Bērziņš, Agris; Actiņš, Andris
2014-06-01
The dehydration kinetics of mildronate dihydrate [3-(1,1,1-trimethylhydrazin-1-ium-2-yl)propionate dihydrate] was analyzed in isothermal and nonisothermal modes. The particle size, sample preparation and storage, sample weight, nitrogen flow rate, relative humidity, and sample history were varied in order to evaluate the effect of these factors and to more accurately interpret the data obtained from such analysis. It was determined that comparable kinetic parameters can be obtained in both isothermal and nonisothermal mode. However, dehydration activation energy values obtained in nonisothermal mode showed variation with conversion degree because of different rate-limiting step energy at higher temperature. Moreover, carrying out experiments in this mode required consideration of additional experimental complications. Our study of the different sample and experimental factor effect revealed information about changes of the dehydration rate-limiting step energy, variable contribution from different rate limiting steps, as well as clarified the dehydration mechanism. Procedures for convenient and fast determination of dehydration kinetic parameters were offered. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
CFO compensation method using optical feedback path for coherent optical OFDM system
NASA Astrophysics Data System (ADS)
Moon, Sang-Rok; Hwang, In-Ki; Kang, Hun-Sik; Chang, Sun Hyok; Lee, Seung-Woo; Lee, Joon Ki
2017-07-01
We investigate feasibility of carrier frequency offset (CFO) compensation method using optical feedback path for coherent optical orthogonal frequency division multiplexing (CO-OFDM) system. Recently proposed CFO compensation algorithms provide wide CFO estimation range in electrical domain. However, their practical compensation range is limited by sampling rate of an analog-to-digital converter (ADC). This limitation has not drawn attention, since the ADC sampling rate was high enough comparing to the data bandwidth and CFO in the wireless OFDM system. For CO-OFDM, the limitation is becoming visible because of increased data bandwidth, laser instability (i.e. large CFO) and insufficient ADC sampling rate owing to high cost. To solve the problem and extend practical CFO compensation range, we propose a CFO compensation method having optical feedback path. By adding simple wavelength control for local oscillator, the practical CFO compensation range can be extended to the sampling frequency range. The feasibility of the proposed method is experimentally investigated.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.
Sampling studies to estimate the HIV prevalence rate in female commercial sex workers.
Pascom, Ana Roberta Pati; Szwarcwald, Célia Landmann; Barbosa Júnior, Aristides
2010-01-01
We investigated sampling methods being used to estimate the HIV prevalence rate among female commercial sex workers. The studies were classified according to the adequacy or not of the sample size to estimate HIV prevalence rate and according to the sampling method (probabilistic or convenience). We identified 75 studies that estimated the HIV prevalence rate among female sex workers. Most of the studies employed convenience samples. The sample size was not adequate to estimate HIV prevalence rate in 35 studies. The use of convenience sample limits statistical inference for the whole group. It was observed that there was an increase in the number of published studies since 2005, as well as in the number of studies that used probabilistic samples. This represents a large advance in the monitoring of risk behavior practices and HIV prevalence rate in this group.
Wang, Haomin; Wang, Le; Xu, Xiaoji G.
2016-01-01
Scattering-type scanning near-field optical microscopy (s-SNOM) allows spectroscopic imaging with spatial resolution below the diffraction limit. With suitable light sources, s-SNOM is instrumental in numerous discoveries at the nanoscale. So far, the light sources have been limited to continuous wave or high-repetition-rate pulsed lasers. Low-repetition-rate pulsed sources cannot be used, due to the limitation of the lock-in detection mechanism that is required for current s-SNOM techniques. Here, we report a near-field signal extraction method that enables low-repetition-rate pulsed light sources. The method correlates scattering signals from pulses with the mechanical phases of the oscillating s-SNOM probe to obtain near-field signal, by-passing the apparent restriction imposed by the Nyquist–Shannon sampling theorem on the repetition rate. The method shall enable s-SNOM with low-repetition-rate pulses with high-peak-powers, such as femtosecond laser amplifiers, to facilitate investigations of strong light–matter interactions and nonlinear processes at the nanoscale. PMID:27748360
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of
Code of Federal Regulations, 2010 CFR
2010-10-01
... chromatograph. Detection limit: 0.04 ppm. Recommended air volume and sampling rate: 10 liter at 0.2 liter/min. 1... tube must be less than one inch of mercury at a flow rate of one liter per minute. 3.3. Gas... passed through any hose or tubing before entering the charcoal tube. 5.3.5. A sample size of 10 liters is...
Code of Federal Regulations, 2011 CFR
2011-10-01
... chromatograph. Detection limit: 0.04 ppm. Recommended air volume and sampling rate: 10 liter at 0.2 liter/min. 1... tube must be less than one inch of mercury at a flow rate of one liter per minute. 3.3. Gas... passed through any hose or tubing before entering the charcoal tube. 5.3.5. A sample size of 10 liters is...
Selection of sampling rate for digital control of aircrafts
NASA Technical Reports Server (NTRS)
Katz, P.; Powell, J. D.
1974-01-01
The considerations in selecting the sample rates for digital control of aircrafts are identified and evaluated using the optimal discrete method. A high performance aircraft model which includes a bending mode and wind gusts was studied. The following factors which influence the selection of the sampling rates were identified: (1) the time and roughness response to control inputs; (2) the response to external disturbances; and (3) the sensitivity to variations of parameters. It was found that the time response to a control input and the response to external disturbances limit the selection of the sampling rate. The optimal discrete regulator, the steady state Kalman filter, and the mean response to external disturbances are calculated.
Sample-Clock Phase-Control Feedback
NASA Technical Reports Server (NTRS)
Quirk, Kevin J.; Gin, Jonathan W.; Nguyen, Danh H.; Nguyen, Huy
2012-01-01
To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s.
NASA Astrophysics Data System (ADS)
Zhao, Ming; Wang, Xuefeng; Nolte, David
2009-02-01
In solid-support immunoassays, the transport of target analyte in sample solution to capture molecules on the sensor surface controls the detected binding signal. Depletion of the target analyte in the sample solution adjacent to the sensor surface leads to deviations from ideal association, and causes inhomogeneity of surface binding as analyte concentration varies spatially across the sensor surface. In the field of label-free optical biosensing, studies of mass-transport-limited reaction kinetics have focused on the average response on the sensor surface, but have not addressed binding inhomogeneities caused by mass-transport limitations. In this paper, we employ Molecular Interferometric Imaging (MI2) to study mass-transport-induced inhomogeneity of analyte binding within a single protein spot. Rabbit IgG binding to immobilized protein A/G was imaged at various concentrations and under different flow rates. In the mass-transport-limited regime, enhanced binding at the edges of the protein spots was caused by depletion of analyte towards the center of the protein spots. The magnitude of the inhomogeneous response was a function of analyte reaction rate and sample flow rate.
High-speed fixed-target serial virus crystallography
Roedig, Philip; Ginn, Helen M.; Pakendorf, Tim; ...
2017-06-19
Here, we report a method for serial X-ray crystallography at X-ray free-electron lasers (XFELs), which allows for full use of the current 120-Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micropatterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery, we were able to determine the crystal structures of the picornavirus bovine enterovirus 2 (BEV2) and the cytoplasmic polyhedrosis virus type 18 polyhedrin, with total data collection times of less than 14 and 10 min, respectively. Our method requires only micrograms of sample and should therefore broaden the applicability of serial femtosecond crystallographymore » to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for most efficient use of the limited beam time available at XFELs and should enable a substantial increase in sample throughput at these facilities.« less
High-speed fixed-target serial virus crystallography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roedig, Philip; Ginn, Helen M.; Pakendorf, Tim
Here, we report a method for serial X-ray crystallography at X-ray free-electron lasers (XFELs), which allows for full use of the current 120-Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micropatterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery, we were able to determine the crystal structures of the picornavirus bovine enterovirus 2 (BEV2) and the cytoplasmic polyhedrosis virus type 18 polyhedrin, with total data collection times of less than 14 and 10 min, respectively. Our method requires only micrograms of sample and should therefore broaden the applicability of serial femtosecond crystallographymore » to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for most efficient use of the limited beam time available at XFELs and should enable a substantial increase in sample throughput at these facilities.« less
High-speed fixed-target serial virus crystallography
Roedig, Philip; Ginn, Helen M.; Pakendorf, Tim; Sutton, Geoff; Harlos, Karl; Walter, Thomas S.; Meyer, Jan; Fischer, Pontus; Duman, Ramona; Vartiainen, Ismo; Reime, Bernd; Warmer, Martin; Brewster, Aaron S.; Young, Iris D.; Michels-Clark, Tara; Sauter, Nicholas K.; Kotecha, Abhay; Kelly, James; Rowlands, David J.; Sikorsky, Marcin; Nelson, Silke; Damiani, Daniel S.; Alonso-Mori, Roberto; Ren, Jingshan; Fry, Elizabeth E.; David, Christian; Stuart, David I.; Wagner, Armin; Meents, Alke
2017-01-01
We report a method for serial X-ray crystallography at X-ray free electron lasers (XFELs), which allows for full use of the current 120 Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micro-patterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery we were able to determine the crystal structures of a picornavirus, bovine enterovirus 2 (BEV2), and the cytoplasmic polyhedrosis virus type 18 polyhedrin. Total data collection times were less than 14 and 10 minutes, respectively. Our method requires only micrograms of sample and will therefore broaden the applicability of serial femtosecond crystallography to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for the most efficient use of the limited beamtime available at XFELs and should enable a substantial increase in sample throughput at these facilities. PMID:28628129
Rating effectiveness of herbicides in desiccating woody vegetation
Jay R. Bentley; Charles A. Graham
1976-01-01
When the effectiveness of herbicide desiccants for killing and drying woody vegetation on many small test plots is rated, the standard procedures for collecting fuel moisture samples are time consuming and costly. Also, the field data often must be recorded when weather is not suitable for collecting moisture content samples. To overcome these limitations, a new...
Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.
1998-01-01
Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.
Manav, Ramazan; Uğur Görgün, Aysun; Filizok, Işık
2016-11-09
The pollution level of Lake Bafa was investigated by collecting fish samples { Dicentrarchus labrax (sea bass), Liza ramada (mullet) and Anguilla anguilla (eel)}, surface sediment, and core samples. In all these samples, 210 Po and 210 Pb concentrations were estimated, and total annual dose rates were obtained for each species. Some heavy metal (Cr, Ni, Pb, Cd, Mn, Fe, and Zn) concentration levels were obtained for the fish and a core sample. The sediment mass accumulation rate was found to be 3.27 g·m -2 ·day -1 (0.119 g·cm -2 ·y -1 ) from a core sample. The heavy metal concentrations in the vertical profile of samples from the core were also observed. The measured concentration of Zn, Pb, Cd, and Cr were between the ERL (effects range low) and ERM (effects range median) limits, while Ni concentrations were higher than the ERM limit. The observed concentrations of Cd, Pb, and Zn in fish samples did not exceed the limits in accordance with Turkish Food Regulations. Further, the maximum effective dose equivalent of 210 Po in the area was found to be 1.169 µSv·y -1 .
Pushing x-ray photon correlation spectroscopy beyond the continuous frame rate limit
Dufresne, Eric M.; Narayanan, Suresh; Sandy, Alec R.; ...
2016-01-06
We demonstrate delayed-frame X-ray Photon Correlation Spectroscopy with 120 microsecond time resolution, limited only by sample scattering rates, with a prototype Pixel-array detector capable of taking two image frames separated by 153 ns or less. Although the overall frame rate is currently limited to about 4 frame pairs per second, we easily measured millisecond correlation functions. In conclusion, this technology, coupled to the use of brighter synchrotrons such as Petra III or the NSLS-II should enable X-ray Photon Correlation Spectroscopy on microsecond time scales on a wider variety of materials.
Yu, Tina; Qu, Shoufang; Zhang, Xiaoyan; Sun, Nan; Gao, Shangxian; Li, Haining; Huang, Jie
2015-07-01
To evaluate the quality status of rubella virus IgM diagnostic kits by national supervising sampling. Using legal inspection combining with exploratory study, the positive and negative coincidence rate, detection limit and repeatability of kits were verified. The results showed that 15 of 16 batches of kits were qualified using legal inspection, and the passing rate was 93.8%. The unqualified item was negative coincidence rate. In exploratory study, only 11 batches (68.8%) complied with industry standard. The unqualified items were negative coincidence rate, detection limit and repeatability. At present, rubella virus IgM diagnostic Kits have some quality problems in the market. It is recommended that we adopt industry standard and national reference panel in the registration inspection for the future, which will prompt enterprises to improve quality.
Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marginean, Ioan; Tang, Keqi; Smith, Richard D.
2014-01-01
Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, themore » ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.« less
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride.
Influence of sampling rate on the calculated fidelity of an aircraft simulation
NASA Technical Reports Server (NTRS)
Howard, J. C.
1983-01-01
One of the factors that influences the fidelity of an aircraft digital simulation is the sampling rate. As the sampling rate is increased, the calculated response of the discrete representation tends to coincide with the response of the corresponding continuous system. Because of computer limitations, however, the sampling rate cannot be increased indefinitely. Moreover, real-time simulation requirements demand that a finite sampling rate be adopted. In view of these restrictions, a study was undertaken to determine the influence of sampling rate on the response characteristics of a simulated aircraft describing short-period oscillations. Changes in the calculated response characteristics of the simulated aircraft degrade the fidelity of the simulation. In the present context, fidelity degradation is defined as the percentage change in those characteristics that have the greatest influence on pilot opinion: short period frequency omega, short period damping ratio zeta, and the product omega zeta. To determine the influence of the sampling period on these characteristics, the equations describing the response of a DC-8 aircraft to elevator control inputs were used. The results indicate that if the sampling period is too large, the fidelity of the simulation can be degraded.
Optimal Inspection of Imports to Prevent Invasive Pest Introduction.
Chen, Cuicui; Epanchin-Niell, Rebecca S; Haight, Robert G
2018-03-01
The United States imports more than 1 billion live plants annually-an important and growing pathway for introduction of damaging nonnative invertebrates and pathogens. Inspection of imports is one safeguard for reducing pest introductions, but capacity constraints limit inspection effort. We develop an optimal sampling strategy to minimize the costs of pest introductions from trade by posing inspection as an acceptance sampling problem that incorporates key features of the decision context, including (i) simultaneous inspection of many heterogeneous lots, (ii) a lot-specific sampling effort, (iii) a budget constraint that limits total inspection effort, (iv) inspection error, and (v) an objective of minimizing cost from accepted defective units. We derive a formula for expected number of accepted infested units (expected slippage) given lot size, sample size, infestation rate, and detection rate, and we formulate and analyze the inspector's optimization problem of allocating a sampling budget among incoming lots to minimize the cost of slippage. We conduct an empirical analysis of live plant inspection, including estimation of plant infestation rates from historical data, and find that inspections optimally target the largest lots with the highest plant infestation rates, leaving some lots unsampled. We also consider that USDA-APHIS, which administers inspections, may want to continue inspecting all lots at a baseline level; we find that allocating any additional capacity, beyond a comprehensive baseline inspection, to the largest lots with the highest infestation rates allows inspectors to meet the dual goals of minimizing the costs of slippage and maintaining baseline sampling without substantial compromise. © 2017 Society for Risk Analysis.
Near-Limit Flamelet Phenomena in Buoyant Low Stretch Diffusion Flames Beneath a Solid Fuel
NASA Technical Reports Server (NTRS)
Olson, S. L.; Tien, J. S.
2000-01-01
A unique near-limit low stretch multidimensional stable flamelet phenomena has been observed for the first time which extends the material flammability limit beyond the one-dimensional low stretch flammability limit to lower burning rates and higher relative heat losses than is possible with uniform flame coverage. During low stretch experiments burning the underside of very large radii (greater than or = 75 cm stretch rate less than or = 3/s) cylindrical cast PMMA samples, multidimensional flamelets were observed, in contrast with a one-dimensional flame that was found to blanket the surface for smaller radii samples ( higher stretch rate). Flamelets were observed by decreasing the stretch rate or by increasing the conductive heat loss from the flame. Flamelets are defined as flames that cover only part of the burning sample at any given time, but persist for many minutes. Flamelet phenomena is viewed as the flame's method of enhancing oxygen flow to the flame, through oxygen transport into the edges of the flamelet. Flamelets form as heat losses (surface radiation and solid-phase conduction) become large relative to the weakened heat release of the low stretch flame. While heat loss rates remain fairly constant, the limiting factor in the heat release of the flame is hypothesized to be the oxygen transport to the flame in this low stretch (low convective) environment. Flamelet extinction is frequently caused by encroachment of an adjacent flamelet. Large-scale whole-body flamelet oscillations at 1.2 - 1.95 Hz are noted prior to extinction of a flamelet. This oscillation is believed to be due a repeated process of excess fuel leakage through the dark channels between the flamelets, fuel premixing with slow incoming oxidizer, and subsequent rapid flame spread and retreat of the flamelet through the premixed layer. The oscillation frequency is driven by gas-phase diffusive time scales.
Occurrence of aflatoxin M(1) in raw and market milk commercialized in Greece.
Roussi, V; Govaris, A; Varagouli, A; Botsoglou, N A
2002-09-01
From December 1999 to May 2000, 114 samples of pasteurized, ultrahigh temperature-treated (UHT) and concentrated milk were collected in supermarkets, whereas 52 raw milk samples from cow, sheep and goat were obtained from different milk producers all over Greece. Sample collection was repeated from December 2000 to May 2001 and concerned 54 samples of pasteurized milk, 23 samples of bulk-tank raw milk and 55 raw milk samples from cow, sheep and goat. The total number of samples analysed for aflatoxin M(1) (AFM(1)) contamination by immunoaffinity column extraction and liquid chromatography was 297. In the first sampling, the incidence rates of AFM(1) contamination in pasteurized, UHT, concentrated and cow, sheep and goat raw milk were 85.4, 82.3, 93.3, 73.3, 66.7 and 40%, respectively, with only one cow raw milk and two concentrated milk samples exceeding the EU limit of 50 ng l(-1). In the second sampling, the incidence rates of AFM(1) contamination in pasteurized, bulk-tank and cow, sheep and goat raw milk were 79.6, 78.3, 64.3, 73.3 and 66.7%, respectively, with only one cow and one sheep raw milk samples exceeding the limit of 50 ng l(-1). The results suggest that the current regulatory status in Greece is effective.
Diaz, G J; Ariza, D; Perilla, N S
2004-06-01
A method was validated for the determination of ochratoxin A (OTA) in soluble and green coffee. Performance parameters evaluated included selectivity, accuracy, intermediate precision, linearity, limit of detection, limit of quantitation, and ruggedness. The method was found to be selective for OTA in both matrices tested. Recovery rates from soluble coffee samples ranged from 73.5 to 91.2%, and from green coffee samples from 68.7 to 84.5%. The intermediate precision (RSDr) was between 9.1 and 9.4% for soluble coffee and between 14.3 and 15.5% for green coffee analysis. The linearity of the standard calibration curve (r(2)) was <0.999 for OTA levels of 1.0-20.0 μg/kg in coffee samples. The limit of detection was determined to be 0.01 ng of OTA on column, while the limit of quantitation was found to be 0.03 ng on column. The limit of quantitation is equivalent to 0.6 μg/kg in soluble coffee samples and 0.3 μg/kg in green coffee samples. The results of the ruggedness trial showed two factors are critical for soluble coffee analysis: the extraction method, and the flow rate of the mobile phase. For green coffee analysis two critical factors detected were the extraction method and the storage temperature of the immunoaffinity column.Five samples of soluble coffee and 42 of green coffee were analysed using the validated method. All soluble coffee samples contained OTA at levels that ranged from 8.4 to 13.9 μg/kg. Six of the 42 green coffee samples analysed (14.3%) contained OTA at levels ranging from 0.9 to 19.4 μg/kg. The validated method can be used to monitor OTA levels in Colombian coffee for export or for local consumption.
Bennett, James S; Marlow, David A; Nourian, Fariba; Breay, James; Hammond, Duane
2016-01-01
Exposure control systems performance was investigated in an aircraft painting hangar. The ability of the ventilation system and respiratory protection program to limit worker exposures was examined through air sampling during painting of F/A-18C/D strike fighter aircraft, in four field surveys. Air velocities were measured across the supply filter, exhaust filter, and hangar midplane under crossflow ventilation. Air sampling conducted during painting process phases (wipe-down, primer spraying, and topcoat spraying) encompassed volatile organic compounds, total particulate matter, Cr[VI], metals, nitroethane, and hexamethylene diisocyanate, for two worker groups: sprayers and sprayer helpers ("hosemen"). One of six methyl ethyl ketone and two of six methyl isobutyl ketone samples exceeded the short term exposure limits of 300 and 75 ppm, with means 57 ppm and 63 ppm, respectively. All 12 Cr[VI] 8-hr time-weighted averages exceeded the recommended exposure limit of 1 µg/m3, 11 out of 12 exceeded the permissible exposure limit of 5 µg/m3, and 7 out of 12 exceeded the threshold limit value of 10 µg/m3, with means 38 µg/m3 for sprayers and 8.3 µg/m3 for hosemen. Hexamethylene diisocyanate means were 5.95 µg/m3 for sprayers and 0.645 µg/m3 for hosemen. Total reactive isocyanate group--the total of monomer and oligomer as NCO group mass--showed 6 of 15 personal samples exceeded the United Kingdom Health and Safety Executive workplace exposure limit of 20 µg/m3, with means 50.9 µg/m3 for sprayers and 7.29 µg/m3 for hosemen. Several exposure limits were exceeded, reinforcing continued use of personal protective equipment. The supply rate, 94.4 m3/s (200,000 cfm), produced a velocity of 8.58 m/s (157 fpm) at the supply filter, while the exhaust rate, 68.7 m3/s (146,000 cfm), drew 1.34 m/s (264 fpm) at the exhaust filter. Midway between supply and exhaust locations, the velocity was 0.528 m/s (104 fpm). Supply rate exceeding exhaust rate created re-circulations, turbulence, and fugitive emissions, while wasting energy. Smoke releases showing more effective ventilation here than in other aircraft painting facilities carries technical feasibility relevance.
Bennett, James S.; Marlow, David A.; Nourian, Fariba; Breay, James; Hammond, Duane
2016-01-01
Exposure control systems performance was investigated in an aircraft painting hangar. The ability of the ventilation system and respiratory protection program to limit worker exposures was examined through air sampling during painting of F/A-18C/D strike fighter aircraft, in four field surveys. Air velocities were measured across the supply filter, exhaust filter, and hangar midplane under crossflow ventilation. Air sampling conducted during painting process phases (wipe-down, primer spraying, and topcoat spraying) encompassed volatile organic compounds, total particulate matter, Cr[VI], metals, nitroethane, and hexamethylene diisocyanate, for two worker groups: sprayers and sprayer helpers (“hosemen”). One of six methyl ethyl ketone and two of six methyl isobutyl ketone samples exceeded the short term exposure limits of 300 and 75 ppm, with means 57 ppm and 63 ppm, respectively. All 12 Cr[VI] 8-hr time-weighted averages exceeded the recommended exposure limit of 1 µg/m3, 11 out of 12 exceeded the permissible exposure limit of 5 µg/m3, and 7 out of 12 exceeded the threshold limit value of 10 µg/m3, with means 38 µg/m3 for sprayers and 8.3 µg/m3 for hosemen. Hexamethylene diisocyanate means were 5.95 µg/m3 for sprayers and 0.645 µg/m3 for hosemen. Total reactive isocyanate group—the total of monomer and oligomer as NCO group mass—showed six of 15 personal samples exceeded the United Kingdom Health and Safety Executive workplace exposure limit of 20 µg/m3, with means 50.9 µg/m3 for sprayers and 7.29 µg/m3 for hosemen. Several exposure limits were exceeded, reinforcing continued use of personal protective equipment. The supply rate, 94.4 m3/s (200,000 cfm), produced a velocity of 8.58 m/s (157 fpm) at the supply filter, while the exhaust rate, 68.7 m3/s (146,000 cfm), drew 1.34 m/s (264 fpm) at the exhaust filter. Midway between supply and exhaust locations, the velocity was 0.528 m/s (104 fpm). Supply rate exceeding exhaust rate created re-circulations, turbulence, and fugitive emissions, while wasting energy. Smoke releases showing more effective ventilation here than in other aircraft painting facilities carries technical feasibility relevance. PMID:26698920
Sub-Nyquist Sampling and Moire-Like Waveform Distortions
NASA Technical Reports Server (NTRS)
Williams, Glenn L.
2000-01-01
Investigations of aliasing effects in digital waveform sampling have revealed the existence of a mathematical field and a pseudo-alias domain lying to the left of a "Nyquist line" in a plane defining the boundary between two domains of sampling. To the right of the line lies the classic alias domain. For signals band-limited below the Nyquist limit, displayed output may show a false modulation envelope. The effect occurs whenever the sample rate and the signal frequency are related by ratios of mutually prime integers. Belying the principal of a 10:1 sampling ratio being "good enough", this distortion easily occurs in graphed one-dimensional waveforms and two-dimensional images and occurs daily on television.
Rate Constant and Reaction Coordinate of Trp-Cage Folding in Explicit Water
Juraszek, Jarek; Bolhuis, Peter G.
2008-01-01
We report rate constant calculations and a reaction coordinate analysis of the rate-limiting folding and unfolding process of the Trp-cage mini-protein in explicit solvent using transition interface sampling. Previous transition path sampling simulations revealed that in this (un)folding process the protein maintains its compact configuration, while a (de)increase of secondary structure is observed. The calculated folding rate agrees reasonably with experiment, while the unfolding rate is 10 times higher. We discuss possible origins for this mismatch. We recomputed the rates with the forward flux sampling method, and found a discrepancy of four orders of magnitude, probably caused by the method's higher sensitivity to the choice of order parameter with respect to transition interface sampling. Finally, we used the previously computed transition path-sampling ensemble to screen combinations of many order parameters for the best model of the reaction coordinate by employing likelihood maximization. We found that a combination of the root mean-square deviation of the helix and of the entire protein was, of the set of tried order parameters, the one that best describes the reaction coordination. PMID:18676648
A low-volume cavity ring-down spectrometer for sample-limited applications
NASA Astrophysics Data System (ADS)
Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.
2014-08-01
In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.
ERIC Educational Resources Information Center
Haydarov, Rustam; Moxley, Virginia; Anderson, Dawn
2013-01-01
This article examines definitions, rationales, and calculations associated with higher education performance measures: persistence, retention rate, attrition rate, drop-out rate, and graduation rate. Strengths and limitations of these measures are scrutinized relative to online master's programs. Outcomes of a sample of students (N = 96) enrolled…
A neural algorithm for the non-uniform and adaptive sampling of biomedical data.
Mesin, Luca
2016-04-01
Body sensors are finding increasing applications in the self-monitoring for health-care and in the remote surveillance of sensitive people. The physiological data to be sampled can be non-stationary, with bursts of high amplitude and frequency content providing most information. Such data could be sampled efficiently with a non-uniform schedule that increases the sampling rate only during activity bursts. A real time and adaptive algorithm is proposed to select the sampling rate, in order to reduce the number of measured samples, but still recording the main information. The algorithm is based on a neural network which predicts the subsequent samples and their uncertainties, requiring a measurement only when the risk of the prediction is larger than a selectable threshold. Four examples of application to biomedical data are discussed: electromyogram, electrocardiogram, electroencephalogram, and body acceleration. Sampling rates are reduced under the Nyquist limit, still preserving an accurate representation of the data and of their power spectral densities (PSD). For example, sampling at 60% of the Nyquist frequency, the percentage average rectified errors in estimating the signals are on the order of 10% and the PSD is fairly represented, until the highest frequencies. The method outperforms both uniform sampling and compressive sensing applied to the same data. The discussed method allows to go beyond Nyquist limit, still preserving the information content of non-stationary biomedical signals. It could find applications in body sensor networks to lower the number of wireless communications (saving sensor power) and to reduce the occupation of memory. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tang, Liang; Kwon, Hyun J; Kang, Kyung A
2004-12-30
Protein C (PC) is an important anticoagulant in human blood plasma, and early diagnosis of PC deficiency is critical for preventing dangerous thromboembolic complications. A fiber-optic PC immuno-biosensor has been under development in our research group for real-time PC-deficiency diagnosis. The sensor has demonstrated a good sensitivity and specificity for quantifying PC in buffered solutions. However, for plasma samples, with a limited sample reaction time, the sensor produced only 30% of the signal intensity of PC in buffer. The high plasma viscosity (1.9 cP) was speculated as the major reason for signal intensity reduction. In this investigation, the sensing performance of the fiber-optic PC biosensor is systematically characterized in terms of physical and chemical properties of the sample media. Theoretical and experimental analyses indicate that the reduced diffusion rate of PC molecules in viscous samples caused the sensing system to be more mass-transfer-limited. Convective flow of sample/reagent solutions during immunoreactions can increase the rate of the analyte mass transport from the bulk solution to the sensor surface, with reaction kinetics changing from mass-transfer-limited to reaction-limited as flow velocity increases. It was shown that PC sensor performance was significantly improved for plasma samples with convection. The effect of the flow velocity and incubation times for samples and reagents on the sensor performance was also systematically analyzed to optimize the assay protocol for PC sensing. Currently, a 6-cm-long immuno-biosensor is capable of quantifying PC in plasma (1 mL) in the heterozygous PC deficiency range (0.5 to 2.5 microg/mL) within 5 minutes, at an average signal-to-noise ratio of 50. 2004 Wiley Periodicals, Inc.
Toliver-Sokol, Marisol; Murray, Caitlin B; Wilson, Anna C; Lewandowski, Amy; Palermo, Tonya M
2011-07-01
There is limited research describing the patterns of healthcare utilization in adolescents with chronic pain. This study describes healthcare utilization in a clinical chronic pain sample, and compares the patterns of service use of this group to a community sample with intermittent pain complaints. We also investigated demographic and clinical factors that predicted healthcare visits and medication use in the clinical sample. Data on 117 adolescents (aged 12-18; n = 59 clinical pain sample, n = 58 community) were collected. Caregivers and adolescents reported on sociodemographics, medical visits, current medications, pain, activity limitations, and depression. As hypothesized, the clinical pain sample had higher rates of healthcare consultation on all types of medical visits (general, specialty care, complementary medicine, mental health, OT/PT), and higher medication use compared to the community sample. Regression analyses revealed that higher annual income, greater pain frequency, and higher levels of caregiver-reported activity limitations were associated with a greater number of healthcare visits for the total sample. Within the clinical pain sample, higher pain frequency and greater activity limitations (caregiver report) predicted more specialty care visits. Additionally, higher income and greater levels of depressive symptoms predicted a higher number of prescribed medications. This study contributes to the limited available data on health service and medication use in a clinical chronic pain sample versus a community sample of adolescents. We also identify clinical factors (pain frequency, parent-reported activity limitations, depressive symptoms) and demographic factors (gender, income) associated with healthcare utilization. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Graur, Or; Bianco, Federica B.; Modjaz, Maryam; Shivvers, Isaac; Filippenko, Alexei V.; Li, Weidong; Smith, Nathan
2017-03-01
In Paper I of this series, we showed that the ratio between stripped-envelope (SE) supernova (SN) and Type II SN rates reveals a significant SE SN deficiency in galaxies with stellar masses ≲ {10}10 {M}⊙ . Here, we test this result by splitting the volume-limited subsample of the Lick Observatory Supernova Search (LOSS) SN sample into low- and high-mass galaxies and comparing the relative rates of various SN types found in them. The LOSS volume-limited sample contains 180 SNe and SN impostors and is complete for SNe Ia out to 80 Mpc and core-collapse SNe out to 60 Mpc. All of these transients were recently reclassified by us in Shivvers et al. We find that the relative rates of some types of SNe differ between low- and high-mass galaxies: SNe Ib and Ic are underrepresented by a factor of ˜3 in low-mass galaxies. These galaxies also contain the only examples of SN 1987A-like SNe in the sample and host about nine times as many SN impostors. Normal SNe Ia seem to be ˜30% more common in low-mass galaxies, making these galaxies better sources for homogeneous SN Ia cosmology samples. The relative rates of SNe IIb are consistent in both low- and high-mass galaxies. The same is true for broad-line SNe Ic, although our sample includes only two such objects. The results presented here are in tension with a similar analysis from the Palomar Transient Factory, especially as regards SNe IIb.
DRY MERGER RATE AND POST-MERGER FRACTION IN THE COMA CLUSTER CORE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cordero, Juan P.; Campusano, Luis E.; Haines, Christopher P.
2016-01-20
We evaluate the dry merger activity in the Coma cluster, using a spectroscopically complete sample of 70 red-sequence (RS) galaxies, most of which (∼75%) are located within 0.2R{sub 200} (∼0.5 Mpc) from the cluster center, with data from the Coma Treasury Survey obtained with the Hubble Space Telescope. The fraction of close galaxy pairs in the sample is the proxy employed for the estimation of the merger activity. We identify 5 pairs and 1 triplet, enclosing a total of 13 galaxies, based on limits on projected separation and line-of-sight velocity difference. Of these systems, none show signs of ongoing interaction,more » and therefore we do not find any true mergers in our sample. This negative result sets a 1σ upper limit of 1.5% per Gyr for the major dry merger rate, consistent with the low rates expected in present-day clusters. Detailed examination of the images of all the RS galaxies in the sample reveals only one with low surface brightness features identifiable as the remnant of a past merger or interaction, implying a post-merger fraction below 2%.« less
40 CFR 63.1385 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... applicable emission limits: (1) Method 1 (40 CFR part 60, appendix A) for the selection of the sampling port location and number of sampling ports; (2) Method 2 (40 CFR part 60, appendix A) for volumetric flow rate.... Each run shall consist of a minimum run time of 2 hours and a minimum sample volume of 60 dry standard...
Estimating implied rates of discount in healthcare decision-making.
West, R R; McNabb, R; Thompson, A G H; Sheldon, T A; Grimley Evans, J
2003-01-01
To consider whether implied rates of discounting from the perspectives of individual and society differ, and whether implied rates of discounting in health differ from those implied in choices involving finance or "goods". The study comprised first a review of economics, health economics and social science literature and then an empirical estimate of implied rates of discounting in four fields: personal financial, personal health, public financial and public health, in representative samples of the public and of healthcare professionals. Samples were drawn in the former county and health authority district of South Glamorgan, Wales. The public sample was a representative random sample of men and women, aged over 18 years and drawn from electoral registers. The health professional sample was drawn at random with the cooperation of professional leads to include doctors, nurses, professions allied to medicine, public health, planners and administrators. The literature review revealed few empirical studies in representative samples of the population, few direct comparisons of public with private decision-making and few direct comparisons of health with financial discounting. Implied rates of discounting varied widely and studies suggested that discount rates are higher the smaller the value of the outcome and the shorter the period considered. The relationship between implied discount rates and personal attributes was mixed, possibly reflecting the limited nature of the samples. Although there were few direct comparisons, some studies found that individuals apply different rates of discount to social compared with private comparisons and health compared with financial. The present study also found a wide range of implied discount rates, with little systematic effect of age, gender, educational level or long-term illness. There was evidence, in both samples, that people chose a lower rate of discount in comparisons made on behalf of society than in comparisons made for themselves. Both public and health professional samples tended to choose lower discount rates in health-related comparisons than in finance-related comparisons. It was also suggested that implied rates of discount, derived from responses to hypothetical questions, can be influenced by detail of question framing. The study suggested that both the lay public and healthcare professionals consider that the discount rate appropriate for public decisions is lower than that for private decisions. This finding suggests that lay people as well as healthcare professionals, used to making decisions on behalf of others, recognise that society is not simply an aggregate of individuals. It also implies a general appreciation that society is more stable and has a more predictable future than does the individual. There is fairly general support for this view in the theoretical literature and limited support in the few previous direct comparisons. Further research is indicated, possibly involving more in-depth interviewing and drawing inference on real, rather than hypothetical choices.
Inferring Strength of Tantalum from Hydrodynamic Instability Recovery Experiments
NASA Astrophysics Data System (ADS)
Sternberger, Z.; Maddox, B.; Opachich, Y.; Wehrenberg, C.; Kraus, R.; Remington, B.; Randall, G.; Farrell, M.; Ravichandran, G.
2018-05-01
Hydrodynamic instability experiments allow access to material properties at extreme conditions, where strain rates exceed 105 s-1 and pressures reach 100 GPa. Current hydrodynamic instability experimental methods require in-flight radiography to image the instability growth at high pressure and high strain rate, limiting the facilities where these experiments can be performed. An alternate approach, recovering the sample after loading, allows measurement of the instability growth with profilometry. Tantalum samples were manufactured with different 2D and 3D initial perturbation patterns and dynamically compressed by a blast wave generated by laser ablation. The samples were recovered from peak pressures between 30 and 120 GPa and strain rates on the order of 107 s-1, providing a record of the growth of the perturbations due to hydrodynamic instability. These records are useful validation points for hydrocode simulations using models of material strength at high strain rate. Recovered tantalum samples were analyzed, providing an estimate of the strength of the material at high pressure and strain rate.
Bavarnegin, E; Fathabadi, N; Vahabi Moghaddam, M; Vasheghani Farahani, M; Moradi, M; Babakhni, A
2013-03-01
Radon exhalation rates from building materials used in high background radiation areas (HBRA) of Ramsar were measured using an active radon gas analyzer with an emanation container. Radon exhalation rates from these samples varied from below the lower detection limit up to 384 Bq.m(-2) h(-1). The (226)Ra, (232)Th and (40)K contents were also measured using a high resolution HPGe gamma- ray spectrometer system. The activity concentration of (226)Ra, (232)Th and (40)K content varied from below the minimum detection limit up to 86,400 Bq kg(-1), 187 Bq kg(-1) and 1350 Bq kg(-1), respectively. The linear correlation coefficient between radon exhalation rate and radium concentration was 0.90. The result of this survey shows that radon exhalation rate and radium content in some local stones used as basements are extremely high and these samples are main sources of indoor radon emanation as well as external gamma radiation from uranium series. Copyright © 2012 Elsevier Ltd. All rights reserved.
Graf, Alexandra C; Bauer, Peter
2011-06-30
We calculate the maximum type 1 error rate of the pre-planned conventional fixed sample size test for comparing the means of independent normal distributions (with common known variance) which can be yielded when sample size and allocation rate to the treatment arms can be modified in an interim analysis. Thereby it is assumed that the experimenter fully exploits knowledge of the unblinded interim estimates of the treatment effects in order to maximize the conditional type 1 error rate. The 'worst-case' strategies require knowledge of the unknown common treatment effect under the null hypothesis. Although this is a rather hypothetical scenario it may be approached in practice when using a standard control treatment for which precise estimates are available from historical data. The maximum inflation of the type 1 error rate is substantially larger than derived by Proschan and Hunsberger (Biometrics 1995; 51:1315-1324) for design modifications applying balanced samples before and after the interim analysis. Corresponding upper limits for the maximum type 1 error rate are calculated for a number of situations arising from practical considerations (e.g. restricting the maximum sample size, not allowing sample size to decrease, allowing only increase in the sample size in the experimental treatment). The application is discussed for a motivating example. Copyright © 2011 John Wiley & Sons, Ltd.
Mott, Keith A.; Jensen, Richard G.; O'Leary, James W.; Berry, Joseph A.
1984-01-01
The interacting effects of the rate of ribulose 1,5-bisphosphate (RuBP) regeneration and the rate of RuBP utilization as influenced by the amount and activation of RuBP carboxylase on photosynthesis and RuBP concentrations were resolved in experiments which examined the kinetics of the response of photosynthesis and RuBP concentrations after step changes from a rate-saturating to a rate-limiting light intensity in Xanthium strumarium. Because RuBP carboxylase requires several minutes to deactivate in vivo, it was possible to observe the effect of reducing the rate of RuBP regeneration on the RuBP concentration at constant enzyme activation state by sampling very soon after reducing the light intensity. Samples taken over longer time periods showed the effect of changes in enzyme activation at constant RuBP regeneration rate on RuBP concentration and photosynthetic rate. Within 15 s of lowering the light intensity from 1500 to 600 microEinsteins per square meter per second the RuBP concentration in the leaves dropped below the enzyme active site concentration, indicating that RuBP regeneration rate was limiting for photosynthesis. After longer intervals of time, the RuBP concentration in the leaf increased as the RuBP carboxylase assumed a new steady state activation level. No change in the rate of photosynthesis was observed during the interval that RuBP concentration increased. It is concluded that the rate of photosynthesis at the lower light intensity was limited by the rate of RuBP regeneration and that parallel changes in the activation of RuBP carboxylase occurred such that concentrations of RuBP at steady state were not altered by changes in light intensity. PMID:16663982
Mott, K A; Jensen, R G; O'leary, J W; Berry, J A
1984-12-01
The interacting effects of the rate of ribulose 1,5-bisphosphate (RuBP) regeneration and the rate of RuBP utilization as influenced by the amount and activation of RuBP carboxylase on photosynthesis and RuBP concentrations were resolved in experiments which examined the kinetics of the response of photosynthesis and RuBP concentrations after step changes from a rate-saturating to a rate-limiting light intensity in Xanthium strumarium. Because RuBP carboxylase requires several minutes to deactivate in vivo, it was possible to observe the effect of reducing the rate of RuBP regeneration on the RuBP concentration at constant enzyme activation state by sampling very soon after reducing the light intensity. Samples taken over longer time periods showed the effect of changes in enzyme activation at constant RuBP regeneration rate on RuBP concentration and photosynthetic rate. Within 15 s of lowering the light intensity from 1500 to 600 microEinsteins per square meter per second the RuBP concentration in the leaves dropped below the enzyme active site concentration, indicating that RuBP regeneration rate was limiting for photosynthesis. After longer intervals of time, the RuBP concentration in the leaf increased as the RuBP carboxylase assumed a new steady state activation level. No change in the rate of photosynthesis was observed during the interval that RuBP concentration increased. It is concluded that the rate of photosynthesis at the lower light intensity was limited by the rate of RuBP regeneration and that parallel changes in the activation of RuBP carboxylase occurred such that concentrations of RuBP at steady state were not altered by changes in light intensity.
Schmidt, Robert L; Howard, Kirsten; Hall, Brian J; Layfield, Lester J
2012-12-01
Sample adequacy is an important aspect of overall fine-needle aspiration cytology (FNAC) performance. FNAC effectiveness is augmented by an increasing number of needle passes, but increased needle passes are associated with higher costs and greater risk of adverse events. The objective of this study was to compare the impact of several different sampling policies on FNAC effectiveness and adverse event rates using discrete event simulation. We compared 8 different sampling policies in 12 different sampling environments. All sampling policies were effective when the per-pass accuracy is high (>80%). Rapid on-site evaluation (ROSE) improves FNAC effectiveness when the per-pass adequacy rate is low. ROSE is unlikely to be cost-effective in sampling environments in which the per-pass adequacy is high. Alternative ROSE assessors (eg, cytotechnologists) may be a cost-effective alternative to pathologists when the per-pass adequacy rate is moderate (60%-80%) or when the number of needle passes is limited.
Bioaccumulation Study at Puffer Pond
1994-10-01
organism if the rate of intake of the pollutant is greater than the rate of excretion and/or metabolism . The result is an increase in body burden...PARAMETERS FOR FISH TISSUE SAMPLES Method Analyte Estimated Method Detection Limit (pg/g) ORGANOPHOSPHORUS PESTICIDES ATRAZINE 2.5 VAPONA 4.5 MALATHION
Strength and Deformation Behaviour of Cap Rocks Above the CO2SINK-Reservoir
NASA Astrophysics Data System (ADS)
Mutschler, T.; Triantafyllidis, T.; Balthasar, K.; Norden, B.
2009-04-01
The cap-rock of the CO2SINK storage site close to Ketzin consists of clay rich rocks which are typical for cap rock formations above CO2 storage reservoirs. The strength and deformation behaviour of such claystone samples are therefore of fundamental importance for the characterization of secure geological storage of CO2. The elastic and anelastic deformation behaviour limits the maximum injection pressure during CO2-injection and is part of the security measures for the long term storage of CO2. The laboratory experiments where performed on samples gathered from the injection well of the Ketzin pilot test site in Germany and are compared with the elastic and anelastic behaviour of samples from the same Keuper formation in a near-surface outcrop in the Southwest of Germany showing a similar lithology. The samples from the outcrop allowed drilling of samples with a standard size of 100 mm diameter and 200 mm height as well as large samples with a diameter of 550 mm and a height of 1200 mm. The investigations have a special emphasis on the viscous behaviour of the clay stones and its scaling behaviour. A special triaxial testing procedure is applied both on standard and large size samples allowing the determination of the strength, stiffness and viscosity behaviour of the rock in one experimental run. Multi-stage technique (stepwise variation of the confining pressure) gives the strength behaviour of each single sample while applying a constant deformation rate. Stepwise varied deformation rates on the other hand lead to steps in the stress-strain-curve from which the viscosity index is determined. The viscosity index is directly used in the Norton's constitutive relations for viscoplastic simulations. The combination of tests allows for the determination of a broad range of elastic and anelastic properties. The comparison of results - both for elastic and anelastic behaviour - from standard and large samples shows that for the examined rocks a scale effect is negligible. Transition from cataclastic to non-cataclastic behaviour - the transition limit - occurs in a similar range of applied levels of pressure and deformation rates even at room temperature. The obtained transition limit is very important for the judgment of the sealing capacity and integrity of the cap rock. The deformation rates predicted for the pressure and temperature conditions of the caprock at Ketzin test site are far beneath the determined transition limit during the injection and after stop of injection. As a 0° friction angle is used for pressure and deformation limit at Ketzin, the measured elastic and anelastic behaviour of the real caprock act as additional safety margin during injection and in the post injection phase. As the examined rocks are typical for many possible storage sites, the discussed results are of importance beyond the Ketzin Pilot Experiment CO2SINK.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orton, Daniel J.; Tfaily, Malak M.; Moore, Ronald J.
To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, lowmore » pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.« less
Clewe, Oskar; Karlsson, Mats O; Simonsson, Ulrika S H
2015-12-01
Bronchoalveolar lavage (BAL) is a pulmonary sampling technique for characterization of drug concentrations in epithelial lining fluid and alveolar cells. Two hypothetical drugs with different pulmonary distribution rates (fast and slow) were considered. An optimized BAL sampling design was generated assuming no previous information regarding the pulmonary distribution (rate and extent) and with a maximum of two samples per subject. Simulations were performed to evaluate the impact of the number of samples per subject (1 or 2) and the sample size on the relative bias and relative root mean square error of the parameter estimates (rate and extent of pulmonary distribution). The optimized BAL sampling design depends on a characterized plasma concentration time profile, a population plasma pharmacokinetic model, the limit of quantification (LOQ) of the BAL method and involves only two BAL sample time points, one early and one late. The early sample should be taken as early as possible, where concentrations in the BAL fluid ≥ LOQ. The second sample should be taken at a time point in the declining part of the plasma curve, where the plasma concentration is equivalent to the plasma concentration in the early sample. Using a previously described general pulmonary distribution model linked to a plasma population pharmacokinetic model, simulated data using the final BAL sampling design enabled characterization of both the rate and extent of pulmonary distribution. The optimized BAL sampling design enables characterization of both the rate and extent of the pulmonary distribution for both fast and slowly equilibrating drugs.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.
Occurrence of ivermectin in bovine milk from the Brazilian retail market.
Lobato, V; Rath, S; Reyes, F G R
2006-07-01
High-performance liquid chromatography (HPLC) with fluorescence detection was used for the quantification of ivermectin residues in bovine milk intended for human consumption. After liquid-liquid extraction of ivermectin and purification of the extract, the compound was derivatized with 1-methylimidazol in N,N-dimethyl formamide to form a fluorescent derivative, which was separated by HPLC, using reversed-phase C18, with methanol : water (96 : 4 v/v) mobile phase at a flow rate 0.7 ml min-1. The excitation and emission wavelengths of the fluorescence detector were adjusted at 360 and 470 nm, respectively. The linearity of the method was in the range 10-100 ng ivermectin ml-1. Based on a sample of 5.0 ml, the limit of detection and the limit of quantification for ivermectin in milk were 0.6 and 2 ng ml-1, respectively. The recovery rate varied from 76.4 to 87.2%, with an average of 77.9 +/- 3.2%, at four fortification levels. The inter-day precision of the method was 13% (n = 5). Of 168 samples analysed, 17.8% contained ivermectin above the limit of quantification. Nevertheless, none of the samples contained ivermectin above the maximum residue limit (10 ng ml-1) established by the Brazilian Ministry of Agriculture.
Developing Reliable Telemedicine Platforms with Unreliable and Limited Communication Bandwidth
2017-10-01
hospital health care, the benefit of high -resolution medical data is greatly limited in battlefield or natural disaster areas, where communication to...sampling rate. For high - frequency data like waveforms, the downsampling approach could directly reduce the amount of data. Therefore, it could be used...AFRL-SA-WP-TR-2017-0019 Developing Reliable Telemedicine Platforms with Unreliable and Limited Communication Bandwidth Peter F
Hyung, Seok-Won; Piehowski, Paul D; Moore, Ronald J; Orton, Daniel J; Schepmoes, Athena A; Clauss, Therese R; Chu, Rosalie K; Fillmore, Thomas L; Brewer, Heather; Liu, Tao; Zhao, Rui; Smith, Richard D
2014-11-01
Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 μL) due to low yields stemming from losses caused by nonspecific binding to the column matrix and concentration of large eluent volumes. Additionally, the cost of the depletion media can be prohibitive for larger-scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large-scale studies. We characterized the performance of a 346 μL column volume microscale depletion system, using four different flow rates to determine the most effective depletion conditions for ∼6-μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10-mL depletion column served as the control. Results showed depletion efficiency of the microscale column increased as flow rate decreased, and that our microdepletion was reproducible. In an initial application, a 600-μL sample of human cerebrospinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.
Hyung, Seok Won; Piehowski, Paul D.; Moore, Ronald J.; ...
2014-09-06
Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizingmore » sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.« less
Performance of high flow rate samplers for respirable particle collection.
Lee, Taekhee; Kim, Seung Won; Chisholm, William P; Slaven, James; Harper, Martin
2010-08-01
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(-3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins-Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 microm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2-11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 microm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.
Performance of High Flow Rate Samplers for Respirable Particle Collection
Lee, Taekhee; Kim, Seung Won; Chisholm, William P.; Slaven, James; Harper, Martin
2010-01-01
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted. PMID:20660144
Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.
King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude
2006-09-01
Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.
Plasma Accelerator and Energy Conversion Research
1982-10-29
performance tests have been accomplished. A self-contained recirculating AMTEC device with a thermal to electric conversion efficiency of 19% has been...combined efficiency . These two match up particularly well, because thermionic conversion is a high temperature technique, whereas AMTEC is limited to...EXPERIENTAL: Samples: The samples were prepared with a high rate DC magnetron sputtering apparatus ( SFI model 1 ). The sample set consisted of four
Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate.
Karuppasamy, Manikandan; Karimi Nejadasl, Fatemeh; Vulovic, Milos; Koster, Abraham J; Ravelli, Raimond B G
2011-05-01
Radiation damage is an important resolution limiting factor both in macromolecular X-ray crystallography and cryo-electron microscopy. Systematic studies in macromolecular X-ray crystallography greatly benefited from the use of dose, expressed as energy deposited per mass unit, which is derived from parameters including incident flux, beam energy, beam size, sample composition and sample size. In here, the use of dose is reintroduced for electron microscopy, accounting for the electron energy, incident flux and measured sample thickness and composition. Knowledge of the amount of energy deposited allowed us to compare doses with experimental limits in macromolecular X-ray crystallography, to obtain an upper estimate of radical concentrations that build up in the vitreous sample, and to translate heat-transfer simulations carried out for macromolecular X-ray crystallography to cryo-electron microscopy. Stroboscopic exposure series of 50-250 images were collected for different incident flux densities and integration times from Lumbricus terrestris extracellular hemoglobin. The images within each series were computationally aligned and analyzed with similarity metrics such as Fourier ring correlation, Fourier ring phase residual and figure of merit. Prior to gas bubble formation, the images become linearly brighter with dose, at a rate of approximately 0.1% per 10 MGy. The gradual decomposition of a vitrified hemoglobin sample could be visualized at a series of doses up to 5500 MGy, by which dose the sample was sublimed. Comparison of equal-dose series collected with different incident flux densities showed a dose-rate effect favoring lower flux densities. Heat simulations predict that sample heating will only become an issue for very large dose rates (50 e(-)Å(-2) s(-1) or higher) combined with poor thermal contact between the grid and cryo-holder. Secondary radiolytic effects are likely to play a role in dose-rate effects. Stroboscopic data collection combined with an improved understanding of the effects of dose and dose rate will aid single-particle cryo-electron microscopists to have better control of the outcome of their experiments.
Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate
Karuppasamy, Manikandan; Karimi Nejadasl, Fatemeh; Vulovic, Milos; Koster, Abraham J.; Ravelli, Raimond B. G.
2011-01-01
Radiation damage is an important resolution limiting factor both in macromolecular X-ray crystallography and cryo-electron microscopy. Systematic studies in macromolecular X-ray crystallography greatly benefited from the use of dose, expressed as energy deposited per mass unit, which is derived from parameters including incident flux, beam energy, beam size, sample composition and sample size. In here, the use of dose is reintroduced for electron microscopy, accounting for the electron energy, incident flux and measured sample thickness and composition. Knowledge of the amount of energy deposited allowed us to compare doses with experimental limits in macromolecular X-ray crystallography, to obtain an upper estimate of radical concentrations that build up in the vitreous sample, and to translate heat-transfer simulations carried out for macromolecular X-ray crystallography to cryo-electron microscopy. Stroboscopic exposure series of 50–250 images were collected for different incident flux densities and integration times from Lumbricus terrestris extracellular hemoglobin. The images within each series were computationally aligned and analyzed with similarity metrics such as Fourier ring correlation, Fourier ring phase residual and figure of merit. Prior to gas bubble formation, the images become linearly brighter with dose, at a rate of approximately 0.1% per 10 MGy. The gradual decomposition of a vitrified hemoglobin sample could be visualized at a series of doses up to 5500 MGy, by which dose the sample was sublimed. Comparison of equal-dose series collected with different incident flux densities showed a dose-rate effect favoring lower flux densities. Heat simulations predict that sample heating will only become an issue for very large dose rates (50 e−Å−2 s−1 or higher) combined with poor thermal contact between the grid and cryo-holder. Secondary radiolytic effects are likely to play a role in dose-rate effects. Stroboscopic data collection combined with an improved understanding of the effects of dose and dose rate will aid single-particle cryo-electron microscopists to have better control of the outcome of their experiments. PMID:21525648
40 CFR 53.63 - Test procedure: Wind tunnel inlet aspiration test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the sampler inlet opening centered in the sampling zone. To meet the maximum blockage limit of § 53.62(c)(1) or for convenience, part of the test sampler may be positioned external to the wind tunnel... = reference method sampler volumetric flow rate; and t = sampling time. (iii) Remove the reference method...
Sharaf, J M; Hamideen, M S
2013-10-01
This study is undertaken to determine the activity concentration of (226)Ra, (232)Th and (40)K in samples of commonly used building materials in Jordan. Samples of seven different materials were collected from construction sites and local agencies supplying raw construction materials and analyzed using a HPGe gamma-ray spectrometer, taking into account self-attenuation in bulk samples. The average specific activity concentrations of (226)Ra, (232)Th, and (40)K ranged from 2.84 to 41.52, 0.78 to 58.42. and 3.74 to 897 Bq/kg, respectively. All the samples had radium equivalent activities well below the limit of 370 Bq/kg set by the Organization for Economic Cooperation and Development (OECD, 1979). External and internal hazard indices, absorbed dose and annual effective dose rate associated with the radionuclides of interest were calculated and compared with the international legislation and guidance. In general, most of the activities did not exceed the recommended international limits, except for granite and ceramic samples which are usually used as secondary building materials in Jordan. Copyright © 2013 Elsevier Ltd. All rights reserved.
Critical fluid light scattering
NASA Technical Reports Server (NTRS)
Gammon, Robert W.
1988-01-01
The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments were severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure fluctuation decay rates at least two decades closer to the critical point than is possible on earth, with a resolution of 3 microK. This will require loading the sample to 0.1 percent of the critical density and taking data as close as 100 microK to the critical temperature. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The experiment entails measurement of the scattering intensity fluctuation decay rate at two angles for each temperature and simultaneously recording the scattering intensities and sample turbidity (from the transmission). The analyzed intensity and turbidity data gives the correlation length at each temperature and locates the critical temperature. The fluctuation decay rate data from these measurements will provide a severe test of the generalized hydrodynamic theories of transport coefficients in the critical regions. When compared to equivalent data from binary liquid critical mixtures they will test the universality of critical dynamics.
Background: Soil/dust ingestion rates are important variables in assessing children’s health risks in contaminated environments. Current estimates are based largely on soil tracer methodology, which is limited by analytical uncertainty, small sample size, and short study du...
Baek, Hyun Jae; Shin, JaeWook; Jin, Gunwoo; Cho, Jaegeol
2017-10-24
Photoplethysmographic signals are useful for heart rate variability analysis in practical ambulatory applications. While reducing the sampling rate of signals is an important consideration for modern wearable devices that enable 24/7 continuous monitoring, there have not been many studies that have investigated how to compensate the low timing resolution of low-sampling-rate signals for accurate heart rate variability analysis. In this study, we utilized the parabola approximation method and measured it against the conventional cubic spline interpolation method for the time, frequency, and nonlinear domain variables of heart rate variability. For each parameter, the intra-class correlation, standard error of measurement, Bland-Altman 95% limits of agreement and root mean squared relative error were presented. Also, elapsed time taken to compute each interpolation algorithm was investigated. The results indicated that parabola approximation is a simple, fast, and accurate algorithm-based method for compensating the low timing resolution of pulse beat intervals. In addition, the method showed comparable performance with the conventional cubic spline interpolation method. Even though the absolute value of the heart rate variability variables calculated using a signal sampled at 20 Hz were not exactly matched with those calculated using a reference signal sampled at 250 Hz, the parabola approximation method remains a good interpolation method for assessing trends in HRV measurements for low-power wearable applications.
Occurrence of aflatoxin M1 in UHT milk in Turkey.
Unusan, Nurhan
2006-11-01
Aflatoxin M1 (AFM1) appears in milk as a direct result of the ingestion of food contaminated with aflatoxin B1 by cattle. The role of milk in human nutrition is well-known. The purpose of the study was to determine the levels of AFM1 in UHT milk samples in Central Anatolia, Turkey. The occurrence of AFM1 contamination in UHT milk samples was investigated by ELISA (Enzyme Linked Immunosorbent Assay) technique. A total of 129 samples of commercial UHT whole milk were analysed. The mean value was 108.17 ng/L. There was a high incidence rate of AFM1, with 75 (58.1%) milk samples being contaminated. Although 68 (53%) were below the limit, the remaining 61 (47%) were well above the limit permitted by the EU. Four of the samples exceeded the prescribed limit of US regulations. It can be concluded that AFM1 levels in the samples purchased in Central Anatolia Region, appear to be a serious public health problem at the moment. Dairy farmers must be educated by the government authorities on potential health consequences of aflatoxins.
Schuller, P; Walling, D E; Sepúlveda, A; Trumper, R E; Rouanet, J L; Pino, I; Castillo, A
2004-05-01
Intensification of agricultural production in south-central Chile since the 1970s has caused problems of increased soil erosion and associated soil degradation. These problems have prompted a shift from conventional tillage to no-till management practices. Faced with the need to establish the impact of this shift in soil management on rates of soil loss, the use of caesium-137 (137Cs) measurements has been explored. A novel procedure for using measurements of the 137Cs depth distribution to estimate rates of soil loss at a sampling point under the original conventional tillage and after the shift to no-till management has been developed. This procedure has been successfully applied to a study site at Buenos Aires farm near Carahue in the 9th region of Chile. The results obtained indicate that the shift from conventional tillage to no-till management has caused net rates of soil loss to decrease to about 40% of those existing under conventional tillage. This assessment of the impact of introducing no-till management at the study site must, however, be seen as provisional, since only a limited number of sampling points were used. A simplified procedure aimed at documenting the reduction in erosion rates at additional sampling points, based solely on measurements of the 137Cs inventory of bulk cores and the 137Cs activity in the upper part of the soil has been developed and successfully tested at the study site. Previous application of 137Cs measurements to estimate erosion rates has been limited to estimation of medium-term erosion rates during the period extending from the beginning of fallout receipt to the time of sampling. The procedures described in this paper, which permits estimation of the change in erosion rates associated with a shift in land management practices, must be seen as representing a novel application of 137Cs measurements in soil erosion investigations.
NASA Astrophysics Data System (ADS)
Chen, Daniel; Chen, Damian; Yen, Ray; Cheng, Mingjen; Lan, Andy; Ghaskadvi, Rajesh
2008-11-01
Identifying hotspots--structures that limit the lithography process window--become increasingly important as the industry relies heavily on RET to print sub-wavelength designs. KLA-Tencor's patented Process Window Qualification (PWQ) methodology has been used for this purpose in various fabs. PWQ methodology has three key advantages (a) PWQ Layout--to obtain the best sensitivity (b) Design Based Binning--for pattern repeater analysis (c) Intelligent sampling--for the best DOI sampling rate. This paper evaluates two different analysis strategies for SEM review sampling successfully deployed at Inotera Memories, Inc. We propose a new approach combining the location repeater and pattern repeaters. Based on a recent case study the new sampling flow reduces the data analysis and sampling time from 6 hours to 1.5 hour maintaining maximum DOI sample rate.
West, Robert; Pesce, Amadeo; West, Cameron; Crews, Bridgit; Mikel, Charles; Almazan, Perla; Rosenthal, Murray; Latyshev, Sergey
2010-01-01
Physicians determine patient compliance with their medications by use of urine drug testing. It is known that measurement of benzodiazepines is limited by immunoassay specificity and cutoff limits and therefore does not offer physicians an accurate picture of their patients' compliance with these medications. A few studies have used lower cutoffs to demonstrate patient compliance. To define more appropriate cutoffs for compliance monitoring of patients prescribed clonazepam as determined using immunoassay and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A diagnostic accuracy study of the urinary excretion of clonazepam. Millennium Laboratories performed measurements on the urinary excretion of pain patients prescribed clonazepam as the indicator test. This benzodiazepine was chosen because it forms one major metabolite, 7-aminoclonazepam which is specific for that drug. Patients whose only benzodiazepine medication was clonazepam were selected as the test population. The Millennium Laboratories test database was filtered first to select patients on clonazepam, then a second filter was used to eliminate patients with any other listed benzodiazepine medications. Samples were tested using the Microgenics DRI benzodiazepine assay with a 200 ng/mL cutoff. The same samples were quantitatively assessed for 7-aminoclonazepam by LC-MS/MS with a cutoff of 40 ng/mL. The results from the immunoassay were scored as positive or negative while the quantitative results from the LC-MS/MS were also scored as positive or negative depending upon their concentration. Samples from 180 patients met these medication criteria. The positivity rates were 21% (38 samples) by immunoassay. The positivity rate was 70% (126 samples) if the LC-MS/MS cutoff was set at 200 ng/mL. However, the positivity rate was 87% (157 samples) if the LC-MS/MS was set at 40 ng/mL. Concentration distributions revealed a significant fraction (7%) in the 40 - 100 ng/mL range. A limitation of the study was the inability to measure lower than 40 ng/mL. There may be another fraction of the population that was positive below the cutoff value. The difference in positivity rate between the immunoassay and the LC-MS/MS result showed that the nominal 200 ng/mL cutoff of the immunoassay did not apply to 7-aminoclonazepam. This low immunoassay positivity rate is inconsistent with the manufacturer's published cross reactivity data for clonazepam and 7-aminoclonazepam. These data illustrate the limitations of using a 200 ng/mL cutoff to monitor clonazepam compliance and suggest that a cutoff of 40 ng/mL or less is needed to reliably monitor use of this drug.
Barua, Suman; Rahman, Ismail M M; Alam, Iftakharul; Miyaguchi, Maho; Sawai, Hikaru; Maki, Teruya; Hasegawa, Hiroshi
2017-08-15
A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λ max =405.8nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5ng mL -1 , respectively. The precision, as relative standard deviation, was lower than 5% at 0.1μg mL -1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate:>95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5min, without preconcentration) with a reliable detection limit at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.
Hutchison, J R; Piepel, G F; Amidan, B G; Hess, B M; Sydor, M A; Deatherage Kaiser, B L
2018-05-01
We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials and assay methods on false-negative rate (FNR) and limit of detection (LOD 95 ) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2-500 per coupon) onto glass, stainless steel, vinyl tile and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD 95 results. Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD 95 was lowest for glass and highest for vinyl tile. LOD 95 values overall were lower for mRV-PCR than for the culture method. This study adds to the limited data on FNR and LOD 95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis. © 2018 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Bilge, Gonca; Sezer, Banu; Boyaci, Ismail Hakki; Eseller, Kemal Efe; Berberoglu, Halil
2018-07-01
Liquid analysis by using LIBS is a complicated process due to difficulties encountered during the collection of light and formation of plasma in liquid. To avoid these, some applications are performed such as aerosol formation and transforming liquid into solid state. However, performance of LIBS in liquid samples still remains a challenging issue. In this study, performance evaluation of LIBS and parameter optimizations in liquid and solid phase samples were performed. For this purpose, milk was chosen as model sample; milk powder was used as solid sample, and milk was used as liquid sample in the experiments. Different experimental setups have been constructed for each sampling technique, and optimizations were performed to determine suitable parameters such as delay time, laser energy, repetition rate and speed of rotary table for solid sampling technique, and flow rate of carrier gas for liquid sampling technique. Target element was determined as Ca, which is a critically important element in milk for determining its nutritional value and Ca addition. In optimum parameters, limit of detection (LOD), limit of quantification (LOQ) and relative standard deviation (RSD) values were calculated as 0.11%, 0.36% and 8.29% respectively for milk powders samples; while LOD, LOQ and RSD values were calculated as 0.24%, 0.81%, and 10.93% respectively for milk samples. It can be said that LIBS is an applicable method in both liquid and solid samples with suitable systems and parameters. However, liquid analysis requires much more developed systems for more accurate results.
Direct Measurement of the Flip-Flop Rate of Electron Spins in the Solid State
NASA Astrophysics Data System (ADS)
Dikarov, Ekaterina; Zgadzai, Oleg; Artzi, Yaron; Blank, Aharon
2016-10-01
Electron spins in solids have a central role in many current and future spin-based devices, ranging from sensitive sensors to quantum computers. Many of these apparatuses rely on the formation of well-defined spin structures (e.g., a 2D array) with controlled and well-characterized spin-spin interactions. While being essential for device operation, these interactions can also result in undesirable effects, such as decoherence. Arguably, the most important pure quantum interaction that causes decoherence is known as the "flip-flop" process, where two interacting spins interchange their quantum state. Currently, for electron spins, the rate of this process can only be estimated theoretically, or measured indirectly, under limiting assumptions and approximations, via spin-relaxation data. This work experimentally demonstrates how the flip-flop rate can be directly and accurately measured by examining spin-diffusion processes in the solid state for physically fixed spins. Under such terms, diffusion can occur only through this flip-flop-mediated quantum-state exchange and not via actual spatial motion. Our approach is implemented on two types of samples, phosphorus-doped 28Si and nitrogen vacancies in diamond, both of which are significantly relevant to quantum sensors and information processing. However, while the results for the former sample are conclusive and reveal a flip-flop rate of approximately 12.3 Hz, for the latter sample only an upper limit of approximately 0.2 Hz for this rate can be estimated.
Investigation of spectral analysis techniques for randomly sampled velocimetry data
NASA Technical Reports Server (NTRS)
Sree, Dave
1993-01-01
It is well known that velocimetry (LV) generates individual realization velocity data that are randomly or unevenly sampled in time. Spectral analysis of such data to obtain the turbulence spectra, and hence turbulence scales information, requires special techniques. The 'slotting' technique of Mayo et al, also described by Roberts and Ajmani, and the 'Direct Transform' method of Gaster and Roberts are well known in the LV community. The slotting technique is faster than the direct transform method in computation. There are practical limitations, however, as to how a high frequency and accurate estimate can be made for a given mean sampling rate. These high frequency estimates are important in obtaining the microscale information of turbulence structure. It was found from previous studies that reliable spectral estimates can be made up to about the mean sampling frequency (mean data rate) or less. If the data were evenly samples, the frequency range would be half the sampling frequency (i.e. up to Nyquist frequency); otherwise, aliasing problem would occur. The mean data rate and the sample size (total number of points) basically limit the frequency range. Also, there are large variabilities or errors associated with the high frequency estimates from randomly sampled signals. Roberts and Ajmani proposed certain pre-filtering techniques to reduce these variabilities, but at the cost of low frequency estimates. The prefiltering acts as a high-pass filter. Further, Shapiro and Silverman showed theoretically that, for Poisson sampled signals, it is possible to obtain alias-free spectral estimates far beyond the mean sampling frequency. But the question is, how far? During his tenure under 1993 NASA-ASEE Summer Faculty Fellowship Program, the author investigated from his studies on the spectral analysis techniques for randomly sampled signals that the spectral estimates can be enhanced or improved up to about 4-5 times the mean sampling frequency by using a suitable prefiltering technique. But, this increased bandwidth comes at the cost of the lower frequency estimates. The studies further showed that large data sets of the order of 100,000 points, or more, high data rates, and Poisson sampling are very crucial for obtaining reliable spectral estimates from randomly sampled data, such as LV data. Some of the results of the current study are presented.
ERIC Educational Resources Information Center
McDermott, Michael J.; Drescher, Christopher F.; Smitherman, Todd A.; Tull, Matthew T.; Heiden, Laurie; Damon, John D.; Hight, Terry L.; Young, John
2013-01-01
Background: Data are limited regarding the prevalence of substance use among adolescents in rural and ethnically diverse communities. This study examined rates and sociodemographic correlates of lifetime substance use among adolescents in Mississippi, a rural state that is the poorest in the country (21.3% poverty rate) and has the largest…
The structured ancestral selection graph and the many-demes limit.
Slade, Paul F; Wakeley, John
2005-02-01
We show that the unstructured ancestral selection graph applies to part of the history of a sample from a population structured by restricted migration among subpopulations, or demes. The result holds in the limit as the number of demes tends to infinity with proportionately weak selection, and we have also made the assumptions of island-type migration and that demes are equivalent in size. After an instantaneous sample-size adjustment, this structured ancestral selection graph converges to an unstructured ancestral selection graph with a mutation parameter that depends inversely on the migration rate. In contrast, the selection parameter for the population is independent of the migration rate and is identical to the selection parameter in an unstructured population. We show analytically that estimators of the migration rate, based on pairwise sequence differences, derived under the assumption of neutrality should perform equally well in the presence of weak selection. We also modify an algorithm for simulating genealogies conditional on the frequencies of two selected alleles in a sample. This permits efficient simulation of stronger selection than was previously possible. Using this new algorithm, we simulate gene genealogies under the many-demes ancestral selection graph and identify some situations in which migration has a strong effect on the time to the most recent common ancestor of the sample. We find that a similar effect also increases the sensitivity of the genealogy to selection.
Ji, Ho-Il; Davenport, Timothy C.; Gopal, Chirranjeevi Balaji; ...
2016-07-18
The redox kinetics of undoped ceria (CeO 2-δ) are investigated by the electrical conductivity relaxation method in the oxygen partial pressure range of -4.3 ≤ log(pO 2/atm) ≤ -2.0 at 1400 °C. It is demonstrated that extremely large gas flow rates, relative to the mass of the oxide, are required in order to overcome gas phase limitations and access the material kinetic properties. Using these high flow rate conditions, the surface reaction rate constant k chem is found to obey the correlation log(k chem/cm s -1) = (0.84 ± 0.02) × log(pO 2/atm) - (0.99 ± 0.05) and increases withmore » oxygen partial pressure. This increase contrasts the known behavior of the dominant defect species, oxygen vacancies and free electrons, which decrease in concentration with increasing oxygen partial pressure. For the sample geometries employed, diffusion was too fast to be detected. At low gas flow rates, the relaxation process becomes limited by the capacity of the sweep gas to supply/remove oxygen to/from the oxide. An analytical expression is derived for the relaxation in the gas-phase limited regime, and the result reveals an exponential decay profile, identical in form to that known for a surface reaction limited process. Thus, measurements under varied gas flow rates are required to differentiate between surface reaction limited and gas flow limited behavior.« less
Ji, Ho-Il; Davenport, Timothy C; Gopal, Chirranjeevi Balaji; Haile, Sossina M
2016-08-03
The redox kinetics of undoped ceria (CeO2-δ) are investigated by the electrical conductivity relaxation method in the oxygen partial pressure range of -4.3 ≤ log(pO2/atm) ≤ -2.0 at 1400 °C. It is demonstrated that extremely large gas flow rates, relative to the mass of the oxide, are required in order to overcome gas phase limitations and access the material kinetic properties. Using these high flow rate conditions, the surface reaction rate constant kchem is found to obey the correlation log(kchem/cm s(-1)) = (0.84 ± 0.02) × log(pO2/atm) - (0.99 ± 0.05) and increases with oxygen partial pressure. This increase contrasts the known behavior of the dominant defect species, oxygen vacancies and free electrons, which decrease in concentration with increasing oxygen partial pressure. For the sample geometries employed, diffusion was too fast to be detected. At low gas flow rates, the relaxation process becomes limited by the capacity of the sweep gas to supply/remove oxygen to/from the oxide. An analytical expression is derived for the relaxation in the gas-phase limited regime, and the result reveals an exponential decay profile, identical in form to that known for a surface reaction limited process. Thus, measurements under varied gas flow rates are required to differentiate between surface reaction limited and gas flow limited behavior.
An Analysis Of Coast Guard Enlisted Retention
1993-03-01
Instrument Identification Number(i f applicable , Address (cirv. state, and ZIP code) 10 Source of Funding Numbers Program Element No Project No ITask...46 E. SAMPLE RESTRICTIONS ........ .............. 48 F. DATA LIMITATIONS AND PROBLEMS ... ......... .. 52 1. PMIS Data Base...civilian employment suggest retention behavior may be similar. Also, the small personnel inventories of some of the rates would limit the model’s
Optimization of a mist chamber (Cofer scrubber) for sampling water-soluble organics in air.
Spaulding, Reggie S; Talbot, Robert W; Charles, M Judith
2002-04-15
While the atmospheric fate and transport of biogenic and anthropogenic hydrocarbons has been extensively studied, little is known about the behavior of first-, second-, and third generation photo-oxidation products that arise from OH radical oxidation of the parent species. The results of chamber experiments establish that *OH oxidation of biogenic and anthropogenic hydrocarbons yields carbonyls, dicarbonyls, hydroxycarbonyls, and keto-acids. However, little is known about the generation and fate of these products in the ambient atmospheric environment. This is changing because of the advent of methods that rely on 0-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) derivatization of carbonyls in concert with gas chromatography/ion trap mass spectrometry. Such methods provide the means to identify and quantify water-soluble organics, which historically have been difficult to measure. A limitation of existing sampling methods, however, is the use of devices that require low flow rates (0.5-1 L min(-1)). Accordingly, long sampling times (3-4 h) are needed to obtain pptv-ppbv detection limits. The mist chamber is an attractive device because of the high flow rates (25-70 L min(-1)) compatible with its use. Herein, we evaluate a mist chamber using a flow rate of 25-30 L min(-1) to provide short (10 min) sampling times and pptv limits of detection. The results establish a relationship between the Henry's law constant (KH) and the collection efficiency and demonstrate the suitability of the method to measure analytes with KH > or = 10(3) M atm(-1). Adjusting the pH, adding quaternary ammonium salts, or decreasing the temperature of the collecting solution in the mist chamber did not significantly affect the collection efficiency. We tested the method by sampling photooxidation products of isoprene (glyoxal, methylglyoxal, hydroxyacetone, and glycolaldehyde) in the Blodgett Forest, CA. This is the first report of a study the employs the mist chamberto sample hydroxycarbonyls. The accuracy and the reproducibility of the method were evaluated by the analysis of duplicate samples and field spikes. The mean recovery of field spikes was > or =80%, and the relative standard deviation was < or =22% between duplicate measurements. The detection limits were 48, 15, 7.7, and 2.7 pptv for glycolaldehyde, hydroxyacetone, methylglyoxal, and glyoxal, respectively. This work demonstrates the power of the mist chamber in concert with PFBHA derivatization and mass spectrometry to measure pptv concentrations of water-soluble organics with a sampling time of 10 min.
Limits on rock strength under high confinement
NASA Astrophysics Data System (ADS)
Renshaw, Carl E.; Schulson, Erland M.
2007-06-01
Understanding of deep earthquake source mechanisms requires knowledge of failure processes active under high confinement. Under low confinement the compressive strength of rock is well known to be limited by frictional sliding along stress-concentrating flaws. Under higher confinement strength is usually assumed limited by power-law creep associated with the movement of dislocations. In a review of existing experimental data, we find that when the confinement is high enough to suppress frictional sliding, rock strength increases as a power-law function only up to a critical normalized strain rate. Within the regime where frictional sliding is suppressed and the normalized strain rate is below the critical rate, both globally distributed ductile flow and localized brittle-like failure are observed. When frictional sliding is suppressed and the normalized strain rate is above the critical rate, failure is always localized in a brittle-like manner at a stress that is independent of the degree of confinement. Within the high-confinement, high-strain rate regime, the similarity in normalized failure strengths across a variety of rock types and minerals precludes both transformational faulting and dehydration embrittlement as strength-limiting mechanisms. The magnitude of the normalized failure strength corresponding to the transition to the high-confinement, high-strain rate regime and the observed weak dependence of failure strength on strain rate within this regime are consistent with a localized Peierls-type strength-limiting mechanism. At the highest strain rates the normalized strengths approach the theoretical limit for crystalline materials. Near-theoretical strengths have previously been observed only in nano- and micro-scale regions of materials that are effectively defect-free. Results are summarized in a new deformation mechanism map revealing that when confinement and strain rate are sufficient, strengths approaching the theoretical limit can be achieved in cm-scale sized samples of rocks rich in defects. Thus, non-frictional failure processes must be considered when interpreting rock deformation data collected under high confinement and low temperature. Further, even at higher temperatures the load-bearing ability of crustal rocks under high confinement may not be limited by a frictional process under typical geologic strain rates.
Johnson, Derrick E.; Xue, Bin; Sickmeier, Megan D.; Meng, Jingwei; Cortese, Marc S.; Oldfield, Christopher J.; Le Gall, Tanguy; Dunker, A. Keith; Uversky, Vladimir N.
2012-01-01
The identification of intrinsically disordered proteins (IDPs) among the targets that fail to form satisfactory crystal structures in the Protein Structure Initiative represent a key to reducing the costs and time for determining three-dimensional structures of proteins. To help in this endeavor, several Protein Structure Initiative Centers were asked to send samples of both crystallizable proteins and proteins that failed to crystallize. The abundance of intrinsic disorder in these proteins was evaluated via computational analysis using Predictors of Natural Disordered Regions (PONDR®) and the potential cleavage sites and corresponding fragments were determined. Then, the target proteins were analyzed for intrinsic disorder by their resistance to limited proteolysis. The rates of tryptic digestion of sample target proteins were compared to those of lysozyme/myoglobin, apo-myoglobin and α-casein as standards of ordered, partially disordered and completely disordered proteins, respectively. At the next stage, the protein samples were subjected to both far-UV and near-UV circular dichroism (CD) analysis. For most of the samples, a good agreement between CD data, predictions of disorder and the rates of limited tryptic digestion was established. Further experimentation is being performed on a smaller subset of these samples in order to obtain more detailed information on the ordered/disordered nature of the proteins. PMID:22651963
Real-time quantum cascade laser-based infrared microspectroscopy in-vivo
NASA Astrophysics Data System (ADS)
Kröger-Lui, N.; Haase, K.; Pucci, A.; Schönhals, A.; Petrich, W.
2016-03-01
Infrared microscopy can be performed to observe dynamic processes on a microscopic scale. Fourier-transform infrared spectroscopy-based microscopes are bound to limitations regarding time resolution, which hampers their potential for imaging fast moving systems. In this manuscript we present a quantum cascade laser-based infrared microscope which overcomes these limitations and readily achieves standard video frame rates. The capabilities of our setup are demonstrated by observing dynamical processes at their specific time scales: fermentation, slow moving Amoeba Proteus and fast moving Caenorhabditis elegans. Mid-infrared sampling rates between 30 min and 20 ms are demonstrated.
Relative toxicity of pyrolysis products of some foams and fabrics
NASA Technical Reports Server (NTRS)
Hilado, C. J.
1976-01-01
A limited number of foams and fabrics was evaluated in the course of developing test procedures for determining the relative toxicity of materials. The principal variable studied, heating rate, did not affect the relative ranking of the materials tested. Two pyrolysis test procedures using the same basic approach but employing different sample weights, chamber volumes, laboratory animals, heating rates, and upper temperature limits, resulted in identical rankings of relative toxicity. The data obtained show that modification of conventional flexible polyurethane foams with flame retardants to comply with California upholstered furniture flammability regulations seems to consistently reduce toxicity under pyrolysis conditions.
A passive sampler for airborne formaldehyde
NASA Astrophysics Data System (ADS)
Grosjean, Daniel; Williams, Edwin L.
A simple, inexpensive passive sampler is described that is capable of reliable measurements of formaldehyde at the parts per billion (ppb) levels relevant to indoor and outdoor air quality. The passive sampler consists of a modified dual filter holder in which the upper stage serves as the diffusion barrier, the lower stage includes a 2,4-dinitrophenylhydrazine (DNPH)-coated filter which collects formaldehyde, and the space between the two stages serve as the diffusion gap. The measured sampling rate, 18.8 ± 1.8 ml min -1, was determined in experiments involving sampling of ppb levels of formaldehyde with the passive sampler and with DNPH-coated C 18 cartridges and agrees well with the value of 19.4 ± 2.0 ml min -1 calculated from theory. The measured sampling rate was independent of formaldehyde concentration (16-156 ppb) and sampling duration (1.5-72 h). The precision of the measurements for colocated passive samplers averaged 8.6% in purified and indoor air (office and museums) and 10.2% in photochemically polluted outdoor air. With a 1.2-μm pore size Teflon filter as the diffusion barrier, the detection limit is 32 ppb h, e.g. 4 ppb in an 8-h sample, 1.3 ppb in a 24-h sample, and so on. Perceived advantages and limitations of the sampler are discussed including flexibility, cost effectiveness and possible negative bias at high ambient levels of ozone.
An on-line pre-concentration system for determination of cadmium in drinking water using FAAS.
dos Santos, Walter N L; Costa, Jorge L O; Araujo, Rennan G O; de Jesus, Djane S; Costa, Antônio C S
2006-10-11
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L(-1) and elution concentration of 1.0 mol L(-1), this system allows the determination of cadmium with detection limit (LD) (3sigma/S) of 20.0 ng L(-1) and quantification limit (LQ) (10sigma/S) of 64 ng L(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 microg L(-1), respectively, and a pre-concentration factor of 158 for a sample volume of 20.0 mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 microg L(-1).
Effects of Sampling and Spatio/Temporal Granularity in Traffic Monitoring on Anomaly Detectability
NASA Astrophysics Data System (ADS)
Ishibashi, Keisuke; Kawahara, Ryoichi; Mori, Tatsuya; Kondoh, Tsuyoshi; Asano, Shoichiro
We quantitatively evaluate how sampling and spatio/temporal granularity in traffic monitoring affect the detectability of anomalous traffic. Those parameters also affect the monitoring burden, so network operators face a trade-off between the monitoring burden and detectability and need to know which are the optimal paramter values. We derive equations to calculate the false positive ratio and false negative ratio for given values of the sampling rate, granularity, statistics of normal traffic, and volume of anomalies to be detected. Specifically, assuming that the normal traffic has a Gaussian distribution, which is parameterized by its mean and standard deviation, we analyze how sampling and monitoring granularity change these distribution parameters. This analysis is based on observation of the backbone traffic, which exhibits spatially uncorrelated and temporally long-range dependence. Then we derive the equations for detectability. With those equations, we can answer the practical questions that arise in actual network operations: what sampling rate to set to find the given volume of anomaly, or, if the sampling is too high for actual operation, what granularity is optimal to find the anomaly for a given lower limit of sampling rate.
Munchel, Sarah; Hoang, Yen; Zhao, Yue; Cottrell, Joseph; Klotzle, Brandy; Godwin, Andrew K; Koestler, Devin; Beyerlein, Peter; Fan, Jian-Bing; Bibikova, Marina; Chien, Jeremy
2015-09-22
Current genomic studies are limited by the poor availability of fresh-frozen tissue samples. Although formalin-fixed diagnostic samples are in abundance, they are seldom used in current genomic studies because of the concern of formalin-fixation artifacts. Better characterization of these artifacts will allow the use of archived clinical specimens in translational and clinical research studies. To provide a systematic analysis of formalin-fixation artifacts on Illumina sequencing, we generated 26 DNA sequencing data sets from 13 pairs of matched formalin-fixed paraffin-embedded (FFPE) and fresh-frozen (FF) tissue samples. The results indicate high rate of concordant calls between matched FF/FFPE pairs at reference and variant positions in three commonly used sequencing approaches (whole genome, whole exome, and targeted exon sequencing). Global mismatch rates and C · G > T · A substitutions were comparable between matched FF/FFPE samples, and discordant rates were low (<0.26%) in all samples. Finally, low-pass whole genome sequencing produces similar pattern of copy number alterations between FF/FFPE pairs. The results from our studies suggest the potential use of diagnostic FFPE samples for cancer genomic studies to characterize and catalog variations in cancer genomes.
An upper limit on ultraviolet shot noise from Cygnus X-1
NASA Technical Reports Server (NTRS)
Duthie, J. G.; Mcmillan, R. S.
1979-01-01
Rapid photometry of Cygnus X-1 through an ultraviolet filter centered on 0.35 micron has been obtained at 100-ms sampling intervals. The autocorrelation function of these data has been examined for shot noise analogous to the behavior of the X-ray light curve. The ultraviolet data are entirely consistent with white noise. Considering randomly occurring ultraviolet shots with the same duration (0.5 s) and average rate (1 per sec) as the X-ray shots, a 3-sigma upper limit on the ratio of optical to X-ray energies per shot is estimated to be 0.13, before the ultraviolet light is attenuated by interstellar dust. This limit is then generalized for shots of arbitrary duration and rate.
The forensiX evidence collection tube and its impact on DNA preservation and recovery.
Garvin, Alex M; Holzinger, Ralf; Berner, Florian; Krebs, Walter; Hostettler, Bernhard; Lardi, Elges; Hertli, Christian; Quartermaine, Roy; Stamm, Christoph
2013-01-01
Biological samples are vulnerable to degradation from the time they are collected until they are analysed at the laboratory. Biological contaminants, such as bacteria, fungi, and enzymes, as well as environmental factors, such as sunlight, heat, and humidity, can increase the rate of DNA degradation. Currently, DNA samples are normally dried or frozen to limit their degradation prior to their arrival at the laboratory. In this study, the effect of the sample drying rate on DNA preservation was investigated, as well as a comparison between drying and freezing methods. The drying performances of two commercially available DNA collection tools (swab and drying tube) with different drying rates were evaluated. The swabs were used to collect human saliva, placed into the drying tubes, and stored in a controlled environment at 25°C and 60% relative humidity, or frozen at -20°C, for 2 weeks. Swabs that were stored in fast sample drying tubes yielded 95% recoverable DNA, whereas swabs stored in tubes with slower sample drying rates yielded only 12% recoverable DNA; saliva stored in a microtube at -20°C was used as a control. Thus, DNA sampling tools that offer rapid drying can significantly improve the preservation of DNA collected on a swab, increasing the quantity of DNA available for subsequent analysis.
NASA Astrophysics Data System (ADS)
Kumar, Ajay; Vij, Raman; Sharma, Sumit; Sarin, Amit; Narang, Saurabh
2018-02-01
Because to extensive utilization of soil as a building/construction stuff, the activities of 238U, 40K, 232Th, and exhalation studies in solid samples have been measured using thallium activated sodium iodide (NaI(Tl)) gamma detector and scintillation-based smart RnDuo monitor. The measured activity concentration of radionuclides lies in the range of 2.76-38.96, 12.47-65.70, and 199-450 Bq/kg for uranium (C U), thorium (C Th), and potassium (C K), respectively. The annual effective dose rate due to radionuclides is within the secure limit suggested by ICRP. The radium equivalent activity of all the samples is under 100 Bq/kg. The maximum outward and inside risk indices of all these samples are below the values of 0.37 and 0.43. No direct correlation has been seen between 238U and its mass exhalation rate as well as 232Th and its surface exhalation rate in soil samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchison, J. R.; Piepel, G. F.; Amidan, B. G.
Aims: We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials, and assay methods on false-negative rate (FNR) and limit of detection (LOD95) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Methods and Results: Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2 – 500 coupon-1) onto glass, stainless steel, vinyl tile, and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. Conclusions: Mean FNRs tended to be lower for mRV-PCR compared tomore » culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. Significance and Impact of Study: This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.« less
In-vivo digital wavefront sensing using swept source OCT
Kumar, Abhishek; Wurster, Lara M.; Salas, Matthias; Ginner, Laurin; Drexler, Wolfgang; Leitgeb, Rainer A.
2017-01-01
Sub-aperture based digital adaptive optics is demonstrated in a fiber based point scanning optical coherence tomography system using a 1060 nm swept source laser. To detect optical aberrations in-vivo, a small lateral field of view of ~150×150 μm2 is scanned on the sample at a high volume rate of 17 Hz (~1.3 kHz B-scan rate) to avoid any significant lateral and axial motion of the sample, and is used as a “guide star” for the sub-aperture based DAO. The proof of principle is demonstrated using a micro-beads phantom sample, wherein a significant root mean square wavefront error (RMS WFE) of 1.48 waves (> 1μm) is detected. In-vivo aberration measurement with a RMS WFE of 0.33 waves, which is ~5 times higher than the Marechal’s criterion of 1/14 waves for the diffraction limited performance, is shown for a human retinal OCT. Attempt has been made to validate the experimental results with the conventional Shack-Hartmann wavefront sensor within reasonable limitations. PMID:28717573
Sparse imaging for fast electron microscopy
NASA Astrophysics Data System (ADS)
Anderson, Hyrum S.; Ilic-Helms, Jovana; Rohrer, Brandon; Wheeler, Jason; Larson, Kurt
2013-02-01
Scanning electron microscopes (SEMs) are used in neuroscience and materials science to image centimeters of sample area at nanometer scales. Since imaging rates are in large part SNR-limited, large collections can lead to weeks of around-the-clock imaging time. To increase data collection speed, we propose and demonstrate on an operational SEM a fast method to sparsely sample and reconstruct smooth images. To accurately localize the electron probe position at fast scan rates, we model the dynamics of the scan coils, and use the model to rapidly and accurately visit a randomly selected subset of pixel locations. Images are reconstructed from the undersampled data by compressed sensing inversion using image smoothness as a prior. We report image fidelity as a function of acquisition speed by comparing traditional raster to sparse imaging modes. Our approach is equally applicable to other domains of nanometer microscopy in which the time to position a probe is a limiting factor (e.g., atomic force microscopy), or in which excessive electron doses might otherwise alter the sample being observed (e.g., scanning transmission electron microscopy).
Modular design and implementation of field-programmable-gate-array-based Gaussian noise generator
NASA Astrophysics Data System (ADS)
Li, Yuan-Ping; Lee, Ta-Sung; Hwang, Jeng-Kuang
2016-05-01
The modular design of a Gaussian noise generator (GNG) based on field-programmable gate array (FPGA) technology was studied. A new range reduction architecture was included in a series of elementary function evaluation modules and was integrated into the GNG system. The approximation and quantisation errors for the square root module with a first polynomial approximation were high; therefore, we used the central limit theorem (CLT) to improve the noise quality. This resulted in an output rate of one sample per clock cycle. We subsequently applied Newton's method for the square root module, thus eliminating the need for the use of the CLT because applying the CLT resulted in an output rate of two samples per clock cycle (>200 million samples per second). Two statistical tests confirmed that our GNG is of high quality. Furthermore, the range reduction, which is used to solve a limited interval of the function approximation algorithms of the System Generator platform using Xilinx FPGAs, appeared to have a higher numerical accuracy, was operated at >350 MHz, and can be suitably applied for any function evaluation.
Osman, Amira; Walsemann, Katrina M
2013-04-01
We examined the contribution of socioeconomic disadvantage and traumatic life events to ethnic disparities in disability among Israeli adults. We used data from the Survey of Health, Aging and Retirement in Europe (SHARE-Israel), a sample of Israeli adults aged 50 or older (N = 1,546). Disability measures included functional limitations, limitations in activities of daily living (ADL), and limitations in instrumental activities of daily living (IADL). Arabs and immigrants from the Former Soviet Union (FSU) experienced higher rates of functional limitations and limitations in IADLs compared to veteran Jews. The rate of having limitations in ADLs was similar for Arabs and veteran Jews, but was higher for FSU immigrants compared to veteran Jews. Inclusion of education, income, and traumatic life events attenuated, but did not eliminate ethnic disparities in disability. Identifying factors driving ethnic health disparities in Israel is imperative if we hope to achieve health equity.
Ibrahim, Imtiaz; Togola, Anne; Gonzalez, Catherine
2013-06-01
Polar organic chemical integrative samplers (POCIS) are useful for monitoring a wide range of chemicals, including polar pesticides, in water bodies. However, few calibration data are available, which limits the use of these samplers for time-weighted average concentration measurements in an aquatic medium. This work deals with the laboratory calibration of the pharmaceutical configuration of a polar organic chemical integrative sampler (pharm-POCIS) for calculating the sampling rates of 17 polar pesticides (1.15 ≤ logK(ow) ≤ 3.71) commonly found in water. The experiment, conducted for 21 days in a continuous water flow-through exposure system, showed an integrative accumulation of all studied pesticides for 15 days. Three compounds (metalaxyl, azoxystrobine, and terbuthylazine) remained integrative for the 21-day experiment. The sampling rates measured ranged from 67.9 to 279 mL day(-1) and increased with the hydrophobicity of the pesticides until reaching a plateau where no significant variation in sampling rate is observed when increasing the hydrophobicity.
NASA Astrophysics Data System (ADS)
Larichkin, A.; Zakharchenko, K.; Gorev, B.; Kapustin, V.; Maksimovskiy, E.
2017-10-01
Influence of conditions of technological process of forming thick panels of a given geometry on fatigue limit of flat specimens from the V95ochT2 and V95pchT2 (analogues 7475 and 7175T76) alloys (Al-Mg-Cu-Zn) has been analysed. The process has been simulated experimentally on flat samples for temperatures 20, 165 and 420°C. The process includes: non-elastic strain in the range 10-5 - 10-2 s-1 up to 2% of total strain, followed by heat treatment according to T2 mode (quenching and aging). Fatigue life tests were carried out both on solid samples and on samples with a hole. It has been shown that resistance to fatigue of the observed alloys after forming at the annealing temperature (420°C) is comparable to the basic material resistance to fatigue. Meso-structure analysis showed absence of stress in grains. It is established that, on average, the shape of the grains is the same for a series of samples for different temperatures and loading rates. The results of testing samples with a hole showed that fatigue limit slightly decreases in samples which were previously deformed at (420°C), with respect to the durability of samples from the material in basic state. With an increase in rate of pre-strain, the relative number of cycles before destruction occurs increased.
Kalb, Daniel M; Fencl, Frank A; Woods, Travis A; Swanson, August; Maestas, Gian C; Juárez, Jaime J; Edwards, Bruce S; Shreve, Andrew P; Graves, Steven W
2017-09-19
Flow cytometry provides highly sensitive multiparameter analysis of cells and particles but has been largely limited to the use of a single focused sample stream. This limits the analytical rate to ∼50K particles/s and the volumetric rate to ∼250 μL/min. Despite the analytical prowess of flow cytometry, there are applications where these rates are insufficient, such as rare cell analysis in high cellular backgrounds (e.g., circulating tumor cells and fetal cells in maternal blood), detection of cells/particles in large dilute samples (e.g., water quality, urine analysis), or high-throughput screening applications. Here we report a highly parallel acoustic flow cytometer that uses an acoustic standing wave to focus particles into 16 parallel analysis points across a 2.3 mm wide optical flow cell. A line-focused laser and wide-field collection optics are used to excite and collect the fluorescence emission of these parallel streams onto a high-speed camera for analysis. With this instrument format and fluorescent microsphere standards, we obtain analysis rates of 100K/s and flow rates of 10 mL/min, while maintaining optical performance comparable to that of a commercial flow cytometer. The results with our initial prototype instrument demonstrate that the integration of key parallelizable components, including the line-focused laser, particle focusing using multinode acoustic standing waves, and a spatially arrayed detector, can increase analytical and volumetric throughputs by orders of magnitude in a compact, simple, and cost-effective platform. Such instruments will be of great value to applications in need of high-throughput yet sensitive flow cytometry analysis.
User’s Guide for Biodegradation Reactions in TMVOCBio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, Yoojin; Battistelli, Alfredo
TMVOCBio is an extended version of the TMVOC numerical reservoir simulator, with the capability of simulating multiple biodegradation reactions mediated by different microbial populations or based on different redox reactions, thus involving different electron acceptors. This modeling feature is implemented within the existing TMVOC module in iTOUGH2. TMVOCBio, originally developed by Battistelli (2003; 2004), uses a general modified form of the Monod kinetic rate equation to simulate biodegradation reactions, which effectively simulates the uptake of a substrate while accounting for various limiting factors (i.e., the limitation by substrate, electron acceptor, or nutrients). Two approaches are included: 1) a multiple Monodmore » kinetic rate equation, which assumes all the limiting factors simultaneously affect the substrate uptake rate, and 2) a minimum Monod model, which assumes that the substrate uptake rate is controlled by the most limiting factor among those acting for the specific substrate. As the limiting factors, biomass growth inhibition, toxicity effects, as well as competitive and non-competitive inhibition effects are included. The temperature and moisture dependence of biodegradation reactions is also considered. This report provides mathematical formulations and assumptions used for modeling the biodegradation reactions, and describes additional modeling capabilities. Detailed description of input format for biodegradation reactions is presented along with sample problems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jincheng; Kim, Tong-Ho; Jiao, Wenyuan
Recent work has shown that Bi incorporation increases during molecular beam epitaxy (MBE) when surface processes are kinetically limited through increased growth rate. Herein we explore how the structural and optical properties of GaAs{sub 1−x}Bi{sub x} films are modified when grown under conditions with varying degrees of kinetic limitations realized through growth temperature and growth rate changes. Within the typical window of MBE growth conditions for GaAs{sub 1−x}Bi{sub x}, we compare films with similar (∼3%) compositions grown under conditions of reduced kinetic limitations, i.e., relatively low gallium supersaturation achieved at higher temperatures (∼350 °C) and lower growth rates (∼0.5 μm/h), tomore » those grown farther from equilibrium, specifically, higher supersaturation achieved at lower growth temperatures (∼290 °C) and higher growth rates (∼1.4 μm/h). Both the x-ray diffraction full width at half maximum of the omega-2theta scan and the 300 K photoluminescence intensity increase when samples are grown under less kinetically limited conditions. We interpret these findings in relation to the incorporation of Bi-related microstructural defects that are more readily formed during less kinetically limited growth. These defects lead to enhanced luminescence efficiency due to the spatial localization of carriers.« less
Optical design considerations when imaging the fundus with an adaptive optics correction
NASA Astrophysics Data System (ADS)
Wang, Weiwei; Campbell, Melanie C. W.; Kisilak, Marsha L.; Boyd, Shelley R.
2008-06-01
Adaptive Optics (AO) technology has been used in confocal scanning laser ophthalmoscopes (CSLO) which are analogous to confocal scanning laser microscopes (CSLM) with advantages of real-time imaging, increased image contrast, a resistance to image degradation by scattered light, and improved optical sectioning. With AO, the instrumenteye system can have low enough aberrations for the optical quality to be limited primarily by diffraction. Diffraction-limited, high resolution imaging would be beneficial in the understanding and early detection of eye diseases such as diabetic retinopathy. However, to maintain diffraction-limited imaging, sufficient pixel sampling over the field of view is required, resulting in the need for increased data acquisition rates for larger fields. Imaging over smaller fields may be a disadvantage with clinical subjects because of fixation instability and the need to examine larger areas of the retina. Reduction in field size also reduces the amount of light sampled per pixel, increasing photon noise. For these reasons, we considered an instrument design with a larger field of view. When choosing scanners to be used in an AOCSLO, the ideal frame rate should be above the flicker fusion rate for the human observer and would also allow user control of targets projected onto the retina. In our AOCSLO design, we have studied the tradeoffs between field size, frame rate and factors affecting resolution. We will outline optical approaches to overcome some of these tradeoffs and still allow detection of the earliest changes in the fundus in diabetic retinopathy.
ON THE STAR FORMATION PROPERTIES OF VOID GALAXIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moorman, Crystal M.; Moreno, Jackeline; White, Amanda
2016-11-10
We measure the star formation properties of two large samples of galaxies from the SDSS in large-scale cosmic voids on timescales of 10 and 100 Myr, using H α emission line strengths and GALEX FUV fluxes, respectively. The first sample consists of 109,818 optically selected galaxies. We find that void galaxies in this sample have higher specific star formation rates (SSFRs; star formation rates per unit stellar mass) than similar stellar mass galaxies in denser regions. The second sample is a subset of the optically selected sample containing 8070 galaxies with reliable H i detections from ALFALFA. For the fullmore » H i detected sample, SSFRs do not vary systematically with large-scale environment. However, investigating only the H i detected dwarf galaxies reveals a trend toward higher SSFRs in voids. Furthermore, we estimate the star formation rate per unit H i mass (known as the star formation efficiency; SFE) of a galaxy, as a function of environment. For the overall H i detected population, we notice no environmental dependence. Limiting the sample to dwarf galaxies still does not reveal a statistically significant difference between SFEs in voids versus walls. These results suggest that void environments, on average, provide a nurturing environment for dwarf galaxy evolution allowing for higher specific star formation rates while forming stars with similar efficiencies to those in walls.« less
Virdis, Salvatore; Scarano, Christian; Spanu, Vincenzo; Murittu, Gavino; Spanu, Carlo; Ibba, Ignazio; De Santis, Enrico Pietro Luigi
2014-12-09
In the present work the results of a survey conducted in Sardinia Region on Aflatoxin M 1 (AFM 1 ) contamination in milk of small ruminants from 2005 to 2013 are reported. A total of 517 sheep and 88 goat milk samples from bulk tank, tank trucks and silo tank milk were collected. Analyses were performed by the Regional Farmers Association laboratory using high-performance liquid chromatography following the ISO 14501:1998 standard. None of the sheep milk samples analysed during 2005-2012 showed AFM 1 contamination. In sheep milk samples collected in 2013, 8 out of 172 (4.6%) were contaminated by AFM 1 with a concentration (mean±SD) of 12.59±14.05 ng/L. In one bulk tank milk sample 58.82 ng/L AFM 1 was detected, exceeding the EU limit. In none of goat milk samples analysed from 2010 to 2012 AFM 1 was detected. In 2013, 9 out of 66 goat milk samples (13.6%) showed an AFM 1 concentration of 47.21±19.58 ng/L. Two of these samples exceeded the EU limit, with concentrations of 62.09 and 138.6 ng/L. Higher contamination frequency and concentration rates were detected in bulk tank milk samples collected at farm than in bulk milk truck or silo samples, showing a dilution effect on AFM 1 milk content along small ruminants supply chain. The rate and levels of AFM 1 contamination in sheep and goat milk samples were lower than other countries. However, the small number of milk samples analysed for AFM 1 in Sardinia Region in 2005-2013 give evidence that food business operators check programmes should be improved to ensure an adequate monitoring of AFM 1 contamination in small ruminant dairy chain.
Modified Perfluorocarbon Tracer Method for Measuring Effective Multizone Air Exchange Rates
Shinohara, Naohide; Kataoka, Toshiyuki; Takamine, Koichi; Butsugan, Michio; Nishijima, Hirokazu; Gamo, Masashi
2010-01-01
A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents’ level of exposure, by placing the dosers of tracer gas at locations that resemble indoor emission sources. To measure the 24-h-average effective air exchange rates in future surveys based on this procedure, a low-cost, easy-to-use perfluorocarbon tracer (PFT) doser with a stable dosing rate was developed by using double glass vials, a needle, a polyethylene-sintered filter, and a diffusion tube. Carbon molecular sieve cartridges and carbon disulfide (CS2) were used for passive sampling and extraction of the tracer gas, respectively. Recovery efficiencies, sampling rates, and lower detection limits for 24-h sampling of hexafluorobenzene, octafluorotoluene, and perfluoroallylbenzene were 40% ± 3%, 72% ± 5%, and 84% ± 6%; 10.5 ± 1.1, 14.4 ± 1.4, and 12.2 ± 0.49 mL min−1; and 0.20, 0.17, and 0.26 μg m−3, respectively. PMID:20948928
Modified perfluorocarbon tracer method for measuring effective multizone air exchange rates.
Shinohara, Naohide; Kataoka, Toshiyuki; Takamine, Koichi; Butsugan, Michio; Nishijima, Hirokazu; Gamo, Masashi
2010-09-01
A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents' level of exposure, by placing the dosers of tracer gas at locations that resemble indoor emission sources. To measure the 24-h-average effective air exchange rates in future surveys based on this procedure, a low-cost, easy-to-use perfluorocarbon tracer (PFT) doser with a stable dosing rate was developed by using double glass vials, a needle, a polyethylene-sintered filter, and a diffusion tube. Carbon molecular sieve cartridges and carbon disulfide (CS₂) were used for passive sampling and extraction of the tracer gas, respectively. Recovery efficiencies, sampling rates, and lower detection limits for 24-h sampling of hexafluorobenzene, octafluorotoluene, and perfluoroallylbenzene were 40% ± 3%, 72% ± 5%, and 84% ± 6%; 10.5 ± 1.1, 14.4 ± 1.4, and 12.2 ± 0.49 mL min⁻¹; and 0.20, 0.17, and 0.26 μg m⁻³, respectively.
Biased Brownian dynamics for rate constant calculation.
Zou, G; Skeel, R D; Subramaniam, S
2000-08-01
An enhanced sampling method-biased Brownian dynamics-is developed for the calculation of diffusion-limited biomolecular association reaction rates with high energy or entropy barriers. Biased Brownian dynamics introduces a biasing force in addition to the electrostatic force between the reactants, and it associates a probability weight with each trajectory. A simulation loses weight when movement is along the biasing force and gains weight when movement is against the biasing force. The sampling of trajectories is then biased, but the sampling is unbiased when the trajectory outcomes are multiplied by their weights. With a suitable choice of the biasing force, more reacted trajectories are sampled. As a consequence, the variance of the estimate is reduced. In our test case, biased Brownian dynamics gives a sevenfold improvement in central processing unit (CPU) time with the choice of a simple centripetal biasing force.
Evaluation of the DSM-5 severity ratings for anorexia nervosa in a clinical sample.
Dakanalis, Antonios; Alix Timko, C; Colmegna, Fabrizia; Riva, Giuseppe; Clerici, Massimo
2018-04-01
We examined the validity and utility of the DSM-5 severity ratings for anorexia nervosa (AN) in a clinical (treatment-seeking) sample (N = 273; 95.6% women). Participants classified with mild, moderate, severe, and extreme severity of AN based on their measured body mass index, differed significantly from each other in eating disorder features, putative maintenance factors, and illness-specific functional impairment (medium effect sizes). However, they were statistically indistinguishable in psychiatric-disorder comorbidity and distress, demographics, and age-of-AN onset. The implications of our findings, providing limited support for the DSM-5 severity ratings for AN, and directions for future research are outlined. Copyright © 2018 Elsevier B.V. All rights reserved.
Design and status of the RF-digitizer integrated circuit
NASA Technical Reports Server (NTRS)
Rayhrer, B.; Lam, B.; Young, L. E.; Srinivasan, J. M.; Thomas, J. B.
1991-01-01
An integrated circuit currently under development samples a bandpass-limited signal at a radio frequency in quadrature and then performs a simple sum-and-dump operation in order to filter and lower the rate of the samples. Downconversion to baseband is carried out by the sampling step itself through the aliasing effect of an appropriately selected subharmonic sampling frequency. Two complete RF digitizer circuits with these functions will be implemented with analog and digital elements on one GaAs substrate. An input signal, with a carrier frequency as high as 8 GHz, can be sampled at a rate as high as 600 Msamples/sec for each quadrature component. The initial version of the chip will sign-sample (1-bit) the input RF signal. The chip will contain a synthesizer to generate a sample frequency that is a selectable integer multiple of an input reference frequency. In addition to the usual advantages of compactness and reliability associated with integrated circuits, the single chip will replace several steps required by standard analog downconversion. Furthermore, when a very high initial sample rate is selected, the presampling analog filters can be given very large bandwidths, thereby greatly reducing phase and delay instabilities typically introduced by such filters, as well as phase and delay variation due to Doppler changes.
Be-7 as a tracer for short-term soil surface changes - opportunities and limitations
NASA Astrophysics Data System (ADS)
Baumgart, Philipp
2013-04-01
Within the last 20 years the cosmogenic nuclide Beryllium-7 was successfully established as a suitable tracer element to detect soil surface changes with a high accuracy. Particularly soil erosion rates from single precipitation events are in the focus of different studies due to the short radioactive half-life of the Be-7 isotope. High sorption at topmost soil particles and immobility at given pH-values enable fine-scaled erosion modelling down to 2 mm increments. But some important challenging limitations require particular attention, starting from sampling up to the final data evaluation. E.g. these are the realisation of the fine increment soil collection, the limiting amount of measurable samples per campaign due to the short radioactive half-life and the specific requirements for the detector measurements. Both, the high potential and the challenging limitations are presented as well as future perspectives of that tracer method.
NASA Astrophysics Data System (ADS)
Jantzen, Connie; Slagle, Rick
1997-05-01
The distinction between exposure time and sample rate is often the first point raised in any discussion of high speed imaging. Many high speed events require exposure times considerably shorter than those that can be achieved solely by the sample rate of the camera, where exposure time equals 1/sample rate. Gating, a method of achieving short exposure times in digital cameras, is often difficult to achieve for exposure time requirements shorter than 100 microseconds. This paper discusses the advantages and limitations of using the short duration light pulse of a near infrared laser with high speed digital imaging systems. By closely matching the output wavelength of the pulsed laser to the peak near infrared response of current sensors, high speed image capture can be accomplished at very low (visible) light levels of illumination. By virtue of the short duration light pulse, adjustable to as short as two microseconds, image capture of very high speed events can be achieved at relatively low sample rates of less than 100 pictures per second, without image blur. For our initial investigations, we chose a ballistic subject. The results of early experimentation revealed the limitations of applying traditional ballistic imaging methods when using a pulsed infrared lightsource with a digital imaging system. These early disappointing results clarified the need to further identify the unique system characteristics of the digital imager and pulsed infrared combination. It was also necessary to investigate how the infrared reflectance and transmittance of common materials affects the imaging process. This experimental work yielded a surprising, successful methodology which will prove useful in imaging ballistic and weapons tests, as well as forensics, flow visualizations, spray pattern analyses, and nocturnal animal behavioral studies.
Puzon, Geoffrey J; Lancaster, James A; Wylie, Jason T; Plumb, Iason J
2009-09-01
Rapid detection of pathogenic Naegleria fowler in water distribution networks is critical for water utilities. Current detection methods rely on sampling drinking water followed by culturing and molecular identification of purified strains. This culture-based method takes an extended amount of time (days), detects both nonpathogenic and pathogenic species, and does not account for N. fowleri cells associated with pipe wall biofilms. In this study, a total DNA extraction technique coupled with a real-time PCR method using primers specific for N. fowleri was developed and validated. The method readily detected N. fowleri without preculturing with the lowest detection limit for N. fowleri cells spiked in biofilm being one cell (66% detection rate) and five cells (100% detection rate). For drinking water, the detection limit was five cells (66% detection rate) and 10 cells (100% detection rate). By comparison, culture-based methods were less sensitive for detection of cells spiked into both biofilm (66% detection for <10 cells) and drinking water (0% detection for <10 cells). In mixed cultures of N. fowleri and nonpathogenic Naegleria, the method identified N. fowleri in 100% of all replicates, whereastests with the current consensus primers detected N. fowleri in only 5% of all replicates. Application of the new method to drinking water and pipe wall biofilm samples obtained from a distribution network enabled the detection of N. fowleri in under 6 h, versus 3+ daysforthe culture based method. Further, comparison of the real-time PCR data from the field samples and the standard curves enabled an approximation of N. fowleri cells in the biofilm and drinking water. The use of such a method will further aid water utilities in detecting and managing the persistence of N. fowleri in water distribution networks.
Eypert-Blaison, Céline; Moulut, Jean-Claude; Lecaque, Thierry; Marc, Florian; Kauffer, Edmond
2011-05-01
Sampling the respirable fraction to measure exposure to crystalline silica is most often carried out using cyclones. However, low flow rates (<4 l min(-1)) and continuing improvement in workplace hygiene means less and less material is sampled for analysis, resulting in increased analytical uncertainty. Use of the CIP 10-R sampler, working at a flow rate of 10 l min(-1), is one attempt to solve current analytical difficulties. To check the ability of the analysis of quartz sampled on foams, known amounts of quartz associated with a matrix have been injected into foams. The results obtained show that the proposed protocol, with prior acid attack and ashing of the foams, satisfies the recommendations of EN 482 Standard [CEN. (2006) Workplace atmospheres-general requirements for the performance of procedures for the measurements of chemical agents. Brussels, Belgium: EN 482 Comité Européen de normalization (CEN).], namely an expanded uncertainty of <50% for quartz weights between 0.1 and 0.5 times the 8-h exposure limit value and <30% for quartz weights between 0.5 and 2 times the 8-h exposure limit value, assuming an exposure limit value equal to 0.1 mg m(-3). Results obtained show that the 101 reflection line allows a quartz quantity of the order of 25 μg to be satisfactorily measured, which corresponds to a 10th of the exposure limit value, assuming an exposure limit value of 0.05 mg m(-3). In this case, the 100 and 112 reflection lines with expanded uncertainties of ~50% would also probably lead to satisfactory quantification. Particular recommendations are also proposed for the preparation of calibration curves to improve the method.
Estimation of Glomerular Filtration Rate from Plasma Clearance of 51-Chromium Edetic Acid
Chantler, C.; Barratt, T. M.
1972-01-01
The glomerular filtration rate was estimated by a single compartment analysis of the rate of fall of plasma concentration of 51-chromium edetic acid after a single intravenous injection. This slope clearance consistently overestimated the simultaneously determined standard urinary clearance, but could be used to predict the latter with an accuracy of ±9% (95% confidence limits). The coefficient of variation of replicate estimates of the slope clearance in the same individual was 3·9%; thus two estimates of glomerular filtration rate by this technique which differ by 11% have a 95% probability of reflecting a genuine difference. The method requires an intravenous injection and blood samples at 2 and 4 hours; urine samples are not required. It is simple, safe, and precise, and is applicable to children. PMID:4625784
Strategies and limitations for fluorescence detection of XAFS at high flux beamlines
Heald, Steve M.
2015-02-17
The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 10 13 photons -1. Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detectormore » is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 10 7 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved.« less
Strategies and limitations for fluorescence detection of XAFS at high flux beamlines
Heald, Steve M.
2015-01-01
The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 1013 photons s−1. Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detector is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 107 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved. PMID:25723945
Sun, Ruoyu; Enrico, Maxime; Heimbürger, Lars-Eric; Scott, Clint; Sonke, Jeroen E
2013-08-01
High-precision mercury (Hg) stable isotopic analysis requires relatively large amounts of Hg (>10 ng). Consequently, the extraction of Hg from natural samples with low Hg concentrations (<1-20 ng/g) by wet chemistry is challenging. Combustion-trapping techniques have been shown to be an appropriate alternative. Here, we detail a modified off-line Hg pre-concentration protocol that is based on combustion and trapping. Hg in solid samples is thermally reduced and volatilized in a pure O2 stream using a temperature-programmed combustion furnace. A second furnace, kept at 1,000 °C, decomposes combustion products into H2O, CO2, SO2, etc. The O2 carrier gas, including combustion products and elemental Hg, is then purged into a 40% (v/v) acid-trapping solution. The method was optimized by assessing the variations of Hg pre-concentration efficiency and Hg isotopic compositions as a function of acid ratio, gas flow rate, and temperature ramp rate for two certified reference materials of bituminous coals. Acid ratios of 2HNO3/1HCl (v/v), 25 mL/min O2 flow rate, and a dynamic temperature ramp rate (15 °C/min for 25-150 and 600-900 °C; 2.5 °C/min for 150-600 °C) were found to give optimal results. Hg step-release experiments indicated that significant Hg isotopic fractionation occurred during sample combustion. However, no systematic dependence of Hg isotopic compositions on Hg recovery (81-102%) was observed. The tested 340 samples including coal, coal-associated rocks, fly ash, bottom ash, peat, and black shale sediments with Hg concentrations varying from <5 ng/g to 10 μg/g showed that most Hg recoveries were within the acceptable range of 80-120%. This protocol has the advantages of a short sample processing time (∼3.5 h) and limited transfer of residual sample matrix into the Hg trapping solution. This in turn limits matrix interferences on the Hg reduction efficiency of the cold vapor generator used for Hg isotopic analysis.
L'Engle, Kelly; Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne
2018-01-01
Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit dialing of mobile phones offers promise for future data collection in Ghana and may be suitable for other developing countries.
Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne
2018-01-01
Introduction Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. Materials and methods The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. Results The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. Conclusions The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit dialing of mobile phones offers promise for future data collection in Ghana and may be suitable for other developing countries. PMID:29351349
Elimination Rates of Dioxin Congeners in Former Chlorophenol Workers from Midland, Michigan
Collins, James J.; Bodner, Kenneth M.; Wilken, Michael; Bodnar, Catherine M.
2012-01-01
Background: Exposure reconstructions and risk assessments for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and other dioxins rely on estimates of elimination rates. Limited data are available on elimination rates for congeners other than TCDD. Objectives: We estimated apparent elimination rates using a simple first-order one-compartment model for selected dioxin congeners based on repeated blood sampling in a previously studied population. Methods: Blood samples collected from 56 former chlorophenol workers in 2004–2005 and again in 2010 were analyzed for dioxin congeners. We calculated the apparent elimination half-life in each individual for each dioxin congener and examined factors potentially influencing elimination rates and the impact of estimated ongoing background exposures on rate estimates. Results: Mean concentrations of all dioxin congeners in the sampled participants declined between sampling times. Median apparent half-lives of elimination based on changes in estimated mass in the body were generally consistent with previous estimates and ranged from 6.8 years (1,2,3,7,8,9-hexachlorodibenzo-p-dioxin) to 11.6 years (pentachlorodibenzo-p-dioxin), with a composite half-life of 9.3 years for TCDD toxic equivalents. None of the factors examined, including age, smoking status, body mass index or change in body mass index, initial measured concentration, or chloracne diagnosis, was consistently associated with the estimated elimination rates in this population. Inclusion of plausible estimates of ongoing background exposures decreased apparent half-lives by approximately 10%. Available concentration-dependent toxicokinetic models for TCDD underpredicted observed elimination rates for concentrations < 100 ppt. Conclusions: The estimated elimination rates from this relatively large serial sampling study can inform occupational and environmental exposure and serum evaluations for dioxin compounds. PMID:23063871
[Analysis of heavy metals monitoring results in food in Shaoxing in 2014].
Fan, Wei; Wang, Jing; Wu, Hongmiao; Lian, Lingjun; Du, Sai; Chen, Li
2015-11-01
To investigate heavy metals contamination level in food in Shaoxing, and to provide basis evidence for supervising heavy metals pollution in food and environmental pollution control in Shaoxing. Food samples in 2014 were detected for lead, cadmium, mercury, arsenic, nickel, copper and chromium by national standard methods, and the results were evaluated by GB 2762-2012 Pollutants limits in food. 1384 samples from 10 food categories were collected and tested for lead, cadmium, mercury and arsenic, the over standard rates were 2.0%, 3.0%, 1.5% and 0.22%, respectively, the median were 0.019, 0.0085, 0.0024 and 0.015 mg/kg, respectively; 273 samples were collected and tested for nickel, the detection rate was 48.4%, the median was 0.010 mg/kg; 255 samples were collected and tested for chromium, the detection rate was 14.9%, the median was 0.0050 mg/kg; 486 samples were collected and tested for copper, the detection rate was 94.0%, the median was 1.34 mg/kg. The heavy metals over standard rate of aquatic products, animal internal organs and grain were relatively high, 16.9%, 7.9% and 7.3% cadmium in swimming crabs exceeded standard seriously, the over standard rate was 38.9%. The overall pollution of heavy metals in food are not high in Shaoxing in 2014, but some food (aquatic products, animal internal organs and grain) pollution are relatively outstanding, and have the over standard problems of lead, cadmium, mercury and arsenic.
Compact drilling and sample system
NASA Technical Reports Server (NTRS)
Gillis-Smith, Greg R.; Petercsak, Doug
1998-01-01
The Compact Drilling and Sample System (CDSS) was developed to drill into terrestrial, cometary, and asteroid material in a cryogenic, vacuum environment in order to acquire subsurface samples. Although drills were used by the Apollo astronauts some 20 years ago, this drill is a fraction of the mass and power and operates completely autonomously, able to drill, acquire, transport, dock, and release sample containers in science instruments. The CDSS has incorporated into its control system the ability to gather science data about the material being drilled by measuring drilling rate per force applied and torque. This drill will be able to optimize rotation and thrust in order to achieve the highest drilling rate possible in any given sample. The drill can be commanded to drill at a specified force, so that force imparted on the rover or lander is limited. This paper will discuss the cryo dc brush motors, carbide gears, cryogenic lubrication, quick-release interchangeable sampling drill bits, percussion drilling and the control system developed to achieve autonomous, cryogenic, vacuum, lightweight drilling.
Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C
2017-06-14
A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Arbes, Samuel J; Sever, Michelle; Vaughn, Ben; Mehta, Jigna; Lynch, Jeffrey T; Mitchell, Herman; Hoppin, Jane A; Spencer, Harvey L; Sandler, Dale P; Zeldin, Darryl C
2005-06-01
Studies of indoor allergen exposures are often limited by the cost and logistics of sending technicians to homes to collect dust. In this study we evaluated the feasibility of having subjects collect their own dust samples. The objectives were to compare allergen concentrations between subject- and technician-collected samples and to examine the sample return rate. Using a dust collection device and written instructions provided to them by mail, 102 subjects collected a combined dust sample from a bed and bedroom floor. Later the same day, a technician collected a side-by-side sample. Dust samples were weighed and analyzed for the cat allergen Fel d 1 and the dust mite allergen Der p 1. Fifty additional subjects who were enrolled by telephone were mailed dust collection packages and asked to return a dust sample and questionnaire by mail. A technician did not visit their homes. Correlations between subject- and technician-collected samples were strong for concentrations of Fel d 1 (r = 0.88) and Der p 1 (r = 0.87). With allergen concentrations dichotomized at lower limits of detection and clinically relevant thresholds, agreements between methodologies ranged from 91 to 98%. Although dust weights were correlated (r = 0.48, p < 0.001), subjects collected lighter samples. Among the group of 50 subjects, 46 returned a dust sample and completed questionnaire. The median number of days to receive a sample was 15. With some limitations, subject-collected dust sampling appears to be a valid and practical option for epidemiologic and clinical studies that report allergen concentration as a measure of exposure.
NASA Technical Reports Server (NTRS)
Garland, Jay L.; Roberts, Michael S.; Levine, Lanfang H.; Mills, Aaron L.
2003-01-01
Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells.
NASA Astrophysics Data System (ADS)
Taheriniya, Shabnam; Parhizgar, Sara Sadat; Sari, Amir Hossein
2018-06-01
To study the alumina template pore size distribution as a function of Al thin film grain size distribution, porous alumina templates were prepared by anodizing sputtered aluminum thin films. To control the grain size the aluminum samples were sputtered with the rate of 0.5, 1 and 2 Å/s and the substrate temperature was either 25, 75 or 125 °C. All samples were anodized for 120 s in 1 M sulfuric acid solution kept at 1 °C while a 15 V potential was being applied. The standard deviation value for samples deposited at room temperature but with different rates is roughly 2 nm in both thin film and porous template form but it rises to approximately 4 nm with substrate temperature. Samples with the average grain size of 13, 14, 18.5 and 21 nm respectively produce alumina templates with an average pore size of 8.5, 10, 15 and 16 nm in that order which shows the average grain size limits the average pore diameter in the resulting template. Lateral correlation length and grain boundary effect are other factors that affect the pore formation process and pore size distribution by limiting the initial current density.
Summary of Surface Swipe Sampling for Beryllium on Lead Bricks and Shielding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paik, S Y; Barron, D A
2011-08-03
Approximately 25,000 lbs of lead bricks at Site 300 were assessed by the Site 300 Industrial Hygienis tand Health Physicist for potential contamination of beryllium and radiation for reuse. These lead bricks and shielding had been used as shielding material during explosives tests that included beryllium and depleted uranium. Based on surface swipe sampling that was performed between July 26 and October 11, 2010, specifically for beryllium, the use of a spray encapsulant was found to be an effective means to limit removable surface contamination to levels below the DOE release limit for beryllium, which is 0.2 mcg/100 cm{sup 2}.more » All the surface swipe sampling data for beryllium and a timeline of when the samples were collected (and a brief description) are presented in this report. On December 15, 2010, the lead bricks and shielding were surveyed with an ion chamber and indicated dose rates less than 0.05 mrem per hour on contact. This represents a dose rate consistent with natural background. An additional suevey was performed on February 8, 2011, using a GM survey instrument to estimate total activity on the lead bricks and shielding, confirming safe levels of radioactivity. The vendor is licensed to possess and work with radioactive material.« less
Backhans, Mona C; Mosedale, Sarah; Bruce, Daniel; Whitehead, Margaret; Burström, Bo
2016-08-19
Employment and unemployment are key determinants of health inequalities and should be a priority when discussing policies to reduce such inequalities. Our aim is to investigate how flexicurity policies across European countries impact on the employment chances for people with low education and activity limitations. The longitudinal EU-SILC dataset, pooled 2005-2010, was used to calculate labour market outcomes. The sample consisted of 25 countries and 19,881 individuals. The employment transitions of non-employed people with activity limitations was followed from one year to the next, and the outcomes were rates of return-to work (RTW) among those with low education, and relative equality of RTW between those with low and high education (rate ratio, RR). Data on flexicurity policy and labour market factors were accessed from Eurostat and the OECD. As policy data was only available for OECD countries, the sample was reduced to 21 countries. Fuzzy-set QCA (Qualitative Comparative Analysis) was used to examine how different combinations of the components of flexicurity were linked to the two outcomes. Where high rates of RTW were achieved, high employment rates were always present. In five countries (the Nordic countries and the Netherlands) these factors coexisted with high expenditure on active labour market policies and social services in old age. In three others (The Czech Republic, UK and Estonia) they were combined with low employment protection and low benefit expenditure. For equality in RTW, low unemployment rates were combined with either high benefit expenditure, or low employment protection. We found two routes that lead to high RTW: we characterise these as the high road and the low road. Taking the low road (relaxing employment protection and limiting benefits) may be a tempting option for poorly performing countries. However, without measures to stimulate female employment it may not be enough as high overall employment is so important in enabling people with activity limitations to access the labour market. To achieve equality in RTW, it seems that as long as unemployment is low, either flexibility or security is sufficient.
Raissi, Golam Reza D; Cherati, Afsaneh D Safar; Mansoori, Kourosh D; Razi, Mohammad D
2009-01-01
Objective To determine the relationship between lower extremity alignment and MTSS amongst non-professional athletes Design In a prospective Study, sixty six subjects were evaluated. Bilateral navicular drop test, Q angle, Achilles angle, tibial angle, intermalleolar and intercondylar distance were measured. In addition, runner's height, body mass, history of previous running injury, running experience was recorded. Runners were followed for 17 weeks to determine occurrence of MTSS. Results The overall injury rate for MTSS was 19.7%. The MTSS injury rate in girls (22%) was not significantly different from the rate in boys (14.3%). Most MTSS injuries were induced after 60 hours of exercise, which did not differ between boys and girls. There was a significant difference in right and left navicular drop (ND) in athletes with MTSS. MTSS had no significant correlation with other variables including Quadriceps, Tibia and Achilles angles, intercondylar and intermaleolar lengths and lower extremity lengths. Limitation All measurements performed in this study were uniplanar and static. The small sample size deemed our main limitation. The accurate assessment of participants with previous history of anterior leg pain for MTSS was another limitation. Conclusion Although a significant relationship between navicular drop and MTSS was found in this study; there was not any significant relationship between lower extremity alignment and MTSS in our sample study. PMID:19519909
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovarik, Libor; Stevens, Andrew J.; Liyu, Andrey V.
Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce themore » electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. As a result, the use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO 3, a material that is traditionally difficult to image by TEM/STEM because of dose issues.« less
Kovarik, Libor; Stevens, Andrew J.; Liyu, Andrey V.; ...
2016-10-17
Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce themore » electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. The use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO3, a material that is traditionally difficult to image by TEM/STEM because of dose issues.« less
On Shaft Data Acquisition System (OSDAS)
NASA Technical Reports Server (NTRS)
Pedings, Marc; DeHart, Shawn; Formby, Jason; Naumann, Charles
2012-01-01
On Shaft Data Acquisition System (OSDAS) is a rugged, compact, multiple-channel data acquisition computer system that is designed to record data from instrumentation while operating under extreme rotational centrifugal or gravitational acceleration forces. This system, which was developed for the Heritage Fuel Air Turbine Test (HFATT) program, addresses the problem of recording multiple channels of high-sample-rate data on most any rotating test article by mounting the entire acquisition computer onboard with the turbine test article. With the limited availability of slip ring wires for power and communication, OSDAS utilizes its own resources to provide independent power and amplification for each instrument. Since OSDAS utilizes standard PC technology as well as shared code interfaces with the next-generation, real-time health monitoring system (SPARTAA Scalable Parallel Architecture for Real Time Analysis and Acquisition), this system could be expanded beyond its current capabilities, such as providing advanced health monitoring capabilities for the test article. High-conductor-count slip rings are expensive to purchase and maintain, yet only provide a limited number of conductors for routing instrumentation off the article and to a stationary data acquisition system. In addition to being limited to a small number of instruments, slip rings are prone to wear quickly, and introduce noise and other undesirable characteristics to the signal data. This led to the development of a system capable of recording high-density instrumentation, at high sample rates, on the test article itself, all while under extreme rotational stress. OSDAS is a fully functional PC-based system with 48 channels of 24-bit, high-sample-rate input channels, phase synchronized, with an onboard storage capacity of over 1/2-terabyte of solid-state storage. This recording system takes a novel approach to the problem of recording multiple channels of instrumentation, integrated with the test article itself, packaged in a compact/rugged form factor, consuming limited power, all while rotating at high turbine speeds.
NASA Astrophysics Data System (ADS)
Kuusimäki, Leea; Peltonen, Kimmo; Vainiotalo, Sinikka
A previously introduced method for monitoring environmental tobacco smoke (ETS) was further validated. The method is based on diffusive sampling of a vapour-phase marker, 3-ethenylpyridine (3-EP), with 3 M passive monitors (type 3500). Experiments were done in a dynamic chamber to assess diffusive sampling in comparison with active sampling in charcoal tubes or XAD-4 tubes. The sampling rate for 3-EP collected on the diffusive sampler was 23.1±0.6 mL min -1. The relative standard deviation for parallel samples ( n=6) ranged from 4% to 14% among experiments ( n=9). No marked reverse diffusion of 3-EP was detected nor any significant effect of relative humidity at 20%, 50% or 80%. The diffusive sampling of 3-EP was validated in field measurements in 15 restaurants in comparison with 3-EP and nicotine measurements using active sampling. The 3-EP concentration in restaurants ranged from 0.01 to 9.8 μg m -3, and the uptake rate for 3-EP based on 92 parallel samples was 24.0±0.4 mL min -1. A linear correlation ( r=0.98) was observed between 3-EP and nicotine concentrations, the average ratio of 3-EP to nicotine being 1:8. Active sampling of 3-EP and nicotine in charcoal tubes provided more reliable results than sampling in XAD-4 tubes. All samples were analysed using gas chromatography-mass spectrometry after elution with a 15% solution of pyridine in toluene. For nicotine, the limit of quantification of the charcoal tube method was 4 ng per sample, corresponding to 0.04 μg m -3 for an air sample of 96 L. For 3-EP, the limit of quantification of the diffusive method was 0.5-1.0 ng per sample, corresponding to 0.04-0.09 μg m -3 for 8 h sampling. The diffusive method proved suitable for ETS monitoring, even at low levels of ETS.
Note: Inter-satellite laser range-rate measurement by using digital phase locked loop.
Liang, Yu-Rong; Duan, Hui-Zong; Xiao, Xin-Long; Wei, Bing-Bing; Yeh, Hsien-Chi
2015-01-01
This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future's gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10(-8) Hz/Hz(1/2)@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.
Note: Inter-satellite laser range-rate measurement by using digital phase locked loop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Yu-Rong; Department of Electronics and Information Engineering, Huazhong University of Science and Technology, 1037 Luo Yu Road, Wuhan 430074; Duan, Hui-Zong
2015-01-15
This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future’s gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10{sup −8} Hz/Hz{sup 1/2}@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.
Note: Inter-satellite laser range-rate measurement by using digital phase locked loop
NASA Astrophysics Data System (ADS)
Liang, Yu-Rong; Duan, Hui-Zong; Xiao, Xin-Long; Wei, Bing-Bing; Yeh, Hsien-Chi
2015-01-01
This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future's gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10-8 Hz/Hz1/2@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchida, Y., E-mail: h1312101@mailg.nc-toyama.ac.jp; Takada, E.; Fujisaki, A.
Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was appliedmore » using the EM algorithm and k-means algorithm.« less
40 CFR 63.7733 - What procedures must I use to establish operating limits?
Code of Federal Regulations, 2010 CFR
2010-07-01
... combustion device applied to emissions from a scrap preheater or TEA cold box mold or core making line... and record the scrubbing liquid flow rate during each TEA sampling run in intervals of no more than 15...
The Relationship between the Distribution of Common Carp and Their Environmental DNA in a Small Lake
Eichmiller, Jessica J.; Bajer, Przemyslaw G.; Sorensen, Peter W.
2014-01-01
Although environmental DNA (eDNA) has been used to infer the presence of rare aquatic species, many facets of this technique remain unresolved. In particular, the relationship between eDNA and fish distribution is not known. We examined the relationship between the distribution of fish and their eDNA (detection rate and concentration) in a lake. A quantitative PCR (qPCR) assay for a region within the cytochrome b gene of the common carp (Cyprinus carpio or ‘carp’), an ubiquitous invasive fish, was developed and used to measure eDNA in Lake Staring (MN, USA), in which both the density of carp and their distribution have been closely monitored for several years. Surface water, sub-surface water, and sediment were sampled from 22 locations in the lake, including areas frequently used by carp. In water, areas of high carp use had a higher rate of detection and concentration of eDNA, but there was no effect of fish use on sediment eDNA. The detection rate and concentration of eDNA in surface and sub-surface water were not significantly different (p≥0.5), indicating that eDNA did not accumulate in surface water. The detection rate followed the trend: high-use water > low-use water > sediment. The concentration of eDNA in sediment samples that were above the limit of detection were several orders of magnitude greater than water on a per mass basis, but a poor limit of detection led to low detection rates. The patchy distribution of eDNA in the water of our study lake suggests that the mechanisms that remove eDNA from the water column, such as decay and sedimentation, are rapid. Taken together, these results indicate that effective eDNA sampling methods should be informed by fish distribution, as eDNA concentration was shown to vary dramatically between samples taken less than 100 m apart. PMID:25383965
Eichmiller, Jessica J; Bajer, Przemyslaw G; Sorensen, Peter W
2014-01-01
Although environmental DNA (eDNA) has been used to infer the presence of rare aquatic species, many facets of this technique remain unresolved. In particular, the relationship between eDNA and fish distribution is not known. We examined the relationship between the distribution of fish and their eDNA (detection rate and concentration) in a lake. A quantitative PCR (qPCR) assay for a region within the cytochrome b gene of the common carp (Cyprinus carpio or 'carp'), an ubiquitous invasive fish, was developed and used to measure eDNA in Lake Staring (MN, USA), in which both the density of carp and their distribution have been closely monitored for several years. Surface water, sub-surface water, and sediment were sampled from 22 locations in the lake, including areas frequently used by carp. In water, areas of high carp use had a higher rate of detection and concentration of eDNA, but there was no effect of fish use on sediment eDNA. The detection rate and concentration of eDNA in surface and sub-surface water were not significantly different (p≥0.5), indicating that eDNA did not accumulate in surface water. The detection rate followed the trend: high-use water > low-use water > sediment. The concentration of eDNA in sediment samples that were above the limit of detection were several orders of magnitude greater than water on a per mass basis, but a poor limit of detection led to low detection rates. The patchy distribution of eDNA in the water of our study lake suggests that the mechanisms that remove eDNA from the water column, such as decay and sedimentation, are rapid. Taken together, these results indicate that effective eDNA sampling methods should be informed by fish distribution, as eDNA concentration was shown to vary dramatically between samples taken less than 100 m apart.
ERIC Educational Resources Information Center
DeGrass, Lisa Marie
2009-01-01
Like many childhood disorders, prevalence rates of AD/HD differ significantly across gender, with male-to-female ratios ranging from 2:1 to 9:1 depending on the sample (APA, 1994). Limited research has been conducted thus far in an effort to better understand these differential prevalence rates. However, it has been proposed that the current…
Video-rate volumetric functional imaging of the brain at synaptic resolution.
Lu, Rongwen; Sun, Wenzhi; Liang, Yajie; Kerlin, Aaron; Bierfeld, Jens; Seelig, Johannes D; Wilson, Daniel E; Scholl, Benjamin; Mohar, Boaz; Tanimoto, Masashi; Koyama, Minoru; Fitzpatrick, David; Orger, Michael B; Ji, Na
2017-04-01
Neurons and neural networks often extend hundreds of micrometers in three dimensions. Capturing the calcium transients associated with their activity requires volume imaging methods with subsecond temporal resolution. Such speed is a challenge for conventional two-photon laser-scanning microscopy, because it depends on serial focal scanning in 3D and indicators with limited brightness. Here we present an optical module that is easily integrated into standard two-photon laser-scanning microscopes to generate an axially elongated Bessel focus, which when scanned in 2D turns frame rate into volume rate. We demonstrated the power of this approach in enabling discoveries for neurobiology by imaging the calcium dynamics of volumes of neurons and synapses in fruit flies, zebrafish larvae, mice and ferrets in vivo. Calcium signals in objects as small as dendritic spines could be resolved at video rates, provided that the samples were sparsely labeled to limit overlap in their axially projected images.
Rapid Method of Determining Factors Limiting Bacterial Growth in Soil
Aldén, L.; Demoling, F.; Bååth, E.
2001-01-01
A technique to determine which nutrients limit bacterial growth in soil was developed. The method was based on measuring the thymidine incorporation rate of bacteria after the addition of C, N, and P in different combinations to soil samples. First, the thymidine incorporation method was tested in two different soils: an agricultural soil and a forest humus soil. Carbon (as glucose) was found to be the limiting substance for bacterial growth in both of these soils. The effect of adding different amounts of nutrients was studied, and tests were performed to determine whether the additions affected the soil pH and subsequent bacterial activity. The incubation time required to detect bacterial growth after adding substrate to the soil was also evaluated. Second, the method was used in experiments in which three different size fractions of straw (1 to 2, 0.25 to 1, and <0.25 mm) were mixed into the agricultural soil in order to induce N limitation for bacterial growth. When the straw fraction was small enough (<0.25 mm), N became the limiting nutrient for bacterial growth after about 3 weeks. After the addition of the larger straw fractions (1 to 2 and 0.25 to 1 mm), the soil bacteria were C limited throughout the incubation period (10 weeks), although an increase in the thymidine incorporation rate after the addition of C and N together compared with adding them separately was seen in the sample containing the size fraction from 0.25 to 1 mm. Third, soils from high-pH, limestone-rich areas were examined. P limitation was observed in one of these soils, while tendencies toward P limitation were seen in some of the other soils. PMID:11282640
Electrochemical Determination of Metronidazole in Tablet Samples Using Carbon Paste Electrode
Nikodimos, Yosef
2016-01-01
Cyclic voltammetric investigation of metronidazole at carbon paste electrode revealed an irreversible reduction peak centered at about −0.4 V. Observed peak potential shift with pH in the range 2.0 to 8.5 indicated the involvement of protons during the reduction of metronidazole, whereas the peak potential shift with scan rate in the range 10–250 mV/s confirmed the irreversibility of the reduction reaction. A better correlation coefficient for the dependence of peak current on the scan rate than on the square root of scan rate indicated an adsorption controlled kinetics. Under the optimized method and solution parameters, an excellent linearity between the reductive peak current and the concentration of metronidazole was observed in the concentration range 1.0 × 10−6 to 5.0 × 10−4 M with a correlation coefficient, method detection limit (based on s = 3σ), and limit of quantification of 0.999, 2.97 × 10−7 M and 9.91 × 10−7 M, respectively. Good recovery results for spiked metronidazole in tablet samples and selective determination of metronidazole in tablet formulations in the presence of selected potential interferents such as rabeprazole, omeprazole, and tinidazole confirmed the potential applicability of the developed method for the determination of metronidazole in real samples like pharmaceutical tablets. PMID:27119041
Electron Microprobe Measurements of Nitrogen in SiC
NASA Astrophysics Data System (ADS)
Ross, K.
2007-12-01
Methods have been developed for the measurement of low abundances of nitrogen in SiC films. These techniques were developed for measurements of synthetic thin-film samples prepared by materials scientists but the technique can also be applied to natural SiC grains in meteorites. One problem associated with measuring nitrogen at low abundance levels is the low count rates due to strong absorption of the nitrogen signal in the matrix material. In thin film samples, (SiC deposited on elemental Si) it is preferable to limit x-ray production and emission to the overlayer. This eliminates the need for data reduction using thin-film methods. Thin film data reduction is inevitably less accurate than bulk material data reduction methods. In order to limit x-ray emission to the film layer, data has been collected at 5 kV and 3.5 kV accelerating voltage (depending on film thickness estimates provided by scientists who prepared these samples). These low beam energies also promote production of x-rays in the shallow region of the samples, and this minimizes strong absorption, leading to more abundant nitrogen x-ray detection, which improves counting statistics and overall precision. The CASINO monte carlo modeling program was used to model electron penetration and x-ray production as a function of beam energy and depth in the sample in order to ensure that the excited volume is limited to the film. The beam was set to 200 nA beam current. This high beam current also improves counting statistics by providing more abundant count rates. One drawback of these beam conditions is the limited spatial resolution provided. In our Cameca probe, a 5 kV, 200 nA beam is approximately 10 microns in diameter. SiC samples and standard were not carbon coated (they are conducting). AlN was used as the nitrogen standard. These films contained 0.3 to 0.7 wt. per cent nitrogen, with analytical uncertainties in the range of 10-20 per cent relative errors. The Si:C ratios were very near 1:1 indicating that little if any Si signal originated in the substrate of the film.
Harris, Liam W.; Davies, T. Jonathan
2016-01-01
Explaining the uneven distribution of species richness across the branches of the tree of life has been a major challenge for evolutionary biologists. Advances in phylogenetic reconstruction, allowing the generation of large, well-sampled, phylogenetic trees have provided an opportunity to contrast competing hypotheses. Here, we present a new time-calibrated phylogeny of seed plant families using Bayesian methods and 26 fossil calibrations. While there are various published phylogenetic trees for plants which have a greater density of species sampling, we are still a long way from generating a complete phylogeny for all ~300,000+ plants. Our phylogeny samples all seed plant families and is a useful tool for comparative analyses. We use this new phylogenetic hypothesis to contrast two alternative explanations for differences in species richness among higher taxa: time for speciation versus ecological limits. We calculated net diversification rate for each clade in the phylogeny and assessed the relationship between clade age and species richness. We then fit models of speciation and extinction to individual branches in the tree to identify major rate-shifts. Our data suggest that the majority of lineages are diversifying very slowly while a few lineages, distributed throughout the tree, are diversifying rapidly. Diversification is unrelated to clade age, no matter the age range of the clades being examined, contrary to both the assumption of an unbounded lineage increase through time, and the paradigm of fixed ecological limits. These findings are consistent with the idea that ecology plays a role in diversification, but rather than imposing a fixed limit, it may have variable effects on per lineage diversification rates through time. PMID:27706173
Abril, José-María; García-Tenorio, Rafael; Manjón, Guillermo
2009-05-30
Phosphogypsum (PG) is a by-product of the phosphate fertilizer industries that contains relatively high concentrations of uranium series radionuclides. The US-EPA regulates the agriculture use of PG, attending to its (226)Ra content and to the (222)Rn exhalation rate from inactive stacks. Measurements of (222)Rn exhalation rates in PG stacks typically show a large and still poorly understood spatial and temporal variability, and the published data are scarce. This work studies an inactive PG stack in SW Spain of about 0.5 km(2) from where PG can be extracted for agriculture uses, and an agriculture soil 75 km apart, being representative of the farms to be amended with PG. Activity concentrations of (226)Ra, (238)U and (210)Po have been measured in 30 PG samples (0-90 cm horizon) allowing for the construction of maps with spatial distributions in the PG stack and for the characterization of the associated PG inputs to agriculture soils. Averaged (226)Ra concentrations for the stack were 730+/-60 Bq kg(-1) (d.w.), over the US-EPA limit of 370 Bq kg(-1). (222)Rn exhalation rate has been measured by the charcoal canister method in 49 sampling points with 3 canisters per sampling point. Values in PG stack were under the US-EPA limit of 2600 Bq m(-2)h(-1), but they were one order of magnitude higher than those found in the agriculture soil. Variability in radon emissions has been studied at different spatial scales. Radon exhalation rates were correlated with (226)Ra concentrations and daily potential evapotranspiration (ETo). They increased with ETo in agriculture soils, but showed an opposite behaviour in the PG stack.
Xu, Stanley; Clarke, Christina L; Newcomer, Sophia R; Daley, Matthew F; Glanz, Jason M
2018-05-16
Vaccine safety studies are often electronic health record (EHR)-based observational studies. These studies often face significant methodological challenges, including confounding and misclassification of adverse event. Vaccine safety researchers use self-controlled case series (SCCS) study design to handle confounding effect and employ medical chart review to ascertain cases that are identified using EHR data. However, for common adverse events, limited resources often make it impossible to adjudicate all adverse events observed in electronic data. In this paper, we considered four approaches for analyzing SCCS data with confirmation rates estimated from an internal validation sample: (1) observed cases, (2) confirmed cases only, (3) known confirmation rate, and (4) multiple imputation (MI). We conducted a simulation study to evaluate these four approaches using type I error rates, percent bias, and empirical power. Our simulation results suggest that when misclassification of adverse events is present, approaches such as observed cases, confirmed case only, and known confirmation rate may inflate the type I error, yield biased point estimates, and affect statistical power. The multiple imputation approach considers the uncertainty of estimated confirmation rates from an internal validation sample, yields a proper type I error rate, largely unbiased point estimate, proper variance estimate, and statistical power. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rapid method for measuring rotenone in water at piscicidal concentrations
Dawson, V.K.; Harman, P.D.; Schultz, D.P.; Allen, J.L.
1983-01-01
A high-performance liquid chromatography (HPLC) procedure that is rapid, specific, and sensitive (limit of detection <0.005 mg/liter) was developed for monitoring application and degradation rates of rotenone. For analysis, a water sample is buffered to pH 5 and injected through a Sep Pak(R) C18 disposable cartridge. The cartridge adsorbs and retains the rotenone which then can be eluted quantitatively from the cartridge with a small volume of methanol. This step effectively concentrates the sample and provides sample cleanup. The methanol extract is analyzed directly by HPLC on an MCH 10 reverse-phase column; methanol: water (75:25, volume : volume) is the mobile phase and flow rate is 1.5 ml/minute. The rotenone is detected by ultraviolet spectrophotometry at a wavelength of 295 nm.
ERIC Educational Resources Information Center
Baenen, Nancy
2011-01-01
The longitudinal study of the 2005-06 preschool in Wake County Public School System (WCPSS) found short-term gains during the preschool year, but limited impact by kindergarten and no average impact by the end of 3rd grade on achievement, retention rates, special education placements, or attendance. Small sample sizes limit conclusions that can be…
Turiano, Nicholas A; Pitzer, Lindsay; Armour, Cherie; Karlamangla, Arun; Ryff, Carol D; Mroczek, Daniel K
2012-01-01
Personality traits predict numerous health outcomes, but previous studies have rarely used personality change to predict health. The current investigation utilized a large national sample of 3,990 participants from the Midlife in the U.S. study (MIDUS) to examine if both personality trait level and personality change longitudinally predict 3 different health outcomes (i.e., self-rated physical health, self-reported blood pressure, and number of days limited at work or home due to physical health reasons) over a 10-year span. Each of the Big Five traits, except openness, predicted self-rated health. Change in agreeableness, conscientiousness, and extraversion also predicted self-rated health. Trait levels of conscientiousness and neuroticism level predicted self-reported blood pressure. All trait levels except agreeableness predicted number of work days limited. Only change in conscientiousness predicted the number of work days limited. Findings demonstrate that a full understanding of the link between personality and health requires consideration of trait change as well as trait level.
A Post-Processing Receiver for the Lunar Laser Communications Demonstration Project
NASA Technical Reports Server (NTRS)
Srinivasan, Meera; Birnbaum, Kevin; Cheng, Michael; Quirk, Kevin
2013-01-01
The Lunar Laser Communications Demonstration Project undertaken by MIT Lincoln Laboratory and NASA's Goddard Space Flight Center will demonstrate high-rate laser communications from lunar orbit to the Earth. NASA's Jet Propulsion Laboratory is developing a backup ground station supporting a data rate of 39 Mbps that is based on a non-real-time software post-processing receiver architecture. This approach entails processing sample-rate-limited data without feedback in the presence high uncertainty in downlink clock characteristics under low signal flux conditions. In this paper we present a receiver concept that addresses these challenges with descriptions of the photodetector assembly, sample acquisition and recording platform, and signal processing approach. End-to-end coded simulation and laboratory data analysis results are presented that validate the receiver conceptual design.
The Oxidation Rate of SiC in High Pressure Water Vapor Environments
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.; Robinson, R. Craig
1999-01-01
CVD SiC and sintered alpha-SiC samples were exposed at 1316 C in a high pressure burner rig at total pressures of 5.7, 15, and 25 atm for times up to 100h. Variations in sample emittance for the first nine hours of exposure were used to determine the thickness of the silica scale as a function of time. After accounting for volatility of silica in water vapor, the parabolic rate constants for Sic in water vapor pressures of 0.7, 1.8 and 3.1 atm were determined. The dependence of the parabolic rate constant on the water vapor pressure yielded a power law exponent of one. Silica growth on Sic is therefore limited by transport of molecular water vapor through the silica scale.
Pan-Planets: Searching for hot Jupiters around cool dwarfs
NASA Astrophysics Data System (ADS)
Obermeier, C.; Koppenhoefer, J.; Saglia, R. P.; Henning, Th.; Bender, R.; Kodric, M.; Deacon, N.; Riffeser, A.; Burgett, W.; Chambers, K. C.; Draper, P. W.; Flewelling, H.; Hodapp, K. W.; Kaiser, N.; Kudritzki, R.-P.; Magnier, E. A.; Metcalfe, N.; Price, P. A.; Sweeney, W.; Wainscoat, R. J.; Waters, C.
2016-03-01
The Pan-Planets survey observed an area of 42 sq deg. in the galactic disk for about 165 h. The main scientific goal of the project is the detection of transiting planets around M dwarfs. We establish an efficient procedure for determining the stellar parameters Teff and log g of all sources using a method based on SED fitting, utilizing a three-dimensional dust map and proper motion information. In this way we identify more than 60 000 M dwarfs, which is by far the largest sample of low-mass stars observed in a transit survey to date. We present several planet candidates around M dwarfs and hotter stars that are currently being followed up. Using Monte Carlo simulations we calculate the detection efficiency of the Pan-Planets survey for different stellar and planetary populations. We expect to find 3.0+3.3-1.6 hot Jupiters around F, G, and K dwarfs with periods lower than 10 days based on the planet occurrence rates derived in previous surveys. For M dwarfs, the percentage of stars with a hot Jupiter is under debate. Theoretical models expect a lower occurrence rate than for larger main sequence stars. However, radial velocity surveys find upper limits of about 1% due to their small sample, while the Kepler survey finds a occurrence rate that we estimate to be at least 0.17b(+0.67-0.04) %, making it even higher than the determined fraction from OGLE-III for F, G and K stellar types, 0.14 (+0.15-0.076) %. With the large sample size of Pan-Planets, we are able to determine an occurrence rate of 0.11 (+0.37-0.02) % in case one of our candidates turns out to be a real detection. If, however, none of our candidates turn out to be true planets, we are able to put an upper limit of 0.34% with a 95% confidence on the hot Jupiter occurrence rate of M dwarfs. This limit is a significant improvement over previous estimates where the lowest limit published so far is 1.1% found in the WFCAM Transit Survey. Therefore we cannot yet confirm the theoretical prediction of a lower occurrence rate for cool stars. Based on observations obtained with the Hobby-Eberly Telescope, which is a joint project of the University of Texas at Austin, the Pennsylvania State University, Stanford University, Ludwig-Maximilians-Universität München, and Georg-August-Universität Göttingen.
Soorkia, Satchin; Liu, Chen-Lin; Savee, John D; Ferrell, Sarah J; Leone, Stephen R; Wilson, Kevin R
2011-12-01
A new pulsed Laval nozzle apparatus with vacuum ultraviolet (VUV) synchrotron photoionization quadrupole mass spectrometry is constructed to study low-temperature radical-neutral chemical reactions of importance for modeling the atmosphere of Titan and the outer planets. A design for the sampling geometry of a pulsed Laval nozzle expansion has been developed that operates successfully for the determination of rate coefficients by time-resolved mass spectrometry. The new concept employs airfoil sampling of the collimated expansion with excellent sampling throughput. Time-resolved profiles of the high Mach number gas flow obtained by photoionization signals show that perturbation of the collimated expansion by the airfoil is negligible. The reaction of C(2)H with C(2)H(2) is studied at 70 K as a proof-of-principle result for both low-temperature rate coefficient measurements and product identification based on the photoionization spectrum of the reaction product versus VUV photon energy. This approach can be used to provide new insights into reaction mechanisms occurring at kinetic rates close to the collision-determined limit.
Sahin, Latife; Hafızoğlu, Nurgül; Çetinkaya, Hakan; Manisa, Kaan; Bozkurt, Engin; Biçer, Ahmet
2017-05-01
The analysis of natural radioactivity from 238 U, 232 Th and 40 K in 357 soil samples collected from the province of Kütahya was carried out using a NaI(Tl) gamma-ray spectroscopy system at the Nuclear Physics Research Laboratory, Dumlupınar University, Kütahya, Turkey. The specific activities of 238 U, 232 Th and 40 K in the soil samples were evaluated. From the activity concentrations of 238 U, 232 Th and 40 K, the total absorbed outdoor gamma-ray dose rates and the corresponding annual effective dose rates were determined. The corresponding values of the external and internal hazard indices of all the soil samples were also calculated. The external gamma-ray dose rate at 1 m above the ground was directly measured at each collected soil sample location. The results obtained in this study were compared within the limits of values obtained in other cities of Turkey, those in other countries. Radiological maps of Kütahya Province were constructed from the results of this study.
Kazantzis, Nikolaos; Dattilio, Frank M
2010-07-01
A random sample of 827 psychologists were surveyed to assess their definitions of homework, use of homework tasks, and perceived importance of homework. Theoretical orientation distinguished practitioners' responses. Cognitive-behavioral therapists defined homework as being closer to empirically supported therapy, whereas psychodynamic therapists rated homework as less characteristic of a process that embraces client responsibility and adaptive skills. Cognitive-behavior therapists did not limit their choices to activity-based tasks, and psychodynamic therapists reported using behavioral tasks "sometimes." Monitoring dreams and conscious thought were also used among the entire sample surveyed. Psychodynamic therapists rated homework as "somewhat" or "moderately" important, whereas cognitive-behavior therapists more often rated homework as "very important." Data suggest some homework may be common to different psychotherapeutic approaches. Findings are discussed in the context of recent theoretical work on homework in psychotherapy and recommendations for future research.
NASA Astrophysics Data System (ADS)
Tivey, M.; Farr, N.; Ware, J.; Pontbriand, C.
2011-12-01
A CORK (Circulation Obviation Retrofit Kit) borehole represents all of the basic components required for a seafloor observatory: a stable environment for long-term continuous measurements of earth and ocean phenomena, access to a unique environment below the seafloor under controlled conditions (e.g. hydrologically sealed), and a standard interface for communication. Typically, however, due to power constraints and a limited frequency of data download opportunities, data sampling has been limited to rates on the order of several minutes. For full seismic wave sampling, at least 1 Hz or better is required. While some CORK systems are now being connected to an underwater cable to provide continuous power and real-time data (cf. Neptune network in the Northeast Pacific), there will be locations where cabled observatories are not viable. Another mode of communication is required to enable both high data rate communication and access for data download via more conventional vessels and not limited to those with ROV or submersibles. We here report on technology to enable high data rate download and transfer of data and information using underwater optical communications, which can be accomplished from a surface vessel of opportunity or, in the future, by autonomous underwater vehicle. In 2010, we successfully deployed and tested an underwater optical communication system that provides high data rate communications over a range of 100 meters from a deep sea CORK borehole observatory located in the northeast Pacific at IODP Hole 857D. The CORK is instrumented with a thermistor string and pressure sensors that record downhole formation pressures and temperatures within oceanic basement and is pressure sealed from the overlying water column. The seafloor Optical Telemetry System (OTS) was plugged into the CORK's existing underwater matable connector to provide an optical and acoustic communication interface and additional data storage and battery power for the CORK to sample at 1 Hz data-rate, an increase over the normal 15 sec data sample rate. A CTD-mounted OTS lowered by wire from a surface ship established an optical communication link at 100 meters range at rates of 1, 5 and 10 Mbps with no bit errors. This mode of communication demonstrates the effectiveness of using a ship-based system to interrogate the system remotely. The OTS was designed to be installed at the seafloor CORK for a year. In 2011, we will revisit the CORK and OTS using the ROV Jason to test the system, download the data collected during this period and to refurbish the batteries for a further year-long deployment period. We will report on the results of those tests at the meeting. As the need to observe oceanic and earth phenomenon over periods not limited to weather windows or cruise schedules increases, the borehole observatory will provide an important venue for gaining access to such timescales. High data-rate underwater communications will be required to make full use of such observatory infrastructure. The use of free water optical communication methods provides a logical way to accomplish these goals in the future.
Tsujino, Soichiro; Tomizaki, Takashi
2016-05-06
Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.
Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature
NASA Astrophysics Data System (ADS)
Tsujino, Soichiro; Tomizaki, Takashi
2016-05-01
Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.
Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature
Tsujino, Soichiro; Tomizaki, Takashi
2016-01-01
Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography. PMID:27150272
NASA Technical Reports Server (NTRS)
Corbett, Lee B.; Bierman, Paul R.; Graly, Joseph A.; Neumann, Thomas A.; Rood, Dylan H.
2013-01-01
High-latitude landscape evolution processes have the potential to preserve old, relict surfaces through burial by cold-based, nonerosive glacial ice. To investigate landscape history and age in the high Arctic, we analyzed in situ cosmogenic Be(sup 10) and Al (sup 26) in 33 rocks from Upernavik, northwest Greenland. We sampled adjacent bedrock-boulder pairs along a 100 km transect at elevations up to 1000 m above sea level. Bedrock samples gave significantly older apparent exposure ages than corresponding boulder samples, and minimum limiting ages increased with elevation. Two-isotope calculations Al(sup26)/B(sup 10) on 20 of the 33 samples yielded minimum limiting exposure durations up to 112 k.y., minimum limiting burial durations up to 900 k.y., and minimum limiting total histories up to 990 k.y. The prevalence of BE(sup 10) and Al(sup 26) inherited from previous periods of exposure, especially in bedrock samples at high elevation, indicates that these areas record long and complex surface exposure histories, including significant periods of burial with little subglacial erosion. The long total histories suggest that these high elevation surfaces were largely preserved beneath cold-based, nonerosive ice or snowfields for at least the latter half of the Quaternary. Because of high concentrations of inherited nuclides, only the six youngest boulder samples appear to record the timing of ice retreat. These six samples suggest deglaciation of the Upernavik coast at 11.3 +/- 0.5 ka (average +/- 1 standard deviation). There is no difference in deglaciation age along the 100 km sample transect, indicating that the ice-marginal position retreated rapidly at rates of approx.120 m yr(sup-1).
Strong Spatial Influence on Colonization Rates in a Pioneer Zooplankton Metacommunity
Frisch, Dagmar; Cottenie, Karl; Badosa, Anna; Green, Andy J.
2012-01-01
The magnitude of community-wide dispersal is central to metacommunity models, yet dispersal is notoriously difficult to quantify in passive and cryptic dispersers such as many freshwater invertebrates. By overcoming the problem of quantifying dispersal rates, colonization rates into new habitats can provide a useful estimate of the magnitude of effective dispersal. Here we study the influence of spatial and local processes on colonization rates into new ponds that indicate differential dispersal limitation of major zooplankton taxa, with important implications for metacommunity dynamics. We identify regional and local factors that affect zooplankton colonization rates and spatial patterns in a large-scale experimental system. Our study differs from others in the unique setup of the experimental pond area by which we were able to test spatial and environmental variables at a large spatial scale. We quantified colonization rates separately for the Copepoda, Cladocera and Rotifera from samples collected over a period of 21 months in 48 newly constructed temporary ponds of 0.18–2.95 ha distributed in a restored wetland area of 2,700 ha in Doñana National Park, Southern Spain. Species richness upon initial sampling of new ponds was about one third of that in reference ponds, although the rate of detection of new species from thereon were not significantly different, probably owing to high turnover in the dynamic, temporary reference ponds. Environmental heterogeneity had no detectable effect on colonization rates in new ponds. In contrast, connectivity, space (based on latitude and longitude) and surface area were key determinants of colonization rates for copepods and cladocerans. This suggests dispersal limitation in cladocerans and copepods, but not in rotifers, possibly due to differences in propagule size and abundance. PMID:22792241
Strong spatial influence on colonization rates in a pioneer zooplankton metacommunity.
Frisch, Dagmar; Cottenie, Karl; Badosa, Anna; Green, Andy J
2012-01-01
The magnitude of community-wide dispersal is central to metacommunity models, yet dispersal is notoriously difficult to quantify in passive and cryptic dispersers such as many freshwater invertebrates. By overcoming the problem of quantifying dispersal rates, colonization rates into new habitats can provide a useful estimate of the magnitude of effective dispersal. Here we study the influence of spatial and local processes on colonization rates into new ponds that indicate differential dispersal limitation of major zooplankton taxa, with important implications for metacommunity dynamics. We identify regional and local factors that affect zooplankton colonization rates and spatial patterns in a large-scale experimental system. Our study differs from others in the unique setup of the experimental pond area by which we were able to test spatial and environmental variables at a large spatial scale. We quantified colonization rates separately for the Copepoda, Cladocera and Rotifera from samples collected over a period of 21 months in 48 newly constructed temporary ponds of 0.18-2.95 ha distributed in a restored wetland area of 2,700 ha in Doñana National Park, Southern Spain. Species richness upon initial sampling of new ponds was about one third of that in reference ponds, although the rate of detection of new species from thereon were not significantly different, probably owing to high turnover in the dynamic, temporary reference ponds. Environmental heterogeneity had no detectable effect on colonization rates in new ponds. In contrast, connectivity, space (based on latitude and longitude) and surface area were key determinants of colonization rates for copepods and cladocerans. This suggests dispersal limitation in cladocerans and copepods, but not in rotifers, possibly due to differences in propagule size and abundance.
Passive Synthetic Aperture Radar Imaging Using Commercial OFDM Communication Networks
2012-09-13
baseband sampling is key to ensure proper correlation with a reference signal. The DFT represents the sam- pled spectrum of a periodic discrete sequence...convenient to sample the baseband time domain segments at a rate of Ts/N . In this way, the segments are easily correlated to the elemental form of the...phase history solution of Gp ,l[k ′ n] = Sp,l,n ϕp,l,ndp,l,nN2 , dp,l,n 6= 0. (5.5.13) The segment need not be limited to N samples . For segments of length
Search for Bs0 oscillations using inclusive lepton events
NASA Astrophysics Data System (ADS)
ALEPH Collaboration; Barate, R.; et al.
1999-03-01
A search for Bs0 oscillations is performed using a sample of semileptonic b-hadron decays collected by the ALEPH experiment during 1991-95. Compared to previous inclusive lepton analyses, the proper time resolution and b-flavour mistag rate are significantly improved. Additional sensitivity to Bs0 mixing is obtained by identifying subsamples of events having a Bs0 purity which is higher than the average for the whole data sample. Unbinned maximum likelihood amplitude fits are performed to derive a lower limit of Δ m s > 9.5 ps-1 at the 95% confidence limit (95% CL). Combining with the ALEPH Ds--based analyses yields Δ m s > 9.6 ps-1 at 95% CL.
An Analysis of Several Dimensions of Patient Safety in Ambulatory-Care Facilities
2008-04-09
States were surveyed for a total sample size (N) of 213 and an overall response rate of 65%. Specialty areas, ambulatory-surgical staff, administrative...questions regarding safety. This research was limited in that it sampled only Air Force primary care staff and should certainly be replicated...What is its essence? The Greeks answered the question about substance in the sixth century with descriptions of the four fundamental elements : earth
Practical quantum random number generator based on measuring the shot noise of vacuum states
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen Yong; Zou Hongxin; Tian Liang
2010-06-15
The shot noise of vacuum states is a kind of quantum noise and is totally random. In this paper a nondeterministic random number generation scheme based on measuring the shot noise of vacuum states is presented and experimentally demonstrated. We use a homodyne detector to measure the shot noise of vacuum states. Considering that the frequency bandwidth of our detector is limited, we derive the optimal sampling rate so that sampling points have the least correlation with each other. We also choose a method to extract random numbers from sampling values, and prove that the influence of classical noise canmore » be avoided with this method so that the detector does not have to be shot-noise limited. The random numbers generated with this scheme have passed ent and diehard tests.« less
Estimating the Limits of Infiltration in the Urban Appalachian Plateau
NASA Astrophysics Data System (ADS)
Lavin, S. M.; Bain, D.; Hopkins, K. G.; Pfeil-McCullough, E. K.; Copeland, E.
2014-12-01
Green infrastructure in urbanized areas commonly uses infiltration systems, such as rain gardens, swales and trenches, to convey surface runoff from impervious surfaces into surrounding soils. However, precipitation inputs can exceed soil infiltration rates, creating a limit to infiltration-based storm water management, particularly in urban areas covered by impervious surfaces. Given the limited availability and varied quality of soil infiltration rate data, we synthesized information from national databases, available field test data, and applicable literature to characterize soil infiltration rate distributions, focusing on Allegheny County, Pennsylvania as a case study. A range of impervious cover conditions was defined by sampling available GIS data (e.g., LiDAR and street edge lines) with analysis windows placed randomly across urbanization gradients. Changes in effective precipitation caused by impervious cover were calculated across these gradients and compared to infiltration rate distributions to identify thresholds in impervious coverage where these limits are exceeded. Many studies have demonstrated the effects of urbanization on infiltration, but the identification of these thresholds will clarify interactions between impervious cover and soil infiltration. These methods can help identify sections of urban areas that require augmentation of infiltration-based systems with additional infrastructural strategies, especially as green infrastructure moves beyond low impact development towards more frequent application during infilling of existing urban systems.
Charge displacement in bacteriorhodopsin during the forward and reverse bR-K phototransition.
Groma, G I; Hebling, J; Ludwig, C; Kuhl, J
1995-01-01
Dried oriented purple membrane samples of Halobacterium salinarium were excited by 150 fs laser pulses of 620 nm with a 7 kHz repetition rate. An unusual complex picosecond electric response signal consisting of a positive and a negative peak was detected by a sampling oscilloscope. The ratio of the two peaks was changed by 1) reducing the repetition rate, 2) varying the intensity of the excitation beam, and 3) applying background illumination by light of 647 nm or 511 nm. All of these features can be explained by the simultaneous excitation of the bacteriorhodopsin ground form and the K intermediate. The latter was populated by the (quasi)continuous excitation attributable to its prolonged lifetime in a dehydrated state. Least-square analysis resulted in a 5 ps upper and 2.5 ps lower limit for the time constant of the charge displacement process, corresponding to the forward reaction. That is in good agreement with the formation time of K. The charge separation driven by the reverse phototransition was faster, having a time constant of a 3.5 ps upper limit. The difference in the rates indicates the existence of different routes for the forward and the reverse photoreactions. PMID:8580349
Cacho, J I; Nicolás, J; Viñas, P; Campillo, N; Hernández-Córdoba, M
2016-12-02
A solventless analytical method is proposed for analyzing the compounds responsible for cork taint in cork stoppers. Direct sample introduction (DSI) is evaluated as a sample introduction system for the gas chromatography-mass spectrometry (GC-MS) determination of four haloanisoles (HAs) in cork samples. Several parameters affecting the DSI step, including desorption temperature and time, gas flow rate and other focusing parameters, were optimized using univariate and multivariate approaches. The proposed method shows high sensitivity and minimises sample handling, with detection limits of 1.6-2.6ngg -1 , depending on the compound. The suitability of the optimized procedure as a screening method was evaluated by obtaining decision limits (CCα) and detection capabilities (CCβ) for each analyte, which were found to be in 6.9-11.8 and 8.7-14.8ngg -1 , respectively, depending on the compound. Twenty-four cork samples were analysed, and 2,4,6-trichloroanisole was found in four of them at levels between 12.6 and 53ngg -1 . Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Cartwright, Ian; Cendón, Dioni; Currell, Matthew; Meredith, Karina
2017-12-01
Documenting the location and magnitude of groundwater recharge is critical for understanding groundwater flow systems. Radioactive tracers, notably 14C, 3H, 36Cl, and the noble gases, together with other tracers whose concentrations vary over time, such as the chlorofluorocarbons or sulfur hexafluoride, are commonly used to estimate recharge rates. This review discusses some of the advantages and problems of using these tracers to estimate recharge rates. The suite of tracers allows recharge to be estimated over timescales ranging from a few years to several hundred thousand years, which allows both the long-term and modern behaviour of groundwater systems to be documented. All tracers record mean residence times and mean recharge rates rather than a specific age and date of recharge. The timescale over which recharge rates are averaged increases with the mean residence time. This is an advantage in providing representative recharge rates but presents a problem in comparing recharge rates derived from these tracers with those from other techniques, such as water table fluctuations or lysimeters. In addition to issues relating to the sampling and interpretation of specific tracers, macroscopic dispersion and mixing in groundwater flow systems limit how precisely groundwater residence times and recharge rates may be estimated. Additionally, many recharge studies have utilised existing infrastructure that may not be ideal for this purpose (e.g., wells with long screens that sample groundwater several kilometres from the recharge area). Ideal recharge studies would collect sufficient information to optimise the use of specific tracers and minimise the problems of mixing and dispersion.
Sert, Şenol
2013-07-01
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal standard for the internal standardization method. The robust conditions were evaluated using applied radiofrequency power, nebulizer argon gas flow rate, and sample uptake flow rate by considering the intensity ratio of the Mg(II) 280.270 nm and Mg(I) 285.213 nm lines. Analytical characterization of method was assessed by limit of detection and relative standard deviation values. The certificated reference soil sample IAEA S-8 was analyzed, and the uranium determination at 367.007 nm with internal standardization using Sm at 359.260 nm has been shown to improve accuracy compared with other methods. The developed method was used for real uranium ore sample analysis.
NASA Technical Reports Server (NTRS)
Valentin, J. R.
1989-01-01
Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.
Income and functional limitations among the aged in Europe: a trend analysis in 16 countries.
von dem Knesebeck, Olaf; Vonneilich, Nico; Lüdecke, Daniel
2017-06-01
Analyses are focused on 3 research questions: (1) Are there absolute and relative income-related inequalities in functional limitations among the aged in Europe? (2) Did the absolute and relative income-related inequalities in functional limitations among the aged change between 2002 and 2014? (3) Are there differences in the changes of income-related inequalities between European countries? Data stem from 7 waves (2002-2014) of the European Social Survey. Samples of people aged 60 years or older from 16 European countries were analysed (N=63 024). Inequalities were measured by means of absolute prevalence rate differences and relative prevalence rate ratios of low versus high income. Meta-analyses with random-effect models were used to study the trends of inequalities in functional limitations over time. Functional limitations among people aged 60 years or older declined between 2002 and 2014 in most of the 16 European countries. Older people with a low income had higher rates of functional limitations and elevated rate ratios compared with people with high income. These inequalities were significant in many countries and were more pronounced among men than among women. Overall, absolute and relative income-related inequalities increased between 2002 and 2014, especially in Ireland, the Netherlands and Sweden. High-income groups are more in favour of the observed overall decline in functional limitations than deprived groups. Results point to potential income-related inequalities in compression of morbidity in the recent past in Europe. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Cowan, Dallas M; Cheng, Thales J; Ground, Matthew; Sahmel, Jennifer; Varughese, Allysha; Madl, Amy K
2015-08-01
The United States Occupational Safety and Health Administration (OSHA) maintains the Chemical Exposure Health Data (CEHD) and the Integrated Management Information System (IMIS) databases, which contain quantitative and qualitative data resulting from compliance inspections conducted from 1984 to 2011. This analysis aimed to evaluate trends in workplace asbestos concentrations over time and across industries by combining the samples from these two databases. From 1984 to 2011, personal air samples ranged from 0.001 to 175 f/cc. Asbestos compliance sampling data associated with the construction, automotive repair, manufacturing, and chemical/petroleum/rubber industries included measurements in excess of 10 f/cc, and were above the permissible exposure limit from 2001 to 2011. The utility of combining the databases was limited by the completeness and accuracy of the data recorded. In this analysis, 40% of the data overlapped between the two databases. Other limitations included sampling bias associated with compliance sampling and errors occurring from user-entered data. A clear decreasing trend in both airborne fiber concentrations and the numbers of asbestos samples collected parallels historically decreasing trends in the consumption of asbestos, and declining mesothelioma incidence rates. Although air sampling data indicated that airborne fiber exposure potential was high (>10 f/cc for short and long-term samples) in some industries (e.g., construction, manufacturing), airborne concentrations have significantly declined over the past 30 years. Recommendations for improving the existing exposure OSHA databases are provided. Copyright © 2015. Published by Elsevier Inc.
Kotrappa, Payasada; Stieff, Frederick
2009-08-01
An electret ion chamber (EIC) radon monitor in a sealed accumulator measures the integrated average radon concentration at the end of the accumulation duration. Theoretical equations have been derived to relate such radon concentrations (Bq m(-3) ) to the radon emanation rate (Bq d(-1)) from building materials enclosed in the accumulator. As an illustration, a 4-L sealable glass jar has been used as an accumulator to calculate the radon emanation rate from different granite samples. The radon emanation rate was converted into radon flux (Bq mm(-2) d(-1)) by dividing the emanation rate by surface area of the sample. Fluxes measured on typical, commercially available granites ranged from 20-30 Bq m(-2) d(-1). These results are similar to the results reported in the literature. The lower limit of detection for a 2-d measurement works out to be 7 Bq m(-2) d(-1). Equations derived can also be used for other sealable accumulators and other integrating detectors, such as alpha track detectors.
Diriba, Getu; Kebede, Abebaw; Yaregal, Zelalem; Getahun, Muluwork; Tadesse, Mengistu; Meaza, Abyot; Dagne, Zekarias; Moga, Shewki; Dilebo, Jibril; Gudena, Kebebe; Hassen, Mulu; Desta, Kassu
2017-05-10
Bacteriological confirmed active case detection remains the corner stone for diagnosing tuberculosis. Non-radiometric liquid culture system Mycobacterium Growth Indicator Tube with automated interface had been recommended by expert groups in addition to conventional solid culture media such as Lowenstein-Jensen. However in high burden resource limited countries advanced non-radiometric based tuberculosis diagnostic methods such as MGIT 960 is limited. Therefore we have evaluated the performance of MGIT 960 system compared to LJ for recovery of Mycobacterium complex (MTBC) from clinical specimens. A cross sectional study was conducted from a total of 908 samples between January 1st, 2013 to December 31st, 2014. Clinical specimens were processed following standard procedures and the final suspension was inoculated to MGIT tubes and LJ slant. Identification and confirmation of MTBC was done by ZN staining and SD Bioline test. Data was analyzed by SPSS version 20. The sensitivity, specificity, recovery rate and the average turnaround time to recover the organism was computed. From a total of 908 clinical specimens processed using both LJ and BACTEC MGIT liquid culture methods the recovery rate for LJ and MGIT, for smear positive samples was 66.7% (74/111) and 87.4% (97/ 111) respectively while for smear negative samples was 13.4% (108/797) and 17.4% (139/797) for LJ and MGIT methods respectively. The overall recovery rate for MGIT is significantly higher than LJ methods [26% (236/908; vs. 20%, 182/908, P = 0.002)]. The average turnaround time for smear positive samples was 16 and 31 days for MGIT and LJ respectively. Turnaround time for smear negative samples was 20 and 36 days for MGIT and LJ respectively. The overall agreement between MGIT and LJ was fairly good with Kappa value of 0.59 (P < 0.001). In the present study the contamination rate for MGIT is higher than the LJ methods, 15 and 9.3% respectively. The BACTEC MGIT liquid culture system has better MTBC recovery rate with shorter turnaround time for both smear positive and negative clinical specimens compared to Conventional LJ method. However, efforts should be made in order to reduce the high contamination rate in BACTEC MGIT system and to lesser extent to LJ methods.
Exposure Assessment for Italian Population Groups to Deoxynivalenol Deriving from Pasta Consumption
Brera, Carlo; Bertazzoni, Valentina; Debegnach, Francesca; Gregori, Emanuela; Prantera, Elisabetta; De Santis, Barbara
2013-01-01
Four hundred and seventy-two pasta samples were collected from long retail distribution chain sales points located in North, Central and South Italy. Representative criteria in the sample collection were followed in terms of number of samples collected, market share, and types of pasta. Samples were analysed by an accredited HPLC-UV method of analysis. The mean contamination level (64.8 μg/kg) of deoxynivalenol (DON) was in the 95th percentile (239 μg/kg) and 99th percentile (337 μg/kg), far below the legal limit (750 μg/kg) set by Regulation EC/1126/2007, accounting for about one tenth, one third and half the legal limit, respectively. Ninety-nine percent of samples fell below half the legal limit. On the basis of the obtained occurrence levels and considering the consumption rates reported by the Italian official database, no health concern was assessed for all consumer groups, being that exposure was far below the Tolerable Daily Intake (TDI) of 1000 ng/kg b.w/day. Nevertheless, despite this, particular attention should be devoted to the exposure to DON by high consumers, such as children aged 3–5 years, who could reach the TDI even with very low levels of DON contamination. PMID:24287568
Effect of Structure on the Initiation and Ignition Chemistry of Energetic Ionic Liquids
2010-06-30
Thermolysis In the confined rapid thermolysis (CRT)/FTIR/ToFMS studies, the thermal decomposition is limited to a volume confined between two heated ...Jordan) is equipped with a 1m flight tube and a 44 mm microchannel plate (MCP) detector. Here, the recharging of the MCP detector limits the...conditions achieved by initially heating the sample at rates of approximately 2000 K/s. The products formed by decomposition under the afore
Forssén, Patrik; Samuelsson, Jörgen; Fornstedt, Torgny
2014-06-20
In this study we investigated how the maximum productivity for commonly used, realistic separation system with a competitive Langmuir adsorption isotherm is affected by changes in column length, packing particle size, mobile phase viscosity, maximum allowed column pressure, column efficiency, sample concentration/solubility, selectivity, monolayer saturation capacity and retention factor of the first eluting compound. The study was performed by generating 1000 random separation systems whose optimal injection volume was determined, i.e., the injection volume that gives the largest achievable productivity. The relative changes in largest achievable productivity when one of the parameters above changes was then studied for each system and the productivity changes for all systems were presented as distributions. We found that it is almost always beneficial to use shorter columns with high pressure drops over the column and that the selectivity should be greater than 2. However, the sample concentration and column efficiency have very limited effect on the maximum productivity. The effect of packing particle size depends on the flow rate limiting factor. If the pumps maximum flow rate is the limiting factor use smaller packing, but if the pressure of the system is the limiting factor use larger packing up to about 40μm. Copyright © 2014 Elsevier B.V. All rights reserved.
A STATISTICAL SURVEY OF DIOXIN-LIKE COMPOUNDS IN ...
The USEPA and the USDA completed the first statistically designed survey of the occurrence and concentration of dibenzo-p-dioxins (CDDs), dibenzofurans (CDFs), and coplanar polychlorinated biphenyls (PCBs) in the fat of beef animals raised for human consumption in the United States. Back fat was sampled from 63 carcasses at federally inspected slaughter establishments nationwide. The sample design called for sampling beef animal classes in proportion to national annual slaughter statistics. All samples were analyzed using a modification of EPA method 1613, using isotope dilution, High Resolution GC/MS to determine the rate of occurrence of 2,3,7,8-substituted CDDs/CDFs/PCBs. The method detection limits ranged from 0.05 ng/kg for TCDD to 3 ng/kg for OCDD. The results of this survey showed a mean concentration (reported as I-TEQ, lipid adjusted) in U.S. beef animals of 0.35 ng/kg and 0.89 ng/kg for CDD/CDF TEQs when either non-detects are treated as 0 value or assigned a value of 1/2 the detection limit, respectively, and 0.51 ng/kg for coplanar PCB TEQs at both non-detect equal 0 and 1/2 detection limit. journal article
Han, X M; Zhang, H Y; Zhang, J; Xu, W J; Liu, D; Jiang, T; Xu, J; Li, F Q
2016-10-06
Objective: To investigate fungi contamination and the natural occurrence of mycotoxins in corn feed ingredients collected from China. Methods: A total of 94 corn feed ingredient samples were collected from 8 Chinese provinces(i.e., Anhui, Hebei, Heilongjiang, Jilin, Jiangsu, Liaoning, Inner Mongolia, and Shandong)in February 2014. A tandem ultra-performance liquid chromatographymass spectrometry method was used for simultaneous detection of twelve kinds of mycotoxins, including aflatoxin(AF), type A and type B tricothecenes, and zearalenone(ZEN). Contaminated fungi were also identified and counted. Results: AF was detected in 36.2%(34/94)of samples; the concentration of AFB 1 was the highest in the four AFs with the range: 0.3~181.3 μg/kg; and then followed by AFB 2 (range: 1.0-74.3 μg/kg). There were 7 samples(7.5%)with AFB 1 concentrations higher than the tolerance limit of 50 μg/kg. The concentration of type A tricothecenes in all samples was lower(0.1-10.5 μg/kg). DON had the most serious contamination than other kind of type B tricothecenes(range: 0.7-606.6 μg/kg; median: 66.3 μg/kg). The DON concentration in all samples was below the tolerance limit of 1 000 μg/kg. ZEN was detected in 76.6%(72/ 94)of samples(median: 36.9 μg/kg), with 3 samples having ZEN concentrations higher than the tolerance limit of 500 μg/kg. The survey on fungi contamination showed that all samples were contaminated by fungi(range: 5.0-1.4×10 5 CFU/g). There were 18 and 3 samples with quantities of fungi higher than the tolerance and forbidden limits, respectively. The Aspergillus , Penicillium , Fusarium , Trichoderma and Mucor genuses were the predominant fungi in corn feed ingredients, with detection rates of 71.3%(67), 60.6%(57), 71.3%(67), 27.7%(26), and 24.5%(23), respectively. The detection rate of Fusarium moniliforme , 73.4%(69/94)was higher than that of Aspergillus flavus , 41.5%(39/94). Conclusion: In this survey, the corn feed ingredients were not seriously contaminated by AF and type A tricothecenes but mainly contaminated by type B trichothecenes, including DON and its derivatives, as well as ZEN. They were also contaminated by fungi such as Aspergillus , Penicillium , and Fusarium .
Predicting discovery rates of genomic features.
Gravel, Simon
2014-06-01
Successful sequencing experiments require judicious sample selection. However, this selection must often be performed on the basis of limited preliminary data. Predicting the statistical properties of the final sample based on preliminary data can be challenging, because numerous uncertain model assumptions may be involved. Here, we ask whether we can predict "omics" variation across many samples by sequencing only a fraction of them. In the infinite-genome limit, we find that a pilot study sequencing 5% of a population is sufficient to predict the number of genetic variants in the entire population within 6% of the correct value, using an estimator agnostic to demography, selection, or population structure. To reach similar accuracy in a finite genome with millions of polymorphisms, the pilot study would require ∼15% of the population. We present computationally efficient jackknife and linear programming methods that exhibit substantially less bias than the state of the art when applied to simulated data and subsampled 1000 Genomes Project data. Extrapolating based on the National Heart, Lung, and Blood Institute Exome Sequencing Project data, we predict that 7.2% of sites in the capture region would be variable in a sample of 50,000 African Americans and 8.8% in a European sample of equal size. Finally, we show how the linear programming method can also predict discovery rates of various genomic features, such as the number of transcription factor binding sites across different cell types. Copyright © 2014 by the Genetics Society of America.
A fiber optic sensor for noncontact measurement of shaft speed, torque, and power
NASA Technical Reports Server (NTRS)
Madzsar, George C.
1990-01-01
A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.
A fiber optic sensor for noncontact measurement of shaft speed, torque and power
NASA Technical Reports Server (NTRS)
Madzsar, George C.
1990-01-01
A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.
Porte, Lorena; Varela, Carmen; Haecker, Thomas; Morales, Sara; Weitzel, Thomas
2016-05-13
Campylobacter is a leading cause of bacterial gastroenteritis, but sensitive diagnostic methods such as culture are expensive and often not available in resource limited settings. Therefore, direct staining techniques have been developed as a practical and economical alternative. We analyzed the impact of replacing Campylobacter staining with culture for routine stool examinations in a private hospital in Chile. From January to April 2014, a total of 750 consecutive stool samples were examined in parallel by Hucker stain and Campylobacter culture. Isolation rates of Campylobacter were determined and the performance of staining was evaluated against culture as the gold standard. Besides, isolation rates of Campylobacter and other enteric pathogens were compared to those of past years. Campylobacter was isolated by culture in 46 of 750 (6.1 %) stool samples. Direct staining only identified three samples as Campylobacter positive and reached sensitivity and specificity values of 6.5 and 100 %, respectively. In comparison to staining-based detection rates of previous years, we observed a significant increase of Campylobacter cases in our patients. Direct staining technique for Campylobacter had a very low sensitivity compared to culture. Staining methods might lead to a high rate of false negative results and an underestimation of the importance of campylobacteriosis. With the inclusion of Campylobacter culture, this pathogen became a leading cause of intestinal infection in our patient population.
Kabir, Md Humayun; Abd El-Aty, A M; Rahman, Md Musfiqur; Kim, Sung-Woo; Choi, Jeong-Heui; Lee, Young-Jun; Truong, Lieu T B; Lee, Kang-Bong; Kim, Mi-Ra; Shin, Ho-Chul; Shim, Jae-Han
2017-05-01
This study was undertaken to quantify the residue levels and propose the dissipation kinetics of thiacloprid formulated as suspension concentrate in field-incurred Asian pears grown under two different open-field conditions. Samples were extracted with 20% distilled water in acetonitrile; partitioned with brine water and dichloromethane; and purified with a Florisil solid phase extraction cartridge. The analyte was identified with an LC ultraviolet detector, and field-incurred samples were confirmed using LC-MS/MS. The calibration curve was linear over the range 0.05-5.0 mg/L with a satisfactory coefficient of determination (R 2 = 0.9994). The limits of detection and limits of quantification (LOQ) were 0.003 and 0.01 mg/kg, respectively. The recovery rate fortified to blank samples at LOQ, 10× LOQ, and the maximum residue limit (MRL) were between 73.7 and 86.2% with relative standard deviation ≤9.0%. The residual concentrations at both sites were considerably lower than the MRL (0.7 mg/kg) set by the Korean Ministry of Food Drug Safety, with biological half-lives of 5.0 and 7.4 days, for sites 1 and 2, respectively. From the pre-harvest residue limit curve, it was predicted that if the residues were <1.13 or 1.40 mg/kg 10 days before harvest, the residue level would be lower than the MRL during harvest. Risk assessment on day 0 showed an acceptable daily intake (%) of 13.0% and 11.0% for sites 1 and site 2, respectively, which indicates that the residual amounts are not hazardous to the Korean population. Copyright © 2016 John Wiley & Sons, Ltd.
Juvenile-Onset OCD: Clinical Features in Children, Adolescents and Adults
Mancebo, Maria C.; Garcia, Abbe M.; Pinto, Anthony; Freeman, Jennifer B.; Przeworski, Amy; Stout, Robert; Kane, Joshua S.; Eisen, Jane L.; Rasmussen, Steven A.
2009-01-01
Objective To examine clinical correlates of juvenile-onset OCD across the lifespan. Method Intake data collected from 257 consecutive participants with a juvenile-onset of OCD (20 children, 44 adolescents, and 193 adults) in a naturalistic study of the clinical course of OCD were examined. Participants and parents of juvenile participants completed a structured diagnostic interview, rater-administered severity measures, and self-report questionnaires. Results Children and adolescents (i.e. juveniles) shared similar features with the exception of age at onset and OCD symptom expression. Clinically meaningful differences between juvenile and adult participants were also found. Compared to adults, juveniles were more likely to be male, recall an earlier age at OCD onset, and have different lifetime comorbidity patterns. Conclusion Juvenile-onset OCD symptom expression is remarkably similar across the lifespan. However, findings also suggest clinically meaningful differences between juveniles and adults. Future work using a prospective design will improve our understanding of course patterns of juvenile-onset OCD. Significant Outcomes •Children were less likely than either adolescent or adults to report aggressive obsessions and mental rituals. •Males were overrepresented in the juvenile sample but gender was equally distributed in the adult sample •Compared to lifetime comorbidity patterns of adults, juveniles showed elevated rates of ADHD and lower rates of mood, substance use and eating disorders Limitations •The cross-sectional design with retrospective recall regarding course prior to study entry limits conclusions about the course of OCD. •The adult sample is limited to adults whose symptoms persisted into adulthood and therefore results cannot be generalized to all individuals with a juvenile-onset. •The small number of very young children (under age 10) may have limited power to detect differences among children and adolescents. PMID:18699949
The plane strain shear fracture of the advanced high strength steels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Li, E-mail: li.sun@gm.com
2013-12-16
The “shear fracture” which occurs at the high-curvature die radii in the sheet metal forming has been reported to remarkably limit the application of the advanced high strength steels (AHSS) in the automobile industry. However, this unusual fracture behavior generally cannot be predicted by the traditional forming limit diagram (FLD). In this research, a new experimental system was developed in order to simulate the shear fracture, especially at the plane strain state which is the most common state in the auto-industry and difficult to achieve in the lab due to sample size. Furthermore, the system has the capability to operatemore » in a strain rate range from quasi-static state to the industrial forming state. One kinds of AHSS, Quenching-Partitioning (QP) steels have been performed in this test and the results show that the limiting fracture strain is related to the bending ratio and strain rate. The experimental data support that deformation-induced heating is an important cause of “shear fracture” phenomena for AHSS: a deformation-induced quasi-heating caused by smaller bending ratio and high strain rate produce a smaller limiting plane strain and lead a “shear fracture” in the component.« less
NASA Astrophysics Data System (ADS)
Parry, James Roswell
Fission track analysis (FTA) has many uses in the scientific community including but not limited to geological dating, neutron flux mapping, and dose reconstruction. The common method of fission for FTA is through neutrons from a nuclear reactor. This dissertation investigates the use of bremsstrahlung radiation produced from an electron linear accelerator to induce fission in FTA samples. This provides a means of simultaneously measuring the amount of Pu-239, U-nat, and Th-232 in a single sample. The benefit of measuring the three isotopes simultaneously is the possible elimination of costly and time consuming chemical processing for dose reconstruction samples. Samples containing the three isotopes were irradiated in two different bremsstrahlung spectra and a neutron spectrum to determine the amount of Pu-239, U-nat, and Th-232 in the samples. The reaction rate from the calibration samples and the counted fission tracks on the samples were used in determining the concentration of each isotope in the samples. The results were accurate to within a factor of two or three, showing that the method can work to predict the concentrations of multiple isotopes in a sample. The limitations of current accelerators and detectors limits the application of this specific procedure to higher concentrations of isotopes. The method detection limits for Pu-239, U-nat, and Th-232 are 20 pCi, 1 fCi, and 0.4 flCI respectively. Analysis of extremely low concentrations of isotopes would require the use of different detectors such as quartz due to the embrittlement encountered in the Lexan at high exposures. Cracking of the Texan detectors started to appear at a fluence of about 2 x 1018 electrons from the accelerator. This may be partly due to the beam stop not being an adequate thickness. The procedure is likely limited to specialty applications for the near term. However, with the world concerns of exposure to depleted uranium, this procedure may find applications in this area since it would be simple to adapt the procedure to depleted uranium detection.
Gottesfeld, Perry; Andrew, Damian; Dalhoff, Jeffrey
2015-01-01
Gold miners exposed to crystalline silica are at risk of silicosis, lung cancer, and experience higher incidence rates of pulmonary tuberculosis (TB). Although the hazards associated with mercury exposure in artisanal small-scale gold mining (ASGM) have been well documented, no published data was available on crystalline silica exposures in this population. Air sampling was conducted in the breathing zone of workers in five villages in Tanzania with battery-operated sampling pumps and bulk samples were collected to measure the type and concentration of crystalline silica in the ore. Samples were analyzed at an accredited laboratory with X-ray diffraction. Airborne crystalline silica exposures exceeded recommended limits for all tasks monitored with an average exposure of 16.85 mg/m(3) for underground drilling that was 337 fold greater than the recommended exposure limit (REL) published by the U.S. National Institute for Occupational Safety and Health (NIOSH) and 0.19 mg/m(3) for aboveground operations or 4-fold greater than the REL. The exposures measured raise concern for possible acute and chronic silicosis and are known to significantly contribute to TB incidence rates in mining communities. The use of wet methods could greatly reduce exposures and the risk of TB and silicosis in ASGM. Ongoing efforts to address mercury and other hazards in ASGM should incorporate crystalline silica dust controls.
Detection of bacteria in suspension using a superconducting Quantum interference device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grossman, H.L.; Myers, W.R.; Vreeland, V.J.
2003-06-09
We demonstrate a technique for detecting magnetically-labeled Listeria monocytogenes and for measuring the binding rate between antibody-linked magnetic particles and bacteria. This assay, which is both sensitive and straightforward to perform, can quantify specific bacteria in a sample without the need to immobilize the bacteria or wash away unbound magnetic particles. In the measurement, we add 50 nm diameter superparamagnetic particles, coated with antibodies, to a liquid sample containing L. monocytogenes. We apply a pulsed magnetic field to align the magnetic dipole moments and use a high transition temperature Superconducting Quantum Interference Device (SQUID), an extremely sensitive detector of magneticmore » flux, to measure the magnetic relaxation signal when the field is turned off. Unbound particles randomize direction by Brownian rotation too quickly to be detected. In contrast, particles bound to L. monocytogenes are effectively immobilized and relax in about 1 s by rotation of the internal dipole moment. This Neel relaxation process is detected by the SQUID. The measurements indicate a detection limit of (5.6 {+-} 1.1) x 10{sup 6} L. monocytogenes for a 20 {micro}L sample volume. If the sample volume were reduced to 1 nL, we estimate that the detection limit could be improved to 230 {+-} 40 L. monocytogenes cells. Time-resolved measurements yield the binding rate between the particles and bacteria.« less
Digital Front End for Wide-Band VLBI Science Receiver
NASA Technical Reports Server (NTRS)
Jongeling, Andre; Sigman, Elliott; Navarro, Robert; Goodhart, Charles; Rogstad, Steve; Chandra, Kumar; Finley, Sue; Trinh, Joseph; Soriano, Melissa; White, Les;
2006-01-01
An upgrade to the very-long-baseline-interferometry (VLBI) science receiver (VSR) a radio receiver used in NASA's Deep Space Network (DSN) is currently being implemented. The current VSR samples standard DSN intermediate- frequency (IF) signals at 256 MHz and after digital down-conversion records data from up to four 16-MHz baseband channels. Currently, IF signals are limited to the 265-to-375-MHz range, and recording rates are limited to less than 80 Mbps. The new digital front end, denoted the Wideband VSR, provides improvements to enable the receiver to process wider bandwidth signals and accommodate more data channels for recording. The Wideband VSR utilizes state-of-the-art commercial analog-to-digital converter and field-programmable gate array (FPGA) integrated circuits, and fiber-optic connections in a custom architecture. It accepts IF signals from 100 to 600 MHz, sampling the signal at 1.28 GHz. The sample data are sent to a digital processing module, using a fiber-optic link for isolation. The digital processing module includes boards designed around an Advanced Telecom Computing Architecture (ATCA) industry-standard backplane. Digital signal processing implemented in FPGAs down-convert the data signals in up to 16 baseband channels with programmable bandwidths from 1 kHz to 16 MHz. Baseband samples are transmitted to a computer via multiple Ethernet connections allowing recording to disk at rates of up to 1 Gbps.
NASA Astrophysics Data System (ADS)
Gunawardhana, M. L. P.; Hopkins, A. M.; Bland-Hawthorn, J.; Brough, S.; Sharp, R.; Loveday, J.; Taylor, E.; Jones, D. H.; Lara-López, M. A.; Bauer, A. E.; Colless, M.; Owers, M.; Baldry, I. K.; López-Sánchez, A. R.; Foster, C.; Bamford, S.; Brown, M. J. I.; Driver, S. P.; Drinkwater, M. J.; Liske, J.; Meyer, M.; Norberg, P.; Robotham, A. S. G.; Ching, J. H. Y.; Cluver, M. E.; Croom, S.; Kelvin, L.; Prescott, M.; Steele, O.; Thomas, D.; Wang, L.
2013-08-01
Measurements of the low-z Hα luminosity function, Φ, have a large dispersion in the local number density of sources (˜0.5-1 Mpc-3 dex-1), and correspondingly in the star formation rate density (SFRD). The possible causes for these discrepancies include limited volume sampling, biases arising from survey sample selection, different methods of correcting for dust obscuration and active galactic nucleus contamination. The Galaxy And Mass Assembly (GAMA) survey and Sloan Digital Sky Survey (SDSS) provide deep spectroscopic observations over a wide sky area enabling detection of a large sample of star-forming galaxies spanning 0.001 < SFRHα (M⊙ yr- 1) < 100 with which to robustly measure the evolution of the SFRD in the low-z Universe. The large number of high-SFR galaxies present in our sample allow an improved measurement of the bright end of the luminosity function, indicating that the decrease in Φ at bright luminosities is best described by a Saunders functional form rather than the traditional Schechter function. This result is consistent with other published luminosity functions in the far-infrared and radio. For GAMA and SDSS, we find the r-band apparent magnitude limit, combined with the subsequent requirement for Hα detection leads to an incompleteness due to missing bright Hα sources with faint r-band magnitudes.
DNA Barcoding through Quaternary LDPC Codes
Tapia, Elizabeth; Spetale, Flavio; Krsticevic, Flavia; Angelone, Laura; Bulacio, Pilar
2015-01-01
For many parallel applications of Next-Generation Sequencing (NGS) technologies short barcodes able to accurately multiplex a large number of samples are demanded. To address these competitive requirements, the use of error-correcting codes is advised. Current barcoding systems are mostly built from short random error-correcting codes, a feature that strongly limits their multiplexing accuracy and experimental scalability. To overcome these problems on sequencing systems impaired by mismatch errors, the alternative use of binary BCH and pseudo-quaternary Hamming codes has been proposed. However, these codes either fail to provide a fine-scale with regard to size of barcodes (BCH) or have intrinsic poor error correcting abilities (Hamming). Here, the design of barcodes from shortened binary BCH codes and quaternary Low Density Parity Check (LDPC) codes is introduced. Simulation results show that although accurate barcoding systems of high multiplexing capacity can be obtained with any of these codes, using quaternary LDPC codes may be particularly advantageous due to the lower rates of read losses and undetected sample misidentification errors. Even at mismatch error rates of 10−2 per base, 24-nt LDPC barcodes can be used to multiplex roughly 2000 samples with a sample misidentification error rate in the order of 10−9 at the expense of a rate of read losses just in the order of 10−6. PMID:26492348
DNA Barcoding through Quaternary LDPC Codes.
Tapia, Elizabeth; Spetale, Flavio; Krsticevic, Flavia; Angelone, Laura; Bulacio, Pilar
2015-01-01
For many parallel applications of Next-Generation Sequencing (NGS) technologies short barcodes able to accurately multiplex a large number of samples are demanded. To address these competitive requirements, the use of error-correcting codes is advised. Current barcoding systems are mostly built from short random error-correcting codes, a feature that strongly limits their multiplexing accuracy and experimental scalability. To overcome these problems on sequencing systems impaired by mismatch errors, the alternative use of binary BCH and pseudo-quaternary Hamming codes has been proposed. However, these codes either fail to provide a fine-scale with regard to size of barcodes (BCH) or have intrinsic poor error correcting abilities (Hamming). Here, the design of barcodes from shortened binary BCH codes and quaternary Low Density Parity Check (LDPC) codes is introduced. Simulation results show that although accurate barcoding systems of high multiplexing capacity can be obtained with any of these codes, using quaternary LDPC codes may be particularly advantageous due to the lower rates of read losses and undetected sample misidentification errors. Even at mismatch error rates of 10(-2) per base, 24-nt LDPC barcodes can be used to multiplex roughly 2000 samples with a sample misidentification error rate in the order of 10(-9) at the expense of a rate of read losses just in the order of 10(-6).
Liu, Weisong; Huang, Zhitao; Wang, Xiang; Sun, Weichao
2017-01-01
In a cognitive radio sensor network (CRSN), wideband spectrum sensing devices which aims to effectively exploit temporarily vacant spectrum intervals as soon as possible are of great importance. However, the challenge of increasingly high signal frequency and wide bandwidth requires an extremely high sampling rate which may exceed today’s best analog-to-digital converters (ADCs) front-end bandwidth. Recently, the newly proposed architecture called modulated wideband converter (MWC), is an attractive analog compressed sensing technique that can highly reduce the sampling rate. However, the MWC has high hardware complexity owing to its parallel channel structure especially when the number of signals increases. In this paper, we propose a single channel modulated wideband converter (SCMWC) scheme for spectrum sensing of band-limited wide-sense stationary (WSS) signals. With one antenna or sensor, this scheme can save not only sampling rate but also hardware complexity. We then present a new, SCMWC based, single node CR prototype System, on which the spectrum sensing algorithm was tested. Experiments on our hardware prototype show that the proposed architecture leads to successful spectrum sensing. And the total sampling rate as well as hardware size is only one channel’s consumption of MWC. PMID:28471410
Determining water sensitive card spread factors for real world tank mixes
USDA-ARS?s Scientific Manuscript database
The use of water sensitive cards provides a quick and easy method to sample the coverage and deposition from spray applications. Typically, this measure is limited to percent coverage as measures of droplet size, and thus deposition rate, are highly influenced by the stain diameter resulting from t...
ERIC Educational Resources Information Center
Begeny, John C.; Krouse, Hailey E.; Brown, Kristina G.; Mann, Courtney M.
2011-01-01
Teacher judgments about students' academic abilities are important for instructional decision making and potential special education entitlement decisions. However, the small number of studies evaluating teachers' judgments are limited methodologically (e.g., sample size, procedural sophistication) and have yet to answer important questions…
Ozkantar, Nebiye; Yilmaz, Erkan; Soylak, Mustafa; Tuzen, Mustafa
2015-08-01
A solid-phase extraction method for separation and preconcentration of Ir(IV) ion by using activated carbon cloth (ACC) has been presented. Ir(IV) as their 1-(2-pyridylazo) 2-naphtol (PAN) chelate was adsorbed on ACC at pH 2.0 and was eluted from ACC with acidic dimethylformamide (DMF). The Ir(IV) concentration was determined at 536 nm as Ir(IV)-PAN complex by using UV-vis spectrophotometer. The analytical parameters including pH, sample and eluent flow rates, amount of PAN, eluent type, concentration, and sample volume were optimized. The effects of foreign ions on the recoveries of iridium were also investigated. The preconcentration factor was calculated as 60. The limit of detection (LOD) and the limit of quantification (LOQ) of the method were found as 0.039 and 0.129 μg L(-1), respectively. The method was applied to soil and water samples for iridium determination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Hao; Mey, Antonia S. J. S.; Noé, Frank
2014-12-07
We propose a discrete transition-based reweighting analysis method (dTRAM) for analyzing configuration-space-discretized simulation trajectories produced at different thermodynamic states (temperatures, Hamiltonians, etc.) dTRAM provides maximum-likelihood estimates of stationary quantities (probabilities, free energies, expectation values) at any thermodynamic state. In contrast to the weighted histogram analysis method (WHAM), dTRAM does not require data to be sampled from global equilibrium, and can thus produce superior estimates for enhanced sampling data such as parallel/simulated tempering, replica exchange, umbrella sampling, or metadynamics. In addition, dTRAM provides optimal estimates of Markov state models (MSMs) from the discretized state-space trajectories at all thermodynamic states. Under suitablemore » conditions, these MSMs can be used to calculate kinetic quantities (e.g., rates, timescales). In the limit of a single thermodynamic state, dTRAM estimates a maximum likelihood reversible MSM, while in the limit of uncorrelated sampling data, dTRAM is identical to WHAM. dTRAM is thus a generalization to both estimators.« less
Compressed NMR: Combining compressive sampling and pure shift NMR techniques.
Aguilar, Juan A; Kenwright, Alan M
2017-12-26
Historically, the resolution of multidimensional nuclear magnetic resonance (NMR) has been orders of magnitude lower than the intrinsic resolution that NMR spectrometers are capable of producing. The slowness of Nyquist sampling as well as the existence of signals as multiplets instead of singlets have been two of the main reasons for this underperformance. Fortunately, two compressive techniques have appeared that can overcome these limitations. Compressive sensing, also known as compressed sampling (CS), avoids the first limitation by exploiting the compressibility of typical NMR spectra, thus allowing sampling at sub-Nyquist rates, and pure shift techniques eliminate the second issue "compressing" multiplets into singlets. This paper explores the possibilities and challenges presented by this combination (compressed NMR). First, a description of the CS framework is given, followed by a description of the importance of combining it with the right pure shift experiment. Second, examples of compressed NMR spectra and how they can be combined with covariance methods will be shown. Copyright © 2017 John Wiley & Sons, Ltd.
Response of Microbial Soil Carbon Mineralization Rates to Oxygen Limitations
NASA Astrophysics Data System (ADS)
Keiluweit, M.; Denney, A.; Nico, P. S.; Fendorf, S. E.
2014-12-01
The rate of soil organic matter (SOM) mineralization is known to be controlled by climatic factors as well as molecular structure, mineral-organic associations, and physical protection. What remains elusive is to what extent oxygen (O2) limitations impact overall rates of microbial SOM mineralization (oxidation) in soils. Even within upland soils that are aerobic in bulk, factors limiting O2 diffusion such as texture and soil moisture can result in an abundance of anaerobic microsites in the interior of soil aggregates. Variation in ensuing anaerobic respiration pathways can further impact SOM mineralization rates. Using a combination of (first) aggregate model systems and (second) manipulations of intact field samples, we show how limitations on diffusion and carbon bioavailability interact to impose anaerobic conditions and associated respiration constraints on SOM mineralization rates. In model aggregates, we examined how particle size (soil texture) and amount of dissolved organic carbon (bioavailable carbon) affect O2 availability and distribution. Monitoring electron acceptor profiles (O2, NO3-, Mn and Fe) and SOM transformations (dissolved, particulate, mineral-associated pools) across the resulting redox gradients, we then determined the distribution of operative microbial metabolisms and their cumulative impact on SOM mineralization rates. Our results show that anaerobic conditions decrease SOM mineralization rates overall, but those are partially offset by the concurrent increases in SOM bioavailability due to transformations of protective mineral phases. In intact soil aggregates collected from soils varying in texture and SOM content, we mapped the spatial distribution of anaerobic microsites. Optode imaging, microsensor profiling and 3D tomography revealed that soil texture regulates overall O2 availability in aggregate interiors, while particulate SOM in biopores appears to control the fine-scale distribution of anaerobic microsites. Collectively, our results suggest that texture and particulate organic matter content are useful predictors for the impact of O2 limitations on SOM mineralization rates.
NASA Astrophysics Data System (ADS)
Villa, Carlos; Kumavor, Patrick; Donkor, Eric
2008-04-01
Photonics Analog-to-Digital Converters (ADCs) utilize a train of optical pulses to sample an electrical input waveform applied to an electrooptic modulator or a reverse biased photodiode. In the former, the resulting train of amplitude-modulated optical pulses is detected (converter to electrical) and quantized using a conversional electronics ADC- as at present there are no practical, cost-effective optical quantizers available with performance that rival electronic quantizers. In the latter, the electrical samples are directly quantized by the electronics ADC. In both cases however, the sampling rate is limited by the speed with which the electronics ADC can quantize the electrical samples. One way to increase the sampling rate by a factor N is by using the time-interleaved technique which consists of a parallel array of N electrical ADC converters, which have the same sampling rate but different sampling phase. Each operating at a quantization rate of fs/N where fs is the aggregated sampling rate. In a system with no real-time operation, the N channels digital outputs are stored in memory, and then aggregated (multiplexed) to obtain the digital representation of the analog input waveform. Alternatively, for real-time operation systems the reduction of storing time in the multiplexing process is desired to improve the time response of the ADC. The complete elimination of memories come expenses of concurrent timing and synchronization in the aggregation of the digital signal that became critical for a good digital representation of the analog signal waveform. In this paper we propose and demonstrate a novel optically synchronized encoder and multiplexer scheme for interleaved photonics ADCs that utilize the N optical signals used to sample different phases of an analog input signal to synchronize the multiplexing of the resulting N digital output channels in a single digital output port. As a proof of concept, four 320 Megasamples/sec 12-bit of resolution digital signals were multiplexed to form an aggregated 1.28 Gigasamples/sec single digital output signal.
Mevik, Kjersti; Griffin, Frances A; Hansen, Tonje E; Deilkås, Ellen T; Vonen, Barthold
2016-04-25
To investigate the impact of increasing sample of records reviewed bi-weekly with the Global Trigger Tool method to identify adverse events in hospitalised patients. Retrospective observational study. A Norwegian 524-bed general hospital trust. 1920 medical records selected from 1 January to 31 December 2010. Rate, type and severity of adverse events identified in two different samples sizes of records selected as 10 and 70 records, bi-weekly. In the large sample, 1.45 (95% CI 1.07 to 1.97) times more adverse events per 1000 patient days (39.3 adverse events/1000 patient days) were identified than in the small sample (27.2 adverse events/1000 patient days). Hospital-acquired infections were the most common category of adverse events in both the samples, and the distributions of the other categories of adverse events did not differ significantly between the samples. The distribution of severity level of adverse events did not differ between the samples. The findings suggest that while the distribution of categories and severity are not dependent on the sample size, the rate of adverse events is. Further studies are needed to conclude if the optimal sample size may need to be adjusted based on the hospital size in order to detect a more accurate rate of adverse events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Infrascrotal, perineal, femorofemoral bypass for arterial graft infection at the groin.
Illuminati, Giulo; Caliò, Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca
2004-12-01
Infrascrotal, perineal, femorofemoral bypass is an acceptable procedure for treating infection of a prosthetic arterial graft limited to a unilateral groin. A consecutive sample clinical study with a mean follow-up of 29 months. The surgical department of an academic tertiary care center and an affiliated secondary care center. Nineteen patients with a mean age of 68 years with prosthetic graft infection at the outflow anastomosis on a femoral artery at the Scarpa triangle underwent an infrascrotal, perineal, femorofemoral bypass, with excision of the graft material limited at the groin. The recipient artery was the profunda femoris artery in 12 cases, the superficial femoral in 5, and the distal common femoral artery in 2. Cumulative survival, recurrence of sepsis, primary graft patency, and limb salvage rates expressed by standard life-table analysis. Postoperative mortality rate was 5%. Cumulative (SE) survival rate was 65% (11.6%) at 3 years. Cumulative (SE) rate of freedom from recurrent sepsis was 88% (8.6%) at 3 years. Cumulative (SE) primary patency and limb salvage rates were 86% (9.4%) and 91% (7.9%), respectively, at 3 years. Femorofemoral bypass with an infrascrotal perineal approach is a valuable procedure for the treatment of femoral arterial graft infection limited at a unilateral groin.
Infrascrotal, Perineal, Femorofemoral Bypass for Arterial Graft Infection at the Groin.
Illuminati, Giulio; Caliò, Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca
2004-12-01
HYPOTHESIS: Infrascrotal, perineal, femorofemoral bypass is an acceptable procedure for treating infection of a prosthetic arterial graft limited to a unilateral groin. DESIGN: A consecutive sample clinical study with a mean follow-up of 29 months. SETTING: The surgical department of an academic tertiary care center and an affiliated secondary care center. PATIENTS: Nineteen patients with a mean age of 68 years with prosthetic graft infection at the outflow anastomosis on a femoral artery at the Scarpa triangle underwent an infrascrotal, perineal, femorofemoral bypass, with excision of the graft material limited at the groin. The recipient artery was the profunda femoris artery in 12 cases, the superficial femoral in 5, and the distal common femoral artery in 2. MAIN OUTCOME MEASURES: Cumulative survival, recurrence of sepsis, primary graft patency, and limb salvage rates expressed by standard life-table analysis. RESULTS: Postoperative mortality rate was 5%. Cumulative (SE) survival rate was 65% (11.6%) at 3 years. Cumulative (SE) rate of freedom from recurrent sepsis was 88% (8.6%) at 3 years. Cumulative (SE) primary patency and limb salvage rates were 86% (9.4%) and 91% (7.9%), respectively, at 3 years. CONCLUSION: Femorofemoral bypass with an infrascrotal perineal approach is a valuable procedure for the treatment of femoral arterial graft infection limited at a unilateral groin.
Metallographic cooling rates of L-group ordinary chondrites
NASA Technical Reports Server (NTRS)
Bennett, Marvin E.; Mcsween, Harry Y., Jr.
1993-01-01
Shock metamorphism appears to be a ubiquitous feature in L-group ordinary chondrites. Brecciation and heterogeneous melting obscure much of the early history of this meteorite group and have caused confusion as to whether L chondrites have undergone thermal metamorphism within onion-shell or rubble-pile parent bodies. Employing the most recent shock criteria, we have examined 55 Antarctic and 24 non-Antarctic L chondrites in order to identify those which have been least affected by post-accretional shock. Six low-shock samples (those with shock grade less than S4) of petrographic types L3-L5 were selected from both populations and metallographic cooling rates were obtained following the technique of Willis and Goldstein. All non-Antarctic L6 chondrites inspected were too heavily shocked to be included in this group. However, 4 shocked L6 chondrites were analyzed in order to determine what effects shock may impose on metallographic cooling rates. Metallographic cooling rates were derived by analyzing the cores of taenite grains and then measuring the distance to the nearest grain edge. Taenites were identified using backscatter imaging on a Cameca SX-50 electron microprobe. Using backscatter we were able to locate homogeneous, rust-free, nearly spherical grains. M-shaped profiles taken from grain traverses were also used to help locate the central portions of selected grains. All points which contained phosphorus above detection limits were discarded. Plots of cooling-rate data are summarized and data from the high-shock samples are presented. The lack of coherency of cooling rates for individual samples is indicative of heterogeneous cooling following shock. The data confirms the statement expressed by numerous workers that extreme care must be taken when selecting samples of L chondrites for cooling-rate studies. Data for the 6 non-Antarctic low-shock samples are also presented. The samples display a general trend in cooling rates. The lowest metamorphic grade yielded the slowest cooling rates and an increase in grade follows an increase in cooling rate. This is the opposite relationship to that predicted by the onion-shell model.
NASA Astrophysics Data System (ADS)
Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.
2017-02-01
A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.
Flux-limited sample of Galactic carbon stars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Claussen, M.J.; Kleinmann, S.G.; Joyce, R.R.
Published observational data (including IRAS observations) for a flux-limited sample of 215 Galactic carbon stars (CSs) selected from the 2-micron sky survey of Neugebauer and Leighton (1969) are compiled in extensive tables and graphs and analyzed statistically. The sample is found to penetrate a volume of radius 1.5 kpc, and the local CS space density and surface density are calculated as log rho0 (per cu kpc) = 2.0 + or - 0.4 and log N (per sq kpc) = 1.6 + or - 0.2, respectively. The total Galactic mass-return rate from these CSs is estimated as 0.013 solar mass/yr, implyingmore » a time scale of 0.1-1 Myr for the CS evolutionary phase and a mass of 1.2-1.6 solar mass for the (probably F-type) main-seqence progenitors of CSs. 81 references.« less
Analytical and sampling constraints in ²¹⁰Pb dating.
MacKenzie, A B; Hardie, S M L; Farmer, J G; Eades, L J; Pulford, I D
2011-03-01
²¹⁰Pb dating provides a valuable, widely used means of establishing recent chronologies for sediments and other accumulating natural deposits. The Constant Rate of Supply (CRS) model is the most versatile and widely used method for establishing ²¹⁰Pb chronologies but, when using this model, care must be taken to account for limitations imposed by sampling and analytical factors. In particular, incompatibility of finite values for empirical data, which are constrained by detection limit and core length, with terms in the age calculation, which represent integrations to infinity, can generate erroneously old ages for deeper sections of cores. The bias in calculated ages increases with poorer limit of detection and the magnitude of the disparity increases with age. The origin and magnitude of this effect are considered below, firstly for an idealized, theoretical ²¹⁰Pb profile and secondly for a freshwater lake sediment core. A brief consideration is presented of the implications of this potential artefact for sampling and analysis. Copyright © 2011 Elsevier B.V. All rights reserved.
Evaluating the influence of stress on the dislocation creep flow law for quartz
NASA Astrophysics Data System (ADS)
Tokle, L.; Hirth, G.
2017-12-01
Due to the abundance of quartz in the continental crust, quartz rheology is fundamental to our understanding of many geodynamic processes. Microstructures in many naturally deformed quartzites deformed at ductile conditions, indicate that dislocation creep is a common deformation mechanism in quartz at crustal conditions. The dislocation creep flow laws for quartz were constructed based on deformation experiments on aggregates at temperatures from 900 to 1100°C and strain rates of 10-5-10-6 s-1. Hirth et al. (2001) point out that these flow laws underestimate sample strengths for experiments conducted below 900°C; yet samples deformed as low as 700°C exhibit dislocation creep microstructures. To address this discrepancy, we compared 14 different studies on experimentally deformed wet quartzite aggregates ranging in temperature from 700 to 1100°C. Our analysis shows that two clear trends develop, one with a power-law stress exponent of n = 4 and the other, at a higher stress, with a stress exponent of n = 3. This change suggests a transition in the rate-limiting process; further, the conditions where the transition in stress exponent occurs correlate well with changes in quartz c-axis fabrics in general shear experiments. At low stresses, quartz fabrics are defined by a Y-max, indicating prism slip, while at higher stresses quartz fabrics are defined by basal slip. Our interpretation is that the c-axis fabrics represent the easy slip system in quartz and hypothesize that basal slip is rate-limiting at low stresses while prism is rate-limiting at high stresses. A change in the stress exponent has significant consequences for our understanding of high stress tectonic environments, such as the brittle-ductile transition and sediment rheology in a subducting slab.
Coggins, Marie A; Healy, Catherine B; Lee, Taekhee; Harper, Martin
2014-01-01
Restoration stone work regularly involves work with high-silica-content materials (e.g., sandstone), but low-silica-content materials (<2 % quartz) such as limestone and lime mortar are also used. A combination of short sample duration and low silica content makes the quantification of worker exposure to respirable crystalline silica (RCS) difficult. This problem will be further compounded by the introduction of lower occupational exposure standards for RCS. The objective of this work was to determine whether higher-flow samplers might be an effective tool in characterizing lower RCS concentrations. A short study was performed to evaluate the performance of three high-flow samplers (FSP10, CIP10-R, and GK2.69) using side-by-side sampling with low-flow samplers (SIMPEDS and 10-mm nylon cyclones) for RCS exposure measurement at a restoration stonemasonry field site. A total of 19 side-by-side sample replicates for each high-flow and low-flow sampler pair were collected from work tasks involving limestone and sandstone. Most of the RCS (quartz) masses collected with the high-flow-rate samplers were above the limit of detection (62 % to 84 %) relative to the low-flow-rate samplers (58 % to 78 %). The average of the respirable mass concentration ratios for CIP10-R/SIMPEDS, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs and the range of the quartz concentration ratios for the CIP10-R/SIMPEDS, CIP10-R/10-mm nylon, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs included unity with an average close to unity, indicating no likely difference between the reported values for each sampler. Workers reported problems related to the weight of the sampling pumps for the high-flow-rate samplers. Respirable mass concentration data suggest that the high-flow-rate samplers evaluated would be appropriate for sampling respirable dust concentrations during restoration stone work. Results from the comparison of average quartz concentration ratios between high-and low-flow samplers suggest that the higher mass collected by the high-flow-rate samplers did not interfere with the quartz measurement. A sig-nificant portion of the data collected with the high-flow-rate samplers (>82 %) were greater than the limit of detection, which indicates that these samplers are suitable for quantifying exposures, even with low-quartz materials.
Adaptive Sampling of Time Series During Remote Exploration
NASA Technical Reports Server (NTRS)
Thompson, David R.
2012-01-01
This work deals with the challenge of online adaptive data collection in a time series. A remote sensor or explorer agent adapts its rate of data collection in order to track anomalous events while obeying constraints on time and power. This problem is challenging because the agent has limited visibility (all its datapoints lie in the past) and limited control (it can only decide when to collect its next datapoint). This problem is treated from an information-theoretic perspective, fitting a probabilistic model to collected data and optimizing the future sampling strategy to maximize information gain. The performance characteristics of stationary and nonstationary Gaussian process models are compared. Self-throttling sensors could benefit environmental sensor networks and monitoring as well as robotic exploration. Explorer agents can improve performance by adjusting their data collection rate, preserving scarce power or bandwidth resources during uninteresting times while fully covering anomalous events of interest. For example, a remote earthquake sensor could conserve power by limiting its measurements during normal conditions and increasing its cadence during rare earthquake events. A similar capability could improve sensor platforms traversing a fixed trajectory, such as an exploration rover transect or a deep space flyby. These agents can adapt observation times to improve sample coverage during moments of rapid change. An adaptive sampling approach couples sensor autonomy, instrument interpretation, and sampling. The challenge is addressed as an active learning problem, which already has extensive theoretical treatment in the statistics and machine learning literature. A statistical Gaussian process (GP) model is employed to guide sample decisions that maximize information gain. Nonsta tion - ary (e.g., time-varying) covariance relationships permit the system to represent and track local anomalies, in contrast with current GP approaches. Most common GP models are stationary, e.g., the covariance relationships are time-invariant. In such cases, information gain is independent of previously collected data, and the optimal solution can always be computed in advance. Information-optimal sampling of a stationary GP time series thus reduces to even spacing, and such models are not appropriate for tracking localized anomalies. Additionally, GP model inference can be computationally expensive.
Basavanhally, Ajay; Viswanath, Satish; Madabhushi, Anant
2015-01-01
Clinical trials increasingly employ medical imaging data in conjunction with supervised classifiers, where the latter require large amounts of training data to accurately model the system. Yet, a classifier selected at the start of the trial based on smaller and more accessible datasets may yield inaccurate and unstable classification performance. In this paper, we aim to address two common concerns in classifier selection for clinical trials: (1) predicting expected classifier performance for large datasets based on error rates calculated from smaller datasets and (2) the selection of appropriate classifiers based on expected performance for larger datasets. We present a framework for comparative evaluation of classifiers using only limited amounts of training data by using random repeated sampling (RRS) in conjunction with a cross-validation sampling strategy. Extrapolated error rates are subsequently validated via comparison with leave-one-out cross-validation performed on a larger dataset. The ability to predict error rates as dataset size increases is demonstrated on both synthetic data as well as three different computational imaging tasks: detecting cancerous image regions in prostate histopathology, differentiating high and low grade cancer in breast histopathology, and detecting cancerous metavoxels in prostate magnetic resonance spectroscopy. For each task, the relationships between 3 distinct classifiers (k-nearest neighbor, naive Bayes, Support Vector Machine) are explored. Further quantitative evaluation in terms of interquartile range (IQR) suggests that our approach consistently yields error rates with lower variability (mean IQRs of 0.0070, 0.0127, and 0.0140) than a traditional RRS approach (mean IQRs of 0.0297, 0.0779, and 0.305) that does not employ cross-validation sampling for all three datasets. PMID:25993029
Chevan, Julia; Haskvitz, Esther M
2010-05-01
Physical therapy practitioners are among the many health care professionals who can counsel their patients to address the public health care concern of physical inactivity. Health care providers who are physically active themselves are more likely to counsel patients on the benefits of activity. The purposes of this study were: (1) to examine the leisure-time physical activity habits of physical therapists, physical therapist assistants, and student physical therapists in the United States using Centers for Disease Control and Prevention and American College of Sports Medicine (CDC-ACSM) recommendations and (2) to compare these habits with those of the general population and other health care professionals. A cross-sectional survey design was used. There were 2 data sources. A random sample of American Physical Therapy Association members completed an online survey that included questions about physical activity habits worded in same manner as the leisure-time activities section of the 2005 National Health Interview Survey (NHIS). The final study sample comprised 1,238 participants: 923 physical therapists, 210 student physical therapists, and 105 physical therapist assistants. The 2005 NHIS public use data files were the source for the same information about the general US population and for a subset of health care professionals. Rates of participation in vigorous and moderate physical activity were analyzed. Physical therapists, physical therapist assistants, and student physical therapists exercised at higher rates than adults and health-diagnosing professionals in the 2005 NHIS. Limitations The study may be limited by sampling and response bias. This study identified that physical therapists, physical therapist assistants, and student physical therapists are meeting CDC-ACSM physical activity guidelines at higher rates than the US adult population and health-diagnosing professionals. These rates exceed the physical activity targets set for adults in Healthy People 2010.
Guo, Yan; Li, Xiaoming; Fang, Xiaoyi; Lin, Xiuyun; Song, Yan; Jiang, Shuling; Stanton, Bonita
2011-01-01
Sample representativeness remains one of the challenges in effective HIV/STD surveillance and prevention targeting MSM worldwide. Although convenience samples are widely used in studies of MSM, previous studies suggested that these samples might not be representative of the broader MSM population. This issue becomes even more critical in many developing countries where needed resources for conducting probability sampling are limited. We examined variations in HIV and Syphilis infections and sociodemographic and behavioral factors among 307 young migrant MSM recruited using four different convenience sampling methods (peer outreach, informal social network, Internet, and venue-based) in Beijing, China in 2009. The participants completed a self-administered survey and provided blood specimens for HIV/STD testing. Among the four MSM samples using different recruitment methods, rates of HIV infections were 5.1%, 5.8%, 7.8%, and 3.4%; rates of Syphilis infection were 21.8%, 36.2%, 11.8%, and 13.8%; rates of inconsistent condom use were 57%, 52%, 58%, and 38%. Significant differences were found in various sociodemographic characteristics (e.g., age, migration history, education, income, places of employment) and risk behaviors (e.g., age at first sex, number of sex partners, involvement in commercial sex, and substance use) among samples recruited by different sampling methods. The results confirmed the challenges of obtaining representative MSM samples and underscored the importance of using multiple sampling methods to reach MSM from diverse backgrounds and in different social segments and to improve the representativeness of the MSM samples when the use of probability sampling approach is not feasible. PMID:21711162
Guo, Yan; Li, Xiaoming; Fang, Xiaoyi; Lin, Xiuyun; Song, Yan; Jiang, Shuling; Stanton, Bonita
2011-11-01
Sample representativeness remains one of the challenges in effective HIV/STD surveillance and prevention targeting men who have sex with men (MSM) worldwide. Although convenience samples are widely used in studies of MSM, previous studies suggested that these samples might not be representative of the broader MSM population. This issue becomes even more critical in many developing countries where needed resources for conducting probability sampling are limited. We examined variations in HIV and Syphilis infections and sociodemographic and behavioral factors among 307 young migrant MSM recruited using four different convenience sampling methods (peer outreach, informal social network, Internet, and venue-based) in Beijing, China in 2009. The participants completed a self-administered survey and provided blood specimens for HIV/STD testing. Among the four MSM samples using different recruitment methods, rates of HIV infections were 5.1%, 5.8%, 7.8%, and 3.4%; rates of Syphilis infection were 21.8%, 36.2%, 11.8%, and 13.8%; and rates of inconsistent condom use were 57%, 52%, 58%, and 38%. Significant differences were found in various sociodemographic characteristics (e.g., age, migration history, education, income, and places of employment) and risk behaviors (e.g., age at first sex, number of sex partners, involvement in commercial sex, and substance use) among samples recruited by different sampling methods. The results confirmed the challenges of obtaining representative MSM samples and underscored the importance of using multiple sampling methods to reach MSM from diverse backgrounds and in different social segments and to improve the representativeness of the MSM samples when the use of probability sampling approach is not feasible.
Crowley, Stephanie J.; Suh, Christina; Molina, Thomas A.; Fogg, Louis F.; Sharkey, Katherine M.; Carskadon, Mary A.
2016-01-01
Objective/Background Circadian rhythm sleep-wake disorders often manifest during the adolescent years. Measurement of circadian phase such as the Dim Light Melatonin Onset (DLMO) improves diagnosis and treatment of these disorders, but financial and time costs limit the use of DLMO phase assessments in clinic. The current analysis aims to inform a cost-effective and efficient protocol to measure the DLMO in older adolescents by reducing the number of samples and total sampling duration. Patients/Methods A total of 66 healthy adolescents (26 males) aged 14.8 to 17.8 years participated in a study in which sleep was fixed for one week before they came to the laboratory for saliva collection in dim light (<20 lux). Two partial 6-h salivary melatonin profiles were derived for each participant. Both profiles began 5 h before bedtime and ended 1 h after bedtime, but one profile was derived from samples taken every 30 mins (13 samples) and the other from samples taken every 60 mins (7 samples). Three standard thresholds (first 3 melatonin values mean + 2 SDs, 3 pg/mL, and 4 pg/mL) were used to compute the DLMO. Agreement between DLMOs derived from 30-min and 60-min sampling rates was determined using a Bland-Altman analysis; agreement between sampling rate DLMOs was defined as ± 1 h. Results and Conclusions Within a 6-h sampling window, 60-min sampling provided DLMO estimates that were within ± 1 h of DLMO from 30-min sampling, but only when an absolute threshold (3 pg/mL or 4 pg/mL) was used to compute the DLMO. Future analyses should be extended to include adolescents with circadian rhythm sleep-wake disorders. PMID:27318227
Ballard, Elizabeth D; Yarrington, Julia S; Farmer, Cristan A; Lener, Marc S; Kadriu, Bashkim; Lally, Níall; Williams, Deonte; Machado-Vieira, Rodrigo; Niciu, Mark J; Park, Lawrence; Zarate, Carlos A
2018-04-15
Due to the heterogeneity of depressive symptoms-which can include depressed mood, anhedonia, negative cognitive biases, and altered activity levels-researchers often use a combination of depression rating scales to assess symptoms. This study sought to identify unidimensional constructs measured across rating scales for depression and to evaluate these constructs across clinical trials of a rapid-acting antidepressant (ketamine). Exploratory factor analysis (EFA) was conducted on baseline ratings from the Beck Depression Inventory (BDI), the Hamilton Depression Rating Scale (HAM-D), the Montgomery-Asberg Depression Rating Scale (MADRS), and the Snaith-Hamilton Pleasure Rating Scale (SHAPS). Inpatients with major depressive disorder (n = 76) or bipolar depression (n = 43) were participating in clinical ketamine trials. The trajectories of the resulting unidimensional scores were evaluated in 41 subjects with bipolar depression who participated in clinical ketamine trials. The best solution, which exhibited excellent fit to the data, comprised eight factors: Depressed Mood, Tension, Negative Cognition, Impaired Sleep, Suicidal Thoughts, Reduced Appetite, Anhedonia, and Amotivation. Various response patterns were observed across the clinical trial data, both in treatment effect (ketamine versus placebo) and in degree of placebo response, suggesting that use of these unidimensional constructs may reveal patterns not observed with traditional scoring of individual instruments. Limitations include: 1) small sample (and related inability to confirm measurement invariance); 2) absence of an independent sample for confirmation of factor structure; and 3) the treatment-resistant nature of the population, which may limit generalizability. The empirical identification of unidimensional constructs creates more refined scores that may elucidate the connection between specific symptoms and underlying pathophysiology. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Rössler, Erik; Mattea, Carlos; Stapf, Siegfried
2015-02-01
Low field Nuclear Magnetic Resonance increases the contrast of the longitudinal relaxation rate in many biological tissues; one prominent example is hyaline articular cartilage. In order to take advantage of this increased contrast and to profile the depth-dependent variations, high resolution parameter measurements are carried out which can be of critical importance in an early diagnosis of cartilage diseases such as osteoarthritis. However, the maximum achievable spatial resolution of parameter profiles is limited by factors such as sensor geometry, sample curvature, and diffusion limitation. In this work, we report on high-resolution single-sided NMR scanner measurements with a commercial device, and quantify these limitations. The highest achievable spatial resolution on the used profiler, and the lateral dimension of the sensitive volume were determined. Since articular cartilage samples are usually bent, we also focus on averaging effects inside the horizontally aligned sensitive volume and their impact on the relaxation profiles. Taking these critical parameters into consideration, depth-dependent relaxation time profiles with the maximum achievable vertical resolution of 20 μm are discussed, and are correlated with diffusion coefficient profiles in hyaline articular cartilage in order to reconstruct T2 maps from the diffusion-weighted CPMG decays of apparent relaxation rates.
Scale and Sampling Effects on Floristic Quality
2016-01-01
Floristic Quality Assessment (FQA) is increasingly influential for making land management decisions, for directing conservation policy, and for research. But, the basic ecological properties and limitations of its metrics are ill defined and not well understood–especially those related to sample methods and scale. Nested plot data from a remnant tallgrass prairie sampled annually over a 12-year period, were used to investigate FQA properties associated with species detection rates, species misidentification rates, sample year, and sample grain/area. Plot size had no apparent effect on Mean C (an area’s average Floristic Quality level), nor did species detection levels above 65% detection. Simulated species misidentifications only affected Mean C values at greater than 10% in large plots, when the replaced species were randomly drawn from the broader county-wide species pool. Finally, FQA values were stable over the 12-year study, meaning that there was no evidence that the metrics exhibit year effects. The FQA metric Mean C is demonstrated to be robust to varied sample methodologies related to sample intensity (plot size, species detection rate), as well as sample year. These results will make FQA measures even more appealing for informing land-use decisions, policy, and research for two reasons: 1) The sampling effort needed to generate accurate and consistent site assessments with FQA measures is shown to be far lower than what has previously been assumed, and 2) the stable properties and consistent performance of metrics with respect to sample methods will allow for a remarkable level of comparability of FQA values from different sites and datasets compared to other commonly used ecological metrics. PMID:27489959
Yang, Heewon; Kim, Hyoji; Shin, Junho; Kim, Chur; Choi, Sun Young; Kim, Guang-Hoon; Rotermund, Fabian; Kim, Jungwon
2014-01-01
We show that a 1.13 GHz repetition rate optical pulse train with 0.70 fs high-frequency timing jitter (integration bandwidth of 17.5 kHz-10 MHz, where the measurement instrument-limited noise floor contributes 0.41 fs in 10 MHz bandwidth) can be directly generated from a free-running, single-mode diode-pumped Yb:KYW laser mode-locked by single-wall carbon nanotube-coated mirrors. To our knowledge, this is the lowest-timing-jitter optical pulse train with gigahertz repetition rate ever measured. If this pulse train is used for direct sampling of 565 MHz signals (Nyquist frequency of the pulse train), the jitter level demonstrated would correspond to the projected effective-number-of-bit of 17.8, which is much higher than the thermal noise limit of 50 Ω load resistance (~14 bits).
Witt, Emitt C; Wronkiewicz, David J; Shi, Honglan
2013-01-01
Fugitive road dust collection for chemical analysis and interpretation has been limited by the quantity and representativeness of samples. Traditional methods of fugitive dust collection generally focus on point-collections that limit data interpretation to a small area or require the investigator to make gross assumptions about the origin of the sample collected. These collection methods often produce a limited quantity of sample that may hinder efforts to characterize the samples by multiple geochemical techniques, preserve a reference archive, and provide a spatially integrated characterization of the road dust health hazard. To achieve a "better sampling" for fugitive road dust studies, a cyclonic fugitive dust (CFD) sampler was constructed and tested. Through repeated and identical sample collection routes at two collection heights (50.8 and 88.9 cm above the road surface), the products of the CFD sampler were characterized using particle size and chemical analysis. The average particle size collected by the cyclone was 17.9 μm, whereas particles collected by a secondary filter were 0.625 μm. No significant difference was observed between the two sample heights tested and duplicates collected at the same height; however, greater sample quantity was achieved at 50.8 cm above the road surface than at 88.9 cm. The cyclone effectively removed 94% of the particles >1 μm, which substantially reduced the loading on the secondary filter used to collect the finer particles; therefore, suction is maintained for longer periods of time, allowing for an average sample collection rate of about 2 g mi. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
NASA Astrophysics Data System (ADS)
Cui, Sheng; Jin, Shang; Xia, Wenjuan; Ke, Changjian; Liu, Deming
2015-11-01
Symbol rate identification (SRI) based on asynchronous delayed sampling is accurate, cost-effective and robust to impairments. For on-off keying (OOK) signals the symbol rate can be derived from the periodicity of the second-order autocorrelation function (ACF2) of the delay tap samples. But it is found that when applied this method to advanced modulation format signals with auxiliary amplitude modulation (AAM), incorrect results may be produced because AAM has significant impact on ACF2 periodicity, which makes the symbol period harder or even unable to be correctly identified. In this paper it is demonstrated that for these signals the first order autocorrelation function (ACF1) has stronger periodicity and can be used to replace ACF2 to produce more accurate and robust results. Utilizing the characteristics of the ACFs, an improved SRI method is proposed to accommodate both OOK and advanced modulation formant signals in a transparent manner. Furthermore it is proposed that by minimizing the peak to average ratio (PAPR) of the delay tap samples with an additional tunable dispersion compensator (TDC) the limited dispersion tolerance can be expanded to desired values.
Pitzer, Lindsay; Armour, Cherie; Karlamangla, Arun; Ryff, Carol D.; Mroczek, Daniel K.
2012-01-01
Objectives. Personality traits predict numerous health outcomes, but previous studies have rarely used personality change to predict health. Methods. The current investigation utilized a large national sample of 3,990 participants from the Midlife in the U.S. study (MIDUS) to examine if both personality trait level and personality change longitudinally predict 3 different health outcomes (i.e., self-rated physical health, self-reported blood pressure, and number of days limited at work or home due to physical health reasons) over a 10-year span. Results. Each of the Big Five traits, except openness, predicted self-rated health. Change in agreeableness, conscientiousness, and extraversion also predicted self-rated health. Trait levels of conscientiousness and neuroticism level predicted self-reported blood pressure. All trait levels except agreeableness predicted number of work days limited. Only change in conscientiousness predicted the number of work days limited. Discussion. Findings demonstrate that a full understanding of the link between personality and health requires consideration of trait change as well as trait level. PMID:21765062
One GigaSample Per Second Data Acquisition using Available Gate Array Technology
NASA Technical Reports Server (NTRS)
Wagner, K.W.
1999-01-01
A new National Aeronautics and Space Administration instrument forced demanding requirements upon its altimeter digitizer system. Eight-bit data would be generated at a rate of one billion samples per second. NASA had never before attempted to capture such high-speed data in the radiation, low-power, no-convective-cooling, limited-board-area environment of space. This presentation describes how the gate array technology available at the time of the design was used to implement this one gigasample per second data acquisition system
Chemical quality of precipitation at Greenville, Maine
Smath, J.A.; Potter, T.L.
1987-01-01
Weekly composite precipitation samples were collected at a rural site located in Greenville, Maine for analysis of trace metals and organic compounds. Samples collected during February 1982, through May 1984, were analyzed for cadmium, chromium, copper, lead, mercury, nickel, and zinc and during February 1982, through March 1983, for chlorinated hydrocarbon pesticides, pthalate ester plasticizers, and polychlorinated biphenyls. Deposition rates were computed. Data reported by the NADP (National Atmospheric Deposition Program) was used to evaluate the general chemical quality of the precipitation. The precipitation had relatively high concentrations of hydrogen ions, sulfate, and nitrate, compared to other constituents. Of the trace metals included for analysis, only copper, lead, and zinc were consistently detected. Lead concentrations exceeded the U.S. EPA recommended limit for domestic water supply in three samples. High deposition rates for some of the metals were episodic. Alpha-hexachlorocyclohexane was the only organic compound that was consistently detected (maximum 120 nanograms/L). None of the other organic compounds were detected in any of the samples. (Author 's abstract)
NASA Astrophysics Data System (ADS)
Lopeandía, A. F.; Cerdó, L. l.; Clavaguera-Mora, M. T.; Arana, Leonel R.; Jensen, K. F.; Muñoz, F. J.; Rodríguez-Viejo, J.
2005-06-01
We have designed and developed a sensitive scanning calorimeter for use with microgram or submicrogram, thin film, or powder samples. Semiconductor processing techniques are used to fabricate membrane based microreactors with a small heat capacity of the addenda, 120nJ/K at room temperature. At heating rates below 10K/s the heat released or absorbed by the sample during a given transformation is compensated through a resistive Pt heater by a digital controller so that the calorimeter works as a power compensated device. Its use and dynamic sensitivity is demonstrated by analyzing the melting behavior of thin films of indium and high density polyethylene. Melting enthalpies in the range of 40-250μJ for sample masses on the order of 1.5μg have been measured with accuracy better than 5% at heating rates ˜0.2K/s. The signal-to-noise ratio, limited by the electronic setup, is 200nW.
Farhangdoust, S; Zamanian, A; Yasaei, M; Khorami, M
2013-01-01
The design and fabrication of macroporous hydroxyapatite scaffolds, which could overcome current bone tissue engineering limitations, have been considered in recent years. In the current study, controlled unidirectional freeze-casting at different cooling rates was investigated. In the first step, different slurries with initial hydroxyapatite concentrations of 7-37.5 vol.% were prepared. In the next step, different cooling rates from 2 to 14 °C/min were applied to synthesize the porous scaffold. Additionally, a sintering temperature of 1350 °C was chosen as an optimum temperature. Finally, the phase composition (by XRD), microstructure (by SEM), mechanical characteristics, and the porosity of sintered samples were assessed. The porosity of the sintered samples was in a range of 45-87% and the compressive strengths varied from 0.4 MPa to 60 MPa. The mechanical strength of the scaffolds increased as a function of initial concentration, cooling rate, and sintering temperature. With regards to mechanical strength and pore size, the samples with the initial concentration and the cooling rate of 15 vol.% and 5 °C/min, respectively, showed better results. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaidi, B.R.; Murakami, Y.; Alexander, M.
1988-12-01
Corynebacterium sp. added to lake water rapidly mineralized 100 ..mu..g and 1.0 mg of p-nitrophenol (PNP)/L but acted very slowly on the substrate present at 26 ..mu..g/L. The rate and extent of mineralization of the lowest PNP concentration in Beebe Lake water varied according to the time the sample was taken and were directly related to rainfall, and presumably runoff, in the watershed. The addition of high concentrations of inorganic P or N to water samples collected after a drought period, during which mineralization by the bacterium was slow, enhanced PNP decomposition. Mineralization in Cayuga Lake water was increased slightlymore » by 10 mg of K/sub 2/HPO/sub 4//L, but the enhancement was marked by 100 mg/L. The stimulation was a response to P and K. Glucose stimulated PNP mineralization in samples from Beebe and Cayuga Lakes, and K/sub 2/HOP/sub 4/ further increased the rate and extent of the transformation. The addition of either of two eucaryotic inhibitors increased the rate of Corynebacterium sp. growth in lake water amended with 26 ..mu..g of PNP/L but decreased the rate of mineralization.« less
Al Lawati, Haider A J; Al Mughairy, Baqia; Al Lawati, Iman; Suliman, FakhrEldin O
2018-04-30
A novel mixing approach was utilized with a highly sensitive chemiluminescence (CL) method to determine the total phenolic content (TPC) in honey samples using an acidic potassium permanganate-formaldehyde system. The mixing approach was based on exploiting the mixing efficiency of nanodroplets generated in a microfluidic platform. Careful optimization of the instrument setup and various experimental conditions were employed to obtain excellent sensitivity. The mixing efficiency of the droplets was compared with the CL signal intensity obtained using the common serpentine chip design, with both approaches using at a total flow rate of 15 μl min -1 ; the results showed that the nanodroplets provided 600% higher CL signal intensity at this low flow rate. Using the optimum conditions, calibration equations, limits of detection (LOD) and limits of quantification (LOQ) for gallic acid (GA), caffeic acid (CA), kaempferol (KAM), quercetin (QRC) and catechin (CAT) were obtained. The LOD ranged from 6.2 ppb for CA to 11.0 ppb for QRC. Finally, the method was applied for the determination of TPC in several local and commercial honey samples. Copyright © 2018 John Wiley & Sons, Ltd.
Slater, Graham J; Harmon, Luke J; Wegmann, Daniel; Joyce, Paul; Revell, Liam J; Alfaro, Michael E
2012-03-01
In recent years, a suite of methods has been developed to fit multiple rate models to phylogenetic comparative data. However, most methods have limited utility at broad phylogenetic scales because they typically require complete sampling of both the tree and the associated phenotypic data. Here, we develop and implement a new, tree-based method called MECCA (Modeling Evolution of Continuous Characters using ABC) that uses a hybrid likelihood/approximate Bayesian computation (ABC)-Markov-Chain Monte Carlo approach to simultaneously infer rates of diversification and trait evolution from incompletely sampled phylogenies and trait data. We demonstrate via simulation that MECCA has considerable power to choose among single versus multiple evolutionary rate models, and thus can be used to test hypotheses about changes in the rate of trait evolution across an incomplete tree of life. We finally apply MECCA to an empirical example of body size evolution in carnivores, and show that there is no evidence for an elevated rate of body size evolution in the pinnipeds relative to terrestrial carnivores. ABC approaches can provide a useful alternative set of tools for future macroevolutionary studies where likelihood-dependent approaches are lacking. © 2011 The Author(s). Evolution© 2011 The Society for the Study of Evolution.
Petersen, Jördis; Pröfrock, Daniel; Paschke, Albrecht; Broekaert, Jose A C; Prange, Andreas
2015-10-01
Little knowledge is available about water concentrations of rare earth elements (REEs) in the marine environment. The direct measurement of REEs in coastal waters is a challenging task due to their ultra-low concentrations as well as the high salt content in the water samples. To quantify these elements at environmental concentrations (pg L(-1) to low ng L(-1)) in coastal waters, current analytical techniques are generally expensive and time consuming, and require complex chemical preconcentration procedures. Therefore, an integrative passive sampler was tested as a more economic alternative sampling approach for REE analysis. We used a Chemcatcher-Metal passive sampler consisting of a 3M Empore Chelating Disk as the receiving phase, as well as a cellulose acetate membrane as the diffusion-limiting layer. The effect of water turbulence and temperature on the uptake rates of REEs was analyzed during 14-day calibration experiments by a flow-through exposure tank system. The sampling rates were in the range of 0.42 mL h(-1) (13 °C; 0.25 m s(-1)) to 4.01 mL h(-1) (13 °C; 1 m s(-1)). Similar results were obtained for the different REEs under investigation. The water turbulence was the most important influence on uptake. The uptake rates were appropriate to ascertain time-weighted average concentrations of REEs during a field experiment in the Elbe Estuary near Cuxhaven Harbor (exposure time 4 weeks). REE concentrations were determined to be in the range 0.2 to 13.8 ng L(-1), where the highest concentrations were found for neodymium and samarium. In comparison, most of the spot samples measured along the Chemcatcher samples had REE concentrations below the limit of detection, in particular due to necessary dilution to minimize the analytical problems that arise with the high salt content in marine water samples. This study was among the first efforts to measure REE levels in the field using a passive sampling approach. Our results suggest that passive samplers could be an effective tool to monitor ultra-trace concentrations of REEs in coastal waters with high salt content.
Setting Age Limits for TT-OSL Dating - the Local Effect
NASA Astrophysics Data System (ADS)
Faershtein, G.; Porat, N.; Guralnik, B.; Matmon, A.
2017-12-01
Luminescence dating techniques, especially Optically Stimulated Luminescence (OSL) on quartz, are widely used for dating middle Pleistocene to late Holocene sediments from different geological settings. The dating limit of a particular luminescence method depends on signal saturation and its thermal stability. The OSL signal saturates at doses of 200 Gy, equivalent to ages of 150-300 ka. Thermally Transferred OSL (TT-OSL) is a developmental technique, which potentially extends the luminescence dating range up to 1000 ka. For the Chinese Loess Plateau, experiments have shown that the natural TT-OSL signal saturates at 2200 Gy (Chapot et al., 2016). Regarding thermal stability, different studies report a wide range of estimates (0.24-861 Ma), suggesting that the thermal lifetime of TT-OSL is (i) currently poorly constrained, and (ii) may vary both by sample and region. Here, we investigated the dating limit of TT-OSL, using quartz of Nilotic origin (Israel), obtained from two sediment sections of similar depth but different dose rates. Natural dose response curves (DRC) of the TT-OSL signal were constructed for each section separately. In both sections, luminescence intensity grows sub-linearly up to 450 Gy, beyond which it remains constant with depth. The absence of equivalent doses (De) over 600 Gy, at both sections (as well as elsewhere regionally), suggest that TT-OSL signal saturation may be an intrinsic property, related to quartz provenance, and independent of the specific ionizing dose rate at each section. The thermal stability of TT-OSL was investigated on a modern sample from one section, using a combination of analytical techniques (varying heating rates, and isothermal storage). The obtained TT-OSL lifetimes range between 105-107 ka, and reinforce a significant inter sample variability. A synthesis of our results suggests that TT-OSL ages of Nilotic quartz derived from De values over 450 Gy, are likely underestimates, and should be treated as minimum ages. The limiting value of 600 Gy for local quartz TT-OSL is likely representative of a steady-state between TT-OSL trap filling due to ionizing radiation, and the concurrent thermal empting of these traps.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sistine, Angela Van; Salzer, John J.; Janowiecki, Steven
2016-06-10
The ALFALFA H α survey utilizes a large sample of H i-selected galaxies from the ALFALFA survey to study star formation (SF) in the local universe. ALFALFA H α contains 1555 galaxies with distances between ∼20 and ∼100 Mpc. We have obtained continuum-subtracted narrowband H α images and broadband R images for each galaxy, creating one of the largest homogeneous sets of H α images ever assembled. Our procedures were designed to minimize the uncertainties related to the calculation of the local SF rate density (SFRD). The galaxy sample we constructed is as close to volume-limited as possible, is amore » robust statistical sample, and spans a wide range of galaxy environments. In this paper, we discuss the properties of our Fall sample of 565 galaxies, our procedure for deriving individual galaxy SF rates, and our method for calculating the local SFRD. We present a preliminary value of log(SFRD[ M {sub ⊙} yr{sup −1} Mpc{sup −3}]) = −1.747 ± 0.018 (random) ±0.05 (systematic) based on the 565 galaxies in our Fall sub-sample. Compared to the weighted average of SFRD values around z ≈ 2, our local value indicates a drop in the global SFRD of a factor of 10.2 over that lookback time.« less
Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael
2011-04-01
The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.
Melting of superheated molecular crystals
NASA Astrophysics Data System (ADS)
Cubeta, Ulyana; Bhattacharya, Deepanjan; Sadtchenko, Vlad
2017-07-01
Melting dynamics of micrometer scale, polycrystalline samples of isobutane, dimethyl ether, methyl benzene, and 2-propanol were investigated by fast scanning calorimetry. When films are superheated with rates in excess of 105 K s-1, the melting process follows zero-order, Arrhenius-like kinetics until approximately half of the sample has transformed. Such kinetics strongly imply that melting progresses into the bulk via a rapidly moving solid-liquid interface that is likely to originate at the sample's surface. Remarkably, the apparent activation energies for the phase transformation are large; all exceed the enthalpy of vaporization of each compound and some exceed it by an order of magnitude. In fact, we find that the crystalline melting kinetics are comparable to the kinetics of dielectric α-relaxation in deeply supercooled liquids. Based on these observations, we conclude that the rate of non-isothermal melting for superheated, low-molecular-weight crystals is limited by constituent diffusion into an abnormally dense, glass-like, non-crystalline phase.
The search for organic substances and inorganic volatile compounds in the surface of Mars
NASA Technical Reports Server (NTRS)
Biemann, K.; Oro, J.; Toulmin, P., III; Orgel, L. E.; Nier, A. O.; Anderson, D. M.; Flory, D.; Diaz, A. V.; Rushneck, D. R.; Simmonds, P. G.
1977-01-01
A total of four Martian samples, one surface and one subsurface sample at each of the two Viking landing sites, Chryse Planitia and Utopia Planitia, have been analyzed for organic compounds by a gas chromatograph-mass spectrometer. In none of these experiments could organic material of Martian origin be detected at detection limits generally of the order of parts per billion and for a few substances closer to parts per million. The evolution of water and carbon dioxide, but not of other inorganic gases, was observed upon heating the sample to temperatures of up to 500 C. The absence of organic compounds seems to preclude their production on the planet at rates that exceed the rate of their destruction. It also makes it unlikely that living systems that behave in a manner similar to terrestrial biota exist, at least at the two Viking landing sites.
Design of a Sample Recovery Assembly for Magnetic Ramp-Wave Loading
NASA Astrophysics Data System (ADS)
Chantrenne, S.; Wise, J. L.; Asay, J. R.; Kipp, M. E.; Hall, C. A.
2009-06-01
Characterization of material behavior under dynamic loading requires studies at strain rates ranging from quasi-static to the limiting values of shock compression. For completeness, these studies involve complementary time-resolved data, which define the mechanical constitutive properties, and microstructural data, which reveal physical mechanisms underlying the observed mechanical response. Well-preserved specimens must be recovered for microstructural investigations. Magnetically generated ramp waves produce strain rates lower than those associated with shock waves, but recovery methods have been lacking for this type of loading. We adapted existing shock recovery techniques for application to magnetic ramp loading using 2-D and 3-D ALEGRA MHD code calculations to optimize the recovery design for mitigation of undesired late-time processing of the sample due to edge effects and secondary stress waves. To assess the validity of our simulations, measurements of sample deformation were compared to wavecode predictions.
Price-Haywood, Eboni G; Harden-Barrios, Jewel; Cooper, Lisa A
2014-08-01
We designed a continuing medical education (CME) program to teach primary care physicians (PCP) how to engage in cancer risk communication and shared decision making with patients who have limited health literacy (HL). We evaluated whether training PCPs, in addition to audit-feedback, improves their communication behaviors and increases cancer screening among patients with limited HL to a greater extent than only providing clinical performance feedback. Four-year cluster randomized controlled trial. Eighteen PCPs and 168 patients with limited HL who were overdue for colorectal/breast/cervical cancer screening. Communication intervention PCPs received skills training that included standardized patient (SP) feedback on counseling behaviors. All PCPs underwent chart audits of patients' screening status semiannually up to 24 months and received two annual performance feedback reports. PCPs experienced three unannounced SP encounters during which SPs rated PCP communication behaviors. We examined between-group differences in changes in SP ratings and patient knowledge of cancer screening guidelines over 12 months; and changes in patient cancer screening rates over 24 months. There were no group differences in SP ratings of physician communication at baseline. At follow-up, communication intervention PCPs were rated higher in general communication about cancer risks and shared decision making related to colorectal cancer screening compared to PCPs who only received performance feedback. Screening rates increased among patients of PCPs in both groups; however, there were no between-group differences in screening rates except for mammography. The communication intervention did not improve patient cancer screening knowledge. Compared to audit and feedback alone, including PCP communication training increases PCP patient-centered counseling behaviors, but not cancer screening among patients with limited HL. Larger studies must be conducted to determine whether lack of changes in cancer screening were due to clinic/patient sample size versus ineffectiveness of communication training to change outcomes.
Formulation of steam-methane reforming rate in Ni-YSZ porous anode of solid oxide fuel cells
NASA Astrophysics Data System (ADS)
Sugihara, Shinichi; Kawamura, Yusuke; Iwai, Hiroshi
2018-02-01
The steam-methane reforming reaction on a Ni-YSZ (yttria-stabilized zirconia) cermet was experimentally investigated under atmospheric pressure and in the temperature range from 650 to 750 °C. We examined the effects of the partial pressures of methane and steam in the supply gas on the reaction rate. The experiments were conducted with a low Ni contained Ni-YSZ cermet sheet of thickness 0.1 mm. Its porous microstructure and accompanied parameters were quantified using the FIB-SEM (focused ion beam scanning electron microscopy) technique. A power-law-type rate equation incorporating the reaction-rate-limiting conditions was obtained on the basis of the unit surface area of the Ni-pore contact surface in the cermet. The kinetics indicated a strong positive dependence on the methane partial pressure and a negative dependence on the steam partial pressure. The obtained rate equation successfully reproduced the experimental results for Ni-YSZ samples having different microstructures in the case of low methane consumption. The equation also reproduced the limiting-reaction behaviours at different temperatures.
Alvarez, Luis H; Meza-Escalante, Edna R; Gortáres-Moroyoqui, Pablo; Morales, Luz; Rosas, Krystal; García-Reyes, Bernardo; García-González, Alicone
2016-12-01
The rate-limiting step of azo dye decolorization was elucidated by exploring the microbial reduction of a model quinone and the chemical decolorization by previously reduced quinone at different salinity conditions (2-8%). Microbial experiments were performed in batch with a marine consortium. The decolorization of Direct Blue 71 (DB71) by the marine consortium at 2% salinity, mediated with anthraquinone-2,6-disulfonate (AQDS), showed the highest rate of decolorization as compared with those obtained with riboflavin, and two samples of humic acids. Moreover, the incubations at different salinity conditions (0-8%) performed with AQDS showed that the highest rate of decolorization of DB71 by the marine consortium occurred at 2% and 4% salinity. In addition, the highest microbial reduction rate of AQDS occurred in incubations at 0%, 2%, and 4% of salinity. The chemical reduction of DB71 by reduced AQDS occurred in two stages and proceeded faster at 4% and 6% salinity. The results indicate that the rate-limiting step during azo decolorization was the microbial reduction of AQDS. Copyright © 2016 Elsevier Ltd. All rights reserved.
Benavides, Julio A; Cross, Paul C; Luikart, Gordon; Creel, Scott
2014-01-01
Cross-species transmission (CST) of bacterial pathogens has major implications for human health, livestock, and wildlife management because it determines whether control actions in one species may have subsequent effects on other potential host species. The study of bacterial transmission has benefitted from methods measuring two types of genetic variation: variable number of tandem repeats (VNTRs) and single nucleotide polymorphisms (SNPs). However, it is unclear whether these data can distinguish between different epidemiological scenarios. We used a simulation model with two host species and known transmission rates (within and between species) to evaluate the utility of these markers for inferring CST. We found that CST estimates are biased for a wide range of parameters when based on VNTRs and a most parsimonious reconstructed phylogeny. However, estimations of CST rates lower than 5% can be achieved with relatively low bias using as low as 250 SNPs. CST estimates are sensitive to several parameters, including the number of mutations accumulated since introduction, stochasticity, the genetic difference of strains introduced, and the sampling effort. Our results suggest that, even with whole-genome sequences, unbiased estimates of CST will be difficult when sampling is limited, mutation rates are low, or for pathogens that were recently introduced. PMID:25469159
Julio Andre, Benavides; Cross, Paul C.; Luikart, Gordon; Scott, Creel
2014-01-01
Cross-species transmission (CST) of bacterial pathogens has major implications for human health, livestock, and wildlife management because it determines whether control actions in one species may have subsequent effects on other potential host species. The study of bacterial transmission has benefitted from methods measuring two types of genetic variation: variable number of tandem repeats (VNTRs) and single nucleotide polymorphisms (SNPs). However, it is unclear whether these data can distinguish between different epidemiological scenarios. We used a simulation model with two host species and known transmission rates (within and between species) to evaluate the utility of these markers for inferring CST. We found that CST estimates are biased for a wide range of parameters when based on VNTRs and a most parsimonious reconstructed phylogeny. However, estimations of CST rates lower than 5% can be achieved with relatively low bias using as low as 250 SNPs. CST estimates are sensitive to several parameters, including the number of mutations accumulated since introduction, stochasticity, the genetic difference of strains introduced, and the sampling effort. Our results suggest that, even with whole-genome sequences, unbiased estimates of CST will be difficult when sampling is limited, mutation rates are low, or for pathogens that were recently introduced.
Examining the Relations between Psychopathology and Social Skills in Children with ASD
ERIC Educational Resources Information Center
Rodriguez, Geovanna R.
2017-01-01
This study examined the relations between child internalizing behavior problems and social competence in a sample of young children (N = 166) with autism spectrum disorders (ASD) as they transitioned to early schooling. Previous literature suggested higher rates of comorbid psychopathology in this population of children; however, a limited number…
Widefield compressive multiphoton microscopy.
Alemohammad, Milad; Shin, Jaewook; Tran, Dung N; Stroud, Jasper R; Chin, Sang Peter; Tran, Trac D; Foster, Mark A
2018-06-15
A single-pixel compressively sensed architecture is exploited to simultaneously achieve a 10× reduction in acquired data compared with the Nyquist rate, while alleviating limitations faced by conventional widefield temporal focusing microscopes due to scattering of the fluorescence signal. Additionally, we demonstrate an adaptive sampling scheme that further improves the compression and speed of our approach.
Parental Characteristics and Resiliency in Identification Rates for Special Education
ERIC Educational Resources Information Center
Anderson, Jeffrey A.; Howland, Allison A.; McCoach, D. Betsy
2015-01-01
Even with increased risks, many children demonstrate resiliency and avoid being labeled for special education; however, research on risk and resilience has been problematic because of inadequate statistical models, limitations of available data, and the exclusion of key protective factors. This study used a national sample to examine the influence…
Uchida, Y.; Takada, E.; Fujisaki, A.; Isobe, M.; Shinohara, K.; Tomita, H.; Kawarabayashi, J.; Iguchi, T.
2014-01-01
Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was applied using the EM algorithm and k-means algorithm. PMID:25430297
A look at motion in the frequency domain
NASA Technical Reports Server (NTRS)
Watson, A. B.; Ahumada, A. J., Jr.
1983-01-01
A moving image can be specified by a contrast distribution, c(x,y,t), over the dimensions of space x,y, and time t. Alternatively, it can be specified by the distribution C(u,v,w) over spatial frequency u,v and temporal frequency w. The frequency representation of a moving image is shown to have a characteristic form. This permits two useful observations. The first is that the apparent smoothness of time-sampled moving images (apparent motion) can be explained by the filtering action of the human visual system. This leads to the following formula for the required update rate for time-sampled displays. W(c)=W(l)+ru(l) where w(c) is the required update rate in Hz, W(l) is the limit of human temporal resolution in Hz, r is the velocity of the moving image in degrees/sec, and u(l) is the limit of human spatial resolution in cycles/deg. The second observation is that it is possible to construct a linear sensor that responds to images moving in a particular direction. The sensor is derived and its properties are discussed.
Fukuda, Jun; Iwura, Takafumi; Yanagihara, Shigehiro; Kano, Kenji
2014-10-01
Hollow-fiber-flow field-flow fractionation (HF5) separates protein molecules on the basis of the difference in the diffusion coefficient, and can evaluate the aggregation ratio of proteins. However, HF5 is still a minor technique because information on the separation conditions is limited. We examined in detail the effect of different settings, including the main-flow rate, the cross-flow rate, the focus point, the injection amount, and the ionic strength of the mobile phase, on fractographic characteristics. On the basis of the results, we proposed optimized conditions of the HF5 method for quantification of monoclonal antibody in sample solutions. The HF5 method was qualified regarding the precision, accuracy, linearity of the main peak, and quantitation limit. In addition, the HF5 method was applied to non-heated Mab A and heat-induced-antibody-aggregate-containing samples to evaluate the aggregation ratio and the distribution extent. The separation performance was comparable with or better than that of conventional methods including analytical ultracentrifugation-sedimentation velocity and asymmetric-flow field-flow fractionation.
Frizzarin, Rejane M; Maya, Fernando; Estela, José M; Cerdà, Víctor
2016-12-01
A novel fully-automated magnetic stirring-assisted lab-in-syringe analytical procedure has been developed for the fast and efficient dispersive liquid-liquid microextraction (DLLME) of caffeine in coffee beverages. The procedure is based on the microextraction of caffeine with a minute amount of dichloromethane, isolating caffeine from the sample matrix with no further sample pretreatment. Selection of the relevant extraction parameters such as the dispersive solvent, proportion of aqueous/organic phase, pH and flow rates have been carefully evaluated. Caffeine quantification was linear from 2 to 75mgL(-1), with detection and quantification limits of 0.46mgL(-1) and 1.54mgL(-1), respectively. A coefficient of variation (n=8; 5mgL(-1)) of a 2.1% and a sampling rate of 16h(-1), were obtained. The procedure was satisfactorily applied to the determination of caffeine in brewed, instant and decaf coffee samples, being the results for the sample analysis validated using high-performance liquid chromatography. Copyright © 2016 Elsevier Ltd. All rights reserved.
Optimizing ultrafast illumination for multiphoton-excited fluorescence imaging
Stoltzfus, Caleb R.; Rebane, Aleksander
2016-01-01
We study the optimal conditions for high throughput two-photon excited fluorescence (2PEF) and three-photon excited fluorescence (3PEF) imaging using femtosecond lasers. We derive relations that allow maximization of the rate of imaging depending on the average power, pulse repetition rate, and noise characteristics of the laser, as well as on the size and structure of the sample. We perform our analysis using ~100 MHz, ~1 MHz and 1 kHz pulse rates and using both a tightly-focused illumination beam with diffraction-limited image resolution, as well loosely focused illumination with a relatively low image resolution, where the latter utilizes separate illumination and fluorescence detection beam paths. Our theoretical estimates agree with the experiments, which makes our approach especially useful for optimizing high throughput imaging of large samples with a field-of-view up to 10x10 cm2. PMID:27231620
Leahy, Joseph G.; Somerville, Charles C.; Cunningham, Kelly A.; Adamantiades, Grammenos A.; Byrd, Jeffrey J.; Colwell, Rita R.
1990-01-01
Rates of degradation of radiolabeled hydrocarbons and incidence of bacterial plasmid DNA were investigated in sediment samples collected from the Campeche Bank, Gulf of Mexico, site of an offshore oil field containing several petroleum platforms. Overall rates of mineralization of [14C]hexadecane and [14C]phenanthrene measured for sediments were negligible; <1% of the substrate was converted to CO2 in all cases. Low mineralization rates are ascribed to nutrient limitations and to lack of adaptation by microbial communities to hydrocarbon contaminants. Plasmid frequency data for sediment bacteria similarly showed no correlation with proximity to the oil field, but, instead, showed correlation with water column depth at each sampling site. Significant differences between sites were observed for proportion of isolates carrying single or multiple plasmids and mean number of plasmids per isolate, each of which increased as a function of depth. PMID:16348204
Zhang, Sheng; Liu, Xiaodong; Jin, Xiaodong; Li, Hongfei; Sun, Jun; Gu, Xiaoyu
2018-06-01
In this paper, a novel flame retardant (ACS) was prepared by crosslinking chitosan with bis-(4-formylphenyl)-phenyl-phosphonate (ABPO). ACS in association with ammonium polyphosphate (APP) and organic modified montmorillonite (OMMT) were used to prepare flame retardant thermoplastic polyurethane (TPU) composite through melt blending. For the TPU sample containing 10% flame retardants, the limiting oxygen index was increased from 20.8 to 29.0%, the vertical burning (UL-94) rating was upgraded from no rating to V-0, and the peak heat release rate was decreased from 1090 to 284 kW/m 2 . The thermal gravity analysis (TGA) indicated that ACS had excellent char formation ability and could greatly enhance the thermal stability of TPU. The tensile strength and elongation at break for flame retardant sample could reach 16.5 MPa and 1443% respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Tarescavage, Anthony M; Marek, Ryan J; Finn, Jacob A; Hicks, Adam; Rapier, Jessica L; Ben-Porath, Yossef S
2013-01-01
Odland, Berthelson, Sharma, Martin, and Mittenberg ( 2013 ) caution that clinically elevated scale scores produced by members of the Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF; Ben-Porath & Tellegen, 2008 /2011) normative sample raise concerns about the potential for false positive findings of psychopathology. However, the MMPI-2-RF normative sample is intended to represent the general population of the United States, 26.2% of which met criteria for a Diagnostic and Statistical Manual-IV (APA, 1994 ) disorder in a 12-month period (Kessler, Chiu, Demler, & Walters, 2005 ). In the current study we compare scale elevation rates in the MMPI-2-RF normative sample to prevalence rates of mental disorders primarily drawn from the National Comorbidity Study Replication (Kessler et al., 2005 ). Our objective was to evaluate MMPI-2-RF elevation rates in an epidemiological context. Results indicate that MMPI-2-RF scale elevation rates were generally consistent with epidemiological data when examined in the context of standard interpretation guidelines for the inventory. We also reiterate Ben-Porath and Tellegen's (2008/2011) caution that MMPI-2-RF scale elevations alone are not sufficient to indicate the presence of psychiatric disorder. Rather they are best viewed as indications of the need to evaluate the individual for possible disorder(s). Implications of these results, limitations of this study, and future directions in research are discussed.
Prevalence of orthorexia nervosa is less than 1 %: data from a US sample.
Dunn, Thomas M; Gibbs, Josh; Whitney, Noelle; Starosta, Amy
2017-03-01
Orthorexia nervosa, or pathological dieting based on being "healthy," has been of growing interest. Clinical data are limited to less than a half-dozen case studies reporting instances of medical problems due to healthful eating. However, more than a dozen studies using a measure to identify orthorexia, the ORTO-15, report very high prevalence rates in non-clinical samples. Point prevalence rates are reported from 6 % to nearly 90 %. Such variability could be due to cultural issues or psychometric problems with the instrument. This study examines prevalence rate of orthorexia in a US sample. The ORTO-15 was administered to 275 US college students along with other questions regarding diet, exercise, and health. While the ORTO-15 indicated a prevalence rate of 71 %, only 20 % of the sample endorsed a dietary practice of removing a particular food type (e.g. meat) from their diet. Those who endorsed following a vegan diet had the highest (less pathological) mean ORTO-15 score. Further, when classifying participants based on their seriousness about healthy eating and whether their diet had led to impairment in everyday activities and medical problems, less than 1 % of the sample fell into such a category. As in other countries, a large proportion of a non-clinical US sample scored in the orthorexia range on the ORTO-15. However, this instrument is likely unable to distinguish between healthy eating and pathologically healthful eating. Our estimate is that orthorexia nervosa like anorexia nervosa and bulimia nervosa, is not a common condition.
GNSS seismometer: Seismic phase recognition of real-time high-rate GNSS deformation waves
NASA Astrophysics Data System (ADS)
Nie, Zhaosheng; Zhang, Rui; Liu, Gang; Jia, Zhige; Wang, Dijin; Zhou, Yu; Lin, Mu
2016-12-01
High-rate global navigation satellite systems (GNSS) can potentially be used as seismometers to capture short-period instantaneous dynamic deformation waves from earthquakes. However, the performance and seismic phase recognition of the GNSS seismometer in the real-time mode, which plays an important role in GNSS seismology, are still uncertain. By comparing the results of accuracy and precision of the real-time solution using a shake table test, we found real-time solutions to be consistent with post-processing solutions and independent of sampling rate. In addition, we analyzed the time series of real-time solutions for shake table tests and recent large earthquakes. The results demonstrated that high-rate GNSS have the ability to retrieve most types of seismic waves, including P-, S-, Love, and Rayleigh waves. The main factor limiting its performance in recording seismic phases is the widely used 1-Hz sampling rate. The noise floor also makes recognition of some weak seismic phases difficult. We concluded that the propagation velocities and path of seismic waves, macro characteristics of the high-rate GNSS array, spatial traces of seismic phases, and incorporation of seismographs are all useful in helping to retrieve seismic phases from the high-rate GNSS time series.
The far-infrared properties of the CfA galaxy sample. I - The catalog
NASA Technical Reports Server (NTRS)
Thuan, T. X.; Sauvage, M.
1992-01-01
IRAS flux densities are presented for all galaxies in the Center for Astrophysics magnitude-limited sample (mB not greater than 14.5) detected in the IRAS Faint Source Survey (FSS), a total of 1544 galaxies. The detection rate in the FSS is slightly larger than in the PSC for the long-wavelength 60- and 100-micron bands, but improves by a factor of about 3 or more for the short wavelength 12- and 25-micron bands. This optically selected sample consists of galaxies which are, on average, much less IR-active than galaxies in IR-selected samples. It possesses accurate and complete redshift, morphological, and magnitude information, along with observations at other wavelengths.
Solid phase microextraction Arrow for the sampling of volatile amines in wastewater and atmosphere.
Helin, Aku; Rönkkö, Tuukka; Parshintsev, Jevgeni; Hartonen, Kari; Schilling, Beat; Läubli, Thomas; Riekkola, Marja-Liisa
2015-12-24
A new method is introduced for the sampling of volatile low molecular weight alkylamines in ambient air and wastewater by utilizing a novel SPME Arrow system, which contains a larger volume of sorbent compared to a standard SPME fiber. Parameters affecting the extraction, such as coating material, need for preconcentration, sample volume, pH, stirring rate, salt addition, extraction time and temperature were carefully optimized. In addition, analysis conditions, including desorption temperature and time as well as gas chromatographic parameters, were optimized. Compared to conventional SPME fiber, the SPME Arrow had better robustness and sensitivity. Average intermediate reproducibility of the method expressed as relative standard deviation was 12% for dimethylamine and 14% for trimethylamine, and their limit of quantification 10μg/L and 0.13μg/L respectively. Working range was from limits of quantification to 500μg/L for dimethylamine and to 130μg/L for trimethylamine. Several alkylamines were qualitatively analyzed in real samples, while target compounds dimethyl- and trimethylamines were quantified. The concentrations in influent and effluent wastewater samples were almost the same (∼80μg/L for dimethylamine, 120μg/L for trimethylamine) meaning that amines pass the water purification process unchanged or they are produced at the same rate as they are removed. For the air samples, preconcentration with phosphoric acid coated denuder was required and the concentration of trimethylamine was found to be around 1ng/m(3). The developed method was compared with optimized method based on conventional SPME and advantages and disadvantages of both approaches are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Riess, Adam G.; Rodney, Steven A.; Scolnic, Daniel M.; Shafer, Daniel L.; Strolger, Louis-Gregory; Ferguson, Henry C.; Postman, Marc; Graur, Or; Maoz, Dan; Jha, Saurabh W.; Mobasher, Bahram; Casertano, Stefano; Hayden, Brian; Molino, Alberto; Hjorth, Jens; Garnavich, Peter M.; Jones, David O.; Kirshner, Robert P.; Koekemoer, Anton M.; Grogin, Norman A.; Brammer, Gabriel; Hemmati, Shoubaneh; Dickinson, Mark; Challis, Peter M.; Wolff, Schuyler; Clubb, Kelsey I.; Filippenko, Alexei V.; Nayyeri, Hooshang; U, Vivian; Koo, David C.; Faber, Sandra M.; Kocevski, Dale; Bradley, Larry; Coe, Dan
2018-02-01
We present an analysis of 15 Type Ia supernovae (SNe Ia) at redshift z> 1 (9 at 1.5< z< 2.3) recently discovered in the CANDELS and CLASH Multi-Cycle Treasury programs using WFC3 on the Hubble Space Telescope. We combine these SNe Ia with a new compilation of ∼1050 SNe Ia, jointly calibrated and corrected for simulated survey biases to produce accurate distance measurements. We present unbiased constraints on the expansion rate at six redshifts in the range 0.07< z< 1.5 based only on this combined SN Ia sample. The added leverage of our new sample at z> 1.5 leads to a factor of ∼3 improvement in the determination of the expansion rate at z = 1.5, reducing its uncertainty to ∼20%, a measurement of H(z=1.5)/{H}0 = {2.69}-0.52+0.86. We then demonstrate that these six derived expansion rate measurements alone provide a nearly identical characterization of dark energy as the full SN sample, making them an efficient compression of the SN Ia data. The new sample of SNe Ia at z> 1.5 usefully distinguishes between alternative cosmological models and unmodeled evolution of the SN Ia distance indicators, placing empirical limits on the latter. Finally, employing a realistic simulation of a potential Wide-Field Infrared Survey Telescope SN survey observing strategy, we forecast optimistic future constraints on the expansion rate from SNe Ia.
Edwards, T.C.; Cutler, D.R.; Zimmermann, N.E.; Geiser, L.; Moisen, Gretchen G.
2006-01-01
We evaluated the effects of probabilistic (hereafter DESIGN) and non-probabilistic (PURPOSIVE) sample surveys on resultant classification tree models for predicting the presence of four lichen species in the Pacific Northwest, USA. Models derived from both survey forms were assessed using an independent data set (EVALUATION). Measures of accuracy as gauged by resubstitution rates were similar for each lichen species irrespective of the underlying sample survey form. Cross-validation estimates of prediction accuracies were lower than resubstitution accuracies for all species and both design types, and in all cases were closer to the true prediction accuracies based on the EVALUATION data set. We argue that greater emphasis should be placed on calculating and reporting cross-validation accuracy rates rather than simple resubstitution accuracy rates. Evaluation of the DESIGN and PURPOSIVE tree models on the EVALUATION data set shows significantly lower prediction accuracy for the PURPOSIVE tree models relative to the DESIGN models, indicating that non-probabilistic sample surveys may generate models with limited predictive capability. These differences were consistent across all four lichen species, with 11 of the 12 possible species and sample survey type comparisons having significantly lower accuracy rates. Some differences in accuracy were as large as 50%. The classification tree structures also differed considerably both among and within the modelled species, depending on the sample survey form. Overlap in the predictor variables selected by the DESIGN and PURPOSIVE tree models ranged from only 20% to 38%, indicating the classification trees fit the two evaluated survey forms on different sets of predictor variables. The magnitude of these differences in predictor variables throws doubt on ecological interpretation derived from prediction models based on non-probabilistic sample surveys. ?? 2006 Elsevier B.V. All rights reserved.
Radon exhalation rates and effective radium contents of the soil samples in Adapazarı, Turkey
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuş, Adem, E-mail: adem.kus@ogr.sakarya.edu.tr; Yakut, Hakan, E-mail: hyakut@sakarya.edu.tr; Tabar, Emre, E-mail: etabar@sakarya.edu.tr
In this study effective radium content and radon exhalation rates in soil samples collected from Adapazarı district of Sakarya, Turkey have been measured using LR-115 type-II plastic track detectors by closed-can technique for the first time. The obtained effective radium contents are found to vary from 6.66 to 34.32 Bqkg{sup −1} with a mean value of 18.01 Bqkg{sup −1}. The radon exhalation rates measured in terms of mass and area of soil samples are found to vary from 50.35-259.41 mBqkg{sup −1}h{sup −1} with a mean value of 136.12 mBqkg{sup −1}h{sup −1} and 1035.18-5333.39 mBqm{sup −2}h{sup −1} with a mean valuemore » of mBqm{sup −2}h{sup −1}. All the measurements show that the values of radium content are under the safe limit recommended by Organization for Cooperation and Development.« less
NASA Astrophysics Data System (ADS)
Sugihara, Kenkoh
2009-10-01
A low-cost ADC (Analogue-to-Digital Converter) with shaping embedded for undergraduate physics laboratory is developed using a home made circuit and a PC sound card. Even though an ADC is needed as an essential part of an experimental set up, commercially available ones are very expensive and are scarce for undergraduate laboratory experiments. The system that is developed from the present work is designed for a gamma-ray spectroscopy laboratory with NaI(Tl) counters, but not limited. For this purpose, the system performance is set to sampling rate of 1-kHz with 10-bit resolution using a typical PC sound card with 41-kHz or higher sampling rate and 16-bit resolution ADC with an addition of a shaping circuit. Details of the system and the status of development will be presented. Ping circuit and PC soundcard as typical PC sound card has 41.1kHz or heiger sampling rate and 16bit resolution ADCs. In the conference details of the system and the status of development will be presented.
NASA Astrophysics Data System (ADS)
Ruthven, R. C.; Ketcham, R. A.; Kelly, E. D.
2015-12-01
Three-dimensional textural analysis of garnet porphyroblasts and electron microprobe analyses can, in concert, be used to pose novel tests that challenge and ultimately increase our understanding of metamorphic crystallization mechanisms. Statistical analysis of high-resolution X-ray computed tomography (CT) data of garnet porphyroblasts tells us the degree of ordering or randomness of garnets, which can be used to distinguish the rate-limiting factors behind their nucleation and growth. Electron microprobe data for cores, rims, and core-to-rim traverses are used as proxies to ascertain porphyroblast nucleation and growth rates, and the evolution of sample composition during crystallization. MnO concentrations in garnet cores serve as a proxy for the relative timing of nucleation, and rim concentrations test the hypothesis that MnO is in equilibrium sample-wide during the final stages of crystallization, and that concentrations have not been greatly altered by intracrystalline diffusion. Crystal size distributions combined with compositional data can be used to quantify the evolution of nucleation rates and sample composition during crystallization. This study focuses on quartzite schists from the Picuris Mountains with heterogeneous garnet distributions consisting of dense and sparse layers. 3D data shows that the sparse layers have smaller, less euhedral garnets, and petrographic observations show that sparse layers have more quartz and less mica than dense layers. Previous studies on rocks with homogeneously distributed garnet have shown that crystallization rates are diffusion-controlled, meaning that they are limited by diffusion of nutrients to growth and nucleation sites. This research extends this analysis to heterogeneous rocks to determine nucleation and growth rates, and test the assumption of rock-wide equilibrium for some major elements, among a set of compositionally distinct domains evolving in mm- to cm-scale proximity under identical P-T conditions.
NASA Astrophysics Data System (ADS)
Cooperdock, S.; Breecker, D.
2016-12-01
Like all forest disturbances, wildfires remove vegetation but additionally they can remove or transform soil nutrients through volatilization due to extreme temperatures. As the stability and nutrient source for plants, soils are the key to forest regeneration after disturbances and in order to predict and mitigate damage, it is essential to understand how soils are affected by fires. In this study, soil respiration and temperature were measured in-situ at 20 sites affected by two fires that occurred during September 2011 and October 2015 in Bastrop County TX. At each site, soil samples were collected from 0-5 cm depth. These samples were incubated in the dark at 25° C and 22% water content to determine respiration rates under controlled environmental conditions. Total C, N, trace element concentrations and pH were measured in each soil sample to determine the effect of fire on soil chemistry and the effect of soil chemistry on soil activity. These methods of respiration measurement were performed to distinguish the impact of environmental and chemical factors on soil biological activity. Results show that from May to July 2016, soil temperatures increased an average of 6° C and 1° C more in burned areas than in unburned areas at depths of 5 cm and 15 cm, respectively. This likely results from fire-induced decrease in overstory cover, decrease in organic matter insulation and darkening soil color. Increasing temperatures correspond with a decrease in water content and respiration. Pearson's tests of the effect of soil moisture loss on a decrease of in-situ respiration rate show a correlation for burned soils, especially at sites burned in both fires (rho=0.90, p=0.04) and no correlation for unburned soils, suggesting a larger impact of environmental factors on soil activity in burned soils. Microcosm experiments show N concentration significantly affects respiration rate in unburned plots (rho=0.89, p=0.04) and both N (rho=0.92, p=0.03) and C concentration (rho=0.92, p=0.03) affect respiration rate in plots burned in 2011. No correlation was detected between nutrient concentration and respiration rate in recently burned plots, suggesting a larger influence of nutrient limitation on regeneration as time since burn increases. These results reveal that the limiting factors governing soil activity shift after wildfires.
Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler
Stewart, Justin; Sleeth, Darrah K.; Handy, Rod G.; Pahler, Leon F.; Anthony, T. Renee; Volckens, John
2017-01-01
A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler’s performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times. PMID:27676440
Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler.
Stewart, Justin; Sleeth, Darrah K; Handy, Rod G; Pahler, Leon F; Anthony, T Renee; Volckens, John
2017-03-01
A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler's performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times.
Distributed autonomous systems: resource management, planning, and control algorithms
NASA Astrophysics Data System (ADS)
Smith, James F., III; Nguyen, ThanhVu H.
2005-05-01
Distributed autonomous systems, i.e., systems that have separated distributed components, each of which, exhibit some degree of autonomy are increasingly providing solutions to naval and other DoD problems. Recently developed control, planning and resource allocation algorithms for two types of distributed autonomous systems will be discussed. The first distributed autonomous system (DAS) to be discussed consists of a collection of unmanned aerial vehicles (UAVs) that are under fuzzy logic control. The UAVs fly and conduct meteorological sampling in a coordinated fashion determined by their fuzzy logic controllers to determine the atmospheric index of refraction. Once in flight no human intervention is required. A fuzzy planning algorithm determines the optimal trajectory, sampling rate and pattern for the UAVs and an interferometer platform while taking into account risk, reliability, priority for sampling in certain regions, fuel limitations, mission cost, and related uncertainties. The real-time fuzzy control algorithm running on each UAV will give the UAV limited autonomy allowing it to change course immediately without consulting with any commander, request other UAVs to help it, alter its sampling pattern and rate when observing interesting phenomena, or to terminate the mission and return to base. The algorithms developed will be compared to a resource manager (RM) developed for another DAS problem related to electronic attack (EA). This RM is based on fuzzy logic and optimized by evolutionary algorithms. It allows a group of dissimilar platforms to use EA resources distributed throughout the group. For both DAS types significant theoretical and simulation results will be presented.
Balance of constructive and destructive carbonate processes on mesophotic coral reefs
NASA Astrophysics Data System (ADS)
Weinstein, D. K.; Klaus, J. S.; Smith, T. B.; Helmle, K. P.; Marshall, D.
2013-12-01
Net carbonate accumulation of coral reefs is the product of both constructive and destructive processes that can ultimately influence overall reef geomorphology. Differences in these processes with depth may in part explain why the coral growth-light intensity association does no result in the traditionally theorized reef accretion decrease with depth. Until recently, physical sampling limitations had prevented the acquisition of sedimentary data needed to assess in situ carbonate accumulation in mesophotic reefs (30-150 m). Coral framework production, secondary carbonate production (calcareous encrusters), and bioerosion, the three most critical components of net carbonate accumulation, were analyzed in mesophotic reefs more than 10 km south of St. Thomas, U.S. Virgin Islands along a very gradual slope that limits sediment transport and sedimentation. Recently dead samples of the massive coral, Orbicella annularis collected from three structurally different upper mesophotic coral reef habitats (30-45 m) were cut parallel to the primary growth axis to identify density banding through standard x-radiographic techniques. Assuming annual banding, mesophotic linear extension rates were calculated on the order of 0.7-1.5 mm/yr. Weight change of experimental coral substrates exposed for 3 years indicate differing rates (1.1-17.2 g/yr) of bioerosion and secondary accretion between mesophotic sites. When correcting bioerosion rates for high mesophotic skeletal density, carbonate accumulation rates were found to vary significantly between neighboring mesophotic reefs with distinctive structures. Results imply variable rates of mesophotic reef net carbonate accretion with the potential to influence overall reef/platform morphology, including localized mesophotic reef structure.
Raschke, Robert A; Groves, Robert H; Khurana, Hargobind S; Nikhanj, Nidhi; Utter, Ethel; Hartling, Didi; Stoffer, Brenda; Nunn, Kristina; Tryon, Shona; Bruner, Michelle; Calleja, Maria; Curry, Steven C
2017-01-01
Sepsis is a leading cause of mortality and morbidity in hospitalised patients. The Centers for Medicare and Medicaid Services (CMS) mandated that US hospitals report sepsis bundle compliance rate as a quality process measure in October 2015. The specific aim of our study was to improve the CMS sepsis bundle compliance rate from 30% to 40% across 20 acute care hospitals in our healthcare system within 1 year. The study included all adult inpatients with sepsis sampled according to CMS specifications from October 2015 to September 2016. The CMS sepsis bundle compliance rate was tracked monthly using statistical process control charting. A baseline rate of 28.5% with 99% control limits was established. We implemented multiple interventions including computerised decision support systems (CDSSs) to increase compliance with the most commonly missing bundle elements. Compliance reached 42% (99% statistical process control limits 18.4%-38.6%) as CDSS was implemented system-wide, but this improvement was not sustained after CMS changed specifications of the outcome measure. Difficulties encountered elucidate shortcomings of our study methodology and of the CMS sepsis bundle compliance rate as a quality process measure.
A passive integrative sampler for mercury vapor in air and neutral mercury species in water
Brumbaugh, W.G.; Petty, J.D.; May, T.W.; Huckins, J.N.
2000-01-01
A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15 x 2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ??? 5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress. (C) 1999 Elsevier Science Ltd.A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15??2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ???5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress.
Fidler, Richard L; Pelter, Michele M; Drew, Barbara J; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J Matt; Hu, Xiao
2017-01-01
Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.
Nonlinear flow affects hydrodynamic forces and neutrophil adhesion rates in cone-plate viscometers.
Shankaran, H; Neelamegham, S
2001-01-01
We present a theoretical and experimental analysis of the effects of nonlinear flow in a cone-plate viscometer. The analysis predicts that flow in the viscometer is a function of two parameters, the Reynolds number and the cone angle. Nonlinear flow occurs at high shear rates and causes spatial variations in wall shear stress, collision frequency, interparticle forces and attachment times within the viscometer. We examined the effect of these features on cellular adhesion kinetics. Based on recent data (Taylor, A. D., S. Neelamegham, J. D. Hellums, et al. 1996. Biophys. J. 71:3488-3500), we modeled neutrophil homotypic aggregation as a process that is integrin-limited at low shear and selectin-limited at high shear. Our calculations suggest that selectin and integrin on-rates lie in the order of 10(-2)-10(-4)/s. They also indicate that secondary flow causes positional variations in adhesion efficiency in the viscometer, and that the overall efficiency is dependent not only on the shear rate, but also the sample volume and the cone angle. Experiments performed with isolated neutrophils confirmed these predictions. In these experiments, enhancing secondary flow by increasing the sample volume from 100 to 1000 microl at 1500/s for a 2 degrees cone caused up to an approximately 45% drop in adhesion efficiency. Our results suggest that secondary flow may significantly influence cellular aggregation, platelet activation, and endothelial cell mechanotransduction measurements made in the viscometer over the range of conditions applied in typical biological studies. PMID:11371440
Assessment of natural radionuclides and its radiological hazards from tiles made in Nigeria
NASA Astrophysics Data System (ADS)
Joel, E. S.; Maxwell, O.; Adewoyin, O. O.; Ehi-Eromosele, C. O.; Embong, Z.; Saeed, M. A.
2018-03-01
Activity concentration of 10 different brands of tiles made in Nigeria were analyzed using High purity Germanium gamma detector and its hazard indices such as absorbed dose rate, radium equivalent activity, external Hazard Index (Hex), internal Hazard Index (Hin), Annual Effective Dose (mSv/y), Gamma activity Index (Iγ) and Alpha Index (Iα) were determined. The result showed that the average activity concentrations of radionuclides (226Ra, 232Th and 40K) content are within the recommended limit. The average radium equivalent is within the recommended limit of 370 Bq/kg. The result obtained further showed that the mean values for the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, gamma activity index and Alpha Index were: 169.22 nGyh-1, 0.95 and 1.14, 1.59 mSv/y, 1.00 Sv yr-1 and 0.34 respectively. The result established that radiological hazards such as absorbed dose rate, internal hazard, annual effective dose rate, gamma activity index and Alpha Index for some samples are found to be slightly close or above international recommended values. The result for the present study was compared with tiles sample from others countries, it was observed that the concentration of tiles made in Nigeria and other countries are closer, however recommends proper radiation monitoring for some tiles made in Nigeria before usage due to the long term health effect.
Kohigashi, Tsuyoshi; Otsuka, Yoichi; Shimazu, Ryo; Matsumoto, Takuya; Iwata, Futoshi; Kawasaki, Hideya; Arakawa, Ryuichi
2016-01-01
Mass spectrometry imaging (MSI) with ambient sampling and ionization can rapidly and easily capture the distribution of chemical components in a solid sample. Because the spatial resolution of MSI is limited by the size of the sampling area, reducing sampling size is an important goal for high resolution MSI. Here, we report the first use of a nanopipette for sampling and ionization by tapping-mode scanning probe electrospray ionization (t-SPESI). The spot size of the sampling area of a dye molecular film on a glass substrate was decreased to 6 μm on average by using a nanopipette. On the other hand, ionization efficiency increased with decreasing solvent flow rate. Our results indicate the compatibility between a reduced sampling area and the ionization efficiency using a nanopipette. MSI of micropatterns of ink on a glass and a polymer substrate were also demonstrated. PMID:28101441
Walters, Stephen J; Bonacho Dos Anjos Henriques-Cadby, Inês; Bortolami, Oscar; Flight, Laura; Hind, Daniel; Jacques, Richard M; Knox, Christopher; Nadin, Ben; Rothwell, Joanne; Surtees, Michael; Julious, Steven A
2017-03-20
Substantial amounts of public funds are invested in health research worldwide. Publicly funded randomised controlled trials (RCTs) often recruit participants at a slower than anticipated rate. Many trials fail to reach their planned sample size within the envisaged trial timescale and trial funding envelope. To review the consent, recruitment and retention rates for single and multicentre randomised control trials funded and published by the UK's National Institute for Health Research (NIHR) Health Technology Assessment (HTA) Programme. HTA reports of individually randomised single or multicentre RCTs published from the start of 2004 to the end of April 2016 were reviewed. Information was extracted, relating to the trial characteristics, sample size, recruitment and retention by two independent reviewers. Target sample size and whether it was achieved; recruitment rates (number of participants recruited per centre per month) and retention rates (randomised participants retained and assessed with valid primary outcome data). This review identified 151 individually RCTs from 787 NIHR HTA reports. The final recruitment target sample size was achieved in 56% (85/151) of the RCTs and more than 80% of the final target sample size was achieved for 79% of the RCTs (119/151). The median recruitment rate (participants per centre per month) was found to be 0.92 (IQR 0.43-2.79) and the median retention rate (proportion of participants with valid primary outcome data at follow-up) was estimated at 89% (IQR 79-97%). There is considerable variation in the consent, recruitment and retention rates in publicly funded RCTs. Investigators should bear this in mind at the planning stage of their study and not be overly optimistic about their recruitment projections. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Re-estimating sample size in cluster randomised trials with active recruitment within clusters.
van Schie, S; Moerbeek, M
2014-08-30
Often only a limited number of clusters can be obtained in cluster randomised trials, although many potential participants can be recruited within each cluster. Thus, active recruitment is feasible within the clusters. To obtain an efficient sample size in a cluster randomised trial, the cluster level and individual level variance should be known before the study starts, but this is often not the case. We suggest using an internal pilot study design to address this problem of unknown variances. A pilot can be useful to re-estimate the variances and re-calculate the sample size during the trial. Using simulated data, it is shown that an initially low or high power can be adjusted using an internal pilot with the type I error rate remaining within an acceptable range. The intracluster correlation coefficient can be re-estimated with more precision, which has a positive effect on the sample size. We conclude that an internal pilot study design may be used if active recruitment is feasible within a limited number of clusters. Copyright © 2014 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Pragourpun, Kraivinee; Sakee, Uthai; Fernandez, Carlos; Kruanetr, Senee
2015-05-01
We present for the first time the use of deferiprone as a non-toxic complexing agent for the determination of iron by sequential injection analysis in pharmaceuticals and food samples. The method was based on the reaction of Fe(III) and deferiprone in phosphate buffer at pH 7.5 to give a Fe(III)-deferiprone complex, which showed a maximum absorption at 460 nm. Under the optimum conditions, the linearity range for iron determination was found over the range of 0.05-3.0 μg mL-1 with a correlation coefficient (r2) of 0.9993. The limit of detection and limit of quantitation were 0.032 μg mL-1 and 0.055 μg mL-1, respectively. The relative standard deviation (%RSD) of the method was less than 5.0% (n = 11), and the percentage recovery was found in the range of 96.0-104.0%. The proposed method was satisfactorily applied for the determination of Fe(III) in pharmaceuticals, water and food samples with a sampling rate of 60 h-1.
Mercury content in marketed cosmetics: analytical survey in Shijiazhuang, China.
Wang, Li; Zhang, Hong
2015-01-01
Mercury is one of the skin-lightening ingredients in cosmetics as mercury ions are thought to inhibit the synthesis of the skin pigment melanin in melanocyte cells. The objective of this study was to evaluate the mercury levels of cosmetics currently marketed in Shijiazhuang, a northern city in China. We collected 146 random cosmetic samples and analyzed for mercury concentrations or levels by cold vapor atomic absorption spectrometry. Among the 146 samples, 134 (91.8%) were positive for mercury, and the concentrations of mercury ranged from not detectable to 592 ng/g. Cosmetic samples for children and babies had the highest detection rate (100%), followed by shampoo and hair conditioner (92.3%) and skin-lightening cream (92.0%). All of them were lower than the acceptable limit (1 μg/g) in China. Cosmetics for skin had the highest mean mercury content (45 ng/g), followed by hair products (42.1 ng/g). The concentrations of mercury detected in samples were lower than the current legal limit in China, indicating it may not pose a risk to consumers.
Deposition Rates and Characterization of Arabian Mineral Dust
NASA Astrophysics Data System (ADS)
Puthan Purakkal, J.; Stenchikov, G. L.; Engelbrecht, J. P.
2015-12-01
Airborne mineral dust directly and indirectly impacts on global climate, continental and marine biochemistry, human and animal health, agriculture, equipment, and visibility. Annual global dust emissions are poorly known with estimates differing by a factor of at least two. Local dust emission and deposition rates are even less quantified. Dust deposition rate is a key parameter, which helps to constrain the modeled dust budget of the atmosphere. However, dust deposition remains poorly known, due to the limited number of reliable measurements. Simulations and satellite observations suggest that coastal dusts contribute substantially to the total deposition flux into the Red Sea. Starting December 2014, deposition samplers, both the "frisbee" type, and passive samplers for individual particle scanning electron microscopy were deployed at King Abdullah University of Science and Technology (KAUST), along the Red Sea in Saudi Arabia. Sampling periods of one month were adopted. The deposition rates range from 3 g m-2 month-1 for fair weather conditions to 23 g m-2 month-1 for high dust events. The X-ray diffraction (XRD) analyses of deposited dust samples show mineralogical compositions different from any of the parent soils, the former consisting mainly of gypsum, calcite, and smaller amounts of albite, montmorillonite, chlorite, quartz and biotite. The deposited dust samples on the other hand contain more gypsum and less quartz than the previously collected soil samples. This presentation discusses the results from XRD, chemical analysis and SEM-based individual particle analysis of the soils and the deposited dust samples. The monthly dust accumulation rates and their seasonal and spatial variability are compared with the regional model predictions. Data from this study provide an observational basis for validating the regional dust mass balance along the Arabian Red Sea coastal plain.
Lai, Hsien-Tang; Kung, Pei-Tseng; Su, Hsun-Pi; Tsai, Wen-Chen
2014-09-01
Limited studies with large samples have been conducted on the utilization of dental calculus scaling among people with physical or mental disabilities. This study aimed to investigate the utilization of dental calculus scaling among the national disabled population. This study analyzed the utilization of dental calculus scaling among the disabled people, using the nationwide data between 2006 and 2008. Descriptive analysis and logistic regression were performed to analyze related influential factors for dental calculus scaling utilization. The dental calculus scaling utilization rate among people with physical or mental disabilities was 16.39%, and the annual utilization frequency was 0.2 times. Utilization rate was higher among the female and non-aboriginal samples. Utilization rate decreased with increased age and disability severity while utilization rate increased with income, education level, urbanization of residential area and number of chronic illnesses. Related influential factors for dental calculus scaling utilization rate were gender, age, ethnicity (aboriginal or non-aboriginal), education level, urbanization of residence area, income, catastrophic illnesses, chronic illnesses, disability types, and disability severity significantly influenced the dental calculus scaling utilization rate. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dose-rate-dependent damage of cerium dioxide in the scanning transmission electron microscope.
Johnston-Peck, Aaron C; DuChene, Joseph S; Roberts, Alan D; Wei, Wei David; Herzing, Andrew A
2016-11-01
Beam damage caused by energetic electrons in the transmission electron microscope is a fundamental constraint limiting the collection of artifact-free information. Through understanding the influence of the electron beam, experimental routines may be adjusted to improve the data collection process. Investigations of CeO 2 indicate that there is not a critical dose required for the accumulation of electron beam damage. Instead, measurements using annular dark field scanning transmission electron microscopy and electron energy loss spectroscopy demonstrate that the onset of measurable damage occurs when a critical dose rate is exceeded. The mechanism behind this phenomenon is that oxygen vacancies created by exposure to a 300keV electron beam are actively annihilated as the sample re-oxidizes in the microscope environment. As a result, only when the rate of vacancy creation exceeds the recovery rate will beam damage begin to accumulate. This observation suggests that dose-intensive experiments can be accomplished without disrupting the native structure of the sample when executed using dose rates below the appropriate threshold. Furthermore, the presence of an encapsulating carbonaceous layer inhibits processes that cause beam damage, markedly increasing the dose rate threshold for the accumulation of damage. Published by Elsevier B.V.
Dose-rate-dependent damage of cerium dioxide in the scanning transmission electron microscope
Johnston-Peck, Aaron C.; DuChene, Joseph S.; Roberts, Alan D.; Wei, Wei David; Herzing, Andrew A.
2016-01-01
Beam damage caused by energetic electrons in the transmission electron microscope is a fundamental constraint limiting the collection of artifact-free information. Through understanding the influence of the electron beam, experimental routines may be adjusted to improve the data collection process. Investigations of CeO2 indicate that there is not a critical dose required for the accumulation of electron beam damage. Instead, measurements using annular dark field scanning transmission electron microscopy and electron energy loss spectroscopy demonstrate that the onset of measurable damage occurs when a critical dose rate is exceeded. The mechanism behind this phenomenon is that oxygen vacancies created by exposure to a 300 keV electron beam are actively annihilated as the sample re-oxidizes in the microscope environment. As a result, only when the rate of vacancy creation exceeds the recovery rate will beam damage begin to accumulate. This observation suggests that dose-intensive experiments can be accomplished without disrupting the native structure of the sample when executed using dose rates below the appropriate threshold. Furthermore, the presence of an encapsulating carbonaceous layer inhibits processes that cause beam damage, markedly increasing the dose rate threshold for the accumulation of damage. PMID:27469265
Adult Support and Substance Use among Homeless Youths Who Attend High School
ERIC Educational Resources Information Center
Ferguson, Kristin M.; Xie, Bin
2012-01-01
Background: Despite high rates of substance use among homeless youths, little is known about the interaction of substance-use risk and protective factors. Further, limited research exists on substance use by school-attending homeless youths, as extant studies have relied on street- and shelter-based samples. Objective: The purpose of this study…
ERIC Educational Resources Information Center
Kakouros, Efthymios; Maniadaki, Katerina; Karaba, Rania
2005-01-01
Research regarding attention deficit/hyperactivity disorder (AD/HD) among preschoolers is limited. This study explored prevalence rates of AD/HD on a community-based sample of preschoolers in Athens. Moreover, it examined the relationship between AD/HD and aggressive behaviour and explored sex differences in this relationship. Nursery teachers…
A Theoretical Basis for Entropy-Scaling Effects in Human Mobility Patterns.
Osgood, Nathaniel D; Paul, Tuhin; Stanley, Kevin G; Qian, Weicheng
2016-01-01
Characterizing how people move through space has been an important component of many disciplines. With the advent of automated data collection through GPS and other location sensing systems, researchers have the opportunity to examine human mobility at spatio-temporal resolution heretofore impossible. However, the copious and complex data collected through these logging systems can be difficult for humans to fully exploit, leading many researchers to propose novel metrics for encapsulating movement patterns in succinct and useful ways. A particularly salient proposed metric is the mobility entropy rate of the string representing the sequence of locations visited by an individual. However, mobility entropy rate is not scale invariant: entropy rate calculations based on measurements of the same trajectory at varying spatial or temporal granularity do not yield the same value, limiting the utility of mobility entropy rate as a metric by confounding inter-experimental comparisons. In this paper, we derive a scaling relationship for mobility entropy rate of non-repeating straight line paths from the definition of Lempel-Ziv compression. We show that the resulting formulation predicts the scaling behavior of simulated mobility traces, and provides an upper bound on mobility entropy rate under certain assumptions. We further show that this formulation has a maximum value for a particular sampling rate, implying that optimal sampling rates for particular movement patterns exist.
Derivative financial instruments and nonprofit health care providers.
Stewart, Louis J; Owhoso, Vincent
2004-01-01
This article examines the extent of derivative financial instrument use among US nonprofit health systems and the impact of these financial instruments on their cash flows, reported operating results, and financial risks. Our examination is conducted through a case study of New Jersey hospitals and health systems. We review the existing literature on interest rate derivative instruments and US hospitals and health systems. This literature describes the design of these derivative financial instruments and the theoretical benefits of their use by large health care provider organizations. Our contribution to the literature is to provide an empirical evaluation of derivative financial instruments usage among a geographically limited sample of US nonprofit health systems. We reviewed the audited financial statements of the 49 community hospitals and multi-hospital health systems operating in the state of New Jersey. We found that 8 percent of New Jersey's nonprofit health providers utilized interest rate derivatives with an aggregate principle value of $229 million. These derivative users combine interest rate swaps and caps to lower the effective interest costs of their long-term debt while limiting their exposure to future interest rate increases. In addition, while derivative assets and liabilities have an immaterial balance sheet impact, derivative related gains and losses are a material component of their reported operating results. We also found that derivative usage among these four health systems was responsible for generating positive cash flows in the range of 1 percent to 2 percent of their total 2001 cash flows from operations. As a result of our admittedly limited samples we conclude that interest rate swaps and caps are effective risk management tools. However, we also found that while these derivative financial instruments are useful hedges against the risks of issuing long-term financing instruments, they also expose derivative users to credit, contract termination and interest rate volatility risks. In conclusion, we find that these financial instruments can also generate negative as well as positive cash flows and have both a positive and negative impact on reported operating results.
Ecosystem and physiological controls over methane production in northern wetlands
NASA Technical Reports Server (NTRS)
Valentine, David W.; Holland, Elisabeth A.; Schimel, David S.
1994-01-01
Peat chemistry appears to exert primary control over methane production rates in the Canadian Northern Wetlands Study (NOWES) area. We determined laboratory methane production rate potentials in anaerobic slurries of samples collected from a transect of sites through the NOWES study area. We related methane production rates to indicators of resistance to microbial decay (peat C: N and lignin: N ratios) and experimentally manipulated substrate availability for methanogenesis using ethanol (EtOH) and plant litter. We also determined responses of methane production to pH and temperature. Methane production potentials declined along the gradient of sites from high rates in the coastal fens to low rates in the interior bogs and were generally highest in surface layers. Strong relationships between CH4 production potentials and peat chemistry suggested that methanogenesis was limited by fermentation rates. Methane production at ambient pH responded strongly to substrate additions in the circumneutral fens with narrow lignin: N and C: N ratios (delta CH4/delta EtOH = 0.9-2.3 mg/g) and weakly in the acidic bogs with wide C: N and lignin: N ratios (delta CH4/delta EtOH = -0.04-0.02 mg/g). Observed Q(sub 10) values ranged from 1.7 to 4.7 and generally increased with increasing substrate availability, suggesting that fermentation rates were limiting. Titration experiments generally demonstrated inhibition of methanogenesis by low pH. Our results suggest that the low rates of methane emission observed in interior bogs during NOWES likely resulted from pH and substrate quality limitation of the fermentation step in methane production and thus reflect intrinsically low methane production potentials. Low methane emission rates observed during NOWES will likely be observed in other northern wetland regions with similar vegetation chemistry.
Porto, Paolo; Walling, Desmond E; Cogliandro, Vanessa; Callegari, Giovanni
2016-11-01
In recent years, the fallout radionuclides caesium-137 ( 137 Cs) and unsupported lead-210 ( 210 Pb ex) have been successfully used to document rates of soil erosion in many areas of the world, as an alternative to conventional measurements. By virtue of their different half-lives, these two radionuclides are capable of providing information related to different time windows. 137 Cs measurements are commonly used to generate information on mean annual erosion rates over the past ca. 50-60 years, whereas 210 Pb ex measurements are able to provide information relating to a longer period of up to ca. 100 years. However, the time-integrated nature of the estimates of soil redistribution provided by 137 Cs and 210 Pb ex measurements can be seen as a limitation, particularly when viewed in the context of global change and interest in the response of soil redistribution rates to contemporary climate change and land use change. Re-sampling techniques used with these two fallout radionuclides potentially provide a basis for providing information on recent changes in soil redistribution rates. By virtue of the effectively continuous fallout input, of 210 Pb, the response of the 210 Pb ex inventory of a soil profile to changing soil redistribution rates and thus its potential for use with the re-sampling approach differs from that of 137 Cs. Its greater sensitivity to recent changes in soil redistribution rates suggests that 210 Pb ex may have advantages over 137 Cs for use in the re-sampling approach. The potential for using 210 Pb ex measurements in re-sampling studies is explored further in this contribution. Attention focuses on a small (1.38 ha) forested catchment in southern Italy. The catchment was originally sampled for 210 Pb ex measurements in 2001 and equivalent samples were collected from points very close to the original sampling points again in 2013. This made it possible to compare the estimates of mean annual erosion related to two different time windows. This comparison suggests that mean annual rates of net soil loss had increased during the period between the two sampling campaigns and that this increase was associated with a shift to an increased sediment delivery ratio. This change was consistent with independent information on likely changes in the sediment response of the study catchment provided by the available records of annual sediment yield and changes in the annual rainfall documented for the local area. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
de Andrade, Jailson B.; Tanner, Roger L.
A method is described for the specific collection of formaldehyde as hydroxymethanesulfonate on bisulfate-coated cellulose filters. Following extraction in aqueous acid and removal on unreacted bisulfite, the hydroxymethanesulfonate is decomposed by base, and HCHO is determined by DNPH (2,4-dinitrophenylhydrazine) derivatization and HPLC. Since the collection efficiency for formaldehyde is moderately high even when sampling ambient air at high-volume flow rates, a limit of detection of 0.2 ppbv is achieved with 30 min sampling times. Interference from acetaldehyde co-collected as 1-hydroxyethanesulfonate is <5% using this procedure. The technique shows promise for both short-term airborne sampling, and as a means of collecting mg-sized samples of HCHO on an inorganic matrix for carbon isotopic analyses.
The impact of hydrogen on the formability of AHSS in Nakajima tests
NASA Astrophysics Data System (ADS)
Gao, Qi; Han, Fei; Wortberg, Daniel; Bleck, Wolfgang; Liewald, Mathias
2016-10-01
The application of Advanced High Strength Steels (AHSS) in the design of automotive body-in-white structures meets the requirement of light weight construction. The susceptibility to Hydrogen Embrittlement however, limits the wide application of steel grades over 1000 MPa. Up to now, various published studies focused on the hydrogen effects on mechanical properties; the impact of hydrogen on formability was not clarified. The present work aims to evaluate the influence of hydrogen on forming limit and fracture behavior in different strain states during the forming process. The hydrogen concentration in the material was modified by cathodic electro-charging. Nakajima tests in three strain conditions on uncharged and pre-charged samples were carried out. The localized necking was determined on the basis of the representative thinning rate in necking areas. The results revealed the shift of forming limits and critical strains to fracture owing to the presence of massive hydrogen. The fractography by Scanning Electron Microscope gave evidence of typical hydrogen-induced cleavage fracture on pre-charged samples.
Possibilities for serial femtosecond crystallography sample delivery at future light sourcesa)
Chavas, L. M. G.; Gumprecht, L.; Chapman, H. N.
2015-01-01
Serial femtosecond crystallography (SFX) uses X-ray pulses from free-electron laser (FEL) sources that can outrun radiation damage and thereby overcome long-standing limits in the structure determination of macromolecular crystals. Intense X-ray FEL pulses of sufficiently short duration allow the collection of damage-free data at room temperature and give the opportunity to study irreversible time-resolved events. SFX may open the way to determine the structure of biological molecules that fail to crystallize readily into large well-diffracting crystals. Taking advantage of FELs with high pulse repetition rates could lead to short measurement times of just minutes. Automated delivery of sample suspensions for SFX experiments could potentially give rise to a much higher rate of obtaining complete measurements than at today's third generation synchrotron radiation facilities, as no crystal alignment or complex robotic motions are required. This capability will also open up extensive time-resolved structural studies. New challenges arise from the resulting high rate of data collection, and in providing reliable sample delivery. Various developments for fully automated high-throughput SFX experiments are being considered for evaluation, including new implementations for a reliable yet flexible sample environment setup. Here, we review the different methods developed so far that best achieve sample delivery for X-ray FEL experiments and present some considerations towards the goal of high-throughput structure determination with X-ray FELs. PMID:26798808
NASA Technical Reports Server (NTRS)
Sciortino, S.; Vaiana, G. S.; Harnden, F. R., Jr.; Ramella, M.; Morossi, C.
1990-01-01
An X-ray luminosity function is derived for a representative volume-limited sample of O-type stars selected from the catalog of Galactic O stars surveyed with the Einstein Observatory. It was found that, for the stars of this sample which is ten times larger than any previously analyzed, the level of X-ray emission is strongly correlated with bolometric luminosity, confirming previous findings of an Lx-L(bol) relationship (e.g., Harnden et al., 1979; Pallavicini et al., 1981). Correlations between the Lx and the mass loss rate with the wind terminal velocity or with the rotation rate were weak. However, there was a strong correlation with wind momentum flux as well as with the wind kinetic energy flux.
Comparison. US P-61 and Delft sediment samplers
Beverage, Joseph P.; Williams, David T.
1990-01-01
The Delft Bottle (DB) is a flow-through device designed by the Delft Hydraulic Laboratory (DHL), The Netherlands, to sample sand-sized sediment suspended in streams. The US P-61 sampler was designed by the Federal Interagency Sedimentation Project (FISP) at the St. Anthony Falls Hydraulic Laboratory, Minneapolis, Minnesota, to collect suspended sediment from deep, swift rivers. The results of two point-sampling tests in the United States, the Mississippi River near Vicksburg, Mississippi, in 1983 and the Colorado River near Blythe, California, in 1984, are provided in this report. These studies compare sand-transport rates, rather than total sediment-transport rates, because fine material washes through the DB sampler. In the United States, the commonly used limits for sand-sized material are 0.062 mm to 2.00 mm (Vanoni 1975).
Rössler, Erik; Mattea, Carlos; Stapf, Siegfried
2015-02-01
Low field Nuclear Magnetic Resonance increases the contrast of the longitudinal relaxation rate in many biological tissues; one prominent example is hyaline articular cartilage. In order to take advantage of this increased contrast and to profile the depth-dependent variations, high resolution parameter measurements are carried out which can be of critical importance in an early diagnosis of cartilage diseases such as osteoarthritis. However, the maximum achievable spatial resolution of parameter profiles is limited by factors such as sensor geometry, sample curvature, and diffusion limitation. In this work, we report on high-resolution single-sided NMR scanner measurements with a commercial device, and quantify these limitations. The highest achievable spatial resolution on the used profiler, and the lateral dimension of the sensitive volume were determined. Since articular cartilage samples are usually bent, we also focus on averaging effects inside the horizontally aligned sensitive volume and their impact on the relaxation profiles. Taking these critical parameters into consideration, depth-dependent relaxation time profiles with the maximum achievable vertical resolution of 20 μm are discussed, and are correlated with diffusion coefficient profiles in hyaline articular cartilage in order to reconstruct T(2) maps from the diffusion-weighted CPMG decays of apparent relaxation rates. Copyright © 2014 Elsevier Inc. All rights reserved.
Bunkoed, Opas; Rueankaew, Thanaschaphorn; Nurerk, Piyaluk; Kanatharana, Proespichaya
2016-06-01
Polyaniline coated cigarette filters were successfully synthesized and used as a solid-phase extraction sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons in water samples. The polyaniline helped to enhance the adsorption ability of polycyclic aromatic hydrocarbons on the sorbent through π-π interactions. The high porosity and large surface area of the cigarette filters helped to reduce backpressure and can be operated with high sample flow rate without loss of extraction efficiency. The developed sorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The parameters that affected the extraction efficiencies, i.e. polymerization time, type of desorption solvent and its volume, sample flow rate, sample volume, sample pH, ionic strength, and organic modifier were investigated. Under the optimal conditions, the method was linear over the range of 0.5-10 μg/L and a detection limit of 0.5 ng/L. This simple, rapid, and cost-effective method was successfully applied to the preconcentration of polycyclic aromatic hydrocarbons from water samples. The developed method provided a high enrichment factor with good extraction efficiency (85-98%) and a relative standard deviation <10%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Whole genome amplification and real-time PCR in forensic casework
Giardina, Emiliano; Pietrangeli, Ilenia; Martone, Claudia; Zampatti, Stefania; Marsala, Patrizio; Gabriele, Luciano; Ricci, Omero; Solla, Gianluca; Asili, Paola; Arcudi, Giovanni; Spinella, Aldo; Novelli, Giuseppe
2009-01-01
Background WGA (Whole Genome Amplification) in forensic genetics can eliminate the technical limitations arising from low amounts of genomic DNA (gDNA). However, it has not been used to date because any amplification bias generated may complicate the interpretation of results. Our aim in this paper was to assess the applicability of MDA to forensic SNP genotyping by performing a comparative analysis of genomic and amplified DNA samples. A 26-SNPs TaqMan panel specifically designed for low copy number (LCN) and/or severely degraded genomic DNA was typed on 100 genomic as well as amplified DNA samples. Results Aliquots containing 1, 0.1 and 0.01 ng each of 100 DNA samples were typed for a 26-SNPs panel. Similar aliquots of the same DNA samples underwent multiple displacement amplification (MDA) before being typed for the same panel. Genomic DNA samples showed 0% PCR failure rate for all three dilutions, whilst the PCR failure rate of the amplified DNA samples was 0% for the 1 ng and 0.1 ng dilutions and 0.077% for the 0.01 ng dilution. The genotyping results of both the amplified and genomic DNA samples were also compared with reference genotypes of the same samples obtained by direct sequencing. The genomic DNA samples showed genotype concordance rates of 100% for all three dilutions while the concordance rates of the amplified DNA samples were 100% for the 1 ng and 0.1 ng dilutions and 99.923% for the 0.01 ng dilution. Moreover, ten artificially-degraded DNA samples, which gave no results when analyzed by current forensic methods, were also amplified by MDA and genotyped with 100% concordance. Conclusion We investigated the suitability of MDA material for forensic SNP typing. Comparative analysis of amplified and genomic DNA samples showed that a large number of SNPs could be accurately typed starting from just 0.01 ng of template. We found that the MDA genotyping call and accuracy rates were only slightly lower than those for genomic DNA. Indeed, when 10 pg of input DNA was used in MDA, we obtained 99.923% concordance, indicating a genotyping error rate of 1/1299 (7.7 × 10-4). This is quite similar to the genotyping error rate of STRs used in current forensic analysis. Such efficiency and accuracy of SNP typing of amplified DNA suggest that MDA can also generate large amounts of genome-equivalent DNA from a minimal amount of input DNA. These results show for the first time that MDA material is suitable for SNP-based forensic protocols and in general when samples fail to give interpretable STR results. PMID:19366436
Suguihiro, Talita Mayumi; de Oliveira, Paulo Roberto; de Rezende, Edivaltrys Inayve Pissinati; Mangrich, Antonio Sálvio; Marcolino, Luiz Humberto; Bergamini, Márcio F
2013-09-01
This work describes for first time the use of electroanalytical techniques for evaluation of adsorptive proprieties of biochar using it as electrode modifier and its application for preconcentration and determination of Lead(II) and Cadmium(II) under differential pulse adsorptive voltammetric conditions (DPAdSV). Samples of biochars were obtained from castor oil cake using a predefined set of experimental conditions varying the heating rate (V), final temperature (T) and warm-up period (P) and subsequently used for carbon paste modified electrode (CPME) preparation. The proposed method was applied for Lead(II) and Cadmium(II) determination in spiked simulated industrial effluents and the limit of detection obtained for both metals were adequated for determination of these evaluated ions taking into account the limits established by Brazilian legislation. For all samples analyzed, recoveries ranged from 95% to 104% were obtained and no significative interferences were observed for common cations in water samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Xiaolan; He, Man; Chen, Beibei; Hu, Bin
2014-11-01
A novel method based on on-line polymer monolithic capillary microextraction (CME)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Au and Pd in biological samples. For this purpose, poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was prepared and functionalized with mercapto groups. The prepared monolith exhibited good selectivity to Au and Pd, and good resistance to strong acid with a long life span. Factors affecting the extraction efficiency of CME, such as sample acidity, sample flow rate, eluent conditions and coexisting ion interference were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) were 5.9 ng L- 1 for Au and 8.3 ng L- 1 for Pd, and the relative standard deviations (RSDs, c = 50 ng L-1, n = 7) were 6.5% for Au and 1.1% for Pd, respectively. The developed method was successfully applied to the determination of Au and Pd in human urine and serum samples with the recovery in the range of 84-118% for spiked samples. The developed on-line polymer monolithic CME-ICP-MS method has the advantages of rapidity, simplicity, low sample/reagent consumption, high sensitivity and is suitable for the determination of trace Au and Pd in biological samples with limited amount available and complex matrix.
Fish entrainment rates through towboat propellers in the Upper Mississippi and Illinois rivers
Jack, Killgore K.; Miranda, L.E.; Murphy, C.E.; Wolff, D.M.; Hoover, J.J.; Keevin, T.M.; Maynord, S.T.; Cornish, M.A.
2011-01-01
Aspecially designed netwas used to study fish entrainment and injury through towboat propellers in 13 pools of the Upper Mississippi and Illinois rivers. The net was attached to the stern of a 48.8-m-long towboat with twin propellers (in Kort propulsion nozzles), and sampling typically took place while the towboat pushed 15 loaded barges upstream at a time. In total, 254 entrainment samples over 894 km of the 13 study pools were collected. The sampling efforts produced 16,005 fish representing 15 families and at least 44 species; fish ranged in total length from 3 to 123 cm, but only 12.5-cm or longer fish were analyzed because smaller fish could escape through the mesh of the trawl. Clupeidae (68% of total catch) and Sciaenidae (21%) were the dominant families. We detected no effects of towboat operation variables (speed and engine [i.e., propeller] revolutions per minute [RPM]) on entrainment rate (i.e., fish/km), but entrainment rate showed a wedge-shaped distribution relative to hydraulic and geomorphic characteristics of the channel. Entrainment rate was low (30 fish/km). Although total entrainment rate was not related to engine RPM, the probability of being struck by a propeller increased with fish length and engine RPM. Limits on engine RPM in narrow, shallow, and sluggish reaches could reduce entrainment impact, particularly for large-bodied fish. ?? American Fisheries Society 2011.
Infrared dynamics of cold atoms on hot graphene membranes
NASA Astrophysics Data System (ADS)
Sengupta, Sanghita; Kotov, Valeri N.; Clougherty, Dennis P.
2016-06-01
We study the infrared dynamics of low-energy atoms interacting with a sample of suspended graphene at finite temperature. The dynamics exhibits severe infrared divergences order by order in perturbation theory as a result of the singular nature of low-energy flexural phonon emission. Our model can be viewed as a two-channel generalization of the independent boson model with asymmetric atom-phonon coupling. This allows us to take advantage of the exact nonperturbative solution of the independent boson model in the stronger channel while treating the weaker one perturbatively. In the low-energy limit, the exact solution can be viewed as a resummation (exponentiation) of the most divergent diagrams in the perturbative expansion. As a result of this procedure, we obtain the atom's Green function which we use to calculate the atom damping rate, a quantity equal to the quantum sticking rate. A characteristic feature of our results is that the Green's function retains a weak, infrared cutoff dependence that reflects the reduced dimensionality of the problem. As a consequence, we predict a measurable dependence of the sticking rate on graphene sample size. We provide detailed predictions for the sticking rate of atomic hydrogen as a function of temperature and sample size. The resummation yields an enhanced sticking rate relative to the conventional Fermi golden rule result (equivalent to the one-loop atom self-energy), as higher-order processes increase damping at finite temperature.
Ghasemi, Fakhradin; Kalatpour, Omid; Moghimbeigi, Abbas; Mohammadfam, Iraj
2017-03-04
High-risk unsafe behaviors (HRUBs) have been known as the main cause of occupational accidents. Considering the financial and societal costs of accidents and the limitations of available resources, there is an urgent need for managing unsafe behaviors at workplaces. The aim of the present study was to find strategies for decreasing the rate of HRUBs using an integrated approach of safety behavior sampling technique and Bayesian networks analysis. A cross-sectional study. The Bayesian network was constructed using a focus group approach. The required data was collected using the safety behavior sampling, and the parameters of the network were estimated using Expectation-Maximization algorithm. Using sensitivity analysis and belief updating, it was determined that which factors had the highest influences on unsafe behavior. Based on BN analyses, safety training was the most important factor influencing employees' behavior at the workplace. High quality safety training courses can reduce the rate of HRUBs about 10%. Moreover, the rate of HRUBs increased by decreasing the age of employees. The rate of HRUBs was higher in the afternoon and last days of a week. Among the investigated variables, training was the most important factor affecting safety behavior of employees. By holding high quality safety training courses, companies would be able to reduce the rate of HRUBs significantly.
Johanson, Helene C; Hyland, Valentine; Wicking, Carol; Sturm, Richard A
2009-04-01
We describe here a method for DNA elution from buccal cells and whole blood both collected onto Whatman FTA technology, using methanol fixation followed by an elution PCR program. Extracted DNA is comparable in quality to published Whatman FTA protocols, as judged by PCR-based genotyping. Elution of DNA from the dried sample is a known rate-limiting step in the published Whatman FTA protocol; this method enables the use of each 3-mm punch of sample for several PCR reactions instead of the standard, one PCR reaction per sample punch. This optimized protocol therefore extends the usefulness and cost effectiveness of each buccal swab sample collected, when used for nucleic acid PCR and genotyping.
NASA Astrophysics Data System (ADS)
Zhang, Jingdong; Zhu, Tao; Zheng, Hua; Kuang, Yang; Liu, Min; Huang, Wei
2017-04-01
The round trip time of the light pulse limits the maximum detectable frequency response range of vibration in phase-sensitive optical time domain reflectometry (φ-OTDR). We propose a method to break the frequency response range restriction of φ-OTDR system by modulating the light pulse interval randomly which enables a random sampling for every vibration point in a long sensing fiber. This sub-Nyquist randomized sampling method is suits for detecting sparse-wideband- frequency vibration signals. Up to MHz resonance vibration signal with over dozens of frequency components and 1.153MHz single frequency vibration signal are clearly identified for a sensing range of 9.6km with 10kHz maximum sampling rate.
Feasibility of biochemical verification in a web-based smoking cessation study.
Cha, Sarah; Ganz, Ollie; Cohn, Amy M; Ehlke, Sarah J; Graham, Amanda L
2017-10-01
Cogent arguments have been made against the need for biochemical verification in population-based studies with low-demand characteristics. Despite this fact, studies involving digital interventions (low-demand) are often required in peer review to report biochemically verified abstinence. To address this discrepancy, we examined the feasibility and costs of biochemical verification in a web-based study conducted with a national sample. Participants were 600U.S. adult current smokers who registered on a web-based smoking cessation program and completed surveys at baseline and 3months. Saliva sampling kits were sent to participants who reported 7-day abstinence at 3months, and analyzed for cotinine. The response rate at 3-months was 41.2% (n=247): 93 participants reported 7-day abstinence (38%) and were mailed a saliva kit (71% returned). The discordance rate was 36.4%. Participants with discordant responses were more likely to report 3-month use of nicotine replacement therapy or e-cigarettes than those with concordant responses (79.2% vs. 45.2%, p=0.007). The total cost of saliva sampling was $8280 ($125/sample). Biochemical verification was both time- and cost-intensive, and yielded a relatively small number of samples due to low response rates and use of other nicotine products during the follow-up period. There was a high rate of discordance of self-reported abstinence and saliva testing. Costs for data collection may be prohibitive for studies with large sample sizes or limited budgets. Our findings echo previous statements that biochemical verification is not necessary in population-based studies, and add evidence specific to technology-based studies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Self-Reported Functional Status among the Old-Old: A Comparison of Two Israeli Cohorts
Litwin, Howard; Shrira, Amit; Shmotkin, Dov
2012-01-01
OBJECTIVES To examine differences in functional status among two successive cohorts. METHODS The study was a comparative analysis of Jewish respondents aged 75–94 from two nationwide random samples: the Cross-Sectional and Longitudinal Aging Study (1989–1992; N =1200) and the Survey of Health, Ageing, and Retirement in Europe (2005–2006; N =379). Self-reported functional limitation and disability were compared by means of logistic regressions and MANCOVA, controlling for age, gender, origin, education, marital status, income, self-rated health, and home care receipt. RESULTS Reported functional limitation decreased in the later cohort (SHARE-Israel), but ADL- and IADL-disability increased. Receipt of home care moderated these effects. ADL- and IADL-disability increased among home-care-receiving respondents in the later cohort whereas functional limitation decreased among respondents not in receipt of home care. DISCUSSION The findings suggest that different measures used to assess the disablement process capture different aspects, and that contextual factors influence how older people rate their own functional capacity. PMID:22422761
Giuliana, D'Imporzano; Fabrizio, Adani
2007-02-01
This study aims to establish the contribution of the water soluble and water insoluble organic fractions to total oxygen uptake rate during high rate composting process of a mixture of organic fraction of municipal solid waste and lignocellulosic material. This mixture was composted using a 20 l self-heating pilot scale composter for 250 h. The composter was fully equipped to record both the biomass-temperature and oxygen uptake rate. Representative compost samples were taken at 0, 70, 100, 110, 160, and 250 h from starting time. Compost samples were fractionated in water soluble and water insoluble fractions. The water soluble fraction was then fractionated in hydrophilic, hydrophobic, and neutral hydrophobic fractions. Each fraction was then studied using quantitative (total organic carbon) and qualitative analysis (diffuse reflectance infrared spectroscopy and biodegradability test). Oxygen uptake rates were high during the initial stages of the process due to rapid degradation of the soluble degradable organic fraction (hydrophilic plus hydrophobic fractions). Once this fraction was depleted, polymer hydrolysis accounted for most of the oxygen uptake rate. Finally, oxygen uptake rate could be modeled using a two term kinetic. The first term provides the oxygen uptake rate resulting from the microbial growth kinetic type on easily available, no-limiting substrate (soluble fraction), while the second term considers the oxygen uptake rate caused by the degradation of substrate produced by polymer hydrolysis.
Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao
2017-08-01
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao
2017-08-01
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples.
Integrative missing value estimation for microarray data.
Hu, Jianjun; Li, Haifeng; Waterman, Michael S; Zhou, Xianghong Jasmine
2006-10-12
Missing value estimation is an important preprocessing step in microarray analysis. Although several methods have been developed to solve this problem, their performance is unsatisfactory for datasets with high rates of missing data, high measurement noise, or limited numbers of samples. In fact, more than 80% of the time-series datasets in Stanford Microarray Database contain less than eight samples. We present the integrative Missing Value Estimation method (iMISS) by incorporating information from multiple reference microarray datasets to improve missing value estimation. For each gene with missing data, we derive a consistent neighbor-gene list by taking reference data sets into consideration. To determine whether the given reference data sets are sufficiently informative for integration, we use a submatrix imputation approach. Our experiments showed that iMISS can significantly and consistently improve the accuracy of the state-of-the-art Local Least Square (LLS) imputation algorithm by up to 15% improvement in our benchmark tests. We demonstrated that the order-statistics-based integrative imputation algorithms can achieve significant improvements over the state-of-the-art missing value estimation approaches such as LLS and is especially good for imputing microarray datasets with a limited number of samples, high rates of missing data, or very noisy measurements. With the rapid accumulation of microarray datasets, the performance of our approach can be further improved by incorporating larger and more appropriate reference datasets.
Bouchard, Daniel; Wanner, Philipp; Luo, Hong; McLoughlin, Patrick W; Henderson, James K; Pirkle, Robert J; Hunkeler, Daniel
2017-10-20
The methodology of the solvent-based dissolution method used to sample gas phase volatile organic compounds (VOC) for compound-specific isotope analysis (CSIA) was optimized to lower the method detection limits for TCE and benzene. The sampling methodology previously evaluated by [1] consists in pulling the air through a solvent to dissolve and accumulate the gaseous VOC. After the sampling process, the solvent can then be treated similarly as groundwater samples to perform routine CSIA by diluting an aliquot of the solvent into water to reach the required concentration of the targeted contaminant. Among solvents tested, tetraethylene glycol dimethyl ether (TGDE) showed the best aptitude for the method. TGDE has a great affinity with TCE and benzene, hence efficiently dissolving the compounds during their transition through the solvent. The method detection limit for TCE (5±1μg/m 3 ) and benzene (1.7±0.5μg/m 3 ) is lower when using TGDE compared to methanol, which was previously used (385μg/m 3 for TCE and 130μg/m 3 for benzene) [2]. The method detection limit refers to the minimal gas phase concentration in ambient air required to load sufficient VOC mass into TGDE to perform δ 13 C analysis. Due to a different analytical procedure, the method detection limit associated with δ 37 Cl analysis was found to be 156±6μg/m 3 for TCE. Furthermore, the experimental results validated the relationship between the gas phase TCE and the progressive accumulation of dissolved TCE in the solvent during the sampling process. Accordingly, based on the air-solvent partitioning coefficient, the sampling methodology (e.g. sampling rate, sampling duration, amount of solvent) and the final TCE concentration in the solvent, the concentration of TCE in the gas phase prevailing during the sampling event can be determined. Moreover, the possibility to analyse for TCE concentration in the solvent after sampling (or other targeted VOCs) allows the field deployment of the sampling method without the need to determine the initial gas phase TCE concentration. The simplified field deployment approach of the solvent-based dissolution method combined with the conventional analytical procedure used for groundwater samples substantially facilitates the application of CSIA to gas phase studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Biological monitoring and standard setting in the USA: a critical appraisal.
Rappaport, S M
1995-05-01
Occupational exposure limits (OELs) issued in the US by the Occupational Safety and Health Administration (OSHA) require measurements of toxic substances in air rather than in biological samples. Most of OSHA's limits were adopted from the 1968 list of the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs). Although there are no formal requirements to monitor exposures to these substances, it is implicit in the standards that air sampling will be performed. Of the 13 OELs which OSHA has set de novo, 2 (i.e., those for lead and cadmium) require biomonitoring after air sampling has identified the heavily exposed workers. OSHA appears to value biomonitoring in some circumstances but has apparently not found a consistent rationale for using biomarkers to set and enforce its standards. This paper discusses 2 valuable features of biomarkers which should be exploited by OSHA to further its regulatory agenda. The first relates to controversies associated with dose rate which have come into play in setting short-term exposure limits (STELs) when acute effects do not provide the necessary justification. OSHA has not provided evidence that its STELs are needed to reduce the risks of disease (as in the cases of benzene and ethylene oxide). By investigating the exposure-biomarker relationship, it is possible to determine whether the rate of exposure has any influence on the uptake and elimination of toxic substances and, therefore, whether STELs is needed. This is illustrated with data from 2 studies on styrene exposure. The second feature concerns biomonitoring as the primary means of exposure assessment in situations where the biomarker is accumulated over months or years (as in the cases of lead and cadmium). Using data from the lead-battery industry, it is shown that 'correct' compliance decisions are more likely to arise from evaluation of blood lead measurements than from traditional air monitoring.
Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.
2014-01-01
Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149
NASA Astrophysics Data System (ADS)
Han, Qi-Gang; Yang, Wen-Ke; Zhu, Pin-Wen; Ban, Qing-Chu; Yan, Ni; Zhang, Qiang
2013-07-01
In order to increase the maximum cell pressure of the cubic high pressure apparatus, we have developed a new structure of tungsten carbide cubic anvil (tapered cubic anvil), based on the principle of massive support and lateral support. Our results indicated that the tapered cubic anvil has some advantages. First, tapered cubic anvil can push the transfer rate of pressure well into the range above 36.37% compare to the conventional anvil. Second, the rate of failure crack decreases about 11.20% after the modification of the conventional anvil. Third, the limit of static high-pressure in the sample cell can be extended to 13 GPa, which can increase the maximum cell pressure about 73.3% than that of the conventional anvil. Fourth, the volume of sample cell compressed by tapered cubic anvils can be achieved to 14.13 mm3 (3 mm diameter × 2 mm long), which is three and six orders of magnitude larger than that of double-stage apparatus and diamond anvil cell, respectively. This work represents a relatively simple method for achieving higher pressures and larger sample cell.
Jasuja, Guneet Kaur; Travison, Thomas G; Murabito, Joanne M; Davda, Maithili N; Rose, Adam J; Basaria, Shehzad; Coviello, Andrea; Vasan, Ramachandran S; D'Agostino, Ralph; Bhasin, Shalender
2017-08-01
Self-rated health is a commonly used global indicator of health status. Few studies have examined the association of self-rated health and mobility with estrone and estradiol in men. Accordingly, we determined the cross-sectional, incident, and mediating relations between circulating estrone and estradiol levels with self-rated health, mobility limitation, and physical performance in community-dwelling men. The cross-sectional sample included 1,148 men, who attended Framingham Offspring Study Examinations 7 and 8. Estrone and estradiol levels were measured using liquid chromatography tandem mass spectrometry at Examination 7. Self-reported mobility limitation and self-rated health were assessed at Examinations 7 and 8. Additionally, short physical performance battery, usual walking speed, and grip strength were assessed at Examination 7. In incident analysis, estradiol levels at Examination 7 were associated with increased odds of fair or poor self-rated health at Examination 8, after adjusting for age, body mass index, comorbidities, and testosterone levels; in an individual with 50% greater estradiol than other, the odds of reporting "fair or poor" self-rated health increased by 1.78 (95% confidence interval: 1.25-2.55; p = .001). Neither estrone nor estradiol levels were associated with any physical performance measure at baseline. Higher circulating levels of estradiol are associated with increased risk of incident fair/poor self-rated health in community-dwelling men. The mechanisms by which circulating levels of estradiol are related to self-rated health in men need further investigation. Published by Oxford University Press on behalf of The Gerontological Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Crowley, Stephanie J; Suh, Christina; Molina, Thomas A; Fogg, Louis F; Sharkey, Katherine M; Carskadon, Mary A
2016-04-01
Circadian rhythm sleep-wake disorders (CRSWDs) often manifest during the adolescent years. Measurement of circadian phase such as the dim light melatonin onset (DLMO) improves diagnosis and treatment of these disorders, but financial and time costs limit the use of DLMO phase assessments in clinic. The current analysis aims to inform a cost-effective and efficient protocol to measure the DLMO in older adolescents by reducing the number of samples and total sampling duration. A total of 66 healthy adolescents (26 males) aged 14.8-17.8 years participated in a study; they were required to sleep on a fixed baseline schedule for a week before which they visited the laboratory for saliva collection in dim light (<20 lux). Two partial 6-h salivary melatonin profiles were derived for each participant. Both profiles began 5 h before bedtime and ended 1 h after bedtime, but one profile was derived from samples taken every 30 min (13 samples) and the other from samples taken every 60 min (seven samples). Three standard thresholds (first three melatonin values mean + 2 SDs, 3 pg/mL, and 4 pg/mL) were used to compute the DLMO. An agreement between DLMOs derived from 30-min and 60-min sampling rates was determined using Bland-Altman analysis; agreement between the sampling rate DLMOs was defined as ± 1 h. Within a 6-h sampling window, 60-min sampling provided DLMO estimates within ± 1 h of DLMO from 30-min sampling, but only when an absolute threshold (3 or 4 pg/mL) was used to compute the DLMO. Future analyses should be extended to include adolescents with CRSWDs. Copyright © 2016 Elsevier B.V. All rights reserved.
Sanov and central limit theorems for output statistics of quantum Markov chains
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horssen, Merlijn van, E-mail: merlijn.vanhorssen@nottingham.ac.uk; Guţă, Mădălin, E-mail: madalin.guta@nottingham.ac.uk
2015-02-15
In this paper, we consider the statistics of repeated measurements on the output of a quantum Markov chain. We establish a large deviations result analogous to Sanov’s theorem for the multi-site empirical measure associated to finite sequences of consecutive outcomes of a classical stochastic process. Our result relies on the construction of an extended quantum transition operator (which keeps track of previous outcomes) in terms of which we compute moment generating functions, and whose spectral radius is related to the large deviations rate function. As a corollary to this, we obtain a central limit theorem for the empirical measure. Suchmore » higher level statistics may be used to uncover critical behaviour such as dynamical phase transitions, which are not captured by lower level statistics such as the sample mean. As a step in this direction, we give an example of a finite system whose level-1 (empirical mean) rate function is independent of a model parameter while the level-2 (empirical measure) rate is not.« less
Ginson, J; Panda, Satyen Kumar; Bindu, J; Kamalakanth, C K; Srinivasa Gopal, T K
2015-04-01
High pressure treatment of 250 MPa for 6 min at 25 °C was applied to headless Indian white prawn (Fenneropenaeus indicus) to evaluate changes in microbiological characteristics of the species during chilled storage. Changes in load of mesophilic bacteria, psychrotrophic bacteria, proteolytic bacteria, Enterobacteriaceae, Pseudomonas spp., H2S producing bacteria, lactic acid bacteria, Brochothrix thermosphacta and yeast & mold were estimated in pressurized and un-pressurized samples during chilled storage. All microbes were reduced significantly after high pressure treatment and there was significant difference in microbial quality of control and high pressure treated samples in the entire duration of chilled storage (p < 0.05). There was delay in the growth of Enterobacteriaceae and H2S producing bacteria up to 6th and 9th day of storage, respectively in high pressure treated samples. In high pressure treated sample, no lag phase (λ) was observed for psychrotrophic bacteria, H2S producing bacteria, B. thermosphacta, Pseudomonas spp. and lactic acid bacteria; however, other bacteria showed a reduced lag phase during chilled storage. Kinetic parameter such as specific growth rate (μmax) in high pressure treated samples was significantly reduced in most of the bacterial groups except for psychrotrophic bacteria, Enterobacteriaceae and lactic acid bacteria. Mesophilic bacterial count of control samples crossed the marginal limit of acceptability on 12th day and unacceptable limit on 18th day of storage, whereas high pressure treated samples never breached the acceptability limit during entire duration of chilled storage. The present study indicated that application of high pressure processing can be used to improve microbial quality of Indian white prawn and extend the chilled storage life. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zare-Dorabei, Rouholah; Boroun, Shokoufeh; Noroozifar, Meissam
2018-02-01
A new and simple flow injection method followed by atomic absorption spectrometry was developed for indirect determination of sulfite. The proposed method is based on the oxidation of sulfite to sulphate ion using solid-phase manganese dioxide (30% W/W suspended on silica gel beads) reactor. MnO 2 will be reduced to Mn(II) by sample injection in to the column under acidic carrier stream of HNO 3 (pH 2) with flow rate of 3.5mLmin -1 at room temperature. Absorption measurement of Mn(II) which is proportional to the concentration of sulfite in the sample was carried out by atomic absorption spectrometry. The calibration curve was linear up to 25mgL -1 with a detection limit (DL) of 0.08mgL -1 for 400µL injection sample volume. The presented method is efficient toward sulfite determination in sugar and water samples with a relative standard deviation (RSD) less than 1.2% and a sampling rate of about 60h -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Estimation of the indoor radon and the annual effective dose from granite samples
NASA Astrophysics Data System (ADS)
Sola, P.; Srinuttrakul, W.; Kewsuwan, P.
2015-05-01
Inhalation of radon and thoron daughters increases the risk of lung cancer. The main sources of indoor radon are building materials. The aim of this research is to estimate the indoor radon and the annual effective dose from the building materials. Eighteen granite samples bought from the markets in Thailand were measured using an ionization chamber (ATMOS 12 DPX) for the radon concentration in air. Radon exhalation rates were calculated from the radon concentration in chamber. The indoor radon from the granite samples ranged from 10.04 to 55.32 Bq·m-2·h-1 with an average value of 20.30 Bq·m-2·h-1 and the annual effective dose ranged from 0.25 to 1.39 mSv·y-1 with an average value of 0.48 mSv·y-1. The results showed that the annual effective doses of three granite samples were higher than the annual exposure limit for the general public (1 mSv·y-1) recommended by the International Commission on Radiological Protection (ICRP). In addition, the relationship between the colours and radon exhalation rates of granite samples was also explained.
Jin, Chan; Guan, Jibin; Zhang, Dong; Li, Bing; Liu, Hongzhuo; He, Zhonggui
2017-10-01
We present a technique to rapid determine taxane in blood samples by supercritical fluid chromatography together with mass spectrometry. The aim of this study was to develop a supercritical fluid chromatography with mass spectrometry method for the analysis of paclitaxel, cabazitaxel, and docetaxel in whole-blood samples of rats. Liquid-dry matrix spot extraction was selected in sample preparation procedure. Supercritical fluid chromatography separation of paclitaxel, cabazitaxel, docetaxel, and glyburide (internal standard) was accomplished within 3 min by using the gradient mobile phase consisted of methanol as the compensation solvent and carbon dioxide at a flow rate of 1.0 mL/min. The method was validated regarding specificity, the lower limit of quantification, repeatability, and reproducibility of quantification, extraction recovery, and matrix effects. The lower limit of quantification was found to be 10 ng/mL since it exhibited acceptable precision and accuracy at the corresponding level. All interday accuracies and precisions were within the accepted criteria of ±15% of the nominal value and within ±20% at the lower limit of quantification, implying that the method was reliable and reproducible. In conclusion, this method is a promising tool to support and improve preclinical or clinical pharmacokinetic studies with the taxanes anticancer drugs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Peng, Pei; Wang, Wei; Zhang, Li; Su, Shiguang; Wang, Jiahui
2013-12-04
The absorbance characteristics and influential factors on these characteristics for a liquid-phase gas sensor, which is based on gas-permeable liquid core waveguides (LCWs), are studied from theoretical and experimental viewpoints in this paper. According to theory, it is predicted that absorbance is proportional to the analyte concentration, sampling time, analyte diffusion coefficient, and geometric factor of this device when the depletion layer of the analyte is ignored. The experimental results are in agreement with the theoretical hypothesis. According to the experimental results, absorbance is time-dependent and increasing linearly over time after the requisite response time with a linear correlation coefficient r(2)>0.999. In the linear region, the rate of absorbance change (RAC) indicates improved linearity with sample concentration and a relative higher sensitivity than instantaneous absorbance does. By using a core liquid that is more affinitive to the analyte, reducing wall thickness and the inner diameter of the tubing, or increasing sample flow rate limitedly, the response time can be decreased and the sensitivity can be increased. However, increasing the LCW length can only enhance sensitivity and has no effect on response time. For liquid phase detection, there is a maximum flow rate, and the absorbance will decrease beyond the stated limit. Under experimental conditions, hexane as the LCW core solvent, a tubing wall thickness of 0.1 mm, a length of 10 cm, and a flow rate of 12 mL min(-1), the detection results for the aqueous benzene sample demonstrate a response time of 4 min. Additionally, the standard curve for the RAC versus concentration is RAC=0.0267c+0.0351 (AU min(-1)), with r(2)=0.9922 within concentrations of 0.5-3.0 mg L(-1). The relative error for 0.5 mg L(-1) benzene (n=6) is 7.4±3.7%, and the LOD is 0.04 mg L(-1). This research can provide theoretical and practical guides for liquid-phase gas sensor design and development based on a gas-permeable Teflon AF 2400 LCW. Copyright © 2013 Elsevier B.V. All rights reserved.
Does Aspartic Acid Racemization Constrain the Depth Limit of the Subsurface Biosphere?
NASA Technical Reports Server (NTRS)
Onstott, T C.; Magnabosco, C.; Aubrey, A. D.; Burton, A. S.; Dworkin, J. P.; Elsila, J. E.; Grunsfeld, S.; Cao, B. H.; Hein, J. E.; Glavin, D. P.;
2013-01-01
Previous studies of the subsurface biosphere have deduced average cellular doubling times of hundreds to thousands of years based upon geochemical models. We have directly constrained the in situ average cellular protein turnover or doubling times for metabolically active micro-organisms based on cellular amino acid abundances, D/L values of cellular aspartic acid, and the in vivo aspartic acid racemization rate. Application of this method to planktonic microbial communities collected from deep fractures in South Africa yielded maximum cellular amino acid turnover times of approximately 89 years for 1 km depth and 27 C and 1-2 years for 3 km depth and 54 C. The latter turnover times are much shorter than previously estimated cellular turnover times based upon geochemical arguments. The aspartic acid racemization rate at higher temperatures yields cellular protein doubling times that are consistent with the survival times of hyperthermophilic strains and predicts that at temperatures of 85 C, cells must replace proteins every couple of days to maintain enzymatic activity. Such a high maintenance requirement may be the principal limit on the abundance of living micro-organisms in the deep, hot subsurface biosphere, as well as a potential limit on their activity. The measurement of the D/L of aspartic acid in biological samples is a potentially powerful tool for deep, fractured continental and oceanic crustal settings where geochemical models of carbon turnover times are poorly constrained. Experimental observations on the racemization rates of aspartic acid in living thermophiles and hyperthermophiles could test this hypothesis. The development of corrections for cell wall peptides and spores will be required, however, to improve the accuracy of these estimates for environmental samples.
A Reconfigurable Real-Time Compressive-Sampling Camera for Biological Applications
Fu, Bo; Pitter, Mark C.; Russell, Noah A.
2011-01-01
Many applications in biology, such as long-term functional imaging of neural and cardiac systems, require continuous high-speed imaging. This is typically not possible, however, using commercially available systems. The frame rate and the recording time of high-speed cameras are limited by the digitization rate and the capacity of on-camera memory. Further restrictions are often imposed by the limited bandwidth of the data link to the host computer. Even if the system bandwidth is not a limiting factor, continuous high-speed acquisition results in very large volumes of data that are difficult to handle, particularly when real-time analysis is required. In response to this issue many cameras allow a predetermined, rectangular region of interest (ROI) to be sampled, however this approach lacks flexibility and is blind to the image region outside of the ROI. We have addressed this problem by building a camera system using a randomly-addressable CMOS sensor. The camera has a low bandwidth, but is able to capture continuous high-speed images of an arbitrarily defined ROI, using most of the available bandwidth, while simultaneously acquiring low-speed, full frame images using the remaining bandwidth. In addition, the camera is able to use the full-frame information to recalculate the positions of targets and update the high-speed ROIs without interrupting acquisition. In this way the camera is capable of imaging moving targets at high-speed while simultaneously imaging the whole frame at a lower speed. We have used this camera system to monitor the heartbeat and blood cell flow of a water flea (Daphnia) at frame rates in excess of 1500 fps. PMID:22028852
Does aspartic acid racemization constrain the depth limit of the subsurface biosphere?
Onstott, T C; Magnabosco, C; Aubrey, A D; Burton, A S; Dworkin, J P; Elsila, J E; Grunsfeld, S; Cao, B H; Hein, J E; Glavin, D P; Kieft, T L; Silver, B J; Phelps, T J; van Heerden, E; Opperman, D J; Bada, J L
2014-01-01
Previous studies of the subsurface biosphere have deduced average cellular doubling times of hundreds to thousands of years based upon geochemical models. We have directly constrained the in situ average cellular protein turnover or doubling times for metabolically active micro-organisms based on cellular amino acid abundances, D/L values of cellular aspartic acid, and the in vivo aspartic acid racemization rate. Application of this method to planktonic microbial communities collected from deep fractures in South Africa yielded maximum cellular amino acid turnover times of ~89 years for 1 km depth and 27 °C and 1-2 years for 3 km depth and 54 °C. The latter turnover times are much shorter than previously estimated cellular turnover times based upon geochemical arguments. The aspartic acid racemization rate at higher temperatures yields cellular protein doubling times that are consistent with the survival times of hyperthermophilic strains and predicts that at temperatures of 85 °C, cells must replace proteins every couple of days to maintain enzymatic activity. Such a high maintenance requirement may be the principal limit on the abundance of living micro-organisms in the deep, hot subsurface biosphere, as well as a potential limit on their activity. The measurement of the D/L of aspartic acid in biological samples is a potentially powerful tool for deep, fractured continental and oceanic crustal settings where geochemical models of carbon turnover times are poorly constrained. Experimental observations on the racemization rates of aspartic acid in living thermophiles and hyperthermophiles could test this hypothesis. The development of corrections for cell wall peptides and spores will be required, however, to improve the accuracy of these estimates for environmental samples. © 2013 John Wiley & Sons Ltd.
Problem and pathological gambling in a sample of casino patrons.
Fong, Timothy W; Campos, Michael D; Brecht, Mary-Lynn; Davis, Alice; Marco, Adrienne; Pecanha, Viviane; Rosenthal, Richard J
2011-03-01
Relatively few studies have examined gambling problems among individuals in a casino setting. The current study sought to examine the prevalence of gambling problems among a sample of casino patrons and examine alcohol and tobacco use, health status, and quality of life by gambling problem status. To these ends, 176 casino patrons were recruited by going to a Southern California casino and requesting that they complete an anonymous survey. Results indicated the following lifetime rates for at-risk, problem, and pathological gambling: 29.2, 10.7, and 29.8%. Differences were found with regards to gambling behavior, and results indicated higher rates of smoking among individuals with gambling problems, but not higher rates of alcohol use. Self-rated quality of life was lower among pathological gamblers relative to non-problem gamblers, but did not differ from at-risk or problem gamblers. Although subject to some limitations, our data support the notion of higher frequency of gambling problems among casino patrons and may suggest the need for increased interventions for gambling problems on-site at casinos.
Liu, Chao; Xue, Chundong; Chen, Xiaodong; Shan, Lei; Tian, Yu; Hu, Guoqing
2015-06-16
Viscoelasticity-induced particle migration has recently received increasing attention due to its ability to obtain high-quality focusing over a wide range of flow rates. However, its application is limited to low throughput regime since the particles can defocus as flow rate increases. Using an engineered carrier medium with constant and low viscosity and strong elasticity, the sample flow rates are improved to be 1 order of magnitude higher than those in existing studies. Utilizing differential focusing of particles of different sizes, here, we present sheathless particle/cell separation in simple straight microchannels that possess excellent parallelizability for further throughput enhancement. The present method can be implemented over a wide range of particle/cell sizes and flow rates. We successfully separate small particles from larger particles, MCF-7 cells from red blood cells (RBCs), and Escherichia coli (E. coli) bacteria from RBCs in different straight microchannels. The proposed method could broaden the applications of viscoelastic microfluidic devices to particle/cell separation due to the enhanced sample throughput and simple channel design.
Rindermann, Heiner; Becker, David; Coyle, Thomas R.
2016-01-01
Following Snyderman and Rothman (1987, 1988), we surveyed expert opinions on the current state of intelligence research. This report examines expert opinions on causes of international differences in student assessment and psychometric IQ test results. Experts were surveyed about the importance of culture, genes, education (quantity and quality), wealth, health, geography, climate, politics, modernization, sampling error, test knowledge, discrimination, test bias, and migration. The importance of these factors was evaluated for diverse countries, regions, and groups including Finland, East Asia, sub-Saharan Africa, Southern Europe, the Arabian-Muslim world, Latin America, Israel, Jews in the West, Roma (gypsies), and Muslim immigrants. Education was rated by N = 71 experts as the most important cause of international ability differences. Genes were rated as the second most relevant factor but also had the highest variability in ratings. Culture, health, wealth, modernization, and politics were the next most important factors, whereas other factors such as geography, climate, test bias, and sampling error were less important. The paper concludes with a discussion of limitations of the survey (e.g., response rates and validity of expert opinions). PMID:27047425
Kasmi, Mariam; Hamdi, Moktar; Trabelsi, Ismail
2017-01-01
Residual fermented dairy products resulting from process defects or from expired shelf life products are considered as waste. Thus, dairies wastewater treatment plants (WWTP) suffer high input effluents polluting load. In this study, fermented residuals separation from the plant wastewater is proposed. In the aim to meet the municipal WWTP input limits, a pretreatment combining physical-chemical and biological processes was investigated to reduce residual fermented dairy products polluting effect. Yoghurt (Y) and fermented milk products (RL) were considered. Raw samples chemical oxygen demand (COD) values were assessed at 152 and 246 g.L -1 for Y and RL products, respectively. Following the thermal coagulation, maximum removal rates were recorded at 80 °C. Resulting whey stabilization contributed to the removal rates enhance to reach 72% and 87% for Y and RL samples; respectively. Residual whey sugar content was fermented using Candida strains. Bacterial growth and strains degrading potential were discussed. C. krusei strain achieved the most important removal rates of 78% and 85% with Y and RL medium, respectively. Global COD removal rates exceeded 93%.
ERIC Educational Resources Information Center
Robbins, Leslie K.; Hoke, Mary M.
2010-01-01
Perceptions of counselors from Hispanic serving high schools regarding professional nursing as a career have received limited study. A cross-sectional descriptive study of a convenience sample of 55 guidance counselors from Hispanic serving institutions identified the number of requests/referrals to nursing programs and perceptions of prospective…
ERIC Educational Resources Information Center
Yu, Jiang; Williford, William R.
1991-01-01
Used sample from New York State Driver License File to mathematically extend dimension of file so that data purging procedure exerts minimum influence on calculation of drinking-driving recidivism. Examined impact of dimension of data on recidivism rate and mathematically extended file until impact of data dimension was minimum. Calculated New…
ERIC Educational Resources Information Center
Parish, Susan L.; Saville, Alison Whisnant
2006-01-01
Using data from the Medical Expenditure Panel Survey for 2000 and 2002, we compared potential and realized use of health care for a national sample of working-age women with cognitive disabilities. Despite having similar likelihoods of potential access to health care as compared to nondisabled women, they had markedly worse rates of receiving…
Linking landscape-scale differences in forage to ungulate nutritional ecology.
Proffitt, Kelly M; Hebblewhite, Mark; Peters, Wibke; Hupp, Nicole; Shamhart, Julee
2016-10-01
Understanding how habitat and nutritional condition affect ungulate populations is necessary for informing management, particularly in areas experiencing carnivore recovery and declining ungulate population trends. Variations in forage species availability, plant phenological stage, and the abundance of forage make it challenging to understand landscape-level effects of nutrition on ungulates. We developed an integrated spatial modeling approach to estimate landscape-level elk (Cervus elaphus) nutritional resources in two adjacent study areas that differed in coarse measures of habitat quality and related the consequences of differences in nutritional resources to elk body condition and pregnancy rates. We found no support for differences in dry matter digestibility between plant samples or in phenological stage based on ground sampling plots in the two study areas. Our index of nutritional resources, measured as digestible forage biomass, varied among land cover types and between study areas. We found that altered plant composition following fires was the biggest driver of differences in nutritional resources, suggesting that maintaining a mosaic of fire history and distribution will likely benefit ungulate populations. Study area, lactation status, and year affected fall body fat of adult female elk. Elk in the study area exposed to lower summer range nutritional resources had lower nutritional condition entering winter. These differences in nutritional condition resulted in differences in pregnancy rate, with average pregnancy rates of 89% for elk exposed to higher nutritional resources and 72% for elk exposed to lower nutritional resources. Summer range nutritional resources have the potential to limit elk pregnancy rate and calf production, and these nutritional limitations may predispose elk to be more sensitive to the effects of harvest or predation. Wildlife managers should identify ungulate populations that are nutritionally limited and recognize that these populations may be more impacted by recovering carnivores or harvest than populations inhabiting more productive summer habitats. © 2016 by the Ecological Society of America.
Rotenone persistence in freshwater ponds: Effects of temperature and sediment adsorption
Dawson, V.K.; Gingerich, W.H.; Davis, R.A.; Gilderhus, P.A.
1991-01-01
The persistence of rotenone was compared between a cement-lined pond (0.04 hectare) and an earthen-bottom pond (0.02 hectare) treated with 5 I?L Noxfish/L (250 I?g rotenone/L) during spring, summer, and fall. Water temperatures on the days of treatment in each season were 8, 22, and 15A?C, respectively. Both ponds were filled with pond water from a common source 1 week before each of the three treatments. Water samples (filtered and unfiltered) and sediment samples were analyzed by high-performance liquid chromatography to monitor the decrease of rotenone until residues were at or below the detection limit (<2.0 I?g/L for water and < 25 ng/g for sediments). The loss of rotenone from water generally followed a first-order rate ofdecay. Rotenone disappeared two to three times faster in the earthen pond than in the concrete pond. The rotenone half-life times in the spring, summer, and fall treatments were 3.7, 1.3, and 5.2 d, respectively, in the concrete pond, and 1.8, 0.7, and 1.8 d in the earthen pond. Rates of decay in both ponds were directly correlated with water temperature. Filtered water samples from both ponds contained less rotenone than unfiltered water, indicating that some rotenone was bound to suspended material. The highest concentration of rotenone in sediment samples was 102 ng/g; residues decreased to below the detection limit within 14 d in the spring treatment and within 3 d in the summer and fall treatments.
Pharmacokinetics and pharmacodynamics of detomidine following sublingual administration to horses.
Dimaio Knych, Heather K; Stanley, Scott D
2011-10-01
To characterize pharmacokinetics and pharmacodynamics of detomidine gel administered sublingually in accordance with label instructions to establish appropriate withdrawal guidelines for horses before competition. 12 adult racehorses. Horses received a single sublingual administration of 0.04 mg of detomidine/kg. Blood samples were collected before and up to 72 hours after drug administration. Urine samples were collected for 5 days after detomidine administration. Plasma and urine samples were analyzed via liquid chromatography-mass spectrometry, and resulting data were analyzed by use of noncompartmental analysis. Chin-to-ground distance, heart rate and rhythm, glucose concentration, PCV, and plasma protein concentration were also assessed following detomidine administration. Mean ± SD terminal elimination half-life of detomidine was 1.5 ± 1 hours. Metabolite concentrations were below the limit of detection (0.02, 0.1, and 0.5 ng/mL for detomidine, carboxydetomidine, and hydroxydetomidine, respectively) in plasma by 24 hours. Concentrations of detomidine and its metabolites were below the limit of detection (0.05 ng/mL for detomidine and 0.10 ng/mL for carboxydetomidine and hydroxydetomidine) in urine by 3 days. All horses had various degrees of sedation after detomidine administration. Time of onset was ≤ 40 minutes, and duration of sedation was approximately 2 hours. Significant decreases, relative to values at time 0, were detected for chin-to-ground distance and heart rate. There was an increased incidence and exacerbation of preexisting atrioventricular blocks after detomidine administration. A 48-hour and 3-day withdrawal period for detection in plasma and urine samples, respectively, should be adopted for sublingual administration of detomidine gel.
NASA Astrophysics Data System (ADS)
Lahiri, B. B.; Ranoo, Surojit; Muthukumaran, T.; Philip, John
2018-04-01
The effects of initial susceptibility and size polydispersity on magnetic hyperthermia efficiency in two water based ferrofluids containing phosphate and TMAOH coated superparamagnetic Fe3O4 nanoparticles were studied. Experiments were performed at a fixed frequency of 126 kHz on four different concentrations of both samples and under different external field amplitudes. It was observed that for field amplitudes beyond 45.0 kAm-1, the maximum temperature rise was in the vicinity of 42°C (hyperthermia limit) which indicated the suitability of the water based ferrofluids for hyperthermia applications. The maximum temperature rise and specific absorption rate were found to vary linearly with square of the applied field amplitudes, in accordance with theoretical predictions. It was further observed that for a fixed sample concentration, specific absorption rate was higher for the phosphate coated samples which was attributed to the higher initial static susceptibility and lower size polydispersity of phosphate coated Fe3O4.
Michaud, Jean-Philippe; Moreau, Gaétan
2013-07-01
Experimental protocols in forensic entomology successional field studies generally involve daily sampling of insects to document temporal changes in species composition on animal carcasses. One challenge with that method has been to adjust the sampling intensity to obtain the best representation of the community present without affecting the said community. To this date, little is known about how such investigator perturbations affect decomposition-related processes. Here, we investigated how different levels of daily sampling of fly eggs and fly larvae affected, over time, carcass decomposition rate and the carrion insect community. Results indicated that a daily sampling of <5% of the egg and larvae volumes present on a carcass, a sampling intensity believed to be consistent with current accepted practices in successional field studies, had little effect overall. Higher sampling intensities, however, slowed down carcass decomposition, affected the abundance of certain carrion insects, and caused an increase in the volume of eggs laid by dipterans. This study suggests that the carrion insect community not only has a limited resilience to recurrent perturbations but that a daily sampling intensity equal to or <5% of the egg and larvae volumes appears adequate to ensure that the system is representative of unsampled conditions. Hence we propose that this threshold be accepted as best practice in future forensic entomology successional field studies.
Understanding heart rate alarm adjustment in the intensive care units through an analytical approach
Pelter, Michele M.; Drew, Barbara J.; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J. Matt; Hu, Xiao
2017-01-01
Background Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. Objectives To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Methods Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). Results There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). Conclusions HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision. PMID:29176776
NASA Astrophysics Data System (ADS)
Beganskas, S.; Gorski, G.; Fisher, A. T.; Weir, W. B.; Schmidt, C. M.; Saltikov, C.; Stoneburner, B.; Hernandez, J.; Harmon, R. E.; Weathers, T. S.
2016-12-01
We have designed field experiments to observe and quantify water quality improvement during infiltration in the shallow subsurface, as part of managed aquifer recharge (MAR). We are exploring how microbial diversity and denitrification rate respond to different infiltration rates and the presence or absence of carbon-rich reactive materials (woodchips or biochar). In 2015, we conducted a series of two-week-long field infiltration tests, and in 2016 we are running tests at a new site. For each test, nitrate-rich water (20-25 ppm NO3-N) was continuously applied to 1-m square plots instrumented to measure infiltration rates and sample subsurface water at multiple depths. Soil samples were collected before and after each test to assess microbial diversity. In 2015, we observed infiltration rates of 4-18 m/d, consistent with very sandy soils at our field site. All water samples had >20 ppm DOC, indicating that denitrification was unlikely carbon-limited. There was a net increase in DOC in fluids sampled below woodchips, but no change in DOC in samples from un-amended native soil. Up to 20% of NO3- was removed below woodchips on days with infiltration rates below 15 m/d. Nitrate removal was not observed in native soil, even though infiltration rates were considerably lower, 4 m/d. Isotopic analyses indicate that denitrification is likely the mechanism for nitrate removal. Genomic sequencing of soil microbes shows that microbial populations' relative abundance shifted significantly due to infiltration; further analyses are underway. Our results suggest that rapid infiltration can lead to oxic conditions unfavorable for denitrification, and that a carbon-rich reactive material (woodchips) may stimulate microbially-mediated denitrification. Our experimental design is a novel way to examine factors that impact water quality during infiltration. Nitrate, a pervasive groundwater contaminant, can be removed via denitrification during MAR under some conditions, depending on infiltration rate, available carbon, and substrate material. Our work has applications for designing MAR systems that effectively improve water supply and water quality.
Measuring Flow Rate in Crystalline Bedrock Wells Using the Dissolved Oxygen Alteration Method.
Vitale, Sarah A; Robbins, Gary A
2017-07-01
Determination of vertical flow rates in a fractured bedrock well can aid in planning and implementing hydraulic tests, water quality sampling, and improving interpretations of water quality data. Although flowmeters are highly accurate in flow rate measurement, the high cost and logistics may be limiting. In this study the dissolved oxygen alteration method (DOAM) is expanded upon as a low-cost alternative to determine vertical flow rates in crystalline bedrock wells. The method entails altering the dissolved oxygen content in the wellbore through bubbler aeration, and monitoring the vertical advective movement of the dissolved oxygen over time. Measurements were taken for upward and downward flows, and under ambient and pumping conditions. Vertical flow rates from 0.06 to 2.30 Lpm were measured. To validate the method, flow rates determined with the DOAM were compared to pump discharge rates and found to be in agreement within 2.5%. © 2017, National Ground Water Association.
Caffaro-Filho, Roberto A.; Wong, Mayee; Harwood, Valerie J.; Moravcik, Philip; Fujioka, Roger S.
2016-01-01
ABSTRACT Identification of sources of fecal contaminants is needed to (i) determine the health risk associated with recreational water use and (ii) implement appropriate management practices to mitigate this risk and protect the environment. This study evaluated human-associated Bacteroides spp. (HF183TaqMan) and human polyomavirus (HPyV) markers for host sensitivity and specificity using human and animal fecal samples collected in Hawaii. The decay rates of those markers and indicator bacteria were identified in marine and freshwater microcosms exposed and not exposed to sunlight, followed by field testing of the usability of the molecular markers. Both markers were strongly associated with sewage, although the cross-reactivity of the HF183TaqMan (also present in 82% of canine [n = 11], 30% of mongoose [n = 10], and 10% of feline [n = 10] samples) needs to be considered. Concentrations of HF183TaqMan in human fecal samples exceeded those in cross-reactive animals at least 1,000-fold. In the absence of sunlight, the decay rates of both markers were comparable to the die-off rates of enterococci in experimental freshwater and marine water microcosms. However, in sunlight, the decay rates of both markers were significantly lower than the decay rate of enterococci. While both markers have their individual limitations in terms of sensitivity and specificity, these limitations can be mitigated by using both markers simultaneously; ergo, this study supports the concurrent use of HF183TaqMan and HPyV markers for the detection of sewage contamination in coastal and inland waters in Hawaii. IMPORTANCE This study represents an in-depth characterization of microbial source tracking (MST) markers in Hawaii. The distribution and concentrations of HF183TaqMan and HPyV markers in human and animal fecal samples and in wastewater, coupled with decay data obtained from sunlight-exposed and unexposed microcosms, support the concurrent application of HF183TaqMan and HPyV markers for sewage contamination detection in Hawaii waters. Both markers are more conservative and more specific markers of sewage than fecal indicator bacteria (enterococci and Escherichia coli). Analysis of HF183TaqMan (or newer derivatives) is recommended for inclusion in future epidemiological studies concerned with beach water quality, while better concentration techniques are needed for HPyV. Such epidemiological studies can be used to develop new recreational water quality criteria, which will provide direct information on the absence or presence of sewage contamination in water samples as well as reliable measurements of the risk of waterborne disease transmission to swimmers. PMID:27613686
Young, Dmitri A; Neylan, Thomas C; O'Donovan, Aoife; Metzler, Thomas; Richards, Anne; Ross, Jessica A; Inslicht, Sabra S
2018-08-01
While the BDNF Val66Met polymorphism has been linked to various psychological disorders, limited focus has been on its relationship to posttraumatic stress disorder (PTSD) and early traumas such as child abuse. Therefore, we assessed whether Val66Met was associated with fear potentiated psychophysiological response and HPA axis dysfunction and whether PTSD status or child abuse history moderated these outcomes in a sample of Veterans. 226 and 173 participants engaged in a fear potentiated acoustic startle paradigm and a dexamethasone suppression test (DST) respectively. Fear conditions included no, ambiguous, and high threat conditions. Psychophysiological response measures included electromyogram (EMG), skin conductance response (SCR), and heart rate. The Clinician Administered PTSD Scale (CAPS) and the Trauma History Questionnaire (THQ) were used to assess PTSD status and child abuse history respectively. Met allele carriers exhibited greater SCR magnitudes in the no and ambiguous threat conditions (p < 0.01 and p < 0.05 respectively). Met carriers with PTSD exhibited greater physiological response magnitudes in the ambiguous (SCR, p < 0.001) and high threat conditions (SCR and heart rate, both p ≤ 0.005). Met carrier survivors of child abuse exhibited blunted heart rate magnitudes in the high threat condition (p < 0.01). Met allele carries with PTSD also exhibited greater percent cortisol suppression (p < 0.005). Limitations included small sample size and the cross-sectional nature of the data. The Val66met may impact PTSD susceptibility differentially via enhanced threat sensitivity and HPA axis dysregulation. Child abuse may moderate Val66Met's impact on threat reactivity. Future research should explore how neuronal mechanisms might mediate this risk. Published by Elsevier B.V.
Shi, Jiachun; Yu, Xiulin; Zhang, Mingkui; Lu, Shenggao; Wu, Weihong; Wu, Jianjun; Xu, Jianming
2011-01-01
Heavy metal (copper [Cu], zinc [Zn], and cadmium [Cd]) pollution of soils from pig manures in soil-rice ( L.) systems under intensive farming was investigated, taking Nanhu, China, as the case study area. Two hundred pig manures and 154 rice straws, brown rice samples, and corresponding surface soil (0-15 cm) samples were collected in paddy fields from 150 farms in 16 major villages within the study area. The mean Cu and Zn concentrations in pig manures consistently exceeded the related standard. About 44 and 60% of soil samples exceed the Chinese Soil Cu and Cd Environmental Quality Standards, respectively. The concentration of Cu, Zn, and Cd in brown rice did not exceed the Chinese Food Hygiene Standard. There was a significant positive correlation between total Cu and Zn contents in soil and application rate of pig manures. Strong correlation was observed between the extractable Cu, Zn, and Cd in soil and the Cu, Zn, and Cd contents in the brown rice. The spatial distribution maps of Cu and Zn concentrations in brown rice, straw, and extractable soil Cu and Zn concentration also showed similar geographical trends. Further analyses on heavy metals loading flux and accumulation rates from pig manure applied suggested that Cu and Cd contents in soil currently have already exceeded the maximum permissible limit, and Zn, if still at current manure application rates, will reach the ceiling concentration limits in 9 yr. This study assists in understanding the risk of heavy metals accumulating from pig manure applications to agricultural soils. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Self-perception of disability and prospects for employment among U.S. veterans.
Griffin, Christopher L; Stein, Michael Ashley
2015-01-01
Barriers to employment in the civilian labor force are increasingly difficult problems for returning veterans with disabilities. Reduced self-perception of disability status because of predominant military norms can be particularly harmful to reintegration efforts. We analyze rates of self-identified and externally determined disability status among U.S. veterans. Evidence of a lower self-report rate would confirm the hypothesis that armed forces culture might hold back truly deserving veterans from seeking the benefits owed, including specialized employment training programs. We use data from the Current Population Survey Veterans Supplement over the sample period 1995-2010 on disability status and associated demographic characteristics to present descriptive measures and limited statistical inference. Over the entire sample period, federal agencies considered 29% of the survey respondents to have a service-connected disability versus a 9% self-identification rate. The rate of more severe service-connected disabilities has risen steadily, while less drastic disability rates have fallen. Non-white respondents and those with lower education levels were less likely to self-identify. Large disparities in internal and external disability status identification raise questions about targeting soldiers re-entering the labor force. Employment policy should focus on overcoming negative cultural stereotypes and encouraging self-identification.
Burdick, Summer M.; Wilkens, Alexander X.; VanderKooi, Scott P.
2008-01-01
We continued sampling juvenile suckers in 2006 as part of an effort to develop bioenergetics models for juvenile Lost River and shortnose suckers. This study required us to collect fish to determine growth rates and energy content of juvenile suckers. We followed the sampling protocols and methods described by Hendrixson et al. (2007b) to maintain continuity and facilitate comparisons with data collected in recent years, but sampled at a reduced level of effort compared to previous years (approximately one-third) due to limited funding. Here we present a summary of catch data collected in 2006. Bioenergetics models will be reported separately
Laboratory formation of non-cementing, methane hydrate-bearing sands
Waite, William F.; Bratton, Peter M.; Mason, David H.
2011-01-01
Naturally occurring hydrate-bearing sands often behave as though methane hydrate is acting as a load-bearing member of the sediment. Mimicking this behavior in laboratory samples with methane hydrate likely requires forming hydrate from methane dissolved in water. To hasten this formation process, we initially form hydrate in a free-gas-limited system, then form additional hydrate by circulating methane-supersaturated water through the sample. Though the dissolved-phase formation process can theoretically be enhanced by increasing the pore pressure and flow rate and lowering the sample temperature, a more fundamental concern is preventing clogs resulting from inadvertent methane bubble formation in the circulation lines. Clog prevention requires careful temperature control throughout the circulation loop.
Scalable boson sampling with time-bin encoding using a loop-based architecture.
Motes, Keith R; Gilchrist, Alexei; Dowling, Jonathan P; Rohde, Peter P
2014-09-19
We present an architecture for arbitrarily scalable boson sampling using two nested fiber loops. The architecture has fixed experimental complexity, irrespective of the size of the desired interferometer, whose scale is limited only by fiber and switch loss rates. The architecture employs time-bin encoding, whereby the incident photons form a pulse train, which enters the loops. Dynamically controlled loop coupling ratios allow the construction of the arbitrary linear optics interferometers required for boson sampling. The architecture employs only a single point of interference and may thus be easier to stabilize than other approaches. The scheme has polynomial complexity and could be realized using demonstrated present-day technologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quarles, C. Derrick; Carado, Anthony J.; Barinaga, Charles J.
2012-01-01
A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary andmore » a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.« less
Outcome quality standards in pancreatic oncologic surgery in Spain.
Sabater, Luis; Mora, Isabel; Gámez Del Castillo, Juan Manuel; Escrig-Sos, Javier; Muñoz-Forner, Elena; Garcés-Albir, Marina; Dorcaratto, Dimitri; Ortega, Joaquín
2018-05-18
To establish quality standards in oncologic surgery is a complex but necessary challenge to improve surgical outcomes. Unlike other tumors, there are no well-defined quality standards in pancreatic cancer. The aim of this study is to identify quality indicators in pancreatic oncologic surgery in Spain as well as their acceptable limits of variability. Quality indicators were selected based on clinical practice guidelines, consensus conferences, reviews and national publications on oncologic pancreatic surgery between the years 2000 and 2016. Variability margins for each indicator have been determined by statistical process control techniques and graphically represented with the 99.8 and 95% confidence intervals above and below the weighted average according to sample size. The following indicators have been determined with their weighted average and acceptable quality limits: resectability rate 71% (>58%), morbidity 58% (<73%), mortality 4% (<10%), biliary leak 6% (<14%), pancreatic fistula rate 18% (<29%), hemorrhage 11% (<21%), reoperation rate 11% (<20%) and mean hospital stay (<21 days). To date, few related series have been published, and they present important methodological limitations. Among the selected indicators, the morbidity and mortality quality limits have come out higher than those obtained in international standards. It is necessary for Spanish pancreatic surgeons to adopt homogeneous criteria regarding indicators and their definitions to allow for the comparison of their results. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Sequential injection spectrophotometric determination of oxybenzone in lipsticks.
Salvador, A; Chisvert, A; Camarasa, A; Pascual-Martí, M C; March, J G
2001-08-01
A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. Ethanol was also used as carrier in the SI system. Seventy-two injections per hour can be performed, which means a sample frequency of 24 h(-1) if three replicates are measured for each sample.
Injury rates and injury risk factors among U.S. Army wheel vehicle mechanics.
Knapik, Joseph J; Jones, Sarah B; Darakjy, Salima; Hauret, Keith G; Bullock, Steven H; Sharp, Marilyn A; Jones, Bruce H
2007-09-01
This study describes injury rates, injury diagnoses, anatomical locations of injuries, limited duty days, and activities associated with injuries in a sample of Army mechanics. Medical records of 518 male and 43 female Army mechanics were screened for injuries during 1 year at a large U.S. Army installation. Weight, height, age, and ethnicity were also extracted from the medical records. Body mass index was calculated as weight/height2. Overall injury rates for men and women were 124 and 156 injuries/100 person-years, respectively, with a rate of 127 injuries/100 person-years for all soldiers combined. Women had higher overuse injury rates while men had higher traumatic injury rates. Limited duty days for men and women were 2,076 and 1,966 days/100 person-years, respectively. The lower back, knee, ankle, foot, and shoulder involved 61% of the injuries. Activities associated with injury included (in order of incidence) physical training, mechanical work, sports, airborne-related activities, road marching, garrison/home activities, and chronic conditions. Among the men, elevated injury risk was associated with higher body weight and higher body mass index. It may be possible to prevent many injuries by implementation of evidenced-based interventions currently available in the literature.
Effects of Engineered Wettability on the Efficiency of Dew Collection.
Gerasopoulos, Konstantinos; Luedeman, William L; Ölçeroglu, Emre; McCarthy, Matthew; Benkoski, Jason J
2018-01-31
Surface wettability plays an important role in dew collection. Nucleation is faster on hydrophilic surfaces, while droplets slide more readily on hydrophobic surfaces. Plants and animals in coastal desert environments appear to overcome this trade-off through biphilic surfaces with patterned wettability. In this study, we investigate the effects of millimeter-scale wettability patterns, mimicking those of the Stenocara beetle, on the rate of water collection from humid air. The rate of water collection per unit area is measured as a function of subcooling (ΔT = 1, 7, and 27 °C) and angle of inclination (from 10° to 90°). It is then compared for superbiphilic, hydrophilic, hydrophobic, and surperhydrophobic surfaces. For large subcooling, neither wettability nor tilt angle has a significant effect because the rate of condensation is so great. For 1 °C subcooling and large angles, hydrophilic surfaces perform best because condensation is the rate-limiting step. For low angles of inclination, superhydrophobic samples are best because droplet sliding is the rate-limiting step. Superbiphilic surfaces, in contrast to their superior fog collecting capabilities, generally collected dew at the slowest rate due to their inherent contact angle hysteresis. Theoretical considerations suggest that this finding may apply more generally to surfaces with patterned wettability.
Lindvall Dahlgren, Camilla; Wisting, Line; Rø, Øyvind
2017-01-01
The objective of this study was to systematically review the literature on the prevalence of eating disorders (EDs) during the DSM-5 era, and to report rates of point- and lifetime prevalence. A PubMed search was conducted targeting articles on the epidemiology of EDs, in particular, reported rates of prevalence. The review was performed in accordance with PRISMA guidelines, and was limited to DSM-5 based eating disorder diagnoses published between 2012 and 2017. A total of 19 studies fulfilled inclusion criteria and were included in the study. Following the transition to DSM-5, it is evident that the prevalence of eating disorder not otherwise specified (EDNOS)/other specified feeding and eating disorders (OSFED) has decreased as intended, and there is preliminary evidence suggesting that rates of anorexia nervosa (AN) and bulimia nervosa (BN) and binge eating disorder (BED) have increased. Further, we observed higher rates of BED prevalence among females compared to males, with rates increasing with age. A limitation to the study was the search date, and that none of the included studies investigated the "new" DSM-5 feeding disorders avoidant restrictive food intake disorder (ARFID), pica or rumination disorder warranting attention in future studies investigating the epidemiology of feeding and eating disorders.
Determining Aliasing in Isolated Signal Conditioning Modules
NASA Technical Reports Server (NTRS)
2009-01-01
The basic concept of aliasing is this: Converting analog data into digital data requires sampling the signal at a specific rate, known as the sampling frequency. The result of this conversion process is a new function, which is a sequence of digital samples. This new function has a frequency spectrum, which contains all the frequency components of the original signal. The Fourier transform mathematics of this process show that the frequency spectrum of the sequence of digital samples consists of the original signal s frequency spectrum plus the spectrum shifted by all the harmonics of the sampling frequency. If the original analog signal is sampled in the conversion process at a minimum of twice the highest frequency component contained in the analog signal, and if the reconstruction process is limited to the highest frequency of the original signal, then the reconstructed signal accurately duplicates the original analog signal. It is this process that can give birth to aliasing.
Creep of quartz by dislocation and grain boundary processes
NASA Astrophysics Data System (ADS)
Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.
2015-12-01
Wet polycrystalline quartz aggregates deformed at temperatures T of 600°-900°C and strain rates of 10-4-10-6 s-1 at a confining pressure Pc of 1.5 GPa exhibit plasticity at low T, governed by dislocation glide and limited recovery, and grain size-sensitive creep at high T, governed by diffusion and sliding at grain boundaries. Quartz aggregates were HIP-synthesized, subjecting natural milky quartz powder to T=900°C and Pc=1.5 GPa, and grain sizes (2 to 25 mm) were varied by annealing at these conditions for up to 10 days. Infrared absorption spectra exhibit a broad OH band at 3400 cm-1 due to molecular water inclusions with a calculated OH content (~4000 ppm, H/106Si) that is unchanged by deformation. Rate-stepping experiments reveal different stress-strain rate functions at different temperatures and grain sizes, which correspond to differing stress-temperature sensitivities. At 600-700°C and grain sizes of 5-10 mm, flow law parameters compare favorably with those for basal plasticity and dislocation creep of wet quartzites (effective stress exponents n of 3 to 6 and activation enthalpy H* ~150 kJ/mol). Deformed samples show undulatory extinction, limited recrystallization, and c-axis maxima parallel to the shortening direction. Similarly fine-grained samples deformed at 800°-900°C exhibit flow parameters n=1.3-2.0 and H*=135-200 kJ/mol corresponding to grain size-sensitive Newtonian creep. Deformed samples show some undulatory extinction and grain sizes change by recrystallization; however, grain boundary deformation processes are indicated by the low value of n. Our experimental results for grain size-sensitive creep can be compared with models of grain boundary diffusion and grain boundary sliding using measured rates of silicon grain boundary diffusion. While many quartz mylonites show microstructural and textural evidence for dislocation creep, results for grain size-sensitive creep may apply to very fine-grained (<10 mm) quartz mylonites.
A novel inexpensive IV catheterization training model for paramedic students.
Parwani, Vivek; Cone, David C
2006-01-01
Teaching paramedic students venipuncture and intravenous catheterization has traditionally relied on bulky, expensive phlebotomy models. A gelatin intravenous model (GIM) costing less than 50 cents is currently being used in the training of medical students and interns. The study objective was to evaluate paramedic students' perceptions of the GIM as a training tool. GIMs are created using gelatin, psyllium, Penrose drains, food coloring, salt, and water. Penrose drains are filled with artificial blood composed of salt water and food coloring. The drains are placed in an aluminum pan with a base of hardening gelatin, with half-inch drains at the bottom of the pan and quarter-inch drains higher up in layers of mixed psyllium and gelatin to simulate deep and superficial veins respectively. A convenience, volunteer sample of 14 paramedic students who previously trained with traditional phlebotomy models each made two to five attempts at intravenous insertion using the GIM. Perceptions of the GIM were measured using a Likert scale (1, worst rating; 5, best rating). Means are reported. Study subjects rated ease of use at 4.17, realism at 4.07, and effectiveness in learning intravenous insertion at 4.28. GIM as a more effective teaching tool than the conventional rubber arm yielded a rating of 4.14. This study is limited by a small sample size, and further studies evaluating the GIMs construct and content validity are needed. Despite these limitations, given the GIMs simplicity and value, paramedic instructors may wish to consider implementation of this device in their training programs.
Pyen, Grace S.; Browner, Richard F.; Long, Stephen
1986-01-01
A fixed-size simplex has been used to determine the optimum conditions for the simultaneous determination of arsenic, selenium, and antimony by hydride generation and inductively coupled plasma emission spectrometry. The variables selected for the simplex were carrier gas flow rate, rf power, viewing height, and reagent conditions. The detection limit for selenium was comparable to the preoptimized case, but there were twofold and fourfold improvements in the detection limits for arsenic and antimony, respectively. Precision of the technique was assessed with the use of artificially prepared water samples.
Migration intentions and illicit substance use among youth in central Mexico.
Marsiglia, Flavio Francisco; Kulis, Stephen; Hoffman, Steven; Calderón-Tena, Carlos Orestes; Becerra, David; Alvarez, Diana
2011-01-01
This study explored intentions to emigrate and substance use among youth (ages 14-24) from a central Mexico state with high emigration rates. Questionnaires were completed in 2007 by 702 students attending a probability sample of alternative secondary schools serving remote or poor communities. Linear and logistic regression analyses indicated that stronger intentions to emigrate predicted greater access to drugs, drug offers, and use of illicit drugs (marijuana, cocaine, inhalants), but not alcohol or cigarettes. Results are related to the healthy migrant theory and its applicability to youth with limited educational opportunities. The study's limitations are noted.
Low-Dead-Volume Inlet for Vacuum Chamber
NASA Technical Reports Server (NTRS)
Naylor, Guy; Arkin, C.
2010-01-01
Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead -volume. As a result, a high -vacuum gas inlet was developed with low dead -volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.
Low-Dead-Volume Inlet for Vacuum Chamber
NASA Technical Reports Server (NTRS)
Naylor, Guy; Arkin, C.
2011-01-01
Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead-volume. As a result, a high-vacuum gas inlet was developed with low dead-volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.
NASA Astrophysics Data System (ADS)
Knudsen, Mads Faurschou; Egholm, David Lundbek
2018-02-01
Paired cosmogenic nuclides are often used to constrain the exposure/burial history of landforms repeatedly covered by ice during the Quaternary, including tors, high-elevation surfaces, and steep alpine summits in the circum-Arctic regions. The approach generally exploits the different production rates and half-lives of 10Be and 26Al to infer past exposure/burial histories. However, the two-stage minimum-limiting exposure and burial model regularly used to interpret the nuclides ignores the effect of variable erosion rates, which potentially may bias the interpretation. In this study, we use a Monte Carlo model approach to investigate systematically how the exposure/burial and erosion history, including variable erosion and the timing of erosion events, influence concentrations of 10Be and 26Al. The results show that low 26Al/10Be ratios are not uniquely associated with prolonged burial under ice, but may as well reflect ice covers that were limited to the coldest part of the late Pleistocene combined with recent exhumation of the sample, e.g. due to glacial plucking during the last glacial period. As an example, we simulate published 26Al/10Be data from Svalbard and show that it is possible that the steep alpine summits experienced ice-free conditions during large parts of the late Pleistocene and varying amounts of glacial erosion. This scenario, which contrasts with the original interpretation of more-or-less continuous burial under non-erosive ice over the last ∼1 Myr, thus challenge the conventional interpretation of such data. On the other hand, high 26Al/10Be ratios do not necessarily reflect limited burial under ice, which is the common interpretation of high ratios. In fact, high 26Al/10Be ratios may also reflect extensive burial under ice, combined with a change from burial under erosive ice, which brought the sample close to the surface, to burial under non-erosive ice at some point during the mid-Pleistocene. Importantly, by allowing for variable erosion rates, the model results may reconcile spatially varying 26Al/10Be data from bedrock surfaces preserved over multiple glacial cycles, suggesting that samples from the same high-elevation surface or neighbouring alpine summits may have experienced similar long-term burial under ice, but varying amounts of glacial erosion.
A Theoretical Basis for Entropy-Scaling Effects in Human Mobility Patterns
2016-01-01
Characterizing how people move through space has been an important component of many disciplines. With the advent of automated data collection through GPS and other location sensing systems, researchers have the opportunity to examine human mobility at spatio-temporal resolution heretofore impossible. However, the copious and complex data collected through these logging systems can be difficult for humans to fully exploit, leading many researchers to propose novel metrics for encapsulating movement patterns in succinct and useful ways. A particularly salient proposed metric is the mobility entropy rate of the string representing the sequence of locations visited by an individual. However, mobility entropy rate is not scale invariant: entropy rate calculations based on measurements of the same trajectory at varying spatial or temporal granularity do not yield the same value, limiting the utility of mobility entropy rate as a metric by confounding inter-experimental comparisons. In this paper, we derive a scaling relationship for mobility entropy rate of non-repeating straight line paths from the definition of Lempel-Ziv compression. We show that the resulting formulation predicts the scaling behavior of simulated mobility traces, and provides an upper bound on mobility entropy rate under certain assumptions. We further show that this formulation has a maximum value for a particular sampling rate, implying that optimal sampling rates for particular movement patterns exist. PMID:27571423
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, J; Velsko, S
This report explores the question of whether meaningful conclusions can be drawn regarding the transmission relationship between two microbial samples on the basis of differences observed between the two sample's respective genomes. Unlike similar forensic applications using human DNA, the rapid rate of microbial genome evolution combined with the dynamics of infectious disease require a shift in thinking on what it means for two samples to 'match' in support of a forensic hypothesis. Previous outbreaks for SARS-CoV, FMDV and HIV were examined to investigate the question of how microbial sequence data can be used to draw inferences that link twomore » infected individuals by direct transmission. The results are counter intuitive with respect to human DNA forensic applications in that some genetic change rather than exact matching improve confidence in inferring direct transmission links, however, too much genetic change poses challenges, which can weaken confidence in inferred links. High rates of infection coupled with relatively weak selective pressure observed in the SARS-CoV and FMDV data lead to fairly low confidence for direct transmission links. Confidence values for forensic hypotheses increased when testing for the possibility that samples are separated by at most a few intermediate hosts. Moreover, the observed outbreak conditions support the potential to provide high confidence values for hypothesis that exclude direct transmission links. Transmission inferences are based on the total number of observed or inferred genetic changes separating two sequences rather than uniquely weighing the importance of any one genetic mismatch. Thus, inferences are surprisingly robust in the presence of sequencing errors provided the error rates are randomly distributed across all samples in the reference outbreak database and the novel sequence samples in question. When the number of observed nucleotide mutations are limited due to characteristics of the outbreak or the availability of only partial rather than whole genome sequencing, indel information was shown to have the potential to improve performance but only for select outbreak conditions. In examined HIV transmission cases, extended evolution proved to be the limiting factor in assigning high confidence to transmission links, however, the potential to correct for extended evolution not associated with transmission events is demonstrated. Outbreak specific conditions such as selective pressure (in the form of varying mutation rate), are shown to impact the strength of inference made and a Monte Carlo simulation tool is introduced, which is used to provide upper and lower bounds on the confidence values associated with a forensic hypothesis.« less
Woodhall, Sarah C; Nichols, Tom; Alexander, Sarah; da Silva, Filomeno Coelho; Mercer, Catherine H; Ison, Catherine; Gill, O Noel; Soldan, Kate
2015-09-01
Chlamydia prevalence in the general population is a potential outcome measure for the evaluation of chlamydia control programmes. We carried out a pilot study to determine the feasibility of using a postal survey for population-based chlamydia prevalence monitoring. Postal invitations were sent to a random sample of 2000 17-year-old to 18-year-old women registered with a general practitioner in two pilot areas in England. Recipients were randomised to receive either a self-sampling kit (n=1000), a self-sampling kit and offer of £5 voucher on return of sample (n=500) or a self-sampling kit on request (n=500). Participants returned a questionnaire and self-taken vulvovaginal swab sample for unlinked anonymous Chlamydia trachomatis testing. Non-responders were sent a reminder letter 3 weeks after initial invitation. We calculated the participation rate (number of samples returned/number of invitations sent) and cost per sample returned (including cost of consumables and postage) in each group. A total of 155/2000 (7.8%) samples were returned with consent for testing. Participation rates varied by invitation group: 7.8% in the group who were provided with a self-sampling kit, 14% in the group who were also offered a voucher and 1.0% in the group who were not sent a kit. The cost per sample received was lowest (£36) in the group who were offered both a kit and a voucher. The piloted survey methodology achieved low participation rates. This approach is not suitable for population-based monitoring of chlamydia prevalence among young women in England. (UKCRN ID 10913). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Pisupati; Wasco; Scaroni
2000-05-29
Results from a series of tests conducted to study the emission of polynuclear or polycyclic aromatic hydrocarbons (PAHs) from bench-scale and small industrial, water-tube boiler are discussed. A Middle Kittanning, and Upper Freeport seam coals were used in the study. Samples were extracted from the reactor outlet and from the inlet and outlet sides of the research boiler's (RB) baghouse using EPA promulgated methods.Only acenaphthene and fluoranthene were detected in down-fired combustor (DFC) samples. In addition to these two, naphthalene was detected in the RB samples. Emission factors ranged from 80 to 320 &mgr;g/kg of fuel fired. Although there were minor trends in the emissions' data, given the reproducibility limits for PAH compounds, no significant differences were found in the emissions with respect to the fuel type or form (pulverized coal (PC) vs. coal-water slurry fuel (CWSF), and raw vs. cleaned coal) and firing conditions (high and low excess air). The PAH emissions showed a decrease with increase in the firing rate.A bench-scale drop-tube reactor (DTR) was used to study the effects of temperature and residence time on PAH formation. The results revealed near constant PAH concentrations in the solid-phase samples, while the PAH concentrations in the vapor-phase samples increased as a function of temperature. At a temperature of around 1300 degrees C, the rate of PAH formation was exceeded by the rate of PAH oxidation, and PAH concentrations in the vapor phase began to decrease.
Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X.C.; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping
2017-01-01
Abstract The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection. To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10. The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples. The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%. The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. PMID:29390519
Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X C; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping
2017-12-01
The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection.To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10.The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples.The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%.The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
[4D-MRI using the synchronized sampling method (SSM)].
Shimada, Yasuhiro; Fujimoto, Ichirou; Takemoto, Hironori; Takano, Sayoko; Masaki, Shinobu; Honda, Kiyoshi; Takeo, Kazuhiro
2002-12-01
A synchronized sampling method (SSM) was developed for the study of voluntary movements by combining the electrocardiographic (ECG) gating method with an external triggering device, and four-dimensional magnetic resonance imaging (4D-MRI) at a rate of 30 frames per second was accomplished by volumetric imaging with the SSM. This method was first applied to the motion imaging of articulatory organs during repetitions of a Japanese five-vowel sequence, and the dynamic change in vocal tract area function was demonstrated with sufficient temporal resolution. This paper describes the methodology, applicability, and limitations of 4D-MRI with the SSM.
Furuta, Etsuko; Ohyama, Ryu-ichiro; Yokota, Shigeaki; Nakajo, Toshiya; Yamada, Yuka; Kawano, Takao; Uda, Tatsuhiko; Watanabe, Yasuo
2014-11-01
The detection efficiencies of tritium samples by using liquid scintillation counter with hydrophilic plastic scintillator (PS) was approximately 48% when the sample of 20 μL was held between 2 PS sheets treated by plasma. The activity and count rates showed a good relationship between 400 Bq to 410 KBq mL(-1). The calculated detection limit of 2 min measurement by the PS was 13 Bq mL(-1) when a confidence was 95%. The plasma method for PS produces no radioactive waste. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mohammadpour, A-H; Nazemian, F; Abtahi, B; Naghibi, M; Gholami, K; Rezaee, S; Nazari, M-R A; Rajabi, O
2008-12-01
Area under the concentration curve (AUC) of mycophenolic acid (MPA) could help to optimize therapeutic drug monitoring during the early post-renal transplant period. The aim of this study was to develop a limited sampling strategy to estimate an abbreviated MPA AUC within the first month after renal transplantation. In this study we selected 19 patients in the early posttransplant period with normal renal graft function (glomerular filtration rate > 70 mL/min). Plasma MPA concentrations were measured using reverse-phase high-performance liquid chromatography. MPA AUC(0-12h) was calculated using the linear trapezoidal rule. Multiple stepwise regression analysis was used to determine the minimal and convenient time points of MPA levels that could be used to derive model equations best fitted to MPA AUC(0-12h). The regression equation for AUC estimation that gave the best performance was AUC = 14.46 C(10) + 15.547 (r(2) = .882). The validation of the method was performed using the jackknife method. Mean prediction error of this model was not different from zero (P > .05) and had a high root mean square prediction error (8.06). In conclusion, this limited sampling strategy provided an effective approach for therapeutic drug monitoring during the early posttransplant period.
Marcellino, W L; Salih, D A; Njahira, M N; Ndiwa, N; Araba, A; El Hussein, A M; Seitzer, U; Ahmed, J S; Bishop, R P; Skilton, R A
2017-08-01
A cross-sectional survey was carried out in four counties of Jonglei State, South Sudan, between May and June 2012 to determine the distribution and northern limit of Theileria parva, the causative agent of East Coast fever in cattle, and its tick vector Rhipicephalus appendiculatus, as a prerequisite to the deployment of relevant control strategies. A total of 1636 ticks, 386 serum samples and 399 blood samples were collected from indigenous, apparently healthy, cattle of different age groups. Tick species were identified morphologically, and the identity of R. appendiculatus was confirmed by DNA barcoding. Overall, the T. parva infection rate in R. appendiculatus was 25% as shown by nested PCR. ELISA was used to assess antibodies to T. parva, and the overall seroprevalence was 22.8%. PCR of the blood samples showed 55 (13.8%) were positive for T. parva. This is the first molecular confirmation of T. parva DNA in areas north of Juba, where it was previously known and established. The northern limit of T. parva was determined as N⁰06.17.792, about 242 Km north from Juba. Implication of this limit on the epidemiology and control of ECF is discussed. © 2016 Blackwell Verlag GmbH.
Two-dimensional simple proportional feedback control of a chaotic reaction system
NASA Astrophysics Data System (ADS)
Mukherjee, Ankur; Searson, Dominic P.; Willis, Mark J.; Scott, Stephen K.
2008-04-01
The simple proportional feedback (SPF) control algorithm may, in principle, be used to attain periodic oscillations in dynamic systems exhibiting low-dimensional chaos. However, if implemented within a discrete control framework with sampling frequency limitations, controller performance may deteriorate. This phenomenon is illustrated using simulations of a chaotic autocatalytic reaction system. A two-dimensional (2D) SPF controller that explicitly takes into account some of the problems caused by limited sampling rates is then derived by introducing suitable modifications to the original SPF method. Using simulations, the performance of the 2D-SPF controller is compared to that of a conventional SPF control law when implemented as a sampled data controller. Two versions of the 2D-SPF controller are described: linear (L2D-SPF) and quadratic (Q2D-SPF). The performance of both the L2D-SPF and Q2D-SPF controllers is shown to be superior to the SPF when controller sampling frequencies are decreased. Furthermore, it is demonstrated that the Q2D-SPF controller provides better fixed point stabilization compared to both the L2D-SPF and the conventional SPF when concentration measurements are corrupted by noise.
NASA Astrophysics Data System (ADS)
Montzka, S. A.
2016-12-01
Measurements from global surface-based air sampling networks provide a fundamental understanding of how and why concentrations of long-lived trace gases are changing over time. Results from these networks are used to quantify trace-gas concentrations and their time-dependent changes on global and smaller scales, and thus provide a means to quantify emission rates, loss frequencies, and mixing processes. Substantial advances in measurement and sampling technologies and the ability of these programs to create and maintain reliable gas standards mean that spatial concentration gradients and time-dependent changes are often very reliably measured. The presence of multiple independent networks allows an assessment of this reliability. Furthermore, recent global `snap-shot' surveys (e.g., HIPPO and ATom) and ongoing atmospheric profiling programs help us assess the ability of surface-based data to describe concentration distributions throughout most of the atmosphere ( 80% of its mass). In this overview talk, I'll explore the usefulness and limitations of existing long-term, ongoing sampling network programs and their advantages and disadvantages for characterizing concentrations on global and regional scales, and how recent advances (and short-term sampling programs) help us assess the accuracy of the surface networks to provide estimates of source and sink magnitudes, and inter-annual variability in both.
[Trace analysis of aristolochic acid A].
Liu, Yalin; Gao, Huimin; Wang, Zhimin; Zhang, Qiwei
2010-12-01
A HPLC method for limit detection of aristolochic acid A in the Chinese herbs containing aristolochic acid or suspected-containing aristolochic acid and their preparations was established. The samples were analyzed on an Alltima C18 column eluted with methanol-water-acetic acid (68:32:1.5) as the mobile phase. Flow rate was at 1.0 mL x min(-1) and the detection wavelength was at 390 nm. The calibration curve was linear over the range from 0.016 to 0.51 g (r = 0.9993) and LOD was 4 ng. The average recovery was 101.2% with RSD of 2.01%. The procedures of sample preparation were systematically investigated. The contents of aristolochic acid A in Radix et Rhizoma Asari bought from market or drugstore were fluctuated from 3.1 to 26.6 microg x g(-1) and 3 of 11 samples accorded with the quality requirement of current Chinese Pharmacopoeia. Among 15 batches samples of Chinese medicaments, only one sample was found to contain aristolochic acid A. The present investigation shows that the method is sensitive and repeatable and it could be used for the limit detection of aristolochic acid A in the Chinese herbal medicines containing trace amount of aristolochic acid A or suspected-containing aristolochic acid A and their preparations.
Are reconstruction filters necessary?
NASA Astrophysics Data System (ADS)
Holst, Gerald C.
2006-05-01
Shannon's sampling theorem (also called the Shannon-Whittaker-Kotel'nikov theorem) was developed for the digitization and reconstruction of sinusoids. Strict adherence is required when frequency preservation is important. Three conditions must be met to satisfy the sampling theorem: (1) The signal must be band-limited, (2) the digitizer must sample the signal at an adequate rate, and (3) a low-pass reconstruction filter must be present. In an imaging system, the signal is band-limited by the optics. For most imaging systems, the signal is not adequately sampled resulting in aliasing. While the aliasing seems excessive mathematically, it does not significantly affect the perceived image. The human visual system detects intensity differences, spatial differences (shapes), and color differences. The eye is less sensitive to frequency effects and therefore sampling artifacts have become quite acceptable. Indeed, we love our television even though it is significantly undersampled. The reconstruction filter, although absolutely essential, is rarely discussed. It converts digital data (which we cannot see) into a viewable analog signal. There are several reconstruction filters: electronic low-pass filters, the display media (monitor, laser printer), and your eye. These are often used in combination to create a perceived continuous image. Each filter modifies the MTF in a unique manner. Therefore image quality and system performance depends upon the reconstruction filter(s) used. The selection depends upon the application.
Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.
Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard
2011-10-10
Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
United States Forest Disturbance Trends Observed Using Landsat Time Series
NASA Technical Reports Server (NTRS)
Masek, Jeffrey G.; Goward, Samuel N.; Kennedy, Robert E.; Cohen, Warren B.; Moisen, Gretchen G.; Schleeweis, Karen; Huang, Chengquan
2013-01-01
Disturbance events strongly affect the composition, structure, and function of forest ecosystems; however, existing U.S. land management inventories were not designed to monitor disturbance. To begin addressing this gap, the North American Forest Dynamics (NAFD) project has examined a geographic sample of 50 Landsat satellite image time series to assess trends in forest disturbance across the conterminous United States for 1985-2005. The geographic sample design used a probability-based scheme to encompass major forest types and maximize geographic dispersion. For each sample location disturbance was identified in the Landsat series using the Vegetation Change Tracker (VCT) algorithm. The NAFD analysis indicates that, on average, 2.77 Mha/yr of forests were disturbed annually, representing 1.09%/yr of US forestland. These satellite-based national disturbance rates estimates tend to be lower than those derived from land management inventories, reflecting both methodological and definitional differences. In particular the VCT approach used with a biennial time step has limited sensitivity to low-intensity disturbances. Unlike prior satellite studies, our biennial forest disturbance rates vary by nearly a factor of two between high and low years. High western US disturbance rates were associated with active fire years and insect activity, while variability in the east is more strongly related to harvest rates in managed forests. We note that generating a geographic sample based on representing forest type and variability may be problematic since the spatial pattern of disturbance does not necessarily correlate with forest type. We also find that the prevalence of diffuse, non-stand clearing disturbance in US forests makes the application of a biennial geographic sample problematic. Future satellite-based studies of disturbance at regional and national scales should focus on wall-to-wall analyses with annual time step for improved accuracy.
Wang, Jiabin; Wu, Fangling; Zhao, Qi
2015-08-01
A C18 monolithic capillary column was utilized as the solid phase microextraction column to construct an in-tube SPME-HPLC system which was used to simultaneously extract and detect five phenoxy acid herbicides, including 2,4-dichlorophenoxyacetic acid (2,4-D), 2- (2-chloro)-phenoxy propionic acid (2,2-CPPA), 2-(3-chloro)-phenoxy propionic acid (2,3- CPPA), phenoxy propionic acid (PPA) and 2-(2,4-dichlorophenoxy) propionic acid (2,4-DP). The operating parameters of the in-tube SPME-HPLC system, including the length of the monolithic column, the sampling flow rate, the sampling time, the elution flow rate and the elution time, had been investigated in detail. The optimized operating parameters of the in-tube SPME-HPLC system were as follow: the length of the monolithic column was 20 cm, the sampling flow rate was 0. 04 mL/min, sampling time was 13 min; the elution flow rate was 0.02 mL/min, elution time was 5 min. Under the optimized conditions, the detection limits of the five phenoxy acid herbicides were as follows: 9 µg/L for PPA, 4 µg/L for 2,2-CPPA, 4 µg/L for 2,3-CPPA, 5 µg/L for 2,4-D, 5 µg/L for 2,4-DP. Compared with the HPLC method with direct injection, the combined system showed a good enrichment factors to the analytes. The recoveries of the five phenoxy acid herbicides were between 79.0% and 98.0% (RSD ≤ 3.9%). This method was successfully used to detect the five phenoxy acid herbicides in water samples with satisfactory results.
Koneff, M.D.; Royle, J. Andrew; Forsell, D.J.; Wortham, J.S.; Boomer, G.S.; Perry, M.C.
2005-01-01
Survey design for wintering scoters (Melanitta sp.) and other sea ducks that occur in offshore waters is challenging because these species have large ranges, are subject to distributional shifts among years and within a season, and can occur in aggregations. Interest in winter sea duck population abundance surveys has grown in recent years. This interest stems from concern over the population status of some sea ducks, limitations of extant breeding waterfowl survey programs in North America and logistical challenges and costs of conducting surveys in northern breeding regions, high winter area philopatry in some species and potential conservation implications, and increasing concern over offshore development and other threats to sea duck wintering habitats. The efficiency and practicality of statistically-rigorous monitoring strategies for mobile, aggregated wintering sea duck populations have not been sufficiently investigated. This study evaluated a 2-phase adaptive stratified strip transect sampling plan to estimate wintering population size of scoters, long-tailed ducks (Clangua hyemalis), and other sea ducks and provide information on distribution. The sampling plan results in an optimal allocation of a fixed sampling effort among offshore strata in the U.S. mid-Atlantic coast region. Phase I transect selection probabilities were based on historic distribution and abundance data, while Phase 2 selection probabilities were based on observations made during Phase 1 flights. Distance sampling methods were used to estimate detection rates. Environmental variables thought to affect detection rates were recorded during the survey and post-stratification and covariate modeling were investigated to reduce the effect of heterogeneity on detection estimation. We assessed cost-precision tradeoffs under a number of fixed-cost sampling scenarios using Monte Carlo simulation. We discuss advantages and limitations of this sampling design for estimating wintering sea duck abundance and mapping distribution and suggest improvements for future surveys.
NASA Technical Reports Server (NTRS)
Liu, Dahai; Goodrich, Ken; Peak, Bob
2006-01-01
This study investigated the effects of synthetic vision system (SVS) concepts and advanced flight controls on single pilot performance (SPP). Specifically, we evaluated the benefits and interactions of two levels of terrain portrayal, guidance symbology, and control-system response type on SPP in the context of lower-landing minima (LLM) approaches. Performance measures consisted of flight technical error (FTE) and pilot perceived workload. In this study, pilot rating, control type, and guidance symbology were not found to significantly affect FTE or workload. It is likely that transfer from prior experience, limited scope of the evaluation task, specific implementation limitations, and limited sample size were major factors in obtaining these results.
Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Bijan
2015-07-01
A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bianchin, Joyce Nunes; Martendal, Edmar; Mior, Renata; Alves, Vanessa Nunes; Araújo, Cleide Sandra Tavares; Coelho, Nívia Maria Melo; Carasek, Eduardo
2009-04-30
In this study a method for the determination of cadmium in fuel alcohol using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry was developed. The sorbent material used was a vermicompost commonly used as a garden fertilizer. The chemical and flow variables of the on-line preconcentration system were optimized by means of a full factorial design. The selected factors were: sorbent mass, sample pH, buffer concentration and sample flow rate. The optimum extraction conditions were obtained using sample pH in the range of 7.3-8.3 buffered with tris(hydroxymethyl)aminomethane at 50 mmol L(-1), a sample flow rate of 4.5 mL min(-1) and 160 mg of sorbent mass. With the optimized conditions, the preconcentration factor, limit of detection and sample throughput were estimated as 32 (for preconcentration of 10 mL sample), 1.7 microg L(-1) and 20 samples per hour, respectively. The analytical curve was linear from 5 up to at least 50 microg L(-1), with a correlation coefficient of 0.998 and a relative standard deviation of 2.4% (35 microg L(-1), n=7). The developed method was successfully applied to spiked fuel alcohol, and accuracy was assessed through recovery tests, with recovery ranging from 94% to 100%.
Shin, Saeam; Kim, Juwon; Kim, Yoonjung; Cho, Sun-Mi; Lee, Kyung-A
2017-10-26
EGFR mutation is an emerging biomarker for treatment selection in non-small-cell lung cancer (NSCLC) patients. However, optimal mutation detection is hindered by complications associated with the biopsy procedure, tumor heterogeneity and limited sensitivity of test methodology. In this study, we evaluated the diagnostic utility of real-time PCR using malignant pleural effusion samples. A total of 77 pleural fluid samples from 77 NSCLC patients were tested using the cobas EGFR mutation test (Roche Molecular Systems). Pleural fluid was centrifuged, and separated cell pellets and supernatants were tested in parallel. Results were compared with Sanger sequencing and/or peptide nucleic acid (PNA)-mediated PCR clamping of matched tumor tissue or pleural fluid samples. All samples showed valid real-time PCR results in one or more DNA samples extracted from cell pellets and supernatants. Compared with other molecular methods, the sensitivity of real-time PCR method was 100%. Concordance rate of real-time PCR and Sanger sequencing plus PNA-mediated PCR clamping was 98.7%. We have confirmed that real-time PCR using pleural fluid had a high concordance rate compared to conventional methods, with no failed samples. Our data demonstrated that the parallel real-time PCR testing using supernatant and cell pellet could offer reliable and robust surrogate strategy when tissue is not available.
Leniency Bias in Performance Ratings: The Big-Five Correlates
Cheng, Kevin H. C.; Hui, C. Harry; Cascio, Wayne F.
2017-01-01
Some researchers assume that employees' personality characteristics affect leniency in rating others and themselves. However, little research has investigated these two tendencies at the same time. In the present study we developed one index for other-rating leniency and another one for self-rating leniency. Based on a review of the literature, we hypothesized that a generous assessment of peers would more likely be made by those who are extroverted and agreeable than by those who are not. Furthermore, a generous assessment of oneself would more likely be made by people who are conscientious and emotionally stable, than by people who are not. We also investigated if the leniency in rating others and the leniency in rating oneself are part of a more general leniency tendency. Data collected from a sample of real estate dealers provided support for the above hypotheses. Limitations and implications for future research are discussed. PMID:28443043
Measurements of Pu and Ra isotopes in soils and sediments by AMS
NASA Astrophysics Data System (ADS)
Tims, S. G.; Hancock, G. J.; Wacker, L.; Fifield, L. K.
2004-08-01
Plutonium fallout from atmospheric nuclear weapons testing in the 1950s and 1960s constitutes an artificial tracer suitable for the study of recent soil erosion and sediment accumulation rates. Long-lived Pu isotopes provide an alternative tracer to the more widely used 137Cs (t1/2=30 a), the concentration of which is decaying at a rate that will limit its long-term application to these studies. For 239,240Pu, the sensitivity of AMS is more than an order of magnitude better than that afforded by α-spectroscopy. Furthermore, AMS can provide a simple, direct measure of the 240Pu/239Pu ratio. Sample profiles from two sites along eastern Australia have been determined with both AMS and α-spectroscopy to provide comparative measurements of the sediment accumulation rate in water bodies and of the soil erosion rate. The two methods are in good agreement. The 228Ra/226Ra ratio potentially provides a probe for tracing the dispersion of uranium mining residues into the neighboring environment. Soil depth profiles of the ratio may provide information on the rate at which mining-derived radioactivity is spread by surface waters, and could be used to assess the effectiveness of remediation and rehabilitation technologies. AMS offers several advantages over the more usual α- and γ-spectroscopy techniques in that it can directly and quickly measure both isotopes in a sample of small size and with simple sample preparation. We show that AMS can be used to measure these isotopes of radium at the sensitivity required for environmental samples using RaC2- as the injected beam species.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Ji; Fischer, Debra A.; Xie, Ji-Wei
2014-03-01
The planet occurrence rate for multiple stars is important in two aspects. First, almost half of stellar systems in the solar neighborhood are multiple systems. Second, the comparison of the planet occurrence rate for multiple stars to that for single stars sheds light on the influence of stellar multiplicity on planet formation and evolution. We developed a method of distinguishing planet occurrence rates for single and multiple stars. From a sample of 138 bright (K{sub P} < 13.5) Kepler multi-planet candidate systems, we compared the stellar multiplicity rate of these planet host stars to that of field stars. Using dynamicalmore » stability analyses and archival Doppler measurements, we find that the stellar multiplicity rate of planet host stars is significantly lower than field stars for semimajor axes less than 20 AU, suggesting that planet formation and evolution are suppressed by the presence of a close-in companion star at these separations. The influence of stellar multiplicity at larger separations is uncertain because of search incompleteness due to a limited Doppler observation time baseline and a lack of high-resolution imaging observation. We calculated the planet confidence for the sample of multi-planet candidates and find that the planet confidences for KOI 82.01, KOI 115.01, KOI 282.01, and KOI 1781.02 are higher than 99.7% and thus validate the planetary nature of these four planet candidates. This sample of bright Kepler multi-planet candidates with refined stellar and orbital parameters, planet confidence estimation, and nearby stellar companion identification offers a well-characterized sample for future theoretical and observational study.« less
NASA Astrophysics Data System (ADS)
Pattanaik, J. K.; Balakrishnan, S.; Bhutani, R.; Singh, P.
2013-11-01
The solute load of the Kaveri River (South India) and its tributaries draining diverse Precambrian terrains during pre-monsoon and monsoon periods was determined. Using average annual flow, total drainage area and atmospheric input corrected major ion concentrations of these rivers chemical weathering rates, annual fluxes of different ionic species to the ocean and CO2 consumption rates were estimated. Bicarbonate is the most dominant ion (27-79% of anion budget) in all the river samples collected during monsoon period followed by Ca2+, whereas, in case of pre-monsoon water samples Na+ is the most dominant ion (in meq/l). Two approaches were adopted to estimate silicate and carbonate weathering rates in the drainage basin. At Musuri silicate weathering rate (SWR) is 9.44 ± 0.29 tons/km2/a and carbonate weathering rate (CWR) is 1.46 ± 0.16 tons/km2/a. More than 90% of the total ionic budget is derived from weathering of silicates in the Kaveri basin. CO2 consumption rate in the basin for silicate weathering FCO2sil is 3.83 ± 0.12 × 105 mol/km2/a (upper limit), which is comparable with the Himalayan rivers at upper reaches. For carbonate weathering (FCO2carb) CO2 consumption rate is 0.15 ± 0.03 × 105 mol/km2/a in the Kaveri basin. The lower limit of CO2 consumption rate corrected for H2SO4 during silicate and carbonate weathering is FCO2sil is 3.24 × 1005 mol/km2/a and FCO2carb 0.13 × 105 mol/km2/a respectively. CO2 sequestered due to silicate weathering in the Kaveri basin is 25.41 (±0.82) × 109 mol/a which represents 0.21 (±0.01)% of global CO2 drawdown. This may be due to tropical climatic condition, high rainfall during both SW and NE monsoon and predominance of silicate rocks in the Kaveri basin.
NASA Astrophysics Data System (ADS)
Middleton, J. L.; Mukhopadhyay, S.; Langmuir, C. H.; Costa, K.; McManus, J. F.; d'Almeida, M.; Huybers, P. J.; Winckler, G.
2016-12-01
Mass accumulation rates of marine sediments are often employed to constrain deposition rates of important proxies such as terrigenous dust, carbonate, and biogenic opal to quantitatively examine variations in continental aridity, atmospheric transport, and biologic productivity across changing climatic conditions. However, deposition rates that are estimated using traditional mass accumulation rates calculated from sediment core age models can be subject to bias from lateral sediment transport and limited age model resolution. Constant flux proxies, such as extraterrestrial helium-3 (3HeET) and excess thorium-230 (230ThXS), can be used to calculate vertical sediment accumulation rates that are independent of age model uncertainties and the effects of lateral sediment transport. While a short half-life limits analyses of 230ThXS to the past 500 ka, 3HeET is stable and could be used to constrain sedimentary fluxes during much of the Cenozoic. Despite the vast paleoceanographic potential of constant flux proxies, few studies have directly compared the behavior of 230ThXS and 3HeET using measurements from the same samples. Sediment grain size fractionation and local scavenging effects may differentially bias one or both proxy systems and complicate the interpretation of 230ThXS or 3HeET data. We will present a new record of vertical sediment accumulation rates spanning the past 600 ka in the Northeast Pacific constrained using analyses of both 3HeET and 230ThXS in two sediment cores from cruise AT26-19 on the Juan de Fuca Ridge. Such a record allows for intercomparison of both constant flux proxies in the mid-ocean ridge environment and examination of sedimentary behavior across multiple glacial cycles. The 230ThXS-derived accumulation rates typically range from 0.5 to 2 g cm-2 ka-1 over the past 450 ka, with periods of maximum deposition coinciding with glacial maxima. Preliminary results of samples analyzed with both 3HeET and 230ThXS indicate relative consistency between vertical sediment accumulation rates computed from each proxy and encourage the use of these constant flux proxies in other sedimentary records.
Kneisel, Stefan; Speck, Michael; Moosmann, Bjoern; Corneillie, Todd M; Butlin, Nathaniel G; Auwärter, Volker
2013-05-01
Serum and urine samples are commonly used for the analysis of synthetic cannabinoids in biofluids; however, their utilization as analytical matrices for drug abstinence control features some substantial drawbacks. While for blood collection invasive sampling is inevitable, the urinary analysis of synthetic cannabinoids is limited by the lack of available reference standards of the respective major metabolites. Moreover, the long detectability of synthetic cannabinoids in both matrices hampers the identification of a recent synthetic cannabinoid use. This article describes the development, validation and application of an LC/ESI-MS/MS method for the quantification of 28 synthetic cannabinoids in neat oral fluid (OF) samples. OF samples were prepared by protein precipitation using ice-cold acetonitrile. Chromatographic separation was achieved by gradient elution on a Luna Phenyl Hexyl column (50 × 2 mm, 5 μm), while detection was carried out on a QTrap 4000 instrument in positive ionization mode. The limits of detection ranged from 0.02 to 0.40 ng/mL, whereas the lower limits of quantification ranged from 0.2 to 4.0 ng/mL. The method was applied to authentic samples collected during two preliminary studies in order to obtain insights into the general detectability and detection windows of synthetic cannabinoids in this matrix. The results indicate that synthetic cannabinoids are transferred from the blood stream into OF and vice versa only at a very low rate. Therefore, positive OF samples are due to contamination of the oral cavity during smoking. As these drug-contaminations could be detected up to approximately 2 days, neat oral fluid appears to be well suited for detection of a recent synthetic cannabinoid use.
Weightman, R M; Huckle, A J; Roques, S E; Ginsburg, D; Dyer, C J
2012-01-01
Wild rocket (Diplotaxis tenuifolia) is a leafy vegetable known for its high tissue nitrate concentration (TNC) which can exceed the limits set in the relevant European legislation designed to protect human health. The aim of this work was to understand the factors influencing TNC and to develop best practice guidelines to growers. Commercial crops of field-grown wild rocket were studied over two seasons. In 2010, ten separate crops were sampled representing a range of soil types and time periods during the summer. Two fields sampled using a 'W'- or 'X'-shaped sampling pattern demonstrated that 10 incremental samples bulked to make 1 kg of fresh material could be used to provide an adequate sample for determination of TNC in the wild rocket crop, as is the case for other leafy vegetables. Of eight commercial crops sampled in 2010 with an average nitrogen (N) fertiliser application of 104 kg N ha(-1), two exceeded the limit of 6000 mg NO3(-) kg(-1) set in the legislation. In 2011, six N response experiments were carried out, and only two sites showed a significant yield response to N fertiliser. The reason for the lack of response at the other sites was principally due to high levels of soil mineral N prior to drilling, meaning the crops' requirement for N was satisfied without additional fertiliser N. In the experimental situation at an N fertiliser application rate of 120 kg N ha(-1), 50% of crops would have exceeded the 6000 mg NO3(-) kg(-1) limit. In both seasons, low radiation levels in the 5 days prior to harvest were shown to increase TNC, although the relationship was also influenced by N supply. Strategies for optimising N nutrition of field-grown wild rocket are discussed.
USDA-ARS?s Scientific Manuscript database
Data on physiological parameters of A, gs, Em, Ci, and IWUE in grain sorghum (Sorghum bicolor L. Moench) is limited. Flag leaves from three plants of two hybrids, grown using added N fertilizer rates of 0.0, 112, and 224 kg ha-1 near Elizabeth, MS were field sampled for these parameters at growth s...
ERIC Educational Resources Information Center
Ting, Laura
2011-01-01
Limited research exists on social work students' level of depression and help-seeking beliefs. This study empirically examined the rates of depression among 215 BSW students and explored students' reasons for not using mental health services. Approximately 50% scored at or above the Center for Epidemiologic Studies Depression Scale cutoff;…
Autism spectrum disorder and pet therapy.
Siewertsen, Caitlin M; French, Emma D; Teramoto, Masaru
2015-01-01
Autism Spectrum Disorder (ASD) encompasses a wide range of social and mental afflictions that are difficult to treat. Due to a lack of established treatments for ASD, alternative therapies have been the primary form of intervention. One of these alternatives is pet therapy, a field that has experienced growing interest and has recently accumulated studies that investigate its efficacy. This article reviews and summarizes that effectiveness as well as the findings and limitations associated with pet therapy for ASD. The majority of research on ASD and pet therapy has examined children and has primarily used dogs and horses for therapy. Studies have shown positive effects for the therapy, including high satisfaction rates among the participants' families. Major limitations of studies in the current literature include the lack of control groups and small sample sizes. Future research should incorporate better study designs and large samples to validate pet therapy as an appropriate treatment for ASD.
Sexual orientation and treatment-seeking for depression in a multilingual worldwide sample
Rutter, Tara M.; Flentje, Annesa; Dilley, James W.; Barakat, Suzanne; Liu, Nancy H.; Gross, Margaret S.; Muñoz, Ricardo F.; Leykin, Yan
2016-01-01
Background Prior research has found higher rates of mental health problems among sexual minority individuals. We examine treatment-seeking for depression, as well as its relationship with sexual orientation, in a large, multilingual, international sample. Method Participants in an automated, quintilingual internet-based depression screening tool were screened for depression, and completed several background measures, including sexual orientation (with an option to decline to state) and past and current depression treatment seeking. Results 3,695 participants screened positive for current or past depression and responded to the sexual orientation question. Those who declined to state their sexual orientation were far less likely to seek any treatment than individuals endorsing any orientation; they were especially unlikely to seek psychotherapy. Individuals identifying as bisexual sought both psychotherapy and alternative treatments at a higher rate than other groups. An interaction was observed between sexual orientation and gender, such that lesbian women were especially likely to have used psychotherapy. Other variables that emerged as significant predictors of treatment-seeking for depression included age and participant's language. Limitations Limitations include possible misinterpretation of translated terms due to regional differences, and possible limits to generalizability due to this study being conducted on the internet. Conclusions Our results suggest that individuals who decline to state their sexual orientation may be more likely to forgo effective treatments for depression. Further studies of depression service utilization should focus on developing treatment modalities that could better engage sexual minority individuals, especially those who are reluctant to disclose their orientation. PMID:27466746
The Porosity of the neutral ISM in 20 THINGS Galaxies
NASA Astrophysics Data System (ADS)
Bagetakos, I.; Brinks, E.; Walter, F.; de Blok, W. J. G.; Usero, A.; Leroy, A. K.; Rich, J. W.; Kennicutt, R. C.
2011-11-01
We present an analysis of the properties of H i holes detected in 20 galaxies that are part of "The H i Nearby Galaxy Survey". We detected more than 1000 holes in total in the sampled galaxies. The holes are found throughout the disks of the galaxies, out to the edge of the H i disk. We find that shear limits the age of holes in spirals. Shear is less important in dwarf galaxies which explains why H i holes in dwarfs are rounder, on average than in spirals. Shear is particularly strong in the inner part of spiral galaxies, limiting the lifespan of holes there and explaining why we find that holes outside R25 are larger and older. We proceed to derive the surface and volume porosity and find that this correlates with the type of the host galaxy: later Hubble types tend to be more porous. The size distribution of the holes in our sample follows a power law with a slope of aν ~ -2.9. Assuming that the holes are the result of massive star formation, we derive values for the supernova rate (SNR) and star formation rate (SFR) which scales with the SFR derived based on other tracers. If we extrapolate the observed number of holes to include those that fall below our resolution limit, down to holes created by a single supernova, we find that our results are compatible with the hypothesis that H i holes result from star formation.
Alves, Vanessa N; Borges, Simone S O; Coelho, Nivia M M
2011-01-01
This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extraction conditions were obtained using a sample pH of 4.0, a sample flow rate of 6.0 mL min(-1), 30.0 mg of sorbent mass, and 1.0 mol L(-1) HNO(3) as the eluent at a flow rate of 4.0 mL min(-1). The limit of detection for zinc was 1.9 μg L(-1), and the precision was below 0.82% (20.0 μg L(-1), n = 7). The analytical curve was linear from 2 to 50 μg L(-1), with a correlation coefficient of 0.9996. The method developed was successfully applied to spiked Brazilian sugar cane spirit, and accuracy was assessed through recovery tests, with results ranging from 83% to 100%.
Alves, Vanessa N.; Borges, Simone S. O.; Coelho, Nivia M. M.
2011-01-01
This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extraction conditions were obtained using a sample pH of 4.0, a sample flow rate of 6.0 mL min−1, 30.0 mg of sorbent mass, and 1.0 mol L−1 HNO3 as the eluent at a flow rate of 4.0 mL min−1. The limit of detection for zinc was 1.9 μg L−1, and the precision was below 0.82% (20.0 μg L−1, n = 7). The analytical curve was linear from 2 to 50 μg L−1, with a correlation coefficient of 0.9996. The method developed was successfully applied to spiked Brazilian sugar cane spirit, and accuracy was assessed through recovery tests, with results ranging from 83% to 100%. PMID:21785595
Face recognition based on symmetrical virtual image and original training image
NASA Astrophysics Data System (ADS)
Ke, Jingcheng; Peng, Yali; Liu, Shigang; Li, Jun; Pei, Zhao
2018-02-01
In face representation-based classification methods, we are able to obtain high recognition rate if a face has enough available training samples. However, in practical applications, we only have limited training samples to use. In order to obtain enough training samples, many methods simultaneously use the original training samples and corresponding virtual samples to strengthen the ability of representing the test sample. One is directly using the original training samples and corresponding mirror samples to recognize the test sample. However, when the test sample is nearly symmetrical while the original training samples are not, the integration of the original training and mirror samples might not well represent the test samples. To tackle the above-mentioned problem, in this paper, we propose a novel method to obtain a kind of virtual samples which are generated by averaging the original training samples and corresponding mirror samples. Then, the original training samples and the virtual samples are integrated to recognize the test sample. Experimental results on five face databases show that the proposed method is able to partly overcome the challenges of the various poses, facial expressions and illuminations of original face image.
[Evaluation of the level of endemic tuberculosis in a survey of Banqui (Central African Republic)].
Sarda, J; Monges, J; Pujol, C; Ndoyo, J; Samba, M; Monges, P; Merouze, J; Testa, J
1993-01-01
A cluster sample survey on tuberculosis has been carried out in Bangui in February 1988. The bimodal distribution of the diameters of IDR on children aged between 5 to 9, gives evidence of a circulation of some non typical mycobacteriae and enables to fix the limit of positivity at 14 mm. The prevalence rate of the tuberculotic infection is 7.9 +/- 1.7% in the surveyed children population at school. The annual risk of infection is evaluated at 1.09% that ranks the Centrafrican Republic in the countries with a low prevalence rate.
Methods for threshold determination in multiplexed assays
Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J
2014-06-24
Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.
Age-related changes in the auditory brainstem response.
Konrad-Martin, Dawn; Dille, Marilyn F; McMillan, Garnett; Griest, Susan; McDermott, Daniel; Fausti, Stephen A; Austin, Donald F
2012-01-01
This cross-sectional study had two goals: (1) Identify and quantify the effects of aging on the auditory brainstem response (ABR); (2) Describe how click rate and hearing impairment modify effects of aging. RESEARCH DESIGN AND ANALYSIS: ABR measures were obtained from 131 predominately male Veteran participants aged 26 to 71 yr. Metrics analyzed include amplitude and latency for waves I, III, and V, and the I-V interpeak latency interval (IPI) at three repetition rates (11, 51, and 71 clicks/sec) using both polarities. In order to avoid confounding from missing data due to hearing impairment, participants had hearing thresholds <40 dB HL at 2 kHz and 70 dB HL at 4 kHz in at least one ear. Additionally, the median 2, 3, and 4 kHz pure tone threshold average (PTA2,3,4) for the sample, ∼17 dB HL, was used to delineate subgroups of better and worse hearing ears, and only the better hearing sample was modeled statistically. We modeled ABR responses using age, repetition rate, and PTA2,3,4 as covariates. Random effects were used to model correlation between the two ears of a subject and across repetition rates. Inferences regarding effects of aging on ABR measures at each rate were derived from the fitted model. Results were compared to data from subjects with poorer hearing. Aging substantially diminished amplitudes of all of the principal ABR peaks, largely independent of any threshold differences within the group. For waves I and III, age-related amplitude decrements were greatest at a low (11/sec) click rate. At the 11/sec rate, the model-based mean wave III amplitude was significantly smaller in older compared with younger subjects even after adjusting for wave I amplitude. Aging also increased ABR peak latencies, with significant shifts limited to early waves. The I-V IPI did not change with age. For both younger and older subjects, increasing click presentation rate significantly decreased amplitudes of early peaks and prolonged latencies of later peaks, resulting in increased IPIs. Advanced age did not enhance effects of rate. Instead, the rate effect on wave I and III amplitudes was attenuated for the older subjects due to reduced peak amplitudes at lower click rates. Compared with model predictions from the sample of better hearing subjects, mean ABR amplitudes were diminished in the group with poorer hearing, and wave V latencies were prolonged. In a sample of veterans, aging substantially reduced amplitudes of all principal ABR peaks, with significant latency shifts limited to waves I and III. Aging did not influence the I-V IPI even at high click rates, suggesting that the observed absolute latency changes associated with aging can be attributed to changes in auditory nerve input. In contrast, ABR amplitude changes with age are not adequately explained by changes in wave I. Results suggest that aging reduces the numbers and/or synchrony of contributing auditory nerve units. Results also support the concept that aging reduces the numbers, though perhaps not the synchrony, of central ABR generators. American Academy of Audiology.
Cremonini, F; Houghton, L A; Camilleri, M; Ferber, I; Fell, C; Cox, V; Castillo, E J; Alpers, D H; Dewit, O E; Gray, E; Lea, R; Zinsmeister, A R; Whorwell, P J
2005-12-01
We assessed reproducibility of measurements of rectal compliance and sensation in health in studies conducted at two centres. We estimated samples size necessary to show clinically meaningful changes in future studies. We performed rectal barostat tests three times (day 1, day 1 after 4 h and 14-17 days later) in 34 healthy participants. We measured compliance and pressure thresholds for first sensation, urgency, discomfort and pain using ascending method of limits and symptom ratings for gas, urgency, discomfort and pain during four phasic distensions (12, 24, 36 and 48 mmHg) in random order. Results obtained at the two centres differed minimally. Reproducibility of sensory end points varies with type of sensation, pressure level and method of distension. Pressure threshold for pain and sensory ratings for non-painful sensations at 36 and 48 mmHg distension were most reproducible in the two centres. Sample size calculations suggested that crossover design is preferable in therapeutic trials: for each dose of medication tested, a sample of 21 should be sufficient to demonstrate 30% changes in all sensory thresholds and almost all sensory ratings. We conclude that reproducibility varies with sensation type, pressure level and distension method, but in a two-centre study, differences in observed results of sensation are minimal and pressure threshold for pain and sensory ratings at 36-48 mmHg of distension are reproducible.
Permeability and compressibility of resedimented Gulf of Mexico mudrock
NASA Astrophysics Data System (ADS)
Betts, W. S.; Flemings, P. B.; Schneider, J.
2011-12-01
We use a constant-rate-of strain consolidation test on resedimented Gulf of Mexico mudrock to determine the compression index (Cc) to be 0.618 and the expansion index (Ce) to be 0.083. We used crushed, homogenized Pliocene and Pleistocene mudrock extracted from cored wells in the Eugene Island block 330 oil field. This powdered material has a liquid limit (LL) of 87, a plastic limit (PL) of 24, and a plasticity index (PI) of 63. The particle size distribution from hydrometer analyses is approximately 65% clay-sized particles (<2 μm) with the remainder being less than 70 microns in diameter. Resedimented specimens have been used to characterize the geotechnical and geophysical behavior of soils and mudstones independent of the variability of natural samples and without the effects of sampling disturbance. Previous investigations of resedimented offshore Gulf of Mexico sediments (e.g. Mazzei, 2008) have been limited in scope. This is the first test of the homogenized Eugene Island core material. These results will be compared to in situ measurements to determine the controls on consolidation over large stress ranges.
Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan
2017-01-01
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806
Aaltonen, T.; Álvarez González, B.; Amerio, S.; ...
2012-05-23
We present the results of a search for dark matter production in the monojet signature. We analyze a sample of Tevatron pp̄ collisions at √s=1.96 TeV corresponding to an integrated luminosity of 6.7 fb⁻¹ recorded by the CDF II detector. In events with large missing transverse energy and one energetic jet, we find good agreement between the standard model prediction and the observed data. We set 90% confidence level upper limits on the dark matter production rate. The limits are translated into bounds on nucleon-dark matter scattering rates which are competitive with current direct detection bounds on spin-independent interaction belowmore » a dark matter candidate mass of 5 GeV/c², and on spin-dependent interactions up to masses of 200 GeV/c².« less
Aaltonen, T; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Bai, Y; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Forrest, R; Fox, P J; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harnik, R; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lecompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Varganov, A; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wagner, R L; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Wick, F; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhou, C; Zucchelli, S
2012-05-25
We present the results of a search for dark matter production in the monojet signature. We analyze a sample of Tevatron pp[over ¯] collisions at √s=1.96 TeV corresponding to an integrated luminosity of 6.7 fb(-1) recorded by the CDF II detector. In events with large missing transverse energy and one energetic jet, we find good agreement between the standard model prediction and the observed data. We set 90% confidence level upper limits on the dark matter production rate. The limits are translated into bounds on nucleon-dark matter scattering rates which are competitive with current direct detection bounds on spin-independent interaction below a dark matter candidate mass of 5 GeV/c(2), and on spin-dependent interactions up to masses of 200 GeV/c(2).
Sandner, F; Dott, W; Hollender, J
2001-03-01
The toxic potential of formaldehyde and other aliphatic/aromatic carbonyl compounds requires the determination of even low amounts of these compounds in indoor air. The existing DFG-method for workplace monitoring using adsorption at 2,4-dinitrophenylhydrazine (DNPH)-coated sorbents followed by HPLC-UV/DAD analysis of the extract was modified in order to decrease detection limits. The improvement included an increase in volume and rate of the air sampling, testing applicability of different adsorption materials and a decrease of the extraction volume of the hydrazones. 13 DNPH-derivatives could be separated well on a RP18-column followed by UV/DAD-detection at 365 nm. Recovery rates of 70-100% were determined (apart from acetone with 19%) using dynamically produced artifical carbonyl atmospheres. Detection limits of 0.05-0.4 microgram/m3 were reached by this method which are sufficient for indoor air monitoring.
Single pulse two photon fluorescence lifetime imaging (SP-FLIM) with MHz pixel rate.
Eibl, Matthias; Karpf, Sebastian; Weng, Daniel; Hakert, Hubertus; Pfeiffer, Tom; Kolb, Jan Philip; Huber, Robert
2017-07-01
Two-photon-excited fluorescence lifetime imaging microscopy (FLIM) is a chemically specific 3-D sensing modality providing valuable information about the microstructure, composition and function of a sample. However, a more widespread application of this technique is hindered by the need for a sophisticated ultra-short pulse laser source and by speed limitations of current FLIM detection systems. To overcome these limitations, we combined a robust sub-nanosecond fiber laser as the excitation source with high analog bandwidth detection. Due to the long pulse length in our configuration, more fluorescence photons are generated per pulse, which allows us to derive the lifetime with a single excitation pulse only. In this paper, we show high quality FLIM images acquired at a pixel rate of 1 MHz. This approach is a promising candidate for an easy-to-use and benchtop FLIM system to make this technique available to a wider research community.
Rising rates of labor induction: present concerns and future strategies.
Rayburn, William F; Zhang, Jun
2002-07-01
The rate of labor induction nationwide increased gradually from 9.5% to 19.4% between 1990 and 1998. Reasons for this doubling of inductions relate to widespread availability of cervical ripening agents, pressure from patients, conveniences to physicians, and litigious constraints. The increase in medically indicated inductions was slower than the overall increase, suggesting that induction for marginal or elective reasons has risen more rapidly. Data to support or refute the benefits of marginal or elective inductions are limited. Many trials of inductions for marginal indications are either nonexistent or retrospective with small sample sizes, thereby limiting definitive conclusions. Until prospective clinical trials can better validate reasons for the liberal use of labor induction, it would seem prudent to maintain a cautious approach, especially among nulliparous women. Strategies are proposed for developing evidence-based guidelines to reduce the presumed increase in health care costs, risk of cesarean delivery for nulliparas, and overscheduling in labor and delivery.
Cvetković, V.; Niedermann, S.; Pejović, V.; Amthauer, G.; Boev, B.; Bosch, F.; Aničin, I.; Henning, W. F.
2016-01-01
Abstract This paper focuses on constraining the erosion rate in the area of the Allchar Sb‐As‐Tl‐Au deposit (Macedonia). It contains the largest known reserves of lorandite (TlAsS2), which is essential for the LORanditeEXperiment (LOREX), aimed at determining the long‐term solar neutrino flux. Because the erosion history of the Allchar area is crucial for the success of LOREX, we applied terrestrial in situ cosmogenic nuclides including both radioactive (26Al and 36Cl) and stable (3He and 21Ne) nuclides in quartz, dolomite/calcite, sanidine, and diopside. The obtained results suggest that there is accordance in the values obtained by applying 26Al, 36Cl, and 21Ne for around 85% of the entire sample collection, with resulting erosion rates varying from several tens of m/Ma to ∼165 m/Ma. The samples from four locations (L‐8 CD, L1b/R, L1c/R, and L‐4/ADR) give erosion rates between 300 and 400 m/Ma. Although these localities reveal remarkably higher values, which may be explained by burial events that occurred in part of Allchar, the erosion rate estimates mostly in the range between 50 and 100 m/Ma. This range further enables us to estimate the vertical erosion rate values for the two main ore bodies Crven Dol and Centralni Deo. We also estimate that the lower and upper limits of average paleo‐depths for the ore body Centralni Deo from 4.3 Ma to the present are 250–290 and 750–790 m, respectively, whereas the upper limit of paleo‐depth for the ore body Crven Dol over the same geological age is 860 m. The estimated paleo‐depth values allow estimating the relative contributions of 205Pb derived from pp‐neutrino and fast cosmic‐ray muons, respectively, which is an important prerequisite for the LOREX experiment. PMID:27587984
Soil strength and macropore volume limit root elongation rates in many UK agricultural soils.
Valentine, Tracy A; Hallett, Paul D; Binnie, Kirsty; Young, Mark W; Squire, Geoffrey R; Hawes, Cathy; Bengough, A Glyn
2012-07-01
Simple indicators of crop and cultivar performance across a range of soil types and management are needed for designing and testing sustainable cropping practices. This paper determined the extent to which soil chemical and physical properties, particularly soil strength and pore-size distribution influences root elongation in a wide range of agricultural top soils, using a seedling-based indicator. Intact soil cores were sampled from the topsoil of 59 agricultural fields in Scotland, representing a wide geographic spread, range of textures and management practices. Water release characteristics, dry bulk density and needle penetrometer resistance were measured on three cores from each field. Soil samples from the same locations were sieved, analysed for chemical characteristics, and packed to dry bulk density of 1.0 g cm(-3) to minimize physical constraints. Root elongation rates were determined for barley seedlings planted in both intact field and packed soil cores at a water content close to field capacity (-20 kPa matric potential). Root elongation in field soil was typically less than half of that in packed soils. Penetrometer resistance was typically between 1 and 3 MPa for field soils, indicating the soils were relatively hard, despite their moderately wet condition (compared with <0.2 MPa for packed soil). Root elongation was strongly linked to differences in physical rather than chemical properties. In field soil root elongation was related most closely to the volume of soil pores between 60 µm and 300 µm equivalent diameter, as estimated from water-release characteristics, accounting for 65.7 % of the variation in the elongation rates. Root elongation rate in the majority of field soils was slower than half of the unimpeded (packed) rate. Such major reductions in root elongation rates will decrease rooting volumes and limit crop growth in soils where nutrients and water are scarce.
Direct Measurement of the Supernova Rate in Starburst Galaxies
NASA Technical Reports Server (NTRS)
Bregman, Jesse D.; Temi, Pasquale; Rank, David; DeVincenzi, Donald L. (Technical Monitor)
1999-01-01
Supernovae play a key role in the dynamics, structure, and chemical evolution of galaxies. The massive stars that end their lives as supernovae live for short times. Many are still associated with dusty star formation regions when they explode, making them difficult to observe at visible wavelengths. In active star forming regions (galactic nuclei and starburst regions), dust extintion is especially severe. Thus, determining the supernova rate in the active star forming regions of galaxies, where the supernova rate can be one or two orders of magnitude higher than the average, has proven to be difficult. From observations of SN1987A, we know that the [NiII] 6.63 micron emission line was the strongest line in the infrared spectrum for a period of a year and a half after the explosion. Since dust extintion is much less at 6.63 pm than at visible wavelengths (A(sub 6.63)/A(sub V) = 0.025), the NiII line can be used as a sensitive probe for the detection of recent supernovae. We have observed a sample of starburst galaxies at 6.63 micron using ISOCAM to search for the NiII emission line characteristic of recent supernovae. We did not detect any NiII line emission brighter than a 5sigma limit of 5 mJy. We can set upper limits to the supernova rate in our sample, scaled to the rate in M82, of less than 0.3 per year at the 90% confidence level using Bayesian methods. Assuming that a supernova would have a NiII with the same luminosity as observed in SN1987A, we find less than 0.09 and 0.15 per year at the 50% and 67% confidence levels. These rates are somewhat less if a more normal type II supernovae has a NiII line luminosity greater than the line in SN1987A.
Sahmetlioglu, Ertugrul; Yilmaz, Erkan; Aktas, Ece; Soylak, Mustafa
2014-02-01
A multi-walled carbon nanotubes-polypyrrole conducting polymer nanocomposite has been synthesized, characterized and used for the separation and preconcentration of lead at trace levels in water samples prior to its flame atomic absorption spectrometric detection. The analytical parameters like pH, sample volume, eluent, sample flow rate that were affected the retentions of lead(II) on the new nanocomposite were optimized. Matrix effects were also investigated. Limit of detection and preconcentration factors were 1.1 µg L(-1) and 200, respectively. The adsorption capacity of the nanocomposite was 25.0mg lead(II) per gram composite. The validation of the method was checked by using SPS-WW2 Waste water Level 2 certified reference material. The method was applied to the determination of lead in water samples with satisfactory results. © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kane, Steven Ze
A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo containers uniformly filled with wood (low-Z) or iron (high-Z) at densities ranging from 0.1 g/cm3 to 0.4 g/cm3, the maximal density for a uniformly fully loaded 40-ft standard cargo container. In addition, samples were located at the center of a given container to study worst-case scenarios. The RAPID technique allows for the interrogation of containers at neutron production rates between 1x108 neutrons/s and 4x108 neutrons/s, depending on cargo material and density. These rates are low enough to prevent transmutation of materials in cargo and radiation safety hazards are limited. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10-4 false positive rate per interrogated voxel of cargo. The detection of 5-kg of U-235 was chosen because this quantity of material is near the lower limit of the amount of special nuclear material that might be used in a nuclear weapon. This is in contrast to the 25-kg suggested sensitivity proposed by the International Atomic Energy Agency (IAEA).
Hyun, Jung-Ho
2006-08-01
Shipboard enrichment incubation experiments were performed to elucidate the limiting resources for heterotrophic prokaryotic production and to discuss the potential impact of bottom water and sediment discharges in relation to manganese (Mn) nodule exploitation on the heterotrophic prokaryotes in the oligotrophic northeast equatorial Pacific. Compared to an unamended control, the production of heterotrophic prokaryotes increased 25-fold in water samples supplemented with amino acids (i.e., organic carbon plus nitrogen), whereas the production increased five and two times, respectively, in samples supplemented with either glucose or ammonium alone. These results indicate that heterotrophic prokaryote production in the northeast equatorial Pacific was co-limited by the availability of dissolved organic carbon and inorganic nitrogen. In samples from the nutrient-depleted surface mixed layer (10-m depth), the addition of a slurry of bottom water and sediment doubled heterotrophic prokaryote production compared to an unamended control, whereas sonicating the slurry prior to addition quadrupled the production rate. However, little difference was observed between an unamended control and slurry-amended samples in the subsurface chlorophyll a (Chl a) maximum (SCM) layer. Thus, the impact of slurry discharge is more significant at the nutrient-depleted surface mixed layer than at the high-nutrient SCM layer. The greatly enhanced prokaryote production resulting from the addition of sonicated slurry further suggests that dissociated organic carbon may directly stimulate heterotrophic prokaryote production in the surface mixed layer. Overall, the results suggest that the surface discharge of bottom water and sediments during manganese nodule exploitation could have a significant environmental impact on the production of heterotrophic prokaryotes that are currently resource limited.
Classification of weld defect based on information fusion technology for radiographic testing system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Hongquan; Liang, Zeming, E-mail: heavenlzm@126.com; Gao, Jianmin
Improving the efficiency and accuracy of weld defect classification is an important technical problem in developing the radiographic testing system. This paper proposes a novel weld defect classification method based on information fusion technology, Dempster–Shafer evidence theory. First, to characterize weld defects and improve the accuracy of their classification, 11 weld defect features were defined based on the sub-pixel level edges of radiographic images, four of which are presented for the first time in this paper. Second, we applied information fusion technology to combine different features for weld defect classification, including a mass function defined based on the weld defectmore » feature information and the quartile-method-based calculation of standard weld defect class which is to solve a sample problem involving a limited number of training samples. A steam turbine weld defect classification case study is also presented herein to illustrate our technique. The results show that the proposed method can increase the correct classification rate with limited training samples and address the uncertainties associated with weld defect classification.« less
Jiang, Hongquan; Liang, Zeming; Gao, Jianmin; Dang, Changying
2016-03-01
Improving the efficiency and accuracy of weld defect classification is an important technical problem in developing the radiographic testing system. This paper proposes a novel weld defect classification method based on information fusion technology, Dempster-Shafer evidence theory. First, to characterize weld defects and improve the accuracy of their classification, 11 weld defect features were defined based on the sub-pixel level edges of radiographic images, four of which are presented for the first time in this paper. Second, we applied information fusion technology to combine different features for weld defect classification, including a mass function defined based on the weld defect feature information and the quartile-method-based calculation of standard weld defect class which is to solve a sample problem involving a limited number of training samples. A steam turbine weld defect classification case study is also presented herein to illustrate our technique. The results show that the proposed method can increase the correct classification rate with limited training samples and address the uncertainties associated with weld defect classification.
Doll, J.; Dupuis, P.; Nyquist, P.
2017-02-08
Parallel tempering, or replica exchange, is a popular method for simulating complex systems. The idea is to run parallel simulations at different temperatures, and at a given swap rate exchange configurations between the parallel simulations. From the perspective of large deviations it is optimal to let the swap rate tend to infinity and it is possible to construct a corresponding simulation scheme, known as infinite swapping. In this paper we propose a novel use of large deviations for empirical measures for a more detailed analysis of the infinite swapping limit in the setting of continuous time jump Markov processes. Usingmore » the large deviations rate function and associated stochastic control problems we consider a diagnostic based on temperature assignments, which can be easily computed during a simulation. We show that the convergence of this diagnostic to its a priori known limit is a necessary condition for the convergence of infinite swapping. The rate function is also used to investigate the impact of asymmetries in the underlying potential landscape, and where in the state space poor sampling is most likely to occur.« less
Boulyga, Sergei F; Tibi, Markus; Heumann, Klaus G
2004-01-01
The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.
Experimental study on anomalous neutron production in deuterium/solid system
NASA Astrophysics Data System (ADS)
He, Jianyu; Zhu, Rongbao; Wang, Xiaozhong; Lu, Feng; Luo, Longjun; Liu, Hengjun; Jiang, Jincai; Tian, Baosheng; Chen, Guoan; Yuan, Yuan; Dong, Baiting; Yang, Liucheng; Qiao, Shengzhong; Yi, Guoan; Guo, Hua; Ding, Dazhao; Menlove, H. O.
1991-05-01
A series of experiments on both D2O electrolysis and thermal cycle of deuterium absorbed Ti Turnings has been designed to examine the anomalous phenomena in Deuterium/Solid System. A neutron detector containing 16 BF3 tubes with a detection limit of 0.38 n/s for two hour counting was used for electrolysis experiments. No neutron counting rate statistically higher than detection limit was observed from Fleischmann & Pons type experiments. An HLNCC neutron detector equipped with 18 3He tubes and a JSR-11 shift register unit with a detection limit of 0.20 n/s for a two hour run was employed to study the neutron signals in D2 gas experiments. Different material pretreatments were selected to review the changes in frequency and size of the neutron burst production. Experiment sequence was deliberately designed to distinguish the neutron burst from fake signals, e.g. electronic noise pickup, the cosmic rays and other sources of environmental background. Ten batches of dry fusion samples were tested, among them, seven batches with neutron burst signals occurred roughly at the temperature from -100 degree centigrade to near room temperature. In the first four runs of a typical sample batch, seven neutron bursts were observed with neutron numbers from 15 to 482, which are 3 and 75 times, respectively, higher than the uncertainty of background. However, no bursts happened for H2 dummy samples running in-between and afterwards and for sample batch after certain runs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, E.; Zauderer, B. A.; Chary, R.-R.
2014-12-01
We present rest-frame far-infrared (FIR) and optical observations of the host galaxy of GRB 090423 at z = 8.23 from the Atacama Large Millimeter Array (ALMA) and the Spitzer Space Telescope, respectively. The host remains undetected to 3σ limits of F {sub ν}(222 GHz) ≲ 33 μJy and F {sub ν}(3.6 μm) ≲ 81 nJy. The FIR limit is about 20 times fainter than the luminosity of the local ULIRG Arp 220 and comparable to the local starburst M 82. Comparing this with model spectral energy distributions, we place a limit on the infrared (IR) luminosity of L {sub IR}(8-1000more » μm) ≲ 3 × 10{sup 10} L {sub ☉}, corresponding to a limit on the obscured star formation rate of SFR{sub IR}≲5 M {sub ☉} yr{sup –1}. For comparison, the limit on the unobscured star formation rate from Hubble Space Telescope rest-frame ultraviolet (UV) observations is SFR{sub UV} ≲ 1 M {sub ☉} yr{sup –1}. We also place a limit on the host galaxy stellar mass of M {sub *} ≲ 5 × 10{sup 7} M {sub ☉} (for a stellar population age of 100 Myr and constant star formation rate). Finally, we compare our millimeter observations to those of field galaxies at z ≳ 4 (Lyman break galaxies, Lyα emitters, and submillimeter galaxies) and find that our limit on the FIR luminosity is the most constraining to date, although the field galaxies have much larger rest-frame UV/optical luminosities than the host of GRB 090423 by virtue of their selection techniques. We conclude that GRB host galaxies at z ≳ 4, especially those with measured interstellar medium metallicities from afterglow spectroscopy, are an attractive sample for future ALMA studies of high redshift obscured star formation.« less
Physiologically Relevant Changes in Serotonin Resolved by Fast Microdialysis
2013-01-01
Online microdialysis is a sampling and detection method that enables continuous interrogation of extracellular molecules in freely moving subjects under behaviorally relevant conditions. A majority of recent publications using brain microdialysis in rodents report sample collection times of 20–30 min. These long sampling times are due, in part, to limitations in the detection sensitivity of high performance liquid chromatography (HPLC). By optimizing separation and detection conditions, we decreased the retention time of serotonin to 2.5 min and the detection threshold to 0.8 fmol. Sampling times were consequently reduced from 20 to 3 min per sample for online detection of serotonin (and dopamine) in brain dialysates using a commercial HPLC system. We developed a strategy to collect and to analyze dialysate samples continuously from two animals in tandem using the same instrument. Improvements in temporal resolution enabled elucidation of rapid changes in extracellular serotonin levels associated with mild stress and circadian rhythms. These dynamics would be difficult or impossible to differentiate using conventional microdialysis sampling rates. PMID:23614776
McGregor, Tracy L.; Van Driest, Sara L.; Brothers, Kyle B.; Bowton, Erica A.; Muglia, Louis J.; Roden, Dan M.
2013-01-01
The Vanderbilt DNA repository, BioVU, links DNA from leftover clinical blood samples to de-identified electronic medical records. After initiating adult sample collection, pediatric extension required consideration of ethical concerns specific to pediatrics and implementation of specialized DNA extraction methods. In the first year of pediatric sample collection, over 11,000 samples were included from individuals younger than 18 years. We compared the pediatric BioVU cohort to the overall Vanderbilt University Medical Center pediatric population and found similar demographic characteristics; however, the BioVU cohort has higher rates of select diseases, medication exposures, and laboratory testing, demonstrating enriched representation of severe or chronic disease. This unbalanced sample accumulation may accelerate research of some cohorts, but also may limit study of relatively benign conditions and the accrual of unaffected and unbiased control samples. BioVU represents a feasible model for pediatric DNA biobanking but involves both ethical and practical considerations specific to the pediatric population. PMID:23281421
Study of Aerothermodynamic Modeling Issues Relevant to High-Speed Sample Return Vehicles
NASA Technical Reports Server (NTRS)
Johnston, Christopher O.
2014-01-01
This paper examines the application of state-of-the-art coupled ablation and radiation simulations to highspeed sample return vehicles, such as those returning from Mars or an asteroid. A defining characteristic of these entries is that the surface recession rates and temperatures are driven by nonequilibrium convective and radiative heating through a boundary layer with significant surface blowing and ablation products. Measurements relevant to validating the simulation of these phenomena are reviewed and the Stardust entry is identified as providing the best relevant measurements. A coupled ablation and radiation flowfield analysis is presented that implements a finite-rate surface chemistry model. Comparisons between this finite-rate model and a equilibrium ablation model show that, while good agreement is seen for diffusion-limited oxidation cases, the finite-rate model predicts up to 50% lower char rates than the equilibrium model at sublimation conditions. Both the equilibrium and finite rate models predict significant negative mass flux at the surface due to sublimation of atomic carbon. A sensitivity analysis to flowfield and surface chemistry rates show that, for a sample return capsule at 10, 12, and 14 km/s, the sublimation rates for C and C3 provide the largest changes to the convective flux, radiative flux, and char rate. A parametric uncertainty analysis of the radiative heating due to radiation modeling parameters indicates uncertainties ranging from 27% at 10 km/s to 36% at 14 km/s. Applying the developed coupled analysis to the Stardust entry results in temperatures within 10% of those inferred from observations, and final recession values within 20% of measurements, which improves upon the 60% over-prediction at the stagnation point obtained through an uncoupled analysis. Emission from CN Violet is shown to be over-predicted by nearly and order-of-magnitude, which is consistent with the results of previous independent analyses. Finally, the coupled analysis is applied to a 14 km/s Earth entry representative of a Mars sample return. Although the radiative heating provides a larger fraction of the total heating, the influence of ablation and radiation on the flowfield are shown to be similar to Stardust.
Search for γ-ray emission from superluminous supernovae with the Fermi-LAT
NASA Astrophysics Data System (ADS)
Renault-Tinacci, N.; Kotera, K.; Neronov, A.; Ando, S.
2018-03-01
We present the first individual and stacking systematic search for γ-ray emission in the GeV band in the directions of 45 superluminous supernovae (SLSNe) with the Fermi Large Area Telescope (LAT). No excess of γ-rays from the SLSN positions was found. We report γ-ray luminosity upper limits and discuss the implication of these results on the origin of SLSNe and, in particular, the scenario of central compact object-aided SNe. From the stacking search, we derived an upper limit at 95% confidence level to the γ-ray luminosity (above 600 MeV) Lγ < 9.1 × 1041 erg s-1 for an assumed E-2 photon spectrum for our full SLSN sample. We conclude that the rate of the neutron stars born with millisecond rotation periods P ≲ 2 ms and B 1012-13 G must be lower than the rate of the observed SLSNe. The luminosity limits obtained on individual sources are also constraining: in particular, SN2013fc, CSS140222, SN2010kd, and PTF12dam can only be born with millisecond periods if B ≲ 1013 G.
Nationwide Databases in Orthopaedic Surgery Research.
Bohl, Daniel D; Singh, Kern; Grauer, Jonathan N
2016-10-01
The use of nationwide databases to conduct orthopaedic research has expanded markedly in recent years. Nationwide databases offer large sample sizes, sampling of patients who are representative of the country as a whole, and data that enable investigation of trends over time. The most common use of nationwide databases is to study the occurrence of postoperative adverse events. Other uses include the analysis of costs and the investigation of critical hospital metrics, such as length of stay and readmission rates. Although nationwide databases are powerful research tools, readers should be aware of the differences between them and their limitations. These include variations and potential inaccuracies in data collection, imperfections in patient sampling, insufficient postoperative follow-up, and lack of orthopaedic-specific outcomes.
Sampling of Protein Folding Transitions: Multicanonical Versus Replica Exchange Molecular Dynamics.
Jiang, Ping; Yaşar, Fatih; Hansmann, Ulrich H E
2013-08-13
We compare the efficiency of multicanonical and replica exchange molecular dynamics for the sampling of folding/unfolding events in simulations of proteins with end-to-end β -sheet. In Go-model simulations of the 75-residue MNK6, we observe improvement factors of 30 in the number of folding/unfolding events of multicanonical molecular dynamics over replica exchange molecular dynamics. As an application, we use this enhanced sampling to study the folding landscape of the 36-residue DS119 with an all-atom physical force field and implicit solvent. Here, we find that the rate-limiting step is the formation of the central helix that then provides a scaffold for the parallel β -sheet formed by the two chain ends.
Rello, Luis; Aramendía, Maite; Belarra, Miguel A; Resano, Martín
2015-01-01
DBS have become a clinical specimen especially adequate for establishing home-based collection protocols. In this work, high-resolution continuum source graphite furnace atomic absorption spectrometry is evaluated for the direct monitoring of Pb in DBS, both as a quantitative tool and a screening method. The development of the screening model is based on the establishment of the unreliability region around the threshold limits, 100 or 50 μg l(-1). More than 500 samples were analyzed to validate the model. The screening method demonstrated high sensitivity (the rate of true positives detected was always higher than 95%), an excellent LOD (1 µg l(-1)) and high throughput (10 min per sample).
NASA Astrophysics Data System (ADS)
Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Krishna, Honnur
Glomerular filtration rate (GFR), the marker of chronic kidney disease can be analyzed by the concentration of cystatin C or creatinine and its clearance in human urine and serum samples. The determination of cystatin C alone as an indicator of GFR does not provide high accuracy, and is more expensive, thus measurement of creatinine has an important role in estimating GFR. We have made an attempt to quantify creatinine based on its pseudoenzyme activity of creatinine in the presence of copper. Creatinine in the presence of copper oxidizes paraphenylenediamine dihydrochloride (PPDD) which couples with dimethylamino benzoicacid (DMAB) giving green colored chromogenic product with maximum absorbance at 710 nm. Kinetic parameters relating this reaction were evaluated. Analytical curves of creatinine by fixed time and rate methods were linear at 8.8-530 μmol L-1 and 0.221-2.65 mmol L-1, respectively. Recovery of creatinine varied from 97.8 to 107.8%. Limit of detection and limit of quantification were 2.55 and 8.52 μmol L-1 respectively whereas Sandell's sensitivity and molar absorption coefficient values were 0.0407 μg cm-2 and 0.1427 × 104 L mol-1 cm-1 respectively. Precision studies showed that within day imprecision was 0.745-1.26% and day-to-day imprecision was 1.55-3.65%. The proposed method was applied to human urine and serum samples and results were validated in accordance with modified Jaffe's procedure. Wide linearity ranges with good recovery, less tolerance from excipients and application of the method to serum and urine samples are the claims which ascertain much advantage to this method.
Hu, Xinxin; Shi, Wei; Cao, Fu; Hu, Guanjiu; Hao, Yingqun; Wei, Si; Wang, Xinru; Yu, Hongxia
2013-02-01
The estrogenic activities of source water from Yangtze River, Huaihe River, Taihu Lake and groundwater in Yangtze River Delta in the dry and wet season were determined by use of reporter gene assays based on African green monkey kidney (CV-1) cell lines. Higher estrogenic activities were observed in the dry season, and the estrogenic potentials in water samples from Taihu Lake were greater than other river basins. None of the samples from groundwater showed estrogen receptor (ER) agonist activity. The 17β-Estradiol (E2) equivalents (EEQs) of water samples in the dry season ranged from 9.41×10(-1) to 1.20×10(1) ng E2 L(-1). In the wet season, EEQs of all the water samples were below the detection limit as 9.00×10(-1) ng E2 L(-1) except for one sample from Huaihe River. The highest contribution of E2 was detected in Yangtze River as 99% of estrogenic activity. Nonylphenol (NP, 100% detection rate) and octylphenol (OP, 100% detection rate) might also be responsible for the estrogenic activities in water sources. Potential health risk induced by the estrogenic chemicals in source water may be posed to the residents through water drinking. Copyright © 2012 Elsevier Ltd. All rights reserved.
Non-destructive Moisture Content Measurement of Bioabsorbable Polymers Used in Medical Implants
NASA Astrophysics Data System (ADS)
Carroll, P. A.; Bell, S. A.; Maxwell, A. S.; Tomlins, P. E.
2012-09-01
Measurements have been made that link moisture content to the degradation of a bioabsorbable polymeric material, poly ( dl-lactide- co-glycolide) (PLGA). Bioabsorbable polymers used in medical implants degrade and are absorbed into the body. In the course of degradation, these polymers absorb water. Progressive non-destructive laboratory measurements of moisture content can be used as a means of tracking changes in these materials over the course of their degradation. Measurements of moisture content were made using a non-destructive microwave resonance instrument. The measurement approach, more usually applied to granular materials, was adapted to measure small, individual solid samples that do not fill the conventional sample volume of the resonator. Using the microwave resonance technique, gains in moisture content were measurable in increasingly degraded samples. The results were confirmed using alternative (destructive) measurements of sample moisture content. The microwave resonance technique offers a non-destructive measurement that can be used to study the degradation characteristics of PLGA. Better understanding of the degradation process can enable the polymer break-down rate to be tailored to match the healing rate of tissue. Non-destructive measurement allows effective study using single rather than multiple samples. This is a strong advantage when novel materials under study may be either expensive or in strictly limited availability.
OXIDATION OF INCONEL 718 IN AIR AT TEMPERATURES FROM 973K TO 1620K.
DOE Office of Scientific and Technical Information (OSTI.GOV)
GREENE,G.A.; FINFROCK,C.C.
2000-10-01
As part of the APT project, it was necessary to quantify the release of tungsten from the APT spallation target during postulated accident conditions in order to develop accident source terms for accident consequence characterization. Experiments with tungsten rods at high temperatures in a flowing steam environment characteristic of postulated accidents revealed that considerable vaporization of the tungsten occurred as a result of reactions with the steam and that the aerosols which formed were readily transported away from the tungsten surfaces, thus exposing fresh tungsten to react with more steam. The resulting tungsten release fractions and source terms were undesirablemore » and it was decided to clad the tungsten target with Inconel 718 in order to protect it from contact with steam during an accident and mitigate the accident source term and the consequences. As part of the material selection criteria, experiments were conducted with Inconel 718 at high temperatures to evaluate the rate of oxidation of the proposed clad material over as wide a temperature range as possible, as well as to determine the high-temperature failure limit of the material. Samples of Inconel 718 were inserted into a preheated furnace at temperatures ranging from 973 K to 1620 K and oxidized in air for varying periods of time. After oxidizing in air at a constant temperature for the prescribed time and then being allowed to cool, the samples would be reweighed to determine their weight gain due to the uptake of oxygen. From these weight gain measurements, it was possible to identify three regimes of oxidation for Inconel 718: a low-temperature regime in which the samples became passivated after the initial oxidation, an intermediate-temperature regime in which the rate of oxidation was limited by diffusion and exhibited a constant parabolic rate dependence, and a high-temperature regime in which material deformation and damage accompanied an accelerated oxidation rate above the parabolic regime. At temperatures below 1173 K, the rate of oxidation of the Inconel 718 surface was found to decrease markedly with time; the parabolic oxidation rate coefficient was not a constant but decreased with time. This was taken to indicate that the oxide film on the surface was having a passivating effect on oxygen transport through the oxide to the underlying metal. For temperatures in the range 1173 K to 1573 K, the time-dependent rate of oxidation as determined once again by weight-gain measurements was found to display the classical parabolic rate behavior, indicating that the rate of transport of reactants through the oxide was controlled by diffusion through the growing oxide layer. Parabolic rate coefficients were determined by least-squares analysis of time-dependent mass-gain data at 1173 K, 1273 K, 1373 K, 1473 K and 1573 K. At temperatures above 1540 K, post test examination of the oxidized samples revealed that the Inconel 718 began to lose strength and to deform. At 1540 K, samples which were suspended from their ends during testing began to demonstrate axial curvature as they lost strength and bowed under their own weight. As the temperatures of the tests were increased, rivulets were seen to appear on the surfaces of the test specimens; damage became severe at 1560 K. Although melting was never observed in any of these tests even up to. 1620 K, it was concluded from these data that the Inconel 718 clad should not be expected to protect the underlying tungsten at temperatures above 1540 K.« less
Kinetically limited weathering at low denudation rates in semi-arid climates
NASA Astrophysics Data System (ADS)
Vanacker, V.; Schoonejans, J.; Opfergelt, S.; Ameijeiras-Marino, Y.; Christl, M.
2016-12-01
On Earth, the Critical Zone supports terrestrial life, being the near-surface environment where interactions between the atmosphere, lithosphere, hydrosphere, and biosphere take place Quantitative understanding of the interaction between mechanical rock breakdown, chemical weathering, and physical erosion is essential for unraveling Earth's biogeochemical cycles. In this study, we explore the role of soil water balance on regulating soil chemical weathering under water deficit regimes. Weathering rates and intensities were evaluated for nine soil profiles located on convex ridge crests of three mountain ranges in the Spanish Betic Cordillera. We present and compare quantitative information on soil weathering, chemical depletion and total denudation that were derived based on geochemical mass balance, 10Be cosmogenic nuclides and U-series disequilibria. Soil production rates determined based on U-series isotopes (238U, 234U, 230Th and 226Ra) are of the same order of magnitude as 10Be-derived denudation rates, suggesting steady state soil thickness, in two out of three sampling sites. The chemical weathering intensities are relatively low (˜5 to 30% of the total denudation of the soil) and negatively correlated with the magnitude of the water deficit in soils. Soil weathering extents increase (nonlinearly) with soil thickness and decrease with increasing surface denudation rates, consistent with kinetically limited or controlled weathering. Our study suggests that soil residence time and water availability limit weathering processes in semi-arid climates, which has not been validated previously with field data. An important implication of this finding is that climatic regimes may strongly regulate soil weathering by modulating soil solute fluxes.
Simonds, Elise C; Handel, Richard W; Archer, Robert P
2008-03-01
This study evaluated the incremental validity of scores from the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) and the Symptom Checklist-90-Revised (SCL-90-R) in a sample of mental health inpatients originally published by Archer, Griffin, and Aiduk (1995). The incremental validity of scores from the SCL-90-R primary symptom dimensions and MMPI-2 Clinical, Content, and Restructured Clinical scales was assessed in a sample of 544 mental health inpatients using conceptually related items from the Brief Psychiatric Rating Scale (BPRS) as criteria. A series of hierarchical multiple regressions indicated that scores from the SCL-90-R primary symptom dimensions exhibited limited incremental validity (Mdn DeltaR(2) = .01, range = 0-.01), whereas scores from MMPI-2 scales contributed additional information in the prediction of ratings on all but one BPRS item (Mdn DeltaR( 2) = .08, range = .04-.12).
Hu, Jianhua; Wright, Fred A
2007-03-01
The identification of the genes that are differentially expressed in two-sample microarray experiments remains a difficult problem when the number of arrays is very small. We discuss the implications of using ordinary t-statistics and examine other commonly used variants. For oligonucleotide arrays with multiple probes per gene, we introduce a simple model relating the mean and variance of expression, possibly with gene-specific random effects. Parameter estimates from the model have natural shrinkage properties that guard against inappropriately small variance estimates, and the model is used to obtain a differential expression statistic. A limiting value to the positive false discovery rate (pFDR) for ordinary t-tests provides motivation for our use of the data structure to improve variance estimates. Our approach performs well compared to other proposed approaches in terms of the false discovery rate.
A Historical Review of Cermet Fuel Development and the Engine Performance Implications
NASA Technical Reports Server (NTRS)
Stewart, Mark E. M.
2015-01-01
This paper reviews test data for cermet fuel samples developed in the 1960's to better quantify Nuclear Thermal Propulsion (NTP) cermet engine performance, and to better understand contemporary fuel testing results. Over 200 cermet (W-UO2) samples were tested by thermally cycling to 2500 deg (2770 K) in hydrogen. The data indicates two issues at high temperatures: the vaporization rate of UO2 and the chemical stability of UO2. The data show that cladding and chemical stabilizers each result in large, order of magnitude improvements in high temperature performance, while other approaches yield smaller, incremental improvements. Data is very limited above 2770 K, and this complicates predictions of engine performance at high Isp. The paper considers how this material performance data translates into engine performance. In particular, the location of maximum temperature within the fuel element and the effect of heat deposition rate are examined.
Jantzi, Sarah C; Almirall, José R
2011-07-01
A method for the quantitative elemental analysis of surface soil samples using laser-induced breakdown spectroscopy (LIBS) was developed and applied to the analysis of bulk soil samples for discrimination between specimens. The use of a 266 nm laser for LIBS analysis is reported for the first time in forensic soil analysis. Optimization of the LIBS method is discussed, and the results compared favorably to a laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) method previously developed. Precision for both methods was <10% for most elements. LIBS limits of detection were <33 ppm and bias <40% for most elements. In a proof of principle study, the LIBS method successfully discriminated samples from two different sites in Dade County, FL. Analysis of variance, Tukey's post hoc test and Student's t test resulted in 100% discrimination with no type I or type II errors. Principal components analysis (PCA) resulted in clear groupings of the two sites. A correct classification rate of 99.4% was obtained with linear discriminant analysis using leave-one-out validation. Similar results were obtained when the same samples were analyzed by LA-ICP-MS, showing that LIBS can provide similar information to LA-ICP-MS. In a forensic sampling/spatial heterogeneity study, the variation between sites, between sub-plots, between samples and within samples was examined on three similar Dade sites. The closer the sampling locations, the closer the grouping on a PCA plot and the higher the misclassification rate. These results underscore the importance of careful sampling for geographic site characterization.
Brief Communication: Buoyancy-Induced Differences in Soot Morphology
NASA Technical Reports Server (NTRS)
Ku, Jerry C.; Griffin, Devon W.; Greenberg, Paul S.; Roma, John
1995-01-01
Reduction or elimination of buoyancy in flames affects the dominant mechanisms driving heat transfer, burning rates and flame shape. The absence of buoyancy produces longer residence times for soot formation, clustering and oxidation. In addition, soot pathlines are strongly affected in microgravity. We recently conducted the first experiments comparing soot morphology in normal and reduced-gravity laminar gas jet diffusion flames. Thermophoretic sampling is a relatively new but well-established technique for studying the morphology of soot primaries and aggregates. Although there have been some questions about biasing that may be induced due to sampling, recent analysis by Rosner et al. showed that the sample is not biased when the system under study is operating in the continuum limit. Furthermore, even if the sampling is preferentially biased to larger aggregates, the size-invariant premise of fractal analysis should produce a correct fractal dimension.
An overabundance of low-density Neptune-like planets
NASA Astrophysics Data System (ADS)
Cubillos, Patricio; Erkaev, Nikolai V.; Juvan, Ines; Fossati, Luca; Johnstone, Colin P.; Lammer, Helmut; Lendl, Monika; Odert, Petra; Kislyakova, Kristina G.
2017-04-01
We present a uniform analysis of the atmospheric escape rate of Neptune-like planets with estimated radius and mass (restricted to Mp < 30 M⊕). For each planet, we compute the restricted Jeans escape parameter, Λ, for a hydrogen atom evaluated at the planetary mass, radius, and equilibrium temperature. Values of Λ ≲ 20 suggest extremely high mass-loss rates. We identify 27 planets (out of 167) that are simultaneously consistent with hydrogen-dominated atmospheres and are expected to exhibit extreme mass-loss rates. We further estimate the mass-loss rates (Lhy) of these planets with tailored atmospheric hydrodynamic models. We compare Lhy to the energy-limited (maximum-possible high-energy driven) mass-loss rates. We confirm that 25 planets (15 per cent of the sample) exhibit extremely high mass-loss rates (Lhy > 0.1 M⌖ Gyr-1), well in excess of the energy-limited mass-loss rates. This constitutes a contradiction, since the hydrogen envelopes cannot be retained given the high mass-loss rates. We hypothesize that these planets are not truly under such high mass-loss rates. Instead, either hydrodynamic models overestimate the mass-loss rates, transit-timing-variation measurements underestimate the planetary masses, optical transit observations overestimate the planetary radii (due to high-altitude clouds), or Neptunes have consistently higher albedos than Jupiter planets. We conclude that at least one of these established estimations/techniques is consistently producing biased values for Neptune planets. Such an important fraction of exoplanets with misinterpreted parameters can significantly bias our view of populations studies, like the observed mass-radius distribution of exoplanets for example.
Otsu, Yo; Bormuth, Volker; Wong, Jerome; Mathieu, Benjamin; Dugué, Guillaume P; Feltz, Anne; Dieudonné, Stéphane
2008-08-30
Two-photon microscopy offers the promise of monitoring brain activity at multiple locations within intact tissue. However, serial sampling of voxels has been difficult to reconcile with millisecond timescales characteristic of neuronal activity. This is due to the conflicting constraints of scanning speed and signal amplitude. The recent use of acousto-optic deflector scanning to implement random-access multiphoton microscopy (RAMP) potentially allows to preserve long illumination dwell times while sampling multiple points-of-interest at high rates. However, the real-life abilities of RAMP microscopy regarding sensitivity and phototoxicity issues, which have so far impeded prolonged optical recordings at high frame rates, have not been assessed. Here, we describe the design, implementation and characterisation of an optimised RAMP microscope. We demonstrate the application of the microscope by monitoring calcium transients in Purkinje cells and cortical pyramidal cell dendrites and spines. We quantify the illumination constraints imposed by phototoxicity and show that stable continuous high-rate recordings can be obtained. During these recordings the fluorescence signal is large enough to detect spikes with a temporal resolution limited only by the calcium dye dynamics, improving upon previous techniques by at least an order of magnitude.
Reflectance-difference spectroscopy of GaAs crystal growth by OMCVD
NASA Astrophysics Data System (ADS)
Colas, Etienne G.; Aspnes, David E.; Bhat, Rajaram J.; Studna, A. A.; Koza, M. A.; Keramidas, Vassilis G.
1990-02-01
This paper summarizes results of our investigations of growth on (001) and (110) GaAs by atmospheric-pressure organometallic chemical vapor deposition (OMCVD). We follow evolutions of surface species to a sensitivity of 0.01 monolayer (ML) on a time scale of 0.1 s under alternating flows of trimethylgallium (TMG) and arsine (AsH3) as functions of partial pressure, sample temperature, and surface orienta-tion. The reaction of TMG with an AsH3-saturated (001) surface is rate-limited by com-petition between desorption and decomposition of TMG molecules chemisorbed to surface lattice sites via an excluded-volume mechanism, while the reaction of AsH3 with the TMG-saturated (001) surface is essentially instantaneous. In contrast, TMG reacts essentially instantaneously with the AsH3 -saturated (110) surface while the AsH3 reaction with the TMG-saturated (110) surface is the rate-limiting step. However, the latter rate is not intrinsic to the AsH3-surface reaction but appears to be determined by desorption of adsorbed species that block active sites.
Sensitivity of a critical tracking task to alcohol impairment
NASA Technical Reports Server (NTRS)
Tennant, J. A.; Thompson, R. R.
1973-01-01
A first order critical tracking task is evaluated for its potential to discriminate between sober and intoxicated performances. Mean differences between predrink and postdrink performances as a function of BAC are analyzed. Quantification of the results shows that intoxicated failure rates of 50% for blood alcohol concentrations (BACs) at or above 0.1%, and 75% for BACs at or above 0.14%, can be attained with no sober failure rates. A high initial rate of learning is observed, perhaps due to the very nature of the task whereby the operator is always pushed to his limit, and the scores approach a stable asymptote after approximately 50 trials. Finally, the implementation of the task as an ignition interlock system in the automobile environment is discussed. It is pointed out that lower critical performance limits are anticipated for the mechanized automotive units because of the introduction of larger hardware and neuromuscular lags. Whether such degradation in performance would reduce the effectiveness of the device or not will be determined in a continuing program involving a broader based sample of the driving population and performance correlations with both BACs and driving proficiency.
Migration Intentions and Illicit Substance Use among Youth in Central Mexico
Marsiglia, Flavio Francisco; Kulis, Stephen; Hoffman, Steven; Calderón-Tena, Carlos Orestes; Becerra, David; Alvarez, Diana
2011-01-01
This study explored intentions to emigrate and substance use among youth (ages 14–24) from a central Mexico state with high emigration rates. Questionnaires were completed in 2007 by 702 students attending a probability sample of alternative secondary schools serving remote or poor communities. Linear and logistic regression analyses indicated that stronger intentions to emigrate predicted greater access to drugs, drug offers, and use of illicit drugs (marijuana, cocaine, inhalants), but not alcohol or cigarettes. Results are related to the healthy migrant theory and its applicability to youth with limited educational opportunities. The study’s limitations are noted. PMID:21955065
C.M. Free; R.M. Landis; J. Grogan; M.D. Schulze; M. Lentini; O. Dunisch; NO-VALUE
2014-01-01
Knowledge of tree age-size relationships is essential towards evaluating the sustainability of harvest regulations that include minimum diameter cutting limits and fixed-length cutting cycles. Although many tropical trees form annual growth rings and can be aged from discs or cores, destructive sampling is not always an option for valuable or threatened species. We...
Technical Report for the Period 1 October 1987 - 30 September 1989
1990-03-01
low pass filter results. -dt dt specifies the sampling rate in seconds. -gin specifies .w file (binary waveform data) input. - gout specifies .w file...waves arriving at moderate incidence angles, * high signal-to-noise ratio (SNR). The following assumptions are made, for simplicity* * additive...spatially uncorrelated noise, * simple signal model, free of refraction and scattering effects. This study is limited to the case of a plane incident P
SwaMURAy - Swapping Memory Unit for Radio Astronomy
NASA Astrophysics Data System (ADS)
Winberg, Simon
2016-03-01
This paper concerns design and performance testing of an HDL module called SwaMURAy that is a configurable, high-speed data sequencing and flow control module serving as an intermediary between data acquisition and subsequent processing stages. While a FIFO suffices for many applications, our case needed a more elaborate solution to overcome legacy design limitations. The SwaMURAy is designed around a system where a block of sampled data is acquired at a fast rate and is then distributed among multiple processing paths to achieve a desired overall processing rate. This architecture provides an effective design pattern around which various software defined radio (SDR) and radio astronomy applications can be built. This solution was partly in response to legacy design restrictions of the SDR platform we used, a difficulty likely experienced by many developers whereby new sampling peripherals are inhibited by legacy characteristics of an underlying reconfigurable platform. Our SDR platform had a planned lifetime of at least five years as a complete redesign and refabrication would be too costly. While the SwaMURAy overcame some performance problems, other problems arose. This paper overviews the SwaMURAy design, performance improvements achieved in an SDR case study, and discusses remaining limitations and workarounds we expect will achieve further improvements.
Estimating Children's Soil/Dust Ingestion Rates through ...
Background: Soil/dust ingestion rates are important variables in assessing children’s health risks in contaminated environments. Current estimates are based largely on soil tracer methodology, which is limited by analytical uncertainty, small sample size, and short study duration. Objectives: The objective was to estimate site-specific soil/dust ingestion rates through reevaluation of the lead absorption dose–response relationship using new bioavailability data from the Bunker Hill Mining and Metallurgical Complex Superfund Site (BHSS) in Idaho, USA. Methods: The U.S. Environmental Protection Agency (EPA) in vitro bioavailability methodology was applied to archived BHSS soil and dust samples. Using age-specific biokinetic slope factors, we related bioavailable lead from these sources to children’s blood lead levels (BLLs) monitored during cleanup from 1988 through 2002. Quantitative regression analyses and exposure assessment guidance were used to develop candidate soil/dust source partition scenarios estimating lead intake, allowing estimation of age-specific soil/dust ingestion rates. These ingestion rate and bioavailability estimates were simultaneously applied to the U.S. EPA Integrated Exposure Uptake Biokinetic Model for Lead in Children to determine those combinations best approximating observed BLLs. Results: Absolute soil and house dust bioavailability averaged 33% (SD ± 4%) and 28% (SD ± 6%), respectively. Estimated BHSS age-specific soil/du
NASA Astrophysics Data System (ADS)
Bezruczko, N.; Fatani, S. S.
2010-07-01
Social researchers commonly compute ordinal raw scores and ratings to quantify human aptitudes, attitudes, and abilities but without a clear understanding of their limitations for scientific knowledge. In this research, common ordinal measures were compared to higher order linear (equal interval) scale measures to clarify implications for objectivity, precision, ontological coherence, and meaningfulness. Raw score gains, residualized raw gains, and linear gains calculated with a Rasch model were compared between Time 1 and Time 2 for observations from two early childhood learning assessments. Comparisons show major inconsistencies between ratings and linear gains. When gain distribution was dense, relatively compact, and initial status near item mid-range, linear measures and ratings were indistinguishable. When Time 1 status was distributed more broadly and magnitude of change variable, ratings were unrelated to linear gain, which emphasizes problematic implications of ordinal measures. Surprisingly, residualized gain scores did not significantly improve ordinal measurement of change. In general, raw scores and ratings may be meaningful in specific samples to establish order and high/low rank, but raw score differences suffer from non-uniform units. Even meaningfulness of sample comparisons, as well as derived proportions and percentages, are seriously affected by rank order distortions and should be avoided.
Use of (137)Cs technique for soil erosion study in the agricultural region of Casablanca in Morocco.
Nouira, A; Sayouty, E H; Benmansour, M
2003-01-01
Accelerated erosion and soil degradation currently cause serious problems to the Oued El Maleh basin (Morocco). Furthermore, there is still only limited information on rates of soil loss for optimising strategies for soil conservation. In the present study we have used the (137)Cs technique to assess the soil erosion rates on an agricultural land in Oued el Maleh basin near Casablanca (Morocco). A small representative agricultural field was selected to investigate the soil degradation required by soil managers in this region. The transect approach was applied for sampling to identify the spatial redistribution of (137)Cs. The spatial variability of (137)Cs inventory has provided evidence of the importance of tillage process and the human effects on the redistribution of (137)Cs. The mean (137)Cs inventory was found about 842 Bq m(-2), this value corresponds to an erosion rate of 82 tha(-1) yr(-1) by applying simplified mass balance model in a preliminary estimation. When data on site characteristics were available, the refined mass balance model was applied to highlight the contribution of tillage effect in soil redistribution. The erosion rate was estimated about 50 tha(-1) yr(-1). The aspects related to the sampling procedures and the models for calculation of erosion rates are discussed.
Photon transitions in Upsilon(2S) and Upsilon(3S) decays.
Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dambasuren, E; Dorjkhaidav, O; Li, J; Menaa, N; Mountain, R; Muramatsu, H; Nandakumar, R; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Bornheim, A; Pappas, S P; Weinstein, A J; Rosner, J L; Briere, R A; Chen, G P; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Crede, V; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Galik, R S; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Hsu, L; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Peterson, D; Pivarski, J; Riley, D; Ryd, A; Sadoff, A J; Schwarthoff, H; Shepherd, M R; Stroiney, S; Sun, W M; Thayer, J G; Urner, D; Wilksen, T; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stoeck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; Thaler, J J; Williams, J; Wiss, J; Edwards, K W; Besson, D; Pedlar, T K; Cronin-Hennessy, D; Gao, K Y; Gong, D T; Kubota, Y; Lang, B W; Li, S Z; Poling, R; Scott, A W; Smith, A; Stepaniak, C J; Dobbs, S; Metreveli, Z; Seth, K K; Tomaradze, A; Zweber, P; Ernst, J; Mahmood, A H; Arms, K; Gan, K K; Severini, H; Asner, D M; Dytman, S A; Love, W; Mehrabyan, S; Mueller, J A; Savinov, V; Li, Z; Lopez, A; Mendez, H; Ramirez, J; Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shibata, E I; Shipsey, I P J; Adams, G S; Chasse, M; Cravey, M; Cummings, J P; Danko, I; Napolitano, J; Park, C S; Park, W; Thayer, J B; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F; Stroynowski, R
2005-01-28
We have studied the inclusive photon spectra in Upsilon(2S) and Upsilon(3S) decays using a large statistics data sample obtained with the CLEO III detector. We present the most precise measurements of electric dipole (E1) photon transition rates and photon energies for Upsilon(2S) --> gammachi(bJ)(1P) and Upsilon(3S) --> gammachi(bJ)(2P) (J = 0, 1, 2). We measure the rate for a rare E1 transition Upsilon(3S) --> gammachi(b0)(1P) for the first time. We also set upper limits on the rates for the hindered magnetic dipole (M1) transitions to the eta(b)(1S) and eta(b)(2S) states.
Davis, Amy J.; Hooten, Mevin B.; Phillips, Michael L.; Doherty, Paul F.
2014-01-01
Evaluation of population dynamics for rare and declining species is often limited to data that are sparse and/or of poor quality. Frequently, the best data available for rare bird species are based on large-scale, population count data. These data are commonly based on sampling methods that lack consistent sampling effort, do not account for detectability, and are complicated by observer bias. For some species, short-term studies of demographic rates have been conducted as well, but the data from such studies are typically analyzed separately. To utilize the strengths and minimize the weaknesses of these two data types, we developed a novel Bayesian integrated model that links population count data and population demographic data through population growth rate (λ) for Gunnison sage-grouse (Centrocercus minimus). The long-term population index data available for Gunnison sage-grouse are annual (years 1953–2012) male lek counts. An intensive demographic study was also conducted from years 2005 to 2010. We were able to reduce the variability in expected population growth rates across time, while correcting for potential small sample size bias in the demographic data. We found the population of Gunnison sage-grouse to be variable and slightly declining over the past 16 years.
Lecomte, Tania; Corbière, Marc; Laisné, François
2006-06-30
Studies investigating self-esteem in individuals with severe mental illness, either as a treatment goal, outcome or correlate to other variables, have increased over the past few years. One of the main difficulties in assessing self-esteem is the assessment itself, often measuring global and stable self-esteem as in the Rosenberg Self-Esteem Scale, or requiring extensive training and long interviews. The present article aims at demonstrating the relevance of the French and English versions of the Self-Esteem Rating Scale-Short Form with individuals with severe mental illness. The instrument's reliability and validity were investigated in a sample of 250 French Canadian college students, 247 British college students and three samples of English- or French-speaking individuals with severe mental illness (N=254, N=150 and N=171). Confirmatory factor analysis revealed that a shorter version of the instrument (20 items), with a positive and a negative self-esteem factor, had a great validity for all the samples studied. The Self-Esteem Rating Scale-Short Form, with its positive and negative self-esteem subscales, appears to be a valid and reliable self-esteem measure for individuals with mental health problems. Limitations of this study and future directions are discussed.
NASA Astrophysics Data System (ADS)
Mok, Angus; Wilson, C. D.; Golding, J.; Warren, B. E.; Israel, F. P.; Serjeant, S.; Knapen, J. H.; Sánchez-Gallego, J. R.; Barmby, P.; Bendo, G. J.; Rosolowsky, E.; van der Werf, P.
2016-03-01
We present a study of the molecular gas properties in a sample of 98 H I - flux selected spiral galaxies within ˜25 Mpc, using the CO J = 3 - 2 line observed with the James Clerk Maxwell Telescope. We use the technique of survival analysis to incorporate galaxies with CO upper limits into our results. Comparing the group and Virgo samples, we find a larger mean H2 mass in the Virgo galaxies, despite their lower mean H I mass. This leads to a significantly higher H2 to H I ratio for Virgo galaxies. Combining our data with complementary Hα star formation rate measurements, Virgo galaxies have longer molecular gas depletion times compared to group galaxies, due to their higher H2 masses and lower star formation rates. We suggest that the longer depletion times may be a result of heating processes in the cluster environment or differences in the turbulent pressure. From the full sample, we find that the molecular gas depletion time has a positive correlation with the stellar mass, indicative of differences in the star formation process between low- and high-mass galaxies, and a negative correlation between the molecular gas depletion time and the specific star formation rate.
Quantitative Analysis of Electron Beam Damage in Organic Thin Films
2017-01-01
In transmission electron microscopy (TEM) the interaction of an electron beam with polymers such as P3HT:PCBM photovoltaic nanocomposites results in electron beam damage, which is the most important factor limiting acquisition of structural or chemical data at high spatial resolution. Beam effects can vary depending on parameters such as electron dose rate, temperature during imaging, and the presence of water and oxygen in the sample. Furthermore, beam damage will occur at different length scales. To assess beam damage at the angstrom scale, we followed the intensity of P3HT and PCBM diffraction rings as a function of accumulated electron dose by acquiring dose series and varying the electron dose rate, sample preparation, and the temperature during acquisition. From this, we calculated a critical dose for diffraction experiments. In imaging mode, thin film deformation was assessed using the normalized cross-correlation coefficient, while mass loss was determined via changes in average intensity and standard deviation, also varying electron dose rate, sample preparation, and temperature during acquisition. The understanding of beam damage and the determination of critical electron doses provides a framework for future experiments to maximize the information content during the acquisition of images and diffraction patterns with (cryogenic) transmission electron microscopy. PMID:28553431
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stack, Andrew G; Raiten, Paolo; Gale, Julian D.
2012-01-01
Mineral growth and dissolution are often treated as occurring via a single, reversible process that governs the rate of reaction. We show that multiple, distinct intermediate states can occur during both growth and dissolution. Specifically, we have used metadynamics, a method to efficiently explore the free energy landscape of a system, coupled to umbrella sampling and reactive flux calculations, to examine the mechanism and rates of attachment and detachment of a barium ion onto a stepped, barite (BaSO4) surface. The activation energies calculated for the rate limiting reactions, which are different for attachment and detachment, precisely match those measured experimentallymore » during both growth and dissolution. These results can potentially explain anomalous, non-steady state mineral reaction rates observed experimentally, and will enable the design of more efficient growth inhibitors and facilitate an understanding of the effect of impurities.« less
Evaluation of third-degree and fourth-degree laceration rates as quality indicators.
Friedman, Alexander M; Ananth, Cande V; Prendergast, Eri; D'Alton, Mary E; Wright, Jason D
2015-04-01
To examine the patterns and predictors of third-degree and fourth-degree laceration in women undergoing vaginal delivery. We identified a population-based cohort of women in the United States who underwent a vaginal delivery between 1998 and 2010 using the Nationwide Inpatient Sample. Multivariable log-linear regression models were developed to account for patient, obstetric, and hospital factors related to lacerations. Between-hospital variability of laceration rates was calculated using generalized log-linear mixed models. Among 7,096,056 women who underwent vaginal delivery in 3,070 hospitals, 3.3% (n=232,762) had a third-degree laceration and 1.1% (n=76,347) had a fourth-degree laceration. In an adjusted model for fourth-degree lacerations, important risk factors included shoulder dystocia and forceps and vacuum deliveries with and without episiotomy. Other demographic, obstetric, medical, and hospital variables, although statistically significant, were not major determinants of lacerations. Risk factors in a multivariable model for third-degree lacerations were similar to those in the fourth-degree model. Regression analysis of hospital rates (n=3,070) of lacerations demonstrated limited between-hospital variation. Risk of third-degree and fourth-degree laceration was most strongly related to operative delivery and shoulder dystocia. Between-hospital variation was limited. Given these findings and that the most modifiable practice related to lacerations would be reduction in operative vaginal deliveries (and a possible increase in cesarean delivery), third-degree and fourth-degree laceration rates may be a quality metric of limited utility.
Miao, Zewei; Xu, Ming; Lathrop, Richard G; Wang, Yufei
2009-02-01
A review of the literature revealed that a variety of methods are currently used for fitting net assimilation of CO2-chloroplastic CO2 concentration (A-Cc) curves, resulting in considerable differences in estimating the A-Cc parameters [including maximum ribulose 1.5-bisphosphate carboxylase/oxygenase (Rubisco) carboxylation rate (Vcmax), potential light saturated electron transport rate (Jmax), leaf dark respiration in the light (Rd), mesophyll conductance (gm) and triose-phosphate utilization (TPU)]. In this paper, we examined the impacts of fitting methods on the estimations of Vcmax, Jmax, TPU, Rd and gm using grid search and non-linear fitting techniques. Our results suggested that the fitting methods significantly affected the predictions of Rubisco-limited (Ac), ribulose 1,5-bisphosphate-limited (Aj) and TPU-limited (Ap) curves and leaf photosynthesis velocities because of the inconsistent estimate of Vcmax, Jmax, TPU, Rd and gm, but they barely influenced the Jmax : Vcmax, Vcmax : Rd and Jmax : TPU ratio. In terms of fitting accuracy, simplicity of fitting procedures and sample size requirement, we recommend to combine grid search and non-linear techniques to directly and simultaneously fit Vcmax, Jmax, TPU, Rd and gm with the whole A-Cc curve in contrast to the conventional method, which fits Vcmax, Rd or gm first and then solves for Vcmax, Jmax and/or TPU with V(cmax), Rd and/or gm held as constants.
2010-01-01
Background Diagnostic options for pulmonary tuberculosis in resource-poor settings are commonly limited to smear microscopy. We investigated whether bleach concentration by sedimentation and sputum cytology analysis (SCA) increased the positivity rate of smear microscopy for smear-positive tuberculosis. Methods We did a prospective diagnostic study in a Médecins Sans Frontières-supported hospital in Mindouli, Republic of Congo. Three sputum samples were obtained from 280 consecutive pulmonary tuberculosis suspects, and were processed according to WHO guidelines for direct smear microscopy. The remainder of each sputum sample was homogenised with 2.6% bleach, sedimented overnight, smeared, and examined blinded to the direct smear result for acid-fast bacilli (AFB). All direct smears were assessed for quality by SCA. If a patient produced fewer than three good-quality sputum samples, further samples were requested. Sediment smear examination was performed independently of SCA result on the corresponding direct smear. Positivity rates were compared using McNemar's test. Results Excluding SCA, 43.2% of all patients were diagnosed as positive on direct microscopy of up to three samples. 47.9% were diagnosed on sediment microscopy, with 48.2% being diagnosed on direct microscopy, sediment microscopy, or both. The positivity rate increased from 43.2% to 47.9% with a case definition of one positive smear (≥1 AFB/100 high power fields) of three, and from 42.1% to 43.9% with two positive smears. SCA resulted in 87.9% of patients producing at least two good-quality sputum samples, with 75.7% producing three or more. Using a case definition of one positive smear, the incremental yield of bleach sedimentation was 14/121, or 11.6% (95% CI 6.5-18.6, p = 0.001) and in combination with SCA was 15/121, or 12.4% (95% CI 7.1-19.6, p = 0.002). Incremental yields with two positive smears were 5/118, or 4.2% (95% CI 1.4-9.6, p = 0.062) and 7/118, or 5.9% (95% CI 2.4-11.8, p = 0.016), respectively. Conclusions The combination of bleach sedimentation and SCA resulted in significantly increased microscopy positivity rates with a case definition of either one or two positive smears. Implementation of bleach sedimentation led to a significant increase in the diagnosis of smear-positive patients. Implementation of SCA did not result in significantly increased diagnosis of tuberculosis, but did result in improved sample quality. Requesting extra sputum samples based on SCA results, combined with bleach sedimentation, could significantly increase the detection of smear-positive patients if routinely implemented in resource-limited settings where gold standard techniques are not available. We recommend that a pilot phase is undertaken before routine implementation to determine the impact in a particular context. PMID:20858253
Beresford, N A; Barnett, C L; Gashchak, S; Maksimenko, A; Guliaichenko, E; Wood, M D; Izquierdo, M
2018-02-27
This study addresses a significant data deficiency in the developing environmental protection framework of the International Commission on Radiological Protection, namely a lack of radionuclide transfer data for some of the Reference Animals and Plants (RAPs). It is also the first study that has sampled such a wide range of species (invertebrates, plants, amphibians and small mammals) from a single terrestrial site in the Chernobyl Exclusion Zone (CEZ). Samples were collected in 2014 from the 0.4 km 2 sampling site, located 5 km west of the Chernobyl Nuclear Power complex. We report radionuclide ( 137 Cs, 90 Sr, 241 Am and Pu-isotopes) and stable element concentrations in wildlife and soil samples and use these to determine whole organism-soil concentration ratios and absorbed dose rates. Increasingly, stable element analyses are used to provide transfer parameters for radiological models. The study described here found that for both Cs and Sr the transfer of the stable element tended to be lower than that of the radionuclide; this is the first time that this has been demonstrated for Sr, though it is in agreement with limited evidence previously reported for Cs. Studies reporting radiation effects on wildlife in the CEZ generally relate observations to ambient dose rates determined using handheld dose meters. For the first time, we demonstrate that ambient dose rates may underestimate the actual dose rate for some organisms by more than an order of magnitude. When reporting effects studies from the CEZ, it has previously been suggested that the area has comparatively low natural background dose rates. However, on the basis of data reported here, dose rates to wildlife from natural background radionuclides within the CEZ are similar to those in many areas of Europe. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Ross, D.S.; Shanley, J.B.; Campbell, J.L.; Lawrence, G.B.; Bailey, S.W.; Likens, G.E.; Wemple, B.C.; Fredriksen, G.; Jamison, A.E.
2012-01-01
Nitrogen export from small forested watersheds is known to be affected by N deposition but with high regional variability. We studied 10 headwater catchments in the northeastern United States across a gradient of N deposition (5.4 - 9.4 kg ha -1 yr -1) to determine if soil nitrification rates could explain differences in stream water NO 3 - export. Average annual export of two years (October 2002 through September 2004) varied from 0.1 kg NO 3 --N ha -1 yr -1 at Cone Pond watershed in New Hampshire to 5.1 kg ha -1 yr -1 at Buck Creek South in the western Adirondack Mountains of New York. Potential net nitrification rates and relative nitrification (fraction of inorganic N as NO 3 -) were measured in Oa or A soil horizons at 21-130 sampling points throughout each watershed. Stream NO 3 - export was positively related to nitrification rates (r 2 = 0.34, p = 0.04) and the relative nitrification (r 2 = 0.37, p = 0.04). These relationships were much improved by restricting consideration to the 6 watersheds with a higher number of rate measurements (59-130) taken in transects parallel to the streams (r 2 of 0.84 and 0.70 for the nitrification rate and relative nitrification, respectively). Potential nitrification rates were also a better predictor of NO 3 - export when data were limited to either the 6 sampling points closest to the watershed outlet (r 2 = 0.75) or sampling points <250 m from the watershed outlet (r 2 = 0.68). The basal area of conifer species at the sampling plots was negatively related to NO 3 - export. These spatial relationships found here suggest a strong influence of near-stream and near-watershed-outlet soils on measured stream NO 3 - export. Copyright 2012 by the American Geophysical Union.
Ellis, Robert J; Zhu, Bilei; Koenig, Julian; Thayer, Julian F; Wang, Ye
2015-09-01
As the literature on heart rate variability (HRV) continues to burgeon, so too do the challenges faced with comparing results across studies conducted under different recording conditions and analysis options. Two important methodological considerations are (1) what sampling frequency (SF) to use when digitizing the electrocardiogram (ECG), and (2) whether to interpolate an ECG to enhance the accuracy of R-peak detection. Although specific recommendations have been offered on both points, the evidence used to support them can be seen to possess a number of methodological limitations. The present study takes a new and careful look at how SF influences 24 widely used time- and frequency-domain measures of HRV through the use of a Monte Carlo-based analysis of false positive rates (FPRs) associated with two-sample tests on independent sets of healthy subjects. HRV values from the first sample were calculated at 1000 Hz, and HRV values from the second sample were calculated at progressively lower SFs (and either with or without R-peak interpolation). When R-peak interpolation was applied prior to HRV calculation, FPRs for all HRV measures remained very close to 0.05 (i.e. the theoretically expected value), even when the second sample had an SF well below 100 Hz. Without R-peak interpolation, all HRV measures held their expected FPR down to 125 Hz (and far lower, in the case of some measures). These results provide concrete insights into the statistical validity of comparing datasets obtained at (potentially) very different SFs; comparisons which are particularly relevant for the domains of meta-analysis and mobile health.
Water Retention and Rheology of Ti-doped, Synthetic Olivine
NASA Astrophysics Data System (ADS)
Faul, U.; Jackson, I.; Fitz Gerald, J. D.
2012-12-01
Upper mantle flow laws are currently based almost entirely on experiments with olivine from San Carlos in Arizona. Synthetically produced olivine enables the exploration of the effects of trace elements on the rheology. We have conducted a range of experiments in a gas medium apparatus with solution-gelation derived olivine that show that titanium is the most effective in binding water in the olivine structure. The FTIR signature of this structurally bound water is most similar to that of water-undersaturated natural olivine with absorption bands at 3575 and 3525 cm-1. Water added, titanium-free solgel contains little water after hotpressing and shows adsorption bands at wavenumbers near 3200 cm-1. Noble metal capsules such as Pt or AuPd, providing more oxidizing conditions, are more effective in retaining water. Experiments with NiFe-lined welded Pt capsules retain no more water than NiFe lined samples without Pt capsule. Water retention is, however, again dependent on trace element content, with Ti doped samples containing tens of ppm after hotpressing. By comparison undoped samples run under the same conditions contain little water, again with different FTIR spectra to Ti-doped samples. Our experiments suggest that Ti by itself, or with water contents at the FTIR detection limit enhances diffusion creep rates relative to undoped, dry solgel olivine. Water contents around 10 ppm in NiFe wrapped samples show an enhancement of strain rates of more than one order of magnitude. The addition of Ti, together with the presence of water, also enhances grain growth. For more coarse-grained samples in the dislocation creep regime the enhancement of the stain rate as a function of water content is approximately consistent with the flow laws of Hirth and Kohlstedt (2003).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Shuhuai; Bakajin, Olgica
2007-08-01
Using a microfluidic laminar flow mixer designed for studies of protein folding kinetics, we demonstrate a mixing time of 1 +/- 1 micros with sample consumption on the order of femtomoles. We recognize two limitations of previously proposed designs: (1) size and shape of the mixing region, which limits mixing uniformity and (2) the formation of Dean vortices at high flow rates, which limits the mixing time. We address these limitations by using a narrow shape-optimized nozzle and by reducing the bend of the side channel streamlines. The final design, which combines both of these features, achieves the best performance.more » We quantified the mixing performance of the different designs by numerical simulation of coupled Navier-Stokes and convection-diffusion equations and experiments using fluorescence resonance energy-transfer (FRET)-labeled DNA.« less
Psychological Resilience and Depressive Symptoms in Older Adults Diagnosed with Post-polio Syndrome
Pierini, Diana; Stuifbergen, Alexa
2012-01-01
Depression is a serious co-morbidity in persons with disability, yet few studies have focused on depressive symptoms in persons aging with post-polio syndrome (PPS). We used a resilience conceptual framework that focused on patient psychosocial strengths to investigate the relationship between psychological resilience factors (acceptance, self-efficacy, personal resources, interpersonal relationships, self-rated health, spiritual growth, and stress management) and depressive symptoms in a large sample (n = 630) of persons over age 65 who were diagnosed with PPS. A higher percentage (40%) of the sample scored ≥ 10 on the CES-D 10 than was previously cited in other studies; however, 53% of the sample had good or excellent self-rated health, suggesting psychological resilience. Depression scores were regressed on seven selected resilience factors after controlling for functional limitations. Four of the seven variables accounted for 30% of the variance in depressive symptoms with spiritual growth representing the main predictor (β = −.26). The implications for rehabilitation nurses in developing a patient-strengths perspective in the assessment and counseling of individuals aging with PPS are discussed. PMID:20681392
Kirs, Marek; Caffaro-Filho, Roberto A; Wong, Mayee; Harwood, Valerie J; Moravcik, Philip; Fujioka, Roger S
2016-11-15
Identification of sources of fecal contaminants is needed to (i) determine the health risk associated with recreational water use and (ii) implement appropriate management practices to mitigate this risk and protect the environment. This study evaluated human-associated Bacteroides spp. (HF183TaqMan) and human polyomavirus (HPyV) markers for host sensitivity and specificity using human and animal fecal samples collected in Hawaii. The decay rates of those markers and indicator bacteria were identified in marine and freshwater microcosms exposed and not exposed to sunlight, followed by field testing of the usability of the molecular markers. Both markers were strongly associated with sewage, although the cross-reactivity of the HF183TaqMan (also present in 82% of canine [n = 11], 30% of mongoose [n = 10], and 10% of feline [n = 10] samples) needs to be considered. Concentrations of HF183TaqMan in human fecal samples exceeded those in cross-reactive animals at least 1,000-fold. In the absence of sunlight, the decay rates of both markers were comparable to the die-off rates of enterococci in experimental freshwater and marine water microcosms. However, in sunlight, the decay rates of both markers were significantly lower than the decay rate of enterococci. While both markers have their individual limitations in terms of sensitivity and specificity, these limitations can be mitigated by using both markers simultaneously; ergo, this study supports the concurrent use of HF183TaqMan and HPyV markers for the detection of sewage contamination in coastal and inland waters in Hawaii. This study represents an in-depth characterization of microbial source tracking (MST) markers in Hawaii. The distribution and concentrations of HF183TaqMan and HPyV markers in human and animal fecal samples and in wastewater, coupled with decay data obtained from sunlight-exposed and unexposed microcosms, support the concurrent application of HF183TaqMan and HPyV markers for sewage contamination detection in Hawaii waters. Both markers are more conservative and more specific markers of sewage than fecal indicator bacteria (enterococci and Escherichia coli). Analysis of HF183TaqMan (or newer derivatives) is recommended for inclusion in future epidemiological studies concerned with beach water quality, while better concentration techniques are needed for HPyV. Such epidemiological studies can be used to develop new recreational water quality criteria, which will provide direct information on the absence or presence of sewage contamination in water samples as well as reliable measurements of the risk of waterborne disease transmission to swimmers. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Holding effects on coliform enumeration in drinking water samples.
McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C
1985-01-01
Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877
Lee, Eun Gyung; Magrm, Rana; Kusti, Mohannad; Kashon, Michael L; Guffey, Steven; Costas, Michelle M; Boykin, Carie J; Harper, Martin
2017-01-01
This study was to determine occupational exposures to formaldehyde and to compare concentrations of formaldehyde obtained by active and passive sampling methods. In one pathology and one histology laboratories, exposure measurements were collected with sets of active air samplers (Supelco LpDNPH tubes) and passive badges (ChemDisk Aldehyde Monitor 571). Sixty-six sample pairs (49 personal and 17 area) were collected and analyzed by NIOSH NMAM 2016 for active samples and OSHA Method 1007 (using the manufacturer's updated uptake rate) for passive samples. All active and passive 8-hr time-weighted average (TWA) measurements showed compliance with the OSHA permissible exposure limit (PEL-0.75 ppm) except for one passive measurement, whereas 78% for the active and 88% for the passive samples exceeded the NIOSH recommended exposure limit (REL-0.016 ppm). Overall, 73% of the passive samples showed higher concentrations than the active samples and a statistical test indicated disagreement between two methods for all data and for data without outliers. The OSHA Method cautions that passive samplers should not be used for sampling situations involving formalin solutions because of low concentration estimates in the presence of reaction products of formaldehyde and methanol (a formalin additive). However, this situation was not observed, perhaps because the formalin solutions used in these laboratories included much less methanol (3%) than those tested in the OSHA Method (up to 15%). The passive samplers in general overestimated concentrations compared to the active method, which is prudent for demonstrating compliance with an occupational exposure limit, but occasional large differences may be a result of collecting aerosolized droplets or splashes on the face of the samplers. In the situations examined in this study the passive sampler generally produces higher results than the active sampler so that a body of results from passive samplers demonstrating compliance with the OSHA PEL would be a valid conclusion. However, individual passive samples can show lower results than a paired active sampler so that a single result should be treated with caution.
Porto, Paolo; Walling, Des E; Alewell, Christine; Callegari, Giovanni; Mabit, Lionel; Mallimo, Nicola; Meusburger, Katrin; Zehringer, Markus
2014-12-01
Soil erosion and both its on-site and off-site impacts are increasingly seen as a serious environmental problem across the world. The need for an improved evidence base on soil loss and soil redistribution rates has directed attention to the use of fallout radionuclides, and particularly (137)Cs, for documenting soil redistribution rates. This approach possesses important advantages over more traditional means of documenting soil erosion and soil redistribution. However, one key limitation of the approach is the time-averaged or lumped nature of the estimated erosion rates. In nearly all cases, these will relate to the period extending from the main period of bomb fallout to the time of sampling. Increasing concern for the impact of global change, particularly that related to changing land use and climate change, has frequently directed attention to the need to document changes in soil redistribution rates within this period. Re-sampling techniques, which should be distinguished from repeat-sampling techniques, have the potential to meet this requirement. As an example, the use of a re-sampling technique to derive estimates of the mean annual net soil loss from a small (1.38 ha) forested catchment in southern Italy is reported. The catchment was originally sampled in 1998 and samples were collected from points very close to the original sampling points again in 2013. This made it possible to compare the estimate of mean annual erosion for the period 1954-1998 with that for the period 1999-2013. The availability of measurements of sediment yield from the catchment for parts of the overall period made it possible to compare the results provided by the (137)Cs re-sampling study with the estimates of sediment yield for the same periods. In order to compare the estimates of soil loss and sediment yield for the two different periods, it was necessary to establish the uncertainty associated with the individual estimates. In the absence of a generally accepted procedure for such calculations, key factors influencing the uncertainty of the estimates were identified and a procedure developed. The results of the study demonstrated that there had been no significant change in mean annual soil loss in recent years and this was consistent with the information provided by the estimates of sediment yield from the catchment for the same periods. The study demonstrates the potential for using a re-sampling technique to document recent changes in soil redistribution rates. Copyright © 2014. Published by Elsevier Ltd.
Larsson, Gerry; Sandahl, Christer; Söderhjelm, Teresa; Sjövold, Endre; Zander, Ann
2017-02-01
The aim was to evaluate effects of leadership courses based on the developmental leadership model at the leadership behavioral level. A longitudinal design was employed with assessments before, one and six months after the leadership courses. The sample consisted of 59 leaders who made self-ratings and were rated by at least three subordinates on each occasion. Leadership behaviors were measured with the Developmental Leadership Questionnaire (DLQ). A limited increase of favorable leadership behaviors and a significant reduction of unfavorable leadership behaviors were found, particularly according to the subordinates' ratings. A cluster analysis yielded three meaningful leader profiles and showed that this pattern was found in all three profiles, irrespective of how favorably they were rated before the onset of the intervention. © 2016 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
Stefan-van Staden, Raluca-Ioana; Bokretsion, Rahel Girmai; van Staden, Jacobus F; Aboul-Enein, Hassan Y
2006-01-01
Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).
Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi
2010-01-01
A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.
Xu, Ning; Chamberlin, Rebecca M.; Thompson, Pam; ...
2017-10-07
This study has demonstrated that bulk plutonium chemical analysis can be performed at small scales (\\50 mg material) through three case studies. Analytical methods were developed for ICP-OES and ICP-MS instruments to measure trace impurities and gallium content in plutonium metals with comparable or improved detection limits, measurement accuracy and precision. In two case studies, the sample size has been reduced by 109, and in the third case study, by as much as 50009, so that the plutonium chemical analysis can be performed in a facility rated for lower-hazard and lower-security operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Ning; Chamberlin, Rebecca M.; Thompson, Pam
This study has demonstrated that bulk plutonium chemical analysis can be performed at small scales (\\50 mg material) through three case studies. Analytical methods were developed for ICP-OES and ICP-MS instruments to measure trace impurities and gallium content in plutonium metals with comparable or improved detection limits, measurement accuracy and precision. In two case studies, the sample size has been reduced by 109, and in the third case study, by as much as 50009, so that the plutonium chemical analysis can be performed in a facility rated for lower-hazard and lower-security operations.
Hydrocarbon biodegradation in hypersaline environments.
Ward, D M; Brock, T D
1978-02-01
When mineral oil, hexadecane, and glutamate were added to natural samples of varying salinity (3.3 to 28.4%) from salt evaporation ponds and Great Salt Lake, Utah, rates of metabolism of these compounds decreased as salinity increased. Rate limitations did not appear to relate to low oxygen levels or to the availability of organic nutrients. Some oxidation of l-[U-C]glutamic acid occurred even at extreme salinities, whereas oxidation of [1-C]hexadecane was too low to be detected. Gas chromatographic examination of hexane-soluble components of tar samples from natural seeps at Rozel Point in Great Salt Lake demonstrated no evidence of biological oxidation of isoprenoid alkanes subject to degradation in normal environments. Some hexane-soluble components of the same tar were altered by incubation in a low-salinity enrichment culture inoculated with garden soil. Attempts to enrich for microorganisms in saline waters able to use mineral oil as a sole source of carbon and energy were successful below, but not above, about 20% salinity. This study strongly suggests a general reduction of metabolic rate at extreme salinities and raises doubt about the biodegradation of hydrocarbons in hypersaline environments.
Concentrations and risks of organic and metal contaminants in Eurasian caviar.
Wang, Wei; Batterman, Stuart; Chernyak, Sergei; Nriagu, Jerome
2008-09-01
Caviar (fish roe of sturgeon) may contain high levels of contaminants. Concentrations of organic contaminants, including DDT, hexachlorocyclohexanes (HCHs), polychlorinated biphenyls (PCBs), brominated flame retardants (polybrominated diphenyl ethers (PBDEs)), and 23 metals were measured in three species of caviar (Acipenser Huso huso, Acipenser gueldenstaedti, and Acipenser stellatus) imported from Azerbaijan, Bulgaria, Iran, and Russia just prior to the 2006 export ban. PCB concentrations averaged 15.4+/-25.8 ng/g wet weight basis (wwt), DDT averaged 79+/-139 ng/g wwt, arsenic (As) averaged 960+/-486 ng/g, and PBDEs were detected in all samples. Cluster analyses grouped most of the Huso huso samples together, while most of the remaining clusters were grouped by origin. Trends of contaminant concentrations, estimated by incorporating data from earlier studies, show that PCB and DDT levels have been declining since 1978, and HCH levels since 2000. The maximum allowable daily consumption rate of caviar is limited by PCBs, DDTs and As. While the health risks are uncertain since consumption rates are unknown, declining concentrations and low consumption rates suggest that health advisories for caviar are unwarranted.
NASA Astrophysics Data System (ADS)
van Velzen, S.
2018-01-01
The tidal disruption of a star by a massive black hole is expected to yield a luminous flare of thermal emission. About two dozen of these stellar tidal disruption flares (TDFs) may have been detected in optical transient surveys. However, explaining the observed properties of these events within the tidal disruption paradigm is not yet possible. This theoretical ambiguity has led some authors to suggest that optical TDFs are due to a different process, such as a nuclear supernova or accretion disk instabilities. Here we present a test of a fundamental prediction of the tidal disruption event scenario: a suppression of the flare rate due to the direct capture of stars by the black hole. Using a recently compiled sample of candidate TDFs with black hole mass measurements, plus a careful treatment of selection effects in this flux-limited sample, we confirm that the dearth of observed TDFs from high-mass black holes is statistically significant. All the TDF impostor models we consider fail to explain the observed mass function; the only scenario that fits the data is a suppression of the rate due to direct captures. We find that this suppression can explain the low volumetric rate of the luminous TDF candidate ASASSN-15lh, thus supporting the hypothesis that this flare belongs to the TDF family. Our work is the first to present the optical TDF luminosity function. A steep power law is required to explain the observed rest-frame g-band luminosity, {dN}/{{dL}}g\\propto {L}g-2.5. The mean event rate of the flares in our sample is ≈ 1× {10}-4 galaxy‑1 yr‑1, consistent with the theoretically expected tidal disruption rate.
Nelson, Philip H.; Ewald, Shauna M.; Santus, Stephen L.; Trainor, Patrick K.
2010-01-01
Gas, oil, and water production data were compiled from selected wells in four gas fields in rocks of Late Cretaceous age in southwestern Wyoming. This study is one of a series of reports examining fluid production from tight-gas reservoirs, which are characterized by low permeability, low porosity, and the presence of clay minerals in pore space. Production from each well is represented by two samples spaced five years apart, the first sample typically taken two years after commencement of production. For each producing interval, summary diagrams of oil versus gas and water versus gas production show fluid production rates, the change in rates during five years, the water-gas and oil-gas ratios, and the fluid type. These diagrams permit well-to-well and field-to-field comparisons. Fields producing water at low rates (water dissolved in gas in the reservoir) can be distinguished from fields producing water at moderate or high rates, and the water-gas ratios are quantified. The ranges of first-sample gas rates in Pinedale field and Jonah field are quite similar, and the average gas production rate for the second sample, taken five years later, is about one-half that of the first sample for both fields. Water rates are generally substantially higher in Pinedale than in Jonah, and water-gas ratios in Pinedale are roughly a factor of ten greater in Pinedale than in Jonah. Gas and water production rates from each field are fairly well grouped, indicating that Pinedale and Jonah fields are fairly cohesive gas-water systems. Pinedale field appears to be remarkably uniform in its flow behavior with time. Jonah field, which is internally faulted, exhibits a small spread in first-sample production rates. In the Greater Wamsutter field, gas production from the upper part of the Almond Formation is greater than from the main part of the Almond. Some wells in the main and the combined (upper and main parts) Almond show increases in water production with time, whereas increases in water production are rare in the upper part of the Almond, and a higher percentage of wells in the upper part of the Almond show water decreasing at the same rate as gas than in the main or combined parts of the Almond. In Stagecoach Draw field, the gas production rate after five years is about one-fourth that of the first sample, whereas in Pinedale, Jonah, and Greater Wamsutter fields, the production rate after five years is about one-half that of the first sample. The more rapid gas decline rate seems to be the outstanding feature distinguishing Stagecoach Draw field, which is characterized as a conventional field, from Pinedale, Jonah, and Greater Wamsutter fields, which are generally characterized as tight-gas accumulations. Oil-gas ratios are fairly consistent within Jonah, Pinedale, and Stagecoach Draw fields, suggesting similar chemical composition and pressure-temperature conditions within each field, and are less than the 20 bbl/mmcf upper limit for wet gas. However, oil-gas ratios vary considerably from one area to another in the Greater Wamsutter field, demonstrating a lack of commonality in either chemistry or pressure-temperature conditions among the six areas. In all wells in all four fields examined here, water production commences with gas production-there are no examples of wells with water-free production and no examples where water production commences after first-sample gas production. The fraction of records with water production higher in the second sample than in the first sample varies from field to field, with Pinedale field showing the lowest percentage of such cases and Jonah field showing the most. Most wells have water-gas ratios exceeding the amount that could exist dissolved in gas at reservoir pressure and temperature.
Fernández-Ramos, C; Ballesteros, O; Blanc, R; Zafra-Gómez, A; Jiménez-Díaz, I; Navalón, A; Vílchez, J L
2012-08-30
In the present paper, we developed an accurate method for the analysis of alcohol sulfates (AS) in wastewater samples from wastewater treatment plant (WWTP) influents and effluents. Although many methodologies have been published in the literature concerning the study of anionic surfactants in environmental samples, at present, the number of analytical methodologies that focus in the determination of AS by gas chromatography in the different environmental compartments is limited. The reason for this is that gas chromatography-mass spectrometry (GC-MS) technique requires a previous hydrolysis reaction followed by derivatization reactions. In the present work, we proposed a new procedure in which the hydrolysis and derivatization reactions take place in one single step and AS are directly converted to trimethylsilyl derivatives. The main factors affecting solid-phase extraction (SPE), hydrolysis/derivatization and GC-MS procedures were accurately optimised. Quantification of the target compounds was performed by using GC-MS in selected ion monitoring (SIM) mode. The limits of detection (LOD) obtained ranged from 0.2 to 0.3 μg L(-1), and limits of quantification (LOQ) from 0.5 to 1.0 μg L(-1), while inter- and intra-day variability was under 5%. A recovery assay was also carried out. Recovery rates for homologues in spiked samples ranged from 96 to 103%. The proposed method was successfully applied for the determination of anionic surfactants in wastewater samples from one WWTP located in Granada (Spain). Concentration levels for the homologues up to 39.4 μg L(-1) in influent and up to 8.1 μg L(-1) in effluent wastewater samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Direct sampling of chemical weapons in water by photoionization mass spectrometry.
Syage, Jack A; Cai, Sheng-Suan; Li, Jianwei; Evans, Matthew D
2006-05-01
The vulnerability of water supplies to toxic contamination calls for fast and effective means for screening water samples for multiple threats. We describe the use of photoionization (PI) mass spectrometry (MS) for high-speed, high-throughput screening and molecular identification of chemical weapons (CW) threats and other hazardous compounds. The screening technology can detect a wide range of compounds at subacute concentrations with no sample preparation and a sampling cycle time of approximately 45 s. The technology was tested with CW agents VX, GA, GB, GD, GF, HD, HN1, and HN3, in addition to riot agents and precursors. All are sensitively detected and give simple PI mass spectra dominated by the parent ion. The target application of the PI MS method is as a routine, real-time early warning system for CW agents and other hazardous compounds in air and in water. In this work, we also present comprehensive measurements for water analysis and report on the system detection limits, linearity, quantitation accuracy, and false positive (FP) and false negative rates for concentrations at subacute levels. The latter data are presented in the form of receiver operating characteristic curves of the form of detection probability P(D) versus FP probability P(FP). These measurements were made using the CW surrogate compounds, DMMP, DEMP, DEEP, and DIMP. Method detection limits (3sigma) obtained using a capillary injection method yielded 1, 6, 3, and 2 ng/mL, respectively. These results were obtained using 1-microL injections of water samples without any preparation, corresponding to mass detection limits of 1, 6, 3, and 2 pg, respectively. The linear range was about 3-4 decades and the dynamic range about 4-5 decades. The relative standard deviations were generally <10% at CW subacute concentrations levels.
Wadhwa, Sham Kumar; Tuzen, Mustafa; Gul Kazi, Tasneem; Soylak, Mustafa
2013-11-15
Vanadium(V) ions as 8-hydroxyquinoline chelates were loaded on multiwalled carbon nanotubes (MWNTs) in a mini chromatographic column. Vanadium was determined by graphite furnace atomic absorption spectrometry (GFAAS). Various analytical parameters including pH of the working solutions, amounts of 8-hydroxyquinoline, eluent type, sample volume, and flow rates were investigated. The effects of matrix ions and some transition metals were also studied. The column can be reused 250 times without any loss in its sorption properties. The preconcentration factor was found as 100. Detection limit (3 s) and limit of quantification (10 s) for the vanadium in the optimal conditions were observed to be 0.012 µg L(-1) and 0.040 μg L(-1), respectively. The capacity of adsorption was 9.6 mg g(-1). Relative standard deviation (RSD) was found to be 5%. The validation of the method was confirmed by using NIST SRM 1515 Apple leaves, NIST SRM 1570a Spinach leaves and GBW 07605 Tea certified reference materials. The procedure was applied to the determination of vanadium in tap water and bottled drinking water samples. The procedure was also successfully applied to microwave digested food samples including black tea, coffee, tomato, cabbage, zucchini, apple and chicken samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Taghvimi, Arezou; Hamishehkar, Hamed; Ebrahimi, Mahmoud
2016-01-15
This paper reports on a method based on magnetic solid phase extraction (MSPE) for the determination of pseudoephedrine. Magnetic nanographene oxide (MNGO) was applied as a new adsorbent for the extraction of pseudoephedrine from urine samples. Synthesis of MNGO was characterized by Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), powder X-ray diffraction (XRD), and vibrating sample magnetometer (VSM). The main factors influencing extraction efficiency, including the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, ionic strength of extraction medium, and agitation rate, were investigated and optimized. Under optimized extraction conditions, a good linearity was observed in the range of 100-2000ng/mL with a correlation coefficient of 0.9908 (r(2)). Limit of detection (LOD) and limit of quantification (LOQ) were 25 and 82.7ng/mL, respectively. Inter-day and intra-day precision and accuracy were 6.01 and 0.34 (%), and 8.70 and 0.29 (%), respectively. The method was applied for the determination of pseudoephedrine in urine samples of volunteers receiving pseudoephedrine with the recovery of 96.42. It was concluded that the proposed method can be applied in diagnostic clinics. Copyright © 2015 Elsevier B.V. All rights reserved.
An Infrared Search for Extinguished Supernovae in Starburst Galaxies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grossan, B.; Spillar, E.; Tripp, R.
1999-08-01
IR and radio-band observations of heavily extinguished regions in starburst galaxies suggest a high supernova (SN) rate associated with such regions. Optically measured SN rates may therefore underestimate the total SN rate by factors of up to 10, as a result of the very high extinction ({ital A}{sub {ital B}}thinsp{approximately}thinsp10{endash}20 mag) to core-collapse SNe in starburst regions. The IR/radio SN rates come from a variety of indirect means, however, which suffer from model dependence and other problems. We describe a direct measurement of the SN rate from a regular patrol of starburst galaxies done with {ital K}{prime}-band imaging to minimizemore » the effects of extinction. A collection of {ital K}{prime}-band measurements of core-collapse SNe near maximum light is presented. Such measurements (excluding 1987A) are not well reported in the literature. Results of a preliminary {ital K}{prime}-band search, using the MIRC camera at the Wyoming Infrared Observatory and an improved search strategy using the new ORCA optics, are described. A monthly patrol of a sample of {ital IRAS} bright (mostly starburst) galaxies within 25 Mpc should yield 1{endash}6 SNe yr{sup {minus}1}, corresponding to the range of estimated SN rates. Our initial MIRC search with low resolution (2&arcsec;2 pixels) failed to find extinguished SNe in the {ital IRAS} galaxies, limiting the SN rate outside the nucleus (at greater than 15{double_prime} radius) to less than 3.8 far-IR SN rate units (SNe per century per 10{sup 10} {ital L}{sub {circle_dot}} measured at 60 and 100 {mu}m, or FIRSRU) at 90{percent} confidence. The MIRC camera had insufficient resolution to search nuclear starburst regions, where starburst and SN activity is concentrated; therefore, we were unable to rigorously test the hypothesis of high SN rates in heavily obscured star-forming regions. We conclude that high-resolution nuclear SN searches in starburst galaxies with small fields are more productive than low-resolution, large-field searches, even for our sample of large (often several arcminutes) galaxies. With our ORCA high-resolution optics, we could limit the total SN rate to less than 1.3 FIRSRU at 90{percent} confidence in 3 years of observations, lower than most estimates. {copyright} {ital {copyright} 1999.} {ital The American Astronomical Society}« less
Effect of Plate Hardening Behavior on the Deformation of Stainless Steel Metal Bellows
NASA Astrophysics Data System (ADS)
Hao, Zengliang; Luo, Shuyi; Zhao, He; Zhang, Chunxiang; Luo, Junting
2017-11-01
Tensile tests of original plate samples from three types of stainless steel metal bellows were performed at room temperature. The constitutive equations for the three hardening curves were obtained and fitted. The analysis results of the microstructure and fracture morphology of the tensile specimens show that the grain size of the plate with a high logarithmic-exponential hardening rate is uneven and the dimple of the shear fracture is elongated into an ellipse. By contrast, the grain size of the plate with a relatively low linear hardening rate is even and the dimple of the fracture is uniformly equiaxial. Finite element simulations of the hydraulic bulging and repeated limit bending deformation of the metal bellows of the three types of materials were also conducted. The repeated limit bending deformation process was tested experimentally. Although the effect of the hardening exponent on the residual stress of the metal bellows after hydraulic bulging is minimal, this exponent considerably influences the repeated limit bending deformation of the metal bellows after subsequent use. The trough hardening phenomenon is serious in the repeated limit bending process. Moreover, when the hardening exponent of the original plate is high, the resistance to bending fracture at the trough area is poor.
Najotra, Dipender Kaur; Malhotra, Aneeta Singh; Slathia, Poonam; Raina, Shivani; Dhar, Ashok
2017-01-01
Introduction: Microbiological contamination of air and environment in the operation theaters (OTs) are major risk factor for surgical site and other hospital-associated infections. Objectives: The aim was to identify bacterial colonization of surfaces and equipment and to determine the microbial contamination of air in the OTs of a tertiary care hospital. Materials and Methods: Five years (January 2010–December 2014) retrospective analysis of the data obtained from routine microbiological surveillance of the five OTs of the hospital was done. Surface samples were taken with wet swabs from different sites and equipment. Bacterial species were isolated and identified by conventional methods. Air quality surveillance of OTs was done by settle plate method. Results: A total of 4387 samples were collected from surfaces and articles of various OTs. Out of these only 195 (4.4%), samples showed bacterial growth and yielded 210 isolates. The predominant species isolated was Bacillus with 184 (87.6%) isolates followed by coagulase-negative Staphylococcus 17 (8.1%), Staphylococcus aureus 6 (2.9%), and Enteroccoccus spp. 3 (1.4%). Analysis of the OT air samples showed least colony forming unit (cfu) rate of air (27 cfu/m3) in ophthalmology OT and highest rate of 133 cfu/m3 in general surgery OT. Conclusion: The study shows that OTs of our hospital showed a very low bacterial contamination rate on surface swabbing and a cfu count per m3 of air well within permissible limits. PMID:28904915
Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young; Koo, Sun Hoe
2012-01-01
Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. The lower detection limits ranged from 10(1) copies/µL to 5×10(1) copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens.
Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young
2012-01-01
Background Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Methods Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. Results The lower detection limits ranged from 101 copies/µL to 5×101 copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. Conclusions The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens. PMID:22259778
Zhang, Qingteng; Dufresne, Eric M.; Grybos, Pawel; ...
2016-04-19
Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Qingteng; Dufresne, Eric M.; Grybos, Pawel
Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.
Zhang, Qingteng; Dufresne, Eric M; Grybos, Pawel; Kmon, Piotr; Maj, Piotr; Narayanan, Suresh; Deptuch, Grzegorz W; Szczygiel, Robert; Sandy, Alec
2016-05-01
Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. The potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.
Denawaka, Chamila J; Fowlis, Ian A; Dean, John R
2014-04-18
An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were identified and quantified: ammonia, dimethyl disulphide, dimethyl trisulphide and butyric acid. A link was identified between the presence of high ammonia and dimethyl disulphide concentrations and a high malodour odour grading, that is, ≥ 6. Statistical analysis did not find any correlation between the occurrence of dimethyl disulphide and participant gender. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud
2018-01-01
For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.
Molognoni, Luciano; de Sá Ploêncio, Leandro Antunes; Valese, Andressa Camargo; De Dea Lindner, Juliano; Daguer, Heitor
2016-01-15
In this work, a simplified extraction and short time of analysis method for the simultaneous determination of natamycin, nisin and sorbic acid in cheeses and cream by reverse phase liquid chromatography-electrospray-tandem mass spectrometry was developed. Full validation was performed according to the Commission Decision 2002/657/EC criteria and method applicability was checked on several samples, aiming to inspect their compliance with regulatory limits. The method was linear in the concentration ranges of 0-10mg kg(-1) (natamycin), 0-25mg kg(-1) (nisin) and 0 20mg kg(-1) (sorbic acid). Samples of the three most consumed types of cheese (fresh, pasta filata and ripened) in Brazil and cream (ultra high temperature and pasteurized, 20-30% fat content) were assessed. A surprising rate of non-compliance was observed, especially among ripened grated cheeses, since 80% of samples were above the maximum limit for sorbic acid with an average concentration of 2766.3±10.8mg kg(-1). Moreover, a major non-compliance for the cream samples was observed. The proposed method can be applied as an efficient tool for the inspection of preservatives in cheeses and cream. Copyright © 2015 Elsevier B.V. All rights reserved.
Liu, Huihui; Han, Dianfeng; Huang, Hui; Xu, Yingjiang; Gong, Xianghong
2018-01-01
This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ), in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20 μg/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD) of all the three metabolites ranged from 0.21 to 0.48 μg/kg, while the limit of quantification (LOQ) ranged from 0.79 to 1.59 μg/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian. PMID:29805832
Liu, Huihui; Ren, Chuanbo; Han, Dianfeng; Huang, Hui; Zou, Rongjie; Zhang, Huawei; Xu, Yingjiang; Gong, Xianghong; Zhang, Xiuzhen; Li, Yanshen
2018-01-01
This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ), in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20 μ g/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD) of all the three metabolites ranged from 0.21 to 0.48 μ g/kg, while the limit of quantification (LOQ) ranged from 0.79 to 1.59 μ g/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian.
Arenas, Alicia; Giorgi, Gabriele; Montani, Francesco; Mancuso, Serena; Perez, Javier Fiz; Mucci, Nicola; Arcangeli, Giulio
2015-01-01
Purpose - The purpose of this study is to examine the prevalence rate of workplace bullying in a sample of Italian and Spanish employees, and its differential consequences on employees' job satisfaction and psychological well-being. The effects of workplace bullying on job satisfaction and psychological well-being were explored taking into account a contextualized approach. Design/Methodology/approach - Cross-sectional study was adopted, in which a sample of 1,151 employees in Italy and 705 in Spain completed a questionnaire. We hypothesized that the relationship between exposure to bullying behaviors and psychological well-being is mediated by job satisfaction, and that this simple mediation model is moderated by the country (moderated mediation). Findings - Results suggest that no particular differences exist in bullying prevalence among Spanish and Italian employees. However, we found scientific confirmation of our hypothesized moderated mediation model. Research limitations/implications - Despite the limitations of the sample studied, findings capture contextual differences in the bullying phenomenon, which may have several implications for further research in this domain, as well as for designing interventions to deal with workplace bullying. Originality/value - Although this study explores bullying in different cultural contexts without investigating specific cultural values, it establishes the roots to assess workplace bullying from a contextualized perspective.
Review of sampling hard-to-reach and hidden populations for HIV surveillance.
Magnani, Robert; Sabin, Keith; Saidel, Tobi; Heckathorn, Douglas
2005-05-01
Adequate surveillance of hard-to-reach and 'hidden' subpopulations is crucial to containing the HIV epidemic in low prevalence settings and in slowing the rate of transmission in high prevalence settings. For a variety of reasons, however, conventional facility and survey-based surveillance data collection strategies are ineffective for a number of key subpopulations, particularly those whose behaviors are illegal or illicit. This paper critically reviews alternative sampling strategies for undertaking behavioral or biological surveillance surveys of such groups. Non-probability sampling approaches such as facility-based sentinel surveillance and snowball sampling are the simplest to carry out, but are subject to a high risk of sampling/selection bias. Most of the probability sampling methods considered are limited in that they are adequate only under certain circumstances and for some groups. One relatively new method, respondent-driven sampling, an adaptation of chain-referral sampling, appears to be the most promising for general applications. However, as its applicability to HIV surveillance in resource-poor settings has yet to be established, further field trials are needed before a firm conclusion can be reached.
Giesinger, Johannes M; Aaronson, Neil K; Arraras, Juan I; Efficace, Fabio; Groenvold, Mogens; Kieffer, Jacobien M; Loth, Fanny L; Petersen, Morten Aa; Ramage, John; Tomaszewski, Krzysztof A; Young, Teresa; Holzner, Bernhard
2018-02-01
In this study, we investigated what makes a symptom or functional impairment clinically important, that is, relevant for a patient to discuss with a health care professional (HCP). This is the first part of a European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group project focusing on the development of thresholds for clinical importance for the EORTC QLQ-C30 questionnaire and its corresponding computer-adaptive version. We conducted interviews with cancer patients and HCPs in 6 European countries. Participants were asked to name aspects of a symptom or problem that make it clinically important and to provide importance ratings for a predefined set of aspects (eg, need for help and limitations of daily functioning). We conducted interviews with 83 cancer patients (mean age, 60.3 y; 50.6% men) and 67 HCPs. Participants related clinical importance to limitations of everyday life (patients, 65.1%; HCPs, 77.6%), the emotional impact of a symptom/problem (patients, 53.0%; HCPs, 64.2%), and duration/frequency (patients, 51.8%; HCPs, 49.3%). In the patient sample, importance ratings were highest for worries by partner or family, limitations in everyday life, and need for help from the medical staff. Health care professionals rated limitations in everyday life and need for help from the medical staff to be most important. Limitations in everyday life, need for (medical) help, and emotional impact on the patient or family/partner were found to be relevant aspects of clinical importance. Based on these findings, we will define anchor items for the development of thresholds for clinical importance for the EORTC measures in a Europe-wide field study. Copyright © 2017 John Wiley & Sons, Ltd.
Griffin, Dale W.; Gonzalez, C.; Teigell, N.; Petrosky, T.; Northup, D.E.; Lyles, M.
2011-01-01
The influence of sample-collection-time on the recovery of culturable airborne microorganisms using a low-flow-rate membrane-filtration unit and a high-flow-rate liquid impinger were investigated. Differences in recoveries were investigated in four different atmospheric environments, one mid-oceanic at an altitude of ~10.0 m, one on a mountain top at an altitude of ~3,000.0 m, one at ~1.0 m altitude in Tallahassee, Florida, and one at ~1.0 m above ground in a subterranean-cave. Regarding use of membrane filtration, a common trend was observed: the shorter the collection period, the higher the recovery of culturable bacteria and fungi. These data also demonstrated that lower culturable counts were common in the more remote mid-oceanic and mountain-top atmospheric environments with bacteria, fungi, and total numbers averaging (by sample time or method categories) <3.0 colony-forming units (CFU) m -3. At the Florida and subterranean sites, the lowest average count noted was 3.5 bacteria CFU m-3, and the highest averaged 140.4 total CFU m-3. When atmospheric temperature allowed use, the high-volume liquid impinger utilized in this study resulted in much higher recoveries, as much as 10?? greater in a number of the categories (bacterial, fungal, and total CFU). Together, these data illustrated that (1) the high-volume liquid impinger is clearly superior to membrane filtration for aeromicrobiology studies if start-up costs are not an issue and temperature permits use; (2) although membrane filtration is more cost friendly and has a 'typically' wider operational range, its limits include loss of cell viability with increased sample time and issues with effectively extracting nucleic acids for community-based analyses; (3) the ability to recover culturable microorganisms is limited in 'extreme' atmospheric environments and thus the use of a 'limited' methodology in these environments must be taken into account; and (4) the atmosphere culls, i.e., everything is not everywhere. ?? 2010 US Government.