortical or trabecular bone phenotype, indicating that selective ablation of the AR in myocytes affected male body composition but not skeletal homeostasis. Furthermore, muscle contractile performance in mARKO mice did not differ from their controls. Myocyte-specific AR ablation resulted in a conversion of fast toward slow fibers, without affecting muscle strength or fatigue. Similar results were obtained in ubiquitous AR deletion, showing lower body weight, whereas some but not all muscle weights were reduced. The percent slow fibers was increased, but no changes in muscle strength or fatigue could be detected. Together, our findings show that myocyte AR signaling contributes to the maintenance of muscle mass and fiber type regulation but not to muscle strength or fatigue. The levator ani weight remains the most sensitive and specific marker of AR-mediated anabolic action on muscle.
Lockhart, Mark E.; Bates, G. Wright; Morgan, Desiree E.; Beasley, Timothy M.; Richter, Holly E.
2017-01-01
Introduction and Hypothesis To prospectively characterize dynamic pelvic 3Tesla magnetic resonance imaging (dp3T MRI) findings in nulligravida women and characterize changes 6 months after delivery in the same woman. Methods In this prospective study, nulligravida women seeking assisted reproductive technology for pregnancy were recruited. After physical examination by Pelvic Organ Prolapse Quantification (POP-Q), Brinks assessment and measures including the Pelvic Floor Distress Inventory-20 and Pelvic Floor Impact Questionnaire-7, pre-pregnancy dp3T MRI at rest, with strain, and evacuation were performed. Assessments were repeated ≥6 months postpartum. Analysis included Welch and paired t-tests for continuous variables, Fisher’s Exact Test for differences in categorical outcomes, and paired t-tests for postpartum symptoms. Results Nineteen subjects (mean±SD age, 31±5 years) completed baseline clinical and dp3T MRI studies, 15 delivered and 10 (30.5±3 years) completed pre-pregnancy and post-delivery clinical and dp3T MRI assessments. There were no significant changes in scores of validated questionnaires (all p>0.05) or on POP-Q measures post-delivery. Two (20%) subjects without pre-pregnancy levator tears had tears on MRI post-delivery. MRI measures of pelvic organ descent were increased post-delivery. Seventeen pelvic soft tissue parameters increased by greater than 10% post-delivery including 5/70 (7.1%), 17/110 (15.5%), and 50/110 (45.5%) values exceeding thresholds at rest, strain, and evacuation, respectively. Conclusions Dynamic pelvic 3T Magnetic Resonance Imaging detected levator tears and increased pelvic organ descent, which can be directly attributed to pregnancy and delivery. PMID:28871385
Differences in Pelvic Morphology Between Women With and Without Provoked Vestibulodynia.
McLean, Linda; Thibault-Gagnon, Stephanie; Brooks, Kaylee; Goldfinger, Corrie; Pukall, Caroline; Chamberlain, Susan
2016-06-01
Pelvic morphology has been suggested to reflect increased tone and reduced strength of the pelvic floor muscles (PFMs) in women with provoked vestibulodynia (PVD) compared to healthy controls. We aimed to determine whether there are differences in pelvic morphology in the resting state, on maximum voluntary contraction (MVC), or on maximum effort Valsalva maneuver (MVM) between women with and without PVD. While imaged using ultrasound, 38 women with PVD and 39 controls relaxed their PFMs, performed 3 MVCs and performed 3 MVMs. Levator plate length (LPL), levator plate angle (LPA), and anorectal angle (ARA) were determined at rest, at MVC and at MVM. The displacement of the bladder neck (BN) on MVC and on MVM was also determined. Two-way ANCOVAs were used to evaluate the main effects of group and task, the interaction between group and task, and the effect of resting morphology on LPL, LPA, and ARA. A 2-way repeated-measures ANOVA was used to determine whether the groups differed in terms of BN displacement during the tasks. Women with PVD had smaller LPLs and LPAs than controls across all tasks. The significant group differences in LPL and LPA at MVC and MVM were no longer significant once the resting values were included as covariates in the models. Bladder neck displacement differed between the groups at MVM but not at MVC. Women with PVD display shorter LPL sand smaller LPAs than controls but their behavior does not differ when MVC and MVMs are performed. Our results do not support the hypothesis that women with PVD demonstrate abnormalities in PFM contractility on MVC or compliance on MVM. Copyright © 2016. Published by Elsevier Inc.
Outcome of triple-tendon transfer, an Eden-Lange variant, to reconstruct trapezius paralysis.
Elhassan, Bassem T; Wagner, Eric R
2015-08-01
This study describes the technique and evaluates the outcome of the triple-tendon (T3) transfer, an Eden-Lange variant, to the scapula to stabilize the scapulothoracic articulation in the treatment of symptomatic trapezius paralysis. T3 transfers were performed in 22 patients with a history of persistent trapezius paralysis secondary to spinal accessory nerve injury. The indications for surgery included shoulder pain and weakness and limited range of motion of the shoulder. The T3 transfer included transfer of the levator scapulae to the lateral aspect of the spine of the scapula, the rhomboid minor to the spine of the scapula just medial to the levator scapulae insertion, and the rhomboid major to the medial spine of the scapula, including all muscles bony insertions. At an average follow-up of 35 months, winging was corrected in all patients, with improvement of shoulder asymmetry. All patients had significant improvement of pain (P < .01) and range of motion, including active shoulder abduction that improved from an average of 71° preoperatively to 118° postoperatively (P < .02) and shoulder flexion from an average of 102° to 150° (P < .01). There were also significant improvements in aggregate Constant Shoulder Score (P < .01), subjective shoulder value (P < .01), and Disabilities of the Arm, Shoulder and Hand score (P < .01). All patients were very satisfied with the outcome of surgery. This study shows that the T3 transfer is effective in stabilizing the scapulothoracic articulation and restoring the function of the trapezius, and thus, in improving pain and shoulder function in patients with symptomatic trapezius paralysis. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Chevalier, Francine; Fernandez-Lao, Carolina; Cuesta-Vargas, Antonio Ignacio
2014-11-25
To describe the clinical, functional and quality of life characteristics in women with Stress Urinary Incontinence (SUI). In addition, to analyse the relationship between the variables reported by the patients and those informed by the clinicians, and the relationship between instrumented variables and the manual pelvic floor strength assessment. Two hundred and eighteen women participated in this observational, analytical study. An interview about Urinary Incontinence and the quality of life questionnaires (EuroQoL-5D and SF-12) were developed as outcomes reported by the patients. Manual muscle testing and perineometry as outcomes informed by the clinician were assessed. Descriptive and correlation analysis were carried out. The average age of the subjects was (39.93 ± 12.27 years), (24.49 ± 3.54 BMI). The strength evaluated by manual testing of the right levator ani muscles was 7.79 ± 2.88, the strength of left levator ani muscles was 7.51 ± 2.91 and the strength assessed with the perineometer was 7.64 ± 2.55. A positive correlation was found between manual muscle testing and perineometry of the pelvic floor muscles (p < .001). No correlation was found between outcomes of quality of life reported by the patients and outcomes of functional capacity informed by the physiotherapist. A stratification of the strength of pelvic floor muscles in a normal distribution of a large sample of women with SUI was done, which provided the clinic with a baseline. There is a relationship between the strength of the pelvic muscles assessed manually and that obtained by a perineometer in women with SUI. There was no relationship between these values of strength and quality of life perceived.
Matsuo, Kiyoshi; Ban, Ryokuya
2013-02-01
Proprioceptively innervated intramuscular connective tissues in Müller's muscle function as exterior mechanoreceptors to induce reflex contraction of the levator and occipitofrontalis muscles. In aponeurotic blepharoptosis, since the levator aponeurosis is disinserted from the tarsus, stretching of the mechanoreceptors in Müller's muscle is increased even on primary gaze to induce phasic and tonic reflexive contraction of the occipitofrontalis muscle. It was hypothesised that in certain patients with aponeurotic blepharoptosis, the presence of tonic reflexive contraction of the occipitofrontalis muscle due to the sensitised mechanoreceptors in Müller's muscle, can cause chronic tension-type headache (CTTH) associated with occipitofrontalis tenderness. To verify this hypothesis, this study evaluated (1) what differentiates patients with CTTH from patients without CTTH, (2) how pharmacological contraction of Müller's smooth muscle fibres as a method for desensitising the mechanoreceptors in Müller's muscle affects electromyographic activity of the frontalis muscle, and (3) how surgical aponeurotic reinsertion to desensitise the mechanoreceptors in Müller's muscle electromyographically or subjectively affects activities of the occipitofrontalis muscle or CTTH. It was found that patients had sustained CTTH when light eyelid closure did not markedly reduce eyebrow elevation. However, pharmacological contraction of Müller's smooth muscle fibres or surgery to desensitise the mechanoreceptor electromyographically reduced the tonic contraction of the occipitofrontalis muscle on primary gaze and subjectively relieved aponeurotic blepharoptosis-associated CTTH. Over-stretching of the mechanoreceptors in Müller's muscle on primary gaze may induce CTTH due to tonic reflexive contraction of the occipitofrontalis muscle. Therefore, surgical desensitisation of the mechanoreceptors in Müller's muscle appears to relieve CTTH.
Ban, Midori; Matsuo, Kiyoshi; Ban, Ryokuya; Yuzuriha, Shunsuke; Kaneko, Ai
2013-01-01
We have reported that a developed lower-positioned transverse ligament between the superior-medial orbital rim and the lateral orbital rim on the lateral horn in the lower orbital fat space antagonizes eyelid opening and folding in certain Japanese to produce narrow eye, no visible superior palpebral crease, and full eyelid. In this study, we confirmed relationship between development of the lower-positioned transverse ligament and presence of the superior palpebral crease. We evaluated whether (1) digital immobilization of eyebrow movement during eyelid opening and (2) a developed lower-positioned transverse ligament could classify Japanese subjects as being with or without visible superior palpebral crease. Digital immobilization of eyebrow movement restricted eyelid opening in all subjects without visible superior palpebral crease but did not restrict in any subject with visible superior palpebral crease. Macroscopic and microscopic evidence revealed that the lower-positioned transverse ligament behind the lower orbital septum in subjects without visible superior palpebral crease was significantly more developed than that in subjects with visible superior palpebral crease. Since a developed lower-positioned transverse ligament antagonizes opening and folding of the anterior lamella of the upper eyelid in subjects without visible superior palpebral crease, these individuals open their eyelids by lifting the eyebrow with the anterior lamella and the lower-positioned transverse ligament owing to increased tonic contraction of the frontalis muscle, in addition to the retractile force of the levator aponeurotic expansions. In subjects with visible superior palpebral crease, the undeveloped lower-positioned transverse ligament does not antagonize opening and folding of the anterior lamella, and so they open their eyelids by folding the anterior lamella on the superior palpebral crease via the retractile force of the levator aponeurotic expansions.
Ban, Ryokuya; Matsuo, Kiyoshi; Osada, Yoshiro; Ban, Midori; Yuzuriha, Shunsuke
2010-01-01
We have proposed a hypothetical mechanism to involuntarily sustain the effective eyelid retraction, which consists of not only voluntary but also reflexive contractions of the levator palpebrae superior muscle (LPSM). Voluntary contraction of fast-twitch fibres of the LPSM stretches the mechanoreceptors in Mueller's muscle to evoke trigeminal proprioception, which induces continuous reflexive contraction of slow-twitch fibres of the LPSM through the trigeminal proprioceptive nerve fibres innervating the mechanoreceptors in Mueller's muscle via the oculomotor neurons, as a tonic trigemino-oculomotor reflex. In the common skeletal mixed muscles, electrical stimulation of the proprioceptive nerve, which apparently connects the mechanoreceptors in muscle spindles to the motoneurons, induces the electromyographic response as the Hoffmann reflex. To verify the presence of the trigemino-oculomotor reflex, we confirmed whether intra-operative electrical simulation of the transverse trigeminal proprioceptive nerve on the proximal Mueller's muscle evokes an electromyographic response in the LPSM under general anaesthesia in 12 patients. An ipsilateral, phasic, short-latency response (latency: 2.8+/-0.3 ms) was induced in the ipsilateral LPSM in 10 of 12 subjects. As successful induction of the short-latency response in the ipsilateral LPSM corresponds to the Hoffmann reflex in the common skeletal mixed muscles, the present study is the first electromyographic verification of the presence of the monosynaptic trigemino-oculomotor reflex to induce reflexive contraction of the LPSM. The presence of the trigemino-oculomotor reflex may elucidate the unexplainable blepharoptosis due to surgery, trauma and tumour, all of which may damage the trigeminal proprioceptive nerve fibres to impair the trigemino-oculomotor reflex. Copyright (c) 2008. Published by Elsevier Ltd.
Ban, Midori; Matsuo, Kiyoshi; Ban, Ryokuya; Yuzuriha, Shunsuke; Kaneko, Ai
2013-01-01
Introduction: We have reported that a developed lower-positioned transverse ligament between the superior-medial orbital rim and the lateral orbital rim on the lateral horn in the lower orbital fat space antagonizes eyelid opening and folding in certain Japanese to produce narrow eye, no visible superior palpebral crease, and full eyelid. In this study, we confirmed relationship between development of the lower-positioned transverse ligament and presence of the superior palpebral crease. Methods: We evaluated whether (1) digital immobilization of eyebrow movement during eyelid opening and (2) a developed lower-positioned transverse ligament could classify Japanese subjects as being with or without visible superior palpebral crease. Results: Digital immobilization of eyebrow movement restricted eyelid opening in all subjects without visible superior palpebral crease but did not restrict in any subject with visible superior palpebral crease. Macroscopic and microscopic evidence revealed that the lower-positioned transverse ligament behind the lower orbital septum in subjects without visible superior palpebral crease was significantly more developed than that in subjects with visible superior palpebral crease. Conclusions: Since a developed lower-positioned transverse ligament antagonizes opening and folding of the anterior lamella of the upper eyelid in subjects without visible superior palpebral crease, these individuals open their eyelids by lifting the eyebrow with the anterior lamella and the lower-positioned transverse ligament owing to increased tonic contraction of the frontalis muscle, in addition to the retractile force of the levator aponeurotic expansions. In subjects with visible superior palpebral crease, the undeveloped lower-positioned transverse ligament does not antagonize opening and folding of the anterior lamella, and so they open their eyelids by folding the anterior lamella on the superior palpebral crease via the retractile force of the levator aponeurotic expansions. PMID:23943676
Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å
2016-06-01
To study the correlation between palpation, perineometry and transperineal ultrasound for assessment of pelvic floor muscle contraction and to define a contraction scale for ultrasound measurements. This was a cross-sectional study of 608 women examined with palpation of pelvic floor muscle contraction, using the Modified Oxford Scale, and measurement of the vaginal squeeze pressure with a vaginal balloon connected to a fiber-optic microtip transducer (perineometry). Transperineal ultrasound was used for measurements of levator hiatal area and anteroposterior (AP) diameter in the plane of minimal hiatal dimensions, at rest and on contraction. The pelvic floor muscle contraction was expressed as the percentage difference between values at rest and on contraction. Spearman's rank was used to test for correlation between the different methods of assessment. Significant correlations were found between all assessment methods (P < 0.001). Palpation correlated with perineometry (rs = 0.74) and with proportional change in hiatal area (rs = 0.67) and AP diameter (rs = 0.69) on ultrasound. Perineometry correlated with proportional change in hiatal area (rs = 0.60) and AP diameter (rs = 0.66) on ultrasound. We defined a contraction scale based on the proportional change in AP diameter. In this population, a change in AP diameter of < 7% corresponded to absence of contractions, 7-18% corresponded to weak contractions, 18-35% corresponded to normal contractions and > 35% corresponded to strong contractions. We found moderate to strong correlation between ultrasound measurements, palpation and perineometry for assessing pelvic floor muscle contraction. The proportional change in levator hiatal AP diameter was the ultrasound measurement with strongest correlation to palpation and perineometry and formed the basis for the contraction scale for ultrasound measurements. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Is Bariatric Surgery a Prophylaxis for Pelvic Floor Disorders?
Pomian, Andrzej; Majkusiak, Wojciech; Lisik, Wojciech; Tomasik, Paweł; Horosz, Edyta; Zwierzchowska, Aneta; Kociszewski, Jacek; Barcz, Ewa
2018-06-01
Obesity is one of the well-documented risk factors of pelvic floor disorders (PFDs). The PFDs include urinary and fecal incontinence (UI, FI) and pelvic organ prolapse (POP). Surgery-induced weight loss improves different kinds of incontinence as well as POP symptoms. However, there is a lack of evidence how bariatric surgery influences pelvic floor anatomy and function in women without previous PFDs and whether it may be concerned as PFD prophylaxis tool. The present analysis is a prospective, non-randomized case-control study from January 2014 to September 2017. Participants underwent pelvic floor ultrasound examination with bladder neck position estimation at rest, during levator ani tension, and at Valsalva maneuver before surgery and 12-18 months after. Pelvic organ prolapse quantification (POPQ) > 2 stage and PFD complaints were the exclusion criteria. Fifty-nine patients underwent bariatric surgery (57 sleeve gastrectomy and 2 gastric bypass). Mean BMI decreased from 43.8 ± 5.9 to 29 ± 4.6 kg/m 2 after surgery (p < 0.001). Statistically significant higher position of the bladder neck at rest, during tension, and at Valsalva maneuver (p < 0.05) was shown after surgery. We did not demonstrate differences in bladder neck mobility and bladder neck elevation at tension after weight loss. Bariatric surgery is associated with a betterment of bladder neck position at rest, tension, and Valsalva maneuver in women without PFDs. We postulate that bariatric surgery may be a tool for PFD prevention. It does not improve levator ani function and does not limit bladder neck mobility, which implicates that it has no influence on preexisting pelvic dysfunction.
Wlaźlak, Edyta; Surkont, Grzegorz; Shek, Ka L; Dietz, Hans P
2015-10-01
It has been claimed that urethral hypermobility and resting urethral pressure can largely explain stress incontinence in women. In this study we tried to replicate these findings in an unselected cohort of women seen for urodynamic testing, including as many potential confounders as possible. This study is a retrospective analysis of data obtained from 341 women. They attended for urodynamic testing due to symptoms of pelvic floor dysfunction. We excluded from the analysis women with a history of previous anti-incontinence and prolapse surgery. All patients had a standardised clinical assessment, 4D transperineal pelvic floor ultrasound and multichannel urodynamic testing. Urodynamic stress incontinence (USI) was diagnosed by multichannel urodynamic testing. Its severity was subjectively graded as mild, moderate and severe. Candidate variables were: age, BMI, symptoms of prolapse, vaginal parity, significant prolapse (compartment-specific), levator avulsion, levator hiatal area, Oxford grading, midurethral mobility, maximum urethral pressure (MUP), maximum cough pressure and maximum Valsalva pressure reached. On binary logistic regression, the following parameters were statistically significant in predicting urodynamic stress incontinence: age (P=0.03), significant rectocele (P=0.02), max. abdominal pressure reached (negatively, P<0.0001), midurethral mobility (P=0.0004) and MUP (negatively, P<0.0001). On multivariate analysis, accounting for multiple interdependencies, the following predictors remained significant: max. abdominal pressure reached (negatively, P<0.0001), cough pressure (P=0.006), midurethral mobility (P=0.003) and MUP (negatively, P<0.0001), giving an R(2) of 0.24. Mid-urethral mobility and MUP are the main predictors of USI. Demographic and clinical data are at best weak predictors. Our results suggest the presence of major unrecognised confounders. Copyright © 2015. Published by Elsevier Ireland Ltd.
Vajda, Eric G; López, Francisco J; Rix, Peter; Hill, Robert; Chen, Yanling; Lee, Kyoung-Jin; O'Brien, Z; Chang, William Y; Meglasson, Martin D; Lee, Yong-Hee
2009-02-01
Selective androgen receptor modulators (SARMs) are a new class of molecules in development to treat a variety of diseases. SARMs maintain the beneficial effects of androgens, including increased muscle mass and bone density, while having reduced activity on unwanted side effects. The mechanisms responsible for the tissue-selective activity of SARMs are not fully understood, and the pharmacokinetic (PK)/pharmacodynamic (PD) relationships are poorly described. Tissue-specific compound distribution potentially could be a mechanism responsible for apparent tissue selectivity. We examined the PK/PD relationship of a novel SARM, LGD-3303 [9-chloro-2-ethyl-1-methyl-3-(2,2,2-trifluoroethyl)-3H-pyrrolo[3,2-f]quinolin-7(6H)-one], in a castrated rat model of androgen deficiency. LGD-3303 has potent activity on levator ani muscle but is a partial agonist on the preputial gland and ventral prostate. LGD-3303 never stimulated ventral prostate above intact levels despite increasing plasma concentrations of compound. Tissue-selective activity was maintained when LGD-3303 was dosed orally or by continuous infusion, two routes of administration with markedly different time versus exposure profiles. Despite the greater muscle activity relative to prostate activity, local tissue concentrations of LGD-3303 were higher in the prostate than in the levator ani muscle. LGD-3303 has SARM properties that are independent of its pharmacokinetic profile, suggesting that the principle mechanism for tissue-selective activity is the result of altered molecular interactions at the level of the androgen receptor.
Nejishima, Hiroaki; Yamamoto, Noriko; Suzuki, Mika; Furuya, Kazuyuki; Nagata, Naoya; Yamada, Shizuo
2012-10-01
Selective androgen receptor modulators (SARMs) would provide alternative therapeutic agent for androgen-related diseases. We identified a tetrahydroquinoline (THQ) derivative, 1-(8-nitro-3a, 4, 5, 9b-tetrahydro-3H-cyclopenta[c]quinolin-4-yl) ethane-1, 2-diol (S-40542) as a novel SARM antagonist. Affinity for nuclear receptors of S-40542 was evaluated in receptor-binding studies. Androgen receptor (AR) transcriptional activity of S-40542 was investigated by luciferase reporter assay in DU145AR cells. Normal and benign prostatic hyperplasia (BPH) model rats were repeatedly treated with S-40542 and flutamide. The tissue weights of prostate and levator ani muscle as well as blood levels of testosterone and luteinizing hormone were measured. S-40542 bound to the AR with high affinity. S-40542 at relatively high concentrations increased the transcriptional activity. This agent also showed a concentration-dependent AR antagonistic action in the presence of 1 nM 5α-dihydrotestosterone. Repeated treatment with S-40542 and flutamide decreased dose-dependently the weights of the prostate to a similar extent. In contrast, the tissue weight-reducing effect by S-40542 treatment on the levator ani muscle was much weaker than that of flutamide. S-40542 had little effect on the blood level of testosterone and luteinizing hormone, whereas flutamide increased the level of both hormones. Furthermore, S-40542 decreased dose-dependently prostate weight of BPH rats. The current results indicate that S-40542 possesses the prostate-selective SARM activity, suggestive of clinical benefit against benign prostate hyperplasia. THQ compounds may be useful for the research of mode of action of SARMs and for the development of safe SARM antagonists. Copyright © 2012 Wiley Periodicals, Inc.
Siff, Lauren N; Hill, Audra J; Walters, Samantha J; Walters, Ginny; Walters, Mark D
2018-05-02
The aim oft his study was to compare the effects of 10 common exercises to traditional pelvic floor muscle (PFM) contractions (Kegel) on levator hiatus (LH) area and PFM length and strength. This is a cross-sectional study of 15 healthy postpartum women. Ten exercises were studied. These were common variations of leg, core, and back exercises used in yoga, Pilates, strength training, and physical therapy. Each participant performed all 10 exercises at a single visit in 2 examination settings: transperineal ultrasound and perineometry. Ultrasound measured the LH area and PFM length, and perineometry measured the muscle strength (peak squeeze pressure). Kegel generates an increase in squeeze pressure (24.3 cm H2O), shortens the muscles (-0.46 cm) and narrows the LH (-0.13 cm). The bird-dog and plank exercises were not different from Kegel in any measurement. While the leg-lift ultrasound dimensions are similar to Kegel, leg lifts generated peak squeeze pressures stronger than any other exercise (including Kegel). Whereas ultrasound dimensions were similar to Kegel, tucked and untucked squats and thigh adductions generated weaker contractions than Kegel. While crunch generated a squeeze pressure similar to Kegel, the ultrasound dimensions showed a significantly wider LH and longer muscle than Kegel. Bridge, clam, and plié exercises affected the PFMs differently than Kegel in all measures. Bird-dog, plank, and leg-lift exercises should be evaluated as alternative exercises to Kegel as they affect PFM strength and length and LH area similarly to Kegel, and leg lifts generate a stronger contraction than Kegel.
Wu, Yi; Dabhoiwala, Noshir F.; Hagoort, Jaco; Shan, Jin-Lu; Tan, Li-Wen; Fang, Bin-Ji; Zhang, Shao-Xiang; Lamers, Wouter H.
2015-01-01
Background Pelvic-floor anatomy is usually studied by artifact-prone dissection or imaging, which requires prior anatomical knowledge. We used the serial-section approach to settle contentious issues and an interactive 3D-pdf to make the results widely accessible. Method 3D reconstructions of undeformed thin serial anatomical sections of 4 females and 2 males (21–35y) of the Chinese Visible Human database. Findings Based on tendinous septa and muscle-fiber orientation as segmentation guides, the anal-sphincter complex (ASC) comprised the subcutaneous external anal sphincter (EAS) and the U-shaped puborectal muscle, a part of the levator ani muscle (LAM). The anococcygeal ligament fixed the EAS to the coccygeal bone. The puborectal-muscle loops, which define the levator hiatus, passed around the anorectal junction and inserted anteriorly on the perineal body and pubic bone. The LAM had a common anterior attachment to the pubic bone, but separated posteriorly into puborectal and “pubovisceral” muscles. This pubovisceral muscle was bilayered: its internal layer attached to the conjoint longitudinal muscle of the rectum and the rectococcygeal fascia, while its outer, patchy layer reinforced the inner layer. ASC contraction makes the ano-rectal bend more acute and lifts the pelvic floor. Extensions of the rectal longitudinal smooth muscle to the coccygeal bone (rectococcygeal muscle), perineal body (rectoperineal muscle), and endopelvic fascia (conjoint longitudinal and pubovisceral muscles) formed a “diaphragm” at the inferior boundary of the mesorectum that suspended the anorectal junction. Its contraction should straighten the anorectal bend. Conclusion The serial-section approach settled contentious topographic issues of the pelvic floor. We propose that the ASC is involved in continence and the rectal diaphragm in defecation. PMID:26305117
Deployable geodesic truss structure
NASA Technical Reports Server (NTRS)
Mikulas, Martin M., Jr. (Inventor); Rhodes, Marvin D. (Inventor); Simonton, J. Wayne (Inventor)
1987-01-01
A deployable geodesic truss structure which can be deployed from a stowed state to an erected state is described. The truss structure includes a series of bays, each bay having sets of battens connected by longitudinal cross members which give the bay its axial and torsional stiffness. The cross members are hinged at their mid point by a joint so that the cross members are foldable for deployment or collapsing. The bays are deployed and stabilized by actuator means connected between the mid point joints of the cross members. Hinged longerons may be provided to also connect the sets of battens and to collapse for stowing with the rest of the truss structure.
Effect of hinge-moment parameters on elevator stick forces in rapid maneuvers
NASA Technical Reports Server (NTRS)
Jones, R. T.; Greenberg, H.
1976-01-01
The importance of the stick force per unit normal acceleration as a criterion of longitudinal stability and the critical dependence of this gradient on elevator hinge moment parameters are investigated with special reference to transient effects for maneuvers of short duration. The analysis shows that different combinations of elevator parameters, which give the same stick force per unit acceleration in turns, give widely different force variations during the entries into and recoveries from steady turns and during maneuvers of short duration such as abrupt pull-ups. The stick force per unit acceleration is greater for abrupt than for gradual control movements.
Hot cell shield plug extraction apparatus
Knapp, Philip A.; Manhart, Larry K.
1995-01-01
An apparatus is provided for moving shielding plugs into and out of holes in concrete shielding walls in hot cells for handling radioactive materials without the use of external moving equipment. The apparatus provides a means whereby a shield plug is extracted from its hole and then swung approximately 90 degrees out of the way so that the hole may be accessed. The apparatus uses hinges to slide the plug in and out and to rotate it out of the way, the hinge apparatus also supporting the weight of the plug in all positions, with the load of the plug being transferred to a vertical wall by means of a bolting arrangement.
NASA Technical Reports Server (NTRS)
Hughes, T.
1974-01-01
Experimental aerodynamic investigations were conducted on a string-mounted 0.030 scale representation of the 140A/B space shuttle orbiter in the 7.75- by 11-foot low speed wind tunnel. The primary test objectives were to establish basic longitudinal and lateral directional stability and control characteristics for the basic configuration plus control surface hinge moments. Aerodynamic force and moment data were measured in the body axis system by an internally mounted, six-component strain gage balance. Additional configurations investigated were sealed rudder hingeline gaps, sealed elevon gaps and compartmentized speedbrakes.
Three-axis lever actuator with flexure hinges for an optical disk system
NASA Astrophysics Data System (ADS)
Han, Chang-Soo; Kim, Soo-Hyun
2002-10-01
A three-axis lever actuator with a flexure hinge has been designed and fabricated. This actuator is driven by electromagnetic force based on a coil-magnet system and can be used as a high precision actuator and, especially as a pickup head actuator in optical disks. High precision and low sensitivity to external vibration are the major advantages of this lever actuator. An analysis model was found and compared to the finite element method. Dynamic characteristics of the three-axis lever actuator were measured. The results are in very close agreement to those predicted by the model and finite element analysis.
Characterization of flexure hinges for the French watt balance experiment
NASA Astrophysics Data System (ADS)
Pinot, Patrick; Genevès, Gérard
2014-08-01
In the French watt balance experiment, the translation and rotation functions must have no backlash, no friction, nor the need for lubricants. In addition errors in position and movement must be below 100 nm. Flexure hinges can meet all of these criteria. Different materials, profile shapes and machining techniques have been studied. The flexure pivots have been characterized using three techniques: 1) an optical microscope and, if necessary, a SEM to observe the surface inhomogeneities; 2) a mass comparator to determine the bending stiffness of unloaded pivots; 3) a loaded beam oscillating freely under vacuum to study the dynamic behavior of loaded pivots.
Deployable Soft Composite Structures.
Wang, Wei; Rodrigue, Hugo; Ahn, Sung-Hoon
2016-02-19
Deployable structure composed of smart materials based actuators can reconcile its inherently conflicting requirements of low mass, good shape adaptability, and high load-bearing capability. This work describes the fabrication of deployable structures using smart soft composite actuators combining a soft matrix with variable stiffness properties and hinge-like movement through a rigid skeleton. The hinge actuator has the advantage of being simple to fabricate, inexpensive, lightweight and simple to actuate. This basic actuator can then be used to form modules capable of different types of deformations, which can then be assembled into deployable structures. The design of deployable structures is based on three principles: design of basic hinge actuators, assembly of modules and assembly of modules into large-scale deployable structures. Various deployable structures such as a segmented triangular mast, a planar structure comprised of single-loop hexagonal modules and a ring structure comprised of single-loop quadrilateral modules were designed and fabricated to verify this approach. Finally, a prototype for a deployable mirror was developed by attaching a foldable reflective membrane to the designed ring structure and its functionality was tested by using it to reflect sunlight onto to a small-scale solar panel.
Control-Structure Ratings on the Fox River at McHenry and Algonquin, Illinois
Straub, Timothy D.; Johnson, Gary P.; Hortness, Jon E.; Parker, Joseph R.
2009-01-01
The Illinois Department of Natural Resources-Office of Water Resources operates control structures on a reach of the Fox River in northeastern Illinois between McHenry and Algonquin. The structures maintain water levels in the river for flood-control and recreational purposes. This report documents flow ratings for hinged-crest gates, a broad-crested weir, sluice gates, and an ogee spillway on the control structures at McHenry and Algonquin. The ratings were determined by measuring headwater and tailwater stage along with streamflow at a wide range of flows at different gate openings. Standard control-structure rating techniques were used to rate each control structure. The control structures at McHenry consist of a 221-feet(ft)-long broad-crested weir, a 4-ft-wide fish ladder, a 50-ft-wide hinged-crest gate, five 13.75-ft-wide sluice gates, and a navigational lock. Sixty measurements were used to rate the McHenry structures. The control structures at Algonquin consist of a 242-ft-long ogee spillway and a 50-ft-wide hinged-crest gate. Forty-one measurements were used to rate the Algonquin control structures.