A Generalized-Compliant-Motion Primitive
NASA Technical Reports Server (NTRS)
Backes, Paul G.
1993-01-01
Computer program bridges gap between planning and execution of compliant robotic motions developed and installed in control system of telerobot. Called "generalized-compliant-motion primitive," one of several task-execution-primitive computer programs, which receives commands from higher-level task-planning programs and executes commands by generating required trajectories and applying appropriate control laws. Program comprises four parts corresponding to nominal motion, compliant motion, ending motion, and monitoring. Written in C language.
Lachance, Chantelle C; Jurkowski, Michal P; Dymarz, Ania C; Robinovitch, Stephen N; Feldman, Fabio; Laing, Andrew C; Mackey, Dawn C
2017-01-01
Compliant flooring, broadly defined as flooring systems or floor coverings with some level of shock absorbency, may reduce the incidence and severity of fall-related injuries in older adults; however, a lack of synthesized evidence may be limiting widespread uptake. Informed by the Arksey and O'Malley framework and guided by a Research Advisory Panel of knowledge users, we conducted a scoping review to answer: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries in healthcare settings? We searched academic and grey literature databases. Any record that discussed a compliant flooring system and at least one of biomechanical efficacy, clinical effectiveness, cost-effectiveness, or workplace safety was eligible for inclusion. Two independent reviewers screened and abstracted records, charted data, and summarized results. After screening 3611 titles and abstracts and 166 full-text articles, we included 84 records plus 56 companion (supplementary) reports. Biomechanical efficacy records (n = 50) demonstrate compliant flooring can reduce fall-related impact forces with minimal effects on standing and walking balance. Clinical effectiveness records (n = 20) suggest that compliant flooring may reduce injuries, but may increase risk for falls. Preliminary evidence suggests that compliant flooring may be a cost-effective strategy (n = 12), but may also result in increased physical demands for healthcare workers (n = 17). In summary, compliant flooring is a promising strategy for preventing fall-related injuries from a biomechanical perspective. Additional research is warranted to confirm whether compliant flooring (i) prevents fall-related injuries in real-world settings, (ii) is a cost-effective intervention strategy, and (iii) can be installed without negatively impacting workplace safety. Avenues for future research are provided, which will help to determine whether compliant flooring is recommended in healthcare environments.
Jurkowski, Michal P.; Dymarz, Ania C.; Robinovitch, Stephen N.; Feldman, Fabio; Laing, Andrew C.; Mackey, Dawn C.
2017-01-01
Background Compliant flooring, broadly defined as flooring systems or floor coverings with some level of shock absorbency, may reduce the incidence and severity of fall-related injuries in older adults; however, a lack of synthesized evidence may be limiting widespread uptake. Methods Informed by the Arksey and O’Malley framework and guided by a Research Advisory Panel of knowledge users, we conducted a scoping review to answer: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries in healthcare settings? We searched academic and grey literature databases. Any record that discussed a compliant flooring system and at least one of biomechanical efficacy, clinical effectiveness, cost-effectiveness, or workplace safety was eligible for inclusion. Two independent reviewers screened and abstracted records, charted data, and summarized results. Results After screening 3611 titles and abstracts and 166 full-text articles, we included 84 records plus 56 companion (supplementary) reports. Biomechanical efficacy records (n = 50) demonstrate compliant flooring can reduce fall-related impact forces with minimal effects on standing and walking balance. Clinical effectiveness records (n = 20) suggest that compliant flooring may reduce injuries, but may increase risk for falls. Preliminary evidence suggests that compliant flooring may be a cost-effective strategy (n = 12), but may also result in increased physical demands for healthcare workers (n = 17). Conclusions In summary, compliant flooring is a promising strategy for preventing fall-related injuries from a biomechanical perspective. Additional research is warranted to confirm whether compliant flooring (i) prevents fall-related injuries in real-world settings, (ii) is a cost-effective intervention strategy, and (iii) can be installed without negatively impacting workplace safety. Avenues for future research are provided, which will help to determine whether compliant flooring is recommended in healthcare environments. PMID:28166265
Dual-Arm Generalized Compliant Motion With Shared Control
NASA Technical Reports Server (NTRS)
Backes, Paul G.
1994-01-01
Dual-Arm Generalized Compliant Motion (DAGCM) primitive computer program implementing improved unified control scheme for two manipulator arms cooperating in task in which both grasp same object. Provides capabilities for autonomous, teleoperation, and shared control of two robot arms. Unifies cooperative dual-arm control with multi-sensor-based task control and makes complete task-control capability available to higher-level task-planning computer system via large set of input parameters used to describe desired force and position trajectories followed by manipulator arms. Some concepts discussed in "A Generalized-Compliant-Motion Primitive" (NPO-18134).
Hurrell, M J; Monk, T G; Nicol, A; Norton, A N; Reich, D L; Walsh, J L
2012-08-01
With the increasing use of anaesthesia information management systems (AIMS) there is the opportunity for different institutions to aggregate and share information both nationally and internationally. Potential uses of such aggregated data include outcomes research, benchmarking and improvement in clinical practice and patient safety. However, these goals can only be achieved if data contained in records from different sources are truly comparable and there is semantic inter-operability. This paper describes the development of a standard terminology for anaesthesia and also a Domain Analysis Model and implementation guide to facilitate a standard representation of AIMS records as extensible markup language documents that are compliant with the Health Level 7 Version 3 clinical document architecture. A representation of vital signs that is compliant with the International Standards Organization 11073 standard is also discussed.
Compliance among soft contact lens wearers.
Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko
2014-12-01
Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p < 0.0045 and t = -2.33, df= 48, p < 0.024, respectively). Our study indicates that almost all patients had some degree of non-compliance in lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.
A new approach of active compliance control via fuzzy logic control for multifingered robot hand
NASA Astrophysics Data System (ADS)
Jamil, M. F. A.; Jalani, J.; Ahmad, A.
2016-07-01
Safety is a vital issue in Human-Robot Interaction (HRI). In order to guarantee safety in HRI, a model reference impedance control can be a very useful approach introducing a compliant control. In particular, this paper establishes a fuzzy logic compliance control (i.e. active compliance control) to reduce impact and forces during physical interaction between humans/objects and robots. Exploiting a virtual mass-spring-damper system allows us to determine a desired compliant level by understanding the behavior of the model reference impedance control. The performance of fuzzy logic compliant control is tested in simulation for a robotic hand known as the RED Hand. The results show that the fuzzy logic is a feasible control approach, particularly to control position and to provide compliant control. In addition, the fuzzy logic control allows us to simplify the controller design process (i.e. avoid complex computation) when dealing with nonlinearities and uncertainties.
Kouchri, Farrokh Mohammadzadeh
2012-11-06
A Voice over Internet Protocol (VoIP) communications system, a method of managing a communications network in such a system and a program product therefore. The system/network includes an ENERGY STAR (E-star) aware softswitch and E-star compliant communications devices at system endpoints. The E-star aware softswitch allows E-star compliant communications devices to enter and remain in power saving mode. The E-star aware softswitch spools messages and forwards only selected messages (e.g., calls) to the devices in power saving mode. When the E-star compliant communications devices exit power saving mode, the E-star aware softswitch forwards spooled messages.
Compliant walking appears metabolically advantageous at extreme step lengths.
Kim, Jaehoon; Bertram, John E A
2018-05-19
Humans alter gait in response to unusual gait circumstances to accomplish the task of walking. For instance, subjects spontaneously increase leg compliance at a step length threshold as step length increases. Here we test the hypothesis that this transition occurs based on the level of energy expenditure, where compliant walking becomes less energetically demanding at long step lengths. To map and compare the metabolic cost of normal and compliant walking as step length increases. 10 healthy individuals walked on a treadmill using progressively increasing step lengths (100%, 120%, 140% and 160% of preferred step length), in both normal and compliant leg walking as energy expenditure was recorded via indirect calorimetry. Leg compliance was controlled by lowering the center-of-mass trajectory during stance, forcing the leg to flex and extend as the body moved over the foot contact. For normal step lengths, compliant leg walking was more costly than normal walking gait, but compliant leg walking energetic cost did not increase as rapidly for longer step lengths. This led to an intersection between normal and compliant walking cost curves at 114% relative step length (regression analysis; r 2 = 0.92 for normal walking; r 2 = 0.65 for compliant walking). Compliant leg walking is less energetically demanding at longer step lengths where a spontaneous shift to compliant walking has been observed, suggesting the human motor control system is sensitive to energetic requirements and will employ alternate movement patterns if advantageous strategies are available. The transition could be attributed to the interplay between (i) leg work controlling body travel during single stance and (ii) leg work to control energy loss in the step-to-step transition. Compliant leg walking requires more stance leg work at normal step lengths, but involves less energy loss at the step-to-step transition for very long steps. Copyright © 2018 Elsevier B.V. All rights reserved.
Using Changes in Binding Globulins to Assess Oral Contraceptive Compliance
Westhoff, Carolyn; Petrie, K.A.; Cremers, S.
2012-01-01
Background Validity of oral contraceptive pill (OCP) clinical trial results depends on participant compliance. Ethinyl estradiol (EE2) induces increases in hepatic binding globulin (BG) levels. Measuring these BG increases may provide an effective and convenient approach to distinguishing non-compliant from compliant OCP users in research settings. This analysis evaluated the usefulness of measuring increases in corticosteroid, sex hormone and thyroxine binding globulins (CBG, SHBG, TBG) as measures of OCP compliance. Methods We used frozen serum from a trial that compared ovarian suppression between normal weight and obese women randomized to one of two OCPs containing EE2 and levonorgestrel (LNG). Based on serial LNG measurements during the trial, 17% of participants were non-compliant. We matched non-compliant participants with compliant participants by age, BMI, ethnicity and OCP formulation. We measured CBG, SHBG and TBG levels, and compared change from baseline to 3-month follow-up between the non-compliant and compliant participants. Construction of receiver operator characteristic (ROC) curves allowed comparison of various BG measures. Results Changes in CBG and TBG distinguished OCP non-compliant users from compliant users (area under the ROC curve (AUROC), 0.86 and 0.89, p < 0.01). Changes in SHBG were less discriminating (AUROC 0.69) Conclusions EE2 induced increases in CBG and TBG provide a sensitive integrated marker of compliance with an LNG-containing OCP. PMID:22795088
SRG110 Stirling Generator Dynamic Simulator Vibration Test Results and Analysis Correlation
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Suarez, Vicente J.; Goodnight, Thomas W.; Callahan, John
2007-01-01
The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Stirling Radioisotope Generator (SRG110) for use as a power system for space science missions. The launch environment enveloping potential missions results in a random input spectrum that is significantly higher than historical radioisotope power system (RPS) launch levels and is a challenge for designers. Analysis presented in prior work predicted that tailoring the compliance at the generator-spacecraft interface reduced the dynamic response of the system thereby allowing higher launch load input levels and expanding the range of potential generator missions. To confirm analytical predictions, a dynamic simulator representing the generator structure, Stirling convertors and heat sources were designed and built for testing with and without a compliant interface. Finite element analysis was performed to guide the generator simulator and compliant interface design so that test modes and frequencies were representative of the SRG110 generator. This paper presents the dynamic simulator design, the test setup and methodology, test article modes and frequencies and dynamic responses, and post-test analysis results. With the compliant interface, component responses to an input environment exceeding the SRG110 qualification level spectrum were all within design allowables. Post-test analysis included finite element model tuning to match test frequencies and random response analysis using the test input spectrum. Analytical results were in good overall agreement with the test results and confirmed previous predictions that the SRG110 power system may be considered for a broad range of potential missions, including those with demanding launch environments.
Towards generating ECSS-compliant fault tree analysis results via ConcertoFLA
NASA Astrophysics Data System (ADS)
Gallina, B.; Haider, Z.; Carlsson, A.
2018-05-01
Attitude Control Systems (ACSs) maintain the orientation of the satellite in three-dimensional space. ACSs need to be engineered in compliance with ECSS standards and need to ensure a certain degree of dependability. Thus, dependability analysis is conducted at various levels and by using ECSS-compliant techniques. Fault Tree Analysis (FTA) is one of these techniques. FTA is being automated within various Model Driven Engineering (MDE)-based methodologies. The tool-supported CHESS-methodology is one of them. This methodology incorporates ConcertoFLA, a dependability analysis technique enabling failure behavior analysis and thus FTA-results generation. ConcertoFLA, however, similarly to other techniques, still belongs to the academic research niche. To promote this technique within the space industry, we apply it on an ACS and discuss about its multi-faceted potentialities in the context of ECSS-compliant engineering.
The tool extracts deep phenotypic information from the clinical narrative at the document-, episode-, and patient-level. The final output is FHIR compliant patient-level phenotypic summary which can be consumed by research warehouses or the DeepPhe native visualization tool.
Investigation of the Mechanical Performance of Compliant Thermal Barriers
NASA Technical Reports Server (NTRS)
DeMange, Jeffrey J.; Bott, Robert J.; Dunlap, Patrick H.
2011-01-01
Compliant thermal barriers play a pivotal role in the thermal protection systems of advanced aerospace vehicles. Both the thermal properties and mechanical performance of these barriers are critical in determining their successful implementation. Due to the custom nature of many thermal barriers, designers of advanced spacecraft have little guidance as to the design, selection, and implementation of these elements. As part of an effort to develop a more fundamental understanding of the interrelationship between thermal barrier design and performance, mechanical testing of thermal barriers was conducted. Two different types of thermal barriers with several core insulation density levels ranging from 62 to 141 kg/cu m were investigated. Room-temperature compression tests were conducted on samples to determine load performance and assess thermal barrier resiliency. Results showed that the loading behavior of these thermal barriers was similar to other porous, low-density, compliant materials, such as elastomeric foams. Additionally, the insulation density level had a significant non-linear impact on the stiffness and peak loads of the thermal barriers. In contrast, neither the thermal barrier type nor the level of insulation density significantly influenced the room-temperature resiliency of the samples.
SRG110 Stirling Generator Dynamic Simulator Vibration Test Results and Analysis Correlation
NASA Technical Reports Server (NTRS)
Suarez, Vicente J.; Lewandowski, Edward J.; Callahan, John
2006-01-01
The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Stirling Radioisotope Generator (SRG110) for use as a power system for space science missions. The launch environment enveloping potential missions results in a random input spectrum that is significantly higher than historical RPS launch levels and is a challenge for designers. Analysis presented in prior work predicted that tailoring the compliance at the generator-spacecraft interface reduced the dynamic response of the system thereby allowing higher launch load input levels and expanding the range of potential generator missions. To confirm analytical predictions, a dynamic simulator representing the generator structure, Stirling convertors and heat sources was designed and built for testing with and without a compliant interface. Finite element analysis was performed to guide the generator simulator and compliant interface design so that test modes and frequencies were representative of the SRG110 generator. This paper presents the dynamic simulator design, the test setup and methodology, test article modes and frequencies and dynamic responses, and post-test analysis results. With the compliant interface, component responses to an input environment exceeding the SRG110 qualification level spectrum were all within design allowables. Post-test analysis included finite element model tuning to match test frequencies and random response analysis using the test input spectrum. Analytical results were in good overall agreement with the test results and confirmed previous predictions that the SRG110 power system may be considered for a broad range of potential missions, including those with demanding launch environments.
Systems and Methods for Implementing Bulk Metallic Glass-Based Macroscale Compliant Mechanisms
NASA Technical Reports Server (NTRS)
Hofmann, Douglas C. (Inventor); Agnes, Gregory (Inventor)
2017-01-01
Systems and methods in accordance with embodiments of the invention implement bulk metallic glass-based macroscale compliant mechanisms. In one embodiment, a bulk metallic glass-based macroscale compliant mechanism includes: a flexible member that is strained during the normal operation of the compliant mechanism; where the flexible member has a thickness of 0.5 mm; where the flexible member comprises a bulk metallic glass-based material; and where the bulk metallic glass-based material can survive a fatigue test that includes 1000 cycles under a bending loading mode at an applied stress to ultimate strength ratio of 0.25.
Yang, Jiacheng; Durbin, Thomas D; Jiang, Yu; Tange, Takeshi; Karavalakis, Georgios; Cocker, David R; Johnson, Kent C
2018-05-31
The primary goal of this study was to compare emissions measurements between a 1065 compliant PEMS, and the NTK Compact Emissions Meter (NCEM) capable of measuring NOx, PM, and solid PN. Both units were equipped on a light-duty diesel truck and tested over local, highway, and downtown driving routes. The results indicate that the NOx measurements for the NCEM were within approximately ±10% of those the 1065 compliant PEMS, which suggests that the NCEM could be used as a screening tool for NOx emissions. The NCEM showed larger differences for PM emissions on an absolute level, but this was at PM levels well below the 1 mg/mi level. The NCEM differences ranged from -2% to +26% if the comparisons are based on a percentage of the 1.0 mg/mi standard. Larger differences were also seen for PN emissions, with the NCEM measuring higher PN emissions, which can primarily be attributed to a zero current offset that we observed for the NCEM, which has been subsequently improved in the latest generation of the NCEM system. The comparisons between the 1065 compliant PEMS and the NCEM suggest that there could be applications for the NCEM or other mini-PEMS for applications such as identification of potential issues by regulatory agencies, manufacturer evaluation and validation of emissions under in-use conditions, and potential use in inspection and maintenance (I/M) programs, especially for heavy-duty vehicles. Copyright © 2017. Published by Elsevier B.V.
Graduated driver license compliant teens involved in fatal motor vehicle crashes.
Pressley, Joyce C; Addison, Diane; Dawson, Patrick; Nelson, Sharifa S
2015-09-01
Significant reductions in motor vehicle injury mortality have been reported for teen drivers after passage of graduated driver licensing (GDL), seat belt, and no tolerance alcohol and drug laws. Despite this, teen drivers remain a vulnerable population with elevated fatal crash involvement. This study examines driver, vehicle, and crash characteristics of GDL-compliant, belted, and unimpaired teen drivers with the goal of identifying areas where further improvements might be realized. The Fatality Analysis Reporting System (FARS) for 2007 to 2009 was used to examine and classify driver violations/errors in compliant teen drivers (n = 1,571) of passenger vehicles involved in a fatal collision. Teens driving unbelted, non-GDL compliant, or impaired by alcohol or drugs were excluded. Statistical analysis used χ, Fisher's exact and multivariable logistic regression. Odds ratios are reported with 95% confidence intervals. Significance was defined as p < 0.05. Nearly one third (n = 1,571) of teen drivers involved in a fatal motor vehicle crash were GDL compliant, unimpaired, and belted. The majority held an intermediate GDL license (90.6%). Crash-related factors were identified for 63.1% of fatal crashes. Age- and sex-adjusted odds identified overcorrecting, speeding, lane errors, school morning crashes, distractions, and driving on slippery surfaces as having increased odds of fatality for the teen driver as well as newer vehicle models and heavier vehicle weight as protective. Among compliant drivers, weekday crashes before and after school and committing a driving violation at the time of crash were associated with increased risk of driver death and higher incidence of incapacitating injury in surviving drivers. Therapeutic study, level V.
Koh, Hong; Kim, Seung; Kim, Myung-Joon; Kim, Hyun Gi; Shin, Hyun Joo; Lee, Mi-Jung
2015-09-07
To evaluate the possibility of treatment effect monitoring using hepatic fat quantification magnetic resonance (MR) in pediatric nonalcoholic steatohepatitis (NASH). We retrospectively reviewed the medical records of patients who received educational recommendations and vitamin E for NASH and underwent hepatic fat quantification MR from 2011 to 2013. Hepatic fat fraction (%) was measured using dual- and triple-echo gradient-recalled-echo sequences at 3T. The compliant and non-compliant groups were compared clinically, biochemically, and radiologically. Twenty seven patients (M:F = 24:3; mean age: 12 ± 2.3 years) were included (compliant group = 22, non-compliant = 5). None of the baseline findings differed between the 2 groups, except for triglyceride level (compliant vs non-compliant, 167.7 mg/dL vs 74.2 mg/dL, P = 0.001). In the compliant group, high-density lipoprotein increased and all other parameters decreased after 1-year follow-up. However, there were various changes in the non-compliant group. Dual-echo fat fraction (-19.2% vs 4.6, P < 0.001), triple-echo fat fraction (-13.4% vs 3.5, P < 0.001), alanine aminotransferase (-110.7 IU/L vs -10.6 IU/L, P = 0.047), total cholesterol (-18.1 mg/dL vs 3.8 mg/dL, P = 0.016), and triglyceride levels (-61.3 mg/dL vs 11.2 mg/dL, P = 0.013) were significantly decreased only in the compliant group. The change in body mass index and dual-echo fat fraction showed a positive correlation (ρ = 0.418, P = 0.030). Hepatic fat quantification MR can be a non-invasive, quantitative and useful tool for monitoring treatment effects in pediatric NASH.
Gregory, Shaun D; Schummy, Emma; Pearcy, Mark; Pauls, Jo P; Tansley, Geoff; Fraser, John F; Timms, Daniel
2015-02-01
Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Parametric studies to determine the effect of compliant layers on metal matrix composite systems
NASA Technical Reports Server (NTRS)
Caruso, J. J.; Chamis, C. C.; Brown, H. C.
1990-01-01
Computational simulation studies are conducted to identify compliant layers to reduce matrix stresses which result from the coefficient of thermal expansion mismatch and the large temperature range over which the current metal matrix composites will be used. The present study includes variations of compliant layers and their properties to determine their influence on unidirectional composite and constituent response. Two simulation methods are used for these studies. The first approach is based on a three-dimensional linear finite element analysis of a 9 fiber unidirectional composite system. The second approach is a micromechanics based nonlinear computer code developed to determine the behavior of metal matrix composite system for thermal and mechanical loads. The results show that an effective compliant layer for the SCS 6 (SiC)/Ti-24Al-11Nb (Ti3Al + Nb) and SCS 6 (SiC)/Ti-15V-3Cr-3Sn-3Al (Ti-15-3) composite systems should have modulus 15 percent that of the matrix and a coefficient of thermal expansion of the compliant layer roughly equal to that of the composite system without the CL. The matrix stress in the longitudinal and the transverse tangent (loop) direction are tensile for the Ti3Al + Nb and Ti-15-3 composite systems upon cool down from fabrication. The fiber longitudinal stress is compressive from fabrication cool down. Addition of a recommended compliant layer will result in a reduction in the composite modulus.
Using Taxonomic Indexing Trees to Efficiently Retrieve SCORM-Compliant Documents in e-Learning Grids
ERIC Educational Resources Information Center
Shih, Wen-Chung; Tseng, Shian-Shyong; Yang, Chao-Tung
2008-01-01
With the flourishing development of e-Learning, more and more SCORM-compliant teaching materials are developed by institutes and individuals in different sites. In addition, the e-Learning grid is emerging as an infrastructure to enhance traditional e-Learning systems. Therefore, information retrieval schemes supporting SCORM-compliant documents…
10 CFR 2.1011 - Management of electronic information.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Management of electronic information. 2.1011 Section 2... High-Level Radioactive Waste at a Geologic Repository § 2.1011 Management of electronic information. (a... Language)-compliant (ANSI IX3.135-1992/ISO 9075-1992) database management system (DBMS). Alternatively, the...
NASA Technical Reports Server (NTRS)
Arnold, Steven M.; Arya, Vinod K.; Melis, Matthew E.
1990-01-01
High residual stresses within intermetallic and metal matrix composite systems can develop upon cooling from the processing temperature to room temperature due to the coefficient of thermal expansion (CTE) mismatch between the fiber and matrix. As a result, within certain composite systems, radial, circumferential, and/or longitudinal cracks have been observed to form at the fiber-matrix interface. The compliant layer concept (insertion of a compensating interface material between the fiber and matrix) was proposed to reduce or eliminate the residual stress buildup during cooling and thus minimize cracking. The viability of the proposed compliant layer concept is investigated both elastically and elastoplastically. A detailed parametric study was conducted using a unit cell model consisting of three concentric cylinders to determine the required character (i.e., thickness and material properties) of the compliant layer as well as its applicability. The unknown compliant layer mechanical properties were expressed as ratios of the corresponding temperature dependent Ti-24Al-11Nb (a/o) matrix properties. The fiber properties taken were those corresponding to SCS-6 (SiC). Results indicate that the compliant layer can be used to reduce, if not eliminate, radial and circumferential residual stresses within the fiber and matrix and therefore also reduce or eliminate the radial cracking. However, with this decrease in in-plane stresses, one obtains an increase in longitudinal stress, thus potentially initiating longitudinal cracking. Guidelines are given for the selection of a specific compliant material, given a perfectly bonded system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aurah, Mirwaise Y.; Roberts, Mark A.
Washington River Protection Solutions (WRPS), operator of High Level Radioactive Waste (HLW) Tank Farms at the Hanford Site, is taking an over 20-year leap in technology, replacing systems that were monitored with clipboards and obsolete computer systems, as well as solving major operations and maintenance hurdles in the area of process automation and information management. While WRPS is fully compliant with procedures and regulations, the current systems are not integrated and do not share data efficiently, hampering how information is obtained and managed.
JPL Space Telecommunications Radio System Operating Environment
NASA Technical Reports Server (NTRS)
Lux, James P.; Lang, Minh; Peters, Kenneth J.; Taylor, Gregory H.; Duncan, Courtney B.; Orozco, David S.; Stern, Ryan A.; Ahten, Earl R.; Girard, Mike
2013-01-01
A flight-qualified implementation of a Software Defined Radio (SDR) Operating Environment for the JPL-SDR built for the CoNNeCT Project has been developed. It is compliant with the NASA Space Telecommunications Radio System (STRS) Architecture Standard, and provides the software infrastructure for STRS compliant waveform applications. This software provides a standards-compliant abstracted view of the JPL-SDR hardware platform. It uses industry standard POSIX interfaces for most functions, as well as exposing the STRS API (Application Programming In terface) required by the standard. This software includes a standardized interface for IP components instantiated within a Xilinx FPGA (Field Programmable Gate Array). The software provides a standardized abstracted interface to platform resources such as data converters, file system, etc., which can be used by STRS standards conformant waveform applications. It provides a generic SDR operating environment with a much smaller resource footprint than similar products such as SCA (Software Communications Architecture) compliant implementations, or the DoD Joint Tactical Radio Systems (JTRS).
2014-01-01
Background There is controversy as to whether conservative management that includes wearing a brace and exercises is effective in stabilising idiopathic scoliosis curves. A brace only prevents progression of the curve and has been shown to have favourable outcomes when patients are compliant. So the aim of this study was to: determine the effect of compliance to the Rigo System Cheneau (RSC) brace and a specific exercise programme on Idiopathic Scoliosis curvature; and to compare the Quality of Life (QoL) and psychological traits of compliant and non compliant subjects. Methods A pre/post test study design was used with a post study comparison between subjects who complied with the management and those who did not. Fifty one subjects, girls aged 12-16 years, Cobb angles 20-50 degrees participated in the study. Subjects were divided into two groups, according to their compliance, at the end of the study. The compliant group wore the brace 20 or more hours a day and exercised three or more times per week. The non-compliant group wore the brace less than 20 hours a day and exercised less than three times per week. Cobb angles, vertebral rotation, scoliometer readings, peak flow, quality of life and personality traits were compared between groups, using the student’s two sample t-test and an analysis of covariance. Results The compliant group, wore the brace 21.5 hours per day and exercised four times a week, and significantly improved in all measures compared to non compliant subjects, who wore the brace 12 hours per day, exercised 1.7 times a week and significantly deteriorated (p < 0.0001). The major Cobb angles in the compliant group improved 10.19°(±5.5) and deteriorated 5.52°(±4.3) in the non compliant group (p < 0.0001). Compliant subjects had a significantly better QoL than the non compliant subjects (p = 0.001). The compliant group were significantly more emotionally mature, stable and realistic than the non compliant group (p = 0.03). Conclusions Good compliance of the RSC brace and a specific exercise regime resulted in a significant improvement in curvatures, poor compliance resulted in progression/deterioration. A poorer QoL in the non compliant group possibly was caused by personality traits of the group, being more emotionally immature and unstable. PMID:24926318
Turbine airfoil with dual wall formed from inner and outer layers separated by a compliant structure
Campbell,; Christian X. , Morrison; Jay, A [Oviedo, FL
2011-12-20
A turbine airfoil usable in a turbine engine with a cooling system and a compliant dual wall configuration configured to enable thermal expansion between inner and outer layers while eliminating stress formation is disclosed. The compliant dual wall configuration may be formed a dual wall formed from inner and outer layers separated by a compliant structure. The compliant structure may be configured such that the outer layer may thermally expand without limitation by the inner layer. The compliant structure may be formed from a plurality of pedestals positioned generally parallel with each other. The pedestals may include a first foot attached to a first end of the pedestal and extending in a first direction aligned with the outer layer, and may include a second foot attached to a second end of the pedestal and extending in a second direction aligned with the inner layer.
2000-10-01
control systems and prototyped the approach by porting the ILU ORB from Xerox to the Lynx real - time operating system . They then provided a distributed...compliant real - time operating system , a real-time ORB, and an ODMG-compliant real-time ODBMS [12]. The MITRE system is an infrastructure for...the server’s local operating system can handle. For instance, on a node controlled by the VXWorks real - time operating system with 256 local
2012-10-01
REPORT 3. DATES COVERED (From - To) MAR 2010 – APR 2012 4 . TITLE AND SUBTITLE IMPLICATIONS OF MULT-CORE ARCHITECTURES ON THE DEVELOPMENT OF...Framework for Multicore Information Flow Analysis ...................................... 23 4 4.1 A Hypothetical Reference Architecture... 4 Figure 2: Pentium II Block Diagram
2014-04-01
important data structures of RTEMS are introduced. Section 3.2.2 discusses the problems we found in RTEMS that may cause security vulnerabilities...the important data structures in RTEMS: Object, which is a critical data structure in the SCORE, tasks threads. Approved for Public Release...these important system codes. The example code shows a possibility that a user can delete a system thread. Therefore, in order to protect system
Herd protection effect of N95 respirators in healthcare workers.
Chen, Xin; Chughtai, Abrar Ahmad; MacIntyre, Chandini Raina
2017-12-01
Objective To determine if there was herd protection conferred to unprotected healthcare workers (HCWs) by N95 respirators worn by colleagues. Methods Data were analysed from a prospective cluster randomized clinical trial conducted in Beijing, China between 1 December 2008 and 15 January 2009. A minimum compliance level (MCL) of N95 respirators for prevention of clinical respiratory illness (CRI) was set based on various compliance cut-offs. The CRI rates were compared between compliant (≥MCL) and non-compliant (
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2016-09-01
The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.
Gregory, Shaun D; Stevens, Michael C; Pauls, Jo P; Schummy, Emma; Diab, Sara; Thomson, Bruce; Anderson, Ben; Tansley, Geoff; Salamonsen, Robert; Fraser, John F; Timms, Daniel
2016-09-01
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Knowledge Repository for Fmea Related Knowledge
NASA Astrophysics Data System (ADS)
Cândea, Gabriela Simona; Kifor, Claudiu Vasile; Cândea, Ciprian
2014-11-01
This paper presents innovative usage of knowledge system into Failure Mode and Effects Analysis (FMEA) process using the ontology to represent the knowledge. Knowledge system is built to serve multi-projects work that nowadays are in place in any manufacturing or services provider, and knowledge must be retained and reused at the company level and not only at project level. The system is following the FMEA methodology and the validation of the concept is compliant with the automotive industry standards published by Automotive Industry Action Group, and not only. Collaboration is assured trough web-based GUI that supports multiple users access at any time
Autovibration and chaotic motion of an unbalanced rotor in massive non-linear compliant supports
NASA Astrophysics Data System (ADS)
Pasynkova, I. A.; Stepanova, P. P.
2018-05-01
Stability loss scenarios of an unbalanced rotor with a flexible massless shaft mounted in massive non-linear compliant supports are studied on the example of cylindrical precession. Dyffing type of non-linearity in compliant supports is considered. The system "rotor - supports" has eight degrees of freedom. Internal and external friction are taken into account. Autovibrations and chaotic vibrations are obtained. The results are confirmed by numerical check.
HIPAA-compliant automatic monitoring system for RIS-integrated PACS operation
NASA Astrophysics Data System (ADS)
Jin, Jin; Zhang, Jianguo; Chen, Xiaomeng; Sun, Jianyong; Yang, Yuanyuan; Liang, Chenwen; Feng, Jie; Sheng, Liwei; Huang, H. K.
2006-03-01
As a governmental regulation, Health Insurance Portability and Accountability Act (HIPAA) was issued to protect the privacy of health information that identifies individuals who are living or deceased. HIPAA requires security services supporting implementation features: Access control; Audit controls; Authorization control; Data authentication; and Entity authentication. These controls, which proposed in HIPAA Security Standards, are Audit trails here. Audit trails can be used for surveillance purposes, to detect when interesting events might be happening that warrant further investigation. Or they can be used forensically, after the detection of a security breach, to determine what went wrong and who or what was at fault. In order to provide security control services and to achieve the high and continuous availability, we design the HIPAA-Compliant Automatic Monitoring System for RIS-Integrated PACS operation. The system consists of two parts: monitoring agents running in each PACS component computer and a Monitor Server running in a remote computer. Monitoring agents are deployed on all computer nodes in RIS-Integrated PACS system to collect the Audit trail messages defined by the Supplement 95 of the DICOM standard: Audit Trail Messages. Then the Monitor Server gathers all audit messages and processes them to provide security information in three levels: system resources, PACS/RIS applications, and users/patients data accessing. Now the RIS-Integrated PACS managers can monitor and control the entire RIS-Integrated PACS operation through web service provided by the Monitor Server. This paper presents the design of a HIPAA-compliant automatic monitoring system for RIS-Integrated PACS Operation, and gives the preliminary results performed by this monitoring system on a clinical RIS-integrated PACS.
Supporting Inclusion of At Risk Students in Secondary School through Positive Behaviour Support
ERIC Educational Resources Information Center
Hill, David; Brown, Don
2013-01-01
The retention of "at risk" students in secondary schools is a major challenge to inclusive education policy. Students with non-compliant behaviour at this level are typically dealt with by authoritarian and punitive disciplinary systems that frequently lead to exclusion from school. This paper reports on the successful establishment of a…
ISA-97 Compliant Architecture Testbed (ICAT) Projectry Organizations
1992-03-30
by the System Integracion Directorate of the USAISEC, August 29, 1992. The report discusses the refinement of the ISA-97 Compliant Architecture Model...browser and iconic representations of system objects and resources. When the user is interacting with an application which has multiple compo- nents, it is...computer communications, it is not uncommon for large information systems to be shared by users on multiple machines. The trend towards the desktop
2005-12-01
weapon system evaluation as a high-level architecture and distributed interactive simulation 6 compliant, human-in-the-loop, virtual environment...Directorate to participate in the Limited Early User Evaluation (LEUE) of the Common Avionics Architecture System (CAAS) cockpit. ARL conducted a human...CAAS, the UH-60M PO conducted a limited early user evaluation (LEUE) to evaluate the integration of the CAAS in the UH-60M crew station. The
Lowering the Barrier for Standards-Compliant and Discoverable Hydrological Data Publication
NASA Astrophysics Data System (ADS)
Kadlec, J.
2013-12-01
The growing need for sharing and integration of hydrological and climate data across multiple organizations has resulted in the development of distributed, services-based, standards-compliant hydrological data management and data hosting systems. The problem with these systems is complicated set-up and deployment. Many existing systems assume that the data publisher has remote-desktop access to a locally managed server and experience with computer network setup. For corporate websites, shared web hosting services with limited root access provide an inexpensive, dynamic web presence solution using the Linux, Apache, MySQL and PHP (LAMP) software stack. In this paper, we hypothesize that a webhosting service provides an optimal, low-cost solution for hydrological data hosting. We propose a software architecture of a standards-compliant, lightweight and easy-to-deploy hydrological data management system that can be deployed on the majority of existing shared internet webhosting services. The architecture and design is validated by developing Hydroserver Lite: a PHP and MySQL-based hydrological data hosting package that is fully standards-compliant and compatible with the Consortium of Universities for Advancement of Hydrologic Sciences (CUAHSI) hydrologic information system. It is already being used for management of field data collection by students of the McCall Outdoor Science School in Idaho. For testing, the Hydroserver Lite software has been installed on multiple different free and low-cost webhosting sites including Godaddy, Bluehost and 000webhost. The number of steps required to set-up the server is compared with the number of steps required to set-up other standards-compliant hydrologic data hosting systems including THREDDS, IstSOS and MapServer SOS.
ERIC Educational Resources Information Center
Minturn, Leigh; And Others
This document is Part II of an extensive cross-cultural project which investigated the socialization patterns of children into the compliance systems of society, and focuses upon aggressive behavior and compliant relationships, particularly in the school. Students were selected from comparable grade levels in six countries - Denmark, Greece,…
Risk aversion and compliance in markets for pollution control.
Stranlund, John K
2008-07-01
This paper examines the effects of risk aversion on compliance choices in markets for pollution control. A firm's decision to be compliant or not is independent of its manager's risk preference. However, non-compliant firms with risk-averse managers will have lower violations than otherwise identical firms with risk-neutral managers. The violations of non-compliant firms with risk-averse managers are independent of differences in their profit functions and their initial allocations of permits if and only if their managers' utility functions exhibit constant absolute risk aversion. However, firm-level characteristics do impact violation choices when managers have coefficients of absolute risk aversion that are increasing or decreasing in profit levels. Finally, in the equilibrium of a market for emissions rights with widespread non-compliance, risk aversion is associated with higher permit prices, better environmental quality, and lower aggregate violations.
Weber, Benedikt; Bachmann, Chantal C; Braun, Ralph; Abraham, Alison G; Serra, Andreas L; Hofbauer, Günther F L
2017-07-01
Regular use of sunbed exposure has been reported to increase 25-hydroxyvitamin-D3 [25(OH)D] serum levels. However, the influence of sunbeds compliant with the recent European Union standard EN-60335-2-27 on 25(OH)D serum levels is unknown. We investigated the impact of standard sunbed use compliant with the European Union standard on 25(OH)D serum modulation and well-being. In a randomized controlled study, 25(OH)D serum levels were measured at enrollment, after 1 week, and after completion of the 12-week period of sunbed use with twice weekly exposure and compared with the control group without any sunbed exposure. In the sunbed intervention group (N = 31), a 27% increase of mean 25(OH)D levels was noted 1 week after starting sunbed use (P < .01). However, after 12 weeks, mean 25(OH)D levels had declined and were no longer different from baseline (P = .06). After 12 weeks, 25(OH)D levels did not differ between the intervention and control group (P = .36). Also the 5-item World Health Organization Well-Being Index score did not differ between the sunbed and control groups (P = .19). For ethical reasons recruitment was limited to persons actively seeking sunbed exposure. Standard use of sunbeds compliant with the European Union standard induced a transient increase of 25(OH)D levels, whereas no change in well-being was observed. Copyright © 2017 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
Turbine airfoil with a compliant outer wall
Campbell, Christian X [Oviedo, FL; Morrison, Jay A [Oviedo, FL
2012-04-03
A turbine airfoil usable in a turbine engine with a cooling system and a compliant dual wall configuration configured to enable thermal expansion between inner and outer layers while eliminating stress formation in the outer layer is disclosed. The compliant dual wall configuration may be formed a dual wall formed from inner and outer layers separated by a support structure. The outer layer may be a compliant layer configured such that the outer layer may thermally expand and thereby reduce the stress within the outer layer. The outer layer may be formed from a nonplanar surface configured to thermally expand. In another embodiment, the outer layer may be planar and include a plurality of slots enabling unrestricted thermal expansion in a direction aligned with the outer layer.
Development of the Lymphoma Enterprise Architecture Database: a caBIG Silver level compliant system.
Huang, Taoying; Shenoy, Pareen J; Sinha, Rajni; Graiser, Michael; Bumpers, Kevin W; Flowers, Christopher R
2009-04-03
Lymphomas are the fifth most common cancer in United States with numerous histological subtypes. Integrating existing clinical information on lymphoma patients provides a platform for understanding biological variability in presentation and treatment response and aids development of novel therapies. We developed a cancer Biomedical Informatics Grid (caBIG) Silver level compliant lymphoma database, called the Lymphoma Enterprise Architecture Data-system (LEAD), which integrates the pathology, pharmacy, laboratory, cancer registry, clinical trials, and clinical data from institutional databases. We utilized the Cancer Common Ontological Representation Environment Software Development Kit (caCORE SDK) provided by National Cancer Institute's Center for Bioinformatics to establish the LEAD platform for data management. The caCORE SDK generated system utilizes an n-tier architecture with open Application Programming Interfaces, controlled vocabularies, and registered metadata to achieve semantic integration across multiple cancer databases. We demonstrated that the data elements and structures within LEAD could be used to manage clinical research data from phase 1 clinical trials, cohort studies, and registry data from the Surveillance Epidemiology and End Results database. This work provides a clear example of how semantic technologies from caBIG can be applied to support a wide range of clinical and research tasks, and integrate data from disparate systems into a single architecture. This illustrates the central importance of caBIG to the management of clinical and biological data.
Kamauu, Aaron W C; DuVall, Scott L; Wiggins, Richard H; Avrin, David E
2008-09-01
In the creation of interesting radiological cases in a digital teaching file, it is necessary to adjust the window and level settings of an image to effectively display the educational focus. The web-based applet described in this paper presents an effective solution for real-time window and level adjustments without leaving the picture archiving and communications system workstation. Optimized images are created, as user-defined parameters are passed between the applet and a servlet on the Health Insurance Portability and Accountability Act-compliant teaching file server.
Study of non-compliance among chronic hemodialysis patients and its impact on patients' outcomes.
Ibrahim, Salwa; Hossam, Mohammed; Belal, Dawlat
2015-03-01
Non-adherence to prescription is common among hemodialysis (HD) patients and has been associated with significant morbidity. At least 50% of HD patients are believed to be non-adherent to some part of their treatment. We aimed to assess the prevalence of non-adherence to dialysis prescription among 100 chronic HD patients. We explored the relationship between non-adherence on one hand and socioeconomic profile, depression scores and cognitive function on the other hand. The impact of patients' non-adherence on nutritional status, quality of life and dialysis adequacy was also assessed. The mean age of the study group was 50.51 ± 12.0 years. There were 62 females and 38 males in the study. Thirty-six patients (36%) were non-compliant to their dialysis prescription. No significant differences were detected between compliant and non-compliant patients in their education level and employment status. Inter-dialytic weight gain, serum phosphorus and depression scores were significantly higher in non-compliant patients compared with compliant patients, whereas body weight, serum albumin, serum calcium, quality of life scores and nutrition scores were significantly higher in compliant patients (P <0.05). In conclusion, non-adherence is highly prevalent among chronic HD patients and is associated with poor quality of life, depression and malnutrition.
NASA Technical Reports Server (NTRS)
Tesar, Delbert; Tosunoglu, Sabri; Lin, Shyng-Her
1990-01-01
Research results on general serial robotic manipulators modeled with structural compliances are presented. Two compliant manipulator modeling approaches, distributed and lumped parameter models, are used in this study. System dynamic equations for both compliant models are derived by using the first and second order influence coefficients. Also, the properties of compliant manipulator system dynamics are investigated. One of the properties, which is defined as inaccessibility of vibratory modes, is shown to display a distinct character associated with compliant manipulators. This property indicates the impact of robot geometry on the control of structural oscillations. Example studies are provided to illustrate the physical interpretation of inaccessibility of vibratory modes. Two types of controllers are designed for compliant manipulators modeled by either lumped or distributed parameter techniques. In order to maintain the generality of the results, neither linearization is introduced. Example simulations are given to demonstrate the controller performance. The second type controller is also built for general serial robot arms and is adaptive in nature which can estimate uncertain payload parameters on-line and simultaneously maintain trajectory tracking properties. The relation between manipulator motion tracking capability and convergence of parameter estimation properties is discussed through example case studies. The effect of control input update delays on adaptive controller performance is also studied.
ART OF THE POSSIBLE: SECURING AIR FORCE SPACE COMMAND MISSION SYSTEMS FOR THE WARFIGHTER
2016-10-23
Initiation (Adversarial)…….…17 Table 2. Assessment Scale-Likelihood of Threat Event Occurrence ( Non -Adversarial).17 Table 3. Assessment Scale...action to thwart the attacks from adversarial nation states and non -state actors alike. While there are numerous cybersecurity concerns, or non ...compliant cybersecurity controls across all weapon systems, not all non -compliant controls contribute equally to the cyber-attack surface and overall
Pärgmäe, P; Martins, N; Rodríguez, D; Christopoulos, P; Werner, H M J
2011-01-01
To review the compliance of the European Working Time Directive (EWTD) in different teaching hospitals across Europe and its consequences upon training. It is an observational, descriptive, cross-sectional study. The sample is constituted by the answers from trainees selected by the representatives of 29 European Network of Trainees in Ob/Gyn (ENTOG) member countries to a survey designed by ENTOG Executive. The survey content was based on a joint survey by the Royal College of Obstetricians and Gynaecologists (RCOG) and the Royal College for Paediatrics (RCP), carried out in 2008, but adapted for use on a European level. An answer rate of 75% was obtained. Only 5 countries out of 29 were compliant with EWTD two months before the compulsory adherence. Countries needed to introduce 1 to 4 changes to the system to make the rotas -compliant. Positive effect on work and private life balance was noticed in 87% from all responses. Trainees notice the need to further improve training programmes in order to have the same quality of training and continuous care of patients. Steps forward to implement EWTD are being made. Trainees should be involved with the introduction to optimize training conditions under the EWTD. Countries that still struggle to introduce the directive may learn from countries that already are compliant. It is suggested to organize a survey on senior society level to gain additional information to further investigate the effects on training quality and patient care.
Compliant displacement-multiplying apparatus for microelectromechanical systems
Kota, Sridhar; Rodgers, M. Steven; Hetrick, Joel A.
2001-01-01
A pivotless compliant structure is disclosed that can be used to increase the geometric advantage or mechanical advantage of a microelectromechanical (MEM) actuator such as an electrostatic comb actuator, a capacitive-plate electrostatic actuator, or a thermal actuator. The compliant structure, based on a combination of interconnected flexible beams and cross-beams formed of one or more layers of polysilicon or silicon nitride, can provide a geometric advantage of from about 5:1 to about 60:1 to multiply a 0.25-3 .mu.m displacement provided by a short-stroke actuator so that such an actuator can be used to generate a displacement stroke of about 10-34 .mu.m to operate a ratchet-driven MEM device or a microengine. The compliant structure has less play than conventional displacement-multiplying devices based on lever arms and pivoting joints, and is expected to be more reliable than such devices. The compliant structure and an associated electrostatic or thermal actuator can be formed on a common substrate (e.g. silicon) using surface micromachining.
Effect of Compliant Walls on Secondary Instabilities in Boundary-Layer Transition
NASA Technical Reports Server (NTRS)
Joslin, Ronald D.; Morris, Philip J.
1991-01-01
For aerodynamic and hydrodynamic vehicles, it is highly desirable to reduce drag and noise levels. A reduction in drag leads to fuel savings. In particular for submersible vehicles, a decrease in noise levels inhibits detection. A suggested means to obtain these reduction goals is by delaying the transition from laminar to turbulent flow in external boundary layers. For hydrodynamic applications, a passive device which shows promise for transition delays is the compliant coating. In previous studies with a simple mechanical model representing the compliant wall, coatings were found that provided transition delays as predicted from the semi-empirical e(sup n) method. Those studies were concerned with the linear stage of transition where the instability of concern is referred to as the primary instability. For the flat-plate boundary layer, the Tollmien-Schlichting (TS) wave is the primary instability. In one of those studies, it was shown that three-dimensional (3-D) primary instabilities, or oblique waves, could dominate transition over the coatings considered. From the primary instability, the stretching and tilting of vorticity in the shear flow leads to a secondary instability mechanism. This has been theoretical described by Herbert based on Floquet theory. In the present study, Herbert's theory is used to predict the development of secondary instabilities over isotropic and non-isotropic compliant walls. Since oblique waves may be dominant over compliant walls, a secondary theory extention is made to allow for these 3-D primary instabilities. The effect of variations in primary amplitude, spanwise wavenumber, and Reynolds number on the secondary instabilities are examined. As in the rigid wall case, over compliant walls the subharmonic mode of secondary instability dominates for low-amplitude primary disturbances. Both isotropic and non-isotropic compliant walls lead to reduced secondary growth rates compared to the rigid wall results. For high frequencies, the non-isotropic wall suppresses the amplification of the secondary instabilities, while instabilities over the isotropic wall may grow with an explosive rate similar to the rigid wall results. For the more important lower frequencies, both isotropic and non-isotropic compliant walls suppress the amplification of secondary instabilities compared to the rigid wall results. The twofold major discovery and demonstration of the present investigation are: (1) the use of passive devices, such as compliant walls, can lead to significant reductions in the secondary instability growth rates and amplification; (2) suppressing the primary growth rates and subsequent amplification enable delays in the growth of the explosive secondary instability mechanism.
Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C
2012-01-01
Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.
An Approach to Designing Passive Self-Leveling Landing Gear with Application to the Lunar Lander
NASA Technical Reports Server (NTRS)
Rippere, Troy B.; Wiens, Gloria J.
2010-01-01
Once the lunar lander has touched down on the moon problems can occur if the crew module is not level. To mitigate, compliant landing gear provide a solution that would allow the module to be leveled once it has landed on some ground slope. The work presented here uses compliant joints, or flexures, for each leg of the module and optimizes the mechanics of these flexures such that the module can be passively leveled over a range of landing slopes. Preliminary results suggest that for landing on a slope of up to 12 deg the effective slope of the module can be reduced to a maximum of 2.5 deg.
Bener, Abdulbari; Dafeeah, Elnour E; Salem, Mohamad O
2013-04-01
The aim of this study was to examine the extent of psychiatric patients' compliance and non-compliance with treatment and examine the factors that affect compliance. Patients were recruited who were between 16 and 60 years of age and who were hospitalized with a psychiatric disorder and treated in the outpatient clinics of the psychiatry department. A total of 689 patients were approached and 564 patients agreed to participate in the study, a response rate of 81.8%. Participants were asked to complete a questionnaire that asked about socio-demographic characteristics (e.g., age, gender, nationality, level of education, occupation, marital status, and life style habits); medication(s) prescribed and the participant's response; the degree of social supervision (rated subjectively by the patient as "poor," "good," or "very good"); data also were obtained from clinical records. Data analyses explored significant associations between compliance and non-compliance and a group of relevant variables. Of the 564 patients studied, 328 (58.2%) were compliant with treatment and 236 (41.8%) were non-compliant. There was no significant difference between compliance and non-compliance in terms of gender (p = 0.471). Patients between 21-30 years of age were significantly more compliant with drug treatment than not. Non-compliance was more common among patients diagnosed with schizophrenia (28.4%), followed by depression (14.4%), and bipolar affective disorder (12.7%) (p = 0.001). Only 25% of compliant patients and 26.3% of non-compliant patients used non-psychotropic medication. Social supervision (40%) was very poor in non-compliant patients whereas 49.4% of compliant patients had very good family support. Notable reasons for non-compliance were irregular attendance to clinic (55.5%), ignorance about side effects of medication (61%), free medicine (45.8%), and a lack of education about medication (58.1%). This study revealed that non-compliance rates among psychiatry patients were comparable to the rates reported in other studies. The findings suggest that there is a need to provide community-level mental health education and proper counseling to psychiatry patients.
Huang, Taoying; Shenoy, Pareen J.; Sinha, Rajni; Graiser, Michael; Bumpers, Kevin W.; Flowers, Christopher R.
2009-01-01
Lymphomas are the fifth most common cancer in United States with numerous histological subtypes. Integrating existing clinical information on lymphoma patients provides a platform for understanding biological variability in presentation and treatment response and aids development of novel therapies. We developed a cancer Biomedical Informatics Grid™ (caBIG™) Silver level compliant lymphoma database, called the Lymphoma Enterprise Architecture Data-system™ (LEAD™), which integrates the pathology, pharmacy, laboratory, cancer registry, clinical trials, and clinical data from institutional databases. We utilized the Cancer Common Ontological Representation Environment Software Development Kit (caCORE SDK) provided by National Cancer Institute’s Center for Bioinformatics to establish the LEAD™ platform for data management. The caCORE SDK generated system utilizes an n-tier architecture with open Application Programming Interfaces, controlled vocabularies, and registered metadata to achieve semantic integration across multiple cancer databases. We demonstrated that the data elements and structures within LEAD™ could be used to manage clinical research data from phase 1 clinical trials, cohort studies, and registry data from the Surveillance Epidemiology and End Results database. This work provides a clear example of how semantic technologies from caBIG™ can be applied to support a wide range of clinical and research tasks, and integrate data from disparate systems into a single architecture. This illustrates the central importance of caBIG™ to the management of clinical and biological data. PMID:19492074
Electromechanical acoustic liner
NASA Technical Reports Server (NTRS)
Sheplak, Mark (Inventor); Cattafesta, III, Louis N. (Inventor); Nishida, Toshikazu (Inventor); Horowitz, Stephen Brian (Inventor)
2007-01-01
A multi-resonator-based system responsive to acoustic waves includes at least two resonators, each including a bottom plate, side walls secured to the bottom plate, and a top plate disposed on top of the side walls. The top plate includes an orifice so that a portion of an incident acoustical wave compresses gas in the resonators. The bottom plate or the side walls include at least one compliant portion. A reciprocal electromechanical transducer coupled to the compliant portion of each of the resonators forms a first and second transducer/compliant composite. An electrical network is disposed between the reciprocal electromechanical transducer of the first and second resonator.
A Novel Model to Simulate Flexural Complements in Compliant Sensor Systems
Tang, Hongyan; Zhang, Dan; Guo, Sheng; Qu, Haibo
2018-01-01
The main challenge in analyzing compliant sensor systems is how to calculate the large deformation of flexural complements. Our study proposes a new model that is called the spline pseudo-rigid-body model (spline PRBM). It combines dynamic spline and the pseudo-rigid-body model (PRBM) to simulate the flexural complements. The axial deformations of flexural complements are modeled by using dynamic spline. This makes it possible to consider the nonlinear compliance of the system using four control points. Three rigid rods connected by two revolute (R) pins with two torsion springs replace the three lines connecting the four control points. The kinematic behavior of the system is described using Lagrange equations. Both the optimization and the numerical fitting methods are used for resolving the characteristic parameters of the new model. An example is given of a compliant mechanism to modify the accuracy of the model. The spline PRBM is important in expanding the applications of the PRBM to the design and simulation of flexural force sensors. PMID:29596377
Conwell, J L; Creek, K L; Pozzi, A R; Whyte, H M
2001-02-01
The Industrial Hygiene and Safety Group at Los Alamos National Laboratory (LANL) developed a database application known as IH DataView, which manages industrial hygiene monitoring data. IH DataView replaces a LANL legacy system, IHSD, that restricted user access to a single point of data entry needed enhancements that support new operational requirements, and was not Year 2000 (Y2K) compliant. IH DataView features a comprehensive suite of data collection and tracking capabilities. Through the use of Oracle database management and application development tools, the system is Y2K compliant and Web enabled for easy deployment and user access via the Internet. System accessibility is particularly important because LANL operations are spread over 43 square miles, and industrial hygienists (IHs) located across the laboratory will use the system. IH DataView shows promise of being useful in the future because it eliminates these problems. It has a flexible architecture and sophisticated capability to collect, track, and analyze data in easy-to-use form.
Klebanoff (K-) modes in boundary layers (BLs) over compliant surfaces
NASA Astrophysics Data System (ADS)
Ali, Reza; Carpenter, Peter
2002-11-01
We investigate the effect of wall compliance on K-modes. These are associated with streaks observed in the transitional BL, generated by spanwise modulation of the streamwise velocity, and are thought to be the mechanism for bypass transition. They have been widely studied over flat-plate, rigid surfaces but not compliant surfaces. A novel velocity-vorticity formulation is adopted for the numerical simulations, and a freestream spanwise body force is used to generate the streaks. We find compliant walls are less receptive than rigid walls, i.e. freestream turbulence generates weaker disturbances over compliant walls. This effect intensifies with increasing compliance. Where a compliant panel is embedded into a rigid surface, the leading and trailing edges of the panel can introduce a stabilising or destabilising disturbance on the streaks depending on the Reynolds number. It is therefore possible to optimise the wall to suppress streaks and hence bypass. K-modes can also act as a theoretical model for the near-wall structures that generate the high skin-friction drag in turbulent BLs. In this scenario, increasing compliance increases the spanwise spacing and weakens the streak. This explains experimental observations that wall compliance reduces skin-friction drag and turbulence levels in turbulent BLs.
NASA Astrophysics Data System (ADS)
Kuhlmann, Arne; Herd, Daniel; Röβler, Benjamin; Gallmann, Eva; Jungbluth, Thomas
In pig production software and electronic systems are widely used for process control and management. Unfortunately most devices on farms are proprietary solutions and autonomically working. To unify data communication of devices in agricultural husbandry, the international standard ISOagriNET (ISO 17532:2007) was developed. It defines data formats and exchange protocols, to link up devices like climate controls, feeding systems and sensors, but also management software. The aim of the research project, "Information and Data Collection in Livestock Systems" is to develop an ISOagriNET compliant IT system, a so called Farming Cell. It integrates all electronic components to acquire the available data and information for pig fattening. That way, an additional benefit to humans, animals and the environment regarding process control and documentation, can be generated. Developing the Farming Cell is very complex; in detail it is very difficult and long-winded to integrate hardware and software by various vendors into an ISOagriNET compliant IT system. This ISOagriNET prototype shows as a test environment the potential of this new standard.
Wright, Alexander D; Laing, Andrew C
2012-10-01
Novel compliant flooring systems are a promising approach for reducing fall-related injuries in seniors, as they may provide up to 50% attenuation in peak force during simulated hip impacts while eliciting only minimal influences on balance. This study aimed to determine the protective capacity of novel compliant floors during simulated 'high severity' head impacts compared to common flooring systems. A headform was impacted onto a common Commercial-Carpet at 1.5, 2.5, and 3.5 m/s in front, back, and side orientations using a mechanical drop tower. Peak impact force applied to the headform (F(max)), peak linear acceleration of the headform (g(max)) and Head Injury Criterion (HIC) were determined. For the 3.5 m/s trials, backwards-oriented impacts were associated with the highest F(max) and HIC values (p<0.001); accordingly, this head orientation was used to complete additional trials on three common floors (Resilient Rubber, Residential-Loop Carpet, Berber Carpet) and six novel compliant floors at each impact velocity. ANOVAs indicated that flooring type was associated with all parameters at each impact velocity (p<0.001). Compared to impacts on the Commercial Carpet, Dunnett's post hoc indicated all variables were smaller (25-80%) for the novel compliant floors (p<0.001), but larger for Resilient Rubber (31-159%, p<0.01). This study demonstrates that during 'high severity' simulated impacts, novel compliant floors can substantially reduce the forces and accelerations applied to a headform compared to common floors including carpet and resilient rubber. In combination with reports of minimal balance impairments, these findings support the promise of novel compliant floors as a biomechanically effective strategy for reducing fall-related injuries including traumatic brain injuries and skull fractures. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Materials for Adaptive Structural Acoustic Control. Volume 1
1993-04-06
FOLLOWING PAGE 14. SUBJECT TERMS 15. NUMBER OF PAGES 16. PRICE CODE 17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATION 19. SECURITY CLASSIFICATION 20...375 Rubber is a highly nonlinear clastic medium. In the unstressed compliant state, the molecules ate coiled and tangled . but under stress the molecules...one-dimensional system, \\\\here tangle (solid dots) and the oblique (open circle) states are the shaded area represents the level of thermal energy
Koçkaya, Güvenç; Wertheimer, Albert
2011-06-01
The current study was designed to calculate the direct cost of noncompliance of hypertensive patients to the US health system. Understanding these expenses can inform screening and education budget policy regarding expenditure levels that can be calculated to be cost-beneficial. The study was conducted in 3 parts. First, a computer search of National Institutes of Health Web sites and professional society Web sites for organizations with members that treat hypertension, and a PubMed search were performed to obtain the numbers required for calculations. Second, formulas were developed to estimate the risk of noncompliance and undiagnosed hypertension. Third, risk calculations were performed using the information obtained in part 1 and the formulas developed in part 2. Direct risk reduction for stroke caused by hypertension, heart attack, kidney disease, and heart disease was calculated for a 100% compliant strategy. Risk, case, and cost reduction for a 100% compliant strategy for hypertension were 32%, 8.5 million and US$ 72 billion, respectively. Our analysis means that the society can spend up to the cost of noncompliance in screening, education, and prevention efforts in an attempt to reduce these costly and traumatic sequelae of poorly controlled hypertension in the light of published analysis.
Certification Testing Approach for Propulsion System Design
NASA Technical Reports Server (NTRS)
Rodriguez, Henry; Popp, Chris
2005-01-01
The Certification of Propulsion Systems is costly and complex which involves development and qualification testing. The desire of the certification process is to assure all requirements can be demonstrated to be compliant. The purpose of this paper is to address the technical design concerns of certifying a system for flight. The authors of this paper have experience the lessons learned from supporting the Shuttle Program for Main Propulsion and On Orbit Propulsions Systems. They have collaborated design concerns for certifying propulsion systems. Presented are Pressurization, Tankage, Feed System and Combustion Instability concerns. Propulsion System Engineers are challenged with the dilemma for testing new systems to specific levels to reduce risk yet maintain budgetary targets. A methodical approach is presented to define the types of test suitable to address the technical issues for qualifying systems for retiring the risk levels.
Kinematic primitives for walking and trotting gaits of a quadruped robot with compliant legs.
Spröwitz, Alexander T; Ajallooeian, Mostafa; Tuleu, Alexandre; Ijspeert, Auke Jan
2014-01-01
In this work we research the role of body dynamics in the complexity of kinematic patterns in a quadruped robot with compliant legs. Two gait patterns, lateral sequence walk and trot, along with leg length control patterns of different complexity were implemented in a modular, feed-forward locomotion controller. The controller was tested on a small, quadruped robot with compliant, segmented leg design, and led to self-stable and self-stabilizing robot locomotion. In-air stepping and on-ground locomotion leg kinematics were recorded, and the number and shapes of motion primitives accounting for 95% of the variance of kinematic leg data were extracted. This revealed that kinematic patterns resulting from feed-forward control had a lower complexity (in-air stepping, 2-3 primitives) than kinematic patterns from on-ground locomotion (νm4 primitives), although both experiments applied identical motor patterns. The complexity of on-ground kinematic patterns had increased, through ground contact and mechanical entrainment. The complexity of observed kinematic on-ground data matches those reported from level-ground locomotion data of legged animals. Results indicate that a very low complexity of modular, rhythmic, feed-forward motor control is sufficient for level-ground locomotion in combination with passive compliant legged hardware.
Kinematic primitives for walking and trotting gaits of a quadruped robot with compliant legs
Spröwitz, Alexander T.; Ajallooeian, Mostafa; Tuleu, Alexandre; Ijspeert, Auke Jan
2014-01-01
In this work we research the role of body dynamics in the complexity of kinematic patterns in a quadruped robot with compliant legs. Two gait patterns, lateral sequence walk and trot, along with leg length control patterns of different complexity were implemented in a modular, feed-forward locomotion controller. The controller was tested on a small, quadruped robot with compliant, segmented leg design, and led to self-stable and self-stabilizing robot locomotion. In-air stepping and on-ground locomotion leg kinematics were recorded, and the number and shapes of motion primitives accounting for 95% of the variance of kinematic leg data were extracted. This revealed that kinematic patterns resulting from feed-forward control had a lower complexity (in-air stepping, 2–3 primitives) than kinematic patterns from on-ground locomotion (νm4 primitives), although both experiments applied identical motor patterns. The complexity of on-ground kinematic patterns had increased, through ground contact and mechanical entrainment. The complexity of observed kinematic on-ground data matches those reported from level-ground locomotion data of legged animals. Results indicate that a very low complexity of modular, rhythmic, feed-forward motor control is sufficient for level-ground locomotion in combination with passive compliant legged hardware. PMID:24639645
Integration of LDSE and LTVS logs with HIPAA compliant auditing system (HCAS)
NASA Astrophysics Data System (ADS)
Zhou, Zheng; Liu, Brent J.; Huang, H. K.; Guo, Bing; Documet, Jorge; King, Nelson
2006-03-01
The deadline of HIPAA (Health Insurance Portability and Accountability Act) Security Rules has passed on February 2005; therefore being HIPAA compliant becomes extremely critical to healthcare providers. HIPAA mandates healthcare providers to protect the privacy and integrity of the health data and have the ability to demonstrate examples of mechanisms that can be used to accomplish this task. It is also required that a healthcare institution must be able to provide audit trails on image data access on demand for a specific patient. For these reasons, we have developed a HIPAA compliant auditing system (HCAS) for image data security in a PACS by auditing every image data access. The HCAS was presented in 2005 SPIE. This year, two new components, LDSE (Lossless Digital Signature Embedding) and LTVS (Patient Location Tracking and Verification System) logs, have been added to the HCAS. The LDSE can assure medical image integrity in a PACS, while the LTVS can provide access control for a PACS by creating a security zone in the clinical environment. By integrating the LDSE and LTVS logs with the HCAS, the privacy and integrity of image data can be audited as well. Thus, a PACS with the HCAS installed can become HIPAA compliant in image data privacy and integrity, access control, and audit control.
Contreras-Manzano, Alejandra; Jáuregui, Alejandra; Velasco-Bernal, Anabel; Vargas-Meza, Jorge; Rivera, Juan A; Tolentino-Mayo, Lizbeth; Barquera, Simón
2018-06-07
Nutrient profiling systems (NPS) are used around the world. In some countries, the food industry participates in the design of these systems. We aimed to compare the ability of various NPS to identify processed and ultra-processed Mexican products containing excessive amounts of critical nutrients. A sample of 2544 foods and beverages available in the Mexican market were classified as compliant and non-compliant according to seven NPS: the Pan American Health Organization (PAHO) model, which served as our reference, the Nutrient Profiling Scoring Criterion (NPSC), the Mexican Committee of Nutrition Experts (MCNE), the Health Star Rating (HSR), the Mexican Nutritional Seal (MNS), the Chilean Warning Octagons (CWO) 2016, 2018 and 2019 criteria, and Ecuador's Multiple Traffic Light (MTL). Overall, the proportion of foods classified as compliant by the HSR, MTL and MCNE models was similar to the PAHO model. In contrast, the NPSC, the MNS and the CWO-2016 classified a higher amount of foods as compliant. Larger differences between NPS classification were observed across food categories. Results support the notion that models developed with the involvement of food manufacturers are more permissive than those based on scientific evidence. Results highlight the importance of thoroughly evaluating the underlying criteria of a model.
Kaliki, Swathi; Patel, Anamika; Iram, Sadiya; Palkonda, Vijay Anand Reddy
2017-05-01
To describe the clinical features and outcomes of patients with stage III or IV retinoblastoma. This was a retrospective study of 80 patients. Based on the International Retinoblastoma Staging System (IRSS), the tumors (n = 81) belonged to stage IIIa (n = 38, 47%), IIIb (n = 1, 1%), IVa2 (n = 10, 12%), IVb1 (n = 14, 17%), and IVb3 (n = 18, 22%). Of 80 patients, 42 (53%) were compliant to treatment and 38 (47%) were non-compliant. All 38 patients who were non-compliant to treatment died of the disease at a mean duration of 13 months from diagnosis. Of the 42 patients compliant to treatment, 22 (52%) died before completion of treatment. Twenty patients with stage III disease (25%) could complete the multimodal treatment and 17 (71%) were alive and well at a median follow-up duration of 77 months. Compliant multimodality treatment is beneficial in patients with IRSS stage III disease. IRSS stage IV retinoblastoma has poor prognosis despite treatment. [J Pediatr Ophthalmol Strabismus. 2017;54(3):177-184.]. Copyright 2017, SLACK Incorporated.
7 CFR 1753.6 - Standards, specifications, and general requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... compliant, as defined in 7 CFR 1735.22(e). (d) All materials and equipment financed with loan funds are subject to the “Buy American” provision (7 U.S.C. 901 et seq. as amended in 1938). (e) All software, software systems, and firmware financed with loan funds must be year 2000 compliant, as defined in 7 CFR...
7 CFR 1753.6 - Standards, specifications, and general requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... compliant, as defined in 7 CFR 1735.22(e). (d) All materials and equipment financed with loan funds are subject to the “Buy American” provision (7 U.S.C. 901 et seq. as amended in 1938). (e) All software, software systems, and firmware financed with loan funds must be year 2000 compliant, as defined in 7 CFR...
7 CFR 1753.6 - Standards, specifications, and general requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... compliant, as defined in 7 CFR 1735.22(e). (d) All materials and equipment financed with loan funds are subject to the “Buy American” provision (7 U.S.C. 901 et seq. as amended in 1938). (e) All software, software systems, and firmware financed with loan funds must be year 2000 compliant, as defined in 7 CFR...
7 CFR 1753.6 - Standards, specifications, and general requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... compliant, as defined in 7 CFR 1735.22(e). (d) All materials and equipment financed with loan funds are subject to the “Buy American” provision (7 U.S.C. 901 et seq. as amended in 1938). (e) All software, software systems, and firmware financed with loan funds must be year 2000 compliant, as defined in 7 CFR...
Reconfigurable, Intelligently-Adaptive, Communication System, an SDR Platform
NASA Technical Reports Server (NTRS)
Roche, Rigoberto
2016-01-01
The Space Telecommunications Radio System (STRS) provides a common, consistent framework to abstract the application software from the radio platform hardware. STRS aims to reduce the cost and risk of using complex, configurable and reprogrammable radio systems across NASA missions. The Glenn Research Center (GRC) team made a software-defined radio (SDR) platform STRS compliant by adding an STRS operating environment and a field programmable gate array (FPGA) wrapper, capable of implementing each of the platforms interfaces, as well as a test waveform to exercise those interfaces. This effort serves to provide a framework toward waveform development on an STRS compliant platform to support future space communication systems for advanced exploration missions. Validated STRS compliant applications provided tested code with extensive documentation to potentially reduce risk, cost and efforts in development of space-deployable SDRs. This paper discusses the advantages of STRS, the integration of STRS onto a Reconfigurable, Intelligently-Adaptive, Communication System (RIACS) SDR platform, the sample waveform, and wrapper development efforts. The paper emphasizes the infusion of the STRS Architecture onto the RIACS platform for potential use in next generation SDRs for advance exploration missions.
Tyl, Rochelle W.
2009-01-01
Background Myers et al. [Environ Health Perspect 117:309–315 (2009)] argued that Good Laboratory Practices (GLPs) cannot be used as a criterion for selecting data for risk assessment, using bisphenol A (BPA) as a case study. They did not discuss the role(s) of guideline-compliant studies versus basic/exploratory research studies, and they criticized both GLPs and guideline-compliant studies and their roles in formal hazard evaluation and risk assessment. They also specifically criticized our published guideline-compliant dietary studies on BPA in rats and mice and 17β-estradiol (E2) in mice. Objectives As the study director/first author of the criticized E2 and BPA studies, I discuss the uses of basic research versus guideline-compliant studies, how testing guidelines are developed and revised, how new end points are validated, and the role of GLPs. I also provide an overview of the BPA guideline-compliant and exploratory research animal studies and describe BPA pharmacokinetics in rats and humans. I present responses to specific criticisms by Myers et al. Discussion and conclusions Weight-of-evidence evaluations have consistently concluded that low-level BPA oral exposures do not adversely affect human developmental or reproductive health, and I encourage increased validation efforts for “new” end points for inclusion in guideline studies, as well as performance of robust long-term studies to follow early effects (observed in small exploratory studies) to any adverse consequences. PMID:20049112
A Smartwatch-Driven Medication Management System Compliant to the German Medication Plan.
Keil, Andreas; Gegier, Konstantin; Pobiruchin, Monika; Wiesner, Martin
2016-01-01
Medication adherence is an important factor for the outcome of medical therapies. To support high adherence levels, smartwatches can be used to assist the patient. However, a successful integration of such devices into clinicians' or general practitioners' information systems requires the use of standards. In this paper, a medication management system supplied with smartwatch generated feedback events is presented. It allows physicians to manage their patients' medications and track their adherence in real time. Moreover, it fosters interoperability via a ISO/IEC 16022 data matrix which encodes related medication data in compliance with the German Medication Plan specification.
Validation of an automated system for aliquoting of HIV-1 Env-pseudotyped virus stocks.
Schultz, Anke; Germann, Anja; Fuss, Martina; Sarzotti-Kelsoe, Marcella; Ozaki, Daniel A; Montefiori, David C; Zimmermann, Heiko; von Briesen, Hagen
2018-01-01
The standardized assessments of HIV-specific immune responses are of main interest in the preclinical and clinical stage of HIV-1 vaccine development. In this regard, HIV-1 Env-pseudotyped viruses play a central role for the evaluation of neutralizing antibody profiles and are produced according to Good Clinical Laboratory Practice- (GCLP-) compliant manual and automated procedures. To further improve and complete the automated production cycle an automated system for aliquoting HIV-1 pseudovirus stocks has been implemented. The automation platform consists of a modified Tecan-based system including a robot platform for handling racks containing 48 cryovials, a Decapper, a tubing pump and a safety device consisting of ultrasound sensors for online liquid level detection of each individual cryovial. With the aim to aliquot the HIV-1 pseudoviruses in an automated manner under GCLP-compliant conditions a validation plan was developed where the acceptance criteria-accuracy, precision as well as the specificity and robustness-were defined and summarized. By passing the validation experiments described in this article the automated system for aliquoting has been successfully validated. This allows the standardized and operator independent distribution of small-scale and bulk amounts of HIV-1 pseudovirus stocks with a precise and reproducible outcome to support upcoming clinical vaccine trials.
Validation of an automated system for aliquoting of HIV-1 Env-pseudotyped virus stocks
Schultz, Anke; Germann, Anja; Fuss, Martina; Sarzotti-Kelsoe, Marcella; Ozaki, Daniel A.; Montefiori, David C.; Zimmermann, Heiko
2018-01-01
The standardized assessments of HIV-specific immune responses are of main interest in the preclinical and clinical stage of HIV-1 vaccine development. In this regard, HIV-1 Env-pseudotyped viruses play a central role for the evaluation of neutralizing antibody profiles and are produced according to Good Clinical Laboratory Practice- (GCLP-) compliant manual and automated procedures. To further improve and complete the automated production cycle an automated system for aliquoting HIV-1 pseudovirus stocks has been implemented. The automation platform consists of a modified Tecan-based system including a robot platform for handling racks containing 48 cryovials, a Decapper, a tubing pump and a safety device consisting of ultrasound sensors for online liquid level detection of each individual cryovial. With the aim to aliquot the HIV-1 pseudoviruses in an automated manner under GCLP-compliant conditions a validation plan was developed where the acceptance criteria—accuracy, precision as well as the specificity and robustness—were defined and summarized. By passing the validation experiments described in this article the automated system for aliquoting has been successfully validated. This allows the standardized and operator independent distribution of small-scale and bulk amounts of HIV-1 pseudovirus stocks with a precise and reproducible outcome to support upcoming clinical vaccine trials. PMID:29300769
Design and development of automatic sharia compliant wheelchair wheels cleaner
NASA Astrophysics Data System (ADS)
Shaari, Muhammad Farid; Rasli, Ibrahim Ismail Mohammad; Jamaludin, M. Z. Z. Wan; Isa, W. A. Mohamad; M., H.; Rashid, A. H. Abdul
2017-04-01
Sharia compliant wheelchair wheel cleaner was developed in order to assist the muslim Person with Disabilities (PWD) to pray in the mosque without leaving their wheelchair because of the filthy wheels. Though there are many wheelchair wheel cleaning system in the market, it is very rare to find sharia compliant cleaning system that applies sertu concept which is one of the cleaning and purification technique in Islamic practice. The sertu concept is based on 6:1 ratio that refers to the six times pipe water cleaning and one time soiled water cleaning. The development process consists of design stage, fabrication and system installation stage and followed by testing stage. During the design stage, the proposed prototype underwent design brainstorming, operation programming and structural simulation analysis. Once fabricated, the cleaner prototype underwent was tested. The results showed that the prototype can cater load up to 100kg with 1.31×10-6 mm shaft bending displacement. The water ejection timing varied approximately 3% compared to the program.
Preliminary Assessment of a Compliant Gait Exoskeleton.
Cestari, Manuel; Sanz-Merodio, Daniel; Garcia, Elena
2017-06-01
Current commercial wearable gait exoskeletons contain joints with stiff actuators that cannot adapt to unpredictable environments. These actuators consume a significant amount of energy, and their stiffness may not be appropriate for safe human-machine interactions. Adjustable compliant actuators are being designed and implemented because of their ability to minimize large forces due to shocks, to safely interact with the user, and to store and release energy in passive elastic elements. Introduction of such compliant actuation in gait exoskeletons, however, has been limited by the larger power-to-weight and volume ratio requirement. This article presents a preliminary assessment of the first compliant exoskeleton for children. Compliant actuation systems developed by our research group were integrated into the ATLAS exoskeleton prototype. The resulting device is a compliant exoskeleton, the ATLAS-C prototype. The exoskeleton is coupled with a special standing frame to provide balance while allowing a semi-natural gait. Experiments show that when comparing the behavior of the joints under different stiffness conditions, the inherent compliance of the implemented actuators showed natural adaptability during the gait cycle and in regions of shock absorption. Torque tracking of the joint is achieved, identifying the areas of loading response. The implementation of a state machine in the control of knee motion allowed reutilization of the stored energy during deflection at the end of the support phase to partially propel the leg and achieve a more natural and free swing.
Embedded diagnostic, prognostic, and health management system and method for a humanoid robot
NASA Technical Reports Server (NTRS)
Barajas, Leandro G. (Inventor); Strawser, Philip A (Inventor); Sanders, Adam M (Inventor); Reiland, Matthew J (Inventor)
2013-01-01
A robotic system includes a humanoid robot with multiple compliant joints, each moveable using one or more of the actuators, and having sensors for measuring control and feedback data. A distributed controller controls the joints and other integrated system components over multiple high-speed communication networks. Diagnostic, prognostic, and health management (DPHM) modules are embedded within the robot at the various control levels. Each DPHM module measures, controls, and records DPHM data for the respective control level/connected device in a location that is accessible over the networks or via an external device. A method of controlling the robot includes embedding a plurality of the DPHM modules within multiple control levels of the distributed controller, using the DPHM modules to measure DPHM data within each of the control levels, and recording the DPHM data in a location that is accessible over at least one of the high-speed communication networks.
Design, fabrication and control of soft robots.
Rus, Daniela; Tolley, Michael T
2015-05-28
Conventionally, engineers have employed rigid materials to fabricate precise, predictable robotic systems, which are easily modelled as rigid members connected at discrete joints. Natural systems, however, often match or exceed the performance of robotic systems with deformable bodies. Cephalopods, for example, achieve amazing feats of manipulation and locomotion without a skeleton; even vertebrates such as humans achieve dynamic gaits by storing elastic energy in their compliant bones and soft tissues. Inspired by nature, engineers have begun to explore the design and control of soft-bodied robots composed of compliant materials. This Review discusses recent developments in the emerging field of soft robotics.
Reconfigurable, Intelligently-Adaptive, Communication System, an SDR Platform
NASA Technical Reports Server (NTRS)
Roche, Rigoberto J.; Shalkhauser, Mary Jo; Hickey, Joseph P.; Briones, Janette C.
2016-01-01
The Space Telecommunications Radio System (STRS) provides a common, consistent framework to abstract the application software from the radio platform hardware. STRS aims to reduce the cost and risk of using complex, configurable and reprogrammable radio systems across NASA missions. The NASA Glenn Research Center (GRC) team made a software defined radio (SDR) platform STRS compliant by adding an STRS operating environment and a field programmable gate array (FPGA) wrapper, capable of implementing each of the platforms interfaces, as well as a test waveform to exercise those interfaces. This effort serves to provide a framework toward waveform development onto an STRS compliant platform to support future space communication systems for advanced exploration missions. The use of validated STRS compliant applications provides tested code with extensive documentation to potentially reduce risk, cost and e ort in development of space-deployable SDRs. This paper discusses the advantages of STRS, the integration of STRS onto a Reconfigurable, Intelligently-Adaptive, Communication System (RIACS) SDR platform, and the test waveform and wrapper development e orts. The paper emphasizes the infusion of the STRS Architecture onto the RIACS platform for potential use in next generation flight system SDRs for advanced exploration missions.
Contribution of variable-speed pump hydro storage for power system dynamic performance
NASA Astrophysics Data System (ADS)
Silva, B.; Moreira, C.
2017-04-01
This paper presents the study of variable-speed Pump Storage Powerplant (PSP) in the Portuguese power system. It evaluates the progressive integration in three major locations and compares the power system performance following a severe fault event with consequent disconnection of non-Fault Ride-through (FRT) compliant Wind Farms (WF). To achieve such objective, a frequency responsive model was developed in PSS/E and was further used to substitute existing fixed-speed PSP. The results allow identifying a clear enhancement on the power system performance by the presence of frequency responsive variable-speed PSP, especially for the scenario presented, with high level of renewables integration.
Electrophysiological assessment in patients with long term hypoxia.
Ilik, Faik; Pazarli, Ahmet C; Kayhan, Fatih; Karamanli, Harun; Ozlece, Hatice K
2016-01-01
To evaluate visual evoked potentials (VEP) patterns in chronic obstructive pulmonary disease (COPD) patients who were compliant with supplemental oxygen treatment relative to non-compliant COPD patients. This prospective study protocol was reviewed and approved by the local ethical committee of Selcuk University and the research was performed in the Department of Neurology, Elbistan State Hospital, Kahramanmaras, Turkey from May to October 2014. Blood gas measurements and pulmonary function tests were carried out in patients with advanced stage COPD. The VEP was assessed in both eyes in both compliant and non-compliant patients. The study included 43 patients; 24 (55.8%) of the patients were not in compliance with their supplemental oxygen treatment, while 19 patients (44.2%) received adequate oxygen treatment. There was no statistically significant difference between patients with regards to pulmonary function test results and blood gas measurements. The VEP latency was significantly greater in both eyes of the non-compliant patients. Previous studies have reported prolonged VEP latencies in inflammatory diseases of the central nervous system. Similar electrophysiological findings were observed in our study and we propose that this may be due to oxidative stress, and inflammation that occurs secondary to chronic ischemia.
NASA Astrophysics Data System (ADS)
Canfield, Shawn; Edinger, Ben; Frecker, Mary I.; Koopmann, Gary H.
1999-06-01
Recent advances in robotics, tele-robotics, smart material actuators, and mechatronics raise new possibilities for innovative developments in millimeter-scale robotics capable of manipulating objects only fractions of a millimeter in size. These advances can have a wide range of applications in the biomedical community. A potential application of this technology is in minimally invasive surgery (MIS). The focus of this paper is the development of a single degree of freedom prototype to demonstrate the viability of smart materials, force feedback and compliant mechanisms for minimally invasive surgery. The prototype is a compliant gripper that is 7-mm by 17-mm, made from a single piece of titanium that is designed to function as a needle driver for small scale suturing. A custom designed piezoelectric `inchworm' actuator drives the gripper. The integrated system is computer controlled providing a user interface device capable of force feedback. The design methodology described draws from recent advances in three emerging fields in engineering: design of innovative tools for MIS, design of compliant mechanisms, and design of smart materials and actuators. The focus of this paper is on the design of a millimeter-scale inchworm actuator for use with a compliant end effector in MIS.
NASA Astrophysics Data System (ADS)
Leskiw, Donald M.; Zhau, Junmei
2000-06-01
This paper reports on results from an ongoing project to develop methodologies for representing and managing multiple, concurrent levels of detail and enabling high performance computing using parallel arrays within distributed object-based simulation frameworks. At this time we present the methodology for representing and managing multiple, concurrent levels of detail and modeling accuracy by using a representation based on the Kalman approach for estimation. The Kalman System Model equations are used to represent model accuracy, Kalman Measurement Model equations provide transformations between heterogeneous levels of detail, and interoperability among disparate abstractions is provided using a form of the Kalman Update equations.
Family of Advanced Beyond Line-of-Sight Terminals (FAB-T)
2015-12-01
Architecture (DoD IEA), excepting tactical and non- operational (OP) communications 3) Compliant with GIG Technical Guidance ( GTG ) to include...Information Technology (IT) standards identified in the Standards FAB-T December 2015 SAR March 21, 2016 15:24:15 UNCLASSIFIED 24 Technical Guidance ( GTG ...Availability Anti-spoofing Module (SAASM), Spectrum and Joint Tactical Radio System (JTRS) requirements. Compliant GTG to include IT standards
Ankle rehabilitation device with two degrees of freedom and compliant joint
NASA Astrophysics Data System (ADS)
Racu (Cazacu, C.-M.; Doroftei, I.
2015-11-01
We propose a rehabilitation device that we intend to be low cost and easy to manufacture. The system will ensure functionality but also have a small dimensions and low mass, considering the physiological dimensions of the foot and lower leg. To avoid injure of the ankle joint, this device is equipped with a compliant joint between the motor and mechanical transmission. The torque of this joint is intended to be adjustable, according to the degree of ankle joint damage. To choose the material and the dimensions of this compliant joint, in this paper we perform the first stress simulation. The minimum torque is calculated, while the maximum torque is given by the preliminary chosen actuator.
Integrating Genomic Resources with Electronic Health Records using the HL7 Infobutton Standard
Overby, Casey Lynnette; Del Fiol, Guilherme; Rubinstein, Wendy S.; Maglott, Donna R.; Nelson, Tristan H.; Milosavljevic, Aleksandar; Martin, Christa L.; Goehringer, Scott R.; Freimuth, Robert R.; Williams, Marc S.
2016-01-01
Summary Background The Clinical Genome Resource (ClinGen) Electronic Health Record (EHR) Workgroup aims to integrate ClinGen resources with EHRs. A promising option to enable this integration is through the Health Level Seven (HL7) Infobutton Standard. EHR systems that are certified according to the US Meaningful Use program provide HL7-compliant infobutton capabilities, which can be leveraged to support clinical decision-making in genomics. Objectives To integrate genomic knowledge resources using the HL7 infobutton standard. Two tactics to achieve this objective were: (1) creating an HL7-compliant search interface for ClinGen, and (2) proposing guidance for genomic resources on achieving HL7 Infobutton standard accessibility and compliance. Methods We built a search interface utilizing OpenInfobutton, an open source reference implementation of the HL7 Infobutton standard. ClinGen resources were assessed for readiness towards HL7 compliance. Finally, based upon our experiences we provide recommendations for publishers seeking to achieve HL7 compliance. Results Eight genomic resources and two sub-resources were integrated with the ClinGen search engine via OpenInfobutton and the HL7 infobutton standard. Resources we assessed have varying levels of readiness towards HL7-compliance. Furthermore, we found that adoption of standard terminologies used by EHR systems is the main gap to achieve compliance. Conclusion Genomic resources can be integrated with EHR systems via the HL7 Infobutton standard using OpenInfobutton. Full compliance of genomic resources with the Infobutton standard would further enhance interoperability with EHR systems. PMID:27579472
Compliant cantilevered micromold
Morales, Alfredo Martin [Pleasanton, CA; Domeier, Linda A [Danville, CA; Gonzales, Marcela G [Seattle, WA; Keifer, Patrick N [Livermore, CA; Garino, Terry Joseph [Albuquerque, NM
2006-08-15
A compliant cantilevered three-dimensional micromold is provided. The compliant cantilevered micromold is suitable for use in the replication of cantilevered microparts and greatly simplifies the replication of such cantilevered parts. The compliant cantilevered micromold may be used to fabricate microparts using casting or electroforming techniques. When the compliant micromold is used to fabricate electroformed cantilevered parts, the micromold will also comprise an electrically conducting base formed by a porous metal substrate that is embedded within the compliant cantilevered micromold. Methods for fabricating the compliant cantilevered micromold as well as methods of replicating cantilevered microparts using the compliant cantilevered micromold are also provided.
Method for providing a compliant cantilevered micromold
Morales, Alfredo M.; Domeier, Linda A.; Gonzales, Marcela G.; Keifer, Patrick N.; Garino, Terry J.
2008-12-16
A compliant cantilevered three-dimensional micromold is provided. The compliant cantilevered micromold is suitable for use in the replication of cantilevered microparts and greatly simplifies the replication of such cantilevered parts. The compliant cantilevered micromold may be used to fabricate microparts using casting or electroforming techniques. When the compliant micromold is used to fabricate electroformed cantilevered parts, the micromold will also comprise an electrically conducting base formed by a porous metal substrate that is embedded within the compliant cantilevered micromold. Methods for fabricating the compliant cantilevered micromold as well as methods of replicating cantilevered microparts using the compliant cantilevered micromold are also provided.
[Burnout, patient compliance and psychological withdrawal among GPs: an exploratory study].
Truchot, D; Roncari, N; Bantégnie, D
2011-02-01
When GPs are afflicted by burnout, patients' demands are perceived to create a relational imbalance. It can be supposed that in this situation, GPs will react by distancing themselves from the patient. Effectively, various studies suggest that health professionals who are suffering from burnout adapt withdrawal strategies towards their patients: less implication, etc. In the present study, we make the assumption that when the GP is suffering from burnout, the withdrawal will be even more important with a noncompliant patient. Two hundred and seventy GPs responded to the case of an 84 year-old female patient who lives alone and falls regularly. After having broken the neck of the thigh bone, she leaves the hospital and remains dependent for the next months. The patient is presented in two ways: compliant vs. non compliant. The GPs were asked to indicate the degree to which they would choose each of the solutions that were proposed. These solutions vary according to their degree of implication. Information on the participants' level of burnout was also gathered. When the patient is compliant, the implicating solutions (home assistance and home care) are chosen equally as much by the participants, whatever their level of emotional exhaustion. But when the patient is noncompliant, these solutions are always chosen as much by the participants with a low level of emotional exhaustion, but are significantly less chosen by those with a high level of emotional exhaustion. The opposite is found for withdrawal solutions (independent living residence, medium term hospital stay, retirement home). When the patient is compliant, the choice of these solutions does not vary in function of the level of exhaustion. However, when the patient is noncompliant, these solutions attract the GPs significantly more if they are exhausted (but not if they are slightly exhausted). Copyright © 2010. Published by Elsevier Masson SAS.
Wang, Z.; Ward, M. M.; Chan, L.
2014-01-01
Summary Previous studies have shown an association between duration of bisphosphonate use and atypical femur fractures. This cohort study showed an increasingly higher risk of subtrochanteric and femoral shaft fractures among those who were more adherent to oral bisphosphonates. Introduction Long-term use of oral bisphosphonates has been implicated in an increased risk of atypical femur fractures located in subtrochanteric and femoral shaft regions. Another measure of drug exposure, medication adherence, however, has not been investigated. Methods Among all Medicare fee-for-service female beneficiaries from 2006–2010, we followed 522,287 new bisphosphonate users from their index prescription until being censored or having a primary diagnosis of closed subtrochanteric/ femoral shaft or intertrochanteric/femoral neck fractures. Data about radiographs of fracture site and features were not available. Adherence was classified according to the medication possession ratio (MPR) as the following: MPR<1/3 as less compliant, MPR≥1/3–<2/3 as compliant, and MPR≥2/3 as highly compliant. Alternative cutoff points at 50 and 80 % were also used. Survival analysis was used to determine the cumulative incidence and hazard of subtrochanteric/femoral shaft or intertrochanteric/femoral neck fractures. Results There was a graded increase in incidence of subtrochanteric/femoral shaft fractures as the level of adherence increased (Gray’s test, P<0.001). The adjusted hazard ratio (HR) for the highly compliant vs. the less compliant was 1.23 (95 % Confidence Interval [CI] 1.06–1.43) overall, became significant after 2 years of follow-up (HR=1.51, 95 % CI 1.06–2.15) and reached the highest risk in the fifth year (HR=4.06, 95 % CI 1.47–11.19). However, age-adjusted incidence rates of intertrochanteric/femoral neck fractures were significantly lower among highly compliant beneficiaries, compared to less compliant users (HR=0.69, 95 % CI 0.66–0.73). Similar results were obtained when the cutoff points for being compliant and highly compliant were set at 50 and 80 %, respectively. Conclusions Subtrochanteric/femoral shaft fractures, unlike intertrochanteric/femoral neck fractures, are positively associated with higher adherence to long-term (≥3 years) oral bisphosphonates in the elderly female Medicare population. PMID:24846316
NASA Astrophysics Data System (ADS)
Whitefield, P. D.; Hagen, D. E.; Lobo, P.; Miake-Lye, R. C.
2015-12-01
The Society of Automotive Engineers (SAE) Aircraft Exhaust Emissions Measurement Committee (E-31) has published an Aerospace Information Report (AIR) 6241 detailing the sampling system for the measurement of non-volatile particulate matter (nvPM) from aircraft engines (SAE 2013). The system is designed to operate in parallel with existing International Civil Aviation Organization (ICAO) Annex 16 compliant combustion gas sampling systems used for emissions certification from aircraft engines captured by conventional (Annex 16) gas sampling rakes (ICAO, 2008). The SAE E-31 committee is also working to ballot an Aerospace Recommended Practice (ARP) that will provide the methodology and system specification to measure nvPM from aircraft engines. The ARP is currently in preparation and is expected to be ready for ballot in 2015. A prototype AIR-compliant nvPM measurement system - The North American Reference System (NARS) has been built and evaluated at the MSTCOE under the joint sponsorship of the FAA, EPA and Transport Canada. It has been used to validate the performance characteristics of OEM AIR-compliant systems and is being used in engine certification type testing at OEM facilities to obtain data from a set of representative engines in the fleet. The data collected during these tests will be used by ICAO/CAEP/WG3/PMTG to develop a metric on which on the regulation for nvPM emissions will be based. This paper will review the salient features of the NARS including: (1) emissions sample transport from probe tip to the key diagnostic tools, (2) the mass and number-based diagnostic tools for nvPM mass and number concentration measurement and (3) methods employed to assess the extent of nvPM loss throughout the sampling system. This paper will conclude with a discussion of the recent results from inter-comparison studies conducted with other US - based systems that gives credence to the ARP's readiness for ballot.
Compliant Metal Enhanced Convection Cooled Reverse-Flow Annular Combustor
NASA Technical Reports Server (NTRS)
Paskin, Marc D.; Acosta, Waldo A.
1994-01-01
A joint Army/NASA program was conducted to design, fabricate, and test an advanced, reverse-flow, small gas turbine combustor using a compliant metal enhanced (CME) convection wall cooling concept. The objectives of this effort were to develop a design method (basic design data base and analysis) for the CME cooling technique and tben demonstrate its application to an advanced cycle, small, reverse-flow combustor with 3000 F (1922 K) burner outlet temperature (BOT). The CME concept offers significant improvements in wall cooling effectiveness resulting in a large reduction in cooling air requirements. Therefore, more air is available for control of burner outlet temperature pattern in addition to the benefit of improved efficiency, reduced emissions, and smoke levels. Rig test results demonstrated the benefits and viability of the CME concept meeting or exceeding the aerothermal performance and liner wall temperature characteristics of similar lower temperature-rise combustors, achieving 0.15 pattern factor at 3000 F (1922 K) BOT, while utilizing approximately 80 percent less cooling air than conventional, film-cooled combustion systems.
Crump, Jacob K.; Del Fiol, Guilherme; Williams, Marc S.; Freimuth, Robert R.
2018-01-01
Integration of genetic information is becoming increasingly important in clinical practice. However, genetic information is often ambiguous and difficult to understand, and clinicians have reported low-self-efficacy in integrating genetics into their care routine. The Health Level Seven (HL7) Infobutton standard helps to integrate online knowledge resources within Electronic Health Records (EHRs) and is required for EHR certification in the US. We implemented a prototype of a standards-based genetic reporting application coupled with infobuttons leveraging the Infobutton and Fast Healthcare Interoperability Resources (FHIR) Standards. Infobutton capabilities were provided by Open Infobutton, an open source package compliant with the HL7 Infobutton Standard. The resulting prototype demonstrates how standards-based reporting of genetic results, coupled with curated knowledge resources, can provide dynamic access to clinical knowledge on demand at the point of care. The proposed functionality can be enabled within any EHR system that has been certified through the US Meaningful Use program.
Compliant leg behaviour explains basic dynamics of walking and running
Geyer, Hartmut; Seyfarth, Andre; Blickhan, Reinhard
2006-01-01
The basic mechanics of human locomotion are associated with vaulting over stiff legs in walking and rebounding on compliant legs in running. However, while rebounding legs well explain the stance dynamics of running, stiff legs cannot reproduce that of walking. With a simple bipedal spring–mass model, we show that not stiff but compliant legs are essential to obtain the basic walking mechanics; incorporating the double support as an essential part of the walking motion, the model reproduces the characteristic stance dynamics that result in the observed small vertical oscillation of the body and the observed out-of-phase changes in forward kinetic and gravitational potential energies. Exploring the parameter space of this model, we further show that it not only combines the basic dynamics of walking and running in one mechanical system, but also reveals these gaits to be just two out of the many solutions to legged locomotion offered by compliant leg behaviour and accessed by energy or speed. PMID:17015312
Barckhausen, Christina; Rice, Brent; Baila, Stefano; Sensebé, Luc; Schrezenmeier, Hubert; Nold, Philipp; Hackstein, Holger; Rojewski, Markus Thomas
2016-01-01
This chapter describes a method for GMP-compliant expansion of human mesenchymal stromal/stem cells (hMSC) from bone marrow aspirates, using the Quantum(®) Cell Expansion System from Terumo BCT. The Quantum system is a functionally closed, automated hollow fiber bioreactor system designed to reproducibly grow cells in either GMP or research laboratory environments. The chapter includes protocols for preparation of media, setup of the Quantum system, coating of the hollow fiber bioreactor, as well as loading, feeding, and harvesting of cells. We suggest a panel of quality controls for the starting material, the interim product, as well as the final product.
Reward-Modulated Hebbian Plasticity as Leverage for Partially Embodied Control in Compliant Robotics
Burms, Jeroen; Caluwaerts, Ken; Dambre, Joni
2015-01-01
In embodied computation (or morphological computation), part of the complexity of motor control is offloaded to the body dynamics. We demonstrate that a simple Hebbian-like learning rule can be used to train systems with (partial) embodiment, and can be extended outside of the scope of traditional neural networks. To this end, we apply the learning rule to optimize the connection weights of recurrent neural networks with different topologies and for various tasks. We then apply this learning rule to a simulated compliant tensegrity robot by optimizing static feedback controllers that directly exploit the dynamics of the robot body. This leads to partially embodied controllers, i.e., hybrid controllers that naturally integrate the computations that are performed by the robot body into a neural network architecture. Our results demonstrate the universal applicability of reward-modulated Hebbian learning. Furthermore, they demonstrate the robustness of systems trained with the learning rule. This study strengthens our belief that compliant robots should or can be seen as computational units, instead of dumb hardware that needs a complex controller. This link between compliant robotics and neural networks is also the main reason for our search for simple universal learning rules for both neural networks and robotics. PMID:26347645
The Information System at CeSAM
NASA Astrophysics Data System (ADS)
Agneray, F.; Gimenez, S.; Moreau, C.; Roehlly, Y.
2012-09-01
Modern large observational programmes produce important amounts of data from various origins, and need high level quality control, fast data access via easy-to-use graphic interfaces, as well as possibility to cross-correlate informations coming from different observations. The Centre de donnéeS Astrophysique de Marseille (CeSAM) offer web access to VO compliant Information Systems to access data of different projects (VVDS, HeDAM, EXODAT, HST-COSMOS,…), including ancillary data obtained outside Laboratoire d'Astrophysique de Marseille (LAM) control. The CeSAM Information Systems provides download of catalogues and some additional services like: search, extract and display imaging and spectroscopic data by multi-criteria and Cone Search interfaces.
Umeh, Gregory C; Nomhwange, Terna Ignatius; Shamang, Anthony F; Zakari, Furera; Musa, Audu I; Dogo, Paul M; Gugong, Victor; Iliyasu, Neyu
2018-02-08
Attitude and subjective well-being are important factors in mothers accepting or rejecting Oral Polio Vaccine (OPV) supplemental immunization. The purpose of the study was to determine the role of mothers' attitude and subjective wellbeing on non-compliance to OPV supplemental immunization in Northern Nigeria. The study utilized a cross-sectional design to assess attitude and subjective well-being of mothers using previously validated VACSATC (Vaccine Safety, Attitudes, Training and Communication-10 items) & SUBI (Subjective Well-being Inventory-40 items) measures. A total of 396 participants (equal number of non-compliant and compliant mothers) from 94 non-compliant settlements were interviewed, after informed consent. T-test was run to assess difference in mean scores between the non-compliant and compliant mothers on VACSATC and SUBI measures. The research showed a significant difference in mean scores between the non-compliant and compliant groups on VACSATC measure of mothers' attitude (M = 18.9 non-compliant, compared to 26.5 compliant; p < 0.05). On subjective well-being, the study showed there was no significant difference in the mean scores of the SUBI measure (M = 77.4 non-compliant, compared to 78.0 compliant; p > 0.05). The research has shown that negative attitude is more commonly present in non-compliant mothers and may be a factor in vaccine refusal in Northern Nigeria.
An audit of dental prescriptions between clinics and dental laboratories.
Stewart, C A
2011-08-12
To discover the quality of written instructions from dentists to dental technicians and the nature of non-compliant prescriptions. An audit of laboratory prescription compliance was conducted within an NHS Trust Dental Teaching Hospital to determine the level of communication between dentists and dental technicians. One hundred and fifty prescriptions were audited from dental undergraduates and qualified dentists throughout the different departments. A total of two-thirds of prescriptions were considered non-compliant and failed to meet relevant ethical and legal guidelines. This problem was seen throughout all departments and at all professional levels. A breakdown in communication between dentists and technicians through the use of prescriptions is evident even within a close working environment.
Handedness in shearing auxetics creates rigid and compliant structures
NASA Astrophysics Data System (ADS)
Lipton, Jeffrey Ian; MacCurdy, Robert; Manchester, Zachary; Chin, Lillian; Cellucci, Daniel; Rus, Daniela
2018-05-01
In nature, repeated base units produce handed structures that selectively bond to make rigid or compliant materials. Auxetic tilings are scale-independent frameworks made from repeated unit cells that expand under tension. We discovered how to produce handedness in auxetic unit cells that shear as they expand by changing the symmetries and alignments of auxetic tilings. Using the symmetry and alignment rules that we developed, we made handed shearing auxetics that tile planes, cylinders, and spheres. By compositing the handed shearing auxetics in a manner inspired by keratin and collagen, we produce both compliant structures that expand while twisting and deployable structures that can rigidly lock. This work opens up new possibilities in designing chemical frameworks, medical devices like stents, robotic systems, and deployable engineering structures.
Simulation study of the ROMPS robot control system
NASA Technical Reports Server (NTRS)
Nguyen, Charles C.; Liu, HUI-I.
1994-01-01
This is a report presenting the progress of a research grant funded by NASA for work performed from June 1, 1993 to August 1, 1993. The report deals with the Robot Operated Material Processing System (ROMPS). It presents results of a computer simulation study conducted to investigate the performance of the control systems controlling the azimuth, elevation, and radial axes of the ROMPS and its gripper. Four study cases are conducted. The first case investigates the control of free motion of the three areas. In the second case, the compliant motion in the elevation axis with the wrist compliant device is studied in terms of position accuracy and impact forces. The third case focuses on the behavior of the control system in controlling the robot motion along the radial axis when pulling the pallet out of the rack. In the fourth case, the compliant motion of the gripper grasping a solid object under the effect of the gripper passive compliance is studied in terms of position accuracy and contact forces. For each of the above cases, a set of PIR gains will be selected to optimize the controller performance and computer simulation results will be presented and discussed.
Compliant Task Execution and Learning for Safe Mixed-Initiative Human-Robot Operations
NASA Technical Reports Server (NTRS)
Dong, Shuonan; Conrad, Patrick R.; Shah, Julie A.; Williams, Brian C.; Mittman, David S.; Ingham, Michel D.; Verma, Vandana
2011-01-01
We introduce a novel task execution capability that enhances the ability of in-situ crew members to function independently from Earth by enabling safe and efficient interaction with automated systems. This task execution capability provides the ability to (1) map goal-directed commands from humans into safe, compliant, automated actions, (2) quickly and safely respond to human commands and actions during task execution, and (3) specify complex motions through teaching by demonstration. Our results are applicable to future surface robotic systems, and we have demonstrated these capabilities on JPL's All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) robot.
Kalash, D; Vovk, A; Huang, H; Aukhil, I; Wallet, S M; Shaddox, L M
2015-01-01
A previous study has shown that children with localized aggressive periodontitis (LAP) demonstrate a lipopolysaccharide (LPS) hyper-responsiveness in addition to elevated levels of systemic LPS when compared to periodontally healthy children. The purpose of this study was to evaluate whether periodontal therapy modulates systemic lipopolysaccharide levels and whether these levels may influence clinical outcomes. Peripheral blood samples and clinical parameters (probing depth [PD], clinical attachment levels [CAL], percent sites greater than four mm, bleeding on probing [BoP], and visible plaque [P]) were collected from 29 LAP patients prior to and at three, six, and 12 months following scaling and root planning and systemic antibiotics. Serum LPS levels were quantified using a chromogenic assay. Twenty-five patients were compliant with the prescribed antibiotic treatment and demonstrated a significant reduction in LPS as well as overall PD, CAL, and plaque at all time points post-therapy. Additionally LPS reductions correlated with reductions in PD, CAL, and plaque. Localized aggressive periodontitis therapy with antibiotics plays an important role in reducing systemic lipopolysaccharide levels. Since LPS is a key mediator of the LAP hyperinflammatory response, its systemic reduction is especially important for the successful management of these children.
The influence of novel compliant floors on balance control in elderly women--A biomechanical study.
Wright, Alexander D; Laing, Andrew C
2011-07-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (SmartCell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard 'Rigid' floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
The influence of novel compliant floors on balance control in elderly women—A biomechanical study
Wright, Alexander D.; Laing, Andrew C.
2012-01-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (Smart-Cell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard ‘Rigid’ floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. PMID:21545881
NASA Technical Reports Server (NTRS)
Bellomy-Ezell, Jenny; Farmer, Jeff; Breeding, Shawn; Spivey, Reggie
2001-01-01
A compliant, thermal interface material is tested to evaluate its thermal behavior at elevated temperatures, in vacuum conditions, and under varying levels of compression. Preliminary results indicate that the thermal performance of this polymer fiber-based, felt-like material is sufficient to meet thermal extraction requirements for the Quench Module Insert, a Bridgman furnace for microgravity material science investigation. This paper discusses testing and modeling approaches employed, gives of a status of characterization activities and provides preliminary test results.
dos-Santos, M; Fujino, A
2012-01-01
Radiology teaching usually employs a systematic and comprehensive set of medical images and related information. Databases with representative radiological images and documents are highly desirable and widely used in Radiology teaching programs. Currently, computer-based teaching file systems are widely used in Medicine and Radiology teaching as an educational resource. This work addresses a user-centered radiology electronic teaching file system as an instance of MIRC compliant medical image database. Such as a digital library, the clinical cases are available to access by using a web browser. The system has offered great opportunities to some Radiology residents interact with experts. This has been done by applying user-centered techniques and creating usage context-based tools in order to make available an interactive system.
Vita, V; Clausi, M T; Franchino, C; De Pace, R
2016-11-01
During a 5-year period from 2010 to 2014, n = 919 samples of feed and raw materials were analyzed for aflatoxin B 1 (AFB 1 ) contamination using accredited ELISA screening methods. Only 0.76 % of these samples were non-compliant with maximum levels set by the European Union Regulation 32/2002. Non-compliant samples were mainly from the province of Bari (n = 3 samples, mean AFB 1 value 7.03 μg/kg), although the highest AFB 1 levels were found in two samples from the provinces of Foggia and Brindisi, at 32.6 ± 3.6 μg/kg and 31.0 ± 4.0 μg/kg, respectively. Mean AFB 1 levels in samples contaminated but compliant with the limits ranged from 1.4 to 2.2 μg/kg. Considering the great importance of climate conditions in mycotoxins production, during crops production and during the critical phases of materials storage and/or transport, to better understand the variability in contamination levels, the analytical results were reviewed in term of temperature and relative environmental humidity in the sampling areas. Correlations between aflatoxin B 1 levels in feed and these climate factors might explain seasonal and annual variations in contamination levels. The data from the present study provide useful suggestions for the organization of targeted monitoring plans and the protection of consumers, as well as for improvement in the quality standards of zootechnological activities and feed industry.
The demand for statin: the effect of copay on utilization and compliance.
Thiebaud, Patrick; Patel, Bimal V; Nichol, Michael B
2008-01-01
Increasing drug costs in the US have prompted employers and insurers alike to turn to higher drug copays for cost containment. The effect of rising copays on compliance with statins (HMG-CoA reductase inhibitors) treatment has received surprisingly little attention in the applied literature. This paper uses pharmacy claims data from a commercially insured adult population to determine the effect of copay change on compliance at the individual level. Fixed effect logit and Poisson regressions estimate the effect of copays on monthly likelihood of high compliance and average monthly days of supply respectively. Higher copays reduce compliance among statin users, with less compliant patients responding more strongly to copay change than compliant patients. These results suggest that specific financial incentives given to less compliant patients could improve compliance with statin treatment at a relatively low cost. Copyright (c) 2007 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Lee, Jasper C.; Ma, Kevin C.; Liu, Brent J.
2008-03-01
A Data Grid for medical images has been developed at the Image Processing and Informatics Laboratory, USC to provide distribution and fault-tolerant storage of medical imaging studies across Internet2 and public domain. Although back-up policies and grid certificates guarantee privacy and authenticity of grid-access-points, there still lacks a method to guarantee the sensitive DICOM images have not been altered or corrupted during transmission across a public domain. This paper takes steps toward achieving full image transfer security within the Data Grid by utilizing DICOM image authentication and a HIPAA-compliant auditing system. The 3-D lossless digital signature embedding procedure involves a private 64 byte signature that is embedded into each original DICOM image volume, whereby on the receiving end the signature can to be extracted and verified following the DICOM transmission. This digital signature method has also been developed at the IPILab. The HIPAA-Compliant Auditing System (H-CAS) is required to monitor embedding and verification events, and allows monitoring of other grid activity as well. The H-CAS system federates the logs of transmission and authentication events at each grid-access-point and stores it into a HIPAA-compliant database. The auditing toolkit is installed at the local grid-access-point and utilizes Syslog [1], a client-server standard for log messaging over an IP network, to send messages to the H-CAS centralized database. By integrating digital image signatures and centralized logging capabilities, DICOM image integrity within the Medical Imaging and Informatics Data Grid can be monitored and guaranteed without loss to any image quality.
New integrated silicon-PDMS process for compliant micro-mechanisms
NASA Astrophysics Data System (ADS)
Haouas, Wissem; Dahmouche, Redwan; Agnus, Joël; Le Fort-Piat, Nadine; Laurent, Guillaume J.
2017-12-01
Polydimethylsiloxane (PDMS) elastomers are used for many applications, such as microfluidics and micro-engineering. This paper presents a new process of integrating soft elastomers into a silicon structure without any assembly steps. The novelty of this process is the use of only one deep reactive ion etch (DRIE) instead of two or more as developed in previous works. Thus, this fabrication process allows the use of elastomers that are usually not compatible with some fabrication processes. Compliant flexures with different interference shapes have been designed, simulated, fabricated, and characterized for generic use and notably for micro-robot joints and compliant micro-systems. The experimental results show that the 400 μm × 400 μm cross-sectional area samples can be bended more than 60\\circ without delamination.
Advanced public transportation systems benefits
DOT National Transportation Integrated Search
1996-03-01
Benefits and cost savings for various Advanced Public Transportation Systems are outlined here. Operational efficiencies are given for Transit Management Systems in different locales, as well as compliant resolution and safety. Electronic Fare Paymen...
W-026, transuranic waste restricted waste management (TRU RWM) glovebox operational test report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leist, K.J.
1998-02-18
The TRU Waste/Restricted Waste Management (LLW/PWNP) Glovebox 401 is designed to accept and process waste from the Transuranic Process Glovebox 302. Waste is transferred to the glovebox via the Drath and Schraeder Bagless Transfer Port (DO-07401) on a transfer stand. The stand is removed with a hoist and the operator inspects the waste (with the aid of the Sampling and Treatment Director) to determine a course of action for each item. The waste is separated into compliant and non compliant. One Trip Port DO-07402A is designated as ``Compliant``and One Trip Port DO-07402B is designated as ``Non Compliant``. As the processingmore » (inspection, bar coding, sampling and treatment) of the transferred items takes place, residue is placed in the appropriate One Trip port. The status of the waste items is tracked by the Data Management System (DMS) via the Plant Control System (PCS) barcode interface. As an item is moved for sampling or storage or it`s state altered by treatment, the Operator will track an items location using a portable barcode reader and entry any required data on the DMS console. The Operational Test Procedure (OTP) will perform evolutions (described here) using the Plant Operating Procedures (POP) in order to verify that they are sufficient and accurate for controlled glovebox operation.« less
SeaDataNet Pan-European infrastructure for Ocean & Marine Data Management
NASA Astrophysics Data System (ADS)
Manzella, G. M.; Maillard, C.; Maudire, G.; Schaap, D.; Rickards, L.; Nast, F.; Balopoulos, E.; Mikhailov, N.; Vladymyrov, V.; Pissierssens, P.; Schlitzer, R.; Beckers, J. M.; Barale, V.
2007-12-01
SEADATANET is developing a Pan-European data management infrastructure to insure access to a large number of marine environmental data (i.e. temperature, salinity current, sea level, chemical, physical and biological properties), safeguard and long term archiving. Data are derived from many different sensors installed on board of research vessels, satellite and the various platforms of the marine observing system. SeaDataNet allows to have information on real time and archived marine environmental data collected at a pan-european level, through directories on marine environmental data and projects. SeaDataNet allows the access to the most comprehensive multidisciplinary sets of marine in-situ and remote sensing data, from about 40 laboratories, through user friendly tools. The data selection and access is operated through the Common Data Index (CDI), XML files compliant with ISO standards and unified dictionaries. Technical Developments carried out by SeaDataNet includes: A library of Standards - Meta-data standards, compliant with ISO 19115, for communication and interoperability between the data platforms. Software of interoperable on line system - Interconnection of distributed data centres by interfacing adapted communication technology tools. Off-Line Data Management software - software representing the minimum equipment of all the data centres is developed by AWI "Ocean Data View (ODV)". Training, Education and Capacity Building - Training 'on the job' is carried out by IOC-Unesco in Ostende. SeaDataNet Virtual Educational Centre internet portal provides basic tools for informal education
Multiple-degree-of-freedom vehicle
Borenstein, Johann
1995-01-01
A multi-degree-of-freedom vehicle employs a compliant linkage to accommodate the need for a variation in the distance between drive wheels or drive systems which are independently steerable and drivable. The subject vehicle is provided with rotary encodes to provide signals representative of the orientation of the steering pivot associated with each such drive wheel or system, and a linear encoder which issues a signal representative of the fluctuations in the distance between the drive elements. The wheels of the vehicle are steered and driven in response to the linear encoder signal, there being provided a controller system for minimizing the fluctuations in the distance. The controller system is a software implementation of a plurality of controllers, operating at the chassis level and at the vehicle level. A trajectory interpolator receives x-displacement, y-displacement, and .theta.-displacement signals and produces to the vehicle level controller trajectory signals corresponding to interpolated control signals. The x-displacement, y-displacement, and .theta.-displacement signals are received from a human operator, via a manipulable joy stick.
GODIVA2: interactive visualization of environmental data on the Web.
Blower, J D; Haines, K; Santokhee, A; Liu, C L
2009-03-13
GODIVA2 is a dynamic website that provides visual access to several terabytes of physically distributed, four-dimensional environmental data. It allows users to explore large datasets interactively without the need to install new software or download and understand complex data. Through the use of open international standards, GODIVA2 maintains a high level of interoperability with third-party systems, allowing diverse datasets to be mutually compared. Scientists can use the system to search for features in large datasets and to diagnose the output from numerical simulations and data processing algorithms. Data providers around Europe have adopted GODIVA2 as an INSPIRE-compliant dynamic quick-view system for providing visual access to their data.
Human-like Compliance for Dexterous Robot Hands
NASA Technical Reports Server (NTRS)
Jau, Bruno M.
1995-01-01
This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.
Eccher, Claudio; Eccher, Lorenzo; Izzo, Umberto
2005-01-01
In this poster we describe the security solutions implemented in a web-based cooperative work frame-work for managing heart failure patients among different health care professionals involved in the care process. The solution, developed in close collaboration with the Law Department of the University of Trento, is compliant with the new Italian Personal Data Protection Code, issued in 2003, that regulates also the storing and processing of health data.
Uncoupling File System Components for Bridging Legacy and Modern Storage Architectures
NASA Astrophysics Data System (ADS)
Golpayegani, N.; Halem, M.; Tilmes, C.; Prathapan, S.; Earp, D. N.; Ashkar, J. S.
2016-12-01
Long running Earth Science projects can span decades of architectural changes in both processing and storage environments. As storage architecture designs change over decades such projects need to adjust their tools, systems, and expertise to properly integrate such new technologies with their legacy systems. Traditional file systems lack the necessary support to accommodate such hybrid storage infrastructure resulting in more complex tool development to encompass all possible storage architectures used for the project. The MODIS Adaptive Processing System (MODAPS) and the Level 1 and Atmospheres Archive and Distribution System (LAADS) is an example of a project spanning several decades which has evolved into a hybrid storage architecture. MODAPS/LAADS has developed the Lightweight Virtual File System (LVFS) which ensures a seamless integration of all the different storage architectures, including standard block based POSIX compliant storage disks, to object based architectures such as the S3 compliant HGST Active Archive System, and the Seagate Kinetic disks utilizing the Kinetic Protocol. With LVFS, all analysis and processing tools used for the project continue to function unmodified regardless of the underlying storage architecture enabling MODAPS/LAADS to easily integrate any new storage architecture without the costly need to modify existing tools to utilize such new systems. Most file systems are designed as a single application responsible for using metadata to organizing the data into a tree, determine the location for data storage, and a method of data retrieval. We will show how LVFS' unique approach of treating these components in a loosely coupled fashion enables it to merge different storage architectures into a single uniform storage system which bridges the underlying hybrid architecture.
Analytical modeling and experimental evaluation of a passively morphing ornithopter wing
NASA Astrophysics Data System (ADS)
Wissa, Aimy A.
Ornithopters or flapping wing Unmanned Aerial Vehicles (UAVs) have potential applications in both civil and military sectors. Amongst all categories of UAVs, ornithopters have a unique ability to fly in low Reynolds number flight regimes and have the agility and maneuverability of rotary wing aircraft. In nature, birds achieve such performance by exploiting various wing kinematics known as gaits. The objective of this work was to improve the steady level flight wing performance of an ornithopter by implementing the Continuous Vortex Gait (CVG) using a novel passive compliant spine. The CVG is a set of bio-inspired kinematics that natural flyers use to produce lift and thrust during steady level flight. A significant contribution of this work was the recognition that the CVG is an avian gait that could be achieved using a passive morphing mechanism. In contrast to rigid-link mechanisms and active approaches, reported by other researchers in the open literature, passive morphing mechanisms require no additional energy expenditure, while introducing minimal weight addition and complexity. During the execution of the CVG, the avian wing wrist is the primary joint responsible for the wing shape changes. Thus a compliant mechanism, called a compliant spine, was fabricated, and integrated in the ornithopter's wing leading edge spar where an avian wrist would normally exist, namely at 37% of the wing half span. Each compliant spine was designed to be flexible in bending during the wing upstroke and stiff in bending during the wing downstroke. Inserting a variable stiffness compliant mechanism in the leading edge (LE) spar of the ornithopter could affect its structural stability. An analytical model was developed to determine the structural stability of the ornithopter LE spar. The model was validated using experimental measurements. The LE spar equations of motion were then reformulated into Mathieu's equation and the LE spar was proven to be structurally stable with a compliant spine design insert. A research ornithopter platform was tested in air and in vacuum as well as in free and constrained flight with various compliant spine designs inserted in its wings. Results from the constrained flight tests indicated that the ornithopter with a compliant spine inserted in its wings consumed 45% less electrical power and produced 16% of its weight in additional lift, without incurring any thrust penalties. Results from, the vacuum constrained tests attributed these benefits to aerodynamic effects rather than inertial effects. Free flight tests were performed at Wright Patterson Air Force Base, which houses the largest indoor flight laboratory in the country. The wing kinematics along with the vehicle dynamics were captured during this testing using ViconRTM motion tracking cameras. These flight tests proved to be successful in producing consistent and repeatable flight data over more than eight free flight flapping cycles of free flight and validated a new and novel testing technique. The ornithopter body dynamics were shown to be significant, i.e. +/-4gs. Inserting the compliant spine into the leading edge spar of the ornithopter during free flight reduced the baseline configuration body vertical center of mass positive acceleration by 69%, which translates into overall lift gains. It also increased the horizontal propulsive force by 300%, which translates into thrust gains.
Mulvihill, Christine M; Salmon, Paul M; Beanland, Vanessa; Lenné, Michael G; Read, Gemma J M; Walker, Guy H; Stanton, Neville A
2016-09-01
Rail level crossings (RLXs) represent a key strategic risk for railways worldwide. Despite enforcement and engineering countermeasures, user behaviour at RLXs can often confound expectations and erode safety. Research in this area is limited by a relative absence of insights into actual decision making processes and a focus on only a subset of road user types. One-hundred and sixty-six road users (drivers, motorcyclists, cyclists and pedestrians) completed a diary entry for each of 457 naturalistic encounters with RLXs when a train was approaching. The final eligible sample comprised 94 participants and 248 encounters at actively controlled crossings where a violation of the active warnings was possible. The diary incorporated Critical Decision Method probe questions, which enabled user responses to be mapped onto Rasmussen's decision ladder. Twelve percent of crossing events were non-compliant. The underlying decision making was compared to compliant events and a reference decision model to reveal important differences in the structure and type of decision making within and between road user groups. The findings show that engineering countermeasures intended to improve decision making (e.g. flashing lights), may have the opposite effect for some users because the system permits a high level of flexibility for circumvention. Non-motorised users were more likely to access information outside of the warning signals because of their ability to achieve greater proximity to the train tracks and the train itself. The major conundrum in resolving these issues is whether to restrict the amount of time and information available to users so that it cannot be used for circumventing the system or provide more information to help users make safe decisions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Making Interoperability Easier with the NASA Metadata Management Tool
NASA Astrophysics Data System (ADS)
Shum, D.; Reese, M.; Pilone, D.; Mitchell, A. E.
2016-12-01
ISO 19115 has enabled interoperability amongst tools, yet many users find it hard to build ISO metadata for their collections because it can be large and overly flexible for their needs. The Metadata Management Tool (MMT), part of NASA's Earth Observing System Data and Information System (EOSDIS), offers users a modern, easy to use browser based tool to develop ISO compliant metadata. Through a simplified UI experience, metadata curators can create and edit collections without any understanding of the complex ISO-19115 format, while still generating compliant metadata. The MMT is also able to assess the completeness of collection level metadata by evaluating it against a variety of metadata standards. The tool provides users with clear guidance as to how to change their metadata in order to improve their quality and compliance. It is based on NASA's Unified Metadata Model for Collections (UMM-C) which is a simpler metadata model which can be cleanly mapped to ISO 19115. This allows metadata authors and curators to meet ISO compliance requirements faster and more accurately. The MMT and UMM-C have been developed in an agile fashion, with recurring end user tests and reviews to continually refine the tool, the model and the ISO mappings. This process is allowing for continual improvement and evolution to meet the community's needs.
Seebregts, Christopher; Dane, Pierre; Parsons, Annie Neo; Fogwill, Thomas; Rogers, Debbie; Bekker, Marcha; Shaw, Vincent; Barron, Peter
2018-01-01
MomConnect is a national initiative coordinated by the South African National Department of Health that sends text-based mobile phone messages free of charge to pregnant women who voluntarily register at any public healthcare facility in South Africa. We describe the system design and architecture of the MomConnect technical platform, planned as a nationally scalable and extensible initiative. It uses a health information exchange that can connect any standards-compliant electronic front-end application to any standards-compliant electronic back-end database. The implementation of the MomConnect technical platform, in turn, is a national reference application for electronic interoperability in line with the South African National Health Normative Standards Framework. The use of open content and messaging standards enables the architecture to include any application adhering to the selected standards. Its national implementation at scale demonstrates both the use of this technology and a key objective of global health information systems, which is to achieve implementation scale. The system's limited clinical information, initially, allowed the architecture to focus on the base standards and profiles for interoperability in a resource-constrained environment with limited connectivity and infrastructural capacity. Maintenance of the system requires mobilisation of national resources. Future work aims to use the standard interfaces to include data from additional applications as well as to extend and interface the framework with other public health information systems in South Africa. The development of this platform has also shown the benefits of interoperability at both an organisational and technical level in South Africa.
Facial recognition trial: biometric identification of non-compliant subjects using CCTV
NASA Astrophysics Data System (ADS)
Best, Tim
2007-10-01
LogicaCMG were provided with an opportunity to deploy a facial recognition system in a realistic scenario. 12 cameras were installed at an international airport covering all entrances to the immigration hall. The evaluation took place over several months with numerous adjustments to both the hardware (i.e. cameras, servers and capture cards) and software. The learning curve has been very steep but a stage has now been reached where both LogicaCMG and the client are confident that, subject to the right environmental conditions (lighting and camera location) an effective system can be defined with a high probability of successful detection of the target individual, with minimal false alarms. To the best of our knowledge, results with a >90% detection rate, of non-compliant subjects 'at range' has not been achieved anywhere else. This puts this location at the forefront of capability in this area. The results achieved demonstrate that, given optimised conditions, it is possible to achieve a long range biometric identification of a non compliant subject, with a high rate of success.
Flight Testing of Novel Compliant Spines for Passive Wing Morphing on Ornithopters
NASA Technical Reports Server (NTRS)
Wissa, Aimy; Guerreiro, Nelson; Grauer, Jared; Altenbuchner, Cornelia; Hubbard, James E., Jr.; Tummala, Yashwanth; Frecker, Mary; Roberts, Richard
2013-01-01
Unmanned Aerial Vehicles (UAVs) are proliferating in both the civil and military markets. Flapping wing UAVs, or ornithopters, have the potential to combine the agility and maneuverability of rotary wing aircraft with excellent performance in low Reynolds number flight regimes. The purpose of this paper is to present new free flight experimental results for an ornithopter equipped with one degree of freedom (1DOF) compliant spines that were designed and optimized in terms of mass, maximum von-Mises stress, and desired wing bending deflections. The spines were inserted in an experimental ornithopter wing spar in order to achieve a set of desired kinematics during the up and down strokes of a flapping cycle. The ornithopter was flown at Wright Patterson Air Force Base in the Air Force Research Laboratory Small Unmanned Air Systems (SUAS) indoor flight facility. Vicon motion tracking cameras were used to track the motion of the vehicle for five different wing configurations. The effect of the presence of the compliant spine on wing kinematics and leading edge spar deflection during flight is presented. Results show that the ornithopter with the compliant spine inserted in its wing reduced the body acceleration during the upstroke which translates into overall lift gains.
Hallberg, Lance M; Ward, Jonathan B; Wickliffe, Jeffrey K; Ameredes, Bill T
2017-01-01
Since its beginning, more than 117 years ago, the compression-ignition engine, or diesel engine, has grown to become a critically important part of industry and transportation. Public concerns over the health effects from diesel emissions have driven the growth of regulatory development, implementation, and technological advances in emission controls. In 2001, the United States Environmental Protection Agency and California Air Resources Board issued new diesel fuel and emission standards for heavy-duty engines. To meet these stringent standards, manufacturers used new emission after-treatment technology, and modified fuel formulations, to bring about reductions in particulate matter and nitrogen oxides within the exhaust. To illustrate the impact of that technological transition, a brief overview of pre-2007 diesel engine exhaust biomarkers of genotoxicity and health-related concerns is provided, to set the context for the results of our research findings, as part of the Advanced Collaborative Emissions Study (ACES), in which the effects of a 2007-compliant diesel engine were examined. In agreement with ACES findings reported in other tissues, we observed a lack of measurable 2007-compliant diesel treatment–associated DNA damage, in lung tissue (comet assay), blood serum (8-hydroxy-2′-deoxyguanosine [8-OHdG] assay), and hippocampus (lipid peroxidation assay), across diesel exhaust exposure levels. A time-dependent assessment of 8-OHdG and lipid peroxidation also suggested no differences in responses across diesel exhaust exposure levels more than 24 months of exposure. These results indicated that the 2007-compliant diesel engine reduced measurable reactive oxygen species–associated tissue derangements and suggested that the 2007 standards–based mitigation approaches were effective. PMID:28659715
A Standard-Compliant Virtual Meeting System with Active Video Object Tracking
NASA Astrophysics Data System (ADS)
Lin, Chia-Wen; Chang, Yao-Jen; Wang, Chih-Ming; Chen, Yung-Chang; Sun, Ming-Ting
2002-12-01
This paper presents an H.323 standard compliant virtual video conferencing system. The proposed system not only serves as a multipoint control unit (MCU) for multipoint connection but also provides a gateway function between the H.323 LAN (local-area network) and the H.324 WAN (wide-area network) users. The proposed virtual video conferencing system provides user-friendly object compositing and manipulation features including 2D video object scaling, repositioning, rotation, and dynamic bit-allocation in a 3D virtual environment. A reliable, and accurate scheme based on background image mosaics is proposed for real-time extracting and tracking foreground video objects from the video captured with an active camera. Chroma-key insertion is used to facilitate video objects extraction and manipulation. We have implemented a prototype of the virtual conference system with an integrated graphical user interface to demonstrate the feasibility of the proposed methods.
A review of compliant transmission mechanisms for bio-inspired flapping-wing micro air vehicles.
Zhang, C; Rossi, C
2017-02-15
Flapping-wing micro air vehicles (FWMAVs) are a class of unmanned aircraft that imitate flight characteristics of natural organisms such as birds, bats, and insects, in order to achieve maximum flight efficiency and manoeuvrability. Designing proper mechanisms for flapping transmission is an extremely important aspect for FWMAVs. Compliant transmission mechanisms have been considered as an alternative to rigid transmission systems due to their lower the number of parts, thereby reducing the total weight, lower energy loss thanks to little or practically no friction among parts, and at the same time, being able to store and release mechanical power during the flapping cycle. In this paper, the state-of-the-art research in this field is dealt upon, highlighting open challenges and research topics. An optimization method for designing compliant transmission mechanisms inspired by the thoraxes of insects is also introduced.
Buckling of a stiff thin film on an elastic graded compliant substrate.
Chen, Zhou; Chen, Weiqiu; Song, Jizhou
2017-12-01
The buckling of a stiff film on a compliant substrate has attracted much attention due to its wide applications such as thin-film metrology, surface patterning and stretchable electronics. An analytical model is established for the buckling of a stiff thin film on a semi-infinite elastic graded compliant substrate subjected to in-plane compression. The critical compressive strain and buckling wavelength for the sinusoidal mode are obtained analytically for the case with the substrate modulus decaying exponentially. The rigorous finite element analysis (FEA) is performed to validate the analytical model and investigate the postbuckling behaviour of the system. The critical buckling strain for the period-doubling mode is obtained numerically. The influences of various material parameters on the results are investigated. These results are helpful to provide physical insights on the buckling of elastic graded substrate-supported thin film.
Quantification of regenerative potential in primary human mammary epithelial cells
Linnemann, Jelena R.; Miura, Haruko; Meixner, Lisa K.; Irmler, Martin; Kloos, Uwe J.; Hirschi, Benjamin; Bartsch, Harald S.; Sass, Steffen; Beckers, Johannes; Theis, Fabian J.; Gabka, Christian; Sotlar, Karl; Scheel, Christina H.
2015-01-01
We present an organoid regeneration assay in which freshly isolated human mammary epithelial cells are cultured in adherent or floating collagen gels, corresponding to a rigid or compliant matrix environment. In both conditions, luminal progenitors form spheres, whereas basal cells generate branched ductal structures. In compliant but not rigid collagen gels, branching ducts form alveoli at their tips, express basal and luminal markers at correct positions, and display contractility, which is required for alveologenesis. Thereby, branched structures generated in compliant collagen gels resemble terminal ductal-lobular units (TDLUs), the functional units of the mammary gland. Using the membrane metallo-endopeptidase CD10 as a surface marker enriches for TDLU formation and reveals the presence of stromal cells within the CD49fhi/EpCAM− population. In summary, we describe a defined in vitro assay system to quantify cells with regenerative potential and systematically investigate their interaction with the physical environment at distinct steps of morphogenesis. PMID:26071498
Buckling of a stiff thin film on an elastic graded compliant substrate
NASA Astrophysics Data System (ADS)
Chen, Zhou; Chen, Weiqiu; Song, Jizhou
2017-12-01
The buckling of a stiff film on a compliant substrate has attracted much attention due to its wide applications such as thin-film metrology, surface patterning and stretchable electronics. An analytical model is established for the buckling of a stiff thin film on a semi-infinite elastic graded compliant substrate subjected to in-plane compression. The critical compressive strain and buckling wavelength for the sinusoidal mode are obtained analytically for the case with the substrate modulus decaying exponentially. The rigorous finite element analysis (FEA) is performed to validate the analytical model and investigate the postbuckling behaviour of the system. The critical buckling strain for the period-doubling mode is obtained numerically. The influences of various material parameters on the results are investigated. These results are helpful to provide physical insights on the buckling of elastic graded substrate-supported thin film.
Seebregts, Christopher; Dane, Pierre; Parsons, Annie Neo; Fogwill, Thomas; Rogers, Debbie; Bekker, Marcha; Shaw, Vincent; Barron, Peter
2018-01-01
MomConnect is a national initiative coordinated by the South African National Department of Health that sends text-based mobile phone messages free of charge to pregnant women who voluntarily register at any public healthcare facility in South Africa. We describe the system design and architecture of the MomConnect technical platform, planned as a nationally scalable and extensible initiative. It uses a health information exchange that can connect any standards-compliant electronic front-end application to any standards-compliant electronic back-end database. The implementation of the MomConnect technical platform, in turn, is a national reference application for electronic interoperability in line with the South African National Health Normative Standards Framework. The use of open content and messaging standards enables the architecture to include any application adhering to the selected standards. Its national implementation at scale demonstrates both the use of this technology and a key objective of global health information systems, which is to achieve implementation scale. The system’s limited clinical information, initially, allowed the architecture to focus on the base standards and profiles for interoperability in a resource-constrained environment with limited connectivity and infrastructural capacity. Maintenance of the system requires mobilisation of national resources. Future work aims to use the standard interfaces to include data from additional applications as well as to extend and interface the framework with other public health information systems in South Africa. The development of this platform has also shown the benefits of interoperability at both an organisational and technical level in South Africa. PMID:29713506
Design of 3D-Printed Titanium Compliant Mechanisms
NASA Technical Reports Server (NTRS)
Merriam, Ezekiel G.; Jones, Jonathan E.; Howell, Larry L.
2014-01-01
This paper describes 3D-printed titanium compliant mechanisms for aerospace applications. It is meant as a primer to help engineers design compliant, multi-axis, printed parts that exhibit high performance. Topics covered include brief introductions to both compliant mechanism design and 3D printing in titanium, material and geometry considerations for 3D printing, modeling techniques, and case studies of both successful and unsuccessful part geometries. Key findings include recommended flexure geometries, minimum thicknesses, and general design guidelines for compliant printed parts that may not be obvious to the first time designer.
Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing
2013-01-01
Background Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930® is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. Methods The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient’s suitability for percutaneous pulmonary valve intervention. Results The distensibility of the material was identified in a range from 6.5 × 10-3 mmHg-1 for the 0.6 mm case, to 3.0 × 10-3 mmHg-1 for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Conclusion Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with the added benefit of being compatible with PolyJet printing, thus guaranteeing representative anatomical finishing, and quick and inexpensive fabrication. The appealing possibility of printing models of non-uniform wall thickness, resembling more closely certain physiological scenarios, can also be explored. However, this material appears to be too stiff for modelling the more compliant systemic venous system. PMID:23324211
Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.
Biglino, Giovanni; Verschueren, Peter; Zegels, Raf; Taylor, Andrew M; Schievano, Silvia
2013-01-16
Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930 is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient's suitability for percutaneous pulmonary valve intervention. The distensibility of the material was identified in a range from 6.5 × 10(-3) mmHg(-1) for the 0.6 mm case, to 3.0 × 10(-3) mmHg(-1) for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with the added benefit of being compatible with PolyJet printing, thus guaranteeing representative anatomical finishing, and quick and inexpensive fabrication. The appealing possibility of printing models of non-uniform wall thickness, resembling more closely certain physiological scenarios, can also be explored. However, this material appears to be too stiff for modelling the more compliant systemic venous system.
Nawasreh, Zakariya; Failla, Mathew; Marmon, Adam; Logerstedt, David; Snyder-Mackler, Lynn
2018-05-23
Performing physical activities on a compliant surface alters joint kinematics and increases joints stiffness. However, the effect of compliant surface on joint kinematics after ACL-rupture is yet unknown. To compare the effects of mechanical perturbation training with a compliant surface to manual perturbation training on joint kinematics after ACL-rupture. Sixteen level I/II athletes with ACL-rupture participated in this preliminary study. Eight patients received mechanical perturbation with compliant surface (Mechanical) and 8 patients received manual perturbation training (Manual). Patients completed standard gait analysis before (Pre) and after (Post) training. Significant group-by-time interactions were found for knee flexion angle at initial contact (IC) and peak knee flexion (PKF) (p<0.004), with manual group significantly increased knee flexion angle at IC and PKF (p<0.03). Main effects of group were found for hip flexion angle at IC (Manual:34.34+3.51°, Mechanical:27.68+4.08°, p = 0.011), hip rotation angle at PKE (Manual:-3.40+4.78°, Mechanical:5.43+4.78°, p < 0.0001), and knee adduction angle at PKE (Manual:-2.00+2.23°, Mechanical:0.55+2.23°, p = 0.039). Main effects of time were found for hip adduction angle at PKE (Pre:6.98+4.48°, Post:8.41+4.91°, p = 0.04), knee adduction angle at IC (Pre:-2.90+3.50°, Post:-0.62+2.58°, p = 0.03), ankle adduction angle at IC (Pre:2.16+3.54, Post:3.8+3.68, p = 0.008), and ankle flexion angle at PKF (Pre:-4.55+2.77°, Post:-2.39+3.48°, p = 0.01). Training on a compliant surface induces different effects on joint kinematics compared to manual perturbation training after ACL-rupture. Manual perturbation improved hip alignment and increased knee flexion angles, while mechanical training decreased knee flexion angles throughout the stance phase. Administering training on a compliant surface after ACL-rupture may help improving dynamic knee stability, however, long-term effects on knee health needs to be determined. Copyright © 2018 Elsevier B.V. All rights reserved.
2012-06-01
MISP) COMPLIANT ARCHITECTURE WHITE SANDS MISSILE RANGE REAGAN TEST SITE YUMA PROVING GROUND DUGWAY PROVING GROUND ABERDEEN TEST CENTER...DIGITAL MOTION IMAGERY COMPRESSION BEST PRACTICES GUIDE – A MOTION IMAGERY STANDARDS PROFILE (MISP) COMPLIANT ARCHITECTURE ...delivery, and archival purposes. These practices are based on a Motion Imagery Standards Profile (MISP) compliant architecture , which has been defined
ERIC Educational Resources Information Center
Pineda, Ernest M.
1999-01-01
Discusses ways to help resolve the Y2K problem and avoid disruptions in school security and safety. Discusses computer software testing and validation to determine its functionality after year's end, and explores system remediation of non-compliant fire and security systems. (GR)
HEMCO v1.0: A Versatile, ESMF-Compliant Component for Calculating Emissions in Atmospheric Models
NASA Technical Reports Server (NTRS)
Keller, C. A.; Long, M. S.; Yantosca, R. M.; Da Silva, A. M.; Pawson, S.; Jacob, D. J.
2014-01-01
We describe the Harvard-NASA Emission Component version 1.0 (HEMCO), a stand-alone software component for computing emissions in global atmospheric models. HEMCO determines emissions from different sources, regions, and species on a user-defined grid and can combine, overlay, and update a set of data inventories and scale factors, as specified by the user through the HEMCO configuration file. New emission inventories at any spatial and temporal resolution are readily added to HEMCO and can be accessed by the user without any preprocessing of the data files or modification of the source code. Emissions that depend on dynamic source types and local environmental variables such as wind speed or surface temperature are calculated in separate HEMCO extensions. HEMCO is fully compliant with the Earth System Modeling Framework (ESMF) environment. It is highly portable and can be deployed in a new model environment with only few adjustments at the top-level interface. So far, we have implemented HEMCO in the NASA Goddard Earth Observing System (GEOS-5) Earth system model (ESM) and in the GEOS-Chem chemical transport model (CTM). By providing a widely applicable framework for specifying constituent emissions, HEMCO is designed to ease sensitivity studies and model comparisons, as well as inverse modeling in which emissions are adjusted iteratively. The HEMCO code, extensions, and the full set of emissions data files used in GEOS-Chem are available at http: //wiki.geos-chem.org/HEMCO.
A behavioral rehabilitation intervention for amnestic Mild Cognitive Impairment
Greenaway, Melanie C.; Hanna, Sherrie M.; Lepore, Susan W.; Smith, Glenn E.
2010-01-01
Individuals with amnestic Mild Cognitive Impairment (MCI) currently have few treatment options for combating their memory loss. The Memory Support System (MSS) is a calendar and organization system with accompanying 6-week curriculum designed for individuals with progressive memory impairment. Ability to learn the MSS and its utility were assessed in 20 participants. Participants were significantly more likely to successfully use the calendar system after training. Ninety-five percent were compliant with the MSS at training completion, and 89% continued to be compliant at follow-up. Outcome measures revealed a medium effect size for improvement in functional ability. Subjects further reported improved independence, self-confidence, and mood. This initial examination of the MSS suggests that with appropriate training, individuals with amnestic MCI can and will use a memory notebook system to help compensate for memory loss. These results are encouraging that the MSS may help with the symptoms of memory decline in MCI. PMID:18955724
Development of a low mobility IEEE 802.15.4 compliant VANET system for urban environments.
Nazabal, Juan Antonio; Falcone, Francisco; Fernández-Valdivielso, Carlos; Matías, Ignacio Raúl
2013-05-29
The use of Vehicular Ad-Hoc Networks (VANETs) is growing nowadays and it includes both roadside-to-vehicle communication (RVC) and inter-vehicle communication (IVC). The purpose of VANETs is to exchange useful information between vehicles and the roadside infrastructures for making an intelligent use of them. There are several possible applications for this technology like: emergency warning system for vehicles, cooperative adaptive cruise control or collision avoidance, among others. The objective of this work is to develop a VANET prototype system for urban environments using IEEE 802.15.4 compliant devices. Simulation-based values of the estimated signal strength and radio link quality values are obtained and compared with measurements in outdoor conditions to validate an implemented VANET system. The results confirm the possibility of implementing low cost vehicular communication networks operating at moderate vehicular speeds.
Rotman, Oren Moshe; Weiss, Dar; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel
2015-09-18
High accuracy differential pressure measurements are required in various biomedical and medical applications, such as in fluid-dynamic test systems, or in the cath-lab. Differential pressure measurements using fluid-filled catheters are relatively inexpensive, yet may be subjected to common mode pressure errors (CMP), which can significantly reduce the measurement accuracy. Recently, a novel correction method for high accuracy differential pressure measurements was presented, and was shown to effectively remove CMP distortions from measurements acquired in rigid tubes. The purpose of the present study was to test the feasibility of this correction method inside compliant tubes, which effectively simulate arteries. Two tubes with varying compliance were tested under dynamic flow and pressure conditions to cover the physiological range of radial distensibility in coronary arteries. A third, compliant model, with a 70% stenosis severity was additionally tested. Differential pressure measurements were acquired over a 3 cm tube length using a fluid-filled double-lumen catheter, and were corrected using the proposed CMP correction method. Validation of the corrected differential pressure signals was performed by comparison to differential pressure recordings taken via a direct connection to the compliant tubes, and by comparison to predicted differential pressure readings of matching fluid-structure interaction (FSI) computational simulations. The results show excellent agreement between the experimentally acquired and computationally determined differential pressure signals. This validates the application of the CMP correction method in compliant tubes of the physiological range for up to intermediate size stenosis severity of 70%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Variation simulation for compliant sheet metal assemblies with applications
NASA Astrophysics Data System (ADS)
Long, Yufeng
Sheet metals are widely used in discrete products, such as automobiles, aircraft, furniture and electronics appliances, due to their good manufacturability and low cost. A typical automotive body assembly consists of more than 300 parts welded together in more than 200 assembly fixture stations. Such an assembly system is usually quite complex, and takes a long time to develop. As the automotive customer demands products of increasing quality in a shorter time, engineers in automotive industry turn to computer-aided engineering (CAE) tools for help. Computers are an invaluable resource for engineers, not only to simplify and automate the design process, but also to share design specifications with manufacturing groups so that production systems can be tooled up quickly and efficiently. Therefore, it is beneficial to develop computerized simulation and evaluation tools for development of automotive body assembly systems. It is a well-known fact that assembly architectures (joints, fixtures, and assembly lines) have a profound impact on dimensional quality of compliant sheet metal assemblies. To evaluate sheet metal assembly architectures, a special dimensional analysis tool need be developed for predicting dimensional variation of the assembly. Then, the corresponding systematic tools can be established to help engineers select the assembly architectures. In this dissertation, a unified variation model is developed to predict variation in compliant sheet metal assemblies by considering fixture-induced rigid-body motion, deformation and springback. Based on the unified variation model, variation propagation models in multiple assembly stations with various configurations are established. To evaluate the dimensional capability of assembly architectures, quantitative indices are proposed based on the sensitivity matrix, which are independent of the variation level of the process. Examples are given to demonstrate their applications in selecting robust assembly architectures, and some useful guidelines for selection of assembly architectures are summarized. In addition, to enhance the fault diagnosis, a systematic methodology is proposed for selection of measurement configurations. Specifically, principles involved in selecting measurements are generalized first; then, the corresponding quantitative indices are developed to evaluate the measurement configurations, and finally, examples are present.
Flectofold—a biomimetic compliant shading device for complex free form facades
NASA Astrophysics Data System (ADS)
Körner, A.; Born, L.; Mader, A.; Sachse, R.; Saffarian, S.; Westermeier, A. S.; Poppinga, S.; Bischoff, M.; Gresser, G. T.; Milwich, M.; Speck, T.; Knippers, J.
2018-01-01
Smart and adaptive outer façade shading systems are of high interest in modern architecture. For long lasting and reliable systems, the abandonment of hinges which often fail due to mechanical wear during repetitive use is of particular importance. Drawing inspiration from the hinge-less motion of the underwater snap-trap of the carnivorous waterwheel plant (Aldrovanda vesiculosa), the compliant façade shading device Flectofold was developed. Based on computational simulations of the biological role-model’s elastic and reversible motion, the actuation principle of the plant can be identified. The enclosed geometric motion principle is abstracted into a simplified curved-line folding geometry with distinct flexible hinge-zones. The kinematic behaviour is translated into a quantitative kinetic model, using finite element simulation which allows the detailed analyses of the influence of geometric parameters such as curved-fold line radius and various pneumatically driven actuation principles on the motion behaviour, stress concentrations within the hinge-zones, and actuation forces. The information regarding geometric relations and material gradients gained from those computational models are then used to develop novel material combinations for glass fibre reinforced plastics which enabled the fabrication of physical prototypes of the compliant façade shading device Flectofold.
Uchida, Thomas K.; Sherman, Michael A.; Delp, Scott L.
2015-01-01
Impacts are instantaneous, computationally efficient approximations of collisions. Current impact models sacrifice important physical principles to achieve that efficiency, yielding qualitative and quantitative errors when applied to simultaneous impacts in spatial multibody systems. We present a new impact model that produces behaviour similar to that of a detailed compliant contact model, while retaining the efficiency of an instantaneous method. In our model, time and configuration are fixed, but the impact is resolved into distinct compression and expansion phases, themselves comprising sliding and rolling intervals. A constrained optimization problem is solved for each interval to compute incremental impulses while respecting physical laws and principles of contact mechanics. We present the mathematical model, algorithms for its practical implementation, and examples that demonstrate its effectiveness. In collisions involving materials of various stiffnesses, our model can be more than 20 times faster than integrating through the collision using a compliant contact model. This work extends the use of instantaneous impact models to scientific and engineering applications with strict accuracy requirements, where compliant contact models would otherwise be required. An open-source implementation is available in Simbody, a C++ multibody dynamics library widely used in biomechanical and robotic applications. PMID:27547093
Compliant threads maximize spider silk connection strength and toughness
Meyer, Avery; Pugno, Nicola M.; Cranford, Steven W.
2014-01-01
Millions of years of evolution have adapted spider webs to achieve a range of functionalities, including the well-known capture of prey, with efficient use of material. One feature that has escaped extensive investigation is the silk-on-silk connection joints within spider webs, particularly from a structural mechanics perspective. We report a joint theoretical and computational analysis of an idealized silk-on-silk fibre junction. By modifying the theory of multiple peeling, we quantitatively compare the performance of the system while systematically increasing the rigidity of the anchor thread, by both scaling the stress–strain response and the introduction of an applied pre-strain. The results of our study indicate that compliance is a virtue—the more extensible the anchorage, the tougher and stronger the connection becomes. In consideration of the theoretical model, in comparison with rigid substrates, a compliant anchorage enormously increases the effective adhesion strength (work required to detach), independent of the adhered thread itself, attributed to a nonlinear alignment between thread and anchor (contact peeling angle). The results can direct novel engineering design principles to achieve possible load transfer from compliant fibre-to-fibre anchorages, be they silk-on-silk or another, as-yet undeveloped, system. PMID:25008083
Self-similar and fractal design for stretchable electronics
Rogers, John A.; Fan, Jonathan; Yeo, Woon-Hong; Su, Yewang; Huang, Yonggang; Zhang, Yihui
2017-04-04
The present invention provides electronic circuits, devices and device components including one or more stretchable components, such as stretchable electrical interconnects, electrodes and/or semiconductor components. Stretchability of some of the present systems is achieved via a materials level integration of stretchable metallic or semiconducting structures with soft, elastomeric materials in a configuration allowing for elastic deformations to occur in a repeatable and well-defined way. The stretchable device geometries and hard-soft materials integration approaches of the invention provide a combination of advance electronic function and compliant mechanics supporting a broad range of device applications including sensing, actuation, power storage and communications.
NASA Technical Reports Server (NTRS)
Rios, Joseph
2012-01-01
Presenting the current status of the Digital TMI project to visiting members of the FAA Command Center. Digital TMI is an effort to store national-level traffic management initiatives in a standards-compliant manner. Work is funded by the FAA.
NASA Astrophysics Data System (ADS)
Zhu, Wu-Le; Zhu, Zhiwei; To, Suet; Liu, Qiang; Ju, Bing-Feng; Zhou, Xiaoqin
2016-12-01
This paper presents a novel redundantly piezo-actuated three-degree-of-freedom XYθ z compliant mechanism for nano-positioning, driven by four mirror-symmetrically configured piezoelectric actuators (PEAs). By means of differential motion principle, linearized kinematics and physically bi-directional motions in all the three directions are achieved. Meanwhile, the decoupled delivering of three-directional independent motions at the output end is accessible, and the essential parallel and mirror symmetric configuration guarantees large output stiffness, high natural frequencies, high accuracy as well as high structural compactness of the mechanism. Accurate kinematics analysis with consideration of input coupling indicates that the proposed redundantly actuated compliant mechanism can generate three-dimensional (3D) symmetric polyhedral workspace envelope with enlarged reachable workspace, as compared with the most common parallel XYθ z mechanism driven by three PEAs. Keeping a high consistence with both analytical and numerical models, the experimental results show the working ranges of ±6.21 μm and ±12.41 μm in X- and Y-directions, and that of ±873.2 μrad in θ z-direction with nano-positioning capability can be realized. The superior performances and easily achievable structure well facilitate practical applications of the proposed XYθ z compliant mechanism in nano-positioning systems.
Development of an IHE MRRT-compliant open-source web-based reporting platform.
Pinto Dos Santos, Daniel; Klos, G; Kloeckner, R; Oberle, R; Dueber, C; Mildenberger, P
2017-01-01
To develop a platform that uses structured reporting templates according to the IHE Management of Radiology Report Templates (MRRT) profile, and to implement this platform into clinical routine. The reporting platform uses standard web technologies (HTML / JavaScript and PHP / MySQL) only. Several freely available external libraries were used to simplify the programming. The platform runs on a standard web server, connects with the radiology information system (RIS) and PACS, and is easily accessible via a standard web browser. A prototype platform that allows structured reporting to be easily incorporated into the clinical routine was developed and successfully tested. To date, 797 reports were generated using IHE MRRT-compliant templates (many of them downloaded from the RSNA's radreport.org website). Reports are stored in a MySQL database and are easily accessible for further analyses. Development of an IHE MRRT-compliant platform for structured reporting is feasible using only standard web technologies. All source code will be made available upon request under a free license, and the participation of other institutions in further development is welcome. • A platform for structured reporting using IHE MRRT-compliant templates is presented. • Incorporating structured reporting into clinical routine is feasible. • Full source code will be provided upon request under a free license.
Can compliant fault zones be used to measure absolute stresses in the upper crust?
NASA Astrophysics Data System (ADS)
Hearn, E. H.; Fialko, Y.
2009-04-01
Geodetic and seismic observations reveal long-lived zones with reduced elastic moduli along active crustal faults. These fault zones localize strain from nearby earthquakes, consistent with the response of a compliant, elastic layer. Fault zone trapped wave studies documented a small reduction in P and S wave velocities along the Johnson Valley Fault caused by the 1999 Hector Mine earthquake. This reduction presumably perturbed a permanent compliant structure associated with the fault. The inferred changes in the fault zone compliance may produce a measurable deformation in response to background (tectonic) stresses. This deformation should have the same sense as the background stress, rather than the coseismic stress change. Here we investigate how the observed deformation of compliant zones in the Mojave Desert can be used to constrain the fault zone structure and stresses in the upper crust. We find that gravitational contraction of the coseismically softened zones should cause centimeters of coseismic subsidence of both the compliant zones and the surrounding region, unless the compliant fault zones are shallow and narrow, or essentially incompressible. We prefer the latter interpretation because profiles of line of sight displacements across compliant zones cannot be fit by a narrow, shallow compliant zone. Strain of the Camp Rock and Pinto Mountain fault zones during the Hector Mine and Landers earthquakes suggests that background deviatoric stresses are broadly consistent with Mohr-Coulomb theory in the Mojave upper crust (with μ ≥ 0.7). Large uncertainties in Mojave compliant zone properties and geometry preclude more precise estimates of crustal stresses in this region. With improved imaging of the geometry and elastic properties of compliant zones, and with precise measurements of their strain in response to future earthquakes, the modeling approach we describe here may eventually provide robust estimates of absolute crustal stress.
Krisciunas, Gintas P; Castellano, Kerlly; McCulloch, Timothy M; Lazarus, Cathy L; Pauloski, Barbara R; Meyer, Tanya K; Graner, Darlene; Van Daele, Douglas J; Silbergleit, Alice K; Crujido, Lisa R; Rybin, Denis; Doros, Gheorghe; Kotz, Tamar; Langmore, Susan E
2017-04-01
A 5-year, 16-site, randomized controlled trial enrolled 170 HNC survivors into active (estim + swallow exercise) or control (sham estim + swallowing exercise) arms. Primary analyses showed that estim did not enhance swallowing exercises. This secondary analysis determined if/how patient compliance impacted outcomes. A home program, performed 2 times/day, 6 days/week, for 12 weeks included stretches and 60 swallows paired with real or sham estim. Regular clinic visits ensured proper exercise execution, and detailed therapy checklists tracked patient compliance which was defined by mean number of sessions performed per week (0-12 times) over the 12-week intervention period. "Compliant" was defined as performing 10-12 sessions/week. Outcomes were changes in PAS, HNCI, PSS, OPSE, and hyoid excursion. ANCOVA analyses determined if outcomes differed between real/sham and compliant/noncompliant groups after 12 weeks of therapy. Of the 170 patients enrolled, 153 patients had compliance data. The mean number of sessions performed was 8.57/week (median = 10.25). Fifty-four percent of patients (n = 83) were considered "compliant." After 12 weeks of therapy, compliant patients in the sham estim group realized significantly better PAS scores than compliant patients in the active estim group (p = 0.0074). When pooling all patients together, there were no significant differences in outcomes between compliant and non-compliant patients. The addition of estim to swallowing exercises resulted in worse swallowing outcomes than exercises alone, which was more pronounced in compliant patients. Since neither compliant nor non-compliant patients benefitted from swallowing exercises, the proper dose and/or efficacy of swallowing exercises must also be questioned in this patient population.
Sea Surface Temperature Products and Research Associated with GHRSST
NASA Astrophysics Data System (ADS)
Kaiser-Weiss, Andrea K.; Minnett, Peter J.; Kaplan, Alexey; Wick, Gary A.; Castro, Sandra; Llewellyn-Jones, David; Merchant, Chris; LeBorgne, Pierre; Beggs, Helen; Donlon, Craig J.
2012-03-01
GHRSST serves its user community through the specification of operational Sea Surface Temperature (SST) products (Level 2, Level 3 and Level 4) based on international consensus. Providers of SST data from individual satellites create and deliver GHRSST-compliant near-real time products to a global GHRSST data assembly centre and a long-term stewardship facility. The GHRSST-compliant data include error estimates and supporting data for interpretation. Groups organised within GHRSST perform research on issues relevant to applying SST for air-sea exchange, for instance the Diurnal Variability Working Group (DVWG) analyses the evolution of the skin temperature. Other GHRSST groups concentrate on improving the SST estimate (Estimation and Retrievals Working Group EARWiG) and on improving the error characterization, (Satellite SST Validation Group, ST-VAL) and on improving the methods for SST analysis (Inter-Comparison Technical Advisory Group, IC-TAG). In this presentation we cover the data products and the scientific activities associated with GHRSST which might be relevant for investigating ocean-atmosphere interactions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... FOR COMPLIANT CONDUCT AND RESPONSIBLE USE OF THE INTERSTATE IDENTIFICATION INDEX (III) SYSTEM FOR NONCRIMINAL JUSTICE PURPOSES § 907.2 Applicability. This rule applies to III System access for noncriminal... by means of the System for such purposes. The rule establishes procedures for ensuring that the FBI's...
Code of Federal Regulations, 2014 CFR
2014-07-01
... FOR COMPLIANT CONDUCT AND RESPONSIBLE USE OF THE INTERSTATE IDENTIFICATION INDEX (III) SYSTEM FOR NONCRIMINAL JUSTICE PURPOSES § 907.2 Applicability. This rule applies to III System access for noncriminal... by means of the System for such purposes. The rule establishes procedures for ensuring that the FBI's...
Code of Federal Regulations, 2011 CFR
2011-07-01
... FOR COMPLIANT CONDUCT AND RESPONSIBLE USE OF THE INTERSTATE IDENTIFICATION INDEX (III) SYSTEM FOR NONCRIMINAL JUSTICE PURPOSES § 907.2 Applicability. This rule applies to III System access for noncriminal... by means of the System for such purposes. The rule establishes procedures for ensuring that the FBI's...
Code of Federal Regulations, 2010 CFR
2010-07-01
... FOR COMPLIANT CONDUCT AND RESPONSIBLE USE OF THE INTERSTATE IDENTIFICATION INDEX (III) SYSTEM FOR NONCRIMINAL JUSTICE PURPOSES § 907.2 Applicability. This rule applies to III System access for noncriminal... by means of the System for such purposes. The rule establishes procedures for ensuring that the FBI's...
Code of Federal Regulations, 2013 CFR
2013-07-01
... FOR COMPLIANT CONDUCT AND RESPONSIBLE USE OF THE INTERSTATE IDENTIFICATION INDEX (III) SYSTEM FOR NONCRIMINAL JUSTICE PURPOSES § 907.2 Applicability. This rule applies to III System access for noncriminal... by means of the System for such purposes. The rule establishes procedures for ensuring that the FBI's...
Passive Thermal Management of Foil Bearings
NASA Technical Reports Server (NTRS)
Bruckner, Robert J. (Inventor)
2015-01-01
Systems and methods for passive thermal management of foil bearing systems are disclosed herein. The flow of the hydrodynamic film across the surface of bearing compliant foils may be disrupted to provide passive cooling and to improve the performance and reliability of the foil bearing system.
Aerostructural optimization of a morphing wing for airborne wind energy applications
NASA Astrophysics Data System (ADS)
Fasel, U.; Keidel, D.; Molinari, G.; Ermanni, P.
2017-09-01
Airborne wind energy (AWE) vehicles maximize energy production by constantly operating at extreme wing loading, permitted by high flight speeds. Additionally, the wide range of wind speeds and the presence of flow inhomogeneities and gusts create a complex and demanding flight environment for AWE systems. Adaptation to different flow conditions is normally achieved by conventional wing control surfaces and, in case of ground generator-based systems, by varying the reel-out speed. These control degrees of freedom enable to remain within the operational envelope, but cause significant penalties in terms of energy output. A significantly greater adaptability is offered by shape-morphing wings, which have the potential to achieve optimal performance at different flight conditions by tailoring their airfoil shape and lift distribution at different levels along the wingspan. Hence, the application of compliant structures for AWE wings is very promising. Furthermore, active gust load alleviation can be achieved through morphing, which leads to a lower weight and an expanded flight envelope, thus increasing the power production of the AWE system. This work presents a procedure to concurrently optimize the aerodynamic shape, compliant structure, and composite layup of a morphing wing for AWE applications. The morphing concept is based on distributed compliance ribs, actuated by electromechanical linear actuators, guiding the deformation of the flexible—yet load-carrying—composite skin. The goal of the aerostructural optimization is formulated as a high-level requirement, namely to maximize the average annual power production per wing area of an AWE system by tailoring the shape of the wing, and to extend the flight envelope of the wing by actively alleviating gust loads. The results of the concurrent multidisciplinary optimization show a 50.7% increase of extracted power with respect to a sequentially optimized design, highlighting the benefits of morphing and the potential of the proposed approach.
An overview on STEP-NC compliant controller development
NASA Astrophysics Data System (ADS)
Othman, M. A.; Minhat, M.; Jamaludin, Z.
2017-10-01
The capabilities of conventional Computer Numerical Control (CNC) machine tools as termination organiser to fabricate high-quality parts promptly, economically and precisely are undeniable. To date, most CNCs follow the programming standard of ISO 6983, also called G & M code. However, in fluctuating shop floor environment, flexibility and interoperability of current CNC system to react dynamically and adaptively are believed still limited. This outdated programming language does not explicitly relate to each other to have control of arbitrary locations other than the motion of the block-by-block. To address this limitation, new standard known as STEP-NC was developed in late 1990s and is formalized as an ISO 14649. It adds intelligence to the CNC in term of interoperability, flexibility, adaptability and openness. This paper presents an overview of the research work that have been done in developing a STEP-NC controller standard and the capabilities of STEP-NC to overcome modern manufacturing demands. Reviews stated that most existing STEP-NC controller prototypes are based on type 1 and type 2 implementation levels. There are still lack of effort being done to develop type 3 and type 4 STEP-NC compliant controller.
Year 2000 Computing Crisis: FAA Must Act Quickly to Prevent System Failures
DOT National Transportation Integrated Search
1998-02-01
Testimony before House of Representatives on FAA's reliance on information processing, where the agency stood remained at risk, and recommendations needed to increase the likelihood that FAA systems would be Year 2000 compliant by January.
Drag reduction through self-texturing compliant bionic materials
Liu, Eryong; Li, Longyang; Wang, Gang; Zeng, Zhixiang; Zhao, Wenjie; Xue, Qunji
2017-01-01
Compliant fish skin is effectively in reducing drag, thus the design and application of compliant bionic materials may be a good choice for drag reduction. Here we consider the drag reduction of compliant bionic materials. First, ZnO and PDMS mesh modified with n-octadecane were prepared, the drag reduction of self-texturing compliant n-octadecane were studied. The results show that the mesh modified by ZnO and PDMS possess excellent lipophilic and hydrophobic, thus n-octadecane at solid, semisolid and liquid state all have good adhesion with modified mesh. The states of n-octadecane changed with temperature, thus, the surface contact angle and adhesive force all varies obviously at different state. The contact angle decreases with temperature, the adhesive force shows a lower value at semisolid state. Furthermore, the drag testing results show that the compliant n-octadecane film is more effectively in drag reduction than superhydrophobic ZnO/PDMS film, indicating that the drag reduction mechanism of n-octadecane is significantly different with superhydrophobic film. Further research shows that the water flow leads to self-texturing of semisolid state n-octadecane, which is similar with compliant fish skin. Therefore, the compliant bionic materials of semisolid state n-octadecane with regular bulge plays a major role in the drag reduction. PMID:28053309
Drag reduction through self-texturing compliant bionic materials.
Liu, Eryong; Li, Longyang; Wang, Gang; Zeng, Zhixiang; Zhao, Wenjie; Xue, Qunji
2017-01-05
Compliant fish skin is effectively in reducing drag, thus the design and application of compliant bionic materials may be a good choice for drag reduction. Here we consider the drag reduction of compliant bionic materials. First, ZnO and PDMS mesh modified with n-octadecane were prepared, the drag reduction of self-texturing compliant n-octadecane were studied. The results show that the mesh modified by ZnO and PDMS possess excellent lipophilic and hydrophobic, thus n-octadecane at solid, semisolid and liquid state all have good adhesion with modified mesh. The states of n-octadecane changed with temperature, thus, the surface contact angle and adhesive force all varies obviously at different state. The contact angle decreases with temperature, the adhesive force shows a lower value at semisolid state. Furthermore, the drag testing results show that the compliant n-octadecane film is more effectively in drag reduction than superhydrophobic ZnO/PDMS film, indicating that the drag reduction mechanism of n-octadecane is significantly different with superhydrophobic film. Further research shows that the water flow leads to self-texturing of semisolid state n-octadecane, which is similar with compliant fish skin. Therefore, the compliant bionic materials of semisolid state n-octadecane with regular bulge plays a major role in the drag reduction.
Drag reduction through self-texturing compliant bionic materials
NASA Astrophysics Data System (ADS)
Liu, Eryong; Li, Longyang; Wang, Gang; Zeng, Zhixiang; Zhao, Wenjie; Xue, Qunji
2017-01-01
Compliant fish skin is effectively in reducing drag, thus the design and application of compliant bionic materials may be a good choice for drag reduction. Here we consider the drag reduction of compliant bionic materials. First, ZnO and PDMS mesh modified with n-octadecane were prepared, the drag reduction of self-texturing compliant n-octadecane were studied. The results show that the mesh modified by ZnO and PDMS possess excellent lipophilic and hydrophobic, thus n-octadecane at solid, semisolid and liquid state all have good adhesion with modified mesh. The states of n-octadecane changed with temperature, thus, the surface contact angle and adhesive force all varies obviously at different state. The contact angle decreases with temperature, the adhesive force shows a lower value at semisolid state. Furthermore, the drag testing results show that the compliant n-octadecane film is more effectively in drag reduction than superhydrophobic ZnO/PDMS film, indicating that the drag reduction mechanism of n-octadecane is significantly different with superhydrophobic film. Further research shows that the water flow leads to self-texturing of semisolid state n-octadecane, which is similar with compliant fish skin. Therefore, the compliant bionic materials of semisolid state n-octadecane with regular bulge plays a major role in the drag reduction.
Wong, Kaitlyn E; Gorton, George E; Tashjian, David B; Tirabassi, Michael V; Moriarty, Kevin P
2014-06-01
The purpose of this study is to measure the effectiveness of compressive orthotic brace therapy for the treatment of pectus carinatum using an adjusted Haller Index (HI) measurement calculated from 3D body scan (BS) images. Pediatric patients with pectus carinatum were treated with either compressive orthotic bracing or observation. An adjusted BS Haller index (HI) was calculated from serial 3D BS images obtained on all patients. Medical records were evaluated to determine treatment with bracing and brace compliance more than 12hours daily. Compliant patient measurements were compared to non-compliant and non-brace groups. Forty patients underwent compressive orthotic bracing, while ten were observed. Twenty-three patients were compliant with bracing, and seventeen patients were non-compliant. Compliant patients exhibited an 8.2% increase, non-compliant patients had a 1.5% increase, and non-brace patients exhibited a 2.5% increase in BS HI. The change in BS HI of compliant patients was significantly different compared to non-brace patients (p=0.004) and non-compliant patients (p<0.001). Three dimensional BS is an effective, radiation free, and objective means to evaluate patients treated with compressive orthotic bracing. Copyright © 2014 Elsevier Inc. All rights reserved.
Compliance control with embedded neural elements
NASA Technical Reports Server (NTRS)
Venkataraman, S. T.; Gulati, S.
1992-01-01
The authors discuss a control approach that embeds the neural elements within a model-based compliant control architecture for robotic tasks that involve contact with unstructured environments. Compliance control experiments have been performed on actual robotics hardware to demonstrate the performance of contact control schemes with neural elements. System parameters were identified under the assumption that environment dynamics have a fixed nonlinear structure. A robotics research arm, placed in contact with a single degree-of-freedom electromechanical environment dynamics emulator, was commanded to move through a desired trajectory. The command was implemented by using a compliant control strategy.
A Compliant Casing for Transonic Axial Compressors
NASA Technical Reports Server (NTRS)
Bloch, Gregory S.; Hah, Chunill
2003-01-01
A viewgraph presentation on the concept of compliant casing for transonic axial compressors is shown. The topics include: 1) Concept for compliant casing; 2) Rig and facility details; 3) Experimental results; and 4) Numerical results.
[Compliance and resistance to child vaccination: a study among Swiss mothers].
Burton-Jeangros, C; Golay, M; Sudre, P
2005-09-01
This study examines mothers' practices and attitudes in relation to their child's immunization. In this area, like in others, gaps are being observed between the public health model of risk management and the population expectations and behaviors. Data were collected using a standardized questionnaire from 1295 women having, in 1999, one child between 7 and 8 years of age of Swiss nationality and attending the public school system in Geneva. Four immunization types were established based on (1) the degree of satisfaction (in relation to past choices), (2) the perception of adequate knowledge about immunization and (3) practices. The mothers were divided into the following categories: compliant (57%), compliant ambivalent (19%), moderately resistant (17%) and resistant (7%). Mothers having reached an intermediate education level are more likely to be resistant. Furthermore, women having negative attitudes towards biomedical institutions, having consulted alternative practitioners and those considering that they have a certain individual control over the health of the family are more often resistant to immunization. Our results confirm the existence of a resistance to child immunization among a section of the population. It should not be attributed to mothers' ignorance, but rather could reflect their perplexity towards the choices they are expected to make. In that regards, the importance some parents give to individual control over health can be in contradiction with community objectives of public health. Actions for the promotion of immunization should primarily target families who are uncertain (compliant ambivalent and moderately resistant). At the same time, the difficulties entailed in the - individual and collective - management of risks require that new forms of dialogue be developed between experts and the public.
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2018-09-01
Purpose-designed compliant flooring and carpeting have been promoted as a means for reducing fall-related injuries in high-risk environments, such as long-term care. However, it is not known whether these surfaces influence the forces that long-term care staff exert when pushing residents in wheelchairs. We studied 14 direct-care staff who pushed a loaded wheelchair instrumented with a triaxial load cell to test the effects on hand force of flooring overlay (vinyl versus carpet) and flooring subfloor (concrete versus compliant rubber [brand: SmartCells]). During straight-line pushing, carpet overlay increased initial and sustained hand forces compared to vinyl overlay by 22-49% over a concrete subfloor and by 8-20% over a compliant subfloor. Compliant subflooring increased initial and sustained hand forces compared to concrete subflooring by 18-31% when under a vinyl overlay. In contrast, compliant flooring caused no change in initial or sustained hand forces compared to concrete subflooring when under a carpet overlay. Copyright © 2018 Elsevier Ltd. All rights reserved.
van Berkel, Jantien; Boot, Cécile R L; Proper, Karin I; Bongers, Paulien M; van der Beek, Allard J
2013-01-01
To evaluate the process of the implementation of an intervention aimed at improving work engagement and energy balance, and to explore associations between process measures and compliance. Process measures were assessed using a combination of quantitative and qualitative methods. The mindfulness training was attended at least once by 81.3% of subjects, and 54.5% were highly compliant. With regard to e-coaching and homework exercises, 6.3% and 8.0%, respectively, were highly compliant. The training was appreciated with a 7.5 score and e-coaching with a 6.8 score. Appreciation of training and e-coaching, satisfaction with trainer and coach, and practical facilitation were significantly associated with compliance. The intervention was implemented well on the level of the mindfulness training, but poorly on the level of e-coaching and homework time investment. To increase compliance, attention should be paid to satisfaction and trainer-participant relationship.
Engineering risk reduction in satellite programs
NASA Technical Reports Server (NTRS)
Dean, E. S., Jr.
1979-01-01
Methods developed in planning and executing system safety engineering programs for Lockheed satellite integration contracts are presented. These procedures establish the applicable safety design criteria, document design compliance and assess the residual risks where non-compliant design is proposed, and provide for hazard analysis of system level test, handling and launch preparations. Operations hazard analysis identifies product protection and product liability hazards prior to the preparation of operational procedures and provides safety requirements for inclusion in them. The method developed for documenting all residual hazards for the attention of program management assures an acceptable minimum level of risk prior to program deployment. The results are significant for persons responsible for managing or engineering the deployment and production of complex high cost equipment under current product liability law and cost/time constraints, have a responsibility to minimize the possibility of an accident, and should have documentation to provide a defense in a product liability suit.
Framework and Method for Controlling a Robotic System Using a Distributed Computer Network
NASA Technical Reports Server (NTRS)
Sanders, Adam M. (Inventor); Strawser, Philip A. (Inventor); Barajas, Leandro G. (Inventor); Permenter, Frank Noble (Inventor)
2015-01-01
A robotic system for performing an autonomous task includes a humanoid robot having a plurality of compliant robotic joints, actuators, and other integrated system devices that are controllable in response to control data from various control points, and having sensors for measuring feedback data at the control points. The system includes a multi-level distributed control framework (DCF) for controlling the integrated system components over multiple high-speed communication networks. The DCF has a plurality of first controllers each embedded in a respective one of the integrated system components, e.g., the robotic joints, a second controller coordinating the components via the first controllers, and a third controller for transmitting a signal commanding performance of the autonomous task to the second controller. The DCF virtually centralizes all of the control data and the feedback data in a single location to facilitate control of the robot across the multiple communication networks.
xLuna - D emonstrator on ESA Mars Rover
NASA Astrophysics Data System (ADS)
Braga, P.; Henriques, L.; Carvalho, B.; Chevalley, P.; Zulianello, M.
2008-08-01
There is a significant gap between the services offered by existing space qualified Real-Time Operating Systems (RTOS) and those required by the most demanding future space applications. New requirements for autonomy, terrain mapping and navigation, Simultaneous Location and Mapping (SLAM), improvement of the throughput of science tasks, all demand high level services such as file systems or POSIX compliant interfaces. xLuna is an operating system that aims fulfilling these new requirements. Besides providing the typical services that of an RTOS (tasks and interrupts management, timers, message queues, etc), it also includes most of the features available in modern general-purpose operating systems, such as Linux. This paper describes a case study that proposes to demonstrate the usage of xLuna on board a rover currently in use for the development of algorithms in preparation of a mission to Mars.
802.16e System Profile for NASA Extra-Vehicular Activities
NASA Technical Reports Server (NTRS)
Foore, Lawrence R.; Chelmins, David T.; Nguyen, Hung D.; Downey, Joseph A.; Finn, Gregory G.; Cagley, Richard E.; Bakula, Casey J.
2009-01-01
This report identifies an 802.16e system profile that is applicable to a lunar surface wireless network, and specifically for meeting extra-vehicular activity (EVA) data flow requirements. EVA suit communication needs are addressed. Design-driving operational scenarios are considered. These scenarios are then used to identify a configuration of the 802.16e system (system profile) that meets EVA requirements, but also aim to make the radio realizable within EVA constraints. Limitations of this system configuration are highlighted. An overview and development status is presented by Toyon Research Corporation concerning the development of an 802.16e compatible modem under NASA s Small Business Innovative Research (SBIR) Program. This modem is based on the recommended system profile developed as part of this report. Last, a path forward is outlined that presents an evolvable solution for the EVA radio system and lunar surface radio networks. This solution is based on a custom link layer, and 802.16e compliant physical layer compliant to the identified system profile, and a later progression to a fully interoperable 802.16e system.
X-Windows Widget for Image Display
NASA Technical Reports Server (NTRS)
Deen, Robert G.
2011-01-01
XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.
Masia, Lorenzo; Cappello, Leonardo; Morasso, Pietro; Lachenal, Xavier; Pirrera, Alberto; Weaver, Paul; Mattioni, Filippo
2013-06-01
A novel actuator is introduced that combines an elastically compliant composite structure with conventional electromechanical elements. The proposed design is analogous to that used in Series Elastic Actuators, its distinctive feature being that the compliant composite part offers different stable configurations. In other words, its elastic potential presents points of local minima that correspond to robust stable positions (multistability). This potential is known a priori as a function of the structural geometry, thus providing tremendous benefits in terms of control implementation. Such knowledge enables the complexities arising from the additional degrees of freedom associated with link deformations to be overcome and uncover challenges that extends beyond those posed by standard rigidlink robot dynamics. It is thought that integrating a multistable elastic element in a robotic transmission can provide new scenarios in the field of assistive robotics, as the system may help a subject to stand or carry a load without the need for an active control effort by the actuators.
Quantification of regenerative potential in primary human mammary epithelial cells.
Linnemann, Jelena R; Miura, Haruko; Meixner, Lisa K; Irmler, Martin; Kloos, Uwe J; Hirschi, Benjamin; Bartsch, Harald S; Sass, Steffen; Beckers, Johannes; Theis, Fabian J; Gabka, Christian; Sotlar, Karl; Scheel, Christina H
2015-09-15
We present an organoid regeneration assay in which freshly isolated human mammary epithelial cells are cultured in adherent or floating collagen gels, corresponding to a rigid or compliant matrix environment. In both conditions, luminal progenitors form spheres, whereas basal cells generate branched ductal structures. In compliant but not rigid collagen gels, branching ducts form alveoli at their tips, express basal and luminal markers at correct positions, and display contractility, which is required for alveologenesis. Thereby, branched structures generated in compliant collagen gels resemble terminal ductal-lobular units (TDLUs), the functional units of the mammary gland. Using the membrane metallo-endopeptidase CD10 as a surface marker enriches for TDLU formation and reveals the presence of stromal cells within the CD49f(hi)/EpCAM(-) population. In summary, we describe a defined in vitro assay system to quantify cells with regenerative potential and systematically investigate their interaction with the physical environment at distinct steps of morphogenesis. © 2015. Published by The Company of Biologists Ltd.
Koopmans-Compliant Spectral Functionals for Extended Systems
NASA Astrophysics Data System (ADS)
Nguyen, Ngoc Linh; Colonna, Nicola; Ferretti, Andrea; Marzari, Nicola
2018-04-01
Koopmans-compliant functionals have been shown to provide accurate spectral properties for molecular systems; this accuracy is driven by the generalized linearization condition imposed on each charged excitation, i.e., on changing the occupation of any orbital in the system, while accounting for screening and relaxation from all other electrons. In this work, we discuss the theoretical formulation and the practical implementation of this formalism to the case of extended systems, where a third condition, the localization of Koopmans's orbitals, proves crucial to reach seamlessly the thermodynamic limit. We illustrate the formalism by first studying one-dimensional molecular systems of increasing length. Then, we consider the band gaps of 30 paradigmatic solid-state test cases, for which accurate experimental and computational results are available. The results are found to be comparable with the state of the art in many-body perturbation theory, notably using just a functional formulation for spectral properties and the generalized-gradient approximation for the exchange and correlation functional.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, Max; Greenblatt, Jeffrey; Donovan, Sally
2014-06-01
This study provides an updated analysis of long-term energy system scenarios for California consistent with the State meeting its 2050 climate goal, including detailed analysis and assessment of electricity system build-out, operation, and costs across the Western Electricity Coordinating Council (WECC) region. Four key elements are found to be critical for the State to achieve its 2050 goal of 80 percent greenhouse (GHG) reductions from the 1990 level: aggressive energy efficiency; clean electricity; widespread electrification of passenger vehicles, building heating, and industry heating; and large-scale production of low-carbon footprint biofuels to largely replace petroleum-based liquid fuels. The approach taken heremore » is that technically achievable energy efficiency measures are assumed to be achieved by 2050 and aggregated with the other key elements mentioned above to estimate resultant emissions in 2050. The energy and non-energy sectors are each assumed to have the objective of meeting an 80 percent reduction from their respective 1990 GHG levels for the purposes of analysis. A different partitioning of energy and non-energy sector GHG greenhouse reductions is allowed if emission reductions in one sector are more economic or technically achievable than in the other. Similarly, within the energy or non-energy sectors, greater or less than 80 percent reduction from 1990 is allowed for sub-sectors within the energy or non-energy sectors as long as the overall target is achieved. Overall emissions for the key economy-wide scenarios are considered in this report. All scenarios are compliant or nearly compliant with the 2050 goal. This finding suggests that multiple technical pathways exist to achieve the target with aggressive policy support and continued technology development of largely existing technologies.« less
EPA Administrative Order on Consent (AOC) with ERP Compliant Coke, LLC
This Administrative Order on Consent with ERP Compliant Coke was effective August 2016. The Walter Coke facility located in North Birmingham was purchased by ERP Compliant Coke, LLC in February 2016 out of bankruptcy proceedings.
Compliant flooring to prevent fall-related injuries: a scoping review protocol.
Lachance, Chantelle C; Jurkowski, Michal P; Dymarz, Ania C; Mackey, Dawn C
2016-08-16
Fall-related injuries can have serious consequences for older adults, including increased risk of dependence in daily activities and mortality. Compliant flooring is a passive intervention that may reduce the incidence and severity of fall-related injuries in healthcare settings, including acute and long-term care, but few sites have implemented compliant flooring, in part because synthesised evidence about key performance aspects has not been available. We will conduct a scoping review to address the question: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries? We will conduct a comprehensive and systematic literature search of academic databases (AgeLine, CINAHL, EBM Reviews, MEDLINE (Ovid), SportDiscus and Web of Science) and grey literature (clinical trial registries, theses/dissertations, abstracts/conference proceedings and relevant websites). 2 team members will independently screen records (first titles and abstracts, then full text) and extract data from included records. Numerical and narrative analyses will be presented by theme (biomechanical efficacy, clinical effectiveness, cost-effectiveness, workplace safety). This scoping review responds to the information needs of healthcare decision-makers tasked with preventing fall-related injuries. This review will summarise evidence about compliant flooring as a potential intervention for preventing fall-related injuries in older adults and identify gaps in evidence and new avenues for research. Results will be especially useful in long-term care, but also applicable in acute care, assisted living and home care. We will disseminate the review's findings via open-access publications, conference presentations, a webinar, a Stakeholder Symposium and a Knowledge-to-Action Report. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Compliant flooring to prevent fall-related injuries: a scoping review protocol
Lachance, Chantelle C; Jurkowski, Michal P; Dymarz, Ania C; Mackey, Dawn C
2016-01-01
Introduction Fall-related injuries can have serious consequences for older adults, including increased risk of dependence in daily activities and mortality. Compliant flooring is a passive intervention that may reduce the incidence and severity of fall-related injuries in healthcare settings, including acute and long-term care, but few sites have implemented compliant flooring, in part because synthesised evidence about key performance aspects has not been available. Methods and analysis We will conduct a scoping review to address the question: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries? We will conduct a comprehensive and systematic literature search of academic databases (AgeLine, CINAHL, EBM Reviews, MEDLINE (Ovid), SportDiscus and Web of Science) and grey literature (clinical trial registries, theses/dissertations, abstracts/conference proceedings and relevant websites). 2 team members will independently screen records (first titles and abstracts, then full text) and extract data from included records. Numerical and narrative analyses will be presented by theme (biomechanical efficacy, clinical effectiveness, cost-effectiveness, workplace safety). Ethics and dissemination This scoping review responds to the information needs of healthcare decision-makers tasked with preventing fall-related injuries. This review will summarise evidence about compliant flooring as a potential intervention for preventing fall-related injuries in older adults and identify gaps in evidence and new avenues for research. Results will be especially useful in long-term care, but also applicable in acute care, assisted living and home care. We will disseminate the review's findings via open-access publications, conference presentations, a webinar, a Stakeholder Symposium and a Knowledge-to-Action Report. PMID:27531731
Safety and fitness electronic records system (SAFER) : draft master test plan
DOT National Transportation Integrated Search
1995-12-31
The purpose of this plan is to establish a formal set of guidelines and activities to be : adhered to and performed by JHU/APL and the developer to ensure that the SAFER System has been tested successfully and is fully compliant with the SAFER System...
Severe rhabdomyolysis and acute renal failure in an adolescent with hypothyroidism.
Comak, Elif; Koyun, Mustafa; Kiliçarslan-Akkaya, Bahar; Bircan, Iffet; Akman, Sema
2011-01-01
Hypothyroidism has been reported rarely as the cause of rhabdomyolysis in adults and children. We present here a non-compliant adolescent with a diagnosis of hypothyroidism who developed rhabdomyolysis and acute renal failure with no additional predisposing factor. A 13-year-old girl with a previous history of hypothyroidism due to thyroid hypoplasia presented with generalized myalgia, malaise, vomiting, and oliguria lasting for three days. Neurological examination revealed bilateral marked weakness and tenderness of muscles of both lower and upper extremities. Urine had bloody appearance and urine analysis showed blood reaction with dipstick test, but there were no erythrocytes on microscopic examination. Serum creatine phosphokinase and myoglobin levels were elevated. Thyroid stimulating hormone (TSH) levels were high, and free thyroxine (T4) and triiodothyronine (T3) levels were low, compatible with uncontrolled hypothyroidism. Renal function tests showed acute renal failure. Other causes of rhabdomyolysis such as muscular trauma, drugs, toxins, infections, vigorous exercise, and electrolyte abnormalities were excluded. Hemodialysis was administered for 24 sessions. After L-thyroxine therapy, thyroid function tests normalized, muscle strength improved, serum muscle enzyme levels returned to normal levels, and renal function tests recovered. One must be aware that rhabdomyolysis may develop in a non-compliant patient with hypothyroidism.
Surviving an Information Systems Conversion.
ERIC Educational Resources Information Center
Neel, Don
1999-01-01
Prompted by the "millennium bug," many school districts are in the process of replacing non-Y2K-compliant information systems. Planners should establish a committee to develop performance criteria and select the winning proposal, estimate time requirements, and schedule retraining during low-activity periods. (MLH)
On the theory of compliant wall drag reduction in turbulent boundary layers
NASA Technical Reports Server (NTRS)
Ash, R. L.
1974-01-01
A theoretical model has been developed which can explain how the motion of a compliant wall reduces turbulent skin friction drag. Available experimental evidence at low speeds has been used to infer that a compliant surface selectively removes energy from the upper frequency range of the energy containing eddies and through resulting surface motions can produce locally negative Reynolds stresses at the wall. The theory establishes a preliminary amplitude and frequency criterion as the basis for designing effective drag reducing compliant surfaces.
Compliant Interfacial Layers in Thermoelectric Devices
NASA Technical Reports Server (NTRS)
Firdosy, Samad A. (Inventor); Li, Billy Chun-Yip (Inventor); Ravi, Vilupanur A. (Inventor); Fleurial, Jean-Pierre (Inventor); Caillat, Thierry (Inventor); Anjunyan, Harut (Inventor)
2017-01-01
A thermoelectric power generation device is disclosed using one or more mechanically compliant and thermally and electrically conductive layers at the thermoelectric material interfaces to accommodate high temperature differentials and stresses induced thereby. The compliant material may be metal foam or metal graphite composite (e.g. using nickel) and is particularly beneficial in high temperature thermoelectric generators employing Zintl thermoelectric materials. The compliant material may be disposed between the thermoelectric segments of the device or between a thermoelectric segment and the hot or cold side interconnect of the device.
NASA Technical Reports Server (NTRS)
Shalkhauser, Mary Jo W.
2017-01-01
The Space Telecommunications Radio System (STRS) provides a common, consistent framework for software defined radios (SDRs) to abstract the application software from the radio platform hardware. The STRS standard aims to reduce the cost and risk of using complex, configurable and reprogrammable radio systems across NASA missions. To promote the use of the STRS architecture for future NASA advanced exploration missions, NASA Glenn Research Center (GRC) developed an STRS compliant SDR on a radio platform used by the Advance Exploration System program at the Johnson Space Center (JSC) in their Integrated Power, Avionics, and Software (iPAS) laboratory. At the conclusion of the development, the software and hardware description language (HDL) code was delivered to JSC for their use in their iPAS test bed to get hands-on experience with the STRS standard, and for development of their own STRS Waveforms on the now STRS compliant platform.The iPAS STRS Radio was implemented on the Reconfigurable, Intelligently-Adaptive Communication System (RIACS) platform, currently being used for radio development at JSC. The platform consists of a Xilinx ML605 Virtex-6 FPGA board, an Analog Devices FMCOMMS1-EBZ RF transceiver board, and an Embedded PC (Axiomtek eBox 620-110-FL) running the Ubuntu 12.4 operating system. Figure 1 shows the RIACS platform hardware. The result of this development is a very low cost STRS compliant platform that can be used for waveform developments for multiple applications.The purpose of this document is to describe the design of the HDL code for the FPGA portion of the iPAS STRS Radio particularly the design of the FPGA wrapper and the test waveform.
Summary of compliant and multi-arm control at NASA. Langley Research Center
NASA Technical Reports Server (NTRS)
Harrison, Fenton W.
1992-01-01
The topics are presented in viewgraph form and include the: single arm system, single arm axis system, single arm control systems, single arm hand controller axis system, single arm position axis system, single arm vision axis system, single arm force axis system, multi-arm system, multi-arm axis system, and the dual arm hand control axis system with control signals.
Bistable Mechanisms for Space Applications
Zirbel, Shannon A.; Tolman, Kyler A.; Trease, Brian P.
2016-01-01
Compliant bistable mechanisms are monolithic devices with two stable equilibrium positions separated by an unstable equilibrium position. They show promise in space applications as nonexplosive release mechanisms in deployment systems, thereby eliminating friction and improving the reliability and precision of those mechanical devices. This paper presents both analytical and numerical models that are used to predict bistable behavior and can be used to create bistable mechanisms in materials not previously feasible for compliant mechanisms. Materials compatible with space applications are evaluated for use as bistable mechanisms and prototypes are fabricated in three different materials. Pin-puller and cutter release mechanisms are proposed as potential space applications. PMID:28030588
Raul, P R; Dwivedula, R V; Pagilla, P R
2016-07-01
The problem of controlling the load speed of a mechanical transmission system consisting of a belt-pulley and gear-pair is considered. The system is modeled as two inertia (motor and load) connected by a compliant transmission. If the transmission is assumed to be rigid, then using either the motor or load speed feedback provides the same result. However, with transmission compliance, due to belts or long shafts, the stability characteristics and performance of the closed-loop system are quite different when either motor or load speed feedback is employed. We investigate motor and load speed feedback schemes by utilizing the singular perturbation method. We propose and discuss a control scheme that utilizes both motor and load speed feedback, and design an adaptive feedforward action to reject load torque disturbances. The control algorithms are implemented on an experimental platform that is typically used in roll-to-roll manufacturing and results are shown and discussed. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
The Cardiovascular Physiology of Sports and Exercise.
Opondo, Mildred A; Sarma, Satyam; Levine, Benjamin D
2015-07-01
Athletes represent the extremes of human performance. Many of their remarkable abilities stem from a cardiovascular system that has adapted to meet the metabolic needs of exercising muscle. A large and compliant heart is a hallmark feature of athletes who engage in highly aerobic events. Despite high fitness levels, athletes may present with symptoms that limit performance. Understanding and dissecting these limitations requires a strong background in sports science and the factors that determine sports capabilities. This article reviews the basic principles of exercise physiology, cardiovascular adaptations unique to the "athlete's heart," and the utility of exercise testing in athletes. Copyright © 2015 Elsevier Inc. All rights reserved.
Landscaping of highway medians and roadway safety at unsignalized intersections.
Chen, Hongyun; Fabregas, Aldo; Lin, Pei-Sung
2016-05-01
Well-planted and maintained landscaping can help reduce driving stress, provide better visual quality, and decrease over speeding, thus improving roadway safety. Florida Department of Transportation (FDOT) Standard Index (SI-546) is one of the more demanding standards in the U.S. for landscaping design criteria at highway medians near intersections. The purposes of this study were to (1) empirically evaluate the safety results of SI-546 at unsignalized intersections and (2) quantify the impacts of geometrics, traffic, and landscaping design features on total crashes and injury plus fatal crashes. The studied unsignalized intersections were divided into (1) those without median trees near intersections, (2) those with median trees near intersections that were compliant with SI-546, and (3) those with median trees near intersections that were non-compliant with SI-546. A total of 72 intersections were selected, for which five-year crash data from 2006-2010 were collected. The sites that were compliant with SI-546 showed the best safety performance in terms of the lowest crash counts and crash rates. Four crash predictive models-two for total crashes and two for injury crashes-were developed. The results indicated that improperly planted and maintained median trees near highway intersections can increase the total number of crashes and injury plus fatal crashes at a 90% confidence level; no significant difference could be found in crash rates between sites that were compliant with SI-546 and sites without trees. All other conditions remaining the same, an intersection with trees that was not compliant with SI-546 had 63% more crashes and almost doubled injury plus fatal crashes than those at intersections without trees. The study indicates that appropriate landscaping in highway medians near intersections can be an engineering technology that not only improves roadway environmental quality but also maintains intersection safety. Copyright © 2016. Published by Elsevier Ltd.
41 CFR 102-33.195 - Do we need an automated system to account for aircraft costs?
Code of Federal Regulations, 2010 CFR
2010-07-01
... FAIRS-compliant system are described in the “Common Aviation Management Information Standard” (C-AMIS... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Do we need an automated... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL...
Passive control of a biventricular assist device with compliant inflow cannulae.
Gregory, Shaun David; Pearcy, Mark John; Timms, Daniel
2012-08-01
Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Scalable sensor management for automated fusion and tactical reconnaissance
NASA Astrophysics Data System (ADS)
Walls, Thomas J.; Wilson, Michael L.; Partridge, Darin C.; Haws, Jonathan R.; Jensen, Mark D.; Johnson, Troy R.; Petersen, Brad D.; Sullivan, Stephanie W.
2013-05-01
The capabilities of tactical intelligence, surveillance, and reconnaissance (ISR) payloads are expanding from single sensor imagers to integrated systems-of-systems architectures. Increasingly, these systems-of-systems include multiple sensing modalities that can act as force multipliers for the intelligence analyst. Currently, the separate sensing modalities operate largely independent of one another, providing a selection of operating modes but not an integrated intelligence product. We describe here a Sensor Management System (SMS) designed to provide a small, compact processing unit capable of managing multiple collaborative sensor systems on-board an aircraft. Its purpose is to increase sensor cooperation and collaboration to achieve intelligent data collection and exploitation. The SMS architecture is designed to be largely sensor and data agnostic and provide flexible networked access for both data providers and data consumers. It supports pre-planned and ad-hoc missions, with provisions for on-demand tasking and updates from users connected via data links. Management of sensors and user agents takes place over standard network protocols such that any number and combination of sensors and user agents, either on the local network or connected via data link, can register with the SMS at any time during the mission. The SMS provides control over sensor data collection to handle logging and routing of data products to subscribing user agents. It also supports the addition of algorithmic data processing agents for feature/target extraction and provides for subsequent cueing from one sensor to another. The SMS architecture was designed to scale from a small UAV carrying a limited number of payloads to an aircraft carrying a large number of payloads. The SMS system is STANAG 4575 compliant as a removable memory module (RMM) and can act as a vehicle specific module (VSM) to provide STANAG 4586 compliance (level-3 interoperability) to a non-compliant sensor system. The SMS architecture will be described and results from several flight tests and simulations will be shown.
. REAL ID LANL Impacts and Solutions The federal government has determined New Mexico is non-compliant Identification Cards whom will also become Non-Compliant. Access through LANL Vehicle Access Portals unaffected alternate ID if they are coming from "non-compliant" REAL-ID states LANS and the Field Office have
Code of Federal Regulations, 2012 CFR
2012-10-01
... Compliant Microcomputers, Including Personal Computers, Monitors and Printers. 1552.239-103 Section 1552.239... Star Compliant Microcomputers, Including Personal Computers, Monitors and Printers. As prescribed in... Personal Computers, Monitors, and Printers (APR 1996) (a) The Contractor shall provide computer products...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Compliant Microcomputers, Including Personal Computers, Monitors and Printers. 1552.239-103 Section 1552.239... Star Compliant Microcomputers, Including Personal Computers, Monitors and Printers. As prescribed in... Personal Computers, Monitors, and Printers (APR 1996) (a) The Contractor shall provide computer products...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Compliant Microcomputers, Including Personal Computers, Monitors and Printers. 1552.239-103 Section 1552.239... Star Compliant Microcomputers, Including Personal Computers, Monitors and Printers. As prescribed in... Personal Computers, Monitors, and Printers (APR 1996) (a) The Contractor shall provide computer products...
Performance of a non-tapered 3D morphing wing with integrated compliant ribs
NASA Astrophysics Data System (ADS)
Previtali, F.; Ermanni, P.
2012-05-01
Morphing wings have a high potential for improving the performance and reducing the fuel consumption of modern aircraft. Thanks to its simplicity, the compliant belt-rib concept is regarded by the authors as a promising solution. Using the compliant rib designed by Hasse and Campanile as a starting point, a compliant morphing wing made of composite materials is designed. Innovative methods for optimal placing of the actuation and for the quantification of the morphing are used. The performance of the compliant morphing wing in terms of three-dimensional (3D) structural behaviour and aerodynamic properties, both two- and three-dimensional, is presented and discussed. The fundamental importance of considering 3D coupling effects in the determination of the performance of morphing aerofoils is shown.
Section 508 Standards Resources
Learn which software applications, operating systems, web-based applications, and other electronic and information technology (EIT) products are covered by Section 508 of the Rehabilitation Act; and resources for making sure your EIT products are compliant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clements, Samuel L.; Edgar, Thomas W.; Manz, David O.
The purpose of this workshop was to identify and discuss concerns with the use and adoption of IEC 62351 security standard for IEC 61850 compliant control system products. The industry participants discussed performance, interoperability, adoption, challenges, business cases, and future issues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srinivasan, M.G.; Kot, C.A.; Mojtahed, M.
The paper describes the analytical modeling, calculations, and results of the posttest nonlinear simulation of high-level seismic testing of the VKL piping system at the HDR Test Facility in Germany. One of the objectives of the tests was to evaluate analytical methods for calculating the nonlinear response of realistic piping systems subjected to high-level seismic excitation that would induce significant plastic deformation. Two out of the six different pipe-support configurations, (ranging from a stiff system with struts and snubbers to a very flexible system with practically no seismic supports), subjected to simulated earthquakes, were tested at very high levels. Themore » posttest nonlinear calculations cover the KWU configuration, a reasonably compliant system with only rigid struts. Responses for 800% safe-shutdown-earthquake loading were calculated using the NONPIPE code. The responses calculated with NONPIPE were found generally to have the same time trends as the measurements but contained under-, over-, and correct estimates of peak values, almost in equal proportions. The only exceptions were the peak strut forces, which were underestimated as a group. The scatter in the peak value estimate of displacements and strut forces was smaller than that for the strains. The possible reasons for the differences and the effort on further analysis are discussed.« less
Raschke, Silvia U; Orendurff, Michael S; Mattie, Johanne L; Kenyon, David E A; Jones, O Yvette; Moe, David; Winder, Lorne; Wong, Angie S; Moreno-Hernández, Ana; Highsmith, M Jason; J Sanderson, David; Kobayashi, Toshiki
2015-01-02
Providing appropriate prosthetic feet to those with limb loss is a complex and subjective process influenced by professional judgment and payer guidelines. This study used a small load cell (Europa™) at the base of the socket to measure the sagittal moments during walking with three objective categories of prosthetic feet in eleven individuals with transtibial limb loss with MFCL K2, K3 and K4 functional levels. Forefoot stiffness and hysteresis characteristics defined the three foot categories: Stiff, Intermediate, and Compliant. Prosthetic feet were randomly assigned and blinded from participants and investigators. After laboratory testing, participants completed one week community wear tests followed by a modified prosthetics evaluation questionnaire to determine if a specific category of prosthetic feet was preferred. The Compliant category of prosthetic feet was preferred by the participants (P=0.025) over the Stiff and Intermediate prosthetic feet, and the Compliant and Intermediate feet had 15% lower maximum sagittal moments during walking in the laboratory (P=0.0011) compared to the Stiff feet. The activity level of the participants did not change significantly with any of the wear tests in the community, suggesting that each foot was evaluated over a similar number of steps, but did not inherently increase activity. This is the first randomized double blind study in which prosthetic users have expressed a preference for a specific biomechanical characteristic of prosthetic feet: those with lower peak sagittal moments were preferred, and specifically preferred on slopes, stairs, uneven terrain, and during turns and maneuvering during real world use. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Han, Fucai; Banerjee, Anirban; Shen, Liang; Krishna, Lingaraj
2015-01-01
Background: Successful return to sport is an important outcome measure after anterior cruciate ligament (ACL) reconstruction and a reason for patients’ decisions to elect surgery. Rehabilitation programs supervised by physical therapists are routinely prescribed after ACL reconstruction surgery. However, the added advantage of supervised physical therapy after ACL reconstruction is still debatable. Hypothesis: Attending more supervised physical therapy sessions after arthroscopic ACL reconstruction in recreational athletes increases their chance of successful return to sport. Study Design: Cohort study; Level of evidence, 3. Methods: The authors analyzed 93 recreational athletes who underwent arthroscopic ACL reconstruction. After arthroscopic single-bundle ACL reconstruction, patients were advised to attend 20 supervised physical therapy sessions. Patients’ demographics, surgical details, and outcome measures (Knee injury and Osteoarthritis Outcome Score [KOOS], Lysholm scale, and Short Form–36 Health Survey [SF-36]) were recorded presurgery and at 1-year follow-up. Ability to return to sports was documented through patients’ self-report. The attendance at physical therapy by each patient was obtained by examining database records and assessed as fully compliant (>15 sessions), moderately compliant (6-15 sessions), or noncompliant (<6 sessions). Results: Patients in the fully compliant group had significantly greater odds (odds ratio [OR], 18.5; 95% CI, 1.9-184.5; P = .013) of a successful return to sport as compared with the noncompliant group. Patients in the moderately compliant group also had greater odds of returning to sport as compared with the noncompliant group (OR, 4.2; 95% CI, 1.0-16.6; P = .043). Patients in the fully compliant group had significantly greater scores on the Lysholm (P < .001), KOOS Sports and Recreation subscale (P = .021), KOOS Symptoms subscale (P = .040), and SF-36 physical component summary (PCS) (P = .012) as compared with the noncompliant group. Moderately compliant patients had significantly greater scores on the Lysholm (P = .004), KOOS Sports and Recreation (P = .026), KOOS Symptoms (P = .041), KOOS Quality of Life (P = .022), and SF-36 PCS (P = .004) as compared with noncompliant patients. Conclusion: In recreational athletes, moderate to full compliance with a supervised physical therapy program predicts improved knee function and a greater chance of returning to sport 1 year after ACL reconstruction. PMID:26740958
Drinking Water Quality and the Geospatial Distribution of Notified Gastro-Intestinal Infections
GRILC, Eva; GALE, Ivanka; VERŠIČ, Aleš; ŽAGAR, Tina; SOČAN, Maja
2015-01-01
Introduction Even brief episodes of fecal contamination of drinking water can lead directly to illness in the consumers. In water-borne outbreaks, the connection between poor microbial water quality and disease can be quickly identified. The impact of non-compliant drinking water samples due to E. coli taken for regular monitoring on the incidence of notified acute gastrointestinal infections has not yet been studied. Methods The objective of this study was to analyse the geographical distribution of notified acute gastrointestinal infections (AGI) in Slovenia in 2010, with hotspot identification. The second aim of the study was to correlate the fecal contamination of water supply system on the settlement level with the distribution of notified AGI cases. Spatial analysis using geo-information technology and other methods were used. Results Hot spots with the highest proportion of notified AGI cases were mainly identified in areas with small supply zones. The risk for getting AGI was drinking water contaminated with E. coli from supply zones with 50–1000 users: RR was 1.25 and significantly greater than one (p-value less than 0.001). Conclusion This study showed the correlation between the frequency of notified AGI cases and non-compliant results in drinking water monitoring. PMID:27646727
Training Children with Autism Spectrum Disorders to Be Compliant with an Oral Assessment
ERIC Educational Resources Information Center
Cuvo, Anthony J.; Godard, Anna; Huckfeldt, Rachel; DeMattei, Ronda
2010-01-01
Little research has been conducted on teaching children with autism spectrum disorders to be compliant with dental procedures. This study evaluated a behavioral package to train children with autism spectrum disorders to be compliant with an 8 component oral assessment. After a dental hygienist performed an assessment pretest, noncompliance on…
Becker, B S; Bolton, J D
1997-12-01
Artificial hip joints have an average lifetime of 10 years due to aseptic loosening of the femoral stem attributed to polymeric wear debris; however, there is a steadily increasing demand from younger osteoarthritis patients aged between 15 and 40 year for a longer lasting joint of 25 years or more. Compliant layers incorporated into the acetabular cup generate elastohydrodynamic lubrication conditions between the bearing surfaces, reduce joint friction coefficients and wear debris production and could increase the average life of total hip replacements, and other human load-bearing joint replacements, i.e. total knee replacements. Poor adhesion between a fully dense substrate and the compliant layer has so far prevented any further exploitation. This work investigated the possibility of producing porous metallic, functionally gradient type acetabular cups using powder metallurgy techniques - where a porous surface was supported by a denser core - into which the compliant layers could be incorporated. The corrosion behaviour and mechanical properties of three biomedically approved alloys containing two levels of total porosity (>30% and <10%) were established, resulting in Ti-6Al-4V being identified as the most promising biocompatible functionally graded material, not only for this application but for other hard-tissue implants.
Ekselius, L; Bengtsson, F; von Knorring, L
2000-09-01
Inadequate compliance of drug intake is an important cause of ineffective pharmacotherapy and has been associated with therapeutic failure. We hypothesized that sensation seeking personality traits would affect compliance with long-term antidepressant medication. Three hundred and eight depressed patients participating in a randomized double-blind study of sertraline and citalopram were included. Personality traits were assessed using the Karolinska Scales of Personality. Compliance to medication was determined in two ways, by means of tablet counting and by measurement concentration of drug in serum. Tablet non-compliance was defined as less than 80% or more than 100% intake of the prescribed drug during weeks 20-24. Serum drug non-compliance was defined as undetectable amounts of either drug and main metabolite in the serum samples at week 24. Two virtually not overlapping groups of non-compliant patients were identified, where those regarded as non-compliant due to the interpretation of the serum drug levels were in majority. The group of serum drug non-compliant patients were recognized by significantly higher scores on the Monotony Avoidance scale and the Impulsive Sensation Seeking Psychopathy factor. The need for better methods than tablet counting and patient questioning to ascertain compliance is emphasized.
Power bases and attribution in three cultures.
Alanazi, Falah M; Rodrigues, Aroldo
2003-06-01
The authors used a Saudi context to verify the cross-cultural generality of findings (A. Rodrigues & K. L. Lloyd, 1998) reported for U.S. and Brazilian samples in which compliant behavior caused by reward, informational, and referent influences was perceived as more controllable and more internal than compliant behavior resulting from legitimate, expert, and coercive influences. This differential attribution led, in turn, to different affective and behavioral responses. In the present study, cognitive and affective reactions of Saudi students were measured with regard to compliant behavior (leading to a good outcome or a bad outcome) caused by each of the 6 bases of power described by B. H. Raven (1965). As expected, power bases had significant effects. However, when the outcome of the compliant behavior was bad, compliant behavior caused by a coercive influence led to the perception of more internality and controllability. Also--and not found in previous studies--the perception of less internality and controllability of compliant behavior was caused by an informational influence. Findings are discussed in the light of related research and Saudi cultural characteristics.
Load Capacity Estimation of Foil Air Journal Bearings for Oil-Free Turbomachinery Applications
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Valco, Mark J.
2000-01-01
This paper introduces a simple "Rule of Thumb" (ROT) method to estimate the load capacity of foil air journal bearings, which are self-acting compliant-surface hydrodynamic bearings being considered for Oil-Free turbo-machinery applications such as gas turbine engines. The ROT is based on first principles and data available in the literature and it relates bearing load capacity to the bearing size and speed through an empirically based load capacity coefficient, D. It is shown that load capacity is a linear function of bearing surface velocity and bearing projected area. Furthermore, it was found that the load capacity coefficient, D, is related to the design features of the bearing compliant members and operating conditions (speed and ambient temperature). Early bearing designs with basic or "first generation" compliant support elements have relatively low load capacity. More advanced bearings, in which the compliance of the support structure is tailored, have load capacities up to five times those of simpler designs. The ROT enables simplified load capacity estimation for foil air journal bearings and can guide development of new Oil-Free turbomachinery systems.
Adaptivity in ProPer: An Adaptive SCORM Compliant LMS
ERIC Educational Resources Information Center
Kazanidis, Ioannis; Satratzemi, Maya
2009-01-01
Adaptive Educational Hypermedia Systems provide personalized educational content to learners. However most of them do not support the functionality of Learning Management Systems (LMS) and the reusability of their courses is hard work. On the other hand some LMS support SCORM specifications but do not provide adaptive features. This article…
School Accountability Systems and the Every Student Succeeds Act. Re:VISION
ERIC Educational Resources Information Center
Martin, Mike
2016-01-01
The "Every Student Succeeds Act" (ESSA) replaced the "No Child Left Behind Act of 2001" (NCLB) in December 2015, substantially changing the federal role in education and how schools across the country will be held accountable. For state policymakers, designing new ESSA-compliant accountability systems is a significant…
7 CFR 1753.6 - Standards, specifications, and general requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE TELECOMMUNICATIONS SYSTEM CONSTRUCTION POLICIES AND PROCEDURES... subject to the “Buy American” provision (7 U.S.C. 901 et seq. as amended in 1938). (e) All software, software systems, and firmware financed with loan funds must be year 2000 compliant, as defined in 7 CFR...
40 CFR 63.343 - Compliance provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operators of affected sources. (1) Composite mesh-pad systems. (i) During the initial performance test, the... with the emission limitations in § 63.342 through the use of a composite mesh-pad system shall... one performance test and accept ±2 inches of water column from this value as the compliant range. (ii...
40 CFR 63.343 - Compliance provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operators of affected sources. (1) Composite mesh-pad systems. (i) During the initial performance test, the... with the emission limitations in § 63.342 through the use of a composite mesh-pad system shall... one performance test and accept ±2 inches of water column from this value as the compliant range. (ii...
40 CFR 63.343 - Compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operators of affected sources. (1) Composite mesh-pad systems. (i) During the initial performance test, the... with the emission limitations in § 63.342 through the use of a composite mesh-pad system shall... one performance test and accept ±2 inches of water column from this value as the compliant range. (ii...
Mathematical circulatory system model
NASA Technical Reports Server (NTRS)
Lakin, William D. (Inventor); Stevens, Scott A. (Inventor)
2010-01-01
A system and method of modeling a circulatory system including a regulatory mechanism parameter. In one embodiment, a regulatory mechanism parameter in a lumped parameter model is represented as a logistic function. In another embodiment, the circulatory system model includes a compliant vessel, the model having a parameter representing a change in pressure due to contraction of smooth muscles of a wall of the vessel.
Four-Wheel Vehicle Suspension System
NASA Technical Reports Server (NTRS)
Bickler, Donald B.
1990-01-01
Four-wheel suspension system uses simple system of levers with no compliant components to provide three-point suspension of chassis of vehicle while maintaining four-point contact with uneven terrain. Provides stability against tipping of four-point rectangular base, without rocking contact to which rigid four-wheel frame susceptible. Similar to six-wheel suspension system described in "Articulated Suspension Without Springs" (NPO-17354).
Scientific & Intelligence Exascale Visualization Analysis System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Money, James H.
SIEVAS provides an immersive visualization framework for connecting multiple systems in real time for data science. SIEVAS provides the ability to connect multiple COTS and GOTS products in a seamless fashion for data fusion, data analysis, and viewing. It provides this capability by using a combination of micro services, real time messaging, and web service compliant back-end system.
2013-09-30
fire sprinkler system during the initial construction of the RSOI facilities. The construction contract to build the RSOI...International Building Code. Compliant manual and automatic fire alarm and notification systems , portable fire extinguishers, fire sprinkler systems ...automatic fire sprinkler system that was not operational, a fire department connection that was obstructed, and a fire detection system
Environmentally Compliant Coating Remover Evaluation
2012-08-30
22 9 Total of 491 products evaluated 7 Background • Many DoD depainting operations currently use environmentally compliant peroxide -assisted... benzyl alcohol strippers • These strippers have acceptable coating removal rates with minimal physical damage to metallic substrates • However, several...Coatings • Environmentally compliant benzyl alcohol product • Passed corrosion testing conducted by SMI in 2011 11 Laboratory Testing Scope
Krisciunas, Gintas P.; McCulloch, Timothy M.; Lazarus, Cathy L.; Pauloski, Barbara R.; Meyer, Tanya K.; Graner, Darlene; Van Daele, Douglas J.; Silbergleit, Alice K.; Crujido, Lisa R.; Rybin, Denis; Doros, Gheorghe; Kotz, Tamar; Langmore, Susan E.
2016-01-01
Purpose A 5yr, 16 site, randomized controlled trial enrolled 170 HNC survivors into active (estim + swallow exercise) or control (sham estim + swallowing exercise) arms. Primary analyses showed that estim did not enhance swallowing exercises. This secondary analysis determined if/how patient compliance impacted outcomes. Methods A home program, performed 2×/day, 6d/wk, for 12wks included stretches and 60 swallows paired with real or sham estim. Regular clinic visits ensured proper exercise execution and detailed therapy checklists tracked patient compliance which was defined by mean number of sessions performed per week (0-12 times) over the 12wk intervention period. “Compliant” was defined as performing 10-12 sessions/wk. Outcomes were change in PAS, HNCI, PSS, OPSE, and hyoid excursion. ANCOVA analyses determined if outcomes differed between real/sham and compliant/noncompliant groups after 12wks of therapy. Results Of the 170 patients enrolled, 153 patients had compliance data. The mean number of sessions performed was 8.57/wk (median=10.25). Fifty four percent of patients (n=83) were considered “compliant”. After 12wks of therapy, compliant patients in the sham estim group realized significantly better PAS scores than compliant patients in the active estim group (p=0.0074). When pooling all patients together, there were no significant differences in outcomes between compliant and non-compliant patients. Conclusions The addition of estim to swallowing exercises resulted in worse swallowing outcomes than exercises alone, which was more pronounced in compliant patients. Since neither compliant nor non-compliant patients benefitted from swallowing exercises, the proper dose and/or efficacy of swallowing exercises must also be questioned in this patient population. PMID:27848021
Compliance with gastric cancer guidelines is associated with improved outcomes.
Worhunsky, David J; Ma, Yifei; Zak, Yulia; Poultsides, George A; Norton, Jeffrey A; Rhoads, Kim F; Visser, Brendan C
2015-03-01
Limited data are available on the implementation and effectiveness of NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) for Gastric Cancer. We sought to assess rates of compliance with NCCN Guidelines, specifically stage-specific therapy during the initial episode of care, and to determine its impact on outcomes. The California Cancer Registry was used to identify cases of gastric cancer from 2001 to 2006. Logistic regression and Cox proportional hazard models were used to predict guideline compliance and the adjusted hazard ratio for mortality. Patients with TNM staging or summary stage (SS) were also analyzed separately. Compliance with NCCN Guidelines occurred in just 45.5% of patients overall. Patients older than 55 years were less likely to receive guideline-compliant care, and compliance was associated with a median survival of 20 versus 7 months for noncompliant care (P<.001). Compliant care was also associated with a 55% decreased hazard of mortality (P<.001). Further analysis revealed that 50% of patients had complete TNM staging versus an SS, and TNM-staged patients were more likely to receive compliant care (odds ratio, 1.59; P<.001). TNM-staged patients receiving compliant care had a median survival of 25.3 months compared with 15.1 months for compliant SS patients. Compliance with NCCN Guidelines and stage-specific therapy at presentation for the treatment of patients with gastric cancer was poor, which was a significant finding given that compliant care was associated with a 55% reduction in the hazard of death. Additionally, patients with TNM-staged cancer were more likely to receive compliant care, perhaps a result of having received more intensive therapy. Combined with the improved survival among compliant TNM-staged patients, these differences have meaningful implications for health services research. Copyright © 2015 by the National Comprehensive Cancer Network.
Assessing the degradation of compliant electrodes for soft actuators.
Rosset, Samuel; de Saint-Aubin, Christine; Poulin, Alexandre; Shea, Herbert R
2017-10-01
We present an automated system to measure the degradation of compliant electrodes used in dielectric elastomer actuators (DEAs) over millions of cycles. Electrodes for DEAs generally experience biaxial linear strains of more than 10%. The decrease in electrode conductivity induced by this repeated fast mechanical deformation impacts the bandwidth of the actuator and its strain homogeneity. Changes in the electrode mechanical properties lead to reduced actuation strain. Rather than using an external actuator to periodically deform the electrodes, our measurement method consists of measuring the properties of an electrode in an expanding circle DEA. A programmable high voltage power supply drives the actuator with a square signal up to 1 kHz, periodically actuating the DEA, and thus stretching the electrodes. The DEA strain is monitored with a universal serial bus camera, while the resistance of the ground electrode is measured with a multimeter. The system can be used for any type of electrode. We validated the test setup by characterising a carbon black/silicone composite that we commonly use as compliant electrode. Although the composite is well-suited for tens of millions of cycles of actuation below 5%, we observe important degradation for higher deformations. When activated at a 20% radial strain, the electrodes suffer from important damage after a few thousand cycles, and an inhomogeneous actuation is observed, with the strain localised in a sub-region of the actuator only.
Assessing the degradation of compliant electrodes for soft actuators
NASA Astrophysics Data System (ADS)
Rosset, Samuel; de Saint-Aubin, Christine; Poulin, Alexandre; Shea, Herbert R.
2017-10-01
We present an automated system to measure the degradation of compliant electrodes used in dielectric elastomer actuators (DEAs) over millions of cycles. Electrodes for DEAs generally experience biaxial linear strains of more than 10%. The decrease in electrode conductivity induced by this repeated fast mechanical deformation impacts the bandwidth of the actuator and its strain homogeneity. Changes in the electrode mechanical properties lead to reduced actuation strain. Rather than using an external actuator to periodically deform the electrodes, our measurement method consists of measuring the properties of an electrode in an expanding circle DEA. A programmable high voltage power supply drives the actuator with a square signal up to 1 kHz, periodically actuating the DEA, and thus stretching the electrodes. The DEA strain is monitored with a universal serial bus camera, while the resistance of the ground electrode is measured with a multimeter. The system can be used for any type of electrode. We validated the test setup by characterising a carbon black/silicone composite that we commonly use as compliant electrode. Although the composite is well-suited for tens of millions of cycles of actuation below 5%, we observe important degradation for higher deformations. When activated at a 20% radial strain, the electrodes suffer from important damage after a few thousand cycles, and an inhomogeneous actuation is observed, with the strain localised in a sub-region of the actuator only.
Generalized constitutive equations for piezo-actuated compliant mechanism
NASA Astrophysics Data System (ADS)
Cao, Junyi; Ling, Mingxiang; Inman, Daniel J.; Lin, Jin
2016-09-01
This paper formulates analytical models to describe the static displacement and force interactions between generic serial-parallel compliant mechanisms and their loads by employing the matrix method. In keeping with the familiar piezoelectric constitutive equations, the generalized constitutive equations of compliant mechanism represent the input-output displacement and force relations in the form of a generalized Hooke’s law and as analytical functions of physical parameters. Also significantly, a new model of output displacement for compliant mechanism interacting with piezo-stacks and elastic loads is deduced based on the generalized constitutive equations. Some original findings differing from the well-known constitutive performance of piezo-stacks are also given. The feasibility of the proposed models is confirmed by finite element analysis and by experiments under various elastic loads. The analytical models can be an insightful tool for predicting and optimizing the performance of a wide class of compliant mechanisms that simultaneously consider the influence of loads and piezo-stacks.
Klimyuk, Victor; Pogue, Gregory; Herz, Stefan; Butler, John; Haydon, Hugh
2014-01-01
This review describes the adaptation of the plant virus-based transient expression system, magnICON(®) for the at-scale manufacturing of pharmaceutical proteins. The system utilizes so-called "deconstructed" viral vectors that rely on Agrobacterium-mediated systemic delivery into the plant cells for recombinant protein production. The system is also suitable for production of hetero-oligomeric proteins like immunoglobulins. By taking advantage of well established R&D tools for optimizing the expression of protein of interest using this system, product concepts can reach the manufacturing stage in highly competitive time periods. At the manufacturing stage, the system offers many remarkable features including rapid production cycles, high product yield, virtually unlimited scale-up potential, and flexibility for different manufacturing schemes. The magnICON system has been successfully adaptated to very different logistical manufacturing formats: (1) speedy production of multiple small batches of individualized pharmaceuticals proteins (e.g. antigens comprising individualized vaccines to treat NonHodgkin's Lymphoma patients) and (2) large-scale production of other pharmaceutical proteins such as therapeutic antibodies. General descriptions of the prototype GMP-compliant manufacturing processes and facilities for the product formats that are in preclinical and clinical testing are provided.
Flexural anchorage performance at diagonal crack locations.
DOT National Transportation Integrated Search
2010-12-01
Large numbers of reinforced concrete deck girder bridges that were constructed during the interstate system expansion of the 1950s have developed diagonal cracking in the stems. Though compliant with design codes when constructed, many of these bridg...
Stirling engines for hybrid electric vehicle applications
NASA Astrophysics Data System (ADS)
Ernst, William D.
Laboratory and vehicle chassis dynamometer test data based on natural gas fuel are presented for kinematic Stirling engine emissions levels over a range of air/fuel ratios and exhaust gas recirculation levels. It is concluded that the natural-gas-fired Stirling engine is capable of producing exhaust pipe emissions levels significantly below those of other engines. The projected emissions levels are found to be compliant with the 1995 California Air Resources Board Mobile Source Emission Standards for ultra-low-emissions vehicles.
Performance through Deformation and Instability
NASA Astrophysics Data System (ADS)
Bertoldi, Katia
2015-03-01
Materials capable of undergoing large deformations like elastomers and gels are ubiquitous in daily life and nature. An exciting field of engineering is emerging that uses these compliant materials to design active devices, such as actuators, adaptive optical systems and self-regulating fluidics. Compliant structures may significantly change their architecture in response to diverse stimuli. When excessive deformation is applied, they may eventually become unstable. Traditionally, mechanical instabilities have been viewed as an inconvenience, with research focusing on how to avoid them. Here, I will demonstrate that these instabilities can be exploited to design materials with novel, switchable functionalities. The abrupt changes introduced into the architecture of soft materials by instabilities will be used to change their shape in a sudden, but controlled manner. Possible and exciting applications include materials with unusual properties such negative Poisson's ratio, phononic crystals with tunable low-frequency acoustic band gaps and reversible encapsulation systems.
Pulsatile flow in a compliant stenosed asymmetric model
NASA Astrophysics Data System (ADS)
Usmani, Abdullah Y.; Muralidhar, K.
2016-12-01
Time-varying velocity field in an asymmetric constricted tube is experimentally studied using a two-dimensional particle image velocimetry system. The geometry resembles a vascular disease which is characterized by arterial narrowing due to plaque deposition. The present study compares the nature of flow patterns in rigid and compliant asymmetric constricted tubes for a range of dimensionless parameters appearing in a human artery. A blood analogue fluid is employed along with a pump that mimics cardioflow conditions. The peak Reynolds number range is Re 300-800, while the Womersley number range considered in experiments is Wo 6-8. These values are based on the peak velocity in a straight rigid tube connected to the model, over a pulsation frequency range of 1.2-2.4 Hz. The medial-plane velocity distribution is used to investigate the nature of flow patterns. Temporal distribution of stream traces and hemodynamic factors including WSS, TAWSS and OSI at important phases of the pulsation cycle are discussed. The flow patterns obtained from PIV are compared to a limited extent against numerical simulation. Results show that the region downstream of the constriction is characterized by a high-velocity jet at the throat, while a recirculation zone, attached to the wall, evolves in time. Compliant models reveal large flow disturbances upstream during the retrograde flow. Wall shear stress values are lower in a compliant model as compared to the rigid. Cross-plane flow structures normal to the main flow direction are visible at select phases of the cycle. Positive values of largest Lyapunov exponent are realized for wall movement and are indicative of chaotic motion transferred from the flow to the wall. These exponents increase with Reynolds number as well as compliance. Period doubling is observed in wall displacement of highly compliant models, indicating possible triggering of hemodynamic events in a real artery that may cause fissure in the plaque deposits.
Polat, Gökhan; Karademir, Gökhan; Akalan, Ekin; Aşık, Mehmet; Erdil, Mehmet
2017-03-20
The aim of this study was to prospectively evaluate the compliance of our patients with a touchdown weight bearing (without supporting any weight on the affected side by only touching the plantar aspect of the foot to the ground to maintain balance to protect the affected side from mechanical loading) postoperative rehabilitation protocol after treatment of talar osteochondral lesion (TOL). Fourteen patients, who had been treated with arthroscopic debridement and microfracture, were followed prospectively. The patients were evaluated for weight bearing compliance with using a stationary gait analysis and feedback system at the postoperative first day, first week, third week, and sixth week. The mean visual analog scale (VAS) scores of the patients at the preoperative, postoperative first day, first week, third week, and sixth weeks were 5.5, 5.9, 3.6, 0.9, and 0.4, respectively. The decrease in VAS scores were statistically significant (p < 0.0001). First postoperative day revealed a mean value of transmitted weight of 4.08% ±0.8 (one non-compliant patient). The mean value was 4.34% ±0.8 at the first postoperative week (two non-compliant patients), 6.95% ±2.3 at the third postoperative week (eight non-compliant patients), and 10.8% ±4.8 at the sixth postoperative week (11 non-compliant patients). In the analysis of data, we found a negative correlation between VAS scores and transmitted weight (Kendall's tau b = -0.445 and p = 0.0228). Although patients were able to learn and adjust to the touchdown weight bearing gait protocol during the early postoperative period, most patients became non-compliant when their pain was relieved. To prevent this situation of non-compliance, patients should be warned to obey the weight bearing restrictions, and patients should be called for a follow-up at the third postoperative week.
Van Assche, Kerlijn; Nebot Giralt, Ariadna; Caudron, Jean Michel; Schiavetti, Benedetta; Pouget, Corinne; Tsoumanis, Achilleas; Meessen, Bruno; Ravinetto, Raffaella
2018-01-01
The rapid globalisation of the pharmaceutical production and distribution has not been supported by harmonisation of regulatory systems worldwide. Thus, the supply systems in low-income and middle-income countries (LMICs) remain exposed to the risk of poor-quality medicines. To contribute to estimating this risk in the private sector in LMICs, we assessed the quality assurance system of a convenient sample of local private pharmaceutical distributors. This descriptive study uses secondary data derived from the audits conducted by the QUAMED group at 60 local private pharmaceutical distributors in 13 LMICs. We assessed the distributors' compliance with good distribution practices (GDP), general quality requirements (GQR) and cold chain management (CCM), based on an evaluation tool inspired by the WHO guidelines 'Model Quality Assurance System (MQAS) for procurement agencies'. Descriptive statistics describe the compliance for the whole sample, for distributors in sub-Saharan Africa (SSA) versus those in non-SSA, and for those in low-income countries (LICs) versus middle-income countries (MICs). Local private pharmaceutical distributors in our sample were non-compliant, very low-compliant or low-compliant for GQR (70%), GDP (60%) and CCM (41%). Only 7/60 showed good to full compliance for at least two criteria. Observed compliance varies by geographical region and by income group: maximum values are higher in non-SSA versus SSA and in MICs versus LICs, while minimum values are the same across different groups. The poor compliance with WHO quality standards observed in our sample indicates a concrete risk that patients in LMICs are exposed to poor-quality or degraded medicines. Significant investments are needed to strengthen the regulatory supervision, including on private pharmaceutical distributors. An adapted standardised evaluation tool inspired by the WHO MQAS would be helpful for self-evaluation, audit and inspection purposes.
Connections for solid oxide fuel cells
Collie, Jeffrey C.
1999-01-01
A connection for fuel cell assemblies is disclosed. The connection includes compliant members connected to individual fuel cells and a rigid member connected to the compliant members. Adjacent bundles or modules of fuel cells are connected together by mechanically joining their rigid members. The compliant/rigid connection permits construction of generator fuel cell stacks from basic modular groups of cells of any desired size. The connections can be made prior to installation of the fuel cells in a generator, thereby eliminating the need for in-situ completion of the connections. In addition to allowing pre-fabrication, the compliant/rigid connections also simplify removal and replacement of sections of a generator fuel cell stack.
NASA Astrophysics Data System (ADS)
Boiko, Andrey V.; Kulik, Victor M.; Chun, Ho-Hwan; Lee, Inwon
2011-12-01
Skin frictional drag reduction efficiency of "stiff" compliant coating was investigated in a wind tunnel experiment. Flat plate compliant coating inserts were installed in a wind tunnel and the measurements of skin frictional drag and velocity field were carried out. The compliant coatings with varying viscoelastic properties had been prepared using different composition. In order to optimize the coating thickness, the most important design parameter, the dynamic viscoelastic properties had been determined experimentally. The aging of the materials (variation of their properties) during half a year was documented as well. A design procedure proposed by Kulik et al. (2008) was applied to get an optimal value for the coating thickness. Along with the drag measurement using the strain balance, velocity and pressure were measured for different coatings. The compliant coatings with the thickness h = 7mm achieved 4~5% drag reduction within a velocity range 30~40 m/s. The drag reduction mechanism of the attenuation of turbulence velocity fluctuations due to the compliant coating was demonstrated. It is envisioned that larger drag reduction effect is obtainable at higher flow velocities for high speed trains and subsonic aircrafts.
NASA Astrophysics Data System (ADS)
Jiang, Yao; Li, Tie-Min; Wang, Li-Ping
2015-09-01
This paper investigates the stiffness modeling of compliant parallel mechanism (CPM) based on the matrix method. First, the general compliance matrix of a serial flexure chain is derived. The stiffness modeling of CPMs is next discussed in detail, considering the relative positions of the applied load and the selected displacement output point. The derived stiffness models have simple and explicit forms, and the input, output, and coupling stiffness matrices of the CPM can easily be obtained. The proposed analytical model is applied to the stiffness modeling and performance analysis of an XY parallel compliant stage with input and output decoupling characteristics. Then, the key geometrical parameters of the stage are optimized to obtain the minimum input decoupling degree. Finally, a prototype of the compliant stage is developed and its input axial stiffness, coupling characteristics, positioning resolution, and circular contouring performance are tested. The results demonstrate the excellent performance of the compliant stage and verify the effectiveness of the proposed theoretical model. The general stiffness models provided in this paper will be helpful for performance analysis, especially in determining coupling characteristics, and the structure optimization of the CPM.
A new hybrid piezo-actuated compliant mechanism with self-tuned flexure arm
NASA Astrophysics Data System (ADS)
Ling, Mingxiang; Cao, Junyi
2017-04-01
Recent interests and demands for developing video-rate atomic force microscopes, high-throughput probe-based nanofabrication and high-frequency vibration generator for assisted-machining are increasingly posing new challenges for designing high-bandwidth and large-range piezo-actuated compliant mechanisms. The previous studies mainly focused on making the trade-off between natural frequency and motion range by designing a proper topology. Differing from the previous works, this paper attempts to break the deadlock by employing both piezo-stacks and piezoelectric patches to actuate compliant mechanisms. In this method, piezo-stacks provide an actuating force similar to the traditional way, while piezoelectric patches are bonded on the surface of the flexure arms in compliant mechanisms. These `active' laminaes are used to further actuate the hosting flexural beam by inducing strains on the interface and then give additional bending moments to the flexural arms, which enlarge the output displacement of the compliant mechanism while without the sacrifice of natural frequency. An analytical formulation is established to illustrate the new driving principle and the compound static behaviour of a specific hybrid piezo-actuated multistage compliant mechanism. Initial prototype is also manufactured and experimentally testing is conducted to verify the feasibility of the method.
NASA Technical Reports Server (NTRS)
Forth, Katharine E.; Taylor, Laura C.; Paloski, William H.
2006-01-01
The purpose of the present experiment was to compare in normal human subjects the differential effects on postural stability of introducing somatosensory noise via compliant and/or sway-referenced support surfaces during quiet standing. The use of foam surfaces (two thicknesses: thin (0.95cm) and thick (7.62cm)) and sway-referenced support allowed comparison between two different types of destabilizing factors that increased ankle/foot somatosensory noise. Under some conditions neck extensions were used to increase sensory noise by deviating the vestibular system from its optimal orientation for balance control. The impact of these conditions on postural control was assessed through objective measures of instability. Thick foam and sway-referenced support conditions generated comparable instability in subjects, as measured by equilibrium score and minimum time-to-contact. However, simultaneous application of the conditions resulted in greater instability, suggesting a higher level of generated sensory noise and thus, different receptor types affected during each manipulation. Indeed, sway-referenced support generated greater anterior-posterior center-of-mass (COM) sway, while thick foam generated greater medio-lateral COM sway and velocity. Neck extension had minimal effect on postural stability until combined with simultaneous thick foam and sway-referenced support. Thin foam never generated enough sensory noise to affect postural stability even with noise added by sway-reference support or neck extension. These results provide an interesting window into the central integration of redundant sensory information and indicate the postural impact of sensory inputs is not solely based on their existence, but also their level of noise.
Short Communication: HIV Patient Systemic Mitochondrial Respiration Improves with Exercise.
Kocher, Morgan; McDermott, Mindy; Lindsey, Rachel; Shikuma, Cecilia M; Gerschenson, Mariana; Chow, Dominic C; Kohorn, Lindsay B; Hetzler, Ronald K; Kimura, Iris F
2017-10-01
In HIV-infected individuals, impaired mitochondrial function may contribute to cardiometabolic disease as well as to fatigue and frailty. Aerobic exercise improves total body energy reserves; however, its impact at the cellular level is unknown. We assessed alterations in cellular bioenergetics in peripheral blood mononuclear cells (PBMC) before and after a 12-week aerobic exercise study in sedentary HIV-infected subjects on stable antiretroviral therapy who successfully completed a 12-week aerobic exercise program. In this prospective study, participants underwent supervised 20-40 min of light aerobic exercise (walking or jogging) performed three times per week for 12 weeks, gradually increasing to maintain an intensity of 50%-80% of heart rate reserve. Maximal aerobic capacity (VO 2MAX ) was assessed by a graded exercise test on a cycle ergometer before and after completion of the study. PBMC from compliant subjects (attended at least 70% of exercise sessions) were assessed for mitochondrial respiration using the Seahorse XF24 Bio-Analyzer. Seven of 24 enrolled subjects were compliant with the exercise regimen. In these individuals, a significant increase (p = .04) in VO 2MAX over 12 weeks was found with a median increase of 14%. During the same interval, a 2.45-fold increase in PBMC mitochondrial respiratory capacity (p = .04), a 5.65-fold increase in spare respiratory capacity (p = .01), and a 3.15-fold (p = .04) increase in nonmitochondrial respiration was observed. Aerobic exercise improves respiration at the cellular level. The diagnostic and prognostic value of such improved cellular respiration in the setting of chronic HIV warrants further investigation.
Romero-Fernández, Ma Mar; Royo-Bordonada, Miguel Angel; Rodríguez-Artalejo, Fernando
2010-07-01
To evaluate the level of compliance with the PAOS Code (Publicidad, Actividad, Obesidad y Salud), which establishes standards for the self-regulation of food marketing aimed at minors, in television advertising by food and beverage companies that have agreed to abide by the Code. The study sample consisted of food and beverage advertisements targeting children during 80 h of programming by four Spanish television networks. The level of compliance with each standard of the PAOS Code was classified into three categories: 'compliance', 'non-compliance' and 'uncertain compliance'. Overall, an advertisement was considered compliant with the PAOS Code if it met all the standards; non-compliant if it contravened one or more standards; and uncertain in all other cases. Of a total of 203 television advertisements from companies that agreed to the PAOS Code, the overall prevalence of non-compliance was 49.3% (v. 50.8% among those that did not agree to the code), with 20.7% of advertisements considered of uncertain compliance. Non-compliance was more frequent on Saturdays, in longer advertisements, in advertisements containing promotions or dairy products, and for advertisements from companies of French or US origin. Non-compliance with the PAOS Code was very high and was similar for companies that did and did not agree to the Code, casting doubt on the Code's effectiveness and oversight system. It seems the time has come to commit to statutory regulations that reduce the negative impact of advertising on children's diets, as demanded by public health experts and consumer associations.
Semantic Overlays in Educational Content Networks--The hylOs Approach
ERIC Educational Resources Information Center
Engelhardt, Michael; Hildebrand, Arne; Lange, Dagmar; Schmidt, Thomas C.
2006-01-01
Purpose: The paper aims to introduce an educational content management system, Hypermedia Learning Objects System (hylOs), which is fully compliant to the IEEE LOM eLearning object metadata standard. Enabled through an advanced authoring toolset, hylOs allows the definition of instructional overlays of a given eLearning object mesh.…
Summary of International Border Crossings Roundtable Meeting Held in Buffalo, New York, June 7, 1993
DOT National Transportation Integrated Search
1996-11-30
The purpose of this plan is to establish a formal set of guidelines and activities to be adhered to and performed by JHU/APL and the developer to ensure that the SAFER System has been tested successfully and is fully compliant with the SAFER System r...
Many States unprepared for 'Y2K' computer woes.
1998-12-25
Most computer systems that States use to process health benefits are not Y2K compliant, which could jeopardize Medicaid application processing. This could cause recipients to lose benefits or experience delays in payments. Only seven states have reported that their systems are ready for the year 2000. Contact information is provided.
48 CFR 352.234-3 - Full earned value management system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Federal Agency (CFA) as being compliant with the guidelines in ANSI/EIA Standard-748 (current version at... and accepted by the CFA at the time of award, see paragraph (b) of this clause. The Contractor shall..., the Contractor's EVM system has not been validated and accepted by the CFA as complying with EVMS...
40 CFR 63.343 - Compliance provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (1) Composite mesh-pad systems. (i) During the initial performance test, the owner or operator of an... limitations in § 63.342 through the use of a composite mesh-pad system shall determine the outlet chromium... performance test and accept ±2 inches of water column from this value as the compliant range. (ii) On and...
40 CFR 63.343 - Compliance provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (1) Composite mesh-pad systems. (i) During the initial performance test, the owner or operator of an... limitations in § 63.342 through the use of a composite mesh-pad system shall determine the outlet chromium... performance test and accept ±2 inches of water column from this value as the compliant range. (ii) On and...
Telerobotic controller development
NASA Technical Reports Server (NTRS)
Otaguro, W. S.; Kesler, L. O.; Land, Ken; Rhoades, Don
1987-01-01
To meet NASA's space station's needs and growth, a modular and generic approach to robotic control which provides near-term implementation with low development cost and capability for growth into more autonomous systems was developed. The method uses a vision based robotic controller and compliant hand integrated with the Remote Manipulator System arm on the Orbiter. A description of the hardware and its system integration is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David Nix, Lisa Simirenko
2006-10-25
The Biolmaging Database (BID) is a relational database developed to store the data and meta-data for the 3D gene expression in early Drosophila embryo development on a cellular level. The schema was written to be used with the MySQL DBMS but with minor modifications can be used on any SQL compliant relational DBMS.
Why Are Some Reactions Slower at Higher Temperatures?
ERIC Educational Resources Information Center
Revell, Laura E.; Williamson, Bryce E.
2013-01-01
It is well understood by most chemistry students at advanced undergraduate levels that chemical reactions generally follow the Arrhenius law of temperature dependence with positive activation energies, proceeding faster at elevated temperatures. It is much less widely known that the rates of some Arrhenius-compliant reactions are retarded by…
COLLAGE: A Collaborative Learning Design Editor Based on Patterns
ERIC Educational Resources Information Center
Hernandez-Leo, Davinia; Villasclaras-Fernandez, Eloy D.; Asensio-Perez, Juan I.; Dimitriadis, Yannis; Jorrin-Abellan, Ivan M.; Ruiz-Requies, Ines; Rubia-Avi, Bartolome
2006-01-01
This paper introduces "Collage", a high-level IMS-LD compliant authoring tool that is specialized for CSCL (Computer-Supported Collaborative Learning). Nowadays CSCL is a key trend in e-learning since it highlights the importance of social interactions as an essential element of learning. CSCL is an interdisciplinary domain, which…
2011-01-01
Background The complexity and inter-related nature of biological data poses a difficult challenge for data and tool integration. There has been a proliferation of interoperability standards and projects over the past decade, none of which has been widely adopted by the bioinformatics community. Recent attempts have focused on the use of semantics to assist integration, and Semantic Web technologies are being welcomed by this community. Description SADI - Semantic Automated Discovery and Integration - is a lightweight set of fully standards-compliant Semantic Web service design patterns that simplify the publication of services of the type commonly found in bioinformatics and other scientific domains. Using Semantic Web technologies at every level of the Web services "stack", SADI services consume and produce instances of OWL Classes following a small number of very straightforward best-practices. In addition, we provide codebases that support these best-practices, and plug-in tools to popular developer and client software that dramatically simplify deployment of services by providers, and the discovery and utilization of those services by their consumers. Conclusions SADI Services are fully compliant with, and utilize only foundational Web standards; are simple to create and maintain for service providers; and can be discovered and utilized in a very intuitive way by biologist end-users. In addition, the SADI design patterns significantly improve the ability of software to automatically discover appropriate services based on user-needs, and automatically chain these into complex analytical workflows. We show that, when resources are exposed through SADI, data compliant with a given ontological model can be automatically gathered, or generated, from these distributed, non-coordinating resources - a behaviour we have not observed in any other Semantic system. Finally, we show that, using SADI, data dynamically generated from Web services can be explored in a manner very similar to data housed in static triple-stores, thus facilitating the intersection of Web services and Semantic Web technologies. PMID:22024447
Wilkinson, Mark D; Vandervalk, Benjamin; McCarthy, Luke
2011-10-24
The complexity and inter-related nature of biological data poses a difficult challenge for data and tool integration. There has been a proliferation of interoperability standards and projects over the past decade, none of which has been widely adopted by the bioinformatics community. Recent attempts have focused on the use of semantics to assist integration, and Semantic Web technologies are being welcomed by this community. SADI - Semantic Automated Discovery and Integration - is a lightweight set of fully standards-compliant Semantic Web service design patterns that simplify the publication of services of the type commonly found in bioinformatics and other scientific domains. Using Semantic Web technologies at every level of the Web services "stack", SADI services consume and produce instances of OWL Classes following a small number of very straightforward best-practices. In addition, we provide codebases that support these best-practices, and plug-in tools to popular developer and client software that dramatically simplify deployment of services by providers, and the discovery and utilization of those services by their consumers. SADI Services are fully compliant with, and utilize only foundational Web standards; are simple to create and maintain for service providers; and can be discovered and utilized in a very intuitive way by biologist end-users. In addition, the SADI design patterns significantly improve the ability of software to automatically discover appropriate services based on user-needs, and automatically chain these into complex analytical workflows. We show that, when resources are exposed through SADI, data compliant with a given ontological model can be automatically gathered, or generated, from these distributed, non-coordinating resources - a behaviour we have not observed in any other Semantic system. Finally, we show that, using SADI, data dynamically generated from Web services can be explored in a manner very similar to data housed in static triple-stores, thus facilitating the intersection of Web services and Semantic Web technologies.
Flexural anchorage performance at diagonal crack locations : final report.
DOT National Transportation Integrated Search
2010-12-01
Large numbers of reinforced concrete deck girder bridges that were constructed during the interstate system expansion of the 1950s have developed diagonal cracking in the stems. Though compliant with design codes when constructed, many of these bridg...
Optimal compliant-surface jumping: a multi-segment model of springboard standing jumps.
Cheng, Kuangyou B; Hubbard, Mont
2005-09-01
A multi-segment model is used to investigate optimal compliant-surface jumping strategies and is applied to springboard standing jumps. The human model has four segments representing the feet, shanks, thighs, and trunk-head-arms. A rigid bar with a rotational spring on one end and a point mass on the other end (the tip) models the springboard. Board tip mass, length, and stiffness are functions of the fulcrum setting. Body segments and board tip are connected by frictionless hinge joints and are driven by joint torque actuators at the ankle, knee, and hip. One constant (maximum isometric torque) and three variable functions (of instantaneous joint angle, angular velocity, and activation level) determine each joint torque. Movement from a nearly straight motionless initial posture to jump takeoff is simulated. The objective is to find joint torque activation patterns during board contact so that jump height can be maximized. Minimum and maximum joint angles, rates of change of normalized activation levels, and contact duration are constrained. Optimal springboard jumping simulations can reasonably predict jumper vertical velocity and jump height. Qualitatively similar joint torque activation patterns are found over different fulcrum settings. Different from rigid-surface jumping where maximal activation is maintained until takeoff, joint activation decreases near takeoff in compliant-surface jumping. The fulcrum-height relations in experimental data were predicted by the models. However, lack of practice at non-preferred fulcrum settings might have caused less jump height than the models' prediction. Larger fulcrum numbers are beneficial for taller/heavier jumpers because they need more time to extend joints.
Grandfathered, Grandmothered, And ACA-Compliant Health Plans Have Equivalent Premiums.
Whitmore, Heidi; Gabel, Jon R; Satorius, Jennifer L; Green, Matthew
2017-02-01
Many small employers offer employees health plans that are not fully compliant with Affordable Care Act (ACA) provisions such as covering preventive services without cost sharing. These "grandfathered" and "grandmothered" plans accounted for about 65 percent of enrollment in the small-group market in 2014. Premium costs for these and ACA-compliant plans were equivalent. Project HOPE—The People-to-People Health Foundation, Inc.
Hussein, Sami; Kruger, Jörg
2011-01-01
Robot assisted training has proven beneficial as an extension of conventional therapy to improve rehabilitation outcome. Further facilitation of this positive impact is expected from the application of cooperative control algorithms to increase the patient's contribution to the training effort according to his level of ability. This paper presents an approach for cooperative training for end-effector based gait rehabilitation devices. Thereby it provides the basis to firstly establish sophisticated cooperative control methods in this class of devices. It uses a haptic control framework to synthesize and render complex, task specific training environments, which are composed of polygonal primitives. Training assistance is integrated as part of the environment into the haptic control framework. A compliant window is moved along a nominal training trajectory compliantly guiding and supporting the foot motion. The level of assistance is adjusted via the stiffness of the moving window. Further an iterative learning algorithm is used to automatically adjust this assistance level. Stable haptic rendering of the dynamic training environments and adaptive movement assistance have been evaluated in two example training scenarios: treadmill walking and stair climbing. Data from preliminary trials with one healthy subject is provided in this paper. © 2011 IEEE
Active System for Electromagnetic Perturbation Monitoring in Vehicles
NASA Astrophysics Data System (ADS)
Matoi, Adrian Marian; Helerea, Elena
Nowadays electromagnetic environment is rapidly expanding in frequency domain and wireless services extend in terms of covered area. European electromagnetic compatibility regulations refer to limit values regarding emissions, as well as procedures for determining susceptibility of the vehicle. Approval procedure for a series of cars is based on determining emissions/immunity level for a few vehicles picked randomly from the entire series, supposing that entire vehicle series is compliant. During immunity assessment, the vehicle is not subjected to real perturbation sources, but exposed to electric/magnetic fields generated by laboratory equipment. Since current approach takes into account only partially real situation regarding perturbation sources, this paper proposes an active system for determining electromagnetic parameters of vehicle's environment, that implements a logical diagram for measurement, satisfying the imposed requirements. This new and original solution is useful for EMC assessment of hybrid and electrical vehicles.
A Fiber-Optic Interferometric Tri-Component Geophone for Ocean Floor Seismic Monitoring
Chen, Jiandong; Chang, Tianying; Fu, Qunjian; Lang, Jinpeng; Gao, Wenzhi; Wang, Zhongmin; Yu, Miao; Zhang, Yanbo; Cui, Hong-Liang
2016-01-01
For the implementation of an all fiber observation network for submarine seismic monitoring, a tri-component geophone based on Michelson interferometry is proposed and tested. A compliant cylinder-based sensor head is analyzed with finite element method and tested. The operation frequency ranges from 2 Hz to 150 Hz for acceleration detection, employing a phase generated carrier demodulation scheme, with a responsivity above 50 dB re rad/g for the whole frequency range. The transverse suppression ratio is about 30 dB. The system noise at low frequency originated mainly from the 1/f fluctuation, with an average system noise level −123.55 dB re rad/Hz ranging from 0 Hz to 500 Hz. The minimum detectable acceleration is about 2 ng/Hz, and the dynamic range is above 116 dB. PMID:28036011
NASA Astrophysics Data System (ADS)
Boettcher, M. A.; Butt, B. M.; Klinkner, S.
2016-10-01
A major concern of a university satellite mission is to download the payload and the telemetry data from a satellite. While the ground station antennas are in general easy and with limited afford to procure, the receiving unit is most certainly not. The flexible and low-cost software-defined radio (SDR) transceiver "BladeRF" is used to receive the QPSK modulated and CCSDS compliant coded data of a satellite in the HAM radio S-band. The control software is based on the Open Source program GNU Radio, which also is used to perform CCSDS post processing of the binary bit stream. The test results show a good performance of the receiving system.
A strain-isolation design for stretchable electronics
NASA Astrophysics Data System (ADS)
Wu, Jian; Li, Ming; Chen, Wei-Qiu; Kim, Dae-Hyeong; Kim, Yun-Soung; Huang, Yong-Gang; Hwang, Keh-Chih; Kang, Zhan; Rogers, John A.
2010-12-01
Stretchable electronics represents a direction of recent development in next-generation semiconductor devices. Such systems have the potential to offer the performance of conventional wafer-based technologies, but they can be stretched like a rubber band, twisted like a rope, bent over a pencil, and folded like a piece of paper. Isolating the active devices from strains associated with such deformations is an important aspect of design. One strategy involves the shielding of the electronics from deformation of the substrate through insertion of a compliant adhesive layer. This paper establishes a simple, analytical model and validates the results by the finite element method. The results show that a relatively thick, compliant adhesive is effective to reduce the strain in the electronics, as is a relatively short film.
Compliant mechanism road bicycle brake: a rigid-body replacement case study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olsen, Brian M; Howell, Larry L; Magleby, Spencer P
2011-01-19
The design of high-performance bicycle brakes is complicated by the competing design objectives of increased performance and low weight. But this challenge also provides a good case study to demonstrate the design of compliant mechanisms to replace current rigid-link mechanisms. This paper briefly reviews current road brake designs, demonstrates the use of rigid-body replacement synthesis to design a compliant mechanism, and illustrates the combination of compliant mechanism design tools. The resulting concept was generated from the modified dual-pivot brake design and is a partially compliant mechanism where one pin has the dual role of a joint and a mounting pin.more » The pseudo-rigid-body model, finite element analysis, and optimization algorithms are used to generate design dimensions, and designs are considered for both titanium and E-glass flexures. The resulting design has the potential of reducing the part count and overall weight while maintaining a performance similar to the benchmark.« less
Compliant-linkage kinematic design for multi-degree-of-freedom mobile robots
NASA Astrophysics Data System (ADS)
Borenstein, Johann
1993-05-01
Multi-degree-of-freedom (MDOF) vehicles have many potential advantages over conventional (i.e., 2-DOF) vehicles. For example, MDOF vehicles can travel sideways and they can negotiate tight turns more easily. In addition, some MDOF designs provide better payload capability, better traction, and improved static and dynamic stability. However, MDOF vehicles with more than three degrees-of-freedom are difficult to control because of their overconstrained nature. These difficulties translate into severe wheel slippage or jerky motion under certain driving conditions. In the past, these problems limited the use of MDOF vehicles to applications where the vehicle would follow a guide-wire, which would correct wheel slippage and control errors. By contrast, autonomous or semi-autonomous mobile robots usually rely on dead-reckoning between periodic absolute position updates and their performance is diminished by excessive wheel slippage. This paper introduces a new concept in the kinematic design of MDOF vehicles. This concept is based on the provision of a compliant linkage between drive wheels or drive axles. Simulation results indicate that compliant linkage allows to overcome the control problems found in conventional MDOF vehicles and reduces the amount of wheel slippage to the same level (or less) than the amount of slippage found on a comparable 2-DOF vehicle.
The catalogCleaner: Separating the Sheep from the Goats
NASA Astrophysics Data System (ADS)
O'Brien, K.; Hankin, S. C.; Schweitzer, R.; Koyuk, H.
2012-12-01
The Global Earth Observation Integrated Data Environment (GEO-IDE) is NOAA's effort to successfully integrate data and information with partners in the national US-Global Earth Observation System (US-GEO) and the international Global Earth Observation System of Systems (GEOSS). As part of the GEO-IDE, the Unified Access Framework (UAF) is working to build momentum towards the goal of increased data integration and interoperability. The UAF project is moving towards this goal with an approach that includes leveraging well known and widely used standards and focusing initially on well understood data types, such as gridded data from climate models. This phased approach serves to engage data providers and users and also has a high probability of demonstrable successes. The UAF project shares the widely held conviction that the use of data standards is a key ingredient necessary to achieve interoperability. Many community-based consensus standards fail, though, due to poor compliance. Compliance problems emerge for many reasons: because the standards evolve through versions, because documentation is ambiguous or because individual data providers find the standard inadequate as-is to meet their special needs. In addition, minimalist use of standards will lead to a compliant service, but one which is of low quality. For example, serving five hundred individual files from a single climate model might be compliant, but enhancing the service so that those files are all aggregated together into one virtual dataset and available through a single access URL provides a much more useful service. The UAF project began showcasing the advantages of providing compliant data by manually building a master catalog generated from hand-picked THREDDS servers. With an understanding that educating data managers to provide standards compliant data and metadata can take years, the UAF project wanted to continue increasing the volume of data served through the master catalog as much as possible. However, it quickly became obvious, through the sheer volume of data servers available, that the manual process of building a master catalog was not scalable. Thus, the idea for the catalogCleaner tool was born. The goal of this tool is to automatically crawl a remote OPeNDAP or THREDDS server, and from the information in the server build a "clean" catalog of data that will be: a) served through uniform access services; b) have CF compliant metadata; c) directly link the data to common visualization tools thereby allowing users to immediately begin exploring actual data. In addition, the UAF-generated clean catalog can then be used to drive data discovery tools such as Geoportal, GI-CAT, etc. This presentation will further explore the motivation of creating this tool, the implementation of this tool, as well as the myriad of challenges and difficulties there were encountered along the way.
NASA Astrophysics Data System (ADS)
Dutta, Rishabh; Wang, Teng; Feng, Guangcai; Harrington, Jonathan; Vasyura-Bathke, Hannes; Jónsson, Sigurjón
2017-04-01
Strain localizations in compliant fault zones (with elastic moduli lower than the surrounding rocks) induced by nearby earthquakes have been detected using geodetic observations in a few cases in the past. Here we observe small-scale changes in interferometric Synthetic Aperture Radar (InSAR) measurements along multiple conjugate faults near the rupture of the 2013 Mw7.7 Baluchistan (Pakistan) earthquake. After removing the main coseismic deformation signal in the interferograms and correcting them for topography-related phase, we observe 2-3 cm signal along several conjugate faults that are 15-30 km from the mainshock fault rupture. These conjugate compliant faults have strikes of N30°E and N45°W. The sense of motion indicates left-lateral deformation across the N30°E faults and right-lateral deformation across the N45°W faults, which suggests the conjugate faults were subjected to extensional coseismic stresses along the WSW-ENE direction. The spacing between the different sets of faults is around 5 to 8 km. We explain the observed strain localizations as an elastic response of the compliant conjugate faults induced by the Baluchistan earthquake. Using 3D Finite Element models (FEM), we impose coseismic static displacements due to the earthquake along the boundaries of the FEM domain to reproduce the coseismic stress changes acting across the compliant faults. The InSAR measurements are used to constrain the geometry and rigidity variations of the compliant faults with respect to the surrounding rocks. The best fitting models show the compliant fault zones to have a width of 0.5 km to 2 km and a reduction of the shear modulus by a factor of 3 to 4. Our study yields similar values as were found for compliant fault zones near the 1992 Landers and the 1999 Hector Mine earthquakes in California, although here the strain localization is occurring on more complex conjugate sets of faults.
A Dynamic Approach to Make CDS/ISIS Databases Interoperable over the Internet Using the OAI Protocol
ERIC Educational Resources Information Center
Jayakanth, F.; Maly, K.; Zubair, M.; Aswath, L.
2006-01-01
Purpose: A dynamic approach to making legacy databases, like CDS/ISIS, interoperable with OAI-compliant digital libraries (DLs). Design/methodology/approach: There are many bibliographic databases that are being maintained using legacy database systems. CDS/ISIS is one such legacy database system. It was designed and developed specifically for…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-08
... near zero. This circumstance, along with the compliant status of all other fabric and label components... 1\\1/4\\ inches. The area of the Label is insignificant with respect to the over two yards of fabric... system. Moreover, all other fabric, including other warning labels for the MyRide child restraint system...
48 CFR 352.234-4 - Partial earned value management system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Cognizant Federal Agency (CFA) as being compliant with the schedule-related guidelines in ANSI/EIA Standard... has not been validated and accepted by the CFA at the time of award, see paragraph (b) of this clause..., at the time of award, the Contractor's EVM system has not been validated and accepted by the CFA as...
MEMS scanner with 2D tilt, piston, and focus motion
NASA Astrophysics Data System (ADS)
Lani, S.; Bayat, D.; Petremand, Y.; Regamey, Y.-J.; Onillon, E.; Pierer, J.; Grossmann, S.
2017-02-01
A MEMS scanner with a high level of motion freedom has been developed. It includes a 2D mechanical tilting capability of +/- 15°, a piston motion of 50μm and a focus/defocus control system of a 2mm diameter mirror. The tilt and piston motion is achieved with an electromagnetic actuation (moving magnet) and the focus control with a deformation of the reflective surface with pneumatic actuation. This required the fabrication of at least one channel on the compliant membrane and a closed cavity below the mirror surface and connected to an external pressure regulator (vacuum to several bars). The fabrication relies on 3 SOI wafers, 2 for forming the compliant membranes and the integrated channel, and 1 to form the cavity mirror. All wafers were then assembled by fusion bonding. Pneumatic actuation for focus control can be achieved from front or back side; function of packaging concept. A reflective coating can be added at the mirror surface depending of the application. The tilt and piston actuation is achieved by electromagnetic actuation for which a magnet is fixed on the moving part of the MEMS device. Finally the MEMS device is mounted on a ceramic PCB, containing the actuation micro-coils. Concept, fabrication, and testing of the devices will be presented. A case study for application in an endoscope with an integrated high power laser and a MEMS steering mechanism will be presented.
Politis, Ioannis; Basbas, Socrates; Papaioannou, Panagiotis
2013-11-01
The objective of this paper is to examine a number of factors (observed and latent) that might have a causal effect on drinking and driving (D&D) behaviour. Face-to-face surveys were conducted among patrons at bars and cafeterias and 305 valid questionnaires were filled. A confirmatory factor analysis was performed so as to identify the latent constructs and a mixed structural equation model was developed. From the analysis it came up that non-compliant behaviour of D&D is limited at older ages, also associated with high levels of income and car availability. Though men are consuming more alcohol, women seem to be more prone in driving under the influence (DUI) of alcohol. Furthermore, it was found that people who strongly support the examined interventions in the study (e.g. better enforcement, more traffic safety campaigns, stricter penalties) are more unlikely to drive after drinking compare to those who have some objections. Finally, it was not found any statistically significant relation between individuals' level of awareness and D&D behaviour. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serageldin, M.A.
1999-07-01
The US Environmental Protection Agency is providing background information that supports the use of Metro Machine Corporation`s (MMC) compliant all position enclosure (CAPE) plus air management system and regenerative thermal oxidizer (RTO) (CAPE + RTO System) as an alternative means of limiting the emissions of volatile organic hazardous air pollutants per volume of applied solids (nonvolatiles). This document also explains how the authors arrived at the operating, recordkeeping, and reporting conditions that MMC must meet for approval. The add-on control system they used consists of a pollution capture unit operation (CAPE) plus air management system and a destruction unit operationmore » (RTO). When operated according to the specified procedures, it will control emissions to a level no greater than that from using coatings which comply with the limits in Table 2 of 40 CFR Part 63, Subpart II.« less
Could Blobs Fuel Storage-Based Convergence between HPC and Big Data?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matri, Pierre; Alforov, Yevhen; Brandon, Alvaro
The increasingly growing data sets processed on HPC platforms raise major challenges for the underlying storage layer. A promising alternative to POSIX-IO- compliant file systems are simpler blobs (binary large objects), or object storage systems. Such systems offer lower overhead and better performance at the cost of largely unused features such as file hierarchies or permissions. Similarly, blobs are increasingly considered for replacing distributed file systems for big data analytics or as a base for storage abstractions such as key-value stores or time-series databases. This growing interest in such object storage on HPC and big data platforms raises the question:more » Are blobs the right level of abstraction to enable storage-based convergence between HPC and Big Data? In this paper we study the impact of blob-based storage for real-world applications on HPC and cloud environments. The results show that blobbased storage convergence is possible, leading to a significant performance improvement on both platforms« less
Comparison of load distribution for implant overdenture attachments.
Porter, Joseph A; Petropoulos, Vicki C; Brunski, John B
2002-01-01
The aim of this study was to compare the force and moment distributions that develop on different implant overdenture attachments when vertical compressive forces are applied to an implant-retained overdenture. The following attachments were examined: Nobel Biocare bar and clip (NBC), Nobel Biocare standard ball (NSB), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor Advanced Generation (ZAAG), Sterngold ERA white (SEW), Sterngold ERA orange (SEO), Compliant Keeper System with titanium shims (CK-Ti), Compliant Keeper System with black nitrile 2SR90 sleeve rings (CK-70), and Compliant Keeper System with clear silicone 2SR90 sleeve rings (CK-90). The attachments were tested using custom strain-gauged abutments and 2 Brånemark System implants placed in a test model. Each attachment type had one part embedded in a denture-like housing and the other part (the abutment) screwed into the implants. Compressive static loads of 100 N were applied (1) bilaterally, over the distal midline (DM); (2) unilaterally, over the right implant (RI); (3) unilaterally, over the left implant (LI); and (4) between implants in the mid-anterior region (MA). Both the force and bending moment on each implant were recorded for each loading location and attachment type. Results were analyzed using 2-way analysis of variance and the Duncan multiple-range test. Both loading location and attachment type were statistically significant factors (P < .05). In general, the force and moment on an implant were greater when the load was applied directly over the implant or at MA. While not significant at every loading location, the largest implant forces tended to occur with ZAAG attachments; the smallest were found with the SEW, the SEO, the NSB, the CK-70, and the CK-90. Typically, higher moments existed for NBC and ZAAG, while lower moments existed for SEW, SEO, NSB, CK-90, and CK-70. For different loading locations, significant differences were found among the different overdenture attachment systems.
ENVIRONMENTALLY COMPLIANT CORROSION-ACTIVATED INHIBITOR SYSTEM FOR ALUMINUM ALLOYS - PHASE I
The federal government is estimated to spend $1 billion on painting/repainting aircraft annually. Aircraft have surfaces composed of aluminum alloys that are highly susceptible to corrosion and must be protected with corrosion-preventative treatments that typically conta...
Assistive and Autonomous Breast Ultrasound Screening: Improving PPV and Reducing RSI
imaging with quantitative elastography. Major objectives achieved in this period included development of a research platform including a compliant...This report details our first year of research activity on technologies that support sonographer-supervised robotic systems for breast ultrasound
77 FR 8326 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... 2010, FRA formed an Engineering Task Force (ETF) to develop crashworthiness criteria for an... system with other compliant Tier 1 equipments. The waiver petition includes documentation on the... Integrity Colliding Equipment Override Fluid Entry Inhibition End Structure Integrity of Cab End End...
Fang, Chenglong; Luo, Tingting; Lin, Ling
2017-12-01
We investigated whether serum CXC ligand 13 protein (CXCL13) levels correlate with the circulating plasmablasts and memory B-cells alteration in systemic lupus erythematosus (SLE) patients. The diagnostic use of CXCL13 concentrations in active lupus was also analyzed.A total of 36 SLE patients and 18 healthy controls were included. Serum CXCL13 levels were examined by enzyme-linked immunosorbent assay. The frequency and absolute count of circulating plasmablasts and memory B cells were analyzed by flow cytometry. Receiver operating characteristic curves (ROC curves) were generated to analyze the utility of serum CXCL13 level and plasmablasts frequency as tools for the recognition of active SLE.Elevation of serum CXCL13 levels, higher plasmablasts frequency, and reduction of memory B-cells count were observed in SLE patients, compared with healthy controls. Interestingly, correlational analyses showed not only significantly positive association between CXCL13 levels and SLE Disease Activity Index (SLEDAI) or plasmablasts frequency, but an inverse correlation between CXCL13 concentration and memory B-cell count. ROC curves showed that serum CXCL13 level and plasmablasts frequency were practical in identifying active disease from overall SLE patients, with considerable accuracy.Serum CXCL13 levels correlate with the alteration of plasmablasts and memory B cells in SLE. CXCL13 may be used as a practical tool in judgment of active SLE.
Theory of quantized systems: formal basis for DEVS/HLA distributed simulation environment
NASA Astrophysics Data System (ADS)
Zeigler, Bernard P.; Lee, J. S.
1998-08-01
In the context of a DARPA ASTT project, we are developing an HLA-compliant distributed simulation environment based on the DEVS formalism. This environment will provide a user- friendly, high-level tool-set for developing interoperable discrete and continuous simulation models. One application is the study of contract-based predictive filtering. This paper presents a new approach to predictive filtering based on a process called 'quantization' to reduce state update transmission. Quantization, which generates state updates only at quantum level crossings, abstracts a sender model into a DEVS representation. This affords an alternative, efficient approach to embedding continuous models within distributed discrete event simulations. Applications of quantization to message traffic reduction are discussed. The theory has been validated by DEVSJAVA simulations of test cases. It will be subject to further test in actual distributed simulations using the DEVS/HLA modeling and simulation environment.
Improving the Level and Quality of Ethics Review in Chinese Medicine and Integrative Medicine.
Zhang, Cheng-Bin; Li, En-Chang
2018-04-01
Three features of ethics review in Chinese medicine (CM) and integrative medicine (IM) were put forward in this paper. It is consistent with the principles of ethical review in Western medicine; it has to be compliant with the laws of CM and IM; emphasis should be laid on the review of clinical practice facts and experience. Three problems were pointed out. The characteristics of CM and IM are not distinctive enough, operation procedures need to be refined and effectiveness remains to be improved. Based on the mentioned above, seven measures were proposed to improve the level and quality of ethics review in CM and IM, including better brand awareness, considerable tolerance, treatment based on disease differentiation and syndrome differentiation, scientific review and toxicity and side effects of CM, perfection of the ethics review system, reasonable procedures of ethics review and more specialized ethics review workers.
Performance characterization of structured light-based fingerprint scanner
NASA Astrophysics Data System (ADS)
Hassebrook, Laurence G.; Wang, Minghao; Daley, Raymond C.
2013-05-01
Our group believes that the evolution of fingerprint capture technology is in transition to include 3-D non-contact fingerprint capture. More specifically we believe that systems based on structured light illumination provide the highest level of depth measurement accuracy. However, for these new technologies to be fully accepted by the biometric community, they must be compliant with federal standards of performance. At present these standards do not exist for this new biometric technology. We propose and define a set of test procedures to be used to verify compliance with the Federal Bureau of Investigation's image quality specification for Personal Identity Verification single fingerprint capture devices. The proposed test procedures include: geometric accuracy, lateral resolution based on intensity or depth, gray level uniformity and flattened fingerprint image quality. Several 2-D contact analogies, performance tradeoffs and optimization dilemmas are evaluated and proposed solutions are presented.
Validation of the Spanish Acne Severity Scale (Escala de Gravedad del Acné Española--EGAE).
Puig, Lluis; Guerra-Tapia, Aurora; Conejo-Mir, Julián; Toribio, Jaime; Berasategui, Carmen; Zsolt, Ilonka
2013-04-01
Several acne grading systems have been described, but consensus is lacking on which shows superiority. A standardized system would facilitate therapeutic decisions and the analysis of clinical trial data. To assess the feasibility, reliability, validity and sensitivity to change of the Spanish Acne Severity Scale (EGAE). A Spanish, multicentre, prospective, observational study was performed in patients with facial, back or chest acne assessed using EGAE, Leeds Revised Acne Grading system (LRAG) and lesion count. Clinicians answered 4 questions regarding EGAE use and time employed. Patients were evaluated at baseline and after 5±1 weeks. Four additional blinded observers, all dermatologists, evaluated patients' pictures using EGAE and LRAG. In total, 349 acne locations were assessed in 328 patients. Of the dermatologists, 95.6% (CI: 92.9-97.5%) reported that EGAE was easy to use, and 75% used it in <3 minutes. Interobserver reliability of the EGAE scale was shown by a Kendall's W of 0.773 (p<0.001). EGAE and LRAG scales showed a high correlation (Spearman's correlation>0.85; p<0.001). EGAE mean score in treatment-compliant patients was significantly lower at follow-up than at baseline (2.14 vs. 1.57, p<0.001, Cohen's d=0.35).The pre-post-treatment difference in EGAE mean score in non-compliant patients was not significant (1.44 vs. 1.32, p<0.102) and Cohen's d was lower (0.19) than in compliant patients. The use of EGAE to evaluate acne grade in daily clinical dermatological practice in Spanish centres has shown feasibility, high interobserver reliability, concurrent validity and sensitivity to detect treatment effects.
NASA Astrophysics Data System (ADS)
Li, Guo-Yang; Xu, Guoqiang; Zheng, Yang; Cao, Yanping
2018-03-01
Surface acoustic wave (SAW) devices have found a wide variety of technical applications, including SAW filters, SAW resonators, microfluidic actuators, biosensors, flow measurement devices, and seismic wave shields. Stretchable/flexible electronic devices, such as sensory skins for robotics, structural health monitors, and wearable communication devices, have received considerable attention across different disciplines. Flexible SAW devices are essential building blocks for these applications, wherein piezoelectric films may need to be integrated with the compliant substrates. When piezoelectric films are much stiffer than soft substrates, SAWs are usually leaky and the devices incorporating them suffer from acoustic losses. In this study, the propagation of SAWs in a wrinkled bilayer system is investigated, and our analysis shows that non-leaky modes can be achieved by engineering stress patterns through surface wrinkles in the system. Our analysis also uncovers intriguing bandgaps (BGs) related to the SAWs in a wrinkled bilayer system; these are caused by periodic deformation patterns, which indicate that diverse wrinkling patterns could be used as metasurfaces for controlling the propagation of SAWs.
NASA Astrophysics Data System (ADS)
Joslin, R. D.
1991-04-01
The use of passive devices to obtain drag and noise reduction or transition delays in boundary layers is highly desirable. One such device that shows promise for hydrodynamic applications is the compliant coating. The present study extends the mechanical model to allow for three-dimensional waves. This study also looks at the effect of compliant walls on three-dimensional secondary instabilities. For the primary and secondary instability analysis, spectral and shooting approximations are used to obtain solutions of the governing equations and boundary conditions. The spectral approximation consists of local and global methods of solution while the shooting approach is local. The global method is used to determine the discrete spectrum of eigenvalue without any initial guess. The local method requires a sufficiently accurate initial guess to converge to the eigenvalue. Eigenvectors may be obtained with either local approach. For the initial stage of this analysis, two and three dimensional primary instabilities propagate over compliant coatings. Results over the compliant walls are compared with the rigid wall case. Three-dimensional instabilities are found to dominate transition over the compliant walls considered. However, transition delays are still obtained and compared with transition delay predictions for rigid walls. The angles of wave propagation are plotted with Reynolds number and frequency. Low frequency waves are found to be highly three-dimensional.
Development of a multistage compliant mechanism with new boundary constraint
NASA Astrophysics Data System (ADS)
Ling, Mingxiang; Cao, Junyi; Jiang, Zhou; Li, Qisheng
2018-01-01
This paper presents a piezo-actuated compliant mechanism with a new boundary constraint to provide concurrent large workspace and high dynamic frequency for precision positioning or other flexible manipulation applications. A two-stage rhombus-type displacement amplifier with the "sliding-sliding" boundary constraint is presented to maximize the dynamic frequency while retaining a large output displacement. The vibration mode is also improved by the designed boundary constraint. A theoretical kinematic model of the compliant mechanism is established to optimize the geometric parameters, and a prototype is fabricated with a compact dimension of 60 mm × 60 mm × 12 mm. The experimental testing shows that the maximum stroke is approximately 0.6 mm and the output stiffness is 1.1 N/μm with the fundamental frequency of larger than 2.2 kHz. Lastly, the excellent performance of the presented compliant mechanism is compared with several mechanisms in the previous literature. As a conclusion, the presented boundary constraint strategy provides a new way to balance the trade-off between the frequency response and the stroke range widely existed in compliant mechanisms.
DNA origami compliant nanostructures with tunable mechanical properties.
Zhou, Lifeng; Marras, Alexander E; Su, Hai-Jun; Castro, Carlos E
2014-01-28
DNA origami enables fabrication of precise nanostructures by programming the self-assembly of DNA. While this approach has been used to make a variety of complex 2D and 3D objects, the mechanical functionality of these structures is limited due to their rigid nature. We explore the fabrication of deformable, or compliant, objects to establish a framework for mechanically functional nanostructures. This compliant design approach is used in macroscopic engineering to make devices including sensors, actuators, and robots. We build compliant nanostructures by utilizing the entropic elasticity of single-stranded DNA (ssDNA) to locally bend bundles of double-stranded DNA into bent geometries whose curvature and mechanical properties can be tuned by controlling the length of ssDNA strands. We demonstrate an ability to achieve a wide range of geometries by adjusting a few strands in the nanostructure design. We further developed a mechanical model to predict both geometry and mechanical properties of our compliant nanostructures that agrees well with experiments. Our results provide a basis for the design of mechanically functional DNA origami devices and materials.
Common Badging and Access Control System (CBACS)
NASA Technical Reports Server (NTRS)
Dischinger, Portia
2005-01-01
This slide presentation presents NASA's Common Badging and Access Control System. NASA began a Smart Card implementation in January 2004. Following site surveys, it was determined that NASA's badging and access control systems required upgrades to common infrastructure in order to provide flexibly, usability, and return on investment prior to a smart card implantation. Common Badging and Access Control System (CBACS) provides the common infrastructure from which FIPS-201 compliant processes, systems, and credentials can be developed and used.
DOT National Transportation Integrated Search
2015-02-01
Through a coordinated effort among the electrical engineering research team of the Florida State : University (FSU) and key Florida Department of Transportation (FDOT) personnel, an NTCIP-based : automated testing system for NTCIP-compliant ASC has b...
48 CFR 352.239-71 - Standard for encryption language.
Code of Federal Regulations, 2011 CFR
2011-10-01
... language. 352.239-71 Section 352.239-71 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES... Information Processing Standard (FIPS) 140-2-compliant encryption (Security Requirements for Cryptographic Module, as amended) to protect all instances of HHS sensitive information during storage and transmission...
Ocular drug delivery systems: An overview
Patel, Ashaben; Cholkar, Kishore; Agrahari, Vibhuti; Mitra, Ashim K
2014-01-01
The major challenge faced by today’s pharmacologist and formulation scientist is ocular drug delivery. Topical eye drop is the most convenient and patient compliant route of drug administration, especially for the treatment of anterior segment diseases. Delivery of drugs to the targeted ocular tissues is restricted by various precorneal, dynamic and static ocular barriers. Also, therapeutic drug levels are not maintained for longer duration in target tissues. In the past two decades, ocular drug delivery research acceleratedly advanced towards developing a novel, safe and patient compliant formulation and drug delivery devices/techniques, which may surpass these barriers and maintain drug levels in tissues. Anterior segment drug delivery advances are witnessed by modulation of conventional topical solutions with permeation and viscosity enhancers. Also, it includes development of conventional topical formulations such as suspensions, emulsions and ointments. Various nanoformulations have also been introduced for anterior segment ocular drug delivery. On the other hand, for posterior ocular delivery, research has been immensely focused towards development of drug releasing devices and nanoformulations for treating chronic vitreoretinal diseases. These novel devices and/or formulations may help to surpass ocular barriers and associated side effects with conventional topical drops. Also, these novel devices and/or formulations are easy to formulate, no/negligibly irritating, possess high precorneal residence time, sustain the drug release, and enhance ocular bioavailability of therapeutics. An update of current research advancement in ocular drug delivery necessitates and helps drug delivery scientists to modulate their think process and develop novel and safe drug delivery strategies. Current review intends to summarize the existing conventional formulations for ocular delivery and their advancements followed by current nanotechnology based formulation developments. Also, recent developments with other ocular drug delivery strategies employing in situ gels, implants, contact lens and microneedles have been discussed. PMID:25590022
Ocular drug delivery systems: An overview.
Patel, Ashaben; Cholkar, Kishore; Agrahari, Vibhuti; Mitra, Ashim K
The major challenge faced by today's pharmacologist and formulation scientist is ocular drug delivery. Topical eye drop is the most convenient and patient compliant route of drug administration, especially for the treatment of anterior segment diseases. Delivery of drugs to the targeted ocular tissues is restricted by various precorneal, dynamic and static ocular barriers. Also, therapeutic drug levels are not maintained for longer duration in target tissues. In the past two decades, ocular drug delivery research acceleratedly advanced towards developing a novel, safe and patient compliant formulation and drug delivery devices/techniques, which may surpass these barriers and maintain drug levels in tissues. Anterior segment drug delivery advances are witnessed by modulation of conventional topical solutions with permeation and viscosity enhancers. Also, it includes development of conventional topical formulations such as suspensions, emulsions and ointments. Various nanoformulations have also been introduced for anterior segment ocular drug delivery. On the other hand, for posterior ocular delivery, research has been immensely focused towards development of drug releasing devices and nanoformulations for treating chronic vitreoretinal diseases. These novel devices and/or formulations may help to surpass ocular barriers and associated side effects with conventional topical drops. Also, these novel devices and/or formulations are easy to formulate, no/negligibly irritating, possess high precorneal residence time, sustain the drug release, and enhance ocular bioavailability of therapeutics. An update of current research advancement in ocular drug delivery necessitates and helps drug delivery scientists to modulate their think process and develop novel and safe drug delivery strategies. Current review intends to summarize the existing conventional formulations for ocular delivery and their advancements followed by current nanotechnology based formulation developments. Also, recent developments with other ocular drug delivery strategies employing in situ gels, implants, contact lens and microneedles have been discussed.
Force-reflection and shared compliant control in operating telemanipulators with time delay
NASA Technical Reports Server (NTRS)
Kim, Won S.; Hannaford, Blake; Bejczy, Antal K.
1992-01-01
The performance of an advanced telemanipulation system in the presence of a wide range of time delays between a master control station and a slave robot is quantified. The contemplated applications include multiple satellite links to LEO, geosynchronous operation, spacecraft local area networks, and general-purpose computer-based short-distance designs. The results of high-precision peg-in-hole tasks performed by six test operators indicate that task performance decreased linearly with introduced time delays for both kinesthetic force feedback (KFF) and shared compliant control (SCC). The rate of this decrease was substantially improved with SCC compared to KFF. Task performance at delays above 1 s was not possible using KFF. SCC enabled task performance for such delays, which are realistic values for ground-controlled remote manipulation of telerobots in space.
Parameter Optimization of Pseudo-Rigid-Body Models of MRI-Actuated Catheters
Greigarn, Tipakorn; Liu, Taoming; Çavuşoğlu, M. Cenk
2016-01-01
Simulation and control of a system containing compliant mechanisms such as cardiac catheters often incur high computational costs. One way to reduce the costs is to approximate the mechanisms with Pseudo-Rigid-Body Models (PRBMs). A PRBM generally consists of rigid links connected by spring-loaded revolute joints. The lengths of the rigid links and the stiffnesses of the springs are usually chosen to minimize the tip deflection differences between the PRBM and the compliant mechanism. In most applications, only the relationship between end load and tip deflection is considered. This is obviously not applicable for MRI-actuated catheters which is actuated by the coils attached to the body. This paper generalizes PRBM parameter optimization to include loading and reference points along the body. PMID:28261009
NASA Astrophysics Data System (ADS)
Dabiri, Arman; Butcher, Eric A.; Nazari, Morad
2017-02-01
Compliant impacts can be modeled using linear viscoelastic constitutive models. While such impact models for realistic viscoelastic materials using integer order derivatives of force and displacement usually require a large number of parameters, compliant impact models obtained using fractional calculus, however, can be advantageous since such models use fewer parameters and successfully capture the hereditary property. In this paper, we introduce the fractional Chebyshev collocation (FCC) method as an approximation tool for numerical simulation of several linear fractional viscoelastic compliant impact models in which the overall coefficient of restitution for the impact is studied as a function of the fractional model parameters for the first time. Other relevant impact characteristics such as hysteresis curves, impact force gradient, penetration and separation depths are also studied.
Goto, Takaaki; Dobashi, Hiroki; Yoshikawa, Tsuneo; Loureiro, Rui C V; Harwin, William S; Miyamura, Yuga; Nagai, Kiyoshi
2017-07-01
This paper addresses the mechanical structure and control method of a redundant drive robot (RDR) to produce compliant motions, and show how the design parameters of the RDR can effect the produced motions and the mechanical and performance limitations of the actuators of the RDR. The structure and control method of the RDR can have been proper to produce compliant motions, but the effect of the design parameters of the RDR to the mechanical and performance limitations have not been clear. Therefore, the feasibility of producing compliant motions in the case of the prototype of the RDR is confirmed by conducting simulations and experiments, and then the design parameters of the RDR to the mechanical and performance limitations are verified by conducting simulations.
NASA Astrophysics Data System (ADS)
Gray, Bonnie L.
2012-04-01
Microfluidics is revolutionizing laboratory methods and biomedical devices, offering new capabilities and instrumentation in multiple areas such as DNA analysis, proteomics, enzymatic analysis, single cell analysis, immunology, point-of-care medicine, personalized medicine, drug delivery, and environmental toxin and pathogen detection. For many applications (e.g., wearable and implantable health monitors, drug delivery devices, and prosthetics) mechanically flexible polymer devices and systems that can conform to the body offer benefits that cannot be achieved using systems based on conventional rigid substrate materials. However, difficulties in implementing active devices and reliable packaging technologies have limited the success of flexible microfluidics. Employing highly compliant materials such as PDMS that are typically employed for prototyping, we review mechanically flexible polymer microfluidic technologies based on free-standing polymer substrates and novel electronic and microfluidic interconnection schemes. Central to these new technologies are hybrid microfabrication methods employing novel nanocomposite polymer materials and devices. We review microfabrication methods using these materials, along with demonstrations of example devices and packaging schemes that employ them. We review these recent developments and place them in the context of the fields of flexible microfluidics and conformable systems, and discuss cross-over applications to conventional rigid-substrate microfluidics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alvarez, P; Molineu, A; Lowenstein, J
Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specificmore » geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI.« less
Interoperability and security in wireless body area network infrastructures.
Warren, Steve; Lebak, Jeffrey; Yao, Jianchu; Creekmore, Jonathan; Milenkovic, Aleksandar; Jovanov, Emil
2005-01-01
Wireless body area networks (WBANs) and their supporting information infrastructures offer unprecedented opportunities to monitor state of health without constraining the activities of a wearer. These mobile point-of-care systems are now realizable due to the convergence of technologies such as low-power wireless communication standards, plug-and-play device buses, off-the-shelf development kits for low-power microcontrollers, handheld computers, electronic medical records, and the Internet. To increase acceptance of personal monitoring technology while lowering equipment cost, advances must be made in interoperability (at both the system and device levels) and security. This paper presents an overview of WBAN infrastructure work in these areas currently underway in the Medical Component Design Laboratory at Kansas State University (KSU) and at the University of Alabama in Huntsville (UAH). KSU efforts include the development of wearable health status monitoring systems that utilize ISO/IEEE 11073, Bluetooth, Health Level 7, and OpenEMed. WBAN efforts at UAH include the development of wearable activity and health monitors that incorporate ZigBee-compliant wireless sensor platforms with hardware-level encryption and the TinyOS development environment. WBAN infrastructures are complex, requiring many functional support elements. To realize these infrastructures through collaborative efforts, organizations such as KSU and UAH must define and utilize standard interfaces, nomenclature, and security approaches.
Aeroelastic Airworthiness Assesment of the Adaptive Compliant Trailing Edge Flaps
NASA Technical Reports Server (NTRS)
Herrera, Claudia Y.; Spivey, Natalie D.; Lung, Shun-fat; Ervin, Gregory; Flick, Peter
2015-01-01
The Adaptive Compliant Trailing Edge (ACTE) demonstrator is a joint task under the National Aeronautics and Space Administration Environmentally Responsible Aviation Project in partnership with the Air Force Research Laboratory and FlexSys, Inc. (Ann Arbor, Michigan). The project goal is to develop advanced technologies that enable environmentally friendly aircraft, such as adaptive compliant technologies. The ACTE demonstrator flight-test program encompassed replacing the Fowler flaps on the SubsoniC Aircraft Testbed, a modified Gulfstream III (Gulfstream Aerospace, Savannah, Georgia) aircraft, with control surfaces developed by FlexSys. The control surfaces developed by FlexSys are a pair of uniquely-designed unconventional flaps to be used as lifting surfaces during flight-testing to validate their structural effectiveness. The unconventional flaps required a multidisciplinary airworthiness assessment to prove they could withstand the prescribed flight envelope. Several challenges were posed due to the large deflections experienced by the structure, requiring non-linear analysis methods. The aeroelastic assessment necessitated both conventional and extensive testing and analysis methods. A series of ground vibration tests (GVTs) were conducted to provide modal characteristics to validate and update finite element models (FEMs) used for the flutter analyses for a subset of the various flight configurations. Numerous FEMs were developed using data from FlexSys and the ground tests. The flap FEMs were then attached to the aircraft model to generate a combined FEM that could be analyzed for aeroelastic instabilities. The aeroelastic analysis results showed the combined system of aircraft and flaps were predicted to have the required flutter margin to successfully demonstrate the adaptive compliant technology. This paper documents the details of the aeroelastic airworthiness assessment described, including the ground testing and analyses, and subsequent flight-testing performed on the unconventional ACTE flaps.
Smart structure with elastomeric contact surface for prosthetic fingertip sensitivity development
NASA Astrophysics Data System (ADS)
Gu, Chunxin; Liu, Weiting; Yu, Ping; Cheng, Xiaoying; Fu, Xin
2017-09-01
Current flexible/compliant tactile sensors suffer from low sensitivity and high hysteresis introduced by the essential viscosity characteristic of soft material, either used as compliant sensing element or as flexible coverage. To overcome these disadvantages, this paper focuses on developing a tactile sensor with a smart hybrid structure to obtain comprehensive properties in terms of size, compliance, robustness and pressure sensing ability so as to meet the requirements of limited space applications such as prosthetic fingertips. Employing micro-fabricated tiny silicon-based pressure die as the sensing element, it is easy to have both small size and good mechanical performance. To protect it from potential damage and maintain the compliant surface, a rigid base and a soft layer form a sealed chamber and encapsulate the fixed die together with fluid. The fluid serves as highly efficient pressure propagation media of mechanical stimulus from the compliant skin to the pressure die without any hazard impacting the vulnerable connecting wires. To understand the pressure transmission mechanism, a simplified and concise analytic model of a spring system is proposed. Using easy fabrication technologies, a prototype of a 3 × 3 sensor array with total dimensions of 14 mm × 14 mm × 6.5 mm was developed. Based on the quasi-linear relationship between fluid volume and pressure, finite element modeling was developed to analyze the chamber deformation and pressure output of the sensor cell. Experimental tests of the sensor prototype were implemented. The results showed that the sensor cell had good sensing performance with sensitivity of 19.9 mV N-1, linearity of 0.998, repeatability error of 3.41%, and hysteresis error of 3.34%. The force sensing range was from 5 mN to 1.6 N.
NASA Technical Reports Server (NTRS)
Smith, Mark S.; Bui, Trong T.; Garcia, Christian A.; Cumming, Stephen B.
2016-01-01
A pair of compliant trailing edge flaps was flown on a modified GIII airplane. Prior to flight test, multiple analysis tools of various levels of complexity were used to predict the aerodynamic effects of the flaps. Vortex lattice, full potential flow, and full Navier-Stokes aerodynamic analysis software programs were used for prediction, in addition to another program that used empirical data. After the flight-test series, lift and pitching moment coefficient increments due to the flaps were estimated from flight data and compared to the results of the predictive tools. The predicted lift increments matched flight data well for all predictive tools for small flap deflections. All tools over-predicted lift increments for large flap deflections. The potential flow and Navier-Stokes programs predicted pitching moment coefficient increments better than the other tools.
Hygroscopic motions of fossil conifer cones
NASA Astrophysics Data System (ADS)
Poppinga, Simon; Nestle, Nikolaus; Šandor, Andrea; Reible, Bruno; Masselter, Tom; Bruchmann, Bernd; Speck, Thomas
2017-01-01
Conifer cones represent natural, woody compliant structures which move their scales as passive responses to changes in environmental humidity. Here we report on water-driven opening and closing motions in coalified conifer cones from the Eemian Interglacial (approx. 126,000-113,000 years BP) and from the Middle Miocene (approx. 16.5 to 11.5 million years BP). These cones represent by far the oldest documented evidence of plant parts showing full functionality of such passive hydraulically actuated motion. The functional resilience of these structures is far beyond the biological purpose of seed dispersal and protection and is because of a low level of mineralization of the fossils. Our analysis emphasizes the functional-morphological integrity of these biological compliant mechanisms which, in addition to their biological fascination, are potentially also role models for resilient and maintenance-free biomimetic applications (e.g., adaptive and autonomously moving structures including passive hydraulic actuators).
NASA Technical Reports Server (NTRS)
Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc
2014-01-01
In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a Qualification Model. The selected linear Slit Change Mechanism design concept, consisting of a flexible guiding system driven by a hermetically sealed linear drive mechanism, is considered validated for the specific application of the SPICE instrument, with great potential for other special applications where contamination and high precision positioning are dominant design drivers.
Khan, Wajahat Ali; Khattak, Asad Masood; Hussain, Maqbool; Amin, Muhammad Bilal; Afzal, Muhammad; Nugent, Christopher; Lee, Sungyoung
2014-08-01
Heterogeneity in the management of the complex medical data, obstructs the attainment of data level interoperability among Health Information Systems (HIS). This diversity is dependent on the compliance of HISs with different healthcare standards. Its solution demands a mediation system for the accurate interpretation of data in different heterogeneous formats for achieving data interoperability. We propose an adaptive AdapteR Interoperability ENgine mediation system called ARIEN, that arbitrates between HISs compliant to different healthcare standards for accurate and seamless information exchange to achieve data interoperability. ARIEN stores the semantic mapping information between different standards in the Mediation Bridge Ontology (MBO) using ontology matching techniques. These mappings are provided by our System for Parallel Heterogeneity (SPHeRe) matching system and Personalized-Detailed Clinical Model (P-DCM) approach to guarantee accuracy of mappings. The realization of the effectiveness of the mappings stored in the MBO is evaluation of the accuracy in transformation process among different standard formats. We evaluated our proposed system with the transformation process of medical records between Clinical Document Architecture (CDA) and Virtual Medical Record (vMR) standards. The transformation process achieved over 90 % of accuracy level in conversion process between CDA and vMR standards using pattern oriented approach from the MBO. The proposed mediation system improves the overall communication process between HISs. It provides an accurate and seamless medical information exchange to ensure data interoperability and timely healthcare services to patients.
NASA Astrophysics Data System (ADS)
Mytych, Joanna; Ligarski, Mariusz J.
2018-03-01
The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.
Dugas, Martin
2016-11-29
Clinical trials use many case report forms (CRFs) per patient. Because of the astronomical number of potential CRFs, data element re-use at the design stage is attractive to foster compatibility of data from different trials. The objective of this work is to assess the technical feasibility of a CRF editor with connection to a public metadata registry (MDR) to support data element re-use. Based on the Medical Data Models portal, an ISO/IEC 11179-compliant MDR was implemented and connected to a web-based CRF editor. Three use cases were implemented: re-use at the form, item group and data element levels. CRF design with data element re-use from a public MDR is feasible. A prototypic system is available. The main limitation of the system is the amount of available MDR content.
NASA Astrophysics Data System (ADS)
Kolari, K.; Havia, T.; Stuns, I.; Hjort, K.
2014-08-01
Restrictor valves allow proportional control of fluid flow but are rarely integrated in microfluidic systems. In this study, an optically actuated silicon membrane restrictor microvalve is demonstrated. Its actuation is based on the phase transition of paraffin, using a paraffin wax mixed with a suitable concentration of optically absorbing nanographite particles. Backing up the membrane with oil (the melted paraffin) allows for a compliant yet strong contact to the valve seat, which enables handling of high pressures. At flow rates up to 30 µL min-1 and at a pressure of 2 bars, the valve can successfully be closed and control the flow level by restriction. The use of this paraffin composite as an adhesive layer sandwiched between the silicon valve and glass eases fabrication. This type of restrictor valve is best suited for high pressure, low volume flow silicon-based nanofluidic systems.
High Misalignment Carbon Seals for the Fan Drive Gear System Technologies
NASA Technical Reports Server (NTRS)
Shaughnessy, Dennis; Dobek, Lou
2006-01-01
Aircraft engines of the future will require capability bearing compartment seals than found in current engines. Geared systems driving the fan will be subjected to inertia and gyroscopic forces resulting in extremely high angular and radial misalignments. Because of the high misalignment levels, compartment seals capable of accommodating angularities and eccentricities are required. Pratt & Whitney and Stein Seal Company selected the segmented circumferential carbon seal as the best candidate to operate at highly misaligned conditions. Initial seal tests established the misalignment limits of the current technology circumferential seal. From these results a more compliant seal configuration was conceived, designed, fabricated, and tested. Further improvements to the design are underway and plans are to conduct a durability test of the next phase configuration. A technical approach is presented, including design modification to a "baseline"seal, carbon grade selection, test rig configuration, test plan and results of analysis of seal testing.
Visit from JAXA to NASA MSFC: The Engines Element & Ideas for Collaboration
NASA Technical Reports Server (NTRS)
Greene, William D.
2013-01-01
System Design, Development, and Fabrication: Design, develop, and fabricate or procure MB-60 component hardware compliant with the imposed technical requirements and in sufficient quantities to fulfill the overall MB-60 development effort. System Development, Assembly, and Test: Manage the scope of the development, assembly, and test-related activities for MB-60 development. This scope includes engine-level development planning, engine assembly and disassembly, test planning, engine testing, inspection, anomaly resolution, and development of necessary ground support equipment and special test equipment. System Integration: Provide coordinated integration in the realms of engineering, safety, quality, and manufacturing disciplines across the scope of the MB-60 design and associated products development Safety and Mission Assurance, structural design, fracture control, materials and processes, thermal analysis. Systems Engineering and Analysis: Manage and perform Systems Engineering and Analysis to provide rigor and structure to the overall design and development effort for the MB-60. Milestone reviews, requirements management, system analysis, program management support Program Management: Manage, plan, and coordinate the activities across all portions of the MB-60 work scope by providing direction for program administration, business management, and supplier management.
Motivation and Design of the Sirocco Storage System Version 1.0.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curry, Matthew Leon; Ward, H. Lee; Danielson, Geoffrey Charles
Sirocco is a massively parallel, high performance storage system for the exascale era. It emphasizes client-to-client coordination, low server-side coupling, and free data movement to improve resilience and performance. Its architecture is inspired by peer-to-peer and victim- cache architectures. By leveraging these ideas, Sirocco natively supports several media types, including RAM, flash, disk, and archival storage, with automatic migration between levels. Sirocco also includes storage interfaces and support that are more advanced than typical block storage. Sirocco enables clients to efficiently use key-value storage or block-based storage with the same interface. It also provides several levels of transactional data updatesmore » within a single storage command, including full ACID-compliant updates. This transaction support extends to updating several objects within a single transaction. Further support is provided for con- currency control, enabling greater performance for workloads while providing safe concurrent modification. By pioneering these and other technologies and techniques in the storage system, Sirocco is poised to fulfill a need for a massively scalable, write-optimized storage system for exascale systems. This is version 1.0 of a document reflecting the current and planned state of Sirocco. Further versions of this document will be accessible at http://www.cs.sandia.gov/Scalable_IO/ sirocco .« less
The New Method of Problem Solving in Physics Education by Using SCORM-Compliant Content Package
ERIC Educational Resources Information Center
Gonen, Selahattin; Basaran, Bulent
2008-01-01
In this article, two basic purposes are presented. First, taking effective feedbacks in the electronic learning environment about the learning level of students at the problem solving which are told in physics lessons and laboratories. Second, providing a possibility for students to repeat the subjects and solved problems by watching and…
Verification of a New NOAA/NSIDC Passive Microwave Sea-Ice Concentration Climate Record
NASA Technical Reports Server (NTRS)
Meier, Walter N.; Peng, Ge; Scott, Donna J.; Savoie, Matt H.
2014-01-01
A new satellite-based passive microwave sea-ice concentration product developed for the National Oceanic and Atmospheric Administration (NOAA)Climate Data Record (CDR) programme is evaluated via comparison with other passive microwave-derived estimates. The new product leverages two well-established concentration algorithms, known as the NASA Team and Bootstrap, both developed at and produced by the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC). The sea ice estimates compare well with similar GSFC products while also fulfilling all NOAA CDR initial operation capability (IOC) requirements, including (1) self describing file format, (2) ISO 19115-2 compliant collection-level metadata,(3) Climate and Forecast (CF) compliant file-level metadata, (4) grid-cell level metadata (data quality fields), (5) fully automated and reproducible processing and (6) open online access to full documentation with version control, including source code and an algorithm theoretical basic document. The primary limitations of the GSFC products are lack of metadata and use of untracked manual corrections to the output fields. Smaller differences occur from minor variations in processing methods by the National Snow and Ice Data Center (for the CDR fields) and NASA (for the GSFC fields). The CDR concentrations do have some differences from the constituent GSFC concentrations, but trends and variability are not substantially different.
Wood, Lauren E.; Grau, Josefina M.; Smith, Erin N.; Duran, Petra A.; Castellanos, Patricia
2016-01-01
Objectives It is imperative that individual differences in the cultural contexts of adolescent mothers, whose parenting is often linked to poor child outcomes, be better understood, especially amongst Puerto Rican-origin mothers who experience high rates of poverty. Behaviors that mothers use to elicit compliance from their children are important to investigate, because children’s ability to engage in regulated, compliant behavior has long term consequences for their adjustment. This study tested whether mothers’ orientation to both American and Latino cultures influenced the associations between such maternal behaviors and compliant and defiant child behaviors. Method The sample included 123 young, Puerto Rican-origin mothers and their 24-month old toddlers. Behaviors coded from a toy clean-up task measured maternal guidance and control and child compliance and defiance, and acculturation and enculturation were measured with a self-report questionnaire. Results Maternal guidance predicted more child compliance, with no significant variations by cultural orientation; however, mothers who were more enculturated had children who were more compliant. As predicted, mothers’ more frequent use of control was related to more child defiance for mothers reporting high levels of acculturation, and not for less acculturated mothers. Conclusions Findings support the hypothesis that individual differences in cultural orientation influence variations in associations between certain maternal and child behaviors. PMID:27454887
Standard requirements for GCP-compliant data management in multinational clinical trials.
Ohmann, Christian; Kuchinke, Wolfgang; Canham, Steve; Lauritsen, Jens; Salas, Nader; Schade-Brittinger, Carmen; Wittenberg, Michael; McPherson, Gladys; McCourt, John; Gueyffier, Francois; Lorimer, Andrea; Torres, Ferràn
2011-03-22
A recent survey has shown that data management in clinical trials performed by academic trial units still faces many difficulties (e.g. heterogeneity of software products, deficits in quality management, limited human and financial resources and the complexity of running a local computer centre). Unfortunately, no specific, practical and open standard for both GCP-compliant data management and the underlying IT-infrastructure is available to improve the situation. For that reason the "Working Group on Data Centres" of the European Clinical Research Infrastructures Network (ECRIN) has developed a standard specifying the requirements for high quality GCP-compliant data management in multinational clinical trials. International, European and national regulations and guidelines relevant to GCP, data security and IT infrastructures, as well as ECRIN documents produced previously, were evaluated to provide a starting point for the development of standard requirements. The requirements were produced by expert consensus of the ECRIN Working group on Data Centres, using a structured and standardised process. The requirements were divided into two main parts: an IT part covering standards for the underlying IT infrastructure and computer systems in general, and a Data Management (DM) part covering requirements for data management applications in clinical trials. The standard developed includes 115 IT requirements, split into 15 separate sections, 107 DM requirements (in 12 sections) and 13 other requirements (2 sections). Sections IT01 to IT05 deal with the basic IT infrastructure while IT06 and IT07 cover validation and local software development. IT08 to IT015 concern the aspects of IT systems that directly support clinical trial management. Sections DM01 to DM03 cover the implementation of a specific clinical data management application, i.e. for a specific trial, whilst DM04 to DM12 address the data management of trials across the unit. Section IN01 is dedicated to international aspects and ST01 to the competence of a trials unit's staff. The standard is intended to provide an open and widely used set of requirements for GCP-compliant data management, particularly in academic trial units. It is the intention that ECRIN will use these requirements as the basis for the certification of ECRIN data centres.
Long term telemedicine study of compliance in paranoid schizophrenia.
Krzystanek, Marek; Krzeszowski, Dariusz; Jagoda, Karolina; Krysta, Krzysztof
2015-09-01
Low compliance is one of the crucial problems of contemporary psychiatry. Relapses, deterioration of cognitive functioning, negative symptoms, neuroleptic resistance are the examples of many consequences of noncompliance in schizophrenia The study was designed to assess the compliance in the 200 patients diagnosed with paranoid schizophrenia, all in the state of symptomatic remission and on the stable neuroleptic treatment. The compliance was assessed using a telepsychiatric system, sending reminders: 1 hour before the planned dose to remind them that drug intake is approaching, and at the moment of intake to check if they took the drug. The confirmed drug intakes were counted by the telepsychiatric system. 158 patients completed the study period. The compliance in the first month of the treatment was 44.6% and decreased over the rest of the period to the level of 33.4%. 50% of the schizophrenic patients were compliant at a level lower than 37%. This group was considered the low compliance group, and in this group the compliance increased after 6 months from 9.3% to 10.3% (p<0.0001). The compliance in the group of schizophrenic patients in remission is very low. The telemedicine system improves the compliance in the patients with the worst compliance.
Caudron, Jean Michel; Schiavetti, Benedetta; Pouget, Corinne; Tsoumanis, Achilleas; Meessen, Bruno; Ravinetto, Raffaella
2018-01-01
Introduction The rapid globalisation of the pharmaceutical production and distribution has not been supported by harmonisation of regulatory systems worldwide. Thus, the supply systems in low-income and middle-income countries (LMICs) remain exposed to the risk of poor-quality medicines. To contribute to estimating this risk in the private sector in LMICs, we assessed the quality assurance system of a convenient sample of local private pharmaceutical distributors. Methods This descriptive study uses secondary data derived from the audits conducted by the QUAMED group at 60 local private pharmaceutical distributors in 13 LMICs. We assessed the distributors’ compliance with good distribution practices (GDP), general quality requirements (GQR) and cold chain management (CCM), based on an evaluation tool inspired by the WHO guidelines ’Model Quality Assurance System (MQAS) for procurement agencies'. Descriptive statistics describe the compliance for the whole sample, for distributors in sub-Saharan Africa (SSA) versus those in non-SSA, and for those in low-income countries (LICs) versus middle-income countries (MICs). Results Local private pharmaceutical distributors in our sample were non-compliant, very low-compliant or low-compliant for GQR (70%), GDP (60%) and CCM (41%). Only 7/60 showed good to full compliance for at least two criteria. Observed compliance varies by geographical region and by income group: maximum values are higher in non-SSA versus SSA and in MICs versus LICs, while minimum values are the same across different groups. Conclusion The poor compliance with WHO quality standards observed in our sample indicates a concrete risk that patients in LMICs are exposed to poor-quality or degraded medicines. Significant investments are needed to strengthen the regulatory supervision, including on private pharmaceutical distributors. An adapted standardised evaluation tool inspired by the WHO MQAS would be helpful for self-evaluation, audit and inspection purposes. PMID:29915671
Direct design of an energy landscape with bistable DNA origami mechanisms.
Zhou, Lifeng; Marras, Alexander E; Su, Hai-Jun; Castro, Carlos E
2015-03-11
Structural DNA nanotechnology provides a feasible technique for the design and fabrication of complex geometries even exhibiting controllable dynamic behavior. Recently we have demonstrated the possibility of implementing macroscopic engineering design approaches to construct DNA origami mechanisms (DOM) with programmable motion and tunable flexibility. Here, we implement the design of compliant DNA origami mechanisms to extend from prescribing motion to prescribing an energy landscape. Compliant mechanisms facilitate motion via deformation of components with tunable stiffness resulting in well-defined mechanical energy stored in the structure. We design, fabricate, and characterize a DNA origami nanostructure with an energy landscape defined by two stable states (local energy minima) separated by a designed energy barrier. This nanostructure is a four-bar bistable mechanism with two undeformed states. Traversing between those states requires deformation, and hence mechanical energy storage, in a compliant arm of the linkage. The energy barrier for switching between two states was obtained from the conformational distribution based on a Boltzmann probability function and closely follows a predictive mechanical model. Furthermore, we demonstrated the ability to actuate the mechanism into one stable state via additional DNA inputs and then release the actuation via DNA strand displacement. This controllable multistate system establishes a foundation for direct design of energy landscapes that regulate conformational dynamics similar to biomolecular complexes.
Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies
Harris, J P; Capadona, J R; Miller, R H; Healy, B C; Shanmuganathan, K; Rowan, S J; Weder, C; Tyler, D J
2012-01-01
The hypothesis is that mechanical mismatch between brain tissue and microelectrodes influences the inflammatory response. Our unique, mechanically-adaptive polymer nanocomposite enabled this study within the cerebral cortex of rats. The initial tensile storage modulus of 5 GPa decreases to 12 MPa within 15 minutes under physiological conditions. The response to the nanocomposite was compared to surface-matched, stiffer implants of traditional wires (411 GPa) coated with the identical polymer substrate and implanted on the contralateral side. Both implants were tethered. Fluorescent immunohistochemistry labeling examined neurons, intermediate filaments, macrophages, microglia, and proteoglycans. We demonstrate, for the first time, a system that decouples the mechanical and surface chemistry components of the neural response. The neuronal nuclei density within 100 μm of the device at four weeks post implantation was greater for the compliant nanocomposite compared to the stiff wire. At eight weeks post implantation, the neuronal nuclei density around the nanocomposite was maintained, but the density around the wire recovered to match the nanocomposite. The glial scar response to the compliant nanocomposite was less vigorous than to the stiffer wire. The results suggest that mechanically associated factors such as proteoglycans and intermediate filaments are important modulators of the response of the compliant nanocomposite. PMID:22049097
A novel compact compliant actuator design for rehabilitation robots.
Yu, Haoyong; Huang, Sunan; Thakor, Nitish V; Chen, Gong; Toh, Siew-Lok; Sta Cruz, Manolo; Ghorbel, Yassine; Zhu, Chi
2013-06-01
Rehabilitation robots have direct physical interaction with human body. Ideally, actuators for rehabilitation robots should be compliant, force controllable, and back drivable due to safety and control considerations. Various designs of Series Elastic Actuators (SEA) have been developed for these applications. However, current SEA designs face a common performance limitation due to the compromise on the spring stiffness selection. This paper presents a novel compact compliant force control actuator design for portable rehabilitation robots to overcome the performance limitations in current SEAs. Our design consists of a servomotor, a ball screw, a torsional spring between the motor and the ball screw, and a set of translational springs between the ball screw nut and the external load. The soft translational springs are used to handle the low force operation and reduce output impedance, stiction, and external shock load. The torsional spring, being in the high speed range, has high effective stiffness and improves the system bandwidth in large force operation when the translational springs are fully compressed. This design is also more compact due to the smaller size of the springs. We explain the construction and the working principle of our new design, followed by the dynamic modeling and analysis of the actuator. We also show the preliminary testing results of a prototype actuator designed for a lower limb exoskeleton for gait rehabilitation.
Project Integration Architecture
NASA Technical Reports Server (NTRS)
Jones, William Henry
2008-01-01
The Project Integration Architecture (PIA) is a distributed, object-oriented, conceptual, software framework for the generation, organization, publication, integration, and consumption of all information involved in any complex technological process in a manner that is intelligible to both computers and humans. In the development of PIA, it was recognized that in order to provide a single computational environment in which all information associated with any given complex technological process could be viewed, reviewed, manipulated, and shared, it is necessary to formulate all the elements of such a process on the most fundamental level. In this formulation, any such element is regarded as being composed of any or all of three parts: input information, some transformation of that input information, and some useful output information. Another fundamental principle of PIA is the assumption that no consumer of information, whether human or computer, can be assumed to have any useful foreknowledge of an element presented to it. Consequently, a PIA-compliant computing system is required to be ready to respond to any questions, posed by the consumer, concerning the nature of the proffered element. In colloquial terms, a PIA-compliant system must be prepared to provide all the information needed to place the element in context. To satisfy this requirement, PIA extends the previously established object-oriented- programming concept of self-revelation and applies it on a grand scale. To enable pervasive use of self-revelation, PIA exploits another previously established object-oriented-programming concept - that of semantic infusion through class derivation. By means of self-revelation and semantic infusion through class derivation, a consumer of information can inquire about the contents of all information entities (e.g., databases and software) and can interact appropriately with those entities. Other key features of PIA are listed.
Przybylo, Jennifer A; Wang, Ange; Loftus, Pooja; Evans, Kambria H; Chu, Isabella; Shieh, Lisa
2014-09-01
Though current hospital paging systems are neither efficient (callbacks disrupt workflow), nor secure (pagers are not Health Insurance Portability and Accountability Act [HIPAA]-compliant), they are routinely used to communicate patient information. Smartphone-based text messaging is a potentially more convenient and efficient mobile alternative; however, commercial cellular networks are also not secure. To determine if augmenting one-way pagers with Medigram, a secure, HIPAA-compliant group messaging (HCGM) application for smartphones, could improve hospital team communication. Eight-week prospective, cluster-randomized, controlled trial Stanford Hospital Three inpatient medicine teams used the HCGM application in addition to paging, while two inpatient medicine teams used paging only for intra-team communication. Baseline and post-study surveys were collected from 22 control and 41 HCGM team members. When compared with paging, HCGM was rated significantly (P < 0.05) more effective in: (1) allowing users to communicate thoughts clearly (P = 0.010) and efficiently (P = 0.009) and (2) integrating into workflow during rounds (P = 0.018) and patient discharge (P = 0.012). Overall satisfaction with HCGM was significantly higher (P = 0.003). 85% of HCGM team respondents said they would recommend using an HCGM system on the wards. Smartphone-based, HIPAA-compliant group messaging applications improve provider perception of in-hospital communication, while providing the information security that paging and commercial cellular networks do not. © 2014 The Authors Journal of Hospital Medicine published by Wiley Periodicals, Inc. on behalf of Society of Hospital Medicine.
Instrumented Compliant Wrist with Proximity and Contact Sensing for Close Robot Interaction Control.
Laferrière, Pascal; Payeur, Pierre
2017-06-14
Compliance has been exploited in various forms in robotic systems to allow rigid mechanisms to come into contact with fragile objects, or with complex shapes that cannot be accurately modeled. Force feedback control has been the classical approach for providing compliance in robotic systems. However, by integrating other forms of instrumentation with compliance into a single device, it is possible to extend close monitoring of nearby objects before and after contact occurs. As a result, safer and smoother robot control can be achieved both while approaching and while touching surfaces. This paper presents the design and extensive experimental evaluation of a versatile, lightweight, and low-cost instrumented compliant wrist mechanism which can be mounted on any rigid robotic manipulator in order to introduce a layer of compliance while providing the controller with extra sensing signals during close interaction with an object's surface. Arrays of embedded range sensors provide real-time measurements on the position and orientation of surfaces, either located in proximity or in contact with the robot's end-effector, which permits close guidance of its operation. Calibration procedures are formulated to overcome inter-sensor variability and achieve the highest available resolution. A versatile solution is created by embedding all signal processing, while wireless transmission connects the device to any industrial robot's controller to support path control. Experimental work demonstrates the device's physical compliance as well as the stability and accuracy of the device outputs. Primary applications of the proposed instrumented compliant wrist include smooth surface following in manufacturing, inspection, and safe human-robot interaction.
Self-assembled three dimensional network designs for soft electronics
Jang, Kyung-In; Li, Kan; Chung, Ha Uk; Xu, Sheng; Jung, Han Na; Yang, Yiyuan; Kwak, Jean Won; Jung, Han Hee; Song, Juwon; Yang, Ce; Wang, Ao; Liu, Zhuangjian; Lee, Jong Yoon; Kim, Bong Hoon; Kim, Jae-Hwan; Lee, Jungyup; Yu, Yongjoon; Kim, Bum Jun; Jang, Hokyung; Yu, Ki Jun; Kim, Jeonghyun; Lee, Jung Woo; Jeong, Jae-Woong; Song, Young Min; Huang, Yonggang; Zhang, Yihui; Rogers, John A.
2017-01-01
Low modulus, compliant systems of sensors, circuits and radios designed to intimately interface with the soft tissues of the human body are of growing interest, due to their emerging applications in continuous, clinical-quality health monitors and advanced, bioelectronic therapeutics. Although recent research establishes various materials and mechanics concepts for such technologies, all existing approaches involve simple, two-dimensional (2D) layouts in the constituent micro-components and interconnects. Here we introduce concepts in three-dimensional (3D) architectures that bypass important engineering constraints and performance limitations set by traditional, 2D designs. Specifically, open-mesh, 3D interconnect networks of helical microcoils formed by deterministic compressive buckling establish the basis for systems that can offer exceptional low modulus, elastic mechanics, in compact geometries, with active components and sophisticated levels of functionality. Coupled mechanical and electrical design approaches enable layout optimization, assembly processes and encapsulation schemes to yield 3D configurations that satisfy requirements in demanding, complex systems, such as wireless, skin-compatible electronic sensors. PMID:28635956
Self-assembled three dimensional network designs for soft electronics
NASA Astrophysics Data System (ADS)
Jang, Kyung-In; Li, Kan; Chung, Ha Uk; Xu, Sheng; Jung, Han Na; Yang, Yiyuan; Kwak, Jean Won; Jung, Han Hee; Song, Juwon; Yang, Ce; Wang, Ao; Liu, Zhuangjian; Lee, Jong Yoon; Kim, Bong Hoon; Kim, Jae-Hwan; Lee, Jungyup; Yu, Yongjoon; Kim, Bum Jun; Jang, Hokyung; Yu, Ki Jun; Kim, Jeonghyun; Lee, Jung Woo; Jeong, Jae-Woong; Song, Young Min; Huang, Yonggang; Zhang, Yihui; Rogers, John A.
2017-06-01
Low modulus, compliant systems of sensors, circuits and radios designed to intimately interface with the soft tissues of the human body are of growing interest, due to their emerging applications in continuous, clinical-quality health monitors and advanced, bioelectronic therapeutics. Although recent research establishes various materials and mechanics concepts for such technologies, all existing approaches involve simple, two-dimensional (2D) layouts in the constituent micro-components and interconnects. Here we introduce concepts in three-dimensional (3D) architectures that bypass important engineering constraints and performance limitations set by traditional, 2D designs. Specifically, open-mesh, 3D interconnect networks of helical microcoils formed by deterministic compressive buckling establish the basis for systems that can offer exceptional low modulus, elastic mechanics, in compact geometries, with active components and sophisticated levels of functionality. Coupled mechanical and electrical design approaches enable layout optimization, assembly processes and encapsulation schemes to yield 3D configurations that satisfy requirements in demanding, complex systems, such as wireless, skin-compatible electronic sensors.
Linking climate change to water provision: greywater treatment by constructed wetlands
NASA Astrophysics Data System (ADS)
Qomariyah, S.; Ramelan, AH; Setyono, P.; Sobriyah
2018-03-01
Climate change has been felt to take place in Indonesia, causing the temperature to increase, additional drought with more moisture evaporates from rivers, lakes, and other bodies of water, and intense rainfall in a shorter rainy season. One of the major concerns is the risk of severe drought leading to water shortages. It will affect water supply and agriculture yields. As a country extremely vulnerable to the climate change, Indonesia must adapt to the serious environmental issues. This paper aims to offer an effort of water provision by recycling and reusing of greywater applying constructed wetland systems. The treated greywater is useful as water provision for non-consumptive uses. A recent experiment was conducted on a household yard using a single horizontal subsurface flow type of constructed wetland. The experiments demonstrated that the constructed wetland systems reduced effectively the pollutants of TSS, BOD, COD, and detergent to the level that are compliant with regulatory standards. The constructed wetland has been established for almost two years however the system still works properly.
Dry compliant seal for phosphoric acid fuel cell
Granata, Jr., Samuel J.; Woodle, Boyd M.
1990-01-01
A dry compliant overlapping seal for a phosphoric acid fuel cell preformed f non-compliant Teflon to make an anode seal frame that encircles an anode assembly, a cathode seal frame that encircles a cathode assembly and a compliant seal frame made of expanded Teflon, generally encircling a matrix assembly. Each frame has a thickness selected to accommodate various tolerances of the fuel cell elements and are either bonded to one of the other frames or to a bipolar or end plate. One of the non-compliant frames is wider than the other frames forming an overlap of the matrix over the wider seal frame, which cooperates with electrolyte permeating the matrix to form a wet seal within the fuel cell that prevents process gases from intermixing at the periphery of the fuel cell and a dry seal surrounding the cell to keep electrolyte from the periphery thereof. The frames may be made in one piece, in L-shaped portions or in strips and have an outer perimeter which registers with the outer perimeter of bipolar or end plates to form surfaces upon which flanges of pan shaped, gas manifolds can be sealed.
Parrish, Clyde F
2003-12-01
A series of workshops were sponsored by the Physical Science Division of NASA's Office of Biological and Physical Research to address operational gravity-compliant in-situ resource utilization and life support techologies. Workshop participants explored a Mars simulation study on Devon Island, Canada; the processing of carbon dioxide in regenerative life support systems; space tourism; rocket technology; plant growth research for closed ecological systems; and propellant extraction of planetary regoliths.
Environmentally Compliant Thermoplastic Powder Coating, Phase 1
1992-10-07
TPC flame sprayed application equipment and ethylene acrylic acid (EAA) and ethylene methacrylic acid (EMAA) copolymers thermoplastic powder...have worked closely with Dow Chemical to develop and optimize their systems using Dow "Envelon" ethylene acrylic acid (EAA) thermoplastic copolymers...provide on/off control. CFS recommends the use of Dow "Envelon" ethylene acrylic acid (EAA) copolymer thermoplastic powder with this unit. The CFS system
Learning Portfolio Analysis and Mining for SCORM Compliant Environment
ERIC Educational Resources Information Center
Su, Jun-Ming; Tseng, Shian-Shyong; Wang, Wei; Weng, Jui-Feng; Yang, Jin Tan David; Tsai, Wen-Nung
2006-01-01
With vigorous development of the Internet, e-learning system has become more and more popular. Sharable Content Object Reference Model (SCORM) 2004 provides the Sequencing and Navigation (SN) Specification to define the course sequencing behavior, control the sequencing, selecting and delivering of course, and organize the content into a…
Impact of EMP on Air Operations
pulse while in flight. With a requirement to be compliant with this standard for all critical weapon systems, the C -17 remains untested. The significant...EMP event that would threaten an inflight C -17, there was not enough evidence to force a change to the current EMP testing and hardening schedule.
78 FR 40478 - Privacy Act of 1974; Notice of an Updated System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-05
... of MyUSA's programmatic interfaces, such as notifications, tasks, or events; (3) a history of third... Technology standards and information in the database is encrypted. Records are safeguarded in accordance with... algorithms and firewalls are compliant with National Institute of Standards and Technology standards...
Compliant tactile sensor that delivers a force vector
NASA Technical Reports Server (NTRS)
Torres-Jara, Eduardo (Inventor)
2010-01-01
Tactile Sensor. The sensor includes a compliant convex surface disposed above a sensor array, the sensor array adapted to respond to deformation of the convex surface to generate a signal related to an applied force vector. The applied force vector has three components to establish the direction and magnitude of an applied force. The compliant convex surface defines a dome with a hollow interior and has a linear relation between displacement and load including a magnet disposed substantially at the center of the dome above a sensor array that responds to magnetic field intensity.
Compliant Electrode and Composite Material for Piezoelectric Wind and Mechanical Energy Conversions
NASA Technical Reports Server (NTRS)
Chen, Bin (Inventor)
2015-01-01
A thin film device for harvesting energy from wind. The thin film device includes one or more layers of a compliant piezoelectric material formed from a composite of a polymer and an inorganic material, such as a ceramic. Electrodes are disposed on a first side and a second side of the piezoelectric material. The electrodes are formed from a compliant material, such as carbon nanotubes or graphene. The thin film device exhibits improved resistance to structural fatigue upon application of large strains and repeated cyclic loadings.
Approach for Structurally Clearing an Adaptive Compliant Trailing Edge Flap for Flight
NASA Technical Reports Server (NTRS)
Miller, Eric J.; Lokos, William A.; Cruz, Josue; Crampton, Glen; Stephens, Craig A.; Kota, Sridhar; Ervin, Gregory; Flick, Pete
2015-01-01
The Adaptive Compliant Trailing Edge (ACTE) flap was flown on the NASA Gulfstream GIII test bed at the NASA Armstrong Flight Research Center. This smoothly curving flap replaced the existing Fowler flaps creating a seamless control surface. This compliant structure, developed by FlexSys Inc. in partnership with Air Force Research Laboratory, supported NASA objectives for airframe structural noise reduction, aerodynamic efficiency, and wing weight reduction through gust load alleviation. A thorough structures airworthiness approach was developed to move this project safely to flight.
Spacecraft Onboard Interface Services: Current Status and Roadmap
NASA Astrophysics Data System (ADS)
Prochazka, Marek; Lopez Trescastro, Jorge; Krueger, Sabine
2016-08-01
Spacecraft Onboard Interface Services (SOIS) is a set of CCSDS standards defining communication stack services to interact with hardware equipment onboard spacecraft. In 2014 ESA kicked off three parallel activities to critically review the SOIS standards, use legacy spacecraft flight software (FSW), make it compliant to a preselected subset of SOIS standards and make performance and architecture assessment. As a part of the three parallel activities, led by Airbus DS Toulouse, OHB Bremen and Thales Alenia Space Cannes respectively, it was to provide feedback back to ESA and CCSDS and also to propose a roadmap of transition towards an operational FSW system fully compliant to applicable SOIS standards. The objective of the paper is twofold: Firstly it is to summarise main results of the three parallel activities and secondly, based on the results, to propose a roadmap for the future.
NASA Astrophysics Data System (ADS)
Li, Chuanwei; Kong, Yingxiao; Jiang, Wenchong; Wang, Zhiyong; Li, Linan; Wang, Shibin
2017-06-01
The wrinkling of a silicon monoxide thin film on a compliant poly(dimethylsiloxane) (PDMS) substrate structure was experimentally investigated in this study. The self-expansion effect of PDMS during film deposition was utilized to impose a pretensile strain on the structure through a specially made fixture. A laser scanning confocal microscope (LSCM) system with an in situ heating stage was employed for the real-time measurement. The Young’s modulus of the silicon monoxide thin film as well as the PDMS substrate was measured on the basis of the elasticity theory. Moreover, the effects of temperature variations on geometric parameters in the postbuckling state, such as wavelength and amplitude, were analyzed. It was proved that wavelength is relatively immune to thermal loads, while amplitude is much more sensitive.
Aerodynamic Flight-Test Results for the Adaptive Compliant Trailing Edge
NASA Technical Reports Server (NTRS)
Cumming, Stephen B.; Smith, Mark S.; Ali, Aliyah N.; Bui, Trong T.; Ellsworth, Joel C.; Garcia, Christian A.
2016-01-01
The aerodynamic effects of compliant flaps installed onto a modified Gulfstream III airplane were investigated. Analyses were performed prior to flight to predict the aerodynamic effects of the flap installation. Flight tests were conducted to gather both structural and aerodynamic data. The airplane was instrumented to collect vehicle aerodynamic data and wing pressure data. A leading-edge stagnation detection system was also installed. The data from these flights were analyzed and compared with predictions. The predictive tools compared well with flight data for small flap deflections, but differences between predictions and flight estimates were greater at larger deflections. This paper describes the methods used to examine the aerodynamics data from the flight tests and provides a discussion of the flight-test results in the areas of vehicle aerodynamics, wing sectional pressure coefficient profiles, and air data.
Approach for Structurally Clearing an Adaptive Compliant Trailing Edge Flap for Flight
NASA Technical Reports Server (NTRS)
Miller, Eric J.; Lokos, William A.; Cruz, Josue; Crampton, Glen; Stephens, Craig A.; Kota, Sridhar; Ervin, Gregory; Flick, Pete
2015-01-01
The Adaptive Compliant Trailing Edge (ACTE) flap was flown on the National Aeronautics and Space Administration (NASA) Gulfstream GIII testbed at the NASA Armstrong Flight Research Center. This smoothly curving flap replaced the existing Fowler flaps creating a seamless control surface. This compliant structure, developed by FlexSys Inc. in partnership with the Air Force Research Laboratory, supported NASA objectives for airframe structural noise reduction, aerodynamic efficiency, and wing weight reduction through gust load alleviation. A thorough structures airworthiness approach was developed to move this project safely to flight. A combination of industry and NASA standard practice require various structural analyses, ground testing, and health monitoring techniques for showing an airworthy structure. This paper provides an overview of compliant structures design, the structural ground testing leading up to flight, and the flight envelope expansion and monitoring strategy. Flight data will be presented, and lessons learned along the way will be highlighted.
Yao, Cheng-Hsiang; Lin, Kun-Ju; Weng, Chi-Chang; Hsiao, Ing-Tsung; Ting, Yi-Shu; Yen, Tzu-Chen; Jan, Tong-Rong; Skovronsky, Daniel; Kung, Mei-Ping; Wey, Shiaw-Pyng
2010-12-01
We report herein the Good Manufacturing Practice (GMP)-compliant automated synthesis of (18)F-labeled styrylpyridine, AV-45 (Florbetapir), a novel tracer for positron emission tomography (PET) imaging of beta-amyloid (Abeta) plaques in the brain of Alzheimer's disease patients. [(18)F]AV-45 was prepared in 105 min using a tosylate precursor with Sumitomo modules for radiosynthesis under GMP-compliant conditions. The overall yield was 25.4+/-7.7% with a final radiochemical purity of 95.3+/-2.2% (n=19). The specific activity of [(18)F]AV-45 reached as high as 470+/-135 TBq/mmol (n=19). The present studies show that [(18)F]AV-45 can be manufactured under GMP-compliant conditions and could be widely available for routine clinical use. Copyright 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Dumoulin, J.; Averty, R.
2012-04-01
One of the objectives of ISTIMES project is to evaluate the potentialities offered by the integration of different electromagnetic techniques able to perform non-invasive diagnostics for surveillance and monitoring of transport infrastructures. Among the EM methods investigated, uncooled infrared camera is a promising technique due to its dissemination potential according to its relative low cost on the market. Infrared thermography, when it is used in quantitative mode (not in laboratory conditions) and not in qualitative mode (vision applied to survey), requires to process in real time thermal radiative corrections on raw data acquired to take into account influences of natural environment evolution with time. But, camera sensor has to be enough smart to apply in real time calibration law and radiometric corrections in a varying atmosphere. So, a complete measurement system was studied and developed with low cost infrared cameras available on the market. In the system developed, infrared camera is coupled with other sensors to feed simplified radiative models running, in real time, on GPU available on small PC. The system studied and developed uses a fast Ethernet camera FLIR A320 [1] coupled with a VAISALA WXT520 [2] weather station and a light GPS unit [3] for positioning and dating. It can be used with other Ethernet infrared cameras (i.e. visible ones) but requires to be able to access measured data at raw level. In the present study, it has been made possible thanks to a specific agreement signed with FLIR Company. The prototype system studied and developed is implemented on low cost small computer that integrates a GPU card to allow real time parallel computing [4] of simplified radiometric [5] heat balance using information measured with the weather station. An HMI was developed under Linux using OpenSource and complementary pieces of software developed at IFSTTAR. This new HMI called "IrLaW" has various functionalities that let it compliant to be use in real site for long term monitoring. It can be remotely controlled in wire or wireless communication mode depending on what is the context of measurement and the degree of accessibility to the system when it is running on real site. To complete and conclude, thanks to the development of a high level library, but also to the deployment of a daemon, our developed measurement system was tuned to be compatible with OGC standards. Complementary functionalities were also developed to allow the system to self declare to 52North. For that, a specific plugin was developed to be inserted previously at 52North level. Finally, data are also accessible by tasking the system when required, fort instance by using the web portal developed in the ISTIMES Framework. ACKNOWLEDGEMENT - The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under Grant Agreement n° 225663.
Rich media streaming for just-in-time training of first responders
NASA Astrophysics Data System (ADS)
Bandera, Cesar; Marsico, Michael
2005-05-01
The diversity of first responders and of asymmetric threats precludes the effectiveness of any single training syllabus. Just-in-time training (JITT) addresses this variability, but requires training content to be quickly tailored to the subject (the threat), the learner (the responder), and the infrastructure (the C2 chain from DHS to the responder"s equipment). We present a distributed system for personalized just-in-time training of first responders. The authoring and delivery of interactive rich media and simulations, and the integration of JITT with C2 centers, are demonstrated. Live and archived video, imagery, 2-D and 3-D models, and simulations are autonomously (1) aggregated from object-oriented databases into SCORM-compliant objects, (2) tailored to the individual learner"s training history, preferences, connectivity and computing platform (from workstations to wireless PDAs), (3) conveyed as secure and reliable MPEG-4 compliant streams with data rights management, and (4) rendered as interactive high-definition rich media that promotes knowledge retention and the refinement of learner skills without the need of special hardware. We review the object-oriented implications of SCORM and the higher level profiles of the MPEG-4 standard, and show how JITT can be integrated into - and improve the ROI of - existing training infrastructures, including COTS content authoring tools, LMS/CMS, man-in-the-loop simulators, and legacy content. Lastly, we compare the audiovisual quality of different streaming platforms under varying connectivity conditions.
ERIC Educational Resources Information Center
MacLean, Ian N.
This practicum was designed to improve the level and quality of involvement of foster parents and social workers in the development of timely and compliant foster care plans at a child care agency in Ontario. The writer developed: (1) an agency policy that defined the unique relationship between foster parents and the child welfare agency and…
Non-compliant Actors (NONCAS) Handbook
2010-07-23
general cultural dimensions (see e.g. Hofstede: 1997) may be scrutinised in the context of NC/NONCAS. For example a collectivist oriented society...being; the socio- cultural context; he level of participation and inclusiveness in the political, social, cultural and economic domains; a potential...forces are always strangers to the country where they intervene (especially in cultural terms). Thirdly, resources and means, including manpower and
Vine, Michelle M; Elliott, Susan J; Raine, Kim D
2014-09-01
The purpose of this study was to explore the implementation of the Ontario School Food and Beverage Policy (P/PM 150) from the perspective of secondary-school students. This research, informed by the ANGELO framework, undertook three focus groups with secondary students (n = 20) in 2 school boards representing both high- and low-income neighbourhoods in fall 2012. Focus groups were transcribed verbatim for subsequent analysis. Key themes were generated deductively from the research objectives and inductively as they emerged from transcripts. Perceived impacts of P/PM 150 included high-priced policy-compliant food for sale, lower revenue generation, and food purchased off-campus. Limited designated eating spaces, proximity to external, nonpolicy-compliant food, and time constraints acted as key local level barriers to healthy eating. Pricing strategies are needed to ensure that all students have access to nutritious food, particularly in the context of vulnerable populations. Recognition of the context and culture in which school nutrition policies are being implemented is essential. Future research to explore the role of public health dietitians in school nutrition policy initiatives and how to leverage local resources and stakeholder support in low income, rural and remote populations is needed.
Design and control of compliant tensegrity robots through simulation and hardware validation
Caluwaerts, Ken; Despraz, Jérémie; Işçen, Atıl; Sabelhaus, Andrew P.; Bruce, Jonathan; Schrauwen, Benjamin; SunSpiral, Vytas
2014-01-01
To better understand the role of tensegrity structures in biological systems and their application to robotics, the Dynamic Tensegrity Robotics Lab at NASA Ames Research Center, Moffett Field, CA, USA, has developed and validated two software environments for the analysis, simulation and design of tensegrity robots. These tools, along with new control methodologies and the modular hardware components developed to validate them, are presented as a system for the design of actuated tensegrity structures. As evidenced from their appearance in many biological systems, tensegrity (‘tensile–integrity’) structures have unique physical properties that make them ideal for interaction with uncertain environments. Yet, these characteristics make design and control of bioinspired tensegrity robots extremely challenging. This work presents the progress our tools have made in tackling the design and control challenges of spherical tensegrity structures. We focus on this shape since it lends itself to rolling locomotion. The results of our analyses include multiple novel control approaches for mobility and terrain interaction of spherical tensegrity structures that have been tested in simulation. A hardware prototype of a spherical six-bar tensegrity, the Reservoir Compliant Tensegrity Robot, is used to empirically validate the accuracy of simulation. PMID:24990292
Cable applications in robot compliant devices
NASA Technical Reports Server (NTRS)
Kerley, James J.
1987-01-01
Robotic systems need compliance to connect the robot to the work object. The cable system illustrated offers compliance for mating but can be changed in space to become quite stiff. Thus the same system can do both tasks, even in environments where the work object or robot are moving at different frequencies and different amplitudes. The adjustment can be made in all six degrees of freedom, translated in or rotated in any plane and still make a good contact and control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-03-28
GridAPPS-D is an open-source, open architecture, standards based platform for development of advanced electric power system planning and operations applications. GridAPPS-D provides a documented data abstraction for the application developer enabling creation of applications that can be run in any compliant system or platform. This enables development of applications that are platform vendor independent applications and applications that take advantage of the possibility of data rich and data driven applications based on deployment of smart grid devices and systems.
NASA Technical Reports Server (NTRS)
Shalkhauser, Mary Jo W.; Roche, Rigoberto
2017-01-01
The Space Telecommunications Radio System (STRS) provides a common, consistent framework for software defined radios (SDRs) to abstract the application software from the radio platform hardware. The STRS standard aims to reduce the cost and risk of using complex, configurable and reprogrammable radio systems across NASA missions. To promote the use of the STRS architecture for future NASA advanced exploration missions, NASA Glenn Research Center (GRC) developed an STRS-compliant SDR on a radio platform used by the Advance Exploration System program at the Johnson Space Center (JSC) in their Integrated Power, Avionics, and Software (iPAS) laboratory. The iPAS STRS Radio was implemented on the Reconfigurable, Intelligently-Adaptive Communication System (RIACS) platform, currently being used for radio development at JSC. The platform consists of a Xilinx(Trademark) ML605 Virtex(Trademark)-6 FPGA board, an Analog Devices FMCOMMS1-EBZ RF transceiver board, and an Embedded PC (Axiomtek(Trademark) eBox 620-110-FL) running the Ubuntu 12.4 operating system. The result of this development is a very low cost STRS compliant platform that can be used for waveform developments for multiple applications. The purpose of this document is to describe how to develop a new waveform using the RIACS platform and the Very High Speed Integrated Circuits (VHSIC) Hardware Description Language (VHDL) FPGA wrapper code and the STRS implementation on the Axiomtek processor.
NASA Astrophysics Data System (ADS)
McDonald, Michael C.; Kim, H. K.; Henry, J. R.; Cunningham, I. A.
2012-03-01
The detective quantum efficiency (DQE) is widely accepted as a primary measure of x-ray detector performance in the scientific community. A standard method for measuring the DQE, based on IEC 62220-1, requires the system to have a linear response meaning that the detector output signals are proportional to the incident x-ray exposure. However, many systems have a non-linear response due to characteristics of the detector, or post processing of the detector signals, that cannot be disabled and may involve unknown algorithms considered proprietary by the manufacturer. For these reasons, the DQE has not been considered as a practical candidate for routine quality assurance testing in a clinical setting. In this article we described a method that can be used to measure the DQE of both linear and non-linear systems that employ only linear image processing algorithms. The method was validated on a Cesium Iodide based flat panel system that simultaneously stores a raw (linear) and processed (non-linear) image for each exposure. It was found that the resulting DQE was equivalent to a conventional standards-compliant DQE with measurement precision, and the gray-scale inversion and linear edge enhancement did not affect the DQE result. While not IEC 62220-1 compliant, it may be adequate for QA programs.
Tellurium notebooks-An environment for reproducible dynamical modeling in systems biology.
Medley, J Kyle; Choi, Kiri; König, Matthias; Smith, Lucian; Gu, Stanley; Hellerstein, Joseph; Sealfon, Stuart C; Sauro, Herbert M
2018-06-01
The considerable difficulty encountered in reproducing the results of published dynamical models limits validation, exploration and reuse of this increasingly large biomedical research resource. To address this problem, we have developed Tellurium Notebook, a software system for model authoring, simulation, and teaching that facilitates building reproducible dynamical models and reusing models by 1) providing a notebook environment which allows models, Python code, and narrative to be intermixed, 2) supporting the COMBINE archive format during model development for capturing model information in an exchangeable format and 3) enabling users to easily simulate and edit public COMBINE-compliant models from public repositories to facilitate studying model dynamics, variants and test cases. Tellurium Notebook, a Python-based Jupyter-like environment, is designed to seamlessly inter-operate with these community standards by automating conversion between COMBINE standards formulations and corresponding in-line, human-readable representations. Thus, Tellurium brings to systems biology the strategy used by other literate notebook systems such as Mathematica. These capabilities allow users to edit every aspect of the standards-compliant models and simulations, run the simulations in-line, and re-export to standard formats. We provide several use cases illustrating the advantages of our approach and how it allows development and reuse of models without requiring technical knowledge of standards. Adoption of Tellurium should accelerate model development, reproducibility and reuse.
Compliant tactile sensor for generating a signal related to an applied force
NASA Technical Reports Server (NTRS)
Torres-Jara, Eduardo (Inventor)
2012-01-01
Tactile sensor. The sensor includes a compliant convex surface disposed above a sensor array, the sensor array adapted to respond to deformation of the convex surface to generate a signal related to an applied force vector.
76 FR 17429 - Buy American Exceptions Under the American Recovery and Reinvestment Act of 2009
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-29
... closets that comply with the Americans with Disabilities Act (ADA-compliant water closets) at the Orness... goods (ADA-compliant water closets) are not produced in the U.S. in sufficient and reasonably available...
Pirro, Valentina; Girolami, Flavia; Spalenza, Veronica; Gardini, Giulia; Badino, Paola; Nebbia, Carlo
2015-01-01
A chemometric class modelling strategy (unequal dispersed classes - UNEQ) was applied for the first time as a possible screening method to monitor the abuse of growth promoters in veal calves. Five serum biomarkers, known to reflect the exposure to classes of compounds illegally used as growth promoters, were determined from 50 untreated animals in order to design a model of controls, representing veal calves reared under good, safe and highly standardised breeding conditions. The class modelling was applied to 421 commercially bred veal calves to separate them into 'compliant' and 'non-compliant' with respect to the modelled controls. Part of the non-compliant animals underwent further histological and chemical examinations to confirm the presence of either alterations in target tissues or traces of illegal substances commonly administered for growth-promoting purposes. Overall, the congruence between the histological or chemical methods and the UNEQ non-compliant outcomes was approximately 58%, likely underestimated due to the blindness nature of this examination. Further research is needed to confirm the validity of the UNEQ model in terms of sensitivity in recognising untreated animals as compliant to the controls, and specificity in revealing deviations from ideal breeding conditions, for example due to the abuse of growth promoters.
Dependence of residual displacements on the width and depth of compliant fault zones: a 3D study
NASA Astrophysics Data System (ADS)
Kang, J.; Duan, B.
2011-12-01
Compliant fault zones have been detected along active faults by seismic investigations (trapped waves and travel time analysis) and InSAR observations. However, the width and depth extent of compliant fault zones are still under debate in the community. Numerical models of dynamic rupture build a bridge between theories and the geological and geophysical observations. Theoretical 2D plane-strain studies of elastic and inelastic response of compliant fault zones to nearby earthquake have been conducted by Duan [2010] and Duan et al [2010]. In this study, we further extend the experiments to 3D with a focus on elastic response. We are specifically interested in how residual displacements depend on the structure and properties of complaint fault zones, in particular on the width and depth extent. We conduct numerical experiments on various types of fault-zone models, including fault zones with a constant width along depth, with decreasing widths along depth, and with Hanning taper profiles of velocity reduction. . Our preliminary results suggest 1) the width of anomalous horizontal residual displacement is only indicative of the width of a fault zone near the surface, and 2) the vertical residual displacement contains information of the depth extent of compliant fault zones.
Sripathi, Vangipuram Canchi; Kumar, Ramarathnam Krishna; Balakrishnan, Komarakshi R
2004-03-01
This study aims to find the fundamental differences in the mechanism of opening and closing of a normal aortic valve and a valve with a stiff root, using a dynamic finite element model. A dynamic, finite element model with time varying pressure was used in this study. Shell elements with linear elastic properties for the leaflet and root were used. Two different cases were analyzed: (1) normal leaflets inside a compliant root, and (2) normal leaflets inside a stiff root. A compliant aortic root contributes substantially to the smooth and symmetrical leaflet opening with minimal gradients. In contrast, the leaflet opening inside a stiff root is delayed, asymmetric, and wrinkled. However, this wrinkling is not associated with increased leaflet stresses. In compliant roots, the effective valve orifice area can substantially increase because of increased root pressure and transvalvular gradients. In stiff roots this effect is strikingly absent. A compliant aortic root contributes substantially to smooth and symmetrical leaflet opening with minimal gradients. The compliance also contributes much to the ability of the normal aortic valve to increase its effective valve orifice in response to physiologic demands of exercise. This effect is strikingly absent in stiff roots.
Fabrication Process of Silicone-based Dielectric Elastomer Actuators
Rosset, Samuel; Araromi, Oluwaseun A.; Schlatter, Samuel; Shea, Herbert R.
2016-01-01
This contribution demonstrates the fabrication process of dielectric elastomer transducers (DETs). DETs are stretchable capacitors consisting of an elastomeric dielectric membrane sandwiched between two compliant electrodes. The large actuation strains of these transducers when used as actuators (over 300% area strain) and their soft and compliant nature has been exploited for a wide range of applications, including electrically tunable optics, haptic feedback devices, wave-energy harvesting, deformable cell-culture devices, compliant grippers, and propulsion of a bio-inspired fish-like airship. In most cases, DETs are made with a commercial proprietary acrylic elastomer and with hand-applied electrodes of carbon powder or carbon grease. This combination leads to non-reproducible and slow actuators exhibiting viscoelastic creep and a short lifetime. We present here a complete process flow for the reproducible fabrication of DETs based on thin elastomeric silicone films, including casting of thin silicone membranes, membrane release and prestretching, patterning of robust compliant electrodes, assembly and testing. The membranes are cast on flexible polyethylene terephthalate (PET) substrates coated with a water-soluble sacrificial layer for ease of release. The electrodes consist of carbon black particles dispersed into a silicone matrix and patterned using a stamping technique, which leads to precisely-defined compliant electrodes that present a high adhesion to the dielectric membrane on which they are applied. PMID:26863283
Information System through ANIS at CeSAM
NASA Astrophysics Data System (ADS)
Moreau, C.; Agneray, F.; Gimenez, S.
2015-09-01
ANIS (AstroNomical Information System) is a web generic tool developed at CeSAM to facilitate and standardize the implementation of astronomical data of various kinds through private and/or public dedicated Information Systems. The architecture of ANIS is composed of a database server which contains the project data, a web user interface template which provides high level services (search, extract and display imaging and spectroscopic data using a combination of criteria, an object list, a sql query module or a cone search interfaces), a framework composed of several packages, and a metadata database managed by a web administration entity. The process to implement a new ANIS instance at CeSAM is easy and fast : the scientific project has to submit data or a data secure access, the CeSAM team installs the new instance (web interface template and the metadata database), and the project administrator can configure the instance with the web ANIS-administration entity. Currently, the CeSAM offers through ANIS a web access to VO compliant Information Systems for different projects (HeDaM, HST-COSMOS, CFHTLS-ZPhots, ExoDAT,...).
On Campus Web-Monitoring Rules, Colleges and the FCC Have a Bad Connection
ERIC Educational Resources Information Center
Hartle, Terry W.
2006-01-01
A regulation issued by the US Federal Communications Commission (FCC) requires facilities-based Internet services providers who operate their own equipment, including colleges, to make their Internet systems compliant with a statute known as the Communications Assistance for Law Enforcement Act (Calea) by April 2007. However, the FCC does not…
A SCORM Compliant Courseware Authoring Tool for Supporting Pervasive Learning
ERIC Educational Resources Information Center
Wang, Te-Hua; Chang, Flora Chia-I
2007-01-01
The sharable content object reference model (SCORM) includes a representation of distance learning contents and a behavior definition of how users should interact with the contents. Generally, SCORMcompliant systems were based on multimedia and Web technologies on PCs. We further build a pervasive learning environment, which allows users to read…
40 CFR 63.4292 - What operating limits must I meet?
Code of Federal Regulations, 2010 CFR
2010-07-01
... systems on the web coating/printing operation(s) and dyeing/finishing operations for which you use this... Limitations § 63.4292 What operating limits must I meet? (a) For any web coating/printing operation, slashing operation, or dyeing/finishing operation on which you use the compliant material option; web coating...
This paper makes suggestions on how to comply with ANSI/ASQC E4-1994 while avoiding some of the frustration. Some options for writing a quality system document compliant with E4 are given, along with a model outline, to provide assistance in interpreting requirements.
Creating FGDC and NBII metadata with Metavist 2005.
David J. Rugg
2004-01-01
This report documents a computer program for creating metadata compliant with the Federal Geographic Data Committee (FGDC) 1998 metadata standard or the National Biological Information Infrastructure (NBII) 1999 Biological Data Profile for the FGDC standard. The software runs under the Microsoft Windows 2000 and XP operating systems, and requires the presence of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-29
...-compliant communications systems. The P25 CAP Program Manager will perform a simple administrative review to.... ADDRESSES: Interested persons are invited to submit comments, identified by docket number DHS-2011-0118, by... improving its information collection and urges all interested parties to suggest how these materials can...
Spontaneous Droplet Motion on a Periodically Compliant Substrate.
Liu, Tianshu; Nadermann, Nichole; He, Zhenping; Strogatz, Steven H; Hui, Chung-Yuen; Jagota, Anand
2017-05-23
Droplet motion arises in many natural phenomena, ranging from the familiar gravity-driven slip and arrest of raindrops on windows to the directed transport of droplets for water harvesting by plants and animals under dry conditions. Deliberate transportation and manipulation of droplets are also important in many technological applications, including droplet-based microfluidic chemical reactors and for thermal management. Droplet motion usually requires gradients of surface energy or temperature or external vibration to overcome contact angle hysteresis. Here, we report a new phenomenon in which a drying droplet placed on a periodically compliant surface undergoes spontaneous, erratic motion in the absence of surface energy gradients and external stimuli such as vibration. By modeling the droplet as a mass-spring system on a substrate with periodically varying compliance, we show that the stability of equilibrium depends on the size of the droplet. Specifically, if the center of mass of the drop lies at a stable equilibrium point of the system, it will stay there until evaporation reduces its size and this fixed point becomes unstable; with any small perturbation, the droplet then moves to one of its neighboring fixed points.
Fahlman, Andreas; Loring, Stephen H.; Johnson, Shawn P.; Haulena, Martin; Trites, Andrew W.; Fravel, Vanessa A.; Van Bonn, William G.
2014-01-01
We examined structural properties of the marine mammal respiratory system, and tested Scholander's hypothesis that the chest is highly compliant by measuring the mechanical properties of the respiratory system in five species of pinniped under anesthesia (Pacific harbor seal, Phoca vitulina; northern elephant seal, Mirounga angustirostris; northern fur seal Callorhinus ursinus; California sea lion, Zalophus californianus; and Steller sea lion, Eumetopias jubatus). We found that the chest wall compliance (CCW) of all five species was greater than lung compliance (airways and alveoli, CL) as predicted by Scholander, which suggests that the chest provides little protection against alveolar collapse or lung squeeze. We also found that specific respiratory compliance was significantly greater in wild animals than in animals raised in an aquatic facility. While differences in ages between the two groups may affect this incidental finding, it is also possible that lung conditioning in free-living animals may increase pulmonary compliance and reduce the risk of lung squeeze during diving. Overall, our data indicate that compliance of excised pinniped lungs provide a good estimate of total respiratory compliance. PMID:25426080
Xu Chen; Berry, Damon; Stephens, Gaye
2015-01-01
Computerised identity management is in general encountered as a low-level mechanism that enables users in a particular system or region to securely access resources. In the Electronic Health Record (EHR), the identifying information of both the healthcare professionals who access the EHR and the patients whose EHR is accessed, are subject to change. Demographics services have been developed to manage federated patient and healthcare professional identities and to support challenging healthcare-specific use cases in the presence of diverse and sometimes conflicting demographic identities. Demographics services are not the only use for identities in healthcare. Nevertheless, contemporary EHR specifications limit the types of entities that can be the actor or subject of a record to health professionals and patients, thus limiting the use of two level models in other healthcare information systems. Demographics are ubiquitous in healthcare, so for a general identity model to be usable, it should be capable of managing demographic information. In this paper, we introduce a generalised identity reference model (GIRM) based on key characteristics of five surveyed demographic models. We evaluate the GIRM by using it to express the EN13606 demographics model in an extensible way at the metadata level and show how two-level modelling can support the exchange of instances of demographic identities. This use of the GIRM to express demographics information shows its application for standards-compliant two-level modelling alongside heterogeneous demographics models. We advocate this approach to facilitate the interoperability of identities between two-level model-based EHR systems and show the validity and the extensibility of using GIRM for the expression of other health-related identities.
Labelling completeness and sodium content of packaged foods in India.
Johnson, Claire; Thout, Sudhir Raj; Mohan, Sailesh; Dunford, Elizabeth; Farrand, Clare; Wu, Jason Hy; He, Feng J; Shivashankar, Roopa; Webster, Jacqui; Krishnan, Anand; Garg, Vandana; Maulik, Pallab K; Prabhakaran, Dorairaj; Neal, Bruce
2017-11-01
To estimate the proportion of products meeting Indian government labelling regulations and to examine the Na levels in packaged foods sold in India. Nutritional composition data were collected from the labels of all packaged food products sold at Indian supermarkets in between 2012 and 2014. Proportions of products compliant with the Food Safety Standards Authority of India (FSSAI) regulations and labelled with Na content, and mean Na levels were calculated. Comparisons were made against 2010 data from Hyderabad and against the UK Department of Health (DoH) 2017 Na targets. Eleven large chain retail stores in Delhi and Hyderabad, India. Packaged food products (n 5686) categorised into fourteen food groups, thirty-three food categories and ninety sub-categories. More packaged food products (43 v. 34 %; P<0·001) were compliant with FSSAI regulations but less (32 v. 38 %; P<0·001) reported Na values compared with 2010. Food groups with the highest Na content were sauces and spreads (2217 mg/100 g) and convenience foods (1344 mg/100 g). Mean Na content in 2014 was higher in four food groups compared with 2010 and lower in none (P<0·05). Only 27 % of foods in sub-categories for which there are UK DoH benchmarks had Na levels below the targets. Compliance with nutrient labelling in India is improving but remains low. Many packaged food products have high levels of Na and there is no evidence that Indian packaged foods are becoming less salty.
What role does measuring medication compliance play in evaluating the efficacy of naltrexone?
Baros, Alicia M; Latham, Patricia K; Moak, Darlene H; Voronin, Konstantin; Anton, Raymond F
2007-04-01
Compliance with medication in pharmacotherapy trials of alcoholism has been shown to be equal to, or more, important than in other areas of medicine. Research has suggested that naltrexone's effectiveness can be greatly influenced by the compliance of participants in clinical trials. Presently, we compare 2 compliance measurement methods [urine riboflavin and medication event monitoring system (MEMS)] used simultaneously to evaluate naltrexone's efficacy and the impact of compliance on the size of observable treatment effects. One hundred and thirty-seven of 160 randomized alcoholic patients completed 12-weeks (84 days) of naltrexone or placebo and cognitive behavioral therapy (CBT) or motivational enhancement therapy (MET). Urine riboflavin was determined during study weeks 2, 6, and 12. The MEMS provided a detailed computerized record of when a participant opened their medication bottle throughout the trial. Baseline predictors of MEMS (80% openings) and urine riboflavin (>or=1,500 ng/mL by fluorimetry) compliance were examined. The effects of the treatments in the compliant participants defined by one, the other, or both methods were compared and contrasted with a previously reported intent-to-treat analysis where compliance was not taken into account. Age was predictive of compliance. 105 participants were deemed compliant via urine riboflavin criteria, 87 via MEMS, and 77 when both criteria were met, with no significant differences between treatment groups. The most compliant participants showed a significant medication by therapy interaction. Those treated with naltrexone/CBT showed more abstinence days (p<0.03), less heavy drinking days (p<0.03) and less total drinks (p<0.03) than the other groups. The effect size of this interaction increased from about 0.2 in the intent-to-treat analysis, to about 0.4 to 0.5 in the compliant group analyses, with little difference between compliance measurement methods. Compliance measurement does appear to influence the evaluation of the efficacy of naltrexone within the context of CBT. Treatment effect sizes approximately doubled in the most compliant individuals. Measuring compliance by either of 2 distinct methods provides approximately similar results. As compliance with naltrexone within the context of CBT has such a large impact of treatment outcome, methods of enhancing compliance during treatment should be given the utmost attention.
Jenett, Benjamin; Calisch, Sam; Cellucci, Daniel; Cramer, Nick; Gershenfeld, Neil; Swei, Sean; Cheung, Kenneth C
2017-03-01
We describe an approach for the discrete and reversible assembly of tunable and actively deformable structures using modular building block parts for robotic applications. The primary technical challenge addressed by this work is the use of this method to design and fabricate low density, highly compliant robotic structures with spatially tuned stiffness. This approach offers a number of potential advantages over more conventional methods for constructing compliant robots. The discrete assembly reduces manufacturing complexity, as relatively simple parts can be batch-produced and joined to make complex structures. Global mechanical properties can be tuned based on sub-part ordering and geometry, because local stiffness and density can be independently set to a wide range of values and varied spatially. The structure's intrinsic modularity can significantly simplify analysis and simulation. Simple analytical models for the behavior of each building block type can be calibrated with empirical testing and synthesized into a highly accurate and computationally efficient model of the full compliant system. As a case study, we describe a modular and reversibly assembled wing that performs continuous span-wise twist deformation. It exhibits high performance aerodynamic characteristics, is lightweight and simple to fabricate and repair. The wing is constructed from discrete lattice elements, wherein the geometric and mechanical attributes of the building blocks determine the global mechanical properties of the wing. We describe the mechanical design and structural performance of the digital morphing wing, including their relationship to wind tunnel tests that suggest the ability to increase roll efficiency compared to a conventional rigid aileron system. We focus here on describing the approach to design, modeling, and construction as a generalizable approach for robotics that require very lightweight, tunable, and actively deformable structures.
Digital Morphing Wing: Active Wing Shaping Concept Using Composite Lattice-Based Cellular Structures
Jenett, Benjamin; Calisch, Sam; Cellucci, Daniel; Cramer, Nick; Gershenfeld, Neil; Swei, Sean
2017-01-01
Abstract We describe an approach for the discrete and reversible assembly of tunable and actively deformable structures using modular building block parts for robotic applications. The primary technical challenge addressed by this work is the use of this method to design and fabricate low density, highly compliant robotic structures with spatially tuned stiffness. This approach offers a number of potential advantages over more conventional methods for constructing compliant robots. The discrete assembly reduces manufacturing complexity, as relatively simple parts can be batch-produced and joined to make complex structures. Global mechanical properties can be tuned based on sub-part ordering and geometry, because local stiffness and density can be independently set to a wide range of values and varied spatially. The structure's intrinsic modularity can significantly simplify analysis and simulation. Simple analytical models for the behavior of each building block type can be calibrated with empirical testing and synthesized into a highly accurate and computationally efficient model of the full compliant system. As a case study, we describe a modular and reversibly assembled wing that performs continuous span-wise twist deformation. It exhibits high performance aerodynamic characteristics, is lightweight and simple to fabricate and repair. The wing is constructed from discrete lattice elements, wherein the geometric and mechanical attributes of the building blocks determine the global mechanical properties of the wing. We describe the mechanical design and structural performance of the digital morphing wing, including their relationship to wind tunnel tests that suggest the ability to increase roll efficiency compared to a conventional rigid aileron system. We focus here on describing the approach to design, modeling, and construction as a generalizable approach for robotics that require very lightweight, tunable, and actively deformable structures. PMID:28289574
Norton, Kaila J; June, Kristie M; O'Connor, Richard J
2014-01-01
Electronic nicotine delivery systems (ENDS) present an emerging issue for tobacco control and data on product use behaviors are limited. Participants (N = 38 enrolled; N = 16 compliant) completed three lab visits over 5 days and were asked to abstain from regular cigarettes for 72 hours in favor of ENDS (Smoke 51 TRIO - 3 piece, First Generation with 11 mg/ml filters). Lab visits included measurement of exhaled carbon monoxide (CO) and salivary cotinine concentration, questionnaire measures of regular cigarette craving after the 72 hour abstinence, and subjective product effects. Participants used a topography device to record puff volume, duration, flow rate, and inter-puff interval. Analyses revealed significant differences across products in puff count, average volume, total volume and inter-puff interval, with ENDS broadly showing a more intensive smoking pattern. Cigarette craving scores dropped significantly after smoking regular cigarettes, but not ENDS (p = .001), and subjective measures showed ENDS rated less favorably. CO boost, after ENDS use, decreased significantly (p < .001), and saliva cotinine significantly dropped between visits 1 and 3 (p < 0.001) after ENDS use relative to after cigarette smoking. For compliant and non-compliant participants, there was an average 82.0% [V1 - 16.1 cpd; V3 - 2.9 cpd] and average 73.9% [V1 - 20.3 cpd; V3 - 5.3 cpd] reduction in regular cigarette use per day during the ENDS trial period, respectively. The ENDS were smoked more intensively than own brand cigarettes, but delivered significantly less nicotineand were less satisfying. These findings have implications for the viability of certain ENDS as alternatives to cigarettes.
Monitoring by Control Technique - Compliant (Low/No VOC/HAP) Inks and Coatings
Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about Compliant (Low/No VOC/HAP) Inks and Coatings control techniques used to reduce pollutant emissions.
48 CFR 39.106 - Year 2000 compliance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY General 39.106 Year 2000 compliance. When acquiring information technology that will be required to perform date/time processing involving dates... information technology to be Year 2000 compliant; or (2) Require that non-compliant information technology be...
NASA Astrophysics Data System (ADS)
Pahlevan, Niema; Gharib, Morteza
2012-11-01
Impedance pump is a simple valveless pumping mechanism that operates based on the principles of wave propagation and reflection. It has been shown in a zebrafish that a similar mechanism is responsible for the pumping action in the embryonic heart during early stages before valve formation. Recent studies suggest that the cardiovascular system is designed to take advantage of wave propagation and reflection phenomena in the arterial network. Our aim in this study was to examine if the human aorta is a passive pump working like an impedance pump. A hydraulic model with different compliant models of artificial aorta was used for series of in-vitro experiments. The hydraulic model includes a piston pump that generates the waves. Our result indicates that wave propagation and reflection can create pumping mechanism in a compliant aorta. Similar to an impedance pump, the net flow and the flow direction depends on the frequency of the waves, compliance of the aorta, and the piston stroke.
2010-05-01
allows task submission to be decoupled from low-level scheduling and thread management details. It provides the thread pool mechanism that allows a...resource management . In this compliant solution, the client’s doSomething() method provides only the required func- tionality by implementing the...doSomethingWithFile() method of the LockAction inter- face, without having to manage the acquisition and release of locks or the open and close opera
Mojave Compliant Zone Structure and Properties: Constraints from InSAR and Mechanical Models
NASA Astrophysics Data System (ADS)
Hearn, E. H.; Fialko, Y.; Finzi, Y.
2007-12-01
Long-lived zones with significantly lower elastic strength than their surroundings are associated with active Mojave faults (e.g., Li et al., 1999; Fialko et al., 2002, 2004). In an earthquake these weak features concentrate strain, causing them to show up as anomalous, short length-scale features in SAR interferograms (Fialko et al., 2002). Fault-zone trapped wave studies indicate that the 1999 Hector Mine earthquake caused a small reduction in P- and S-wave velocities in a compliant zone along the Landers earthquake rupture (Vidale and Li, 2003). This suggests that coseismic strain concentration, and the resulting damage, in the compliant zone caused a further reduction in its elastic strength. Even a small coseismic strength drop should make a compliant zone (CZ) deform, in response to the total (not just the coseismic) stress. The strain should be in the sense which is compatible with the orientations and values of the region's principal stresses. However, as indicated by Fialko and co-workers (2002, 2004), the sense of coseismic strain of Mojave compliant zones was consistent with coseismic stress change, not the regional (background) stress. Here we use finite-element models to investigate how InSAR measurements of Mojave compliant zone coseismic strain places limits on their dimensions and on upper crustal stresses. We find that unless the CZ is shallow, narrow, and has a high Poisson's ratio (e.g., 0.4), CZ contraction under lithostatic stress overshadows deformation due to deviatoric background stress or coseismic stress change. We present ranges of CZ dimensions which are compatible with the observed surface deformation and address how these dimensions compare with new results from damage-controlled fault evolution models.
The effect of compliant prisms on subduction zone earthquakes and tsunamis
NASA Astrophysics Data System (ADS)
Lotto, Gabriel C.; Dunham, Eric M.; Jeppson, Tamara N.; Tobin, Harold J.
2017-01-01
Earthquakes generate tsunamis by coseismically deforming the seafloor, and that deformation is largely controlled by the shallow rupture process. Therefore, in order to better understand how earthquakes generate tsunamis, one must consider the material structure and frictional properties of the shallowest part of the subduction zone, where ruptures often encounter compliant sedimentary prisms. Compliant prisms have been associated with enhanced shallow slip, seafloor deformation, and tsunami heights, particularly in the context of tsunami earthquakes. To rigorously quantify the role compliant prisms play in generating tsunamis, we perform a series of numerical simulations that directly couple dynamic rupture on a dipping thrust fault to the elastodynamic response of the Earth and the acoustic response of the ocean. Gravity is included in our simulations in the context of a linearized Eulerian description of the ocean, which allows us to model tsunami generation and propagation, including dispersion and related nonhydrostatic effects. Our simulations span a three-dimensional parameter space of prism size, prism compliance, and sub-prism friction - specifically, the rate-and-state parameter b - a that determines velocity-weakening or velocity-strengthening behavior. We find that compliant prisms generally slow rupture velocity and, for larger prisms, generate tsunamis more efficiently than subduction zones without prisms. In most but not all cases, larger, more compliant prisms cause greater amounts of shallow slip and larger tsunamis. Furthermore, shallow friction is also quite important in determining overall slip; increasing sub-prism b - a enhances slip everywhere along the fault. Counterintuitively, we find that in simulations with large prisms and velocity-strengthening friction at the base of the prism, increasing prism compliance reduces rather than enhances shallow slip and tsunami wave height.
2005-04-01
meet state and U.S. Air Force (Air Force) environmental requirements for the use of cleaning products and washing systems; comply with Air Force and...and O/WSs • Use environmentally compliant cleaning products and wash systems • Be equipped with a credit card reader or similar device, to document... cleaning products and washing systems, including operating a covered O/WS within design capacity limits • Comply with Air Force and Department of
1993-12-02
community) or not knowing MPT analysis evaluates human-in- loop costs and how to exploit data that were available to represent capabilities w;th intent...specification b. There is no closed loop ; the process may statements. An agency is preparing a System Specification with minimal security information...Item is one which musk alweys be provided by the CMI system to be AICC compliant. Core Items are those which a lesson may always depend upon being
Graphene-Mesoporous Si Nanocomposite as a Compliant Substrate for Heteroepitaxy.
Boucherif, Abderrahim Rahim; Boucherif, Abderraouf; Kolhatkar, Gitanjali; Ruediger, Andreas; Arès, Richard
2017-05-01
The ultimate performance of a solid state device is limited by the restricted number of crystalline substrates that are available for epitaxial growth. As a result, only a small fraction of semiconductors are usable. This study describes a novel concept for a tunable compliant substrate for epitaxy, based on a graphene-porous silicon nanocomposite, which extends the range of available lattice constants for epitaxial semiconductor alloys. The presence of graphene and its effect on the strain of the porous layer lattice parameter are discussed in detail and new remarkable properties are demonstrated. These include thermal stability up to 900 °C, lattice tuning up to 0.9 % mismatch, and compliance under stress for virtual substrate thicknesses of several micrometers. A theoretical model is proposed to define the compliant substrate design rules. These advances lay the foundation for the fabrication of a compliant substrate that could unlock the lattice constant restrictions for defect-free new epitaxial semiconductor alloys and devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Laboratory analysis of phacoemulsifier compliance and capacity.
Nejad, Mitra; Injev, Valentine P; Miller, Kevin M
2012-11-01
To compare the compliance and capacity of 7 fluidics modules used by 6 phacoemulsifiers from 3 manufacturers. Jules Stein Eye Institute, Los Angeles, California, USA. Experimental study. Previous-model and current-model phacoemulsifiers from 3 manufacturers were subjected to laboratory analysis of compliance and capacity. Previous-generation models tested included the Legacy Advantec, Whitestar Sovereign Phacoemulsification System, and Millennium Microsurgical System. Current models tested were the Infiniti Vision System with standard and Intrepid cassettes, Whitestar Signature Phacoemulsification System, and Stellaris Vision Enhancement System. To measure compliance, the aspiration line was connected to an electronic pressure transducer and small volumes of fluid were injected or aspirated. To measure capacity, the space between the distal end of the aspiration line and the pump was filled with methylene blue-dyed fluid. The Legacy was the most compliant phacoemulsifier. The old and new Whitestar systems, Millennium system, and Stellaris system showed similar midrange compliances. The Infiniti Vision System with the Intrepid fluidic management system was the least compliant. The Infiniti cassettes had the greatest capacity, which is a detriment from a surge-control perspective, and Signature cassettes had the least capacity. The Infiniti Intrepid system had the lowest compliance of the 6 units tested, which is optimum from a surge-control perspective. All other things being equal, the Infiniti should have the safest occlusion-break surge response. Mr. Injev is an employee of Alcon Laboratories. Dr. Miller is a consultant to and investigator for Alcon Laboratories. Ms. Nejad has no financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Lee, Ming-Chung; Shen, Yu-Chih; Wang, Ji-Hung; Li, Yu-Ying; Li, Tzu-Hsien; Chang, En-Ting; Wang, Hsiu-Mei
2017-01-01
Obstructive sleep apnea (OSA) is associated with bad cardiovascular outcomes and a high prevalence of anxiety and depression. This study investigated the effects of continuous positive airway pressure (CPAP) on the severity of anxiety and depression in OSA patients with or without coronary artery disease (CAD) and on the rate of cardio- and cerebro-vascular events in those with OSA and CAD. This prospective study included patients with moderate-to-severe OSA, with or without a recent diagnosis of CAD; all were started on CPAP therapy. Patients completed the Chinese versions of the Beck Anxiety Inventory (BAI) and Beck Depression Inventory-II (BDI-II) at baseline and after 6-month follow-up. The occurrence of major adverse cardiac and cerebrovascular events (MACCE) was assessed every 3 months up to 1 year. BAI scores decreased from 8.5 ± 8.4 at baseline to 5.4 ± 6.9 at 6 months in CPAP-compliant OSA patients without CAD ( P < 0.05). BAI scores also decreased from 20.7 ± 14.9 to 16.1 ± 14.5 in CPAP-compliant OSA patients with CAD. BDI-II scores decreased in CPAP-compliant OSA patients without CAD (from 11.1 ± 10.7 at baseline to 6.6 ± 9.5 at 6 months) and in CPAP-compliant OSA patients with CAD (from 20.4 ± 14.3 to 15.9 ± 7.3). In addition, there was a large effect size (ES) of BAI and BDI in 6-month CPAP treatment of OSA patients with CAD and a large ES in those with OSA under CPAP treatment. In OSA patients with CAD, the occurrence of MACCE was significantly lower in CPAP-compliant patients than that in CPAP noncompliant patients (11% in CPAP compliant and 50% in noncompliant; P < 0.05). CPAP improved anxiety and depression in OSA patients regardless of CAD. In OSA patients with CAD, CPAP-compliant patients had a lower 1-year rate of MACCE than CPAP-noncompliant patients.
NASA Technical Reports Server (NTRS)
Jiang, Yuhong; Zmood, R. B.
1996-01-01
Both self-excited and forced disturbances often lead to severe rotor vibrations in a magnetic bearing systems with long slender shafts. This problem has been studied using the H-infinity method, and stability with good robustness can be achieved for the linearized model of a magnetic bearing when small transient disturbances are applied. In this paper, the H-infinity control method for self-excited and forced disturbances is first reviewed. It is then applied to the control of a magnetic bearing rotor system. In modelling the system, the shaft is first discretized into 18 finite elements and then three levels of condensation are applied. This leads to a system with three masses and three compliant elements which can be described by six state variable coordinates. Simulation of the resultant system design has been performed at speeds up to 10,000 rpm. Disturbances in terms of different initial displacements, initial impulses, and external periodic inputs have been imposed. The simulation results show that good stability can be achieved under these different transient disturbances using the proposed controller while at the same time reducing the sensitivity to external periodic disturbances.
DIRAC3 - the new generation of the LHCb grid software
NASA Astrophysics Data System (ADS)
Tsaregorodtsev, A.; Brook, N.; Casajus Ramo, A.; Charpentier, Ph; Closier, J.; Cowan, G.; Graciani Diaz, R.; Lanciotti, E.; Mathe, Z.; Nandakumar, R.; Paterson, S.; Romanovsky, V.; Santinelli, R.; Sapunov, M.; Smith, A. C.; Seco Miguelez, M.; Zhelezov, A.
2010-04-01
DIRAC, the LHCb community Grid solution, was considerably reengineered in order to meet all the requirements for processing the data coming from the LHCb experiment. It is covering all the tasks starting with raw data transportation from the experiment area to the grid storage, data processing up to the final user analysis. The reengineered DIRAC3 version of the system includes a fully grid security compliant framework for building service oriented distributed systems; complete Pilot Job framework for creating efficient workload management systems; several subsystems to manage high level operations like data production and distribution management. The user interfaces of the DIRAC3 system providing rich command line and scripting tools are complemented by a full-featured Web portal providing users with a secure access to all the details of the system status and ongoing activities. We will present an overview of the DIRAC3 architecture, new innovative features and the achieved performance. Extending DIRAC3 to manage computing resources beyond the WLCG grid will be discussed. Experience with using DIRAC3 by other user communities than LHCb and in other application domains than High Energy Physics will be shown to demonstrate the general-purpose nature of the system.
Halpern, David; Gaver, Donald P.
2012-01-01
We investigate the influence of a soluble surfactant on the steady-state motion of a finger of air through a compliant channel. This study provides a basic model from which to understand the fluid–structure interactions and physicochemical hydrodynamics of pulmonary airway reopening. Airway closure occurs in lung diseases such as respiratory distress syndrome and acute respiratory distress syndrome as a result of fluid accumulation and surfactant insufficiency. This results in ‘compliant collapse’ with the airway walls buckled and held in apposition by a liquid occlusion that blocks the passage of air. Airway reopening is essential to the recovery of adequate ventilation, but has been associated with ventilator-induced lung injury because of the exposure of airway epithelial cells to large interfacial flow-induced pressure gradients. Surfactant replacement is helpful in modulating this deleterious mechanical stimulus, but is limited in its effectiveness owing to slow surfactant adsorption. We investigate the effect of surfactant on micro-scale models of reopening by computationally modelling the steady two-dimensional motion of a semi-infinite bubble propagating through a liquid-filled compliant channel doped with soluble surfactant. Many dimensionless parameters affect reopening, but we primarily investigate how the reopening pressure pb depends upon the capillary number Ca (the ratio of viscous to surface tension forces), the adsorption depth parameter λ (a bulk concentration parameter) and the bulk Péclet number Peb (the ratio of bulk convection to diffusion). These studies demonstrate a dependence of pb on λ, and suggest that a critical bulk concentration must be exceeded to operate as a low-surface-tension system. Normal and tangential stress gradients remain largely unaffected by physicochemical interactions – for this reason, further biological studies are suggested that will clarify the role of wall flexibility and surfactant on the protection of the lung from atelectrauma. PMID:22997476
2011 Information Systems Summit 2
2011-04-06
to automate. Some criteria that should be considered: – Are the tests easy to automate? What makes a test easy to automate is the ability to script...ANSI-748-B defines 32 criteria needs for a FAR/DFAR compliant Earned Value Management System. These criteria address 5 areas of Earned Value...are the basis of Increasing the Probability of Success of any program. But there are 11 critical criteria that must be present not matter what
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deserts, L. des
To develop hydrocarbon fields located in deep waters, several alternatives can be contemplated. Among these alternatives, some of them use surface wellheads while others use subsea wells; some alternatives are using bottom founded structures, while others use floating structures or a combination of both. The purpose of this paper is to try to assess when a compliant tower will be the most appropriate solution to consider. To make this assessment, the different types of compliant towers are recalled, as well as the different types of floating structures. Then some criteria are introduced to compare the different alternatives and to determinemore » when a compliant tower is the most appropriate solution.« less
NASA Technical Reports Server (NTRS)
Ruscitto, D.; Mccormick, J.; Gray, S.
1978-01-01
A 38.1 mm (1.5 inch) diameter Hydresil Compliant Surface Air Lubricated Journal Bearing was designed and tested to obtain bearing performance characteristics at both room temperature and 315 C (600 F). Testing was performed at various speeds up to 60,000 rpm with varying loads. Rotating sensors provided an opportunity to examine the film characteristics of the compliant surface bearing. In addition to providing minimum film thickness values and profiles, many other insights into bearing operation were gained such as the influence of bearing fabrication accuracy and the influence of smooth foil deflection between the bumps.
An experimental and theoretical study of structural damping in compliant foil bearings
NASA Technical Reports Server (NTRS)
Ku, C.-P. Roger
1994-01-01
This paper describes an experimental investigation into the dynamic characteristics of corrugated foil (bump foil) strips used in compliant surface foil bearings. This study provided and opportunity to quantify the structural damping of bump foil strips. The experimental data were compared to results obtained by a theoretical model developed earlier. The effects of bearing design parameters, such as static loads, dynamic displacement amplitudes, bump configurations, pivot locations, surface coatings, and lubricant were also evaluated. An understanding of the dynamic characteristics of bump foil strips resulting from this work offers designers a means for enhancing the design of high-performance compliant foil bearings.
Gozal, Yair M; Farley, Chad W; Hanseman, Dennis J; Harwell, Daniel; Magner, Mark; Andaluz, Norberto; Shutter, Lori
2014-08-01
Shortcomings created by the lack of both a uniform definition of ventriculostomy-associated infection (VAI) and reporting standards have led to widely ranging infections rates (2-24%) whose significance is uncertain. We propose a standardized definition of VAI and a consistent reporting format compliant with Centers for Disease Control and Prevention (CDC) for device-related infections. Using those parameters to establish an infection-control surveillance program, we report our 4-year institutional VAI rates. In this prospective study covering ventriculostomy utilization (October 2006-December 2010), 498 patients had a total of 4,673 ventriculostomy days. By review of the literature and our institutional analysis, we defined VAI as a positive CSF culture in a patient with ventriculostomy catheter, plus one or more of the following (1) fever recorded >101.5 °F or (2) cerebrospinal fluid (CSF) glucose level, either <50 mg/dL or <50% of a serum glucose level drawn within 24 h of the CSF glucose. In a report format that is CDC compliant, rates of VAI are reported. Among our patients, the CDC-compliant infection rate was 2.14 per 1,000 ventriculostomy days. Of the 10 VAIs occurring in 498 patients during 4,673 ventriculostomy days, this 2.0% infection rate was lower than the previously reported 8.8% composite rates of VAI. Average duration of ventriculostomy was 9.4 days. Neither antibiotic-impregnated catheters nor periprocedural or prophylactic antibiotics were used. Our standardized VAI definition and CDC format seems promising toward facilitating future study and guideline development. Given our strict protocol of sterile catheter placement and care, and our institution's low 2.0% infection rates, we propose an infection-rate target of ≤5 per 1,000 device days. Our results suggest that the use of antibiotics or antibiotic-impregnated catheters is unwarranted--a positive given concerns of evolving anti-microbial resistance.
USDA-ARS?s Scientific Manuscript database
SNARC has been working with the folks at AADAP on two studies: 1) a “near” GLP compliant Target Animal Safety study to evaluate the safety of Aquaflor® administered in feed to sunshine bass and 2) a GLP compliant Target Animal Safety study to evaluate the safety of 17a-methyltestosterone administere...
Standard requirements for GCP-compliant data management in multinational clinical trials
2011-01-01
Background A recent survey has shown that data management in clinical trials performed by academic trial units still faces many difficulties (e.g. heterogeneity of software products, deficits in quality management, limited human and financial resources and the complexity of running a local computer centre). Unfortunately, no specific, practical and open standard for both GCP-compliant data management and the underlying IT-infrastructure is available to improve the situation. For that reason the "Working Group on Data Centres" of the European Clinical Research Infrastructures Network (ECRIN) has developed a standard specifying the requirements for high quality GCP-compliant data management in multinational clinical trials. Methods International, European and national regulations and guidelines relevant to GCP, data security and IT infrastructures, as well as ECRIN documents produced previously, were evaluated to provide a starting point for the development of standard requirements. The requirements were produced by expert consensus of the ECRIN Working group on Data Centres, using a structured and standardised process. The requirements were divided into two main parts: an IT part covering standards for the underlying IT infrastructure and computer systems in general, and a Data Management (DM) part covering requirements for data management applications in clinical trials. Results The standard developed includes 115 IT requirements, split into 15 separate sections, 107 DM requirements (in 12 sections) and 13 other requirements (2 sections). Sections IT01 to IT05 deal with the basic IT infrastructure while IT06 and IT07 cover validation and local software development. IT08 to IT015 concern the aspects of IT systems that directly support clinical trial management. Sections DM01 to DM03 cover the implementation of a specific clinical data management application, i.e. for a specific trial, whilst DM04 to DM12 address the data management of trials across the unit. Section IN01 is dedicated to international aspects and ST01 to the competence of a trials unit's staff. Conclusions The standard is intended to provide an open and widely used set of requirements for GCP-compliant data management, particularly in academic trial units. It is the intention that ECRIN will use these requirements as the basis for the certification of ECRIN data centres. PMID:21426576
Keyhan, Sanaz; Acharya, Kelly S; Acharya, Chaitanya R; Yeh, Jason S; Provost, Meredith P; Goldfarb, James M; Muasher, Suheil J
2016-09-01
To determine whether IVF clinics are compliant with American Society for Reproductive Medicine (ASRM) and Society for Assisted Reproductive Technology (SART) (ASRM/SART) guidelines and assess the multiple pregnancy outcomes according to the number of embryos transferred. Retrospective cohort study. Not applicable. Data from 59,689 fresh first autologous IVF cycles from the 2011-2012 SART registry. None. Percentage of compliant cycles, multiple pregnancy rate (PR). Between 2011 and 2012, a total of 59,689 fresh first autologous cycles were analyzed. Among cleavage-stage ET cycles, the noncompliance rate ranged from 10%-27.4% depending on the age group. The multiple PR was significantly increased in noncompliant cycles involving patients <35 years (38.1% vs. 28.7%) and 35-37 years (35.4% vs. 24.5%) compared with compliant cycles. Among blastocyst-stage ET cycles, the highest rate of noncompliance was seen in patients <35 years old (71%), which resulted in a statistically higher multiple PR (48.3% vs. 2.8%) compared with compliant cycles. Far fewer cycles were noncompliant in patients 35-40 years of age. In a subanalysis of compliant cycles, transferring two blastocyst embryos in patients 35-37 years and 38-40 years resulted in a higher live birth rate compared with the transfer of one embryo (50.4% vs. 40.9% and 42.1% vs. 30.0%, respectively) but the multiple PR was also significantly higher (40.5% vs. 1.7% and 34.0% vs. 2.0%, respectively). Most first fresh autologous IVF cycles performed from 2011-2012 were compliant with ASRM/SART guidelines, except those that involved a blastocyst ET in patients <35 years. Despite compliance, cycles that involved the transfer of >1 embryo resulted in a high multiple PR, whereas noncompliant cycles resulted in an even more remarkable multiple PR for both cleavage and blastocyst-stage embryos. Clinics need to be more compliant with ET limits and ASRM/SART need to consider revising their guidelines to limit the number of blastocyst transfer to one in patients ≤40 years of age undergoing their first IVF cycle. Furthermore, decreasing the number of cleavage-stage embryos transferred in patients ≤40 years of age should also be considered. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harms, Kevin; Oral, H. Sarp; Atchley, Scott
The Oak Ridge and Argonne Leadership Computing Facilities are both receiving new systems under the Collaboration of Oak Ridge, Argonne, and Livermore (CORAL) program. Because they are both part of the INCITE program, applications need to be portable between these two facilities. However, the Summit and Aurora systems will be vastly different architectures, including their I/O subsystems. While both systems will have POSIX-compliant parallel file systems, their Burst Buffer technologies will be different. This difference may pose challenges to application portability between facilities. Application developers need to pay attention to specific burst buffer implementations to maximize code portability.
2010-12-01
Authority WCF Working Capital Fund Y2K Year 2000 xvi THIS PAGE INTENTIONALLY LEFT BLANK xvii ACKNOWLEDGMENTS We express our deepest...signaling the move away from mainframe systems. However, it was the year 2000 ( Y2K ) dilemma that ushered in unprecedented growth in the development of ERP...software and IT systems of the 1990s. The possibility of non- Y2K compliant legacy systems failing at the turn of the century resulted in the
Feature Selection on Hyperspectral Data for Dismount Skin Analysis
2014-03-27
19 2.4.1 Melanosome Estimation . . . . . . . . . . . . . . . . . . . . . . . 19 2.4.2 Facial Recognition using...require compliant interaction in order to establish their identification. Previously, traditional facial recognition systems have been enhanced by HSI by...calculated as a fundamental method to differentiate between people [38]. In addition, the area of facial recognition has benefited from the rich spectral
Mcdonald, Jacob D; Doyle-Eisele, Melanie; Gigliotti, Andrew; Miller, Rodney A; Seilkop, Steve; Mauderly, Joe L; Seagrave, JeanClare; Chow, Judith; Zielinska, Barbara
2012-09-01
The Health Effects Institute and its partners conceived and funded a program to characterize the emissions from heavy-duty diesel engines compliant with the 2007 and 2010 on-road emissions standards in the United States and to evaluate indicators of lung toxicity in rats and mice exposed repeatedly to diesel exhaust (DE*) from 2007-compliant engines. The preliminary hypothesis of this Advanced Collaborative Emissions Study (ACES) was that 2007-compliant on-road diesel emissions ". . . will not cause an increase in tumor formation or substantial toxic effects in rats and mice at the highest concentration of exhaust that can be used . . . although some biological effects may occur." This hypothesis is being tested at the Lovelace Respiratory Research Institute (LRRI) by exposing rats by chronic inhalation as a carcinogenicity bioassay, measuring indicators of pulmonary toxicity in rats after 1, 3, 12, and 24-30 months of exposure (final time point depends on the survival of animals), and measuring similar indicators of pulmonary toxicity in mice after 1 and 3 months of exposure. This report provides results of exposures through 3 months in rats and mice. Emissions from a 2007-compliant, 500-horsepower-class engine and aftertreatment system operated on a variable-duty cycle were used to generate the animal inhalation test atmospheres. Four treatment groups were exposed to one of three concentrations (dilutions) of exhaust combined with crankcase emissions, or to clean air as a negative control. Dilutions of exhaust were set to yield average integrated concentrations of 4.2, 0.8, and 0.1 ppm nitrogen dioxide (NO2). Exposure atmospheres were analyzed by daily measurements of key components and periodic detailed physical-chemical characterizations. Exposures were conducted 16 hr/dy (overnight), 5 dy/wk. Rats were evaluated for hematology, serum chemistry, bronchoalveolar lavage (BAL), lung cell proliferation, and histopathology after 1 month of exposure, and the same indicators plus pulmonary function after 3 months. Mice were evaluated for BAL, lung cell proliferation, and respiratory tract histopathology after 1 month of exposure, and the same indicators plus hematology and serum chemistry after 3 months. Samples from both species were collected for ancillary studies performed by investigators who were not at LRRI and were funded separately. Exposures were accomplished as planned, with average integrated exposure concentrations within 20% of the target dilutions. The major components were the gaseous inorganic compounds, nitrogen monoxide (NO), NO2, and carbon monoxide (CO). Minor components included low concentrations of diesel particulate matter (DPM) and volatile and semivolatile organic compounds (VOCs and SVOCs). There were no exposure-related differences in mortality or clinically evident morbidity. Among the more than 100 biologic response variables evaluated, the majority showed no significant difference from control as a result of exposure to DE. There was evidence of early lung changes in the rats, accompanied by a number of statistically significant increases in inflammatory and oxidative stress indicators, and some evidence of subtle changes in pulmonary function. In general, statistically significant effects were observed only at the highest exposure level. The mice did not have the same responses as the rats, but did have small but statistically significant increases in lavage neutrophils and the cytokine IL-6 at 1 month (but not at 3 months). These findings suggest that the rats were more sensitive than mice to the subchronic exposures.
78 FR 42406 - Airworthiness Directives; Eurocopter France Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-16
... 3 of the Rotorcraft Flight Manual. Many of the non-compliant servo-controls were installed by the... Emergency AD, we have discovered that the servo-control's component history card or equivalent record may... servo-controls with a non-compliant input lever bearing be replaced and returned to the manufacturer. AD...
An MPI-1 Compliant Thread-Based Implementation
NASA Astrophysics Data System (ADS)
Díaz Martín, J. C.; Rico Gallego, J. A.; Álvarez Llorente, J. M.; Perogil Duque, J. F.
This work presents AzequiaMPI, the first full compliant implementation of the MPI-1 standard where the MPI node is a thread. Performance comparisons with MPICH2-Nemesis show that thread-based implementations exploit adequately the multicore architectures under oversubscription, what could make MPI competitive with OpenMP-like solutions.
SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gauntt, D
2015-06-15
Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results ofmore » measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.« less
Design and control of compliant tensegrity robots through simulation and hardware validation.
Caluwaerts, Ken; Despraz, Jérémie; Işçen, Atıl; Sabelhaus, Andrew P; Bruce, Jonathan; Schrauwen, Benjamin; SunSpiral, Vytas
2014-09-06
To better understand the role of tensegrity structures in biological systems and their application to robotics, the Dynamic Tensegrity Robotics Lab at NASA Ames Research Center, Moffett Field, CA, USA, has developed and validated two software environments for the analysis, simulation and design of tensegrity robots. These tools, along with new control methodologies and the modular hardware components developed to validate them, are presented as a system for the design of actuated tensegrity structures. As evidenced from their appearance in many biological systems, tensegrity ('tensile-integrity') structures have unique physical properties that make them ideal for interaction with uncertain environments. Yet, these characteristics make design and control of bioinspired tensegrity robots extremely challenging. This work presents the progress our tools have made in tackling the design and control challenges of spherical tensegrity structures. We focus on this shape since it lends itself to rolling locomotion. The results of our analyses include multiple novel control approaches for mobility and terrain interaction of spherical tensegrity structures that have been tested in simulation. A hardware prototype of a spherical six-bar tensegrity, the Reservoir Compliant Tensegrity Robot, is used to empirically validate the accuracy of simulation. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
IXV avionics architecture: Design, qualification and mission results
NASA Astrophysics Data System (ADS)
Succa, Massimo; Boscolo, Ilario; Drocco, Alessandro; Malucchi, Giovanni; Dussy, Stephane
2016-07-01
The paper details the IXV avionics presenting the architecture and the constituting subsystems and equipment. It focuses on the novelties introduced, such as the Ethernet-based protocol for the experiment data acquisition system, and on the synergy with Ariane 5 and Vega equipment, pursued in order to comply with the design-to-cost requirement for the avionics system development. Emphasis is given to the adopted model philosophy in relation to OTS/COTS items heritage and identified activities necessary to extend the qualification level to be compliant with the IXV environment. Associated lessons learned are identified. Then, the paper provides the first results and interpretation from the flight recorders telemetry, covering the behavior of the Data Handling System, the quality of telemetry recording and real-time/delayed transmission, the performance of the batteries and the Power Protection and Distribution Unit, the ground segment coverage during visibility windows and the performance of the GNC sensors (IMU and GPS) and actuators. Finally, some preliminary tracks of the IXV follow on are given, introducing the objectives of the Innovative Space Vehicle and the necessary improvements to be developed in the frame of PRIDE.
Laboratory Information Systems Management and Operations.
Cucoranu, Ioan C
2015-06-01
The main mission of a laboratory information system (LIS) is to manage workflow and deliver accurate results for clinical management. Successful selection and implementation of an anatomic pathology LIS is not complete unless it is complemented by specialized information technology support and maintenance. LIS is required to remain continuously operational with minimal or no downtime and the LIS team has to ensure that all operations are compliant with the mandated rules and regulations. Copyright © 2015 Elsevier Inc. All rights reserved.
Reduced SWAP-C VICTORY Services Execution and Performance Evaluation
2012-08-01
NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) UBT, Inc.,3250 W Big Beaver Rd, Suite 329, Troy ,Mi,48084 8. PERFORMING...Symposium August 14-16 Troy , Michigan 14. ABSTRACT -Executing multiple VICTORY data services, and reading multiple VICTORY-compliant sensors at the...same time resulted in the following performance measurements for the system -0.64 Amps / 3.15 Watts Power Consumption at run-time. -Roughly 0.77% System
openEHR Based Systems and the General Data Protection Regulation (GDPR).
Sousa, Mariana; Ferreira, Duarte; Santos-Pereira, Cátia; Bacelar, Gustavo; Frade, Samuel; Pestana, Olívia; Cruz-Correia, Ricardo
2018-01-01
The concerns about privacy and personal data protection resulted in reforms of the existing legislation in European Union (EU). The General Data Protection Regulation (GDPR) aims to reform the existing measures on the topic of personal data protection of the European Union citizens, with a strong input on the rights and freedoms of people and in the establishment of rules for the processing of personal data. OpenEHR is a standard that embodies many principles of interoperable and secure software for electronic health records. This work aims to understand to what extent the openEHR standard can be considered a solution for the requirements needed by GDPR. A list of requirements for a Hospital Information Systems (HIS) compliant with GDPR and an identification of openEHR specifications was made. The requirements were categorized and compared with the specifications. The requirements identified for the systems were matched with the openEHR specifications, which result in 16 requirements matched with openEHR. All the specifications identified matched at least one requirement. OpenEHR is a solution for the development of HIS that reinforce privacy and personal data protection, ensuring that they are contemplated in the system development. The institutions can secure that their Eletronic Health Record are compliant with GDPR while safeguarding the medical data quality and, as a result, the healthcare delivery.
Seth, Ashok; Gupta, Sajal; Pratap Singh, Vivudh; Kumar, Vijay
2017-09-01
Final stent dimensions remain an important predictor of restenosis, target vessel revascularisation (TVR) and subacute stent thrombosis (ST), even in the drug-eluting stent (DES) era. Stent balloons are usually semi-compliant and thus even high-pressure inflation may not achieve uniform or optimal stent expansion. Post-dilatation with non-compliant (NC) balloons after stent deployment has been shown to enhance stent expansion and could reduce TVR and ST. Based on supporting evidence and in the absence of large prospective randomised outcome-based trials, post-dilatation with an NC balloon to achieve optimal stent expansion and maximal luminal area is a logical technical recommendation, particularly in complex lesion subsets.
Robotic Joints Support Horses and Humans
NASA Technical Reports Server (NTRS)
2008-01-01
A rehabilitative device first featured in Spinoff 2003 is not only helping human patients regain the ability to walk, but is now helping our four-legged friends as well. The late James Kerley, a prominent Goddard Space Flight Center researcher, developed cable-compliant mechanisms in the 1980s to enable sounding rocket assemblies and robots to grip or join objects. In cable-compliant joints (CCJs), short segments of cable connect structural elements, allowing for six directions of movement, twisting, alignment, and energy damping. Kerley later worked with Goddard s Wayne Eklund and Allen Crane to incorporate the cable-compliant mechanisms into a walker for human patients to support the pelvis and imitate hip joint movement.
Operational Plan for Underground Storage Tank 322 R2U2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, D.
2017-06-07
This Operational Plan provides the operator of the tank system with guidelines relating to the safe and compliant operation and maintenance of the tank system. The tank system schematic and list of emergency contacts shall be posted near the tank so they are visible to tank personnel. This Operational Plan shall be kept on file by the Facility Supervisor. It should be understood when managing this tank system that it is used to store hazardous waste temporarily for 90 calendar days or less. The rinsewater handled in the tank system is considered hazardous and may exhibit the characteristic of toxicity.
NASA Technical Reports Server (NTRS)
Voellmer, George
1997-01-01
The Goddard Space Flight Center has developed the Robot Operated Materials Processing System (ROMPS) that flew aboard STS-64 in September, 1994. The ROMPS robot transported pallets containing wafers of different materials from their storage racks to a furnace for thermal processing. A system of tapered guides and compliant springs was designed to deal with the potential misalignments. The robot and all the sample pallets were locked down for launch and landing. The design of the passive lockdown system, and the interplay between it and the alignment system are presented.
VOC/HAP control systems for the shipbuilding and aerospace industries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lukey, M.E.; Toothman, D.A.
1999-07-01
Compliant coating systems, i.e., those which meet limits on pounds of volatile organic compound (VOC)/hazardous air pollutant (HAP) per gallon, on a solids applied basis, are routinely used to meet emission regulations in the shipbuilding and aerospace industries. However, there are occasions when solvent based systems must be used. Total capture and high destruction of the solvents in those systems is necessary in order to meet the required emission limit, e.g., a reasonably available control technology (RACT) limit of 3.5lbs of VOC/gallon. Water based marine coatings and certain aerospace finish coats do not provide sufficient longevity or meet other customermore » specifications in these instances. Furthermore, because of best available control technology (BACT) determinations or facility limits for operation in serious, severe, and extreme nonattainment areas, it is necessary to reduce annual emissions to levels which are below the levels required by the coating standards. The paper discusses those operations for controlling emissions from large-scale solvent based painting and coating systems in those instances when a high degree of overall control is required. Permanent total enclosures (stationary and portable), concentrators, regenerative thermal oxidizers, and other air pollution control systems are evaluated, both for technical applicability and economic feasibility. Several case studies are presented which illustrate techniques for capturing painting emissions, options for air handling in the workplace, and methods for destroying exhaust stream VOC concentrations of less than 40 ppm.« less
Experience of plastic surgery registrars in a European Working Time Directive compliant rota.
de Blacam, Catherine; Tierney, Sean; Shelley, Odhran
2017-08-01
Surgical training requires exposure to clinical decision-making and operative experience in a supervised environment. It is recognised that learning ability is compromised when fatigued. The European Working Time Directive requires a decrease in working hours, but compliance reduces trainees' clinical exposure, which has profound implications for plastic surgery training. The aim of this study was to evaluate plastic surgery registrars' experience of an EWTD-compliant rota, and to examine its impact on patient care, education, and logbook activity. An electronic survey was distributed to plastic surgery registrars in a university teaching hospital. Registrars were asked to rate 31 items on a five-point Likert scale, including statements on patient care, clinical and operative duties, training, and quality-of-life. Interquartile deviations explored consensus among responses. Operative caseload was objectively evaluated using eLogbook data to compare activity at equal time points before and after implementation of the EWTD rota. Highest levels of consensus among respondents were found in positive statements addressing alertness and preparation for theatre, as well as time to read and study for exams. Registrars agreed that EWTD compliance improved their quality-of-life. However, it was felt that continuity of patient care was compromised by work hours restriction. Registrars were concerned about their operative experience. eLogbook data confirmed a fall-off in mean caseload of 31.8% compared to activity prior to EWTD rota implementation. While EWTD compliant rotas promote trainee quality-of-life and satisfaction with training, attention needs to be paid to optimising operative opportunities.
NASA Technical Reports Server (NTRS)
Kerley, James J.; Eklund, Wayne; Crane, Alan
1992-01-01
Walker supports person with limited use of legs and back. Enables person to stand upright, move with minimum load, and rest at will taking weight off legs. Consists of wheeled frame with body harness connected compliantly to side structures. Harness supports wearer upright when wearer relaxes and takes weight off lower extremities. Assumes partial to full body weight at user's discretion.
40 CFR 63.4291 - What are my options for meeting the emission limits?
Code of Federal Regulations, 2011 CFR
2011-07-01
... option. (b) Slashing. You must use the compliant material option to demonstrate that the mass fraction of... dyeing/finishing affected source. (1) Compliant material option. Demonstrate that the mass fraction of... paragraphs (4)(i) through (iv) of this paragraph. (i) The fraction of organic HAP applied in your dyeing...
40 CFR 63.4291 - What are my options for meeting the emission limits?
Code of Federal Regulations, 2014 CFR
2014-07-01
... option. (b) Slashing. You must use the compliant material option to demonstrate that the mass fraction of... dyeing/finishing affected source. (1) Compliant material option. Demonstrate that the mass fraction of... paragraphs (4)(i) through (iv) of this paragraph. (i) The fraction of organic HAP applied in your dyeing...
40 CFR 63.4291 - What are my options for meeting the emission limits?
Code of Federal Regulations, 2013 CFR
2013-07-01
... option. (b) Slashing. You must use the compliant material option to demonstrate that the mass fraction of... dyeing/finishing affected source. (1) Compliant material option. Demonstrate that the mass fraction of... paragraphs (4)(i) through (iv) of this paragraph. (i) The fraction of organic HAP applied in your dyeing...
40 CFR 63.4291 - What are my options for meeting the emission limits?
Code of Federal Regulations, 2012 CFR
2012-07-01
... option. (b) Slashing. You must use the compliant material option to demonstrate that the mass fraction of... dyeing/finishing affected source. (1) Compliant material option. Demonstrate that the mass fraction of... paragraphs (4)(i) through (iv) of this paragraph. (i) The fraction of organic HAP applied in your dyeing...
VCM Process Design: An ABET 2000 Fully Compliant Project
ERIC Educational Resources Information Center
Benyahia, Farid
2005-01-01
A long experience in undergraduate vinyl chloride monomer (VCM) process design projects is shared in this paper. The VCM process design is shown to be fully compliant with ABET 2000 criteria by virtue of its abundance in chemical engineering principles, integration of interpersonal and interdisciplinary skills in design, safety, economics, and…
Elastic energy distribution in bi-material lithosphere: implications for shear zone formation
NASA Astrophysics Data System (ADS)
So, B.; Yuen, D. A.
2013-12-01
Shear instability in the lithosphere can cause mechanical rupturing such as slab detachment and deep focus earthquake. Recent studies reported that bi-material interface, which refers to sharp elastic modulus contrast, plays an important role in triggering the instability [So and Yuen et al., 2012, GJI]. In present study, we performed two-dimensional numerical simulations to investigate the distribution of thermal-mechanical energy within the bi-material lithosphere. Under the far-field constant compression exerted on the domain, a larger elastic energy is accumulated into the compliant part than stiff medium. For instance, the compliant part has two times greater elastic energy density than surrounding stiff part, when the elastic modulus contrast between two different parts is five. Although these elastic energies in both parts are conversed into thermal energies after plastic yielding, denser elastic energy in the compliant is released more efficiently. This leads to efficient strength weakening and the subsequent ductile shear zone in the compliant part. We propose that strong shear heating occurs in lithosphere with the bi-material interface due to locally non-uniform distribution of the energy around the interface.
Kaupisch, A; Kennedy, L; Stelmanis, V; Tye, B; Kane, N M; Mountford, J C; Courtney, A; Baker, A H
2012-10-01
Revascularisation of ischaemic tissue remains an area of substantial unmet clinical need in cardiovascular disease. Strategies to induce therapeutic angiogenesis are therefore attractive. Our recent focus has been on human embryonic stem cell (hESC) strategies since hESC can be maintained in a pluripotent state or differentiated into any desired cell type, including endothelial cells (EC), under defined differentiation culture conditions. We recently published a protocol for non-good manufacturing practice (GMP) feeder- and serum-free hESC-EC-directed monolayer differentiation to vascular EC demonstrating the potential to generate hESC-derived EC in a GMP-compliant manner suitable for use in clinical trials. In this study we modified that laboratory protocol to GMP compliance. EC production was confirmed by flow cytometry, qRT-PCR and production of vascular structures in Matrigel®, yielding approximately 30 % mature VE-cadherin(+)/PECAM-1(+) cells using the GMP-compliant hESC line RC13. In conclusion, we have successfully demonstrated the production of vascular EC under GMP-compliant conditions suitable for clinical evaluation.
Inside the black box of food safety: a qualitative study of 'non-compliance' among food businesses.
Brough, Mark; Davies, Belinda; Johnstone, Eleesa
2016-04-01
Issue addressed This paper examines the meaning of food safety among food businesses deemed non-compliant and considers the need for an insider perspective to inform a more nuanced health promotion practice. Methods In-depth interviews were conducted with 29 food business operators who had recently been deemed 'non-compliant' through Council inspection. Results Paradoxically, these 'non-compliers' revealed a strong belief in the importance of food safety as well as a desire to comply with the regulations as communicated to them by Environmental Health Officers. Conclusions The evidence base of food safety is largely informed by the science of food hazards, yet there is a very important need to consider the practical daily application of food safety practices. This requires a more socially nuanced appreciation of food businesses beyond the simple dichotomy of compliant/ non-compliant. So what? Armed with a deeper understanding of the social context surrounding food safety practice, it is anticipated that a more balanced, collaborative mode of food safety health promotion could develop, which could add to the current model of regulation.
Shih, Huan-Yu; Shiojiri, Makoto; Chen, Ching-Hsiang; Yu, Sheng-Fu; Ko, Chung-Ting; Yang, Jer-Ren; Lin, Ray-Ming; Chen, Miin-Jang
2015-09-02
High threading dislocation (TD) density in GaN-based devices is a long unresolved problem because of the large lattice mismatch between GaN and the substrate, which causes a major obstacle for the further improvement of next-generation high-efficiency solid-state lighting and high-power electronics. Here, we report InGaN/GaN LEDs with ultralow TD density and improved efficiency on a sapphire substrate, on which a near strain-free GaN compliant buffer layer was grown by remote plasma atomic layer deposition. This "compliant" buffer layer is capable of relaxing strain due to the absorption of misfit dislocations in a region within ~10 nm from the interface, leading to a high-quality overlying GaN epilayer with an unusual TD density as low as 2.2 × 10(5) cm(-2). In addition, this GaN compliant buffer layer exhibits excellent uniformity up to a 6" wafer, revealing a promising means to realize large-area GaN hetero-epitaxy for efficient LEDs and high-power transistors.
Human-robot interaction: kinematics and muscle activity inside a powered compliant knee exoskeleton.
Knaepen, Kristel; Beyl, Pieter; Duerinck, Saartje; Hagman, Friso; Lefeber, Dirk; Meeusen, Romain
2014-11-01
Until today it is not entirely clear how humans interact with automated gait rehabilitation devices and how we can, based on that interaction, maximize the effectiveness of these exoskeletons. The goal of this study was to gain knowledge on the human-robot interaction, in terms of kinematics and muscle activity, between a healthy human motor system and a powered knee exoskeleton (i.e., KNEXO). Therefore, temporal and spatial gait parameters, human joint kinematics, exoskeleton kinetics and muscle activity during four different walking trials in 10 healthy male subjects were studied. Healthy subjects can walk with KNEXO in patient-in-charge mode with some slight constraints in kinematics and muscle activity primarily due to inertia of the device. Yet, during robot-in-charge walking the muscular constraints are reversed by adding positive power to the leg swing, compensating in part this inertia. Next to that, KNEXO accurately records and replays the right knee kinematics meaning that subject-specific trajectories can be implemented as a target trajectory during assisted walking. No significant differences in the human response to the interaction with KNEXO in low and high compliant assistance could be pointed out. This is in contradiction with our hypothesis that muscle activity would decrease with increasing assistance. It seems that the differences between the parameter settings of low and high compliant control might not be sufficient to observe clear effects in healthy subjects. Moreover, we should take into account that KNEXO is a unilateral, 1 degree-of-freedom device.
Sughayer, Maher A; Souan, Lina
2015-01-01
King Hussein Cancer (KHCC) is a specialized cancer center that treats both adult and pediatric cancer patients from Jordan and the neighboring countries. KHCC is acknowledged as a leader in cancer treatment in the Middle East and its vision is to maintain its leading position in cancer therapy and research. Hence, KHCC embarked on establishing the first ISO compliant cancer biobank (KHCCBIO) in Jordan.Currently, there are very few biobanks in the Middle East, hence, KHCC wanted to change this situation by establishing an ISO-compliant cancer biobank which would incorporate all current international guidelines and best-in class practices under an approved quality management system for the benefit of researchers in Jordan, its neighboring countries, and throughout the world. The established biobank would follow the highest ethical standards in collecting, processing, storing and distributing high-quality, clinically annotated biospecimens.The strategy used in establishing KHCCBIO was based on taking advantage of international networking and collaboration. This in essence led to knowledge transfer between well established organizations, institutions and individuals from Europe and Jordan, in existing technological innovation and internationally recognized quality standards. KHCC efforts were facilitated by a grant from the European Union under the seventh frame work program.Future aims of KHCCBIO are to develop KHCC's research infrastructure, increase its scope and visibility and improve its competitiveness throughout the biomedical science arena. Moreover, KHCCBIO is aiming to establish a platform for future knowledge transfer and collaborative research; develop partnerships between European and Middle Eastern organizations.
NASA Astrophysics Data System (ADS)
Sreekumar, M.; Nagarajan, T.; Singaperumal, M.
2008-12-01
This experimental study investigates the coupled effect of the force developed by the shape memory alloy (SMA) actuators and the force required for the large deflection of an elastica member in a compliant parallel mechanism. The compliant mechanism developed in house consists of a moving platform mounted on a superelastic pillar and three SMA wire actuators to manipulate the platform. A three-axis MEMS accelerometer has been mounted on the moving platform to measure its tilt angle. Three miniature force sensors have been designed and fabricated out of cantilever beams, each mounted with a pair of strain gauges, to measure the force developed by the respective actuators. The force sensors are highly sensitive and cost effective compared to commercially available miniature force sensors. Calibration of the force sensors has been accomplished with known weights, and for the three-axis MEMS accelerometer a rotary base has been considered which is usually used in optical applications. The calibration curves obtained, with R-squared values between 0.9997 and 1.0, show that both the tilt and force sensors considered are most appropriate for the respective applications. The mechanism fixed with the sensors and the drivers for the SMA actuators is integrated with a National Instrument's data acquisition system. The experimental results have been compared with the analytical results and it was found that the relative error is less than 2%. This is a preliminary study in the development of a mechanism for eye prosthesis and similar applications.
MEDWISE: an innovative public health information system infrastructure.
Sahin, Yasar Guneri; Celikkan, Ufuk
2012-06-01
In this paper, we present MedWise, a high level design of a medical information infrastructure, and its architecture. The proposed system offers a comprehensive, modular, robust and extensible infrastructure to be used in public health care systems. The system gathers reliable and evidence based health data, which it then classifies, interprets and stores into a particular database. It creates a healthcare ecosystem that aids the medical community by providing for less error prone diagnoses and treatment of diseases. This system will be standards-compliant; therefore it would be complementary to the existing healthcare and clinical information systems. The key objective of the proposed system is to provide as much medical historical and miscellaneous data as possible about the patients with minimal consultation, thus allowing physicians to easily access Patients' Ancillary Data (PAD) such as hereditary, residential, travel, custom, meteorological, biographical and demographical data before the consultation. In addition, the system can help to diminish problems and misdiagnosis situations caused by language barriers-disorders and misinformation. MedWise can assist physicians to shorten time for diagnosis and consultations, therefore dramatically improving quality and quantity of the physical examinations of patients. Furthermore, since it intends to supply a significant amount of data, it may be used to improve skills of students in medical education.
40 CFR 63.4500 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
...) for which you use the compliant material option or the emission rate without add-on controls option... § 63.4490 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.4492 at all times except...
40 CFR 63.4500 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
...) for which you use the compliant material option or the emission rate without add-on controls option... § 63.4490 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.4492 at all times except...
40 CFR 63.3900 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... operation(s) for which you use the compliant material option or the emission rate without add-on controls... § 63.3890 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.3892 at all times except...
40 CFR 63.4500 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) for which you use the compliant material option or the emission rate without add-on controls option... § 63.4490 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.4492 at all times except...
40 CFR 63.3900 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... operation(s) for which you use the compliant material option or the emission rate without add-on controls... § 63.3890 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.3892 at all times except...
40 CFR 63.3900 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... operation(s) for which you use the compliant material option or the emission rate without add-on controls... § 63.3890 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.3892 at all times except...
40 CFR 63.3900 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
...) for which you use the compliant material option or the emission rate without add-on controls option... § 63.3890 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.3892 at all times except...
40 CFR 63.3900 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) for which you use the compliant material option or the emission rate without add-on controls option... § 63.3890 at all times. (2) Any coating operation(s) for which you use the emission rate with add-on... for emission capture systems and add-on control devices required by § 63.3892 at all times except...
NASA Operational Environment Team (NOET) - NASA's key to environmental technology
NASA Technical Reports Server (NTRS)
Cook, Beth
1993-01-01
NOET is a NASA-wide team which supports the research and development community by sharing information both in person and via a computerized network, assisting in specification and standard revisions, developing cleaner propulsion systems, and exploring environmentally compliant alternatives to current processes. NOET's structure, dissemination of materials, electronic information, EPA compliance, specifications and standards, and environmental research and development are discussed.
INCOMMANDS TDP: Human Factors Evaluation of the Command Decision Support Capability Prototype
2009-03-01
CDSC) design with guidelines and principles stipulated in the INCOMMANDS TDP Human Factors Design and Evaluation Guide. 2. Usability and Utility...INCOMMANDS CDSC. The Heuristic Evaluation helps to ensure that the design of system is compliant with HCI best practices. Whereas the Usability and...implemented to confirm compliance with the INCOMMANDS TDP Human Factors Design and Evaluation Guide
NCBI2RDF: enabling full RDF-based access to NCBI databases.
Anguita, Alberto; García-Remesal, Miguel; de la Iglesia, Diana; Maojo, Victor
2013-01-01
RDF has become the standard technology for enabling interoperability among heterogeneous biomedical databases. The NCBI provides access to a large set of life sciences databases through a common interface called Entrez. However, the latter does not provide RDF-based access to such databases, and, therefore, they cannot be integrated with other RDF-compliant databases and accessed via SPARQL query interfaces. This paper presents the NCBI2RDF system, aimed at providing RDF-based access to the complete NCBI data repository. This API creates a virtual endpoint for servicing SPARQL queries over different NCBI repositories and presenting to users the query results in SPARQL results format, thus enabling this data to be integrated and/or stored with other RDF-compliant repositories. SPARQL queries are dynamically resolved, decomposed, and forwarded to the NCBI-provided E-utilities programmatic interface to access the NCBI data. Furthermore, we show how our approach increases the expressiveness of the native NCBI querying system, allowing several databases to be accessed simultaneously. This feature significantly boosts productivity when working with complex queries and saves time and effort to biomedical researchers. Our approach has been validated with a large number of SPARQL queries, thus proving its reliability and enhanced capabilities in biomedical environments.
Environmental performance of green building code and certification systems.
Suh, Sangwon; Tomar, Shivira; Leighton, Matthew; Kneifel, Joshua
2014-01-01
We examined the potential life-cycle environmental impact reduction of three green building code and certification (GBCC) systems: LEED, ASHRAE 189.1, and IgCC. A recently completed whole-building life cycle assessment (LCA) database of NIST was applied to a prototype building model specification by NREL. TRACI 2.0 of EPA was used for life cycle impact assessment (LCIA). The results showed that the baseline building model generates about 18 thousand metric tons CO2-equiv. of greenhouse gases (GHGs) and consumes 6 terajoule (TJ) of primary energy and 328 million liter of water over its life-cycle. Overall, GBCC-compliant building models generated 0% to 25% less environmental impacts than the baseline case (average 14% reduction). The largest reductions were associated with acidification (25%), human health-respiratory (24%), and global warming (GW) (22%), while no reductions were observed for ozone layer depletion (OD) and land use (LU). The performances of the three GBCC-compliant building models measured in life-cycle impact reduction were comparable. A sensitivity analysis showed that the comparative results were reasonably robust, although some results were relatively sensitive to the behavioral parameters, including employee transportation and purchased electricity during the occupancy phase (average sensitivity coefficients 0.26-0.29).
High temperature braided rope seals for static sealing applications
NASA Technical Reports Server (NTRS)
Adams, Michael L.; Olsen, Andrew; Darolia, Ram; Steinetz, Bruce M.; Bartolotta, Paul A.
1996-01-01
Achieving efficiency and performance goals of advanced aircraft and industrial systems are leading designers to implement high temperature materials such as ceramics and intermetallics. Generally these advanced materials are applied selectively in the highest temperature sections of the engine system including the combustor and high pressure turbine, amongst others. Thermal strains that result in attaching the low expansion-rate components to high expansion rate superalloy structures can cause significant life reduction in the components. Seals are being designed to both seal and to serve as compliant mounts allowing for relative thermal growths between high temperature but brittle primary structures and the surrounding support structures. Designers require high temperature, low-leakage, compliant seals to mitigate thermal stresses and control parasitic and cooling airflow between structures. NASA is developing high temperature braided rope seals in a variety of configurations to help solve these problems. This paper will describe the types of seals being developed, describe unique test techniques used to assess seal performance, and present leakage flow data under representative pressure, temperature and scrubbing conditions. Feasibility of the braided rope seals for both an industrial tube seal and a turbine vane seal application is also demonstrated.
A force compliant surgical robotic tool with IPMC actuator and integrated sensing
NASA Astrophysics Data System (ADS)
Fu, Lixue; McDaid, Andrew J.; Aw, Kean C.
2013-08-01
A robotic surgical device, actuated by Ionic Polymer-metal Composite (IPMC), integrated with a strain gauge to achieve force control is proposed. Test results have proved the capabilities of this device to conduct surgical procedures. The recent growth of patient acceptance and demand for robotic aided surgery has stimulated the progress of research where in many applications the performance has been proven to surpass human surgeons. A new area which uses the inherently force compliant and back-drivable properties of polymers, IPMC in this case, has shown its potential to undertake precise surgical procedures in delicate environments of medical practice. This is because IPMCs have similar actuation characteristics to real biological systems ensuring the safety of the practice. Nevertheless, little has been done in developing IPMCs as a rotary joint actuators used as functional surgical devices. This research demonstrates the design of a single degree of freedom (1DOF) robotic surgical instrument with one joint mechanism actuated by IPMC with an embedded strain gauge as a feedback unit, and controlled by a scheduled gain PI controller. With the simplicity of the system it was proven to be able to cut to the desired controlled force and hence depth.
Foil bearing performance in liquid nitrogen and liquid oxygen
NASA Technical Reports Server (NTRS)
Genge, Gary G.; Saville, Marshall; Gu, Alston
1993-01-01
Space transfer vehicles and other power and propulsion systems require long-life turbopumps. Rolling-element bearings used in current turbopumps do not have sufficient life for these applications. Process fluid foil bearings have established long life, with exceptional reliability, over a wide range of temperatures and fluids in many high-speed turbomachinery applications. However, actual data on bearing performance in cryogenic fluids has been minimal. The National Aeronautics and Space Administration (NASA) and AlliedSignal Aerospace Systems and Equipment (ASE) have attempted to characterize the leaf-type compliant foil bearing in oxygen and nitrogen. The work performed under a joint internal research and development program between Marshall Space Flight Center (MSFC) and ASE demonstrated that the foil bearing has load capacities of at least 266 psi in liquid oxygen and 352 psi in liquid nitrogen. In addition, the bearing demonstrated a direct damping coefficient of 40 to 50 lb-sec/in. with a damping ratio of .7 to 1.4 in. liquid nitrogen using a bearing sized for upper-stage turbopumps. With the results from this testing and the years of successful use in air cycle machines and other applications, leaf-type compliant foil bearings are ready for testing in liquid oxygen turbopumps.
Simplified Metadata Curation via the Metadata Management Tool
NASA Astrophysics Data System (ADS)
Shum, D.; Pilone, D.
2015-12-01
The Metadata Management Tool (MMT) is the newest capability developed as part of NASA Earth Observing System Data and Information System's (EOSDIS) efforts to simplify metadata creation and improve metadata quality. The MMT was developed via an agile methodology, taking into account inputs from GCMD's science coordinators and other end-users. In its initial release, the MMT uses the Unified Metadata Model for Collections (UMM-C) to allow metadata providers to easily create and update collection records in the ISO-19115 format. Through a simplified UI experience, metadata curators can create and edit collections without full knowledge of the NASA Best Practices implementation of ISO-19115 format, while still generating compliant metadata. More experienced users are also able to access raw metadata to build more complex records as needed. In future releases, the MMT will build upon recent work done in the community to assess metadata quality and compliance with a variety of standards through application of metadata rubrics. The tool will provide users with clear guidance as to how to easily change their metadata in order to improve their quality and compliance. Through these features, the MMT allows data providers to create and maintain compliant and high quality metadata in a short amount of time.
Oil-Free Shaft Support System Rotordynamics: Past, Present, and Future Challenges and Opportunities
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher
2011-01-01
Recent breakthroughs in Oil-Free technologies have enabled new high-speed rotor systems and turbomachinery. Such technologies can include compliant-surface gas bearings, magnetic bearings, and advanced solid lubricants and tribo-materials. This presentation briefly reviews critical technology developments and the current state-of-the-art, emerging Oil-Free rotor systems and discusses obstacles preventing more widespread use. Key examples of "best practices" for deploying Oil-Free technologies will be presented and remaining major technical questions surrounding Oil-Free technologies will be brought forward.
The Carnegie Mellon University Insert Project
1997-02-01
Real - Time Systems (INSERT) project under the DARPA Evolutionary Design for Complex Software (EDCS) Program. The INSERT team has completed an initial API definition and ported the existing real-time publication subscription group communication software to LynxOS 2.4, a POSIX.1b compliant OS. The distributed real-time publisher/subscriber communication model is now supported by a processor membership protocol which allows a node in the system to fail, or to rejoin the system later. When a node fails, all the publishers and subscribers on that node have to be
NASA Technical Reports Server (NTRS)
Shalkhauser, Mary Jo W.; Roche, Rigoberto
2017-01-01
The Space Telecommunications Radio System (STRS) provides a common, consistent framework for software defined radios (SDRs) to abstract the application software from the radio platform hardware. The STRS standard aims to reduce the cost and risk of using complex, configurable and reprogrammable radio systems across NASA missions. To promote the use of the STRS architecture for future NASA advanced exploration missions, NASA Glenn Research Center (GRC) developed an STRS-compliant SDR on a radio platform used by the Advance Exploration System program at the Johnson Space Center (JSC) in their Integrated Power, Avionics, and Software (iPAS) laboratory. The iPAS STRS Radio was implemented on the Reconfigurable, Intelligently-Adaptive Communication System (RIACS) platform, currently being used for radio development at JSC. The platform consists of a Xilinx ML605 Virtex-6 FPGA board, an Analog Devices FMCOMMS1-EBZ RF transceiver board, and an Embedded PC (Axiomtek eBox 620-110-FL) running the Ubuntu 12.4 operating system. Figure 1 shows the RIACS platform hardware. The result of this development is a very low cost STRS compliant platform that can be used for waveform developments for multiple applications.The purpose of this document is to describe how to develop a new waveform using the RIACS platform and the Very High Speed Integrated Circuits (VHSIC) Hardware Description Language (VHDL) FPGA wrapper code and the STRS implementation on the Axiomtek processor.
DITDOS: A set of design specifications for distributed data inventories
NASA Technical Reports Server (NTRS)
King, T. A.; Walker, R. J.; Joy, S. P.
1995-01-01
The analysis of space science data often requires researchers to work with many different types of data. For instance, correlative analysis can require data from multiple instruments on a single spacecraft, multiple spacecraft, and ground-based data. Typically, data from each source are available in a different format and have been written on a different type of computer, and so much effort must be spent to read the data and convert it to the computer and format that the researchers use in their analysis. The large and ever-growing amount of data and the large investment by the scientific community in software that require a specific data format make using standard data formats impractical. A format-independent approach to accessing and analyzing disparate data is key to being able to deliver data to a diverse community in a timely fashion. The system in use at the Planetary Plasma Interactions (PPI) node of the NASA Planetary Data System (PDS) is based on the object-oriented Distributed Inventory Tracking and Data Ordering Specification (DITDOS), which describes data inventories in a storage independent way. The specifications have been designed to make it possible to build DITDOS compliant inventories that can exist on portable media such as CD-ROM's. The portable media can be moved within a system, or from system to system, and still be used without modification. Several applications have been developed to work with DITDOS compliant data holdings. One is a windows-based client/server application, which helps guide the user in the selection of data. A user can select a data base, then a data set, then a specific data file, and then either order the data and receive it immediately if it is online or request that it be brought online if it is not. A user can also view data by any of the supported methods. DITDOS makes it possible to use already existing applications for data-specific actions, and this is done whenever possible. Another application is a stand-alone tool to assist in the extraction of data from portable media, such as CD-ROM's. In addition to the applications, there is a set of libraries that can facilitate building new DITDOS compliant applications.
Hamilton, Caroline; D'Arcy, Shona; Pearlmutter, Barak A; Crispino, Gloria; Lalor, Edmund C; Conlon, Brendan J
2016-12-01
Tinnitus is the perception of sound in the absence of an external auditory stimulus. It is widely believed that tinnitus, in patients with associated hearing loss, is a neurological phenomenon primarily affecting the central auditory structures. However, there is growing evidence for the involvement of the somatosensory system in this form of tinnitus. For this reason it has been suggested that the condition may be amenable to bi-modal stimulation of the auditory and somatosensory systems. We conducted a pilot study to investigate the feasibility and safety of a device that delivers simultaneous auditory and somatosensory stimulation to treat the symptoms of chronic tinnitus. A cohort of 54 patients used the stimulation device for 10 weeks. Auditory stimulation was delivered via headphones and somatosensory stimulation was delivered via electrical stimulation of the tongue. Patient usage, logged by the device, was used to classify patients as compliant or noncompliant. Safety was assessed by reported adverse events and changes in tinnitus outcome measures. Response to treatment was assessed using tinnitus outcome measures: Minimum Masking Level (MML), Tinnitus Loudness Matching (TLM), and Tinnitus Handicap Inventory (THI). The device was well tolerated by patients and no adverse events or serious difficulties using the device were reported. Overall, 68% of patients met the defined compliance threshold. Compliant patients (N = 30) demonstrated statistically significant improvements in mean outcome measures after 10 weeks of treatment: THI (-11.7 pts, p < 0.001), TLM (-7.5dB, p < 0.001), and MML (-9.7dB, p < 0.001). The noncompliant group (N = 14) demonstrated no statistical improvements. This study demonstrates the feasibility and safety of a new bi-modal stimulation device and supports the potential efficacy of this new treatment for tinnitus. © 2016 Neuromod Devices Ltd. Neuromodulation: Technology at the Neural Interface published by Wiley Periodicals, Inc. on behalf of International Neuromodulation Society.
Full-scale regional exercises: closing the gaps in disaster preparedness.
Klima, David A; Seiler, Sarah H; Peterson, Jeff B; Christmas, A Britton; Green, John M; Fleming, Greg; Thomason, Michael H; Sing, Ronald F
2012-09-01
Man-made (9/11) and natural (Hurricane Katrina) disasters have enlightened the medical community regarding the importance of disaster preparedness. In response to Joint Commission requirements, medical centers should have established protocols in place to respond to such events. We examined a full-scale regional exercise (FSRE) to identify gaps in logistics and operations during a simulated mass casualty incident. A multiagency, multijurisdictional, multidisciplinary exercise (FSRE) included 16 area hospitals and one American College of Surgeons-verified Level I trauma center (TC). The scenario simulated a train derailment and chemical spill 20 miles from the TC using 281 moulaged volunteers. Third-party contracted evaluators assessed each hospital in five areas: communications, command structure, decontamination, staffing, and patient tracking. Further analysis examined logistic and operational deficiencies. None of the 16 hospitals were compliant in all five areas. Mean hospital compliance was 1.9 (± 0.9 SD) areas. One hospital, unable to participate because of an air conditioner outage, was deemed 0% compliant. The most common deficiency was communications (15 of 16 hospitals [94%]; State Medical Asset Resource Tracking Tool system deficiencies, lack of working knowledge of Voice Interoperability Plan for Emergency Responders radio system) followed by deficient decontamination in 12 (75%). Other deficiencies included inadequate staffing based on predetermined protocols in 10 hospitals (63%), suboptimal command structure in 9 (56%), and patient tracking deficiencies in 5 (31%). An additional 11 operational and 5 logistic failures were identified. The TC showed an appropriate command structure but was deficient in four of five categories, with understaffing and a decontamination leak into the emergency department, which required diversion of 70 patients. Communication remains a significant gap in the mass casualty scenario 10 years after 9/11. Our findings demonstrate that tabletop exercises are inadequate to expose operational and logistic gaps in disaster response. FSREs should be routinely performed to adequately prepare for catastrophic events.
Eboreime, Ejemai Amaize; Abimbola, Seye; Obi, Felix Abrahams; Ebirim, Obinna; Olubajo, Olalekan; Eyles, John; Nxumalo, Nonhlanhla Lynette; Mambulu, Faith Nankasa
2017-03-21
Policy making, translation and implementation in politically and administratively decentralized systems can be challenging. Beyond the mere sub-national acceptance of national initiatives, adherence to policy implementation processes is often poor, particularly in low and middle-income countries. In this study, we explore the implementation fidelity of integrated PHC governance policy in Nigeria's decentralized governance system and its implications on closing implementation gaps with respect to other top-down health policies and initiatives. Having engaged policy makers, we identified 9 core components of the policy (Governance, Legislation, Minimum Service Package, Repositioning, Systems Development, Operational Guidelines, Human Resources, Funding Structure, and Office Establishment). We evaluated the level and pattern of implementation at state level as compared to the national guidelines using a scorecard approach. Contrary to national government's assessment of level of compliance, we found that sub-national governments exercised significant discretion with respect to the implementation of core components of the policy. Whereas 35 and 32% of states fully met national criteria for the structural domains of "Office Establishment" and Legislation" respectively, no state was fully compliant to "Human Resource Management" and "Funding" requirements, which are more indicative of functionality. The pattern of implementation suggests that, rather than implementing to improve outcomes, state governments may be more interested in executing low hanging fruits in order to access national incentives. Our study highlights the importance of evaluating implementation fidelity in providing evidence of implementation gaps towards improving policy execution, particularly in decentralized health systems. This approach will help national policy makers identify more effective ways of supporting lower tiers of governance towards improvement of health systems and outcomes.
Henley, David E; Buchanan, Fiona; Gibson, Rosemary; Douthwaite, Jennie A; Wood, Susan A; Woltersdorf, Wolfram W; Catterall, James R; Lightman, Stafford L
2009-10-01
Apelin is a peptide hormone with cardiovascular and glucose homeostasis properties, and obstructive sleep apnea (OSA) is complicated by cardiovascular and metabolic comorbidities. Plasma apelin has not been previously assessed in OSA. We investigated the response of plasma apelin to a 2-h 75 g oral glucose tolerance test (OGTT) and the effect of 3 months compliant continuous positive airway pressure (CPAP) therapy in 15 obese males with newly diagnosed OSA. Plasma apelin and serum cortisol were recorded 10 minutely, while serum insulin and glucose were measured 30 minutely. Ten subjects had plasma apelin measured at intervals across a 24-h period to investigate for circadian variation in apelin levels, and this was repeated following 3 months compliant CPAP therapy. Fasting (0.342+/-0.038 vs 0.288+/-0.024 ng/ml, P=0.04), 30 min (0.399+/-0.035 vs 0.312+/-0.036 ng/ml, P=0.007) and 120 min (0.402+/-0.030 vs 0.259+/-0.024 ng/ml, P<0.001) apelin levels were reduced following CPAP. The area under curve for apelin OGTT response was lower post-CPAP (44.1+/-3.3 vs 35.8+/-2.3 ng/ml per min, P<0.001). Mean OGTT apelin levels showed a significant treatment effect (P=0.006) and a time effect (P<0.001), and the effect of time was different pre- versus post-CPAP (P=0.005). No significant variability in apelin levels existed across the 24-h period at diagnosis. Lower levels were evident overnight following treatment (P=0.004). Improvements in insulin and glucose parameters and reduced cortisol levels were found post-CPAP. In summary, untreated OSA was associated with elevated plasma apelin levels, altered apelin secretory dynamics in response to oral glucose and lack of an apparent circadian variability, which was restored following CPAP.
40 CFR 80.1342 - What compliance options are available to small refiners under this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline... which it will produce compliant gasoline. (2)(i) Defer meeting the standard specified in § 80.1230(b... produce compliant gasoline. (b) Any refiner that makes an election under paragraphs (a)(1) or (a)(2) of...
Barrett, Lee B; Hanks, Tom; Zubeldia, Kepa; Cramer, Richard
The deadlines are looming for compliance with the transaction and code set requirements set forth in the Health Insurance Portability and Accountability Act of 1996 (HIPAA). If your hospital filed for an extension in October 2002, you need to begin testing transactions by April 2003 and sending transactions by October 2003. But don't rely on your technology vendors to give you the ability to send compliant transactions. While vendors can provide the correct computer data format, they can't gather the correct information. If you can't send a compliant transaction, the Centers for Medicare and Medicaid Services could reject your claims, drying up a big percentage of your cash flow.
NASA Technical Reports Server (NTRS)
Kerley, James J. (Inventor); Eklund, Wayne D. (Inventor); Crane, J. Allen (Inventor)
1992-01-01
A compliant walker is provided for humans having limited use of their legs and lower back. It includes an upright wheel frame which at least partially surrounds an upright user wearing a partial body harness. It is attached to the frame by means of cable compliant apparatus consisting of sets of cable segments and angle bracket members connected between opposite side members of the frame and adjacent side portions of the harness. Novelty is believed to exist in the combination of a wheeled frame including a side support structure, a body harness, and compliance means connecting the body harness to the side support structure for flexibility holding and supporting a person in a substantially upright position when the user sags in the frame when taking weight off the lower extremities.
Myths and Truths of Nitinol Mechanics: Elasticity and Tension-Compression Asymmetry
NASA Astrophysics Data System (ADS)
Bucsek, Ashley N.; Paranjape, Harshad M.; Stebner, Aaron P.
2016-09-01
Two prevalent myths of Nitinol mechanics are examined: (1) Martensite is more compliant than austenite; (2) Texture-free Nitinol polycrystals do not exhibit tension-compression asymmetry. By reviewing existing literature, the following truths are revealed: (1) Martensite crystals may be more compliant, equally stiff, or stiffer than austenite crystals, depending on the orientation of the applied load. The Young's Modulus of polycrystalline Nitinol is not a fixed number—it changes with both processing and in operando deformations. Nitinol martensite prefers to behave stiffer under compressive loads and more compliant under tensile loads. (2) Inelastic Nitinol martensite deformation in and of itself is asymmetric, even for texture-free polycrystals. Texture-free Nitinol polycrystals also exhibit tension-compression transformation asymmetry.
2011 Information Systems Summit 2 Held in Baltimore, Maryland on April 4-6, 2011
2011-04-04
to automate. Some criteria that should be considered: – Are the tests easy to automate? What makes a test easy to automate is the ability to script...ANSI-748-B defines 32 criteria needs for a FAR/DFAR compliant Earned Value Management System. These criteria address 5 areas of Earned Value...are the basis of Increasing the Probability of Success of any program. But there are 11 critical criteria that must be present not matter what
2008-06-01
Management and Budget, Paperwork Reduction Project (0704-0188) Washington DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE June 2008...We introduce World Wide Web Consortium (W3C) compliant services into the planning and battle management processes where a computer can be more...which the software services comprising the command, control, and battle management (C2BM) element of the BMD system need to operate within hard real
NASA Astrophysics Data System (ADS)
Silva, Augusto F. d.; Costa, Carlos; Abrantes, Pedro; Gama, Vasco; Den Boer, Ad
1998-07-01
This paper describes an integrated system designed to provide efficient means for DICOM compliant cardiac imaging archival, transmission and visualization based on a communications backbone matching recent enabling telematic technologies like Asynchronous Transfer Mode (ATM) and switched Local Area Networks (LANs). Within a distributed client-server framework, the system was conceived on a modality based bottom-up approach, aiming ultrafast access to short term archives and seamless retrieval of cardiac video sequences throughout review stations located at the outpatient referral rooms, intensive and intermediate care units and operating theaters.
Benchmarking multimedia performance
NASA Astrophysics Data System (ADS)
Zandi, Ahmad; Sudharsanan, Subramania I.
1998-03-01
With the introduction of faster processors and special instruction sets tailored to multimedia, a number of exciting applications are now feasible on the desktops. Among these is the DVD playback consisting, among other things, of MPEG-2 video and Dolby digital audio or MPEG-2 audio. Other multimedia applications such as video conferencing and speech recognition are also becoming popular on computer systems. In view of this tremendous interest in multimedia, a group of major computer companies have formed, Multimedia Benchmarks Committee as part of Standard Performance Evaluation Corp. to address the performance issues of multimedia applications. The approach is multi-tiered with three tiers of fidelity from minimal to full compliant. In each case the fidelity of the bitstream reconstruction as well as quality of the video or audio output are measured and the system is classified accordingly. At the next step the performance of the system is measured. In many multimedia applications such as the DVD playback the application needs to be run at a specific rate. In this case the measurement of the excess processing power, makes all the difference. All these make a system level, application based, multimedia benchmark very challenging. Several ideas and methodologies for each aspect of the problems will be presented and analyzed.
Development of surface coatings for air-lubricated, compliant journal bearings to 650 C
NASA Technical Reports Server (NTRS)
Bhushan, B.; Gray, S.
1978-01-01
Surface coatings for an air-lubricated, compliant journal for an automotive gas turbine engine were tested to find those capable of withstanding temperatures of either 540 C (1000 F) or 650 C (1200 F). Also, the coatings have to be capable of surviving the start-stop sliding contact cycles prior to rotor lift-off and at touchdown. Selected coating combinations were tested in start-stop tests at 14 kPa (2 psi) loading for 2000 cycles at room and maximum temperatures. Specific coating recommendations are: Cdo and graphite on foil versus chrome carbide on journal up to 370 C (700 F); NASA PS-120 (Tribaloy 400, silver, and CaF2) on journal versus uncoated foil up to 540 C (1000 F); and chemically adherent Cr2O3 on journal and foil up to 650 C (1200 F). The chemically adherent Cr2O3 coating system was further tested successfully at 35 kPa (5 psi) loading for 2000 start-stop cycles.
Beltrame, Luca; Calura, Enrica; Popovici, Razvan R; Rizzetto, Lisa; Guedez, Damariz Rivero; Donato, Michele; Romualdi, Chiara; Draghici, Sorin; Cavalieri, Duccio
2011-08-01
Many models and analysis of signaling pathways have been proposed. However, neither of them takes into account that a biological pathway is not a fixed system, but instead it depends on the organism, tissue and cell type as well as on physiological, pathological and experimental conditions. The Biological Connection Markup Language (BCML) is a format to describe, annotate and visualize pathways. BCML is able to store multiple information, permitting a selective view of the pathway as it exists and/or behave in specific organisms, tissues and cells. Furthermore, BCML can be automatically converted into data formats suitable for analysis and into a fully SBGN-compliant graphical representation, making it an important tool that can be used by both computational biologists and 'wet lab' scientists. The XML schema and the BCML software suite are freely available under the LGPL for download at http://bcml.dc-atlas.net. They are implemented in Java and supported on MS Windows, Linux and OS X.
Di Bartolo, Paolo; Nicolucci, Antonio; Cherubini, Valentino; Iafusco, Diario; Scardapane, Marco; Rossi, Maria Chiara
2017-04-01
To compare iBGStar™ + DMApp (experimental meter + telemedicine system) (iBGStar) with a traditional glucose meter (Control) in type 1 diabetes adolescents/young adults. i-NewTrend was a multicenter, open-label, randomized trial involving subjects aged 14-24 years, on basal-bolus insulin, HbA1c ≥ 8.0%, and poorly compliant with SMBG (i.e., <30% of the recommended frequency). Primary end points were change in HbA1c and achievement of compliance with SMBG (≥30% of the recommended frequency) after 6 months. Quality of life was also evaluated. A post-trial observational phase was conducted, where both groups used the experimental device. Of 182 randomized patients (51.1% male; age 17.7 ± 3.0 years; diabetes duration 8.8 ± 4.7 years; HbA1c levels 10.0% ± 1.4), 92 were allocated to iBGStar and 90 to Control; 6.5% in iBGStar and 8.9% in Control dropped-out. After 6 months, HbA1c changes (±SE) were -0.44% ± 0.13 in iBGStar and -0.32% ± 0.13 in Control (p = 0.51). In the post-trial phase, HbA1c changes from 6 months (±SE) were -0.07% ± 0.14 in iBGStar and -0.31% ± 0.14 in Control (p = 0.24). Compliance end point was reached by 53.6% in iBGStar and 55.0% in Control (p = 0.86). Mean daily SMBG measurements increased from 1.1 to 2.3 in both groups without worsening quality of life. Compliant subjects showed a greater reduction in HbA1c levels (-0.60% ± 0.23 in iBGStar; -0.41% ± 0.21 in Control; p = 0.31). Within iBGStar group, telemedicine users (38.0%) reduced HbA1c by -0.58 ± 0.18. iBGStar was not superior to the traditional meter. Irrespective of the strategy, increasing from 1 to 2 SMBG tests/day was associated with HbA1c reduction in both groups, without pharmacologic interventions. Identifying new technologies effective and acceptable to patients is an option to improve adherence to diabetes care. The trial was registered at ClinicalTrials.gov (registration number NCT02073188).
Jelacic, Srdjan; Bowdle, Andrew; Nair, Bala G; Kusulos, Dolly; Bower, Lynnette; Togashi, Kei
2015-08-01
Many anesthetic drug errors result from vial or syringe swaps. Scanning the barcodes on vials before drug preparation, creating syringe labels that include barcodes, and scanning the syringe label barcodes before drug administration may help to prevent errors. In contrast, making syringe labels by hand that comply with the recommendations of regulatory agencies and standards-setting bodies is tedious and time consuming. A computerized system that uses vial barcodes and generates barcoded syringe labels could address both safety issues and labeling recommendations. We measured compliance of syringe labels in multiple operating rooms (ORs) with the recommendations of regulatory agencies and standards-setting bodies before and after the introduction of the Codonics Safe Label System (SLS). The Codonics SLS was then combined with Smart Anesthesia Manager software to create an anesthesia barcode drug administration system, which allowed us to measure the rate of scanning syringe label barcodes at the time of drug administration in 2 cardiothoracic ORs before and after introducing a coffee card incentive. Twelve attending cardiothoracic anesthesiologists and the OR satellite pharmacy participated. The use of the Codonics SLS drug labeling system resulted in >75% compliant syringe labels (95% confidence interval, 75%-98%). All syringe labels made using the Codonics SLS system were compliant. The average rate of scanning barcodes on syringe labels using Smart Anesthesia Manager was 25% (730 of 2976) over 13 weeks but increased to 58% (956 of 1645) over 8 weeks after introduction of a simple (coffee card) incentive (P < 0.001). An anesthesia barcode drug administration system resulted in a moderate rate of scanning syringe label barcodes at the time of drug administration. Further, adaptation of the system will be required to achieve a higher utilization rate.
Brown, Lucy L.; Acevedo, Bianca; Fisher, Helen E.
2013-01-01
Four suites of behavioral traits have been associated with four broad neural systems: the 1) dopamine and related norepinephrine system; 2) serotonin; 3) testosterone; 4) and estrogen and oxytocin system. A 56-item questionnaire, the Fisher Temperament Inventory (FTI), was developed to define four temperament dimensions associated with these behavioral traits and neural systems. The questionnaire has been used to suggest romantic partner compatibility. The dimensions were named: Curious/Energetic; Cautious/Social Norm Compliant; Analytical/Tough-minded; and Prosocial/Empathetic. For the present study, the FTI was administered to participants in two functional magnetic resonance imaging studies that elicited feelings of love and attachment, near-universal human experiences. Scores for the Curious/Energetic dimension co-varied with activation in a region of the substantia nigra, consistent with the prediction that this dimension reflects activity in the dopamine system. Scores for the Cautious/Social Norm Compliant dimension correlated with activation in the ventrolateral prefrontal cortex in regions associated with social norm compliance, a trait linked with the serotonin system. Scores on the Analytical/Tough-minded scale co-varied with activity in regions of the occipital and parietal cortices associated with visual acuity and mathematical thinking, traits linked with testosterone. Also, testosterone contributes to brain architecture in these areas. Scores on the Prosocial/Empathetic scale correlated with activity in regions of the inferior frontal gyrus, anterior insula and fusiform gyrus. These are regions associated with mirror neurons or empathy, a trait linked with the estrogen/oxytocin system, and where estrogen contributes to brain architecture. These findings, replicated across two studies, suggest that the FTI measures influences of four broad neural systems, and that these temperament dimensions and neural systems could constitute foundational mechanisms in personality structure and play a role in romantic partnerships. PMID:24236043
Brown, Lucy L; Acevedo, Bianca; Fisher, Helen E
2013-01-01
Four suites of behavioral traits have been associated with four broad neural systems: the 1) dopamine and related norepinephrine system; 2) serotonin; 3) testosterone; 4) and estrogen and oxytocin system. A 56-item questionnaire, the Fisher Temperament Inventory (FTI), was developed to define four temperament dimensions associated with these behavioral traits and neural systems. The questionnaire has been used to suggest romantic partner compatibility. The dimensions were named: Curious/Energetic; Cautious/Social Norm Compliant; Analytical/Tough-minded; and Prosocial/Empathetic. For the present study, the FTI was administered to participants in two functional magnetic resonance imaging studies that elicited feelings of love and attachment, near-universal human experiences. Scores for the Curious/Energetic dimension co-varied with activation in a region of the substantia nigra, consistent with the prediction that this dimension reflects activity in the dopamine system. Scores for the Cautious/Social Norm Compliant dimension correlated with activation in the ventrolateral prefrontal cortex in regions associated with social norm compliance, a trait linked with the serotonin system. Scores on the Analytical/Tough-minded scale co-varied with activity in regions of the occipital and parietal cortices associated with visual acuity and mathematical thinking, traits linked with testosterone. Also, testosterone contributes to brain architecture in these areas. Scores on the Prosocial/Empathetic scale correlated with activity in regions of the inferior frontal gyrus, anterior insula and fusiform gyrus. These are regions associated with mirror neurons or empathy, a trait linked with the estrogen/oxytocin system, and where estrogen contributes to brain architecture. These findings, replicated across two studies, suggest that the FTI measures influences of four broad neural systems, and that these temperament dimensions and neural systems could constitute foundational mechanisms in personality structure and play a role in romantic partnerships.
Field-programmable gate array implementation of an all-digital IEEE 802.15.4-compliant transceiver
NASA Astrophysics Data System (ADS)
Cornetta, Gianluca; Touhafi, Abdellah; Santos, David J.; Vázquez, José M.
2010-12-01
An architecture for a low-cost, low-complexity digital transceiver is presented in this article. The proposed architecture targets the IEEE 802.15.4 standard for short-range wireless personal area networks and has been implemented as a synthesisable VHDL register transfer level description. The system has been evaluated and tested using a Xilinx 90 nm Virtex-4 field-programmable gate array as the target technology. Bit error rate (BER) and error vector magnitude (EVM) have been used as the figures of merit for modem performance. Simulations show that the recommended minimum BER is achieved at E b/N 0 = 8.7 dB, whereas the EVM is 19.5%. The implemented device occupies 10% of the target FPGA and has a normalised maximum power consumption of 44 mW in transmit mode and 53 mW in receiver mode.
Smart grid as a service: a discussion on design issues.
Chao, Hung-Lin; Tsai, Chen-Chou; Hsiung, Pao-Ann; Chou, I-Hsin
2014-01-01
Smart grid allows the integration of distributed renewable energy resources into the conventional electricity distribution power grid such that the goals of reduction in power cost and in environment pollution can be met through an intelligent and efficient matching between power generators and power loads. Currently, this rapidly developing infrastructure is not as "smart" as it should be because of the lack of a flexible, scalable, and adaptive structure. As a solution, this work proposes smart grid as a service (SGaaS), which not only allows a smart grid to be composed out of basic services, but also allows power users to choose between different services based on their own requirements. The two important issues of service-level agreements and composition of services are also addressed in this work. Finally, we give the details of how SGaaS can be implemented using a FIPA-compliant JADE multiagent system.
Smart Grid as a Service: A Discussion on Design Issues
Tsai, Chen-Chou; Chou, I-Hsin
2014-01-01
Smart grid allows the integration of distributed renewable energy resources into the conventional electricity distribution power grid such that the goals of reduction in power cost and in environment pollution can be met through an intelligent and efficient matching between power generators and power loads. Currently, this rapidly developing infrastructure is not as “smart” as it should be because of the lack of a flexible, scalable, and adaptive structure. As a solution, this work proposes smart grid as a service (SGaaS), which not only allows a smart grid to be composed out of basic services, but also allows power users to choose between different services based on their own requirements. The two important issues of service-level agreements and composition of services are also addressed in this work. Finally, we give the details of how SGaaS can be implemented using a FIPA-compliant JADE multiagent system. PMID:25243214
Remote physiotherapy monitoring using the novel D+R Therapy iPhone application.
Vaish, Abhishek; Ahmed, Saif; Shetty, Anan
2017-01-01
Patient compliance to physiotherapy after surgical intervention is key to optimal functional outcome. This has been recognised by published literature over a number of decades. Improving and monitoring patient compliance remains a challenge. This paper explores the use of a website linked iPhone application that may be used to address this issue. The purpose of this case study was to assess if the D+R Therapy application was of benefit to a patient and to assess the advantages and disadvantages of such a system. One patient who underwent knee cartilage resurfacing surgery was followed up in the post-operative period. The D+R Therapy platform may provide a timely and cost effective method of managing patients undergoing musculoskeletal physiotherapy. Costs may be reduced by exploiting the hardware patients already own, and identifying non-compliant patients who may be of interest to both healthcare providers and insurers. Level IV.
Burgarella, Sarah; Cattaneo, Dario; Pinciroli, Francesco; Masseroli, Marco
2005-12-01
Improvements of bio-nano-technologies and biomolecular techniques have led to increasing production of high-throughput experimental data. Spotted cDNA microarray is one of the most diffuse technologies, used in single research laboratories and in biotechnology service facilities. Although they are routinely performed, spotted microarray experiments are complex procedures entailing several experimental steps and actors with different technical skills and roles. During an experiment, involved actors, who can also be located in a distance, need to access and share specific experiment information according to their roles. Furthermore, complete information describing all experimental steps must be orderly collected to allow subsequent correct interpretation of experimental results. We developed MicroGen, a web system for managing information and workflow in the production pipeline of spotted microarray experiments. It is constituted of a core multi-database system able to store all data completely characterizing different spotted microarray experiments according to the Minimum Information About Microarray Experiments (MIAME) standard, and of an intuitive and user-friendly web interface able to support the collaborative work required among multidisciplinary actors and roles involved in spotted microarray experiment production. MicroGen supports six types of user roles: the researcher who designs and requests the experiment, the spotting operator, the hybridisation operator, the image processing operator, the system administrator, and the generic public user who can access the unrestricted part of the system to get information about MicroGen services. MicroGen represents a MIAME compliant information system that enables managing workflow and supporting collaborative work in spotted microarray experiment production.
Hillyer, Margot M; Finch, Lauren E; Cerel, Alisha S; Dattelbaum, Jonathan D; Leopold, Michael C
2014-08-01
A wide spectrum and large number of children's toys and toy jewelry items were purchased from both bargain and retail vendors and analyzed for arsenic, cadmium, and lead metal content using multiple analytical techniques, including flame and furnace atomic absorption spectroscopy as well as X-ray fluorescence spectroscopy. Particularly dangerous for young children, metal concentrations in toys/toy jewelry were assessed for compliance with current Consumer Safety Product Commission (CPSC) regulations (F963-11). A conservative metric involving multiple analytical techniques was used to categorize compliance: one technique confirmation of metal in excess of CPSC limits indicated a "suspect" item while confirmation on two different techniques warranted a non-compliant designation. Sample matrix-based standard addition provided additional confirmation of non-compliant and suspect products. Results suggest that origin of purchase, rather than cost, is a significant factor in the risk assessment of these materials with 57% of toys/toy jewelry items from bargain stores non-compliant or suspect compared to only 15% from retail outlets and 13% if only low cost items from the retail stores are compared. While jewelry was found to be the most problematic product (73% of non-compliant/suspect samples), lead (45%) and arsenic (76%) were the most dominant toxins found in non-compliant/suspect samples. Using the greater Richmond area as a model, the discrepancy between bargain and retail children's products, along with growing numbers of bargain stores in low-income and urban areas, exemplifies an emerging socioeconomic public health issue. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rule modification in junior sport: Does it create differences in player movement?
Gastin, Paul B; Allan, Matthew D; Bellesini, Kylie; Spittle, Michael
2017-10-01
To determine the effects of rule modification on player movement during matchplay in junior Australian football (AF). Quasi-experimental study design. Time-motion analysis was used to record variables pertaining to player movement including total distance covered, high-speed running (HSR) distance (>14.4km/h) and HSR efforts. GPS data obtained from 145 players (7-12 years) were analysed across four junior AF leagues and three age group combinations (U8/U9, U9/U10 and U11/U12). The four leagues were collapsed into two separate conditions (compliant and non-compliant) based on their adherence to a modified junior sport policy. To control for the influence of age and physical maturity, a secondary analysis was performed on an adequately matched U8 subset of data (n=48). Significant differences (p<0.05) were found between compliant and non-compliant leagues for age and all player movement variables, with participants in the compliant leagues achieving less player movement. Significant differences were also evident between conditions in the U8 subset in total and relative distance and HSR efforts, with moderate to very large differences (29-60%) observed for all player movement variables. Rule modifications limits the extent and intensity of player movement in junior AF compared to standard playing conditions. The unintended effect of reduced physical activity with rule modifications should be compensated for with additional activities wherever possible. League administrators and policy makers should consider the objectives of rule modifications and weigh up both positive and negative outcomes. Copyright © 2017. Published by Elsevier Ltd.
40 CFR 63.4100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.4091(a... coating operation(s) for which you use the emission rate with add-on controls option, as specified in § 63... operating limits for emission capture systems and add-on control devices required by § 63.4092 at all times...
40 CFR 63.4700 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.4691(a... coating operation(s) for which you use the emission rate with add-on controls option, as specified in § 63... systems and add-on control devices required by § 63.4692 at all times, except during periods of SSM, and...
40 CFR 63.4100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.4091(a... coating operation(s) for which you use the emission rate with add-on controls option, as specified in § 63... operating limits for emission capture systems and add-on control devices required by § 63.4092 at all times...
40 CFR 63.4700 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.4691(a... coating operation(s) for which you use the emission rate with add-on controls option, as specified in § 63... systems and add-on control devices required by § 63.4692 at all times, except during periods of SSM, and...
40 CFR 63.3500 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.3491(a... operation(s) for which you use the emission rate with add-on controls option, as specified in § 63.3491(c... capture systems and add-on control devices required by § 63.3492 at all times, except for those for which...
40 CFR 63.3500 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.3491(a... operation(s) for which you use the emission rate with add-on controls option, as specified in § 63.3491(c... capture systems and add-on control devices required by § 63.3492 at all times, except for those for which...
40 CFR 63.4100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.4091(a... coating operation(s) for which you use the emission rate with add-on controls option, as specified in § 63... operating limits for emission capture systems and add-on control devices required by § 63.4092 at all times...
40 CFR 63.3500 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.3491(a... operation(s) for which you use the emission rate with add-on controls option, as specified in § 63.3491(c... capture systems and add-on control devices required by § 63.3492 at all times, except for those for which...
40 CFR 63.4700 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... compliant material option or the emission rate without add-on controls option, as specified in § 63.4691(a... coating operation(s) for which you use the emission rate with add-on controls option, as specified in § 63... systems and add-on control devices required by § 63.4692 at all times, except during periods of SSM, and...
NASA Technical Reports Server (NTRS)
Fischer, M. C.; Ash, R. L.
1974-01-01
Four main concepts which have significantly reduced skin friction in experimental studies are discussed; suction, gaseous injection, particle additives, and compliant wall. It is considered possible that each of these concepts could be developed and applied in viable skin friction reduction systems for aircraft application. Problem areas with each concept are discussed, and recommendations for future studies are made.
Bourgeois, Richard Scott [Albany, NY; Gudlavalleti, Sauri [Albany, NY
2009-12-15
A fuel cell assembly comprising at least one metallic component, at least one ceramic component and a structure disposed between the metallic component and the ceramic component. The structure is configured to have a lower stiffness compared to at least one of the metallic component and the ceramic component, to accommodate a difference in strain between the metallic component and the ceramic component of the fuel cell assembly.
Low-cost space flight for attached payloads
NASA Astrophysics Data System (ADS)
Perkins, Frederick W.
1991-07-01
An important addition to the emerging commercial space sector is Standard Space Platforms Corporation's comprehensive low-cost flight service delivery system for small and developmental payloads. Standard provides a privately funded, proprietary, value-added transportation service which dramatically reduces cost and program duration for compliant payloads. It also provides a business-to-business service which is compatible with business investment decision timing and technology development cycles.
Copper nanoparticles impinging on a curved channel with compliant walls and peristalsis
NASA Astrophysics Data System (ADS)
Akbar, Noreen Sher; Maraj, E. N.; Butt, Adil Wahid
2014-08-01
In the present article peristaltic transport of copper nanofluids in a curved channel with compliant walls is analytically studied. The mathematical analysis is carried out under the low Reynolds number and long wavelenght approximation. The exact solutions are computed for fluid velocity and temperature profile. The effect of meaningful parameters are shown graphically in the last section.
Training Children with Autism Spectrum Disorders to Be Compliant with a Physical Exam
ERIC Educational Resources Information Center
Cuvo, Anthony J.; Reagan, Amanda Law; Ackerlund, Julie; Huckfeldt, Rachel; Kelly, Cheri
2010-01-01
The purpose of this study was to train children with autism spectrum disorders to be compliant with a 10-component physical examination. After a physician assistant administered an exam pretest, noncompliance on steps of the exam were considered with respect to a skill deficit and escape from aversive stimuli. A package of training procedures was…
Case study: physicians develop results viewer amid Y2K commotion.
Wurz, J A; Manis, J L
2000-01-01
Amid a flurry of Y2K preparations, which included converting patient accounting and order processing systems for six of its eight hospitals, Advocate Health Care needed to address physician complaints that the compliant software was awkward. By partnering with physicians, information systems (IS) rapidly developed a solution that met both the need for compliance and the demand for an easy-to-use, patient-centric clinical information system. A robust, browser-based results viewer provides physician access to information from patient accounting, order processing, and several clinical ancillary systems. Advocate anticipates greater challenges as the system is promoted to other sites and clinical communities.
Time-resolved PIV measurements of the flow field in a stenosed, compliant arterial model
NASA Astrophysics Data System (ADS)
Geoghegan, P. H.; Buchmann, N. A.; Soria, J.; Jermy, M. C.
2013-05-01
Compliant (flexible) structures play an important role in several biological flows including the lungs, heart and arteries. Coronary heart disease is caused by a constriction in the artery due to a build-up of atherosclerotic plaque. This plaque is also of major concern in the carotid artery which supplies blood to the brain. Blood flow within these arteries is strongly influenced by the movement of the wall. To study these problems experimentally in vitro, especially using flow visualisation techniques, can be expensive due to the high-intensity and high-repetition rate light sources required. In this work, time-resolved particle image velocimetry using a relatively low-cost light-emitting diode illumination system was applied to the study of a compliant flow phantom representing a stenosed (constricted) carotid artery experiencing a physiologically realistic flow wave. Dynamic similarity between in vivo and in vitro conditions was ensured in phantom construction by matching the distensibility and the elastic wave propagation wavelength and in the fluid system through matching Reynolds ( Re) and Womersley number ( α) with a maximum, minimum and mean Re of 939, 379 and 632, respectively, and a α of 4.54. The stenosis had a symmetric constriction of 50 % by diameter (75 % by area). Once the flow rate reached a critical value, Kelvin-Helmholtz instabilities were observed to occur in the shear layer between the main jet exiting the stenosis and a reverse flow region that occurred at a radial distance of 0.34 D from the axis of symmetry in the region on interest 0-2.5 D longitudinally downstream from the stenosis exit. The instability had an axis-symmetric nature, but as peak flow rate was approached this symmetry breaks down producing instability in the flow field. The characteristics of the vortex train were sensitive not only to the instantaneous flow rate, but also to whether the flow was accelerating or decelerating globally.
Alekel, D. Lee; Genschel, Ulrike; Koehler, Kenneth J; Hofmann, Heike; Van Loan, Marta D; Beer, Bonnie S.; Hanson, Laura N; Peterson, Charles T; Kurzer, Mindy S
2014-01-01
Objectives To assess the overall safety and potential endometrial stimulation of soy isoflavone tablets consumed (3-year) by postmenopausal women. To determine the endometrial thickness response-to-treatment among compliant women, taking into account hormone concentrations and other hypothesized modifying factors. Methods We randomized healthy postmenopausal women (45.8–65.0 years) to placebo control or two doses (80 or 120 mg/day) of soy isoflavones at two sites. We used intent-to-treat (N=224) and compliant (>95%; N=208) analyses to assess circulating hormone concentrations, adverse events, and endometrial thickness (via transvaginal ultrasound). Results Median values for endometrial thickness (mm) declined from baseline through 36 mo. Nonparametric ANOVA for treatment differences among groups showed no differences in absolute (or percentage change) endometrial thickness at any time point (Chi-Square p-values ranged from 0.12–0.69), nor in circulating hormones at any time point. A greater number of adverse events for the genitourinary system (p=0.005) was noted in the 80 compared to 120 mg/day group, whereas other systems showed no treatment effects. The model predicting the endometrial thickness response-(using natural logarithm)-to-treatment with compliant women across time points was significant (p<0.0001), indicating that estrogen exposure (p=0.0013), plasma 17 β-estradiol (p=0.0086), and alcohol intake (p=0.023) contributed significantly to the response. Neither the 80 (p=0.57) nor 120 (p=0.43) mg/day dose exerted an effect on endometrial thickness across time. Conclusions Our RCT verified the long-term overall safety of consuming soy isoflavone tablets by postmenopausal women who displayed excellent compliance. We found no evidence of a treatment effect on endometrial thickness, adverse events, or circulating hormone concentrations, most notably thyroid function, during a three year period. PMID:25003624
Distributed electromechanical actuation system design for a morphing trailing edge wing
NASA Astrophysics Data System (ADS)
Dimino, I.; Diodati, G.; Concilio, A.; Volovick, A.; Zivan, L.
2016-04-01
Next-generation flight control actuation technology will be based on "more electric" concepts to ensure benefits in terms of efficiency, weight and maintenance. This paper is concerned with the design of an un-shafted distributed servo-electromechanical actuation system, suited for morphing trailing edge wings of large commercial aircraft. It aims at producing small wing camber variations in the range between -5° and +5° in cruise, to enable aerodynamic efficiency improvements. The deployment kinematics is based on multiple "direct-drive" actuation, each made of light-weight compact lever mechanisms, rigidly connected to compliant ribs and sustained by load-bearing motors. Navier-Stokes computations are performed to estimate the pressure distribution over the interested wing region and the resulting hinge moments. These transfer to the primary structure via the driving mechanism. An electro-mechanical Matlab/Simulink model of the distributed actuation architecture is developed and used as a design tool, to preliminary evaluate the complete system performance. Implementing a multi-shaft strategy, each actuator is sized for the torque acting on the respective adaptive rib, following the effect of both the aerodynamic pressure and the morphing skin stiffness. Elastic trailing edge rotations and power needs are evaluated in operative conditions. Focus is finally given to the key challenges of the proposed concept: targeting quantifiable performance improvements while being compliant to the demanding requirements in terms of reliability and safety.
HIPAA Compliant Wireless Sensing Smartwatch Application for the Self-Management of Pediatric Asthma
Hosseini, Anahita; Buonocore, Chris M.; Hashemzadeh, Sepideh; Hojaiji, Hannaneh; Kalantarian, Haik; Sideris, Costas; Bui, Alex A.T.; King, Christine E.; Sarrafzadeh, Majid
2018-01-01
Asthma is the most prevalent chronic disease among pediatrics, as it is the leading cause of student absenteeism and hospitalization for those under the age of 15. To address the significant need to manage this disease in children, the authors present a mobile health (mHealth) system that determines the risk of an asthma attack through physiological and environmental wireless sensors and representational state transfer application program interfaces (RESTful APIs). The data is sent from wireless sensors to a smartwatch application (app) via a Health Insurance Portability and Accountability Act (HIPAA) compliant cryptography framework, which then sends data to a cloud for real-time analytics. The asthma risk is then sent to the smartwatch and provided to the user via simple graphics for easy interpretation by children. After testing the safety and feasibility of the system in an adult with moderate asthma prior to testing in children, it was found that the analytics model is able to determine the overall asthma risk (high, medium, or low risk) with an accuracy of 80.10±14.13%. Furthermore, the features most important for assessing the risk of an asthma attack were multifaceted, highlighting the importance of continuously monitoring different wireless sensors and RESTful APIs. Future testing this asthma attack risk prediction system in pediatric asthma individuals may lead to an effective self-management asthma program. PMID:29354688
Fambri, Francesco; Dumbser, Michael; Casulli, Vincenzo
2014-11-01
Blood flow in arterial systems can be described by the three-dimensional Navier-Stokes equations within a time-dependent spatial domain that accounts for the elasticity of the arterial walls. In this article, blood is treated as an incompressible Newtonian fluid that flows through compliant vessels of general cross section. A three-dimensional semi-implicit finite difference and finite volume model is derived so that numerical stability is obtained at a low computational cost on a staggered grid. The key idea of the method consists in a splitting of the pressure into a hydrostatic and a non-hydrostatic part, where first a small quasi-one-dimensional nonlinear system is solved for the hydrostatic pressure and only in a second step the fully three-dimensional non-hydrostatic pressure is computed from a three-dimensional nonlinear system as a correction to the hydrostatic one. The resulting algorithm is robust, efficient, locally and globally mass conservative, and applies to hydrostatic and non-hydrostatic flows in one, two and three space dimensions. These features are illustrated on nontrivial test cases for flows in tubes with circular or elliptical cross section where the exact analytical solution is known. Test cases of steady and pulsatile flows in uniformly curved rigid and elastic tubes are presented. Wherever possible, axial velocity development and secondary flows are shown and compared with previously published results. Copyright © 2014 John Wiley & Sons, Ltd.
Compliant high temperature seals for dissimilar materials
Rynders, Steven Walton; Minford, Eric; Tressler, Richard Ernest; Taylor, Dale M.
2001-01-01
A high temperature, gas-tight seal is formed by utilizing one or more compliant metallic toroidal ring sealing elements, where the applied pressure serves to activate the seal, thus improving the quality of the seal. The compliant nature of the sealing element compensates for differences in thermal expansion between the materials to be sealed, and is particularly useful in sealing a metallic member and a ceramic tube art elevated temperatures. The performance of the seal may be improved by coating the sealing element with a soft or flowable coating such as silver or gold and/or by backing the sealing element with a bed of fine powder. The material of the sealing element is chosen such that the element responds to stress elastically, even at elevated temperatures, permitting the seal to operate through multiple thermal cycles.
Synthesis and Evaluation of A High Precision 3D-Printed Ti6Al4V Compliant Parallel Manipulator
NASA Astrophysics Data System (ADS)
Pham, Minh Tuan; Teo, Tat Joo; Huat Yeo, Song; Wang, Pan; Nai, Mui Ling Sharon
2017-12-01
A novel 3D printed compliant parallel manipulator (CPM) with θX - θX - Z motions is presented in this paper. This CPM is synthesized using the beam-based method, a new structural optimization approach, to achieve optimized stiffness properties with targeted dynamic behavior. The CPM performs high non-actuating stiffness based on the predicted stiffness ratios of about 3600 for translations and 570 for rotations, while the dynamic response is fast with the targeted first resonant mode of 100Hz. A prototype of the synthesized CPM is fabricated using the electron beam melting (EBM) technology with Ti6Al4V material. Driven by three voice-coil (VC) motors, the CPM demonstrated a positioning resolution of 50nm along the Z axis and an angular resolution of ~0.3 “about the X and Y axes, the positioning accuracy is also good with the measured values of ±25.2nm and ±0.17” for the translation and rotations respectively. Experimental investigation also shows that this large workspace CPM has a first resonant mode of 98Hz and the stiffness behavior matches the prediction with the highest deviation of 11.2%. Most importantly, the full workspace of 10° × 10° × 7mm of the proposed CPM can be achieved, that demonstrates 3D printed compliant mechanisms can perform large elastic deformation. The obtained results show that CPMs printed by EBM technology have predictable mechanical characteristics and are applicable in precise positioning systems.
Tuberculosis in the workplace: OSHA's compliance experience.
McDiarmid, M; Gamponia, M J; Ryan, M A; Hirshon, J M; Gillen, N A; Cox, M
1996-03-01
Inspections of 272 facilities were performed between May 1992 and October 1994 to determine compliance with applicable Occupational Safety and Health Administration (OSHA) requirements for prevention of tuberculosis (TB) transmission. Retrospective record review of two data sources: (1) OSHA's Computerized Integrated Management Information System and (2) an inspector-completed questionnaire on inspection results. Inspections of five types of facilities: healthcare institutions, correctional facilities, homeless shelters, long-term-care facilities for the elderly, and others, including drug treatment centers that the Centers for Disease Control and Prevention (CDC) identified as having a higher than expected rate of TB. The OSHA Compliance Memorandum, based on the 1990 CDC Guidelines, which outlined elements of a TB prevention program, was used in performing 272 inspections of facilities between May 1992 and October 1994. Elements of compliance were recorded and reviewed from the IMIS database and inspectors' questionnaires. Regulated facilities were not fully compliant with OSHA guidance. Generally, healthcare facilities performed better than other facilities. Most facilities (79%) were compliant with administrative elements of a comprehensive TB control program, such as early identification of known or suspected infectious TB patients and skin testing of workers. Only 29% of inspected facilities were found to have acceptable respiratory protection programs for the prevention of occupational TB. Facilities have not been fully compliant with the OSHA memorandum describing protection of workers from TB. Facility compliance was better with some traditionally recognized TB infection control elements, but was weaker in the area of respiratory protection programs. This may reflect a lack of familiarity with the latter type of hazard protection.