Sample records for limiting dilution analysis

  1. Avian plasma chemistry analysis using diluted samples.

    PubMed

    Waldoch, Jennifer; Wack, Raymund; Christopher, Mary

    2009-12-01

    Clinical chemistry tests are essential for the diagnosis and monitoring of disease in birds. The small volume of blood that can be obtained from many avian species limits the use of routine in-house chemistry analyzers. The aim of this study was to examine the accuracy and precision of avian plasma chemistry values obtained by use of a benchtop analyzer in samples diluted with sterile water, as compared with undiluted samples. Whole blood samples were collected from 13 clinically healthy thick-billed parrots (Rhynchopsitta pachyrhyncha). The samples were placed in lithium heparin tubes and centrifuged and the plasma decanted. One aliquot was analyzed immediately using a VetScan benchtop analyzer with an avian-reptile-specific rotor that included 12 analytes. The remainder of the plasma was divided into two aliquots and stored at -80 degrees C until analysis. One of these aliquots was diluted 1:1, 1:1.5, 1:2, and 1:2.5 with sterile water to give final dilutions of 1:2, 1:2.5, 1:3, and 1:3.5, respectively. The other aliquot was pooled with the 12 other samples to create a plasma pool. The undiluted plasma pool and two final dilutions (1:2 and 1:3) of the pooled plasma were analyzed in replicate (n = 20) to determine intra- and interassay imprecision. Each dilution was analyzed using the avian-reptile rotor and the results multiplied by the appropriate dilution factor to obtain the final result. Significant differences were observed in clinical chemistry results obtained from diluted plasma samples for all analytes except aspartate aminotransferase, creatine kinase, and glucose. Uric acid concentration was not significantly different at dilutions of up to 1:3. Bile acids, globulins, and sodium concentrations were below the limit of detection in all diluted samples and were not statistically analyzed. Based on these results, dilution with sterile water is not recommended for biochemical analysis of avian plasma using the VetScan benchtop analyzer.

  2. A roadmap to defining the clinical reportable ranges of chemistry analytes: Increasing automation efficiency and decreasing manual dilutions.

    PubMed

    Lo, Sheng-Ying; Baird, Geoffrey S; Greene, Dina N

    2015-12-07

    Proper utilization of resources is an important operational objective for clinical laboratories. To reduce unnecessary manual interventions on automated instruments, we conducted a workflow analysis that optimized dilution parameters and reporting of abnormally high chemistry results for the Beckman AU series of chemistry analyzers while maintaining clinically acceptable reportable ranges. Workflow analysis for the Beckman AU680/5812 and DxC800 chemistry analyzers was performed using historical data. Clinical reportable ranges for 53 chemistry analytes were evaluated. Optimized dilution parameters and upper limit of reportable ranges for the AU680/5812 instruments were derived and validated to meet these reportable ranges. The number of specimens that required manual dilutions before and after optimization was determined for both the AU680/5812 and DxC800, with the DxC800 serving as the reference instrument. Retrospective data analysis revealed that 7700 specimens required manual dilutions on the DxC over a 2-y period. Using our optimized AU-specific dilution and reporting parameters, the data-driven simulation analysis showed a 61% reduction in manual dilutions. For the specimens that required manual dilutions on the AU680/5812, we developed standardized dilution procedures to further streamline workflow. We provide a data-driven, practical outline for clinical laboratories to efficiently optimize their use of automated chemistry analyzers. The outcomes can be used to assist laboratories wishing to improve their existing procedures or to facilitate transitioning into a new line of instrumentation, regardless of the instrument model or manufacturer. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Pushing quantitation limits in micro UHPLC-MS/MS analysis of steroid hormones by sample dilution using high volume injection.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Szabó, Pál Tamás

    2016-09-10

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LoQ). Micro UHPLC coupling with sensitive tandem mass spectrometry provides state of the art solutions for such analytical problems. Decreased column volume in micro LC limits the injectable sample volume. However, if analyte concentration is extremely low, it might be necessary to inject high sample volumes. This is particularly critical for strong sample solvents and weakly retained analytes, which are often the case when preparing biological samples (protein precipitation, sample extraction, etc.). In that case, high injection volumes may cause band broadening, peak distortion or even elution in dead volume. In this study, we evaluated possibilities of high volume injection onto microbore RP-LC columns, when sample solvent is diluted. The presented micro RP-LC-MS/MS method was optimized for the analysis of steroid hormones from human plasma after protein precipitation with organic solvents. A proper sample dilution procedure helps to increase the injection volume without compromising peak shapes. Finally, due to increased injection volume, the limit of quantitation can be decreased by a factor of 2-5, depending on the analytes and the experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Diel variation of the cellular carbon to nitrogen ratio of Chlorella autotrophica (Chlorophyta) growing in phosphorus- and nitrogen-limited continuous cultures.

    PubMed

    Ng, Wai Ho Albert; Liu, Hongbin

    2015-02-01

    We investigated the relationship between daily growth rates and diel variation of carbon (C) metabolism and C to nitrogen (N) ratio under P- and N-limitation in the green algae Chlorella autotrophica. To do this, continuous cultures of C. autotrophica were maintained in a cyclostat culture system under 14:10 light:dark cycle over a series of P- and N-limited growth rates. Cell abundance, together with cell size, as reflected by side scatter signal from flow cytometric analysis demonstrated a synchronized diel pattern with cell division occurring at night. Under either type of nutrient limitation, the cellular C:N ratio increased through the light period and decreased through the dark period over all growth rates, indicating a higher diel variation of C metabolism than that of N. Daily average cellular C:N ratios were higher at lower dilution rates under both types of nutrient limitation but cell enlargement was only observed at lower dilution rates under P-limitation. Carbon specific growth rates during the dark period positively correlated with cellular daily growth rates (dilution rates), with net loss of C during night at the lowest growth rates under N-limitation. Under P-limitation, dark C specific growth rates were close to zero at low dilution rates but also exhibited an increasing trend at high dilution rates. In general, diel variations of cellular C:N were low when dark C specific growth rates were high. This result indicated that the fast growing cells performed dark C assimilation at high rates, hence diminished the uncoupling of C and N metabolism at night. © 2014 Phycological Society of America.

  5. Comparison of body composition assessment methods in pediatric intestinal failure.

    PubMed

    Mehta, Nilesh M; Raphael, Bram; Guteirrez, Ivan M; Quinn, Nicolle; Mitchell, Paul D; Litman, Heather J; Jaksic, Tom; Duggan, Christopher P

    2014-07-01

    The aim of the study was to examine the agreement of multifrequency bioelectric impedance analysis (BIA) and anthropometry with reference methods for body composition assessment in children with intestinal failure (IF). We conducted a prospective pilot study in children 14 years or younger with IF resulting from either short bowel syndrome or motility disorders. Bland-Altman analysis was used to examine the agreement between BIA and deuterium dilution in measuring total body water (TBW) and lean body mass (LBM), and between BIA and dual-energy x-ray absorptiometry (DXA) techniques in measuring LBM and fat mass (FM). FM and percent body fat (%BF) measurements by BIA and anthropometry were also compared in relation to those measured by deuterium dilution. Fifteen children with IF, median (interquartile range) age 7.2 (5.0, 10.0) years, and 10 (67%) boys, were studied. BIA and deuterium dilution were in good agreement with a mean bias (limits of agreement) of 0.9 (-3.2 to 5.0) for TBW (L) and 0.1 (-5.4 to 5.6) for LBM (kg) measurements. The mean bias (limits) for FM (kg) and %BF measurements were 0.4 (-3.8 to 4.6) kg and 1.7 (-16.9 to 20.3)%, respectively. The limits of agreement were within 1 standard deviation of the mean bias in 12 of 14 (86%) subjects for TBW and LBM, and in 11 of 14 (79%) for FM and %BF measurements. Mean bias (limits) for LBM (kg) and FM (kg) between BIA and DXA were 1.6 (-3.0 to 6.3) kg and -0.1 (-3.2 to 3.1) kg, respectively. Mean bias (limits) for FM (kg) and %BF between anthropometry and deuterium dilution were 0.2 (-4.2 to 4.6) and -0.2 (-19.5 to 19.1), respectively. The limits of agreement were within 1 standard deviation of the mean bias in 10 of 14 (71%) subjects. In children with IF, TBW and LBM measurements by multifrequency BIA method were in agreement with isotope dilution and DXA methods, with small mean bias and clinically acceptable limits of agreement. In comparison with deuterium dilution, BIA was comparable to anthropometry for FM and %BF assessments with small mean bias, but the limits of agreement were large. BIA is a reliable method for TBW and LBM assessments in population studies; however, its reliability in individual patients, especially for FM assessments, cannot be guaranteed.

  6. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    PubMed

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the presence of shunts.

  7. Beating the odds: The poisson distribution of all input cells during limiting dilution grossly underestimates whether a cell line is clonally-derived or not.

    PubMed

    Zhou, Yizhou; Shaw, David; Lam, Cynthia; Tsukuda, Joni; Yim, Mandy; Tang, Danming; Louie, Salina; Laird, Michael W; Snedecor, Brad; Misaghi, Shahram

    2017-09-23

    Establishing that a cell line was derived from a single cell progenitor and defined as clonally-derived for the production of clinical and commercial therapeutic protein drugs has been the subject of increased emphasis in cell line development (CLD). Several regulatory agencies have expressed that the prospective probability of clonality for CHO cell lines is assumed to follow the Poisson distribution based on the input cell count. The probability of obtaining monoclonal progenitors based on the Poisson distribution of all cells suggests that one round of limiting dilution may not be sufficient to assure the resulting cell lines are clonally-derived. We experimentally analyzed clonal derivatives originating from single cell cloning (SCC) via one round of limiting dilution, following our standard legacy cell line development practice. Two cell populations with stably integrated DNA spacers were mixed and subjected to SCC via limiting dilution. Cells were cultured in the presence of selection agent, screened, and ranked based on product titer. Post-SCC, the growing cell lines were screened by PCR analysis for the presence of identifying spacers. We observed that the percentage of nonclonal populations was below 9%, which is considerably lower than the determined probability based on the Poisson distribution of all cells. These results were further confirmed using fluorescence imaging of clonal derivatives originating from SCC via limiting dilution of mixed cell populations expressing GFP or RFP. Our results demonstrate that in the presence of selection agent, the Poisson distribution of all cells clearly underestimates the probability of obtaining clonally-derived cell lines. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 2017. © 2017 American Institute of Chemical Engineers.

  8. Cloning by limiting dilution: an improved estimate that an interesting culture is monoclonal.

    PubMed Central

    Staszewski, R.

    1984-01-01

    An interesting culture obtained by limiting dilution is less likely to be monoclonal than a random viable culture. Current practice using limiting dilution to establish monoclonal lines of interesting recombinant DNA or hybridoma-derived organisms overestimates the probability that promising cultures are monoclonal, resulting in inadequate dilutions, with the need for additional subcloning and the avoidable loss (avoidable instability) of interesting lines by overgrowth with uninteresting varieties. PMID:6537695

  9. Determination of the Absolute Number of Cytokine mRNA Molecules within Individual Activated Human T Cells

    NASA Technical Reports Server (NTRS)

    Karr, Laurel J.; Marshall, Gwen; Hockett, Richard D.; Bucy, R. Pat; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    A primary function of activated T cells is the expression and subsequent secretion of cytokines, which orchestrate the differentiation of other lymphocytes, modulate antigen presenting cell activity, and alter vascular endothelium to mediate an immune response. Since many features of immune regulation probably result from modest alterations of endogenous rates of multiple interacting processes, quantitative analysis of the frequency and specific activity of individual T cells is critically important. Using a coordinated set of quantitative methods, the absolute number of molecules of several key cytokine mRNA species in individual T cells has been determined. The frequency of human blood T cells activated in vitro by mitogens and recall protein antigens was determined by intracellular cytokine protein staining, in situ hybridization for cytokine mRNA, and by limiting dilution analysis for cytokine mRNA+ cells. The absolute number of mRNA molecules was simultaneously determined in both homogenates of the entire population of cells and in individual cells obtained by limiting dilution, using a quantitative, competitive RT-PCR assay. The absolute numbers of mRNA molecules in a population of cells divided by the frequency of individual positive cells, yielded essentially the same number of mRNA molecules per cell as direct analysis of individual cells by limiting dilution analysis. Mean numbers of mRNA per positive cell from both mitogen and antigen activated T cells, using these stimulation conditions, were 6000 for IL-2, 6300 for IFN-gamma, and 1600 for IL-4.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevik, James; Wallner, Thomas; Pamminger, Michael

    The efficiency improvement and emissions reduction potential of lean and exhaust gas recirculation (EGR)-dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nanosecond pulses and its performance compared to a conventional transistorized coilmore » ignition (TCI) system operated on an automotive, gasoline direct-injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar indicated mean effective pressure (IMEP), where dilution tolerance is particularly critical to improving efficiency and emission performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ = 1.55 to 1.7) with the low-energy transient plasma ignition system.« less

  11. CORMIX: AN EXPERT SYSTEM FOR MIXING ZONE ANALYSIS

    EPA Science Inventory

    United States water quality policy includes the concept of a fixing zone, a limited area where initial dilution of a discharge occurs. urrent practice in mixing zone analysis is plagued by a number of problems--mixing zone definitions vary widely, there is a diversity of discharg...

  12. Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.

    PubMed

    Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W

    2015-11-01

    In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. The long-time dynamics of two hydrodynamically-coupled swimming cells.

    PubMed

    Michelin, Sébastien; Lauga, Eric

    2010-05-01

    Swimming microorganisms such as bacteria or spermatozoa are typically found in dense suspensions, and exhibit collective modes of locomotion qualitatively different from that displayed by isolated cells. In the dilute limit where fluid-mediated interactions can be treated rigorously, the long-time hydrodynamics of a collection of cells result from interactions with many other cells, and as such typically eludes an analytical approach. Here, we consider the only case where such problem can be treated rigorously analytically, namely when the cells have spatially confined trajectories, such as the spermatozoa of some marine invertebrates. We consider two spherical cells swimming, when isolated, with arbitrary circular trajectories, and derive the long-time kinematics of their relative locomotion. We show that in the dilute limit where the cells are much further away than their size, and the size of their circular motion, a separation of time scale occurs between a fast (intrinsic) swimming time, and a slow time where hydrodynamic interactions lead to change in the relative position and orientation of the swimmers. We perform a multiple-scale analysis and derive the effective dynamical system--of dimension two--describing the long-time behavior of the pair of cells. We show that the system displays one type of equilibrium, and two types of rotational equilibrium, all of which are found to be unstable. A detailed mathematical analysis of the dynamical systems further allows us to show that only two cell-cell behaviors are possible in the limit of t-->infinity, either the cells are attracted to each other (possibly monotonically), or they are repelled (possibly monotonically as well), which we confirm with numerical computations. Our analysis shows therefore that, even in the dilute limit, hydrodynamic interactions lead to new modes of cell-cell locomotion.

  14. Competition explains limited attention and perceptual resources: implications for perceptual load and dilution theories.

    PubMed

    Scalf, Paige E; Torralbo, Ana; Tapia, Evelina; Beck, Diane M

    2013-01-01

    Both perceptual load theory and dilution theory purport to explain when and why task-irrelevant information, or so-called distractors are processed. Central to both explanations is the notion of limited resources, although the theories differ in the precise way in which those limitations affect distractor processing. We have recently proposed a neurally plausible explanation of limited resources in which neural competition among stimuli hinders their representation in the brain. This view of limited capacity can also explain distractor processing, whereby the competitive interactions and bias imposed to resolve the competition determine the extent to which a distractor is processed. This idea is compatible with aspects of both perceptual load and dilution models of distractor processing, but also serves to highlight their differences. Here we review the evidence in favor of a biased competition view of limited resources and relate these ideas to both classic perceptual load theory and dilution theory.

  15. Physiological, biomass elemental composition and proteomic analyses of Escherichia coli ammonium-limited chemostat growth, and comparison with iron- and glucose-limited chemostat growth

    PubMed Central

    Folsom, James Patrick

    2015-01-01

    Escherichia coli physiological, biomass elemental composition and proteome acclimations to ammonium-limited chemostat growth were measured at four levels of nutrient scarcity controlled via chemostat dilution rate. These data were compared with published iron- and glucose-limited growth data collected from the same strain and at the same dilution rates to quantify general and nutrient-specific responses. Severe nutrient scarcity resulted in an overflow metabolism with differing organic byproduct profiles based on limiting nutrient and dilution rate. Ammonium-limited cultures secreted up to 35  % of the metabolized glucose carbon as organic byproducts with acetate representing the largest fraction; in comparison, iron-limited cultures secreted up to 70  % of the metabolized glucose carbon as lactate, and glucose-limited cultures secreted up to 4  % of the metabolized glucose carbon as formate. Biomass elemental composition differed with nutrient limitation; biomass from ammonium-limited cultures had a lower nitrogen content than biomass from either iron- or glucose-limited cultures. Proteomic analysis of central metabolism enzymes revealed that ammonium- and iron-limited cultures had a lower abundance of key tricarboxylic acid (TCA) cycle enzymes and higher abundance of key glycolysis enzymes compared with glucose-limited cultures. The overall results are largely consistent with cellular economics concepts, including metabolic tradeoff theory where the limiting nutrient is invested into essential pathways such as glycolysis instead of higher ATP-yielding, but non-essential, pathways such as the TCA cycle. The data provide a detailed insight into ecologically competitive metabolic strategies selected by evolution, templates for controlling metabolism for bioprocesses and a comprehensive dataset for validating in silico representations of metabolism. PMID:26018546

  16. Hybridizing pines with diluted pollen

    Treesearch

    Robert Z. Callaham

    1967-01-01

    Diluted pollens would have many uses by the tree breeder. Dilutions would be particularly advantageous in making many controlled pollinations with a limited amount of pollen. They also would be useful in artificial mass pollinations of orchards or single trees. Diluted pollens might help overcome troublesome genetic barriers to crossing. Feasibility o,f using diluted...

  17. On the Wigner law in dilute random matrices

    NASA Astrophysics Data System (ADS)

    Khorunzhy, A.; Rodgers, G. J.

    1998-12-01

    We consider ensembles of N × N symmetric matrices whose entries are weakly dependent random variables. We show that random dilution can change the limiting eigenvalue distribution of such matrices. We prove that under general and natural conditions the normalised eigenvalue counting function coincides with the semicircle (Wigner) distribution in the limit N → ∞. This can be explained by the observation that dilution (or more generally, random modulation) eliminates the weak dependence (or correlations) between random matrix entries. It also supports our earlier conjecture that the Wigner distribution is stable to random dilution and modulation.

  18. Flexible nano- and microliter injections on a single liquid chromatography-mass spectrometry system: Minimizing sample preparation and maximizing linear dynamic range.

    PubMed

    Lubin, Arnaud; Sheng, Sheng; Cabooter, Deirdre; Augustijns, Patrick; Cuyckens, Filip

    2017-11-17

    Lack of knowledge on the expected concentration range or insufficient linear dynamic range of the analytical method applied are common challenges for the analytical scientist. Samples that are above the upper limit of quantification are typically diluted and reanalyzed. The analysis of undiluted highly concentrated samples can cause contamination of the system, while the dilution step is time consuming and as the case for any sample preparation step, also potentially leads to precipitation, adsorption or degradation of the analytes. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Assessment of body fat in the pony: part II. Validation of the deuterium oxide dilution technique for the measurement of body fat.

    PubMed

    Dugdale, A H A; Curtis, G C; Milne, E; Harris, P A; Argo, C Mc

    2011-09-01

    Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids. © 2011 EVJ Ltd.

  20. Extended Le Chatelier's formula for carbon dioxide dilution effect on flammability limits.

    PubMed

    Kondo, Shigeo; Takizawa, Kenji; Takahashi, Akifumi; Tokuhashi, Kazuaki

    2006-11-02

    Carbon dioxide dilution effect on the flammability limits was measured for various flammable gases. The obtained values were analyzed using the extended Le Chatelier's formula developed in a previous study. As a result, it has been found that the flammability limits of methane, propane, propylene, methyl formate, and 1,1-difluoroethane are adequately explained by the extended Le Chatelier's formula using a common set of parameter values. Ethylene, dimethyl ether, and ammonia behave differently from these compounds. The present result is very consistent with what was obtained in the case of nitrogen dilution.

  1. EXPERT SYSTEMS FOR MIXING-ZONE ANALYSIS AND DESIGN OF POLLUTANT DISCHARGES

    EPA Science Inventory

    Water-quality policy in the United States includes the concept of a mixing zone, a limited area or volume of water where initial dilution of an aqueous pollutant discharge occurs. iven a myriad of possible discharge configurations, ambient environments, and mixing zone definition...

  2. Constraints on dilution from a narrow attentional zoom reveal how spatial and color cues direct selection.

    PubMed

    Chen, Zhe; Cave, Kyle R

    2014-08-01

    Distractor interference is subject to dilution from other nontarget elements, and the level of dilution is affected by attention. This study explores the nature of dilution when the location and color of the target is known in advance. Experiments 1 and 2 show that attention is effectively limited to the precued region, so that it is the nontarget letters appearing at the cued locations that are responsible for most of the dilution, and not those appearing at the uncued locations. Furthermore, this dilution occurs relatively early in processing. Experiment 3 demonstrates that top-down attentional control can prevent dilution, because foreknowledge of the target color leads to quick attention shifts. Experiment 4 illustrates bottom-up attentional control in preventing dilution when the distractor is a color singleton that is segregated from the diluting nontargets. The results show that dilution is modulated by both top-down and bottom-up factors, that it can occur even when attention is restricted to a relatively small region, and that it occurs early in processing, but not so early that it avoids the effects of attention. They provide new challenges for earlier accounts suggesting that dilution is widespread and unfettered by attention. Likewise, some parts of the results are difficult to reconcile with the alternative perceptual load theory, but they do support a form of dilution that is limited by attentional boundaries. Because of that link to attention, dilution is a useful tool for measuring how attention is guided by information about target location and color. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Helicity moduli of three-dimensional dilute XY models

    NASA Astrophysics Data System (ADS)

    Garg, Anupam; Pandit, Rahul; Solla, Sara A.; Ebner, C.

    1984-07-01

    The helicity moduli of various dilute, classical XY models on three-dimensional lattices are studied with a view to understanding some aspects of the superfluidity of 4He in Vycor glass. A spinwave calculation is used to obtain the low-temperature helicity modulus of a regularly-diluted XY model. A similar calculation is performed for the randomly bond-diluted and site-diluted XY models in the limit of low dilution. A Monte Carlo simulation is used to obtain the helicity modulus of the randomly bond-diluted XY model over a wide range of temperature and dilution. It is found that the randomly diluted models do agree and the regularly diluted model does not agree with certain experimentally found features of the variation in superfluid fraction with coverage of 4He in Vycor glass.

  4. A Contactless Capacitance Detection System for Microchip Capillary Electrophoresis

    NASA Astrophysics Data System (ADS)

    Wu, Peter

    2008-05-01

    The design, construction and operation of a simple, inexpensive and compact high voltage power supply for use in conjunction with a simple cross, capillary electrophoresis microchip is presented. The detection system utilizes a single high voltage power supply (15 kV), a voltage divider network for obtaining the required voltages for enabling a gated injection valve, and two high voltage relays for switching between the open and closed gate sequences of the injection. The system is used to determine sodium monofluoroacetate (MFA) concentration in diluted fruit juices and tap water. A separation buffer consisting of 20 mM citric acid and histidine at pH 3.5 enabled the detection of the anion in diluted apple juice, cranberry juice, and orange juice without lengthy sample pretreatments. Limit of detection in diluted juices and tap water were determined to be 125, 167, 138, and 173 mg/L for tap water, apple juice, cranberry juice, and orange juice, respectively, based upon an S/N of 3:1. The total analysis time for detecting the MFA anion in fruit juices was less than 5 min, which represents a considerable reduction in analysis time compared to other analytical methods currently used in food analysis.

  5. Fertility Limitation and Child Schooling in Ouagadougou: Selective Fertility or Resource Dilution?

    PubMed

    Bougma, Moussa; LeGrand, Thomas K; Kobiané, Jean-François

    2015-06-01

    Using original data collected in Ouagadougou, Burkina Faso, this study investigates evidence for the competing theories that fertility reductions increase children's education through either the quantity-quality tradeoff (intentionally choosing smaller families to make greater investments in education and other indicators of child quality) or resource dilution (having more children reduces resources available per child, regardless of intentionality of family size). The results provide evidence for both hypotheses: children having four or fewer siblings were significantly more likely to be enrolled in school if their mothers had intentionally stopped childbearing relative to those whose mothers wanted more children but whose childbearing was limited by subfecundity. The difference between intentional and unintentional family limitation was not significant for parities greater than five. In addition, the relationship between number of siblings and their schooling is negative, regardless of the intentionality of family-size limitation, but the strength of this negative relationship is approximately twice as high among children whose mothers intentionally limited fertility (reflecting both selection and dilution effects) than among children whose mothers were subfecund (reflecting the pure dilution effect). © 2015 The Population Council, Inc.

  6. Congener-specific determination of ultratrace levels of chlorinated and brominated polycyclic aromatic hydrocarbons in atmosphere and industrial stack gas by isotopic dilution gas chromatography/high resolution mass spectrometry method.

    PubMed

    Jin, Rong; Liu, Guorui; Zheng, Minghui; Fiedler, Heidelore; Jiang, Xiaoxu; Yang, Lili; Wu, Xiaolin; Xu, Yang

    2017-08-04

    Isotopic dilution gas chromatography combined with high resolution mass spectrometry (GC/HRMS) has overwhelming advantages with respect to the accuracy of congener-specific ultratrace analysis of complex persistent organic pollutants (POPs) in environmental matrices. However, an isotopic dilution GC/HRMS method for analysis of chlorinated and brominated polycyclic aromatic hydrocarbons (Cl-PAHs and Br-PAHs) using 13 C-labelled congeners as internal standards has not been established. In this study, a method for identification and quantification of 38 congeners of Cl-PAHs and Br-PAHs in atmosphere and stack gas samples from waste incinerators was developed using the isotopic dilution GC/HRMS technique. The instrumental detection limits of the GC/HRMS method ranged from 0.2pg to 1.8pg for Cl-PAH congeners, and 0.7pg to 2.7pg for Br-PAH congeners, which were about three orders of magnitude lower than those of the GC/quadrupole MS method. This new method developed was also the first to enable determination of Cl-PAH and Br-PAH homologs comprising congeners with the same molecular skeleton and chlorine or bromine substitution numbers. Among the detected congeners, seven Cl-PAH congeners and thirteen Br-PAH congeners that were abundant in the atmosphere and stack gases released from waste incinerators were firstly detected in real samples and reported using the established isotopic dilution GC/HRMS method. The developed isotopic dilution GC/HRMS is significant and needed for better studying the environmental behavior and health risk of Cl-PAHs and Br-PAHs. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Premature preterm rupture of the membrane diagnosis in early pregnancy: PAMG-1 and IGFBP-1 detection in amniotic fluid with biochemical tests.

    PubMed

    Doret, Muriel; Cartier, Régine; Miribel, Juliette; Massardier, Jérome; Massoud, Mona; Bordes, Agnès; Moret, Stéphanie; Gaucherand, Pascal

    2013-12-01

    Previable premature rupture of the membranes (pPROM), occurring before 24WG, is associated with a 25% neonatal survival rate. This terrible prognosis may lead to elective pregnancy termination on parents' request. Therefore, certain diagnosis is essential but remains difficult in about 10% of patients. Bed-side biochemical tests developed to help in diagnosis had never been evaluated in early pregnancies. This study aimed to evaluate and compare the in vitro sensitivity, detection limit, reaction time and consistency of AmniSure detecting placental alpha microglobulin-1 (PAMG-1) and actim PROM detecting Insulin Growth Factor Binding Protein-1 (IGFBP-1) in amniotic fluid between 15 and 20weeks of gestation (WG). Samples of amniotic fluid were collected by amniocentesis performed between 15 and 20 completed WG in 55 patients. Dilution series were prepared and both tests were performed twice at each dilution. In vitro sensitivity, detection limit, and reaction time were evaluated and compared in serial dilution. A total of 460 AmniSure and 476 actim PROM tests were performed. Both tests' in vitro sensitivity was 100% at dilution 1:20 and remained up to 90% until dilution 1:80. In vitro sensitivities were not different at any dilution. Detection limit and consistency were similar for both tests at all dilution. Actim PROM reaction time was shorter than AmniSure at all dilutions, except 1:320 (p<0.05). PAMG-1 and IGFBP-1 can be detected in amniotic fluid between 15 and 20 completed WG, using respectively AmniSure and actim PROM. © 2013.

  8. Decorrelation correction for nanoparticle tracking analysis of dilute polydisperse suspensions in bulk flow

    NASA Astrophysics Data System (ADS)

    Hartman, John; Kirby, Brian

    2017-03-01

    Nanoparticle tracking analysis, a multiprobe single particle tracking technique, is a widely used method to quickly determine the concentration and size distribution of colloidal particle suspensions. Many popular tools remove non-Brownian components of particle motion by subtracting the ensemble-average displacement at each time step, which is termed dedrifting. Though critical for accurate size measurements, dedrifting is shown here to introduce significant biasing error and can fundamentally limit the dynamic range of particle size that can be measured for dilute heterogeneous suspensions such as biological extracellular vesicles. We report a more accurate estimate of particle mean-square displacement, which we call decorrelation analysis, that accounts for correlations between individual and ensemble particle motion, which are spuriously introduced by dedrifting. Particle tracking simulation and experimental results show that this approach more accurately determines particle diameters for low-concentration polydisperse suspensions when compared with standard dedrifting techniques.

  9. Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry.

    PubMed

    Kawaguchi, Migaku; Takatsu, Akiko

    2009-08-01

    A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.

  10. The measurement of lung volumes using body plethysmography and helium dilution methods in COPD patients: a correlation and diagnosis analysis.

    PubMed

    Tang, Yongjiang; Zhang, Mingke; Feng, Yulin; Liang, Binmiao

    2016-11-23

    Chronic obstructive pulmonary disease (COPD) is a chronic airway disease characterized by persistent airflow limitation. Moreover, lung hyperinflation evaluated by lung volumes is also the key pathophysiologic process during COPD progression. Nevertheless, there is still no preferred method to evaluate lung volumes. For this study, we recruited 170 patients with stable COPD to assess lung volumes stratified by airflow limitation severity. Lung volumes including residual volume (RV) and total lung capacity (TLC) were determined by both body plethysmography and helium dilution methods. The discrepancies between these two methods were recorded as ΔRV%pred, ΔTLC%pred, and ΔRV/TLC. We found that ΔRV%pred, ΔTLC%pred, and ΔRV/TLC increased significantly with the severity of COPD. The differences of lung capacity between these two methods were negatively correlated with FEV 1 %pred, and diffusing capacity for carbon monoxide (D L CO%pred). Moreover, the receiver operating characteristic (ROC) for ΔTLC%pred to distinguish severe COPD from non-severe COPD had an area under curve (AUC) of 0.886. The differences of lung volume parameters measured by body plethysmography and helium dilution methods were associated with airflow limitation and can effectively differentiate COPD severity, which may be a supportive method to assess the lung function of stable COPD patients.

  11. Modulation of Signal Proteins: A Plausible Mechanism to Explain How a Potentized Drug Secale Cor 30C Diluted beyond Avogadro's Limit Combats Skin Papilloma in Mice.

    PubMed

    Khuda-Bukhsh, Anisur Rahman; Bhattacharyya, Soumya Sundar; Paul, Saili; Dutta, Suman; Boujedaini, Naoual; Belon, Philippe

    2011-01-01

    In homeopathy, ability of ultra-high diluted drugs at or above potency 12C (diluted beyond Avogadro's limit) in ameliorating/curing various diseases is often questioned, particularly because the mechanism of action is not precisely known. We tested the hypothesis if suitable modulations of signal proteins could be one of the possible pathways of action of a highly diluted homeopathic drug, Secale cornutum 30C (diluted 10(60) times; Sec cor 30). It could successfully combat DMBA + croton oil-induced skin papilloma in mice as evidenced by histological, cytogenetical, immunofluorescence, ELISA and immunoblot findings. Critical analysis of several signal proteins like AhR, PCNA, Akt, Bcl-2, Bcl-xL, NF-κB and IL-6 and of pro-apoptotic proteins like cytochrome c, Bax, Bad, Apaf, caspase-3 and -9 revealed that Sec cor 30 suitably modulated their expression levels along with amelioration of skin papilloma. FACS data also suggested an increase of cell population at S and G2 phases and decrease in sub-G1 and G1 phages in carcinogen-treated drug-unfed mice, but these were found to be near normal in the Sec cor 30-fed mice. There was reduction in genotoxic and DNA damages in bone marrow cells of Sec Cor 30-fed mice, as revealed from cytogenetic and Comet assays. Changes in histological features of skin papilloma were noted. Immunofluorescence studies of AhR and PCNA also suggested reduced expression of these proteins in Sec cor 30-fed mice, thereby showing its anti-cancer potentials against skin papilloma. Furthermore, this study also supports the hypothesis that potentized homeopathic drugs act at gene regulatory level.

  12. Performance of Two Quantitative PCR Methods for Microbial Source Tracking of Human Sewage and Implications for Microbial Risk Assessment in Recreational Waters

    PubMed Central

    Staley, Christopher; Gordon, Katrina V.; Schoen, Mary E.

    2012-01-01

    Before new, rapid quantitative PCR (qPCR) methods for assessment of recreational water quality and microbial source tracking (MST) can be useful in a regulatory context, an understanding of the ability of the method to detect a DNA target (marker) when the contaminant source has been diluted in environmental waters is needed. This study determined the limits of detection and quantification of the human-associated Bacteroides sp. (HF183) and human polyomavirus (HPyV) qPCR methods for sewage diluted in buffer and in five ambient, Florida water types (estuarine, marine, tannic, lake, and river). HF183 was quantifiable in sewage diluted up to 10−6 in 500-ml ambient-water samples, but HPyVs were not quantifiable in dilutions of >10−4. Specificity, which was assessed using fecal composites from dogs, birds, and cattle, was 100% for HPyVs and 81% for HF183. Quantitative microbial risk assessment (QMRA) estimated the possible norovirus levels in sewage and the human health risk at various sewage dilutions. When juxtaposed with the MST marker detection limits, the QMRA analysis revealed that HF183 was detectable when the modeled risk of gastrointestinal (GI) illness was at or below the benchmark of 10 illnesses per 1,000 exposures, but the HPyV method was generally not sensitive enough to detect potential health risks at the 0.01 threshold for frequency of illness. The tradeoff between sensitivity and specificity in the MST methods indicates that HF183 data should be interpreted judiciously, preferably in conjunction with a more host-specific marker, and that better methods of concentrating HPyVs from environmental waters are needed if this method is to be useful in a watershed management or monitoring context. PMID:22885746

  13. Biodiesel Impact on Engine Lubricant Dilution During Active Regeneration of Aftertreatment Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, X.; Williams, A.; Christensen, E.

    Experiments were conducted with ultra low sulfur diesel (ULSD) and 20% biodiesel blends (B20) to compare lube oil dilution levels and lubricant properties for systems using late in-cylinder fuel injection for aftertreatment regeneration. Lube oil dilution was measured by gas chromatography (GC) following ASTM method D3524 to measure diesel content, by Fourier transform infrared (FTIR) spectrometry following a modified ASTM method D7371 to measure biodiesel content, and by a newly developed back-flush GC method that simultaneously measures both diesel and biodiesel. Heavy-duty (HD) engine testing was conducted on a 2008 6.7L Cummins ISB equipped with a diesel oxidation catalyst (DOC)more » and diesel particle filter (DPF). Stage one of engine testing consisted of 10 consecutive repeats of a forced DPF regeneration event. This continuous operation with late in-cylinder fuel injection served as a method to accelerate lube-oil dilution. Stage two consisted of 16 hours of normal engine operation over a transient test cycle, which created an opportunity for any accumulated fuel in the oil sump to evaporate. Light duty (LD) vehicle testing was conducted on a 2010 VW Jetta equipped with DOC, DPF and a NOx storage catalyst (NSC). Vehicle testing comprised approximately 4,000 miles of operation on a mileage-accumulation dynamometer (MAD) using the U.S. Environmental Protection Agency's Highway Fuel Economy Cycle because of the relatively low engine oil and exhaust temperatures, and high DPF regeneration frequency of this cycle relative to other cycles examined. Comparison of the lube oil dilution analysis methods suggests that D3524 does not measure dilution by biodiesel. The new back-flush GC method provided analysis for both diesel and biodiesel, in a shorter time and with lower detection limit. Thus all lube oil dilution results in this paper are based on this method. Analysis of the HD lube-oil samples showed only 1.5% to 1.6% fuel dilution for both fuels during continuous operation under DPF regeneration events. During the second stage of HD testing, the ULSD lube-oil dilution levels fell from 1.5% to 0.8%, while for B20, lube-oil dilution levels fell from 1.6% to 1.0%, but the fuel in the oil was 36% biodiesel. For the LD vehicle tests, the frequency of DPF regeneration events was observed to be the same for both ULSD and B20. No significant difference between the two fuels' estimated soot loading was detected by the engine control unit (ECU), although a 23% slower rate of increase in differential pressure across DPF was observed with B20. It appears that the ECU estimated soot loading is based on the engine map, not taking advantage of the lower engine-out particulate matter from the use of biodiesel. After 4,000 miles of LD vehicle operation with ULSD, fuel dilution in the lube-oil samples showed total dilution levels of 4.1% diesel. After 4,000 miles of operation with B20, total fuel in oil dilution levels were 6.7% consisting of 3.6% diesel fuel and 3.1% biodiesel. Extrapolation to the 10,000-mile oil drain interval with B20 suggests that the total fuel content in the oil could reach 12%, compared to 5% for operation on ULSD. Analysis of the oil samples also included measurement of total acid number, total base number, viscosity, soot, metals and wear scar; however, little difference in these parameters was noted.« less

  14. Bedside red cell volumetry by low-dose carboxyhaemoglobin dilution using expiratory gas analysis.

    PubMed

    Sawano, M; Mato, T; Tsutsumi, H

    2006-02-01

    We developed a non-invasive, continuous, high-resolution method of measuring carboxyhaemoglobin fraction (COHb%) using expiratory gas analysis (EGA). We assessed whether application of EGA to carboxyhaemoglobin dilution provides red cell volume (RCV) measurement with accuracy equivalent to that of CO-haemoximetry, with a smaller infusion volume of carbon-monoxide-saturated autologous blood (COB). Method. We assessed the agreement between repeated COHb% measurements by EGA and simultaneous measurement by CO-haemoximetry, using Bland and Altman plot, in healthy subjects and patients with artificially controlled ventilation and no radiological evidence of pulmonary oedema or atelectasis. We assessed the agreement between RCV measurements by EGA with infusion of 20 ml of COB (RCVEGA) and RCV measurements by CO-haemoximetry with infusion of 100 ml of COB (RCVHEM), in healthy subjects. The 'limits of agreement' between COHb% measurement by EGA (1 min average) and CO-haemoximetry were -0.09 and 0.08% in healthy subjects, and -0.11 and 0.09% in patients. Given the resolution of CO-haemoximetry (0.1%), the accuracy of EGA was equivalent to or greater than that of CO-haemoximetry. The 'limits of agreement' between RCVEGA and RCVHEM were -0.14 and 0.15 litre. Given the average resolution of RCVHEM (0.14 litre), the accuracy of RCVEGA was equivalent to that of RCVHEM. EGA provided non-invasive, accurate, continuous, high-resolution COHb% measurements. Applying EGA to carboxyhaemoglobin dilution, we achieved RCV measurements with accuracy equivalent to that of CO-haemoximetry, with one-fifth of the COB infusion volume. However, clinical application of the method is limited to patients with no radiological evidence of pulmonary oedema or atelectasis.

  15. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives.

    PubMed

    Reuter, Daniel A; Huang, Cecil; Edrich, Thomas; Shernan, Stanton K; Eltzschig, Holger K

    2010-03-01

    The ability to monitor cardiac output is one of the important cornerstones of hemodynamic assessment for managing critically ill patients at increased risk for developing cardiac complications, and in particular in patients with preexisting cardiovascular comorbidities. For >30 years, single-bolus thermodilution measurement through a pulmonary artery catheter for assessment of cardiac output has been widely accepted as the "clinical standard" for advanced hemodynamic monitoring. In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution technique, such as the transcardiopulmonary thermodilution and lithium dilution techniques. In this review, not only the underlying technical principles and the unique features but also the limitations of each application of indicator dilution are outlined.

  16. Simultaneous analysis of six aldehyde-DNA adducts in salivary DNA of nonsmokers and smokers using stable isotope dilution liquid chromatography electrospray ionization-tandem mass spectrometry.

    PubMed

    Li, Xiangyu; Liu, Lujuan; Wang, Hongjuan; Chen, Jian; Zhu, Beibei; Chen, Huan; Hou, Hongwei; Hu, Qingyuan

    2017-08-15

    A stable method, using isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS), to simultaneously determine six aldehyde-DNA adducts was developed and applied to the analysis of human salivary DNA samples. The detection limit of these six DNA adducts was in the range of 0.006-0.014ng/mL and that of the quantification limit was 0.017-0.026ng/mL. The intra-day and inter-day precision of all aldehyde-DNA adducts was <10%. The analysis was completed within 25min. Additionally, a noninvasive technique was used to collect the DNA samples from human saliva. The new method was successfully applied for the analysis of salivary DNA of nonsmokers and smokers. Five aldehyde-DNA adducts were detected in both smoker and nonsmoker salivary DNA, while α-Acr-dG was not detected in all the samples. Among these detected DNA adducts, no significant differences were found between smoker and nonsmoker (p>0.05). This may due to the individual detoxifying differences or environmental and endogenous exposure. Our study provides a rapid and selective method to simultaneously detect six aldehyde-DNA adducts and to assess potential DNA damage induced by aldehydes. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

    PubMed Central

    Johns, Jennifer L.; Moorhead, Kaitlin A.; Hu, Jing; Moorhead, Roberta C.

    2018-01-01

    Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. PMID:29497614

  18. Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

    NASA Technical Reports Server (NTRS)

    Barile, R. G.; Hodge, T. R.; Meneghelli, B. J.; Gursky, R.; Lueck, D. E.

    1997-01-01

    Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

  19. Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

    NASA Technical Reports Server (NTRS)

    Barile, R. G.; Hodge, T. R.; Meneghelli, B. J.; Gursky, R.; Lueck, D. E.

    1997-01-01

    Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

  20. Designing and Interpreting Limiting Dilution Assays: General Principles and Applications to the Latent Reservoir for Human Immunodeficiency Virus-1.

    PubMed

    Rosenbloom, Daniel I S; Elliott, Oliver; Hill, Alison L; Henrich, Timothy J; Siliciano, Janet M; Siliciano, Robert F

    2015-12-01

    Limiting dilution assays are widely used in infectious disease research. These assays are crucial for current human immunodeficiency virus (HIV)-1 cure research in particular. In this study, we offer new tools to help investigators design and analyze dilution assays based on their specific research needs. Limiting dilution assays are commonly used to measure the extent of infection, and in the context of HIV they represent an essential tool for studying latency and potential curative strategies. Yet standard assay designs may not discern whether an intervention reduces an already miniscule latent infection. This review addresses challenges arising in this setting and in the general use of dilution assays. We illustrate the major statistical method for estimating frequency of infectious units from assay results, and we offer an online tool for computing this estimate. We recommend a procedure for customizing assay design to achieve desired sensitivity and precision goals, subject to experimental constraints. We consider experiments in which no viral outgrowth is observed and explain how using alternatives to viral outgrowth may make measurement of HIV latency more efficient. Finally, we discuss how biological complications, such as probabilistic growth of small infections, alter interpretations of experimental results.

  1. Direct analysis of deodorants for determination of metals by inductively coupled plasma optical emission spectrometry.

    PubMed

    da Costa, Wiviane Kássia Oliveira Correia; da Silva, Caroline Santos; Figueiredo, José Fernando Dagnone; Nóbrega, Joaquim Araujo; Paim, Ana Paula Silveira

    2018-06-05

    A fast and simple dilute-and-shoot procedure for determination of Al, As, Ba, Cd, Cu, Fe, Mg, Mn, Ni, Pb, Sc, Ti, V, Zn and Zr in deodorants by inductively coupled plasma optical emission spectrometry (ICP OES) was developed. Sample preparation was carried out by diluting 1 mL of deodorant sample in 1% (v v -1 ) HNO 3 . The accuracy of the analytical procedure was evaluated using addition and recovery experiments, and recoveries ranged from 80 to 119%. The limits of detection varied from 0.001 to 0.76 mg kg -1 . Nine deodorants samples of different brands were analyzed. The maximum concentrations found (mg kg -1 ) were: Fe (1.0), Mn (0.1), Ti (1.02), V (0.33), Zn (255.2) and Zr (0.5); for Al and Mg, determined concentrations varied from 0.01 to 7.0% and from 0.005 to 1.44 mg kg -1 , respectively, showing wide variation depending on the sample type. The developed procedure was adequate for determining these analytes in routine analysis presenting high sample throughput and demonstrated the feasibility of direct analysis measurements after simple dilution step. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  3. Determination of uranium and thorium in materials associated with real time electronic solar neutrino detectors

    NASA Astrophysics Data System (ADS)

    Fassett, J. D.; Kelly, W. R.

    1992-07-01

    The application of isotope dilution thermal ionization mass spectrometry to the determination of both uranium and thorium in four different target materials used or proposed for electronic neutrino detectors is described. Isotope dilution analysis is done using highly enriched 233U and 230Th separated isotopes. Sensitivity of the technique is such that sub-picogram amounts of material are readily measured. The overall limit to measurement is caused by contamination of these elements during the measurement process. Uranium is more easily measured than thorium because both the instrumental sensitivity is higher and contamination is better controlled. The materials analyzed were light and heavy water, pseudocumene, and mineral oil.

  4. Solid-phase extraction of small biologically active peptides on cartridges and microelution 96-well plates from human urine.

    PubMed

    Semenistaya, Ekaterina; Zvereva, Irina; Krotov, Grigory; Rodchenkov, Grigory

    2016-09-01

    Currently liquid chromatography - mass spectrometry (LC-MS) analysis after solid-phase extraction (SPE) on weak cation-exchange cartridges is a method of choice for anti-doping analysis of small bioactive peptides such as growth hormone releasing peptides (GHRPs), desmoporessin, LHRH, and TB-500 short fragment. Dilution of urine samples with phosphate buffer for pH adjustment and SPE on weak cation exchange microelution plates was tested as a means to increase throughput of this analysis. Dilution using 200 mM phosphate buffer provides good buffering capacity without affecting the peptides recoveries. SPE on microelution plates was performed on Waters Positive Pressure-96 Processor with subsequent evaporation of eluates in nitrogen flow. Though the use of smaller sample volume decreases the pre-concentration factor and increases the limits of detection of 5 out of 17 detected peptides, the recovery, linearity, and reproducibility of the microelution extraction were comparable with cartridge SPE. The effectiveness of protocols was confirmed by analysis of urine samples containing ipamorelin, and GHRP-6 and its metabolites. SPE after urine sample dilution with buffer can be used for faster sample preparation. The use of microelution plates decreases consumption of solvents and allows processing of up to 96 samples simultaneously. Cartridge SPE with manual рН adjustment remains the best option for confirmation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Probabilistic analysis of risks to US drinking water intakes from 1,4-dioxane in domestic wastewater treatment plant effluents.

    PubMed

    Simonich, Staci Massey; Sun, Ping; Casteel, Ken; Dyer, Scott; Wernery, Dave; Garber, Kevin; Carr, Gregory; Federle, Thomas

    2013-10-01

    The risks of 1,4-dioxane (dioxane) concentrations in wastewater treatment plant (WWTP) effluents, receiving primarily domestic wastewater, to downstream drinking water intakes was estimated using distributions of measured dioxane concentrations in effluents from 40 WWTPs and surface water dilution factors of 1323 drinking water intakes across the United States. Effluent samples were spiked with a d8 -1,4-dioxane internal standard in the field immediately after sample collection. Dioxane was extracted with ENVI-CARB-Plus solid phase columns and analyzed by GC/MS/MS, with a limit of quantification of 0.30 μg/L. Measured dioxane concentrations in domestic wastewater effluents ranged from <0.30 to 3.30 μg/L, with a mean concentration of 1.11 ± 0.60 μg/L. Dilution of upstream inputs of effluent were estimated for US drinking water intakes using the iSTREEM model at mean flow conditions, assuming no in-stream loss of dioxane. Dilution factors ranged from 2.6 to 48 113, with a mean of 875. The distributions of dilution factors and dioxane concentration in effluent were then combined using Monte Carlo analysis to estimate dioxane concentrations at drinking water intakes. This analysis showed the probability was negligible (p = 0.0031) that dioxane inputs from upstream WWTPs could result in intake concentrations exceeding the USEPA drinking water advisory concentration of 0.35 μg/L, before any treatment of the water for drinking use. © 2013 SETAC.

  6. Raman Analysis of Dilute Aqueous Samples by Localized Evaporation of Submicroliter Droplets on the Tips of Superhydrophobic Copper Wires.

    PubMed

    Cheung, Melody; Lee, Wendy W Y; McCracken, John N; Larmour, Iain A; Brennan, Steven; Bell, Steven E J

    2016-04-19

    Raman analysis of dilute aqueous solutions is normally prevented by their low signal levels. A very general method to increase the concentration to detectable levels is to evaporate droplets of the sample to dryness, creating solid deposits which are then Raman probed. Here, superhydrophobic (SHP) wires with hydrophilic tips have been used as supports for drying droplets, which have the advantage that the residue is automatically deposited at the tip. The SHP wires were readily prepared in minutes using electroless galvanic deposition of Ag onto copper wires followed by modification with a polyfluorothiol (3,3,4,4,5,5,6,6,7,7,8,8,9,9,10,10,10-heptadecafluoro-1-decanethiol, HDFT). Cutting the coated wires with a scalpel revealed hydrophilic tips which could support droplets whose maximum size was determined by the wire diameter. Typically, 230 μm wires were used to support 0.6 μL droplets. Evaporation of dilute melamine droplets gave solid deposits which could be observed by scanning electron microscopy (SEM) and Raman spectroscopy. The limit of detection for melamine using a two stage evaporation procedure was 1 × 10(-6) mol dm(-3). The physical appearance of dried droplets of sucrose and glucose showed that the samples retained significant amounts of water, even under high vacuum. Nonetheless, the Raman detection limits of sucrose and glucose were 5 × 10(-4) and 2.5 × 10(-3) mol dm(-3), respectively, which is similar to the sensitivity reported for surface-enhanced Raman spectroscopy (SERS) detection of glucose. It was also possible to quantify the two sugars in mixtures at concentrations which were similar to those found in human blood through multivariate analysis.

  7. Development and Evaluation of a Calibrator Material for Nucleic Acid-Based Assays for Diagnosing Aspergillosis

    PubMed Central

    Abdul-Ali, Deborah; Loeffler, Juergen; White, P. Lewis; Wickes, Brian; Herrera, Monica L.; Alexander, Barbara D.; Baden, Lindsey R.; Clancy, Cornelius; Denning, David; Nguyen, M. Hong; Sugrue, Michele; Wheat, L. Joseph; Wingard, John R.; Donnelly, J. Peter; Barnes, Rosemary; Patterson, Thomas F.; Caliendo, Angela M.

    2013-01-01

    Twelve laboratories evaluated candidate material for an Aspergillus DNA calibrator. The DNA material was quantified using limiting-dilution analysis; the mean concentration was determined to be 1.73 × 1010 units/ml. The calibrator can be used to standardize aspergillosis diagnostic assays which detect and/or quantify nucleic acid. PMID:23616459

  8. Development and evaluation of a calibrator material for nucleic acid-based assays for diagnosing aspergillosis.

    PubMed

    Lyon, G Marshall; Abdul-Ali, Deborah; Loeffler, Juergen; White, P Lewis; Wickes, Brian; Herrera, Monica L; Alexander, Barbara D; Baden, Lindsey R; Clancy, Cornelius; Denning, David; Nguyen, M Hong; Sugrue, Michele; Wheat, L Joseph; Wingard, John R; Donnelly, J Peter; Barnes, Rosemary; Patterson, Thomas F; Caliendo, Angela M

    2013-07-01

    Twelve laboratories evaluated candidate material for an Aspergillus DNA calibrator. The DNA material was quantified using limiting-dilution analysis; the mean concentration was determined to be 1.73 × 10(10) units/ml. The calibrator can be used to standardize aspergillosis diagnostic assays which detect and/or quantify nucleic acid.

  9. Highly sensitive and selective hyphenated technique (molecularly imprinted polymer solid-phase microextraction-molecularly imprinted polymer sensor) for ultra trace analysis of aspartic acid enantiomers.

    PubMed

    Prasad, Bhim Bali; Srivastava, Amrita; Tiwari, Mahavir Prasad

    2013-03-29

    The present work is related to combination of molecularly imprinted solid-phase microextraction and complementary molecularly imprinted polymer-sensor. The molecularly imprinted polymer grafted on titanium dioxide modified silica fiber was used for microextraction, while the same polymer immobilized on multiwalled carbon nanotubes/titanium dioxide modified pencil graphite electrode served as a detection tool. In both cases, the surface initiated polymerization was found to be advantageous to obtain a nanometer thin imprinted film. The modified silica fiber exhibited high adsorption capacity and enantioselective diffusion of aspartic acid isomers into respective molecular cavities. This combination enabled double preconcentrations of d- and l-aspartic acid that helped sensing both isomers in real samples, without any cross-selectivity and matrix complications. Taking into account 6×10(4)-fold dilution of serum and 2×10(3)-fold dilution of cerebrospinal fluid required by the proposed method, the limit of detection for l-aspartic acid is 0.031ngmL(-1). Also, taking into account 50-fold dilution required by the proposed method, the limit of detection for d-aspartic acid is 0.031ngmL(-1) in cerebrospinal fluid. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Community-Level Physiological Profiling of Microbial Communities in Constructed Wetlands: Effects of Sample Preparation.

    PubMed

    Button, Mark; Weber, Kela; Nivala, Jaime; Aubron, Thomas; Müller, Roland Arno

    2016-03-01

    Community-level physiological profiling (CLPP) using BIOLOG® EcoPlates™ has become a popular method for characterizing and comparing the functional diversity, functional potential, and metabolic activity of heterotrophic microbial communities. The method was originally developed for profiling soil communities; however, its usage has expanded into the fields of ecotoxicology, agronomy, and the monitoring and profiling of microbial communities in various wastewater treatment systems, including constructed wetlands for water pollution control. When performing CLPP on aqueous samples from constructed wetlands, a wide variety of sample characteristics can be encountered and challenges may arise due to excessive solids, color, or turbidity. The aim of this study was to investigate the impacts of different sample preparation methods on CLPP performed on a variety of aqueous samples covering a broad range of physical and chemical characteristics. The results show that using filter paper, centrifugation, or settling helped clarify samples for subsequent CLPP analysis, however did not do so as effectively as dilution for the darkest samples. Dilution was able to provide suitable clarity for the darkest samples; however, 100-fold dilution significantly affected the carbon source utilization patterns (CSUPs), particularly with samples that were already partially or fully clear. Ten-fold dilution also had some effect on the CSUPs of samples which were originally clear; however, the effect was minimal. Based on these findings, for this specific set of samples, a 10-fold dilution provided a good balance between ease of use, sufficient clarity (for dark samples), and limited effect on CSUPs. The process and findings outlined here can hopefully serve future studies looking to utilize CLPP for functional analysis of microbial communities and also assist in comparing data from studies where different sample preparation methods were utilized.

  11. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    PubMed

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  12. Lab tests on the biodegradation of chemically dispersed oil should consider the rapid dilution that occurs at sea.

    PubMed

    Lee, Kenneth; Nedwed, Tim; Prince, Roger C; Palandro, David

    2013-08-15

    Most crude oils spread on open water to an average thickness as low as 0.1 mm. The application of dispersants enhances the transport of oil as small droplets into the water column, and when combined with the turbulence of 1 m waves will quickly entrain oil into the top 1 m of the water column, where it rapidly dilutes to concentrations less than 100 ppm. In less than 24 h, the dispersed oil is expected to mix into the top 10 m of the water column and be diluted to concentrations well below 10 ppm, with dilution continuing as time proceeds. Over the multiple weeks that biodegradation takes place, dispersed oil concentrations are expected to be below 1 ppm. Measurements from spills and wave basin studies support these calculations. Published laboratory studies focused on the quantification of contaminant biodegradation rates have used concentrations orders of magnitude greater than this, as it was necessary to ensure the concentrations of hydrocarbons and other chemicals were higher than the detection limits of chemical analysis. However, current analytical methods can quantify individual alkanes and PAHs (and their alkyl homologues) at ppb and ppm levels. To simulate marine biodegradation of dispersed oil at dilute concentrations commonly encountered in the field, laboratory studies should be conducted at similarly low hydrocarbon concentrations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Determination of 232Th in urine by ICP-MS for individual monitoring purposes.

    PubMed

    Baglan, N; Cossonnet, C; Ritt, J

    2001-07-01

    Thorium is naturally occurring in various ores used for industrial purposes and has numerous applications. This paper sets out to investigate urine analysis as a suitable monitoring approach for workers potentially exposed to thorium. Due to its biokinetic behavior and its low solubility, urinary concentrations are generally very low, requiring therefore high sensitivity analytical methods. An analytical procedure has been developed for detecting 232Th concentrations of below 1 mBq L(-1) quickly and easily. Due to the long half-life (1.41 x 10(10) y) of 232Th, the potential of a procedure based on urine sample dilution and ICP-MS (inductively coupled plasma-mass spectrometry) measurement was investigated first. Two dilution factors were chosen: 100, which is more suitable for long-term measurement trials, and 20, which increases sensitivity. It has been shown that a 100-fold dilution can be used to measure concentrations of below 1 mBq L(-1), whereas a 20-fold one can be used to reach concentrations of below 0.06 mBq L(-1). Then, on the basis of the limitation of the procedure based on urine dilution, the suitable field of application for the different procedures (100-fold and 20-fold dilution and also a chemical purification followed by an ICP-MS measurement) was determined in relation to monitoring objectives.

  14. Analysis of Cyclic Variability of Heat Release for High-EGR GDI Engine Operation with Observations on Implications for Effective Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaul, Brian C; Wagner, Robert M; Green Jr, Johney Boyd

    2013-01-01

    Operation of spark-ignition (SI) engines with high levels of charge dilution through exhaust gas recirculation (EGR) achieves significant engine efficiency gains while maintaining stoichiometric operation for compatibility with three-way catalysts. Dilution levels, however, are limited by cyclic variability-including significant numbers of misfires-that becomes more pronounced with increasing dilution. This variability has been shown to have both stochastic and deterministic components. Stochastic effects include turbulence, mixing variations, and the like, while the deterministic effect is primarily due to the nonlinear dependence of flame propagation rates and ignition characteristics on the charge composition, which is influenced by the composition of residual gasesmore » from prior cycles. The presence of determinism implies that an increased understanding the dynamics of such systems could lead to effective control approaches that allow operation near the edge of stability, effectively extending the dilution limit. This nonlinear dependence has been characterized previously for homogeneous charge, port fuel-injected (PFI) SI engines operating fuel-lean as well as with inert diluents such as bottled N2 gas. In this paper, cyclic dispersion in a modern boosted gasoline direct injection (GDI) engine using a cooled external EGR loop is examined, and the potential for improvement with effective control is evaluated through the use of symbol sequence statistics and other techniques from chaos theory. Observations related to the potential implications of these results for control approaches that could effectively enable engine operation at the edge of combustion stability are noted.« less

  15. 1H NMR quantification in very dilute toxin solutions: application to anatoxin-a analysis.

    PubMed

    Dagnino, Denise; Schripsema, Jan

    2005-08-01

    A complete procedure is described for the extraction, detection and quantification of anatoxin-a in biological samples. Anatoxin-a is extracted from biomass by a routine acid base extraction. The extract is analysed by GC-MS, without the need of derivatization, with a detection limit of 0.5 ng. A method was developed for the accurate quantification of anatoxin-a in the standard solution to be used for the calibration of the GC analysis. 1H NMR allowed the accurate quantification of microgram quantities of anatoxin-a. The accurate quantification of compounds in standard solutions is rarely discussed, but for compounds like anatoxin-a (toxins with prices in the range of a million dollar a gram), of which generally only milligram quantities or less are available, this factor in the quantitative analysis is certainly not trivial. The method that was developed can easily be adapted for the accurate quantification of other toxins in very dilute solutions.

  16. Irena : tool suite for modeling and analysis of small-angle scattering.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilavsky, J.; Jemian, P.

    2009-04-01

    Irena, a tool suite for analysis of both X-ray and neutron small-angle scattering (SAS) data within the commercial Igor Pro application, brings together a comprehensive suite of tools useful for investigations in materials science, physics, chemistry, polymer science and other fields. In addition to Guinier and Porod fits, the suite combines a variety of advanced SAS data evaluation tools for the modeling of size distribution in the dilute limit using maximum entropy and other methods, dilute limit small-angle scattering from multiple non-interacting populations of scatterers, the pair-distance distribution function, a unified fit, the Debye-Bueche model, the reflectivity (X-ray and neutron)more » using Parratt's formalism, and small-angle diffraction. There are also a number of support tools, such as a data import/export tool supporting a broad sampling of common data formats, a data modification tool, a presentation-quality graphics tool optimized for small-angle scattering data, and a neutron and X-ray scattering contrast calculator. These tools are brought together into one suite with consistent interfaces and functionality. The suite allows robust automated note recording and saving of parameters during export.« less

  17. ¹³C-based metabolic flux analysis of Saccharomyces cerevisiae with a reduced Crabtree effect.

    PubMed

    Kajihata, Shuichi; Matsuda, Fumio; Yoshimi, Mika; Hayakawa, Kenshi; Furusawa, Chikara; Kanda, Akihisa; Shimizu, Hiroshi

    2015-08-01

    Saccharomyces cerevisiae shows a Crabtree effect that produces ethanol in a high glucose concentration even under fully aerobic condition. For efficient production of cake yeast or compressed yeast for baking, ethanol by-production is not desired since glucose limited chemostat or fed-batch cultivations are performed to suppress the Crabtree effect. In this study, the (13)C-based metabolic flux analysis ((13)C-MFA) was performed for the S288C derived S. cerevisiae strain to characterize a metabolic state under the reduced Crabtree effect. S. cerevisiae cells were cultured at a low dilution rate (0.1 h(-1)) under the glucose-limited chemostat condition. The estimated metabolic flux distribution showed that the acetyl-CoA in mitochondria was mainly produced from pyruvate by pyruvate dehydrogenase (PDH) reaction and that the level of the metabolic flux through the pentose phosphate pathway was much higher than that of the Embden-Meyerhof-Parnas pathway, which contributes to high biomass yield at low dilution rate by supplying NADPH required for cell growth. Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. Effect of semen preparation on casa motility results in cryopreserved bull spermatozoa.

    PubMed

    Contri, Alberto; Valorz, Claudio; Faustini, Massimo; Wegher, Laura; Carluccio, Augusto

    2010-08-01

    Computer-assisted sperm analyzers (CASA) have become the standard tool for evaluating sperm motility and kinetic patterns because they provide objective data for thousands of sperm tracks. However, these devices are not ready-to-use and standardization of analytical practices is a fundamental requirement. In this study, we evaluated the effects of some settings, such as frame rate and frames per field, chamber and time of analysis, and samples preparations, including thawing temperature, sperm sample concentration, and media used for dilution, on the kinetic results of bovine frozen-thawed semen using a CASA. In Experiment 1, the frame rate (30-60 frame/s) significantly affected motility parameters, whereas the number of frames per field (30 or 45) did not seem to affect sperm kinetics. In Experiment 2, the thawing protocol affects sperm motility and kinetic parameters. Sperm sample concentration significantly limited the opportunity to perform the analysis and the kinetic results. A concentration of 100 and 50 x 10(6) sperm/mL limited the device's ability to perform the analysis or gave wrong results, whereas 5, 10, 20, and 30 x 10(6) sperm/mL concentrations allowed the analysis to be performed, but with different results (Experiment 3). The medium used for the dilution of the sample, which is fundamental for a correct sperm head detection, affects sperm motility results (Experiment 4). In this study, Makler and Leja chambers were used to perform the semen analysis with CASA devices. The chamber used significantly affected motility results (Experiment 5). The time between chamber loading and analysis affected sperm velocities, regardless of chamber used. Based on results recorded in this study, we propose that the CASA evaluation of motility of bovine frozen-thawed semen using Hamilton-Thorne IVOS 12.3 should be performed using a frame rate of 60 frame/s and 30 frames per field. Semen should be diluted at least at 20 x 10(6) sperm/mL using PBS. Furthermore, it is necessary to consider the type of chamber used and perform the analysis within 1 or 2 min, regardless of the chamber used. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Detection of placental alpha microglobulin-1 versus insulin-like growth factor-binding protein-1 in amniotic fluid at term: a comparative study.

    PubMed

    Pollet-Villard, Marie; Cartier, Régine; Gaucherand, Pascal; Doret, Muriel

    2011-06-01

    We compared two biochemical tests of premature rupture of membranes (PROM) in vitro: Actim PROM (Medix Biochemica, Kauniainen, Finland), which detects insulin-like growth factor binding protein-1, and AmniSure (AmniSure International LLC, Cambridge, MA), which detects placental alpha microglobulin-1. Samples of amniotic fluid were collected during caesarean section in 41 patients. A dilution series was prepared and both tests were performed twice at each dilution. Sensitivity, detection limit, response time, and reproducibility of both tests were compared. Both tests' sensitivity was 100% at dilution 1:10 and 1:20. AmniSure sensitivity was higher at dilution 1:40 and 1:80 ( P < 0.05). In 29 of 40 cases, AmniSure had a lower detection limit than Actim PROM. AmniSure response times were shorter and reproducibility was higher than Actim PROM ( P < 0.05). AmniSure had a lower detection limit of amniotic fluid than Actim PROM, with a shorter response time, a higher sensitivity, and a better reproducibility. © Thieme Medical Publishers.

  20. Performance of a commercial serum ELISA for the detection of antibodies to Neospora caninum in whole and skim milk samples.

    PubMed

    Byrem, T M; Bartlett, P C; Donohue, H; Voisinet, B D; Houseman, J T

    2012-11-23

    Control of Neospora caninum infection in cattle depends on specific, ante-mortem detection of infected animals and limiting their use as breeding stock or by culling. The objective of the present study was to determine appropriate cut-off values and diagnostic performance of a milk ELISA test using whole and skim milk in a commercial serum ELISA test (IDEXX Neospora Ab). Serum and milk samples were obtained from a total of 475 lactating cows from two herds with and two herds without a previous history of N. caninum-associated abortion. Overall seroprevalence determined by the ELISA was 18.3%. Compared to serum ELISA values, correlation and overall performance assessed by receiver operating characteristic analysis was higher when either whole or skim milk samples were diluted 1:2 compared to undiluted or 1:5 diluted samples. Diagnostic performance for analysis of whole and skim milk was compared at cut-off values that achieved a desired operating characteristic of at least 95% specificity. For whole milk diluted 1:2 and a cut-off of 0.14 (S/P ratio), sensitivity and kappa values were 74.7% (95% CI 64.3-83.4) and 0.70 (95% CI 0.61-0.78), respectively. For skim milk diluted 1:2 and a cut-off of 0.30, sensitivity and kappa values were 77.0% (95% CI 66.8-85.4) and 0.72 (95% CI 0.64-0.80), respectively. Using the selected cut-offs, the IDEXX Neospora Ab Test is equally suited for the analysis of whole and skim milk as a screening tool in neosporosis control programs. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis.

    PubMed

    Milani, Gregorio P; Groothoff, Jaap W; Vianello, Federica A; Fossali, Emilio F; Paglialonga, Fabio; Edefonti, Alberto; Agostoni, Carlo; Consonni, Dario; van Harskamp, Dewi; van Goudoever, Johannes B; Schierbeek, Henk; Oosterveld, Michiel J S

    2017-03-01

    Assessment of hydration status in patients with chronic kidney failure treated by dialysis is crucial for clinical management decisions. Dilution techniques are considered the gold standard for measurement of body fluid volumes, but they are unfit for day-to-day care. Multifrequency bioimpedance has been shown to be of help in clinical practice in adults and its use in children and adolescents has been advocated. We investigated whether application of multifrequency bioimpedance is appropriate for total-body water (TBW) and extracellular water (ECW) measurement in children and adolescents on dialysis therapy. A study of diagnostic test accuracy. 16 young dialysis patients (before a hemodialysis session or after peritoneal dialysis treatment) from the Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy, and the Emma Children's Hospital-Academic Medical Center, Amsterdam, the Netherlands. TBW and ECW volumes assessed by multifrequency bioimpedance. TBW and ECW volumes measured by deuterium and bromide dilution, respectively. Mean TBW volumes determined by multifrequency bioimpedance and deuterium dilution were 19.2±8.7 (SD) and 19.3±8.3L, respectively; Bland-Altman analysis showed a mean bias between the 2 methods of -0.09 (95% limits of agreement, -2.1 to 1.9) L. Mean ECW volumes were 8.9±4.0 and 8.3±3.3L measured by multifrequency bioimpedance and bromide dilution, respectively; mean bias between the 2 ECW measurements was +0.6 (95% limits of agreement, -2.3 to 3.5). Participants ingested the deuterated water at home without direct supervision by investigators, small number of patients, repeated measurements in individual patients were not performed. Multifrequency bioimpedance measurements were unbiased but imprecise in comparison to dilution techniques. We conclude that multifrequency bioimpedance measurements cannot precisely estimate TBW and ECW in children receiving dialysis. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  2. Influence of interfacial slip on the suspension rheology of a dilute emulsion of surfactant-laden deformable drops in linear flows

    NASA Astrophysics Data System (ADS)

    Das, Sayan; Bhattacharjee, Anirban; Chakraborty, Suman

    2018-03-01

    The present study deals with the effect of interfacial slip on the deformation and emulsion rheology of a dilute suspension of droplets in a linear flow. The droplets are laden with surfactants that are bulk-insoluble and get transported only along the interface. An asymptotic approach is adopted for the present analysis in order to tackle the nonlinearity present due to deformation of droplets. The analysis is carried out for two different limiting scenarios, namely, surface diffusion-dominated-surfactant transport and surface convection-dominated surfactant transport. For either of the limiting cases, we look into the droplet dynamics for two commonly encountered bulk flows—uniaxial extensional and simple shear flow. Under the assumption of negligible fluid inertia in either phase, it is shown that slip at the droplet interface significantly affects the surfactant-induced Marangoni stress and hence droplet deformation and emulsion rheology. The presence of interfacial slip not only brings about a decrease in the droplet deformation but also reduces the effective viscosity of the emulsion. The fall in both droplet deformation and effective viscosity is found to be more severe for the limiting case of surface convection-dominated surfactant transport. For the case of an imposed simple shear flow, the normal stress differences generated due to droplet deformation are affected as well due to the presence of interfacial slip.

  3. Approaches of aroma extraction dilution analysis (AEDA) for headspace solid phase microextraction and gas chromatography-olfactometry (HS-SPME-GC-O): Altering sample amount, diluting the sample or adjusting split ratio?

    PubMed

    Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming

    2015-11-15

    Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.

  4. The Effect of Dilution on the Structure of Microbial Communities

    NASA Technical Reports Server (NTRS)

    Mills, Aaron L.

    2000-01-01

    To determine how dilution of microbial communities affects the diversity of the diluted assemblage a series of numerical simulations were conducted that determined the theoretical change in diversity, richness, and evenness of the community with serial dilution. The results of the simulation suggested that the effects are non linear with a high degree of dependence on the initial evenness of the community being diluted. A series of incubation experiments using a range of dilutions of raw sewage as an inoculum into sterile sewage was used for comparison to the simulations. The diluted communities were maintained in batch fed reactors (three day retention time) for nine days. The communities were harvested and examined by conventional plating and by molecular analysis of the whole-community DNA using AFLP and T-RFLP. Additional, CLPP analysis was also applied. The effects on richness predicted by the numerical simulations were confirmed by the analyses used. The diluted communities fell into three groups, a low dilution, intermediate dilution, and high dilution group, which corresponded well with the groupings obtained for community richness in simulation. The grouping demonstrated the non-linear nature of dilution of whole communities. Furthermore, the results implied that the undiluted community consisted of a few dominant types accompanied by a number of rare (low abundance) types as is typical in unevenly distributed communities.

  5. Controlled biomass formation and kinetics of toluene degradation in a bioscrubber and in a reactor with a periodically moved trickle-bed.

    PubMed

    Wübker, S M; Laurenzis, A; Werner, U; Friedrich, C

    1997-08-20

    The kinetics of degradation of toluene from a model waste gas and of biomass formation were examined in a bioscrubber operated under different nutrient limitations with a mixed culture. The applicability of the kinetics of continuous cultivation of the mixed culture was examined for a special trickle-bed reactor with a periodically moved filter bed. The efficiency of toluene elimination of the bioscrubber was 50 to 57% and depended on the toluene mass transfer as evident from a constant productivity of 0.026 g dry cell weight/L . h over the dilution rate. Under potassium limitation the biomass productivity was reduced by 60% to 0.011 g dry cell weight/L . h at a dilution rate of 0.013/h. Conversely, at low dilution rates the specific toluene degradation rates increased. Excess biomass in a trickle-bed reactor causes reduction of interfacial area and mass transfer, and increase in pressure drop. To avoid these disadvantages, the trickle-bed was moved periodically and biomass was removed with outflowing medium. The concentration of steady state biomass fixed on polyamide beads decreased hyperbolically with the dilution rate. Also, the efficiency of toluene degradation decreased from 72 to 56% with increasing dilution rate while the productivity increased. Potassium limitation generally caused a reduction in biomass, productivity, and yield while the specific degradation increased with dilution rate. This allowed the application of the principles of the chemostat to the trickle-bed reactor described here, for toluene degradation from waste gases. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 55: 686-692, 1997.

  6. Infectivity and RNA patterns as functions of high- and low-dilution passage of murine sarcoma-leukemia virus: evidence for autointerference within an oncornavirus population.

    PubMed

    Bondurant, M C; Hackett, A J; Schaffer, F L

    1973-05-01

    Heterogeneity of buoyant density and RNA content of virions of Moloney murine leukemia-sarcoma complex [MSV (MLV)] was the result of passage at low dilution. Heterogeneous stocks revealed two major RNA components in the population, with the smaller component, apparent mol wt 4 x 10(6) to 5 x 10(6), becoming predominant upon serial passage at low dilution. Concomitantly, infectivity titers of both MLV and MSV decreased upon serial passage at low dilution. MSV (MLV) passaged at high dilution retained high titers and a rather homogeneous high-molecular-weight RNA population characteristic of high-buoyant-density virions. Interference of both MLV and MSV replication was demonstrated by employing mixed inocula containing both low- and high-dilution passage stocks of MSV (MLV). In contrast to results with MSV (MLV), MLV freed of MSV by limit dilution did not show heterogeneity of buoyant density or of RNA when propagated at low dilution.

  7. Infectivity and RNA Patterns as Functions of High- and Low-Dilution Passage of Murine Sarcoma-Leukemia Virus: Evidence for Autointerference Within an Oncornavirus Population

    PubMed Central

    Bondurant, M. C.; Hackett, A. J.; Schaffer, F. L.

    1973-01-01

    Heterogeneity of buoyant density and RNA content of virions of Moloney murine leukemia-sarcoma complex [MSV (MLV)] was the result of passage at low dilution. Heterogeneous stocks revealed two major RNA components in the population, with the smaller component, apparent mol wt 4 × 106 to 5 × 106, becoming predominant upon serial passage at low dilution. Concomitantly, infectivity titers of both MLV and MSV decreased upon serial passage at low dilution. MSV (MLV) passaged at high dilution retained high titers and a rather homogeneous high-molecular-weight RNA population characteristic of high-buoyant-density virions. Interference of both MLV and MSV replication was demonstrated by employing mixed inocula containing both low- and high-dilution passage stocks of MSV (MLV). In contrast to results with MSV (MLV), MLV freed of MSV by limit dilution did not show heterogeneity of buoyant density or of RNA when propagated at low dilution. PMID:4350709

  8. Use of wind data for estimating horizontal dilution potential of atmosphere.

    PubMed

    George, K V; Verma, P; Devotta, S

    2007-04-01

    In this study, a new methodology is suggested for estimating horizontal dilution potential of an area using wind data. The mean wind speed and wind direction variation are used as a measure of linear and angular spread of pollutants in the atmosphere. A formula is developed for estimating the potential of horizontal spread of pollutants in an area wherein only the wind speed and direction are used. The methodology is further applied to monitor wind data of one year. It is found that there is a very smooth variation of horizontal dilution potential over a year with limited dilution during post monsoon period and a high dilution in pre monsoon period.

  9. Viscosity of a concentrated suspension of rigid monosized particles

    NASA Astrophysics Data System (ADS)

    Brouwers, H. J. H.

    2010-05-01

    This paper addresses the relative viscosity of concentrated suspensions loaded with unimodal hard particles. So far, exact equations have only been put forward in the dilute limit, e.g., by Einstein [A. Einstein, Ann. Phys. 19, 289 (1906) (in German); Ann. Phys. 34, 591 (1911) (in German)] for spheres. For larger concentrations, a number of phenomenological models for the relative viscosity was presented, which depend on particle concentration only. Here, an original and exact closed form expression is derived based on geometrical considerations that predicts the viscosity of a concentrated suspension of monosized particles. This master curve for the suspension viscosity is governed by the relative viscosity-concentration gradient in the dilute limit (for spheres the Einstein limit) and by random close packing of the unimodal particles in the concentrated limit. The analytical expression of the relative viscosity is thoroughly compared with experiments and simulations reported in the literature, concerning both dilute and concentrated suspensions of spheres, and good agreement is found.

  10. Online Measurement of Exhaled NO Concentration and Its Production Sites by Fast Non-equilibrium Dilution Ion Mobility Spectrometry

    NASA Astrophysics Data System (ADS)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Liu, Jiwei; Li, Haiyang

    2016-03-01

    Exhaled nitric oxide (NO) is one of the most promising breath markers for respiratory diseases. Its profile for exhalation and the respiratory NO production sites can provide useful information for medical disease diagnosis and therapeutic procedures. However, the high-level moisture in exhaled gas always leads to the poor selectivity and sensitivity for ion spectrometric techniques. Herein, a method based on fast non-equilibrium dilution ion mobility spectrometry (NED-IMS) was firstly proposed to directly monitor the exhaled NO profile on line. The moisture interference was eliminated by turbulently diluting the original moisture to 21% of the original with the drift gas and dilution gas. Weak enhancement was observed for humid NO response and its limit of detection at 100% relative humidity was down to 0.58 ppb. The NO concentrations at multiple exhalation flow rates were measured, while its respiratory production sites were determined by using two-compartment model (2CM) and Högman and Meriläinen algorithm (HMA). Last but not the least, the NO production sites were analyzed hourly to tentatively investigate the daily physiological process of NO. The results demonstrated the capacity of NED-IMS in the real-time analysis of exhaled NO and its production sites for clinical diagnosis and assessment.

  11. Increasing the accuracy and scalability of the Immunofluorescence Assay for Epstein Barr Virus by inferring continuous titers from a single sample dilution.

    PubMed

    Goh, Sherry Meow Peng; Swaminathan, Muthukaruppan; Lai, Julian U-Ming; Anwar, Azlinda; Chan, Soh Ha; Cheong, Ian

    2017-01-01

    High Epstein Barr Virus (EBV) titers detected by the indirect Immunofluorescence Assay (IFA) are a reliable predictor of Nasopharyngeal Carcinoma (NPC). Despite being the gold standard for serological detection of NPC, the IFA is limited by scaling bottlenecks. Specifically, 5 serial dilutions of each patient sample must be prepared and visually matched by an evaluator to one of 5 discrete titers. Here, we describe a simple method for inferring continuous EBV titers from IFA images acquired from NPC-positive patient sera using only a single sample dilution. In the first part of our study, 2 blinded evaluators used a set of reference titer standards to perform independent re-evaluations of historical samples with known titers. Besides exhibiting high inter-evaluator agreement, both evaluators were also in high concordance with historical titers, thus validating the accuracy of the reference titer standards. In the second part of the study, the reference titer standards were IFA-processed and assigned an 'EBV Score' using image analysis. A log-linear relationship between titers and EBV Score was observed. This relationship was preserved even when images were acquired and analyzed 3days post-IFA. We conclude that image analysis of IFA-processed samples can be used to infer a continuous EBV titer with just a single dilution of NPC-positive patient sera. This work opens new possibilities for improving the accuracy and scalability of IFA in the context of clinical screening. Copyright © 2016. Published by Elsevier B.V.

  12. Chemical footprint method for improved communication of freshwater ecotoxicity impacts in the context of ecological limits.

    PubMed

    Bjørn, Anders; Diamond, Miriam; Birkved, Morten; Hauschild, Michael Zwicky

    2014-11-18

    The ecological footprint method has been successful in communicating environmental impacts of anthropogenic activities in the context of ecological limits. We introduce a chemical footprint method that expresses ecotoxicity impacts from anthropogenic chemical emissions as the dilution needed to avoid freshwater ecosystem damage. The indicator is based on USEtox characterization factors with a modified toxicity reference point. Chemical footprint results can be compared to the actual dilution capacity within the geographic vicinity receiving the emissions to estimate whether its ecological limit has been exceeded and hence whether emissions can be expected to be environmentally sustainable. The footprint method was illustrated using two case studies. The first was all inventoried emissions from European countries and selected metropolitan areas in 2004, which indicated that the dilution capacity was likely exceeded for most European countries and all landlocked metropolitan areas. The second case study indicated that peak application of pesticides alone was likely to exceed Denmark's freshwater dilution capacity in 1999-2011. The uncertainty assessment showed that better spatially differentiated fate factors would be useful and pointed out other major sources of uncertainty and some opportunities to reduce these.

  13. Characterization and Behavior of Cold Lake Blend and Western Canadian Select Diluted Bitumen Products

    EPA Science Inventory

    Unconventional diluted bitumen (dilbit) oil products present an increasing environmental concern because of extensive transport in North America, recent spills into aquatic habitats, and limited understanding of environmental fate and toxicity. Dilbits are blends of highly weathe...

  14. Matrix-effect free multi-residue analysis of veterinary drugs in food samples of animal origin by nanoflow liquid chromatography high resolution mass spectrometry.

    PubMed

    Alcántara-Durán, Jaime; Moreno-González, David; Gilbert-López, Bienvenida; Molina-Díaz, Antonio; García-Reyes, Juan F

    2018-04-15

    In this work, a sensitive method based on nanoflow liquid chromatography high-resolution mass spectrometry has been developed for the multiresidue determination of veterinary drugs residues in honey, veal muscle, egg and milk. Salting-out supported liquid extraction was employed as sample treatment for milk, veal muscle and egg, while a modified QuEChERS procedure was used in honey. The enhancement of sensitivity provided by the nanoflow LC system also allowed the implementation of high dilution factors as high as 100:1. For all matrices tested, matrix effects were negligible starting from a dilution factor of 100, enabling, thus, the use of external standard calibration instead of matrix-matched calibration of each sample, and the subsequent increase of laboratory throughput. At spiked levels as low as 0.1 or 1 µg kg -1 before the 1:100 dilution, the obtained signals were still significantly higher than the instrumental limit of quantitation (S/N 10). Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Study of static and dynamic magnetic properties of Fe nanoparticles composited with activated carbon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pal, Satyendra Prakash, E-mail: sppal85@gmail.com; Department of Physical Sciences, Indian Institute of Science Education and Research, Mohali, Knowledge city, Sector81, SAS Nagar, Manauli-140306, Punjab; Kaur, Guratinder

    2016-05-23

    Nanocomposite of Fe nanoparticles with activated carbon has been synthesized to alter the magnetic spin-spin interaction and hence study the dilution effect on the static and dynamic magnetic properties of the Fe nanoparticle system. Transmission electron microscopic (TEM) image shows the spherical Fe nanoparticles dispersed in carbon matrix with 13.8 nm particle size. Temperature dependent magnetization measurement does not show any blocking temperature at all, right up to the room temperature. Magnetic hysteresis curve, taken at 300 K, shows small value of the coercivity and this small hysteresis indicates the presence of an energy barrier and inherent magnetization dynamics. Langevinmore » function fitting of the hysteresis curve gives almost similar value of particle size as obtained from TEM analysis. Magnetic relaxation data, taken at a temperature of 100 K, were fitted with a combination of two exponentially decaying function. This diluted form of nanoparticle system, which has particles size in the superparamagnetic limit, behaves like a dilute ensemble of superspins with large value of the magnetic anisotropic barrier.« less

  16. Detoxification of corn stover and corn starch pyrolysis liquors by Pseudomonas putida and Streptomyces setonii suspended cells and plastic compost support biofilms.

    PubMed

    Khiyami, Mohammad A; Pometto Iii, Anthony L; Brown, Robert C

    2005-04-20

    Plant biomass can be liquefied into fermentable sugars (levoglucosan then to glucose) for the production of ethanol, lactic acid, enzymes, and more by a process called pyrolysis. During the process microbial inhibitors are also generated. Pseudomonas putida (ATCC 17484) and Streptomyces setonii75Vi2 (ATCC 39116) were employed to degrade microbial inhibitors in diluted corn stover (Dcs) and diluted corn starch (Dst) pyrolysis liquors. The detoxification process evaluation included measuring total phenols and changes in UV spectra, a GC-MS analysis, and a bioassay, which employed Lactobacillus casei subsp. rhamosus (ATCC 11443) growth as an indicator of detoxification. Suspended-cell cultures illustrated limited detoxification ability of Dcs and Dst. P. putida and S. setoniiplastic compost support (PCS) biofilm continuous-stirred-tank-reactor pure cultures detoxified 10 and 25% (v/v) Dcs and Dst, whereas PCS biofilm mixed culture also partially detoxified 50% (v/v) Dcs and Dst in repeated batch culture. Therefore, PCS biofilm mixed culture is the process of choice to detoxify diluted pyrolysis liquors.

  17. Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Garbarino, John R.; Taylor, Howard E.

    1987-01-01

    Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.

  18. Direct analysis of psychoactive tryptamine and harmala alkaloids in the Amazonian botanical medicine ayahuasca by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    McIlhenny, Ethan H; Pipkin, Kelly E; Standish, Leanna J; Wechkin, Hope A; Strassman, Rick; Barker, Steven A

    2009-12-18

    A direct injection/liquid chromatography-electrospray ionization-tandem mass spectrometry procedure has been developed for the simultaneous quantitation of 11 compounds potentially found in the increasingly popular Amazonian botanical medicine and religious sacrament ayahuasca. The method utilizes a deuterated internal standard for quantitation and affords rapid detection of the alkaloids by a simple dilution assay, requiring no extraction procedures. Further, the method demonstrates a high degree of specificity for the compounds in question, as well as low limits of detection and quantitation despite using samples for analysis that had been diluted up to 200:1. This approach also appears to eliminate potential matrix effects. Method bias for each compound, examined over a range of concentrations, was also determined as was inter- and intra-assay variation. Its application to the analysis of three different ayahuasca preparations is also described. This method should prove useful in the study of ayahuasca in clinical and ethnobotanical research as well as in forensic examinations of ayahuasca preparations.

  19. Reactivity of Pleistocene aged organic matter in the Siberian Arctic

    NASA Astrophysics Data System (ADS)

    Davydov, S.; Vonk, J. E.; Mann, P. J.; Davydova, A.; Sobczak, W. V.; Schade, J. D.; Bulygina, E. B.; Zimov, S. A.; Holmes, R. M.

    2011-12-01

    Half of the global stock of soil organic carbon (OC) is stored in Arctic permafrost. About one third of this pool consists of so-called yedoma, organic-rich deposits that were formed during the Pleistocene. Previous studies show rapid respiration of yedoma upon thawing, with the potential release of large quantities of relict OC into the contemporary C cycle. The fluvial and coastal reactivity of this OC, however, and its fate remain unclear. Duvannyi Yar is a well-studied yedoma exposure on the banks of Kolyma River in Northeastern Siberia. It can serve as a model for the >7000 km long East Siberian Arctic coastline that is dominated by similarly exposed yedoma cliffs, and is increasingly vulnerable to erosion with climate warming-induced decreases in sea-ice, and increases in storms and wave-fetch. Permafrost thaw causes the slopes of Duvannyi Yar to retreat 3-5 m/y, producing mudstreams that drain into the Kolyma River. These streams are heavily loaded with freshly thawed yedoma sediments (ca. 650 g/L; POC ca. 10 g/L; DOC ca. 150 mg/L). Partial CO2 pressure in these streams was on average 8400 ppm (stdev 2100; n=4) whereas the Kolyma River at the stream mouth contained CO2 concentrations of ca. 900 ppm (stdev 90; n=4), suggesting substantial outgassing during transport. We performed biological oxygen demand assays in combination with a set of incubations to estimate OC lability in a range of dilutions of Duvannyi Yar water with Kolyma River and East Siberian Sea water, in combination with nutrient and enzymatic activity rate analysis to identify potential limitation processes. Our goal was to assess carbon consumption rates and the effect of different microbial communities along its transport towards the ocean. O2 loss (% after 24h) increased significantly from undiluted Kolyma water to increasingly spiked dilutions with filtered Duvannyi Yar filtered water; 0%/0.5%/1%/10%/100% dilutions showed O2 losses of 1.6%, 3.5%, 5.1%, 13% and 35%, respectively. However, C-normalized O2 losses demonstrated a different pattern. After a 24h C-loss of 5-7% for all three dilutions, the 10% dilution continued to respond up to a total of 33% lost carbon after 5 days. Enzymatic activity rates of the lignin-degrading enzyme phenoloxidase corroborated this by showing strongly elevated activity rates for the 10% Duvannyi Yar-Kolyma dilution, opposite to the 1% or 0.5% dilutions or Kolyma background. Dilutions with Kolyma water showed a slightly but consistently higher processing rate compared to dilutions of East Siberian Sea water (26 salinity). These results suggest that old OC is biologically labile upon fluvial release and its breakdown appears to be limited by availability of organic substrates. Furthermore, it appears that refractory carbon in the Kolyma is in fact being processed faster when enough Duvannyi Yar water, along with its microbes and enzymes, is added.

  20. Determination of Aspartame and Caffeine in Carbonated Beverages Utilizing Electrospray Ionization-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bergen, H. Robert, III; Benson, Linda M.; Naylor, Stephen

    2000-10-01

    Mass spectrometry has undergone considerable changes in the past decade. The advent of "soft ionization" techniques such as electrospray ionization (ESI) affords the direct analysis of very polar molecules without need for the complex inefficient derivatization procedures often required in GC-MS. These ionization techniques make possible the direct mass spectral analysis of polar nonvolatile molecules such as DNA and proteins, which previously were difficult or impossible to analyze by MS. Compounds that readily take on a charge (acids and bases) lend themselves to ESI-MS analysis, whereas compounds that do not readily accept a charge (e.g. sugars) are often not seen or are seen only as inefficient adducts (e.g., M+Na+). To gain exposure to this state-of-the-art analytical procedure, high school students utilize ESI-MS in an analysis of aspartame and caffeine. They dilute a beverage sample and inject the diluted sample into the ESI-MS. The lab is procedurally simple and the results clearly demonstrate the potential and limitations of ESI-coupled mass spectrometry. Depending upon the instructional goals, the outlined procedures can be used to quantify the content of caffeine and aspartame in beverages or to understand the capabilities of electrospray ionization.

  1. Metabolomics approach to reduce the Crabtree effect in continuous culture of Saccharomyces cerevisiae.

    PubMed

    Imura, Makoto; Iwakiri, Ryo; Bamba, Takeshi; Fukusaki, Eiichiro

    2018-04-20

    The budding yeast Saccharomyces cerevisiae is an important microorganism for fermentation and the food industry. However, during production, S. cerevisiae commonly uses the ethanol fermentation pathway for glucose utilization if excess sugar is present, even in the presence of sufficient oxygen levels. This aerobic ethanol fermentation, referred to as "the Crabtree effect" is one of the most significant reasons for low cell yield. To weaken the Crabtree effect in fed-batch and continuous culture, sugar flow should be limited. In addition, in continuous culture, the dilution rate must be reduced to avoid washing out cells. However, under such conditions, production speed might be sacrificed. It is difficult to solve this problem with the tradeoff between cell yield and production speed by using conventional tactics. However, a metabolomics approach may be an effective way to search for clues regarding metabolic modulation. Therefore, the purpose of this study was to reduce ethanol production in continuous culture of S. cerevisiae at a higher dilution rate through a metabolomics approach. We used a metabolomics analysis to identify metabolites that were drastically increased or decreased in continuous culture when the dilution rate shifted from biomass formation to ethanol fermentation. The individual addition of two of the selected metabolites, fumaric acid and malic acid, reduced ethanol production at a higher dilution rate. This result demonstrates the potential for using metabolomics approaches to identify metabolites that reduce ethanol production in continuous culture at high dilution rates. Copyright © 2018 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  2. Validation of an isotope dilution, ICP-MS method based on internal mass bias correction for the determination of trace concentrations of Hg in sediment cores.

    PubMed

    Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E

    2008-01-15

    The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.

  3. Comparative evaluation of the sensitivity of LAMP, PCR and in vitro culture methods for the diagnosis of equine piroplasmosis.

    PubMed

    Alhassan, Andy; Govind, Yadav; Tam, Nguyen Thanh; Thekisoe, Oriel M M; Yokoyama, Naoaki; Inoue, Noboru; Igarashi, Ikuo

    2007-04-01

    The sensitivity of LAMP, PCR and in vitro culture methods for the detection of Theileria equi and Babesia caballi was evaluated using tenfold serially diluted culture parasites. On day 1 post-culture, both T. equi and B. caballi parasites could only be observed at 1% parasite dilution from the in vitro culture method, whereas LAMP could detect up to 1 x 10(-3)% of both T. equi and B. caballi parasite dilutions, whilst PCR could detect 1 x 10(-3)% T. equi and 1 x 10(-1)% B. caballi parasite dilutions. On day 7 post-culture, the detection limit for T. equi and B. caballi in the in vitro culture increased up to 1 x 10(-6)%, whereas LAMP detection limit increased to 1 x 10(-10)% for both parasites, whilst the PCR detection limit increased to 1 x 10(-10)% and 1 x 10(-6)% for T. equi and B. caballi, respectively. Furthermore, LAMP and PCR amplified the T. equi DNA extracted from the organs of an experimentally infected horse. This study further validates LAMP as an alternative molecular diagnostic tool, which can be used in the diagnosis of early infections of equine piroplasmosis and together with PCR can also be used as supplementary methods during post-mortems.

  4. Quantitative Analysis by Isotopic Dilution Using Mass Spectroscopy: The Determination of Caffeine by GC-MS.

    ERIC Educational Resources Information Center

    Hill, Devon W.; And Others

    1988-01-01

    Describes a laboratory technique for quantitative analysis of caffeine by an isotopic dilution method for coupled gas chromatography-mass spectroscopy. Discusses caffeine analysis and experimental methodology. Lists sample caffeine concentrations found in common products. (MVL)

  5. An improved method for undertaking limiting dilution assays for in vitro cloning of Plasmodium falciparum parasites.

    PubMed

    Butterworth, Alice S; Robertson, Alan J; Ho, Mei-Fong; Gatton, Michelle L; McCarthy, James S; Trenholme, Katharine R

    2011-04-18

    Obtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth is an arduous and labor-intensive process. An alternative method for the detection of parasite growth in limiting dilution assays is using a commercial ELISA histidine-rich protein II (HRP2) detection kit. Detection of parasite growth was undertaken using HRP2 ELISA and compared to thick film microscopy. An HRP2 protein standard was used to determine the detection threshold of the HRP2 ELISA assay, and a HRP2 release model was used to extrapolate the amount of parasite growth required for a positive result. The HRP2 ELISA was more sensitive than microscopy for detecting parasite growth. The minimum level of HRP2 protein detection of the ELISA was 0.11 ng/ml. Modeling of HRP2 release determined that 2,116 parasites are required to complete a full erythrocytic cycle to produce sufficient HRP2 to be detected by the ELISA. Under standard culture conditions this number of parasites is likely to be reached between 8 to 14 days of culture. This method provides an accurate and simple way for the detection of parasite growth in limiting dilution assays, reducing time and resources required in traditional methods. Furthermore the method uses spent culture media instead of the parasite-infected red blood cells, enabling culture to continue. © 2011 Butterworth et al; licensee BioMed Central Ltd.

  6. Stability of purified tuberculin in high dilution

    PubMed Central

    Magnus, Knut; Guld, Johannes; Waaler, Hans; Magnusson, Mogens

    1958-01-01

    The authors have investigated the effect of storage on the potency of 5 TU dilutions (5 TU per 0.1 ml) of the purified tuberculin RT 19-21 (Statens Seruminstitut, Copenhagen). Dilutions stored at 2-4°C, 20°C and 37°C for different periods up to 18 months were compared by intradermal testing. About 900 BCG-vaccinated schoolchildren were given duplicate tests and in addition 500 tests were made in BCG-vaccinated guinea-pigs. The results showed unexpected variability. It appeared that this variability was due to unsystematic variations in potency both between dilutions prepared at different times and between ampoules of the same dilution. Because of this variability only limited conclusions could be drawn. At 2-4°C the effect of storage seemed to be very slight, the potency of the dilutions being reduced by less than 25% after 18 months. At the higher temperatures, the decrease in activity was more rapid. Nevertheless, the dilutions could be stored at room temperature (20°C) for some months without any practically significant loss of potency. PMID:13618718

  7. Liquid paraffin as new dilution medium for the analysis of high boiling point residual solvents with static headspace-gas chromatography.

    PubMed

    D'Autry, Ward; Zheng, Chao; Bugalama, John; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Wang, Bochu; Van Schepdael, Ann

    2011-07-15

    Residual solvents are volatile organic compounds which can be present in pharmaceutical substances. A generic static headspace-gas chromatography analysis method for the identification and control of residual solvents is described in the European Pharmacopoeia. Although this method is proved to be suitable for the majority of samples and residual solvents, the method may lack sensitivity for high boiling point residual solvents such as N,N-dimethylformamide, N,N-dimethylacetamide, dimethyl sulfoxide and benzyl alcohol. In this study, liquid paraffin was investigated as new dilution medium for the analysis of these residual solvents. The headspace-gas chromatography method was developed and optimized taking the official Pharmacopoeia method as a starting point. The optimized method was validated according to ICH criteria. It was found that the detection limits were below 1μg/vial for each compound, indicating a drastically increased sensitivity compared to the Pharmacopoeia method, which failed to detect the compounds at their respective limit concentrations. Linearity was evaluated based on the R(2) values, which were above 0.997 for all compounds, and inspection of residual plots. Instrument and method precision were examined by calculating the relative standard deviations (RSD) of repeated analyses within the linearity and accuracy experiments, respectively. It was found that all RSD values were below 10%. Accuracy was checked by a recovery experiment at three different levels. Mean recovery values were all in the range 95-105%. Finally, the optimized method was applied to residual DMSO analysis in four different Kollicoat(®) sample batches. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Influence of very low doses of mediators on fungal laccase activity - nonlinearity beyond imagination

    PubMed Central

    Malarczyk, Elzbieta; Kochmanska-Rdest, Janina; Jarosz-Wilkolazka, Anna

    2009-01-01

    Laccase, an enzyme responsible for aerobic transformations of natural phenolics, in industrial applications requires the presence of low-molecular substances known as mediators, which accelerate oxidation processes. However, the use of mediators is limited by their toxicity and the high costs of exploitation. The activation of extracellular laccase in growing fungal culture with highly diluted mediators, ABTS and HBT is described. Two high laccase-producing fungal strains, Trametes versicolor and Cerrena unicolor, were used in this study as a source of enzyme. Selected dilutions of the mediators significantly increased the activity of extracellular laccase during 14 days of cultivation what was distinctly visible in PAGE technique and in colorimetric tests. The same mediator dilutions increased demethylation properties of laccase, which was demonstrated during incubation of enzyme with veratric acid. It was established that the activation effect was assigned to specific dilutions of mediators. Our dose-response dilution process smoothly passes into the range of action of homeopathic dilutions and is of interest for homeopaths. PMID:19732425

  9. 40 CFR 1065.140 - Dilution for gaseous and PM constituents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... nitrogen. References in this part to “dilution air” may include any of these. For gaseous emission... test interval does not exceed the specified limits. (A) Use chemical balance equations in § 1065.655 to... balance), and set any negative values to zero. This difference is the potential mole fraction of the...

  10. Simultaneous Quantification of Free Cholesterol, Cholesteryl Esters, and Triglycerides without Ester Hydrolysis by UHPLC Separation and In-Source Collision Induced Dissociation Coupled MS/MS

    NASA Astrophysics Data System (ADS)

    Gardner, Michael S.; McWilliams, Lisa G.; Jones, Jeffrey I.; Kuklenyik, Zsuzsanna; Pirkle, James L.; Barr, John R.

    2017-08-01

    We demonstrate the application of in-source nitrogen collision-induced dissociation (CID) that eliminates the need for ester hydrolysis before simultaneous analysis of esterified cholesterol (EC) and triglycerides (TG) along with free cholesterol (FC) from human serum, using normal phase liquid chromatography (LC) coupled to atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). The analysis requires only 50 μL of 1:100 dilute serum with a high-throughput, precipitation/evaporation/extraction protocol in one pot. Known representative mixtures of EC and TG species were used as calibrators with stable isotope labeled analogs as internal standards. The APCI MS source was operated with nitrogen source gas. Reproducible in-source CID was achieved with the use of optimal cone voltage (declustering potential), generating FC, EC, and TG lipid class-specific precursor fragment ions for multiple reaction monitoring (MRM). Using a representative mixture of purified FC, CE, and TG species as calibrators, the method accuracy was assessed with analysis of five inter-laboratory standardization materials, showing -10% bias for Total-C and -3% for Total-TG. Repeated duplicate analysis of a quality control pool showed intra-day and inter-day variation of 5% and 5.8% for FC, 5.2% and 8.5% for Total-C, and 4.1% and 7.7% for Total-TG. The applicability of the method was demonstrated on 32 serum samples and corresponding lipoprotein sub-fractions collected from normolipidemic, hypercholesterolemic, hypertriglyceridemic, and hyperlipidemic donors. The results show that in-source CID coupled with isotope dilution UHPLC-MS/MS is a viable high precision approach for translational research studies where samples are substantially diluted or the amounts of archived samples are limited. [Figure not available: see fulltext.

  11. Effects of diluting medium and holding time on sperm motility analysis by CASA in ram.

    PubMed

    Mostafapor, Somayeh; Farrokhi Ardebili, Farhad

    2014-01-01

    The aim of this study was to evaluate the effects of dilution rate and holding time on various motility parameters using computer-assisted sperm analysis (CASA). The semen samples were collected from three Ghezel rams. Samples were diluted in seminal plasma (SP), phosphate-buffered saline (PBS) containing 1% bovine serum albumin (BSA) and Bioexcell. The motility parameters that computed and recorded by CASA include curvilinear velocity (VCL), straight line velocity (VSL), average path velocity (VAP), straightness (STR), linearity (LIN), amplitude of lateral head displacement (ALH), and beat cross frequency (BCF). In all diluters, there was a decrease in the average of all three parameters of sperms movement velocity as the time passed, but density of this decrease was more intensive in SP. The average of ALH between diluters indicated a significant difference, as it was more in Bioexcell in comparison with the similar amount in SP and PBS. The average of LIN in the diluted sperms in Bioexcell was less than two other diluters in all three times. The motility parameters of the diluted sperms in Bioexcell and PBS indicated an important and considerable difference with the diluted sperms in SP. According to the gained results, the Bioexcell has greater ability in preserving motility of sperm in comparison with the other diluters but as SP is considered as physiological environment for sperm. It seems that the evaluation of the motility parameters in Bioexcell and PBS cannot be an accurate and comparable evaluation with SP.

  12. Evaluating the quality of a cell counting measurement process via a dilution series experimental design.

    PubMed

    Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng

    2017-12-01

    Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.

  13. Polaron in the dilute critical Bose condensate

    NASA Astrophysics Data System (ADS)

    Pastukhov, Volodymyr

    2018-05-01

    The properties of an impurity immersed in a dilute D-dimensional Bose gas at temperatures close to its second-order phase transition point are considered. Particularly by means of the 1/N-expansion, we calculate the leading-order polaron energy and the damping rate in the limit of vanishing boson–boson interaction. It is shown that the perturbative effective mass and the quasiparticle residue diverge logarithmically in the long-length limit, signalling the non-analytic behavior of the impurity spectrum and pole-free structure of the polaron Green’s function in the infrared region, respectively.

  14. Speciation and isotope dilution analysis of gadolinium-based contrast agents in wastewater.

    PubMed

    Telgmann, Lena; Wehe, Christoph A; Birka, Marvin; Künnemeyer, Jens; Nowak, Sascha; Sperling, Michael; Karst, Uwe

    2012-11-06

    The fate of Gadolinium (Gd)-based contrast agents for magnetic resonance imaging (MRI) during sewage treatment was investigated. The total concentration of Gd in influent and effluent 2 and 24 h composite samples was determined by means of isotope dilution analysis. The balancing of Gd input and output of a sewage plant over seven days indicated that approximately 10% of the Gd is removed during treatment. Batch experiments simulating the aeration tank of a sewage treatment plant confirmed the Gd complex removal during activated sludge treatment. For speciation analysis of the Gd complexes in wastewater samples, high performance liquid chromatography (HPLC) was hyphenated to inductively coupled plasma sector field mass spectrometry (ICP-SFMS). Separation of the five predominantly used contrast agents was carried out on a new hydrophilic interaction liquid chromatography stationary phase in less than 15 min. A limit of detection (LOD) of 0.13 μg/L and a limit of quantification of 0.43 μg/L could be achieved for the Gd chelates without having to apply enrichment techniques. Speciation analysis of the 24 h composite samples revealed that 80% of the Gd complexes are present as Gd-BT-DO3A in the sampled treatment plant. The day-of-week dependent variation of the complex load followed the variation of the total Gd load, indicating a similar behavior. The analysis of sewage sludge did not prove the presence of anthropogenic Gd. However, in the effluent of the chamber filter press, which was used for sludge dewatering, two of the contrast agents and three other unknown Gd species were observed. This indicates that species transformation took place during anaerobic sludge treatment.

  15. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    ERIC Educational Resources Information Center

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  16. Fast and solvent-free quantitation of boar taint odorants in pig fat by stable isotope dilution analysis-dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry.

    PubMed

    Fischer, Jochen; Haas, Torsten; Leppert, Jan; Lammers, Peter Schulze; Horner, Gerhard; Wüst, Matthias; Boeker, Peter

    2014-09-01

    Boar taint is a specific off-odour of boar meat products, known to be caused by at least three unpleasant odorants, with very low odour thresholds. Androstenone is a boar pheromone produced in the testes, whereas skatole and indole originate from the microbial breakdown of tryptophan in the intestinal tract. A new procedure, applying stable isotope dilution analysis (SIDA) and dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry (dynHS-TD-GC/TOFMS) for the simultaneous quantitation of these boar taint compounds in pig fat was elaborated and validated in this paper. The new method is characterised by a simple and solvent-free dynamic headspace sampling. The deuterated compounds d3-androstenone, d3-skatole and d6-indole were used as internal standards to eliminate matrix effects. The method validation performed revealed low limits of detection (LOD) and quantitation (LOQ) with high accuracy and precision, thus confirming the feasibility of the new dynHS-TD-GC/TOFMS approach for routine analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Quantitative determination of four nitrofuran metabolites in meat by isotope dilution liquid chromatography-electrospray ionisation-tandem mass spectrometry.

    PubMed

    Mottier, Pascal; Khong, Seu-Ping; Gremaud, Eric; Richoz, Janique; Delatour, Thierry; Goldmann, Till; Guy, Philippe A

    2005-03-04

    A confirmatory method based on isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the low-level determination of residues of four nitrofuran veterinary drugs in meat, e.g., furazolidone, furaltadone, nitrofurantoin, and nitrofurazone. The procedure entails an acid-catalysed release of protein-bound metabolites, followed by their in situ conversion into the 2-nitrobenzaldehyde (NBA) imine-type derivatives. Liquid-liquid extraction and clean-up on a polymeric solid phase extraction cartridge are then performed before LC-MS/MS analysis by positive electrospray ionisation (ESI) applying multiple reaction monitoring of three transition reactions for each compound. Reliable quantitation is obtained by using one deuterated analogue per analyte (d4-NBA derivative) as internal standard (IS). Validation of the method in chicken meat was conducted following the European Union (EU) criteria for the analysis of veterinary drug residues in foods. The decision limits (CCalpha) were 0.11-0.21 microg/kg, and the detection capabilities (CCbeta) 0.19-0.36 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the EU. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.

  18. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Effect Of Low External Flow On Flame Spreading Over ETFE Insulated Wire Under Microgravity

    NASA Technical Reports Server (NTRS)

    Nishizawa, Katsuhiro; Fujita, Osamu; Ito, Kenichi; Kikuchi, Masao; Olson, Sandra L.; Kashiwagi, Takashi

    2003-01-01

    Fire safety is one of the most important issues for manned space missions. A likely cause of fires in spacecraft is wire insulation combustion in electrical system. Regarding the wire insulation combustion it important to know the effect of low external flow on the combustion because of the presence of ventilation flow in spacecraft. Although, there are many researches on flame spreading over solid material at low external flows under microgravity, research dealing with wire insulation is very limited. An example of wire insulation combustion in microgravity is the Space Shuttle experiments carried out by Greenberg et al. However, the number of experiments was very limited. Therefore, the effect of low flow velocity is still not clear. The authors have reported results on flame spreading over ETFE (ethylene - tetrafluoroetylene) insulated wire in a quiescent atmosphere in microgravity by 10 seconds drop tower. The authors also performed experiments of polyethylene insulated nichrom wire combustion in low flow velocity under microgravity. The results suggested that flame spread rate had maximum value in low flow velocity condition. Another interesting issue is the effect of dilution gas, especially CO2, which is used for fire extinguisher in ISS. There are some researches working on dilution gas effect on flame spreading over solid material in quiescent atmosphere in microgravity. However the research with low external flow is limited and, of course, the research discussing a relation of the appearance of maximum wire flammability in low flow velocity region with different dilution gas cannot be found yet. The present paper, therefore, investigates the effect of opposed flow with different dilution gas on flame spreading over ETFE insulated wire and change in the presence of the maximum flammability depending on the dilution gas type is discussed within the limit of microgravity time given by ground-based facility.

  20. Fast and accurate calculation of dilute quantum gas using Uehling–Uhlenbeck model equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yano, Ryosuke, E-mail: ryosuke.yano@tokiorisk.co.jp

    The Uehling–Uhlenbeck (U–U) model equation is studied for the fast and accurate calculation of a dilute quantum gas. In particular, the direct simulation Monte Carlo (DSMC) method is used to solve the U–U model equation. DSMC analysis based on the U–U model equation is expected to enable the thermalization to be accurately obtained using a small number of sample particles and the dilute quantum gas dynamics to be calculated in a practical time. Finally, the applicability of DSMC analysis based on the U–U model equation to the fast and accurate calculation of a dilute quantum gas is confirmed by calculatingmore » the viscosity coefficient of a Bose gas on the basis of the Green–Kubo expression and the shock layer of a dilute Bose gas around a cylinder.« less

  1. Theory of a microfluidic serial dilution bioreactor for growth of planktonic and biofilm populations.

    PubMed

    Hsu, Sze-Bi; Yang, Ya-Tang

    2016-04-01

    We present the theory of a microfluidic bioreactor with a two-compartment growth chamber and periodic serial dilution. In the model, coexisting planktonic and biofilm populations exchange by adsorption and detachment. The criteria for coexistence and global extinction are determined by stability analysis of the global extinction state. Stability analysis yields the operating diagram in terms of the dilution and removal ratios, constrained by the plumbing action of the bioreactor. The special case of equal uptake function and logistic growth is analytically solved and explicit growth curves are plotted. The presented theory is applicable to generic microfluidic bioreactors with discrete growth chambers and periodic dilution at discrete time points. Therefore, the theory is expected to assist the design of microfluidic devices for investigating microbial competition and microbial biofilm growth under serial dilution conditions.

  2. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  3. AN EXPERT SYSTEM FOR HYDRODYNAMIC MIXING ZONE ANAYLSIS OF CONVENTIONAL AND TOXIC SUBMERGED SINGLE PORT DISCHARGES (CORMIX1)

    EPA Science Inventory

    U.S. water quality policy includes the concept of a mixing zone, a limited area or volume of water where the initial dilution of a discharge occurs. he Cornell Mixing Zone Expert System (CORMIX1) was developed to predict the dilution and trajectory of a submerged single port disc...

  4. Regional water-quality analysis of 2,4-D and dicamba in river water using gas chromatography-isotope dilution mass spectrometry

    USGS Publications Warehouse

    Thurman, E.M.; Zimmerman, L.R.; Aga, D.S.; Gilliom, R.J.

    2001-01-01

    Gas chromatography with isotope dilution mass spectrometry (GC-MS) and enzyme-linked immunosorbent assay (ELISA) were used in regional National Water Quality Assessment studies of the herbicides, 2,4-D and dicamba, in river water across the United States. The GC-MS method involved solid-phase extraction, derivatized with deutemted 2,4-D, and analysis by selected ion monitoring. The ELISA method was applied after preconcentration with solid-phase extraction. The ELISA method was unreliable because of interference from humic substances that were also isolated by solid-phase extraction. Therefore, GC-MS was used to analyzed 80 samples from river water from 14 basins. The frequency of detection of dicamba (28%) was higher than that for 2,4-D (16%). Concentrations were higher for dicamba than for 2,4-D, ranging from less than the detection limit (<0.05 ??g/L) to 3.77 ??g/L, in spite of 5 times more annual use of 2,4-D as compared to dicamba. These results suggest that 2,4-D degrades more rapidly in the environment than dicamba.

  5. Dilute-and-shoot coupled to nanoflow liquid chromatography high resolution mass spectrometry for the determination of drugs of abuse and sport drugs in human urine.

    PubMed

    Alcántara-Durán, Jaime; Moreno-González, David; Beneito-Cambra, Miriam; García-Reyes, Juan F

    2018-05-15

    In this work, a sensitive nanoflow liquid chromatography high-resolution mass spectrometry screening method has been developed for the determination of multiclass drugs of abuse and sport drugs in human urine. 81 drugs belonging to different multiclass pharmaceuticals were targeted. The method is based on the use of a nanoLC column (75 µm × 150 mm, 3 µm particle size and 100 Å pore) with the nanospray emitter tip integrated so that dead volumes are significantly minimized. Data acquisition method included both full-scan and all ion fragmentation experiments using an Orbitrap analyser (Q-Exactive) operated in the positive ionization mode. To increase laboratory throughput, a dilute-and-shoot methodology has been tested and proposed, based solely on direct urine dilution without further sample workup. Matrix effects were evaluated, showing a negligible effect for all studied compounds when a dilution 1:50 was implemented. Despite this high-dilution factor, limits of quantification were still satisfactory, with values below 5 µg L -1 in most cases, being lower than their minimum required performance limits correspond established by the World Anti-Doping Agency. Therefore, the use of the dilute-and-shoot method with the enhanced sensitivity provided by nanoflow LC setup could be useful tool for the determination of studied compounds in drug testing, thus increasing laboratory performance, because a minimum sample treatment steps are required. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Analytical model of radiation-induced precipitation at the surface of dilute binary alloy

    NASA Astrophysics Data System (ADS)

    Pechenkin, V. A.; Stepanov, I. A.; Konobeev, Yu. V.

    2002-12-01

    Growth of precipitate layer at the foil surface of an undersaturated binary alloy under uniform irradiation is treated analytically. Analytical expressions for the layer growth rate, layer thickness limit and final component concentrations in the matrix are derived for coherent and incoherent precipitate-matrix interfaces. It is shown that the high temperature limit of radiation-induced precipitation is the same for both types of interfaces, whereas layer thickness limits are different. A parabolic law of the layer growth predicted for both types of interfaces is in agreement with experimental data on γ '-phase precipitation at the surface of Ni-Si dilute alloys under ion irradiation. Effect of sputtering on the precipitation rate and on the low temperature limit of precipitation under ion irradiation is discussed.

  7. Just add water: Accuracy of analysis of diluted human milk samples using mid-infrared spectroscopy.

    PubMed

    Smith, R W; Adamkin, D H; Farris, A; Radmacher, P G

    2017-01-01

    To determine the maximum dilution of human milk (HM) that yields reliable results for protein, fat and lactose when analyzed by mid-infrared spectroscopy. De-identified samples of frozen HM were obtained. Milk was thawed and warmed (40°C) prior to analysis. Undiluted (native) HM was analyzed by mid-infrared spectroscopy for macronutrient composition: total protein (P), fat (F), carbohydrate (C); Energy (E) was calculated from the macronutrient results. Subsequent analyses were done with 1 : 2, 1 : 3, 1 : 5 and 1 : 10 dilutions of each sample with distilled water. Additional samples were sent to a certified lab for external validation. Quantitatively, F and P showed statistically significant but clinically non-critical differences in 1 : 2 and 1 : 3 dilutions. Differences at higher dilutions were statistically significant and deviated from native values enough to render those dilutions unreliable. External validation studies also showed statistically significant but clinically unimportant differences at 1 : 2 and 1 : 3 dilutions. The Calais Human Milk Analyzer can be used with HM samples diluted 1 : 2 and 1 : 3 and return results within 5% of values from undiluted HM. At a 1 : 5 or 1 : 10 dilution, however, results vary as much as 10%, especially with P and F. At the 1 : 2 and 1 : 3 dilutions these differences appear to be insignificant in the context of nutritional management. However, the accuracy and reliability of the 1 : 5 and 1 : 10 dilutions are questionable.

  8. Single-molecule dilution and multiple displacement amplification for molecular haplotyping.

    PubMed

    Paul, Philip; Apgar, Josh

    2005-04-01

    Separate haploid analysis is frequently required for heterozygous genotyping to resolve phase ambiguity or confirm allelic sequence. We demonstrate a technique of single-molecule dilution followed by multiple strand displacement amplification to haplotype polymorphic alleles. Dilution of DNA to haploid equivalency, or a single molecule, is a simple method for separating di-allelic DNA. Strand displacement amplification is a robust method for non-specific DNA expansion that employs random hexamers and phage polymerase Phi29 for double-stranded DNA displacement and primer extension, resulting in high processivity and exceptional product length. Single-molecule dilution was followed by strand displacement amplification to expand separated alleles to microgram quantities of DNA for more efficient haplotype analysis of heterozygous genes.

  9. Identification of Key Odorants in Withering-Flavored Green Tea by Aroma Extract Dilution Analysis

    NASA Astrophysics Data System (ADS)

    Mizukami, Yuzo; Yamaguchi, Yuichi

    This research aims to identify key odorants in withering-flavored green tea. Application of the aroma extract dilution analysis using the volatile fraction of green tea and withering-flavored green tea revealed 25 and 35 odor-active peaks with the flavor dilution factors of≥4, respectively. 4-mercapto-4-methylpentan-2-one, (E)-2-nonenal, linalool, (E,Z)-2,6-nonadienal and 3-methylnonane-2,4-dione were key odorants in green tea with the flavor dilution factor of≥16. As well as these 5 odorants, 1-octen-3-one, β-damascenone, geraniol, β-ionone, (Z)-methyljasmonate, indole and coumarine contributed to the withering flavor of green tea.

  10. Heterogeneity, histological features and DNA ploidy in oral carcinoma by image-based analysis.

    PubMed

    Diwakar, N; Sperandio, M; Sherriff, M; Brown, A; Odell, E W

    2005-04-01

    Oral squamous carcinomas appear heterogeneous on DNA ploidy analysis. However, this may be partly a result of sample dilution or the detection limit of techniques. The aim of this study was to determine whether oral squamous carcinomas are heterogeneous for ploidy status using image-based ploidy analysis and to determine whether ploidy status correlates with histological parameters. Multiple samples from 42 oral squamous carcinomas were analysed for DNA ploidy using an image-based system and scored for histological parameters. 22 were uniformly aneuploid, 1 uniformly tetraploid and 3 uniformly diploid. 16 appeared heterogeneous but only 8 appeared to be genuinely heterogeneous when minor ploidy histogram peaks were taken into account. Ploidy was closely related to nuclear pleomorphism but not differentiation. Sample variation, detection limits and diagnostic criteria account for much of the ploidy heterogeneity observed. Confident diagnosis of diploid status in an oral squamous cell carcinoma requires a minimum of 5 samples.

  11. Practical and quality-control aspects of multi-element analysis with quadrupole ICP-MS with special attention to urine and whole blood.

    PubMed

    De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert

    2004-07-01

    Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.

  12. Curvature-undulation coupling as a basis for curvature sensing and generation in bilayer membranes.

    PubMed

    Bradley, Ryan P; Radhakrishnan, Ravi

    2016-08-30

    We present coarse-grained molecular dynamics simulations of the epsin N-terminal homology domain interacting with a lipid bilayer and demonstrate a rigorous theoretical formalism and analysis method for computing the induced curvature field in varying concentrations of the protein in the dilute limit. Our theory is based on the description of the height-height undulation spectrum in the presence of a curvature field. We formulated an objective function to compare the acquired undulation spectrum from the simulations to that of the theory. We recover the curvature field parameters by minimizing the objective function even in the limit where the protein-induced membrane curvature is of the same order as the amplitude due to thermal undulations. The coupling between curvature and undulations leads to significant predictions: (i) Under dilute conditions, the proteins can sense a site of spontaneous curvature at distances much larger than their size; (ii) as the density of proteins increases the coupling focuses and stabilizes the curvature field to the site of the proteins; and (iii) the mapping of the protein localization and the induction of a stable curvature is a cooperative process that can be described through a Hill function.

  13. Curvature–undulation coupling as a basis for curvature sensing and generation in bilayer membranes

    PubMed Central

    Bradley, Ryan P.; Radhakrishnan, Ravi

    2016-01-01

    We present coarse-grained molecular dynamics simulations of the epsin N-terminal homology domain interacting with a lipid bilayer and demonstrate a rigorous theoretical formalism and analysis method for computing the induced curvature field in varying concentrations of the protein in the dilute limit. Our theory is based on the description of the height–height undulation spectrum in the presence of a curvature field. We formulated an objective function to compare the acquired undulation spectrum from the simulations to that of the theory. We recover the curvature field parameters by minimizing the objective function even in the limit where the protein-induced membrane curvature is of the same order as the amplitude due to thermal undulations. The coupling between curvature and undulations leads to significant predictions: (i) Under dilute conditions, the proteins can sense a site of spontaneous curvature at distances much larger than their size; (ii) as the density of proteins increases the coupling focuses and stabilizes the curvature field to the site of the proteins; and (iii) the mapping of the protein localization and the induction of a stable curvature is a cooperative process that can be described through a Hill function. PMID:27531962

  14. Headspace solid phase microextraction and gas chromatography-olfactometry dilution analysis of young and aged Chinese "Yanghe Daqu" liquors.

    PubMed

    Fan, Wenlai; Qian, Michael C

    2005-10-05

    The aroma compounds of young and aged Chinese "Yanghe Daqu" liquor samples were extracted by solid phase microextraction (SPME) and analyzed by gas chromatography (GC)-olfactometry dilution analysis. The original liquor samples were diluted with deionized water to give a final alcohol content of 14% (v/v). The samples were stepwise diluted (1:1) with 14% (by volume) ethanol-water solution and then extracted by headspace SPME. The samples were preequilibrated at 50 degrees C for 15 min and extracted with stirring at the same temperature for 30 min prior to injection into GC. The aroma compounds were identified by both GC-MS and GC-olfactometry using DB-Wax and DB-5 columns. The results suggested that esters were the major contributors to Yanghe Daqu liquor aroma. Ethyl hexanoate, ethyl butanoate, and ethyl pentanoate had very high flavor dilution values in both young and aged liquors (FD > 8192). Methyl hexanoate, ethyl heptanoate, ethyl benzoate, and butyl hexanoate could also be very important because of their high flavor dilution values (FD > or = 256). Moreover, two acetals, 1,1-diethoxyethane and 1,1-diethoxy-3-methylbutane, also were shown high flavor dilution values in Yanghe Daqu liquors (FD > or = 256). Other aroma compounds having moderate flavor dilution values included acetaldehyde, 3-methylbutanol, and 2-pentanol (FD > or = 32). Comparing young and aged liquors, the aroma profiles were similar, but the aroma compounds in the aged sample had higher flavor dilution values than in the young ones.

  15. On-chip dilution in nanoliter droplets.

    PubMed

    Thakur, Raviraj; Amin, Ahmed M; Wereley, Steve

    2015-09-07

    Droplet microfluidics is enabling reactions at nano- and picoliter scale, resulting in faster and cheaper biological and chemical analyses. However, varying concentrations of samples on a drop-to-drop basis is still a challenging task in droplet microfluidics, primarily limited due to lack of control over individual droplets. In this paper, we report an on-chip microfluidic droplet dilution strategy using three-valve peristaltic pumps.

  16. Use of a Novel Embryonic Mammary Stem Cell Gene Signature to Improve Human Breast Cancer Diagnostics and Therapeutic Decision Making

    DTIC Science & Technology

    2013-10-01

    the fMaSC population into its component cell types. Based on in vitro sphere formation and in vivo limiting dilution transplantation functional...vivo transplantation . This approach will not only enable us to identify biomarkers useful for prospectively identifying fMaSCs, but should also...capture wells containing candidate fMaSC cells. green=live (Calcein-AM), red= dead (Ethidium Bromide). (B) RT-PCR analysis of prepared cDNA libraries

  17. Doping control analysis of 46 polar drugs in horse plasma and urine using a 'dilute-and-shoot' ultra high performance liquid chromatography-high resolution mass spectrometry approach.

    PubMed

    Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M

    2016-06-17

    The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    NASA Astrophysics Data System (ADS)

    Stosnach, Hagen; Mages, Margarete

    2009-04-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  19. Neuronal metabolomics by ion mobility mass spectrometry: cocaine effects on glucose and selected biogenic amine metabolites in the frontal cortex, striatum, and thalamus of the rat.

    PubMed

    Kaplan, Kimberly A; Chiu, Veronica M; Lukus, Peter A; Zhang, Xing; Siems, William F; Schenk, James O; Hill, Herbert H

    2013-02-01

    We report results of studies of global and targeted neuronal metabolomes by ambient pressure ion mobility mass spectrometry. The rat frontal cortex, striatum, and thalamus were sampled from control nontreated rats and those treated with acute cocaine or pargyline. Quantitative evaluations were made by standard additions or isotopic dilution. The mass detection limit was ~100 pmol varying with the analyte. Targeted metabolites of dopamine, serotonin, and glucose followed the rank order of distribution expected between the anatomical areas. Data was evaluated by principal component analysis on 764 common metabolites (identified by m/z and reduced mobility). Differences between anatomical areas and treatment groups were observed for 53 % of these metabolites using principal component analysis. Global and targeted metabolic differences were observed between the three anatomical areas with contralateral differences between some areas. Following drug treatments, global and targeted metabolomes were found to shift relative to controls and still maintained anatomical differences. Pargyline reduced 3,4-dihydroxyphenylacetic acid below detection limits, and 5-HIAA varied between anatomical regions. Notable findings were: (1) global metabolomes were different between anatomical areas and were altered by acute cocaine providing a broad but targeted window of discovery for metabolic changes produced by drugs of abuse; (2) quantitative analysis was demonstrated using isotope dilution and standard addition; (3) cocaine changed glucose and biogenic amine metabolism in the anatomical areas tested; and (4) the largest effect of cocaine was on the glycolysis metabolome in the thalamus confirming inferences from previous positron emission tomography studies using 2-deoxyglucose.

  20. 'Dilute-and-shoot' triple parallel mass spectrometry method for analysis of vitamin D and triacylglycerols in dietary supplements

    USDA-ARS?s Scientific Manuscript database

    A method is demonstrated for analysis of vitamin D-fortified dietary supplements that eliminates virtually all chemical pretreatment prior to analysis, and is referred to as a ‘dilute and shoot’ method. Three mass spectrometers, in parallel, plus a UV detector, an evaporative light scattering detec...

  1. 40 CFR 449.11 - New source performance standards (NSPS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... percent of available ADF. (2) Numerical effluent limitation. The new source must achieve the performance... the numeric limitations for ammonia in Table III, prior to any dilution or commingling with any non...

  2. 40 CFR 449.11 - New source performance standards (NSPS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... percent of available ADF. (2) Numerical effluent limitation. The new source must achieve the performance... the numeric limitations for ammonia in Table III, prior to any dilution or commingling with any non...

  3. 40 CFR 449.11 - New source performance standards (NSPS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... percent of available ADF. (2) Numerical effluent limitation. The new source must achieve the performance... the numeric limitations for ammonia in Table III, prior to any dilution or commingling with any non...

  4. Cluster Dynamics Modeling with Bubble Nucleation, Growth and Coalescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Almeida, Valmor F.; Blondel, Sophie; Bernholdt, David E.

    The topic of this communication pertains to defect formation in irradiated solids such as plasma-facing tungsten submitted to helium implantation in fusion reactor com- ponents, and nuclear fuel (metal and oxides) submitted to volatile ssion product generation in nuclear reactors. The purpose of this progress report is to describe ef- forts towards addressing the prediction of long-time evolution of defects via continuum cluster dynamics simulation. The di culties are twofold. First, realistic, long-time dynamics in reactor conditions leads to a non-dilute di usion regime which is not accommodated by the prevailing dilute, stressless cluster dynamics theory. Second, long-time dynamics callsmore » for a large set of species (ideally an in nite set) to capture all possible emerging defects, and this represents a computational bottleneck. Extensions beyond the dilute limit is a signi cant undertaking since no model has been advanced to extend cluster dynamics to non-dilute, deformable conditions. Here our proposed approach to model the non-dilute limit is to monitor the appearance of a spatially localized void volume fraction in the solid matrix with a bell shape pro le and insert an explicit geometrical bubble onto the support of the bell function. The newly cre- ated internal moving boundary provides the means to account for the interfacial ux of mobile species into the bubble, and the growth of bubbles allows for coalescence phenomena which captures highly non-dilute interactions. We present a preliminary interfacial kinematic model with associated interfacial di usion transport to follow the evolution of the bubble in any number of spatial dimensions and any number of bubbles, which can be further extended to include a deformation theory. Finally we comment on a computational front-tracking method to be used in conjunction with conventional cluster dynamics simulations in the non-dilute model proposed.« less

  5. Analysis of hydrazine in drinking water by isotope dilution gas chromatography/tandem mass spectrometry with derivatization and liquid-liquid extraction.

    PubMed

    Davis, William E; Li, Yongtao

    2008-07-15

    A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.

  6. Levels of cyclic-2,3-diphosphoglycerate in Methanobacterium thermoautotrophicum during phosphate limitation.

    PubMed Central

    Seely, R J; Fahrney, D E

    1984-01-01

    Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At this dilution rate, the Pi concentration in the culture was 4 microM. An H2-limited steady state was achieved with 400 microM Pi in the inflowing medium (67 microM in the culture). The cyclic DPG content of these cells was 72 to 74 mumol/g, about one-third the amount in batch-grown cells. The specific growth rate accelerated immediately to 0.36 h-1 (1.9-h doubling time) under washout conditions at high dilution rate. The cellular content of cyclic DPG declined over a 2-h period, and then increased rapidly as the Pi level in the medium approached 200 microM. Expansion of the cyclic DPG pool coincided with a marked increase in Pi assimilation. These results indicated that M. thermoautotrophicum accumulated cyclic DPG only when Pi and H2 were readily available. PMID:6480564

  7. Levels of cyclic-2,3-diphosphoglycerate in Methanobacterium thermoautotrophicum during phosphate limitation.

    PubMed

    Seely, R J; Fahrney, D E

    1984-10-01

    Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At this dilution rate, the Pi concentration in the culture was 4 microM. An H2-limited steady state was achieved with 400 microM Pi in the inflowing medium (67 microM in the culture). The cyclic DPG content of these cells was 72 to 74 mumol/g, about one-third the amount in batch-grown cells. The specific growth rate accelerated immediately to 0.36 h-1 (1.9-h doubling time) under washout conditions at high dilution rate. The cellular content of cyclic DPG declined over a 2-h period, and then increased rapidly as the Pi level in the medium approached 200 microM. Expansion of the cyclic DPG pool coincided with a marked increase in Pi assimilation. These results indicated that M. thermoautotrophicum accumulated cyclic DPG only when Pi and H2 were readily available.

  8. Validation of dilution of plasma samples with phosphate buffered saline to eliminate the problem of small volumes associated with children infected with HIV-1 for viral load testing using Cobas AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0).

    PubMed

    Mine, Madisa; Nkoane, Tapologo; Sebetso, Gaseene; Sakyi, Bright; Makhaola, Kgomotso; Gaolathe, Tendani

    2013-12-01

    The sample requirement of 1 mL for the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0) limits its utility in measuring plasma HIV-1 RNA levels for small volume samples from children infected with HIV-1. Viral load monitoring is the standard of care for HIV-1-infected patients on antiretroviral therapy in Botswana. The study aimed to validate the dilution of small volume samples with phosphate buffered saline (1× PBS) when quantifying HIV-1 RNA in patient plasma. HIV RNA concentrations were determined in undiluted and diluted pairs of samples comprising panels of quality assessment standards (n=52) as well as patient samples (n=325). There was strong correlation (R(2)) of 0.98 and 0.95 within the dynamic range of the CAP CTM HIV v2.0 test between undiluted and diluted samples from quality assessment standards and patients, respectively. The difference between viral load measurements of diluted and undiluted pairs of quality assessment standards and patient samples using the Altman-Bland test showed that the 95% limits of agreement were between -0.40 Log 10 and 0.49 Log 10. This difference was within the 0.5 Log 10 which is generally considered as normal assay variation of plasma RNA levels. Dilution of samples with 1× PBS produced comparable viral load measurements to undiluted samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Dielectric dispersion studies of some potentised homeopathic medicines reveal structured vehicle.

    PubMed

    Mahata, C R

    2013-10-01

    Avogadro's Number gives 12c as the limit beyond which no original substance can be present in a highly diluted and succcussed (potentised) homeopathic medicine, implying that chemically such dilutions consist of nothing but the vehicle. But there is evidence that living systems react to homeopathic medicines diluted even above 12c. To explain how such medicines differ from another I hypothesise that altered structure may cause the difference, such as that between diamond and amorphous carbon. Some scientists have argued that dilution followed by succussion may lead to altered structural arrangement of water molecules. This concept may be termed 'Induced Molecular Structure'. Dielectric dispersion studies were conducted in a broad range with potencies below and above the Avogadro limit by taking 6c and 30c potencies of Graphites and Cuprum Metallicum in liquid form. Measurements were made with an Anomalous Dielectric Dispersion Detector (A3D), an instrument developed by the author. Experiments were carried out in a frequency range of 100 kHz to 50 MHz. Shifting of resonance frequencies as a function of medicine and potency, with potencies below and above the Avogadro limit, was observed. The range of resonance frequencies suggest that the phenomenon might originate from oscillation of dipoles caused by electric field in variously structured and polarised water. Also, there is reasonable evidence that frequencies change with materials and potency. Copyright © 2013 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  10. One-Shot Coherence Dilution.

    PubMed

    Zhao, Qi; Liu, Yunchao; Yuan, Xiao; Chitambar, Eric; Ma, Xiongfeng

    2018-02-16

    Manipulation and quantification of quantum resources are fundamental problems in quantum physics. In the asymptotic limit, coherence distillation and dilution have been proposed by manipulating infinite identical copies of states. In the nonasymptotic setting, finite data-size effects emerge, and the practically relevant problem of coherence manipulation using finite resources has been left open. This Letter establishes the one-shot theory of coherence dilution, which involves converting maximally coherent states into an arbitrary quantum state using maximally incoherent operations, dephasing-covariant incoherent operations, incoherent operations, or strictly incoherent operations. We introduce several coherence monotones with concrete operational interpretations that estimate the one-shot coherence cost-the minimum amount of maximally coherent states needed for faithful coherence dilution. Furthermore, we derive the asymptotic coherence dilution results with maximally incoherent operations, incoherent operations, and strictly incoherent operations as special cases. Our result can be applied in the analyses of quantum information processing tasks that exploit coherence as resources, such as quantum key distribution and random number generation.

  11. Microstructures and mechanical properties of bonding layers between low carbon steel and alloy 625 processed by gas tungsten arc welding

    NASA Astrophysics Data System (ADS)

    Lou, Shuai; Lee, Seul Bi; Nam, Dae-Geun; Choi, Yoon Suk

    2017-11-01

    A filler metal wire, Alloy 625, was cladded on a plate of a low carbon streel, SS400, by gas tungsten arc welding, and the morphology of the weld bead and resulting dilution ratio were investigated under different welding parameter values (the input current, weld speed and wire feed speed). The wire feed speed was found to be most influential in controlling the dilution ratio of the weld bead, and seemed to limit the influence of other welding parameters. Two extreme welding conditions (with the minimum and maximum dilution ratios) were identified, and the corresponding microstructures, hardness and tensile properties near the bond line were compared between the two cases. The weld bead with the minimum dilution ratio showed superior hardness and tensile properties, while the formation lath martensite (due to relatively fast cooling) affected mechanical properties in the heat affected zone of the base metal with the maximum dilution ratio.

  12. One-Shot Coherence Dilution

    NASA Astrophysics Data System (ADS)

    Zhao, Qi; Liu, Yunchao; Yuan, Xiao; Chitambar, Eric; Ma, Xiongfeng

    2018-02-01

    Manipulation and quantification of quantum resources are fundamental problems in quantum physics. In the asymptotic limit, coherence distillation and dilution have been proposed by manipulating infinite identical copies of states. In the nonasymptotic setting, finite data-size effects emerge, and the practically relevant problem of coherence manipulation using finite resources has been left open. This Letter establishes the one-shot theory of coherence dilution, which involves converting maximally coherent states into an arbitrary quantum state using maximally incoherent operations, dephasing-covariant incoherent operations, incoherent operations, or strictly incoherent operations. We introduce several coherence monotones with concrete operational interpretations that estimate the one-shot coherence cost—the minimum amount of maximally coherent states needed for faithful coherence dilution. Furthermore, we derive the asymptotic coherence dilution results with maximally incoherent operations, incoherent operations, and strictly incoherent operations as special cases. Our result can be applied in the analyses of quantum information processing tasks that exploit coherence as resources, such as quantum key distribution and random number generation.

  13. Liquid chromatography/electrospray ionization/isotopic dilution mass spectrometry analysis of n-(phosphonomethyl) glycine and mass spectrometry analysis of aminomethyl phosphonic acid in environmental water and vegetation matrixes.

    PubMed

    Grey, L; Nguyen, B; Yang, P

    2001-01-01

    A liquid chromatography/electrospray/mass spectrometry (LC/ES/MS) method was developed for the analysis of glyphosate (n-phosphonomethyl glycine) and its metabolite, aminomethyl phosphonic acid (AMPA) using isotope-labelled glyphosate as a method surrogate. Optimized parameters were achieved to derivatize glyphosate and AMPA using 9-fluorenylmethyl chloroformate (FMOC-Cl) in borate buffer prior to a reversed-phase LC analysis. Method spike recovery data obtained using laboratory and real world sample matrixes indicated an excellent correlation between the recovery of the native and isotope-labelled glyphosate. Hence, the first performance-based, isotope dilution MS method with superior precision, accuracy, and data quality was developed for the analysis of glyphosate. There was, however, no observable correlation between the isotope-labelled glyphosate and AMPA. Thus, the use of this procedure for the accurate analysis of AMPA was not supported. Method detection limits established using standard U.S. Environmental Protection Agency protocol were 0.06 and 0.30 microg/L, respectively, for glyphosate and AMPA in water matrixes and 0.11 and 0.53 microg/g, respectively, in vegetation matrixes. Problems, solutions, and the method performance data related to the analysis of chlorine-treated drinking water samples are discussed. Applying this method to other environmental matrixes, e.g., soil, with minimum modifications is possible, assuring accurate, multimedia studies of glyphosate concentration in the environment and the delivery of useful multimedia information for regulatory applications.

  14. Whole genome amplification and real-time PCR in forensic casework

    PubMed Central

    Giardina, Emiliano; Pietrangeli, Ilenia; Martone, Claudia; Zampatti, Stefania; Marsala, Patrizio; Gabriele, Luciano; Ricci, Omero; Solla, Gianluca; Asili, Paola; Arcudi, Giovanni; Spinella, Aldo; Novelli, Giuseppe

    2009-01-01

    Background WGA (Whole Genome Amplification) in forensic genetics can eliminate the technical limitations arising from low amounts of genomic DNA (gDNA). However, it has not been used to date because any amplification bias generated may complicate the interpretation of results. Our aim in this paper was to assess the applicability of MDA to forensic SNP genotyping by performing a comparative analysis of genomic and amplified DNA samples. A 26-SNPs TaqMan panel specifically designed for low copy number (LCN) and/or severely degraded genomic DNA was typed on 100 genomic as well as amplified DNA samples. Results Aliquots containing 1, 0.1 and 0.01 ng each of 100 DNA samples were typed for a 26-SNPs panel. Similar aliquots of the same DNA samples underwent multiple displacement amplification (MDA) before being typed for the same panel. Genomic DNA samples showed 0% PCR failure rate for all three dilutions, whilst the PCR failure rate of the amplified DNA samples was 0% for the 1 ng and 0.1 ng dilutions and 0.077% for the 0.01 ng dilution. The genotyping results of both the amplified and genomic DNA samples were also compared with reference genotypes of the same samples obtained by direct sequencing. The genomic DNA samples showed genotype concordance rates of 100% for all three dilutions while the concordance rates of the amplified DNA samples were 100% for the 1 ng and 0.1 ng dilutions and 99.923% for the 0.01 ng dilution. Moreover, ten artificially-degraded DNA samples, which gave no results when analyzed by current forensic methods, were also amplified by MDA and genotyped with 100% concordance. Conclusion We investigated the suitability of MDA material for forensic SNP typing. Comparative analysis of amplified and genomic DNA samples showed that a large number of SNPs could be accurately typed starting from just 0.01 ng of template. We found that the MDA genotyping call and accuracy rates were only slightly lower than those for genomic DNA. Indeed, when 10 pg of input DNA was used in MDA, we obtained 99.923% concordance, indicating a genotyping error rate of 1/1299 (7.7 × 10-4). This is quite similar to the genotyping error rate of STRs used in current forensic analysis. Such efficiency and accuracy of SNP typing of amplified DNA suggest that MDA can also generate large amounts of genome-equivalent DNA from a minimal amount of input DNA. These results show for the first time that MDA material is suitable for SNP-based forensic protocols and in general when samples fail to give interpretable STR results. PMID:19366436

  15. Stroop Dilution Revisited: Evidence for Domain-Specific, Limited-Capacity Processing

    ERIC Educational Resources Information Center

    Roberts, Martha Anne; Besner, Derek

    2005-01-01

    Nine experiments show that in the context of Stroop dilution the extent to which flanking distractors are processed depends on the nature of the material at fixation. A Stroop effect is eliminated if a word or a nonword is colored and appears at fixation and the color word appears as a flanker. A Stroop effect is observed when the color carrier at…

  16. Determination of six sulfonamide antibiotics, two metabolites and trimethoprim in wastewater by isotope dilution liquid chromatography/tandem mass spectrometry.

    PubMed

    Le-Minh, Nhat; Stuetz, Richard M; Khan, Stuart J

    2012-01-30

    A highly sensitive method for the analysis of six sulfonamide antibiotics (sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine and sulfamethoxazole), two sulfonamide metabolites (N(4)-acetyl sulfamethazine and N(4)-acetyl sulfamethoxazole) and the commonly co-applied antibiotic trimethoprim was developed for the analysis of complex wastewater samples. The method involves solid phase extraction of filtered wastewater samples followed by liquid chromatography-tandem mass spectral detection. Method detection limits were shown to be matrix-dependent but ranged between 0.2 and 0.4 ng/mL for ultrapure water, 0.4 and 0.7 ng/mL for tap water, 1.4 and 5.9 ng/mL for a laboratory-scale membrane bioreactor (MBR) mixed liquor, 0.7 and 1.7 ng/mL for biologically treated effluent and 0.5 and 1.5 ng/g dry weight for MBR activated sludge. An investigation of analytical matrix effects was undertaken, demonstrating the significant and largely unpredictable nature of signal suppression observed for variably complex matrices compared to an ultrapure water matrix. The results demonstrate the importance of accounting for such matrix effects for accurate quantitation, as done in the presented method by isotope dilution. Comprehensive validation of calibration linearity, reproducibility, extraction recovery, limits of detection and quantification are also presented. Finally, wastewater samples from a variety of treatment stages in a full-scale wastewater treatment plant were analysed to illustrate the effectiveness of the method. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Direct determination of fatty acid esters of 3-chloro-1, 2-propanediol in edible vegetable oils by isotope dilution - ultra high performance liquid chromatography - triple quadrupole mass spectrometry.

    PubMed

    Li, Heli; Chen, Dawei; Miao, Hong; Zhao, Yunfeng; Shen, Jianzhong; Wu, Yongning

    2015-09-04

    A selective and sensitive ultra-high performance liquid chromatography - triple quadrupole mass spectrometry (UHPLC-MS/MS) method coupled with matrix solid phase dispersion (MSPD) extraction was developed for the direct determination of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD esters) in edible vegetable oils. The method integrated the isotope dilution technique, MSPD extraction and UHPLC - MS/MS analysis with multi-reaction monitoring mode (MRM). Matrix-matched calibration curves showed good linearity within the range of 0.01-10mgL(-1) with the correlation coefficient not less than 0.999. Limits of detection (LODs) and limit of quantification (LOQs) of the 3-MCPD esters fell into the range of 0.0001-0.02mgkg(-1) and 0.0004-0.05mgkg(-1), respectively. The recoveries for the spiked extra virgin olive oils ranged from 94.4% to 108.3%, with the relative standard deviations (RSD) ranging from 0.6% to 10.5%. The method was applied for the oil sample (T2642) of the official Food Analysis Performance Assessment Scheme (FAPAS) in 2014 and other real samples from supermarket, and the results showed that the present method was comparative to the gas chromatography-mass spectrometry (GC-MS) method based on the improved German Society for Fat Science (DGF) standard method C-III 18 (09) except for palm oil. Copyright © 2015. Published by Elsevier B.V.

  18. Biodiversity inhibits parasites: Broad evidence for the dilution effect.

    PubMed

    Civitello, David J; Cohen, Jeremy; Fatima, Hiba; Halstead, Neal T; Liriano, Josue; McMahon, Taegan A; Ortega, C Nicole; Sauer, Erin Louise; Sehgal, Tanya; Young, Suzanne; Rohr, Jason R

    2015-07-14

    Infectious diseases of humans, wildlife, and domesticated species are increasing worldwide, driving the need to understand the mechanisms that shape outbreaks. Simultaneously, human activities are drastically reducing biodiversity. These concurrent patterns have prompted repeated suggestions that biodiversity and disease are linked. For example, the dilution effect hypothesis posits that these patterns are causally related; diverse host communities inhibit the spread of parasites via several mechanisms, such as by regulating populations of susceptible hosts or interfering with parasite transmission. However, the generality of the dilution effect hypothesis remains controversial, especially for zoonotic diseases of humans. Here we provide broad evidence that host diversity inhibits parasite abundance using a meta-analysis of 202 effect sizes on 61 parasite species. The magnitude of these effects was independent of host density, study design, and type and specialization of parasites, indicating that dilution was robust across all ecological contexts examined. However, the magnitude of dilution was more closely related to the frequency, rather than density, of focal host species. Importantly, observational studies overwhelmingly documented dilution effects, and there was also significant evidence for dilution effects of zoonotic parasites of humans. Thus, dilution effects occur commonly in nature, and they may modulate human disease risk. A second analysis identified similar effects of diversity in plant-herbivore systems. Thus, although there can be exceptions, our results indicate that biodiversity generally decreases parasitism and herbivory. Consequently, anthropogenic declines in biodiversity could increase human and wildlife diseases and decrease crop and forest production.

  19. Quantitation of Rotundone in Grapefruit (Citrus paradisi) Peel and Juice by Stable Isotope Dilution Assay.

    PubMed

    Nakanishi, Akira; Fukushima, Yusuke; Miyazawa, Norio; Yoshikawa, Keisuke; Maeda, Tomoko; Kurobayashi, Yoshiko

    2017-06-21

    Aroma extract dilution analyses of the aromas of peels and juices of white and pink grapefruits revealed that rotundone, responsible for peppery, spicy, and woody odors, was detected for the first time at high flavor dilution factors of 256-1024. In both juices, rotundone was detected at the highest flavor dilution factor of 1024. Rotundone in grapefruits was quantitated by a stable isotope dilution assay with a newly synthesized deuterium-labeled internal standard, rotundone-d 2,3 : its levels were 2180 and 1920 ng/kg in white and pink grapefruit peels and 29.6 and 49.8 ng/kg in white and pink grapefruit juices, respectively. On the basis of these results, sensory analysis was performed to assess the effects of rotundone on a white grapefruit juice aroma reconstitute. This sensory analysis revealed that rotundone does not impart a woody odor or affect any of the existing attributes, but increases various attributes, thus confirming that rotundone is indispensable for the aroma of grapefruit juice.

  20. Determination of buildup and dilution of wastewater effluent in shellfish growing waters through a modified application of super-position.

    PubMed

    Goblick, Gregory N; Ao, Yaping; Anbarchian, Julie M; Calci, Kevin R

    2017-02-15

    Since 1925, dilution analysis has been used to minimize pathogenic impacts to bivalve molluscan shellfish growing areas from treated wastewater effluent in the National Shellfish Sanitation Program (NSSP). For over twenty five years, the U.S. Food and Drug Administration (FDA) has recommended a minimum of 1000:1 dilution of effluent within prohibited closure zones established around wastewater treatment plant (WWTP) discharges. During May 2010, using recent technologies, a hydrographic dye study was conducted in conjunction with a pathogen bioaccumulation study in shellfish adjacent to a WWTP discharge in Yarmouth, ME. For the first time an improved method of the super-position principle was used to determine the buildup of dye tagged sewage effluent and steady state dilution in tidal waters. Results of the improved method of dilution analysis illustrate an economical, reliable and more accurate and manageable approach for estimating the buildup and steady state pollutant conditions in coastal and estuarine waters. Published by Elsevier Ltd.

  1. A helium-3/helium-4 dilution cryocooler for operation in zero gravity

    NASA Technical Reports Server (NTRS)

    Hendricks, John B.

    1988-01-01

    This research effort covered the development of He-3/He-4 dilution cryocooler cycles for use in zero gravity. The dilution cryocooler is currently the method of choice for producing temperatures below 0.3 Kelvin in the laboratory. However, the current dilution cryocooler depends on gravity for their operation, so some modification is required for zero gravity operation. In this effort, we have demonstrated, by analysis, that the zero gravity dilution cryocooler is feasible. We have developed a cycle that uses He-3 circulation, and an alternate cycle that uses superfluid He-4 circulation. The key elements of both cycles were demonstrated experimentally. The development of a true 'zero-gravity' dilution cryocooler is now possible, and should be undertaken in a follow-on effort.

  2. The CETAC ADX-500 Autodiluter System: A Study of Dilution Performance with the ELAN 6000 ICP-MS and ELAN Software

    USGS Publications Warehouse

    May, T.W.; Wiedmeyer, Ray H.

    1998-01-01

    The CETAC ADX-500 autodiluter system was tested with ELAN?? v 2.1 software and the ELAN 6000 ICP-MS instrument to determine on-line automated dilution performance during analysis of standard solutions containing nine analytes representative of the mass spectral range (mass 9 to mass 238). Two or more dilution schemes were tested for each of 5 test tube designs. Dilution performance was determined by comparison of analyte concentration means of diluted and non-diluted standards. Accurate dilutions resulted with one syringe pump addition of diluent in small diameter round-bottomed (13 mm OD) or conical-tipped (18 mm OD) tubes and one or more syringe pump additions in large diameter (28 mm OD) conical-tipped tubes. Inadequate dilution mixing which produced high analyte concentration means was observed for all dilutions conducted in flat-bottomed tubes, and for dilutions requiring multiple syringe additions of diluent in small diameter round-bottomed and conical tipped tubes. Effective mixing of diluted solutions was found to depend largely upon tube diameter and liquid depth: smaller tube diameters and greater liquid depth resulted in ineffective mixing, whereas greater tube diameter and shallower liquid depth facilitated effective mixing. Two design changes for the autodiluter were suggested that would allow effective mixing to occur using any dilution scheme and tube design.

  3. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g(-1) levels.

    PubMed

    Boulyga, Sergei F; Tibi, Markus; Heumann, Klaus G

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.

  4. Strategies and limitations for fluorescence detection of XAFS at high flux beamlines

    DOE PAGES

    Heald, Steve M.

    2015-02-17

    The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 10 13 photons -1. Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detectormore » is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 10 7 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved.« less

  5. Strategies and limitations for fluorescence detection of XAFS at high flux beamlines

    PubMed Central

    Heald, Steve M.

    2015-01-01

    The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 1013 photons s−1. Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detector is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 107 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved. PMID:25723945

  6. Ultimate Temperature of Pulse Tube Cryocoolers

    NASA Technical Reports Server (NTRS)

    Kittel, Peter

    2009-01-01

    An ideal pulse tube cryocooler using an ideal gas can operate at any temperature. This is not true for real gases. The enthalpy flow resulting from the real gas effects of He-3, He-4, and their mixtures in ideal pulse tube cryocoolers puts limits on the operating temperature of pulse tube cryocoolers. The discussion of these effects follows a previous description of the real gas effects in ideal pulse tube cryocoolers and makes use of models of the thermophysical properties of He-3 and He-4. Published data is used to extend the analysis to mixtures of He-3 and He-4. The analysis was done for pressures below 2 MPa and temperatures below 2.5 K. Both gases and their mixtures show low temperature limits for pulse tube cryocoolers. These limits are in the 0.5-2.2 K range and depend on pressure and mixture. In some circumstances, even lower temperatures may be possible. Pulse tube cryocoolers using the two-fluid properties of dilute 3He in superfluid He-4 appear to have no limit.

  7. Ultimate Temperature of Pulse Tube Cryocoolers

    NASA Technical Reports Server (NTRS)

    Kittel, Peter

    2009-01-01

    An ideal pulse tube cryocooler using an ideal gas can operate at any temperature. This is not true for real gases. The enthalpy flow resulting from the real gas effects of 3He, 4He, and their mixtures in ideal pulse tube cryocoolers puts limits on the operating temperature of pulse tube cryocoolers. The discussion of these effects follows a previous description of the real gas effects in ideal pulse tube cryocoolers and makes use of models of the thermophysical properties of 3He and 4He. Published data is used to extend the analysis to mixtures of 3He and 4He. The analysis was done for pressures below 2 MPa and temperatures below 2.5 K. Both gases and their mixtures show low temperature limits for pulse tube cryocoolers. These limits are in the 0.5-2.2 K range and depend on pressure and mixture. In some circumstances, even lower temperatures may be possible. Pulse tube cryocoolers using the ha-fluid properties of dilute 3He in superfluid 4He appear to have no limit.

  8. CONVECTION IN CONDENSIBLE-RICH ATMOSPHERES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, F.; Pierrehumbert, R. T., E-mail: fding@uchicago.edu

    2016-05-01

    Condensible substances are nearly ubiquitous in planetary atmospheres. For the most familiar case—water vapor in Earth’s present climate—the condensible gas is dilute, in the sense that its concentration is everywhere small relative to the noncondensible background gases. A wide variety of important planetary climate problems involve nondilute condensible substances. These include planets near or undergoing a water vapor runaway and planets near the outer edge of the conventional habitable zone, for which CO{sub 2} is the condensible. Standard representations of convection in climate models rely on several approximations appropriate only to the dilute limit, while nondilute convection differs in fundamentalmore » ways from dilute convection. In this paper, a simple parameterization of convection valid in the nondilute as well as dilute limits is derived and used to discuss the basic character of nondilute convection. The energy conservation properties of the scheme are discussed in detail and are verified in radiative-convective simulations. As a further illustration of the behavior of the scheme, results for a runaway greenhouse atmosphere for both steady instellation and seasonally varying instellation corresponding to a highly eccentric orbit are presented. The latter case illustrates that the high thermal inertia associated with latent heat in nondilute atmospheres can damp out the effects of even extreme seasonal forcing.« less

  9. Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.

    PubMed

    King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude

    2006-09-01

    Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.

  10. Introducing AAA-MS, a rapid and sensitive method for amino acid analysis using isotope dilution and high-resolution mass spectrometry.

    PubMed

    Louwagie, Mathilde; Kieffer-Jaquinod, Sylvie; Dupierris, Véronique; Couté, Yohann; Bruley, Christophe; Garin, Jérôme; Dupuis, Alain; Jaquinod, Michel; Brun, Virginie

    2012-07-06

    Accurate quantification of pure peptides and proteins is essential for biotechnology, clinical chemistry, proteomics, and systems biology. The reference method to quantify peptides and proteins is amino acid analysis (AAA). This consists of an acidic hydrolysis followed by chromatographic separation and spectrophotometric detection of amino acids. Although widely used, this method displays some limitations, in particular the need for large amounts of starting material. Driven by the need to quantify isotope-dilution standards used for absolute quantitative proteomics, particularly stable isotope-labeled (SIL) peptides and PSAQ proteins, we developed a new AAA assay (AAA-MS). This method requires neither derivatization nor chromatographic separation of amino acids. It is based on rapid microwave-assisted acidic hydrolysis followed by high-resolution mass spectrometry analysis of amino acids. Quantification is performed by comparing MS signals from labeled amino acids (SIL peptide- and PSAQ-derived) with those of unlabeled amino acids originating from co-hydrolyzed NIST standard reference materials. For both SIL peptides and PSAQ standards, AAA-MS quantification results were consistent with classical AAA measurements. Compared to AAA assay, AAA-MS was much faster and was 100-fold more sensitive for peptide and protein quantification. Finally, thanks to the development of a labeled protein standard, we also extended AAA-MS analysis to the quantification of unlabeled proteins.

  11. Measurements and Modeling of Nitric Oxide Formation in Counterflow, Premixed CH4/O2/N2 Flames

    NASA Technical Reports Server (NTRS)

    Thomsen, D. Douglas; Laurendeau, Normand M.

    2000-01-01

    Laser-induced fluorescence (LIF) measurements of NO concentration in a variety of CH4/O2/N2 flames are used to evaluate the chemical kinetics of NO formation. The analysis begins with previous measurements in flat, laminar, premixed CH4/O2/N2 flames stabilized on a water-cooled McKenna burner at pressures ranging from 1 to 14.6 atm, equivalence ratios from 0.5 to 1.6, and volumetric nitrogen/oxygen dilution ratios of 2.2, 3.1 and 3.76. These measured results are compared to predictions to determine the capabilities and limitations of the comprehensive kinetic mechanism developed by the Gas Research Institute (GRI), version 2.11. The model is shown to predict well the qualitative trends of NO formation in lean-premixed flames, while quantitatively underpredicting NO concentration by 30-50%. For rich flames, the model is unable to even qualitatively match the experimental results. These flames were found to be limited by low temperatures and an inability to separate the flame from the burner surface. In response to these limitations, a counterflow burner was designed for use in opposed premixed flame studies. A new LIF calibration technique was developed and applied to obtain quantitative measurements of NO concentration in laminar, counterflow premixed, CH4/O2/N2 flames at pressures ranging from 1 to 5.1 atm, equivalence ratios of 0.6 to 1.5, and an N2/O2 dilution ratio of 3.76. The counterflow premixed flame measurements are combined with measurements in burner-stabilized premixed flames and counterflow diffusion flames to build a comprehensive database for analysis of the GRI kinetic mechanism. Pathways, quantitative reaction path and sensitivity analyses are applied to the GRI mechanism for these flame conditions. The prompt NO mechanism is found to severely underpredict the amount of NO formed in rich premixed and nitrogen-diluted diffusion flames. This underprediction is traced to uncertainties in the CH kinetics as well as in the nitrogen oxidation chemistry. Suggestions are made which significantly improve the predictive capability of the GRI mechanism in near-stoichiometric, rich, premixed flames and in atmospheric-pressure, diffusion flames. However, the modified reaction mechanism is unable to model the formation of NO in ultra-rich, premixed or in high-pressure, nonpremixed flames, thus indicating the need for additional study under these conditions.

  12. Power Plant Bromide Discharges and Downstream Drinking Water Systems in Pennsylvania.

    PubMed

    Good, Kelly D; VanBriesen, Jeanne M

    2017-10-17

    Coal-fired power plants equipped with wet flue gas desulfurization (FGD) systems have been implicated in increasing bromide levels and subsequent increases in disinfection byproducts at downstream drinking water plants. Bromide was not included as a regulated constituent in the recent steam electric effluent limitations guidelines and standards (ELGs) since the U.S. EPA analysis suggested few drinking water facilities would be affected by bromide discharges from power plants. The present analysis uses a watershed approach to identify Pennsylvania drinking water intakes downstream of wet FGD discharges and to assess the potential for bromide discharge effects. Twenty-two (22) public drinking water systems serving 2.5 million people were identified as being downstream of at least one wet FGD discharge. During mean August conditions (generally low-flow, minimal dilution) in receiving rivers, the median predicted bromide concentrations contributed by wet FGD at Pennsylvania intake locations ranged from 5.2 to 62 μg/L for the Base scenario (including only natural bromide in coal) and from 16 to 190 μg/L for the Bromide Addition scenario (natural plus added bromide for mercury control); ranges depend on bromide loads and receiving stream dilution capacity.

  13. Headspace solid-phase microextraction and gas chromatographic analysis of low-molecular-weight sulfur volatiles with pulsed flame photometric detection and quantification by a stable isotope dilution assay.

    PubMed

    Ullrich, Sebastian; Neef, Sylvia K; Schmarr, Hans-Georg

    2018-02-01

    Low-molecular-weight volatile sulfur compounds such as thiols, sulfides, disulfides as well as thioacetates cause a sulfidic off-flavor in wines even at low concentration levels. The proposed analytical method for quantification of these compounds in wine is based on headspace solid-phase microextraction, followed by gas chromatographic analysis with sulfur-specific detection using a pulsed flame photometric detector. Robust quantification was achieved via a stable isotope dilution assay using commercial and synthesized deuterated isotopic standards. The necessary chromatographic separation of analytes and isotopic standards benefits from the inverse isotope effect realized on an apolar polydimethylsiloxane stationary phase of increased film thickness. Interferences with sulfur-specific detection in wine caused by sulfur dioxide were minimized by addition of propanal. The method provides adequate validation data, with good repeatability and limits of detection and quantification. It suits the requirements of wine quality management, allowing the control of oenological treatments to counteract an eventual formation of excessively high concentration of such malodorous compounds. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The Effect of Albumin and Platelet-Poor Plasma Supplemented Botulinum A Toxin on Bioavaliability: An Experimental Rabbit Model.

    PubMed

    Sibar, Serhat; Findikcioglu, Kemal; Zinnuroglu, Murat; Cenetoglu, Seyhan

    2017-04-01

    Today, botulinum toxin is commonly used for cosmetic purposes throughout the world. Despite various agents reducing the efficiency of toxin are well defined, the studies related to increasing the bioavailability are limited. The purpose of our study is to assess the effect of the preparation of toxin by diluting with platelet-poor plasma (PPP) and/or albumin instead of standard dilution (saline) on bioavailability in cosmetic-purpose botulinum toxin applications.In the study, 24 New Zealand rabbits were used. Right anterior auricular muscle was preferred for toxin injections. Subjects were divided in 4 groups and in every group; botulinum A toxin (BTxA) that was prepared by different dilution methods was injected. 2.5 U saline-diluted BTxA was injected to the subjects in group 1, 2.5 U ready-to-use rabbit albumin-diluted BTxA was injected to group 2 and 2.5 U autologous PPP-diluted BTxA was injected to group 3 and pure saline was injected to group 4.Before the injection (0th week) and in the second, sixth, and 12th weeks after the injection, visual and electroneuromyographic evaluations of the ears of the subjects were performed.In the second week, median amplitude levels in group 2 were significantly found lower than other groups.In the sixth week, median amplitude levels in group 1 were significantly found lower than other groups.In 12th week, no significant difference was found among all the groups in terms of median amplitude levels.Visual findings were also correlated with electroneuromyographic findings.It was observed that the dilution of BTxA with albumin had caused a stronger paralysis when compared to dilution with saline or PPP at the beginning (second week); however, in the following weeks (sixth week), it was seen that dilution with saline had maintained paralysis better when compared with other dilution methods.In cosmetic BTxA applications, dilution of the toxin with albumin or PPP instead of standard dilution has no positive effect on bioavailability and such modifications regarding this kind of dilution are found unsuitable. Further studies are needed to directly relate the results with clinical applications.

  15. Effect of dilution in asymmetric recurrent neural networks.

    PubMed

    Folli, Viola; Gosti, Giorgio; Leonetti, Marco; Ruocco, Giancarlo

    2018-04-16

    We study with numerical simulation the possible limit behaviors of synchronous discrete-time deterministic recurrent neural networks composed of N binary neurons as a function of a network's level of dilution and asymmetry. The network dilution measures the fraction of neuron couples that are connected, and the network asymmetry measures to what extent the underlying connectivity matrix is asymmetric. For each given neural network, we study the dynamical evolution of all the different initial conditions, thus characterizing the full dynamical landscape without imposing any learning rule. Because of the deterministic dynamics, each trajectory converges to an attractor, that can be either a fixed point or a limit cycle. These attractors form the set of all the possible limit behaviors of the neural network. For each network we then determine the convergence times, the limit cycles' length, the number of attractors, and the sizes of the attractors' basin. We show that there are two network structures that maximize the number of possible limit behaviors. The first optimal network structure is fully-connected and symmetric. On the contrary, the second optimal network structure is highly sparse and asymmetric. The latter optimal is similar to what observed in different biological neuronal circuits. These observations lead us to hypothesize that independently from any given learning model, an efficient and effective biologic network that stores a number of limit behaviors close to its maximum capacity tends to develop a connectivity structure similar to one of the optimal networks we found. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Directed transport by surface chemical potential gradients for enhancing analyte collection in nanoscale sensors.

    PubMed

    Sitt, Amit; Hess, Henry

    2015-05-13

    Nanoscale detectors hold great promise for single molecule detection and the analysis of small volumes of dilute samples. However, the probability of an analyte reaching the nanosensor in a dilute solution is extremely low due to the sensor's small size. Here, we examine the use of a chemical potential gradient along a surface to accelerate analyte capture by nanoscale sensors. Utilizing a simple model for transport induced by surface binding energy gradients, we study the effect of the gradient on the efficiency of collecting nanoparticles and single and double stranded DNA. The results indicate that chemical potential gradients along a surface can lead to an acceleration of analyte capture by several orders of magnitude compared to direct collection from the solution. The improvement in collection is limited to a relatively narrow window of gradient slopes, and its extent strongly depends on the size of the gradient patch. Our model allows the optimization of gradient layouts and sheds light on the fundamental characteristics of chemical potential gradient induced transport.

  17. Determination of toxic elements in yerba mate by ICP-MS after diluted acid digestion under O2 pressure.

    PubMed

    Pardinho, Renan B; Dalla Vecchia, Paula; Mendes, Ana L G; Bizzi, Cezar A; Mello, Paola A; Duarte, Fabio A; Flores, Erico M M

    2018-10-15

    In this work, a procedure allowing effective digestion of a high mass of yerba mate (up to 1500 mg) using diluted HNO 3, in a system pressurized with oxygen, is proposed. Digests were suitable for direct analysis by ICP-MS, virtually free of interferences. Digestion was performed using 7 mol l -1 HNO 3 and 8 bar O 2 . The digestion efficiency was better than 92% and digests presented a relatively low acidity (<10 mmol HNO 3 ). The limit of quantification was 4.0, 1.0 and 1.0 ng g -1 for As, Cd and Pb, respectively. Under optimized conditions up to 1500 mg of sample were digested and no interferences were observed during analyses by ICP-MS, making this approach suitable for routine determination of As, Cd and Pb in yerba mate and also in agreement with the quality control requirements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Analysis of nitrosamines in water by automated SPE and isotope dilution GC/HRMS Occurrence in the different steps of a drinking water treatment plant, and in chlorinated samples from a reservoir and a sewage treatment plant effluent.

    PubMed

    Planas, Carles; Palacios, Oscar; Ventura, Francesc; Rivera, Josep; Caixach, Josep

    2008-08-15

    A method based on automated solid-phase extraction (SPE) and isotope dilution gas chromatography/high resolution mass spectrometry (GC/HRMS) has been developed for the analysis of nine nitrosamines in water samples. The combination of automated SPE and GC/HRMS for the analysis of nitrosamines has not been reported previously. The method shows as advantages the selectivity and sensitivity of GC/HRMS analysis and the high efficiency of automated SPE with coconut charcoal EPA 521 cartridges. Low method detection limits (MDLs) were achieved, along with a greater facility of the procedure and less dependence on the operator with regard to the methods based on manual SPE. Quality requirements for isotope dilution-based methods were accomplished for most analysed nitrosamines, regarding to trueness (80-120%), method precision (<15%) and MDLs (0.08-1.7 ng/L). Nineteen water samples (16 samples from a drinking water treatment plant {DWTP}, 2 chlorinated samples from a sewage treatment plant {STP} effluent, and 1 chlorinated sample from a reservoir) were analysed. Concentrations of nitrosamines in the STP effluent were 309.4 and 730.2 ng/L, being higher when higher doses of chlorine were applied. N-Nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) were the main compounds identified in the STP effluent, and NDEA was detected above 200 ng/L, regulatory level for NDMA in effluents stated in Ontario (Canada). Lower concentrations of nitrosamines were found in the reservoir (20.3 ng/L) and in the DWTP samples (n.d. -28.6 ng/L). NDMA and NDEA were respectively found in the reservoir and in treated and highly chlorinated DWTP samples at concentrations above 10 ng/L (guide value established in different countries). The highest concentrations of nitrosamines were found after chlorination and ozonation processes (ozonated, treated and highly chlorinated water) in DWTP samples.

  19. The Effects of Statistical Multiplicity of Infection on Virus Quantification and Infectivity Assays.

    PubMed

    Mistry, Bhaven A; D'Orsogna, Maria R; Chou, Tom

    2018-06-19

    Many biological assays are employed in virology to quantify parameters of interest. Two such classes of assays, virus quantification assays (VQAs) and infectivity assays (IAs), aim to estimate the number of viruses present in a solution and the ability of a viral strain to successfully infect a host cell, respectively. VQAs operate at extremely dilute concentrations, and results can be subject to stochastic variability in virus-cell interactions. At the other extreme, high viral-particle concentrations are used in IAs, resulting in large numbers of viruses infecting each cell, enough for measurable change in total transcription activity. Furthermore, host cells can be infected at any concentration regime by multiple particles, resulting in a statistical multiplicity of infection and yielding potentially significant variability in the assay signal and parameter estimates. We develop probabilistic models for statistical multiplicity of infection at low and high viral-particle-concentration limits and apply them to the plaque (VQA), endpoint dilution (VQA), and luciferase reporter (IA) assays. A web-based tool implementing our models and analysis is also developed and presented. We test our proposed new methods for inferring experimental parameters from data using numerical simulations and show improvement on existing procedures in all limits. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Communication: Potentials of mean force study of ionic liquid ion pair aggregation in polar covalent molecule solvents

    NASA Astrophysics Data System (ADS)

    Bandlamudi, Santosh Rathan Paul; Benjamin, Kenneth M.

    2018-05-01

    Molecular dynamics (MD) simulations were conducted for 1-ethyl-3-methylimidazolium methylsulfate [EMIM][MeSO4] dissolved in six polar covalent molecules [acetic acid, acetone, chloroform, dimethyl sulfoxide (DMSO), isopropyl alcohol, and methanol] to understand the free energies of ionic liquid (IL) ion pairing/aggregation in the limit of infinite dilution. Free energy landscapes or potentials of mean force (PMF) were computed using umbrella sampling and the weighted histogram analysis method. The PMF studies showed the strongest IL ion pairing in chloroform, and the strength of IL ion pairing decreases in the order of chloroform, acetone, propanol, acetic acid, DMSO, and methanol. In the limit of infinite dilution, the free energy curves for IL ion aggregation in co-solvents were characterized by two distinct minima [global (˜3.6 Å) and local (˜5.7 Å)], while free energy values at these minima differed significantly for IL in each co-solvent. The PMF studies were extended for determining the free energy of IL ion aggregation as a function of concentration of methanol. Studies showed that as the concentration of methanol increased, the free energy of ion aggregation decreased, suggesting greater ion pair stability, in agreement with previously reported MD clustering and radial distribution function data.

  1. Isotope-dilution gas chromatography-mass spectrometry method for the analysis of hydroxyurea.

    PubMed

    Garg, Uttam; Scott, David; Frazee, Clint; Kearns, Gregory; Neville, Kathleen

    2015-06-01

    Hydroxyurea is used in the treatment of various malignancies and sickle cell disease. There are limited studies on the pharmacokinetics of hydroxyurea, particularly in pediatric patients. An accurate, precise, and sensitive method is needed to support such studies and to monitor therapeutic adherence. We describe a novel gas chromatography-mass spectrometry (GC-MS) method for the determination of hydroxyurea concentration in plasma using stable labeled hydroxyurea C N2 as an internal standard. The method involved an organic extraction followed by the preparation of trimethylsilyl (TMS) derivatives of hydroxyurea for GC-MS selected ion-monitoring analysis. The following mass-to-charge (m/z) ratio ions for silated hydroxyurea and hydroxyurea C N2 were monitored: hydroxyurea-quantitative ion 277, qualifier ions 292 and 249; hydroxyurea C N2-quantitative ion 280, qualifier ion 295. This method was evaluated for reportable range, accuracy, within-run and between-run imprecisions, and limits of quantification. The reportable range for the method was 0.1-100 mcg/mL. All results were accurate within an allowable error of 15%. Within-run and between-run imprecisions were <15%. Samples were stable for at least 4 hours at room temperature, 2 months at -20°C, and 6 months at -70°C, and after 3 freeze/thaw cycles. Extraction efficiency for 1-, 5-, 10-, and 50-mcg/mL samples averaged 2.2%, 1.8%, 1.6%, and 1.4%, respectively. The isotope-dilution GC-MS method for analysis of hydroxyurea described here is accurate, sensitive, precise, and robust. Its characteristics make the method suitable for supporting pharmacokinetic studies and/or clinical therapeutic monitoring.

  2. Morphological instability of a thermophoretically growing deposit

    NASA Technical Reports Server (NTRS)

    Castillo, Jose L.; Garcia-Ybarra, Pedro L.; Rosner, Daniel E.

    1992-01-01

    The stability of the planar interface of a structureless solid growing from a depositing component dilute in a carrier fluid is studied when the main solute transport mechanism is thermal (Soret) diffusion. A linear stability analysis, carried out in the limit of low growth Peclet number, leads to a dispersion relation which shows that the planar front is unstable either when the thermal diffusion factor of the condensing component is positive and the latent heat release is small or when the thermal diffusion factor is negative and the solid grows over a thermally-insulating substrate. Furthermore, the influence of interfacial energy effects and constitutional supersaturation in the vicinity of the moving interface is analyzed in the limit of very small Schmidt numbers (small solute Fickian diffusion). The analysis is relevant to physical vapor deposition of very massive species on cold surfaces, as in recent experiments of organic solid film growth under microgravity conditions.

  3. Thromboresistant surface coatings for the measurement of cardiac output through continuous low flow peripheral A-V shunts.

    PubMed Central

    Deeb, G M; Borovetz, H S; Griffith, B P; Hardesty, R L

    1980-01-01

    The dilution technique for determining cardiac output using indocyanine green dye is limited in patients weighing less than 20 kg because of the obligatory volume loss. Reproducible achieved using the green dye dilution method by the establishment of a low flow peripheral arteriovenous shunt. The shunt materials were treated with thromboresistant agents--TDMAC (7%) and albumin (1 g/dl)--to facilitate the use of this technique without heparin. For A-V shunt flow rates of 8-30 cc/min reproducible values of cardiac output were obtained for up to 38 hours which were in good agreement with determinations made using the conventional technique of dye dilution. PMID:6986120

  4. Helium dilution refrigeration system

    DOEpatents

    Roach, Patrick R.; Gray, Kenneth E.

    1988-01-01

    A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains .sup.3 He and .sup.4 He liquids which are precooled by a coupled container containing .sup.3 He liquid, enabling the phase separation of a .sup.3 He rich liquid phase from a dilute .sup.3 He-.sup.4 He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the .sup.3 He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute .sup.3 He-.sup.4 He liquid phase.

  5. Helium dilution refrigeration system

    DOEpatents

    Roach, P.R.; Gray, K.E.

    1988-09-13

    A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation is disclosed. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains [sup 3]He and [sup 4]He liquids which are precooled by a coupled container containing [sup 3]He liquid, enabling the phase separation of a [sup 3]He rich liquid phase from a dilute [sup 3]He-[sup 4]He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the [sup 3]He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute [sup 3]He-[sup 4]He liquid phase. 2 figs.

  6. Procedures for determination of detection limits: application to high-performance liquid chromatography analysis of fat-soluble vitamins in human serum.

    PubMed

    Browne, Richard W; Whitcomb, Brian W

    2010-07-01

    Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.

  7. The immediate impact of semen diluent and rate of dilution on the sperm quality index, ATP utilization, gas exchange, and ionic balance of broiler breeder sperm.

    PubMed

    Parker, H M; McDaniel, C D

    2006-01-01

    The sperm quality index (SQI) is a tool used to predict overall rooster semen quality, fertility, and hatchability. However, semen must be diluted before SQI analysis, and research has shown that the SQI is most predictive of fertility at lower semen dilutions. Therefore, the present study was undertaken to determine why the SQI is not as predictive of fertility at higher semen dilutions and whether semen diluent type alters the SQI, adenosine triphosphate (ATP) utilization, gas exchange, and ionic balance of broiler breeder sperm. Semen was diluted with saline, seminal plasma, or minimum essential medium (MEM) from 2- to 200-fold. The following parameters were measured for each diluent type at each dilution: SQI, ATP, Na+, Ca2+, K+, Cl-, CO2, and O2. To examine the rate of sperm motility, the SQI was expressed as SQI/million sperm per mL (SQI/sperm). There was an interaction between diluent type and dilution for the SQI, SQI/sperm, CO2 generated, O2 used, as well as Na+, Ca2+, and K+ internalization. For sperm diluted with saline, the SQI declined more rapidly with increasing dilution. However, SQI/sperm increased rapidly when semen was diluted with MEM or SP. Sperm diluted in SP used ATP with increasing dilution whereas sperm diluted with saline and MEM generated ATP. Neat semen contained no free O2; however, each diluent type contained abundant O2 resulting in more O2 available as semen was diluted. Sperm diluted in SP produced more CO2 and used more O2 than semen diluted in saline or MEM. For SQI/sperm, ATP and CO2 generated, as well as Na+ and Ca2+ internalization, differences between diluent types occurred when semen was diluted 50-fold and greater. In conclusion, it appears that sperm motility, ATP utilization, gas exchange, and ionic balance are altered by diluent type and rate of dilution. These alterations in semen quality are exacerbated at semen dilutions of 50-fold and greater yielding an SQI that is not indicative of sperm motility or fertility.

  8. Total body water and lean body mass estimated by ethanol dilution

    NASA Technical Reports Server (NTRS)

    Loeppky, J. A.; Myhre, L. G.; Venters, M. D.; Luft, U. C.

    1977-01-01

    A method for estimating total body water (TBW) using breath analyses of blood ethanol content is described. Regression analysis of ethanol concentration curves permits determination of a theoretical concentration that would have existed if complete equilibration had taken place immediately upon ingestion of the ethanol; the water fraction of normal blood may then be used to calculate TBW. The ethanol dilution method is applied to 35 subjects, and comparison with a tritium dilution method of determining TBW indicates that the correlation between the two procedures is highly significant. Lean body mass and fat fraction were determined by hydrostatic weighing, and these data also prove compatible with results obtained from the ethanol dilution method. In contrast to the radioactive tritium dilution method, the ethanol dilution method can be repeated daily with its applicability ranging from diseased individuals to individuals subjected to thermal stress, strenuous exercise, water immersion, or the weightless conditions of space flights.

  9. Videodensitometric Methods for Cardiac Output Measurements

    NASA Astrophysics Data System (ADS)

    Mischi, Massimo; Kalker, Ton; Korsten, Erik

    2003-12-01

    Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.

  10. Optimization and validation of enzyme-linked immunosorbent assay for the determination of endosulfan residues in food samples.

    PubMed

    Zhang, Yan; Liu, Jun W; Zheng, Wen J; Wang, Lei; Zhang, Hong Y; Fang, Guo Z; Wang, Shuo

    2008-02-01

    In this study, an enzyme-linked immunosorbent assay (ELISA) was optimized and applied to the determination of endosulfan residues in 20 different kinds of food commodities including vegetables, dry fruits, tea and meat. The limit of detection (IC(15)) was 0.8 microg kg(-1) and the sensitivity (IC(50)) was 5.3 microg kg(-1). Three simple extraction methods were developed, including shaking on the rotary shaker at 250 r min(-1) overnight, shaking on the rotary shaker for 1 h and thoroughly mixing for 2 min. Methanol was used as the extraction solvent in this study. The extracts were diluted in 0.5% fish skin gelatin (FG) in phosphate-buffered saline (PBS) at various dilutions in order to remove the matrix interference. For cabbage (purple and green), asparagus, Japanese green, Chinese cabbage, scallion, garland chrysanthemum, spinach and garlic, the extracts were diluted 10-fold; for carrots and tea, the extracts were diluted 15-fold and 900-fold, respectively. The extracts of celery, adzuki beans and chestnuts, were diluted 20-fold to avoid the matrix interference; ginger, vegetable soybean and peanut extracts were diluted 100-fold; mutton and chicken extracts were diluted 10-fold and for eel, the dilution was 40-fold. Average recoveries were 63.13-125.61%. Validation was conducted by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). The results of this study will be useful to the wide application of an ELISA for the rapid determination of pesticides in food samples.

  11. Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia.

    PubMed

    Rossi, P; Oldner, A; Wanecek, M; Leksell, L G; Rudehill, A; Konrad, D; Weitzberg, E

    2003-03-01

    To compare a molecular double-indicator dilution technique with the gravimetrical reference method for measurement of extra-vascular lung water in porcine endotoxin shock. Open comparative experimental study. Animal research laboratory. In fourteen anaesthetised, mechanically ventilated landrace pigs, central and pulmonary haemodynamics as well as pulmonary gas exchange were measured. Extra-vascular lung water was quantitated gravimetrically as well as with a molecular double indicator dilution technique. Eight of these animals were subjected to endotoxaemia, the rest serving as sham controls. No difference in extra-vascular lung water was observed between the two methods in sham animals. Furthermore, extra-vascular lung water assessed with the molecular double-indicator dilution technique at the initiation of endotoxin infusion did not differ significantly from the corresponding values for sham animals. Endotoxaemia induced a hypodynamic shock with concurrent pulmonary hypertension and a pronounced deterioration in gas exchange. No increase in extra-vascular lung water was detected with the molecular double-indicator dilution technique in response to endotoxin, whereas this parameter was significantly higher when assessed with the gravimetric method. The molecular double-indicator dilution technique showed similar results as the gravimetrical method for assessment of extra-vascular lung water in non-endotoxaemic conditions. However, during endotoxin-induced lung injury the molecular double indicator dilution technique failed to detect the significant increase in extra-vascular lung water as measured by the gravimetric method. These data suggest that the molecular double indicator dilution technique may be of limited value during sepsis-induced lung injury.

  12. A theoretical framework for modeling dilution enhancement of non-reactive solutes in heterogeneous porous media.

    PubMed

    de Barros, F P J; Fiori, A; Boso, F; Bellin, A

    2015-01-01

    Spatial heterogeneity of the hydraulic properties of geological porous formations leads to erratically shaped solute clouds, thus increasing the edge area of the solute body and augmenting the dilution rate. In this study, we provide a theoretical framework to quantify dilution of a non-reactive solute within a steady state flow as affected by the spatial variability of the hydraulic conductivity. Embracing the Lagrangian concentration framework, we obtain explicit semi-analytical expressions for the dilution index as a function of the structural parameters of the random hydraulic conductivity field, under the assumptions of uniform-in-the-average flow, small injection source and weak-to-mild heterogeneity. Results show how the dilution enhancement of the solute cloud is strongly dependent on both the statistical anisotropy ratio and the heterogeneity level of the porous medium. The explicit semi-analytical solution also captures the temporal evolution of the dilution rate; for the early- and late-time limits, the proposed solution recovers previous results from the literature, while at intermediate times it reflects the increasing interplay between large-scale advection and local-scale dispersion. The performance of the theoretical framework is verified with high resolution numerical results and successfully tested against the Cape Cod field data. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  14. Breastmilk donations: Bacteriological assessment, analysis of causes of non-compliance and suggestions for improvement.

    PubMed

    Mullié, C; Obin, O; Outurquin, G; Grognet, S; Léké, A; Adjidé, C

    2018-05-01

    A total of 1099 breastmilk donations received by the milk bank at the Amiens University Hospital from January to June 2016 were assessed for bacteriological contamination according to French regulations. This consisted in enumerating the total aerobic flora before and after heat treatment as well as the specific enumeration of coagulase-positive staphylococci. Results above the mandatory limits for at least one of these parameters were found in 25.9% of the donations, resulting in the destruction of approximately one-quarter of the volume of the donations (∼195L). This is a huge loss in both economic and health-related terms for neonates, especially for pre-terms. To identify ways to improve the bacteriological assessment results and reduce the percentage of discarded milk, an analysis of the causes was conducted. The two main causes of non-compliance were the detection of a cultivable aerobic flora after heat treatment and the presence of coagulase-positive staphylococci above the mandatory limit (11.7% and 11.2% of the tested donations, respectively). Bacillus spp. were the leading cause of post-heat-treatment non-compliance. Therefore, the implementation of better environmental control could help reduce this kind of contamination. As for samples harboring coagulase-positive staphylococci, a further detection of toxins using molecular biology techniques could help discriminate actual health-hazardous donations that have to be destroyed while enabling the use of toxin-negative donations. Nevertheless, the economic viability of this proposal needs to be further assessed because these techniques are costly. Finally, a change in breastmilk dilutions used to enumerate the total aerobic flora to better reflect the actual level of these bacteria in the milk was proposed. Indeed, the comparison of various combinations of milk dilutions led to the conclusion that the association of the 1/10 and 1/100 dilutions was the best compromise between technical ease of enumeration and ensuring the safety of the donations. Implementing these suggestions would help reduce the rate of non-compliance and give better access to safe breastmilk donations for neonates. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  15. Design and verification of a highly reliable Linear-After-The-Exponential PCR (LATE-PCR) assay for the detection of African swine fever virus.

    PubMed

    Ronish, B; Hakhverdyan, M; Ståhl, K; Gallardo, C; Fernandez-Pinero, J; Belák, S; Leblanc, N; Wangh, L

    2011-03-01

    African swine fever virus (ASFV) is a highly pathogenic DNA virus that is the causative agent of African swine fever (ASF), an infectious disease of domestic and wild pigs of all breeds and ages, causing a range of syndromes. Acute disease is characterized by high fever, haemorrhages in the reticuloendothelial system, and a high mortality rate. A powerful novel diagnostic assay based on the Linear-After-The-Exponential-PCR (LATE-PCR) principle was developed to detect ASFV. LATE-PCR is an advanced form of asymmetric PCR which results in direct amplification of large amount of single-stranded DNA. Fluorescent readings are acquired using endpoint analysis after PCR amplification. Amplification of the correct product is verified by melting curve analysis. The assay was designed to amplify the VP72 gene of ASFV genome. Nineteen ASFV DNA cell culture virus strains and three tissue samples (spleen, tonsil, and liver) from infected experimental pigs were tested. Virus was detected in all of the cell culture and tissue samples. None of five ASFV-related viruses tested produced a positive signal, demonstrating the high specificity of the assay. The sensitivity of the LATE-PCR assay was determined in two separate real-time monoplex reactions using samples of synthetic ASFV and synthetic control-DNA targets that were diluted serially from 10⁹ to 1 initial copies per reaction. The detection limit was 1 and 10 copies/reaction, respectively. The sensitivity of the assay was also tested in a duplex end-point reactions comprised of a constant level of 150 copies of synthetic control-DNA and a clinical sample of spleen tissue diluted serially from 10⁻¹ to 10⁻⁵. The detection limit was 10⁻⁵ dilution which corresponds to approximately 1 copy/reaction. Since the assay is designed to be used in either laboratory settings or in a portable PCR machine (Bio-Seeq Portable Veterinary Diagnostics Laboratory; Smiths Detection, Watford UK), the LATE-PCR provides a robust and novel tool for the diagnosis of ASF both in the laboratory and in the field. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Production and characterization of murine monoclonal antibody against synthetic peptide of CD34.

    PubMed

    Maleki, Leili Aghebati; Majidi, Jafar; Baradaran, Behzad; Abdolalizadeh, Jalal; Akbari, Aliakbar Movassaghpour

    2013-01-01

    The treatment of hematologic malignancies and immunodeficiency diseases are offered by hematopoietic stem cells (HSCs) as a unique self-renewal and differentiation source which most commonly is selected by CD34 surface marker for HSC. The purpose of this study was to develop and characterize monoclonal antibody against CD34 antigen for detection of hematopoietic stem cells. Balb/c mice were immunized with two synthetic peptides of CD34 and Spleen cells were fused with SP2/0.Fused cells were grown in hypoxanthine, aminopterine and thymidine (HAT) selective medium and cloned by limiting dilution. Large scale of monoclonal antibodies was produced by mouse ascites production of mAb (in vivo) method. Monoclonal antibody was purified by chromatography. Then reactivity of these antibodies was evaluated in different immunological assays including ELISA, immunofluorescence (IF), western blot (WB) and flowcytometry. In this study, between five positive clone wells, two clones were chosen for limiting dilution. Limiting dilution product was one monoclone (3-D5 monoclone) with absorbance about 2. Isotype of this mAb was identified as IgG1 class with Kappa (κ) light chain. This antibody is highly specific and functional in biomedical applications such as ELISA, flowcytometry, immunofluorescence, and western blot assays.

  17. Nanosized solvent superstructures in ultramolecular aqueous dilutions: twenty years' research using water proton NMR relaxation.

    PubMed

    Demangeat, Jean-Louis

    2013-04-01

    proton nuclear magnetic resonance (NMR) relaxation times T1, T2, T1/T2 are sensitive to motion and organization of water molecules. Especially, increase in T1/T2 reflects a higher degree of structuring. My purpose was to look at physical changes in water in ultrahigh aqueous dilutions. Samples were prepared by iterative centesimal (c) dilution with vigorous agitation, ranging between 3c and 24c (Avogadro limit 12c). Solutes were silica-lactose, histamine, manganese-lactose. Solvents were water, NaCl 0.15 M or LiCl 0.15 M. Solvents underwent strictly similar, simultaneous dilution/agitation, for each level of dilution, as controls. NMR relaxation was studied within 0.02-20 MHz. No changes were observed in controls. Increasing T1 and T1/T2 were found in dilutions, which persisted beyond 9c (manganese-lactose), 10c (histamine) and 12c (silica-lactose). For silica-lactose in LiCl, continuous decrease in T2 with increase in T1/T2 within the 12c-24c range indicated growing structuring of water despite absence of the initial solute. All changes vanished after heating/cooling. These findings were interpreted in terms of nanosized (>4-nm) supramolecular structures involving water, nanobubbles and ions, if any. Additional study of low dilutions of silica-lactose revealed increased T2 and decreased T1/T2 compared to solvent, within the 10(-3)-10(-6) range, reflecting transient solvent destructuring. This could explain findings at high dilution. Proton NMR relaxation demonstrated modifications of the solvent throughout the low to ultramolecular range of dilution. The findings suggested the existence of superstructures that originate stereospecifically around the solute after an initial destructuring of the solvent, developing more upon dilution and persisting beyond 12c. Copyright © 2013 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  18. Toxicity of contaminated sediments in dilution series with control sediments

    USGS Publications Warehouse

    Nelson, M.K.; Landrum, P.F.; Burton, G.A.; Klaine, S.J.; Crecelius, E.A.; Byl, T.D.; Gossiaux, Duane C.; Tsymbal, V.N.; Cleveland, L.; Ingersoll, Christopher G.; Sasson-Brickson, G.

    1993-01-01

    The use of dilutions has been the foundation of our approach for assessing contaminated water, and accordingly, it may be important to establish similar or parallel approaches for sediment dilutions. Test organism responses to dilution gradients can identify the degree of necessary sediment alteration to reduce the toxicity. Using whole sediment dilutions to represent the complex interactions of in situ sediments can identify the toxicity, but the selection of the appropriate diluent for the contaminated sediment may affect the results and conclusions drawn. Contaminated whole sediments were examined to evaluate the toxicity of dilutions of sediments with a diversity of test organisms. Dilutions of the contaminated sediments were prepared with differing diluents that varied in organic carbon content, particle size distribution, and volatile solids. Studies were conducted using four macroinvertebrates and a vascular, rooted plant. Responses by some test organisms followed a sigmoidal dose-response curve, but others followed a U-shaped curve. Initial dilutions reduced toxicity as expected, but further dilution resulted in an increase in toxicity. The type of diluent used was an important factor in assessing the sediment toxicity, because the control soil reduced toxicity more effectively than sand as a diluent of the same sediment. Using sediment chemical and physical characteristics as an indicator of sediment dilution may not be as useful as chemical analysis of contaminants, but warrants further investigation.

  19. Upfront dilution of ferritin samples to reduce hook effect, improve turnaround time and reduce costs.

    PubMed

    Wu, Shu Juan; Hayden, Joshua A

    2018-02-15

    Sandwich immunoassays offer advantages in the clinical laboratory but can yield erroneously low results due to hook (prozone) effect, especially with analytes whose concentrations span several orders of magnitude such as ferritin. This study investigated a new approach to reduce the likelihood of hook effect in ferritin immunoassays by performing upfront, five-fold dilutions of all samples for ferritin analysis. The impact of this change on turnaround time and costs were also investigated. Ferritin concentrations were analysed in routine clinical practice with and without upfront dilutions on Siemens Centaur® XP (Siemens Healthineers, Erlang, Germany) immunoanalysers. In addition, one month of baseline data (1026 results) were collected prior to implementing upfront dilutions and one month of data (1033 results) were collected after implementation. Without upfront dilutions, hook effect was observed in samples with ferritin concentrations as low as 86,028 µg/L. With upfront dilutions, samples with ferritin concentrations as high as 126,050 µg/L yielded values greater than the measurement interval and would have been diluted until an accurate value was obtained. The implementation of upfront dilution of ferritin samples led to a decrease in turnaround time from a median of 2 hours and 3 minutes to 1 hour and 18 minutes (P = 0.002). Implementation of upfront dilutions of all ferritin samples reduced the possibility of hook effect, improved turnaround time and saved the cost of performing additional dilutions.

  20. Quantification of ferritin bound iron in human serum using species-specific isotope dilution mass spectrometry.

    PubMed

    Ren, Yao; Walczyk, Thomas

    2014-09-01

    Ferritin is a hollow sphere protein composed of 24 subunits that can store up to 4500 iron atoms in its inner cavity. It is mainly found in the liver and spleen but also in serum at trace levels. Serum ferritin is considered as the best single indicator in assessing body iron stores except liver or bone marrow biopsy. However, it is confounded by other disease conditions. Ferritin bound iron (FBI) and ferritin saturation have been suggested as more robust biomarkers. The current techniques for FBI determination are limited by low antibody specificity, low instrument sensitivity and possible analyte losses during sample preparation. The need for a highly sensitive and reliable method is widely recognized. Here we describe a novel technique to detect serum FBI using species-specific isotope dilution mass spectrometry (SS-IDMS). [(57)Fe]-ferritin was produced by biosynthesis and in vitro labeling with the (57)Fe spike in the form of [(57)Fe]-citrate after cell lysis and heat treatment. [(57)Fe]-ferritin for sample spiking was further purified by fast liquid protein chromatography. Serum ferritin and added [(57)Fe]-ferritin were separated from other iron species by ultrafiltration followed by isotopic analysis of FBI using negative thermal ionization mass spectrometry. Repeatability of our assay is 8% with an absolute detection limit of 18 ng FBI in the sample. As compared to other speciation techniques, SS-IDMS offers maximum control over sample losses and species conversion during analysis. The described technique may therefore serve as a reference technique for clinical applications of FBI as a new biomarker for assessing body iron status.

  1. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    PubMed Central

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  2. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    PubMed

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  3. Compositional analysis of dilute nitride doped indium antimonide bulk crystal by VDS technique

    NASA Astrophysics Data System (ADS)

    Deshpande, Manisha; Maske, Dilip; Choudhari, Rashmi; Arora, Brij Mohan; Gadkari, Dattatray

    2016-05-01

    Dilute nitrides are suitable materials for fabrication of devices in detection of long wavelength infrared region. Dilute nitride doped Indium antimonide bulk crystals were grown using vertical directional solidification technique. The compositional characteristics of the crystals were carried out using EDS. The analysis was simulated and compared with observations using DTSA II software for accuracy. The ingots have uniform composition of Indium and Antimony. The actual nitrogen composition measured using EDS was 0.136% for doped nitrogen composition 0.1% except near conical end where it was 0.1%. The study of bonding between nitrogen, Indium and antimony was carried out using SIMS. The analysis shows strong presence of In-N bonding along with In-Sb bonds which indicates nitrogen has replaced antimony atoms in crystal lattice.

  4. LC-HR-MS/MS standard urine screening approach: Pros and cons of automated on-line extraction by turbulent flow chromatography versus dilute-and-shoot and comparison with established urine precipitation.

    PubMed

    Helfer, Andreas G; Michely, Julian A; Weber, Armin A; Meyer, Markus R; Maurer, Hans H

    2017-02-01

    Comprehensive urine screening for drugs and metabolites by LC-HR-MS/MS using Orbitrap technology has been described with precipitation as simple workup. In order to fasten, automate, and/or simplify the workup, on-line extraction by turbulent flow chromatography and a dilute-and-shoot approach were developed and compared. After chromatographic separation within 10min, the Q-Exactive mass spectrometer was run in full scan mode with positive/negative switching and subsequent data dependent acquisition mode. The workup approaches were validated concerning selectivity, recovery, matrix effects, process efficiency, and limits of identification and detection for typical drug representatives and metabolites. The total workup time for on-line extraction was 6min, for the dilution approach 3min. For comparison, the established urine precipitation and evaporation lasted 10min. The validation results were acceptable. The limits for on-line extraction were comparable with those described for precipitation, but lower than for dilution. Thanks to the high sensitivity of the LC-HR-MS/MS system, all three workup approaches were sufficient for comprehensive urine screening and allowed fast, reliable, and reproducible detection of cardiovascular drugs, drugs of abuse, and other CNS acting drugs after common doses. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Application of a luminescent bacterial biosensor for the detection of tetracyclines in routine analysis of poultry muscle samples.

    PubMed

    Pikkemaat, M G; Rapallini, M L B A; Karp, M T; Elferink, J W A

    2010-08-01

    Tetracyclines are extensively used in veterinary medicine. For the detection of tetracycline residues in animal products, a broad array of methods is available. Luminescent bacterial biosensors represent an attractive inexpensive, simple and fast method for screening large numbers of samples. A previously developed cell-biosensor method was subjected to an evaluation study using over 300 routine poultry samples and the results were compared with a microbial inhibition test. The cell-biosensor assay yielded many more suspect samples, 10.2% versus 2% with the inhibition test, which all could be confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Only one sample contained a concentration above the maximum residue limit (MRL) of 100 microg kg(-1), while residue levels in most of the suspect samples were very low (<10 microg kg(-1)). The method appeared to be specific and robust. Using an experimental set-up comprising the analysis of a series of three sample dilutions allowed an appropriate cut-off for confirmatory analysis, limiting the number of samples and requiring further analysis to a minimum.

  6. Automatic numerical evaluation of vacancy-mediated transport for arbitrary crystals: Onsager coefficients in the dilute limit using a Green function approach

    NASA Astrophysics Data System (ADS)

    Trinkle, Dallas R.

    2017-10-01

    A general solution for vacancy-mediated diffusion in the dilute-vacancy/dilute-solute limit for arbitrary crystal structures is derived from the master equation. A general numerical approach to the vacancy lattice Green function reduces to the sum of a few analytic functions and numerical integration of a smooth function over the Brillouin zone for arbitrary crystals. The Dyson equation solves for the Green function in the presence of a solute with arbitrary but finite interaction range to compute the transport coefficients accurately, efficiently and automatically, including cases with very large differences in solute-vacancy exchange rates. The methodology takes advantage of the space group symmetry of a crystal to reduce the complexity of the matrix inversion in the Dyson equation. An open-source implementation of the algorithm is available, and numerical results are presented for the convergence of the integration error of the bare vacancy Green function, and tracer correlation factors for a variety of crystals including wurtzite (hexagonal diamond) and garnet.

  7. In-gel multiple displacement amplification of long DNA fragments diluted to the single molecule level.

    PubMed

    Michikawa, Yuichi; Sugahara, Keisuke; Suga, Tomo; Ohtsuka, Yoshimi; Ishikawa, Kenichi; Ishikawa, Atsuko; Shiomi, Naoko; Shiomi, Tadahiro; Iwakawa, Mayumi; Imai, Takashi

    2008-12-15

    The isolation and multiple genotyping of long individual DNA fragments are needed to obtain haplotype information for diploid organisms. Limiting dilution of sample DNA followed by multiple displacement amplification is a useful technique but is restricted to short (<5 kb) DNA fragments. In the current study, a novel modification was applied to overcome these problems. A limited amount of cellular DNA was carefully released from intact cells into a mildly heated alkaline agarose solution and mixed thoroughly. The solution was then gently aliquoted and allowed to solidify while maintaining the integrity of the diluted DNA. Exogenously provided Phi29 DNA polymerase was used to perform consistent genomic amplification with random hexameric oligonucleotides within the agarose gels. Simple heat melting of the gel allowed recovery of the amplified materials in a solution of the polymerase chain reaction (PCR)-ready form. The haplotypes of seven SNPs spanning 240 kb of the DNA surrounding the human ATM gene region on chromosome 11 were determined for 10 individuals, demonstrating the feasibility of this new method.

  8. Capturing Cyclic Variability in EGR Dilute SI Combustion using Multi-Cycle RANS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarcelli, Riccardo; Sevik, James; Wallner, Thomas

    Dilute combustion is an effective approach to increase the thermal efficiency of spark-ignition (SI) internal combustion engines (ICEs). However, high dilution levels typically result in large cycle-to-cycle variations (CCV) and poor combustion stability, therefore limiting the efficiency improvement. In order to extend the dilution tolerance of SI engines, advanced ignition systems are the subject of extensive research. When simulating the effect of the ignition characteristics on CCV, providing a numerical result matching the measured average in-cylinder pressure trace does not deliver useful information regarding combustion stability. Typically Large Eddy Simulations (LES) are performed to simulate cyclic engine variations, since Reynold-Averagedmore » Navier-Stokes (RANS) modeling is expected to deliver an ensemble-averaged result. In this paper it is shown that, when using RANS, the cyclic perturbations coming from different initial conditions at each cycle are not damped out even after many simulated cycles. As a result, multi-cycle RANS results feature cyclic variability. This allows evaluating the effect of advanced ignition sources on combustion stability but requires validation against the entire cycle-resolved experimental dataset. A single-cylinder GDI research engine is simulated using RANS and the numerical results for 20 consecutive engine cycles are evaluated for several operating conditions, including stoichiometric as well as EGR dilute operation. The effect of the ignition characteristics on CCV is also evaluated. Results show not only that multi-cycle RANS simulations can capture cyclic variability and deliver similar trends as the experimental data, but more importantly that RANS might be an effective, lower-cost alternative to LES for the evaluation of ignition strategies for combustion systems that operate close to the stability limit.« less

  9. Comparison of Screening Dilution and Automated Reading for Antinuclear Antibody Detection on HEP2 Cells in the Monitoring of Connective Tissue Diseases.

    PubMed

    Depincé-Berger, Anne E; Moreau, Amelie; Bossy, Virginie; Genin, Christian; Rinaudo, Melanie; Paul, Stephane

    2016-09-01

    Indirect immunofluorescence plays a major role in the detection of antinuclear antibodies (ANAs) and follow-up of their titers in the context of connective tissue diseases. Given the numerous unfavorable features of the conventional manual reading of HEP2 slides (need of time and expert morphologists for the reading, lack of standardization, subjectivity of the interpretation), the biomedical industry has developed automated techniques of slide preparation and microscope reading. We collected 49 sera beforehand analyzed by the conventional reading of slides. They were prepared again by QUANTA-Lyser(®) and reanalyzed in four different conditions: two dilutions of screening (1/40 and 1/80), two different systems of analysis, NOVA View(®) automated reading (INOVA Diagnostics), then confirmation by the operator, and conventional manual reading by two different qualified operators. The analysis was realized in blind of the first interpretation and clinical diagnosis. The sera were classified in four groups, on the basis of the results of the first analysis: negative sera (titer < 1/160; 11 patients), low positives (titer at 1/160; 18 patients), moderated positives (titers between 1/320 and 1/640; 10 patients), and strong positives (titers between 1/1,280 and 1/2,560; 10 patients). Among the 49 patients, 13 presented a connective tissue disease including 4 systemic scleroderma (SS), 3 rheumatoid arthritis (RA), 2 Goujerot-Sjogren (GS), 2 systemic lupus erythematosus (SLE), 1 polymyositis (PM), 1 Raynaud's syndrome (RS), and 1 CREST syndrome. One patient presented both an SLE and an SS. Regarding the screening dilution, the 1/40 dilution is less specific than the 1/80 dilution for both the systems of analysis (5.6% vs. 16.7% for the manual reading, and 27.8% vs. 50% for the automated reading). It also generates statistically more false positives (P = 0.037 for the conventional analysis and P = 0.003 for the automated system). The automated NOVA View(®) reading of slides allows a gain in specificity for both dilutions, and also statistically less false positives (P = 0.002 at the 1/40 and P = 0.0006 at the 1/80), and detriment of the sensitivity at the highest dilution (84.6% vs. 92.3% with manual reading). Thus, according to our analysis of 49 sera, the automated NOVA View(®) system of reading of slides at the dilution 1/80 seems to be a successful condition for the detection of ANAs on HEP2 cells, close to the significance (P = 0.067). The automated NOVA View(®) reading of slides allows saving time, and an improvement in the standardization. Nevertheless, it requires a confirmation by a qualified operator, to interpret mixed patterns in particular. © 2016 Wiley Periodicals, Inc.

  10. Decay dynamics in the coupled-dipole model

    NASA Astrophysics Data System (ADS)

    Araújo, M. O.; Guerin, W.; Kaiser, R.

    2018-06-01

    Cooperative scattering in cold atoms has gained renewed interest, in particular in the context of single-photon superradiance, with the recent experimental observation of super- and subradiance in dilute atomic clouds. Numerical simulations to support experimental signatures of cooperative scattering are often limited by the number of dipoles which can be treated, well below the number of atoms in the experiments. In this paper, we provide systematic numerical studies aimed at matching the regime of dilute atomic clouds. We use a scalar coupled-dipole model in the low excitation limit and an exclusion volume to avoid density-related effects. Scaling laws for super- and subradiance are obtained and the limits of numerical studies are pointed out. We also illustrate the cooperative nature of light scattering by considering an incident laser field, where half of the beam has a ? phase shift. The enhanced subradiance obtained under such condition provides an additional signature of the role of coherence in the detected signal.

  11. In vitro effects of 3% hypertonic saline and 20% mannitol on canine whole blood coagulation and platelet function.

    PubMed

    Adamik, Katja-Nicole; Butty, Emmanuelle; Howard, Judith

    2015-09-24

    Hyperosmolar therapy, using either mannitol or hypertonic saline (HTS), is considered the treatment of choice for intracranial hypertension. However, hyperosmolar agents may impair coagulation and platelet function, limiting their use in patients at risk for hemorrhage. Despite this, studies evaluating the effects of mannitol compared to other hyperosmolar agents in dogs are largely lacking. The aim of this study was to compare the in vitro effects on global hemostasis and platelet function of 20% mannitol and 3% HTS on canine blood. Citrated whole blood from 15 healthy dogs was diluted with 0.9% saline, 20% mannitol and 3% HTS in ratios of 1:16 and 1:8. Rotational thromboelastometry (ROTEM) was used to assess clotting time (CT), clot formation time (CFT) and maximal clot firmness (MCF) following extrinsic activation (Ex-tem) and after platelet inhibition (Fib-tem). A platelet function analyzer (PFA-100) was used to assess closure time (Ct(PFA)). No significant differences were observed between untreated whole blood and samples diluted with saline. Samples diluted with both mannitol and HTS were hypocoagulable compared to untreated whole blood samples. At a dilution of 1:16, no significant differences were found between any measured parameter in samples diluted with saline compared to mannitol or HTS. At a 1:8 dilution, Ct(PFA) was prolonged in samples diluted with mannitol and HTS compared to saline, and Ct(PFA) was prolonged more with mannitol than HTS. Ex-tem CT was increased at a 1:8 dilution with mannitol compared to HTS. Ex-tem CFT was prolonged at a 1:8 dilution with both agents compared to saline, and was prolonged more with mannitol than HTS. Ex-tem MCF was reduced at a 1:8 dilution with both agents compared to saline. Data in this study indicate that both mannitol and HTS affect canine platelet function and whole blood coagulation in vitro in a dose-dependent fashion. The most pronounced effects were observed after high dilutions with mannitol, which impaired platelet aggregation, clot formation time, clot strength, and fibrin formation significantly more than HTS. Further in vivo studies are necessary before recommendations can be made.

  12. Media and dilution procedures tested to minimize handling effects on human, rabbit, and bull sperm for computer-assisted sperm analysis (CASA).

    PubMed

    Farrell, P B; Foote, R H; McArdle, M M; Trouern-Trend, V L; Tardif, A L

    1996-01-01

    Proper handling of semen prior to computer-assisted sperm analysis (CASA) is critical if the analysis is to be representative of the fresh sample. The effects of diluting medium or dilution and holding time before CASA on multiple sperm characteristics were studied. Four replicates of unselected semen samples from each of eight human donors were diluted with phosphate-buffered saline (PBS)-glucose plus bovine serum albumin (BSA), with Tyrode's albumen lactate pyruvate (TALP), and with high-potassium TALP (K-TALP) to a concentration of approximately 25 x 10(6) sperm/ml. The diluted semen was held for 0, 1, and 2 hours at approximately 30 degrees C before CASA, with little difference between the three diluents in all 12 variables measured. There was a decline of 3-6% in the proportion of motile sperm over a 2-hour period (P < 0.05). Donors were the largest source of differences (P < 0.05). Rabbit sperm (five bucks, four ejaculates per buck) were processed in a manner similar to that of the human sperm. There was a major effect of media. The average percentages of motile sperm over 2 hours in TALP, K-TALP, and PBS were 76, 42, and 29%, respectively (P < 0.05), with a decline of only 3% in TALP during the 2 hours. Hyperactivity and other characteristics were affected by treatment. Donors were a large source of variation. Bull semen (10 bulls, two ejaculates per bull) either was not diluted or diluted with TALP 2x or 4x and held for 0, 1, and 2 hours at 30 degrees C. It was then diluted to 25 x 10(6) sperm/ml with TALP. There was little change in most sperm characteristics in any treatment during the first hour, although many of the changes were statistically significant. The percentage of motile sperm in undiluted semen declined from 87% to 82% over 2 hours. Modified TALP was a suitable medium for sperm from all three species, and a simple PBS-glucose-BSA medium can be used for human sperm.

  13. Wheat and ultra high diluted gibberellic acid--further experiments and re-analysis of data.

    PubMed

    Endler, Peter Christian; Scherer-Pongratz, Waltraud; Lothaller, Harald; Stephen, Saundra

    2015-10-01

    Following studies (a) on wheat seedlings and ultra high diluted silver nitrate, and (b) on amphibians and an ultra high diluted hormone, (c) a bio-assay on wheat and extremely diluted gibberellic acid was standardized. This assay was intended to combine the easy-to-handle aspect of (a) and biologically interesting aspects of (b). The purpose of the data analysis presented here was to investigate the influence of an extreme dilution of gibberellic acid on wheat stalk length and to determine the influence of external factors on the experimental outcome. Grains of winter wheat (Triticum aestivum, Capo variety) were observed under the influence of extremely diluted gibberellic acid (10(-30)) prepared by stepwise dilution and agitation according to a protocol derived from homeopathy ('G30x'). Analogously prepared water was used for control ('W30x'). 16 experiments including 8000+8000 grains were performed by 9 researchers. Experiments that were performed between January and April showed inconsistent results, whereas most of the experiments performed between September and December showed shorter stalks in the G30x group. This was confirmed by correlation analysis (p<0.01). Thus winter/spring experiments and autumn experiments were analysed separately. When all 10 autumn experiments were pooled, mean stalk lengths (mm) were 48.3±21.4 for the verum group and 52.1±20.4 for control (mean±SD) at grain level (N=5000 per group) and ±5.3 and ±5.1 respectively at dish level. In other words, verum stalk length (92.67%) was 7.33% smaller than control stalk length (100%). The effect size is small when calculation is done on the basis of grains (d=0.18) but, due to the smaller SD at dish level, medium when done on the basis of dishes (d=0.73). The inhibiting effect was observed by 6 of the 6 researchers who performed the autumn experiments. The model may be useful for further research as there exists a theoretical justification due to previous studies with wheat and extremely diluted silver nitrate, as well as to previous studies with amphibians and diluted hormones, and its methods are well standardized. Data confirm the hypothesis that information can be stored in the test liquid, even at a dilution of the original substance beyond Avogadro's value; and that the wheat bio-assay is sensitive to such information. Copyright © 2015 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  14. Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.

    PubMed

    Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A

    2018-02-01

    This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Analysis of antibody aggregate content at extremely high concentrations using sedimentation velocity with a novel interference optics.

    PubMed

    Schilling, Kristian; Krause, Frank

    2015-01-01

    Monoclonal antibodies represent the most important group of protein-based biopharmaceuticals. During formulation, manufacturing, or storage, antibodies may suffer post-translational modifications altering their physical and chemical properties. Such induced conformational changes may lead to the formation of aggregates, which can not only reduce their efficiency but also be immunogenic. Therefore, it is essential to monitor the amount of size variants to ensure consistency and quality of pharmaceutical antibodies. In many cases, antibodies are formulated at very high concentrations > 50 g/L, mostly along with high amounts of sugar-based excipients. As a consequence, all routine aggregation analysis methods, such as size-exclusion chromatography, cannot monitor the size distribution at those original conditions, but only after dilution and usually under completely different solvent conditions. In contrast, sedimentation velocity (SV) allows to analyze samples directly in the product formulation, both with limited sample-matrix interactions and minimal dilution. One prerequisite for the analysis of highly concentrated samples is the detection of steep concentration gradients with sufficient resolution: Commercially available ultracentrifuges are not able to resolve such steep interference profiles. With the development of our Advanced Interference Detection Array (AIDA), it has become possible to register interferograms of solutions as highly concentrated as 150 g/L. The other major difficulty encountered at high protein concentrations is the pronounced non-ideal sedimentation behavior resulting from repulsive intermolecular interactions, for which a comprehensive theoretical modelling has not yet been achieved. Here, we report the first SV analysis of highly concentrated antibodies up to 147 g/L employing the unique AIDA ultracentrifuge. By developing a consistent experimental design and data fit approach, we were able to provide a reliable estimation of the minimum content of soluble aggregates in the original formulations of two antibodies. Limitations of the procedure are discussed.

  16. Blood volume analysis: a new technique and new clinical interest reinvigorate a classic study.

    PubMed

    Manzone, Timothy A; Dam, Hung Q; Soltis, Daniel; Sagar, Vidya V

    2007-06-01

    Blood volume studies using the indicator dilution technique and radioactive tracers have been performed in nuclear medicine departments for over 50 y. A nuclear medicine study is the gold standard for blood volume measurement, but the classic dual-isotope blood volume study is time-consuming and can be prone to technical errors. Moreover, a lack of normal values and a rubric for interpretation made volume status measurement of limited interest to most clinicians other than some hematologists. A new semiautomated system for blood volume analysis is now available and provides highly accurate results for blood volume analysis within only 90 min. The availability of rapid, accurate blood volume analysis has brought about a surge of clinical interest in using blood volume data for clinical management. Blood volume analysis, long a low-volume nuclear medicine study all but abandoned in some laboratories, is poised to enter the clinical mainstream. This article will first present the fundamental principles of fluid balance and the clinical means of volume status assessment. We will then review the indicator dilution technique and how it is used in nuclear medicine blood volume studies. We will present an overview of the new semiautomated blood volume analysis technique, showing how the study is done, how it works, what results are provided, and how those results are interpreted. Finally, we will look at some of the emerging areas in which data from blood volume analysis can improve patient care. The reader will gain an understanding of the principles underlying blood volume assessment, know how current nuclear medicine blood volume analysis studies are performed, and appreciate their potential clinical impact.

  17. Detection of Toxoplasma oocysts from soil by modified sucrose flotation and PCR methods.

    PubMed

    Matsuo, Junji; Kimura, Daisuke; Rai, Shiba Kumar; Uga, Shoji

    2004-06-01

    A detection method of Toxoplasma gondii oocysts from soil was evaluated using the sucrose flotation technique with modification involving addition of 0.1% gelatin into washing and floating solutions. PCR was performed on untreated samples and after treatment with polyvinylpyrrolidone (PVP), heating and cooling, and NaCl. The addition of gelatin in the sucrose solution yielded a higher number of oocysts. A very thin band was observed when DNA extract was diluted to 1:1024, indicating the presence of PCR inhibitor in the soil. PCR performed on untreated DNA, on PVP-treated, and on PVP-treated with heating and cooling without added bovine serum albumin (BSA) showed a band only at higher dilutions (1:1024 and 1:512) but at a much lower dilution (1:8) with BSA. In contrast, DNA treated with all three agents showed a band at a much lower dilution (1:64), even without added BSA, and no dilution was required when BSA was added. The PCR inhibitors present in the soil were removed by employing various treatment procedures during DNA extraction, and BSA in PCR. Furthermore, the detection limit with the method was 1 oocyst/g of soil, indicating that this method is useful in epidemiological studies.

  18. The effect of calcium hydroxide, alkali dilution and calcium concentration in mitigating the alkali silica reaction using palm oil fuel ash

    NASA Astrophysics Data System (ADS)

    Asrah, Hidayati; Mirasa, Abdul Karim; Bolong, Nurmin

    2018-02-01

    This study investigated the mechanism of how POFA mitigated the ASR expansion. Two types of POFA; the UPOFA and GPOFA with different fineness were used to replace the cement at 20% and 40% and their effects on the mortar bar expansion, calcium hydroxide, alkali dilution, and calcium concentration were investigated. The results showed that UPOFA has a significant ability to mitigate the ASR, even at a lower level of replacement (20%) compared to GPOFA. The mechanism of UPOFA in mitigating the ASR expansion was through a reduction in the calcium hydroxide content, which produced low calcium concentration within the mortar pore solution. Low pore solution alkalinity signified that UPOFA had good alkali dilution effect. Meanwhile, a higher dosage of GPOFA was required to mitigate the ASR expansion. An increase in the pore solution alkalinity of GPOFA mortar indicated higher penetration of alkalis from the NaOH solution, which reduced the alkali dilution effect. However, this was compensated by the increase in the cement dilution effect at higher GPOFA replacement, which controlled the mortar bar expansion below the ASTM limit.

  19. Ficts and facts of epinephrine and norepinephrine stability in injectable solutions.

    PubMed

    Hoellein, Ludwig; Holzgrabe, Ulrike

    2012-09-15

    Epinephrine (EPI) and norepinephrine (NE) play an important role in emergency medicine and acute treatment of hypotension and shocks in the intensive care unit. Injectable solutions can either be provided as proprietary medicinal products or as individually prepared dilutions. Due to the chemical structure of EPI and NE, the stability of the corresponding solutions is limited. Thus, most manufacturers of EPI and NE injectable solutions use sulfites and nitrogen for stabilization, Nevertheless, storage conditions such as temperature and light have to be considered, but are often neglected in the daily hospital routine. In addition, hospital pharmacies prepare EPI and NE solutions and dilute commercially available solutions for individual therapy, especially on ICUs. Since the influence of dilution and the presence of excipients and other preservatives are not systematically explored, we collected published data and investigations on stability on the potency of EPI and NE injectable solutions in order to deduce storage recommendations for diluted EPI and NE solutions of different concentration. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Consideration of some dilute-solution phenomena based on an expression for the Gibbs free energy

    NASA Astrophysics Data System (ADS)

    Jonah, D. A.

    1986-07-01

    Rigorous expressions based on the Lennard-Jones (6 12) potential, are presented for the Gibbs and Helmholtz free energy of a dilute mixture. These expressions give the free energy of the mixture in terms of the thermodynamic properties of the pure solvent, thereby providing a convenient means of correlating dilute mixture behavior with that of the pure solvent. Expressions for the following dilute binary solution properties are derived: Henry's constant, limiting activity coefficients with their derivatives, solid solubilities in supercritical gases, and mixed second virial coefficients. The Henry's constant expression suggests a linear temperature dependence; application to solubility data for various gases in methane and water shows a good agreement between theory and experiment. In the thermodynamic modeling of supercritical fluid extraction, we have demonstrated how to predict new solubility-pressure isotherms from a given isotherm, with encouraging results. The mixed second virial coefficient expression has also been applied to experimental data; the agreement with theory is good.

  1. Automatic tracer-dilution method used for stage-discharge ratings and streamflow hydrographs on small Iowa streams

    USGS Publications Warehouse

    Soenksen, P.J.

    1990-01-01

    Tracer-dilution discharge measurements were made during 14 flow periods at six stations from 1986 through 1988 water years. Ratings were developed at three stations with the aid of these measurements. A loop rating was identified at one station during rapidly-changing flow conditions. Incomplete mixing and dye loss to sediment apparently were problems at some stations. Stage hydrographs were recorded for 38 flows at seven stations. Limited data on background fluorescence during high flows were also obtained.

  2. Condensate statistics in interacting and ideal dilute bose gases

    PubMed

    Kocharovsky; Kocharovsky; Scully

    2000-03-13

    We obtain analytical formulas for the statistics, in particular, for the characteristic function and all cumulants, of the Bose-Einstein condensate in dilute weakly interacting and ideal equilibrium gases in the canonical ensemble via the particle-number-conserving operator formalism of Girardeau and Arnowitt. We prove that the ground-state occupation statistics is not Gaussian even in the thermodynamic limit. We calculate the effect of Bogoliubov coupling on suppression of ground-state occupation fluctuations and show that they are governed by a pair-correlation, squeezing mechanism.

  3. High accuracy method for the application of isotope dilution to gas chromatography/mass spectrometric analysis of gases.

    PubMed

    Milton, Martin J T; Wang, Jian

    2003-01-01

    A new isotope dilution mass spectrometry (IDMS) method for high-accuracy quantitative analysis of gases has been developed and validated by the analysis of standard mixtures of carbon dioxide in nitrogen. The method does not require certified isotopic reference materials and does not require direct measurements of the highly enriched spike. The relative uncertainty of the method is shown to be 0.2%. Reproduced with the permission of Her Majesty's Stationery Office. Copyright Crown copyright 2003.

  4. 40 CFR 86.527-90 - Test procedures, overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 86.527-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... constant volume (variable dilution) sampler. (d) Except in cases of component malfunction or failure, all... emissions measurements are made. For exhaust testing, this requires sampling and analysis of the dilution...

  5. Compositional analysis of dilute nitride doped indium antimonide bulk crystal by VDS technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, Manisha, E-mail: manishauj@gmail.com; Department of Physics, Mithibai College, Vile Parle; Maske, Dilip

    2016-05-06

    Dilute nitrides are suitable materials for fabrication of devices in detection of long wavelength infrared region. Dilute nitride doped Indium antimonide bulk crystals were grown using vertical directional solidification technique. The compositional characteristics of the crystals were carried out using EDS. The analysis was simulated and compared with observations using DTSA II software for accuracy. The ingots have uniform composition of Indium and Antimony. The actual nitrogen composition measured using EDS was 0.136% for doped nitrogen composition 0.1% except near conical end where it was 0.1%. The study of bonding between nitrogen, Indium and antimony was carried out using SIMS.more » The analysis shows strong presence of In-N bonding along with In-Sb bonds which indicates nitrogen has replaced antimony atoms in crystal lattice.« less

  6. [Formation of oxalate in oxaliplatin injection diluted with infusion solutions].

    PubMed

    Eto, Seiji; Yamamoto, Kie; Shimazu, Kounosuke; Sugiura, Toshimune; Baba, Kaori; Sato, Ayaka; Goromaru, Takeshi; Hagiwara, Yoshiaki; Hara, Keiko; Shinohara, Yoshitake; Takahashi, Kojiro

    2014-01-01

    Oxaliplatin use can cause acute peripheral neuropathy characterized by sensory paresthesias, which are markedly exacerbated by exposure to cold temperatures, and is a dose-limiting factor in the treatment of colorectal cancer.Oxalate is eliminated in a series of nonenzymatic conversions of oxaliplatin in infusion solutions or biological fluids.Elimination of oxalate from oxaliplatin has been suggested as one of the reasons for the development of acute neuropathy.In this study, we developed a high-performance liquid chromatography(HPLC)-based method to detect oxalate formation, and investigated the time dependent formation of oxalate in oxaliplatin diluted with infusion solutions.The results obtained showed that the amount of oxalate in the solution corresponded to 1.6% of oxaliplatin 8 h after oxaliplatin dilution with a 5% glucose solution. On the other hand, oxalate formation from oxaliplatin diluted with a saline solution was ten-fold higher than that from oxaliplatin diluted with the 5% glucose solution.Most patients who were intravenously injected with oxaliplatin experienced venous pain.As a preventive measure against venous pain, dexamethasone was added to the oxaliplatin injection.We measured the amount of oxalate formed in the dexamethasone-containing oxaliplatin injection diluted with a 5% glucose solution.The amount of oxalate formed when dexamethasone was added did not differ significantly from that formed when dexamethasone was not added.Thus, there are no clinical problems associated with the stability of oxaliplatin solutions.

  7. Cycling temperature capillary electrophoresis: A quantitative, fast and inexpensive method to detect mutations in mixed populations of human mitochondrial DNA.

    PubMed

    Refinetti, Paulo; Morgenthaler, Stephan; Ekstrøm, Per O

    2016-07-01

    Cycling temperature capillary electrophoresis has been optimised for mutation detection in 76% of the mitochondrial genome. The method was tested on a mixed sample and compared to mutation detection by next generation sequencing. Out of 152 fragments 90 were concordant, 51 discordant and in 11 were semi-concordant. Dilution experiments show that cycling capillary electrophoresis has a detection limit of 1-3%. The detection limit of routine next generation sequencing was in the ranges of 15 to 30%. Cycling temperature capillary electrophoresis detect and accurate quantify mutations at a fraction of the cost and time required to perform a next generation sequencing analysis. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Improved detection limits for electrospray ionization on a magnetic sector mass spectrometer by using an array detector.

    PubMed

    Cody, R B; Tamura, J; Finch, J W; Musselman, B D

    1994-03-01

    Array detection was compared with point detection for solutions of hen egg-white lysozyme, equine myoglobin, and ubiquitin analyzed by electrospray ionization with a magnetic sector mass spectrometer. The detection limits for samples analyzed by using the array detector system were at least 10 times lower than could be achieved by using a point detector on the same mass spectrometer. The minimum detectable quantity of protein corresponded to a signal-to-background ratio of approximately 2∶1 for a 500 amol/μL solution of hen egg-white lysozyme. However, the ultimate practical sample concentrations appeared to be in the 10-100 fmol/μL range for the analysis of dilute solutions of relatively pure proteins or simple mixtures.

  9. Determination of As concentration in earthworm coelomic fluid extracts by total-reflection X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Allegretta, Ignazio; Porfido, Carlo; Panzarino, Onofrio; Fontanella, Maria Chiara; Beone, Gian Maria; Spagnuolo, Matteo; Terzano, Roberto

    2017-04-01

    Earthworms are often used as sentinel organisms to study As bioavailability in polluted soils. Arsenic in earthworms is mainly sequestrated in the coelomic fluids whose As content can therefore be used to asses As bioavalability. In this work, a method for determining As concentration in coelomic fluid extracts using total-reflection X-ray fluorescence spectrometry (TXRF) is presented. For this purpose coelomic fluid extracts from earthworms living in three polluted soils and one non-polluted (control) soil have been collected and analysed. A very simple sample preparation was implemented, consisting of a dilution of the extracts with polyvinyl alcohol (PVA) using a 1:8 ratio and dropwise deposition of the sample on the reflector. A detection limit of 0.2 μg/l and quantification limit of 0.6 μg/l was obtained in the diluted samples, corresponding to 2 μg/l and 6 μg/l in the coelomic fluid extracts, respectively. This allowed to quantify As concentration in coelomic fluids extracted from earthworms living in soils polluted with As at concentrations higher than 20 mg/kg (considered as a pollution threshold for agricultural soils). The TXRF method has been validated by comparison with As concentrations in standards and by analysing the same samples by ICP-MS, after acid digestion of the sample. The low limit of detection, the proven reliability of the method and the little sample preparation make TXRF a suitable, cost-efficient and "green" technique for the analysis of As in earthworm coelomic fluid extracts for bioavailability studies.

  10. Regolith Volatile Characterization (RVC) in RESOLVE

    NASA Technical Reports Server (NTRS)

    Captain, Janine; Lueck, Dale; Gibson, Tracy; Levine, Lanfang

    2010-01-01

    Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

  11. Odorant Screening and Quantitation of Thiols in Carmenere Red Wine by Gas Chromatography-Olfactometry and Stable Isotope Dilution Assays.

    PubMed

    Pavez, Carolina; Agosin, Eduardo; Steinhaus, Martin

    2016-05-04

    The sensory impact of thiols in Vitis vinifera 'Carmenere' red wines was evaluated. For this purpose, aroma extract dilution analysis was applied to the thiols isolated from a Carmenere red wine by affinity chromatography with a mercurated agarose gel. Results revealed the presence of four odorants, identified as 2-furanylmethanethiol, 3-sulfanylhexyl acetate, 3-sulfanyl-1-hexanol, and 2-methyl-3-sulfanyl-1-butanol, with the latter being described here for the first time in Carmenere red wines. Quantitation of the four thiols in the Carmenere wine screened by aroma extract dilution analysis and in three additional Carmenere wines by stable isotope dilution assays resulted in concentrations above the respective orthonasal odor detection threshold values. Triangle tests applied to wine model solutions with and without the addition of the four thiols showed significant differences, thus suggesting that the compounds do have the potential to influence the overall aroma of red wine.

  12. Analysis of gas membrane ultra-high purification of small quantities of mono-isotopic silane

    DOE PAGES

    de Almeida, Valmor F.; Hart, Kevin J.

    2017-01-03

    A small quantity of high-value, crude, mono-isotopic silane is a prospective gas for a small-scale, high-recovery, ultra-high membrane purification process. This is an unusual application of gas membrane separation for which we provide a comprehensive analysis of a simple purification model. The goal is to develop direct analytic expressions for estimating the feasibility and efficiency of the method, and guide process design; this is only possible for binary mixtures of silane in the dilute limit which is a somewhat realistic case. In addition, analytic solutions are invaluable to verify numerical solutions obtained from computer-aided methods. Hence, in this paper wemore » provide new analytic solutions for the purification loops proposed. Among the common impurities in crude silane, methane poses a special membrane separation challenge since it is chemically similar to silane. Other potential problematic compounds are: ethylene, diborane and ethane (in this order). Nevertheless, we demonstrate, theoretically, that a carefully designed membrane system may be able to purify mono-isotopic, crude silane to electronics-grade level in a reasonable amount of time and expenses. We advocate a combination of membrane materials that preferentially reject heavy impurities based on mobility selectivity, and light impurities based on solubility selectivity. We provide estimates for the purification of significant contaminants of interest. In this study, we suggest cellulose acetate and polydimethylsiloxane as examples of membrane materials on the basis of limited permeability data found in the open literature. We provide estimates on the membrane area needed and priming volume of the cell enclosure for fabrication purposes when using the suggested membrane materials. These estimates are largely theoretical in view of the absence of reliable experimental data for the permeability of silane. And finally, future extension of this work to the non-dilute limit may apply to the recovery of silane from rejected streams of natural silicon semi-conductor processes.« less

  13. Analysis of gas membrane ultra-high purification of small quantities of mono-isotopic silane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Almeida, Valmor F.; Hart, Kevin J.

    A small quantity of high-value, crude, mono-isotopic silane is a prospective gas for a small-scale, high-recovery, ultra-high membrane purification process. This is an unusual application of gas membrane separation for which we provide a comprehensive analysis of a simple purification model. The goal is to develop direct analytic expressions for estimating the feasibility and efficiency of the method, and guide process design; this is only possible for binary mixtures of silane in the dilute limit which is a somewhat realistic case. In addition, analytic solutions are invaluable to verify numerical solutions obtained from computer-aided methods. Hence, in this paper wemore » provide new analytic solutions for the purification loops proposed. Among the common impurities in crude silane, methane poses a special membrane separation challenge since it is chemically similar to silane. Other potential problematic compounds are: ethylene, diborane and ethane (in this order). Nevertheless, we demonstrate, theoretically, that a carefully designed membrane system may be able to purify mono-isotopic, crude silane to electronics-grade level in a reasonable amount of time and expenses. We advocate a combination of membrane materials that preferentially reject heavy impurities based on mobility selectivity, and light impurities based on solubility selectivity. We provide estimates for the purification of significant contaminants of interest. In this study, we suggest cellulose acetate and polydimethylsiloxane as examples of membrane materials on the basis of limited permeability data found in the open literature. We provide estimates on the membrane area needed and priming volume of the cell enclosure for fabrication purposes when using the suggested membrane materials. These estimates are largely theoretical in view of the absence of reliable experimental data for the permeability of silane. And finally, future extension of this work to the non-dilute limit may apply to the recovery of silane from rejected streams of natural silicon semi-conductor processes.« less

  14. Analysis of Gas Membrane Ultra-High Purification of Small Quantities of Mono-Isotopic Silane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Almeida, Valmor F.; Hart, Kevin J.

    A small quantity of high-value, crude, mono-isotopic silane is a prospective gas for a small-scale, high-recovery, ultra-high membrane purification process. This is an unusual application of gas membrane separation for which we provide a comprehensive analysis of a simple purification model. The goal is to develop direct analytic expressions for estimating the feasibility and efficiency of the method, and guide process design; this is only possible for binary mixtures of silane in the dilute limit which is a somewhat realistic case. Among the common impurities in crude silane, methane poses a special membrane separation challenge since it is chemically similarmore » to silane. Other potential problematic surprises are: ethylene, diborane and ethane (in this order). Nevertheless, we demonstrate, theoretically, that a carefully designed membrane system may be able to purify mono-isotopic, crude silane to electronics-grade level in a reasonable amount of time and expenses. We advocate a combination of membrane materials that preferentially reject heavy impurities based on mobility selectivity, and light impurities based on solubility selectivity. We provide estimates for the purification of significant contaminants of interest. To improve the separation selectivity, it is advantageous to use a permeate chamber under vacuum, however this also requires greater control of in-leakage of impurities in the system. In this study, we suggest cellulose acetate and polydimethylsiloxane as examples of membrane materials on the basis of limited permeability data found in the open literature. We provide estimates on the membrane area needed and priming volume of the cell enclosure for fabrication purposes when using the suggested membrane materials. These estimates are largely theoretical in view of the absence of reliable experimental data for the permeability of silane. Last but not least, future extension of this work to the non-dilute limit may apply to the recovery of silane from rejected streams of natural silicon semi-conductor processes.« less

  15. Sensitive determination of anions in saliva using capillary electrophoresis after transient isotachophoretic preconcentration.

    PubMed

    Xu, Zhongqi; Doi, Takayuki; Timerbaev, Andrei R; Hirokawa, Takeshi

    2008-10-19

    A transient isotachophoresis-capillary electrophoresis (tITP-CE) system for the determination of minor inorganic anions in saliva is described. The complete separation and quantification of bromide, iodide, nitrate, nitrite, and thiocyanate has been achieved with only centrifugation and dilution of the saliva sample. In-line tITP preconcentration conditions, created by introduction of the plugs of 5 mM dithionic acid (leading electrolyte) and 10 mM formic acid (terminating electrolyte) before and after the sample zone, respectively, allowed the limits of direct UV absorption detection (at 200 nm) to be up to 50-fold improved as compared with CE without tITP. As a result, nitrate and thiocyanate were still detectable at 4.6 and 3.8 microgl(-1), respectively, in 1000 times diluted saliva. The daily variations of anionic concentrations in saliva samples taken from a smoking health volunteer were discussed based on the results of tITP-CE analysis. It was confirmed that the thiocyanate concentration in saliva noticeably increased after smoking. This is apparently the first report on simultaneous quantification of more than four anionic salivary constituents using CE.

  16. Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements.

    PubMed Central

    Mihm, F G; Feeley, T W; Jamieson, S W

    1987-01-01

    The thermal dye double indicator dilution technique for estimating lung water was compared with gravimetric analyses in nine human subjects who were organ donors. As observed in animal studies, the thermal dye measurement of extravascular thermal volume (EVTV) consistently overestimated gravimetric extravascular lung water (EVLW), the mean (SEM) difference being 3.43 (0.59) ml/kg. In eight of the nine subjects the EVTV -3.43 ml/kg would yield an estimate of EVLW that would be from 3.23 ml/kg under to 3.37 ml/kg over the actual value EVLW at the 95% confidence limits. Reproducibility, assessed with the standard error of the mean percentage, suggested that a 15% change in EVTV can be reliably detected with repeated measurements. One subject was excluded from analysis because the EVTV measurement grossly underestimated its actual EVLW. This error was associated with regional injury observed on gross examination of the lung. Experimental and clinical evidence suggest that the thermal dye measurement provides a reliable estimate of lung water in diffuse pulmonary oedema states. PMID:3616974

  17. Microfiltration: Effect of retentate protein concentration on limiting flux and serum protein removal with 4-mm-channel ceramic microfiltration membranes.

    PubMed

    Hurt, E E; Adams, M C; Barbano, D M

    2015-04-01

    The objective of our study was to determine if the limiting flux and serum protein (SP) removal were different at 8, 9, or 10% true protein (TP) in the microfiltration (MF) retentate recirculation loop using 0.1-µm ceramic graded permeability membranes with 4-mm-channel diameters operated at 50 °C using a diluted milk protein concentrate with 85% protein on a total solids basis (MPC85) as the MF feed. The limiting flux for the MF of diluted MPC85 was determined at 3 TP concentrations in the recirculation loop (8, 9, and 10%). The experiment was replicated 3 times for a total of 9 runs. On the morning of each run, MPC85 was diluted with reverse osmosis water to an MF feed TP concentration of 5.4%. In all runs, the starting flux was 55 kg/m(2) per hour, the flux was increased in steps until the limiting flux was reached. The minimum flux increase was 10 kg/m(2) per hour. The limiting flux decreased as TP concentration in the recirculation loop increased. The limiting flux was 154 ± 0.3, 133 ± 0.7, and 117 ± 3.3 kg/m(2) per hour at recirculation loop TP concentrations of 8.2 ± 0.07, 9.2 ± 0.04, and 10.2 ± 0.09%, respectively. No effect of recirculation loop TP concentration on the SP removal factor was detected. However, the SP removal factor decreased from 0.80 ± 0.02 to 0.75 ± 0.02 as flux was increased from the starting flux of 55 kg/m(2) per hour to the limiting flux, with a similar decrease seen at all recirculation loop TP concentrations. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. The geochemical evolution of aqueous sodium in the Black Creek Aquifer, Horry and Georgetown counties, South Carolina

    USGS Publications Warehouse

    Zack, Allen L.; Roberts, Ivan

    1988-01-01

    The Black Creek aquifer contains dilute seawater near the North Carolina State line, probably the result of incomplete flushing of ancient seawater. Data do not indicate that the dilute seawater has migrated toward areas of fresh ground-water withdrawals. The concentration of chloride in ground-water samples ranges from 5 to 720 milligrams per liter and that of sodium from 160 to 690 milligrams per liter. Ion-exchange reactions (sodium for calcium and fluoride for hydroxyl) occur with the calcium carbonate dissolution reaction which produces calcium, bicarbonate, and hydroxyl ions. The reaction sequence and stoichiometry result in an aqueous solution in which the sum of bicarbonate and chloride equivalents per liter is equal to the equivalents per liter of sodium. Calcium ions are exchanged for sodium ions derived from sodium-rich clays upgradient of the dilute seawater. The cation-exchange reaction equilibrates at a sodium concentration of 280 milligrams per liter. Amounts of sodium greater than 280 milligrams per liter are contributed from dilute seawater. The cation-exchange reaction approaches an equilibrium which represents a mass-action limit in terms of the ratio of sodium to calcium in solution versus the ratio of exchangeable sodium to calcium on clay surfaces. Where the limit of calcium carbonate solubility is approached and dissolution ceases, some precipitation of calcite probably takes place. The dissolution of calcite exposes fossil shark teeth which release fluoride ions to the ground water through anion exchange with aqueous hydroxyl ions.

  19. A method for predicting optimized processing parameters for surfacing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dupont, J.N.; Marder, A.R.

    1994-12-31

    Welding is used extensively for surfacing applications. To operate a surfacing process efficiently, the variables must be optimized to produce low levels of dilution with the substrate while maintaining high deposition rates. An equation for dilution in terms of the welding variables, thermal efficiency factors, and thermophysical properties of the overlay and substrate was developed by balancing energy and mass terms across the welding arc. To test the validity of the resultant dilution equation, the PAW, GTAW, GMAW, and SAW processes were used to deposit austenitic stainless steel onto carbon steel over a wide range of parameters. Arc efficiency measurementsmore » were conducted using a Seebeck arc welding calorimeter. Melting efficiency was determined based on knowledge of the arc efficiency. Dilution was determined for each set of processing parameters using a quantitative image analysis system. The pertinent equations indicate dilution is a function of arc power (corrected for arc efficiency), filler metal feed rate, melting efficiency, and thermophysical properties of the overlay and substrate. With the aid of the dilution equation, the effect of processing parameters on dilution is presented by a new processing diagram. A new method is proposed for determining dilution from welding variables. Dilution is shown to depend on the arc power, filler metal feed rate, arc and melting efficiency, and the thermophysical properties of the overlay and substrate. Calculated dilution levels were compared with measured values over a large range of processing parameters and good agreement was obtained. The results have been applied to generate a processing diagram which can be used to: (1) predict the maximum deposition rate for a given arc power while maintaining adequate fusion with the substrate, and (2) predict the resultant level of dilution with the substrate.« less

  20. Disentangling niche competition from grazing mortality in phytoplankton dilution experiments

    PubMed Central

    Weitz, Joshua S.

    2017-01-01

    The dilution method is the principal tool used to infer in situ microzooplankton grazing rates. However, grazing is the only mortality process considered in the theoretical model underlying the interpretation of dilution method experiments. Here we evaluate the robustness of mortality estimates inferred from dilution experiments when there is concurrent niche competition amongst phytoplankton. Using a combination of mathematical analysis and numerical simulations, we find that grazing rates may be overestimated—the degree of overestimation is related to the importance of niche competition relative to microzooplankton grazing. In response, we propose a conceptual method to disentangle the effects of niche competition and grazing by diluting out microzooplankton, but not phytoplankton. Our theoretical results suggest this revised “Z-dilution” method can robustly infer grazing mortality, regardless of the dominant phytoplankton mortality driver in our system. Further, we show it is possible to independently estimate both grazing mortality and niche competition if the classical and Z-dilution methods can be used in tandem. We discuss the significance of these results for quantifying phytoplankton mortality rates; and the feasibility of implementing the Z-dilution method in practice, whether in model systems or in complex communities with overlap in the size distributions of phytoplankton and microzooplankton. PMID:28505212

  1. Interactive effect of warming, nitrogen and phosphorus limitation on phytoplankton cell size

    PubMed Central

    Peter, Kalista Higini; Sommer, Ulrich

    2015-01-01

    Cell size is one of the ecologically most important traits of phytoplankton. The cell size variation is frequently related to temperature and nutrient limitation. In order to disentangle the role of both factors, an experiment was conducted to determine the possible interactions of these factors. Baltic Sea water containing the natural plankton community was used. We performed a factorial combined experiment of temperature, type of nutrient limitation (N vs. P), and strength of nutrient limitation. The type of nutrient limitation was manipulated by altering the N:P ratio of the medium (balanced, N and P limitation) and strength by the dilution rate (0% and 50%) of the semicontinuous cultures. The negative effect of temperature on cell size was strongest under N limitation, intermediate under P limitation, and weakest when N and P were supplied at balanced ratios. However, temperature also influenced the intensity of nutrient imitation, because at higher temperature there was a tendency for dissolved nutrient concentrations to be lower, while the C:N or C:P ratio being higher…higher at identical dilution rates and medium composition. Analyzing the response of cell size to C:N ratios (as index of N limitation) and C:P ratios (as index of P limitation) indicated a clear dominance of the nutrient effect over the direct temperature effect, although the temperature effect was also significant. PMID:25798219

  2. [Diagnostic contribution of abnormal delayed-type hypersensitivity to Candida albicans. Characterization test by activation of cells sensitized to successive dilutions of Candida].

    PubMed

    Brunet, J L; Cozon, G; Sainte-Laudy, J; Boissel, J P; Delair, S; Peyramond, D

    1997-10-01

    By measuring the activation of different cell models (lymphocytes and lymphocytic subsets) in the presence of Candida albicans with flow cytometry reading, it is possible to show that successive dilutions of Candida albicans can lead to lymphocyte activation in abnormally-sensitized subjects. In a first trial, 10 subjects were tested in duplicate. The decrease of activity of the dilutions does not appear to be regular in relation to the progression of the dilutions. The activity of the dilutions wanes relatively rapidly with the first dilutions, then recurs later very distinctly, at the 6th dilution, then ebbs, then reappears in similar manner at the 9th, the 14th, and finally, the 19th dilution. Cell reactivity appears to differ depending on the subject. It can be represented through the calculated slope of the regression line, for each series of data. It therefore appears feasible to determine a threshold of reactivity and a scale of sensitivity, to make it possible to specify the degree of abnormal reactivity existing at a given time for a given subject. The constancy of the activity of the different dilutions tested, on 10 cultures of a single cell suspension, is especially well demonstrated in the second trial, showing unusually small standard deviations. Thus, the question arises as to the exact nature of the observed phenomenon and of its analysis from a physical-chemical point of view, with regard to the pharmacological effect of successive dilutions of Candida albicans.

  3. Determination of copper by isotopic dilution.

    PubMed

    Faquim, E S; Munita, C S

    1994-01-01

    A rapid and selective method was used for the determination of copper by isotopic dilution employing substoichiometric extraction with dithizone in carbon tetrachloride. The appropriate pH range for the substoichiometric extraction was 2-7. In the analysis, even a large excess of elements forming extractable complexes with dithizone does not interfere. The accuracy and precision of the method were evaluated. The method has been applied to analysis of reference materials, wheat flour, wine, and beer.

  4. Determination of glucose and ethanol after enzymatic hydrolysis and fermentation of biomass using Raman spectroscopy.

    PubMed

    Shih, Chien-Ju; Smith, Emily A

    2009-10-27

    Raman spectroscopy has been used for the quantitative determination of the conversion efficiency at each step in the production of ethanol from biomass. The method requires little sample preparation; therefore, it is suitable for screening large numbers of biomass samples and reaction conditions in a complex sample matrix. Dilute acid or ammonia-pretreated corn stover was used as a model biomass for these studies. Ammonia pretreatment was suitable for subsequent measurements with Raman spectroscopy, but dilute acid-pretreated corn stover generated a large background signal that surpassed the Raman signal. The background signal is attributed to lignin, which remains in the plant tissue after dilute acid pretreatment. A commercial enzyme mixture was used for the enzymatic hydrolysis of corn stover, and glucose levels were measured with a dispersive 785 nm Raman spectrometer. The glucose detection limit in hydrolysis liquor by Raman spectroscopy was 8 g L(-1). The mean hydrolysis efficiency for three replicate measurements obtained with Raman spectroscopy (86+/-4%) was compared to the result obtained using an enzymatic reaction with UV-vis spectrophotometry detection (78+/-8%). The results indicate good accuracy, as determined using a Student's t-test, and better precision for the Raman spectroscopy measurement relative to the enzymatic detection assay. The detection of glucose in hydrolysis broth by Raman spectroscopy showed no spectral interference, provided the sample was filtered to remove insoluble cellulose prior to analysis. The hydrolysate was further subjected to fermentation to yield ethanol. The detection limit for ethanol in fermentation broth by Raman spectroscopy was found to be 6 g L(-1). Comparison of the fermentation efficiencies measured by Raman spectroscopy (80+/-10%) and gas chromatography-mass spectrometry (87+/-9%) were statistically the same. The work demonstrates the utility of Raman spectroscopy for screening the entire conversion process to generate lignocellulosic ethanol.

  5. Comparison of candidate vCJD in vitro diagnostic assays using identical sample sets.

    PubMed

    Cooper, J K; Ladhani, K; Minor, P

    2012-02-01

    With four transfusion related transmissions of variant Creutzfeldt-Jakob Disease (vCJD), three of which developed clinical disease and the other died of other causes but was positive for markers of infection, there is an increased urgency to identify and implement a test for blood donor screening. With limited amounts of blood samples from vCJD cases available test evaluation is challenging. Alternative approaches are therefore needed. Control and vCJD tissues homogenates, where levels of markers of infectivity are known, were sequentially diluted in pooled human plasma. Identical sets of samples were provided blind to research groups developing diagnostic tests for vCJD; identical sample sets allows for direct comparisons of sensitivity to be made. Control and vCJD tissue homogenates were sequentially diluted in pooled human plasma (detergent solvent treated or cryo-depleted) supplied by commercial fractionators. Dilutions of vCJD tissues were within and beyond the limits of detection previously determined by the conformation-dependent immunoassay (Cooper et al.: Vox Sang 2007;92:302-310; Bellon et al.: J Gen Virol 2003;84: 1921-1925). A number of methods were used for the analysis of the blinded panels; with background signal from the normal prion protein (PrP) being removed by digestion with proteinase, epitope protection or selective capture of PrP(tse). Assay sensitivities were directly compared using identical sample sets. This approach identified several transmissible spongiform encephalopathies (TSE) diagnostic tests, based on different principles, high in analytical sensitivity that reproducibly detected markers of vCJD infectivity in tissue homogenates. The approach outlined has successfully compared in vitro diagnostics assays for their sensitivity and reproducibility and is a first step toward the evaluation of an assay suitable for blood donor screening/diagnosis of vCJD. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.

  6. Identification and Quantitation of Potent Odorants in Spearmint Oils.

    PubMed

    Kelley, Lauren E; Cadwallader, Keith R

    2018-03-14

    Potent odorants in Native spearmint, Scotch spearmint, and Macho mint oils were determined by the combined use of gas chromatography-olfactometry (GCO), gas chromatography-mass spectrometry (GC-MS), and aroma extract dilution analysis (AEDA). Of the 85 odorants detected, ( R)-(-)-carvone was the most potent odorant in all three spearmint oils. Additional predominant odorants in all spearmint oils included eugenol, ethyl ( S)-(+)-2-methylbutanoate, ( E)-β-damascenone, and (3 E,5 Z)-1,3,5-undecatriene. Forty-six compounds were quantitated using various methods, including 19 by gas chromatography with flame ionization detection (GC-FID), 20 by stable isotope dilution analysis (SIDA), and 14 by GCO dilution analysis. Concentrations were used to calculate the odor activity values (OAVs) for predominant odorants in the oils. Among the compounds quantitated, those with the highest OAVs were ( R)-(-)-carvone, 1,8-cineole, ( E, Z)-2,6-nonadienal, ( E)-β-damascenone, and (3 E,5 Z)-1,3,5-undecatriene.

  7. A symmetrical method to obtain shear moduli from microrheology.

    PubMed

    Nishi, Kengo; Kilfoil, Maria L; Schmidt, Christoph F; MacKintosh, F C

    2018-05-16

    Passive microrheology typically deduces shear elastic loss and storage moduli from displacement time series or mean-squared displacements (MSD) of thermally fluctuating probe particles in equilibrium materials. Common data analysis methods use either Kramers-Kronig (KK) transformation or functional fitting to calculate frequency-dependent loss and storage moduli. We propose a new analysis method for passive microrheology that avoids the limitations of both of these approaches. In this method, we determine both real and imaginary components of the complex, frequency-dependent response function χ(ω) = χ'(ω) + iχ''(ω) as direct integral transforms of the MSD of thermal particle motion. This procedure significantly improves the high-frequency fidelity of χ(ω) relative to the use of KK transformation, which has been shown to lead to artifacts in χ'(ω). We test our method on both model and experimental data. Experiments were performed on solutions of worm-like micelles and dilute collagen solutions. While the present method agrees well with established KK-based methods at low frequencies, we demonstrate significant improvement at high frequencies using our symmetric analysis method, up to almost the fundamental Nyquist limit.

  8. Effects of Time and Storage Conditions on the Chemical and Microbiologic Stability of Diluted Buprenorphine for Injection

    PubMed Central

    DenHerder, Johnathan M; Reed, Ralph L; Sargent, Jennifer L; Bobe, Gerd; Stevens, Jan F; Diggs, Helen E

    2017-01-01

    Buprenorphine is a partial μ-opioid agonist used for analgesia. Due to the small size of laboratory rodents, buprenorphine HCl is typically diluted 10- or 20-fold with a sterile diluent, such as saline, for accurate dosing. Protocols for preparing and storing diluted buprenorphine vary by institution, and little published information is available regarding stability and beyond-use dating of specific buprenorphine preparations. The purpose of this study was to determine the chemical and microbiologic stability of diluted buprenorphine stored for a maximum of 180 d. Buprenorphine HCl was diluted 1:10 into sterile bacteriostatic saline by using aseptic technique. Diluted samples were stored in glass vials or plastic syringes, protected from light, and maintained at refrigerated or room temperature for as long as 180 d. Aerobic and anaerobic cultures on all stored samples were negative for bacterial and fungal growth. According to HPLC analysis, diluted buprenorphine stored in glass vials experienced less than 10% loss when stored for 180 d at either refrigerated or room temperature. However, the concentration of buprenorphine stored in syringes declined rapidly to more than 80% loss at room temperature and 28% loss in the refrigerator after 180 d. According to the results of this study, diluted buprenorphine stored in glass vials retains more than 90% of the initial concentration and is microbiologically stable for 180 d. However, our data suggest that, regardless of the duration, storing diluted buprenorphine in plastic syringes is inadvisable. PMID:28724496

  9. Validation of bioelectrical impedance analysis in Ethiopian adults with HIV.

    PubMed

    Hegelund, Maria H; Wells, Jonathan C; Girma, Tsinuel; Faurholt-Jepsen, Daniel; Zerfu, Dilnesaw; Christensen, Dirk L; Friis, Henrik; Olsen, Mette F

    2017-01-01

    Bioelectrical impedance analysis (BIA) is an inexpensive, quick and non-invasive method to determine body composition. Equations used in BIA are typically derived in healthy individuals of European descent. BIA is specific to health status and ethnicity and may therefore provide inaccurate results in populations of different ethnic origin and health status. The aim of the present study was to test the validity of BIA in Ethiopian antiretroviral-naive HIV patients. BIA was validated against the 2 H dilution technique by comparing fat-free mass (FFM) measured by the two methods using paired t tests and Bland-Altman plots. BIA was based on single frequency (50 kHz) whole-body measurements. Data were obtained at three health facilities in Jimma Zone, Oromia Region, South-West Ethiopia. Data from 281 HIV-infected participants were available. Two-thirds were female and the mean age was 32·7 (sd 8·6) years. Also, 46 % were underweight with a BMI below 18·5 kg/m 2 . There were no differences in FFM between the methods. Overall, BIA slightly underestimated FFM by 0·1 kg (-0·1, 95 % CI -0·3, 0·2 kg). The Bland-Altman plot indicated acceptable agreement with an upper limit of agreement of 4·5 kg and a lower limit of agreement of -4·6 kg, but with a small correlation between the mean difference and the average FFM. BIA slightly overestimated FFM at low values compared with the 2 H dilution technique, while it slightly underestimated FFM at high values. In conclusion, BIA proved to be valid in this population and may therefore be useful for measuring body composition in routine practice in HIV-infected African individuals.

  10. Presence of the Corexit component dioctyl sodium sulfosuccinate in Gulf of Mexico waters after the 2010 Deepwater Horizon oil spill

    USGS Publications Warehouse

    Gray, James L.; Kanagy, Leslie K.; Furlong, Edward T.; Kanagy, Chris J.; McCoy, Jeff W.; Mason, Andrew; Lauenstein, Gunnar

    2014-01-01

    Between April 22 and July 15, 2010, approximately 4.9 million barrels of oil were released into the Gulf of Mexico from the Deepwater Horizon oil well. Approximately 16% of the oil was chemically dispersed, at the surface and at 1500 m depth, using Corexit 9527 and Corexit 9500, which contain dioctyl sodium sulfosuccinate (DOSS) as a major surfactant component. This was the largest documented release of oil in history at substantial depth, and the first time large quantities of dispersant (0.77 million gallons of approximately 1.9 million gallons total) were applied to a subsurface oil plume. During two cruises in late May and early June, water samples were collected at the surface and at depth for DOSS analysis. Real-time fluorimetry data was used to infer the presence of oil components to select appropriate sampling depths. Samples were stored frozen and in the dark for approximately 6 months prior to analysis by liquid chromatography/tandem mass spectrometry with isotope-dilution quantification. The blank-limited method detection limit (0.25 μg L−1) was substantially less than the U.S. Environmental Protection Agency’s (USEPA) aquatic life benchmark of 40 μg L−1. Concentrations of DOSS exceeding 200 μg L−1 were observed in one surface sample near the well site; in subsurface samples DOSS did not exceed 40 μg L−1. Although DOSS was present at high concentration in the immediate vicinity of the well where it was being continuously applied, a combination of biodegradation, photolysis, and dilution likely reduced persistence at concentrations exceeding the USEPA aquatic life benchmark beyond this immediate area.

  11. Observations on the action of limit dextrinases on amylopectin-like polysaccharides (Short Communication)

    PubMed Central

    Dunn, Graham; Hardie, D. Grahame; Manners, David J.

    1973-01-01

    The rate of hydrolysis of amylopectin by three different limit dextrinase preparations is only about 15–23% of that of amylopectin β-limit dextrin under similar conditions. On dilution of the enzymes there was no change in specificity. The factors controlling the specificity of the enzyme and the possible significance in vivo of the results are discussed. PMID:4734116

  12. Exploration of oxide-based diluted magnetic semiconductors toward transparent spintronics

    NASA Astrophysics Data System (ADS)

    Fukumura, T.; Yamada, Y.; Toyosaki, H.; Hasegawa, T.; Koinuma, H.; Kawasaki, M.

    2004-02-01

    A review is given for the recent progress of research in the field of oxide-based diluted magnetic semiconductor (DMS), which was triggered by combinatorial discovery of transparent ferromagnet. The possible advantages of oxide semiconductor as a host of DMS are described in comparison with conventional compound semiconductors. Limits and problems for identifying novel ferromagnetic DMS are described in view of recent reports in this field. Several characterization techniques are proposed in order to eliminate unidentified ferromagnetism of oxide-based DMS unidentified ferromagnetic oxide (UFO). Perspectives and possible devices are also given.

  13. Does Marcus-Hush theory really work Optical studies of intervalence transfer in acetylene-bridged biferrocene monocation at infinite dilution and at finite ionic strengths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackbourn, R.L.; Hupp, J.T.

    1990-03-08

    Intervalence charge-transfer data for acetylene-bridged biferrocene monocation (Bf{sup +}) have been collected in five solvents in the presence and absence of excess electrolyte and in the limit of infinite chromophore dilution. The study was motivated by earlier work which demonstrated that the intervalence absorption maximum for Bf{sup +} in methylene chloride could vary substantially with both chromophore concentration and added electrolyte concentration. In the present study similar (but smaller) variations are found in other solvents.

  14. Droplet Microarray Based on Superhydrophobic-Superhydrophilic Patterns for Single Cell Analysis.

    PubMed

    Jogia, Gabriella E; Tronser, Tina; Popova, Anna A; Levkin, Pavel A

    2016-12-09

    Single-cell analysis provides fundamental information on individual cell response to different environmental cues and is a growing interest in cancer and stem cell research. However, current existing methods are still facing challenges in performing such analysis in a high-throughput manner whilst being cost-effective. Here we established the Droplet Microarray (DMA) as a miniaturized screening platform for high-throughput single-cell analysis. Using the method of limited dilution and varying cell density and seeding time, we optimized the distribution of single cells on the DMA. We established culturing conditions for single cells in individual droplets on DMA obtaining the survival of nearly 100% of single cells and doubling time of single cells comparable with that of cells cultured in bulk cell population using conventional methods. Our results demonstrate that the DMA is a suitable platform for single-cell analysis, which carries a number of advantages compared with existing technologies allowing for treatment, staining and spot-to-spot analysis of single cells over time using conventional analysis methods such as microscopy.

  15. Detailed mechanism of benzene oxidation

    NASA Technical Reports Server (NTRS)

    Bittker, David A.

    1987-01-01

    A detailed quantitative mechanism for the oxidation of benzene in both argon and nitrogen diluted systems is presented. Computed ignition delay time for argon diluted mixtures are in satisfactory agreement with experimental results for a wide range of initial conditions. An experimental temperature versus time profile for a nitrogen diluted oxidation was accurately matched and several concentration profiles were matched qualitatively. Application of sensitivity analysis has given approximate rate constant expressions for the two dominant heat release reactions, the oxidation of C6H5 and C5H5 radicals by molecular oxygen.

  16. Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    PubMed

    Sun, Phillip Zhe; Wang, Yu; Dai, ZhuoZhi; Xiao, Gang; Wu, Renhua

    2014-01-01

    Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitative CEST (qCEST) analysis. Towards this goal, it has been shown that omega plot is capable of quantifying paramagnetic CEST MRI. However, the use of the omega plot is somewhat limited for diamagnetic CEST (DIACEST) MRI because it is more susceptible to direct radio frequency (RF) saturation (spillover) owing to the relatively small chemical shift. Recently, it has been found that, for dilute DIACEST agents that undergo slow to intermediate chemical exchange, the spillover effect varies little with the labile proton ratio and exchange rate. Therefore, we postulated that the omega plot analysis can be improved if RF spillover effect could be estimated and taken into account. Specifically, simulation showed that both labile proton ratio and exchange rate derived using the spillover effect-corrected omega plot were in good agreement with simulated values. In addition, the modified omega plot was confirmed experimentally, and we showed that the derived labile proton ratio increased linearly with creatine concentration (p < 0.01), with little difference in their exchange rate (p = 0.32). In summary, our study extends the conventional omega plot for quantitative analysis of DIACEST MRI. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Use of ATP to characterize biomass viability in freely suspended and immobilized cell bioreactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gikas, P.; Livingston, A.G.

    1993-12-01

    This work describes investigations into the viability of cells growing on 3,4-dichloroaniline (34DCA). Two bio-reactors are employed for microbial growth, a continuous stirred tank (CST) bioreactor with a 2-L working volume, and a three-phase air lift (TPAL) bioreactor with a 3-L working volume. Experiments have been performed at several dilution rates between 0.027 and 0.115 h[sup [minus]1] in the CST bioreactor and between 0.111 and 0.500h[sup [minus]1] in the TPAL bioreactor. The specific ATP concentration was calculated at each dilution rate in the suspended biomass in both bioreactors as well as in the immobilized biomass in the TPAL bioreactor. Themore » cultures were inspected under an electron microscope to monitor compositional changes. Results from the CST bioreactor showed that the biomass-specific ATP concentration increases from 0.44 to 1.86 mg ATP g[sup [minus]1] dry weight (dw) as dilution rate increases from 0.027 to 0.115 h[sup [minus]1]. At this upper dilution rate the cells were washed out. The specific ATP concentration reached a limiting average value of 1.73 mg ATP g[sup [minus]1] dw, which is assumed to be the quantity of ATP in 100% viable biomass, In the TPAL bioreactor, the ATP level increased with dilution rat in both the immobilized and suspended biomass. The specific ATP concentration in the immobilized biomass increased from approximately 0.051 mg ATP g[sup [minus]1] dw at dilution rates between 0.111 and 0.200 h[sup [minus]1] to approximately 0.119 mg ATP g[sup [minus]1] dw at dilution rates between 0.300 and 0.500 h[sup [minus]1].« less

  18. Predicting solubilisation features of ternary phase diagrams of fully dilutable lecithin linker microemulsions.

    PubMed

    Nouraei, Mehdi; Acosta, Edgar J

    2017-06-01

    Fully dilutable microemulsions (μEs), used to design self-microemulsifying delivery system (SMEDS), are formulated as concentrate solutions containing oil and surfactants, without water. As water is added to dilute these systems, various μEs are produced (water-swollen reverse micelles, bicontinuous systems, and oil-swollen micelles), without the onset of phase separation. Currently, the formulation dilutable μEs follows a trial and error approach that has had a limited success. The objective of this work is to introduce the use of the hydrophilic-lipophilic-difference (HLD) and net-average-curvature (NAC) frameworks to predict the solubilisation features of ternary phase diagrams of lecithin-linker μEs and the use of these predictions to guide the formulation of dilutable μEs. To this end, the characteristic curvatures (Cc) of soybean lecithin (surfactant), glycerol monooleate (lipophilic linker) and polyglycerol caprylate (hydrophilic linker) and the equivalent alkane carbon number (EACN) of ethyl caprate (oil) were obtained via phase scans with reference surfactant-oil systems. These parameters were then used to calculate the HLD of lecithin-linkers-ethyl caprate microemulsions. The calculated HLDs were able to predict the phase transitions observed in the phase scans. The NAC was then used to fit and predict phase volumes obtained from salinity phase scans, and to predict the solubilisation features of ternary phase diagrams of the lecithin-linker formulations. The HLD-NAC predictions were reasonably accurate, and indicated that the largest region for dilutable μEs was obtained with slightly negative HLD values. The NAC framework also predicted, and explained, the changes in microemulsion properties along dilution lines. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Honey dilution impact on in vitro wound healing: Normoxic and hypoxic condition.

    PubMed

    Chaudhary, Amrita; Bag, Swarnendu; Barui, Ananya; Banerjee, Provas; Chatterjee, Jyotirmoy

    2015-01-01

    Honey is known as a popular healing agent against tropical infections and wounds. However, the effects of honey dilutions on keratinocyte (HaCaT) wound healing under hypoxic condition is still not explored. In this study, we examined whether honey dilution have wound healing potential under hypoxic stress. The antioxidant potential and healing efficacy of honey dilution on in vitro wound of human epidermal keratinocyte (HaCaT cells) under hypoxia (3% O2 ), and normoxia is explored by nitro blue tetrazolium assay. The cell survival % quantified by MTT assay to select four honey dilutions like 10, 1, 0.1, and 0.01 v/v% and the changes in cellular function was observed microscopically. Further, the cell proliferation, migration, cell-cell adhesion, and relevant gene expression were studied by flow cytometry, migration/scratch assay, immunocytochemistry, and reverse transcription-polymerase chain reaction, respectively. The expression pattern of cardinal molecular features viz. E-cadherin, cytoskeletal protein F-actin, p63, and hypoxia marker Hif 1α were examined. Honey dilution in 0.1% v/v combat wound healing limitations in vitro under normoxia and hypoxia (3%). Its wound healing potential was quantified by immunocytochemistry and real-time PCR for the associated molecular features that were responsible for cell proliferation and migration. Our data showed that honey dilution can be effective in hypoxic wound healing. Additionally, it reduced superoxide generation and supplied favorable bioambience for cell proliferation, migration, and differentiation during hypoxic wound healing. These findings may reveal the importance of honey as an alternative and cost effective therapeutic natural product for wound healing in hypoxic condition. © 2015 by the Wound Healing Society.

  20. A fast ultrasound-assisted extraction procedure for trace elements determination in hair samples by ICP-MS for forensic analysis.

    PubMed

    Batista, Bruno Lemos; Rodrigues, Jairo Lisboa; Souza, Vanessa Cristina de Oliveira; Barbosa, Fernando

    2009-11-20

    An ultrasound-assisted extraction method is proposed for the determination of trace elements in hair samples by inductively coupled plasma-mass spectrometry (ICP-MS) for forensic investigation. Prior to analysis, 25mg of hair samples were accurately weighed into (15 mL) conical tubes. Then, 2 mL of 20% HNO(3) is added to the samples, sonicated at 2 min (50W, 100% amplitude), and then further diluted to 10 mL with Milli-Q water. Resulted diluted slurries are centrifuged and the analytes are directly determined in the supernatant. Calibrations against aqueous solutions were carried out with rhodium as internal standard. The method was successfully applied for the extraction of Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Pb, Tl, U, V and Zn with a method detection limit (3s, n=20) of 0.1, 0.4, 0.2, 0.09, 0.08, 0.04, 0.1, 2.9, 1.0, 0.9, 0.04, 0.05, 0.1 and 4.2 ng/g, respectively. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Additional validation data are provided based on the analysis of hair samples from the trace elements intercomparison program operated by the Institut National de Sante' Publique du Quebec, Canada. The proposed method is very simple and can be applied for forensic purposes with the elimination of sample digestion step prior to analysis. Then, a considerable improvement in the sample throughput is archived with the use of the proposed method.

  1. Characterization of the key aroma compounds in pork soup stock by using an aroma extract dilution analysis.

    PubMed

    Takakura, Yukiko; Osanai, Hiroki; Masuzawa, Takuya; Wakabayashi, Hidehiko; Nishimura, Toshihide

    2014-01-01

    The aroma extract dilution analysis of an extract prepared from pork stock and subsequent experiments led to the identification of 15 aroma-active compounds in the flavor dilution factor range of 64-2048. Omission experiments to select the most aroma-active compounds from the 15 odor compounds suggested acetol, octanoic acid, δ-decalactone, and decanoic acid as the main active compounds contributing to the aroma of pork stock. Aroma recombination, addition, and omission experiments of these four aroma compounds in taste-reconstituted pork stock showed that each compound had an individual aroma profile. A comparison of the overall aroma between this recombined mixture and pork stock showed strong similarity, suggesting that the key aroma compounds had been successfully identified.

  2. Characterization of the key aroma compounds in dried fruits of the West African peppertree Xylopia aethiopica (Dunal) A. Rich (Annonaceae) using aroma extract dilution analysis.

    PubMed

    Tairu, A O; Hofmann, T; Schieberle, P

    1999-08-01

    Application of aroma extract dilution analysis on an extract of the dried fruits of the West African peppertree Xylopia aethiopica obtained by extraction with diethyl ether followed by sublimation in vacuo revealed 28 odor-active compounds in the flavor dilution (FD) factor range of 4-8192, all of which could be identified. The highest FD factor was found for linalol (floral), followed by (E)-beta-ocimene (flowery), alpha-farnesene (sweet, flowery), beta-pinene (terpeny), alpha-pinene (pine needle-like), myrtenol (flowery), and beta-phellandrene (terpeny). Vanillin (vanilla-like) and 3-ethylphenol (smoky, phenolic) showing somewhat lower FD factors (FD = 128) were detected for the first time as constituents of the dried fruit.

  3. High mass accuracy assay for trimethylamine N-oxide using stable-isotope dilution with liquid chromatography coupled to orthogonal acceleration time of flight mass spectrometry with multiple reaction monitoring.

    PubMed

    Heaney, Liam M; Jones, Donald J L; Mbasu, Richard J; Ng, Leong L; Suzuki, Toru

    2016-01-01

    Trimethylamine N-oxide (TMAO) has attracted interest as circulating levels have reported prognostic value in patients with cardiovascular conditions, such as heart failure. With continual advances in accurate mass measurements, robust methods that can employ the capabilities of time of flight mass spectrometers would offer additional utility in the analysis of complex clinical samples. A Waters Acquity UPLC was coupled to a Waters Synapt G2-S high-resolution mass spectrometer. TMAO was measured in plasma by stable-isotope dilution-hydrophilic interaction liquid chromatography-time of flight mass spectrometry with multiple reaction monitoring (LC-ToF-MRM). Two transitions were monitored: m/z 76.1 to 58.066/59.073 and m/z 85.1 to 66.116/68.130. The method was assessed for linearity, lower limits of detection and quantitation, and reproducibility. A selected cohort of patients with systolic heart failure (SHF; n = 43) and healthy controls (n = 42) were measured to verify the assay is suitable for the analysis of clinical samples. Quantitative analysis of TMAO using LC-ToF-MRM enabled linearity to be established between 0.1 and 75 μmol/L, with a lower limit of detection of 0.05 μmol/L. Relative standard deviations reported an inter-day variation of ≤20.8% and an intra-day variation of ≤11.4% with an intra-study quality control variation of 2.7%. Run times were 2.5 min. Clinical application of the method reported that TMAO in SHF was elevated compared to that of healthy controls (p < 0.0005). LC-ToF-MRM offers a highly selective method for accurate mass measurement of TMAO with rapid and reproducible results. Applicability of the method was shown in a selected cohort of patient samples.

  4. A mass-balance code for the quantitative interpretation of fluid column profiles in ground-water studies

    NASA Astrophysics Data System (ADS)

    Paillet, Frederick

    2012-08-01

    A simple mass-balance code allows effective modeling of conventional fluid column resistivity logs in dilution tests involving column replacement with either distilled water or dilute brine. Modeling a series of column profiles where the inflowing formation water introduces water quality interfaces propagating along the borehole gives effective estimates of the rate of borehole flow. Application of the dilution model yields estimates of borehole flow rates that agree with measurements made with the heat-pulse flowmeter under ambient and pumping conditions. Model dilution experiments are used to demonstrate how dilution logging can extend the range of borehole flow measurement at least an order of magnitude beyond that achieved with flowmeters. However, dilution logging has the same dynamic range limitation encountered with flowmeters because it is difficult to detect and characterize flow zones that contribute a small fraction of total flow when that contribution is superimposed on a larger flow. When the smaller contribution is located below the primary zone, ambient downflow may disguise the zone if pumping is not strong enough to reverse the outflow. This situation can be addressed by increased pumping. But this is likely to make the moveout of water quality interfaces too fast to measure in the upper part of the borehole, so that a combination of flowmeter and dilution method may be more appropriate. Numerical experiments show that the expected weak horizontal flow across the borehole at conductive zones would be almost impossible to recognize if any ambient vertical flow is present. In situations where natural water quality differences occur such as flowing boreholes or injection experiments, the simple mass-balance code can be used to quantitatively model the evolution of fluid column logs. Otherwise, dilution experiments can be combined with high-resolution flowmeter profiles to obtain results not attainable using either method alone.

  5. L-edge sum rule analysis on 3d transition metal sites: from d10 to d0 and towards application to extremely dilute metallo-enzymes.

    PubMed

    Wang, Hongxin; Friedrich, Stephan; Li, Lei; Mao, Ziliang; Ge, Pinghua; Balasubramanian, Mahalingam; Patil, Daulat S

    2018-03-28

    According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0 . In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noise ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d 0 to a closed shell 3d 10 ; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. This study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.

  6. Two-stage, dilute sulfuric acid hydrolysis of wood : an investigation of fundamentals

    Treesearch

    John F. Harris; Andrew J. Baker; Anthony H. Conner; Thomas W. Jeffries; James L. Minor; Roger C. Pettersen; Ralph W. Scott; Edward L Springer; Theodore H. Wegner; John I. Zerbe

    1985-01-01

    This paper presents a fundamental analysis of the processing steps in the production of methanol from southern red oak (Quercus falcata Michx.) by two-stage dilute sulfuric acid hydrolysis. Data for hemicellulose and cellulose hydrolysis are correlated using models. This information is used to develop and evaluate a process design.

  7. STATISTICAL ESTIMATES OF VARIANCE FOR 15N ISOTOPE DILUTION MEASUREMENTS OF GROSS RATES OF NITROGEN CYCLE PROCESSES

    EPA Science Inventory

    It has been fifty years since Kirkham and Bartholmew (1954) presented the conceptual framework and derived the mathematical equations that formed the basis of the now commonly employed method of 15N isotope dilution. Although many advances in methodology and analysis have been ma...

  8. Orthorhombic-tetragonal phase coexistence and enhanced piezo-response at room temperature in Zr, Sn, and Hf modified BaTiO{sub 3}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalyani, Ajay Kumar; Brajesh, Kumar; Ranjan, Rajeev, E-mail: rajeev@materials.iisc.ernet.in

    2014-06-23

    The effect of Zr, Hf, and Sn in BaTiO{sub 3} has been investigated at close composition intervals in the dilute concentration limit. Detailed structural analysis by x-ray and neutron powder diffraction revealed that merely 2 mol. % of Zr, Sn, and Hf stabilizes a coexistence of orthorhombic (Amm2) and tetragonal (P4mm) phases at room temperature. As a consequence, all the three systems show substantial enhancement in the longitudinal piezoelectric coefficient (d{sub 33}), with Sn modification exhibiting the highest value ∼425 pC/N.

  9. Spectrophotometric Quantification of Flavonoids in Herbal Material, Crude Extract, and Fractions from Leaves of Eugenia uniflora Linn.

    PubMed

    Ramos, Rhayanne T M; Bezerra, Isabelle C F; Ferreira, Magda R A; Soares, Luiz Alberto Lira

    2017-01-01

    The traditional use of Eugenia uniflora L. ("Pitanga") is reported due to several properties, which have often been related to its flavonoid content. The aim was to evaluate analytical procedures for quantification of total flavonoids content (TFCs) by ultraviolet-visible (UV-Vis) spectrophotometry in the herbal material (HM), crude extract (CE), and fractions from leaves of E. uniflora . The method for quantification of flavonoids after complexation with aluminum chloride (AlCl 3 ) was evaluated: amount of sample (0.25-1.5 g); solvent (40%-80% ethanol); reaction time and AlCl 3 concentration (2.5%-7.5%). The procedures by direct dilution (DD) and after acid hydrolysis (AH) were used and validated for HM and CE and applied to the aqueous fraction (AqF), hexane fraction, and ethyl acetate fractions (EAF). The ideal conditions of analysis were ethanol 80% as solvent; 0.5 g of sample; λmax of 408 (DD) and 425 nm (AH); 25 min after addition of AlCl 3 5%. The procedures validated for standards and samples showed linearity ( R 2 > 0.99) with limit of detection and limit of quantification between 0.01 and 0.17 mg/mL (rutin and quercetin); and 0.03 and 0.09 mg/mL (quercetin), for DD and AH, respectively. The procedures were accurate (detect, practice, and repair < 5% and recovery >90%), and stable under robustness conditions (luminosity, storage, reagents, and equipment). The TFCs in AqF and EAF were 0.65 g% and 17.72 g%, calculated as rutin. UV-Vis methods for quantification of TFC in HM, CE, and fractions from leaves of E. uniflora were suitably validated. Regarding the analysis of fractions, the EAF achieved enrichment of about nine times in the content of flavonoids. The total flavonoids content (TFCs) of herbal material, crude extract, and fractions from Eugenia uniflora can be quantified by ultraviolet-visibleThe spectrophotometric methods (direct dilution and acid hydrolysis) were reproducible and able to quantify TFC in raw material and derivatives from leaves of E. uniflora Higher flavonoids content was observed in ethyl acetate fractions after enrichment. Abbreviations Used : HM: Herbal material, CE: Crude extract, AqF: Aqueous fraction, HF: Hexanic fraction, EAF: Ethyl acetate fraction, TFC: Total flavonoids content, HCl: Hydrochloric acid, DD: Direct dilution, AH: After hydrolysis, RSD: Relative standard, A.U.: Absorption units.

  10. Single point dilution method for the quantitative analysis of antibodies to the gag24 protein of HIV-1.

    PubMed

    Palenzuela, D O; Benítez, J; Rivero, J; Serrano, R; Ganzó, O

    1997-10-13

    In the present work a concept proposed in 1992 by Dopotka and Giesendorf was applied to the quantitative analysis of antibodies to the p24 protein of HIV-1 in infected asymptomatic individuals and AIDS patients. Two approaches were analyzed, a linear model OD = b0 + b1.log(titer) and a nonlinear log(titer) = alpha.OD beta, similar to the Dopotka-Giesendorf's model. The above two proposed models adequately fit the dependence of the optical density values at a single point dilution, and titers achieved by the end point dilution method (EPDM). Nevertheless, the nonlinear model better fits the experimental data, according to residuals analysis. Classical EPDM was compared with the new single point dilution method (SPDM) using both models. The best correlation between titers calculated using both models and titers achieved by EPDM was obtained with the nonlinear model. The correlation coefficients for the nonlinear and linear models were r = 0.85 and r = 0.77, respectively. A new correction factor was introduced into the nonlinear model and this reduced the day-to-day variation of titer values. In general, SPDM saves time, reagents and is more precise and sensitive to changes in antibody levels, and therefore has a higher resolution than EPDM.

  11. Profound effects of cardiopulmonary bypass priming solutions on the fibrin part of clot formation: an ex vivo evaluation using rotation thromboelastometry.

    PubMed

    Brinkman, Arinda C M; Romijn, Johannes W A; van Barneveld, Lerau J M; Greuters, Sjoerd; Veerhoek, Dennis; Vonk, Alexander B A; Boer, Christa

    2010-06-01

    Dilutional coagulopathy as a consequence of cardiopulmonary bypass (CPB) system priming may also be affected by the composition of the priming solution. The direct effects of distinct priming solutions on fibrinogen, one of the foremost limiting factors during dilutional coagulopathy, have been minimally evaluated. Therefore, the authors investigated whether hemodilution with different priming solutions distinctly affects the fibrinogen-mediated step in whole blood clot formation. Prospective observational laboratory study. University hospital laboratory. Eight male healthy volunteers. Blood samples diluted with gelatin-, albumin-, or hydroxyethyl starch (HES)-based priming solutions were ex-vivo evaluated for clot formation by rotational thromboelastometry. The intrinsic pathway (INTEM) coagulation time increased from 186 +/- 19 seconds to 205 +/- 16, 220 +/- 17, and 223 +/- 18 seconds after dilution with gelatin-, albumin-, or HES-containing prime solutions (all p < 0.05 v baseline). The extrinsic pathway (EXTEM) coagulation time was only minimally affected by hemodilution. Moreover, all 3 priming solutions significantly reduced the INTEM and EXTEM maximum clot firmness. The HES-containing priming solution induced the largest decrease in the maximum clot firmness attributed to fibrinogen, from 13 +/- 1 mm (baseline) to 6 +/- 1 mm (p < 0.01 v baseline). All studied priming solutions prolonged coagulation time and decreased clot formation, but the fibrinogen-limiting effect was the most profound for the HES-containing priming solution. These results suggest that the composition of priming solutions may distinctly affect blood clot formation, in particular with respect to the fibrinogen component in hemostasis. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Heat transfer optimization for air-mist cooling between a stack of parallel plates

    NASA Astrophysics Data System (ADS)

    Issa, Roy J.

    2010-06-01

    A theoretical model is developed to predict the upper limit heat transfer between a stack of parallel plates subject to multiphase cooling by air-mist flow. The model predicts the optimal separation distance between the plates based on the development of the boundary layers for small and large separation distances, and for dilute mist conditions. Simulation results show the optimal separation distance to be strongly dependent on the liquid-to-air mass flow rate loading ratio, and reach a limit for a critical loading. For these dilute spray conditions, complete evaporation of the droplets takes place. Simulation results also show the optimal separation distance decreases with the increase in the mist flow rate. The proposed theoretical model shall lead to a better understanding of the design of fins spacing in heat exchangers where multiphase spray cooling is used.

  13. A dilute-and-shoot sample preparation strategy for new and used lubricating oils for Ca, P, S and Zn determination by total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Mota, Mariana F. B.; Gama, Ednilton M.; Rodrigues, Gabrielle de C.; Rodrigues, Guilherme D.; Nascentes, Clésia C.; Costa, Letícia M.

    2018-01-01

    In this work, a dilute-and-shoot method was developed for Ca, P, S and Zn determination in new and used lubricating oil samples by total reflection X-ray fluorescence (TXRF). The oil samples were diluted with organic solvents followed by addition of yttrium as internal standard and the TXRF measurements were performed after solvent evaporation. The method was optimized using an interlaboratorial reference material. The experimental parameters evaluated were sample volume (50 or 100 μL), measurement time (250 or 500 s) and volume deposited on the quartz glass sample carrier (5 or 10 μL). All of them were evaluated and optimized using xylene, kerosene and hexane. Analytical figures of merit (accuracy, precision, limit of detection and quantification) were used to evaluate the performance of the analytical method for all solvents. The recovery rates varied from 99 to 111% and the relative standard deviation remained between 1.7% and 10% (n = 8). For all elements, the results obtained by applying the new method were in agreement with the certified value. After the validation step, the method was applied for Ca, P, S and Zn quantification in eight new and four used lubricating oil samples, for all solvents. The concentration of the elements in the samples varied in the ranges of 1620-3711 mg L- 1 for Ca, 704-1277 mg L- 1 for P, 2027-9147 mg L- 1 for S, and 898-1593 mg L- 1 for Zn. The association of TXRF with a dilute-and-shoot sample preparation strategy was efficient for Ca, P, S and Zn determination in lubricating oils, presenting accurate results. Additionally, the time required for analysis is short, the reagent volumes are low minimizing waste generation, and the technique does not require calibration curves.

  14. Polymorphisms within the canine MLPH gene are associated with dilute coat color in dogs

    PubMed Central

    Philipp, Ute; Hamann, Henning; Mecklenburg, Lars; Nishino, Seiji; Mignot, Emmanuel; Günzel-Apel, Anne-Rose; Schmutz, Sheila M; Leeb, Tosso

    2005-01-01

    Background Pinschers and other dogs with coat color dilution show a characteristic pigmentation phenotype. The fur colors are a lighter shade, e.g. silvery grey (blue) instead of black and a sandy color (Isabella fawn) instead of red or brown. In some dogs the coat color dilution is sometimes accompanied by hair loss and recurrent skin inflammation, the so called color dilution alopecia (CDA) or black hair follicular dysplasia (BHFD). In humans and mice a comparable pigmentation phenotype without any documented hair loss is caused by mutations within the melanophilin gene (MLPH). Results We sequenced the canine MLPH gene and performed a mutation analysis of the MLPH exons in 6 Doberman Pinschers and 5 German Pinschers. A total of 48 sequence variations was identified within and between the breeds. Three families of dogs showed co-segregation for at least one polymorphism in an MLPH exon and the dilute phenotype. No single polymorphism was identified in the coding sequences or at splice sites that is likely to be causative for the dilute phenotype of all dogs examined. In 18 German Pinschers a mutation in exon 7 (R199H) was consistently associated with the dilute phenotype. However, as this mutation was present in homozygous state in four dogs of other breeds with wildtype pigmentation, it seems unlikely that this mutation is truly causative for coat color dilution. In Doberman Pinschers as well as in Large Munsterlanders with BHFD, a set of single nucleotide polymorphisms (SNPs) around exon 2 was identified that show a highly significant association to the dilute phenotype. Conclusion This study provides evidence that coat color dilution is caused by one or more mutations within or near the MLPH gene in several dog breeds. The data on polymorphisms that are strongly associated with the dilute phenotype will allow the genetic testing of Pinschers to facilitate the breeding of dogs with defined coat colors and to select against Large Munsterlanders carrying BHFD. PMID:15960853

  15. Polymorphisms within the canine MLPH gene are associated with dilute coat color in dogs.

    PubMed

    Philipp, Ute; Hamann, Henning; Mecklenburg, Lars; Nishino, Seiji; Mignot, Emmanuel; Günzel-Apel, Anne-Rose; Schmutz, Sheila M; Leeb, Tosso

    2005-06-16

    Pinschers and other dogs with coat color dilution show a characteristic pigmentation phenotype. The fur colors are a lighter shade, e.g. silvery grey (blue) instead of black and a sandy color (Isabella fawn) instead of red or brown. In some dogs the coat color dilution is sometimes accompanied by hair loss and recurrent skin inflammation, the so called color dilution alopecia (CDA) or black hair follicular dysplasia (BHFD). In humans and mice a comparable pigmentation phenotype without any documented hair loss is caused by mutations within the melanophilin gene (MLPH). We sequenced the canine MLPH gene and performed a mutation analysis of the MLPH exons in 6 Doberman Pinschers and 5 German Pinschers. A total of 48 sequence variations was identified within and between the breeds. Three families of dogs showed co-segregation for at least one polymorphism in an MLPH exon and the dilute phenotype. No single polymorphism was identified in the coding sequences or at splice sites that is likely to be causative for the dilute phenotype of all dogs examined. In 18 German Pinschers a mutation in exon 7 (R199H) was consistently associated with the dilute phenotype. However, as this mutation was present in homozygous state in four dogs of other breeds with wildtype pigmentation, it seems unlikely that this mutation is truly causative for coat color dilution. In Doberman Pinschers as well as in Large Munsterlanders with BHFD, a set of single nucleotide polymorphisms (SNPs) around exon 2 was identified that show a highly significant association to the dilute phenotype. This study provides evidence that coat color dilution is caused by one or more mutations within or near the MLPH gene in several dog breeds. The data on polymorphisms that are strongly associated with the dilute phenotype will allow the genetic testing of Pinschers to facilitate the breeding of dogs with defined coat colors and to select against Large Munsterlanders carrying BHFD.

  16. Automated fluid analysis apparatus and techniques

    DOEpatents

    Szecsody, James E.

    2004-03-16

    An automated device that couples a pair of differently sized sample loops with a syringe pump and a source of degassed water. A fluid sample is mounted at an inlet port and delivered to the sample loops. A selected sample from the sample loops is diluted in the syringe pump with the degassed water and fed to a flow through detector for analysis. The sample inlet is also directly connected to the syringe pump to selectively perform analysis without dilution. The device is airtight and used to detect oxygen-sensitive species, such as dithionite in groundwater following a remedial injection to treat soil contamination.

  17. Potts-model formulation of the random resistor network

    NASA Astrophysics Data System (ADS)

    Harris, A. B.; Lubensky, T. C.

    1987-05-01

    The randomly diluted resistor network is formulated in terms of an n-replicated s-state Potts model with a spin-spin coupling constant J in the limit when first n, then s, and finally 1/J go to zero. This limit is discussed and to leading order in 1/J the generalized susceptibility is shown to reproduce the results of the accompanying paper where the resistor network is treated using the xy model. This Potts Hamiltonian is converted into a field theory by the usual Hubbard-Stratonovich transformation and thereby a renormalization-group treatment is developed to obtain the corrections to the critical exponents to first order in ɛ=6-d, where d is the spatial dimensionality. The recursion relations are shown to be the same as for the xy model. Their detailed analysis (given in the accompanying paper) gives the resistance crossover exponent as φ1=1+ɛ/42, and determines the critical exponent, t for the conductivity of the randomly diluted resistor network at concentrations, p, just above the percolation threshold: t=(d-2)ν+φ1, where ν is the critical exponent for the correlation length at the percolation threshold. These results correct previously accepted results giving φ=1 to all orders in ɛ. The new result for φ1 removes the paradox associated with the numerical result that t>1 for d=2, and also shows that the Alexander-Orbach conjecture, while numerically quite accurate, is not exact, since it disagrees with the ɛ expansion.

  18. Faecal pollution along the southeastern coast of Florida and insight into the use of pepper mild mottle virus as an indicator.

    PubMed

    Symonds, E M; Sinigalliano, C; Gidley, M; Ahmed, W; McQuaig-Ulrich, S M; Breitbart, M

    2016-11-01

    To identify faecal pollution along the southeastern Florida coast and determine the performance of a reverse transcription-quantitative polymerase chain reaction (RT-qPCR) method for pepper mild mottle virus (PMMoV). In 2014, bimonthly surface water samples were collected from inlets, exposed to runoff and septic seepage, and coastal sites, exposed to ocean outfalls. Analysis of culturable enterococci and a suite of microbial source tracking (MST) markers (BacHum, CowM2, DogBact, HF183, HPyV, PMMoV) revealed faecal pollution, primarily of human origin, at all sites. Since PMMoV was detected more frequently than other MST markers, the process limits of quantification (undiluted to 10 -2 dilution) and detection (10 -2 dilution) for the RT-qPCR method were determined by seeding untreated wastewater into the coastal waters. Simulated quantitative microbial risk assessment, employing human norovirus as a reference pathogen, calculated a 0·286 median risk of gastrointestinal illness associated with the PMMoV limit of detection. All sites met the U.S. EPA recreational water criteria, despite detection of domestic wastewater-associated MST markers. PMMoV correlated only with human-associated MST markers. This study demonstrated that PMMoV is an important domestic wastewater-associated marker that should be included in the MST toolbox; therefore, future studies should thoroughly investigate the health risks associated with its detection and quantification in environmental waters. © 2016 The Society for Applied Microbiology.

  19. Sensitive analysis of steroid estrogens and bisphenol a in small volumes of water using isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chang, Hong; Shen, Xiaoyan; Shao, Bing; Wu, Fengchang

    2018-04-01

    An isotope-dilution ultra-performance liquid chromatography-electrospray tandem mass spectrometry method combined with dansylation was established to sensitively quantify four steroid estrogens (estrone, 17α-estradiol, 17β-estradiol and 17α-ethynylestradiol) and bisphenol A in sewage influent and effluent. A simple hexane extraction was performed from a small volume (10 mL), followed by dansyl chloride derivatization and purification with a silica cartridge. The method effectively reduced the matrix effects in sample extract and permitted the selective and sensitive determination of target compounds from complicated matrices. The detection limits of the method for steroid estrogens were 0.20-0.90 ng L -1 in influent and 0.10-0.20 ng L -1 in effluent samples. For bisphenol A, the limits detection of the method were 20 and 0.80 for influent and effluent samples, respectively. Recoveries of 85%-96% were observed in all matrices. The method was applied to analyze residual estrogens and bisphenol A in sewage influent and effluent samples from Beijing, China. The concentrations of bisphenol A (636-1200 ng L -1 ) were up to 250 times higher than those of steroid estrogens. Estrone was the dominant estrogen in influent and effluent samples, while similar concentrations of 17α-estradiol and 17β-estradiol were detected in all samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Fast analysis of quaternary ammonium pesticides in food and beverages using cation-exchange chromatography coupled with isotope-dilution high-resolution mass spectrometry.

    PubMed

    Nardin, Tiziana; Barnaba, Chiara; Abballe, Franco; Trenti, Gianmaria; Malacarne, Mario; Larcher, Roberto

    2017-10-01

    A fast separation based on cation-exchange liquid chromatography coupled with high-resolution mass spectrometry is proposed for simultaneous determination of chlormequat, difenzoquat, diquat, mepiquat and paraquat in several food and beverage commodities. Solid samples were extracted using a mixture of water/methanol/formic acid (69.6:30:0.4, v/v/v), while liquid samples were ten times diluted with the same solution. Separation was carried out on an experimental length-modified IonPac CS17 column (2 × 15 mm 2 ) that allowed the use of formic acid and acetonitrile as mobile phase. Detection limits for food and beverage matrices were established at 1.5 μg/L for chlormequat, difenzoquat and mepiquat, and 3 μg/L for diquat and paraquat, while for drinking water a pre-analytical sample concentration allowed detection limits of 9 and 20 ng/L, respectively. Precision, as repeatability (RSD%), ranged from 0.2 to 24%, with a median value of 6%, and trueness, as recovery, ranged from 64 to 118%, with a median value of 96%. The method developed was successfully applied to investigate the presence of herbicide residues in commercial commodities (mineral water, orange juice, beer, tea, green coffee bean, toasted coffee powder, cocoa bean, white corn flour, rice and sugar samples). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Acetate scavenging activity in Escherichia coli: interplay of acetyl-CoA synthetase and the PEP-glyoxylate cycle in chemostat cultures.

    PubMed

    Renilla, Sergio; Bernal, Vicente; Fuhrer, Tobias; Castaño-Cerezo, Sara; Pastor, José M; Iborra, José L; Sauer, Uwe; Cánovas, Manuel

    2012-03-01

    Impairment of acetate production in Escherichia coli is crucial for the performance of many biotechnological processes. Aerobic production of acetate (or acetate overflow) results from changes in the expression of central metabolism genes. Acetyl-CoA synthetase scavenges extracellular acetate in glucose-limited cultures. Once converted to acetyl-CoA, it can be catabolized by the tricarboxylic acid cycle or the glyoxylate pathway. In this work, we assessed the significance of these pathways on acetate overflow during glucose excess and limitation. Gene expression, enzyme activities, and metabolic fluxes were studied in E. coli knock-out mutants related to the glyoxylate pathway operon and its regulators. The relevance of post-translational regulation by AceK-mediated phosphorylation of isocitrate dehydrogenase for pathway functionality was underlined. In chemostat cultures performed at increasing dilution rates, acetate overflow occurs when growing over a threshold glucose uptake rate. This threshold was not affected in a glyoxylate-pathway-deficient strain (lacking isocitrate lyase, the first enzyme of the pathway), indicating that it is not relevant for acetate overflow. In carbon-limited chemostat cultures, gluconeogenesis (maeB, sfcA, and pck), the glyoxylate operon and, especially, acetyl-CoA synthetase are upregulated. A mutant in acs (encoding acetyl-CoA synthetase) produced acetate at all dilution rates. This work demonstrates that, in E. coli, acetate production occurs at all dilution rates and that overflow is the result of unbalanced synthesis and scavenging activities. The over-expression of acetyl-CoA synthetase by cAMP-CRP-dependent induction limits this phenomenon in cultures consuming glucose at low rate, ensuring the recycling of the acetyl-CoA and acetyl-phosphate pools, although establishing an energy-dissipating substrate cycle.

  2. Body fat of stock-type horses predicted by rump fat thickness and deuterium oxide dilution and validated by near-infrared spectroscopy of dissected tissues.

    PubMed

    Ferjak, E N; Cavinder, C A; Burnett, D D; Argo, C Mc; Dinh, T T N

    2017-10-01

    Body condition score and percent body fat (BF; %) of horses are positively correlated with reproductive efficiency and are indicative of metabolic issues. However, BF in horses may be poorly predicted because current procedures are either subjective or dependent on one anatomical location. Therefore, the objectives of the current study were to compare 2 methods of predicting BF using rump fat thickness (RFT) and deuterium oxide (DO) dilution with actual tissue fat analysis by near-infrared spectroscopy (NIRS) in stock-type horses and to identify the relationship between BF and BCS. Twenty-four stock-type horses were selected to be humanely euthanized based on 3 primary criteria: geriatric, crippled, and/or unsafe. Approximately 20 h before slaughter, horses were weighed and BCS assessed to be 1 ( = 1; 433 kg), 2 ( = 1; 415 kg), 3 ( = 1; 376 kg), 4 ( = 7; 468 ± 13 kg), 5 ( = 10; 455 ± 11 kg), and 6 ( = 4; 493 ± 12 kg) and RFT was measured using ultrasonography. Blood samples were collected immediately before and 4 h after DO infusion (0.12 g/kg BW). Deuterium oxide concentration of plasma was determined by gas isotope ratio mass spectrometry. Horses were housed in a dry lot overnight before being individually sedated (1.1 mg xylazine/kg BW) and anesthetized using a jugular venipuncture (2.2 mg ketamine/kg BW), and potassium chloride (KCl) solution was administered to cease cardiac function before exsanguination. After euthanasia, horse carcasses were processed and dissected and tissues were collected for NIRS analysis. Body fat predicted by DO dilution was correlated with BF measured by NIRS analysis on various weight bases ( = 0.76 to 0.81, < 0.001), whereas no correlation was observed for BF predicted by RFT. A paired -test indicated that both DO dilution and RFT overestimated BF by 2.48 to 3.26% ( < 0.001) and 5.81 to 6.59% ( < 0.001), respectively, compared with NIRS analysis. Body condition scores affected BF measured by NIRS analysis ( ≤ 0.038) and predicted by DO dilution ( < 0.001) and RFT ( = 0.042). The current study provided evidence that DO dilution was a better prediction method for BF than RFT and that BCS may serve as a BF predictor in stock-type horses.

  3. Quality- and dilution losses in the recycling of ferrous materials from end-of-life passenger cars: input-output analysis under explicit consideration of scrap quality.

    PubMed

    Nakamura, Shinichiro; Kondo, Yasushi; Matsubae, Kazuyo; Nakajima, Kenichi; Tasaki, Tomohiro; Nagasaka, Tetsuya

    2012-09-04

    Metals can in theory be infinitely recycled in a closed-loop without any degradation in quality. In reality, however, open-loop recycling is more typical for metal scrap recovered from end-of-life (EoL) products because mixing of different metal species results in scrap quality that no longer matches the originals. Further losses occur when meeting the quality requirement of the target product requires dilution of the secondary material by adding high purity materials. Standard LCA usually does not address these losses. This paper presents a novel approach to quantifying quality- and dilution losses, by means of hybrid input-output analysis. We focus on the losses associated with the recycling of ferrous materials from end-of-life vehicle (ELV) due to the mixing of copper, a typical contaminant in steel recycling. Given the quality of scrap in terms of copper density, the model determines the ratio by which scrap needs to be diluted in an electric arc furnace (EAF), and the amount of demand for EAF steel including those quantities needed for dilution. Application to a high-resolution Japanese IO table supplemented with data on ferrous materials including different grades of scrap indicates that a nationwide avoidance of these losses could result in a significant reduction of CO(2) emissions.

  4. Animal models for studying homeopathy and high dilutions: conceptual critical review.

    PubMed

    Bonamin, Leoni Villano; Endler, Peter Christian

    2010-01-01

    This is a systematic review of the animal models used in studies of high dilutions. The objectives are to analyze methodological quality of papers and reported results, and to highlight key conceptual aspects of high dilution to suggest clues concerning putative mechanisms of action. Papers for inclusion were identified systematically, from the Pubmed-Medline database, using 'Homeopathy' and 'Animal' as keywords. Only original full papers in English published between January 1999 and June 2009 were included, reviews, scientific reports, thesis, older papers, papers extracted from Medline using similar keywords, papers about mixed commercial formulas and books were also considered for discussion only. 31 papers describing 33 experiments were identified for the main analysis and a total of 89 items cited. Systematic analysis of the selected papers yielded evidence of some important intrinsic features of high dilution studies performed in animal models: a) methodological quality was generally adequate, some aspects could be improved; b) convergence between results and materia medica is seen in some studies, pointing toward to the possibility of systematic study of the Similia principle c) both isopathic and Similia models seem useful to understand some complex biological phenomena, such as parasite-host interactions; d) the effects of high dilutions seem to stimulate restoration of a 'stable state', as seen in several experimental models from both descriptive and mathematical points of view. Copyright 2009 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  5. Optimization and analysis of NF3 in situ chamber cleaning plasmas

    NASA Astrophysics Data System (ADS)

    Ji, Bing; Yang, James H.; Badowski, Peter R.; Karwacki, Eugene J.

    2004-04-01

    We report on the optimization and analysis of a dilute NF3 in situ plasma-enhanced chemical vapor deposition chamber cleaning plasma for an Applied Materials P-5000 DxL chamber. Using design of experiments methodology, we identified and optimized operating conditions within the following process space: 10-15 mol % NF3 diluted with helium, 200-400 sccm NF3 flow rate, 2.5-3.5 Torr chamber pressure, and 950 W rf power. Optical emission spectroscopy and Fourier transform infrared spectroscopy were used to endpoint the cleaning processes and to quantify plasma effluent emissions, respectively. The results demonstrate that dilute NF3-based in situ chamber cleaning can be a viable alternative to perfluorocarbon-based in situ cleans with added benefits. The relationship between chamber clean time and fluorine atom density in the plasma is also investigated.

  6. Automatic dilution gaging of rapidly varying flow

    USGS Publications Warehouse

    Duerk, M.D.

    1983-01-01

    The analysis showed that the discharges measured by dye-dilution techniques were generally within ± 10 percent of the discharges determined from ratings established by current-meter measurements. Larger differences were noted at the start of and on the rising limb of four hydrographs. Of the 20 storms monitored, dilution measurements on 17 were of acceptable accuracy. Peak discharges from the open-channel site ranged from 0 to 12 percent departures from the existing rating whereas the comparison of peak discharge at the storm sewer site ranged from 0 to 5 percent departures from the existing rating.

  7. Muon spin rotation research program

    NASA Technical Reports Server (NTRS)

    Stronach, C. E.

    1980-01-01

    Data from cyclotron experiments and room temperature studies of dilute iron alloys and iron crystals under strain were analyzed. The Fe(Mo) data indicate that the effect upon the contact hyperfine field in Fe due to the introduction of Mo is considerably less than that expected from pure dilution, and the muon (+) are attracted to the Mo impurity sites. There is a significant change in the interstitial magnetic field with Nb concentration. The Fe(Ti) data, for which precession could clearly be observed early only at 468K and above, show that the Ti impurities are attractive to muon (+), and the magnitude of B(hf) is reduced far beyond the amount expected from pure dilution. Changes in the intersitital magnetic field with the introduction of Cr, W, Ge, and Si are also discussed. When strained to the elastic limit, the interstitial magnetic field in Fe crystals is reduced by 33 gauss, and the relaxation rate of the precession signal increases by 47%.

  8. Continuous cultivation approach for fermentative succinic acid production from crude glycerol by Basfia succiniciproducens DD1.

    PubMed

    Scholten, Edzard; Renz, Torsten; Thomas, Jochen

    2009-12-01

    A continuous cultivation process for the fermentative production of succinic acid from glycerol with the recently isolated bacterium Basfia succiniciproducens DD1 was developed. Crude glycerol (5.1 g l(-1)) was used as C-source and NH(4)OH as N-source and pH-control agent. The problem of wall growth was solved by transfers of the cultivation broth into an empty identical fermentor. The resulting continuous cultivation process was maintained for more than 80 days. Glycerol-limited steady states were established for dilution rates between 0.004 and 0.018 h(-1). Higher dilution rates resulted in glycerol accumulation. Succinic acid concentrations, productivities, yields and specific productivities increased with increasing dilution rates: at 0.018 h(-1) the highest values were 5.21 g l(-1), 0.094 g l(-1) h(-1), 1.02 g g(-1) and 0.375 g g(-1) h(-1), respectively.

  9. Spectral radiance measurements and calculated soot concentrations along the length of an experimental combustor

    NASA Technical Reports Server (NTRS)

    Norgren, C. T.; Ingebo, R. D.

    1976-01-01

    Radiometric data were obtained over a range of parametric test conditions at three positions along the length of an experimental combustor segment corresponding to the primary, intermediate, and dilution zones. The concentration of soot entrained in the combustion gases was calculated by a technique using spectral radiance measurements. Tests were conducted primarily with Jet A fuel, although limited data were taken with two fuels having higher aromatic content, diesel oil number 2 and a blend of 40 percent tetralin in Jet A fuel. Radiometric observation of the combustion gases indicated that the maximum total radiance peaked at the intermediate zone, which was located immediately upstream of the dilution holes. Soot concentrations calculated from optical measurements in the dilution zone compared favorably with those obtained by in situ gas sampling at the exhaust. The total radiance increased with the higher aromatic content fuels.

  10. Forest species diversity reduces disease risk in a generalist plant pathogen invasion

    USGS Publications Warehouse

    Haas, Sarah E.; Hooten, Mevin B.; Rizzo, David M.; Meentemeyer, Ross K.

    2011-01-01

    Empirical evidence suggests that biodiversity loss can increase disease transmission, yet our understanding of the 'diversity-disease hypothesis' for generalist pathogens in natural ecosystems is limited. We used a landscape epidemiological approach to examine two scenarios regarding diversity effects on the emerging plant pathogen Phytophthora ramorum across a broad, heterogeneous ecoregion: (1) an amplification effect exists where disease risk is greater in areas with higher plant diversity due to the pathogen's wide host range, or (2) a dilution effect where risk is reduced with increasing diversity due to lower competency of alternative hosts. We found evidence for pathogen dilution, whereby disease risk was lower in sites with higher species diversity, after accounting for potentially confounding effects of host density and landscape heterogeneity. Our results suggest that although nearly all plants in the ecosystem are hosts, alternative hosts may dilute disease transmission by competent hosts, thereby buffering forest health from infectious disease.

  11. Quantifying the dilution effect for models in ecological epidemiology.

    PubMed

    Roberts, M G; Heesterbeek, J A P

    2018-03-01

    The dilution effect , where an increase in biodiversity results in a reduction in the prevalence of an infectious disease, has been the subject of speculation and controversy. Conversely, an amplification effect occurs when increased biodiversity is related to an increase in prevalence. We explore the conditions under which these effects arise, using multi species compartmental models that integrate ecological and epidemiological interactions. We introduce three potential metrics for quantifying dilution and amplification, one based on infection prevalence in a focal host species, one based on the size of the infected subpopulation of that species and one based on the basic reproduction number. We introduce our approach in the simplest epidemiological setting with two species, and show that the existence and strength of a dilution effect is influenced strongly by the choices made to describe the system and the metric used to gauge the effect. We show that our method can be generalized to any number of species and to more complicated ecological and epidemiological dynamics. Our method allows a rigorous analysis of ecological systems where dilution effects have been postulated, and contributes to future progress in understanding the phenomenon of dilution in the context of infectious disease dynamics and infection risk. © 2018 The Author(s).

  12. Evaluation of biocompatibility of sodium perborate and 30% hydrogen peroxide using the analysis of the adherence capacity and morphology of macrophages.

    PubMed

    Asfora, Kattyenne Kabbaz; Santos, Maria do Carmo Moreira da Silva; Montes, Marcos Antonio Japiassú Resende; de Castro, Célia Maria Machado Barbosa

    2005-02-01

    The purpose of this study was to evaluate the biocompatibility of the most used bleaching materials for pulpless teeth, sodium perborate and 30% hydrogen peroxide, in an experimental model of macrophages, through analysis of the adherence index and the cellular morphology. Inflammatory macrophages were obtained from peritoneal washed of Wistar rats. The evaluation of the adherence capacity of these cells to the plastic surface was conducted in Eppendorf tubes containing RPMI, after treatment with the bleaching agents diluted in 1:10, 1:100 and 1:1000 for 15 and 30 min, and incubation at 37 degrees C and humidified atmosphere of 5% CO(2) in air. The cellular morphology was verified after incubation of the cells treated with the bleaching agents in culture plaques and compared with normal cells in culture medium. Results showed that sodium perborate neither increased the adherence index, nor altered the cellular morphology when compared to the control group. The distribution, cellular morphology, cytoplasmatic and nuclear characteristics, reproduced the aspects observed in normal macrophages. However, the treatment with 30% hydrogen peroxide presented an increase in adherence index when compared to the control group (RPMI), in all dilutions, according to Mann-Whitney test (n=08 and p=0.001 for dilutions 1:10 and 1:100, and n=08 and p=0.004 for dilution 1:1000). The morphology of the cells treated with this product presented structural alterations proportionally greater, depending on the dilution of this bleaching agent, and even in the highest dilution (1:1000) the cells presented very evident alterations. This irreversible cellular damage as well as the elevation of the adherence index, characterizes the aggressive potential of 30% hydrogen peroxide, regardless of its dilution. Sodium perborate, on the other hand, showed biocompatibitity, since, no morphological nor functional alteration was observed in macrophages.

  13. Electrothermal atomic absorption spectrometric determination of arsenic in essential lavender and rose oils.

    PubMed

    Karadjova, Irina B; Lampugnani, Leonardo; Tsalev, Dimiter L

    2005-02-28

    Analytical procedures for electrothermal atomic absorption spectrometric (ETAAS) determination of arsenic in essential oils from lavender (Lavendula angustifolia) and rose (Rosa damascena) are described. For direct ETAAS analysis, oil samples are diluted with ethanol or i-propanol for lavender and rose oil, respectively. Leveling off responses of four different arsenic species (arsenite, arsenate, monomethylarsonate and dimethylarsinate) is achieved by using a composite chemical modifier: l-cysteine (0.05gl(-1)) in combination with palladium (2.5mug) and citric acid (100mug). Transverse-heated graphite atomizer (THGA) with longitudinal Zeeman-effect background correction and 'end-capped' graphite tubes with integrated pyrolytic graphite platforms, pre-treated with Zr-Ir for permanent modification are employed as most appropriate atomizer. Calibration with solvent-matched standard solutions of As(III) is used for four- and five-fold diluted samples of lavender and rose oil, respectively. Lower dilution factors required standard addition calibration by using aqueous (for lavender oil) or i-propanol (for rose oil) solutions of As(III). The limits of detection (LOD) for the whole analytical procedure are 4.4 and 4.7ngg(-1) As in levender and rose oil, respectively. The relative standard deviation (R.S.D.) for As at 6-30ngg(-1) levels is between 8 and 17% for both oils. As an alternative, procedure based on low temperature plasma ashing in oxygen with ETAAS, providing LODs of 2.5 and 2.7ngg(-1) As in levender and rose oil, respectively, and R.S.D. within 8-12% for both oils has been elaborated. Results obtained by both procedures are in good agreement.

  14. Measurement by ICP-MS of lead in plasma and whole blood of lead workers and controls.

    PubMed Central

    Schütz, A; Bergdahl, I A; Ekholm, A; Skerfving, S

    1996-01-01

    OBJECTIVES: To test a simple procedure for preparing samples for measurement of lead in blood plasma (P-Pb) and whole blood (B-Pb) by inductively coupled plasma mass spectrometry (ICP-MS), to measure P-Pb and B-Pb in lead workers and controls, and to evaluate any differences in the relation between B-Pb and P-Pb between people. METHODS: P-Pb and B-Pb were measured by ICP-MS in 43 male lead smelter workers and seven controls without occupational exposure to lead. For analysis, plasma and whole blood were diluted 1 in 4 and 1 in 9, respectively, with a diluted ammonia solution containing Triton-X 100 and EDTA. The samples were handled under routine laboratory conditions, without clean room facilities. RESULTS: P-Pb was measured with good precision (CV = 5%) even at concentrations present in the controls. Freeze storage of the samples had no effect on the results. The detection limit was 0.015 microgram/l. The P-Pb was 0.15 (range 0.1-0.3) microgram/l in controls and 1.2 (0.3-3.6) micrograms/l in lead workers, although the corresponding B-Pbs were 40 (24-59) micrograms/l and 281 (60-530) micrograms/l (1 microgram Pb/I = 4.8 nmol/l). B-Pb was closely associated with P-Pb (r = 0.90). The association was evidently non-linear; the ratio B-Pb/P-Pb decreased with increasing P-Pb. CONCLUSIONS: By means of ICP-MS and a simple dilution procedure, P-Pb may be measured accurately and with good precision down to concentrations present in controls. Contamination of blood at sampling and analysis is no major problem. With increasing P-Pb, the percentage of lead in plasma increases. In studies of lead toxicity, P-Pb should be considered as a complement to current indicators of lead exposure and risk. PMID:9038796

  15. Removal of Salmonella Enteritidis from commercial unpasteurized liquid egg white using pilot scale cross flow tangential microfiltration.

    PubMed

    Mukhopadhyay, Sudarsan; Tomasula, Peggy M; Luchansky, John B; Porto-Fett, Anna; Call, Jeffrey E

    2010-09-01

    Effectiveness of a cross flow microfiltration (MF) process for removal of a cocktail of Salmonella enterica serovar Enteritidis species from commercial unpasteurized liquid egg white (LEW) from a local egg breaking plant, while maintaining its functional properties was evaluated. To facilitate MF, LEW was wedge screened, homogenized and then diluted (1:2 w/w) with distilled water containing 0.5% sodium chloride. Diluted unpasteurized LEW was inoculated with five strains of S. Enteritidis (ATCC 4931, ATCC BAA-708, ATCC 49215, ATCC 49218, and ATCC BAA-1045) to a level of approximately 10(7)CFU/mL of LEW and microfiltered using a ceramic membrane. Process parameters influencing egg white functional properties and pathogen removal efficiency were evaluated. Average permeates flux increased by almost 126% when pH of LEW was adjusted from pH 8 to pH 7 at 25 degrees C. Microbial removal efficiency was at least, on average, 6.8Log(10)CFU/mL (limit of detection < or =0.5Log(10)CFU/mL). Functional property analysis indicated that the MF process did not alter the foaming power of LEW. Published by Elsevier B.V.

  16. Clustering and entrainment effects on the evaporation of dilute droplets in a turbulent jet

    NASA Astrophysics Data System (ADS)

    Dalla Barba, Federico; Picano, Francesco

    2018-03-01

    The evaporation of droplets within turbulent sprays involves unsteady, multiscale, and multiphase processes which make its comprehension and modeling capabilities still limited. The present work aims to investigate the dynamics of droplet vaporization within a turbulent spatial developing jet in dilute, nonreacting conditions. We address the problem considering a turbulent jet laden with acetone droplets and using the direct numerical simulation framework based on a hybrid Eulerian-Lagrangian approach and the point droplet approximation. A detailed statistical analysis of both phases is presented. In particular, we show how crucial is the preferential sampling of the vapor phase induced by the inhomogeneous localization of the droplets through the flow. Strong droplet preferential segregation develops suddenly downstream from the inflow section both within the turbulent core and the jet mixing layer. Two distinct mechanisms have been found to drive this phenomenon: the inertial small-scale clustering in the jet core and the intermittent dynamics of droplets across the turbulent-nonturbulent interface in the mixing layer, where dry air entrainment occurs. These phenomenologies strongly affect the overall vaporization process and lead to an impressive widening of the droplet size and vaporization rate distributions in the downstream evolution of the turbulent spray.

  17. Isotope dilution gas chromatography with mass spectrometry for the analysis of 4-octyl phenol, 4-nonylphenol, and bisphenol A in vegetable oils.

    PubMed

    Wu, Pinggu; Zhang, Liqun; Yang, Dajin; Zhang, Jing; Hu, Zhengyan; Wang, Liyuan; Ma, Bingjie

    2016-03-01

    By the combination of solid-phase extraction as well as isotope dilution gas chromatography with mass spectrometry, a sensitive and reliable method for the determination of endocrine-disrupting chemicals including bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils was established. The application of a silica/N-(n-propyl)ethylenediamine mixed solid-phase extraction cartridge achieved relatively low matrix effects for bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils. Experiments were designed to evaluate the effects of derivatization, and the extraction parameters were optimized. The estimated limits of detection and quantification for bisphenol A, 4-octylphenol, and 4-nonylphenol were 0.83 and 2.5 μg/kg, respectively. In a spiked experiment in vegetable oils, the recovery of the added bisphenol A was 97.5-110.3%, recovery of the added 4-octylphenol was 64.4-87.4%, and that of 4-nonylphenol was 68.2-89.3%. This sensitive method was then applied to real vegetable oil samples from Zhejiang Province of China, and none of the target compounds were detected. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A MODIFIED PROTEIN ASSAY FROM MICROGRAM TO LOW NANOGRAM LEVELS IN DILUTE SAMPLES

    PubMed Central

    Heda, Ghanshyam D.; Kunwar, Upasana; Heda, Rajiv P.

    2013-01-01

    In this paper we present a modified and improved protein assay that was previously described as ‘amidoschwarz assay’ by Schaffner and Weissmann (Anal. Biochem. 56, 1973, 502–514). Our improved protein assay is user-friendly and 30 to 40 times more sensitive than the earlier method. The assay was developed into 3 formats (maco, micro, and nanoassay) with TCA as protein precipitating agent; measuring up to 96 samples. The macro and micro formats of this assay require a single reagent staining with amido black of protein dots, bound to nitrocellulose membrane with lowest protein measurements to 1 μg and 0.1 μg respectively. The nanoassay on the other hand with combination staining of amido black followed by colloidal gold can extend the detection limit to 2.5 ng of protein. Protein concentrations were determined by densitometry and/or spectrophotometry. This assay is compatible with many ionic and non-ionic detergents. This improved protein assay provides an additional choice to researchers in measuring total protein concentration accurately in dilute biological samples as low as 0.125 μg/ml, prior to their biochemical analysis such as in comparative proteomics. PMID:24135655

  19. Effects of inertia on the steady shear rheology of concentrated emulsions: sign reversal of normal stress differences

    NASA Astrophysics Data System (ADS)

    Srivastava, Priyesh; Sarkar, Kausik

    2012-11-01

    The shear rheology of moderately concentrated emulsions (5-27% volume fraction) in the presence of inertia is numerically investigated. Typically, an emulsion of viscous drops experiences positive first normal stress difference (N1) and negative second normal stress difference (N2) , as has also been predicted by perturbative analysis (Choi-Schowalter model) and numerical simulation. However, recently using single drop results we have shown [Li and Sarkar, 2005, J. Rheo, 49, 1377] that introduction of inertia reverses the signs of the normal stress difference in the dilute limit. Here, we numerically investigate the effects of interactions between drops in a concentrated system. The simulation is validated against the dilute results as well as analytical relations. It also shows the reversal of signs for N1 and N2 for small Capillary numbers above a critical Reynolds number. The physics is explained by the inertia-induced orientation of the individual drops in shear. Increasing volume fraction increases the critical Reynolds number at which N1 and N2change sign. The breakdown of linearity with volume fraction with increasing concentration is also analyzed. Partially supported by NSF.

  20. Strong Relation between Muscle Mass Determined by D3-creatine Dilution, Physical Performance and Incidence of Falls and Mobility Limitations in a Prospective Cohort of Older Men.

    PubMed

    Cawthon, Peggy M; Orwoll, Eric S; Peters, Katherine E; Ensrud, Kristine E; Cauley, Jane A; Kado, Deborah M; Stefanick, Marcia L; Shikany, James M; Strotmeyer, Elsa S; Glynn, Nancy W; Caserotti, Paolo; Shankaran, Mahalakshmi; Hellerstein, Marc; Cummings, Steven R; Evans, William J

    2018-06-12

    Direct assessment of skeletal muscle mass in older adults is clinically challenging. Relationships between lean mass and late-life outcomes have been inconsistent. The D3-creatine dilution method provides a direct assessment of muscle mass. Muscle mass was assessed by D3-creatine (D3Cr) dilution in 1,382 men (mean age, 84.2 yrs). Participants completed the Short Physical Performance Battery (SPPB); usual walking speed (6 meters); and DXA lean mass. Men self-reported mobility limitations (difficulty walking 2-3 blocks or climbing 10 steps); recurrent falls (2+); and serious injurious falls in the subsequent year. Across quartiles of D3Cr muscle mass/body mass, multivariate linear models calculated means for SPPB and gait speed; multivariate logistic models calculated odds ratios for incident mobility limitations or falls. Compared to men in the highest quartile, those in the lowest quartile of D3Cr muscle mass/body mass had slower gait speed (Q1: 1.04 vs Q4: 1.17 m/s); lower SPPB (Q1: 8.4 vs Q4: 10.4 points); greater likelihood of incident serious injurious falls (OR Q1 vs Q4: 2.49, 95% CI: 1.37, 4.54); prevalent mobility limitation (OR Q1 vs Q4,: 6.1, 95%CI: 3.7, 10.3) and incident mobility limitation (OR Q1 vs Q4: 2.15 95% CI: 1.42, 3.26); p for trend <.001 for all. Results for incident recurrent falls were in the similar direction (p=0.156). DXA lean mass had weaker associations with the outcomes. Unlike DXA lean mass, low D3Cr muscle mass/body mass is strongly related to physical performance, mobility and incident injurious falls in older me.

  1. Pinch-off dynamics, extensional viscosity and relaxation time of dilute and ultradilute aqueous polymer solutions

    NASA Astrophysics Data System (ADS)

    Biagioli, Madeleine; Dinic, Jelena; Jimenez, Leidy Nallely; Sharma, Vivek

    Free surface flows and drop formation processes present in printing, jetting, spraying, and coating involve the development of columnar necks that undergo spontaneous surface-tension driven instability, thinning, and pinch-off. Stream-wise velocity gradients that arise within the thinning neck create and extensional flow field, which induces micro-structural changes within complex fluids that contribute elastic stresses, changing the thinning and pinch-off dynamics. In this contribution, we use dripping-onto-substrate (DoS) extensional rheometry technique for visualization and analysis of the pinch-off dynamics of dilute and ultra-dilute aqueous polyethylene oxide (PEO) solutions. Using a range of molecular weights, we study the effect of both elasticity and finite extensibility. Both effective relaxation time and the transient extensional viscosity are found to be strongly concentration-dependent even for highly dilute solutions.

  2. Effective equations for the precession dynamics of electron spins and electron-impurity correlations in diluted magnetic semiconductors

    NASA Astrophysics Data System (ADS)

    Cygorek, M.; Axt, V. M.

    2015-08-01

    Starting from a quantum kinetic theory for the spin dynamics in diluted magnetic semiconductors, we derive simplified equations that effectively describe the spin transfer between carriers and magnetic impurities for an arbitrary initial impurity magnetization. Taking the Markov limit of these effective equations, we obtain good quantitative agreement with the full quantum kinetic theory for the spin dynamics in bulk systems at high magnetic doping. In contrast, the standard rate description where the carrier-dopant interaction is treated according to Fermi’s golden rule, which involves the assumption of a short memory as well as a perturbative argument, has been shown previously to fail if the impurity magnetization is non-zero. The Markov limit of the effective equations is derived, assuming only a short memory, while higher order terms are still accounted for. These higher order terms represent the precession of the carrier-dopant correlations in the effective magnetic field due to the impurity spins. Numerical calculations show that the Markov limit of our effective equations reproduces the results of the full quantum kinetic theory very well. Furthermore, this limit allows for analytical solutions and for a physically transparent interpretation.

  3. Cloning of Plasmodium falciparum by single-cell sorting

    PubMed Central

    Miao, Jun; Li, Xiaolian; Cui, Liwang

    2010-01-01

    Malaria parasite cloning is traditionally carried out mainly by using the limiting dilution method, which is laborious, imprecise, and unable to distinguish multiply-infected RBCs. In this study, we used a parasite engineered to express green fluorescent protein (GFP) to evaluate a single-cell sorting method for rapidly cloning Plasmodium falciparum. By dividing a two dimensional scattergram from a cell sorter into 17 gates, we determined the parameters for isolating singly-infected erythrocytes and sorted them into individual cultures. Pre-gating of the engineered parasites for GFP allowed the isolation of almost 100% GFP-positive clones. Compared with the limiting dilution method, the number of parasite clones obtained by single-cell sorting was much higher. Molecular analyses showed that parasite isolates obtained by single-cell sorting were highly homogenous. This highly efficient single-cell sorting method should prove very useful for cloning both P. falciparum laboratory populations from genetic manipulation experiments and clinical samples. PMID:20435038

  4. Liquid helium cryostat with internal fluorescence detection for x-ray absorption studies in the 2-6 keV energy region

    NASA Astrophysics Data System (ADS)

    McFarlane Holman, Karen L.; Latimer, Matthew J.; Yachandra, Vittal K.

    2004-06-01

    X-ray absorption spectroscopy (XAS) in the intermediate x-ray region (2-6 keV) for dilute biological samples has been limited because of detector/flux limitations and inadequate cryogenic instrumentation. We have designed and constructed a new tailpiece/sample chamber for a commercially available liquid helium cooled cryostat which overcomes difficulties related to low fluorescence signals by using thin window materials and incorporating an internal photodiode detector. With the apparatus, XAS data at the Cl, S, and Ca K edges have been collected on frozen solutions and biological samples at temperatures down to 60 K. A separate chamber has been incorporated for collecting room-temperature spectra of standard compounds (for energy calibration purposes) which prevents contamination of the cryostat chamber and allows the sample to remain undisturbed, both important concerns for studying dilute and radiation-sensitive samples.

  5. SLDAssay: A software package and web tool for analyzing limiting dilution assays.

    PubMed

    Trumble, Ilana M; Allmon, Andrew G; Archin, Nancie M; Rigdon, Joseph; Francis, Owen; Baldoni, Pedro L; Hudgens, Michael G

    2017-11-01

    Serial limiting dilution (SLD) assays are used in many areas of infectious disease related research. This paper presents SLDAssay, a free and publicly available R software package and web tool for analyzing data from SLD assays. SLDAssay computes the maximum likelihood estimate (MLE) for the concentration of target cells, with corresponding exact and asymptotic confidence intervals. Exact and asymptotic goodness of fit p-values, and a bias-corrected (BC) MLE are also provided. No other publicly available software currently implements the BC MLE or the exact methods. For validation of SLDAssay, results from Myers et al. (1994) are replicated. Simulations demonstrate the BC MLE is less biased than the MLE. Additionally, simulations demonstrate that exact methods tend to give better confidence interval coverage and goodness-of-fit tests with lower type I error than the asymptotic methods. Additional advantages of using exact methods are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. FUEL EFFECTS ON COMBUSTION WITH EGR DILUTION IN SPARK IGNITED ENGINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szybist, James P

    The use of EGR as a diluent allows operation with an overall stoichiometric charge composition, and the addition of cooled EGR results in well-understood thermodynamic benefits for improved fuel consumption. This study investigates the effect of fuel on the combustion and emission response of EGR dilution in spark ignited engines. A 2.0 L GM Ecotec LNF engine equipped with the production side-mounted direct injection (DI) fueling system is used in this study. Ethanol, isooctane and certified gasoline are investigated with EGR from 0% to the EGR dilution tolerance. Constant BMEP at 2000 rpm was operated with varying CA50 from 8more » CAD to 16 CAD aTDCf. The results show that ethanol gives the largest EGR tolerance at a given combustion phasing, engine load and speed. The improved EGR dilution tolerance with ethanol is attributed to a faster flame speed, which manifests itself as shorter combustion duration. Data shows that the combustion stability limit occurs at a critical combustion duration that is fuel independent. Due to different flame speeds, this critical combustion duration occurs at different EGR levels for the different fuels.« less

  7. Microalgae treatment removes nutrients and reduces ecotoxicity of diluted piggery digestate.

    PubMed

    Franchino, Marta; Tigini, Valeria; Varese, Giovanna Cristina; Mussat Sartor, Rocco; Bona, Francesca

    2016-11-01

    Liquid digestate is considered as an important by-product of anaerobic digestion of agriculture wastes. Currently, it is very often directly spread on local agricultural land. Yet recently concerns on its environmental risk of this processing has begun to rise. On the other hand, investigations on the effectiveness of microalgae for wastewater treatment have started to consider also this complex matrix. In this study, we cultured the green alga Chlorella vulgaris in diluted digestate coming from the anaerobic digestion of pig slurry and corn, with the aim to significantly reduce its toxicity and its very high nutrient concentration. For this purpose, a battery of toxicity tests composed of four acute and two chronic bioassays was applied after the alga cultivation. Results were compared with those obtained in the initial characterization of the digestate. Results show that highly diluted piggery digestate can be a suitable medium for culturing microalgae, as we obtained a high removal efficiency (>90%) for ammonia, total nitrogen and phosphate, though after a few days phosphorus limitation occurred. Toxicity was significantly reduced for all the organisms tested. Possible solutions for optimizing this approach avoiding high dilution rates are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Multi-channel Auto-dilution System for Remote Continuous Monitoring of High Soil-CO2 Fluxes

    NASA Astrophysics Data System (ADS)

    Barr, J. L.; Amonette, J. E.

    2008-12-01

    We describe a novel field instrument that takes input from up to 27 soil flux chambers and measures flux using the steady-state method. CO2 concentrations are determined with an infrared gas analyzer (IRGA, 0- 3000 ppmv range) with corrections for temperature, barometric pressure, and moisture content. The concentrations are monitored during data collection and, if they exceed the range of the IRGA, a stepped dilution program is automatically implemented that allows up to 50-fold dilution of the incoming gas stream with N2 supplied by boil-off from a large dewar. The upper concentration limit of the system with dilution is extended to at least 150,000 ppmv CO2. The data are stored on a datalogger having a cellular modem connection that allows remote control of the system as well as transmittal of data. The system is designed to operate for six weeks with no on-site maintenance required. Longer periods are possible with modifications to allow on-site generation of N2 from air. Example data from a recent CO2 test injection at the Zero- Emission Research and Technology (ZERT) field site in Bozeman, MT are presented.

  9. Measurement of plasma unbound unconjugated bilirubin.

    PubMed

    Ahlfors, C E

    2000-03-15

    A method is described for measuring the unconjugated fraction of the unbound bilirubin concentration in plasma by combining the peroxidase method for determining unbound bilirubin with a diazo method for measuring conjugated and unconjugated bilirubin. The accuracy of the unbound bilirubin determination is improved by decreasing sample dilution, eliminating interference by conjugated bilirubin, monitoring changes in bilirubin concentration using diazo derivatives, and correcting for rate-limiting dissociation of bilirubin from albumin. The unbound unconjugated bilirubin concentration by the combined method in plasma from 20 jaundiced newborns was significantly greater than and poorly correlated with the unbound bilirubin determined by the existing peroxidase method (r = 0.7), possibly due to differences in sample dilution between the methods. The unbound unconjugated bilirubin was an unpredictable fraction of the unbound bilirubin in plasma samples from patients with similar total bilirubin concentrations but varying levels of conjugated bilirubin. A bilirubin-binding competitor was readily detected at a sample dilution typically used for the combined test but not at the dilution used for the existing peroxidase method. The combined method is ideally suited to measuring unbound unconjugated bilirubin in jaundiced human newborns or animal models of kernicterus. Copyright 2000 Academic Press.

  10. Linking manipulative experiments to field data to test the dilution effect.

    PubMed

    Venesky, Matthew D; Liu, Xuan; Sauer, Erin L; Rohr, Jason R

    2014-05-01

    The dilution effect, the hypothesis that biodiversity reduces disease risk, has received support in many systems. However, few dilution effect studies have linked mechanistic experiments to field patterns to establish both causality and ecological relevance. We conducted a series of laboratory experiments and tested the dilution effect hypothesis in an amphibian-Batrachochytrium dendrobatidis (Bd) system and tested for consistency between our laboratory experiments and field patterns of amphibian species richness, host identity and Bd prevalence. In our laboratory experiments, we show that tadpoles can filter feed Bd zoospores and that the degree of suspension feeding was positively associated with their dilution potential. The obligate suspension feeder, Gastrophryne carolinensis, generally diluted the risk of chytridiomycosis for tadpoles of Bufo terrestris and Hyla cinerea, whereas tadpoles of B. terrestris (an obligate benthos feeder) generally amplified infections for the other species. In addition, G. carolinensis reduced Bd abundance on H. cinerea more so in the presence than absence of B. terrestris and B. terrestris amplified Bd abundance on H. cinerea more so in the absence than presence of G. carolinensis. Also, when ignoring species identity, species richness was a significant negative predictor of Bd abundance. In our analysis of field data, the presence of Bufo spp. and Gastrophryne spp. were significant positive and negative predictors of Bd prevalence, respectively, even after controlling for climate, vegetation, anthropogenic factors (human footprint), species richness and sampling effort. These patterns of dilution and amplification supported our laboratory findings, demonstrating that the results are likely ecologically relevant. The results from our laboratory and field data support the dilution effect hypothesis and also suggest that dilution and amplification are predictable based on host traits. Our study is among the first to link manipulative experiments, in which a potential dilution mechanism is supported, with analyses of field data on species richness, host identity, spatial autocorrelation and disease prevalence. © 2013 The Authors. Journal of Animal Ecology © 2013 British Ecological Society.

  11. Separation and analysis of trace degradants in a pharmaceutical formulation using on-line capillary isotachophoresis-NMR.

    PubMed

    Eldridge, Stacie L; Almeida, Valentino K; Korir, Albert K; Larive, Cynthia K

    2007-11-15

    NMR spectroscopy is widely used in the pharmaceutical industry for the structure elucidation of pharmaceutical impurities, especially when coupled to a separation method, such as HPLC. However, NMR has relatively poor sensitivity compared with other techniques such as mass spectrometry, limiting its applicability in impurity analyses. This limitation is addressed here through the on-line coupling of microcoil NMR with capillary isotachophoresis (cITP), a separation method that can concentrate dilute components by 2-3 orders of magnitude. With this approach, 1H NMR spectra can be acquired for microgram (nanomole) quantities of trace impurities in a complex sample matrix. cITP-NMR was used in this work to isolate and detect 4-aminophenol (PAP) in an acetaminophen sample spiked at the 0.1% level, with no interference from the parent compound. Analysis of an acetaminophen thermal degradation sample revealed resonances of several degradation products in addition to PAP, confirming the effectiveness of on-line cITP-NMR for trace analyses of pharmaceutical formulations. Subsequent LC-MS/MS analysis provided complementary information for the structure elucidation of the unknown degradation products, which were dimers formed during the degradation process.

  12. DOSY Analysis of Micromolar Analytes: Resolving Dilute Mixtures by SABRE Hyperpolarization.

    PubMed

    Reile, Indrek; Aspers, Ruud L E G; Tyburn, Jean-Max; Kempf, James G; Feiters, Martin C; Rutjes, Floris P J T; Tessari, Marco

    2017-07-24

    DOSY is an NMR spectroscopy technique that resolves resonances according to the analytes' diffusion coefficients. It has found use in correlating NMR signals and estimating the number of components in mixtures. Applications of DOSY in dilute mixtures are, however, held back by excessively long measurement times. We demonstrate herein, how the enhanced NMR sensitivity provided by SABRE hyperpolarization allows DOSY analysis of low-micromolar mixtures, thus reducing the concentration requirements by at least 100-fold. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Trace determination of zinc by substoichiometric isotope dilution analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandhya, D.; Priya, S.; Subramanian, M.O.S.

    1996-09-01

    A radiometric method based on substoichiometric isotope dilution analysis using 1,10-phenanthroline and a substoichiometric amount of eosin was developed for determining trace amounts of zinc. Evaluation of various metal ion interferences shows that as little as 0.2 {mu}g Zn could be determined in an aqueous-phase volume of 60 mL. The method has been successfully applied to the determination of Zn in city waste incineration ash, cadmium metal, Fourts-B tablets, Boro-plus ointment, and magnesium alloy samples. 12 refs., 3 figs., 3 tabs.

  14. The effects of inhomogeneous boundary dilution on the coating flow of an anti-HIV microbicide vehicle

    NASA Astrophysics Data System (ADS)

    Tasoglu, Savas; Peters, Jennifer J.; Park, Su Chan; Verguet, Stéphane; Katz, David F.; Szeri, Andrew J.

    2011-09-01

    A recent study in South Africa has confirmed, for the first time, that a vaginal gel formulation of the antiretroviral drug Tenofovir, when topically applied, significantly inhibits sexual HIV transmission to women [Karim et al., Science 329, 1168 (2010)]. However, the gel for this drug and anti-HIV microbicide gels in general have not been designed using an understanding of how gel spreading and retention in the vagina govern successful drug delivery. Elastohydrodynamic lubrication theory can be applied to model spreading of microbicide gels [Szeri et al., Phys. Fluids 20, 083101 (2008)]. This should incorporate the full rheological behavior of a gel, including how rheological properties change due to contact with, and dilution by, ambient vaginal fluids. Here, we extend our initial analysis, incorporating the effects of gel dilution due to contact with vaginal fluid produced at the gel-tissue interface. Our original model is supplemented with a convective-diffusive transport equation to characterize water transport into the gel and, thus, local gel dilution. The problem is solved using a multi-step scheme in a moving domain. The association between local dilution of gel and rheological properties is obtained experimentally, delineating the way constitutive parameters of a shear-thinning gel are modified by dilution. Results show that dilution accelerates the coating flow by creating a slippery region near the vaginal wall akin to a dilution boundary layer, especially if the boundary flux exceeds a certain value. On the other hand, if the diffusion coefficient of boundary fluid is increased, the slippery region diminishes in extent and the overall rate of gel spreading decreases.

  15. Cooked carrots volatiles. AEDA and odor activity comparisons. Identification of Linden Ether as an important aroma component

    USDA-ARS?s Scientific Manuscript database

    MS with GC-RI evidence was found for the presence of Linden ether in cooked carrot. Evaluation of the GC effluent from cooked carrot volatiles using Aroma Extract Dilution Analysis (AEDA) found Linden ether with the highest Flavor Dilution (FD) factor. Others with 10 fold lower FD factors were B-i...

  16. Characterization of the key aroma compounds in beef extract using aroma extract dilution analysis.

    PubMed

    Takakura, Yukiko; Sakamoto, Tomohiro; Hirai, Sachi; Masuzawa, Takuya; Wakabayashi, Hidehiko; Nishimura, Toshihide

    2014-05-01

    Aroma extract dilution analysis (AEDA) of an ether extract prepared from beef extract (BE) and subsequent identification experiments led to the determination of seven aroma-active compounds in the flavor dilution (FD) factor range of 32-128. Omission experiments to select the most aroma-active compounds from the seven aroma compounds suggested that 2,3,5-trimethyl pyrazine, 1-octen-3-ol, 3-methylbutanoic acid, and 4-hydroxy-2,5-dimethyl-3(2H)-furanone were the main active compounds contributing to the aroma of BE. Aroma recombination, addition, and omission experiments of the four aroma compounds in taste-reconstituted BE showed that each compound had an individual aroma profile. A comparison of the overall aroma between this recombination mixture and BE showed a high similarity, suggesting that the key aroma compounds had been identified successfully. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Isotope-dilution gas chromatography-mass spectrometry coupled with injection-port butylation for the determination of 4-t-octylphenol, 4-nonylphenols and bisphenol A in human urine.

    PubMed

    Chung, Shuang-Hung; Ding, Wang-Hsien

    2018-02-05

    An analytical method that utilizes isotope-dilution gas chromatography-mass spectrometry (ID-GC-MS) coupled with injection-port butylation was developed. The method was validated, and confirmed to be able to determine the presence of three commonly detected endocrine-disrupting chemicals (EDCs: 4-tert-octylphenol (4-t-OP), 4-nonylphenols (4-NPs) and bisphenol A (BPA)) in human urine with high precision and accuracy. After sample preparation by solid-phase extraction, the extract was introduced into GC-MS via injection-port butylation. The butylated target analytes were identified and quantified by using ion-trap mass spectrometry operating in the selected-ion-storage mode, and employing the measurement of peak area ratios of the butylated target analytes and labeled-analogues in the samples and calibration standards. The labeled-analogues were also used to correct the variations associated with the analysis and matrix effect. The limits of quantitation (LOQs) ranged from 0.1 to 0.3ng/mL. High precisions for both intra- and inter-day analysis ranged from 1 to 6%, and excellent accuracy (mean recovery) ranged from 92 to 105% on two concentration levels. In human urine, the total concentrations of three selected EDCs varied from 1.28 to 7.14ng/mL. 4-NPs were detected within all collected samples. The developed method allows accurate analysis of trace-level of EDCs in urine, and these target EDCs could act as useful biomarkers to assess exposure in biomonitoring studies and programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. High-accuracy measurements of N2O concentration and site-specific nitrogen isotopes in small or high concentration samples

    NASA Astrophysics Data System (ADS)

    Palmer, M. R.; Arata, C.; Huang, K.

    2014-12-01

    Nitrous oxide (N2O) gas is among the major contributors to global warming and ozone depletion in stratosphere. Quantitative estimate of N­2O production in various pathways and N­2O fluxes across different reservoirs is the key to understanding the role of N­2O in the global change. To achieve this goal, accurate and concurrent measurement of both N2O concentration ([N2O]) and its site-specific isotopic composition (SP-δ15N), namely δ15Nα and δ15Nβ, is desired. Recent developments in Cavity Ring-Down Spectroscopy (CRDS) have enabled high precision measurements of [N2O] and SP-δ15N of a continuous gas flow. However, many N­­2O samples are discrete with limited volume (< 500 ml), and/or high [N2O] (> 2 ppm), and are not suitable for direct measurements by CRDS. Here we present results of a Small Sample Isotope Module 2 (SSIM2) which is coupled to and automatically coordinated with a Picarro isotopic N2O CRDS analyzer to handle and measure high concentration and/or small volume samples. The SSIM2 requires 20 ml of sample per analysis, and transfers the sample to the CRDS for high precision measurement. When the sample injection is < 20 ml, a zero gas is optionally filled to make up the volume. We used the SSIM2 to dilute high [N2O] samples and < 20 ml samples, and tested the effect of dilution on the measured SP-δ15N. In addition, we employed and tested a newly developed double injection method for samples adequate for two 20 ml injections. After the SSIM2 and the CRDS cavity was primed with the first injection, the second injection, which has negligible dilution of the sample, can be accurately measured for both [N2O] and SP-δ15N. Results of these experiments indicate that the precision of SSIM2-CRDS is similar to that of the continuous measurements using the CRDS alone, and that dilution has minimal effect on SP-δ15N, as along as the [N2O] is > 300 ppb after dilution. Overall, the precision of SP-δ15N measured using the SSIM2 is < 0.5 ‰.

  19. Development of a micromanipulation method for single cell isolation of prokaryotes and its application in food safety.

    PubMed

    Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud

    2018-01-01

    For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.

  20. Penetrable square-well fluids: exact results in one dimension.

    PubMed

    Santos, Andrés; Fantoni, Riccardo; Giacometti, Achille

    2008-05-01

    We introduce a model of attractive penetrable spheres by adding a short-range attractive square well outside a penetrable core, and we provide a detailed analysis of structural and thermodynamical properties in one dimension using the exact impenetrable counterpart as a starting point. The model is expected to describe star polymers in regimes of good and moderate solvent under dilute conditions. We derive the exact coefficients of a low-density expansion up to second order for the radial distribution function and up to fourth order in the virial expansion. These exact results are used as a benchmark to test the reliability of approximate theories (Percus-Yevick and hypernetted chain). Notwithstanding the lack of an exact solution for arbitrary densities, our results are expected to be rather precise within a wide range of temperatures and densities. A detailed analysis of some limiting cases is carried out. In particular, we provide a complete solution of the sticky penetrable-sphere model in one dimension up to the same order in density. The issue of Ruelle's thermodynamics stability is analyzed and the region of a well-defined thermodynamic limit is identified.

  1. Straightforward analytical method to determine opium alkaloids in poppy seeds and bakery products.

    PubMed

    López, Patricia; Pereboom-de Fauw, Diana P K H; Mulder, Patrick P J; Spanjer, Martien; de Stoppelaar, Joyce; Mol, Hans G J; de Nijs, Monique

    2018-03-01

    A straightforward method to determine the content of six opium alkaloids (morphine, codeine, thebaine, noscapine, papaverine and narceine) in poppy seeds and bakery products was developed and validated down to a limit of quantification (LOQ) of 0.1mg/kg. The method was based on extraction with acetonitrile/water/formic acid, ten-fold dilution and analysis by LC-MS/MS using a pH 10 carbonate buffer. The method was applied for the analysis of 41 samples collected in 2015 in the Netherlands and Germany. All samples contained morphine ranging from 0.2 to 240mg/kg. The levels of codeine and thebaine ranged from below LOQ to 348mg/kg and from below LOQ to 106mg/kg, respectively. Sixty percent of the samples exceeded the guidance reference value of 4mg/kg of morphine set by BfR in Germany, whereas 25% of the samples did not comply with the limits set for morphine, codeine, thebaine and noscapine by Hungarian legislation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. TEMORA 1: A new zircon standard for Phanerozoic U-Pb geochronology

    USGS Publications Warehouse

    Black, L.P.; Kamo, S.L.; Allen, C.M.; Aleinikoff, J.N.; Davis, D.W.; Korsch, R.J.; Foudoulis, C.

    2003-01-01

    The role of the standard is critical to the derivation of reliable U-Pb zircon ages by micro-beam analysis. For maximum reliability, it is critically important that the utilised standard be homogeneous at all scales of analysis. It is equally important that the standard has been precisely and accurately dated by an independent technique. This study reports the emergence of a new zircon standard that meets those criteria, as demonstrated by Sensitive High Resolution Ion MicroProbe (SHRIMP), isotope dilution thermal ionisation mass-spectrometry (IDTIMS) and excimer laser ablation- inductively coupled plasma-mass-spectrometry (ELA-ICP-MS) documentation. The TEMORA 1 zircon standard derives from the Middledale Gabbroic Diorite, a high-level mafic stock within the Palaeozoic Lachlan Orogen of eastern Australia. Its 206Pb/238U IDTIMS age has been determined to be 416.75??0.24 Ma (95% confidence limits), based on measurement errors alone. Spike-calibration uncertainty limits the accuracy to 416.8??1.1 Ma for U-Pb intercomparisons between different laboratories that do not use a common spike. ?? 2003 Published by Elsevier Science B.V. All rights reserved.

  3. Key Aroma Compounds in Lippia dulcis (Dushi Button).

    PubMed

    Schmitt, Rainer; Cappi, Michael; Pollner, Gwendola; Greger, Veronika

    2018-03-14

    An aroma extract dilution analysis (AEDA) applied on aroma extracts prepared from the edible flower Dushi Button ( Lippia dulcis) resulted in the detection of 34 odor-active compounds. The highest flavor dilution (FD) factors were determined for methyl 2-methylbutanoate, ethyl 2-methylbutanoate, 4-mercapto-4-methyl-2-pentanone, an unknown caramel-like compound, and vanillin. Quantitative measurements performed by application of stable isotope dilution assays (SIDA), followed by a calculation of odor activity values (OAVs), resulted in the revelation of 4-mercapto-4-methyl-2-pentanone, linalool, myrcene, ethyl 2-methylbutanoate, methyl 2-methylbutanoate, and ( Z)-3-hexenal as important contributors to the flavor of Dushi Buttons.

  4. Linear and nonlinear ion-acoustic waves in nonrelativistic quantum plasmas with arbitrary degeneracy.

    PubMed

    Haas, Fernando; Mahmood, Shahzad

    2015-11-01

    Linear and nonlinear ion-acoustic waves are studied in a fluid model for nonrelativistic, unmagnetized quantum plasma with electrons with an arbitrary degeneracy degree. The equation of state for electrons follows from a local Fermi-Dirac distribution function and applies equally well both to fully degenerate and classical, nondegenerate limits. Ions are assumed to be cold. Quantum diffraction effects through the Bohm potential are also taken into account. A general coupling parameter valid for dilute and dense plasmas is proposed. The linear dispersion relation of the ion-acoustic waves is obtained and the ion-acoustic speed is discussed for the limiting cases of extremely dense or dilute systems. In the long-wavelength limit, the results agree with quantum kinetic theory. Using the reductive perturbation method, the appropriate Korteweg-de Vries equation for weakly nonlinear solutions is obtained and the corresponding soliton propagation is analyzed. It is found that soliton hump and dip structures are formed depending on the value of the quantum parameter for the degenerate electrons, which affect the phase velocities in the dispersive medium.

  5. Linear and nonlinear ion-acoustic waves in nonrelativistic quantum plasmas with arbitrary degeneracy

    NASA Astrophysics Data System (ADS)

    Haas, Fernando; Mahmood, Shahzad

    2015-11-01

    Linear and nonlinear ion-acoustic waves are studied in a fluid model for nonrelativistic, unmagnetized quantum plasma with electrons with an arbitrary degeneracy degree. The equation of state for electrons follows from a local Fermi-Dirac distribution function and applies equally well both to fully degenerate and classical, nondegenerate limits. Ions are assumed to be cold. Quantum diffraction effects through the Bohm potential are also taken into account. A general coupling parameter valid for dilute and dense plasmas is proposed. The linear dispersion relation of the ion-acoustic waves is obtained and the ion-acoustic speed is discussed for the limiting cases of extremely dense or dilute systems. In the long-wavelength limit, the results agree with quantum kinetic theory. Using the reductive perturbation method, the appropriate Korteweg-de Vries equation for weakly nonlinear solutions is obtained and the corresponding soliton propagation is analyzed. It is found that soliton hump and dip structures are formed depending on the value of the quantum parameter for the degenerate electrons, which affect the phase velocities in the dispersive medium.

  6. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  7. National Risk Management Research Laboratory (NRMRL) Microbial Research

    EPA Science Inventory

    Experimental design: Three host-specific PCR assays were tested against fecal and water samples. Host-specificity assays were performed against targeted and nontargeted fecal sources. Detection limits were performed against diluted fecal and water DNA extracts. Groundwater an...

  8. Investigations on Mg-borate kinetics and mechanisms during evaporation, dilution and crystallization by Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Peng, Jiaoyu; Chen, Jing; Dong, Yaping; Li, Wu

    2018-06-01

    Raman spectra of boron-concentrated, diluted, and corresponding mother solutions of brine were recorded at 298.15 K. The main polyborate anions present and their interactions in brine during evaporation and dilution were proposed according to the Raman spectra. The polyborate anions B(OH)3, B3O3(OH)4-, B5O6(OH)4-, and B6O7(OH)62- were found to be the main forms in boron-concentrated brine with B3O3(OH)4- ion being the principal form. Diluting brines with water accelerated depolymerization of B5O6(OH)4- and B6O7(OH)62- anions into B(OH)3 and B3O3(OH)4- ions and generated OH- ions, causing the pH of the solutions to increase from 4.2 to almost 8.0. Mg-borates precipitated from all diluted solutions could be classified as either hexaborates or triborates. A mechanism of solid phase transformation was also proposed and discussed based on Raman spectra analysis and solid species and solution pH data.

  9. Novel method for on-road emission factor measurements using a plume capture trailer.

    PubMed

    Morawska, L; Ristovski, Z D; Johnson, G R; Jayaratne, E R; Mengersen, K

    2007-01-15

    The method outlined provides for emission factor measurements to be made for unmodified vehicles driving under real world conditions at minimal cost. The method consists of a plume capture trailer towed behind a test vehicle. The trailer collects a sample of the naturally diluted plume in a 200 L conductive bag and this is delivered immediately to a mobile laboratory for subsequent analysis of particulate and gaseous emissions. The method offers low test turnaround times with the potential to complete much larger numbers of emission factor measurements than have been possible using dynamometer testing. Samples can be collected at distances up to 3 m from the exhaust pipe allowing investigation of early dilution processes. Particle size distribution measurements, as well as particle number and mass emission factor measurements, based on naturally diluted plumes are presented. A dilution profile relating the plume dilution ratio to distance from the vehicle tail pipe for a diesel passenger vehicle is also presented. Such profiles are an essential input for new mechanistic roadway air quality models.

  10. Analysis of boron dilution in a four-loop PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, J.G.; Sha, W.T.

    1995-12-31

    Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plantmore » is at hot standby and the reactor coolant system has been heated up to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated.« less

  11. Stability of florfenicol in drinking water.

    PubMed

    Hayes, John M; Eichman, Jonathan; Katz, Terry; Gilewicz, Rosalia

    2003-01-01

    Florfenicol, a broad-spectrum antibiotic, is being developed for veterinary application as an oral concentrate intended for dilution with drinking water. When a drug product is dosed via drinking water in a farm setting, a number of variables, including pH, chlorine content, hardness of the water used for dilution, and container material, may affect its stability, leading to a decrease in drug potency. The stability of florfenicol after dilution of Florfenicol Drinking Water Concentrate Oral Solution, 23 mg/mL, with drinking water was studied. A stability-indicating, validated liquid chromatographic method was used to evaluate florfenicol stability at 25 degrees C at 5, 10, and 24 h after dilution. The results indicate that florfenicol is stable under a range of simulated field conditions, including various pipe materials and conditions of hard or soft and chlorinated or nonchlorinated water at low or high pH. Significant degradation (> 10%) was observed only for isolated combinations in galvanized pipes. Analysis indicated that the florfenicol concentration in 8 of the 12 water samples stored in galvanized pipes remained above 90% of the initial concentration (100 mg/L) for 24 h after dilution.

  12. Numerical simulations to assess the tracer dilution method for measurement of landfill methane emissions.

    PubMed

    Taylor, Diane M; Chow, Fotini K; Delkash, Madjid; Imhoff, Paul T

    2016-10-01

    Landfills are a significant contributor to anthropogenic methane emissions, but measuring these emissions can be challenging. This work uses numerical simulations to assess the accuracy of the tracer dilution method, which is used to estimate landfill emissions. Atmospheric dispersion simulations with the Weather Research and Forecast model (WRF) are run over Sandtown Landfill in Delaware, USA, using observation data to validate the meteorological model output. A steady landfill methane emissions rate is used in the model, and methane and tracer gas concentrations are collected along various transects downwind from the landfill for use in the tracer dilution method. The calculated methane emissions are compared to the methane emissions rate used in the model to find the percent error of the tracer dilution method for each simulation. The roles of different factors are examined: measurement distance from the landfill, transect angle relative to the wind direction, speed of the transect vehicle, tracer placement relative to the hot spot of methane emissions, complexity of topography, and wind direction. Results show that percent error generally decreases with distance from the landfill, where the tracer and methane plumes become well mixed. Tracer placement has the largest effect on percent error, and topography and wind direction both have significant effects, with measurement errors ranging from -12% to 42% over all simulations. Transect angle and transect speed have small to negligible effects on the accuracy of the tracer dilution method. These tracer dilution method simulations provide insight into measurement errors that might occur in the field, enhance understanding of the method's limitations, and aid interpretation of field data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Laser-Excited Atomic Fluorescence and Ionization in a Graphite Furnace for the Determination of Metals and Nonmetals

    NASA Astrophysics Data System (ADS)

    Butcher, David James

    1990-01-01

    Here is reported novel instrumentation for atomic spectrometry that combined the use of a pulsed laser system as the light source and an electrothermal atomizer as the atom cell. The main goal of the research was to develop instrumentation that was more sensitive for elemental analysis than commercially available instruments and could be used to determine elements in real sample matrices. Laser excited atomic fluorescence spectrometry (LEAFS) in an electrothermal atomizer (ETA) was compared to ETA atomic absorption spectrometry (AAS) for the determination of thallium, manganese, and lead in food and agricultural standard reference materials (SRMs). Compared to ETA AAS, ETA LEAFS has a longer linear dynamic range (LDR) (5-7 orders of magnitude compared to 2-3 orders of magnitude) and higher sensitivity (10 ^{-16} to 10^{ -14} g as compared to 10^{ -13} to 10^{-11} g). Consequently, ETA LEAFS allows elemental analysis to be done over a wider range of concentrations with less dilution steps. Thallium was accurately determined in biological samples by ETA LEAFS at amounts five to one hundred times below the ETA AAS detection limit. ETA AAS and ETA LEAFS were compared for the determination of lead and manganese, and in general, the accuracies and precisions of ETA AAS were the same, with typical precisions between 3% and 6%. Fluorine was determined using laser excited molecular fluorescence spectrometry (LEMOFS) in an ETA. Molecular fluorescence from magnesium fluoride was collected, and the detection limit of 0.3 pg fluorine was two to six orders of magnitude more sensitive than other methods commonly used for the determination of fluorine. Significant interferences from ions were observed, but the sensitivity was high enough that fluorine could be determined in freeze dried urine SRMs by diluting the samples by a factor of one hundred to remove the interferences. Laser enhanced ionization (LEI) in an ETA was used for the determination of metals. For thallium, indium, and lithium, detection limits between 0.7 and 2 pg were obtained, with an LDR of 3.5 orders of magnitude. Sodium was shown to severely depress the indium LEI signal in an ETA.

  14. L-edge sum rule analysis on 3d transition metal sites: from d 10 to d 0 and towards application to extremely dilute metallo-enzymes

    DOE PAGES

    Wang, Hongxin; Friedrich, Stephan; Li, Lei; ...

    2018-02-13

    According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0. In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noisemore » ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d0 to a closed shell 3d 10; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. As a result, this study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.« less

  15. L-edge sum rule analysis on 3d transition metal sites: from d 10 to d 0 and towards application to extremely dilute metallo-enzymes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hongxin; Friedrich, Stephan; Li, Lei

    According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0. In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noisemore » ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d0 to a closed shell 3d 10; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. As a result, this study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.« less

  16. Mixed aqueous solutions as dilution media in the determination of residual solvents by static headspace gas chromatography.

    PubMed

    D'Autry, Ward; Zheng, Chao; Wolfs, Kris; Yarramraju, Sitaramaraju; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2011-06-01

    Static headspace (HS) sampling has been commonly used to test for volatile organic chemicals, usually referred to as residual solvents (RS) in pharmaceuticals. If the sample is not soluble in water, organic solvents are used. However, these seriously reduce the sensitivity in the determination of some RS. Here, mixed aqueous dilution media (a mixture of water and an organic solvent like dimethyl formamide, dimethyl sulfoxide or dimethyl acetamide) were studied as alternative media for static HS-gas chromatographic analysis. Although it has been known that mixed aqueous dilution media can often improve sensitivity for many RS, this study used a systematic approach to investigate phase volumes and the organic content in the HS sampling media. Reference solutions using 18 different class 1, 2 and 3 RS were evaluated. The effect of salt addition was also studied in this work. A significant increase in the peak area was observed for all RS using mixed aqueous dilution media, when compared with organic solvents alone. Matrix effects related to the mixed aqueous dilution media were also investigated and reported. Repeatability and linearity obtained with mixed aqueous dilution media were found to be similar to those observed with pure organic solvents. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Point-by-point compositional analysis for atom probe tomography.

    PubMed

    Stephenson, Leigh T; Ceguerra, Anna V; Li, Tong; Rojhirunsakool, Tanaporn; Nag, Soumya; Banerjee, Rajarshi; Cairney, Julie M; Ringer, Simon P

    2014-01-01

    This new alternate approach to data processing for analyses that traditionally employed grid-based counting methods is necessary because it removes a user-imposed coordinate system that not only limits an analysis but also may introduce errors. We have modified the widely used "binomial" analysis for APT data by replacing grid-based counting with coordinate-independent nearest neighbour identification, improving the measurements and the statistics obtained, allowing quantitative analysis of smaller datasets, and datasets from non-dilute solid solutions. It also allows better visualisation of compositional fluctuations in the data. Our modifications include:.•using spherical k-atom blocks identified by each detected atom's first k nearest neighbours.•3D data visualisation of block composition and nearest neighbour anisotropy.•using z-statistics to directly compare experimental and expected composition curves. Similar modifications may be made to other grid-based counting analyses (contingency table, Langer-Bar-on-Miller, sinusoidal model) and could be instrumental in developing novel data visualisation options.

  18. Comparison of Agar Dilution, Disk Diffusion, MicroScan, and Vitek Antimicrobial Susceptibility Testing Methods to Broth Microdilution for Detection of Fluoroquinolone-Resistant Isolates of the Family Enterobacteriaceae

    PubMed Central

    Steward, Christine D.; Stocker, Sheila A.; Swenson, Jana M.; O’Hara, Caroline M.; Edwards, Jonathan R.; Gaynes, Robert P.; McGowan, John E.; Tenover, Fred C.

    1999-01-01

    Fluoroquinolone resistance appears to be increasing in many species of bacteria, particularly in those causing nosocomial infections. However, the accuracy of some antimicrobial susceptibility testing methods for detecting fluoroquinolone resistance remains uncertain. Therefore, we compared the accuracy of the results of agar dilution, disk diffusion, MicroScan Walk Away Neg Combo 15 conventional panels, and Vitek GNS-F7 cards to the accuracy of the results of the broth microdilution reference method for detection of ciprofloxacin and ofloxacin resistance in 195 clinical isolates of the family Enterobacteriaceae collected from six U.S. hospitals for a national surveillance project (Project ICARE [Intensive Care Antimicrobial Resistance Epidemiology]). For ciprofloxacin, very major error rates were 0% (disk diffusion and MicroScan), 0.9% (agar dilution), and 2.7% (Vitek), while major error rates ranged from 0% (agar dilution) to 3.7% (MicroScan and Vitek). Minor error rates ranged from 12.3% (agar dilution) to 20.5% (MicroScan). For ofloxacin, no very major errors were observed, and major errors were noted only with MicroScan (3.7% major error rate). Minor error rates ranged from 8.2% (agar dilution) to 18.5% (Vitek). Minor errors for all methods were substantially reduced when results with MICs within ±1 dilution of the broth microdilution reference MIC were excluded from analysis. However, the high number of minor errors by all test systems remains a concern. PMID:9986809

  19. Randomly diluted xy and resistor networks near the percolation threshold

    NASA Astrophysics Data System (ADS)

    Harris, A. B.; Lubensky, T. C.

    1987-05-01

    A formulation based on that of Stephen for randomly diluted systems near the percolation threshold is analyzed in detail. By careful consideration of various limiting procedures, a treatment of xy spin models and resistor networks is given which shows that previous calculations (which indicate that these systems having continuous symmetry have the same crossover exponents as the Ising model) are in error. By studying the limit wherein the energy gap goes to zero, we exhibit the mathematical mechanism which leads to qualitatively different results for xy-like as contrasted to Ising-like systems. A distinctive feature of the results is that there is an infinite sequence of crossover exponents needed to completely describe the probability distribution for R(x,x'), the resistance between sites x and x'. Because of the difference in symmetry between the xy model and the resistor network, the former has an infinite sequence of crossover exponents in addition to those of the resistor network. The first crossover exponent φ1=1+ɛ/42 governs the scaling behavior of R(x,x') with ||x-x'||≡r: [R(x,x')]c~xφ1/ν, where [ ]c indicates a conditional average, subject to x and x' being in the same cluster, ν is the correlation length exponent for percolation, and ɛ=6-d, where d is the spatial dimensionality. We give a detailed analysis of the scaling properties of the bulk conductivity and the anomalous diffusion constant introduced by Gefen et al. Our results show conclusively that the Alexander-Orbach conjecture, while numerically quite accurate, is not exact, at least in high spatial dimension. We also evaluate various amplitude ratios associated with susceptibilities, χn involving the nth power of the resistance R(x,x'), e.g., &χ2χ0/χ21=2[1+(19ɛ/420)]. In an appendix we outline how the calculation can be extended to treat the diluted m-component spin model for m>2. As expected, the results for φ1 remain valid for m>2. The techniques described here have led to several recent calculations of various infinite families of exponents.

  20. Establishment of gold-quartz standard GQS-1

    USGS Publications Warehouse

    Millard, Hugh T.; Marinenko, John; McLane, John E.

    1969-01-01

    A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.

  1. A New Flow Control Technique Using Diluted Epinephrine in the N-butyl-2-cyanoacrylate Embolization of Visceral Artery Pseudoaneurysms Secondary to Chronic Pancreatitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp; Yamagami, Takuji; Takeuchi, Yoshito

    2012-08-15

    Although n-butyl-2-cyanoacrylate (NBCA) has been used as an effective liquid embolization material, its indication for pseudoaneurysms has seemingly been limited because of the technical difficulties of using NBCA, such as reflux to the parent artery and causing significant infarction. Thus, considerable skill in using NBCA or a device to control blood flow during its polymerization is required to achieve embolization without severe complications. We report our new technique for controlling blood flow using diluted epinephrine in transcatheter arterial NBCA embolization of five pseudoaneurysms in four cases secondary to hemosuccus pancreaticus.

  2. Metallic Hydrogen - Potentially a High Energy Rocket Propellant

    NASA Technical Reports Server (NTRS)

    Cole, John; Silvera, Ike

    2007-01-01

    Pure metallic hydrogen is predicted to have a specific impulse (Isp) of 1700 seconds, but the reaction temperature is too high for current engine materials. Diluting metallic hydrogen with liquid hydrogen can reduce the reaction temperature to levels compatible with current material limits and still provide an Isp greater than 900 s. Metallic hydrogen has not yet been produced on earth, but experimental techniques exist that may change this situation. This paper will provide a brief description of metallic hydrogen and the status of experiments that may soon produce detectable quantities of this material in the lab. Also provided are some characteristics for diluted metallic hydrogen engines and launch vehicles.

  3. Validity of the methods to assess body fat in children and adolescents using multi-compartment models as the reference method: a systematic review.

    PubMed

    Silva, Danilo R P; Ribeiro, Alex S; Pavão, Fernando H; Ronque, Enio R V; Avelar, Ademar; Silva, Analiza M; Cyrino, Edilson S

    2013-01-01

    To analyze the validity of methods to assess body fat in children and adolescents using a systematic review. The search was conducted by two independent researchers using the MEDLINE, BioMed Central, SciELO and LILACS electronic databases. For inclusion, the articles should be written in English or Portuguese, and must have used multi-compartment models as the criterion measure of the model, with body fat measurement of whole body in non-athlete children and adolescents. A preliminary search resulted in 832 studies. After all selection steps were performed, 12 articles were included. The selected studies were published between 1997 and 2010, whose samples consisted of children and adolescents with levels of relative body fat ranging from 20.7% to 41.4%. The methods used were: dual energy X-ray absorptiometry (58.3%), isotope dilution (41.6%), skinfold thickness (33.3%), hydrostatic weighing (25%), bioelectrical impedance analysis (25%), air displacement plethysmography (16.6%), and total body electrical conductivity (8.3%). Based on the analysis of the studies, isotope dilution and air displacement plethysmography methods were the most reliable, despite the limited number of studies. As for clinical use or for population-based studies, the equation of Slaughter et al. (1998), which uses the triceps and subscapular skinfolds thickness, showed the best results for assessment of body fat in this population. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  4. Quantitation of DNA adducts by stable isotope dilution mass spectrometry

    PubMed Central

    Tretyakova, Natalia; Goggin, Melissa; Janis, Gregory

    2012-01-01

    Exposure to endogenous and exogenous chemicals can lead to the formation of structurally modified DNA bases (DNA adducts). If not repaired, these nucleobase lesions can cause polymerase errors during DNA replication, leading to heritable mutations potentially contributing to the development of cancer. Due to their critical role in cancer initiation, DNA adducts represent mechanism-based biomarkers of carcinogen exposure, and their quantitation is particularly useful for cancer risk assessment. DNA adducts are also valuable in mechanistic studies linking tumorigenic effects of environmental and industrial carcinogens to specific electrophilic species generated from their metabolism. While multiple experimental methodologies have been developed for DNA adduct analysis in biological samples – including immunoassay, HPLC, and 32P-postlabeling – isotope dilution high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) generally has superior selectivity, sensitivity, accuracy, and reproducibility. As typical DNA adducts concentrations in biological samples are between 0.01 – 10 adducts per 108 normal nucleotides, ultrasensitive HPLC-ESI-MS/MS methodologies are required for their analysis. Recent developments in analytical separations and biological mass spectrometry – especially nanoflow HPLC, nanospray ionization MS, chip-MS, and high resolution MS – have pushed the limits of analytical HPLC-ESI-MS/MS methodologies for DNA adducts, allowing researchers to accurately measure their concentrations in biological samples from patients treated with DNA alkylating drugs and in populations exposed to carcinogens from urban air, drinking water, cooked food, alcohol, and cigarette smoke. PMID:22827593

  5. Microwave-assisted deuterium exchange: the convenient preparation of isotopically labelled analogues for stable isotope dilution analysis of volatile wine phenols.

    PubMed

    Crump, Anna M; Sefton, Mark A; Wilkinson, Kerry L

    2014-11-01

    This study reports the convenient, low cost, one-step synthesis of labelled analogues of six volatile phenols, guaiacol, 4-methylguaiacol, 4-ethylguaiacol, 4-ethylphenol, eugenol and vanillin, using microwave-assisted deuterium exchange, for use as internal standards for stable isotope dilution analysis. The current method improves on previous strategies in that it enables incorporation of deuterium atoms on the aromatic ring, thereby ensuring retention of the isotope label during mass spectrometry fragmentation. When used as standards for SIDA, these labelled volatile phenols will improve the accuracy and reproducibility of quantitative food and beverage analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Amnioinfusion for meconium-stained liquor in labour.

    PubMed

    Hofmeyr, G Justus; Xu, Hairong

    2010-01-20

    Amnioinfusion is thought to dilute meconium present in the amniotic fluid and so reduce the risk of meconium aspiration. To assess the effects of amnioinfusion for meconium-stained liquor on perinatal outcome. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (May 2009). Randomised trials comparing amnioinfusion with no amnioinfusion for women in labour with moderate or thick meconium-staining of the amniotic fluid. Two review authors assessed eligibility and trial quality, and extracted data, independently. Thirteen studies of variable quality (4143 women) are included.Subgroup analysis was performed for studies from settings with limited facilities to monitor the baby's condition during labour and intervene effectively, and settings with standard peripartum surveillance.Settings with standard peripartum surveillance: there was considerable heterogeneity for several outcomes. There was no significant reduction in the primary outcomes meconium aspiration syndrome, perinatal death or severe morbidity, and maternal death or severe morbidity. There was a reduction in caesarean sections (CSs) for fetal distress but not overall. Meconium below the vocal cords diagnosed by laryngoscopy was reduced, as was neonatal ventilation or neonatal intensive care unit admission, but there was no significant reduction in perinatal deaths or other morbidity. Planned sensitivity analysis excluding trials with greater risk of bias resulted in an absence of benefits for any of the outcomes studied.Settings with limited peripartum surveillance: two studies (855 women) were included. In the amnioinfusion group there was a reduction in CS for fetal distress and overall; meconium aspiration syndrome (RR 0.25, 95% CI 0.13 to 0.47), and neonatal ventilation or neonatal intensive care unit admission; and a trend towards reduced perinatal mortality (RR 0.37, 95% CI 0.13 to 1.01). In one of the studies, meconium below the vocal cords was reduced and, in the other, neonatal encephalopathy was reduced. Amnioinfusion is associated with substantive improvements in perinatal outcome only in settings where facilities for perinatal surveillance are limited. It is not clear whether the benefits are due to dilution of meconium or relief of oligohydramnios.In settings with standard peripartum surveillance, some non-substantive outcomes were improved in the initial analysis, but sensitivity analysis excluding trials with greater risk of bias eliminated these differences. Amnioinfusion is either ineffective in this setting, or its effects are masked by other strategies to optimise neonatal outcome.The trials reviewed are too small to address the possibility of rare but serious maternal adverse effects of amnioinfusion.

  7. Amnioinfusion for meconium-stained liquor in labour.

    PubMed

    Hofmeyr, G Justus; Xu, Hairong; Eke, Ahizechukwu C

    2014-01-23

    Amnioinfusion is thought to dilute meconium present in the amniotic fluid and so reduce the risk of meconium aspiration. To assess the effects of amnioinfusion for meconium-stained liquor on perinatal outcome. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (1 December 2013). Randomised trials comparing amnioinfusion with no amnioinfusion for women in labour with moderate or thick meconium staining of the amniotic fluid. Three review authors independently assessed eligibility and trial quality, and extracted data. Fourteen studies of variable quality (4435 women) are included.Subgroup analysis was performed for studies from settings with limited facilities to monitor the baby's condition during labour and intervene effectively, and settings with standard peripartum surveillance.Settings with standard peripartum surveillance: there was considerable heterogeneity for several outcomes. There was no significant reduction in the primary outcomes meconium aspiration syndrome, perinatal death or severe morbidity, and maternal death or severe morbidity. There was a reduction in caesarean sections (CSs) for fetal distress but not overall. Meconium below the vocal cords diagnosed by laryngoscopy was reduced, as was neonatal ventilation or neonatal intensive care unit admission, but there was no significant reduction in perinatal deaths or other morbidity. Planned sensitivity analysis excluding trials with greater risk of bias resulted in an absence of benefits for any of the outcomes studied.Settings with limited peripartum surveillance: three studies were included. In the amnioinfusion group there was a reduction in CS for fetal distress and overall; meconium aspiration syndrome (three studies, 1144 women; risk ratio (RR) 0.17, 95% confidence interval (CI) 0.05 to 0.52); perinatal mortality (three studies, 1151 women; RR 0.24, 95% CI 0.11 to 0.53) and neonatal ventilation or neonatal intensive care unit admission. In one of the studies, meconium below the vocal cords was reduced and, in the other, neonatal encephalopathy was reduced. Amnioinfusion is associated with substantive improvements in perinatal outcome only in settings where facilities for perinatal surveillance are limited. It is not clear whether the benefits are due to dilution of meconium or relief of oligohydramnios.In settings with standard peripartum surveillance, some non-substantive outcomes were improved in the initial analysis, but sensitivity analysis excluding trials with greater risk of bias eliminated these differences. Amnioinfusion is either ineffective in this setting, or its effects are masked by other strategies to optimise neonatal outcome.The trials reviewed are too small to address the possibility of rare but serious maternal adverse effects of amnioinfusion.

  8. Implications of the pH and temperature of diluted, cooled boar semen on fresh and frozen-thawed sperm motility characteristics.

    PubMed

    Purdy, P H; Tharp, N; Stewart, T; Spiller, S F; Blackburn, H D

    2010-10-15

    Boar semen is typically collected, diluted and cooled for AI use over numerous days, or frozen immediately after shipping to capable laboratories. The storage temperature and pH of the diluted, cooled boar semen could influence the fertility of boar sperm. Therefore, the purpose of this study was to determine the effects of pH and storage temperature on fresh and frozen-thawed boar sperm motility end points. Semen samples (n = 199) were collected, diluted, cooled and shipped overnight to the National Animal Germplasm Program laboratory for freezing and analysis from four boar stud facilities. The temperature, pH and motility characteristics, determined using computer automated semen analysis, were measured at arrival. Samples were then cryopreserved and post-thaw motility determined. The commercial stud was a significant source of variation for mean semen temperature and pH, as well as total and progressive motility, and numerous other sperm motility characteristics. Based on multiple regression analysis, pH was not a significant source of variation for fresh or frozen-thawed boar sperm motility end points. However, significant models were derived which demonstrated that storage temperature, boar, and the commercial stud influenced sperm motility end points and the potential success for surviving cryopreservation. We inferred that maintaining cooled boar semen at approximately 16 °C during storage will result in higher fresh and frozen-thawed boar sperm quality, which should result in greater fertility. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Heat capacity of the site-diluted spin dimer system Ba₃(Mn 1-xV x)₂O₈

    DOE PAGES

    Samulon, E. C.; Shapiro, M. C.; Fisher, I. R.

    2011-08-05

    Heat-capacity and susceptibility measurements have been performed on the diluted spin dimer compound Ba₃(Mn 1-xV x)₂O₈. The parent compound Ba₃Mn₂O₈ is a spin dimer system based on pairs of antiferromagnetically coupled S=1, 3d² Mn⁵⁺ ions such that the zero-field ground state is a product of singlets. Substitution of nonmagnetic S=0, 3d⁰ V⁵⁺ ions leads to an interacting network of unpaired Mn moments, the low-temperature properties of which are explored in the limit of small concentrations 0≤x≤0.05. The zero-field heat capacity of this diluted system reveals a progressive removal of magnetic entropy over an extended range of temperatures, with no evidencemore » for a phase transition. The concentration dependence does not conform to expectations for a spin-glass state. Rather, the data suggest a low-temperature random singlet phase, reflecting the hierarchy of exchange energies found in this system.« less

  10. Micromixer based on viscoelastic flow instability at low Reynolds number.

    PubMed

    Lam, Y C; Gan, H Y; Nguyen, N T; Lie, H

    2009-03-30

    We exploited the viscoelasticity of biocompatible dilute polymeric solutions, namely, dilute poly(ethylene oxide) solutions, to significantly enhance mixing in microfluidic devices at a very small Reynolds number, i.e., Re approximately 0.023, but large Peclet and elasticity numbers. With an abrupt contraction microgeometry (8:1 contraction ratio), two different dilute poly(ethylene oxide) solutions were successfully mixed with a short flow length at a relatively fast mixing time of <10 mus. Microparticle image velocimetry was employed in our investigations to characterize the flow fields. The increase in velocity fluctuation with an increase in flow rate and Deborah number indicates the increase in viscoelastic flow instability. Mixing efficiency was characterized by fluorescent concentration measurements. Our results showed that enhanced mixing can be achieved through viscoelastic flow instability under situations where molecular-diffusion and inertia effects are negligible. This approach bypasses the laminar flow limitation, usually associated with a low Reynolds number, which is not conducive to mixing.

  11. Micromixer based on viscoelastic flow instability at low Reynolds number

    PubMed Central

    Lam, Y. C.; Gan, H. Y.; Nguyen, N. T.; Lie, H.

    2009-01-01

    We exploited the viscoelasticity of biocompatible dilute polymeric solutions, namely, dilute poly(ethylene oxide) solutions, to significantly enhance mixing in microfluidic devices at a very small Reynolds number, i.e., Re≈0.023, but large Peclet and elasticity numbers. With an abrupt contraction microgeometry (8:1 contraction ratio), two different dilute poly(ethylene oxide) solutions were successfully mixed with a short flow length at a relatively fast mixing time of <10 μs. Microparticle image velocimetry was employed in our investigations to characterize the flow fields. The increase in velocity fluctuation with an increase in flow rate and Deborah number indicates the increase in viscoelastic flow instability. Mixing efficiency was characterized by fluorescent concentration measurements. Our results showed that enhanced mixing can be achieved through viscoelastic flow instability under situations where molecular-diffusion and inertia effects are negligible. This approach bypasses the laminar flow limitation, usually associated with a low Reynolds number, which is not conducive to mixing. PMID:19693399

  12. Rheological observation of glassy dynamics of dilute polymer solutions near the coil-stretch transition in elongational flows.

    PubMed

    Sridhar, T; Nguyen, D A; Prabhakar, R; Prakash, J Ravi

    2007-04-20

    It has long been conjectured that the macroscopic dynamics of dilute polymer solutions may exhibit a glasslike slowdown caused by ergodicity breaking, in the vicinity of the coil-stretch transition in elongational flows. We report experimental observations using a filament stretching rheometer that confirm the existence of such glassy states. It is observed that different time-dependent elongational strain-rate profiles lead to a pronounced history dependence and aging effects within a narrow range of strain rates. The results have a direct bearing on the analysis and design of processes employing dilute polymer solutions, such as ink-jet printing, surface coating, and turbulent-drag reduction.

  13. Transformation Model Choice in Nonlinear Regression Analysis of Fluorescence-based Serial Dilution Assays

    PubMed Central

    Fong, Youyi; Yu, Xuesong

    2016-01-01

    Many modern serial dilution assays are based on fluorescence intensity (FI) readouts. We study optimal transformation model choice for fitting five parameter logistic curves (5PL) to FI-based serial dilution assay data. We first develop a generalized least squares-pseudolikelihood type algorithm for fitting heteroscedastic logistic models. Next we show that the 5PL and log 5PL functions can approximate each other well. We then compare four 5PL models with different choices of log transformation and variance modeling through a Monte Carlo study and real data. Our findings are that the optimal choice depends on the intended use of the fitted curves. PMID:27642502

  14. Imaging with hypertelescopes: a simple modal approach

    NASA Astrophysics Data System (ADS)

    Aime, C.

    2008-05-01

    Aims: We give a simple analysis of imaging with hypertelescopes, a technique proposed by Labeyrie to produce snapshot images using arrays of telescopes. The approach is modal: we describe the transformations induced by the densification onto a sinusoidal decomposition of the focal image instead of the usual point spread function approach. Methods: We first express the image formed at the focus of a diluted array of apertures as the product R_0(α) X_F(α) of the diffraction pattern of the elementary apertures R_0(α) by the object-dependent interference term X_F(α) between all apertures. The interference term, which can be written in the form of a Fourier Series for an extremely diluted array, produces replications of the object, which makes observing the image difficult. We express the focal image after the densification using the approach of Tallon and Tallon-Bosc. Results: The result is very simple for an extremely diluted array. We show that the focal image in a periscopic densification of the array can be written as R_0(α) X_F(α/γ), where γ is the factor of densification. There is a dilatation of the interference term while the diffraction term is unchanged. After de-zooming, the image can be written as γ2 X_F(α)R_0(γ α), an expression which clearly indicates that the final image corresponds to the center of the Fizeau image intensified by γ2. The imaging limitations of hypertelescopes are therefore those of the original configuration. The effect of the suppression of image replications is illustrated in a numerical simulation for a fully redundant configuration and a non-redundant one.

  15. Rapid detection of aflatoxin B1 in medicinal materials of radix and rhizome by gold immunochromatographic assay.

    PubMed

    Hu, Shurong; Dou, Xiaowen; Zhang, Lei; Xie, Yanjun; Yang, Shihai; Yang, Meihua

    2018-05-22

    A rapid screening of the most toxic aflatoxin B 1 (AFB 1 ) in medicinal materials of radix and rhizome was performed by an immune chromatography method for the first time. The colloidal gold immunochromatographic strip was prepared after optimization of the conjugation of gold particles with monoclonal antibody, the test line and the control line. Under optimized conditions, the detection limit of the constructed test strip was as low as 0.1 ng mL -1 and the total analysis was conducted within 15 min by naked eyes. Four kinds of medicinal materials (Gastrodia elata, Poria cocos, Bletilla striata and Radix Angelicae Dahuricae) were investigated by the strip. Various complex matrixes pay a significant influence on the feasibility and effectiveness of the strip screening in medicinal materials. Aiming to the characteristics of selected medicinal materials, the screening was successfully proceeded with extraction by 70% methanol-water as well as three-fold dilution in Gastrodia elata and Radix Angelicae Dahuricae, 70% methanol-PBS as well as four-fold dilution in Poria cocos., and 60% methanol-water as well as four-fold dilution in Bletilla striata. Among the collected 40 samples, one was found to be positive of AFB 1 with level above 5 μg kg -1 . The result was in a good agreement with those obtained from LC-MS/MS determination (6.12 μg kg -1 ). The gold immunochromatographic strip was demonstrated as a rapid, cost-effective, reliable and on-site screening technique for mycotoxins in starch and polysaccharides-rich herbal medicines. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A workflow for multiclass determination of 256 pesticides in essential oils by liquid chromatography tandem mass spectrometry using evaporation and dilution approaches: Application to lavandin, lemon and cypress essential oils.

    PubMed

    Fillatre, Yoann; Rondeau, David; Daguin, Antoine; Communal, Pierre-Yves

    2016-01-01

    This paper describes the determination of 256 multiclass pesticides in cypress and lemon essential oils (EOs) by the way of liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) analysis using the scheduled selected reaction monitoring mode (sSRM) available on a hybrid quadrupole linear ion trap (QLIT) mass spectrometer. The performance of a sample preparation of lemon and cypress EOs based on dilution or evaporation under nitrogen assisted by a controlled heating were assessed. The best limits of quantification (LOQs) were achieved with the evaporation under nitrogen method giving LOQs≤10µgL(-1) for 91% of the pesticides. In addition the very satisfactory results obtained for recovery, repeatability and linearity showed that for EOs of relatively low evaporation temperature, a sample preparation based on evaporation under nitrogen is well adapted and preferable to dilution. By compiling these results with those previously published by some of us on lavandin EO, we proposed a workflow dedicated to multiresidue determination of pesticides in various EOs by LC-ESI/sSRM. Among the steps involved in this workflow, the protocol related to mass spectrometry proposes an alternative confirmation method to the classical SRM ratio criteria based on a sSRM survey scan followed by an information-dependent acquisition using the sensitive enhanced product ion (EPI) scan to generate MS/MS spectra then compared to a reference. The submitted workflow was applied to the case of lemon EOs samples highlighting for the first time the simultaneous detection of 20 multiclass pesticides in one EO. Some pesticides showed very high concentration levels with amounts greatly exceeding the mgL(-1). Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Validation of highly sensitive simultaneous targeted and untargeted analysis of keto-steroids by Girard P derivatization and stable isotope dilution-liquid chromatography-high resolution mass spectrometry.

    PubMed

    Frey, Alexander J; Wang, Qingqing; Busch, Christine; Feldman, Daniel; Bottalico, Lisa; Mesaros, Clementina A; Blair, Ian A; Vachani, Anil; Snyder, Nathaniel W

    2016-12-01

    A multiplexed quantitative method for the analysis of three major unconjugated steroids in human serum by stable isotope dilution liquid chromatography-high resolution mass spectrometry (LC-HRMS) was developed and validated on a Q Exactive Plus hybrid quadrupole/Orbitrap mass spectrometer. This quantification utilized isotope dilution and Girard P derivatization on the keto-groups of testosterone (T), androstenedione (AD) and dehydroepiandrosterone (DHEA) to improve ionization efficiency using electrospray ionization. Major isomeric compounds to T and DHEA; the inactive epimer of testosterone (epiT), and the metabolite of AD, 5α-androstanedione (5α-AD) were completely resolved on a biphenyl column within an 18min method. Inter- and intra-day method validation using LC-HRMS with qualifying product ions was performed and acceptable analytical performance was achieved. The method was further validated by comparing steroid levels from 100μL of serum from young vs older subjects. Since this approach provides high-dimensional HRMS data, untargeted analysis by age group was performed. DHEA and T were detected among the top analytes most significantly different across the two groups after untargeted LC-HRMS analysis, as well as a number of other still unknown metabolites, indicating the potential for combined targeted/untargeted analysis in steroid analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Analytical performance of benchtop total reflection X-ray fluorescence instrumentation for multielemental analysis of wine samples

    NASA Astrophysics Data System (ADS)

    Dalipi, Rogerta; Marguí, Eva; Borgese, Laura; Bilo, Fabjola; Depero, Laura E.

    2016-06-01

    Recent technological improvements have led to a widespread adoption of benchtop total reflection X-ray fluorescence systems (TXRF) for analysis of liquid samples. However, benchtop TXRF systems usually present limited sensitivity compared with high-scale instrumentation which can restrict its application in some fields. The aim of the present work was to evaluate and compare the analytical capabilities of two TXRF systems, equipped with low power Mo and W target X-ray tubes, for multielemental analysis of wine samples. Using the Mo-TXRF system, the detection limits for most elements were one order of magnitude lower than those attained using the W-TXRF system. For the detection of high Z elements like Cd and Ag, however, W-TXRF remains a very good option due to the possibility of K-Lines detection. Accuracy and precision of the obtained results have been evaluated analyzing spiked real wine samples and comparing the TXRF results with those obtained by inductively coupled plasma emission spectroscopy (ICP-OES). In general, good agreement was obtained between ICP-OES and TXRF results for the analysis of both red and white wine samples except for light elements (i.e., K) which TXRF concentrations were underestimated. However, a further achievement of analytical quality of TXRF results can be achieved if wine analysis is performed after dilution of the sample with de-ionized water.

  19. Chemical Warfare Agent Operational Exposure Hazard Assessment Research: FY07 Report and Analysis

    DTIC Science & Technology

    2010-07-01

    of the nerve agents sarin, soman, cyclohexylsarin, VX, and Russian VX in human urine using isotope-dilution gas chromatography-tandem mass...Needham L.L.; Barr, D.B. Quantitation of organophosphorous nerve agent metabolites in human urine using isotope dilution gas chromatography-tandem mass... nerve agents , VX, GB, or GF, and to determine lethal percutaneous (PC) levels of VX. Calibration of Physiologically-based pharmacokinetic biomarkers

  20. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    PubMed

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  1. Coating flow of an anti-HIV microbicide gel: boundary dilution and yield stress

    NASA Astrophysics Data System (ADS)

    Szeri, Andrew J.; Tasoglu, Savas; Park, Su Chan; Katz, David F.

    2010-11-01

    A recent study has confirmed, for the first time, that a vaginal gel formulation of the antiretroviral drug Tenofovir, when topically applied, significantly inhibits sexual HIV transmission to women [1]. However, the gel for this drug, and anti-HIV microbicide gels in general, have not been designed using an understanding of how gel spreading govern successful drug delivery. Elastohydrodynamic lubrication theory can be applied to model spreading of microbicide gels [2]. Here, we extend our initial analysis: we incorporate a yield stress, and we model the effects of gel dilution due to contact with vaginal fluid produced at the gel-tissue interface. Our model developed in [2] is supplemented with a convective-diffusive transport equation to characterize dilution, and solved using a multi-step scheme in a moving domain. The association between local dilution of gel and rheological properties is obtained experimentally. To model the common yield stress property of gels, we proceed by scaling analysis first. This establishes the conditions for validity of lubrication theory of a shear thinning yield stress fluid. This involves further development of the model in [2], incorporating a biviscosity model.[4pt] [1] Karim, et al., Science, 2010.[0pt] [2] Szeri, et al., Phy. of Fluids, 2008.

  2. Impact of pretreatment and downstream processing technologies on economics and energy in cellulosic ethanol production.

    PubMed

    Kumar, Deepak; Murthy, Ganti S

    2011-09-05

    While advantages of biofuel have been widely reported, studies also highlight the challenges in large scale production of biofuel. Cost of ethanol and process energy use in cellulosic ethanol plants are dependent on technologies used for conversion of feedstock. Process modeling can aid in identifying techno-economic bottlenecks in a production process. A comprehensive techno-economic analysis was performed for conversion of cellulosic feedstock to ethanol using some of the common pretreatment technologies: dilute acid, dilute alkali, hot water and steam explosion. Detailed process models incorporating feedstock handling, pretreatment, simultaneous saccharification and co-fermentation, ethanol recovery and downstream processing were developed using SuperPro Designer. Tall Fescue (Festuca arundinacea Schreb) was used as a model feedstock. Projected ethanol yields were 252.62, 255.80, 255.27 and 230.23 L/dry metric ton biomass for conversion process using dilute acid, dilute alkali, hot water and steam explosion pretreatment technologies respectively. Price of feedstock and cellulose enzymes were assumed as $50/metric ton and 0.517/kg broth (10% protein in broth, 600 FPU/g protein) respectively. Capital cost of ethanol plants processing 250,000 metric tons of feedstock/year was $1.92, $1.73, $1.72 and $1.70/L ethanol for process using dilute acid, dilute alkali, hot water and steam explosion pretreatment respectively. Ethanol production cost of $0.83, $0.88, $0.81 and $0.85/L ethanol was estimated for production process using dilute acid, dilute alkali, hot water and steam explosion pretreatment respectively. Water use in the production process using dilute acid, dilute alkali, hot water and steam explosion pretreatment was estimated 5.96, 6.07, 5.84 and 4.36 kg/L ethanol respectively. Ethanol price and energy use were highly dependent on process conditions used in the ethanol production plant. Potential for significant ethanol cost reductions exist in increasing pentose fermentation efficiency and reducing biomass and enzyme costs. The results demonstrated the importance of addressing the tradeoffs in capital costs, pretreatment and downstream processing technologies.

  3. Impact of pretreatment and downstream processing technologies on economics and energy in cellulosic ethanol production

    PubMed Central

    2011-01-01

    Background While advantages of biofuel have been widely reported, studies also highlight the challenges in large scale production of biofuel. Cost of ethanol and process energy use in cellulosic ethanol plants are dependent on technologies used for conversion of feedstock. Process modeling can aid in identifying techno-economic bottlenecks in a production process. A comprehensive techno-economic analysis was performed for conversion of cellulosic feedstock to ethanol using some of the common pretreatment technologies: dilute acid, dilute alkali, hot water and steam explosion. Detailed process models incorporating feedstock handling, pretreatment, simultaneous saccharification and co-fermentation, ethanol recovery and downstream processing were developed using SuperPro Designer. Tall Fescue (Festuca arundinacea Schreb) was used as a model feedstock. Results Projected ethanol yields were 252.62, 255.80, 255.27 and 230.23 L/dry metric ton biomass for conversion process using dilute acid, dilute alkali, hot water and steam explosion pretreatment technologies respectively. Price of feedstock and cellulose enzymes were assumed as $50/metric ton and 0.517/kg broth (10% protein in broth, 600 FPU/g protein) respectively. Capital cost of ethanol plants processing 250,000 metric tons of feedstock/year was $1.92, $1.73, $1.72 and $1.70/L ethanol for process using dilute acid, dilute alkali, hot water and steam explosion pretreatment respectively. Ethanol production cost of $0.83, $0.88, $0.81 and $0.85/L ethanol was estimated for production process using dilute acid, dilute alkali, hot water and steam explosion pretreatment respectively. Water use in the production process using dilute acid, dilute alkali, hot water and steam explosion pretreatment was estimated 5.96, 6.07, 5.84 and 4.36 kg/L ethanol respectively. Conclusions Ethanol price and energy use were highly dependent on process conditions used in the ethanol production plant. Potential for significant ethanol cost reductions exist in increasing pentose fermentation efficiency and reducing biomass and enzyme costs. The results demonstrated the importance of addressing the tradeoffs in capital costs, pretreatment and downstream processing technologies. PMID:21892958

  4. Effect of Coulomb friction on orientational correlation and velocity distribution functions in a sheared dilute granular gas.

    PubMed

    Gayen, Bishakhdatta; Alam, Meheboob

    2011-08-01

    From particle simulations of a sheared frictional granular gas, we show that the Coulomb friction can have dramatic effects on orientational correlation as well as on both the translational and angular velocity distribution functions even in the Boltzmann (dilute) limit. The dependence of orientational correlation on friction coefficient (μ) is found to be nonmonotonic, and the Coulomb friction plays a dual role of enhancing or diminishing the orientational correlation, depending on the value of the tangential restitution coefficient (which characterizes the roughness of particles). From the sticking limit (i.e., with no sliding contact) of rough particles, decreasing the Coulomb friction is found to reduce the density and spatial velocity correlations which, together with diminished orientational correlation for small enough μ, are responsible for the transition from non-gaussian to gaussian distribution functions in the double limit of small friction (μ→0) and nearly elastic particles (e→1). This double limit in fact corresponds to perfectly smooth particles, and hence the maxwellian (gaussian) is indeed a solution of the Boltzmann equation for a frictional granular gas in the limit of elastic collisions and zero Coulomb friction at any roughness. The high-velocity tails of both distribution functions seem to follow stretched exponentials even in the presence of Coulomb friction, and the related velocity exponents deviate strongly from a gaussian with increasing friction.

  5. Efficacy of Allium cepa test system for screening cytotoxicity and genotoxicity of industrial effluents originated from different industrial activities.

    PubMed

    Pathiratne, Asoka; Hemachandra, Chamini K; De Silva, Nimal

    2015-12-01

    Efficacy of Allium cepa test system for screening cytotoxicity and genotoxicity of treated effluents originated from four types of industrial activities (two textile industries, three rubber based industries, two common treatment plants of industrial zones, and two water treatment plants) was assessed. Physico-chemical parameters including the heavy metal/metalloid levels of the effluents varied depending on the industry profile, but most of the measured parameters in the effluents were within the specified tolerance limits of Sri Lankan environmental regulations for discharge of industrial effluents into inland surface waters. In the A. cepa test system, the undiluted effluents induced statistically significant root growth retardation, mitosis depression, and chromosomal aberrations in root meristematic cells in most cases in comparison to the dilution water and upstream water signifying effluent induced cytotoxicity and genotoxicity. Ethyl methane sulphonate (a mutagen, positive control) and all the effluents under 1:8 dilution significantly induced total chromosomal aberrations in root meristematic cells in comparison to the dilution water and upstream water indicating inadequacy of expected 1:8 dilutions in the receiving waters for curtailing genotoxic impacts. The results support the use of a practically feasible A. cepa test system for rapid screening of cytotoxicity and genotoxicity of diverse industrial effluents discharging into inland surface waters.

  6. Critical hematocrit and oxygen partial pressure in the beating heart of pigs.

    PubMed

    Hiebl, B; Mrowietz, C; Ploetze, K; Matschke, K; Jung, F

    2010-12-01

    In cardiac surgery the substitution of lost blood volume by plasma substitutes is a common therapeutical approach. None of the currently available blood substitutes has a sufficient oxygen transport capacity. This can limit the functional integrity of the myocardium known as highly oxygen consumptive. The study was aimed to get information about the minimal hematocrit, also known as critical hematocrit (cHct), which guarantees a stable and adequate oxygen partial pressure in the myocardium (pO2). In adult female pigs (n=7) the hematocrit was reduced by isovolemic blood dilution with an intravenous infusion of isotonic 4% gelatine polysuccinate solution, The substituted blood volume ranged between 3000ml and 7780ml (mean: 5254±1672ml). In all animals the pO2 of the myocardium of the beating heart and of the resting skeletal muscle increased until blood dilution resulted in a Hct decrease down to 15%. Further blood dilution resulted in a decrease of the pO2. Only after the Hct was <10% the pO2 was lower than before blood dilution and accompanied by a lethal ischemia of the myocardium. These data indicate a cHct of about 10% in the pig animal model. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Normalization of urinary drug concentrations with specific gravity and creatinine.

    PubMed

    Cone, Edward J; Caplan, Yale H; Moser, Frank; Robert, Tim; Shelby, Melinda K; Black, David L

    2009-01-01

    Excessive fluid intake can substantially dilute urinary drug concentrations and result in false-negative reports for drug users. Methods for correction ("normalization") of drug/metabolite concentrations in urine have been utilized by anti-doping laboratories, pain monitoring programs, and in environmental monitoring programs to compensate for excessive hydration, but such procedures have not been used routinely in workplace, legal, and treatment settings. We evaluated two drug normalization procedures based on specific gravity and creatinine. These corrections were applied to urine specimens collected from three distinct groups (pain patients, heroin users, and marijuana/ cocaine users). Each group was unique in characteristics, study design, and dosing conditions. The results of the two normalization procedures were highly correlated (r=0.94; range, 0.78-0.99). Increases in percent positives by specific gravity and creatinine normalization were small (0.3% and -1.0%, respectively) for heroin users (normally hydrated subjects), modest (4.2-9.8%) for pain patients (unknown hydration state), and substantial (2- to 38-fold increases) for marijuana/cocaine users (excessively hydrated subjects). Despite some limitations, these normalization procedures provide alternative means of dealing with highly dilute, dilute, and concentrated urine specimens. Drug/metabolite concentration normalization by these procedures is recommended for urine testing programs, especially as a means of coping with dilute specimens.

  8. Extractive biodegradation and bioavailability assessment of phenanthrene in the cloud point system by Sphingomonas polyaromaticivorans.

    PubMed

    Pan, Tao; Deng, Tao; Zeng, Xinying; Dong, Wei; Yu, Shuijing

    2016-01-01

    The biological treatment of polycyclic aromatic hydrocarbons is an important issue. Most microbes have limited practical applications because of the poor bioavailability of polycyclic aromatic hydrocarbons. In this study, the extractive biodegradation of phenanthrene by Sphingomonas polyaromaticivorans was conducted by introducing the cloud point system. The cloud point system is composed of a mixture of (40 g/L) Brij 30 and Tergitol TMN-3, which are nonionic surfactants, in equal proportions. After phenanthrene degradation, a higher wet cell weight and lower phenanthrene residue were obtained in the cloud point system than that in the control system. According to the results of high-performance liquid chromatography, the residual phenanthrene preferred to partition from the dilute phase into the coacervate phase. The concentration of residual phenanthrene in the dilute phase (below 0.001 mg/L) is lower than its solubility in water (1.18 mg/L) after extractive biodegradation. Therefore, dilute phase detoxification was achieved, thus indicating that the dilute phase could be discharged without causing phenanthrene pollution. Bioavailability was assessed by introducing the apparent logP in the cloud point system. Apparent logP decreased significantly, thus indicating that the bioavailability of phenanthrene increased remarkably in the system. This study provides a potential application of biological treatment in water and soil contaminated by phenanthrene.

  9. Osmotic Transport across Cell Membranes in Nondilute Solutions: A New Nondilute Solute Transport Equation

    PubMed Central

    Elmoazzen, Heidi Y.; Elliott, Janet A.W.; McGann, Locksley E.

    2009-01-01

    The fundamental physical mechanisms of water and solute transport across cell membranes have long been studied in the field of cell membrane biophysics. Cryobiology is a discipline that requires an understanding of osmotic transport across cell membranes under nondilute solution conditions, yet many of the currently-used transport formalisms make limiting dilute solution assumptions. While dilute solution assumptions are often appropriate under physiological conditions, they are rarely appropriate in cryobiology. The first objective of this article is to review commonly-used transport equations, and the explicit and implicit assumptions made when using the two-parameter and the Kedem-Katchalsky formalisms. The second objective of this article is to describe a set of transport equations that do not make the previous dilute solution or near-equilibrium assumptions. Specifically, a new nondilute solute transport equation is presented. Such nondilute equations are applicable to many fields including cryobiology where dilute solution conditions are not often met. An illustrative example is provided. Utilizing suitable transport equations that fit for two permeability coefficients, fits were as good as with the previous three-parameter model (which includes the reflection coefficient, σ). There is less unexpected concentration dependence with the nondilute transport equations, suggesting that some of the unexpected concentration dependence of permeability is due to the use of inappropriate transport equations. PMID:19348741

  10. Use of a series of chemostat cultures to isolate 'improved' variants of the Quorn mycoprotein fungus, Fusarium graminearum A3/5.

    PubMed

    Wiebe, M G; Robson, G D; Oliver, S G; Trinci, A P

    1994-11-01

    Variants (designated A23-S and A24-S) of the Quorn myco-protein fungus, Fusarium graminearum A3/5 were isolated from a series of glucose-limited cultures grown at a dilution rate of 0.18 h-1 for a combined total of 109 d. These variants had unchanged mycelial morphologies but, when grown in mixed culture with the parental strain (A3/5) in glucose-limited chemostat culture at 0.18 h-1, A23-S and A24-S had selection coefficients of 0.013 and 0.017 h-1, respectively, and supplanted A3/5. When a monoculture of A23-S was grown in a glucose-limited culture at a dilution rate of 0.18 h-1, the appearance of highly branched (so-called colonial) mutants was delayed compared with their appearance in chemostat cultures of the parental strain. Furthermore, when a monoculture of A24-S was grown in glucose-limited culture at 0.18 h-1, the appearance of colonial mutants was delayed even further. Thus, it is possible to isolate advantageous (relative to A3/5) variants of F. graminearum A3/5 which have unchanged mycelial morphologies, but in which the appearance of colonial mutants is delayed.

  11. Background correction in forensic photography. II. Photography of blood under conditions of non-uniform illumination or variable substrate color--practical aspects and limitations.

    PubMed

    Wagner, John H; Miskelly, Gordon M

    2003-05-01

    The combination of photographs taken at wavelengths at and bracketing the peak of a narrow absorbance band can lead to enhanced visualization of the substance causing the narrow absorbance band. This concept can be used to detect putative bloodstains by division of a linear photographic image taken at or near 415 nm with an image obtained by averaging linear photographs taken at or near 395 and 435 nm. Nonlinear images can also be background corrected by substituting subtraction for the division. This paper details experimental applications and limitations of this technique, including wavelength selection of the illuminant and at the camera. Characterization of a digital camera to be used in such a study is also detailed. Detection limits for blood using the three wavelength correction method under optimum conditions have been determined to be as low as 1 in 900 dilution, although on strongly patterned substrates blood diluted more than twenty-fold is difficult to detect. Use of only the 435 nm photograph to estimate the background in the 415 nm image lead to a twofold improvement in detection limit on unpatterned substrates compared with the three wavelength method with the particular camera and lighting system used, but it gave poorer background correction on patterned substrates.

  12. Effectiveness of a flow-based device using riboflavin photochemistry in damaging blood-borne viral nucleic acids.

    PubMed

    Zhu, Liguo; Tong, Hongli; Wang, Shufang; Yu, Yang; Liu, Zhong; Li, Changqing; Wang, Deqing

    2018-05-03

    Effectiveness of a flow-based treatment device using riboflavin photochemistry was demonstrated by cytopathic effect method using indicator viruses. However, inactivation efficacy against real blood-borne viruses needs to be evaluated, especially at nucleic acid level. Special plasma samples with varying concentrations of blood-borne virus were selected using a strict blood selection procedure and were treated with device treatment (DT). Nucleic acid test (NAT) using polymerase chain reaction fluorescence method was used to detect virus copies. The NAT value of 4325 in plasma with high Hepatitis B Virus (HBV) concentrations decreased to 1330 with DT. After 100-fold dilution, the NAT value was below the NAT detection limits with DT compared with 23.0 that without DT. The NAT value of 61.9 in plasma with medium HBV concentrations decreased to 37.8 with DT, and after 10-fold dilution, the NAT value was below the NAT detection limits with DT compared with below 20 that without DT. The Ct values of plasma with low concentrations of blood-borne viruses were below the NAT detection limits with DT. There was a dose effect with DT which was effective in blood-borne viruses damaging nucleic acids to a level below the NAT detection limits. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Determinations of dimethylsulphoniopropionate (DMSP) lyase activity using headspace analysis of dimethylsulphide (DMS)

    NASA Astrophysics Data System (ADS)

    Steinke, M.; Malin, G.; Turner, S. M.; Liss, P. S.

    2000-08-01

    The osmolyte dimethylsulphoniopropionate (DMSP) can be enzymatically cleaved to dimethylsulphide (DMS), acrylate and a proton. The enzyme involved in this reaction is dimethylpropiothetin dethiomethylase (DMSP lyase; enzyme classification number 4.4.1.3.). Although the importance of this reaction for the global sulphur cycle, the influence of DMS on atmospheric acidity and the possible effect on climate regulation have been widely recognised, our knowledge of DMSP lyases is limited to just a few studies. Activity measurements of DMSP lyases offer an important step towards a better understanding of the conditions under which DMS is produced. In the available published data somewhat similar methods have been used before, but a critical examination of the method limitations has not been reported. To encourage further research on this enzyme, we suggest and detail two protocols for measurements of DMSP lyase activity: An in vitro assay for crude cell extracts or purified enzyme and an in vivo method for whole cells, which we recently started to use. After addition of DMSP, samples incubated in a gas tight vial may produce DMS from enzymatic cleavage under suitable conditions, and a DMS production rate can be estimated from time-series measurements of DMS in the headspace of the vial. Headspace analysis of DMS is a useful and rapid technique to estimate and compare DMSP lyase activities from different sources. The relative rates of DMS production in the liquid and of the gas transfer between liquid and headspace, determine the rate of DMS production measured via headspace analysis. If DMS production in the liquid is higher than the rate of transfer, headspace measurements will not reflect the actual amount of DMS produced in the liquid. In this case, extracts have to be diluted to a level that ensures linearity between dilution factor and reduction of enzyme activity. Additionally, incubation volumes and vials should be selected to provide a high surface-to-volume ratio to ensure maximum flux of DMS from the aqueous phase into the headspace. The methods can be adapted to further investigate species- and strain-specific activities, biogeographical distribution, cellular location and biochemical properties of various DMSP lyases.

  14. The diversity-disease relationship: evidence for and criticisms of the dilution effect.

    PubMed

    Huang, Z Y X; VAN Langevelde, F; Estrada-Peña, A; Suzán, G; DE Boer, W F

    2016-08-01

    The dilution effect, that high host species diversity can reduce disease risk, has attracted much attention in the context of global biodiversity decline and increasing disease emergence. Recent studies have criticized the generality of the dilution effect and argued that it only occurs under certain circumstances. Nevertheless, evidence for the existence of a dilution effect was reported in about 80% of the studies that addressed the diversity-disease relationship, and a recent meta-analysis found that the dilution effect is widespread. We here review supporting and critical studies, point out the causes underlying the current disputes. The dilution is expected to be strong when the competent host species tend to remain when species diversity declines, characterized as a negative relationship between species' reservoir competence and local extinction risk. We here conclude that most studies support a negative competence-extinction relationship. We then synthesize the current knowledge on how the diversity-disease relationship can be modified by particular species in community, by the scales of analyses, and by the disease risk measures. We also highlight the complex role of habitat fragmentation in the diversity-disease relationship from epidemiological, evolutionary and ecological perspectives, and construct a synthetic framework integrating these three perspectives. We suggest that future studies should test the diversity-disease relationship across different scales and consider the multiple effects of landscape fragmentation.

  15. Assessment of Metronidazole Susceptibility in Helicobacter pylori: Statistical Validation and Error Rate Analysis of Breakpoints Determined by the Disk Diffusion Test

    PubMed Central

    Chaves, Sandra; Gadanho, Mário; Tenreiro, Rogério; Cabrita, José

    1999-01-01

    Metronidazole susceptibility of 100 Helicobacter pylori strains was assessed by determining the inhibition zone diameters by disk diffusion test and the MICs by agar dilution and PDM Epsilometer test (E test). Linear regression analysis was performed, allowing the definition of significant linear relations, and revealed correlations of disk diffusion results with both E-test and agar dilution results (r2 = 0.88 and 0.81, respectively). No significant differences (P = 0.84) were found between MICs defined by E test and those defined by agar dilution, taken as a standard. Reproducibility comparison between E-test and disk diffusion tests showed that they are equivalent and with good precision. Two interpretative susceptibility schemes (with or without an intermediate class) were compared by an interpretative error rate analysis method. The susceptibility classification scheme that included the intermediate category was retained, and breakpoints were assessed for diffusion assay with 5-μg metronidazole disks. Strains with inhibition zone diameters less than 16 mm were defined as resistant (MIC > 8 μg/ml), those with zone diameters equal to or greater than 16 mm but less than 21 mm were considered intermediate (4 μg/ml < MIC ≤ 8 μg/ml), and those with zone diameters of 21 mm or greater were regarded as susceptible (MIC ≤ 4 μg/ml). Error rate analysis applied to this classification scheme showed occurrence frequencies of 1% for major errors and 7% for minor errors, when the results were compared to those obtained by agar dilution. No very major errors were detected, suggesting that disk diffusion might be a good alternative for determining the metronidazole sensitivity of H. pylori strains. PMID:10203543

  16. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study*

    PubMed Central

    da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto

    2015-01-01

    Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746

  17. Structural features of dilute acid, steam exploded, and alkali pretreated mustard stalk and their impact on enzymatic hydrolysis.

    PubMed

    Kapoor, Manali; Raj, Tirath; Vijayaraj, M; Chopra, Anju; Gupta, Ravi P; Tuli, Deepak K; Kumar, Ravindra

    2015-06-25

    To overcome the recalcitrant nature of biomass several pretreatment methodologies have been explored to make it amenable to enzymatic hydrolysis. These methodologies alter cell wall structure primarily by removing/altering hemicelluloses and lignin. In this work, alkali, dilute acid, steam explosion pretreatment are systematically studied for mustard stalk. To assess the structural variability after pretreatment, chemical analysis, surface area, crystallinity index, accessibility of cellulose, FT-IR and thermal analysis are conducted. Although the extent of enzymatic hydrolysis varies upon the methodologies used, nevertheless, cellulose conversion increases from <10% to 81% after pretreatment. Glucose yield at 2 and 72h are well correlated with surface area and maximum adsorption capacity. However, no such relationship is observed for xylose yield. Mass balance of the process is also studied. Dilute acid pretreatment is the best methodology in terms of maximum sugar yield at lower enzyme loading. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Identification of the key odorants in Tahitian cured vanilla beans (Vanilla tahitensis) by GC-MS and an aroma extract dilution analysis.

    PubMed

    Takahashi, Makoto; Inai, Yoko; Miyazawa, Norio; Kurobayashi, Yoshiko; Fujita, Akira

    2013-01-01

    The key odorants of Tahitian vanilla beans (Vanilla tahitensis) were characterized by a sensory evaluation, aroma extract dilution analysis (AEDA), quantification, and aroma reconstitution. Vanillin and anisaldehyde were identified in the same highest flavor dilution (FD) factor as the most characteristic odor-active compounds in Tahitian vanilla beans, followed by anisyl alcohol and anisyl acetate. Vanillin and anisyl alcohol were by far the most abundant odorants present with the highest concentration in the beans, followed by acetic acid, anisaldehyde, and anisyl acetate. A sensory evaluation of Tahitian vanilla beans and its reconstitute aroma concentrate characterized both samples as similar. These results indicated vanillin, anisaldehyde, anisyl alcohol, and anisyl acetate to be the key odorants in Tahitian vanilla beans. 3-Methylnonane-2,4-dione were identified for the first time in vanilla beans. β-Damascenone and phenylacetic acid were identified for the first time in Tahitian vanilla beans.

  19. Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

    DOEpatents

    Chan, George C. Y. [Bloomington, IN; Hieftje, Gary M [Bloomington, IN

    2010-08-03

    A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

  20. Aqueous penetration and biological activity of moxifloxacin 0.5% ophthalmic solution and gatifloxacin 0.3% solution in cataract surgery patients.

    PubMed

    Kim, Dianne H; Stark, Walter J; O'Brien, Terrence P; Dick, James D

    2005-11-01

    To measure the achievable perioperative aqueous concentration of the commercially available topically administered fourth generation fluoroquinolones, moxifloxacin 0.5% ophthalmic solution, and gatifloxacin 0.3% ophthalmic solution, and to correlate this concentration with the agents' biological efficacy in the aqueous humor of patients undergoing routine cataract surgery. Prospective, randomized, parallel, double-masked, clinical trial. Fifty patients undergoing cataract extraction. Patients (n = 25) were given perioperative topical moxifloxacin 0.5% or topical gatifloxacin 0.3% (n = 25). One drop of antibiotic was administered every 10 minutes for 4 doses beginning 1 hour prior to surgery. Aqueous humor was sampled via paracentesis and antibiotic concentrations were determined using validated high performance liquid chromatography (HPLC) procedures. Dilution analyses were performed to determine the biological efficacy of the agents in the aqueous against Staphylococcus epidermidis, the most common cause of postcataract endophthalmitis. Aqueous humor antibiotic concentrations were measured using HPLC and microdilution bioassay techniques. Biological activity was measured as minimal inhibitory dilution and minimal bactericidal dilution. Aqueous humor concentrations for moxifloxacin via HPLC analysis were 1.80 (+/-1.21) microg/ml, whereas those for gatifloxacin were 0.48 (+/-0.34) microg/ml. This 3.8-fold difference in aqueous humor antibiotic concentrations was statistically significant (P = 0.00003). Similarly, the biological dilution analysis of the aqueous humor samples showed that moxifloxacin attained an estimated activity of 2.1 microg/ml, whereas the gatifloxacin activity was approximately 0.4 mug/ml, which represented a 4.9-fold difference. This study demonstrated that after topically administered perioperative antibiotics with cataract surgery, moxifloxacin 0.5% ophthalmic solution achieved a statistically significantly higher concentration in aqueous humor compared with gatifloxacin (P = 0.00003). Results from the broth dilution analysis showed that moxifloxacin 0.5% was biologically more active against S. epidermidis than gatifloxacin 0.3% in aqueous humor after topical application. There were no adverse events reported, and incision wounds healed quickly and as expected.

  1. Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomics

    PubMed Central

    2012-01-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) with stable isotope dilution (SID) is increasingly becoming a widely accepted assay for the quantification of proteins and peptides. These assays have shown great promise in relatively high throughput verification of candidate biomarkers. While the use of MRM-MS assays is well established in the small molecule realm, their introduction and use in proteomics is relatively recent. As such, statistical and computational methods for the analysis of MRM-MS data from proteins and peptides are still being developed. Based on our extensive experience with analyzing a wide range of SID-MRM-MS data, we set forth a methodology for analysis that encompasses significant aspects ranging from data quality assessment, assay characterization including calibration curves, limits of detection (LOD) and quantification (LOQ), and measurement of intra- and interlaboratory precision. We draw upon publicly available seminal datasets to illustrate our methods and algorithms. PMID:23176545

  2. Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomics.

    PubMed

    Mani, D R; Abbatiello, Susan E; Carr, Steven A

    2012-01-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) with stable isotope dilution (SID) is increasingly becoming a widely accepted assay for the quantification of proteins and peptides. These assays have shown great promise in relatively high throughput verification of candidate biomarkers. While the use of MRM-MS assays is well established in the small molecule realm, their introduction and use in proteomics is relatively recent. As such, statistical and computational methods for the analysis of MRM-MS data from proteins and peptides are still being developed. Based on our extensive experience with analyzing a wide range of SID-MRM-MS data, we set forth a methodology for analysis that encompasses significant aspects ranging from data quality assessment, assay characterization including calibration curves, limits of detection (LOD) and quantification (LOQ), and measurement of intra- and interlaboratory precision. We draw upon publicly available seminal datasets to illustrate our methods and algorithms.

  3. Quantitative determination of the hydrolysis products of nitrogen mustards in human urine by liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Lemire, Sharon W; Ashley, David L; Calafat, Antonia M

    2003-01-01

    Nitrogen mustards are a public health concern because of their extreme vesicant properties and the possible exposure of workers during the destruction of chemical stockpiles. A sensitive, rapid, accurate, and precise analysis for the quantitation of ultratrace levels of N-ethyldiethanolamine (EDEA) and N-methyldiethanolamine (MDEA) in human urine as a means of assessing recent exposure to the nitrogen mustards bis(2-chloroethyl)ethylamine and bis(2-chloroethyl)methylamine, respectively, was developed. The method was based on solid-phase extraction, followed by analysis of the urine extract using isotope-dilution high-performance liquid chromatography-mass spectrometry with TurbolonSpray ionization and multiple-reaction monitoring. The method limits of detection were 0.41 ng/mL for EDEA and 0.96 ng/mL for MDEA in 1 mL of urine with coefficients of variation < 10% for both compounds.

  4. Low-energy Model for Strongly Correlated Oxides

    NASA Astrophysics Data System (ADS)

    Liu, Shiu

    We provide a detailed derivation of the low-energy model for site-diluted strongly correlated oxides, an example being Zn-diluted La2CuO 4, in the limit of low doping together with a study of the ground-state properties of that model. The generally complicated Hamiltonian on the energy scale of the most relevant atomic orbitals is systematically downfolded to an effective model containing only spin-spin interactions using several techniques. In our study, beginning with the site-diluted three-band Hubbard model for La2ZnxCu(1- x)O4, we first determine the hybridized electronic states of CuO4 and ZnO4 plaquettes within the CuO2 planes utilizing Wannier-orthogonalization of oxygen orbitals and cell-perturbation of the Hamiltonian of each plaquett. Qualitatively, we find that the hybridization of zinc and oxygen orbitals can result in an impurity state with the energy epsilon, which is lower than the effective Hubbard gap U. Then we apply canonical transformation in the limit of the effective hopping integral t << epsilon, U, to obtain the low-energy, spin-only Hamiltonian, which includes terms of the order t2/U, t4/epsilon3, and t 4/Uepsilon2. In other words, besides the usual diluted nearest-neighbor superexchange J-terms of order t2/U, the low-energy model contains impurity-mediated, further-neighbor frustrating interactions among the Cu spins surrounding Zn-sites in an otherwise unfrustrated antiferromagnetic background. These terms, denoted as J'Zn and J''Zn , are of order t4/epsilon3 and can be substantial when epsilon ˜ U/2, the latter value corresponding to the realistic CuO2 parameters. The other further-neighbor Cu spin interactions are of order t 4/U3, which are neglected in both pure and diluted systems, because they are much lesser than J'Zn and J''Zn and independent of impurity concentration. In order to verify this spin-only model, we subsequently apply the T-matrix approach to study the effect of impurities on the antiferromagnetic order parameter. Previous theoretical T-matrix and quantum Monte Carlo (QMC) studies, which include only the dilution effect of impurities, show a large discrepancy with experimental neutron scattering and nuclear quadrupole resonance (NQR) data in the doping dependence of the staggered magnetization at low doping. We demonstrate that this discrepancy is eliminated by including zinc orbitals in the three-band Hubbard model and by including impurity-induced frustrations into the effective spin model with realistic CuO2 parameters. Recent experimental study shows a significantly stronger suppression of spin stiffness in the case of Zn-doped La2CuO4 compared to the Mg-doped case and thus gives a strong support to our theory. Different site-diluting dopants with different electron configurations affect the magnetism of the whole system differently. We argue that the available impurity orbitals are crucial in deriving theoretical models for the site-diluted systems and the proposed impurity-induced frustrations should be important in other strongly correlated oxides and charge-transfer insulators.

  5. Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

    NASA Technical Reports Server (NTRS)

    Meneghelli, Barry; Parrish, Clyde; Barile, Ron; Lueck, Dale E.

    1995-01-01

    A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

  6. Surface Plasmon Resonance imaging-based sensing for anti-bovine immunoglobulins detection in human milk and serum.

    PubMed

    Scarano, S; Scuffi, C; Mascini, M; Minunni, M

    2011-11-30

    Only few papers deal with Surface Plasmon Resonance imaging (SPRi) direct detection on complex matrices, limiting the biosensor application to real analytical problems. In this work a SPRi biosensor for anti-bovine IgG detection in untreated human bodily fluids, i.e. diluted human serum and milk, was developed. Enhanced levels of cow's milk antibodies in children's serum are suspected for their possible correlation with Type 1 diabetes during childhood and their detection in real samples was up to now performed by classical immunoassays based on indirect detection. The biosensor was optimised in standard samples and then in untreated human milk for anti-bovine IgG direct detection. The key novelty of the work is the evaluation of matrix effect by applying to real samples an experimental and ex ante method previously developed for SPRi signal sampling in standard solutions, called "Data Analyzer"; it punctually visualises and analyses the behaviour of receptor spots of the array, to select only spot areas with the best specific vs. unspecific signal values. In this way, benefits provide by SPRi image analysis are exploited here to quantify and minimise drawbacks due to the matrix effect, allowing to by-pass every matrix pre-treatment except dilution. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Pereira, Éderson R; de Almeida, Tarcísio S; Borges, Daniel L G; Carasek, Eduardo; Welz, Bernhard; Feldmann, Jörg; Campo Menoyo, Javier Del

    2016-04-01

    High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) has been applied for the development of a method for the determination of total As in fish oil samples using direct analysis. The method does not use any sample pretreatment, besides dilution with 1-propanole, in order to decrease the oil viscosity. The stability and sensitivity of As were evaluated using ruthenium and iridium as permanent chemical modifiers and palladium added in solution over the sample. The best results were obtained with ruthenium as the permanent modifier and palladium in solution added to samples and standard solutions. Under these conditions, aqueous standard solutions could be used for calibration for the fish oil samples diluted with 1-propanole. The pyrolysis and atomization temperatures were 1400 °C and 2300 °C, respectively, and the limit of detection and characteristic mass were 30 pg and 43 pg, respectively. Accuracy and precision of the method have been evaluated using microwave-assisted acid digestion of the samples with subsequent determination by HR-CS GF AAS and ICP-MS; the results were in agreement (95% confidence level) with those of the proposed method. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. DMSO Assisted Electrospray Ionization for the Detection of Small Peptide Hormones in Urine by Dilute-and-Shoot-Liquid-Chromatography-High Resolution Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Judák, Péter; Grainger, Janelle; Goebel, Catrin; Van Eenoo, Peter; Deventer, Koen

    2017-08-01

    The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed.

  9. Amoxicillin-resistant oral streptococci identified in dental plaque specimens from healthy Japanese adults.

    PubMed

    Masuda, Katsuhiko; Nemoto, Hirotoshi; Nakano, Kazuhiko; Naka, Shuhei; Nomura, Ryota; Ooshima, Takashi

    2012-05-01

    Infective endocarditis (IE) is known to be a life-threatening disease and invasive dental procedures are considered to be important factors. Oral amoxicillin (AMPC) is widely used for prophylaxis in patients with heart disorders who are at risk for IE. However, there is only limited information regarding the inhibition of oral bacteria by AMPC. Dental plaque specimens were obtained from 120 healthy Japanese adult subjects, then diluted and streaked onto selective medium for oral streptococci. The minimum inhibitory concentration (MIC) of AMPC was evaluated using a macro-dilution method by Clinical Laboratory Standard Institute (2006). Seven strains with an MIC of AMPC of 16μg/mL or more were isolated from 5 subjects. The bacterial species were confirmed by sequence analysis of 16S rRNA from each strain, which demonstrated that most were Streptococcus sanguinis, followed by Streptococcus oralis. Dental plaque specimens collected from these 5 subjects again after an interval of 2-3 months possessed no strains with an MIC of AMPC of 16μg/mL or more. These findings suggest that strains with a high MIC of AMPC are present in the oral cavities of Japanese adults, though they may be transient rather than inhabitants. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  10. Quantification of integrated HIV DNA by repetitive-sampling Alu-HIV PCR on the basis of poisson statistics.

    PubMed

    De Spiegelaere, Ward; Malatinkova, Eva; Lynch, Lindsay; Van Nieuwerburgh, Filip; Messiaen, Peter; O'Doherty, Una; Vandekerckhove, Linos

    2014-06-01

    Quantification of integrated proviral HIV DNA by repetitive-sampling Alu-HIV PCR is a candidate virological tool to monitor the HIV reservoir in patients. However, the experimental procedures and data analysis of the assay are complex and hinder its widespread use. Here, we provide an improved and simplified data analysis method by adopting binomial and Poisson statistics. A modified analysis method on the basis of Poisson statistics was used to analyze the binomial data of positive and negative reactions from a 42-replicate Alu-HIV PCR by use of dilutions of an integration standard and on samples of 57 HIV-infected patients. Results were compared with the quantitative output of the previously described Alu-HIV PCR method. Poisson-based quantification of the Alu-HIV PCR was linearly correlated with the standard dilution series, indicating that absolute quantification with the Poisson method is a valid alternative for data analysis of repetitive-sampling Alu-HIV PCR data. Quantitative outputs of patient samples assessed by the Poisson method correlated with the previously described Alu-HIV PCR analysis, indicating that this method is a valid alternative for quantifying integrated HIV DNA. Poisson-based analysis of the Alu-HIV PCR data enables absolute quantification without the need of a standard dilution curve. Implementation of the CI estimation permits improved qualitative analysis of the data and provides a statistical basis for the required minimal number of technical replicates. © 2014 The American Association for Clinical Chemistry.

  11. Dependence of matrix effect on ionization polarity during LC-ESI-MS analysis of derivatized amino acids in some natural samples.

    PubMed

    Oldekop, Maarja-Liisa; Rebane, Riin; Herodes, Koit

    2017-10-01

    Matrix effect, the influence of co-eluting components on the ionization efficiency of the analyte, affects the trueness and precision of the LC-ESI-MS analysis. Derivatization can reduce or eliminate matrix effect, for example, diethyl ethoxymethylenemalonate (DEEMM) derivatives have shown less matrix effect compared to other derivatives. Moreover, the use of negative ion mode can further reduce matrix effect. In order to investigate the combination of derivatization and different ionization modes, an LC-ESI-MS/MS method using alternating positive/negative ion mode was developed and validated. The analyses in positive and negative ion modes had comparable limit of quantitation values. The influence of ESI polarity on matrix effect was investigated during the analysis of 22 DEEMM-derivatized amino acids in herbal extracts and honeys. Sample dilution approach was used for the evaluation of the presence of matrix effect. Altogether, 4 honeys and 11 herbal extracts were analyzed, and the concentrations of 22 amino acids in the samples are presented. In the positive ion mode, matrix effect was observed for several amino acid derivatives and the matrix effect was stronger in honey samples compared to the herbal extracts. The negative ion mode was free from matrix effect, with only few exceptions in honeys (average relative standard deviation over all analytes and matrices was 8%; SD = 7%). The matrix effect was eliminated in the positive ion mode by sample dilution and agreement between concentrations from the two ion modes was achieved for most amino acids. In conclusion, it was shown that the combination of derivatization and negative ion mode can be a powerful tool for minimizing matrix effect in more complicated applications.

  12. Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique.

    PubMed

    Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji

    2010-11-15

    A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Cloning of Plasmodium falciparum by single-cell sorting.

    PubMed

    Miao, Jun; Li, Xiaolian; Cui, Liwang

    2010-10-01

    Malaria parasite cloning is traditionally carried out mainly by using the limiting dilution method, which is laborious, imprecise, and unable to distinguish multiply-infected RBCs. In this study, we used a parasite engineered to express green fluorescent protein (GFP) to evaluate a single-cell sorting method for rapidly cloning Plasmodium falciparum. By dividing a two-dimensional scattergram from a cell sorter into 17 gates, we determined the parameters for isolating singly-infected erythrocytes and sorted them into individual cultures. Pre-gating of the engineered parasites for GFP allowed the isolation of almost 100% GFP-positive clones. Compared with the limiting dilution method, the number of parasite clones obtained by single-cell sorting was much higher. Molecular analyses showed that parasite isolates obtained by single-cell sorting were highly homogenous. This highly efficient single-cell sorting method should prove very useful for cloning both P. falciparum laboratory populations from genetic manipulation experiments and clinical samples. Copyright 2010 Elsevier Inc. All rights reserved.

  14. [Isolation and identification of human periodontal ligament stem cells in vitro].

    PubMed

    Shen, Tao; Chang, Hui-jun; Jian, Cong-xiang; Yang, Yan-chun; Zhou, Ji-xiang

    2011-02-01

    To isolate and identify human periodontal ligament stem cells (PDLSC) by improved methods and assess the characteristics of PDLSC ex vivo. The periodontal ligament cells were obtained from the healthy impacted third molars and teeth extracted for orthodontic purposes and used to isolate PDLSC by limiting dilution assay. PDLSC were cultured and expanded in alpha-MEM supplemented with 10% FBS. Colony-forming assay, immunohistochemistry, flow cytometry, osteogenic and adipogenic induction were used to identify PDLSC. The obtained cells had high colony-forming efficiency and were positive staining for vimentin and negative for pancytokeratin. Flow cytometry revealed that the isolated cells were positive for STRO-1 and CD146 antibodies and most were in the G0/G1 phase of cell cycle. Under specific conditions, they could differentiate to the osteoblast and adipocyte lineages in vitro. Limiting dilution assay is an effective method to isolate PDLSC and the single-cell-derived colonies demonstrate the properties of stem cells in vitro.

  15. Nitromethane K-9 Detection Limit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strobel, R; Kury, J

    2003-08-29

    The Bureau of Alcohol, Tobacco and Firearms (ATF) trains canine/handler teams to detect explosives for government and other agencies worldwide. After completing the training program the teams are tested on an array containing explosives and numerous other samples designed to distract a canine. Passing this test results in a team's certification. These teams can be considered as ''detection instruments'' freshly calibrated just before leaving the ''factory''. Using these teams to examine special experimental arrays immediately following certification can lead to a better understanding of a canine's detection capabilities. Forty-one of these ''detection instruments'' were used in four test series withmore » arrays containing dilute nitromethane-in-water solutions. (The canines had been trained on the amount of nitromethane vapor in equilibrium with the undiluted liquid explosive.) By diluting liquid nitromethane with water, the amount of explosive vapor can be reduced many orders of magnitude to test the lower limit of the canine's nitromethane vapor detection response. The results are presented in this paper.« less

  16. The structures of interstitial hydrogen centers in VO 2 in the dilute limit from their vibrational properties and theory

    DOE PAGES

    Yin, W.; Qin, Ying; Fowler, W. B.; ...

    2016-07-28

    The introduction of a large concentration of H into VO 2 is known to suppress the insulating phase of the metal-insulator transition that occurs upon cooling below 340 K. We have used infrared spectroscopy and complementary theory to study the properties of interstitial H and D in VO 2 in the dilute limit to determine the vibrational frequencies, thermal stabilities, and equilibrium positions of isolated interstitial H and D centers. The vibrational lines of several OH and OD centers were observed to have thermal stabilities similar to that of the hydrogen that suppresses the insulating phase. Theory associates two ofmore » the four possible OH configurations for Hi in the insulating VO 2 monoclinic phase with OH lines seen by experiment. Furthermore, theory predicts the energies and vibrational frequencies for configurations with Hi trapped near a substitutional impurity and suggests such defects as candidates for additional OH centers that have been observed.« less

  17. Microfiltration: Effect of channel diameter on limiting flux and serum protein removal.

    PubMed

    Hurt, E E; Adams, M C; Barbano, D M

    2015-06-01

    Our objective was to determine the limiting flux and serum protein (SP) removal at 8, 9 and 10% true protein (TP) in the retentate recirculation loop using 0.1-µm ceramic graded permeability (GP) microfiltration (MF) membranes with 3mm channel diameters (CD). An additional objective was to compare the limiting flux and SP removal between 0.1-µm ceramic GP membranes with 3mm CD and previous research using 4-mm CD membranes. The MF system was operated at 50°C, using a diluted milk protein concentrate with 85% protein on a total solids basis (MPC85) as the MF feed. The limiting flux for the MF of diluted MPC85 was determined at 8, 9, and 10% TP concentration in the recirculation loop. The experiment using the 3-mm CD membranes was replicated 3 times for a total of 9 runs. On the morning of each run MPC85 was diluted with reverse osmosis water to a MF feed TP concentration of 5.4%. In all runs the starting flux was 55 kg/m2 per hour, the flux was then increased in steps until the limiting flux was reached. For the 3-mm CD membranes, the limiting flux was 128±0.3, 109±4, and 97±0.5 kg/m2 per hour at recirculation loop TP concentrations of 8.1±0.07, 9.2±0.04, and 10.2±0.03%, respectively. For the 3-mm CD membranes, increasing the flux from the starting to the limiting flux decreased the SP removal factor from 0.72±0.02 to 0.67±0.01; however, no difference in SP removal factor among the target recirculation loop TP concentrations was detected. The limiting flux at each recirculation loop target TP concentration was lower for the 3- compared with the 4-mm CD membranes. The differences in limiting fluxes between the 3- and 4-mm CD membranes were explained in part by the difference in cross-flow velocity (5.5±0.03 and 7.0±0.03 m/s for the 3- and 4-mm CD membranes, respectively). The SP removal factor was also lower for the 3- compared with the 4-mm CD membranes, indicating that more membrane fouling may have occurred in the 3- versus 4-mm CD membranes. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Organic aerosol evaporation and formation in biomass-burning plumes: The competition between dilution and chemistry

    NASA Astrophysics Data System (ADS)

    Pierce, J. R.; Kreidenweis, S. M.; Bian, Q.; Jathar, S.; Kodros, J.; Barsanti, K.; Hatch, L. E.; May, A.

    2017-12-01

    Secondary organic aerosol (SOA) has been shown to form in biomass-burning emissions in laboratory and field studies. However, there is significant variability among studies in mass enhancement, which could be due to differences in fuels, fire conditions, dilution, and/or limitations of laboratory experiments and observations. This study focuses on understanding processes affecting biomass-burning SOA formation in ambient plumes. The plume dilution rate impacts the organic partitioning between the gas and particle phases, which may impact the potential for SOA to form as well as the rate of SOA formation. We use an aerosol microphysics model that includes representations of volatility and oxidation chemistry to estimate SOA formation in the smoke emitted into the atmosphere. We add Gaussian dispersion to our aerosol microphysical model to estimate how SOA formation may vary under different ambient-plume conditions (e.g. fire size, emission mass flux, atmospheric stability). Smoke from small fires, such as typical prescribed burns, dilutes rapidly, which drives evaporation of organic vapor from the particle phase, leading to more effective SOA formation. Emissions from large fires, such as intense wildfires, dilute slowly, suppressing OA evaporation and subsequent SOA formation in the near field. We also demonstrate that different approaches to the calculation of OA enhancement in ambient plumes can lead to different conclusions regarding SOA formation. Normalized OA mass enhancement ratios of around 1 calculated using an inert tracer, such as black carbon or CO, have traditionally been interpreted as exhibiting little or no SOA formation; however, we show that SOA formation may have greatly contributed to the mass in these plumes.

  19. Determination of the alkylpyrazine composition of coffee using stable isotope dilution-gas chromatography-mass spectrometry (SIDA-GC-MS).

    PubMed

    Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke

    2013-07-03

    A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.

  20. Comprehensive Study of Volatile Compounds in Two Australian Rosé Wines: Aroma Extract Dilution Analysis (AEDA) of Extracts Prepared Using Solvent-Assisted Flavor Evaporation (SAFE) or Headspace Solid-Phase Extraction (HS-SPE).

    PubMed

    Wang, Jiaming; Gambetta, Joanna M; Jeffery, David W

    2016-05-18

    Two rosé wines, representing a tropical and a fruity/floral style, were chosen from a previous study for further exploration by aroma extract dilution analysis (AEDA) and quantitative analysis. Volatiles were extracted using either liquid-liquid extraction (LLE) followed by solvent-assisted flavor evaporation (SAFE) or a recently developed dynamic headspace (HS) sampling method utilizing solid-phase extraction (SPE) cartridges. AEDA was conducted using gas chromatography-mass spectrometry/olfactometry (GC-MS/O) and a total of 51 aroma compounds with a flavor dilution (FD) factor ≥3 were detected. Quantitative analysis of 92 volatiles was undertaken in both wines for calculation of odor activity values. The fruity and floral wine style was mostly driven by 2-phenylethanol, β-damascenone, and a range of esters, whereas 3-SHA and several volatile acids were seen as essential for the tropical style. When extraction methods were compared, HS-SPE was as efficient as SAFE for extracting most esters and higher alcohols, which were associated with fruity and floral characters, but it was difficult to capture volatiles with greater polarity or higher boiling point that may still be important to perceived wine aroma.

  1. Dilution and Mixing in transient velocity fields: a first-order analysis

    NASA Astrophysics Data System (ADS)

    Di Dato, Mariaines; de Barros, Felipe, P. J.; Fiori, Aldo; Bellin, Alberto

    2017-04-01

    An appealing remediation technique is in situ oxidation, which effectiveness is hampered by difficulties in obtaining good mixing of the injected oxidant with the contaminant, particularly when the contaminant plume is contained and therefore its deformation is physically constrained. Under such conditions (i.e. containment), mixing may be augmented by inducing temporal fluctuations of the velocity field. The temporal variability of the flow field may increase the deformation of the plume such that diffusive mass flux becomes more effective. A transient periodic velocity field can be obtained by an engineered sequence of injections and extractions from wells, which may serve also as a hydraulic barrier to confine the plume. Assessing the effectiveness of periodic flows to maximize solute mixing is a difficult task given the need to use a 3D setup and the large number of possible flow configurations that should be analyzed in order to identify the optimal one. This is the typical situation in which analytical solutions, though approximated, may assist modelers in screening possible alternative flow configurations such that solute dilution is maximized. To quantify dilution (i.e. a precondition that enables reactive mixing) we utilize the concept of the dilution index [1]. In this presentation, the periodic flow takes place in an aquifer with spatially variable hydraulic conductivity field which is modeled as a Stationary Spatial Random Function. We developed a novel first-order analytical solution of the dilution index under the hypothesis that the flow can be approximated as a sequence of steady state configurations with the mean velocity changing with time in intensity and direction. This is equivalent to assume that the characteristic time of the transient behavior is small compared to the period characterizing the change in time of the mean velocity. A few closed paths have been analyzed quantifying their effectiveness in enhancing dilution and thereby mixing between the resident contaminant and an oxidant. In particular, we considered three different flow configurations: (1) a "circular" pattern, in which the vector of the mean velocity rotates at a constant celerity; (2) a "shake" pattern, in which the velocity has a constant magnitude and changes direction alternatively leading to a "back and forth" type of movement and finally (3) a more general "shake and rotate" pattern, which combines the previous two configurations. The new analytical solution shows that dilution is affected by the configuration of the periodic mean flow. Results show that the dilution index increases when the rotation-shake configuration is adopted. In addition, the dilution index is augmented with the oscillation amplitude of the shake component. This analysis is useful to identify optimal flow configurations that may be approximately reproduced in the field and which efficiency may be checked more accurately by numerical simulations, thereby alleviating the computational burden by efficiently screening among alternative configurations. References [1] Kitanidis, P. K. (1994), The concept of the Dilution Index, Water Resour. Res., 30(7), 2011-2026, doi:10.1029/94WR00762.

  2. Performance analysis of a GPS Interferometric attitude determination system for a gravity gradient stabilized spacecraft. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Stoll, John C.

    1995-01-01

    The performance of an unaided attitude determination system based on GPS interferometry is examined using linear covariance analysis. The modelled system includes four GPS antennae onboard a gravity gradient stabilized spacecraft, specifically the Air Force's RADCAL satellite. The principal error sources are identified and modelled. The optimal system's sensitivities to these error sources are examined through an error budget and by varying system parameters. The effects of two satellite selection algorithms, Geometric and Attitude Dilution of Precision (GDOP and ADOP, respectively) are examined. The attitude performance of two optimal-suboptimal filters is also presented. Based on this analysis, the limiting factors in attitude accuracy are the knowledge of the relative antenna locations, the electrical path lengths from the antennae to the receiver, and the multipath environment. The performance of the system is found to be fairly insensitive to torque errors, orbital inclination, and the two satellite geometry figures-of-merit tested.

  3. Process and technoeconomic analysis of leading pretreatment technologies for lignocellulosic ethanol production using switchgrass.

    PubMed

    Tao, Ling; Aden, Andy; Elander, Richard T; Pallapolu, Venkata Ramesh; Lee, Y Y; Garlock, Rebecca J; Balan, Venkatesh; Dale, Bruce E; Kim, Youngmi; Mosier, Nathan S; Ladisch, Michael R; Falls, Matthew; Holtzapple, Mark T; Sierra, Rocio; Shi, Jian; Ebrik, Mirvat A; Redmond, Tim; Yang, Bin; Wyman, Charles E; Hames, Bonnie; Thomas, Steve; Warner, Ryan E

    2011-12-01

    Six biomass pretreatment processes to convert switchgrass to fermentable sugars and ultimately to cellulosic ethanol are compared on a consistent basis in this technoeconomic analysis. The six pretreatment processes are ammonia fiber expansion (AFEX), dilute acid (DA), lime, liquid hot water (LHW), soaking in aqueous ammonia (SAA), and sulfur dioxide-impregnated steam explosion (SO(2)). Each pretreatment process is modeled in the framework of an existing biochemical design model so that systematic variations of process-related changes are consistently captured. The pretreatment area process design and simulation are based on the research data generated within the Biomass Refining Consortium for Applied Fundamentals and Innovation (CAFI) 3 project. Overall ethanol production, total capital investment, and minimum ethanol selling price (MESP) are reported along with selected sensitivity analysis. The results show limited differentiation between the projected economic performances of the pretreatment options, except for processes that exhibit significantly lower monomer sugar and resulting ethanol yields. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Quantitative analysis of fungicide azoxystrobin in agricultural samples with rapid, simple and reliable monoclonal immunoassay.

    PubMed

    Watanabe, Eiki; Miyake, Shiro

    2013-01-15

    This work presents analytical performance of a kit-based direct competitive enzyme-linked immunosorbent assay (dc-ELISA) for azoxystrobin detection in agricultural products. The dc-ELISA was sufficiently sensitive for analysis of residue levels close to the maximum residue limits. The dc-ELISA did not show cross-reactivity to other strobilurin analogues. Absorbance decreased with the increase of methanol concentration in sample solution from 2% to 40%, while the standard curve became most linear when the sample solution contained 10% methanol. Agricultural samples were extracted with methanol, and the extracts were diluted with water to 10% methanol adequate. No significant matrix interference was observed. Satisfying recovery was found for all of spiked samples and the results were well agreed with the analysis with liquid chromatography. These results clearly indicate that the kit-based dc-ELISA is suitable for the rapid, simple, quantitative and reliable determination of the fungicide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Hollow Waveguide Gas Sensor for Mid-Infrared Trace Gas Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, S; Young, C; Chan, J

    2007-07-12

    A hollow waveguide mid-infrared gas sensor operating from 1000 cm{sup -1} to 4000 cm{sup -1} has been developed, optimized, and its performance characterized by combining a FT-IR spectrometer with Ag/Ag-halide hollow core optical fibers. The hollow core waveguide simultaneously serves as a light guide and miniature gas cell. CH{sub 4} was used as test analyte during exponential dilution experiments for accurate determination of the achievable limit of detection (LOD). It is shown that the optimized integration of an optical gas sensor module with FT-IR spectroscopy provides trace sensitivity at the few hundreds of parts-per-billion concentration range (ppb, v/v) for CH{submore » 4}.« less

  6. The application of decommissioned GEO satellites to CAPS

    NASA Astrophysics Data System (ADS)

    Fu, S. Y.; Wang, Z. R.; Shi, H. L.; Ma, L. H.

    2018-06-01

    To ensure the reliable service of geostationary earth orbiting (GEO) communication satellites during the period of in-orbit, the hardware design life of each system usually has some redundancies in contrast to the limited fuel used to keep the satellite position and attitude. After the brief analysis of the life of the satellite subsystems, the feasibility of turning the decommissioned GEO communication satellites into slightly inclined geosynchronous orbiting (SIGSO) satellites is proved. In addition, the role and the actual usage of SIGSO satellites in Chinese Area Positioning System (CAPS) are analysed and discussed, including the effect on the improvement of Position Dilution of Precision (PDOP) of the navigation constellation and the application to satellite communication system, thus the potential value of satellite material and devices is exploited.

  7. Construction and operation of a 10 cfm (cubic feet per minute) sampling system with a 10:1 dilution ratio for measuring condensable emissions. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steele, W.J.; Williamson, A.D.; McCain, J.D.

    1988-04-01

    The report describes a transportable sampling apparatus designed to sample incineration sources at municipal and hazardous-waste disposal facilities, and to provide non-contaminated samples of condensable materials. The sample gas, at a flow rate of 10 cubic feet per minute (c f/m), passes through a modified Source Assessment Sampling System (SASS) cyclone and is then diluted with clean air at 100 cf/m by a novel, perforated cone assembly. Rapid uniform dilution takes place through the vigorous mixing of the sample and clean air streams in the dilution chamber. The resultant gas, cooled to about atmospheric conditions, is passed through a mixingmore » section that provides a residence time of about 3 seconds. The resulting aerosol particles are collected on a Teflon-coated glass-fiber filter. These solids, along with those collected in the cyclone, are subsequently provided for chemical and biological assay analysis.« less

  8. Mixotrophic growth and biochemical analysis of Chlorella vulgaris cultivated with diluted monosodium glutamate wastewater.

    PubMed

    Ji, Yan; Hu, Wenrong; Li, Xiuqing; Ma, Guixia; Song, Mingming; Pei, Haiyan

    2014-01-01

    Monosodium glutamate wastewater (MSGW) is a potential medium for microbial cultivation because of containing abundant organic nutrient. This paper seeks to evaluate the feasibility of growing Chlorella vulgaris with MSGW and assess the influence of MSGW concentration on the biomass productivity and biochemical compositions. The MSGW diluted in different concentrations was prepared for microalga cultivation. C. vulgaris growth was greatly promoted with MSGW compared with the inorganic BG11 medium. C. vulgaris obtained the maximum biomass concentration (1.02 g/L) and biomass productivity (61.47 mg/Ld) with 100-time diluted MSGW. The harvested biomass was rich in protein (36.01-50.64%) and low in lipid (13.47-25.4%) and carbohydrate (8.94-20.1%). The protein nutritional quality and unsaturated fatty acids content of algal increased significantly with diluted MSGW. These results indicated that the MSGW is a feasible alternative for mass cultivation of C. vulgaris. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. [Simultaneous determination of four alkaloids in Corydalis decumbens (Thunb.) Pers. by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Shen, Yan; Han, Chao; Liu, Cuiping; Zhou, Yongfang; Xia, Biqi; Zhu, Zhenou; Liu, Aili

    2011-02-01

    A method for the analysis of 4 alkaloids in Corydalis decumbens (Thunb.) Pers. was developed by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-MS/MS). The sample was extracted in methanol by ultrasonic, filtered and diluted with methanol for further analysis. The analysis was performed on a C18 column (150 mm x 2.1 mm, 3.5 microm) using a gradient elution program with the mobile phase of 0.2% acetic acid solution and acetonitrile. The analyte was determined by an electrospray ionization tandem mass spectrometry in multiple reactions monitoring (MRM) mode. The qualitative and quantitative analyses were based on the retention times and characteristic ion pairs consisting of one parent ion and two fragment ions of the analyte. The limits of detection (LODs) for 4 alkaloids were in the range of 0.02 - 0.2 microg/L, and the limits of quantification (LOQs) were in the range of 0.07 - 0.66 microg/L. The average recoveries were in the range of 93.6% - 103.5% for 4 alkaloids with the relative standard deviations below 3.8%. This method is reliable, sensitive and reproducible, and it can be used for the quality control of Corydalis decumbens (Thunb.) Pers. sample.

  10. Detection of semi-volatile organic compounds in permeable ...

    EPA Pesticide Factsheets

    Abstract The Edison Environmental Center (EEC) has a research and demonstration permeable parking lot comprised of three different permeable systems: permeable asphalt, porous concrete and interlocking concrete permeable pavers. Water quality and quantity analysis has been ongoing since January, 2010. This paper describes a subset of the water quality analysis, analysis of semivolatile organic compounds (SVOCs) to determine if hydrocarbons were in water infiltrated through the permeable surfaces. SVOCs were analyzed in samples collected from 11 dates over a 3 year period, from 2/8/2010 to 4/1/2013.Results are broadly divided into three categories: 42 chemicals were never detected; 12 chemicals (11 chemical test) were detected at a rate of less than 10% or less; and 22 chemicals were detected at a frequency of 10% or greater (ranging from 10% to 66.5% detections). Fundamental and exploratory statistical analyses were performed on these latter analyses results by grouping results by surface type. The statistical analyses were limited due to low frequency of detections and dilutions of samples which impacted detection limits. The infiltrate data through three permeable surfaces were analyzed as non-parametric data by the Kaplan-Meier estimation method for fundamental statistics; there were some statistically observable difference in concentration between pavement types when using Tarone-Ware Comparison Hypothesis Test. Additionally Spearman Rank order non-parame

  11. A symmetrical method to obtain shear moduli from microrheology† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7sm02499a

    PubMed Central

    Nishi, Kengo

    2018-01-01

    Passive microrheology typically deduces shear elastic loss and storage moduli from displacement time series or mean-squared displacements (MSD) of thermally fluctuating probe particles in equilibrium materials. Common data analysis methods use either Kramers–Kronig (KK) transformation or functional fitting to calculate frequency-dependent loss and storage moduli. We propose a new analysis method for passive microrheology that avoids the limitations of both of these approaches. In this method, we determine both real and imaginary components of the complex, frequency-dependent response function χ(ω) = χ′(ω) + iχ′′(ω) as direct integral transforms of the MSD of thermal particle motion. This procedure significantly improves the high-frequency fidelity of χ(ω) relative to the use of KK transformation, which has been shown to lead to artifacts in χ′(ω). We test our method on both model and experimental data. Experiments were performed on solutions of worm-like micelles and dilute collagen solutions. While the present method agrees well with established KK-based methods at low frequencies, we demonstrate significant improvement at high frequencies using our symmetric analysis method, up to almost the fundamental Nyquist limit. PMID:29611576

  12. Assessing the Accuracy of the Tracer Dilution Method with Atmospheric Dispersion Modeling

    NASA Astrophysics Data System (ADS)

    Taylor, D.; Delkash, M.; Chow, F. K.; Imhoff, P. T.

    2015-12-01

    Landfill methane emissions are difficult to estimate due to limited observations and data uncertainty. The mobile tracer dilution method is a widely used and cost-effective approach for predicting landfill methane emissions. The method uses a tracer gas released on the surface of the landfill and measures the concentrations of both methane and the tracer gas downwind. Mobile measurements are conducted with a gas analyzer mounted on a vehicle to capture transects of both gas plumes. The idea behind the method is that if the measurements are performed far enough downwind, the methane plume from the large area source of the landfill and the tracer plume from a small number of point sources will be sufficiently well-mixed to behave similarly, and the ratio between the concentrations will be a good estimate of the ratio between the two emissions rates. The mobile tracer dilution method is sensitive to different factors of the setup such as placement of the tracer release locations and distance from the landfill to the downwind measurements, which have not been thoroughly examined. In this study, numerical modeling is used as an alternative to field measurements to study the sensitivity of the tracer dilution method and provide estimates of measurement accuracy. Using topography and wind conditions for an actual landfill, a landfill emissions rate is prescribed in the model and compared against the emissions rate predicted by application of the tracer dilution method. Two different methane emissions scenarios are simulated: homogeneous emissions over the entire surface of the landfill, and heterogeneous emissions with a hot spot containing 80% of the total emissions where the daily cover area is located. Numerical modeling of the tracer dilution method is a useful tool for evaluating the method without having the expense and labor commitment of multiple field campaigns. Factors tested include number of tracers, distance between tracers, distance from landfill to transect path, and location of tracers with respect to the hot spot. Results show that location of the tracers relative to the hot spot of highest landfill emissions makes the largest difference in accuracy of the tracer dilution method.

  13. Quantification of the degree of reaction of fly ash

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ben Haha, M., E-mail: mohsen.ben-haha@empa.c; De Weerdt, K., E-mail: klaartje.de.weerdt@sintef.n; Lothenbach, B.

    2010-11-15

    The quantification of the fly ash (FA) in FA blended cements is an important parameter to understand the effect of the fly ash on the hydration of OPC and on the microstructural development. The FA reaction in two different blended OPC-FA systems was studied using a selective dissolution technique based on EDTA/NaOH, diluted NaOH solution, the portlandite content and by backscattered electron image analysis. The amount of FA determined by selective dissolution using EDTA/NaOH is found to be associated with a significant possible error as different assumptions lead to large differences in the estimate of FA reacted. In addition, atmore » longer hydration times, the reaction of the FA is underestimated by this method due to the presence of non-dissolved hydrates and MgO rich particles. The dissolution of FA in diluted NaOH solution agreed during the first days well with the dissolution as observed by image analysis. At 28 days and longer, the formation of hydrates in the diluted solutions leads to an underestimation. Image analysis appears to give consistent results and to be most reliable technique studied.« less

  14. Rhenium-Oxygen Interactions at High Temperatures

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Myers, Dwight L.; Zhu, Dongming; Humphrey, Donald

    2000-01-01

    The reaction of pure rhenium metal with dilute oxygen/argon mixtures was studied from 600 to 1400 C. Temperature, oxygen pressure, and flow rates were systematically varied to determine the rate-controlling steps. At lower temperatures the oxygen/rhenium chemical reaction is rate limiting; at higher temperatures gas-phase diffusion of oxygen through the static boundary layer is rate limiting. At all temperatures post-reaction microstructures indicate preferential attack along certain crystallographic planes and defects.

  15. Single Particle-Inductively Coupled Plasma Mass Spectroscopy Analysis of Metallic Nanoparticles in Environmental Samples with Large Dissolved Analyte Fractions.

    PubMed

    Schwertfeger, D M; Velicogna, Jessica R; Jesmer, Alexander H; Scroggins, Richard P; Princz, Juliska I

    2016-10-18

    There is an increasing interest to use single particle-inductively coupled plasma mass spectroscopy (SP-ICPMS) to help quantify exposure to engineered nanoparticles, and their transformation products, released into the environment. Hindering the use of this analytical technique for environmental samples is the presence of high levels of dissolved analyte which impedes resolution of the particle signal from the dissolved. While sample dilution is often necessary to achieve the low analyte concentrations necessary for SP-ICPMS analysis, and to reduce the occurrence of matrix effects on the analyte signal, it is used here to also reduce the dissolved signal relative to the particulate, while maintaining a matrix chemistry that promotes particle stability. We propose a simple, systematic dilution series approach where by the first dilution is used to quantify the dissolved analyte, the second is used to optimize the particle signal, and the third is used as an analytical quality control. Using simple suspensions of well characterized Au and Ag nanoparticles spiked with the dissolved analyte form, as well as suspensions of complex environmental media (i.e., extracts from soils previously contaminated with engineered silver nanoparticles), we show how this dilution series technique improves resolution of the particle signal which in turn improves the accuracy of particle counts, quantification of particulate mass and determination of particle size. The technique proposed here is meant to offer a systematic and reproducible approach to the SP-ICPMS analysis of environmental samples and improve the quality and consistency of data generated from this relatively new analytical tool.

  16. Ecological risk assessment of on-site soil washing with iron(III) chloride in cadmium-contaminated paddy field.

    PubMed

    Nagai, Takashi; Horio, Takeshi; Yokoyama, Atsushi; Kamiya, Takashi; Takano, Hiroyuki; Makino, Tomoyuki

    2012-06-01

    On-site soil washing with iron(III) chloride reduces Cd levels in soil, and thus the human health risks caused by Cd in food. However, it may threaten aquatic organisms when soil washing effluent is discharged to open aquatic systems. Therefore, we conducted trial-scale on-site soil washing and ecological risk assessment in Nagano and Niigata prefectures, Japan. The ecological effect of effluent water was investigated by two methods. The first was bioassay using standard aquatic test organisms. Twice-diluted effluent water from the Nagano site and the original effluent water from the Niigata site had no significant effects on green algae, water flea, caddisfly, and fish. The safe dilution rates were estimated as 20 times and 10 times for the Nagano and Niigata sites, respectively, considering an assessment factor of 10. The second method was probabilistic effect analysis using chemical analysis and the species sensitivity distribution concept. The mixture effects of CaCl(2), Al, Zn, and Mn were considered by applying a response additive model. The safe dilution rates, assessed for a potentially affected fraction of species of 5%, were 7.1 times and 23.6 times for the Nagano and Niigata sites, respectively. The actual dilution rates of effluent water by river water at the Nagano and Niigata sites were 2200-67,000 times and 1300-110,000 times, respectively. These are much larger than the safe dilution rates derived from the two approaches. Consequently, the ecological risk to aquatic organisms of soil washing is evaluated as being below the concern level. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. The effects of host diversity on vector-borne disease: the conditions under which diversity will amplify or dilute the disease risk.

    PubMed

    Miller, Ezer; Huppert, Amit

    2013-01-01

    Multihost vector-borne infectious diseases form a significant fraction of the global infectious disease burden. In this study we explore the relationship between host diversity, vector behavior, and disease risk. To this end, we have developed a new dynamic model which includes two distinct host species and one vector species with variable preferences. With the aid of the model we were able to compute the basic reproductive rate, R 0, a well-established measure of disease risk that serves as a threshold parameter for disease outbreak. The model analysis reveals that the system has two different qualitative behaviors: (i) the well-known dilution effect, where the maximal R0 is obtained in a community which consists a single host (ii) a new amplification effect, denoted by us as diversity amplification, where the maximal R0 is attained in a community which consists both hosts. The model analysis extends on previous results by underlining the mechanism of both, diversity amplification and the dilution, and specifies the exact conditions for their occurrence. We have found that diversity amplification occurs where the vector prefers the host with the highest transmission ability, and dilution is obtained when the vector does not show any preference, or it prefers to bite the host with the lower transmission ability. The mechanisms of dilution and diversity amplification are able to account for the different and contradictory patterns often observed in nature (i.e., in some cases disease risk is increased while in other is decreased when the diversity is increased). Implication of the diversity amplification mechanism also challenges current premises about the interaction between biodiversity, climate change, and disease risk and calls for retrospective thinking in planning intervention policies aimed at protecting the preferred host species.

  18. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for a multiresidue analysis of pesticides in bovine milk.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-06-09

    A simple and rapid method based on solid-phase microextraction (SPME) technique followed by gas chromatography with microelectron-capture detection (GC-microECD) was developed for the simultaneous determination of more than 30 pesticides (pyrethroids and organochlorinated among others) in milk. To our knowledge, this is the first application of SPME for the determination of pyrethroid pesticides in milk. Negative matrix effects due to the complexity and lipophility of the studied matrix were reduced by diluting the sample with distilled water. A 2(5-1) fractional factorial design was performed to assess the influence of several factors (type of fiber coating, sampling mode, stirring, extraction temperature, and addition of sodium chloride) on the SPME procedure and to determine the optimal extraction conditions. After optimization of all the significant variables and interactions, the recommended procedure was established as follows: DSPME (using a polydimethylsiloxane (PDMS)/divinylbenzene (DVB) coating) of 1 mL of milk sample diluted with Milli-Q water (1:10 dilution ratio), at 100 degrees C, under stirring for 30 min. The proposed method showed good linearity and high sensitivity, with limits of detection (LOD) at the sub-ng mL(-1) level. Within a day and among days precisions were also evaluated (R.S.D.<15%). One of the most important attainments of this work was the use of external calibration with milk-matched standards to quantify the levels of the target analytes. The method was tested with liquid and powdered milk samples with different fat contents covering the whole commercial range. The efficiency of the extraction process was studied at several analyte concentration levels obtaining high recoveries (>80% in most cases) for different types of full-fat milks. The optimized procedure was validated with powdered milk certified reference material, which was quantified using external calibration and standard addition protocols. Finally, the DSPME-GC-microECD methodology was applied to the analysis of milk samples collected in farms of dairy cattle from NW Spain.

  19. Strong coupling effects in the polarized IR spectra of the chain hydrogen bond systems in imidazole crystals: H/D isotopic ?self-organization? effects in the IR spectra of isotopically diluted imidazole single crystals

    NASA Astrophysics Data System (ADS)

    Flakus, Henryk T.; Michta, Anna

    2004-11-01

    This paper presents the investigation results of the polarized IR spectra of H1245 imidazole crystals and of D1H245, D1245 and H1D245 imidazole deuterium derivative crystals. The spectra were measured using polarized light at the room temperature and at 77 K by a transmission method, for two different crystalline faces. Theoretical analysis of the results concerned linear dichroic effects, H/D isotopic and temperature effects, observed in the spectra of the hydrogen and of the deuterium bonds in imidazole crystals, at the frequency ranges of νN-H and νN-D bands. The basic crystal spectral properties can be satisfactorily interpreted in a quantitative way for a hydrogen bond linear dimer model. Such a model explains not only a two-branch structure of the νN-H and νN-D bands in crystalline spectra, but also some essential linear dichroic effects in the band frequency ranges, for isotopically diluted crystals. Model calculations, performed within the limits of the strong-coupling model, allowed for quantitative interpretation and for understanding of the basic properties of the hydrogen bond IR spectra of imidazole crystals, H/D isotopic, temperature and dichroic effects included. The results allowed verification of theoretical models proposed recently for the imidazole crystal spectra generation mechanisms. In the scope of our studies, the mechanism of H/D isotopic self-organization processes, taking place in the crystal hydrogen bond lattices, was also recognized. It was proved that for isotopically diluted crystalline samples of imidazole, a non-random distribution of protons and deuterons exclusively occurs in some restricted fragments (domains) of open chains of the hydrogen-bonded molecules. Nevertheless, these co-operative interactions between the hydrogen bonds do not concern adjacent fragments of neighboring hydrogen bond chains in the lattice. Analysis of the isotopic self-organization effects in the spectra of imidazole crystals delivered crucial arguments for understanding of the nature of the hydrogen bond spectra generation mechanisms.

  20. Enrichment and detection of microorganisms involved in direct and indirect methanogenesis from methanol in an anaerobic thermophilic bioreactor.

    PubMed

    Roest, Kees; Altinbas, Mahmut; Paulo, Paula L; Heilig, H G H J; Akkermans, Antoon D L; Smidt, Hauke; de Vos, Willem M; Stams, Alfons J M

    2005-10-01

    To gain insight into the microorganisms involved in direct and indirect methane formation from methanol in a laboratory-scale thermophilic (55 degrees C) methanogenic bioreactor, reactor sludge was disrupted and serial dilutions were incubated in specific growth media containing methanol and possible intermediates of methanol degradation as substrates. With methanol, growth was observed up to a dilution of 10(8). However, when Methanothermobacter thermoautotrophicus strain Z245 was added for H2 removal, growth was observed up to a 10(10)-fold dilution. With H2/CO2 and acetate, growth was observed up to dilutions of 10(9) and 10(4), respectively. Dominant microorganisms in the different dilutions were identified by 16S rRNA-gene diversity and sequence analysis. Furthermore, dilution polymerase chain reaction (PCR) revealed a similar relative abundance of Archaea and Bacteria in all investigated samples, except in enrichment with acetate, which contained 100 times less archaeal DNA than bacterial DNA. The most abundant bacteria in the culture with methanol and strain Z245 were most closely related to Moorella glycerini. Thermodesulfovibrio relatives were found with high sequence similarity in the H2/CO2 enrichment, but also in the original laboratory-scale bioreactor sludge. Methanothermobacter thermoautotrophicus strains were the most abundant hydrogenotrophic archaea in the H2/CO2 enrichment. The dominant methanol-utilizing methanogen, which was present in the 10(8)-dilution, was most closely related to Methanomethylovorans hollandica. Compared to direct methanogenesis, results of this study indicate that syntrophic, interspecies hydrogen transfer-dependent methanol conversion is equally important in the thermophilic bioreactor, confirming previous findings with labeled substrates and specific inhibitors.

  1. Development of a Pipeline for Exploratory Metabolic Profiling of Infant Urine

    PubMed Central

    Jackson, Frances; Georgakopoulou, Nancy; Kaluarachchi, Manuja; Kyriakides, Michael; Andreas, Nicholas; Przysiezna, Natalia; Hyde, Matthew J.; Modi, Neena; Nicholson, Jeremy K.; Wijeyesekera, Anisha; Holmes, Elaine

    2017-01-01

    Numerous metabolic profiling pipelines have been developed to characterize the composition of human biofluids and tissues, the vast majority of these being for studies in adults. To accommodate limited sample volume and to take into account the compositional differences between adult and infant biofluids, we developed and optimized sample handling and analytical procedures for studying urine from newborns. A robust pipeline for metabolic profiling using NMR spectroscopy was established, encompassing sample collection, preparation, spectroscopic measurement, and computational analysis. Longitudinal samples were collected from five infants from birth until 14 months of age. Methods of extraction and effects of freezing and sample dilution were assessed, and urinary contaminants from breakdown of polymers in a range of diapers and cotton wool balls were identified and compared, including propylene glycol, acrylic acid, and tert-butanol. Finally, assessment of urinary profiles obtained over the first few weeks of life revealed a dramatic change in composition, with concentrations of phenols, amino acids, and betaine altering systematically over the first few months of life. Therefore, neonatal samples require more stringent standardization of experimental design, sample handling, and analysis compared to that of adult samples to accommodate the variability and limited sample volume. PMID:27476583

  2. An isotope dilution gas chromatography/mass spectrometry method for trace analysis of xylene and its metabolites in tissues following threshold limit value exposures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyon, K.H.; Kracko, D.A.; Strunk, M.R.

    1995-12-01

    The existence of a nose-brain barrier that functions to protect the central nervous system (CNS) from inhaled toxicants has been postulated. Just as a blood-brain barrier protects the CNS from systemic toxicants, the nose-brain barrier may have similar characteristic functions. One component of interest is nasal xenobiotic metabolism and its effect on the transport of pollutants into the CNS at environmentally plausible levels of exposure. Previous results have shown that inhaled xylene are dimethyl phenol (DMP) and methyl benzyl alcohol (MBA), and the nonvolatile metabolites are toluic acid (TA) and methyl hippuric acid (MHA). The nonvolatile metabolites of xylene, alongmore » with a small quantity of volatiles, representing either parent xylene or volatile metabolites, are transported via the olfactory epithelium to the glomeruli within the olfactory bulbs of the brain. Further work will be done to establish the linearity for each analyte at the actual highest detection limit of the GC/MS.« less

  3. Nonlinear ionic transport through microstructured solid electrolytes: homogenization estimates

    NASA Astrophysics Data System (ADS)

    Curto Sillamoni, Ignacio J.; Idiart, Martín I.

    2016-10-01

    We consider the transport of multiple ionic species by diffusion and migration through microstructured solid electrolytes in the presence of strong electric fields. The assumed constitutive relations for the constituent phases follow from convex energy and dissipation potentials which guarantee thermodynamic consistency. The effective response is heuristically deduced from a multi-scale convergence analysis of the relevant field equations. The resulting homogenized response involves an effective dissipation potential per species. Each potential is mathematically akin to that of a standard nonlinear heterogeneous conductor. A ‘linear-comparison’ homogenization technique is then used to generate estimates for these nonlinear potentials in terms of available estimates for corresponding linear conductors. By way of example, use is made of the Maxwell-Garnett and effective-medium linear approximations to generate estimates for two-phase systems with power-law dissipation. Explicit formulas are given for some limiting cases. In the case of threshold-type behavior, the estimates exhibit non-analytical dilute limits and seem to be consistent with fields localized in low energy paths.

  4. Determination of artificial sweeteners in beverages with green mobile phases and high temperature liquid chromatography-tandem mass spectrometry.

    PubMed

    Ordoñez, Edgar Y; Rodil, Rosario; Quintana, José Benito; Cela, Rafael

    2015-02-15

    A new analytical procedure involving the use of water and a low percentage of ethanol combined to high temperature liquid chromatography-tandem mass spectrometry has been developed for the determination of nine high-intensity sweeteners in a variety of drink samples. The method permitted the analysis in 23min (including column reequilibration) and consuming only 0.85mL of a green organic solvent (ethanol). This methodology provided limits of detection (after 50-fold dilution) in the 0.05-10mg/L range, with recoveries (obtained from five different types of beverages) being in the 86-110% range and relative standard deviation values lower than 12%. Finally, the method was applied to 25 different samples purchased in Spain, where acesulfame and sucralose were the most frequently detected analytes (>50% of the samples) and cyclamate was found over the legislation limit set by the European Union in a sample and at the regulation boundary in three others. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Protein Structural Analysis via Mass Spectrometry-Based Proteomics

    PubMed Central

    Artigues, Antonio; Nadeau, Owen W.; Rimmer, Mary Ashley; Villar, Maria T.; Du, Xiuxia; Fenton, Aron W.; Carlson, Gerald M.

    2017-01-01

    Modern mass spectrometry (MS) technologies have provided a versatile platform that can be combined with a large number of techniques to analyze protein structure and dynamics. These techniques include the three detailed in this chapter: 1) hydrogen/deuterium exchange (HDX), 2) limited proteolysis, and 3) chemical crosslinking (CX). HDX relies on the change in mass of a protein upon its dilution into deuterated buffer, which results in varied deuterium content within its backbone amides. Structural information on surface exposed, flexible or disordered linker regions of proteins can be achieved through limited proteolysis, using a variety of proteases and only small extents of digestion. CX refers to the covalent coupling of distinct chemical species and has been used to analyze the structure, function and interactions of proteins by identifying crosslinking sites that are formed by small multi-functional reagents, termed crosslinkers. Each of these MS applications is capable of revealing structural information for proteins when used either with or without other typical high resolution techniques, including NMR and X-ray crystallography. PMID:27975228

  6. Computational Analysis of Intersubject Variability and Thrombin Generation in Dilutional Coagulopathy

    DTIC Science & Technology

    2012-11-01

    proteins: Factor (F)II, FV, FVII , FVIII, F IX, and FX, as well as the anticoagulants antithrombin (AT) and TF pathway inhibi- tor (TFPI). The results...coagulation factors FII, FV, FVII , FVIIa, FVIII, F IX and FX, as well as the anticoagulants TFPI and AT and the throm- bin generation inducer TF. The model...scenario and tissue factor concentration. CONCLUSION: Dilutional effects on thrombin genera- tion in a human population can be predicted from trends

  7. Rotor for processing liquids using movable capillary tubes

    DOEpatents

    Johnson, Wayne F.; Burtis, Carl A.; Walker, William A.

    1989-01-01

    A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.

  8. Rotor for processing liquids using movable capillary tubes

    DOEpatents

    Johnson, Wayne F [Loudon, TN; Burtis, Carl A [Oak Ridge, TN; Walker, William A [Knoxville, TN

    1989-05-30

    A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.

  9. Microwave-assisted extraction and quantitative LC/ID-MS measurement of total choline and free carnitine in food standard reference materials.

    PubMed

    Phillips, Melissa M; Sander, Lane C

    2012-01-01

    The Stakeholder Panel on Infant Formula and Adult Nutritionals of AOAC INTERNATIONAL has declared both choline and carnitine to be priority nutrients in infant formulas, and ongoing efforts exist to develop or improve Official Methods of Analysis for these nutrients. As a result, matrix-based certified reference materials are needed with assigned values for these compounds. In this work, traditional acid and enzymatic hydrolysis procedures were compared to microwave-assisted acid hydrolysis, and conditions optimized to provide complete sample hydrolysis and recovery of total choline from four food standard reference materials (SRMs): whole milk powder, whole egg powder, infant formula, and soy flour. The extracts were analyzed using LC on a mixed-mode column (simultaneous RP and ion exchange) with isotope dilution-MS detection to achieve simultaneous quantification of total choline and free carnitine. Total choline has been determined in these four food matrixes with excellent precision (0.65 to 2.60%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Free carnitine has been determined in two of these food matrixes with excellent precision (0.69 to 2.19%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Limitations in simultaneous determination of total choline and free carnitine resulted from extreme differences in concentration of the two components in egg powder and soy flour (at least three orders of magnitude). Samples required dilution to prevent poor LC peak shape, which caused decreased precision in the determination of low concentrations of free carnitine. Despite this limitation, the described method yields results comparable to current AOAC Official Method 999.14 Choline in Infant Formula, with a decrease of more than 2 h in sample preparation time.

  10. Rapid quantification of free cholesterol in tears using direct insertion/electron ionization-mass spectrometry.

    PubMed

    Wei, Xiaojia Eric; Korth, John; Brown, Simon H J; Mitchell, Todd W; Truscott, Roger J W; Blanksby, Stephen J; Willcox, Mark D P; Zhao, Zhenjun

    2013-12-09

    To establish a simple and rapid analytical method, based on direct insertion/electron ionization-mass spectrometry (DI/EI-MS), for measuring free cholesterol in tears from humans and rabbits. A stable-isotope dilution protocol employing DI/EI-MS in selected ion monitoring mode was developed and validated. It was used to quantify the free cholesterol content in human and rabbit tear extracts. Tears were collected from adult humans (n = 15) and rabbits (n = 10) and lipids extracted. Screening, full-scan (m/z 40-600) DI/EI-MS analysis of crude tear extracts showed that diagnostic ions located in the mass range m/z 350 to 400 were those derived from free cholesterol, with no contribution from cholesterol esters. DI/EI-MS data acquired using selected ion monitoring (SIM) were analyzed for the abundance ratios of diagnostic ions with their stable isotope-labeled analogues arising from the D6-cholesterol internal standard. Standard curves of good linearity were produced and an on-probe limit of detection of 3 ng (at 3:1 signal to noise) and limit of quantification of 8 ng (at 10:1 signal to noise). The concentration of free cholesterol in human tears was 15 ± 6 μg/g, which was higher than in rabbit tears (10 ± 5 μg/g). A stable-isotope dilution DI/EI-SIM method for free cholesterol quantification without prior chromatographic separation was established. Using this method demonstrated that humans have higher free cholesterol levels in their tears than rabbits. This is in agreement with previous reports. This paper provides a rapid and reliable method to measure free cholesterol in small-volume clinical samples.

  11. Hysteretic transitions in the Kuramoto model with inertia.

    PubMed

    Olmi, Simona; Navas, Adrian; Boccaletti, Stefano; Torcini, Alessandro

    2014-10-01

    We report finite-size numerical investigations and mean-field analysis of a Kuramoto model with inertia for fully coupled and diluted systems. In particular, we examine, for a gaussian distribution of the frequencies, the transition from incoherence to coherence for increasingly large system size and inertia. For sufficiently large inertia the transition is hysteretic, and within the hysteretic region clusters of locked oscillators of various sizes and different levels of synchronization coexist. A modification of the mean-field theory developed by Tanaka, Lichtenberg, and Oishi [Physica D 100, 279 (1997)] allows us to derive the synchronization curve associated to each of these clusters. We have also investigated numerically the limits of existence of the coherent and of the incoherent solutions. The minimal coupling required to observe the coherent state is largely independent of the system size, and it saturates to a constant value already for moderately large inertia values. The incoherent state is observable up to a critical coupling whose value saturates for large inertia and for finite system sizes, while in the thermodinamic limit this critical value diverges proportionally to the mass. By increasing the inertia the transition becomes more complex, and the synchronization occurs via the emergence of clusters of whirling oscillators. The presence of these groups of coherently drifting oscillators induces oscillations in the order parameter. We have shown that the transition remains hysteretic even for randomly diluted networks up to a level of connectivity corresponding to a few links per oscillator. Finally, an application to the Italian high-voltage power grid is reported, which reveals the emergence of quasiperiodic oscillations in the order parameter due to the simultaneous presence of many competing whirling clusters.

  12. Development and validation of procedures for assessment of competency of non-pharmacists in extemporaneous dispensing.

    PubMed

    Donnelly, Ryan F; McNally, Martin J; Barry, Johanne G

    2009-02-01

    To develop and validate procedures that may be suitable for assessment of competency of two groups of non-pharmacist staff (pharmacy students and trainee support staff) in extemporaneous dispensing. This is important given the prospect of remote supervision of community pharmacies in the UK. Analytical methods were validated according to International Conference on Harmonisation specifications and procedures were optimized to allow efficient drug extraction. This permitted straightforward determination of drug content in extemporaneously prepared lidocaine hydrochloride mouthwashes and norfloxacin creams and suspensions prepared by 10 participants recruited to represent the two groups of non-pharmacist staff. All 10 participants had completed the extemporaneous dispensing of all three products within 90 min. Extraction and analysis took approximately 15 min for each lidocaine hydrochloride mouthwash and 30 min for each diluted norfloxacin cream and norfloxacin suspension. The mean drug concentrations in lidocaine hydrochloride mouthwashes and diluted norfloxacin creams were within what are generally accepted as being pharmaceutically acceptable limits for drug content (100 +/- 5%) for both groups of participants. There was no significant difference in the mean drug concentration of norfloxacin suspensions prepared by the participant groups. However, it was notable that only one participant prepared a suspension containing a norfloxacin concentration that was within pharmaceutically acceptable limits (101.51%). A laboratory possessing suitable equipment and appropriately trained staff could cope readily with the large number of products prepared, for example, by a cohort of pre-registration students. Consequently, the validated procedures developed here could usefully be incorporated into the pre-registration examination for pharmacy students and a final qualifying examination for dispensers and pharmacy technicians. We believe that this is essential if the public and the profession are to have confidence in extemporaneous dispensing carried out in the absence of a pharmacist.

  13. Amnesic shellfish poisoning toxins in shellfish: estimation of uncertainty of measurement for a liquid chromatography/tandem mass spectrometry method.

    PubMed

    Holland, Patrick T; McNabb, Paul; Selwood, Andrew I; Neil, Tracey

    2003-01-01

    A liquid chromatography/mass spectrometry (LC/MS) method for amnesic shellfish poisoning toxins in shellfish was developed and validated. Tissue homogenate (4 g) was extracted with 16 mL methanol-water (1 + 1, v/v). Dilution into acetonitrile-water (1 + 9, v/v) was followed by C18 solid-phase extraction cleanup. Domoic acid (DA) and epi-domoic acid were determined by LC/MS/MS with electrospray ionization and multiple reaction monitoring. External calibration was performed with dilutions of a certified reference standard. Advantages of this method include speed, lower detection limits, and a very high degree of specificity. The LC/MS response was highly linear, and there were no significant interferences to the determination of DA. Formal method validation was performed on 4 shellfish species. Fortification studies gave recoveries (mean +/- SD; n = 24) of 93 +/- 14% at 1 mg/kg, and 93.3 +/- 7.6% at 20 mg/kg over all the species. Analysis of a mussel certified reference material showed the bias as < 5%. The limits of detection and quantitation were 0.15 and 0.5 mg/kg, respectively. Routine application of the method over 4 months gave a recovery for the QC sample (1 mg/kg fortified blank mussel homogenate) run with each batch of 88.9 +/- 5.5% (mean +/- SD; n = 37). The total uncertainty of measurement results were estimated as 0.12 (12%) at 0.25-5 mg/kg and 0.079 (7.9%) at 5-50 mg/kg. The major contribution to the uncertainty was the repeatability of the LC/MS determination, probably arising from subtle matrix effects.

  14. The optimal dose of dexmedetomidine added to an sufentanil-based analgesic regimen for postoperative pain control in spine surgery

    PubMed Central

    Dong, Chun-Shan; Lu, Yao; Zhang, Jun; Sun, Peng; Yu, Jun-Ma; Wu, Chao; Lu, Qiang

    2016-01-01

    Abstract Postoperative spinal patients remain a challenge for provision of postoperative analgesia. Patient-controlled intravenous analgesia (PCIA) is a major method in reducing the severe pain after the surgery in our institution, but some adverse effects prevent the use of adequate dosage opioids. This study was determined using the probit analysis to investigate the optimal dose of dexmedetomidine (DEX) infusion for postoperative analgesia combined with sufentanil (SUF) in spine surgery. The dose of DEX needed to produce satisfactory analgesia conditions following combination of 3.0 μg/kg SUF in PCIA pump, which was diluted to 250 mL with a 4 mL/h as background infusion. Patients were recruited with age 35 to 65 years. The satisfactory criteria of postoperative analgesia were determined with a average satisfaction level of pain control, sedation, self-satisfaction, and adverse effects, among others. The dose of DEX was determined using the modified Dixon's up-and-down method (0.5 μg/kg as a step size). The first patient was test at 3.0 μg/kg DEX. The patient was assessed at 6, 12, 36 hours, and termination of PCIA following the continuous infusion of DEX-SUF mixture in PCIA after surgery. Twenty-five patients were enrolled by predetermined criteria. The optimal dose of DEX required for satisfactory analgesic was 4.33 (SD, 0.38) μg/kg combined with 3.0 μg/kg SUF via a PCIA volume of 250 mL by background infusion of 4 mL/h. Using probit analysis, the ED50 of DEX was 4.12 μg/kg (95% confidence limits 3.74–4.52 μg/kg) for satisfactory postoperative analgesic in spine surgery, the ED95 of DEX was 4.85 μg/kg (95% confidence limits 4.48–7.13 μg/kg). There was no report of somnolence or respiratory depression, relevant bradycardia or hypotension, or over sedation in this study. The optimal dose of DEX was 4.33 (0.38) μg/kg−1 combined with 3.0 μg/kg−1 SUF diluted to 250 mL with a background infusion of 4 mL/h for satisfactory analgesic after spine surgery. From probit analysis, ED50 and ED95 of DEX were 4.12 μg/kg (95% confidence limits 3.74–4.52 μg/kg) and 4.85 μg.kg−1 (95% confidence limits 4.48–7.13 μg/kg), respectively. PMID:27684802

  15. Influence of dilution water composition on acute major ion toxicity to the mayfly Neocloeon triangulifer.

    EPA Science Inventory

    A number of field studies have shown that mayflies (Ephemeroptera) tend to be more sensitive than other benthic macroinvertebrates to elevated levels of total dissolved solids in streams. Until relatively recently, difficulties with culturing have limited the use of mayflies as ...

  16. 10 CFR 26.183 - Medical review officer.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... construed as a potential conflict of interest. Examples of relationships between laboratories and MROs that... licensee's or other entity's discretion, dilute test result. This action may include, but is not limited to... physiology of the donor. (2) The MRO may only consider the results of tests of specimens that are collected...

  17. 10 CFR 26.183 - Medical review officer.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... construed as a potential conflict of interest. Examples of relationships between laboratories and MROs that... licensee's or other entity's discretion, dilute test result. This action may include, but is not limited to... physiology of the donor. (2) The MRO may only consider the results of tests of specimens that are collected...

  18. 10 CFR 26.183 - Medical review officer.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... construed as a potential conflict of interest. Examples of relationships between laboratories and MROs that... licensee's or other entity's discretion, dilute test result. This action may include, but is not limited to... physiology of the donor. (2) The MRO may only consider the results of tests of specimens that are collected...

  19. Capillary Electrophoretic Technologies for Single Cell Metabolomics

    ERIC Educational Resources Information Center

    Lapainis, Theodore E.

    2009-01-01

    Understanding the functioning of the brain is hindered by a lack of knowledge of the full complement of neurotransmitters and neuromodulatory compounds. Single cell measurements aid in the discovery of neurotransmitters used by small subsets of neurons that would be diluted below detection limits or masked by ubiquitous compounds when working with…

  20. Accurate analysis of parabens in human urine using isotope-dilution ultrahigh-performance liquid chromatography-high resolution mass spectrometry.

    PubMed

    Zhou, Hui-Ting; Chen, Hsin-Chang; Ding, Wang-Hsien

    2018-02-20

    An analytical method that utilizes isotope-dilution ultrahigh-performance liquid chromatography coupled with hybrid quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS or called UHPLC-HRMS) was developed, and validated to be highly precise and accurate for the detection of nine parabens (methyl-, ethyl-, propyl-, isopropyl-, butyl-, isobutyl-, pentyl-, hexyl-, and benzyl-parabens) in human urine samples. After sample preparation by ultrasound-assisted emulsification microextraction (USAEME), the extract was directly injected into UHPLC-HRMS. By using negative electrospray ionization in the multiple reaction monitoring (MRM) mode and measuring the peak area ratios of both the natural and the labeled-analogues in the samples and calibration standards, the target analytes could be accurately identified and quantified. Another use for the labeled-analogues was to correct for systematic errors associated with the analysis, such as the matrix effect and other variations. The limits of quantitation (LOQs) were ranging from 0.3 to 0.6 ng/mL. High precisions for both repeatability and reproducibility were obtained ranging from 1 to 8%. High trueness (mean extraction recovery, or called accuracy) ranged from 93 to 107% on two concentration levels. According to preliminary results, the total concentrations of four most detected parabens (methyl-, ethyl-, propyl- and butyl-) ranged from 0.5 to 79.1 ng/mL in male urine samples, and from 17 to 237 ng/mL in female urine samples. Interestingly, two infrequently detected pentyl- and hexyl-parabens were found in one of the male samples in this study. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Optical gradients in a-Si:H thin films detected using real-time spectroscopic ellipsometry with virtual interface analysis

    NASA Astrophysics Data System (ADS)

    Junda, Maxwell M.; Karki Gautam, Laxmi; Collins, Robert W.; Podraza, Nikolas J.

    2018-04-01

    Virtual interface analysis (VIA) is applied to real time spectroscopic ellipsometry measurements taken during the growth of hydrogenated amorphous silicon (a-Si:H) thin films using various hydrogen dilutions of precursor gases and on different substrates during plasma enhanced chemical vapor deposition. A procedure is developed for optimizing VIA model configurations by adjusting sampling depth into the film and the analyzed spectral range such that model fits with the lowest possible error function are achieved. The optimal VIA configurations are found to be different depending on hydrogen dilution, substrate composition, and instantaneous film thickness. A depth profile in the optical properties of the films is then extracted that results from a variation in an optical absorption broadening parameter in a parametric a-Si:H model as a function of film thickness during deposition. Previously identified relationships are used linking this broadening parameter to the overall shape of the optical properties. This parameter is observed to converge after about 2000-3000 Å of accumulated thickness in all layers, implying that similar order in the a-Si:H network can be reached after sufficient thicknesses. In the early stages of growth, however, significant variations in broadening resulting from substrate- and processing-induced order are detected and tracked as a function of bulk layer thickness yielding an optical property depth profile in the final film. The best results are achieved with the simplest film-on-substrate structures while limitations are identified in cases where films have been deposited on more complex substrate structures.

  2. Pillar cuvettes: capillary-filled, microliter quartz cuvettes with microscale path lengths for optical spectroscopy.

    PubMed

    Holzner, Gregor; Kriel, Frederik Hermanus; Priest, Craig

    2015-05-05

    The goal of most analytical techniques is to reduce the lower limit of detection; however, it is sometimes necessary to do the opposite. High sample concentrations or samples with high molar absorptivity (e.g., dyes and metal complexes) often require multiple dilution steps or laborious sample preparation prior to spectroscopic analysis. Here, we demonstrate dilution-free, one-step UV-vis spectroscopic analysis of high concentrations of platinum(IV) hexachloride in a micropillar array, that is, "pillar cuvette". The cuvette is spontaneously filled by wicking of the liquid sample into the micropillar array. The pillar height (thus, the film thickness) defines the optical path length, which was reduced to between 10 and 20 μm in this study (3 orders of magnitude smaller than in a typical cuvette). Only one small droplet (∼2 μL) of sample is required, and the dispensed volume need not be precise or even known to the analyst for accurate spectroscopy measurements. For opaque pillars, we show that absorbance is linearly related to platinum concentration (the Beer-Lambert Law). For fully transparent or semitransparent pillars, the measured absorbance was successfully corrected for the fractional surface coverage of the pillars and the transmittance of the pillars and reference. Thus, both opaque and transparent pillars can be applied to absorbance spectroscopy of high absorptivity, microliter samples. It is also shown here that the pillar array has a useful secondary function as an integrated (in-cuvette) filter for particulates. For pillar cuvette measurements of platinum solutions spiked with 6 μm diameter polystyrene spheres, filtered and unfiltered samples gave identical spectra.

  3. Principles, performance, and applications of spectral reconstitution (SR) in quantitative analysis of oils by Fourier transform infrared spectroscopy (FT-IR).

    PubMed

    García-González, Diego L; Sedman, Jacqueline; van de Voort, Frederik R

    2013-04-01

    Spectral reconstitution (SR) is a dilution technique developed to facilitate the rapid, automated, and quantitative analysis of viscous oil samples by Fourier transform infrared spectroscopy (FT-IR). This technique involves determining the dilution factor through measurement of an absorption band of a suitable spectral marker added to the diluent, and then spectrally removing the diluent from the sample and multiplying the resulting spectrum to compensate for the effect of dilution on the band intensities. The facsimile spectrum of the neat oil thus obtained can then be qualitatively or quantitatively analyzed for the parameter(s) of interest. The quantitative performance of the SR technique was examined with two transition-metal carbonyl complexes as spectral markers, chromium hexacarbonyl and methylcyclopentadienyl manganese tricarbonyl. The estimation of the volume fraction (VF) of the diluent in a model system, consisting of canola oil diluted to various extents with odorless mineral spirits, served as the basis for assessment of these markers. The relationship between the VF estimates and the true volume fraction (VF(t)) was found to be strongly dependent on the dilution ratio and also depended, to a lesser extent, on the spectral resolution. These dependences are attributable to the effect of changes in matrix polarity on the bandwidth of the ν(CO) marker bands. Excellent VF(t) estimates were obtained by making a polarity correction devised with a variance-spectrum-delineated correction equation. In the absence of such a correction, SR was shown to introduce only a minor and constant bias, provided that polarity differences among all the diluted samples analyzed were minimal. This bias can be built into the calibration of a quantitative FT-IR analytical method by subjecting appropriate calibration standards to the same SR procedure as the samples to be analyzed. The primary purpose of the SR technique is to simplify preparation of diluted samples such that only approximate proportions need to be adhered to, rather than using exact weights or volumes, the marker accounting for minor variations. Additional applications discussed include the use of the SR technique in extraction-based, quantitative, automated FT-IR methods for the determination of moisture, acid number, and base number in lubricating oils, as well as of moisture content in edible oils.

  4. Sensitizing solid state nuclear magnetic resonance of dilute nuclei by spin-diffusion assisted polarization transfers.

    PubMed

    Lupulescu, Adonis; Frydman, Lucio

    2011-10-07

    Recent years have witnessed efforts geared at increasing the sensitivity of NMR experiments, by relying on the suitable tailoring and exploitation of relaxation phenomena. These efforts have included the use of paramagnetic agents, enhanced (1)H-(1)H incoherent and coherent transfers processes in 2D liquid state spectroscopy, and homonuclear (13)C-(13)C spin diffusion effects in labeled solids. The present study examines some of the opportunities that could open when exploiting spontaneous (1)H-(1)H spin-diffusion processes, to enhance relaxation and to improve the sensitivity of dilute nuclei in solid state NMR measurements. It is shown that polarization transfer experiments executed under sufficiently fast magic-angle-spinning conditions, enable a selective polarization of the dilute low-γ spins by their immediate neighboring protons. Repolarization of the latter can then occur during the time involved in monitoring the signal emitted by the low-γ nuclei. The basic features involved in the resulting approach, and its potential to improve the effective sensitivity of solid state NMR measurements on dilute nuclei, are analyzed. Experimental tests witness the advantages that could reside from utilizing this kind of approach over conventional cross-polarization processes. These measurements also highlight a number of limitations that will have to be overcome for transforming selective polarization transfers of this kind into analytical methods of choice. © 2011 American Institute of Physics

  5. Analysis of boron dilution in a four-loop PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, J.G.; Sha, W.T.

    1995-03-01

    Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four-loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plant ismore » at hot standby and the reactor coolant system has been heated to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated and a sensitivity study is performed to assess the accuracy of the numerical modeling of the geometry of the reactor coolant system.« less

  6. Performance analysis of an integrated GPS/inertial attitude determination system. M.S. Thesis - MIT

    NASA Technical Reports Server (NTRS)

    Sullivan, Wendy I.

    1994-01-01

    The performance of an integrated GPS/inertial attitude determination system is investigated using a linear covariance analysis. The principles of GPS interferometry are reviewed, and the major error sources of both interferometers and gyroscopes are discussed and modeled. A new figure of merit, attitude dilution of precision (ADOP), is defined for two possible GPS attitude determination methods, namely single difference and double difference interferometry. Based on this figure of merit, a satellite selection scheme is proposed. The performance of the integrated GPS/inertial attitude determination system is determined using a linear covariance analysis. Based on this analysis, it is concluded that the baseline errors (i.e., knowledge of the GPS interferometer baseline relative to the vehicle coordinate system) are the limiting factor in system performance. By reducing baseline errors, it should be possible to use lower quality gyroscopes without significantly reducing performance. For the cases considered, single difference interferometry is only marginally better than double difference interferometry. Finally, the performance of the system is found to be relatively insensitive to the satellite selection technique.

  7. A comparison study of Co and Cu doped MgO diluted magnetic thin films

    NASA Astrophysics Data System (ADS)

    Sarıtaş, S.; ćakıcı, T.; Muǧlu, G. Merhan; Kundakcı, M.; Yıldırım, M.

    2017-02-01

    Transition metal-doped MgO diluted magnetic thin films are appropriate candidates for spintronic applications and designing magnetic devices and sensors. Therefore, MgO:Co and MgO:Cu films were deposited on glass substrates by Chemical Spray Pyrolysis (CSP) method different thin film deposition parameters. Deposited different transition metal doped MgO thin films were compared in terms of optic and structural properties. Comparison optic analysis of the films was investigated spectral absorption and transmittance measurements by UV-Vis double beam spectrophotometer technique. Comparison structural analysis of the thin films was examined by using XRD, Raman Analysis, SEM, EDX and AFM techniques. The transition metal-doped; MgO:Co and MgO:Cu thin films maybe have potential applications in spintronics and magnetic data storage.

  8. Stability of piritramide in patient-controlled analgesia (PCA) solutions.

    PubMed

    Remane, D; Scriba, G; Meissner, W; Hartmann, M

    2009-06-01

    For patient controlled analgesia, syringes with solutions of 1.5 mg/ml piritramide in 0.9% aqueous sodium chloride are used. The physical and chemical stability for dilutions of the commercially available preparation of piritramide is limited up to 72 hours by the manufacturer. Since application duration for patient-controlled analgesia can exceed that limited time, stability was investigated by HPLC. Our results show that these solutions are chemically stable over a time period of 60 days.

  9. Host polymer influence on dilute polystyrene segmental dynamics

    NASA Astrophysics Data System (ADS)

    Lutz, T. R.

    2005-03-01

    We have utilized deuterium NMR to investigate the segmental dynamics of dilute (2%) d3-polystyrene (PS) chains in miscible polymer blends with polybutadiene, poly(vinyl ethylene), polyisoprene, poly(vinyl methylether) and poly(methyl methacrylate). In the dilute limit, we find qualitative differences depending upon whether the host polymer has dynamics that are faster or slower than that of pure PS. In blends where PS is the fast (low Tg) component, segmental dynamics are slowed upon blending and can be fit by the Lodge-McLeish model. When PS is the slow (high Tg) component, PS segmental dynamics speed up upon blending, but cannot be fit by the Lodge-McLeish model unless a temperature dependent self-concentration is employed. These results are qualitatively consistent with a recent suggestion by Kant, Kumar and Colby (Macromolecules, 2003, 10087), based upon data at higher concentrations. Furthermore, as the slow component, we find the segmental dynamics of PS has a temperature dependence similar to that of its host. This suggests viewing the high Tg component dynamics in a miscible blend as similar to a polymer in a low molecular weight solvent.

  10. Perpendicular diffusion of a dilute beam of charged particles in the PK-4 dusty plasma

    NASA Astrophysics Data System (ADS)

    Liu, Bin; Goree, John

    2015-09-01

    We study the random walk of a dilute beam of projectile dust particles that drift through a target dusty plasma. This random walk is a diffusion that occurs mainly due to Coulomb collisions with target particles that have a different size. In the direction parallel to the drift, projectiles exhibit mobility-limited motion with a constant average velocity. We use a 3D molecular dynamics (MD) simulation of the dust particle motion to determine the diffusion and mobility coefficients for the dilute beam. The dust particles are assumed to interact with a shielded Coulomb repulsion. They also experience gas drag. The beam particles are driven by a prescribed net force that is not applied to the target particles; in the experiments this net force is due to an imbalance of the electric and ion drag forces. This simulation is motivated by microgravity experiments, with the expectation that the scattering of projectiles studied here will be observed in upcoming PK-4 experiments on the International Space Station. Supported by NASA and DOE.

  11. Developing a modified preservative efficacy testing approach as a predictive tool for the evaluation of preservative systems in liquid home care products under variable test conditions.

    PubMed

    Hoyt, Anne L; Bushman, Don; Lewis, Nathan; Faber, Robert

    2012-01-01

    How can a formulator have confidence that a preservative system will perform as expected under adverse conditions? Extreme conditions that can lead to the development of "off odors" in the product can be a serious challenge for companies providing home care products in the global market. Formulation and stability testing occur under controlled parameters that simulate limited environmental conditions and microbial challenges are typically performed with a standard inoculum level. While this is an acceptable and dependable process, it does not necessarily assess how well a preservative system can perform under extreme environmental conditions or against unusually high levels of bacterial challenges. This is especially true when formulations are diluted and stored by the end-user. By modifying microbial challenge testing of a liquid dishwashing product to include unexpected dilution schemes, increased microbial assaults, and elevated temperatures, a pattern of preservative efficacy was established. The resulting approach proved to be a useful tool when developing use directions, recommended dilution levels, the overall surfactant system, preservative type, and storage restrictions.

  12. Characteristics of the Freshwater Cyanobacterium Microcystis aeruginosa Grown in Iron-Limited Continuous Culture

    PubMed Central

    Dang, T. C.; Fujii, M.; Rose, A. L.; Bligh, M.

    2012-01-01

    A continuous culturing system (chemostat) made of metal-free materials was successfully developed and used to maintain Fe-limited cultures of Microcystis aeruginosa PCC7806 at nanomolar iron (Fe) concentrations (20 to 50 nM total Fe). EDTA was used to maintain Fe in solution, with bioavailable Fe controlled by absorption of light by the ferric EDTA complex and resultant reduction of Fe(III) to Fe(II). A kinetic model describing Fe transformations and biological uptake was applied to determine the biologically available form of Fe (i.e., unchelated ferrous iron) that is produced by photoreductive dissociation of the ferric EDTA complex. Prediction by chemostat theory modified to account for the light-mediated formation of bioavailable Fe rather than total Fe was in good agreement with growth characteristics of M. aeruginosa under Fe limitation. The cellular Fe quota increased with increasing dilution rates in a manner consistent with the Droop theory. Short-term Fe uptake assays using cells maintained at steady state indicated that M. aeruginosa cells vary their maximum Fe uptake rate (ρmax) depending on the degree of Fe stress. The rate of Fe uptake was lower for cells grown under conditions of lower Fe availability (i.e., lower dilution rate), suggesting that cells in the continuous cultures adjusted to Fe limitation by decreasing ρmax while maintaining a constant affinity for Fe. PMID:22210212

  13. Shear Strength of Stabilized Kaolin Soil Using Liquid Polymer

    NASA Astrophysics Data System (ADS)

    Azhar, A. T. S.; Fazlina, M. I. S.; Nizam, Z. M.; Fairus, Y. M.; Hakimi, M. N. A.; Riduan, Y.; Faizal, P.

    2017-08-01

    The purpose of this research is to investigate the suitability of polymer in soil stabilization by examining its strength to withstand compressive strength. Throughout this research study, manufactured polymer was used as a chemical liquid soil stabilizer. The liquid polymer was diluted using a proposed dilution factor of 1 : 3 (1 part polymer: 3 parts distilled water) to preserve the workability of the polymer in kaolin mixture. A mold with a diameter of 50 mm and a height of 100 mm was prepared. Kaolin soil was mixed with different percentages of polymer from 10%, 15%, 20%, 25%, 30% and 35% of the mass of the kaolin clay sample. Kaolin mixtures were tested after a curing period of 3 days, 7 days, 14 days and 28 days respectively. The physical properties were determined by conducting a moisture content test and Atterberg limit test which comprise of liquid limit, plastic limit and shrinkage limit. Meanwhile, the mechanical properties of the soil shear strength were identified through an unconfined compressive strength (UCS) test. Stabilized kaolin soil showed the highest compressive strength value when it was mixed with 35% of polymer compared to other percentages that marked an increment in strength which are 45.72% (3 days), 67.57% (7 days), 81.73% (14 days) and 77.84% (28 days). Hence, the most effective percentage of liquid polymer which should be used to increase the strength of kaolin soil is 35%.

  14. Globule-size distribution in injectable 20% lipid emulsions: Compliance with USP requirements.

    PubMed

    Driscoll, David F

    2007-10-01

    The compliance of injectable 20% lipid emulsions with the globule-size limits in chapter 729 of the U.S. Pharmacopeia (USP) was examined. As established in chapter 729, dynamic light scattering was applied to determine mean droplet diameter (MDD), with an upper limit of 500 nm. Light obscuration was used to determine the size of fat globules found in the large-diameter tail, expressed as the volume-weighted percent fat exceeding 5 microm (PFAT(5)), with an upper limit of 0.05%. Compliance of seven different emulsions, six of which were stored in plastic bags, with USP limits was assessed. To avoid reaching coincidence limits during the application of method II from overly concentrated emulsion samples, a variable dilution scheme was used to optimize the globule-size measurements for each emulsion. One-way analysis of variance of globule-size distribution (GSD) data was conducted if any results of method I or II exceeded the respective upper limits. Most injectable lipid emulsions complied with limits established by USP chapter 729, with the exception of those of one manufacturer, which failed limits as proposed for to meet the PFAT(5) three of the emulsions tested. In contrast, all others studied (one packaged in glass and three packaged in plastic) met both criteria. Among seven injectable lipid emulsions tested for GSD, all met USP chapter 729 MDD requirements and three, all from the same manufacturer and packaged in plastic, did not meet PFAT(5) requirements.

  15. Post-harvest processing methods for reduction of silica and alkali metals in wheat straw.

    PubMed

    Thompson, David N; Shaw, Peter G; Lacey, Jeffrey A

    2003-01-01

    Silica and alkali metals in wheat straw limit its use for bioenergy and gasification. Slag deposits occur via the eutectic melting of SiO2 with K2O, trapping chlorides at surfaces and causing corrosion. A minimum melting point of 950 degrees C is desirable, corresponding to an SiO2:K2O weight ratio of about 3:1. Mild chemical treatments were used to reduce Si, K, and Cl, while varying temperature, concentration, % solids, and time. Dilute acid was more effective at removing K and Cl, while dilute alkali was more effective for Si. Reduction of minerals in this manner may prove economical for increasing utilization of the straw for combustion or gasification.

  16. In vitro replication highlights the mutability of prions.

    PubMed

    Vanni, Ilaria; Di Bari, Michele Angelo; Pirisinu, Laura; D'Agostino, Claudia; Agrimi, Umberto; Nonno, Romolo

    2014-01-01

    Prions exist as strains, which are thought to reflect PrP(Sc) conformational variants. Prion strains can mutate and it has been proposed that prion mutability depends on an intrinsic heterogeneity of prion populations that would behave as quasispecies. We investigated in vitro prion mutability of 2 strains, by following PrP(Sc) variations of populations serially propagated in PMCA under constant environmental pressure. Each strain was propagated either at low dilution of the seed, i.e., by large population passages, or at limiting dilution, mimicking bottleneck events. In both strains, PrP(Sc) conformational variants were identified only after large population passages, while repeated bottleneck events caused a rapid decline in amplification rates. These findings support the view that mutability is an intrinsic property of prions.

  17. An accurate algorithm for the detection of DNA fragments from dilution pool sequencing experiments.

    PubMed

    Bansal, Vikas

    2018-01-01

    The short read lengths of current high-throughput sequencing technologies limit the ability to recover long-range haplotype information. Dilution pool methods for preparing DNA sequencing libraries from high molecular weight DNA fragments enable the recovery of long DNA fragments from short sequence reads. These approaches require computational methods for identifying the DNA fragments using aligned sequence reads and assembling the fragments into long haplotypes. Although a number of computational methods have been developed for haplotype assembly, the problem of identifying DNA fragments from dilution pool sequence data has not received much attention. We formulate the problem of detecting DNA fragments from dilution pool sequencing experiments as a genome segmentation problem and develop an algorithm that uses dynamic programming to optimize a likelihood function derived from a generative model for the sequence reads. This algorithm uses an iterative approach to automatically infer the mean background read depth and the number of fragments in each pool. Using simulated data, we demonstrate that our method, FragmentCut, has 25-30% greater sensitivity compared with an HMM based method for fragment detection and can also detect overlapping fragments. On a whole-genome human fosmid pool dataset, the haplotypes assembled using the fragments identified by FragmentCut had greater N50 length, 16.2% lower switch error rate and 35.8% lower mismatch error rate compared with two existing methods. We further demonstrate the greater accuracy of our method using two additional dilution pool datasets. FragmentCut is available from https://bansal-lab.github.io/software/FragmentCut. vibansal@ucsd.edu. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  18. Nature and Analysis of Chemical Species.

    ERIC Educational Resources Information Center

    Shuman, Mark S.; Fogleman, Wavell W.

    1978-01-01

    Presents a literature review of the nature and analysis of chemical species in water, covering publications of 1976-77. This review is concerned with inorganics, and it covers: (1) electrochemical analysis; (2) spectroscopy; (3) neutron activation, radiochemical analysis, and isotope dilution. A list of 262 references is also presented. (HM)

  19. Formulation of Water Quality Models for Streams, Lakes and Reservoirs: Modeler’s Perspective

    DTIC Science & Technology

    1989-07-01

    dilution of efflu- ent plumes . These mixing models also address the question of whether a pol- lutant has been sufficiently diluted to meet discharge...PS releases, e.g. DISPER or TADPOL (Almquist et al. 1977) for passive mixing in the far field, and various jet and plume mixing models in uniform or...Experiment Station, Vicksburg, MS. Harleman, D. R. F. 1982 (Mar). " Hydrothermal Analysis of Lakes and Reser- voirs, Journal of Hydraulics Division

  20. Rotor for processing liquids using movable capillary tubes

    DOEpatents

    Johnson, W.F.; Burtis, C.A.; Walker, W.A.

    1987-07-17

    A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described. 5 figs.

  1. Characterization of the major aroma-active compounds in mango (Mangifera indica L.) cultivars Haden, White Alfonso, Praya Sowoy, Royal Special, and Malindi by application of a comparative aroma extract dilution analysis.

    PubMed

    Munafo, John P; Didzbalis, John; Schnell, Raymond J; Schieberle, Peter; Steinhaus, Martin

    2014-05-21

    The aroma-active compounds present in tree-ripened fruits of the five mango (Mangifera indica L.) cultivars Haden, White Alfonso, Praya Sowoy, Royal Special, and Malindi were isolated by solvent extraction followed by solvent-assisted flavor evaporation (SAFE) and analyzed by gas chromatography-olfactometery (GC-O). Application of a comparative aroma extract dilution analysis (cAEDA) afforded 54 aroma-active compounds in the flavor dilution (FD) factor range from 4 to ≥2048, 16 of which are reported for the first time in mango. The results of the identification experiments in combination with the FD factors revealed 4-hydroxy-2,5-dimethyl-3(2H)-furanone as an important aroma compound in all cultivars analyzed. Twenty-seven aroma-active compounds were present in at least one mango cultivar at an FD factor ≥128. Clear differences in the FD factors of these odorants between each of the mango cultivars suggested that they contributed to the unique sensory profiles of the individual cultivars.

  2. Reductive amination derivatization for the quantification of garlic components by isotope dilution analysis.

    PubMed

    Lin, Yi-Reng; Huang, Mei-Fang; Wu, You-Ying; Liu, Meng-Chieh; Huang, Jing-Heng; Chen, Ziyu; Shiue, Yow-Ling; Wu, Chia-En; Liang, Shih-Shin

    2017-09-01

    In this work, we synthesized internal standards for four garlic organosulfur compounds (OSCs) by reductive amination with 13 C, D 2 -formaldehyde, and developed an isotope dilution analysis method to quantitate these organosulfur components in garlic samples. Internal standards were synthesized for internal absolute quantification of S-allylcysteine (SAC), S-allylcysteine sulfoxide (alliin), S-methylcysteine (SMC), and S-ethylcysteine (SEC). We used a multiple reaction monitoring (MRM) to detect 13 C, D 2 -formaldehyde-modified OSCs by ultrahigh-performance liquid phase chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and obtained MS spectra showing different ratios of 13 C, D 2 -formaldehyde-modified and H 2 -formaldehyde-modified compounds. The resulting labeled and unlabeled OSCs were exhibited correlation coefficient (R 2 ) ranged from 0.9989 to 0.9994, respectively. The average recoveries for four OSCs at three concentration levels ranged from 89% to 105%. By 13 C, D 2 -formaldehyde and sodium cyanoborohydride, the reductive amination-based method can be utilized to generate novel internal standard for isotope dilution and to extend the quantitative application. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Comparative techno-economic analysis of steam explosion, dilute sulfuric acid, ammonia fiber explosion and biological pretreatments of corn stover.

    PubMed

    Baral, Nawa Raj; Shah, Ajay

    2017-05-01

    Pretreatment is required to destroy recalcitrant structure of lignocelluloses and then transform into fermentable sugars. This study assessed techno-economics of steam explosion, dilute sulfuric acid, ammonia fiber explosion and biological pretreatments, and identified bottlenecks and operational targets for process improvement. Techno-economic models of these pretreatment processes for a cellulosic biorefinery of 113.5 million liters butanol per year excluding fermentation and wastewater treatment sections were developed using a modelling software-SuperPro Designer. Experimental data of the selected pretreatment processes based on corn stover were gathered from recent publications, and used for this analysis. Estimated sugar production costs ($/kg) via steam explosion, dilute sulfuric acid, ammonia fiber explosion and biological methods were 0.43, 0.42, 0.65 and 1.41, respectively. The results suggest steam explosion and sulfuric acid pretreatment methods might be good alternatives at present state of technology and other pretreatment methods require research and development efforts to be competitive with these pretreatment methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Verification of key odorants in rose oil by gas chromatography-olfactometry/aroma extract dilution analysis, odour activity value and aroma recombination.

    PubMed

    Xiao, Zuobing; Li, Jing; Niu, Yunwei; Liu, Qiang; Liu, Junhua

    2017-10-01

    Rose oil is much too expensive but very popular. It's well known that the flower oil's aroma profile hasn't been intensively investigated. In order to verify the aroma profile of rose oil, the synthetic blend of odorants was prepared and then compared with the original rose oil using electronic nose analysis (ENA) combined with quantitative descriptive analysis (QDA). The odorants from rose oils were screened out by Gas Chromatography-Olfactometry/aroma extract dilution analysis (GC-O/AEDA) combined with odour activity value (OAV). Both ENA and QDA indicated the recombination model derived from OAV and GC-O/AEDA closely resembled the original rose oil. The experiment results show that rose oxide, linalool, α-pinene, β-pinene, nonanal, heptanal citronellal, phenyl ethyl alcohol, benzyl alcohol, eugenol, methyl eugenol, β-citronellol, hexyl acetate, β-ionone, nerol, etc. are very important constituent to rose oil aroma profile.

  5. Noninvasive measurement of smoking-associated N(3)-ethyladenine and N(7)-ethylguanine in human salivary DNA by stable isotope dilution nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry.

    PubMed

    Chen, Hauh-Jyun Candy; Lin, Chao-Ray

    2014-02-10

    Evidence showed that ethylating agents are contained in cigarette smoke, which damage DNA producing ethylated DNA adducts, including N(3)-ethyladenine (3-EtAde) and N(7)-ethylguanine (7-EtGua). These two ethylpurines can be depurinated spontaneously and be repaired by enzymes and they have been detected in human urine. In this study, a highly specific and sensitive assay based on stable isotope dilution nanoflow liquid chromatography nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) was used to measure 3-EtAde and 7-EtGua in human salivary DNA. These ethylpurines were released from DNA by neutral thermal hydrolysis and then enriched by a solid-phase extraction column before nanoLC-NSI/MS/MS analysis. The detection limits (S/N≥3) of 3-EtA and 7-EtG were 15 fg (92 amol) and 10 fg (56 amol), respectively, injected on-column. The lower quantification limits of 3-EtAde and 7-EtGua were both 100 fg, i.e. 620 and 560 amol, respectively, corresponding to 9.4 and 8.6 adducts in 10(9) normal nucleotides, respectively, starting with as little as 20 μg of DNA isolated from an average of 3 mL of saliva. The mean (±SD) levels of 3-EtAde in 15 smokers and 15 nonsmokers were 12.6±7.0 and 9.7±5.3 in 10(8) normal nucleotides, respectively, while those of 7-EtGua were 14.1±8.2 and 3.8±2.8 in 10(8) normal nucleotides in smokers and nonsmokers, respectively. Levels of 7-EtGua, but not 3-EtAde, were statistically significantly higher in smokers than in nonsmokers (p<0.0001). Furthermore, salivary 7-EtGua levels are significantly correlated with the number of cigarettes smoked per day as well as with the smoking index. This highly specific and sensitive stable isotope dilution nanoLC-NSI/MS/MS assay might be feasible in measuring 7-EtGua in human salivary DNA as a noninvasive biomarker for DNA damage induced by cigarette smoking. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Energy-Efficient Bioalcohol Recovery by Gel Stripping

    NASA Astrophysics Data System (ADS)

    Godbole, Rutvik; Ma, Lan; Hedden, Ronald

    2014-03-01

    Design of energy-efficient processes for recovering butanol and ethanol from dilute fermentations is a key challenge facing the biofuels industry due to the high energy consumption of traditional multi-stage distillation processes. Gel stripping is an alternative purification process by which a dilute alcohol is stripped from the fermentation product by passing it through a packed bed containing particles of a selectively absorbent polymeric gel material. The gel must be selective for the alcohol, while swelling to a reasonable degree in dilute alcohol-water mixtures. To accelerate materials optimization, a combinatorial approach is taken to screen a matrix of copolymer gels having orthogonal gradients in crosslinker concentration and hydrophilicity. Using a combination of swelling in pure solvents, the selectivity and distribution coefficients of alcohols in the gels can be predicted based upon multi-component extensions of Flory-Rehner theory. Predictions can be validated by measuring swelling in water/alcohol mixtures and conducting h HPLC analysis of the external liquid. 95% + removal of butanol from dilute aqueous solutions has been demonstrated, and a mathematical model of the unsteady-state gel stripping process has been developed. NSF CMMI Award 1335082.

  7. Transient finite element analysis of electric double layer using Nernst-Planck-Poisson equations with a modified Stern layer.

    PubMed

    Lim, Jongil; Whitcomb, John; Boyd, James; Varghese, Julian

    2007-01-01

    A finite element implementation of the transient nonlinear Nernst-Planck-Poisson (NPP) and Nernst-Planck-Poisson-modified Stern (NPPMS) models is presented. The NPPMS model uses multipoint constraints to account for finite ion size, resulting in realistic ion concentrations even at high surface potential. The Poisson-Boltzmann equation is used to provide a limited check of the transient models for low surface potential and dilute bulk solutions. The effects of the surface potential and bulk molarity on the electric potential and ion concentrations as functions of space and time are studied. The ability of the models to predict realistic energy storage capacity is investigated. The predicted energy is much more sensitive to surface potential than to bulk solution molarity.

  8. Identification of Ginger (Zingiber officinale Roscoe) Volatiles and Localization of Aroma-Active Constituents by GC-Olfactometry.

    PubMed

    Pang, Xueli; Cao, Jianmin; Wang, Dabin; Qiu, Jun; Kong, Fanyu

    2017-05-24

    For the characterization of chemical components contributing to the aroma of ginger, which could benefit the development of deep-processed ginger products, volatile extracts were isolated by a combination of direct solvent extraction-solvent-assisted flavor evaporation and static headspace analysis. Aroma-impact components were identified by gas chromatography-olfactometry-mass spectrometry, and the most potent odorants were further screened by aroma extract dilution analysis (AEDA) and static headspace dilution analysis (SHDA). The AEDA results revealed that geranial, eucalyptol, β-linalool, and bornyl acetate were the most potent odorants, exhibiting the highest flavor dilution factor (FD factor) of 2187. SHDA indicated that the predominant headspace odorants were α-pinene and eucalyptol. In addition, odorants exhibiting a high FD factor in SHDA were estimated to be potent aroma contributors in AEDA. The predominant odorants were found to be monoterpenes and sesquiterpenes, as along with their oxygenated derivatives, providing minty, lemon-like, herbal, and woody aromas. On the other hand, three highly volatile compounds detected by SHDA were not detected by AEDA, whereas 34 high-polarity, low-volatility compounds were identified only by AEDA, demonstrating the complementary natures of SHDA and AEDA and the necessity of utilizing both techniques to accurately characterize the aroma of ginger.

  9. High preservation of DNA standards diluted in 50% glycerol.

    PubMed

    Schaudien, Dirk; Baumgärtner, Wolfgang; Herden, Christiane

    2007-09-01

    Standard curves are important tools in real-time quantitative polymerase chain reaction (PCR) to precisely analyze gene expression patterns under physiologic and pathologic conditions. Handling of DNA standards often implies multiple cycles of freezing and thawing that might affect DNA stability and integrity. This in turn might influence the reliability and reproducibility of quantitative measurements in real-time PCR assays. In this study, 3 DNA standards such as murine tumor necrosis factor (TNF) alpha, interferon (IFN) gamma, and kainat-1 receptor were diluted in 50% glycerol or water after 1, 4, and 16 cycles of freezing and thawing and amplified copy numbers after real-time PCR were compared. The standards diluted in water showed a reduction to 83%, 55%, and 50% after 4 cycles, to 24%, 5%, and 4% after 16 cycles for kainat-1 receptor, TNFalpha, and IFNgamma standards, respectively, when compared with a single cycle of freezing and thawing. Interestingly, all cDNA samples diluted in 50% glycerol were amplified in comparable copy numbers even after 16 cycles of freezing and thawing. The effect of the standards undergoing different cycles of freezing and thawing on sample values was demonstrated by amplifying cDNA obtained from Borna disease virus infected and noninfected TNF-transgenic mice brain. This revealed significant differences of measured cDNA copy numbers using water-diluted DNA standards. In contrast, sample values did not vary using glycerol-diluted standards that were frozen and thawed for 16 times. In conclusion, glycerol storage of DNA standards represents a suitable tool for the accurate and reproducible quantification of cDNA samples in real-time PCR analysis.

  10. [Evaluation of visualization of biological stains with the use of alternative light source (ALS) for the purpose of genetic identification. Part I. Blood and saliva stains analysis].

    PubMed

    Szeremeta, Michał; Pepiński, Witold; Niemcunowicz-Janica, Anna; Skawrońska, Małgorzata; Sackiewicz, Adam; Ptaszyńska-Sarosiek, Iwona; Okłota, Magdalena

    2010-01-01

    The objective of the investigation was evaluation of visualization of human blood and saliva stains with the use of alternative light source for the purpose of genetic identification. Experimental bloodstains on the bright base were the most clearly seen in the natural light and white light, up to blood dilution of 1:600. Complete typeability of AmpFISTR SGM Plus kit profiles was obtained from bloodstains at dilution 1:1500. Partial AmpFISTR SGM Plus kit profiles were typed from bloodstains at dilutions 1:1750 and 1:2000. Experimental saliva stains on the light-colored base were completely invisible in the natural light and white light, while they were visualized at wavelength range 300-415 nm through yellow goggles, and at wavelength range 300-455 nm through orange goggles at saliva dilution 1: 600. Complete typeability of AmpFISTR SGM Plus kit loci was obtained from saliva stains at dilution 1:1750. Partial AmpFISTR SGM Plus kit profiles were typed from saliva stains at dilution 1:2000. The wavelength of 455 nm and orange goggles were the optimal set for visualization of bloodstains on various, noncontrasting materials. Other useful wavelength/combinations of goggles were CSS light/red goggles. In case of saliva, the most useful general condition for visualization of stains on various, non-contrasting materials was with the wavelength set to 300-415 nm, while wearing yellow goggles. Other useful combinations of wavelength/goggles were 300-455 nm/orange or red goggles, and also CSS light/orange or red goggles.

  11. Lattice Boltzmann scheme for mixture modeling: analysis of the continuum diffusion regimes recovering Maxwell-Stefan model and incompressible Navier-Stokes equations.

    PubMed

    Asinari, Pietro

    2009-11-01

    A finite difference lattice Boltzmann scheme for homogeneous mixture modeling, which recovers Maxwell-Stefan diffusion model in the continuum limit, without the restriction of the mixture-averaged diffusion approximation, was recently proposed [P. Asinari, Phys. Rev. E 77, 056706 (2008)]. The theoretical basis is the Bhatnagar-Gross-Krook-type kinetic model for gas mixtures [P. Andries, K. Aoki, and B. Perthame, J. Stat. Phys. 106, 993 (2002)]. In the present paper, the recovered macroscopic equations in the continuum limit are systematically investigated by varying the ratio between the characteristic diffusion speed and the characteristic barycentric speed. It comes out that the diffusion speed must be at least one order of magnitude (in terms of Knudsen number) smaller than the barycentric speed, in order to recover the Navier-Stokes equations for mixtures in the incompressible limit. Some further numerical tests are also reported. In particular, (1) the solvent and dilute test cases are considered, because they are limiting cases in which the Maxwell-Stefan model reduces automatically to Fickian cases. Moreover, (2) some tests based on the Stefan diffusion tube are reported for proving the complete capabilities of the proposed scheme in solving Maxwell-Stefan diffusion problems. The proposed scheme agrees well with the expected theoretical results.

  12. Hybrid Vapor Stripping-Vapor Permeation Process for Recovery and Dehydration of 1-Butanol and Acetone/Butanol/Ethanol from Dilute Aqueous Solutions. Part 1. Process Simulations

    EPA Science Inventory

    BACKGROUND: Fermentative production of butanol is limited to low concentrations, typically less than 2 wt% solvent, due to product inhibition. The result is high separation energy demand by conventional distillation approaches, despite favorable vapor-liquid equilibrium and parti...

  13. Mean-field theory of spin-glasses with finite coordination number

    NASA Technical Reports Server (NTRS)

    Kanter, I.; Sompolinsky, H.

    1987-01-01

    The mean-field theory of dilute spin-glasses is studied in the limit where the average coordination number is finite. The zero-temperature phase diagram is calculated and the relationship between the spin-glass phase and the percolation transition is discussed. The present formalism is applicable also to graph optimization problems.

  14. Continuous aryl alcohol oxidase production under growth-limited conditions using a trickle bed reactor.

    PubMed

    Pardo-Planas, Oscar; Atiyeh, Hasan K; Prade, Rolf A; Müller, Michael; Wilkins, Mark R

    2018-05-01

    An A. nidulans strain with a pyridoxine marker was used for continuous production of aryl alcohol oxidase (AAO) in a trickle bed reactor (TBR). Modified medium with reduced zinc, no copper, and 5 g/L ascorbic acid that reduced melanin production and increased AAO productivity under growth limited conditions was used. Two air flow rates, 0.11 L/min (0.1 vvm) and 1.1 L/min (1.0 vvm) were tested. More melanin formation and reduced protein productivity were observed with air flow rate of 1.1 L/min. Three random packings were used as support for the fungus inside the TBR column, two of which were hydrophobic and one which was hydrophilic, and three different dilution rates were tested. The use of GEA BCN 030 hydrophobic packing resulted in greater AAO yield and productivity than the other packings. Increasing dilution rates favored melanin formation and citric, lactic and succinic acid accumulation, which decreased AAO yield and productivity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Determination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.

    PubMed

    Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis

    2011-10-01

    A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.

  16. UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome.

    PubMed

    Khoshneviszadeh, Rabea; Fazly Bazzaz, Bibi Sedigheh; Housaindokht, Mohammad Reza; Ebrahim-Habibi, Azadeh; Rajabi, Omid

    2015-01-01

    The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg/mL range of hydroquinone analyte with a regression coefficient of 0.9998. This study showed that the liposomal hydroquinone composed of phospholipid (7.8 %), cholesterol (1.5 %), alpha ketopherol (0.17 %) and hydroquinone (0.5 %) did not absorb wavelength of 293 nm if it diluted 500 times by methanol. The concentration of hydroquinone reached 10 µg/mL after 500 times of dilution. Furthermore, various validation parameters as per ICH Q2B guideline were tested and found accordingly. The recovery percentages of liposomal hydroquinone were found 102 ± 0.8, 99 ± 0.2 and 98 ± 0.4 for 80%, 100% and 120% respectively. The relative standard deviation values of inter and intra-day precisions were <%2. LOD and LOQ were 0.24 and 0.72 µg/mL respectively.

  17. Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Aszyk, Justyna; Kubica, Paweł; Kot-Wasik, Agata; Namieśnik, Jacek; Wasik, Andrzej

    2017-10-13

    Liquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI-MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace ® Ultracore™ SuperC18™ (100×2.1mm, 2.5μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple "dilute & shoot" approach was used for the sample preparation. The method validation was performed by evaluating key analytical parameters such as linearity, accuracy, selectivity, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curves showed good linearity within the specific ranges for the investigated compounds with correlation coefficients greater than 0.990 in each case. The recovery for all the investigated compounds varied from 89% to 110%. The intra- and inter-day precision were within the acceptable limits (±15%) at all tested concentrations. The applicability of the methods was examined by analysing 25 liquid samples from e-cigarettes commercially available on the Polish market. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Use of recombinantly produced 15N3-labelled nicotianamine for fast and sensitive stable isotope dilution ultra-performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Schmidt, Holger; Böttcher, Christoph; Trampczynska, Aleksandra; Clemens, Stephan

    2011-01-01

    Nicotianamine (NA) is an important metal chelator, implicated in the intra- and intercellular trafficking of several transition metal ions in plants. To decipher its roles in physiological processes such as micronutrient acquisition, distribution or storage, fast and sensitive analytical techniques for quantification of this non-proteinogenic amino acid will be required. The use of a recombinant Schizosaccharomyces pombe strain expressing a nicotianamine synthase (NAS) gene allowed for the production of [(15)N(3)]-NA, which was enriched from cell extracts through cation exchange and used for stable isotope dilution analysis of NA. Such an approach should be widely applicable to important bioanalytes that are difficult to synthesize. The analytical procedure comprises mild aqueous extraction and rapid Fmoc derivatization, followed by fast separation using ultra-performance liquid chromatography (UPLC) and sensitive detection by positive ion electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) with a chromatographic cycle time of only 8 min. Derivatization was optimized with respect to incubation time and species suitable for quantification. The limit of detection was 0.14 to 0.23 pmol in biological matrices with the response being linear up to 42 pmol. Recovery rates were between 83% and 104% in various biological matrices including fission yeast cells, fungal mycelium, plant leaves and roots.

  19. [Determination of endogenous agmatine in rat plasma by isotope dilution-gas chromatography-mass spectrometry].

    PubMed

    Qiu, Zhongli; Lin, Ying; Xiong, Zhili; Xie, Jianwei

    2014-07-01

    A method for the determination of endogenous agmatine in rat plasma was developed by isotope dilution-gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS). The plasma samples were analyzed after protein precipitation, evaporation, derivatization by hexafluoroacetone (HFAA), and clean-up on a Florisil SPE column. The GC-MS analysis utilized stable isotope d8-agmatine as internal standard. The samples after treatme were tested by negative chemical ionization with selected ion monitoring (SIM) which was set at m/z 492 (molecular ion of agmatine) and m/z 500 (molecular ion of internal standard). The limit of detection (LOD) of agmatine standard solution was 0.005 7 ng/mL. The calibration curve of the agmatine spiked in rat plasma showed a good linear relationship at the range of 1.14-57.0 ng/mL (r = 0.997). The recoveries of agmatine spiked in rat plasma ranged from 92.3% to 109.8%. Inter-day and intra-day precisions were less than 15%. The average concentration level of agmatine in rat plasma was (22 +/- 9) ng/mL, and there was no significant difference between male and female SD rats (p > 0.05). The method is high sensitive and specific, and can be used for the determination of endogenous agmatine in plasma. It provides a strong support for the subsequent research of agmatine.

  20. Method of determining the optimal dilution ratio for fluorescence fingerprint of food constituents.

    PubMed

    Trivittayasil, Vipavee; Tsuta, Mizuki; Kokawa, Mito; Yoshimura, Masatoshi; Sugiyama, Junichi; Fujita, Kaori; Shibata, Mario

    2015-01-01

    Quantitative determination by fluorescence spectroscopy is possible because of the linear relationship between the intensity of emitted fluorescence and the fluorophore concentration. However, concentration quenching may cause the relationship to become nonlinear, and thus, the optimal dilution ratio has to be determined. In the case of fluorescence fingerprint (FF) measurement, fluorescence is measured under multiple wavelength conditions and a method of determining the optimal dilution ratio for multivariate data such as FFs has not been reported. In this study, the FFs of mixed solutions of tryptophan and epicatechin of different concentrations and composition ratios were measured. Principal component analysis was applied, and the resulting loading plots were found to contain useful information about each constituent. The optimal concentration ranges could be determined by identifying the linear region of the PC score plotted against total concentration.

  1. Constraining the Volatility Distributions and Possible Diffusion Limitations of Secondary Organic Aerosols Using Laboratory Dilution Experiments

    NASA Astrophysics Data System (ADS)

    Ye, Q.; Robinson, E. S.; Mahfouz, N.; Sullivan, R. C.; Donahue, N. M.

    2016-12-01

    Secondary organic aerosols (SOA) dominate the mass of fine particles in the atmosphere. Their formation involves both oxidation of volatile organics from various sources that produce products with uncertain volatilities, and diffusion of these products into the condensed phase. Therefore, constraining volatility distribution and diffusion timescales of the constituents in SOA are important in predicting size, concentration and composition of SOA, as well as how these properties of SOA evolve in the atmosphere. In this work, we demonstrate how carefully designed laboratory isothermal dilution experiments in smog chambers can shed light into the volatility distribution and any diffusion barriers of common types of SOA over time scales relevant to atmospheric transport and diurnal cycling. We choose SOA made from mono-terpenes (alpha-pinene and limonene) and toluene to represent biogenic and anthropogenic SOA. We look into how moisture content can alter any evaporation behaviors of SOA by varying relative humidity during SOA generation and during dilution process. This provides insight into whether diffusion in the condensed phase is rate limiting in reaching gas/particle equilibrium of semi-volatile organic compounds. Our preliminary results show that SOA from alpha-pinene evaporates continuously over several hours of experiments, and there is no substantial discernible differences over wide ranges of the chamber humidity. SOA from toluene oxidation shows slower evaporation. We fit these experimental data using absorptive partitioning theory and a particle dynamic model to obtain volatility distributions and to predict particle size evolution. This in the end will help us to improve representation of SOA in large scale chemical transport models.

  2. Evaluation of Commercially Available Chikungunya Virus Immunoglobulin M Detection Assays

    PubMed Central

    Johnson, Barbara W.; Goodman, Christin H.; Holloway, Kimberly; de Salazar, P. Martinez; Valadere, Anne M.; Drebot, Michael A.

    2016-01-01

    Commercial chikungunya virus (CHIKV)–specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA had high performance at CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. PMID:26976887

  3. LC/MS/MS analysis of the endogenous dimethyltryptamine hallucinogens, their precursors, and major metabolites in rat pineal gland microdialysate.

    PubMed

    Barker, Steven A; Borjigin, Jimo; Lomnicka, Izabela; Strassman, Rick

    2013-12-01

    We report a qualitative liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous analysis of the three known N,N-dimethyltryptamine endogenous hallucinogens, their precursors and metabolites, as well as melatonin and its metabolic precursors. The method was characterized using artificial cerebrospinal fluid (aCSF) as the matrix and was subsequently applied to the analysis of rat brain pineal gland-aCSF microdialysate. The method describes the simultaneous analysis of 23 chemically diverse compounds plus a deuterated internal standard by direct injection, requiring no dilution or extraction of the samples. The results demonstrate that this is a simple, sensitive, specific and direct approach to the qualitative analysis of these compounds in this matrix. The protocol also employs stringent MS confirmatory criteria for the detection and confirmation of the compounds examined, including exact mass measurements. The excellent limits of detection and broad scope make it a valuable research tool for examining the endogenous hallucinogen pathways in the central nervous system. We report here, for the first time, the presence of N,N-dimethyltryptamine in pineal gland microdialysate obtained from the rat. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Multi-laboratory survey of qPCR enterococci analysis method performance

    EPA Pesticide Factsheets

    Quantitative polymerase chain reaction (qPCR) has become a frequently used technique for quantifying enterococci in recreational surface waters, but there are several methodological options. Here we evaluated how three method permutations, type of mastermix, sample extract dilution and use of controls in results calculation, affect method reliability among multiple laboratories with respect to sample interference. Multiple samples from each of 22 sites representing an array of habitat types were analyzed using EPA Method 1611 and 1609 reagents with full strength and five-fold diluted extracts. The presence of interference was assessed three ways: using sample processing and PCR amplifications controls; consistency of results across extract dilutions; and relative recovery of target genes from spiked enterococci in water sample compared to control matrices with acceptable recovery defined as 50 to 200%. Method 1609, which is based on an environmental mastermix, was found to be superior to Method 1611, which is based on a universal mastermix. Method 1611 had over a 40% control assay failure rate with undiluted extracts and a 6% failure rate with diluted extracts. Method 1609 failed in only 11% and 3% of undiluted and diluted extracts analyses. Use of sample processing control assay results in the delta-delta Ct method for calculating relative target gene recoveries increased the number of acceptable recovery results. Delta-delta tended to bias recoveries fr

  5. Effect of the dilution rate on microbial competition: r-strategist can win over k-strategist at low substrate concentration.

    PubMed

    Winkler, Mari-K H; Boets, Pieter; Hahne, Birk; Goethals, Peter; Volcke, Eveline I P

    2017-01-01

    The conditions present in both in vitro and in vivo ecosystems determine the microbial population harbouring it. One commonly accepted theory is that a species with a high substrate affinity and low growth rate (k-strategist) will win the competition against a second species with a lower substrate affinity and higher growth rate (r-strategist) if both species are subjected to low substrate concentrations. In this study two nitrite oxidizing bacteria (NOB), Nitrospira defluvii (k-strategist) and Nitrobacter vulgaris (r-strategist), were cultivated in a continuous reactor systems. The minimal hydraulic retention time (HRT) required for maintaining the slower growing Nitrospira was first determined. A reactor containing Nitrobacter was set to the same HRT and Nitrospira was injected to evaluate the effect of the dilution rate on the competition between both species. By following the microbial population dynamics with qPCR analysis, it was shown that not only the substrate affinity drives the competition between k- and r-strategists but also the dilution rate. Experimental data and numerical simulations both revealed that the washout of Nitrobacter was significantly delayed at dilution rates close to the μmax of Nitrospira. The competition could be even reverted towards Nitrobacter (r-strategist) despite of low nitrite concentrations and dilution rates lower than the μmax of Nitrospira.

  6. Effectiveness of qPCR permutations, internal controls and dilution as means for minimizing the impact of inhibition while measuring Enterococcus in environmental waters.

    PubMed

    Cao, Y; Griffith, J F; Dorevitch, S; Weisberg, S B

    2012-07-01

      Draft criteria for the optional use of qPCR for recreational water quality monitoring have been published in the United States. One concern is that inhibition of the qPCR assay can lead to false-negative results and potentially inadequate public health protection. We evaluate the effectiveness of strategies for minimizing the impact of inhibition.   Five qPCR method permutations for measuring Enterococcus were challenged with 133 potentially inhibitory fresh and marine water samples. Serial dilutions were conducted to assess Enterococcus target assay inhibition, to which inhibition identified using four internal controls (IC) was compared. The frequency and magnitude of inhibition varied considerably among qPCR methods, with the permutation using an environmental master mix performing substantially better. Fivefold dilution was also effective at reducing inhibition in most samples (>78%). ICs were variable and somewhat ineffective, with 54-85% agreement between ICs and serial dilution.   The current IC methods appear to not accurately predict Enterococcus inhibition and should be used with caution; fivefold dilution and the use of reagents designed for environmental sample analysis (i.e. more robust qPCR chemistry) may be preferable.   Suitable approaches for defining, detecting and reducing inhibition will improve implementation of qPCR for water monitoring. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  7. Effect of Melanin Free Ink Extracted From Squid (Loligo sp.) on Proximate and Sensory Characteristics of Soft-Bone Milkfish (Chanos chanos) During Storage

    NASA Astrophysics Data System (ADS)

    Winarni Agustini, Tri; Hadiyanto; Wijayanti, Ima; Amalia, Ulfah; Benjakul, Soottawat

    2018-02-01

    Antioxidant could be extracted and isolated from squid inks. Squid ink in the form of melanin free ink (MFI) could be act as an electron donor which can stabilize free radicals in lipid oxidation. This study was carried out to assess the antioxidant activity of squid inks converted into MFI in different dilution and to optimize the extraction conditions for the application of MFI as an antioxidative agent on fish product. Three different types of MFI extracts i.e : pure squid ink, squid ink with 5 times dilution and squid ink with 10 times dilutions by using cooled ionized water (4°C). The ink was then centrifuged at 18.000 x g for 30 minutes at cooled centrifuge (4°C) followed by DPPH analysis. The results showed that the IC50 of MFI extracts were 2.84 ppm; 1.11 ppm and 0.34 ppm, respectively (p < 0.05). The results indicated that squid ink with 10 times dilution in extraction of MFI had the highest value in free radical inhibitory. Although the IC50 of three different dilutions are equally low, and are considered as very strong antioxidative agent, however, it showed that the MFI extracted from squid ink had the ability to prevent free radical

  8. Effect of dilution temperature on boar semen quality.

    PubMed

    López Rodríguez, A; Rijsselaere, T; Vyt, P; Van Soom, A; Maes, D

    2012-10-01

    As boar semen is very sensitive to cold shock and changes in temperature during semen processing can have a profound impact on semen quality, the effect of the extender temperature at the time of dilution was investigated in a two-step dilution protocol for boar semen being processed for liquid storage. Fifteen boars of different breeds and ages from a commercial artificial insemination centre were included. One ejaculate per boar was collected and processed with Beltsville Thawing Solution semen extender. Each ejaculate was diluted (1 : 1) at 30 °C, and subsequently, the samples were diluted (30 × 10(6) sperm/ml) with either preheated extender [29.3 °C ± 0.2 °C, group A (GA)] or extender at room temperature [22.7 °C ± 0.6 °C, group B (GB)]. Samples were transported to the Faculty of Veterinary Medicine (University of Ghent, Belgium) in two isotherm boxes (one per group), stored at 17 °C and investigated for three consecutive days (D0 to D2). At D0, D1 and D2, motility parameters [computer-assisted semen analysis (CASA)] and the per cent of sperm with intact membrane (% IM) by eosin nigrosin staining were evaluated. At D0 and D2, the % of sperm with intact acrosome (% IA) was studied by Pisum sativum agglutinin staining. The average temperature of the 1 : 1 dilution was 29.4 °C ± 1.1 °C immediately after extender addition. No significant differences were found between groups for per cent motility [79.3 ± 9.0 for GA and 81.1 ± 9.2 for GB (p = 0.372)], % progressive motility [56.5 ± 13.3 for GA and 58.4 ± 13.8 for GB (p = 0.737)] or any CASA parameter. No differences were found for % IM [85.1 ± 10.7 and 84.5 ± 3.8 for GA and GB, respectively (p = 0.761)] and % IA [72.2 ± 9.4 for GA and 68.3 ± 16.6 for GB (p = 0.792)]. In conclusion, when a two-step dilution is performed, preheating the extender for the second dilution to match the semen temperature did not result in better semen quality compared to a dilution at a moderate room temperature. © 2011 Blackwell Verlag GmbH.

  9. Relative effectiveness of kinetic analysis vs single point readings for classifying environmental samples based on community-level physiological profiles (CLPP)

    NASA Technical Reports Server (NTRS)

    Garland, J. L.; Mills, A. L.; Young, J. S.

    2001-01-01

    The relative effectiveness of average-well-color-development-normalized single-point absorbance readings (AWCD) vs the kinetic parameters mu(m), lambda, A, and integral (AREA) of the modified Gompertz equation fit to the color development curve resulting from reduction of a redox sensitive dye from microbial respiration of 95 separate sole carbon sources in microplate wells was compared for a dilution series of rhizosphere samples from hydroponically grown wheat and potato ranging in inoculum densities of 1 x 10(4)-4 x 10(6) cells ml-1. Patterns generated with each parameter were analyzed using principal component analysis (PCA) and discriminant function analysis (DFA) to test relative resolving power. Samples of equivalent cell density (undiluted samples) were correctly classified by rhizosphere type for all parameters based on DFA analysis of the first five PC scores. Analysis of undiluted and 1:4 diluted samples resulted in misclassification of at least two of the wheat samples for all parameters except the AWCD normalized (0.50 abs. units) data, and analysis of undiluted, 1:4, and 1:16 diluted samples resulted in misclassification for all parameter types. Ordination of samples along the first principal component (PC) was correlated to inoculum density in analyses performed on all of the kinetic parameters, but no such influence was seen for AWCD-derived results. The carbon sources responsible for classification differed among the variable types with the exception of AREA and A, which were strongly correlated. These results indicate that the use of kinetic parameters for pattern analysis in CLPP may provide some additional information, but only if the influence of inoculum density is carefully considered. c2001 Elsevier Science Ltd. All rights reserved.

  10. Assessment of a bedside test for N-terminal pro B-type natriuretic peptide (NT-proBNP) to differentiate cardiac from non-cardiac causes of pleural effusion in cats.

    PubMed

    Wurtinger, Gabriel; Henrich, Estelle; Hildebrandt, Nicolai; Wiedemann, Nicola; Schneider, Matthias; Hassdenteufel, Esther

    2017-12-20

    Cats with pleural effusion represent common emergencies in small animal practice. The aim of this prospective study was to investigate the diagnostic ability of a point-of-care ELISA (POC-ELISA) for the measurement of N-terminal pro B-type natriuretic peptide (NT-proBNP) to differentiate cardiac from non-cardiac disease in cats with pleural effusion. The sample material for use of this rapid test was either plasma or diluted pleural effusion. Twenty cats with moderate to severe pleural effusion were prospectively recruited. The cats were grouped into two groups, with or without congestive heart failure (CHF; N-CHF), after complete work-up. Blood and effusion were collected in EDTA tubes. Plasma and pleural effusion supernatants were transferred into stabilizer tubes and frozen. POC-ELISA for NT-proBNP was performed with plasma and diluted effusion (1:1). Quantitative NT-proBNP measurement was performed in plasma and diluted and undiluted effusions. Six cats were assigned to the CHF group. Of the 14 cats in the N-CHF group, 6 had concurrent cardiac abnormalities that were not responsible for the effusion. For the detection of CHF, the test displayed respective sensitivities and specificities of 100% and 79% in plasma and 100% and 86% in diluted pleural fluid. Receiver operating characteristic (ROC) analysis for quantitative NT-proBNP measurement of plasma and diluted and undiluted pleural effusions displayed areas under the curve of 0.98, sensitivities of 100% and specificities of 86%. The optimum cut-off was calculated at 399 pmol/l in plasma and 229 pmol/l in the diluted effusion and 467 pmol/l in the undiluted effusion. POC-ELISA for NT-proBNP in both plasma and diluted pleural effusion was suitable to differentiate cardiac from non-cardiac causes of feline pleural effusion. According to our results, use of pleural effusion is feasible, but dilution of the effusion before measurement seems to improve specificity.

  11. Dilution Confusion: Conventions for Defining a Dilution

    ERIC Educational Resources Information Center

    Fishel, Laurence A.

    2010-01-01

    Two conventions for preparing dilutions are used in clinical laboratories. The first convention defines an "a:b" dilution as "a" volumes of solution A plus "b" volumes of solution B. The second convention defines an "a:b" dilution as "a" volumes of solution A diluted into a final volume of "b". Use of the incorrect dilution convention could affect…

  12. "Micro to macro (M2M)"--A novel approach for intravenous delivery of propofol.

    PubMed

    Damitz, Robert; Chauhan, Anuj

    2015-10-15

    Propofol emulsions have limited shelf life and safety concerns for injection. Microemulsions of propofol are thermodynamically stable and simpler to manufacture, but cause additional pain on injection. We propose a novel micro to macro (M2M) approach of destabilizing a microemulsion immediately prior to injection. Microemulsions of propofol were prepared at two to three times the drug loadings of commercial formulations. We determined suitable microemulsion compositions which destabilize into macroemulsions after two or three fold dilutions with water. Droplet growth after dilution was measured with dynamic light scattering. Increasing solution turbidity after dilution was also measured optically with millisecond resolution. Experimental data was analyzed in the context of a coalescence model. Microemulsions rapidly coalesce into larger droplet size macroemulsions after dilution according to the phase diagram shift. The resulting macroemulsions are metastable retaining their droplet size for several hours. Droplet growth occurs on the order of seconds and a metastable size of about 1 micron is reached in minutes. Rates of droplet growth and metastable droplet sizes depend on the surfactant composition. The coalescence model predicts droplet growth with good agreement but only after accounting for the finite probability of coalescence from each collision. The M2M concept has been demonstrated for the anesthetic drug propofol which may improve stability and manufacturability in addition to reducing pain on injection. This approach could be adapted to other hydrophobic vesicant drugs as well. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. METHOD FOR PREPARING NORMORPHINE

    DOEpatents

    Rapoport, H.; Look, M.

    1959-06-01

    An improved method is presented for producing normorphine from morphine. Morphine as the starting material is acetylated by treatment with acetylating agents to produce di-acetyl morphine (heroin). The acetylated compound is reacted with cyanating agents to produce di-acetyl-cyanonormorphine (cyanonorheroin). The di-acetyl-cyanonormorphine compound is then treated in accordance with the improved hydrolysis reactions of the present invention in which concentrated hydrochloric acid is employed for a limited time period to hydrolyze the acetyl group therefrom forming cyanonormorphine. Subsequently, the reaction mixture is diluted and hydrolysis of the cyano groups from the cyanonormorphine is effected with a longer contact time with dilute hydrochloric acid thereby producing normorphine. A high over-all conversion and production of a high purity product which may be radioactlvely labeled, if desired, is obtained by operation of the process.

  14. Gradient, contact-free volume transfers minimize compound loss in dose-response experiments.

    PubMed

    Harris, David; Olechno, Joe; Datwani, Sammy; Ellson, Richard

    2010-01-01

    More accurate dose-response curves can be constructed by eliminating aqueous serial dilution of compounds. Traditional serial dilutions that use aqueous diluents can result in errors in dose-response values of up to 4 orders of magnitude for a significant percentage of a compound library. When DMSO is used as the diluent, the errors are reduced but not eliminated. The authors use acoustic drop ejection (ADE) to transfer different volumes of model library compounds, directly creating a concentration gradient series in the receiver assay plate. Sample losses and contamination associated with compound handling are therefore avoided or minimized, particularly in the case of less water-soluble compounds. ADE is particularly well suited for assay miniaturization, but gradient volume dispensing is not limited to miniaturized applications.

  15. Guideline on Isotope Dilution Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Amy

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. Thismore » method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.« less

  16. Detection limit of Mycobacterium chimaera in water samples for monitoring medical device safety: insights from a pilot experimental series.

    PubMed

    Schreiber, P W; Köhler, N; Cervera, R; Hasse, B; Sax, H; Keller, P M

    2018-07-01

    A growing number of Mycobacterium chimaera infections after cardiosurgery have been reported by several countries. These potentially fatal infections were traced back to contaminated heater-cooler devices (HCDs), which use water as a heat transfer medium. Aerosolization of water contaminated with M. chimaera from HCDs enables airborne transmission to patients undergoing open chest surgery. Infection control teams test HCD water samples for mycobacterial growth to guide preventive measures. The detection limit of M. chimaera in water samples, however, has not previously been investigated. To determine the detection limit of M. chimaera in water samples using laboratory-based serial dilution tests. An M. chimaera strain representative of the international cardiosurgery-associated M. chimaera outbreak was used to generate a logarithmic dilution series. Two different water volumes, 50 and 1000mL, were inoculated, and, after identical processing (centrifugation, decantation, and decontamination), seeded on mycobacteria growth indicator tube (MGIT) and Middlebrook 7H11 solid media. MGIT consistently showed a lower detection limit than 7H11 solid media, corresponding to a detection limit of ≥1.44 × 10 4 cfu/mL for 50mL and ≥2.4cfu/mL for 1000mL water samples. Solid media failed to detect M. chimaera in 50mL water samples. Depending on water volume and culture method, major differences exist in the detection limit of M. chimaera. In terms of sensitivity, 1000mL water samples in MGIT media performed best. Our results have important implications for infection prevention and control strategies in mitigation of the M. chimaera outbreak and healthcare water safety in general. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  17. Quantitative high-performance liquid chromatographic determination of retinoids in human serum using on-line solid-phase extraction and column switching. Determination of 9-cis-retinoic acid, 13-cis-retinoic acid, all-trans-retinoic acid, 4-oxo-all-trans-retinoicacid and 4-oxo-13-cis-retinoic acid.

    PubMed

    Gundersen, T E; Lundanes, E; Blomhoff, R

    1997-03-28

    A fully automated isocratic high-performance liquid chromatographic method for the determination of 9-cis-retinoic acid, 13-cis-retinoic acid, all-trans-retinoic acid, 4-oxo-13-cis-retinoic acid and 4-oxo-all-trans-retinoic acid, has been developed using on-line solid-phase extraction and a column switching technique allowing clean-up and pre-concentration in a single step. A 500-microliter sample of serum was diluted with 750 microliters of a solution containing 20% acetonitrile and the internal standard 9,10-dimethylanthracene. About 1000 microliters of this mixture was injected on a 20 x 4.6 mm I.D. poly ether ether ketone (PEEK) pre-column with titanium frits packed with Bondapak C18, 37-53 microns, 300 A particles. Proteins and very polar compounds were washed out to waste, from the pre-column, with 0.05% trifluoroacetic acid (TFA)-acetonitrile (8.5:1.5, v/v). More than 200 aliquots of diluted serum could be injected on this pre-column before elevated back-pressure enforces replacement. Components retained on the pre-column were backflushed to the analytical column for separation and detection at 360 nm. Baseline separation was achieved using a single 250 x 4.6 mm I.D. Suplex pKb-100 column and a mobile phase containing 69:10:2:16:3 (v/v) of acetonitrile-methanol-n-butanol-2% ammonium acetate-glacial acetic acid. A total time of analysis of less than 30 min, including sample preparation, was achieved. Recoveries were in the range of 79-86%. The limit of detection was 1-7 ng/ml serum and the precision, in the concentration range 20-1000 ng/ml, was between 1.3 and 4.5% for all five compounds. The method was applied for the analysis of human serum after oral administration of 60 mg Roaccutan. The method is well suited for pharmacological studies, while the endogenous levels of some retinoic acid isomers are below the limit of quantitation.

  18. Functional characterization of individual human hematopoietic stem cells cultured at limiting dilution on supportive marrow stromal layers.

    PubMed Central

    Sutherland, H J; Lansdorp, P M; Henkelman, D H; Eaves, A C; Eaves, C J

    1990-01-01

    A major goal of current hematopoiesis research is to develop in vitro methods suitable for the measurement and characterization of stem cells with long-term in vivo repopulating potential. Previous studies from several centers have suggested the presence in normal human or murine marrow of a population of very primitive cells that are biologically, physically, and pharmacologically different from cells detectable by short-term colony assays and that can give rise to the latter in long-term cultures (LTCs) containing a competent stromal cell layer. In this report, we show that such cultures can be used to provide a quantitative assay for human "LTC-initiating cells" based on an assessment of the number of clonogenic cells present after 5-8 weeks. Production of derivative clonogenic cells is shown to be absolutely dependent on the presence of a stromal cell feeder. When this requirement is met, the clonogenic cell output (determined by assessment of 5-week-old cultures) is linearly related to the input cell number over a wide range of cell concentrations. Using limiting dilution analysis techniques, we have established the frequency of LTC-initiating cells in normal human marrow to be approximately 1 per 2 X 10(4) cells and in a highly purified CD34-positive subpopulation to be approximately 1 per 50-100 cells. The proliferative capacity exhibited by individual LTC-initiating cells cultured under apparently identical culture conditions was found to be highly variable. Values for the number of clonogenic cells per LTC-initiating cell in 5-week-old cultures ranged from 1 to 30 (the average being 4) with similar levels being detected in positive 8-week-old cultures. Some LTC-initiating cells are multipotent as evidenced by their generation of erythroid as well as granulopoietic progeny. The availability of a system for quantitative analysis of the proliferative and differentiative behavior of this newly defined compartment of primitive human hematopoietic cells should facilitate future studies of specific genetic or microenvironmental parameters involved in the regulation of these cells. Images PMID:2333304

  19. Numerical Simulation And Experimental Investigation Of The Lift-Off And Blowout Of Enclosed Laminar Flames

    NASA Technical Reports Server (NTRS)

    Venuturmilli, Rajasekhar; Zhang, Yong; Chen, Lea-Der

    2003-01-01

    Enclosed flames are found in many industrial applications such as power plants, gas-turbine combustors and jet engine afterburners. A better understanding of the burner stability limits can lead to development of combustion systems that extend the lean and rich limits of combustor operations. This paper reports a fundamental study of the stability limits of co-flow laminar jet diffusion flames. A numerical study was conducted that used an adaptive mesh refinement scheme in the calculation. Experiments were conducted in two test rigs with two different fuels and diluted with three inert species. The numerical stability limits were compared with microgravity experimental data. Additional normal-gravity experimental results were also presented.

  20. Unexpected random urinary protein:creatinine ratio results–limitations of the pyrocatechol violet-dye method

    PubMed Central

    2013-01-01

    Background For clinicians, it is important to rely on accurate laboratory results for patient care and optimal use of health care resources. We sought to explore our observations that urine protein:creatinine ratios (PrCr) ≥30 mg/mmol are seen not infrequently associated with normal pregnancy outcome. Methods Urine samples were collected prospectively from 160 pregnant women attending high-risk maternity clinics at a tertiary care facility. Urinary protein was measured using a pyrocatechol violet assay and urinary creatinine by an enzymatic method on Vitros analysers. Maternal/perinatal outcomes were abstracted from hospital records. Results 91/233 (39.1%) samples had a PrCr ≥30 mg/mmol, especially when urinary creatinine concentration was <3 mM (94.1%) vs. ≥3 mM (16.4%) (p < 0.001). When using the last sample before delivery, 47/160 (29.4%) had a PrCr ≥30 mg/mmol in diluted urine vs. only 17/160 (15.4%) in more concentrated urine (p < 0.001); PrCr positive results were also more frequent among the 32 (20.0%) women with known normal pregnancy outcome (90.9% vs. 0) (p < 0.001). Using the same analyser, 0.12 g/L urinary protein was ‘detected’ in deionised water. Re-analysis of data from two cohorts revealed substantially less inflation of PrCr in dilute urine using a pyrogallol red assay. Conclusions Random urinary PrCr was overestimated in dilute urine when tested using a common pyrocatechol violet dye-based method. This effect was reduced in cohorts when pyrogallol red assays were used. False positive results can impact on diagnosis and patient care. This highlights the need for both clinical and laboratory quality improvement projects and standardization of laboratory protein measurement. PMID:23865673

  1. Diagnostic Approach for Differentiating Infected from Vaccinated Poultry on the Basis of Antibodies to NS1, the Nonstructural Protein of Influenza A Virus

    PubMed Central

    Tumpey, Terrence M.; Alvarez, Rene; Swayne, David E.; Suarez, David L.

    2005-01-01

    Vaccination programs for the control of avian influenza (AI) in poultry have limitations due to the problem of differentiating between vaccinated and virus-infected birds. We have used NS1, the conserved nonstructural protein of influenza A virus, as a differential diagnostic marker for influenza virus infection. Experimentally infected poultry were evaluated for the ability to induce antibodies reactive to NS1 recombinant protein produced in Escherichia coli or to chemically synthesized NS1 peptides. Immune sera were obtained from chickens and turkeys inoculated with live AI virus, inactivated purified vaccines, or inactivated commercial vaccines. Seroconversion to positivity for antibodies to the NS1 protein was achieved in birds experimentally infected with multiple subtypes of influenza A virus, as determined by enzyme-linked immunosorbent assay (ELISA) and Western blot analysis. In contrast, animals inoculated with inactivated gradient-purified vaccines had no seroconversion to positivity for antibodies to the NS1 protein, and animals vaccinated with commercial vaccines had low, but detectable, levels of NS1 antibodies. The use of a second ELISA with diluted sera identified a diagnostic test that results in seropositivity for antibodies to the NS1 protein only in infected birds. For the field application phase of this study, serum samples were collected from vaccinated and infected poultry, diluted, and screened for anti-NS1 antibodies. Field sera from poultry that received commercial AI vaccines were found to possess antibodies against AI virus, as measured by the standard agar gel precipitin (AGP) test, but they were negative by the NS1 ELISA. Conversely, diluted field sera from AI-infected poultry were positive for both AGP and NS1 antibodies. These results demonstrate the potential benefit of a simple, specific ELISA for anti-NS1 antibodies that may have diagnostic value for the poultry industries. PMID:15695663

  2. Catchment chemostasis revisited: water quality responds differently to variations in weather and climate

    NASA Astrophysics Data System (ADS)

    Godsey, Sarah; Kirchner, James

    2017-04-01

    Solute concentrations in streamflow typically vary systematically with stream discharge, and the resulting concentration-discharge relationships are important signatures of catchment (bio)geochemical processes. Solutes derived from mineral weathering often exhibit decreasing concentrations with increasing flows, suggesting dilution of a kinetically limited weathering flux by a variable flux of water. However, Godsey et al. (2009) showed that concentration-discharge relationships of weathering-derived solutes in 59 headwater catchments were much flatter than this simple dilution model would predict. Instead, their analysis showed that these catchments behaved almost like chemostats, with rates of solute production and/or mobilization that were nearly proportional to water fluxes, on both event and inter-annual time scales. Here we re-examine these findings using data from roughly 1000 catchments, ranging from ˜10 to >1,000,000 km2 in drainage area, and spanning a wide range of lithologic and climatic settings. Concentration-discharge relationships among this much larger set of much larger catchments are broadly consistent with the chemostatic behavior described by Godsey et al. (2009). Among these same catchments, however, site-to-site variations in mean concentrations are strongly (negatively) correlated with long-term average precipitation and discharge, suggesting strong dilution of stream concentrations under long-term leaching of the critical zone. The picture that emerges is one in which, on event and inter-annual time scales, stream solute concentrations are chemostatically buffered by groundwater storage and fast chemical reactions (such as ion exchange), but on much longer time scales, the catchment's chemostatic "set point" is determined by climatically driven critical zone evolution. Examples illustrating the different influences of (short-term) weather and (long-term) climate on water quality will be presented, and their implications will be discussed. Godsey, S.E., J.W. Kirchner and D.W. Clow, Concentration-discharge relationships reflect chemostatic characteristics of US catchments, Hydrological Processes, 23, 1844-1864, 2009.

  3. Shifted termination assay (STA) fragment analysis to detect BRAF V600 mutations in papillary thyroid carcinomas

    PubMed Central

    2013-01-01

    Background BRAF mutation is an important diagnostic and prognostic marker in patients with papillary thyroid carcinoma (PTC). To be applicable in clinical laboratories with limited equipment, diverse testing methods are required to detect BRAF mutation. Methods A shifted termination assay (STA) fragment analysis was used to detect common V600 BRAF mutations in 159 PTCs with DNAs extracted from formalin-fixed paraffin-embedded tumor tissue. The results of STA fragment analysis were compared to those of direct sequencing. Serial dilutions of BRAF mutant cell line (SNU-790) were used to calculate limit of detection (LOD). Results BRAF mutations were detected in 119 (74.8%) PTCs by STA fragment analysis. In direct sequencing, BRAF mutations were observed in 118 (74.2%) cases. The results of STA fragment analysis had high correlation with those of direct sequencing (p < 0.00001, κ = 0.98). The LOD of STA fragment analysis and direct sequencing was 6% and 12.5%, respectively. In PTCs with pT3/T4 stages, BRAF mutation was observed in 83.8% of cases. In pT1/T2 carcinomas, BRAF mutation was detected in 65.9% and this difference was statistically significant (p = 0.007). Moreover, BRAF mutation was more frequent in PTCs with extrathyroidal invasion than tumors without extrathyroidal invasion (84.7% versus 62.2%, p = 0.001). To prepare and run the reactions, direct sequencing required 450 minutes while STA fragment analysis needed 290 minutes. Conclusions STA fragment analysis is a simple and sensitive method to detect BRAF V600 mutations in formalin-fixed paraffin-embedded clinical samples. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5684057089135749 PMID:23883275

  4. Rapid and highly reproducible analysis of rare earth elements by multiple collector inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Baker, Joel; Waight, Tod; Ulfbeck, David

    2002-10-01

    A method has been developed for the rapid chemical separation and highly reproducible analysis of the rare earth elements (REE) by isotope dilution analysis by means of a multiple collector inductively coupled plasma mass spectrometer (MC-ICP-MS). This technique is superior in terms of the analytical reproducibility or rapidity of analysis compared with quadrupole ICP-MS or with thermal ionization mass spectrometric isotope dilution techniques. Samples are digested by standard hydrofluoric-nitric acid-based techniques and spiked with two mixed spikes. The bulk REE are separated from the sample on a cation exchange column, collecting the middle-heavy and light REE as two groups, which provides a middle-heavy REE cut with sufficient separation of the light from the heavier REE to render oxide interferences trivial, and a Ba-free light REE cut. The heavy (Er-Lu), middle (Eu-Gd), and light REE (La-Eu) concentrations are determined by three short (1 to 2 min) analyses with a CETAC Aridus desolvating nebulizer introduction system. Replicate digestions of international rock standards demonstrate that concentrations can be reproduced to <1%, which reflects weighing errors during digestion and aliquotting as inter-REE ratios reproduce to ≤0.2% (2 SD). Eu and Ce anomalies reproduce to <0.15%. In addition to determining the concentrations of polyisotopic REE by isotope dilution analysis, the concentration of monoisotopic Pr can be measured during the light REE isotope dilution run, by reference to Pr/Ce and Pr/Nd ratios measured in a REE standard solution. Pr concentrations determined in this way reproduce to <1%, and Pr/REE ratios reproduce to <0.4%. Ce anomalies calculated with La and Pr also reproduce to <0.15% (2 SD). The precise Ce (and Eu) anomaly measurements should allow greater use of these features in studying the recycling of materials with these anomalies into the mantle, or redox-induced effects on the REE during recycling and dehydration of oceanic lithosphere, partial melting, metamorphism, alteration, or sedimentation processes. Moreover, this technique consumes very small amounts (subnanograms) of the REE and will allow precise REE determinations to be made on much smaller samples than hitherto possible.

  5. Regionalized Lunar South Pole Surface Navigation System Analysis

    NASA Technical Reports Server (NTRS)

    Welch, Bryan W.

    2008-01-01

    Apollo missions utilized Earth-based assets for navigation because the landings took place at lunar locations in constant view from the Earth. The new exploration campaign to the lunar south pole region will have limited Earth visibility, but the extent to which a navigation system comprised solely of Earth-based tracking stations will provide adequate navigation solutions in this region is unknown. This report presents a dilution-of-precision (DoP)-based, stationary surface navigation analysis of the performance of multiple lunar satellite constellations, Earth-based deep space network assets, and combinations thereof. Results show that kinematic and integrated solutions cannot be provided by the Earth-based deep space network stations. Also, the stationary surface navigation system needs to be operated either as a two-way navigation system or as a one-way navigation system with local terrain information, while the position solution is integrated over a short duration of time with navigation signals being provided by a lunar satellite constellation.

  6. Analysis of opposed jet hydrogen-air counter flow diffusion flame

    NASA Technical Reports Server (NTRS)

    Ho, Y. H.; Isaac, K. M.

    1989-01-01

    A computational simulation of the opposed-jet diffusion flame is performed to study its structure and extinction limits. The present analysis concentrates on the nitrogen-diluted hydrogen-air diffusion flame, which provides the basic information for many vehicle designs such as the aerospace plane for which hydrogen is a candidate as the fuel. The computer program uses the time-marching technique to solve the energy and species equations coupled with the momentum equation solved by the collocation method. The procedure is implemented in two stages. In the first stage, a one-step forward overal chemical reaction is chosen with the gas phase chemical reaction rate determined by comparison with experimental data. In the second stage, a complete chemical reaction mechanism is introduced with detailed thermodynamic and transport property calculations. Comparison between experimental extinction data and theoretical predictions is discussed. The effects of thermal diffusion as well as Lewis number and Prandtl number variations on the diffusion flame are also presented.

  7. Identification of synergistic impacts during anaerobic co-digestion of organic wastes.

    PubMed

    Astals, S; Batstone, D J; Mata-Alvarez, J; Jensen, P D

    2014-10-01

    Anaerobic co-digestion has been widely investigated, but there is limited analysis of interaction between substrates. The objective of this work was to assess the role of carbohydrates, protein and lipids in co-digestion behaviour separately, and together. Two sets of batch tests were done, each set consisting of the mono-digestion of three substrates, and the co-digestion of seven mixtures. The first was done with pure substrates--cellulose, casein and olive oil--while in the second slaughterhouse waste--paunch, blood and fat--were used as carbohydrate, protein and lipid sources, respectively. Synergistic effects were mainly improvement of process kinetics without a significant change in biodegradability. Kinetics improvement was linked to the mitigation of inhibitory compounds, particularly fats dilution. The exception was co-digestion of paunch with lipids, which resulted in an improved final yield with model based analysis indicating the presence of paunch improved degradability of the fatty feed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Using Magnetic Fields to Control Convection during Protein Crystallization: Analysis and Validation Studies

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Leslie, F. W.

    2004-01-01

    The effect of convection during the crystallization of proteins is not very well understood. In a gravitational field, convection is caused by crystal sedimentation and by solutal buoyancy induced flow and these can lead to crystal imperfections. While crystallization in microgravity can approach diffusion limited growth conditions (no convection), terrestrially strong magnetic fields can be used to control fluid flow and sedimentation effects. In this work, we develop the analysis for magnetic flow control and test the predictions using analog experiments. Specifically, experiments on solutal convection in a paramagnetic fluid were conducted in a strong magnetic field gradient using a dilute solution of Manganese Chloride. The observed flows indicate that the magnetic field can completely counter the settling effects of gravity locally and are consistent with the theoretical predictions presented. This phenomenon suggests that magnetic fields may be useful in mimicking the microgravity environment of space for some crystal growth ana biological applications where fluid convection is undesirable.

  9. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations.

    PubMed

    Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A

    2011-01-01

    Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.

  10. Proposal of concentration limits for determining the hazard property HP 14 for waste using ecotoxicological tests.

    PubMed

    Hennebert, Pierre

    2018-04-01

    Different ecotoxicological test batteries and concentration limits have been proposed to assess the hazard property (HP) HP 14 'Ecotoxic' for waste in the European Union and its member states. In test batteries, if the concentration of waste in the culture/dilution medium producing 50% of inhibitory biological effect in one or more test(s) is below the concentration limit of the test, the waste is classified as hazardous. A summarized review of the test batteries proposed since 1998 is presented. The last proposed test battery uses seven aquatic and terrestrial species with standardized methods, but with options and uniform concentration limits of 10% of waste eluate or solid waste in the culture/dilution medium. No attempt was made to match this hazard assessment with the classification made in the European List of Waste (LoW). The aim of this paper is to propose for the same test battery (reduced to 6 tests without options) concentration limits that match with the European List of Waste. This list was taken as reference (despite the fact that waste can be hazardous for other properties than the most frequent HP 14, and its partly political nature for some opinions). The concentration limits (CLs) for tests are the concentrations producing the highest ecotoxicological effects for each test observed in a non-hazardous waste set. Data from Germany, France and Belgium (from in total 5 different sources from 2009 to 2016) with the above-mentioned test battery (without options) were gathered for 81 samples, being the largest set ever published. In total, ten non-hazardous (NH) waste samples (as defined by the LoW and for most of them checked by chemical composition) were used to establish CLs. These CLs were then applied to 13 hazardous (H) waste by the LoW, and all were classified as hazardous. The matching of the resulting classification with the LoW is convincing. For the 58 'mirror entries' in the LoW (hazardous or not depending of the presence of hazardous substances), 37 were classified H (64%) and 21 were classified NH (36%). These concentration limits can be refined with the method proposed here, as soon as additional data of NH waste (by list and by composition) are available. The test battery (without options) and the concentration limits (in percent of waste in the culture/dilution medium) proposed are the following: A waste is hazardous for HP 14 'Ecotoxic' if the concentration of waste (eluate or solid) in the culture/dilution medium producing 50% of biological effect relative to the control EC 50 -30 min of Vibrio fischeri (EN ISO 11348-3) is lower than 15.8%, or if the EC 50 -72 h of Pseudokirchneriella subcapitata (EN ISO 8692) is lower than 7.03%, or if the EC 50 -48 h of Daphnia magna (EN ISO 6341) is lower than 7.95%, or if the EC 50 -6h of Arthrobacter globiformis (ISO 18187) is lower than 2.25%, or if the EC 50 -14d of Brassica rapa (EN ISO 11269-2) is lower than 13.7%, or if the EC 50 -48 h of Eisenia fetida avoidance test (ISO 17512-1) is lower than 3.75%. These CLs range between 2% and 16%, which is in line with the typically 10% concentration proposed without validation. To fix regulatory concentration limits, the regulators can use these CLs and the uncertainty of the ecotoxicological tests (standard deviation of inter-laboratory reproducibility typically of 25% of the mean, as published in the standards). Classification of waste for HP 14 with these tests and concentration limits will agree with the European List of Waste. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Stable isotope dilution ultra-high performance liquid chromatography-tandem mass spectrometry quantitative profiling of tryptophan-related neuroactive substances in human serum and cerebrospinal fluid.

    PubMed

    Hényková, Eva; Vránová, Hana Přikrylová; Amakorová, Petra; Pospíšil, Tomáš; Žukauskaitė, Asta; Vlčková, Magdaléna; Urbánek, Lubor; Novák, Ondřej; Mareš, Jan; Kaňovský, Petr; Strnad, Miroslav

    2016-03-11

    Many compounds related to L-tryptophan (L-TRP) have interesting biological or pharmacological activity, and their abnormal neurotransmission seems to be linked to a wide range of neurodegenerative and psychiatric diseases. A high-throughput method based on ultra-high performance liquid chromatography connected to electrospray tandem mass spectrometry (UHPLC-ESI-MS/MS) was developed for the quantitative analysis of L-TRP and 16 of its metabolites in human serum and cerebrospinal fluid (CSF), representing both major and minor routes of L-TRP catabolism. The combination of a fast LC gradient with selective tandem mass spectrometry enabled accurate analysis of almost 100 samples in 24h. The standard isotope dilution method was used for quantitative determination. The method's lower limits of quantification for serum and cerebrospinal fluid ranged from 0.05 to 15nmol/L and 0.3 to 45nmol/L, respectively. Analytical recoveries ranged from 10.4 to 218.1% for serum and 22.1 to 370.0% for CSF. The method's accuracy ranged from 82.4 to 128.5% for serum matrix and 90.7 to 127.7% for CSF matrix. All intra- and inter-day coefficients of variation were below 15%. These results demonstrate that the new method is capable of quantifying endogenous serum and CSF levels of a heterogeneous group of compounds spanning a wide range of concentrations. The method was used to determine the physiological levels of target analytes in serum and CSF samples from 18 individuals, demonstrating its reliability and potential usefulness in large-scale epidemiological studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Isotope dilution technique for quantitative analysis of endogenous trace element species in biological systems

    NASA Astrophysics Data System (ADS)

    Schaumlöffel, Dirk; Lobinski, Ryszard

    2005-04-01

    The aim of this study was to develop an inductively coupled plasma mass spectrometry (ICPMS) method for the determination of enriched species-specific mercury tracers at ng L-1 levels (ppt) in zooplankton and aquatic samples from biological tracer experiments. Applying a cold vapor sector field ICPMS method a high sensitivity was obtained, i.e., 106 cps for 1 [mu]g L-1 of natural mercury measured on 202Hg+, which in turn enabled the measurement of mercury isotope ratios with a 0.6-1.4%R.S.D. precision for a 50 ng L-1 standard. This method was used to quantify CH3201Hg+ and 200Hg2+ tracers in zooplankton from a biological tracer experiment with the aim of investigating the effects of algal density and zooplankton density on mercury bioaccumulation in zooplankton in a fresh water system. For quantification purposes a known amount of 199Hg+ was added to the zooplankton samples before digestion. The digested samples were analyzed and the resulting ICPMS spectra split into four spectra one for each of the four sources of mercury present in the sample (CH3201Hg+, 200Hg2+, 199Hg2+ and natural mercury) using algebraic de-convoluting. The CH3201Hg+ and 200Hg2+ tracers were quantified using an isotope dilution approach with the added 199Hg+. Detection limits were 0.6 and 0.2 ng L-1 for 200Hg+ and CH3201Hg+, respectively. The coefficient of variation on the tracer determinations was approximately 18% CV estimated from the analysis of real samples with tracer concentrations in the <0.1-100 ng L-1 range. The developed method was successfully applied for the determination of species-specific mercury tracers in zooplankton samples from a biological tracer experiment.

  13. Detection of triclocarban and two co-contaminating chlorocarbanilides in US aquatic environments using isotope dilution liquid chromatography tandem mass spectrometry.

    PubMed

    Sapkota, Amir; Heidler, Jochen; Halden, Rolf U

    2007-01-01

    The antimicrobial compound triclocarban (TCC; 3,4,4'-trichlorocarbanilide; CAS# 101-20-2) is a high-production-volume chemical, recently suggested to cause widespread contamination of US water resources. To test this hypothesis, we developed an isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry method for ultratrace analysis of TCC (0.9 ng/L detection limit) and analyzed low-volume water samples (200 mL) along with primary sludge samples from across the United States. All river water samples (100%) collected downstream of wastewater treatment plants had detectable levels of TCC, as compared to 56% of those taken upstream. Concentrations of TCC (mean+/-standard deviation) downstream of sewage treatment plants (84+/-110 ng/L) were significantly higher (P<0.05; Wilcoxon rank sum test) than those of samples taken upstream (12+/-15 ng/L). Compared to surface water, mean TCC concentrations found in dried, primary sludge obtained from municipal sewage treatment plants in five states were six orders of magnitude greater (19,300+/-7100 microg/kg). Several river samples contained a co-contaminant, identified based on its chromatographic retention time, molecular base ion, and MS/MS fragmentation behavior as 4,4'-dichlorocarbanilide (DCC; CAS# 1219-99-4). In addition to TCC and DCC, municipal sludge contained a second co-contaminant, 3,3',4,4'-tetrachlorocarbanilide (TetraCC; CAS# 4300-43-0). Both newly detected compounds were present as impurities (0.2%(w/w) each) in technical grade TCC (99%). Application of the new method for chlorocarbanilide analysis yielded TCC occurrence data for 13 US states, confirmed the role of sewage treatment plants as environmental inputs of TCC, and identified DCC and TetraCC as previously unrecognized pollutants released into the environment alongside TCC.

  14. Electronic cigarette aerosol induces significantly less cytotoxicity than tobacco smoke

    PubMed Central

    Azzopardi, David; Patel, Kharishma; Jaunky, Tomasz; Santopietro, Simone; Camacho, Oscar M.; McAughey, John; Gaça, Marianna

    2016-01-01

    Abstract Electronic cigarettes (E-cigarettes) are a potential means of addressing the harm to public health caused by tobacco smoking by offering smokers a less harmful means of receiving nicotine. As e-cigarettes are a relatively new phenomenon, there are limited scientific data on the longer-term health effects of their use. This study describes a robust in vitro method for assessing the cytotoxic response of e-cigarette aerosols that can be effectively compared with conventional cigarette smoke. This was measured using the regulatory accepted Neutral Red Uptake assay modified for air–liquid interface (ALI) exposures. An exposure system, comprising a smoking machine, traditionally used for in vitro tobacco smoke exposure assessments, was adapted for use with e-cigarettes to expose human lung epithelial cells at the ALI. Dosimetric analysis methods using real-time quartz crystal microbalances for mass, and post-exposure chemical analysis for nicotine, were employed to detect/distinguish aerosol dilutions from a reference Kentucky 3R4F cigarette and two commercially available e-cigarettes (Vype eStick and ePen). ePen aerosol induced 97%, 94% and 70% less cytotoxicity than 3R4F cigarette smoke based on matched EC50 values at different dilutions (1:5 vs. 1:153 vol:vol), mass (52.1 vs. 3.1 μg/cm2) and nicotine (0.89 vs. 0.27 μg/cm2), respectively. Test doses where cigarette smoke and e-cigarette aerosol cytotoxicity were observed are comparable with calculated daily doses in consumers. Such experiments could form the basis of a larger package of work including chemical analyses, in vitro toxicology tests and clinical studies, to help assess the safety of current and next generation nicotine and tobacco products. PMID:27690199

  15. Combination of physico-chemical analysis, Allium cepa test system and Oreochromis niloticus erythrocyte based comet assay/nuclear abnormalities tests for cyto-genotoxicity assessments of treated effluents discharged from textile industries.

    PubMed

    Hemachandra, Chamini K; Pathiratne, Asoka

    2016-09-01

    Bioassays for cyto-genotoxicity assessments are generally not required in current textile industry effluent discharge management regulations. The present study applied in vivo plant and fish based toxicity tests viz. Allium cepa test system and Oreochromis niloticus erythrocyte based comet assay and nuclear abnormalities tests in combination with physico-chemical analysis for assessing potential cytotoxic/genotoxic impacts of treated textile industry effluents reaching a major river (Kelani River) in Sri Lanka. Of the treated effluents tested from two textile industries, color in the Textile industry 1 effluents occasionally and color, biochemical oxygen demand and chemical oxygen demand in the Textile industry 2 effluents frequently exceeded the specified Sri Lankan tolerance limits for discharge of industrial effluents into inland surface waters. Exposure of A. cepa bulbs to 100% and 12.5% treated effluents from both industries resulted in statistically significant root growth retardation, mito-depression, and induction of chromosomal abnormalities in root meristematic cells in comparison to the dilution water in all cases demonstrating cyto-genotoxicity associated with the treated effluents. Exposure of O. niloticus to the 100% and 12.5% effluents, resulted in erythrocytic genetic damage as shown by elevated total comet scores and induction of nuclear abnormalities confirming the genotoxicity of the treated effluents even with 1:8 dilution. The results provide strong scientific evidence for the crucial necessity of incorporating cyto-genotoxicity impact assessment tools in textile industry effluent management regulations considering human health and ecological health of the receiving water course under chronic exposure. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Isotope dilution-GC-MS/MS analysis of 16 polycyclic aromatic hydrocarbons in selected medicinal herbs used as health food additives.

    PubMed

    Yu, L; Cao, Y; Zhang, J; Cui, Z; Sun, H

    2012-01-01

    Medicinal herbs have a very important role in health protection and disease control, and have been used in health foods. Polycyclic aromatic hydrocarbons (PAHs) have carcinogenic, biological and mutagenic effects. In this paper, the content of 16 PAHs as representative contaminants in nine Chinese medicinal herbs, as additives for health foods, was investigated in order to ensure food safety from this source. A highly sensitive isotope dilution-gas chromatography-tandem mass spectrometry (ID-GC-MS/MS) method combined with gel permeation chromatography (GPC) and solid-phase extraction (SPE) was developed. Calibration curves showed good linearity for all PAHs (R² > 0.999), and the limit of quantification (LOQ) ranged from 0.42 to 2.7 µg kg⁻¹. Average recoveries for these compounds were in the range of 52.5-117%, 52.6-119% and 81.4-108% at the concentrations of 10, 50 and 250 µg kg⁻¹ with RSD of 1.8-15%, 0.9-15% and 1.0-15%, respectively. The proposed method was used for the analysis of nine Chinese medicinal herbs. Total levels of PAHs varied from 98.2 µg kg⁻¹ (cassia seed) to 2245 µg kg⁻¹ (eucommia bark). The highest level was found for phenanthrene (Phe) in liquorice root (631.3 µg kg⁻¹), indigowoad leaf (551.0 µg kg⁻¹), rose flower (435.2 µg kg⁻¹) and eucommia bark (432.3 µg kg⁻¹). The proposed method could provide a useful basis for safety monitoring of herbs and risk management for PAHs in the health food industry.

  17. Ultrasensitive determination of cadmium in seawater by hollow fiber supported liquid membrane extraction coupled with graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peng, Jin-feng; Liu, Rui; Liu, Jing-fu; He, Bin; Hu, Xia-lin; Jiang, Gui-bin

    2007-05-01

    A new procedure, based on hollow fiber supported liquid membrane preconcentration coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection, was developed for the determination of trace Cd in seawater samples. With 1-octanol that contained a mixture of dithizone (carrier) and oleic acid immobilized in the pores of the polypropylene hollow fiber as a liquid membrane, Cd was selectively extracted from water samples into 0.05 M HNO 3 that filled the lumen of the hollow fiber as a stripping solution. The main extraction related parameters were optimized, and the effects of salinity and some coexisting interferants were also evaluated. Under the optimum extraction conditions, an enrichment factor of 387 was obtained for a 100-mL sample solution. In combination with graphite furnace atomic absorption spectrometry, a very low detection limit (0.8 ng L - 1 ) and a relative standard deviation (2.5% at 50 ng L - 1 level) were achieved. Five seawater samples were analyzed by the proposed method without dilution, with detected Cd concentration in the range of 56.4-264.8 ng L - 1 and the relative spiked recoveries over 89%. For comparison, these samples were also analyzed by the Inductively Coupled Plasma Mass Spectrometry (ICP-MS) method after a 10-fold dilution for matrix effect elimination. Statistical analysis with a one-way ANOVA shows no significant differences (at 0.05 level) between the results obtained by the proposed and ICP-MS methods. Additionally, analysis of certified reference materials (GBW (E) 080040) shows good agreement with the certified value. These results indicate that this present method is very sensitive and reliable, and can effectively eliminate complex matrix interferences in seawater samples.

  18. Microfocused Ultrasound with Visualization and Calcium Hydroxylapatite for Improving Skin Laxity and Cellulite Appearance

    PubMed Central

    Pereira, Gregório

    2017-01-01

    Background: Age-associated skin laxity contributes to worsening of cellulite appearance. This study evaluated the effects of microfocused ultrasound with visualization (MFU-V; Ultherapy) in combination with diluted calcium hydroxylapatite (CaHA; Radiesse) on cellulite appearance and on neocollagenesis. Methods: Twenty women (18–55 years old) with skin laxity and moderate-to-severe cellulite on the buttocks and thighs were retrospectively enrolled. MFU-V was applied using 4 and 7 MHz transducers (25 lines/transducer/site) and immediately followed by subdermal CaHA injection (1 ml/buttock or thigh). Photographs at baseline and 90 days were assessed by 2 independent, blinded evaluators using a 5-item cellulite severity scale. One subject scheduled for thighplasty received treatment with 6 different CaHA dilutions (0.3 ml/5 cm2) followed by MFU-V. Tissue specimens from each dilution site were examined under polarized light microscopy to assess neocollagenesis. Results: Both evaluators reported statistically significant improvements compared with baseline for each item on the cellulite severity scale (P < 0.001) with a 4.5-point improvement in mean overall score (P < 0.001) after a single MFU-V/CaHA treatment. At 90 days, histologic analysis showed peak neocollagenesis in samples treated with the 1:1 dilution, whether with CaHA alone or in combination with MFU-V. The highest conversion of collagen type III into collagen type I at month 3 occurred in samples injected with 1:1 and 1:0.6 CaHA dilutions without subsequent MFU-V treatment. Both procedures were well tolerated, and subject satisfaction was high. Conclusions: Combination treatment with MFU-V and diluted CaHA is effective for improving skin laxity and the appearance of cellulite on the buttocks and upper thighs. PMID:28831339

  19. RADIOISOTOPES USED IN PHARMACY. 5. IONIZING RADIATION IN PHARMACEUTICAL ANALYSIS (in Danish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kristensen, K.

    1962-09-01

    The use of radioisotope methods for analyzing drugs is reviewed. It is pointed out that heretofore most methods have been based on isotope dilution principles whereas in the future radioactivation analysis, especially with neutron sources, offers great possibilities. (BBB)

  20. Microchip systems for immunoassay: an integrated immunoreactor with electrophoretic separation for serum theophylline determination.

    PubMed

    Chiem, N H; Harrison, D J

    1998-03-01

    A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 +/- 0.03 and an intercept of -0.04 +/- 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 micrograms/L at the detector) was obtained. Recovery values were 107% +/- 8% for 15 mg/L serum samples.

Top