Sample records for linear isokinetics angular

  1. Do isokinetic angular velocity and contraction types affect the predictors of different anaerobic power tests?

    PubMed

    Yapici, Aysegul; Findikoglu, Gulin; Dundar, Ugur

    2016-04-01

    The purpose of this study was to investigate the most important predictor isokinetic muscle strength determined by different angular velocities and contraction types (i.e. concentric and eccentric) for selected anaerobic power tests in volleyball players. Twenty male and ten female amateur volleyball players participated in this study. Selected anaerobic power tests included Wingate Anaerobic Test (WAnT), squat jump (SJ) and countermovement jump (CMJ). Peak torque values were obtained at 60, 120, 240˚/s for concentric contraction of quadriceps (Qconc) and Hamstring (Hconc) and at 60˚/s for eccentric contraction of quadriceps (Qecc) and Hconc. Moderate to good correlations (r:0.409 to r:0.887) were found between anaerobic tests and isokinetic data including peak torque and total work of both Hconc and Qconc at 60, 120, 240°/s and Qecc at 60°/s (P<0.05). Qconc measured at each of 60, 120, 240°/s was found to be the only significant predictor for anaerobic tests in linear regression models (P<0.05). Correlation coefficient s for Qconc increased with increasing velocity for each of the anaerobic tests. Correlation coefficient of Qconc was highest for CMJ followed by SJ and WAnT at the same angular velocity. As a distinctive feature, both Qecc and Hconc at 60˚/s were significantly predictors for CMJ and SJ. Qconc peak torque was the single significant predictor for WAnT, SJ and CMJ and strength of the relation increases with increasing angular velocity. However, both Qecc and Hconc were significant indicators for CMJ and SJ. Training with higher isokinetic angular velocities and with eccentric contraction is desirable in a training program that has a goal of improving anaerobic performance in volleyball players.

  2. A methodologic approach for normalizing angular work and velocity during isotonic and isokinetic eccentric training.

    PubMed

    Guilhem, Gaël; Cornu, Christophe; Guével, Arnaud

    2012-01-01

    Resistance exercise training commonly is performed against a constant external load (isotonic) or at a constant velocity (isokinetic). Researchers comparing the effectiveness of isotonic and isokinetic resistance-training protocols need to equalize the mechanical stimulus (work and velocity) applied. To examine whether the standardization protocol could be adjusted and applied to an eccentric training program. Controlled laboratory study. Controlled research laboratory. Twenty-one sport science male students (age = 20.6 ± 1.5 years, height = 178.0 ± 4.0 cm, mass = 74.5 ± 9.1 kg). Participants performed 9 weeks of isotonic (n = 11) or isokinetic (n = 10) eccentric training of knee extensors that was designed so they would perform the same amount of angular work at the same mean angular velocity. Angular work and angular velocity. The isotonic and isokinetic groups performed the same total amount of work (-185.2 ± 6.5 kJ and -184.4 ± 8.6 kJ, respectively) at the same angular velocity (21 ± 1°/s and 22°/s, respectively) with the same number of repetitions (8.0 and 8.0, respectively). Bland-Altman analysis showed that work (bias = 2.4%) and angular velocity (bias = 0.2%) were equalized over 9 weeks between the modes of training. The procedure developed allows angular work and velocity to be standardized over 9 weeks of isotonic and isokinetic eccentric training of the knee extensors. This method could be useful in future studies in which researchers compare neuromuscular adaptations induced by each type of training mode with respect to rehabilitating patients after musculoskeletal injury.

  3. Relationship between cardiopulmonary responses and isokinetic moments: the optimal angular velocity for muscular endurance

    PubMed Central

    Lee, Chan-Bok; Eun, Denny; Kim, Kang-Ho; Park, Jae-Wan; Jee, Yong-Seok

    2017-01-01

    Most protocols for testing and rehabilitation for recovery and improvement of muscular endurance have been set at 180°/sec, 240°/sec, and 300°/sec. These protocols can cause confusion to clinical providers or other researchers. This study was aimed at investigating the optimal isokinetic angular speed for measuring or developing muscular endurance after assessing the relationship between cardiopulmonary responses and isokinetic moments. This study was conducted with 31 male and female college students. Graded exercise test and body composition were measured as well as the isokinetic moments of the knee muscles at three angular speeds: 180°/sec, 240°/sec, and 300°/sec. The specific isokinetic moments of knee muscles that were measured included: peak torque (PT) and total work (TW) on extensor (e) and flexor (f) of knee joints, which were denoted as ePT180, fPT180, eTW180, fTW180, ePT240, fPT240, eTW240, fTW240, ePT300, fPT300, eTW300, and fTW300 according to the three angular speeds. Spearman correlation test was used to examine the relationship between the sum means of cardiopulmonary responses and the variables of isokinetic moments. This study confirmed that the optimal angular speed for testing or training for muscular endurance was 180°/sec, which showed a stronger relationship between cardiopulmonary responses and isokinetic moments. Therefore, this angular speed is recommended for testing and training for muscular endurance of the knee joints. PMID:28503531

  4. Relationship between cardiopulmonary responses and isokinetic moments: the optimal angular velocity for muscular endurance.

    PubMed

    Lee, Chan-Bok; Eun, Denny; Kim, Kang-Ho; Park, Jae-Wan; Jee, Yong-Seok

    2017-04-01

    Most protocols for testing and rehabilitation for recovery and improvement of muscular endurance have been set at 180°/sec, 240°/sec, and 300°/sec. These protocols can cause confusion to clinical providers or other researchers. This study was aimed at investigating the optimal isokinetic angular speed for measuring or developing muscular endurance after assessing the relationship between cardiopulmonary responses and isokinetic moments. This study was conducted with 31 male and female college students. Graded exercise test and body composition were measured as well as the isokinetic moments of the knee muscles at three angular speeds: 180°/sec, 240°/sec, and 300°/sec. The specific isokinetic moments of knee muscles that were measured included: peak torque (PT) and total work (TW) on extensor (e) and flexor (f) of knee joints, which were denoted as ePT180, fPT180, eTW180, fTW180, ePT240, fPT240, eTW240, fTW240, ePT300, fPT300, eTW300, and fTW300 according to the three angular speeds. Spearman correlation test was used to examine the relationship between the sum means of cardiopulmonary responses and the variables of isokinetic moments. This study confirmed that the optimal angular speed for testing or training for muscular endurance was 180°/sec, which showed a stronger relationship between cardiopulmonary responses and isokinetic moments. Therefore, this angular speed is recommended for testing and training for muscular endurance of the knee joints.

  5. A Methodologic Approach for Normalizing Angular Work and Velocity During Isotonic and Isokinetic Eccentric Training

    PubMed Central

    Guilhem, Gaël; Cornu, Christophe; Guével, Arnaud

    2012-01-01

    Context: Resistance exercise training commonly is performed against a constant external load (isotonic) or at a constant velocity (isokinetic). Researchers comparing the effectiveness of isotonic and isokinetic resistance-training protocols need to equalize the mechanical stimulus (work and velocity) applied. Objective: To examine whether the standardization protocol could be adjusted and applied to an eccentric training program. Design: Controlled laboratory study. Setting: Controlled research laboratory. Patients or Other Participants: Twenty-one sport science male students (age = 20.6 ± 1.5 years, height = 178.0 ± 4.0 cm, mass = 74.5 ± 9.1 kg). Intervention(s): Participants performed 9 weeks of isotonic (n = 11) or isokinetic (n = 10) eccentric training of knee extensors that was designed so they would perform the same amount of angular work at the same mean angular velocity. Main Outcome Measure(s): Angular work and angular velocity. Results: The isotonic and isokinetic groups performed the same total amount of work (−185.2 ± 6.5 kJ and −184.4 ± 8.6 kJ, respectively) at the same angular velocity (21 ± 1°/s and 22°/s, respectively) with the same number of repetitions (8.0 and 8.0, respectively). Bland-Altman analysis showed that work (bias = 2.4%) and angular velocity (bias = 0.2%) were equalized over 9 weeks between the modes of training. Conclusions: The procedure developed allows angular work and velocity to be standardized over 9 weeks of isotonic and isokinetic eccentric training of the knee extensors. This method could be useful in future studies in which researchers compare neuromuscular adaptations induced by each type of training mode with respect to rehabilitating patients after musculoskeletal injury. PMID:22488276

  6. Angular velocity affects trunk muscle strength and EMG activation during isokinetic axial rotation.

    PubMed

    Fan, Jian-Zhong; Liu, Xia; Ni, Guo-Xin

    2014-01-01

    To evaluate trunk muscle strength and EMG activation during isokinetic axial rotation at different angular velocities. Twenty-four healthy young men performed isokinetic axial rotation in right and left directions at 30, 60, and 120 degrees per second angular velocity. Simultaneously, surface EMG was recorded on external oblique (EO), internal oblique (IO), and latissimus dorsi (LD) bilaterally. In each direction, with the increase of angular velocity, peak torque decreased, whereas peak power increased. During isokinetic axial rotation, contralateral EO as well as ipsilateral IO and LD acted as primary agonists, whereas, ipsilateral EO as well as contralateral IO and LD acted as primary antagonistic muscles. For each primary agonist, the root mean square values decreased with the increase of angular velocity. Antagonist coactiviation was observed at each velocity; however, it appears to be higher with the increase of angular velocity. Our results suggest that velocity of rotation has great impact on the axial rotation torque and EMG activity. An inverse relationship of angular velocity was suggested with the axial rotation torque as well as root mean square value of individual trunk muscle. In addition, higher velocity is associated with higher coactivation of antagonist, leading to a decrease in torque with the increase of velocity.

  7. Hamstrings to quadriceps peak torque ratios diverge between sexes with increasing isokinetic angular velocity.

    PubMed

    Hewett, Timothy E; Myer, Gregory D; Zazulak, Bohdanna T

    2008-09-01

    Our purpose was to determine if females demonstrate decreased hamstrings to quadriceps peak torque (H/Q) ratios compared to males and if H/Q ratios increase with increased isokinetic velocity in both sexes. Maturation disproportionately increases hamstrings peak torque at high velocity in males, but not females. Therefore, we hypothesised that mature females would demonstrate decreased H/Q ratios compared to males and the difference in H/Q ratio between sexes would increase as isokinetic velocity increased. Studies that analysed the H/Q ratio with gravity corrected isokinetic strength testing reported between 1967 and 2004 were included in our review and analysis. Keywords were hamstrings/quadriceps, isokinetics, peak torque and gravity corrected. Medline and Smart databases were searched combined with cross-checked bibliographic reference lists of the publications to determine studies to be included. Twenty-two studies were included with a total of 1568 subjects (1145 male, 423 female). Males demonstrated a significant correlation between H/Q ratio and isokinetic velocity (R=0.634, p<0.0001), and a significant difference in the isokinetic H/Q ratio at the lowest angular velocity (47.8+/-2.2% at 30 degrees /s) compared to the highest velocity (81.4+/-1.1% at 360 degrees /s, p<0.001). In contrast, females did not demonstrate a significant relationship between H/Q ratio and isokinetic velocity (R=0.065, p=0.77) or a change in relative hamstrings strength as the speed increased (49.5+/-8.8% at 30 degrees /s; 51.0+/-5.7% at 360 degrees /s, p=0.84). Gender differences in isokinetic H/Q ratios were not observed at slower angular velocities. However, at high knee flexion/extension angular velocities, approaching those that occur during sports activities, significant gender differences were observed in the H/Q ratio. Females, unlike males, do not increase hamstrings to quadriceps torque ratios at velocities that approach those of functional activities.

  8. The Relationships Among Isokinetic Endurance, Initial Strength Level, and Fiber Type.

    ERIC Educational Resources Information Center

    Clarkson, Priscilla M.; And Others

    1982-01-01

    Knee extension isokinetic peak torque was assessed at four angular velocities, and isokinetic endurance was assessed in eight college age men. Muscle fiber type was determined and related to isokinetic strength and fatigability. Results indicate that factors other than fiber type and initial strength level must influence the rate of isokinetic…

  9. A Novel Two-Velocity Method for Elaborate Isokinetic Testing of Knee Extensors.

    PubMed

    Grbic, Vladimir; Djuric, Sasa; Knezevic, Olivera M; Mirkov, Dragan M; Nedeljkovic, Aleksandar; Jaric, Slobodan

    2017-09-01

    Single outcomes of standard isokinetic dynamometry tests do not discern between various muscle mechanical capacities. In this study, we aimed to (1) evaluate the shape and strength of the force-velocity relationship of knee extensors, as observed in isokinetic tests conducted at a wide range of angular velocities, and (2) explore the concurrent validity of a simple 2-velocity method. Thirteen physically active females were tested for both the peak and averaged knee extensor concentric force exerted at the angular velocities of 30°-240°/s recorded in the 90°-170° range of knee extension. The results revealed strong (0.960

  10. Assessment of isokinetic knee strength in elite young female basketball players: correlation with vertical jump.

    PubMed

    Rouis, M; Coudrat, L; Jaafar, H; Filliard, J-R; Vandewalle, H; Barthelemy, Y; Driss, T

    2015-12-01

    To explore the isokinetic concentric strength of the knee muscle groups, and the relationship between the isokinetic knee extensors strength and the vertical jump performance in young elite female basketball players. Eighteen elite female basketball players performed a countermovement jump, and an isokinetic knee test using a Biodex dynamometer. The maximal isokinetic peak torque of the knee extensor and flexor muscles was recorded at four angular velocities (90°/s, 180°/s, 240°/s and 300°/s) for the dominant and non-dominant legs. The conventional hamstring/quadriceps ratio (H/Q) was assessed at each angular velocity for both legs. There was no significant difference between dominant and non-dominant leg whatever the angular velocity (all P>0.05). However, the H/Q ratio enhanced as the velocity increased from 180°/s to 300°/s (P<0.05). Furthermore, low to high significant positive correlations were detected between the isokinetic measures of the knee extensors and the vertical jump height. The highest one was found for the knee extensors peak torque at a velocity of 240°/s (r=0.88, P<0.001). The results accounted for an optimal velocity at which a strong relationship could be obtained between isokinetic knee extensors strength and vertical jump height. Interestingly, the H/Q ratio of the young elite female basketball players in the present study was unusual as it was close to that generally observed in regular sportsmen.

  11. Test-retest reliability of lower limb isokinetic endurance in COPD: A comparison of angular velocities

    PubMed Central

    Ribeiro, Fernanda; Lépine, Pierre-Alexis; Garceau-Bolduc, Corine; Coats, Valérie; Allard, Étienne; Maltais, François; Saey, Didier

    2015-01-01

    Background The purpose of this study was to determine and compare the test-retest reliability of quadriceps isokinetic endurance testing at two knee angular velocities in patients with chronic obstructive pulmonary disease (COPD). Methods After one familiarization session, 14 patients with moderate to severe COPD (mean age 65±4 years; forced expiratory volume in 1 second (FEV1) 55%±18% predicted) performed two quadriceps isokinetic endurance tests on two separate occasions within a 5–7-day interval. Quadriceps isokinetic endurance tests consisted of 30 maximal knee extensions at angular velocities of 90° and 180° per second, performed in random order. Test-retest reliability was assessed for peak torque, muscle endurance, work slope, work fatigue index, and changes in FEV1 for dyspnea and leg fatigue from rest to the end of the test. The intraclass correlation coefficient, minimal detectable change, and limits of agreement were calculated. Results High test-retest reliability was identified for peak torque and muscle total work at both velocities. Work fatigue index was considered reliable at 90° per second but not at 180° per second. A lower reliability was identified for dyspnea and leg fatigue scores at both angular velocities. Conclusion Despite a limited sample size, our findings support the use of a 30-maximal repetition isokinetic muscle testing procedure at angular velocities of 90° and 180° per second in patients with moderate to severe COPD. Endurance measurement (total isokinetic work) at 90° per second was highly reliable, with a minimal detectable change at the 95% confidence level of 10%. Peak torque and fatigue index could also be assessed reliably at 90° per second. Evaluation of dyspnea and leg fatigue using the modified Borg scale of perceived exertion was poorly reliable and its clinical usefulness is questionable. These results should be useful in the design and interpretation of future interventions aimed at improving muscle endurance in COPD. PMID:26124656

  12. The Relationship between Pedal Force and Crank Angular Velocity in Sprint Cycling.

    PubMed

    Bobbert, Maarten Frank; Casius, L J Richard; Van Soest, Arthur J

    2016-05-01

    Relationships between tangential pedal force and crank angular velocity in sprint cycling tend to be linear. We set out to understand why they are not hyperbolic, like the intrinsic force-velocity relationship of muscles. We simulated isokinetic sprint cycling at crank angular velocities ranging from 30 to 150 rpm with a forward dynamic model of the human musculoskeletal system actuated by eight lower extremity muscle groups. The input of the model was muscle stimulation over time, which we optimized to maximize average power output over a cycle. Peak tangential pedal force was found to drop more with crank angular velocity than expected based on intrinsic muscle properties. This linearizing effect was not due to segmental dynamics but rather due to active state dynamics. Maximizing average power in cycling requires muscles to bring their active state from as high as possible during shortening to as low as possible during lengthening. Reducing the active state is a relatively slow process, and hence must be initiated a certain amount of time before lengthening starts. As crank angular velocity goes up, this amount of time corresponds to a greater angular displacement, so the instant of switching off extensor muscle stimulation must occur earlier relative to the angle at which pedal force was extracted for the force-velocity relationship. Relationships between pedal force and crank angular velocity in sprint cycling do not reflect solely the intrinsic force-velocity relationship of muscles but also the consequences of activation dynamics.

  13. Older men are more fatigable than young when matched for maximal power and knee extension angular velocity is unconstrained.

    PubMed

    Dalton, Brian H; Power, Geoffrey A; Paturel, Justin R; Rice, Charles L

    2015-06-01

    The underlying factors related to the divergent findings of age-related fatigue for dynamic tasks are not well understood. The purpose here was to investigate age-related fatigability and recovery between a repeated constrained (isokinetic) and an unconstrained velocity (isotonic) task, in which participants performed fatiguing contractions at the velocity (isokinetic) or resistance (isotonic) corresponding with maximal power. To compare between tasks, isotonic torque-power relationships were constructed prior to and following both fatiguing tasks and during short-term recovery. Contractile properties were recorded from 9 old (~75 years) and 11 young (~25 years) men during three testing sessions. In the first session, maximal power was assessed, and sessions 2 and 3 involved an isokinetic or an isotonic concentric fatigue task performed until maximal power was reduced by 40 %. Compared with young, the older men performed the same number of contractions to task failure for the isokinetic task (~45 contractions), but 20 % fewer for the isotonic task (p < 0.05). Regardless of age and task, maximal voluntary isometric contraction strength, angular velocity, and power were reduced by ~30, ~13, and ~25 %, respectively, immediately following task failure, and only isometric torque was not recovered fully by 10 min. In conclusion, older men are more fatigable than the young when performing a repetitive maximal dynamic task at a relative resistance (isotonic) but not an absolute velocity (isokinetic), corresponding to maximal power.

  14. The isokinetic strength profile of elite soccer players according to playing position

    PubMed Central

    Grygorowicz, Monika; Hojszyk, Radosław; Jadczak, Łukasz

    2017-01-01

    The aim of this study was to compare isokinetic strength performance profiles in elite soccer players across different field positions. A total of 111 elite international players of Polish Ekstraklasa (the top division in Poland) were examined during the 2010–2015 seasons. The players were classified into six positional roles: central defenders (CD), external defenders (ED), central midfielders (CM), external midfielders (EM), forwards (F), and goalkeepers (G). The concentric isokinetic strength (peak torque [PT] of quadriceps and hamstrings, H/Q ratios) was calculated for the dominant leg and the non-dominant leg at angular velocity of 1.05 rad ·s–1, whereas to assess isokinetic muscle endurance, the total work [TW] at angular velocity of 4.19 rad ·s–1, was taken into consideration. The results showed that isokinetic strength performance varies significantly among players in different playing positions. The analysis of PT for quadriceps (PT-Q) and hamstrings (PT-H) generally showed that the goalkeepers and central midfielders had lower strength levels compared to other playing positions. In the case of PT-H and hamstring/quadricep (H/Q) peak torque ratios, statistically significant differences were also noted for the legs, where mean values noted for the dominant leg were higher than for the non-dominant leg. For TW for quadriceps (TW-Q) and hamstrings (TW-H), statistically significant differences were noted only between playing positions. TW-Q values for goalkeepers were lower than for central defenders and external midfielders. TW-H values for goalkeepers were lower than for central midfielders, central defenders and external midfielders. This study showed that specific functional activity of players in individual positions on the field influences the varied profile of isokinetic strength performance. PMID:28759603

  15. The isokinetic strength profile of elite soccer players according to playing position.

    PubMed

    Śliwowski, Robert; Grygorowicz, Monika; Hojszyk, Radosław; Jadczak, Łukasz

    2017-01-01

    The aim of this study was to compare isokinetic strength performance profiles in elite soccer players across different field positions. A total of 111 elite international players of Polish Ekstraklasa (the top division in Poland) were examined during the 2010-2015 seasons. The players were classified into six positional roles: central defenders (CD), external defenders (ED), central midfielders (CM), external midfielders (EM), forwards (F), and goalkeepers (G). The concentric isokinetic strength (peak torque [PT] of quadriceps and hamstrings, H/Q ratios) was calculated for the dominant leg and the non-dominant leg at angular velocity of 1.05 rad ·s-1, whereas to assess isokinetic muscle endurance, the total work [TW] at angular velocity of 4.19 rad ·s-1, was taken into consideration. The results showed that isokinetic strength performance varies significantly among players in different playing positions. The analysis of PT for quadriceps (PT-Q) and hamstrings (PT-H) generally showed that the goalkeepers and central midfielders had lower strength levels compared to other playing positions. In the case of PT-H and hamstring/quadricep (H/Q) peak torque ratios, statistically significant differences were also noted for the legs, where mean values noted for the dominant leg were higher than for the non-dominant leg. For TW for quadriceps (TW-Q) and hamstrings (TW-H), statistically significant differences were noted only between playing positions. TW-Q values for goalkeepers were lower than for central defenders and external midfielders. TW-H values for goalkeepers were lower than for central midfielders, central defenders and external midfielders. This study showed that specific functional activity of players in individual positions on the field influences the varied profile of isokinetic strength performance.

  16. Isokinetic Evaluation of the Hip Flexor and Extensor Muscles: A Systematic Review.

    PubMed

    Zapparoli, Fabricio Yuri; Riberto, Marcelo

    2017-11-01

    Isokinetic dynamometry testing is a safe and reliable method accepted as the "gold standard" in the evaluation of muscle strength in the open kinetic chain. Isokinetic hip examinations face problems in the standardization of the position of the equipment axis, in the individual being examined, and in the adjustment of the lever arm and in stabilization strategies for the patients during the tests. Identification of the methodologic procedures with best reproducibility is also needed. To review the literature to evaluate the parameters used for the isokinetic evaluation of the hip flexor and extensor muscles and its reproducibility. This is a systematic literature review of the Cochrane, LILACS, PEDro, PubMed, and SciELO databases. The inclusion criteria were articles on the evaluation of hip flexor and/or extensor muscular strength with an isokinetic dynamometer and articles that analyzed the ICC or Pearson's reproducibility. The information extracted was positioning of the patient; positioning of the dynamometer axis; positioning of the lever arm; angular speed; sample size, pathology; type of contraction; and ICC and Pearson's results. 204 articles were found, from which 14 were selected that evaluated hip flexor and extensor muscles, involving 550 individuals who were submitted to an isokinetic hip evaluation. Five articles obtained the best result in reproducibility and had their methodology analyzed. To obtain better reproducibility of the isokinetic evaluation of the hip flexor and extensor muscles, the following recommendations must be followed: the individual must be positioned in the supine position and the dynamometer axis must be aligned with the greater trochanter of the femur. The positioning of the lever arm must be in the most distal region of the thigh possible. The angular speed used to analyze torque peak and muscle work was 60°/s, and to evaluate the muscle power it was 180°/s, with concentric and eccentric contractions being analyzed.

  17. Isokinetic hamstrings-to-quadriceps peak torque ratio: the influence of sport modality, gender, and angular velocity.

    PubMed

    Andrade, Marilia Dos Santos; De Lira, Claudio Andre Barbosa; Koffes, Fabiana De Carvalho; Mascarin, Naryana Cristina; Benedito-Silva, Ana Amélia; Da Silva, Antonio Carlos

    2012-01-01

    The purpose of this study was to determine differences in hamstrings-to-quadriceps (H/Q) peak torque ratios evaluated at different angular velocities between men and women who participate in judo, handball or soccer. A total of 166 athletes, including 58 judokas (26 females and 32 males), 39 handball players (22 females and 17 males), and 69 soccer players (17 females and 52 males), were evaluated using an isokinetic dynamometer. The H/Q isokinetic peak torque ratios were calculated at angular velocities of 1.05 rad · s⁻¹ and 5.23 rad · s⁻¹. In the analysis by gender, female soccer players produced lower H/Q peak torque ratios at 1.05 rad · s⁻¹ than males involved in the same sport. However, when H/Q peak torque ratio was assessed at 5.23 rad · s⁻¹, there were no significant differences between the sexes. In the analysis by sport, there were no differences among females at 1.05 rad · s⁻¹. In contrast, male soccer players had significantly higher H/Q peak torque ratios than judokas (66 ± 12% vs. 57 ± 14%, respectively). Female handball players produced significantly lower peak torque ratios at 5.23 rad · s⁻¹ than judokas or soccer players, whereas males presented no ratio differences among sports At 5.23 rad · s⁻¹. In the analysis by velocity, women's muscular ratios assessed at 1.05 rad · s⁻¹ were significantly lower than at 5.23 rad · s⁻¹ for all sports; among men, only judokas presented lower ratios at 1.05 rad · s⁻¹ than at 5.23 rad · s⁻¹. The present results suggest that sport modality and angular velocity influence the isokinetic strength profiles of men and women.

  18. [Isokinetic profile of knee flexors and extensors in a population of rugby players].

    PubMed

    Larrat, E; Kemoun, G; Carette, P; Teffaha, D; Dugue, B

    2007-06-01

    We aimed to assess the isokinetic profile of the flexor and extensor muscles of the knee within a population of rugby players. This was a descriptive study. The rugby players underwent bilateral isokinetic assessment of knee flexion and extension on a CON-TREX MJ isokinetic dynamometer functioning at four angular frequencies - 90, 120, 180 and 240 degrees/s - in a concentric manner. The isokinetic parameters were peak torque, mean power, and mean work in relation to weight and femoral bicep: quadriceps ratio. The population included 16 "Federal 1" (semi-professional) rugby players with mean age 25 years (range 20-33 years). The players were divided into two groups: "forward" players (props, hookers, second line, third line) and "back" players (scrum, inside, center, wing, tail). The values of the isokinetic parameters did not reveal use of a preferred limb. Consequently, peak torque and mean power were higher in forward players than back players, whereas back players showed a higher relative power throughout the isokinetic test. Among rugby players, forward and back players showed differences in several isokinetic parameters. Accurate knowledge of the equilibrium between the knee's effector muscles is important for stability of the joint, to not only minimize articular accidents but also pinpoint force imbalances, thereby preventing muscular lesions during the sports season.

  19. The acute effect of the tongue position in the mouth on knee isokinetic test performance: a highly surprising pilot study

    PubMed Central

    di Vico, Rosa; Ardigò, Luca Paolo; Salernitano, Gianluca; Chamari, Karim; Padulo, Johnny

    2013-01-01

    Summary The tongue involvement within the isokinetic knee extension/flexion exercises has been investigated. Eighteen participants randomly underwent isokinetic testing at 90 and 180°/s with three different tongue positions: middle position (MID, thrusting on the lingual surface of incisive teeth), lying on the lower arch of the mouth (LOW) and extended up to the palatine spot (UP). Statistical analysis of the data revealed an about 30% significant increase of knee flexion peak torque in UP with respect to MID at both angular speeds. Such a difference could have had a confounding effect on results from numerous past studies using isokinetic knee flexion testing. This study alerts future researchers about standardization of tongue position and warrants further investigations on the explicative processes of this phenomenon. PMID:24596696

  20. Relation between isokinetic muscle strength and functional capacity in recreational athletes with chondromalacia patellae.

    PubMed

    Yildiz, Y; Aydin, T; Sekir, U; Cetin, C; Ors, F; Alp Kalyon, T

    2003-12-01

    To investigate the effects of isokinetic exercise on pain and functional test scores of recreational athletes with chondromalacia patellae (CMP) and to examine the correlation between isokinetic parameters and functional tests or pain score. The functional ability of 30 recreational athletes with unilateral CMP was evaluated using six different tests. Pain scores were assessed during daily activities before and after the treatment protocol. Isokinetic exercise sessions were carried out at angular velocities of 60 degrees /s (25-90 degrees range of flexion) and 180 degrees /s (full range). These sessions were repeated three times a week for six weeks. Quadriceps and hamstring peak torque, total work, and endurance ratios had improved significantly after the treatment, as did the functional parameters and pain scores. There was a poor correlation between the extensor endurance ratio and one leg standing test. A moderate correlation between the visual analogue scale and the extensor endurance ratio or flexion endurance ratio was also found. The isokinetic exercise programme used in this study had a positive effect on muscle strength, pain score, and functional ability of knees with CMP. The improvement in the functional capacity did not correlate with the isokinetic parameters.

  1. Does choice of angular velocity affect pain level during isokinetic strength testing of knee osteoarthritis patients?

    PubMed

    Almosnino, S; Brandon, S C E; Sled, E A

    2012-12-01

    Thigh musculature strength assessment in individuals with knee osteoarthritis is routinely performed in rehabilitative settings. A factor that may influence results is pain experienced during testing. To assess whether pain experienced during isokinetic testing in individuals with knee osteoarthritis is dependent on the angular velocity prescribed. Experimental, repeated measures. University laboratory. Thirty-five individuals (19 women, 16 men) with tibiofemoral osteoarthritis. Participants performed three randomized sets of five maximal concentric extension-flexion repetitions at 60°/s, 90°/s and 120°/s. Pain intensity was measured immediately after the completion of each set. Strength outcomes for each set were the average peak moment. Across gender, pain level was not significantly affected by testing velocity (P=0.18, η(p)(2) =0.05). There was a trend of women reporting more pain than men across all testing velocities, however this comparison did not reach statistical significance (P=0.18, η(p)(2)=0.05). There was a significant main effect of testing velocity on strength, with the highest level attained at 60°/s. However, no difference in strength was noted when testing was performed at 90°/s or 120°/s. A large variation in pain scores within and across conditions and gender was noted, suggesting that at the current stage: 1) isokinetic angular velocity prescription be performed on an individual patient basis; and 2) improvements in the manner pain is recorded are needed in order to reduce the variations in pain scores. Individual prescription of angular velocity may be necessary for optimal strength output and reduction of pain during effort exertion in this patient population.

  2. Muscle activation and the isokinetic torque-velocity relationship of the human triceps surae.

    PubMed

    Harridge, S D; White, M J

    1993-01-01

    The influence of muscle activation and the time allowed for torque generation on the angle-specific torque-velocity relationship of the triceps surae was studied during plantar flexion using supramaximal electrical stimulation and a release technique on six male subjects [mean (SD) age 25 (4) years]. Torque-velocity data were obtained under different levels of constant muscle activation by varying the stimulus frequency and the time allowed for isometric torque generation prior to release and isokinetic shortening. To eliminate the effects of the frequency response on absolute torque the isokinetic data were normalized to the maximum isometric torque values at 0.44 rad. There were no significant differences in the normalized torques generated at any angular velocity using stimulus frequencies of 20, 50 or 80 Hz. When the muscle was stimulated at 50 Hz the torques obtained after a 400 ms and 1 s pre-release isometric contraction did not differ significantly. However, with no pre-release contraction significantly less torque was generated at all angular velocities beyond 1.05 rad.s-1 when compared with either the 200, 400 ms or 1 s condition. With a 200 ms pre-release contraction significantly less torque was generated at angular velocities beyond 1.05 rad.s-1 when compared with the 400 ms or 1 s conditions. It would seem that the major factor governing the shape of the torque-velocity curve at a constant level of muscle activation is the time allowed for torque generation.

  3. Relation between isokinetic muscle strength and functional capacity in recreational athletes with chondromalacia patellae

    PubMed Central

    Yildiz, Y; Aydin, T; Sekir, U; Cetin, C; Ors, F; Alp, K

    2003-01-01

    Objectives: To investigate the effects of isokinetic exercise on pain and functional test scores of recreational athletes with chondromalacia patellae (CMP) and to examine the correlation between isokinetic parameters and functional tests or pain score. Methods: The functional ability of 30 recreational athletes with unilateral CMP was evaluated using six different tests. Pain scores were assessed during daily activities before and after the treatment protocol. Isokinetic exercise sessions were carried out at angular velocities of 60°/s (25–90° range of flexion) and 180°/s (full range). These sessions were repeated three times a week for six weeks. Results: Quadriceps and hamstring peak torque, total work, and endurance ratios had improved significantly after the treatment, as did the functional parameters and pain scores. There was a poor correlation between the extensor endurance ratio and one leg standing test. A moderate correlation between the visual analogue scale and the extensor endurance ratio or flexion endurance ratio was also found. Conclusions: The isokinetic exercise programme used in this study had a positive effect on muscle strength, pain score, and functional ability of knees with CMP. The improvement in the functional capacity did not correlate with the isokinetic parameters. PMID:14665581

  4. Output of skeletal muscle contractions. a study of isokinetic plantar flexion in athletes.

    PubMed

    Fugl-Meyer, A R; Mild, K H; Hörnsten, J

    1982-06-01

    Maximum torques, total work and mean power of isokinetic plantar flexions were measured with simultaneous registrations. The integrated electromyograms (iEMG) were obtained by surface electrodes from all three heads of the m. triceps surae. The method applied offers possibilities for adequate description of dynamic muscular work which in the case of plantar flexion in trained man declines as a negative exponential function of angular motion velocity. The decline is parallel to that of maximum torques. The summed triceps surae iEMG was inversely proportional to the velocity and direct proportional to time suggesting that structural rather than neural factors determine the relationships between velocity of angular motion and maximum torque/total work of single Mmaneuvers. Moreover, the fact that maximum mean power as well as maximum electrical efficiency were reached at the functional velocity of toe-off during gait suggests an influence of pragmatic demands on plantar flexion mechanical output.

  5. Efficacy of kinesio taping on isokinetic quadriceps torque in knee osteoarthritis: a double blinded randomized controlled study.

    PubMed

    Anandkumar, Sudarshan; Sudarshan, Shobhalakshmi; Nagpal, Pratima

    2014-08-01

    Double blind pre-test post-test control group design. To compare the isokinetic quadriceps torque, standardized stair-climbing task (SSCT) and pain during SSCT between subjects diagnosed with knee osteoarthritis pre and post kinesio tape (KT) application with and without tension. Strength of the quadriceps and torque producing capability is frequently found to be compromised in knee osteoarthritis. The efficacy of KT in improving isokinetic quadriceps torque in knee osteoarthritis is unknown, forming the basis for this study. Forty subjects were randomly allocated to either the experimental (therapeutic KT with tension) or control group (sham KT without tension) with the allocation being concealed. Pre and post test measurements of isokinetic quadriceps torque, SSCT and pain during SSCT were carried out by a blinded assessor. A large effect size with significant improvements in the peak quadriceps torque (concentric and eccentric at angular velocities of 90° per second and 120° per second), SSCT and pain were obtained in the experimental group when compared to the control group. Application of therapeutic KT is effective in improving isokinetic quadriceps torque, SSCT and reducing pain in knee osteoarthritis.

  6. Influence of angular velocity on vastus lateralis and rectus femoris oxygenation dynamics during knee extension exercises.

    PubMed

    Denis, Romain; Wilkinson, Jennifer; De Vito, Giuseppe

    2011-09-01

    The purpose of this study was to investigate whether changes in angular velocity would alter vastus lateralis (VL) and rectus femoris (RF) oxygenation status during maximal isokinetic knee extension exercises. Eleven recreationally active male participants randomly performed ten maximal knee extensions at 30, 60, 120 and 240° s(-1). Tissue oxygenation index (TOI) and total haemoglobin concentration ([tHb]) were acquired from the VL and RF muscles by means of near-infrared spectroscopy (NIRS). Breath-by-breath pulmonary oxygen consumption (VO(2p)) was recorded throughout the tests. Peak torque and VO(2p) significantly decreased as a function of velocity (P<0·05). Interestingly, RF and VL TOI significantly increased as a function of velocity (P<0·05), whereas [tHb] significantly decreased as a function of velocity (P<0·05). A greater number of muscle fibre recruited at slow velocity, where the torque and VO(2p) were the highest, might explain the lower VL and RF TOI observed herein. Furthermore, the increase in local blood flow (suggested by [tHb] changes) during isokinetic knee extension exercises performed at slow angular velocity might have been induced by a higher intramuscular pressure during the contraction phases as well as a greater microcirculatory vasodilatation during relaxation phases. Implementing slow-velocity isokinetic exercises in rehabilitation or other training programmes could delay the short-term anoxia generated by such exercises and result in muscle metabolism enhancement. © 2011 The Authors. Clinical Physiology and Functional Imaging © 2011 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  7. Isokinetic muscle performance of the hip and ankle muscles in women with fibromyalgia.

    PubMed

    Yetişgin, Alparslan; Tiftik, Tülay; Kara, Murat; Karabay, İlkay; Akkuş, Selami; Ersöz, Murat

    2016-06-01

    To compare isokinetic muscle performances of a proximal (hip) and a distal (ankle) muscle of fibromyalgia syndrome (FMS) patients with those of age- and body mass index (BMI)-matched healthy subjects. Thirty female patients with FMS (mean age: 41.5 ± 6.7 years [range, 27-54]) and 30 age- (mean age: 40.6 ± 6.0 years [range, 27-54]) and BMI-matched female healthy controls were consecutively enrolled. Demographic and clinical characteristics of the subjects were recorded. Isokinetic measurements of hip and ankle flexion and extension at angular velocities of 60°/s and 180°/s, peak torques, flexor-extensor torque ratios, muscle fatigue resistance values and average power were obtained. Mean disease duration of FMS patients was 2.4 ± 1.9 years. Mean weight, height and BMI values were 70.4 ± 12.5 kg, 159.5 ± 6.0 cm and 27.7 ± 4.7 kg/m² (FMS patients) and 69.3 ± 10.1 kg, 161.7 ± 6.2 cm and 26.6 ± 4.3 kg/m² (control subjects), respectively (all P > 0.05). All isokinetic values were statistically decreased in the FMS group when compared with the control group, except for the peak torques at angular velocity of 180°/s on flexion of the hip and extension of the ankle and the total work and average power on extension of the ankle. We did not find any correlation between isokinetic values and disease related parameters of FMS patients. In the light of our results, we may conclude that muscle strength and muscle fatigue seem to decrease in FMS patients' both proximal and distal lower extremity muscles. © 2013 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  8. Poor correlation between handgrip strength and isokinetic performance of knee flexor and extensor muscles in community-dwelling elderly women.

    PubMed

    Felicio, Diogo Carvalho; Pereira, Daniele Sirineu; Assumpção, Alexandra Miranda; de Jesus-Moraleida, Fabianna Resende; de Queiroz, Barbara Zille; da Silva, Juscelio Pereira; de Brito Rosa, Naysa Maciel; Dias, João Marcos Domingues; Pereira, Leani Souza Máximo

    2014-01-01

    To investigate the correlation between handgrip strength and performance of knee flexor and extensor muscles determined using an isokinetic dynamometer in community-dwelling elderly women. This was a cross-sectional study. Sample selection for the study was made by convenience, and 221 (71.07 ± 4.93 years) community-dwelling elderly women were included. Knee flexor and extensor muscle performance was measured using an isokinetic dynamometer Biodex System 3 Pro. The isokinetic variables chosen for analysis were peak torque, peak torque/bodyweight, total work/bodyweight, total work, average power, and agonist/antagonist ratio at the angular velocities of 60°/s and 180°/s. Assessment of handgrip strength was carried out using the Jamar dynamometer. Spearman's correlation coefficient was calculated to identify intervariable correlations. Only knee flexor peak torque (60°/s) and average power (60°/s), and knee extensor peak torque (180°/s) and total work (180°/s) were significantly (P < 0.05), yet poorly, correlated with handgrip strength (r < 0.30). The majority of analyses did not show any correlation between variables assessed by isokinetic dynamometer and handgrip dynamometer. Caution is required when generalizing handgrip strength as a predictor of global muscle strength in community-dwelling elderly women. © 2013 Japan Geriatrics Society.

  9. Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study.

    PubMed

    Kömürcü, Erkam; Yüksel, Halil Yalçın; Ersöz, Murat; Aktekin, Cem Nuri; Hapa, Onur; Çelebi, Levent; Akbal, Ayla; Biçimoğlu, Ali

    2014-12-01

    The aim of this study was to evaluate the effect of knee position during wound closure (flexed vs. extended) in total knee arthroplasty on knee strength and function, as determined by knee society scores and isokinetic testing of extensor and flexor muscle groups. In a prospective, randomized, double-blind trial, 29 patients were divided in two groups: for Group 1 patients, surgical closing was performed with the knee extended, and for Group 2 patients, the knee flexed at 90°. All the patients were treated with the same anaesthesia method, surgical team, surgical technique, prosthesis type, and rehabilitation process. American Knee Society Score values and knee flexion degrees were recorded. Isokinetic muscle strength measurements of both knees in flexion and extension were taken using 60° and 180°/s angular velocity. The peak torque and total work values, isokinetic muscle strength differences, and total work difference values were calculated for surgically repaired and healthy knees. No significant difference in the mean American Knee Society Score values and knee flexion degrees was observed between the two groups. However, using isokinetic evaluation, a significant difference was found in the isokinetic muscle strength differences and total work difference of the flexor muscle between the two groups when patients were tested at 180°/s. Less loss of strength was detected in the isokinetic muscle strength differences of the flexor muscle in Group 2 (-4.2%) than in Group 1 (-23.1%). For patients undergoing total knee arthroplasty, post-operative flexor muscle strength is improved if the knee is flexed during wound closure. II.

  10. In vivo maximal fascicle-shortening velocity during plantar flexion in humans.

    PubMed

    Hauraix, Hugo; Nordez, Antoine; Guilhem, Gaël; Rabita, Giuseppe; Dorel, Sylvain

    2015-12-01

    Interindividual variability in performance of fast movements is commonly explained by a difference in maximal muscle-shortening velocity due to differences in the proportion of fast-twitch fibers. To provide a better understanding of the capacity to generate fast motion, this study aimed to 1) measure for the first time in vivo the maximal fascicle-shortening velocity of human muscle; 2) evaluate the relationship between angular velocity and fascicle-shortening velocity from low to maximal angular velocities; and 3) investigate the influence of musculo-articular features (moment arm, tendinous tissues stiffness, and muscle architecture) on maximal angular velocity. Ultrafast ultrasound images of the gastrocnemius medialis were obtained from 31 participants during maximal isokinetic and light-loaded plantar flexions. A strong linear relationship between fascicle-shortening velocity and angular velocity was reported for all subjects (mean R(2) = 0.97). The maximal shortening velocity (V(Fmax)) obtained during the no-load condition (NLc) ranged between 18.8 and 43.3 cm/s. V(Fmax) values were very close to those of the maximal shortening velocity (V(max)), which was extrapolated from the F-V curve (the Hill model). Angular velocity reached during the NLc was significantly correlated with this V(Fmax) (r = 0.57; P < 0.001). This finding was in agreement with assumptions about the role of muscle fiber type, whereas interindividual comparisons clearly support the fact that other parameters may also contribute to performance during fast movements. Nevertheless, none of the biomechanical features considered in the present study were found to be directly related to the highest angular velocity, highlighting the complexity of the upstream mechanics that lead to maximal-velocity muscle contraction. Copyright © 2015 the American Physiological Society.

  11. Effects of the Competitive Season on the Isokinetic Muscle Parameters Changes in World-Class Handball Players.

    PubMed

    Maurelli, Olivier; Bernard, Pierre L; Dubois, Romain; Ahmaidi, Said; Prioux, Jacques

    2018-05-25

    Maurelli, O, Bernard, PL, Dubois, R, Ahmaidi, S, and Prioux, J. Effects of the competitive season on the isokinetic muscle parameters changes in world-class handball players. J Strength Cond Res XX(X): 000-000, 2018-The aim of this study is to investigate the effects of the competitive season on isokinetic muscular parameters of the lower limbs in world-class handball players. Nineteen, male, world-class, handball players (age, 26.6 ± 5.4 years) participated in the study. Two bilateral isokinetic tests of knee joint flexors (H; hamstring) and extensors (Q; quadriceps) were performed in the beginning and end of the competitive season to determine the peak torque (PT), the mean power, and agonist-antagonist ratio, dominant-nondominant ratio (DNDR), and combined ratio. The results showed a significant decrease in PT values at low angular velocity (60°·s) in concentric mode for Q on dominant leg (p < 0.001). The other PT values for dominant and nondominant legs at low and high angular velocities (240°·s) and in eccentric mode (30°·s) were not significantly different for Q and H. For mean power, values did not change at 60°·s. At 240°·s, we found a significant decrease in H for dominant leg (p < 0.001) but not for nondominant leg. In eccentric mode, the results showed a significant increase on both legs (p < 0.001). For the ratios, values significantly decreased for DNDR at 60°·s for Q (p < 0.03) and for agonist/antagonist ratio at 240°·s for the dominant leg (p < 0.01). The present results highlight the importance of integrating regular strength training sessions during the competitive season in world-class handball players. Accordingly, this study should help trainers to modify their planning to maximize strength and power qualities of the lower limbs of their players in addition to avoiding injuries.

  12. Effect of isokinetic training on strength, functionality and proprioception in athletes with functional ankle instability.

    PubMed

    Sekir, Ufuk; Yildiz, Yavuz; Hazneci, Bulent; Ors, Fatih; Aydin, Taner

    2007-05-01

    The purpose of this study was to investigate the effects of isokinetic exercise on strength, joint position sense and functionality in recreational athletes with functional ankle instability (FAI). Strength, proprioception and balance of 24 recreational athletes with unilateral FAI were evaluated by using isokinetic muscle strength measurement, ankle joint position sense and one leg standing test. The functional ability was evaluated using five different tests. These were; single limb hopping course (SLHC), one legged and triple legged hop for distance (OLHD-TLHD), and six and cross six meter hop for time (SMHT-CSMHT). Isokinetic peak torque of the ankle invertor and evertor muscles were assessed eccentrically and concentrically at test speeds of 120 degrees /s. Isokinetic exercise protocol was carried out at an angular velocity of 120 degrees /s. The exercise session was repeated three times a week and lasted after 6 weeks. At baseline, concentric invertor strength was found to be significantly lower in the functionally unstable ankles compared to the opposite healthy ankles (p < 0.001). This difference was not present after executing the 6 weeks exercise sessions (p > 0.05). Ankle joint position sense in the injured ankles declined significantly from 2.35 +/- 1.16 to 1.33 +/- 0.62 degrees for 10 degrees of inversion angle (p < 0.001) and from 3.10 +/- 2.16 to 2.19 +/- 0.98 degrees for 20 degrees of inversion angle (p < 0.05) following the isokinetic exercise. One leg standing test score decreased significantly from 15.17 +/- 8.50 to 11.79 +/- 7.81 in the injured ankles (p < 0.001). Following the isokinetic exercise protocol, all of the worsened functional test scores in the injured ankles as compared to the opposite healthy ankles displayed a significant improvement (p < 0.01 for OLHD and CSMHT, p < 0.001 for SLHC, TLHD, and SMHT). These results substantiate the deficits of strength, proprioception, balance and functionality in recreational athletes with FAI. The isokinetic exercise program used in this study had a positive effect on these parameters.

  13. Analysis of isokinetic muscle strength for sports physiotherapy research in Korean ssireum athletes

    PubMed Central

    Noh, Ji-Woong; Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of the present study was to elucidate the muscle conditions such as the isokinetic muscle of Korean ssireum athletes. [Subjects and Methods] This study enrolled 25 elite ssireum athletes. We measured body composition and peak torque at an angular speed at 60°/s using an isokinetic muscle strength dynamometer. [Results] The lean body mass of the left upper limb was significantly higher than that of the right upper limb. However, the lean body mass of the left lower limb was significantly lower than that of the right lower limb. The peak torque for left elbow flexion was significantly higher than that for right elbow flexion. Conversely, the peak torque for left elbow extension was significantly lower than that for right elbow extension. Furthermore, the peak torque for the left knee was significantly lower than that for the right knee for both flexion and extension. [Conclusion] The data from this study elucidate in part the muscle conditions of Korean ssireum athletes, which can be used to establish a reference for the scientific study of sports physiotherapy. PMID:26644679

  14. Analysis of isokinetic muscle strength for sports physiotherapy research in Korean ssireum athletes.

    PubMed

    Noh, Ji-Woong; Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-10-01

    [Purpose] The purpose of the present study was to elucidate the muscle conditions such as the isokinetic muscle of Korean ssireum athletes. [Subjects and Methods] This study enrolled 25 elite ssireum athletes. We measured body composition and peak torque at an angular speed at 60°/s using an isokinetic muscle strength dynamometer. [Results] The lean body mass of the left upper limb was significantly higher than that of the right upper limb. However, the lean body mass of the left lower limb was significantly lower than that of the right lower limb. The peak torque for left elbow flexion was significantly higher than that for right elbow flexion. Conversely, the peak torque for left elbow extension was significantly lower than that for right elbow extension. Furthermore, the peak torque for the left knee was significantly lower than that for the right knee for both flexion and extension. [Conclusion] The data from this study elucidate in part the muscle conditions of Korean ssireum athletes, which can be used to establish a reference for the scientific study of sports physiotherapy.

  15. [Correlation of age, IGF-1 serum levels, muscular mass index and their influence as determinants of isokinetic variables in patients with osteoporosis].

    PubMed

    Coronado-Zarco, Roberto; Diez-García, María del Pilar; Chávez-Arias, Daniel; León-Hernández, Saúl Renán; Cruz-Medina, Eva; Arellano-Hernández, Aurelia

    2005-01-01

    Bone and skeletal muscle mass loss is related to age. Mechanisms by which they interact have not been well established. To establish a relationship of age with serum levels of IGF-1, skeletal muscle and appendicular muscle mass index, and their influence in isokinetic parameters in osteoporotic female patients. Pearson correlation coefficient and linear regression analyses were used. There were 38 patients with a mean age of 65.16 years (range: 50-84 years), mean appendicular skeletal mass index (ASMI) of 6.3 kg/m2 (range: 4.3-8.3) and mean skeletal mass index (SMI) of 12.4 kg/m2 (range: 9.6-15.7), mean serum IGF-1 levels of 82.97 ng/ml (range: 22-177). Linear regression predicted hip mineral bone density by SMI (p = 0.19) and age (p = 0.017, r = 0.50). Some isokinetic parameters had a positive correlation for work with age. Knee acceleration time had a positive correlation with age. Osteoporosis and sarcopenia may have related pathophysiologic mechanisms. Growth factor study must include the influence of sex hormones. Some isokinetic parameters are determined by the predominant muscle fiber, skeletal mass index and age.

  16. Potentiation and recovery following low- and high-speed isokinetic contractions in boys.

    PubMed

    Chaouachi, Anis; Haddad, Monoem; Castagna, Carlo; Wong, Del P; Kaouech, Fathi; Chamari, Karim; Behm, David G

    2011-02-01

    The objective of this study was to examine the response and recovery to a single set of maximal, low and high angular velocity isokinetic leg extension-flexion contractions with boys. Sixteen boys (11-14 yrs) performed 10 isokinetic contractions at 60°.s-1 (Isok60) and 300°.s-1 (Isok300). Three contractions at both velocities, blood lactate and ratings of perceived exertion were monitored pretest and at 2, 3, 4, and 5 min of recovery (RI). Participants were tested in a random counterbalanced order for each velocity and recovery period. Only a single contraction velocity (300°.s-1 or 60°.s-1) was tested during recovery at each session to remove confounding influences between the recovery intervals. Recovery results showed no change in quadriceps' power at 300°.s-1, quadriceps' power, work and torque at 60°.s-1 and hamstrings' power and work with 60°.s-1. There was an increase during the 2 min RI in hamstrings' power, work and torque and quadriceps' torque with isokinetic contractions at 300°.s-1 suggesting a potentiating effect. Performance impairments during recovery occurred for the hamstrings torque at 60°.s-1 and quadriceps work with 300°.s-1. In conclusion, 10 repetitions of either low or high velocity isokinetic contractions (Isok60 or Isok300) resulted in full recovery or potentiation of most measures within 2 min in boys. The potentiation effect predominantly occurred following the hamstrings Isok300 which might be attributed to a greater agonist-antagonist torque balance and less metabolic stress associated with the shorter duration higher velocity contractions.

  17. Coactivation of the elbow antagonist muscles is not affected by the speed of movement in isokinetic exercise.

    PubMed

    Bazzucchi, Ilenia; Sbriccoli, Paola; Marzattinocci, Giulia; Felici, Francesco

    2006-02-01

    Since muscle coactivation increases the stiffness and stability of a joint, greater coactivation is likely during faster than slower movements. Very few studies, though, have been conducted to verify this hypothesis. Moreover, a large number of studies have examined coactivation of muscles surrounding the knee joint whereas there are few reports on the elbow joint. The aim of this study was therefore to compare the antagonist activation of the elbow flexors and extensors during isokinetic concentric exercises and to investigate the influence of angular velocity on their activation. Twelve men participated in the study. The surface electromyographic signals (sEMG) were recorded from the biceps brachii (BB) and triceps brachii (TB) muscles during three maximal voluntary isometric contractions (MVC) of elbow flexors and extensors and a set of three maximal elbow flexions and extensions each at 15 degrees, 30 degrees , 60 degrees, 120 degrees, 180 degrees, and 240 degrees.s(-1). Normalized root mean square (RMS) of sEMG was calculated during the isokinetic phase of movement as an index of sEMG amplitude. During elbow flexion, the antagonist activation of BB averaged 16.2% lower than TB, and this difference was statistically significant at all angular velocities. The normalized RMS values ranged from 26.0% +/- 19.0 at MVC to 37.8% +/- 13.9 at 240 degrees.s(-1) for antagonist TB activation, and from 5.7% +/- 5.2 at MVC to 18.9% +/- 8.6 at 240 degrees.s(-1) for antagonist BB activation. No influence of angular velocity on agonist and antagonist activity was found. Moreover, flexion and extension torques were both strongly affected by the amount of antagonist activation. The functional specialization of the two muscle groups could be responsible for the different levels of antagonist activation. The frequent use of BB, which is not assisted by gravity during daily activities, could lead to reduced coactivation due to a better functioning of the control system based upon reciprocal innervation. These findings may have significant implications in the design of rehabilitation programs directed to the elbow joint.

  18. Self-reported knee joint instability is related to passive mechanical stiffness in medial knee osteoarthritis.

    PubMed

    Creaby, Mark W; Wrigley, Tim V; Lim, Boon-Whatt; Hinman, Rana S; Bryant, Adam L; Bennell, Kim L

    2013-11-20

    Self-reported knee joint instability compromises function in individuals with medial knee osteoarthritis and may be related to impaired joint mechanics. The purpose of this study was to evaluate the relationship between self-reported instability and the passive varus-valgus mechanical behaviour of the medial osteoarthritis knee. Passive varus-valgus angular laxity and stiffness were assessed using a modified isokinetic dynamometer in 73 participants with medial tibiofemoral osteoarthritis. All participants self-reported the absence or presence of knee instability symptoms and the degree to which instability affected daily activity on a 6-point likert scale. Forward linear regression modelling identified a significant inverse relationship between passive mid-range knee stiffness and symptoms of knee instability (r = 0.27; P < 0.05): reduced stiffness was indicative of more severe instability symptoms. Angular laxity and end-range stiffness were not related to instability symptoms (P > 0.05). Conceivably, a stiffer passive system may contribute toward greater joint stability during functional activities. Importantly however, net joint stiffness is influenced by both active and passive stiffness, and thus the active neuromuscular system may compensate for reduced passive stiffness in order to maintain joint stability. Future work is merited to examine the role of active stiffness in symptomatic joint stability.

  19. Self-reported knee joint instability is related to passive mechanical stiffness in medial knee osteoarthritis

    PubMed Central

    2013-01-01

    Background Self-reported knee joint instability compromises function in individuals with medial knee osteoarthritis and may be related to impaired joint mechanics. The purpose of this study was to evaluate the relationship between self-reported instability and the passive varus-valgus mechanical behaviour of the medial osteoarthritis knee. Methods Passive varus-valgus angular laxity and stiffness were assessed using a modified isokinetic dynamometer in 73 participants with medial tibiofemoral osteoarthritis. All participants self-reported the absence or presence of knee instability symptoms and the degree to which instability affected daily activity on a 6-point likert scale. Results Forward linear regression modelling identified a significant inverse relationship between passive mid-range knee stiffness and symptoms of knee instability (r = 0.27; P < 0.05): reduced stiffness was indicative of more severe instability symptoms. Angular laxity and end-range stiffness were not related to instability symptoms (P > 0.05). Conclusions Conceivably, a stiffer passive system may contribute toward greater joint stability during functional activities. Importantly however, net joint stiffness is influenced by both active and passive stiffness, and thus the active neuromuscular system may compensate for reduced passive stiffness in order to maintain joint stability. Future work is merited to examine the role of active stiffness in symptomatic joint stability. PMID:24252592

  20. The Effects of Multiple-Joint Isokinetic Resistance Training on Maximal Isokinetic and Dynamic Muscle Strength and Local Muscular Endurance.

    PubMed

    Ratamess, Nicholas A; Beller, Noah A; Gonzalez, Adam M; Spatz, Gregory E; Hoffman, Jay R; Ross, Ryan E; Faigenbaum, Avery D; Kang, Jie

    2016-03-01

    The transfer of training effects of multiple-joint isokinetic resistance training to dynamic exercise performance remain poorly understood. Thus, the purpose of the present study was to investigate the magnitude of isokinetic and dynamic one repetition-maximum (1RM) strength and local muscular endurance increases after 6 weeks of multiple-joint isokinetic resistance training. Seventeen women were randomly assigned to either an isokinetic resistance training group (IRT) or a non-exercising control group (CTL). The IRT group underwent 6 weeks of training (2 days per week) consisting of 5 sets of 6-10 repetitions at 75-85% of subjects' peak strength for the isokinetic chest press and seated row exercises at an average linear velocity of 0.15 m s(-1) [3-sec concentric (CON) and 3-sec eccentric (ECC) phases]. Peak CON and ECC force during the chest press and row, 1RM bench press and bent-over row, and maximum number of modified push-ups were assessed pre and post training. A 2 x 2 analysis of variance with repeated measures and Tukey's post hoc tests were used for data analysis. The results showed that 1RM bench press (from 38.6 ± 6.7 to 43.0 ± 5.9 kg), 1RM bent-over row (from 40.4 ± 7.7 to 45.5 ± 7.5 kg), and the maximal number of modified push-ups (from 39.5 ± 13.6 to 55.3 ± 13.1 repetitions) increased significantly only in the IRT group. Peak isokinetic CON and ECC force in the chest press and row significantly increased in the IRT group. No differences were shown in the CTL group for any measure. These data indicate 6 weeks of multiple-joint isokinetic resistance training increases dynamic muscle strength and local muscular endurance performance in addition to specific isokinetic strength gains in women. Key pointsMultiple-joint isokinetic resistance training increases dynamic maximal muscular strength, local muscular endurance, and maximal isokinetic strength in women.Multiple-joint isokinetic resistance training increased 1RM strength in the bench press (by 10.2%), bent-over barbell row (by 11.2%), and maximal modified push-up performance (by 28.6%) indicating a carryover of training effects to dynamic exercise performance.The carryover effects may be attractive to strength training and conditioning professionals seeking to include alternative modalities such as multiple-joint isokinetic dynamometers to resistance training programs.

  1. The Effects of Multiple-Joint Isokinetic Resistance Training on Maximal Isokinetic and Dynamic Muscle Strength and Local Muscular Endurance

    PubMed Central

    Ratamess, Nicholas A.; Beller, Noah A.; Gonzalez, Adam M.; Spatz, Gregory E.; Hoffman, Jay R.; Ross, Ryan E.; Faigenbaum, Avery D.; Kang, Jie

    2016-01-01

    The transfer of training effects of multiple-joint isokinetic resistance training to dynamic exercise performance remain poorly understood. Thus, the purpose of the present study was to investigate the magnitude of isokinetic and dynamic one repetition-maximum (1RM) strength and local muscular endurance increases after 6 weeks of multiple-joint isokinetic resistance training. Seventeen women were randomly assigned to either an isokinetic resistance training group (IRT) or a non-exercising control group (CTL). The IRT group underwent 6 weeks of training (2 days per week) consisting of 5 sets of 6-10 repetitions at 75-85% of subjects’ peak strength for the isokinetic chest press and seated row exercises at an average linear velocity of 0.15 m s-1 [3-sec concentric (CON) and 3-sec eccentric (ECC) phases]. Peak CON and ECC force during the chest press and row, 1RM bench press and bent-over row, and maximum number of modified push-ups were assessed pre and post training. A 2 x 2 analysis of variance with repeated measures and Tukey’s post hoc tests were used for data analysis. The results showed that 1RM bench press (from 38.6 ± 6.7 to 43.0 ± 5.9 kg), 1RM bent-over row (from 40.4 ± 7.7 to 45.5 ± 7.5 kg), and the maximal number of modified push-ups (from 39.5 ± 13.6 to 55.3 ± 13.1 repetitions) increased significantly only in the IRT group. Peak isokinetic CON and ECC force in the chest press and row significantly increased in the IRT group. No differences were shown in the CTL group for any measure. These data indicate 6 weeks of multiple-joint isokinetic resistance training increases dynamic muscle strength and local muscular endurance performance in addition to specific isokinetic strength gains in women. Key points Multiple-joint isokinetic resistance training increases dynamic maximal muscular strength, local muscular endurance, and maximal isokinetic strength in women. Multiple-joint isokinetic resistance training increased 1RM strength in the bench press (by 10.2%), bent-over barbell row (by 11.2%), and maximal modified push-up performance (by 28.6%) indicating a carryover of training effects to dynamic exercise performance. The carryover effects may be attractive to strength training and conditioning professionals seeking to include alternative modalities such as multiple-joint isokinetic dynamometers to resistance training programs. PMID:26957924

  2. The effect of the training with the different combinations of frequency and peak-to-peak vibration displacement of whole-body vibration on the strength of knee flexors and extensors

    PubMed Central

    Król, P; Sobota, G; Polak, A; Bacik, B; Juras, G

    2017-01-01

    Whole-body vibration training has become a popular method used in sports and physiotherapy. The study aimed to evaluate the effect of different vibration frequency and peak-to-peak displacement combinations on men knee flexors and extensors strength in isokinetic conditions. The sample consisted of 49 male subjects randomly allocated to seven comparative groups, six of which exercised on a vibration platform with parameters set individually for the groups. The experimental groups were exposed to vibrations 3 times a week for 4 weeks. The pre- and post- isokinetic strength tests, with the angular velocities of 240°/s and 30°/s, were recorded prior to and 2 days after the training. After 4 weeks of whole-body vibration training, a significant increase was noted regarding the mean values of peak torque, average peak torque and total work for knee flexors at high angular velocity in Groups I (60 Hz/4 mm) and V (40 Hz/2 mm) (p<0.05). The mean percentage values of post-training changes to study parameters suggest that the training had the most beneficial effect in Groups I (60 Hz/4 mm) and IV (60 Hz/2 mm) (p<0.05). Whole-body vibrations during static exercise beneficially affected knee flexor strength profile in young men at high angular velocity. The combinations of 60 Hz/4 mm seem to have the most advantageous effects on muscle strength parameters. PMID:28566806

  3. Isokinetic peak torque and flexibility changes of the hamstring muscles after eccentric training: Trained versus untrained subjects.

    PubMed

    Abdel-Aziem, Amr Almaz; Soliman, Elsadat Saad; Abdelraouf, Osama Ragaa

    2018-05-23

    The aim of this study was to examine the effect of eccentric isotonic training on hamstring flexibility and eccentric and concentric isokinetic peak torque in trained and untrained subjects. Sixty healthy subjects (mean age: 21.66 ± 2.64) were divided into three equal groups, each with 20 voluntary participants. Two experimental groups (untrained and trained groups) participated in a hamstring eccentric isotonic strengthening program (five days/week) for a six-week period and one control group that was not involved in the training program. The passive knee extension range of motion and hamstring eccentric and concentric isokinetic peak torque were measured at angular velocities 60° and 120°/s for all groups before and after the training period. Two-way analysis of variance showed that there was a significant increase in the hamstring flexibility of the untrained and trained groups (25.65 ± 6.32°, 26.55 ± 5.99°, respectively), (p < 0.05) without a significant increase in the control group (31.55 ± 5.84°), (p > 0.05). Moreover, there was a significant increase in eccentric isokinetic peak torque of both the untrained and trained groups (127.25 ± 22.60Nm, 139.65 ± 19.15Nm, 125.40 ± 21.61Nm, 130.90 ± 18.71Nm, respectively), (p < 0.05) without a significant increase in the control group (109.15 ± 20.89Nm, 105.70 ± 21.31Nm, respectively), (p > 0.05) at both angular velocities. On the other hand, there was no significant increase in the concentric isokinetic peak torque of the three groups (92.50 ± 20.50Nm, 79.05 ± 18.95Nm, 92.20 ± 21.96Nm, 79.85 ± 18.97Nm, 100.45 ± 25.78Nm, 83.40 ± 23.73Nm, respectively), (p > 0.05) at both angular velocities. The change scores in the hamstring flexibility (06.25 ± 1.86°) and eccentric peak torque of the untrained group (16.60 ± 4.81Nm, 17.45 ± 5.40Nm, respectively) were significantly higher (p < 0.05) than those of the trained group (03.40 ± 1.14°, 9.90 ± 5.14Nm, 9.80 ± 7.57Nm, respectively), and the control group (00.90 ± 2.10°, 0.60 ± 2.93Nm, 1.40 ± 3.53Nm, respectively), at both angular velocities. Meanwhile, the change scores of the concentric peak torques of the three groups (1.15 ± 1.50Nm, -0.15 ± 2.16Nm, 1.35 ± 1.63Nm, 0.20 ± 2.95Nm, 0.60 ± 2.28Nm, -0.30 ± 2.25Nm) were statistically insignificant (p > 0.05). After a six-week period of eccentric isotonic training, the hamstring eccentric peak torque and flexibility of trained and untrained groups improved without changes in the concentric peak torque. Moreover, the improvement of untrained subjects was higher than trained subjects. These findings may be helpful in designing the hamstring rehabilitation program. Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  4. Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity

    PubMed Central

    Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.

    2015-01-01

    Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381

  5. Effects of Static and Dynamic Stretching on the Isokinetic Peak Torques and Electromyographic Activities of the Antagonist Muscles.

    PubMed

    Serefoglu, Abdullah; Sekir, Ufuk; Gür, Hakan; Akova, Bedrettin

    2017-03-01

    The aim of this study was to investigate if static and dynamic stretching exercises of the knee muscles (quadriceps and hamstring muscles) have any effects on concentric and eccentric isokinetic peak torques and electromyographic amplitudes (EMG) of the antagonist muscles. Twenty healthy male athletes (age between 18-30 years) voluntarily participated in this study. All of the subjects visited the laboratory to complete the following intervention in a randomized order on 5 separate days; (a) non-stretching (control), (b) static stretching of the quadriceps muscles, (c) static stretching of the hamstring muscles, (d) dynamic stretching of the quadriceps muscles, and (e) dynamic stretching of the hamstring muscles. Static stretching exercises either for the quadriceps or the hamstring muscles were carried out at the standing and sitting positions. Subjects performed four successive repetitions of each stretching exercises for 30 seconds in both stretching positions. Similar to static stretching exercises two different stretching modes were designed for dynamic stretching exercises. Concentric and eccentric isokinetic peak torque for the non-stretched antagonist quadriceps or hamstring muscles at angular velocities of 60°/sec and 240°/sec and their concurrent electromyographic (EMG) activities were measured before and immediately after the intervention. Isokinetic peak torques of the non-stretched agonist hamstring and quadriceps muscles did not represent any significant (p > 0.05) differences following static and dynamic stretching of the antagonist quadriceps and hamstring muscles, respectively. Similarly, the EMG activities of the agonist muscles exhibited no significant alterations (p > 0.05) following both stretching exercises of the antagonist muscles. According to the results of the present study it is possible to state that antagonist stretching exercises either in the static or dynamic modes do not affect the isokinetic peak torques and the EMG activities of the non-stretched agonist quadriceps or hamstring muscles.

  6. Isokinetic strength assessment offers limited predictive validity for detecting risk of future hamstring strain in sport: a systematic review and meta-analysis.

    PubMed

    Green, Brady; Bourne, Matthew N; Pizzari, Tania

    2018-03-01

    To examine the value of isokinetic strength assessment for predicting risk of hamstring strain injury, and to direct future research into hamstring strain injuries. Systematic review. Database searches for Medline, CINAHL, Embase, AMED, AUSPORT, SPORTDiscus, PEDro and Cochrane Library from inception to April 2017. Manual reference checks, ahead-of-press and citation tracking. Prospective studies evaluating isokinetic hamstrings, quadriceps and hip extensor strength testing as a risk factor for occurrence of hamstring muscle strain. Independent search result screening. Risk of bias assessment by independent reviewers using Quality in Prognosis Studies tool. Best evidence synthesis and meta-analyses of standardised mean difference (SMD). Twelve studies were included, capturing 508 hamstring strain injuries in 2912 athletes. Isokinetic knee flexor, knee extensor and hip extensor outputs were examined at angular velocities ranging 30-300°/s, concentric or eccentric, and relative (Nm/kg) or absolute (Nm) measures. Strength ratios ranged between 30°/s and 300°/s. Meta-analyses revealed a small, significant predictive effect for absolute (SMD=-0.16, P=0.04, 95% CI -0.31 to -0.01) and relative (SMD=-0.17, P=0.03, 95% CI -0.33 to -0.014) eccentric knee flexor strength (60°/s). No other testing speed or strength ratio showed statistical association. Best evidence synthesis found over half of all variables had moderate or strong evidence for no association with future hamstring injury. Despite an isolated finding for eccentric knee flexor strength at slow speeds, the role and application of isokinetic assessment for predicting hamstring strain risk should be reconsidered, particularly given costs and specialised training required. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Intramuscular pressure and electromyography as indexes of force during isokinetic exercise

    NASA Technical Reports Server (NTRS)

    Aratow, M.; Ballard, R. E.; Grenshaw, A. G.; Styf, J.; Watenpaugh, D. E.; Kahan, N. J.; Hargens, A. R.

    1993-01-01

    A direct method for measuring force production of specific muscles during dynamic exercise is presently unavailable. Previous studies indicate that both intramuscular pressure (IMP) and electromyography (EMG) correlate linearly with muscle contraction force during isometric exercise. The objective of this study was to compare IMP and EMG as linear assessors of muscle contraction force during dynamic exercise. IMP and surface EMG activity were recorded during concentric and eccentric isokinetic plantarflexion and dorsiflexion of the ankle joint from the tibialis anterior (TA) and soleus (SOL) muscles of nine male volunteers. Ankle torque was measured using a dynamometer, and IMP was measured via catheterization. IMP exhibited better linear correlation than EMG with ankle joint torque during concentric contractions of the SOL and the TA, as well as during eccentric contractions. IMP provides a better index of muscle contraction force than EMG during concentric and eccentric exercise through the entire range of torque. IMP reflects intrinsic mechanical properties of individual muscles, such as length-tension relationships, which EMG is unable to assess.

  8. Linear and angular control of circular walking in healthy older adults and subjects with cerebellar ataxia.

    PubMed

    Goodworth, Adam D; Paquette, Caroline; Jones, Geoffrey Melvill; Block, Edward W; Fletcher, William A; Hu, Bin; Horak, Fay B

    2012-05-01

    Linear and angular control of trunk and leg motion during curvilinear navigation was investigated in subjects with cerebellar ataxia and age-matched control subjects. Subjects walked with eyes open around a 1.2-m circle. The relationship of linear to angular motion was quantified by determining the ratios of trunk linear velocity to trunk angular velocity and foot linear position to foot angular position. Errors in walking radius (the ratio of linear to angular motion) also were quantified continuously during the circular walk. Relative variability of linear and angular measures was compared using coefficients of variation (CoV). Patterns of variability were compared using power spectral analysis for the trunk and auto-covariance analysis for the feet. Errors in radius were significantly increased in patients with cerebellar damage as compared to controls. Cerebellar subjects had significantly larger CoV of feet and trunk in angular, but not linear, motion. Control subjects also showed larger CoV in angular compared to linear motion of the feet and trunk. Angular and linear components of stepping differed in that angular, but not linear, foot placement had a negative correlation from one stride to the next. Thus, walking in a circle was associated with more, and a different type of, variability in angular compared to linear motion. Results are consistent with increased difficulty of, and role of the cerebellum in, control of angular trunk and foot motion for curvilinear locomotion.

  9. The feasibility of measuring joint angular velocity with a gyro-sensor.

    PubMed

    Arai, Takeshi; Obuchi, Shuichi; Shiba, Yoshitaka; Omuro, Kazuya; Nakano, Chika; Higashi, Takuya

    2008-01-01

    To determine the reliability of an assessment of joint angular velocity using a gyro-sensor and to examine the relationship between ankle angular velocity and physical functions. Cross-sectional. Kinesiology laboratory. Twenty healthy young adults (mean age, 22.5 y) and 113 community-dwelling older adults (mean age, 75.1 y). Not applicable. Maximal ankle joint velocity was measured using a gyro-sensor during heel-rising and jumping with knee extended. The intraclass correlation coefficient (ICC) was used to determine the intertester and intratester reliability. The Pearson correlation coefficient was used to examine the relationships between maximal ankle joint velocity and isometric muscle strength and isokinetic muscle power in young adults and also to examine the relationships between maximal ankle joint velocity and functional performance measurements such as walking time in older adults. High reliability was found for intertester (ICC=.96) and intratester reliability (ICC=.96). The data from the gyro-sensor highly correlated with muscle strength (r range, .62-.68; P<.01) and muscle power (r range, .45-.79; P range, .01-.05). In older subjects, mobility functions significantly correlated with the angular velocity of ankle plantarflexion. Measurement of ankle angular velocity using a gyro-sensor is both reliable and feasible, with the results representing a significant correlation to muscle power and performance measurements.

  10. Experimental knee joint pain during strength training and muscle strength gain in healthy subjects: a randomized controlled trial.

    PubMed

    Sørensen, T J; Langberg, H; Hodges, P W; Bliddal, H; Henriksen, M

    2012-01-01

    Knee joint pain and reduced quadriceps strength are cardinal symptoms in many knee pathologies. In people with painful knee pathologies, quadriceps exercise reduces pain, improves physical function, and increases muscle strength. A general assumption is that pain compromises muscle function and thus may prevent effective rehabilitation. This study evaluated the effects of experimental knee joint pain during quadriceps strength training on muscle strength gain in healthy individuals. Twenty-seven healthy untrained volunteers participated in a randomized controlled trial of quadriceps strengthening (3 times per week for 8 weeks). Participants were randomized to perform resistance training either during pain induced by injections of painful hypertonic saline (pain group, n = 13) or during a nonpainful control condition with injection of isotonic saline (control group, n = 14) into the infrapatellar fat pad. The primary outcome measure was change in maximal isokinetic muscle strength in knee extension/flexion (60, 120, and 180 degrees/second). The group who exercised with pain had a significantly larger improvement in isokinetic muscle strength at all angular velocities of knee extension compared to the control group. In knee flexion there were improvements in isokinetic muscle strength in both groups with no between-group differences. Experimental knee joint pain improved the training-induced gain in muscle strength following 8 weeks of quadriceps training. It remains to be studied whether knee joint pain has a positive effect on strength gain in patients with knee pathology. Copyright © 2012 by the American College of Rheumatology.

  11. Isokinetic Strength Profile of Elite Female Handball Players.

    PubMed

    Xaverova, Zuzana; Dirnberger, Johannes; Lehnert, Michal; Belka, Jan; Wagner, Herbert; Orechovska, Karolina

    2015-12-22

    Systematic assessment of muscle strength of the lower extremities throughout the annual training cycle in athletes is crucial from a performance perspective for the optimization of the training process, as well as a health perspective with regard to injury prevention. The main aim of the present study was to determine isokinetic muscle strength of the knee flexors and extensors in female handball players at the beginning of a preparatory period and to assess whether there were any differences between players of different performance levels. The performance level was expressed by means of membership of the Women's Junior National Handball Team (JNT, n=8) or the Women's National Handball Team (NT, n=9). The isokinetic peak torque during concentric and eccentric single-joint knee flexion and extension was measured at angular velocities of 60, 180, 240°/s (concentric) and 60°/s (eccentric). The Mann-Whitney test showed no significant differences in the peak torques or ipsilateral ratios between the two groups. The bilateral force deficit (BFD) for concentric extension at 240°/s was significantly higher in the JNT compared with the NT (p=0.04; d=1.02). However, the results of individual evaluation show that the BFD was more frequent in the NT in most measurements. A high BFD was evident in the eccentric mode in both groups highlighting a need for particular strengthening. With regard to low strength ratios a prevention programme should be suggested for both observed groups of professional female handball players to reduce the risk of injury.

  12. Muscle Strength Imbalance in the Hip Joint Caused by Fast Movements

    NASA Astrophysics Data System (ADS)

    Pontaga, I.

    2003-07-01

    Eleven male sportsmen at the age of 24.3 ± 4.5 were examined. Their hip joint flexors and extensors were tested by an "REV-9000" Technogym dynamometer system during isokinetic movements at angular velocities of 100 (low) and 200 (high) °/s. The range of hip joint movements was from 30 (in flexion) to 130° (in extension). Torque values and their ratios for hip flexors and extensors at different angular positions were obtained and compared. It is shown that, at high speeds, the flexion movement significantly raises ( p < 0.001) the torque ratios of flexors and extensors in flexion positions of the hip (50 and 60°). These ratios approximately twofold exceed their values at moderate velocities. The weakness of hip joint extensors in extreme flexion positions of the hip may cause injury of this group of muscles at fast movements.

  13. Effects of Static and Dynamic Stretching on the Isokinetic Peak Torques and Electromyographic Activities of the Antagonist Muscles

    PubMed Central

    Serefoglu, Abdullah; Sekir, Ufuk; Gür, Hakan; Akova, Bedrettin

    2017-01-01

    The aim of this study was to investigate if static and dynamic stretching exercises of the knee muscles (quadriceps and hamstring muscles) have any effects on concentric and eccentric isokinetic peak torques and electromyographic amplitudes (EMG) of the antagonist muscles. Twenty healthy male athletes (age between 18-30 years) voluntarily participated in this study. All of the subjects visited the laboratory to complete the following intervention in a randomized order on 5 separate days; (a) non-stretching (control), (b) static stretching of the quadriceps muscles, (c) static stretching of the hamstring muscles, (d) dynamic stretching of the quadriceps muscles, and (e) dynamic stretching of the hamstring muscles. Static stretching exercises either for the quadriceps or the hamstring muscles were carried out at the standing and sitting positions. Subjects performed four successive repetitions of each stretching exercises for 30 seconds in both stretching positions. Similar to static stretching exercises two different stretching modes were designed for dynamic stretching exercises. Concentric and eccentric isokinetic peak torque for the non-stretched antagonist quadriceps or hamstring muscles at angular velocities of 60°/sec and 240°/sec and their concurrent electromyographic (EMG) activities were measured before and immediately after the intervention. Isokinetic peak torques of the non-stretched agonist hamstring and quadriceps muscles did not represent any significant (p > 0.05) differences following static and dynamic stretching of the antagonist quadriceps and hamstring muscles, respectively. Similarly, the EMG activities of the agonist muscles exhibited no significant alterations (p > 0.05) following both stretching exercises of the antagonist muscles. According to the results of the present study it is possible to state that antagonist stretching exercises either in the static or dynamic modes do not affect the isokinetic peak torques and the EMG activities of the non-stretched agonist quadriceps or hamstring muscles. Key points The effects of dynamic stretching of the antagonist muscles on strength performance are unknown. We showed that both static and dynamic stretching of the antagonist muscle does not influence strength and EMG activities in the agonist muscles. Further research should focus on the effects of antagonist stretching using other techniques like PNF or ballistic stretching and/or different volumes of stretching. PMID:28344445

  14. Isokinetic Strength Profile of Elite Female Handball Players

    PubMed Central

    Xaverova, Zuzana; Dirnberger, Johannes; Lehnert, Michal; Belka, Jan; Wagner, Herbert; Orechovska, Karolina

    2015-01-01

    Systematic assessment of muscle strength of the lower extremities throughout the annual training cycle in athletes is crucial from a performance perspective for the optimization of the training process, as well as a health perspective with regard to injury prevention. The main aim of the present study was to determine isokinetic muscle strength of the knee flexors and extensors in female handball players at the beginning of a preparatory period and to assess whether there were any differences between players of different performance levels. The performance level was expressed by means of membership of the Women’s Junior National Handball Team (JNT, n=8) or the Women’s National Handball Team (NT, n=9). The isokinetic peak torque during concentric and eccentric single-joint knee flexion and extension was measured at angular velocities of 60, 180, 240°/s (concentric) and 60°/s (eccentric). The Mann-Whitney test showed no significant differences in the peak torques or ipsilateral ratios between the two groups. The bilateral force deficit (BFD) for concentric extension at 240°/s was significantly higher in the JNT compared with the NT (p=0.04; d=1.02). However, the results of individual evaluation show that the BFD was more frequent in the NT in most measurements. A high BFD was evident in the eccentric mode in both groups highlighting a need for particular strengthening. With regard to low strength ratios a prevention programme should be suggested for both observed groups of professional female handball players to reduce the risk of injury. PMID:26839626

  15. Isokinetic Identification of Knee Joint Torques before and after Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Czaplicki, Adam; Jarocka, Marta; Walawski, Jacek

    2015-01-01

    The aim of this study was to evaluate the serial change of isokinetic muscle strength of the knees before and after anterior cruciate ligament reconstruction (ACLR) in physically active males and to estimate the time of return to full physical fitness. Extension and flexion torques were measured for the injured and healthy limbs at two angular velocities approximately 1.5 months before the surgery and 3, 6, and 12 months after ACLR. Significant differences (p ≤ 0.05) in peak knee extension and flexion torques, hamstring/quadriceps (H/Q) strength ratios, uninvolved/involved limb peak torque ratios, and the normalized work of these muscles between the four stages of rehabilitation were identified. Significant differences between extension peak torques for the injured and healthy limbs were also detected at all stages. The obtained results showed that 12 months of rehabilitation were insufficient for the involved knee joint to recover its strength to the level of strength of the uninvolved knee joint. The results helped to evaluate the progress of the rehabilitation and to implement necessary modifications optimizing the rehabilitation training program. The results of the study may also be used as referential data for physically active males of similar age. PMID:26646385

  16. Explosive Strength Imbalances in Professional Basketball Players

    PubMed Central

    Schiltz, Marc; Lehance, Cédric; Maquet, Didier; Bury, Thierry; Crielaard, Jean-Michel; Croisier, Jean-Louis

    2009-01-01

    Context: Despite the high rate of lower limb injuries in basketball players, studies of the dominant-limb effect in elite athletes often neglect injury history. Objective: To determine lower limb explosive-strength asymmetries in professional basketball players compared with junior basketball players and control participants. Design: Cohort study. Setting: Academic medical institution. Patients or Other Participants: 15 professional basketball players, 10 junior basketball players, and 20 healthy men. Main Outcome Measure(s): We performed an isokinetic examination to evaluate the knee extensor (Ext) and flexor (Fl) concentric peak torque at 60°·s−1 and 240°·s−1 and (Fl only) eccentric peak torque at 30°·s−1 and 120°·s−1. Functional evaluation included countermovement jump, countermovement jump with arms, 10-m sprint, single-leg drop jump, and single-leg, 10-second continuous jumping. Variables were compared among groups using analysis of variance or a generalized linear mixed model for bilateral variables. Results: The 2 groups of basketball players demonstrated better isokinetic and functional performances than the control group did. No differences in functional or relative isokinetic variables were noted between professional and junior basketball players. Professional players with a history of knee injury failed to reach normal knee extensor strength at 60°·s−1. Knee Ext (60°·s−1) and Fl (eccentric 120°·s−1) torque values as well as 10-second continuous jumping scores were higher in those professional players without a history of knee injury than those with such a history. Compared with the group without a history of knee injury, the group with a history of knee injury maintained leg asymmetry ratios greater than 10% for almost all isokinetic variables and more than 15% for unilateral functional variables. Conclusions: The relative isokinetic and functional performances of professional basketball players were similar to those of junior players, with no dominant-side effect. A history of knee injury in the professional athlete, however, was reflected in bilateral isokinetic and functional asymmetries and should be considered in future studies of explosive strength. PMID:19180217

  17. Vestibular coriolis effect differences modeled with three-dimensional linear-angular interactions.

    PubMed

    Holly, Jan E

    2004-01-01

    The vestibular coriolis (or "cross-coupling") effect is traditionally explained by cross-coupled angular vectors, which, however, do not explain the differences in perceptual disturbance under different acceleration conditions. For example, during head roll tilt in a rotating chair, the magnitude of perceptual disturbance is affected by a number of factors, including acceleration or deceleration of the chair rotation or a zero-g environment. Therefore, it has been suggested that linear-angular interactions play a role. The present research investigated whether these perceptual differences and others involving linear coriolis accelerations could be explained under one common framework: the laws of motion in three dimensions, which include all linear-angular interactions among all six components of motion (three angular and three linear). The results show that the three-dimensional laws of motion predict the differences in perceptual disturbance. No special properties of the vestibular system or nervous system are required. In addition, simulations were performed with angular, linear, and tilt time constants inserted into the model, giving the same predictions. Three-dimensional graphics were used to highlight the manner in which linear-angular interaction causes perceptual disturbance, and a crucial component is the Stretch Factor, which measures the "unexpected" linear component.

  18. Relationship of spasticity to knee angular velocity and motion during gait in cerebral palsy.

    PubMed

    Damiano, Diane L; Laws, Edward; Carmines, Dave V; Abel, Mark F

    2006-01-01

    This study investigated the effects of spasticity in the hamstrings and quadriceps muscles on gait parameters including temporal spatial measures, knee position, excursion and angular velocity in 25 children with spastic diplegic cerebral palsy (CP) as compared to 17 age-matched peers. While subjects were instructed to relax, an isokinetic device alternately flexed and extended the left knee at one of the three constant velocities 30 degrees/s, 60 degrees/s and 120 degrees/s, while surface electromyography (EMG) electrodes over the biceps femoris and the rectus femoris recorded muscle activity. Patients then participated in 3D gait analysis at a self-selected speed. Results showed that, those with CP who exhibited heightened stretch responses (spasticity) in both muscles, had significantly slower knee angular velocities during the swing phase of gait as compared to those with and without CP who did not exhibit stretch responses at the joint and the tested speeds. The measured amount (torque) of the resistance to passive flexion or extension was not related to gait parameters in subjects with CP; however, the rate of change in resistance torque per unit angle change (stiffness) at the fastest test speed of 120 degrees/s showed weak to moderate relationships with knee angular velocity and motion during gait. For the subset of seven patients with CP who subsequently underwent a selective dorsal rhizotomy, knee angular extension and flexion velocity increased post-operatively, suggesting some degree of causality between spasticity and movement speed.

  19. Adaptive force regulation of muscle strengthening rehabilitation device with magnetorheological fluids.

    PubMed

    Dong, Shufang; Lu, Ke-Qian; Sun, Jian Qiao; Rudolph, Katherine

    2006-03-01

    In rehabilitation from neuromuscular trauma or injury, strengthening exercises are often prescribed by physical therapists to recover as much function as possible. Strengthening equipment used in clinical settings range from low-cost devices, such as sandbag weights or elastic bands to large and expensive isotonic and isokinetic devices. The low-cost devices are incapable of measuring strength gains and apply resistance based on the lowest level of torque that is produced by a muscle group. Resistance that varies with joint angle can be achieved with isokinetic devices in which angular velocity is held constant and variable torque is generated when the patient attempts to move faster than the device but are ineffective if a patient cannot generate torque rapidly. In this paper, we report the development of a versatile rehabilitation device that can be used to strengthen different muscle groups based on the torque generating capability of the muscle that changes with joint angle. The device is low cost, is smaller than other commercially available machines, and can be programmed to apply resistance that is unique to a particular patient and that will optimize strengthening. The core of the device, a damper with smart magnetorheological fluids, provides passive exercise force. A digital adaptive control is capable of regulating exercise force precisely following the muscle strengthening profile prescribed by a physical therapist. The device could be programmed with artificial intelligence to dynamically adjust the target force profile to optimize rehabilitation effects. The device provides both isometric and isokinetic strength training and can be developed into a small, low-cost device that may be capable of providing optimal strengthening in the home.

  20. Tennis players show a lower coactivation of the elbow antagonist muscles during isokinetic exercises.

    PubMed

    Bazzucchi, Ilenia; Riccio, Maria Elena; Felici, Francesco

    2008-10-01

    Previous studies have suggested that muscle coactivation could be reduced by a recurrent activity (training, daily activities). If this was correct, skilled athletes should show a specific muscle activation pattern with a low level of coactivation of muscles which are typically involved in their discipline. In particular, the aim of this study was to verify the hypothesis that the amount of antagonist activation of biceps brachii (BB) and triceps brachii (TB) is different between tennis players and non-players individuals during maximal isokinetic contractions. Ten young healthy men and eight male tennis players participated in the study. The surface electromyographic signals (sEMG) were recorded from the BB and TB muscles during three maximal voluntary isometric contractions (MVC) of elbow flexors and extensors and a set of three maximal elbow flexions and extensions at 15 degrees , 30 degrees , 60 degrees , 120 degrees , 180 degrees and 240 degrees /s. Normalized root mean square (RMS) of sEMG was calculated as an index of sEMG amplitude. Antagonist activation (%RMSmax) of TB was significantly lower in tennis players (from 14.0+/-7.9% at MVC to 16.3+/-8.9% at 240 degrees /s) with respect to non-players (from 27.7+/-19.7% at MVC to 38.7+/-17.6% at 240 degrees /s) at all angular velocities. Contrary to non-players, tennis players did not show any difference in antagonist activation between BB and TB muscles. Tennis players, with a constant practice in controlling forces around the elbow joint, learn how to reduce coactivation of muscles involved in the control of this joint. This has been shown by the lower antagonist muscular activity of triceps brachii muscle during isokinetic elbow flexion found in tennis players with respect to non-players.

  1. Eccentric Torque-Producing Capacity is Influenced by Muscle Length in Older Healthy Adults.

    PubMed

    Melo, Ruth C; Takahashi, Anielle C M; Quitério, Robison J; Salvini, Tânia F; Catai, Aparecida M

    2016-01-01

    Considering the importance of muscle strength to functional capacity in the elderly, the study investigated the effects of age on isokinetic performance and torque production as a function of muscle length. Eleven younger (24.2 ± 2.9 years) and 16 older men (62.7 ± 2.5 years) were subjected to concentric and eccentric isokinetic knee extension/flexion at 60 and 120° · s(-1) through a functional range of motion. The older group presented lower peak torque (in newton-meters) than the young group for both isokinetic contraction types (age effect, p < 0.001). Peak torque deficits in the older group were near 30 and 29% for concentric and eccentric contraction, respectively. Concentric peak torque was lower at 120° · s(-1) than at 60° · s(-1) for both groups (angular velocity effect, p < 0.001). Eccentric knee extension torque was the only exercise tested that showed an interaction effect between age and muscle length (p < 0.001), which suggested different torque responses to the muscle length between groups. Compared with the young group, the eccentric knee extension torque was 22-56% lower in the older group, with the deficits being lower in the shortened muscle length (22-27%) and higher (33-56%) in the stretched muscle length. In older men, the production of eccentric knee strength seems to be dependent on the muscle length. At more stretched positions, older subjects lose the capacity to generate eccentric knee extension torque. More studies are needed to assess the mechanisms involved in eccentric strength preservation with aging and its relationship with muscle length.

  2. A Simple Piece of Apparatus to Aid the Understanding of the Relationship between Angular Velocity and Linear Velocity

    ERIC Educational Resources Information Center

    Unsal, Yasin

    2011-01-01

    One of the subjects that is confusing and difficult for students to fully comprehend is the concept of angular velocity and linear velocity. It is the relationship between linear and angular velocity that students find difficult; most students understand linear motion in isolation. In this article, we detail the design, construction and…

  3. Effects of the bilateral isokinetic strengthening training on functional parameters, gait, and the quality of life in patients with stroke.

    PubMed

    Büyükvural Şen, Sıdıka; Özbudak Demir, Sibel; Ekiz, Timur; Özgirgin, Neşe

    2015-01-01

    To evaluate the effects of the bilateral isokinetic strengthening training applied to knee and ankle muscles on balance, functional parameters, gait, and the quality of in stroke patients. Fifty patients (33 M, 17 F) with subacute-chronic stroke and 30 healthy subjects were included. Stroke patients were allocated into isokinetic and control groups. Conventional rehabilitation program was applied to all cases; additionally maximal concentric isokinetic strengthening training was applied to the knee-ankle muscles bilaterally to the isokinetic group 5 days a week for 3 weeks. Biodex System 3 Pro Multijoint System isokinetic dynamometer was used for isokinetic evaluation. The groups were assessed by Functional Independence Measure, Stroke Specific Quality of Life Scale, Timed 10-Meter Walk Test, Six-Minute Walk Test, Stair-Climbing Test, Timed up&go Test, Berg Balance Scale, and Rivermead Mobility Index. Compared with baseline, the isokinetic PT values of the knee and ankle on both sides significantly increased in all cases. PT change values were significantly higher in the isokinetic group than the control group (P<0.025). Furthermore, the quality of life, gait, balance and mobility index values improved significantly in both groups, besides the increase levels were found significantly higher in the isokinetic group (P<0.025, P<0.05). Bilateral isokinetic strengthening training in addition to conventional rehabilitation program after stroke seems to be effective on strengthening muscles on both sides, improving functional parameters, gait, balance and life quality.

  4. Effects of the bilateral isokinetic strengthening training on functional parameters, gait, and the quality of life in patients with stroke

    PubMed Central

    Büyükvural Şen, Sıdıka; Özbudak Demir, Sibel; Ekiz, Timur; Özgirgin, Neşe

    2015-01-01

    Objective: To evaluate the effects of the bilateral isokinetic strengthening training applied to knee and ankle muscles on balance, functional parameters, gait, and the quality of in stroke patients. Methods: Fifty patients (33 M, 17 F) with subacute-chronic stroke and 30 healthy subjects were included. Stroke patients were allocated into isokinetic and control groups. Conventional rehabilitation program was applied to all cases; additionally maximal concentric isokinetic strengthening training was applied to the knee-ankle muscles bilaterally to the isokinetic group 5 days a week for 3 weeks. Biodex System 3 Pro Multijoint System isokinetic dynamometer was used for isokinetic evaluation. The groups were assessed by Functional Independence Measure, Stroke Specific Quality of Life Scale, Timed 10-Meter Walk Test, Six-Minute Walk Test, Stair-Climbing Test, Timed up&go Test, Berg Balance Scale, and Rivermead Mobility Index. Results: Compared with baseline, the isokinetic PT values of the knee and ankle on both sides significantly increased in all cases. PT change values were significantly higher in the isokinetic group than the control group (P<0.025). Furthermore, the quality of life, gait, balance and mobility index values improved significantly in both groups, besides the increase levels were found significantly higher in the isokinetic group (P<0.025, P<0.05). Conclusion: Bilateral isokinetic strengthening training in addition to conventional rehabilitation program after stroke seems to be effective on strengthening muscles on both sides, improving functional parameters, gait, balance and life quality. PMID:26629238

  5. Gas exchange kinetics following concentric-eccentric isokinetic arm and leg exercise.

    PubMed

    Drescher, U; Mookerjee, S; Steegmanns, A; Knicker, A; Hoffmann, U

    2017-06-01

    To evaluate the effects of exercise velocity (60, 150, 240deg∙s -1 ) and muscle mass (arm vs leg) on changes in gas exchange and arterio-venous oxygen content difference (avDO 2 ) following high-intensity concentric-eccentric isokinetic exercise. Fourteen subjects (26.9±3.1years) performed a 3×20-repetition isokinetic exercise protocol. Recovery beat-to-beat cardiac output (CO) and breath-by-breath gas exchange were recorded to determine post-exercise half-time (t 1/2 ) for oxygen uptake (V˙O 2 pulm), carbon dioxide output (V˙CO 2 pulm), and ventilation (V˙ E ). Significant differences of the t 1/2 values were identified between 60 and 150deg∙s -1 . Significant differences in the t 1/2 values were observed between V˙O 2 pulm and V˙CO 2 pulm and between V˙CO 2 pulm and V˙ E . The time to attain the first avDO 2 -peak showed significant differences between arm and leg exercise. The present study illustrates, that V˙O 2 pulm kinetics are distorted due to non-linear CO dynamics. Therefore, it has to be taken into account, that V˙O 2 pulm may not be a valuable surrogate for muscular oxygen uptake kinetics in the recovery phases. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals.

    PubMed

    Jasiewicz, Jan M; Allum, John H J; Middleton, James W; Barriskill, Andrew; Condie, Peter; Purcell, Brendan; Li, Raymond Che Tin

    2006-12-01

    We report on three different methods of gait event detection (toe-off and heel strike) using miniature linear accelerometers and angular velocity transducers in comparison to using standard pressure-sensitive foot switches. Detection was performed with normal and spinal-cord injured subjects. The detection of end contact (EC), normally toe-off, and initial contact (IC) normally, heel strike was based on either foot linear accelerations or foot sagittal angular velocity or shank sagittal angular velocity. The results showed that all three methods were as accurate as foot switches in estimating times of IC and EC for normal gait patterns. In spinal-cord injured subjects, shank angular velocity was significantly less accurate (p<0.02). We conclude that detection based on foot linear accelerations or foot angular velocity can correctly identify the timing of IC and EC events in both normal and spinal-cord injured subjects.

  7. Estimations of relative effort during sit-to-stand increase when accounting for variations in maximum voluntary torque with joint angle and angular velocity.

    PubMed

    Bieryla, Kathleen A; Anderson, Dennis E; Madigan, Michael L

    2009-02-01

    The main purpose of this study was to compare three methods of determining relative effort during sit-to-stand (STS). Fourteen young (mean 19.6+/-SD 1.2 years old) and 17 older (61.7+/-5.5 years old) adults completed six STS trials at three speeds: slow, normal, and fast. Sagittal plane joint torques at the hip, knee, and ankle were calculated through inverse dynamics. Isometric and isokinetic maximum voluntary contractions (MVC) for the hip, knee, and ankle were collected and used for model parameters to predict the participant-specific maximum voluntary joint torque. Three different measures of relative effort were determined by normalizing STS joint torques to three different estimates of maximum voluntary torque. Relative effort at the hip, knee, and ankle were higher when accounting for variations in maximum voluntary torque with joint angle and angular velocity (hip=26.3+/-13.5%, knee=78.4+/-32.2%, ankle=27.9+/-14.1%) compared to methods which do not account for these variations (hip=23.5+/-11.7%, knee=51.7+/-15.0%, ankle=20.7+/-10.4%). At higher velocities, the difference in calculating relative effort with respect to isometric MVC or incorporating joint angle and angular velocity became more evident. Estimates of relative effort that account for the variations in maximum voluntary torque with joint angle and angular velocity may provide higher levels of accuracy compared to methods based on measurements of maximal isometric torques.

  8. The Rim Inertial Measuring System (RIMS). [to measure angular rate and linear acceleration of a moving vehicle

    NASA Technical Reports Server (NTRS)

    Groom, N. J.

    1979-01-01

    The rim inertial measuring system (RIMS) is introduced and an approach for extracting angular rate and linear acceleration information from a RIMS unit is presented and discussed. The RIMS consists of one or more small annular momentum control devices (AMCDs), mounted in a strapped down configuration, which are used to measure angular rates and linear accelerations of a moving vehicle. An AMCD consists of a spinning rim, a set of noncontacting magnetic bearings for supporting the rim, and a noncontacting electromagnetic spin motor. The approach for extracting angular rate and linear acceleration information is for a single spacecraft mounted RIMS unit.

  9. Effects of Short-Term Isokinetic Training on Standing Long-Jump Performance in Untrained Men.

    ERIC Educational Resources Information Center

    Morriss, Calvin J.; Tolfrey, Keith; Coppack, Russell J.

    2001-01-01

    Evaluated the effects of a brief isokinetic training program on quadriceps and hamstring peak torque (PT) and standing long-jump performance. Tests on 12 untrained men indicated that the brief training program was at least as effective in improving quadriceps isokinetic (but not hamstring) PT. PT gains subsequent to isokinetic resistance training…

  10. A comprehensive assessment of the cross-training effect in ankle dorsiflexors of healthy subjects: A randomized controlled study.

    PubMed

    Manca, Andrea; Pisanu, Francesco; Ortu, Enzo; De Natale, Edoardo Rosario; Ginatempo, Francesca; Dragone, Daniele; Tolu, Eusebio; Deriu, Franca

    2015-06-01

    To investigate the cross-training effect, induced on ankle dorsiflexors (AD) by unilateral strength-training of the contralateral muscles, as transfer of peak torque (PT) and muscle work (MW) and their relative contributions to muscle performance. Thirty healthy volunteers were randomly assigned to a training or control group. The trained group sustained a 4-week maximal isokinetic training of the stronger AD at 90 and 45°/s. At both angular velocities, PT, MW and MW/PT ratio were measured from both legs at baseline and after intervention (trained group) or no-intervention (controls). The familiarization/learning-effect was calculated and subtracted by PT and MW measures to obtain their net changes. Net PT increased in both legs (untrained: +27.5% at 90°/s and +17.9% at 45°/s; trained: +15% at 90°/s and +16.3% at 45°/s). Similarly, net MW increased in both the untrained (90°/s: +29.6%; 45°/s: +37%) and trained (90°/s: +23.4%; 45°/s: +18.3%) legs. PT and MW gains were larger in the untrained than trained AD (p<0.0005), with MW improving more than PT at 45°/s (p=0.04). The MW/PT ratio increased bilaterally only in the trained group (p<0.05), depending on the angular velocity. The cross-training effect occurred in AD muscles in terms of both PT and MW, with MW adding valuable information to PT-analysis in describing muscle performance. Moreover, the MW/PT ratio allowed estimating the contributions of these parameters to muscle capability and may represent a novel index in isokinetic testing. The greater improvements in the untrained than trained limb raises interesting clinical implications in asymmetric conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Knee and ankle strength and lower extremity power in adolescent female ballet dancers.

    PubMed

    Kenne, Ellinor; Unnithan, Viswanath B

    2008-01-01

    The aims of this study were twofold: (1) to compare the strength of four muscle groups of the lower limb (quadriceps [Q], hamstrings [H], plantar flexors [PF], and dorsiflexors [DF]) between female adolescent ballet dancers (BALs) and basketball players (BBs) over three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) and two types of contraction (eccentric and concentric); and (2) to compare peak and mean power between the BALs and BBs. Eleven BALs (age: 15.8 +/- 1.2 years; stature: 163.9 +/- 6.2 cm; body mass: 56.3 +/- 5.7 kg; Tanner stage 4: N=10, stage 5: N=1) and ten BBs (age: 15.8 +/- 1.0 years; stature: 172.5 +/- 5.8 cm; body mass: 63.2 +/- 10.0 kg; Tanner stage 4: N=7, stage 5: N=3) volunteered to participate. Each participant performed one habituation session and one testing session on a Biodex isokinetic dynamometer to determine peak torque. Three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) were used for each muscle group. To determine absolute and relative peak and mean power, participants performed a 30 second anaerobic Wingate test on a cycle ergometer. There were no significant differences in peak torque for Q, H, PF, and DF between the groups. Basketball players produced greater absolute peak power [569.7 +/- 82.2 vs. 454.6 +/- 79.3 W (p < .05)], relative peak power [9.1 +/- 1.3 vs. 8.1 +/- 1.0 W/kg body mass (p < .05)], absolute mean power [428.4 +/- 53.9 vs. 333.7 +/- 68.2 W (p < .05)] and relative mean power [6.83 +/- 0.7 vs. 5.9 +/- 0.7 W/kg (p < .05)] than BALs. Ballet dancers and BBs had similar isokinetically measured lower extremity muscular strength, but BALs generated lower levels of peak power and mean power compared to BBs.

  12. The Immediate Effect of Neuromuscular Joint Facilitation (NJF) Treatment on Hip Muscle Strength.

    PubMed

    Wang, Hongdan; Huo, Ming; Huang, Qiuchen; Li, Desheng; Maruyama, Hitoshi

    2013-11-01

    [Purpose] This study investigated the change in hip muscle strength of younger persons after neuromuscular joint facilitation (NJF) treatment. [Subjects] The subjects were 45 healthy young people, who were divided into two groups: a NJF group and a proprioceptive neuromuscular facilitation (PNF) group. The NJF group consisted of 21 subjects (11 males, 10 females), and the PNF group consisted of 24 subjects (11 males, 13 females). [Methods] Participants in the NJF group received NJF treatment. We measured the maximal flexor strength and the maximal extensor strength during isokinetic movement of the hip joint before and after intervention in both groups. The angular velocities used were 60°/sec and 180°/sec. [Results] The NJF group showed significant increases in the maximal flexor strength and the maximal extensor strength after the intervention at each angular velocity. In the PNF group, the maximal flexor strength of 60°/sec and the maximal extensor strength of 180°/sec were significant increases. [Conclusion] These results suggest that there is an immediate effect of NJF intervention on hip muscle strength.

  13. Modeling of functional trunk muscle performance: interfacing ergonomics and spine rehabilitation in response to the ADA.

    PubMed

    Khalaf, K A; Parnianpour, M; Sparto, P J; Simon, S R

    1997-10-01

    The combination of increasing costs of musculoskeletal injuries and the implementation of the Americans with Disabilities Act (ADA) has created the need for a more objective functional understanding of dynamic trunk performance. In this study, trunk extensor and flexor strengths were measured as a function of angular position and velocity for 20 subjects performing maximum isometric and isokinetic exertions. Results indicate that trunk strength is significantly influenced by trunk angular position, trunk angular velocity, gender, and direction, as well as by the interaction between trunk angular position and velocity. Three-dimensional surfaces of trunk strength in response to trunk angular position and velocity were constructed for each subject per direction. Such data presentation is more accurate and gives better insight about the strength profile of an individual than does the traditional use of a single strength value. The joint strength capacity profiles may be combined with joint torque requirements from a manual material handling task, such as a lifting task, to compute the dynamic utilization ratio for the trunk muscles. This ratio can be used as a unified measure of both task demand and functional capacity to guide job assignment, return to work, and prognosis during the rehabilitation processes. Furthermore, the strength regressions developed in this study would provide dynamic strength limits that can be used as functional constraints in the computer simulation of physical activities, such as lifting. In light of the ADA, this would be of great value in predicting the consequences of task modifications and/or workstation alterations without subjecting an injured worker or an individual with a disability to unnecessary testing.

  14. Measures and models for angular correlation and angular-linear correlation. [correlation of random variables

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.; Wehrly, T.

    1976-01-01

    Population models for dependence between two angular measurements and for dependence between an angular and a linear observation are proposed. The method of canonical correlations first leads to new population and sample measures of dependence in this latter situation. An example relating wind direction to the level of a pollutant is given. Next, applied to pairs of angular measurements, the method yields previously proposed sample measures in some special cases and a new sample measure in general.

  15. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

    PubMed

    Kea, J; Kramer, J; Forwell, L; Birmingham, T

    2001-08-01

    Single group, test-retest. To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

  16. The Effects of Sampling Probe Design and Sampling Techniques on Aerosol Measurements

    DTIC Science & Technology

    1975-05-01

    Schematic of Extraction and Sampling System 39 16. Filter Housing 40 17. Theoretical Isokinetic Flow Requirements of the EPA Sampling...from the flow parameters based on a zero-error assumption at isokinetic sampling conditions. Isokinetic , or equal velocity sampling, was...prior to testing the probes. It was also used to measure the flow field adjacent to the probe inlets to determine the isokinetic condition of the

  17. [Sincerity of effort: isokinetic evaluation of knee extension].

    PubMed

    Colombo, R; Demaiti, G; Sartorio, F; Orlandini, D; Vercelli, S; Ferriero, G

    2008-01-01

    The aim of this study was to find a reliable method to evaluate the sincerity of the muscular maximal effort performed in a dynamometric isokinetic test of knee flexion-extension. The coefficient of variation of the peak torque (CV) and 3 new indices were analysed: (1) the average coefficient of variation calculated on the complete peak torque curve (CVM); (2) the slope of the regression line in an endurance test (PRR); (3) the correlation coefficient of the peak torques in the same endurance test (CCR). Twenty healthy subjects underwent assessment in two different trials, maximal (MX) and 50% submaximal (SMX), with 20 minutes of rest between trials. Each trial consisted of 4 tests, each of 3 repetitions, at angular speed of 30, 180, 30, and 180 degrees/s, respectively, and 1 test of 15 repetitions at 240 degrees/s. Our findings confirmed the ability of CV to detect a high percentage of sincere efforts: at 30 degrees/s Sensibility (Sns)=100% and Specificity (Spc)=70%; at 180 degrees/s Sns=75%, Spc=95%. The 3 new indices here proposed showed high characteristics of Sns and Spc, generally better than those of CV. CVM showed at 180 degrees/s Sns=90% and Spc=100%, while at 30 degrees/s Sns=90%, Spc=75%. PRR was the best index identifying all the efforts, except one (Sns=100%, Spc=95%). The CCR coefficient showed Sns and Spc values both of 90%.

  18. Hamstrings strength imbalance in professional football (soccer) players in Australia.

    PubMed

    Ardern, Clare L; Pizzari, Tania; Wollin, Martin R; Webster, Kate E

    2015-04-01

    The aim of this study was to describe the isokinetic thigh muscle strength profile of professional male football players in Australia. Concentric (60° and 240°·s(-1)) and eccentric (30° and 120°·s(-1)) hamstrings and quadriceps isokinetic strength was measured with a HUMAC NORM dynamometer. The primary variables were bilateral concentric and eccentric hamstring and quadriceps peak torque ratios, concentric hamstring-quadriceps peak torque ratios, and mixed ratios (eccentric hamstring 30°·s(-1) ÷ concentric quadriceps 240°·s(-1)). Hamstring strength imbalance was defined as deficits in any 2 of: bilateral concentric hamstring peak torque ratio <0.86, bilateral eccentric hamstring peak torque ratio <0.86, concentric hamstring-quadriceps ratio <0.47, and mixed ratio <0.80. Fifty-five strength tests involving 42 players were conducted. Ten players (24%) were identified as having hamstring strength imbalance. Athletes with strength imbalance had significantly reduced concentric and eccentric bilateral hamstring peak torque ratios at all angular velocities tested; and reduced eccentric quadriceps peak torque (30°·s(-1)) in their stance leg, compared with those without strength imbalance. Approximately, 1 in 4 players had preseason hamstring strength imbalance; and all strength deficits were observed in the stance leg. Concentric and eccentric hamstrings strength imbalance may impact in-season football performance and could have implications for the future risk of injury.

  19. Angular Impulse and Balance Regulation During the Golf Swing.

    PubMed

    Peterson, Travis J; Wilcox, Rand R; McNitt-Gray, Jill L

    2016-08-01

    Our aim was to determine how skilled players regulate linear and angular impulse while maintaining balance during the golf swing. Eleven highly-skilled golf players performed swings with a 6-iron and driver. Components contributing to linear and angular impulse generated by the rear and target legs (resultant horizontal reaction force [RFh], RFh-angle, and moment arm) were quantified and compared across the group and within a player (α = .05). Net angular impulse generated by both the rear and target legs was greater for the driver than the 6-iron. Mechanisms used to regulate angular impulse generation between clubs varied across players and required coordination between the legs. Increases in net angular impulse with a driver involved increases in target leg RFh. Rear leg RFh-angle was maintained between clubs whereas target leg RFh became more aligned with the target line. Net linear impulse perpendicular to the target line remained near zero, preserving balance, while net linear impulse along the target line decreased in magnitude. These results indicate that the net angular impulse was regulated between clubs by coordinating force generation of the rear and target legs while sustaining balance throughout the task.

  20. Noncircular Chainrings Do Not Influence Maximum Cycling Power.

    PubMed

    Leong, Chee-Hoi; Elmer, Steven J; Martin, James C

    2017-12-01

    Noncircular chainrings could increase cycling power by prolonging the powerful leg extension/flexion phases, and curtailing the low-power transition phases. We compared maximal cycling power-pedaling rate relationships, and joint-specific kinematics and powers across 3 chainring eccentricities (CON = 1.0; LOW ecc  = 1.13; HIGH ecc  = 1.24). Part I: Thirteen cyclists performed maximal inertial-load cycling under 3 chainring conditions. Maximum cycling power and optimal pedaling rate were determined. Part II: Ten cyclists performed maximal isokinetic cycling (120 rpm) under the same 3 chainring conditions. Pedal and joint-specific powers were determined using pedal forces and limb kinematics. Neither maximal cycling power nor optimal pedaling rate differed across chainring conditions (all p > .05). Peak ankle angular velocity for HIGH ecc was less than CON (p < .05), while knee and hip angular velocities were unaffected. Self-selected ankle joint-center trajectory was more eccentric than HIGH ecc with an opposite orientation that increased velocity during extension/flexion and reduced velocity during transitions. Joint-specific powers did not differ across chainring conditions, with a small increase in power absorbed during ankle dorsiflexion with HIGH ecc . Multiple degrees of freedom in the leg, crank, and pedal system allowed cyclists to manipulate ankle angular velocity to maintain their preferred knee and hip actions, suggesting maximizing extension/flexion and minimizing transition phases may be counterproductive for maximal power.

  1. Isokinetic Extension Strength Is Associated With Single-Leg Vertical Jump Height.

    PubMed

    Fischer, Felix; Blank, Cornelia; Dünnwald, Tobias; Gföller, Peter; Herbst, Elmar; Hoser, Christian; Fink, Christian

    2017-11-01

    Isokinetic strength testing is an important tool in the evaluation of the physical capacities of athletes as well as for decision making regarding return to sports after anterior cruciate ligament (ACL) reconstruction in both athletes and the lay population. However, isokinetic testing is time consuming and requires special testing equipment. A single-jump test, regardless of leg dominance, may provide information regarding knee extension strength through the use of correlation analysis of jump height and peak torque of isokinetic muscle strength. Cross-sectional study; Level of evidence, 3. A total of 169 patients who underwent ACL reconstruction were included in this study. Isokinetic testing was performed on the injured and noninjured legs. Additionally, a single-leg countermovement jump was performed to assess jump height using a jump accelerometer sensor. Extension strength values were used to assess the association between isokinetic muscle strength and jump height. The sample consisted of 60 female (mean age, 20.8 ± 8.3 years; mean weight, 61.7 ± 6.5 kg; mean height, 167.7 ± 5.3 cm) and 109 male (mean age, 23.2 ± 7.7 years; mean weight, 74.6 ± 10.2 kg; mean height, 179.9 ± 6.9 cm) patients. Bivariate correlation analysis showed an association ( r = 0.56, P < .001) between jump height and isokinetic extension strength on the noninvolved side as well as an association ( r = 0.52, P < .001) for the involved side. Regression analysis showed that in addition to jump height (beta = 0.49, P < .001), sex (beta = -0.17, P = .008) and body mass index (beta = 0.37, P < .001) affected isokinetic strength. The final model explained 51.1% of the variance in isokinetic muscle strength, with jump height having the strongest impact (beta = 0.49, P < .001) and explaining 31.5% of the variance. Initial analysis showed a strong association between isokinetic strength and jump height. The study population encompassed various backgrounds, skill levels, and activity profiles, which might have affected the outcome. Even after controlling for age and sex, isokinetic strength was still moderately associated with jump height. Therefore, the jump technique and type of sport should be considered in future research.

  2. Isokinetic exercise: A review of the literature

    NASA Technical Reports Server (NTRS)

    Olree, H. D.; Corbin, B.; Smith, C.

    1978-01-01

    Isokinetic muscle training has all the advantages of isometrics and isotonics while minimizing their deficiencies. By holding the speed of movement constant throughout the full range of motion, isokinetic training devices respond with increased resistance rather than acceleration when the power output of the muscle is increased. Isokinetic training is superior to isometric and isotonic training with respect to increases in strength, specificity of training, desirable changes in motor performance tasks, lack of muscle soreness, and decreases in relative body fat.

  3. Wireless acceleration sensor of moving elements for condition monitoring of mechanisms

    NASA Astrophysics Data System (ADS)

    Sinitsin, Vladimir V.; Shestakov, Aleksandr L.

    2017-09-01

    Comprehensive analysis of the angular and linear accelerations of moving elements (shafts, gears) allows an increase in the quality of the condition monitoring of mechanisms. However, existing tools and methods measure either linear or angular acceleration with postprocessing. This paper suggests a new construction design of an angular acceleration sensor for moving elements. The sensor is mounted on a moving element and, among other things, the data transfer and electric power supply are carried out wirelessly. In addition, the authors introduce a method for processing the received information which makes it possible to divide the measured acceleration into the angular and linear components. The design has been validated by the results of laboratory tests of an experimental model of the sensor. The study has shown that this method provides a definite separation of the measured acceleration into linear and angular components, even in noise. This research contributes an advance in the range of methods and tools for condition monitoring of mechanisms.

  4. [Reliability and validity of the analysis of hand grip and pinch force in isometric and isokinetic conditions].

    PubMed

    Benaglia, P G; Franchignoni, F; Ferriero, G; Zebellin, G; Sartorio, F

    1999-01-01

    Strength measurement of the hand grip is at the core of most protocols of functional assessment of the upper limb and in rehabilitation plays a major role in the analysis of treatment efficacy and patients' occupational ability. The aims of this study were to: a) verify the repeatability of strength measurements made during performance of the hand grip and three types of pinch, carried out under isometric and isokinetic conditions; b) compare maximal isometric strength with the corresponding isokinetic value for each of the manoeuvres studied; c) investigate the correlations between the strength expressed in the different manoeuvres, under both isometric and isokinetic conditions. We studied 14 voluntary subjects over three sessions conducted at 48-hr intervals, employing a computerized isokinetic dynamometer Lido WorkSet equipped with device N(o) 21 for the study of pinch (lateral pinch, pulp pinch, chuck pinch) and device N(o) 52 for the grip study. Isometric contractions resulted stronger than isokinetic ones, and the hand grip was found to be the manoeuvre able to produce most strength. The repeatability of each strength measurement test over the three days was high (Intraclass Correlation Coefficients: 0.89-0.93). Correlations between the isometric and isokinetic performance for each of the manoeuvres examined were always high (Pearson's r coefficients: 0.89-0.95) as were those between the different manoeuvres, whether performed in isometric or isokinetic modality (r: 0.60-0.94).

  5. Influence of tungsten fiber’s slow drift on the measurement of G with angular acceleration method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Jie; Wu, Wei-Huang; Zhan, Wen-Ze

    In the measurement of the gravitational constant G with angular acceleration method, the equilibrium position of torsion pendulum with tungsten fiber undergoes a linear slow drift, which results in a quadratic slow drift on the angular velocity of the torsion balance turntable under feedback control unit. The accurate amplitude determination of the useful angular acceleration signal with known frequency is biased by the linear slow drift and the coupling effect of the drifting equilibrium position and the room fixed gravitational background signal. We calculate the influences of the linear slow drift and the complex coupling effect on the value ofmore » G, respectively. The result shows that the bias of the linear slow drift on G is 7 ppm, and the influence of the coupling effect is less than 1 ppm.« less

  6. Influence of tungsten fiber's slow drift on the measurement of G with angular acceleration method.

    PubMed

    Luo, Jie; Wu, Wei-Huang; Xue, Chao; Shao, Cheng-Gang; Zhan, Wen-Ze; Wu, Jun-Fei; Milyukov, Vadim

    2016-08-01

    In the measurement of the gravitational constant G with angular acceleration method, the equilibrium position of torsion pendulum with tungsten fiber undergoes a linear slow drift, which results in a quadratic slow drift on the angular velocity of the torsion balance turntable under feedback control unit. The accurate amplitude determination of the useful angular acceleration signal with known frequency is biased by the linear slow drift and the coupling effect of the drifting equilibrium position and the room fixed gravitational background signal. We calculate the influences of the linear slow drift and the complex coupling effect on the value of G, respectively. The result shows that the bias of the linear slow drift on G is 7 ppm, and the influence of the coupling effect is less than 1 ppm.

  7. Influence of tungsten fiber's slow drift on the measurement of G with angular acceleration method

    NASA Astrophysics Data System (ADS)

    Luo, Jie; Wu, Wei-Huang; Xue, Chao; Shao, Cheng-Gang; Zhan, Wen-Ze; Wu, Jun-Fei; Milyukov, Vadim

    2016-08-01

    In the measurement of the gravitational constant G with angular acceleration method, the equilibrium position of torsion pendulum with tungsten fiber undergoes a linear slow drift, which results in a quadratic slow drift on the angular velocity of the torsion balance turntable under feedback control unit. The accurate amplitude determination of the useful angular acceleration signal with known frequency is biased by the linear slow drift and the coupling effect of the drifting equilibrium position and the room fixed gravitational background signal. We calculate the influences of the linear slow drift and the complex coupling effect on the value of G, respectively. The result shows that the bias of the linear slow drift on G is 7 ppm, and the influence of the coupling effect is less than 1 ppm.

  8. Chiral resolution of spin angular momentum in linearly polarized and unpolarized light

    PubMed Central

    Hernández, R. J.; Mazzulla, A.; Provenzano, C.; Pagliusi, P.; Cipparrone, G.

    2015-01-01

    Linearly polarized (LP) and unpolarized (UP) light are racemic entities since they can be described as superposition of opposite circularly polarized (CP) components of equal amplitude. As a consequence they do not carry spin angular momentum. Chiral resolution of a racemate, i.e. separation of their chiral components, is usually performed via asymmetric interaction with a chiral entity. In this paper we provide an experimental evidence of the chiral resolution of linearly polarized and unpolarized Gaussian beams through the transfer of spin angular momentum to chiral microparticles. Due to the interplay between linear and angular momentum exchange, basic manipulation tasks, as trapping, spinning or orbiting of micro-objects, can be performed by light with zero helicity. The results might broaden the perspectives for development of miniaturized and cost-effective devices. PMID:26585284

  9. Angular velocity discrimination

    NASA Technical Reports Server (NTRS)

    Kaiser, Mary K.

    1990-01-01

    Three experiments designed to investigate the ability of naive observers to discriminate rotational velocities of two simultaneously viewed objects are described. Rotations are constrained to occur about the x and y axes, resulting in linear two-dimensional image trajectories. The results indicate that observers can discriminate angular velocities with a competence near that for linear velocities. However, perceived angular rate is influenced by structural aspects of the stimuli.

  10. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    PubMed

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Ib.

  11. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.

    PubMed

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-02-01

    Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student's T test was used. There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction.

  12. Isokinetic Extension Strength Is Associated With Single-Leg Vertical Jump Height

    PubMed Central

    Fischer, Felix; Blank, Cornelia; Dünnwald, Tobias; Gföller, Peter; Herbst, Elmar; Hoser, Christian; Fink, Christian

    2017-01-01

    Background: Isokinetic strength testing is an important tool in the evaluation of the physical capacities of athletes as well as for decision making regarding return to sports after anterior cruciate ligament (ACL) reconstruction in both athletes and the lay population. However, isokinetic testing is time consuming and requires special testing equipment. Hypothesis: A single-jump test, regardless of leg dominance, may provide information regarding knee extension strength through the use of correlation analysis of jump height and peak torque of isokinetic muscle strength. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 169 patients who underwent ACL reconstruction were included in this study. Isokinetic testing was performed on the injured and noninjured legs. Additionally, a single-leg countermovement jump was performed to assess jump height using a jump accelerometer sensor. Extension strength values were used to assess the association between isokinetic muscle strength and jump height. Results: The sample consisted of 60 female (mean age, 20.8 ± 8.3 years; mean weight, 61.7 ± 6.5 kg; mean height, 167.7 ± 5.3 cm) and 109 male (mean age, 23.2 ± 7.7 years; mean weight, 74.6 ± 10.2 kg; mean height, 179.9 ± 6.9 cm) patients. Bivariate correlation analysis showed an association (r = 0.56, P < .001) between jump height and isokinetic extension strength on the noninvolved side as well as an association (r = 0.52, P < .001) for the involved side. Regression analysis showed that in addition to jump height (beta = 0.49, P < .001), sex (beta = –0.17, P = .008) and body mass index (beta = 0.37, P < .001) affected isokinetic strength. The final model explained 51.1% of the variance in isokinetic muscle strength, with jump height having the strongest impact (beta = 0.49, P < .001) and explaining 31.5% of the variance. Conclusion: Initial analysis showed a strong association between isokinetic strength and jump height. The study population encompassed various backgrounds, skill levels, and activity profiles, which might have affected the outcome. Even after controlling for age and sex, isokinetic strength was still moderately associated with jump height. Therefore, the jump technique and type of sport should be considered in future research. PMID:29147670

  13. Cubature/ Unscented/ Sigma Point Kalman Filtering with Angular Measurement Models

    DTIC Science & Technology

    2015-07-06

    Cubature/ Unscented/ Sigma Point Kalman Filtering with Angular Measurement Models David Frederic Crouse Naval Research Laboratory 4555 Overlook Ave...measurement and process non- linearities, such as the cubature Kalman filter , can perform ex- tremely poorly in many applications involving angular... Kalman filtering is a realization of the best linear unbiased estimator (BLUE) that evaluates certain integrals for expected values using different forms

  14. Efficacy of isokinetic exercise on functional capacity and pain in patellofemoral pain syndrome.

    PubMed

    Alaca, Ridvan; Yilmaz, Bilge; Goktepe, A Salim; Mohur, Haydar; Kalyon, Tunc Alp

    2002-11-01

    To assess the effect of an isokinetic exercise program on symptoms and functions of patients with patellofemoral pain syndrome. A total of 22 consecutive patients with the complaint of anterior knee pain who met the inclusion criteria were recruited to assess the efficacy of isokinetic exercise on functional capacity, isokinetic parameters, and pain scores in patients with patellofemoral pain syndrome. A total of 37 knees were examined. Six-meter hopping, three-step hopping, and single-limb hopping course tests were performed for each patient with the measurements of the Lysholm scale and visual analog scale. Tested parameters were peak torque, total work, average power, and endurance ratios. Statistical analyses revealed that at the end of the 6-wk treatment period, functional and isokinetic parameters improved significantly, as did pain scores. There was not statistically significant correlation between different groups of parameters. The isokinetic exercise treatment program used in this study prevented the extensor power loss due to patellofemoral pain syndrome, but the improvement in the functional capacity was not correlated with the gained power.

  15. Signal processing related to the vestibulo-ocular reflex during combined angular rotation and linear translation of the head

    NASA Technical Reports Server (NTRS)

    McCrea, R. A.; Chen-Huang, C.; Peterson, B. W. (Principal Investigator)

    1999-01-01

    The contributions of vestibular nerve afferents and central vestibular pathways to the angular (AVOR) and linear (LVOR) vestibulo-ocular reflex were studied in squirrel monkeys during fixation of near and far targets. Irregular vestibular afferents did not appear to be necessary for the LVOR, since when they were selectively silenced with galvanic currents the LVOR was essentially unaffected during both far- and near-target viewing. The linear translation signals generated by secondary AVOR neurons in the vestibular nuclei were, on average, in phase with head velocity, inversely related to viewing distance, and were nearly as strong as AVOR-related signals. We suggest that spatial-temporal transformation of linear head translation signals to angular eye velocity commands is accomplished primarily by the addition of viewing distance multiplied, centrally integrated, otolith regular afferent signals to angular VOR pathways.

  16. Blending Velocities In Task Space In Computing Robot Motions

    NASA Technical Reports Server (NTRS)

    Volpe, Richard A.

    1995-01-01

    Blending of linear and angular velocities between sequential specified points in task space constitutes theoretical basis of improved method of computing trajectories followed by robotic manipulators. In method, generalized velocity-vector-blending technique provides relatively simple, common conceptual framework for blending linear, angular, and other parametric velocities. Velocity vectors originate from straight-line segments connecting specified task-space points, called "via frames" and represent specified robot poses. Linear-velocity-blending functions chosen from among first-order, third-order-polynomial, and cycloidal options. Angular velocities blended by use of first-order approximation of previous orientation-matrix-blending formulation. Angular-velocity approximation yields small residual error, quantified and corrected. Method offers both relative simplicity and speed needed for generation of robot-manipulator trajectories in real time.

  17. Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section.

    PubMed

    Patts, Justin R; Barone, Teresa L

    2017-05-01

    Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over "off-the-shelf" sampling cassettes.

  18. Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section

    PubMed Central

    Patts, Justin R.; Barone, Teresa L.

    2017-01-01

    Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over “off-the-shelf” sampling cassettes. PMID:27792474

  19. Correlation of ankle eversion to inversion strength ratio and static balance in dominant and non-dominant limbs of basketball players.

    PubMed

    Dabadghav, Rachana

    2016-04-01

    To compare ankle eversion to inversion strength ratio (E/I R) and static balance control between the dominant and non-dominant limbs of basketball players and to correlate ankle E/I R and static balance control in the dominant and non-dominant limbs of basketball players. Twenty-one healthy basketball players in the age-group of 18-25 years participated in this study. Isokinetic ankle eversion and inversion muscle strength was assessed at 30°/s and 120°/s in both dominant and non-dominant limbs using the Biodex isokinetic dynamometer. Similarly balance was assessed on a force platform with eyes open and eyes closed in both dominant and non-dominant limbs. Repeated measure ANOVA for strength measurement, found that there was significant main effect of speed, P=0.001 (P<0.05). However, there was no significant main effect in the sides P=0.099 (P<0.05).There was significant main effect of sides with respect to balance. Balance was affected more in non-dominant limb P=0.000 as compared to dominant limb. However, there was not much of a significant difference with eyes open and eyes closed position. The E/I ratio was >1.0 at the angular velocity of 120°/s increasing the chances of ankle injuries in basketball players. There was no correlation between ankle strength and balance in both dominant and non-dominant limbs.

  20. Different Muscle Action Training Protocols on Quadriceps-Hamstrings Neuromuscular Adaptations.

    PubMed

    Ruas, Cassio V; Brown, Lee E; Lima, Camila D; Gregory Haff, G; Pinto, Ronei S

    2018-05-01

    The aim of this study was to compare three specific concentric and eccentric muscle action training protocols on quadriceps-hamstrings neuromuscular adaptations. Forty male volunteers performed 6 weeks of training (two sessions/week) of their dominant and non-dominant legs on an isokinetic dynamometer. They were randomly assigned to one of four groups; concentric quadriceps and concentric hamstrings (CON/CON, n=10), eccentric quadriceps and eccentric hamstrings (ECC/ECC, n=10), concentric quadriceps and eccentric hamstrings (CON/ECC, n=10), or no training (CTRL, n=10). Intensity of training was increased every week by decreasing the angular velocity for concentric and increasing it for eccentric groups in 30°/s increments. Volume of training was increased by adding one set every week. Dominant leg quadriceps and hamstrings muscle thickness, muscle quality, muscle activation, muscle coactivation, and electromechanical delay were tested before and after training. Results revealed that all training groups similarly increased MT of quadriceps and hamstrings compared to control (p<0.05). However, CON/ECC and ECC/ECC training elicited a greater magnitude of change. There were no significant differences between groups for all other neuromuscular variables (p>0.05). These findings suggest that different short-term muscle action isokinetic training protocols elicit similar muscle size increases in hamstrings and quadriceps, but not for other neuromuscular variables. Nevertheless, effect sizes indicate that CON/ECC and ECC/ECC may elicit the greatest magnitude of change in muscle hypertrophy. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Prediction of hamstring injury in professional soccer players by isokinetic measurements

    PubMed Central

    Dauty, Marc; Menu, Pierre; Fouasson-Chailloux, Alban; Ferréol, Sophie; Dubois, Charles

    2016-01-01

    Summary Objectives previous studies investigating the ability of isokinetic strength ratios to predict hamstring injuries in soccer players have reported conflicting results. Hypothesis to determine if isokinetic ratios are able to predict hamstring injury occurring during the season in professional soccer players. Study Design case-control study; Level of evidence: 3. Methods from 2001 to 2011, 350 isokinetic tests were performed in 136 professional soccer players at the beginning of the soccer season. Fifty-seven players suffered hamstring injury during the season that followed the isokinetic tests. These players were compared with the 79 uninjured players. The bilateral concentric ratio (hamstring-to-hamstring), ipsilateral concentric ratio (hamstring-to-quadriceps), and mixed ratio (eccentric/concentric hamstring-to-quadriceps) were studied. The predictive ability of each ratio was established based on the likelihood ratio and post-test probability. Results the mixed ratio (30 eccentric/240 concentric hamstring-to-quadriceps) <0.8, ipsilateral ratio (180 concentric hamstring-to-quadriceps) <0.47, and bilateral ratio (60 concentric hamstring-to-hamstring) <0.85 were the most predictive of hamstring injury. The ipsilateral ratio <0.47 allowed prediction of the severity of the hamstring injury, and was also influenced by the length of time since administration of the isokinetic tests. Conclusion isokinetic ratios are useful for predicting the likelihood of hamstring injury in professional soccer players during the competitive season. PMID:27331039

  2. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults

    PubMed Central

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Summary Background Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. Objective The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Methods Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. Results All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. Conclusions The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Level of evidence Ib. PMID:29264344

  3. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction

    PubMed Central

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-01-01

    Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student’s T test was used. Results: There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Conclusion: Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction. PMID:25870471

  4. Properties of Isokinetic Fatigue at Various Movement Speeds in Adult Males.

    ERIC Educational Resources Information Center

    Clarke, David H.; Manning, James M.

    1985-01-01

    Eighteen male subjects, aged 20 to 28 years, engaged in three fatigue bouts using an isokinetic dynamometer to measure knee extension contractions. Peak torque varied inversely with movement speed, and the pattern of decrement was independent of speed. Time to peak torque did not change significantly across trials in isokinetic fatigue. (Author/MT)

  5. THE ACUTE EFFECTS OF CONCENTRIC VERSUS ECCENTRIC MUSCLE FATIGUE ON SHOULDER ACTIVE REPOSITIONING SENSE

    PubMed Central

    2017-01-01

    Purpose/Background Shoulder proprioception is essential in the activities of daily living as well as in sports. Acute muscle fatigue is believed to cause a deterioration of proprioception, increasing the risk of injury. The purpose of this study was to evaluate if fatigue of the shoulder external rotators during eccentric versus concentric activity affects shoulder joint proprioception as determined by active reproduction of position. Study design Quasi-experimental trial. Methods Twenty-two healthy subjects with no recent history of shoulder pathology were randomly allocated to either a concentric or an eccentric exercise group for fatiguing the shoulder external rotators. Proprioception was assessed before and after the fatiguing protocol using an isokinetic dynamometer, by measuring active reproduction of position at 30 ° of shoulder external rotation, reported as absolute angular error. The fatiguing protocol consisted of sets of fifteen consecutive external rotator muscle contractions in either the concentric or eccentric action. The subjects were exercised until there was a 30% decline from the peak torque of the subjects’ maximal voluntary contraction over three consecutive muscle contractions. Results A one-way analysis of variance test revealed no statistical difference in absolute angular error (p > 0.05) between concentric and eccentric groups. Moreover, no statistical difference (p > 0.05) was found in absolute angular error between pre- and post-fatigue in either group. Conclusions Eccentric exercise does not seem to acutely affect shoulder proprioception to a larger extent than concentric exercise. Level of evidence 2b PMID:28515976

  6. Internal- and External-Rotation Peak Toque in Little League Baseball Players With Subacromial Impingement Syndrome: Improved by Closed Kinetic Chain Shoulder Training.

    PubMed

    Lee, Dong-Rour; Kim, Laurentius Jongsoon

    2016-08-01

    Many studies have explored closed kinetic chain (CKC) shoulder exercises (SEs) with a sling because they are safer and more effective than open-chain exercises, especially in early stages of treatment. However, the application of CKC SE in youth baseball players has rarely been attempted, although teenage baseball players also experience shoulder pain. To investigate the effects of CKC SE on the peak torque of shoulder internal rotation (IR) and external rotation (ER) in youth baseball players. Single-group pretest, posttest. Biomechanics laboratory. 23 Little League Baseball players with subacromial impingement syndrome. The CKC SE with a sling was CKC shoulder-flexion exercise, extension exercise, IR exercise, and ER exercise. This exercise regimen was conducted 2 or 3 times/wk for 8 wk. The peak torque of shoulder IR and ER was measured using an isokinetic dynamometer. Concentric shoulder rotation was performed, with 5 repetitions at an angular velocity of 60°/s and 15 at 180°/s. The IR and ER peak torque significantly increased at each angular velocity after the exercise program. In particular, the increase in IR and ER peak torque values was statistically significant at an angular velocity of 180°/s. CKC SE was effective in increasing shoulder IR and ER strength, demonstrating its potential benefits in the prevention and treatment of shoulder injury. In addition, increased IR peak torque appears to improve throwing velocity in baseball players.

  7. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    NASA Technical Reports Server (NTRS)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  8. Interseason variability in isokinetic strength and poor correlation with Nordic hamstring eccentric strength in football players.

    PubMed

    van Dyk, N; Witvrouw, E; Bahr, R

    2018-04-25

    In elite sport, the use of strength testing to establish muscle function and performance is common. Traditionally, isokinetic strength tests have been used, measuring torque during concentric and eccentric muscle action. A device that measures eccentric hamstring muscle strength while performing the Nordic hamstring exercise is now also frequently used. The study aimed to investigate the variability of isokinetic muscle strength over time, for example, between seasons, and the relationship between isokinetic testing and the new Nordic hamstring exercise device. All teams (n = 18) eligible to compete in the premier football league in Qatar underwent a comprehensive strength assessment during their periodic health evaluation at Aspetar Orthopaedic and Sports Medicine Hospital in Qatar. Isokinetic strength was investigated for measurement error, and correlated to Nordic hamstring exercise strength. Of the 529 players included, 288 players had repeated tests with 1/2 seasons between test occasions. Variability (measurement error) between test occasions was substantial, as demonstrated by the measurement error (approximately 25 Nm, 15%), whether separated by 1 or 2 seasons. Considering hamstring injuries, the same pattern was observed among injured (n = 60) and uninjured (n = 228) players. A poor correlation (r = .35) was observed between peak isokinetic hamstring eccentric torque and Nordic hamstring exercise peak force. The strength imbalance between limbs calculated for both test modes was not correlated (r = .037). There is substantial intraindividual variability in all isokinetic test measures, whether separated by 1 or 2 seasons, irrespective of injury. Also, eccentric hamstring strength and limb-to-limb imbalance were poorly correlated between the isokinetic and Nordic hamstring exercise tests. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. The Effect of Concentric Isokinetic Strength Training of the Quadriceps Femoris on Electromyography and Muscle Strength in the Trained and Untrained Limb.

    ERIC Educational Resources Information Center

    Evetovich, Tammy K.; Housh, Terry J.; Housh, Dona J.; Johnson, Glen O.; Smith, Douglas B.; Ebersole, Kyle T.

    2001-01-01

    Examined the effects of unilateral concentric isokinetic leg extension training on peak torque and electromyographic (EMG) responses in trained and untrained limbs. Adult men participated in training and control groups. Overall, unilateral concentric isokinetic strength training induced strength increases in trained as well as untrained limbs.…

  10. Rotator cuff strength in recurrent anterior shoulder instability.

    PubMed

    Edouard, Pascal; Degache, Francis; Beguin, Laurent; Samozino, Pierre; Gresta, Giorgio; Fayolle-Minon, Isabelle; Farizon, Frédéric; Calmels, Paul

    2011-04-20

    Although rotator-cuff muscle contraction plays an important role in stabilizing the glenohumeral joint, little is known about the role of these muscles in the pathophysiology of recurrent anterior instability. We intended to analyze the association between isokinetic internal rotator and external rotator muscle strength and glenohumeral joint instability in patients with recurrent anterior instability that was not previously treated surgically. We enrolled thirty-seven patients with unilateral recurrent anterior posttraumatic shoulder dislocation and eleven healthy nonathletic subjects in this controlled study. The association between internal rotator and external rotator strength and shoulder instability was analyzed by side-to-side comparisons and comparisons with a control group. Isokinetic internal rotator and external rotator strength was evaluated with a Con-Trex dynamometer, with the subject seated and the shoulder abducted 45° in the scapular plane. Tests were performed at 180°/s, 120°/s, and 60°/s in concentric mode for both sides. Peak torque normalized to body weight and external rotator to internal rotator ratio were calculated for each angular velocity. Clinical and isokinetic evaluation was done by the same rehabilitation physician. The association between shoulder instability and internal rotator and external rotator strength was associated with side-to-side differences (p < 0.05). Compared with a control group, strength values were lower on the pathological shoulder side of the patients with shoulder instability than on the healthy contralateral shoulder of control subjects at 180°/s and 120°/s (p < 0.05). The side-to-side differences were increased when the nondominant upper-extremity side was involved and were decreased when the dominant side was involved. There was no association between glenohumeral joint instability and external rotator to internal rotator ratio. Internal rotator and external rotator weakness was associated with recurrent anterior instability, and side-to-side differences depended on the side of hand dominance. Use of a control group may help in the analysis of the influence of constraints on shoulder strength. Further prospective studies are necessary to determine whether the weakness is a cause or an effect of the instability.

  11. Myocellular enzyme leakage, polymorphonuclear neutrophil activation and delayed onset muscle soreness induced by isokinetic eccentric exercise.

    PubMed

    Croisier, J L; Camus, G; Deby-Dupont, G; Bertrand, F; Lhermerout, C; Crielaard, J M; Juchmès-Ferir, A; Deby, C; Albert, A; Lamy, M

    1996-01-01

    To address the question of whether delayed onset muscular soreness (DOMS) following intense eccentric muscle contraction could be due to increased production of the arachidonic acid derived product prostaglandin E2 (PGE2). 10 healthy male subjects were submitted to eccentric and concentric isokinetic exercises on a Kin Trex device at 60 degrees/s angular velocity. Exercise consisted of 8 stages of 5 maximal contractions of the knee extensor and flexor muscle groups of both legs separated by 1 min rest phases. There was an interval of at least 30 days between eccentric and concentric testing, and the order of the two exercise sessions was randomly assigned. The subjective presence and intensity of DOMS was evaluated using a visual analogue scale, immediately, following 24 h and 48 h after each test. Five blood samples were drawn from an antecubital vein: at rest before exercise, immediately after, after 30 min recovery, 24 h and 48 h after the tests. The magnitude of the acute inflammatory response to exercise was assessed by measuring plasma levels of polymorphonuclear elastase ([EL]), myeloperoxidase ([MPO]) and PGE2 ([PGE2]). Using two way analysis of variance, it appeared that only eccentric exercise significantly increased [EL] and DOMS, especially of the hamstring muscles. Furthermore, a significant decrease in eccentric peak torque of this muscle group only was observed on day 2 after eccentric work (- 21%; P < 0.002). Serum activity of creatine kinase and serum concentration of myoglobin increased significantly 24 and 48 h after both exercise tests. However, these variables reached significantly higher values following eccentric contractions 48 h after exercise. Mean [PGE2] in the two exercise modes remained unchanged over time and were practically equal at each time point. On the basis of these findings, we conclude that the magnitude of polymorphonuclear (PMN) activation, muscle damage, and DOMS are greater after eccentric than after concentric muscle contractions. However, the hypothesized interplay between muscle damage, increased PGE2 production, DOMS sensations, and reduced isokinetic muscle performance was not substantiated by the present results.

  12. The azimuthal component of Poynting's vector and the angular momentum of light

    NASA Astrophysics Data System (ADS)

    Cameron, Robert P.; Speirits, Fiona C.; Gilson, Claire R.; Allen, L.; Barnett, Stephen M.

    2015-12-01

    The usual description in basic electromagnetic theory of the linear and angular momenta of light is centred upon the identification of Poynting's vector as the linear momentum density and its cross product with position, or azimuthal component, as the angular momentum density. This seemingly reasonable approach brings with it peculiarities, however, in particular with regards to the separation of angular momentum into orbital and spin contributions, which has sometimes been regarded as contrived. In the present paper, we observe that densities are not unique, which leads us to ask whether the usual description is, in fact, the most natural choice. To answer this, we adopt a fundamental rather than heuristic approach by first identifying appropriate symmetries of Maxwell's equations and subsequently applying Noether's theorem to obtain associated conservation laws. We do not arrive at the usual description. Rather, an equally acceptable one in which the relationship between linear and angular momenta is nevertheless more subtle and in which orbital and spin contributions emerge separately and with transparent forms.

  13. Form features provide a cue to the angular velocity of rotating objects

    PubMed Central

    Blair, Christopher David; Goold, Jessica; Killebrew, Kyle; Caplovitz, Gideon Paul

    2013-01-01

    As an object rotates, each location on the object moves with an instantaneous linear velocity dependent upon its distance from the center of rotation, while the object as a whole rotates with a fixed angular velocity. Does the perceived rotational speed of an object correspond to its angular velocity, linear velocities, or some combination of the two? We had observers perform relative speed judgments of different sized objects, as changing the size of an object changes the linear velocity of each location on the object’s surface, while maintaining the object’s angular velocity. We found that the larger a given object is, the faster it is perceived to rotate. However, the observed relationships between size and perceived speed cannot be accounted for simply by size-related changes in linear velocity. Further, the degree to which size influences perceived rotational speed depends on the shape of the object. Specifically, perceived rotational speeds of objects with corners or regions of high contour curvature were less affected by size. The results suggest distinct contour features, such as corners or regions of high or discontinuous contour curvature, provide cues to the angular velocity of a rotating object. PMID:23750970

  14. Form features provide a cue to the angular velocity of rotating objects.

    PubMed

    Blair, Christopher David; Goold, Jessica; Killebrew, Kyle; Caplovitz, Gideon Paul

    2014-02-01

    As an object rotates, each location on the object moves with an instantaneous linear velocity, dependent upon its distance from the center of rotation, whereas the object as a whole rotates with a fixed angular velocity. Does the perceived rotational speed of an object correspond to its angular velocity, linear velocities, or some combination of the two? We had observers perform relative speed judgments of different-sized objects, as changing the size of an object changes the linear velocity of each location on the object's surface, while maintaining the object's angular velocity. We found that the larger a given object is, the faster it is perceived to rotate. However, the observed relationships between size and perceived speed cannot be accounted for simply by size-related changes in linear velocity. Further, the degree to which size influences perceived rotational speed depends on the shape of the object. Specifically, perceived rotational speeds of objects with corners or regions of high-contour curvature were less affected by size. The results suggest distinct contour features, such as corners or regions of high or discontinuous contour curvature, provide cues to the angular velocity of a rotating object. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  15. Upper Limb Isokinetic Strengthening Versus Passive Mobilization in Patients With Chronic Stroke: A Randomized Controlled Trial.

    PubMed

    Coroian, Flavia; Jourdan, Claire; Bakhti, Karima; Palayer, Claire; Jaussent, Audrey; Picot, Marie-Christine; Mottet, Denis; Julia, Marc; Bonnin, Huey-Yune; Laffont, Isabelle

    2018-02-01

    To assess the benefit of isokinetic strengthening of the upper limb (UL) in patients with chronic stroke as compared to passive mobilization. Randomized blinded assessor controlled trial. Physical Medicine and Rehabilitation departments of 2 university hospitals. Patients (N=20) with incomplete hemiplegia (16 men; mean age, 64y; median time since stroke, 32mo). A 6-week comprehensive rehabilitation program, 3d/wk, 3 sessions/d. In addition, a 45-minute session per day was performed using an isokinetic dynamometer, with either isokinetic strengthening of elbow and wrist flexors/extensors (isokinetic strengthening group) or passive joint mobilization (control group). The primary endpoint was the increase in Upper Limb Fugl-Meyer Assessment (UL-FMA) score at day 45 (t1). Secondary endpoints were increases in UL-FMA scores, Box and Block Test scores, muscle strength, spasticity, and Barthel Index at t1, t2 (3mo), and t3 (6mo). Recruitment was stopped early because of excessive fatigue in the isokinetic strengthening group. The increase in UL-FMA score at t1 was 3.5±4.4 in the isokinetic strengthening group versus 6.0±4.5 in the control group (P=.2). Gains in distal UL-FMA scores were larger (3.1±2.8) in the control group versus 0.6±2.5 in the isokinetic strengthening group (P=.05). No significant group difference was observed in secondary endpoints. Mixed models confirmed those results. Regarding the whole sample, gains from baseline were significant for the UL-FMA at t1 (+4.8; P<.001), t2, and t3 and for the Box and Block Test at t1 (+3; P=.013) and t2. In a comprehensive rehabilitation program, isokinetic strengthening did not show superiority to passive mobilization for UL rehabilitation. Findings also suggest a sustained benefit in impairments and function of late UL rehabilitation programs for patients with stroke. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Isokinetic strength and endurance during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Bulbulian, R.; Bond, M.

    1994-01-01

    The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle ergometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.

  17. Isokinetic Strength and Endurance During 30-day 6 deg Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Bond, M.; Bulbulian, R.

    1994-01-01

    The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle orgometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.

  18. Selective hypertrophy of the quadriceps musculature after 14 weeks of isokinetic and conventional resistance training.

    PubMed

    Matta, Thiago Torres; Nascimento, Francisco Xavier; Trajano, Gabriel S; Simão, Roberto; Willardson, Jeffrey Michael; Oliveira, Liliam Fernandes

    2017-03-01

    One of the fundamental adaptations observed with resistance training (RT) is muscle hypertrophy. Conventional and isokinetic machines provide different forms of mechanical stress, and it is possible that these two training modes could promote differing degrees of hypertrophic adaptations. There is a lack of data comparing the selective hypertrophy of the quadriceps musculature after training with a conventional knee extension machine versus an isokinetic machine. The purpose of this study was to evaluate the selective hypertrophy of the quadriceps musculature and knee extension maximal isometric torque after 14 weeks of conventional versus isokinetic RT. Thirty-five men were assigned to three groups: control group and training groups (conventional and isokinetic) performed three sets of unilateral knee extensions per session with a progressive loading scheme twice a week. Prior to and following the intervention, maximal isometric knee extensor torque was measured using an isokinetic dynamometer, and muscle thickness (MT) of quadriceps femoris muscles was assessed via ultrasound. The results indicated non-uniform changes in MT between the muscles that comprise the quadriceps femoris group. For the conventional group, significantly greater increases in rectus femoris thickness were evident versus all other quadriceps muscles (14%). For the isokinetic group, increases in RF thickness (11%) were significantly greater in comparison with the vastus intermedius only. Although the muscle thickness did not increase for all the quadriceps femoris muscles, the relative rectus femoris adaptation suggested a selective hypertrophy favouring this portion. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  19. Mechanical and biomechanical analysis of a linear piston design for angular-velocity-based orthotic control.

    PubMed

    Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan

    2013-01-01

    A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.

  20. Modification of Impulse Generation During Pirouette Turns With Increased Rotational Demands.

    PubMed

    Zaferiou, Antonia M; Wilcox, Rand R; McNitt-Gray, Jill L

    2016-10-01

    This study determined how dancers regulated angular and linear impulse during the initiation of pirouettes of increased rotation. Skilled dancers (n = 11) performed single and double pirouette turns with each foot supported by a force plate. Linear and angular impulses generated by each leg were quantified and compared between turn types using probability-based statistical methods. As rotational demands increased, dancers increased the net angular impulse generated. The contribution of each leg to net angular impulse in both single and double pirouettes was influenced by stance configuration strategies. Dancers who generated more angular impulse with the push leg than with the turn leg initiated the turn with the center of mass positioned closer to the turn leg than did other dancers. As rotational demands increased, dancers tended to increase the horizontal reaction force magnitude at one or both feet; however, they used subject-specific mechanisms. By coordinating the generation of reaction forces between legs, changes in net horizontal impulse remained minimal, despite impulse regulation at each leg used to achieve more rotations. Knowledge gained regarding how an individual coordinates the generation of linear and angular impulse between both legs as rotational demand increased can help design tools to improve that individual's performance.

  1. Analysis of the association between isokinetic knee strength with offensive and defensive jumping capacity in high-level female volleyball athletes.

    PubMed

    Sattler, Tine; Sekulic, Damir; Esco, Michael R; Mahmutovic, Ifet; Hadzic, Vedran

    2015-09-01

    Isokinetic-knee-strength was hypothesized to be an important factor related to jumping performance. However, studies examining this relation among elite female athletes and sport-specific jumps are lacking. This investigation determined the influence of isokinetic-knee flexor/extensor strength measures on spike-jump (offensive) and block-jump (defensive) performance among high-level female volleyball players. Cross-sectional laboratory study. Eighty-two female volleyball athletes (age = 21.3 ± 3.8 years, height = 175.4 ± 6.76 cm, and weight = 68.29 ± 8.53 kg) volunteered to participate in this study. The studied variables included spike-jump and block-jump performance and a set of isokinetic tests to evaluate the eccentric and concentric strength capacities of the knee extensors (quadriceps - Q), and flexors (hamstring - H) for both legs. Both jumping tests showed high intra-session reliability (ICC of 0.87 and 0.95 for spike-jump and block-jump, respectively). The athletes were clustered into three achievement-groups based on their spike-jump and block-jump performances. For the block-jump, ANOVA identified significant differences between achievement-groups for all isokinetic variables except the Right-Q-Eccentric-Strength. When observed for spike-jump, achievement-groups differed significantly in all tests but Right-H-Concentric-Strength. Discriminant canonical analysis showed that the isokinetic-strength variables were more associated with block-jump then spike-jump-performance. The eccentric isokinetic measures were relatively less important determinants of block-jump than for the spike-jump performance. Data support the hypothesis of the importance of isokinetic strength measures for the expression of rapid muscular performance in volleyball. The results point to the necessity of the differential approach in sport training for defensive and offensive duties. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Isokinetic Leg Strength and Power in Elite Handball Players

    PubMed Central

    González-Ravé, José M.; Juárez, Daniel; Rubio-Arias, Jacobo A.; Clemente-Suarez, Vicente J; Martinez-Valencia, María A; Abian-Vicen, Javier

    2014-01-01

    Isokinetic strength evaluation of the knee flexion and extension in concentric mode of contraction is an important part of the comprehensive evaluation of athletes. The aims of this study were to evaluate the isokinetic knee peak torque in both the extension and flexion movement in the dominant and non-dominant leg, and the relationship with jumping performance. Twelve elite male handball players from the top Spanish handball division voluntary participated in the study (age 27.68 ± 4.12 years; body mass 92.89 ± 12.34 kg; body height 1.90 ± 0.05 m). The knee extensor and flexor muscle peak torque of each leg were concentrically measured at 60º/s and 180º/s with an isokinetic dynamometer. The Squat Jump and Countermovement Jump were performed on a force platform to determine power and vertical jump height. Non-significant differences were observed between legs in the isokinetic knee extension (dominant= 2.91 ± 0.53 Nm/kg vs non-dominant = 2.70 ± 0.47 Nm/kg at 60º/s; dominant = 1.90 ± 0.31 Nm/kg vs non-dominant = 1.83 ± 0.29 Nm/kg at 180º/s) and flexion peak torques (dominant = 1.76 ± 0.29 Nm/kg vs non-dominant = 1.72 ± 0.39 Nm/kg at 60º/s; dominant = 1.30 ± 0.23 Nm/kg vs non-dominant = 1.27 ± 0.35 Nm/kg at 180º/s). Low and non-significant correlation coefficients were found between the isokinetic peak torques and vertical jumping performance (SJ = 31.21 ± 4.32 cm; CMJ = 35.89 ± 4.20 cm). Similar isokinetic strength was observed between the legs; therefore, no relationship was found between the isokinetic knee flexion and extension peak torques as well as vertical jumping performance in elite handball players. PMID:25114749

  3. Isokinetic leg strength and power in elite handball players.

    PubMed

    González-Ravé, José M; Juárez, Daniel; Rubio-Arias, Jacobo A; Clemente-Suarez, Vicente J; Martinez-Valencia, María A; Abian-Vicen, Javier

    2014-06-28

    Isokinetic strength evaluation of the knee flexion and extension in concentric mode of contraction is an important part of the comprehensive evaluation of athletes. The aims of this study were to evaluate the isokinetic knee peak torque in both the extension and flexion movement in the dominant and non-dominant leg, and the relationship with jumping performance. Twelve elite male handball players from the top Spanish handball division voluntary participated in the study (age 27.68 ± 4.12 years; body mass 92.89 ± 12.34 kg; body height 1.90 ± 0.05 m). The knee extensor and flexor muscle peak torque of each leg were concentrically measured at 60º/s and 180º/s with an isokinetic dynamometer. The Squat Jump and Countermovement Jump were performed on a force platform to determine power and vertical jump height. Non-significant differences were observed between legs in the isokinetic knee extension (dominant= 2.91 ± 0.53 Nm/kg vs non-dominant = 2.70 ± 0.47 Nm/kg at 60º/s; dominant = 1.90 ± 0.31 Nm/kg vs non-dominant = 1.83 ± 0.29 Nm/kg at 180º/s) and flexion peak torques (dominant = 1.76 ± 0.29 Nm/kg vs non-dominant = 1.72 ± 0.39 Nm/kg at 60º/s; dominant = 1.30 ± 0.23 Nm/kg vs non-dominant = 1.27 ± 0.35 Nm/kg at 180º/s). Low and non-significant correlation coefficients were found between the isokinetic peak torques and vertical jumping performance (SJ = 31.21 ± 4.32 cm; CMJ = 35.89 ± 4.20 cm). Similar isokinetic strength was observed between the legs; therefore, no relationship was found between the isokinetic knee flexion and extension peak torques as well as vertical jumping performance in elite handball players.

  4. A Very Fast and Angular Momentum Conserving Tree Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcello, Dominic C., E-mail: dmarce504@gmail.com

    There are many methods used to compute the classical gravitational field in astrophysical simulation codes. With the exception of the typically impractical method of direct computation, none ensure conservation of angular momentum to machine precision. Under uniform time-stepping, the Cartesian fast multipole method of Dehnen (also known as the very fast tree code) conserves linear momentum to machine precision. We show that it is possible to modify this method in a way that conserves both angular and linear momenta.

  5. Analysis of Ballast Water Sampling Port Designs Using Computational Fluid Dynamics

    DTIC Science & Technology

    2008-02-01

    straight, vertical, upward-flowing pipe having a sample port diameter between 1.5 and 2.0 times the basic isokinetic diameter as defined in this report...water, flow modeling, sample port, sample pipe, particle trajectory, isokinetic sampling 18. Distribution Statement This document is available to...2.0 times the basic isokinetic diameter as defined in this report. Sample ports should use ball valves for isolation purposes and diaphragm or

  6. [Isokinetic testing of the shoulder of handball players].

    PubMed

    Michael, J W-P; König, D P; Bertram, C; Hessling, U; Eysel, P

    2005-09-01

    Aim of the study was to evaluate an isokinetic profile testing handball players to describe muscular imbalance. 30 athletes (15 male and 15 female) were measured at the Cybex 6000 test-unit for concentric internal and external rotation. Both shoulders, throwing arm (dominant shoulder) and the opposite shoulder were tested by speeds at 60 degrees/s and 180 degrees/s. There were sex specific differences which are also found in other sports. But these contrary data are not useful to define effective training concepts for handball-players with shoulder problems. From our point of view isokinetic testing of the shoulder joint in handball players can not reach any sufficient result. From our point of view there is no reason for using isokinetic testing to evaluate shoulder problems.

  7. Shoulder Rotator Muscle Dynamometry Characteristics: Side Asymmetry and Correlations with Ball-Throwing Speed in Adolescent Handball Players

    PubMed Central

    Pontaga, Inese; Zidens, Janis

    2014-01-01

    The aim of the investigation was to: 1) compare shoulder external/internal rotator muscles’ peak torques and average power values and their ratios in the dominant and non-dominant arm; 2) determine correlations between shoulder rotator muscles’ peak torques, average power and ball-throwing speed in handball players. Fourteen 14 to 15-year-old male athletes with injury-free shoulders participated in the study (body height: 176 ± 7 cm, body mass 63 ± 9 kg). The tests were carried out by an isokinetic dynamometer system in the shoulder internal and external rotation movements at angular velocities of 60°/s, 90°/s and 240°/s during concentric contractions. The eccentric external– concentric internal rotator muscle contractions were performed at the velocity of 90°/s. The player threw a ball at maximal speed keeping both feet on the floor. The speed was recorded with reflected light rays. Training in handball does not cause significant side asymmetry in shoulder external/internal rotator muscle peak torques or the average power ratio. Positive correlations between isokinetic characteristics of the shoulder internal and external rotator muscles and ball-throwing speed were determined. The power produced by internal rotator muscles during concentric contractions after eccentric contractions of external rotator muscles was significantly greater in the dominant than in the non-dominant arm. Thus, it may be concluded that the shoulder eccentric external/concentric internal rotator muscle power ratio is significantly greater than this ratio in the concentric contractions of these muscles. PMID:25414738

  8. Angular Impact Mitigation System for Bicycle Helmets to Reduce Head Acceleration and Risk of Traumatic Brain Injury

    PubMed Central

    Hansen, Kirk; Dau, Nathan; Feist, Florian; Deck, Caroline; Willinger, Rémy; Madey, Steven M.; Bottlang, Michael

    2013-01-01

    Angular acceleration of the head is a known cause of traumatic brain injury (TBI), but contemporary bicycle helmets lack dedicated mechanisms to mitigate angular acceleration. A novel Angular Impact Mitigation (AIM) system for bicycle helmets has been developed that employs an elastically suspended aluminum honeycomb liner to absorb linear acceleration in normal impacts as well as angular acceleration in oblique impacts. This study tested bicycle helmets with and without AIM technology to comparatively assess impact mitigation. Normal impact tests were performed to measure linear head acceleration. Oblique impact tests were performed to measure angular head acceleration and neck loading. Furthermore, acceleration histories of oblique impacts were analyzed in a computational head model to predict the resulting risk of TBI in the form of concussion and diffuse axonal injury (DAI). Compared to standard helmets, AIM helmets resulted in a 14% reduction in peak linear acceleration (p < 0.001), a 34% reduction in peak angular acceleration (p < 0.001), and a 22% to 32% reduction in neck loading (p < 0.001). Computational results predicted that AIM helmets reduced the risk of concussion and DAI by 27% and 44%, respectively. In conclusion, these results demonstrated that AIM technology could effectively improve impact mitigation compared to a contemporary expanded polystyrene-based bicycle helmet, and may enhance prevention of bicycle-related TBI. Further research is required. PMID:23770518

  9. Partial rupture of the pectoralis major muscle in athletes.

    PubMed

    Roi, G S; Respizzi, S; Dworzak, F

    1990-02-01

    Partial rupture of the pectoralis major muscle is quite a rare event in sports traumatology and information about its treatment is lacking in literature. In this paper the long term effect of conservative non-surgical treatment in two body-builders and one shot-putter is discussed, who reported the partial rupture while performing bench lifts with barbells. Functional recovery was evaluated a few years after the injury (from 4 to 7) with an isokinetic dynamometer (Cybex II, Lumex INC N.Y.), measuring maximal shoulder adduction-abduction torques at different angular speeds (60, 180, and 300 degrees/s). The results were compared with those of five healthy athletes practicing either body-building or weight-lifting. From the present study we conclude the following: the non-invasive treatment of a partial rupture of the pectoralis major muscle may produce almost complete functional recovery; in normal subjects adduction muscles are advantageous in comparison to the abduction ones.

  10. Aerosol Sampling: Comparison of Two Rotating Impactors for Field Droplet Sizing and Volumetric Measurements

    DTIC Science & Technology

    2009-01-01

    the rotating impactors were measured via spectroscopy and microscopy. The rotary impactors were colocated with an isokinetic air sampler for a total...diameter, and the 90% diameter (DV10 and DV90; ASTM 2004). For each replication, an isokinetic air sampler and rotary sampler operated simultaneously in the...working area of the dispersion tunnel. The isokinetic sampler (StaplexH Model TFIA High Volume Air Sampler, The Staplex Company, Brooklyn, NY) was

  11. Validity and reliability of isometric, isokinetic and isoinertial modalities for the assessment of quadriceps muscle strength in patients with total knee arthroplasty.

    PubMed

    Lienhard, K; Lauermann, S P; Schneider, D; Item-Glatthorn, J F; Casartelli, N C; Maffiuletti, N A

    2013-12-01

    Reliability of isometric, isokinetic and isoinertial modalities for quadriceps strength evaluation, and the relation between quadriceps strength and physical function was investigated in 29 total knee arthroplasty (TKA) patients, with an average age of 63 years. Isometric maximal voluntary contraction torque, isokinetic peak torque, and isoinertial one-repetition maximum load of the involved and uninvolved quadriceps were evaluated as well as objective (walking parameters) and subjective physical function (WOMAC). Reliability was good and comparable for the isometric, isokinetic, and isoinertial strength outcomes on both sides (intraclass correlation coefficient range: 0.947-0.966; standard error of measurement range: 5.1-9.3%). Involved quadriceps strength was significantly correlated to walking speed (r range: 0.641-0.710), step length (r range: 0.685-0.820) and WOMAC function (r range: 0.575-0.663), independent from the modality (P < 0.05). Uninvolved quadriceps strength was also significantly correlated to walking speed (r range: 0.413-0.539), step length (r range: 0.514-0.608) and WOMAC function (r range: 0.374-0.554) (P < 0.05), except for WOMAC function/isokinetic peak torque (P > 0.05). In conclusion, isometric, isokinetic, and isoinertial modalities ensure valid and reliable assessment of quadriceps muscle strength in TKA patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Muscle recruitment patterns of the subscapularis, serratus anterior and other shoulder girdle muscles during isokinetic internal and external rotations.

    PubMed

    Gaudet, Sylvain; Tremblay, Jonathan; Begon, Mickael

    2018-05-01

    The aims of this study were to investigate the differences in peak muscle activity and recruitment patterns during high- and low-velocity, concentric and eccentric, internal and external isokinetic shoulder rotations. Electromyographic activity of the rotator cuff and eight superficial muscles of the shoulder girdle was recorded on 25 healthy adults during isokinetic internal and external shoulder rotation at 60°/s and 240°/s. Peak muscle activity, electromyographic envelopes and peak isokinetic moments were analyzed using three-factor ANOVA and statistical parametric mapping. The subscapularis and serratus anterior showed moderate to high peak activity levels during each conditions, while the middle and posterior deltoids, upper, middle and lower trapezius, infraspinatus and supraspinatus showed higher peak activity levels during external rotations (+36.5% of maximum voluntary activation (MVA)). The pectoralis major and latissimus dorsi were more active during internal rotations (+40% of MVA). Only middle trapezius and pectoralis major electromyographic activity decreased with increasing velocity. Peak muscle activity was similar or lower during eccentric contractions, although the peak isokinetic moment increased by 35% on average. The subscapularis and serratus anterior appear to be important stabilizers of the glenohumeral joint and scapula. Isokinetic eccentric training at high velocities may allow for faster recruitment of the shoulder girdle muscles, which could improve joint stability during shoulder internal and external rotations.

  13. Relative differences in strength and power from slow to fast isokinetic velocities may reflect dynapenia.

    PubMed

    Jenkins, Nathaniel D M; Housh, Terry J; Palmer, Ty B; Cochrane, Kristen C; Bergstrom, Haley C; Johnson, Glen O; Schmidt, Richard J; Cramer, Joel T

    2015-07-01

    We compared absolute and normalized values for peak torque (PT), mean power (MP), rate of velocity development, and electromyography (EMG) amplitude during maximal isometric and concentric isokinetic leg extension muscle actions, as well as the %decrease in PT and %increase in MP from 1.05 to 3.14 rad·s(-1) in younger versus older men. Measurements were performed twice for reliability. Isokinetic measurements were normalized to the isometric muscle actions. Absolute isometric PT, isokinetic PT and MP, and EMG amplitudes at 1.05 and 3.14 rad·s(-1) were greater in the younger men, although normalizing to isometric PT eliminated the age differences. The older men exhibited greater %decrease in PT (37.2% vs. 31.3%) and lower %increase in MP (87.6% vs. 126.4%) regardless of normalization. Normalization eliminated absolute differences in isokinetic strength and power, but the relative differences from slow to fast velocities may reflect dynapenia characterized by age-related decreases in fast-twitch fiber function. © 2014 Wiley Periodicals, Inc.

  14. Effects of the application of ankle functional rehabilitation exercise on the ankle joint functional movement screen and isokinetic muscular function in patients with chronic ankle sprain.

    PubMed

    Ju, Sung-Bum; Park, Gi Duck

    2017-02-01

    [Purpose] This study was conducted to investigate the effects of ankle functional rehabilitation exercise on ankle joint functional movement screen results and isokinetic muscular function in patients with chronic ankle sprain patients. [Subjects and Methods] In this study, 16 patients with chronic ankle sprain were randomized to an ankle functional rehabilitation exercise group (n=8) and a control group (n=8). The ankle functional rehabilitation exercise centered on a proprioceptive sense exercise program, which was applied 12 times for 2 weeks. To verify changes after the application, ankle joint functional movement screen scores and isokinetic muscular function were measured and analyzed. [Results] The ankle functional rehabilitation exercise group showed significant improvements in all items of the ankle joint functional movement screen and in isokinetic muscular function after the exercise, whereas the control group showed no difference after the application. [Conclusion] The ankle functional rehabilitation exercise program can be effectively applied in patients with chronic ankle sprain for the improvement of ankle joint functional movement screen score and isokinetic muscular function.

  15. Effects of the application of ankle functional rehabilitation exercise on the ankle joint functional movement screen and isokinetic muscular function in patients with chronic ankle sprain

    PubMed Central

    Ju, Sung-Bum; Park, Gi Duck

    2017-01-01

    [Purpose] This study was conducted to investigate the effects of ankle functional rehabilitation exercise on ankle joint functional movement screen results and isokinetic muscular function in patients with chronic ankle sprain patients. [Subjects and Methods] In this study, 16 patients with chronic ankle sprain were randomized to an ankle functional rehabilitation exercise group (n=8) and a control group (n=8). The ankle functional rehabilitation exercise centered on a proprioceptive sense exercise program, which was applied 12 times for 2 weeks. To verify changes after the application, ankle joint functional movement screen scores and isokinetic muscular function were measured and analyzed. [Results] The ankle functional rehabilitation exercise group showed significant improvements in all items of the ankle joint functional movement screen and in isokinetic muscular function after the exercise, whereas the control group showed no difference after the application. [Conclusion] The ankle functional rehabilitation exercise program can be effectively applied in patients with chronic ankle sprain for the improvement of ankle joint functional movement screen score and isokinetic muscular function. PMID:28265157

  16. Torque, power and muscle activation of eccentric and concentric isokinetic cycling.

    PubMed

    Green, David J; Thomas, Kevin; Ross, Emma Z; Green, Steven C; Pringle, Jamie S M; Howatson, Glyn

    2018-06-01

    This study aimed to establish the effect of cycling mode and cadence on torque, external power output, and lower limb muscle activation during maximal, recumbent, isokinetic cycling. After familiarisation, twelve healthy males completed 6 × 10 s of maximal eccentric (ECC) and concentric (CON) cycling at 20, 40, 60, 80, 100, and 120 rpm with five minutes recovery. Vastus lateralis, medial gastrocnemius, rectus femoris, and biceps femoris surface electromyography was recorded throughout. As cadence increased, peak torque linearly decreased during ECC (350-248 N·m) and CON (239-117 N·m) and peak power increased in a parabolic manner. Crank angle at peak torque increased with cadence in CON (+13°) and decreased in ECC (-9.0°). At all cadences, peak torque (mean +129 N·m, range 111-143 N·m), and power (mean +871 W, range 181-1406 W), were greater during ECC compared to CON. For all recorded muscles the crank angle at peak muscle activation was greater during ECC compared to CON. This difference increased with cadence in all muscles except the vastus lateralis. Additionally, peak vastus laterallis and biceps femoris activation was greater during CON compared to ECC. Eccentric cycling offers a greater mechanical stimulus compared to concentric cycling but the effect of cadence is similar between modalities. Markers of technique (muscle activation, crank angle at peak activation and torque) were different between eccentric and concentric cycling and respond differently to changes in cadence. Such data should be considered when comparing between, and selecting cadences for, recumbent, isokinetic, eccentric and concentric cycling. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  17. Isokinetic trunk muscle performance in pre-teens and teens with and without back pain.

    PubMed

    Bernard, J-C; Boudokhane, S; Pujol, A; Chaléat-Valayer, E; Le Blay, G; Deceuninck, J

    2014-02-01

    To assess with an isokinetic dynamometer the force and endurance of the spinal flexor and extensor muscles in pre-teens or teens aged 11 to 13 and 14 to 16 years with and without low back pain (LBP). The control group and the LBP group were homogeneous in terms of age, weight, height and Body Mass Index (BMI). Assessment was carried out with the isokinetic dynamometer Cybex Norm®. The spinal flexors and extensors were explored concentrically at speeds of 60°, 90° and 120°/sec. The parameters chosen were: maximal moment of force (MMF), mean power (MP), total work (TW), F/E ratios (between the flexors and the extensors for the aforesaid parameters). In the LBP groups, clinical information (pain, extensibility of the spinal and sub-pelvic muscles, sports practice) and sagittal radiological data were all measured. While no significant difference in isokinetic performance was found between asymptomatic and LBP children in the 11-to-13-year-old group, the isokinetic performances of the LBP children were influenced positively by BMI value, number of hours of physical activity and radiologic value of the lumbar lordosis. As regards these pre-teens, assessment with an isokinetic dynamometer does not highlight muscle characteristics that might explain LBP occurrence. As regards the 14-to-16-year-old group, muscle strength has been found to be correlated with age. LBP teens were showed to have weaker extensors and stronger flexors than the healthy teens. It is with regard to this age group that assessment with an isokinetic dynamometer clearly yields interesting results. Since we have yet to standardize our evaluation criteria (working speed, number of trials…), it is difficult to compare our results with those reported in the literature. This is a preliminary study involving a relatively low number of patients. That said, given the fact that numerous parameters are connected with the age and height of the subjects, assessment with an isokinetic dynamometer can be constructively carried out from the age of 14. In order to further enhance understanding of this phenomenon, a longitudinal and comparative study of a larger group is needed. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Isometric and isokinetic muscle strength in the upper extremity can be reliably measured in persons with chronic stroke.

    PubMed

    Ekstrand, Elisabeth; Lexell, Jan; Brogårdh, Christina

    2015-09-01

    To evaluate the test-retest reliability of isometric and isokinetic muscle strength measurements in the upper extremity after stroke. A test-retest design. Forty-five persons with mild to moderate paresis in the upper extremity > 6 months post-stroke. Isometric arm strength (shoulder abduction, elbow flexion), isokinetic arm strength (elbow extension/flexion) and isometric grip strength were measured with electronic dynamometers. Reliability was evaluated with intra-class correlation coefficients (ICC), changes in the mean, standard error of measurements (SEM) and smallest real differences (SRD). Reliability was high (ICCs: 0.92-0.97). The absolute and relative (%) SEM ranged from 2.7 Nm (5.6%) to 3.0 Nm (9.4%) for isometric arm strength, 2.6 Nm (7.4%) to 2.9 Nm (12.6%) for isokinetic arm strength, and 22.3 N (7.6%) to 26.4 N (9.2%) for grip strength. The absolute and relative (%) SRD ranged from 7.5 Nm (15.5%) to 8.4 Nm (26.1%) for isometric arm strength, 7.1 Nm (20.6%) to 8.0 Nm (34.8%) for isokinetic arm strength, and 61.8 N (21.0%) to 73.3 N (25.6%) for grip strength. Muscle strength in the upper extremity can be reliably measured in persons with chronic stroke. Isometric measurements yield smaller measurement errors than isokinetic measurements and might be preferred, but the choice depends on the research question.

  19. RadioAstron Maser Observations: a Record in Angular Resolution

    NASA Astrophysics Data System (ADS)

    Sobolev, A. M.; Shakhvorostova, N. N.; Alakoz, A. V.; Baan, W. A.; RadioAstron Maser Team

    2017-06-01

    Extremely long baselines of the space-ground interferometer RadioAstron allow to achieve ultra-high angular resolutions. The possibility of detection of a maser emission with resolutions about tens of micro-arcseconds was arguable before successful experiments reported in this paper. We present the results of the maser survey obtained by RadioAstron during first 5 years of operation. Extremely high angular resolution of 11 microarcseconds have been achieved in observations of the megamaser galaxy NGC 4258. For the galaxy at the distance about 7 Mpc this corresponds to linear resolution around 80 AU. Very compact features with angular sizes about 20 micro-arcseconds have been detected in star-forming regions of our Galaxy. Corresponding linear sizes are about 5-10 millions of kilometers.

  20. Isokinetic knee strength qualities as predictors of jumping performance in high-level volleyball athletes: multiple regression approach.

    PubMed

    Sattler, Tine; Sekulic, Damir; Spasic, Miodrag; Osmankac, Nedzad; Vicente João, Paulo; Dervisevic, Edvin; Hadzic, Vedran

    2016-01-01

    Previous investigations noted potential importance of isokinetic strength in rapid muscular performances, such as jumping. This study aimed to identify the influence of isokinetic-knee-strength on specific jumping performance in volleyball. The secondary aim of the study was to evaluate reliability and validity of the two volleyball-specific jumping tests. The sample comprised 67 female (21.96±3.79 years; 68.26±8.52 kg; 174.43±6.85 cm) and 99 male (23.62±5.27 years; 84.83±10.37 kg; 189.01±7.21 cm) high- volleyball players who competed in 1st and 2nd National Division. Subjects were randomly divided into validation (N.=55 and 33 for males and females, respectively) and cross-validation subsamples (N.=54 and 34 for males and females, respectively). Set of predictors included isokinetic tests, to evaluate the eccentric and concentric strength capacities of the knee extensors, and flexors for dominant and non-dominant leg. The main outcome measure for the isokinetic testing was peak torque (PT) which was later normalized for body mass and expressed as PT/Kg. Block-jump and spike-jump performances were measured over three trials, and observed as criteria. Forward stepwise multiple regressions were calculated for validation subsamples and then cross-validated. Cross validation included correlations between and t-test differences between observed and predicted scores; and Bland Altman graphics. Jumping tests were found to be reliable (spike jump: ICC of 0.79 and 0.86; block-jump: ICC of 0.86 and 0.90; for males and females, respectively), and their validity was confirmed by significant t-test differences between 1st vs. 2nd division players. Isokinetic variables were found to be significant predictors of jumping performance in females, but not among males. In females, the isokinetic-knee measures were shown to be stronger and more valid predictors of the block-jump (42% and 64% of the explained variance for validation and cross-validation subsample, respectively) than that of the spike-jump (39% and 34% of the explained variance for validation and cross-validation subsample, respectively). Differences between prediction models calculated for males and females are mostly explained by gender-specific biomechanics of jumping. Study defined importance of knee-isokinetic-strength in volleyball jumping performance in female athletes. Further studies should evaluate association between ankle-isokinetic-strength and volleyball-specific jumping performances. Results reinforce the need for the cross-validation of the prediction-models in sport and exercise sciences.

  1. Anaerobic Work Capacity derived from isokinetic and isoinertial cycling.

    PubMed

    Wiedemann, M S F; Bosquet, L

    2010-02-01

    The purpose of this study was to compare Anaerobic Work Capacity (AWC) measured on an isoinertial or an isokinetic bicycle ergometer. Twelve male participants completed two randomly ordered exercise testing sessions including a torque-velocity test followed by a 30-s all-out test on an isokinetic ergometer, or a force-velocity test followed by a Wingate Anaerobic Test on an isoinertial ergometer. Optimal load measured during the force-velocity test on the isoinertial ergometer was 1.13+/-0.11 N.kg(-1). Optimal cadence measured during the torque-velocity test on the isokinetic ergometer was 107+/-13 rpm. Although P(peak) measures were significantly correlated (r=0.77), we found a large difference between them (effect size=2.85) together with wide limits of agreement (bias+/-95%LOA=24+/-12%). The same observation was made with P(mean), but with a smaller magnitude of difference (bias+/-95%LOA=4.2+/-12%; effect size=0.51; r=0.73). This lack of agreement led us to the conclusion that AWC measures obtained during 30-s all-out tests performed on an isoinertial or an isokinetic bicycle ergometer are not necessarily similar and cannot be used interchangeably.

  2. Modeling hardwood crown radii using circular data analysis

    Treesearch

    Paul F. Doruska; Hal O. Liechty; Douglas J. Marshall

    2003-01-01

    Cylindrical data are bivariate data composed of a linear and an angular component. One can use uniform, first-order (one maximum and one minimum) or second-order (two maxima and two minima) models to relate the linear component to the angular component. Crown radii can be treated as cylindrical data when the azimuths at which the radii are measured are also recorded....

  3. [Absolute and relative strength-endurance of the knee flexor and extensor muscles: a reliability study using the IsoMed 2000-dynamometer].

    PubMed

    Dirnberger, J; Wiesinger, H P; Stöggl, T; Kösters, A; Müller, E

    2012-09-01

    Isokinetic devices are highly rated in strength-related performance diagnosis. A few years ago, the broad variety of existing products was extended by the IsoMed 2000-dynamometer. In order for an isokinetic device to be clinically useful, the reliability of specific applications must be established. Although there have already been single studies on this topic for the IsoMed 2000 concerning maximum strength measurements, there has been no study regarding the assessment of strength-endurance so far. The aim of the present study was to establish the reliability for various methods of quantification of strength-endurance using the IsoMed 2000. A sample of 33 healthy young subjects (age: 23.8 ± 2.6 years) participated in one familiarisation and two testing sessions, 3-4 days apart. Testing consisted of a series 30 full effort concentric extension-flexion cycles of the right knee muscles at an angular velocity of 180 °/s. Based on the parameters Peak, Torque and Work for each repetition, indices of absolute (KADabs) and relative (KADrel) strength-endurance were derived. KADabs was calculated as the mean value of all testing repetitions, KADrel was determined in two ways: on the one hand, as the percentage decrease between the first and the last 5 repetitions (KADrelA) and on the other, as the negative slope derived from the linear regression equitation of all repetitions (KADrelB). Detection of systematic errors was performed using paired sample t-tests, relative and absolute reliability were examined using intraclass correlation coefficient (ICC 2.1) and standard error of measurement (SEM%), respectively. In general, for extension measurements concerning KADabs and - in an weakened form - KADrel high ICC -values of 0.76-0.89 combined with clinically acceptable values of SEM% of 1.2-5.9 % could be found. For flexion measurements this only applies to KADabs, whereas results for KADrel turned out to be clearly weaker with ICC- and SEM% values of 0.42-0.62 and 9.6-17.7 % and leave considerable doubts on the clinical usefulness. However, if there should be after all a need to measure KADrel for flexion, it is - in view of the stronger reliability results - recommended (i) to concentrate on the calculation of KADrelB, (ii) to use the parameter Work and - in view of considerable familiariszation and learning effects of ≈10 % - (iii) to include a familiarisation period that extends exceeds the familiarisation session conducted in the present study. Georg Thieme Verlag KG Stuttgart · New York.

  4. Validation of a Compact Isokinetic Total Water Content Probe for Wind Tunnel Characterization at NASA Glenn Icing Research Tunnel and at NRC Ice Crystal Tunnel

    NASA Technical Reports Server (NTRS)

    Davison, Craig R.; Landreville, Charles; Ratvasky, Thomas P.

    2017-01-01

    A new compact isokinetic probe to measure total water content in a wind tunnel environment has been developed. The probe has been previously tested under altitude conditions. This paper presents a comprehensive validation of the probe under a range of liquid water conditions at sea level in the NASA Glenn Icing Research Tunnel and with ice crystals at sea level at the NRC wind tunnel. The compact isokinetic probe is compared to tunnel calibrations and other probes.

  5. Isokinetic air sampler

    DOEpatents

    Sehmel, George A.

    1979-01-01

    An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

  6. Using Evolved Fuzzy Neural Networks for Injury Detection from Isokinetic Curves

    NASA Astrophysics Data System (ADS)

    Couchet, Jorge; Font, José María; Manrique, Daniel

    In this paper we propose an evolutionary fuzzy neural networks system for extracting knowledge from a set of time series containing medical information. The series represent isokinetic curves obtained from a group of patients exercising the knee joint on an isokinetic dynamometer. The system has two parts: i) it analyses the time series input in order generate a simplified model of an isokinetic curve; ii) it applies a grammar-guided genetic program to obtain a knowledge base represented by a fuzzy neural network. Once the knowledge base has been generated, the system is able to perform knee injuries detection. The results suggest that evolved fuzzy neural networks perform better than non-evolutionary approaches and have a high accuracy rate during both the training and testing phases. Additionally, they are robust, as the system is able to self-adapt to changes in the problem without human intervention.

  7. Reliability of a Novel High Intensity One Leg Dynamic Exercise Protocol to Measure Muscle Endurance

    PubMed Central

    Lepers, Romuald; Marcora, Samuele M.

    2016-01-01

    We recently developed a high intensity one leg dynamic exercise (OLDE) protocol to measure muscle endurance and investigate the central and peripheral mechanisms of muscle fatigue. The aims of the present study were to establish the reliability of this novel protocol and describe the isokinetic muscle fatigue induced by high intensity OLDE and its recovery. Eight subjects performed the OLDE protocol (time to exhaustion test of the right leg at 85% of peak power output) three times over a week period. Isokinetic maximal voluntary contraction torque at 60 (MVC60), 100 (MVC100) and 140 (MVC140) deg/s was measured pre-exercise, shortly after exhaustion (13 ± 4 s), 20 s (P20) and 40 s (P40) post-exercise. Electromyographic (EMG) signal was analyzed via the root mean square (RMS) for all three superficial knee extensors. Mean time to exhaustion was 5.96 ± 1.40 min, coefficient of variation was 8.42 ± 6.24%, typical error of measurement was 0.30 min and intraclass correlation was 0.795. MVC torque decreased shortly after exhaustion for all angular velocities (all P < 0.001). MVC60 and MVC100 recovered between P20 (P < 0.05) and exhaustion and then plateaued. MVC140 recovered only at P40 (P < 0.05). High intensity OLDE did not alter maximal EMG RMS of the three superficial knee extensors during MVC. The results of this study demonstrate that this novel high intensity OLDE protocol could be reliably used to measure muscle endurance, and that muscle fatigue induced by high intensity OLDE should be examined within ~ 30 s following exhaustion. PMID:27706196

  8. Space Mirror Alignment System

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.; McKinney, Colin; Smythe, Robert F.; Palmer, Dean L.

    2011-01-01

    An optical alignment mirror mechanism (AMM) has been developed with angular positioning accuracy of +/-0.2 arcsec. This requires the mirror s linear positioning actuators to have positioning resolutions of +/-112 nm to enable the mirror to meet the angular tip/tilt accuracy requirement. Demonstrated capabilities are 0.1 arc-sec angular mirror positioning accuracy, which translates into linear positioning resolutions at the actuator of 50 nm. The mechanism consists of a structure with sets of cross-directional flexures that enable the mirror s tip and tilt motion, a mirror with its kinematic mount, and two linear actuators. An actuator comprises a brushless DC motor, a linear ball screw, and a piezoelectric brake that holds the mirror s position while the unit is unpowered. An interferometric linear position sensor senses the actuator s position. The AMMs were developed for an Astrometric Beam Combiner (ABC) optical bench, which is part of an interferometer development. Custom electronics were also developed to accommodate the presence of multiple AMMs within the ABC and provide a compact, all-in-one solution to power and control the AMMs.

  9. Canal–Otolith Interactions and Detection Thresholds of Linear and Angular Components During Curved-Path Self-Motion

    PubMed Central

    MacNeilage, Paul R.; Turner, Amanda H.

    2010-01-01

    Gravitational signals arising from the otolith organs and vertical plane rotational signals arising from the semicircular canals interact extensively for accurate estimation of tilt and inertial acceleration. Here we used a classical signal detection paradigm to examine perceptual interactions between otolith and horizontal semicircular canal signals during simultaneous rotation and translation on a curved path. In a rotation detection experiment, blindfolded subjects were asked to detect the presence of angular motion in blocks where half of the trials were pure nasooccipital translation and half were simultaneous translation and yaw rotation (curved-path motion). In separate, translation detection experiments, subjects were also asked to detect either the presence or the absence of nasooccipital linear motion in blocks, in which half of the trials were pure yaw rotation and half were curved path. Rotation thresholds increased slightly, but not significantly, with concurrent linear velocity magnitude. Yaw rotation detection threshold, averaged across all conditions, was 1.45 ± 0.81°/s (3.49 ± 1.95°/s2). Translation thresholds, on the other hand, increased significantly with increasing magnitude of concurrent angular velocity. Absolute nasooccipital translation detection threshold, averaged across all conditions, was 2.93 ± 2.10 cm/s (7.07 ± 5.05 cm/s2). These findings suggest that conscious perception might not have independent access to separate estimates of linear and angular movement parameters during curved-path motion. Estimates of linear (and perhaps angular) components might instead rely on integrated information from canals and otoliths. Such interaction may underlie previously reported perceptual errors during curved-path motion and may originate from mechanisms that are specialized for tilt-translation processing during vertical plane rotation. PMID:20554843

  10. A dual-heterodyne laser interferometer for simultaneous measurement of linear and angular displacements.

    PubMed

    Yan, Hao; Duan, Hui-Zong; Li, Lin-Tao; Liang, Yu-Rong; Luo, Jun; Yeh, Hsien-Chi

    2015-12-01

    Picometer laser interferometry is an essential tool for ultra-precision measurements in frontier scientific research and advanced manufacturing. In this paper, we present a dual-heterodyne laser interferometer for simultaneously measuring linear and angular displacements with resolutions of picometer and nanoradian, respectively. The phase measurement method is based on cross-correlation analysis and realized by a PXI-bus data acquisition system. By implementing a dual-heterodyne interferometer with a highly symmetric optical configuration, low frequency noises caused by the environmental fluctuations can be suppressed to very low levels via common-mode noise rejection. Experimental results for the dual-heterodyne interferometer configuration presented demonstrate that the noise levels of the linear and angular displacement measurements are approximately 1 pm/Hz(1/2) and 0.5 nrad/Hz(1/2) at 1 Hz.

  11. Hybrid 3-D rocket trajectory program. Part 1: Formulation and analysis. Part 2: Computer programming and user's instruction. [computerized simulation using three dimensional motion analysis

    NASA Technical Reports Server (NTRS)

    Huang, L. C. P.; Cook, R. A.

    1973-01-01

    Models utilizing various sub-sets of the six degrees of freedom are used in trajectory simulation. A 3-D model with only linear degrees of freedom is especially attractive, since the coefficients for the angular degrees of freedom are the most difficult to determine and the angular equations are the most time consuming for the computer to evaluate. A computer program is developed that uses three separate subsections to predict trajectories. A launch rail subsection is used until the rocket has left its launcher. The program then switches to a special 3-D section which computes motions in two linear and one angular degrees of freedom. When the rocket trims out, the program switches to the standard, three linear degrees of freedom model.

  12. Creating optical near-field orbital angular momentum in a gold metasurface.

    PubMed

    Chen, Ching-Fu; Ku, Chen-Ta; Tai, Yi-Hsin; Wei, Pei-Kuen; Lin, Heh-Nan; Huang, Chen-Bin

    2015-04-08

    Nanocavities inscribed in a gold thin film are optimized and designed to form a metasurface. We demonstrate both numerically and experimentally the creation of surface plasmon (SP) vortex carrying orbital angular momentum in the metasurface under linearly polarized optical excitation that carries no optical angular momentum. Moreover, depending on the orientation of the exciting linearly polarized light, we show that the metasurface is capable of providing dynamic switching between SP vortex formation or SP subwavelength focusing. The resulting SP intensities are experimentally measured using a near-field scanning optical microscope and are found in excellent quantitative agreements as compared to the numerical results.

  13. Asymmetries and three-dimensional features of vestibular cross-coupled stimuli illuminated through modeling

    PubMed Central

    Holly, Jan E.; Masood, M. Arjumand; Bhandari, Chiran S.

    2017-01-01

    Head movements during sustained rotation can cause angular cross-coupling which leads to tumbling illusions. Even though angular vectors predict equal magnitude illusions for head movements in opposite directions, the magnitudes of the illusions are often surprisingly asymmetric, such as during leftward versus rightward yaw while horizontal in a centrifuge. This paper presents a comprehensive investigation of the angular-linear stimulus combinations from eight different published papers in which asymmetries were found. Interactions between all angular and linear vectors, including gravity, are taken into account to model the three-dimensional consequences of the stimuli. Three main results followed. First, for every pair of head yaw movements, an asymmetry was found in the stimulus itself when considered in a fully three-dimensional manner, and the direction of the asymmetry matched the subjectively reported magnitude asymmetry. Second, for pitch and roll head movements for which motion sickness was measured, the stimulus was found symmetric in every case except one, and motion sickness generally aligned with other factors such as the existence of a head rest. Third, three-dimensional modeling predicted subjective inconsistency in the direction of perceived rotation when linear and angular components were oppositely-directed, and predicted surplus illusory rotation in the direction of head movement. PMID:27814310

  14. Angular-momentum-assisted dissociation of CO in strong optical fields

    NASA Astrophysics Data System (ADS)

    Mullin, Amy; Ogden, Hannah; Murray, Matthew; Liu, Qingnan; Toro, Carlos

    2017-04-01

    Filaments are produced in CO gas by intense, chirped laser pulses. Visible emission from C2 is observed as a result of chemical reactions of highly excited CO. At laser intensities greater than 1014 W cm-2, the C2 emission shows a strong dependence on laser polarization. Oppositely chirped pulses of light with ω0 = 800 nm are recombined spatially and temporally to generate angularly accelerating electric fields (up to 30 THz) that either have an instantaneous linear polarization or act as a dynamic polarization grating that oscillates among linear and circular polarizations. The angularly accelerating linear polarization corresponds to an optical centrifuge that concurrently drives molecules into high rotational states (with J 50) and induces strong-field dissociation. Higher order excitation is observed for the time-varying laser polarization configuration that does not induce rotational excitation. The results indicate that the presence of rotational angular momentum lowers the threshold for CO dissociation in strong optical fields by coupling nuclear and electronic degrees of freedom. Support from NSF CHE-1058721 and the University of Maryland.

  15. Hydrodynamic turbulence cannot transport angular momentum effectively in astrophysical disks.

    PubMed

    Ji, Hantao; Burin, Michael; Schartman, Ethan; Goodman, Jeremy

    2006-11-16

    The most efficient energy sources known in the Universe are accretion disks. Those around black holes convert 5-40 per cent of rest-mass energy to radiation. Like water circling a drain, inflowing mass must lose angular momentum, presumably by vigorous turbulence in disks, which are essentially inviscid. The origin of the turbulence is unclear. Hot disks of electrically conducting plasma can become turbulent by way of the linear magnetorotational instability. Cool disks, such as the planet-forming disks of protostars, may be too poorly ionized for the magnetorotational instability to occur, and therefore essentially unmagnetized and linearly stable. Nonlinear hydrodynamic instability often occurs in linearly stable flows (for example, pipe flows) at sufficiently large Reynolds numbers. Although planet-forming disks have extreme Reynolds numbers, keplerian rotation enhances their linear hydrodynamic stability, so the question of whether they can be turbulent and thereby transport angular momentum effectively is controversial. Here we report a laboratory experiment, demonstrating that non-magnetic quasi-keplerian flows at Reynolds numbers up to millions are essentially steady. Scaled to accretion disks, rates of angular momentum transport lie far below astrophysical requirements. By ruling out purely hydrodynamic turbulence, our results indirectly support the magnetorotational instability as the likely cause of turbulence, even in cool disks.

  16. Cosmic Vorticity and the Origin Halo Spins

    NASA Astrophysics Data System (ADS)

    Libeskind, Noam I.; Hoffman, Yehuda; Steinmetz, Matthias; Gottlöber, Stefan; Knebe, Alexander; Hess, Steffen

    2013-04-01

    In the standard model of cosmology, structure emerges out of a non-rotational flow and the angular momentum of collapsing halos is induced by tidal torques. The growth of angular momentum in the linear and quasi-linear phases is associated with a shear, curl-free, flow and it is well described within the linear framework of tidal torque theory (TTT). However, TTT ceases to be applicable as halos approach turnaround when their ambient flow field becomes rotational. Subsequently, halos become embedded in a vortical flow field and the growth of their angular momentum is affected by the vorticity of their ambient velocity field. Using a cosmological simulation, we have examined the importance of the curl of the velocity field in determining halo spin, finding a significant alignment between the two: the vorticity tends to be perpendicular to the axis of the fastest collapse of the velocity shear tensor (e 1). This is independent of halo masses and cosmic web environment. Our results agree with previous findings on the tendency of halo spin to be perpendicular to e 1, and of the spin of (simulated) halos and (observed) galaxies to be aligned with the large-scale structure. It follows that angular momentum growth proceeds in two distinct phases. First, the angular momentum emerges out of a shear, curl-free, potential flow, as described by TTT. In the second phase, in which halos approach virialization, the angular momentum emerges out of a vortical flow and halo spin becomes partially aligned with the vorticity of the ambient flow field.

  17. Isometric and isokinetic hip strength and agonist/antagonist ratios in symptomatic femoroacetabular impingement.

    PubMed

    Diamond, Laura E; Wrigley, Tim V; Hinman, Rana S; Hodges, Paul W; O'Donnell, John; Takla, Amir; Bennell, Kim L

    2016-09-01

    This study investigated isometric and isokinetic hip strength in individuals with and without symptomatic femoroacetabular impingement (FAI). The specific aims were to: (i) determine whether differences exist in isometric and isokinetic hip strength measures between groups; (ii) compare hip strength agonist/antagonist ratios between groups; and (iii) examine relationships between hip strength and self-reported measures of either hip pain or function in those with FAI. Cross-sectional. Fifteen individuals (11 males; 25±5 years) with symptomatic FAI (clinical examination and imaging (alpha angle >55° (cam FAI), and lateral centre edge angle >39° and/or positive crossover sign (combined FAI))) and 14 age- and sex-matched disease-free controls (no morphological FAI on magnetic resonance imaging) underwent strength testing. Maximal voluntary isometric contraction strength of hip muscle groups and isokinetic hip internal (IR) and external rotation (ER) strength (20°/s) were measured. Groups were compared with independent t-tests and Mann-Whitney U tests. Participants with FAI had 20% lower isometric abduction strength than controls (p=0.04). There were no significant differences in isometric strength for other muscle groups or peak isokinetic ER or IR strength. The ratio of isometric, but not isokinetic, ER/IR strength was significantly higher in the FAI group (p=0.01). There were no differences in ratios for other muscle groups. Angle of peak IR torque was the only feature correlated with symptoms. Individuals with symptomatic FAI demonstrate isometric hip abductor muscle weakness and strength imbalance in the hip rotators. Strength measurement, including agonist/antagonist ratios, may be relevant for clinical management of FAI. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer.

    PubMed

    Roth, Ralf; Donath, Lars; Kurz, Eduard; Zahner, Lukas; Faude, Oliver

    2017-03-01

    The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000). Test-retest-protocol on five separate days. Fifteen healthy sport students (8 female and 7 male) aged 21 to 26. PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks. For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85-0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65). Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    PubMed

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2018-05-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  20. Association of Muscle Endurance, Fatigability, and Strength With Functional Limitation and Mortality in the Health Aging and Body Composition Study

    PubMed Central

    Patel, Kushang V.; Fried, Linda F.; Robinson-Cohen, Cassianne; de Boer, Ian H.; Harris, Tamara; Murphy, Rachel A.; Satterfield, Suzanne; Goodpaster, Bret H.; Shlipak, Michael; Newman, Anne B.; Kestenbaum, Bryan

    2017-01-01

    Background: Mobility limitation is highly prevalent among older adults and is central to the loss of functional independence. Dynamic isokinetic muscle fatigue testing may reveal increased vulnerability to disability and mortality beyond strength testing. Methods: We studied community-dwelling older adults enrolled in the Health Aging and Body Composition study (age range: 71–82) free of mobility disability and who underwent isokinetic muscle fatigue testing in 1999–2000 (n = 1,963). Isokinetic quadriceps work and fatigue index was determined over 30 repetitions and compared with isometric quadriceps maximum torque. Work was normalized to leg lean mass accounting for gender-specific differences (specific work). The primary outcome was incident persistent severe lower extremity limitation (PSLL), defined as two consecutive reports of either having a lot of difficulty or being unable to walk 1/4 mile or climb 10 steps without resting. The secondary outcome was all-cause mortality. Results: There were 608 (31%) occurrences of incident PSLL and 488 (25%) deaths during median follow-up of 9.3 years. After adjustment, lower isokinetic work was associated with significantly greater risks of PSLL and mortality across the full measured range. Hazard ratios per standard deviation lower specific isokinetic work were 1.22 (95% CI 1.12, 1.33) for PSLL and 1.21 (95% CI 1.13, 1.30) for mortality, respectively. Lower isometric strength was associated with PSLL, but not mortality. Fatigue index was not associated with PSLL or mortality. Conclusions: Muscle endurance, estimated by isokinetic work, is an indicator of muscle health associated with mobility limitation and mortality providing important insight beyond strength testing. PMID:27907890

  1. A new device to study isoload eccentric exercise.

    PubMed

    Guilhem, Gaël; Cornu, Christophe; Nordez, Antoine; Guével, Arnaud

    2010-12-01

    This study was designed to develop a new device allowing mechanical analysis of eccentric exercise against a constant load, with a view in mind to compare isoload (IL) and isokinetic (IK) eccentric exercises. A plate-loaded resistance training device was integrated to an IK dynamometer, to perform the acquisition of mechanical parameters (i.e., external torque, angular velocity). To determine the muscular torque produced by the subject, load torque was experimentally measured (TLexp) at 11 different loads from 30° to 90° angle (0° = lever arm in horizontal position). TLexp was modeled to take friction effect and torque variations into account. Validity of modeled load torque (TLmod) was tested by determining the root mean square (RMS) error, bias, and 2SD between the descending part of TLexp (from 30° to 90°) and TLmod. Validity of TLexp was tested by a linear regression and a Passing-Bablok regression. A pilot analysis on 10 subjects was performed to determine the contribution of the torque because of the moment of inertia to the amount of external work (W). Results showed the validity of TLmod (bias = 0%; RMS error = 0.51%) and TLexp SEM = 4.1 N·m; Intraclass correlation coefficient (ICC) = 1.00; slope = 0.99; y-intercept = -0.13). External work calculation showed a satisfactory reproducibility (SEM = 38.3 J; ICC = 0.98) and moment of inertia contribution to W showed a low value (3.2 ± 2.0%). Results allow us to validate the new device developed in this study. Such a device could be used in future work to study IL eccentric exercise and to compare the effect of IL and IK eccentric exercises in standardized conditions.

  2. Linear and angular retroreflecting interferometric alignment target

    DOEpatents

    Maxey, L. Curtis

    2001-01-01

    The present invention provides a method and apparatus for measuring both the linear displacement and angular displacement of an object using a linear interferometer system and an optical target comprising a lens, a reflective surface and a retroreflector. The lens, reflecting surface and retroreflector are specifically aligned and fixed in optical connection with one another, creating a single optical target which moves as a unit that provides multi-axis displacement information for the object with which it is associated. This displacement information is useful in many applications including machine tool control systems and laser tracker systems, among others.

  3. Beta-alanine supplementation improves isometric, but not isotonic or isokinetic strength endurance in recreationally strength-trained young men.

    PubMed

    Bassinello, Diogo; de Salles Painelli, Vitor; Dolan, Eimear; Lixandrão, Manoel; Cajueiro, Monique; de Capitani, Mariana; Saunders, Bryan; Sale, Craig; Artioli, Guilherme G; Gualano, Bruno; Roschel, Hamilton

    2018-06-15

    β-Alanine (BA) supplementation may be ergogenic during high-intensity exercise, primarily due to the buffering of hydrogen cations, although the effects of beta-alanine supplementation on strength endurance are equivocal. The aim of the study was to determine the effects of 4 weeks of beta-alanine supplementation on skeletal muscle endurance using a battery of performance tests. This study employed a parallel group, repeated measures, randomised, double-blinded and placebo-controlled design. Twenty recreationally strength-trained healthy males completed tests of isotonic strength endurance (repeated bench and leg press), along with tests of isometric and isokinetic endurance conducted using an isokinetic dynamometer. Tests were performed before and after a 4 week intervention, comprising an intake of 6.4 g day -1 of BA (n = 9) or placebo (maltodextrin, n = 11). Time-to-exhaustion during the isometric endurance test improved by ~ 17% in the BA group (p < 0.01), while PL remained unchanged. No significant within-group differences (p > 0.1) were shown for any of the performance variables in the isokinetic test (peak torque, fatigue index, total work) nor for the total number of repetitions performed in the isotonic endurance tests (leg or bench press). Four weeks of BA supplementation (6.4 g day -1 ) improved isometric, but not isokinetic or isotonic endurance performance.

  4. Relationships between eccentric hip isokinetic torque and functional performance.

    PubMed

    Baldon, Rodrigo de Marche; Lobato D, Ferreira Moreira; Carvalho, Lívia Pinheiro; Wun P, Yan Lam; Presotti, Cátia Valéria; Serrão, Fábio Viadanna

    2012-02-01

    Recently, attention in sports has been given to eccentric hip-muscle function, both in preventing musculoskeletal injuries and improving performance. To determine the key isokinetic variables of eccentric hip torque that predict the functional performance of women in the single-leg triple long jump (TLJ) and the timed 6-m single-leg hop (TH). Within-subject correlational study. Musculoskeletal laboratory. 32 healthy women age 18-25 y. The participants performed 2 sets of 5 eccentric hip-abductor/adductor and lateral/medial-rotator isokinetic contractions (30°/s) and 3 attempts in the TLJ and TH. The independent variables were the eccentric hip-abductor and -adductor and medial- and lateral-rotator isokinetic peak torque, normalized according to body mass (Nm/kg). The dependent variables were the longest distance achieved in the TLJ normalized according to body height and the shortest time spent during the execution of the TH. The forward-stepwise-regression analysis showed that the combination of the eccentric hip lateral-rotator and -abductor isokinetic peak torque provided the most efficient estimate of both functional tests, explaining 65% of the TLJ variance (P < .001) and 55% of the TH variance (P < .001). Higher values for eccentric hip lateral-rotator and hip-abductor torques reflected better performance. Thus, the eccentric action of these muscles should be considered in the development of physical training programs that aim to increase functional performance.

  5. Comparison of sequence of trunk and arm motions between short and long official distance groups in javelin throwing.

    PubMed

    Liu, Hui; Leigh, Steve; Yu, Bing

    2014-03-01

    The purpose of this study was to determine the effects of sequences of the trunk and arm angular motions on the performance of javelin throwing. In this study, 32 male and 30 female elite javelin throwers participated and were separated into a short official distance group or a long official distance group in each gender. Three-dimensional coordinates of 21 body landmarks and 3 marks on the javelin in the best trial were collected for each subject. Joint center linear velocities and selected trunk and arm segment and joint angles and angular velocities were calculated. The times of the initiations of the selected segment and joint angular motions and maximum angular velocities were determined. The sequences of the initiations of the selected segment and joint angular motions and maximum angular velocities were compared between short and long official distance groups and between genders. The results demonstrated that short and long official distance groups employed similar sequences of the trunk and arm motions. Male and female javelin throwers employed different sequences of the trunk and arm motions. The sequences of the trunk and arm motions were different from those of the maximal joint center linear velocities.

  6. Sprint Acceleration Mechanics: The Major Role of Hamstrings in Horizontal Force Production

    PubMed Central

    Morin, Jean-Benoît; Gimenez, Philippe; Edouard, Pascal; Arnal, Pierrick; Jiménez-Reyes, Pedro; Samozino, Pierre; Brughelli, Matt; Mendiguchia, Jurdan

    2015-01-01

    Recent literature supports the importance of horizontal ground reaction force (GRF) production for sprint acceleration performance. Modeling and clinical studies have shown that the hip extensors are very likely contributors to sprint acceleration performance. We experimentally tested the role of the hip extensors in horizontal GRF production during short, maximal, treadmill sprint accelerations. Torque capabilities of the knee and hip extensors and flexors were assessed using an isokinetic dynamometer in 14 males familiar with sprint running. Then, during 6-s sprints on an instrumented motorized treadmill, horizontal and vertical GRF were synchronized with electromyographic (EMG) activity of the vastus lateralis, rectus femoris, biceps femoris, and gluteus maximus averaged over the first half of support, entire support, entire swing and end-of-swing phases. No significant correlations were found between isokinetic or EMG variables and horizontal GRF. Multiple linear regression analysis showed a significant relationship (P = 0.024) between horizontal GRF and the combination of biceps femoris EMG activity during the end of the swing and the knee flexors eccentric peak torque. In conclusion, subjects who produced the greatest amount of horizontal force were both able to highly activate their hamstring muscles just before ground contact and present high eccentric hamstring peak torque capability. PMID:26733889

  7. Interferometric measurement of angular motion.

    PubMed

    Peña Arellano, Fabián Erasmo; Panjwani, Hasnain; Carbone, Ludovico; Speake, Clive C

    2013-04-01

    This paper describes the design and realization of a homodyne polarization interferometer for measuring angular motion. The optical layout incorporates carefully designed cat's eye retroreflectors that maximize the measurable range of angular motion and facilitate initial alignment. The retroreflectors are optimized and numerically characterized in terms of defocus and spherical aberrations using Zemax software for optical design. The linearity of the measurement is then calculated in terms of the aberrations. The actual physical interferometer is realized as a compact device with optical components from stock and without relying on adjustable holders. Evaluation of its performance using a commercial autocollimator confirmed a reproducibility within 0.1%, a non-linearity of less than 1 ppm with respect to the autocollimator, an upper limit to its sensitivity of about 5 × 10(-11) rad/Hz from audioband down to 100 mHz and an angular measurement range of more than ±1°.

  8. Interferometric measurement of angular motion

    NASA Astrophysics Data System (ADS)

    Peña Arellano, Fabián Erasmo; Panjwani, Hasnain; Carbone, Ludovico; Speake, Clive C.

    2013-04-01

    This paper describes the design and realization of a homodyne polarization interferometer for measuring angular motion. The optical layout incorporates carefully designed cat's eye retroreflectors that maximize the measurable range of angular motion and facilitate initial alignment. The retroreflectors are optimized and numerically characterized in terms of defocus and spherical aberrations using Zemax software for optical design. The linearity of the measurement is then calculated in terms of the aberrations. The actual physical interferometer is realized as a compact device with optical components from stock and without relying on adjustable holders. Evaluation of its performance using a commercial autocollimator confirmed a reproducibility within 0.1%, a non-linearity of less than 1 ppm with respect to the autocollimator, an upper limit to its sensitivity of about 5 × 10-11 rad/sqrt{textrm {Hz}} from audioband down to 100 mHz and an angular measurement range of more than ±1°.

  9. Pseudo-Linear Attitude Determination of Spinning Spacecraft

    NASA Technical Reports Server (NTRS)

    Bar-Itzhack, Itzhack Y.; Harman, Richard R.

    2004-01-01

    This paper presents the overall mathematical model and results from pseudo linear recursive estimators of attitude and rate for a spinning spacecraft. The measurements considered are vector measurements obtained by sun-sensors, fixed head star trackers, horizon sensors, and three axis magnetometers. Two filters are proposed for estimating the attitude as well as the angular rate vector. One filter, called the q-Filter, yields the attitude estimate as a quaternion estimate, and the other filter, called the D-Filter, yields the estimated direction cosine matrix. Because the spacecraft is gyro-less, Euler s equation of angular motion of rigid bodies is used to enable the estimation of the angular velocity. A simpler Markov model is suggested as a replacement for Euler's equation in the case where the vector measurements are obtained at high rates relative to the spacecraft angular rate. The performance of the two filters is examined using simulated data.

  10. Off-Axis and Angular Impulse Measurements on a Lightcraft Engine

    NASA Astrophysics Data System (ADS)

    Libeau, Michael; Myrabo, Leik

    2005-04-01

    A laser pulse into a Lightcraft engine applies three linear impulses and three angular impulses to the vehicle that depend on the engine's position and orientation with respect to the laser beam. The magnitudes on this impulsive reaction determine the vehicle's autonomous beam-riding characteristics. The impulsive reaction applied to the laser Lightcraft is examined and a device capable of measuring the reaction is designed and tested. Previous work has examined only the linear impulse acting in the thrust direction but the new apparatus, termed the Angular Impulse Measuring Device (AIMD), experimentally measures the dominant side impulse and dominant pitching angular impulse generated by the engine after a laser-strike. Recent tests of an 11/10 scale Model 200 Lightcraft were conducted using a 10KW Army laser at White Sands Missile Range. The resulting measurements are presented as a function of laser beam position.

  11. Superconducting six-axis accelerometer

    NASA Technical Reports Server (NTRS)

    Paik, H. J.

    1990-01-01

    A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

  12. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  13. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  14. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  15. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  16. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  17. Task Space Angular Velocity Blending for Real-Time Trajectory Generation

    NASA Technical Reports Server (NTRS)

    Volpe, Richard A. (Inventor)

    1997-01-01

    The invention is embodied in a method of controlling a robot manipulator moving toward a target frame F(sub 0) with a target velocity v(sub 0) including a linear target velocity v and an angular target velocity omega(sub 0) to smoothly and continuously divert the robot manipulator to a subsequent frame F(sub 1) by determining a global transition velocity v(sub 1), the global transition velocity including a linear transition velocity v(sub 1) and an angular transition velocity omega(sub 1), defining a blend time interval 2(tau)(sub 0) within which the global velocity of the robot manipulator is to be changed from a global target velocity v(sub 0) to the global transition velocity v(sub 1) and dividing the blend time interval 2(tau)(sub 0) into discrete time segments (delta)t. During each one of the discrete time segments delta t of the blend interval 2(tau)(sub 0), a blended global velocity v of the manipulator is computed as a blend of the global target velocity v(sub 0) and the global transition velocity v(sub 1), the blended global velocity v including a blended angular velocity omega and a blended linear velocity v, and then, the manipulator is rotated by an incremental rotation corresponding to an integration of the blended angular velocity omega over one discrete time segment (delta)t.

  18. COSMIC VORTICITY AND THE ORIGIN HALO SPINS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libeskind, Noam I.; Steinmetz, Matthias; Gottloeber, Stefan

    2013-04-01

    In the standard model of cosmology, structure emerges out of a non-rotational flow and the angular momentum of collapsing halos is induced by tidal torques. The growth of angular momentum in the linear and quasi-linear phases is associated with a shear, curl-free, flow and it is well described within the linear framework of tidal torque theory (TTT). However, TTT ceases to be applicable as halos approach turnaround when their ambient flow field becomes rotational. Subsequently, halos become embedded in a vortical flow field and the growth of their angular momentum is affected by the vorticity of their ambient velocity field.more » Using a cosmological simulation, we have examined the importance of the curl of the velocity field in determining halo spin, finding a significant alignment between the two: the vorticity tends to be perpendicular to the axis of the fastest collapse of the velocity shear tensor (e{sub 1}). This is independent of halo masses and cosmic web environment. Our results agree with previous findings on the tendency of halo spin to be perpendicular to e{sub 1}, and of the spin of (simulated) halos and (observed) galaxies to be aligned with the large-scale structure. It follows that angular momentum growth proceeds in two distinct phases. First, the angular momentum emerges out of a shear, curl-free, potential flow, as described by TTT. In the second phase, in which halos approach virialization, the angular momentum emerges out of a vortical flow and halo spin becomes partially aligned with the vorticity of the ambient flow field.« less

  19. Optical vibration measurement of mechatronics devices

    NASA Astrophysics Data System (ADS)

    Yanabe, Shigeo

    1993-09-01

    An optical vibration measuring system which enables to detect both linear and angular displacement of 25 nm and 5 prad was developed. The system is mainly composed of a He-Ne laser, a displacement detecting photo-diode and lenses, and has linear and angular displacement magnification mechanism using two different principles of optical lever. The system was applied to measure vibrational characteristics of magnetic head slider of hard disk drives and to measure stator teeth driving velocities of ultrasonic motor.

  20. Measurement of angular velocity in the perception of rotation.

    PubMed

    Barraza, José F; Grzywacz, Norberto M

    2002-09-01

    Humans are sensitive to the parameters of translational motion, namely, direction and speed. At the same time, people have special mechanisms to deal with more complex motions, such as rotations and expansions. One wonders whether people may also be sensitive to the parameters of these complex motions. Here, we report on a series of experiments that explore whether human subjects can use angular velocity to evaluate how fast a rotational motion is. In four experiments, subjects were required to perform a task of speed-of-rotation discrimination by comparing two annuli of different radii in a temporal 2AFC paradigm. Results showed that humans could rely on a sensitive measurement of angular velocity to perform this discrimination task. This was especially true when the quality of the rotational signal was high (given by the number of dots composing the annulus). When the signal quality decreased, a bias towards linear velocity of 5-80% appeared, suggesting the existence of separate mechanisms for angular and linear velocity. This bias was independent from the reference radius. Finally, we asked whether the measurement of angular velocity required a rigid rotation, that is, whether the visual system makes only one global estimate of angular velocity. For this purpose, a random-dot disk was built such that all the dots were rotating with the same tangential speed, irrespectively of radius. Results showed that subjects do not estimate a unique global angular velocity, but that they perceive a non-rigid disk, with angular velocity falling inversely proportionally with radius.

  1. 40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... moisture to aid in setting isokinetic sampling rates prior to a pollutant emission measurement run. The... simultaneously with a pollutant emission measurement run. When it is, calculation of percent isokinetic, pollutant emission rate, etc., for the run shall be based upon the results of the reference method or its...

  2. 40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... moisture to aid in setting isokinetic sampling rates prior to a pollutant emission measurement run. The... simultaneously with a pollutant emission measurement run. When it is, calculation of percent isokinetic, pollutant emission rate, etc., for the run shall be based upon the results of the reference method or its...

  3. 40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... isokinetic sampling rates prior to a pollutant emission measurement run. The approximation method described... with a pollutant emission measurement run. When it is, calculation of percent isokinetic, pollutant emission rate, etc., for the run shall be based upon the results of the reference method or its equivalent...

  4. 40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... moisture to aid in setting isokinetic sampling rates prior to a pollutant emission measurement run. The... simultaneously with a pollutant emission measurement run. When it is, calculation of percent isokinetic, pollutant emission rate, etc., for the run shall be based upon the results of the reference method or its...

  5. 40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... moisture to aid in setting isokinetic sampling rates prior to a pollutant emission measurement run. The... simultaneously with a pollutant emission measurement run. When it is, calculation of percent isokinetic, pollutant emission rate, etc., for the run shall be based upon the results of the reference method or its...

  6. A Comparison of Isotonic, Isokinetic, and Plyometric Training Methods for Vertical Jump Improvement.

    ERIC Educational Resources Information Center

    Miller, Christine D.

    This annotated bibliography documents three training methods used to develop vertical jumping ability and power: isotonic, isokinetics, and plyometric training. Research findings on all three forms of training are summarized and compared. A synthesis of conclusions drawn from the annotated writings is presented. The report includes a glossary of…

  7. Artificial neural networks in knee injury risk evaluation among professional football players

    NASA Astrophysics Data System (ADS)

    Martyna, Michałowska; Tomasz, Walczak; Krzysztof, Grabski Jakub; Monika, Grygorowicz

    2018-01-01

    Lower limb injury risk assessment was proposed, based on isokinetic examination that is a part of standard athlete's biomechanical evaluation performed mainly twice a year. Information about non-contact knee injury (or lack of the injury) sustained within twelve months after isokinetic test, confirmed in USG were verified. Three the most common types of football injuries were taken into consideration: anterior cruciate ligament (ACL) rupture, hamstring and quadriceps muscles injuries. 22 parameters, obtained from isokinetic tests were divided into 4 groups and used as input parameters of five feedforward artificial neural networks (ANNs). The 5th group consisted of all considered parameters. The networks were trained with the use of Levenberg-Marquardt backpropagation algorithm to return value close to 1 for the sets of parameters corresponding injury event and close to 0 for parameters with no injury recorded within 6 - 12 months after isokinetic test. Results of this study shows that ANN might be useful tools, which simplify process of simultaneous interpretation of many numerical parameters, but the most important factor that significantly influence the results is database used for ANN training.

  8. The effect of peculiar complex core balance training on isokinetic muscle functions of the knee and lumbus.

    PubMed

    Lee, Myungsun; Han, Gunsoo

    2016-04-01

    [Purpose] This study aimed to investigate the effect of peculiar complex core balance training on the isokinetic muscle function of the knee joint and lumbus to provide fundamental data for establishing a training program that focuses on improving the performance and prevention of injury by developing the core and low extremity muscles. [Subjects and Methods] The participants in this study included a total of ten high school athletes involved in a throwing event for over five years. The subjects were randomly divided into two groups: The experimental group (N=5) and the control group (N=5). The experimental group underwent peculiar complex core balance training. [Results] According to the analysis of covariance, there was a significant effect of peculiar complex core balance training. Therefore, the isokinetic muscle function of the knee joint and lumbus in the experimental group participating in peculiar complex core balance training was significantly increased compared to the control group. [Conclusion] It is concluded that peculiar complex core balance training had a positive effect on the isokinetic muscle function of the knee and lumbus in throwing event athletes.

  9. [Chronic chondromalacia of the patella: comparison of morphological (magnetic resonance) and functional findings (isokinetic parameters) after rehabilitation].

    PubMed

    Felicetti, G; Avanza, F; Fiori, M; Brignoli, E; Rovescala, R

    1996-01-01

    The knee is a common site for injuries of the cartilage, capsule and ligament, which calls for the use of noninvasive techniques to assess injury severity properly and to plan adequate rehabilitation. Our study was aimed at comparing MR with isokinetic findings. To this purpose, 40 patients were examined; they were all affected with chondromalacia patellae, grades I-III, previously diagnosed at arthroscopy. Namely, 8 patients had grade I and 32 grades II and III chondromalacia. After MR and isokinetic exams, all patients were submitted to a standardized rehabilitation program. Our results indicate a marked decrease in quadriceps strength, especially in the most severe cases; in less severe cases, recovery was complete at 6 months, while the deficit remained in grades II and III injuries. MR yield was not relevant in 4 of 8 cases, while isokinetic findings were negative in one case. Both methods were positive in the most severe cases. At 6 months, both functional and MR findings were normal in grade I injuries, while some alterations remained in the others.

  10. Results and Conclusions from the NASA Isokinetic Total Water Content Probe 2009 IRT Test

    NASA Technical Reports Server (NTRS)

    Reehorst, Andrew; Brinker, David

    2010-01-01

    The NASA Glenn Research Center has developed and tested a Total Water Content Isokinetic Sampling Probe. Since, by its nature, it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument comprises the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Results and conclusions are presented from probe tests in the NASA Glenn Icing Research Tunnel (IRT) during January and February 2009. The use of reference probe heat and the control of air pressure in the water vapor measurement subsystem are discussed. Several run-time error sources were found to produce identifiable signatures that are presented and discussed. Some of the differences between measured Isokinetic Total Water Content Probe and IRT calibration seems to be caused by tunnel humidification and moisture/ice crystal blow around. Droplet size, airspeed, and liquid water content effects also appear to be present in the IRT calibration. Based upon test results, the authors provide recommendations for future Isokinetic Total Water Content Probe development.

  11. Linear momentum, angular momentum and energy in the linear collision between two balls

    NASA Astrophysics Data System (ADS)

    Hanisch, C.; Hofmann, F.; Ziese, M.

    2018-01-01

    In an experiment of the basic physics laboratory, kinematical motion processes were analysed. The motion was recorded with a standard video camera having frame rates from 30 to 240 fps the videos were processed using video analysis software. Video detection was used to analyse the symmetric one-dimensional collision between two balls. Conservation of linear and angular momentum lead to a crossover from rolling to sliding directly after the collision. By variation of the rolling radius the system could be tuned from a regime in which the balls move away from each other after the collision to a situation in which they re-collide.

  12. Identification of cardiac repercussions after intense and prolonged concentric isokinetic exercise in young sedentary people.

    PubMed

    Le Goff, Caroline; Kaux, Jean-François; Couffignal, Vincent; Coubard, Romain; Mélon, Pierre; Cavalier, Etienne; Croisier, Jean-Louis

    2015-09-01

    Cardiopathies are the world's leading cause of mortality and morbidity. Although rare, cardiovascular accidents can occur during intense and infrequent sporting activity, particularly among those who are unaware of their heart condition. The development of cardiospecific biochemical markers has led to a reconsideration of the role of biology in the diagnosis of cardiovascular illnesses. The aim of this study therefore was, through the use of cardiac biomarker assays, to highlight the impact of sustained physical effort in the form of intense and prolonged concentric isokinetic exercise and to research potential cardiovascular risks. Eighteen subjects participated in a maximal concentric isokinetic exercise involving 30 knee flexion-extensions for each leg. Five blood tests were taken to study the kinetics of the cardiac biomarkers. Haemodynamic parameters were measured continuously using a Portapres, and respiratory parameters were measured using a Sensormedics Vmax 29C. The results showed significant increases in the creatine kinase, myoglobin, homocysteine and haemoglobin cardiac markers. Evolutionary trends were also observed for the following biomarkers: NT-proBNP, myeloperoxydase and C-reactive protein. All the physiological parameters measured presented statistically significant changes. Isokinetic effort leads to the release of cardiac markers in the blood, but these do not exceed the reference values in healthy subjects. Maximal concentric isokinetic exercise does not, therefore, lead to an increased risk of cardiovascular pathologies. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  13. Lower-extremity isokinetic strength profiling in professional rugby league and rugby union.

    PubMed

    Brown, Scott R; Brughelli, Matt; Griffiths, Peter C; Cronin, John B

    2014-03-01

    While several studies have documented isokinetic knee strength in junior and senior rugby league players, investigations of isokinetic knee and hip strength in professional rugby union players are limited. The purpose of this study was to provide lower-extremity strength profiles and compare isokinetic knee and hip strength of professional rugby league and rugby union players. 32 professional rugby league and 25 professional rugby union players. Cross-sectional analysis. Isokinetic dynamometry was used to evaluate peak torque and strength ratios of the dominant and nondominant legs during seated knee-extension/ flexion and supine hip-extension/flexion actions at 60°/s. Forwards from both codes were taller and heavier and had a higher body-mass index than the backs of each code. Rugby union forwards produced significantly (P < .05) greater peak torque during knee flexion in the dominant and nondominant legs (ES = 1.81 and 2.02) compared with rugby league forwards. Rugby league backs produced significantly greater hip-extension peak torque in the dominant and nondominant legs (ES = 0.83 and 0.77) compared with rugby union backs. There were no significant differences in hamstring-to-quadriceps ratios between code, position, or leg. Rugby union forwards and backs produced significantly greater knee-flexion-to-hip-extension ratios in the dominant and nondominant legs (ES = 1.49-2.26) than rugby union players. It seems that the joint torque profiles of players from rugby league and union codes differ, which may be attributed to the different demands of each code.

  14. Comparing passive angle-torque curves recorded simultaneously with a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments.

    PubMed

    Buckner, Samuel L; Jenkins, Nathaniel D M; Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Cramer, Joel T

    2015-05-01

    The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) completed stretch tolerance assessments on a custom-built apparatus where passive torque was measured simultaneously from an isokinetic dynamometer and a load cell. Passive torque values that corresponded with the last 10° of dorsiflexion, verified by surface electromyographic amplitude, were analyzed for each device (θ1, θ2, θ3, …, θ10). Passive torque values measured with the load cell were greater (p ≤ 0.05) than the dynamometer torque values for θ4 through θ10. There were more statistical differentiations among joint angles for passive torque measured by the load cell, and the load cell measured a greater (p ≤ 0.01) increase in passive torque and PS than the isokinetic dynamometer. These findings suggested that when examining the angle-torque curves from passive dorsiflexion stretch tolerance tests, a load cell placed under the distal end of the foot may be more sensitive than the torque recorded from an isokinetic dynamometer. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Projection of angular momentum via linear algebra

    DOE PAGES

    Johnson, Calvin W.; O'Mara, Kevin D.

    2017-12-01

    Projection of many-body states with good angular momentum from an initial state is usually accomplished by a three-dimensional integral. Here, we show how projection can instead be done by solving a straightforward system of linear equations. We demonstrate the method and give sample applications tomore » $$^{48}$$Cr and $$^{60}$$Fe in the $pf$ shell. This new projection scheme, which is competitive against the standard numerical quadrature, should also be applicable to other quantum numbers such as isospin and particle number.« less

  16. Projection of angular momentum via linear algebra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Calvin W.; O'Mara, Kevin D.

    Projection of many-body states with good angular momentum from an initial state is usually accomplished by a three-dimensional integral. Here, we show how projection can instead be done by solving a straightforward system of linear equations. We demonstrate the method and give sample applications tomore » $$^{48}$$Cr and $$^{60}$$Fe in the $pf$ shell. This new projection scheme, which is competitive against the standard numerical quadrature, should also be applicable to other quantum numbers such as isospin and particle number.« less

  17. Projection of angular momentum via linear algebra

    NASA Astrophysics Data System (ADS)

    Johnson, Calvin W.; O'Mara, Kevin D.

    2017-12-01

    Projection of many-body states with good angular momentum from an initial state is usually accomplished by a three-dimensional integral. We show how projection can instead be done by solving a straightforward system of linear equations. We demonstrate the method and give sample applications to 48Cr and 60Fe in the p f shell. This new projection scheme, which is competitive against the standard numerical quadrature, should also be applicable to other quantum numbers such as isospin and particle number.

  18. RELATIONSHIP BETWEEN ISOKINETIC KNEE STRENGTH AND JUMP CHARACTERISTICS FOLLOWING ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

    PubMed

    Laudner, Kevin; Evans, Daniel; Wong, Regan; Allen, Aaron; Kirsch, Tom; Long, Brian; Meister, Keith

    2015-06-01

    Clinicians are often challenged when making return-to-play decisions following anterior cruciate ligament reconstruction (ACL-R). Isokinetic strength and jump performance testing are common tools used to make this decision. Unfortunately, vertical jump performance standards have not been clearly established and many clinicians do not have access to isokinetic testing equipment. To establish normative jump and strength characteristics in ACL-R patients cleared by an orthopedic physician to return-to-play and to determine if relationships exist between knee isokinetic strength measurements and jump characteristics described using an electronic jump map system. Descriptive laboratory study. Thirty-three ACL-R patients who had been cleared to return to athletic competition participated in this study. Twenty-six of these ACL-R participants were also matched to 26 asymptomatic athletes based on sex, limb, height, and mass to determine isokinetic strength and jump characteristic differences between groups. Jump tests consisted of single leg vertical, double leg vertical, and a 4-jump single leg vertical jump assessed using an electronic jump mat system. Independent t-tests were used to determine differences between groups and multiple regression analyses were used to identify any relationships between jump performance and knee strength (p<0.05). The ACL-R group had lower vertical jump capabilities and some bilateral knee strength deficiencies compared to the matched control group. The ACL-R group also showed several moderate-to-strong positive relationships for both knee extension and flexion strength with several jump performance characteristics, such as single and double leg vertical jump height. The current results indicate that ACL-R patients present with several knee strength and vertical jump differences compared to a matched control group at the time of return-to-play. Also, ACL-R patient's performance on an electronic jump mat system is strongly related to isokinetic knee strength measures. 2b.

  19. Skeletal muscle power and fatigue at the tolerable limit of ramp-incremental exercise in COPD.

    PubMed

    Cannon, Daniel T; Coelho, Ana Claudia; Cao, Robert; Cheng, Andrew; Porszasz, Janos; Casaburi, Richard; Rossiter, Harry B

    2016-12-01

    Muscle fatigue (a reduced power for a given activation) is common following exercise in chronic obstructive pulmonary disease (COPD). Whether muscle fatigue, and reduced maximal voluntary locomotor power, are sufficient to limit whole body exercise in COPD is unknown. We hypothesized in COPD: 1) exercise is terminated with a locomotor muscle power reserve; 2) reduction in maximal locomotor power is related to ventilatory limitation; and 3) muscle fatigue at intolerance is less than age-matched controls. We used a rapid switch from hyperbolic to isokinetic cycling to measure the decline in peak isokinetic power at the limit of incremental exercise ("performance fatigue") in 13 COPD patients (FEV 1 49 ± 17%pred) and 12 controls. By establishing the baseline relationship between muscle activity and isokinetic power, we apportioned performance fatigue into the reduction in muscle activation and muscle fatigue. Peak isokinetic power at intolerance was ~130% of peak incremental power in controls (274 ± 73 vs. 212 ± 84 W, P < 0.05), but ~260% in COPD patients (187 ± 141 vs. 72 ± 34 W, P < 0.05), greater than controls (P < 0.05). Muscle fatigue as a fraction of baseline peak isokinetic power was not different in COPD patients vs. controls (0.11 ± 0.20 vs. 0.19 ± 0.11). Baseline to intolerance, the median frequency of maximal isokinetic muscle activity, was unchanged in COPD patients but reduced in controls (+4.3 ± 11.6 vs. -5.5 ± 7.6%, P < 0.05). Performance fatigue as a fraction of peak incremental power was greater in COPD vs. controls and related to resting (FEV 1 /FVC) and peak exercise (V̇ E /maximal voluntary ventilation) pulmonary function (r 2 = 0.47 and 0.55, P < 0.05). COPD patients are more fatigable than controls, but this fatigue is insufficient to constrain locomotor power and define exercise intolerance. Copyright © 2016 the American Physiological Society.

  20. Running from Paris to Beijing: biomechanical and physiological consequences.

    PubMed

    Millet, Guillaume Y; Morin, Jean-Benoît; Degache, Francis; Edouard, Pascal; Feasson, Léonard; Verney, Julien; Oullion, Roger

    2009-12-01

    The purpose of this study was to examine the physiological and biomechanical changes occurring in a subject after running 8,500 km in 161 days (i.e. 52.8 km daily). Three weeks before, 3 weeks after (POST) and 5 months after (POST+5) running from Paris to Beijing, energy cost of running (Cr), knee flexor and extensor isokinetic strength and biomechanical parameters (using a treadmill dynamometer) at different velocities were assessed in an experienced ultra-runner. At POST, there was a tendency toward a 'smoother' running pattern, as shown by (a) a higher stride frequency and duty factor, and a reduced aerial time without a change in contact time, (b) a lower maximal vertical force and loading rate at impact and (c) a decrease in both potential and kinetic energy changes at each step. This was associated with a detrimental effect on Cr (+6.2%) and a loss of strength at all angular velocities for both knee flexors and extensors. At POST+5, the subject returned to his original running patterns at low but not at high speeds and maximal strength remained reduced at low angular velocities (i.e. at high levels of force). It is suggested that the running pattern changes observed in the present study were a strategy adopted by the subject to reduce the deleterious effects of long distance running. However, the running pattern changes could partly be linked to the decrease in maximal strength.

  1. [Quantitative measurement of axial rigidity, functional status and health-related quality of life in patients with Parkinson's disease].

    PubMed

    Cano de la Cuerda, Roberto; Vela, Lydia; Miangolarra-Page, Juan Carlos; Macías-Macías, Yolanda; Muñoz-Hellín, Elena

    2010-08-16

    Rigidity is a cardinal symptom of Parkinson's disease (PD). Clinically, rigidity is usually assessed by passively flexing and extending a patient's limb. Few studies have assessed rigidity in trunk muscles in PD patients. To develop an objective measurement to quantify trunk rigidity in PD patients, and to examine its relationship with disease severity using the Hoehn and Yahr staging score (HY) and the Unified Parkinson's Disease Rating Scale III (UPDRS-III), disease duration, functional status with the Schwab & England activities of daily living scale and health related quality of life (HRQoL) was assessed with the European Quality of Life-5 Dimensions and Parkinson's Disease Questionnaire-39 items (PDQ-39). An isokinetic dynamometer Biodex System 3 was employed to assess trunk rigidity in 36 PD patients. Passive trunk flexion and extension at 3 angular velocities, 30 degrees/s, 45 degrees/s and 60 degrees /s were applied and resistive torques were recorded as trunk flexor and extensors rigidity. Significant correlations between trunk flexors-extensors tone and HY staging score, UPDRS-III, disease duration and functional status at 30 degrees/s, 45 degrees/s and 60 degrees/s were obtained. Trunk rigidity was correlated with the HRQoL assessed with the PDQ-39. Our results suggest that the 30 degrees/s, 45 degrees/s and 60 degrees/s angular velocities of this objective method was valid to assess trunk rigidity and was correlated with disease severity, disease duration, functional status and HRQoL in PD patients.

  2. Optical elements with extended depth of focus and arbitrary distribution of intensity along the focal segment obtained by angular modulation of the optical power

    NASA Astrophysics Data System (ADS)

    Kakarenko, K.; Ducin, I.; Jaroszewicz, Z.; Kołodziejczyk, A.; Petelczyc, K.; Stompor, A.; Sypek, M.

    2015-04-01

    Light Sword Lens (LSL), i.e., an optical element with extended depth of focus (EDOF) characterized by angular modulation of the optical power in its conventional form is characterized by a linear relationship between the optical power and the angular coordinate of the corresponding angular lens sector. This dependence may be manipulated in function of the required design needs. In the present communicate this additional degree of freedom of design is used for elimination of the LSL shape discontinuity.

  3. Vestibular functions and sleep in space experiments. [using rhesus and owl monkeys

    NASA Technical Reports Server (NTRS)

    Perachio, A. A.

    1977-01-01

    Physical indices of sleep were continuously monitored in an owl monkey living in a chamber continuously rotating at a constant angular velocity. The electrophysiological data obtained from chronically implanted electrodes was analyzed to determine the chronic effects of vestibular stimulation on sleep and wakefulness cycles. The interaction of linear and angular acceleration on the vestibulo-ocular reflex was investigated in three rhesus monkeys at various angular accelerations.

  4. Optomechanical measurement of photon spin angular momentum and optical torque in integrated photonic devices.

    PubMed

    He, Li; Li, Huan; Li, Mo

    2016-09-01

    Photons carry linear momentum and spin angular momentum when circularly or elliptically polarized. During light-matter interaction, transfer of linear momentum leads to optical forces, whereas transfer of angular momentum induces optical torque. Optical forces including radiation pressure and gradient forces have long been used in optical tweezers and laser cooling. In nanophotonic devices, optical forces can be significantly enhanced, leading to unprecedented optomechanical effects in both classical and quantum regimes. In contrast, to date, the angular momentum of light and the optical torque effect have only been used in optical tweezers but remain unexplored in integrated photonics. We demonstrate the measurement of the spin angular momentum of photons propagating in a birefringent waveguide and the use of optical torque to actuate rotational motion of an optomechanical device. We show that the sign and magnitude of the optical torque are determined by the photon polarization states that are synthesized on the chip. Our study reveals the mechanical effect of photon's polarization degree of freedom and demonstrates its control in integrated photonic devices. Exploiting optical torque and optomechanical interaction with photon angular momentum can lead to torsional cavity optomechanics and optomechanical photon spin-orbit coupling, as well as applications such as optomechanical gyroscopes and torsional magnetometry.

  5. Optomechanical measurement of photon spin angular momentum and optical torque in integrated photonic devices

    PubMed Central

    He, Li; Li, Huan; Li, Mo

    2016-01-01

    Photons carry linear momentum and spin angular momentum when circularly or elliptically polarized. During light-matter interaction, transfer of linear momentum leads to optical forces, whereas transfer of angular momentum induces optical torque. Optical forces including radiation pressure and gradient forces have long been used in optical tweezers and laser cooling. In nanophotonic devices, optical forces can be significantly enhanced, leading to unprecedented optomechanical effects in both classical and quantum regimes. In contrast, to date, the angular momentum of light and the optical torque effect have only been used in optical tweezers but remain unexplored in integrated photonics. We demonstrate the measurement of the spin angular momentum of photons propagating in a birefringent waveguide and the use of optical torque to actuate rotational motion of an optomechanical device. We show that the sign and magnitude of the optical torque are determined by the photon polarization states that are synthesized on the chip. Our study reveals the mechanical effect of photon’s polarization degree of freedom and demonstrates its control in integrated photonic devices. Exploiting optical torque and optomechanical interaction with photon angular momentum can lead to torsional cavity optomechanics and optomechanical photon spin-orbit coupling, as well as applications such as optomechanical gyroscopes and torsional magnetometry. PMID:27626072

  6. Angular behavior of synchrotron radiation harmonics.

    PubMed

    Bagrov, V G; Bulenok, V G; Gitman, D M; Jara, Jose Acosta; Tlyachev, V B; Jarovoi, A T

    2004-04-01

    The detailed analysis of angular dependence of the synchrotron radiation (SR) is presented. Angular distributions of linear and circular polarization integrated over all harmonics, well known for relativistic electron energies, are extended to include radiation from electrons that are not fully relativistic. In particular, we analyze the angular dependence of the integral SR intensity and peculiarities of the angular dependence of the first harmonics SR. Studying spectral SR intensities, we have discovered their unexpected angular behavior, completely different from that of the integral SR intensity; namely, for any given synchrotron frequency, maxima of the spectral SR intensities recede from the orbit plane with increasing particle energy. Thus, in contrast with the integral SR intensity, the spectral ones have the tendency to deconcentrate themselves on the orbit plane.

  7. Optical angular momentum and atoms

    PubMed Central

    2017-01-01

    Any coherent interaction of light and atoms needs to conserve energy, linear momentum and angular momentum. What happens to an atom’s angular momentum if it encounters light that carries orbital angular momentum (OAM)? This is a particularly intriguing question as the angular momentum of atoms is quantized, incorporating the intrinsic spin angular momentum of the individual electrons as well as the OAM associated with their spatial distribution. In addition, a mechanical angular momentum can arise from the rotation of the entire atom, which for very cold atoms is also quantized. Atoms therefore allow us to probe and access the quantum properties of light’s OAM, aiding our fundamental understanding of light–matter interactions, and moreover, allowing us to construct OAM-based applications, including quantum memories, frequency converters for shaped light and OAM-based sensors. This article is part of the themed issue ‘Optical orbital angular momentum’. PMID:28069766

  8. Free (Reactionless) Torque Generation—Or Free Propulsion Concept

    NASA Astrophysics Data System (ADS)

    Djordjev, Bojidar

    2010-01-01

    The basic principle in Newtonian Mechanics is based upon equal and opposite forces. Placing the vectors of velocity, acceleration, force and momentum of interacting objects along a single line satisfies the claim it is a linear or a 1-D concept. Classical Mechanics states that there are two main kinds of motion, linear and angular motion. Similarly placing the vectors of angular velocity, angular acceleration, torque and angular momentum along a line in the case of rotation in fact brings a plane 2-D interaction to the well known 1-D Newtonian concept. This adaptation transforms Classical Mechanics into a 1-D concept as well and presents a conformation that the linear concept is the only possible one. The Laws of Conservation of Momentum and Angular Momentum are results of the 1-D concept. But the world contains 3 geometrical spatial dimensions. Within the 3-D world there can exist 1-D, 2-D and 3-D kinds of interaction. The question is how to believe that the 3-D world can really be composed of a 1-D interaction or interactions made equal to the 1-D concept only? Examine a gyroscope—the only one mechanical device that is capable of performng 3-D behavior. The problem is that a gyroscope cannot perform three permanent and unidirectional torques that are fixed in space acting about perpendicular axes. This impossibility conforms to a 1-D concept. The idea is to find a solution that can be achieved for the 3-D concept.

  9. Anisotropies in the linear polarization of vacancy photoluminescence in diamond induced by crystal rotations and strong magnetic fields

    NASA Astrophysics Data System (ADS)

    Braukmann, D.; Popov, V. P.; Glaser, E. R.; Kennedy, T. A.; Bayer, M.; Debus, J.

    2018-03-01

    We study the linear polarization properties of the photoluminescence of ensembles of neutral and negatively charged nitrogen vacancies and neutral vacancies in diamond crystals as a function of their symmetry and their response to strong external magnetic fields. The linear polarization degree, which exceeds 10% at room temperature, and rotation of the polarization plane of their zero-phonon lines significantly depend on the crystal rotation around specific axes demonstrating anisotropic angular evolutions. The sign of the polarization plane rotation is changed periodically through the crystal rotation, which indicates a switching between electron excited states of orthogonal linear polarizations. At external magnetic fields of up to 10 T, the angular dependencies of the linear polarization degree experience a remarkable phase shift. Moreover, the rotation of the linear polarization plane increases linearly with rising magnetic field at 6 K and room temperature, for the negatively charged nitrogen vacancies, which is attributed to magneto-optical Faraday rotation.

  10. Knee Extensor and Flexor Torque Development with Concentric and Eccentric Isokinetic Training

    ERIC Educational Resources Information Center

    Miller, Larry E.; Pierson, Lee M.; Nickols-Richardson, Sharon M.; Wootten, David F.; Selmon, Serah E.; Ramp, Warren K.; Herbert, William G.

    2006-01-01

    This study assessed muscular torque and rate of torque development following concentric (CON) or eccentric (ECC) isokinetic training. Thirty-eight women were randomly assigned to either CON or ECC training groups. Training consisted of knee extension and flexion of the nondominant leg three times per week for 20 weeks (SD = 1). Eccentric training…

  11. Sex Comparisons for Relative Peak Torque and Electromyographic Mean Frequency during Fatigue

    ERIC Educational Resources Information Center

    Stock, Matt S.; Beck, Travis W.; DeFreitas, Jason M.; Ye, Xin

    2013-01-01

    Purpose: This study compared the relative peak torque and normalized electromyographic (EMG) mean frequency (MNF) responses during fatiguing isokinetic muscle actions for men versus women. Method: Twenty men M[subscript age] ± SD = 22 ± 2 years) and 20 women M[subscript age] ± SD = 22 ± 1 years) performed 50 maximal concentric isokinetic muscle…

  12. Comparison of 3-Dimensional Shoulder Complex Kinematics in Individuals With and Without Shoulder Pain, Part 2: Glenohumeral Joint

    PubMed Central

    LAWRENCE, REBEKAH L.; BRAMAN, JONATHAN P.; STAKER, JUSTIN L.; LAPRADE, ROBERT F.; LUDEWIG, PAULA M.

    2015-01-01

    STUDY DESIGN Cross-sectional. OBJECTIVES To compare differences in glenohumeral joint angular motion and linear translations between symptomatic and asymptomatic individuals during shoulder motion performed in 3 planes of humerothoracic elevation. BACKGROUND Numerous clinical theories have linked abnormal glenohumeral kinematics, including decreased glenohumeral external rotation and increased superior translation, to individuals with shoulder pain and impingement diagnoses. However, relatively few studies have investigated glenohumeral joint angular motion and linear translations in this population. METHODS Transcortical bone pins were inserted into the scapula and humerus of 12 a symptomatic and 10 symptomatic participants for direct bone-fixed tracking using electromagnetic sensors. Glenohumeral joint angular positions and linear translations were calculated during active shoulder flexion, abduction, and scapular plane abduction. RESULTS Differences between groups in angular positions were limited to glenohumeral elevation, coinciding with a reduction in scapulothoracic upward rotation. Symptomatic participants demonstrated 1.4 mm more anterior glenohumeral translation between 90° and 120° of shoulder flexion and an average of 1 mm more inferior glenohumeral translation throughout shoulder abduction. CONCLUSION Differences in glenohumeral kinematics exist between symptomatic and a symptomatic individuals. The clinical implications of these differences are not yet understood, and more research is needed to understand the relationship between abnormal kinematics, shoulder pain, and pathoanatomy. PMID:25103132

  13. Angular-Rate Estimation Using Delayed Quaternion Measurements

    NASA Technical Reports Server (NTRS)

    Azor, R.; Bar-Itzhack, I. Y.; Harman, R. R.

    1999-01-01

    This paper presents algorithms for estimating the angular-rate vector of satellites using quaternion measurements. Two approaches are compared one that uses differentiated quaternion measurements to yield coarse rate measurements, which are then fed into two different estimators. In the other approach the raw quaternion measurements themselves are fed directly into the two estimators. The two estimators rely on the ability to decompose the non-linear part of the rotas rotational dynamics equation of a body into a product of an angular-rate dependent matrix and the angular-rate vector itself. This non unique decomposition, enables the treatment of the nonlinear spacecraft (SC) dynamics model as a linear one and, thus, the application of a PseudoLinear Kalman Filter (PSELIKA). It also enables the application of a special Kalman filter which is based on the use of the solution of the State Dependent Algebraic Riccati Equation (SDARE) in order to compute the gain matrix and thus eliminates the need to compute recursively the filter covariance matrix. The replacement of the rotational dynamics by a simple Markov model is also examined. In this paper special consideration is given to the problem of delayed quaternion measurements. Two solutions to this problem are suggested and tested. Real Rossi X-Ray Timing Explorer (RXTE) data is used to test these algorithms, and results are presented.

  14. Is Linear Displacement Information Or Angular Displacement Information Used During The Adaptation of Pointing Responses To An Optically Shifted Image?

    NASA Technical Reports Server (NTRS)

    Bautista, Abigail B.

    1994-01-01

    Twenty-four observers looked through a pair of 20 diopter wedge prisms and pointed to an image of a target which was displaced vertically from eye level by 6 cm at a distance of 30 cm. Observers pointed 40 times, using only their right hand, and received error-corrective feedback upon termination of each pointing response (terminal visual feedback). At three testing distances, 20, 30, and 40 cm, ten pre-exposure and ten post-exposure pointing responses were recorded for each hand as observers reached to a mirror-viewed target located at eye level. The difference between pre- and post-exposure pointing response (adaptive shift) was compared for both Exposed and Unexposed hands across all three testing distances. The data were assessed according to the results predicted by two alternative models for processing spatial-information: one using angular displacement information and another using linear displacement information. The angular model of spatial mapping best predicted the observer's pointing response for the Exposed hand. Although the angular adaptive shift did not change significantly as a function of distance (F(2,44) = 1.12, n.s.), the linear adaptive shift increased significantly over the three testing distances 02 44) = 4.90 p less than 0.01).

  15. [Inferring landmark displacements from changes in cephalometric angles].

    PubMed

    Xu, T; Baumrind, S

    2001-07-01

    To investigate the appropriateness of using changes in angular measurements to reflect the actually profile changes. The sample consists of 48 growing malocclusion patients, contained 24 Class I and 24 Class II subjects, treated by an experienced orthodontist using Edgewise technique. Landmark and superimpositional data were extracted from the previously prepared numerical database. Three pairs of angular and linear measures were computed by the Craniofacial Software Package. Although the associations between all three angular measures and their corresponding linear measures are statistically significant at the 0.001 level, the disagreement between these three pairs of measures are 10.4%, 22.9% and 37.5% respectively in this sample. The direction of displacement of anterior facial landmarks during growth and treatment cannot reliably be inferred merely from changes in cephalometric Angles.

  16. Effects of the circularly polarized beam of linearized gravitational waves

    NASA Astrophysics Data System (ADS)

    Barker, W.

    2017-08-01

    Solutions of the linearized Einstein equations are found that describe a transversely confined beam of circularly polarized gravitational waves on a Minkowski backdrop. By evaluating the cycle-averaged stress-energy-momentum pseudotensor of Landau & Lifshitz it is found that the angular momentum density is concentrated in the ‘skin’ at the edge of the beam where the intensity falls, and that the ratio of angular momentum to energy per unit length of the beam is 2/ω , where ω is the wave frequency, as expected for a beam of spin-2 gravitons. For sharply-defined, uniform, axisymmetric beams, the induced background metric is shown to produce the gravitomagnetic field and frame-dragging effects of a gravitational solenoid, whilst the angular momentum current helically twists the space at infinite radius along the beam axis.

  17. 2D versus 3D in the kinematic analysis of the horse at the trot.

    PubMed

    Miró, F; Santos, R; Garrido-Castro, J L; Galisteo, A M; Medina-Carnicer, R

    2009-08-01

    The handled trot of three Lusitano Purebred stallions was analyzed by using 2D and 3D kinematical analysis methods. Using the same capture and analysis system, 2D and 3D data of some linear (stride length, maximal height of the hoof trajectories) and angular (angular range of motion, inclination of bone segments) variables were obtained. A paired Student T-test was performed in order to detect statistically significant differences between data resulting from the two methodologies With respect to the angular variables, there were significant differences in scapula inclination, shoulder angle, cannon inclination and protraction-retraction angle in the forelimb variables, but none of them were statistically different in the hind limb. Differences between the two methods were found in most of the linear variables analyzed.

  18. A study of angular spectrum and limited diffraction beams for calculation of field of array transducers

    NASA Astrophysics Data System (ADS)

    Cheng, Jiqi; Lu, Jian-Yu

    2002-05-01

    Angular spectrum is one of the most powerful tools for field calculation. It is based on linear system theory and the Fourier transform and is used for the calculation of propagating sound fields at different distances. In this report, the generalization and interpretation of the angular spectrum and its intrinsic relationship with limited diffraction beams are studied. With an angular spectrum, the field at the surface of a transducer is decomposed into limited diffractions beams. For an array transducer, a linear relationship between the quantized fields at the surface of elements of the array and the propagating field at any point in space can be established. For an annular array, the field is decomposed into limited diffraction Bessel beams [P. D. Fox and S. Holm, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 49, 85-93 (2002)], while for a two-dimensional (2-D) array the field is decomposed into limited diffraction array beams [J-y. Lu and J. Cheng, J. Acoust. Soc. Am. 109, 2397-2398 (2001)]. The angular spectrum reveals the intrinsic link between these decompositions. [Work supported in part by Grant 5RO1 HL60301 from NIH.

  19. The effects of creatine supplementation on thermoregulation and isokinetic muscular performance following acute (3-day) supplementation.

    PubMed

    Rosene, J M; Matthews, T D; Mcbride, K J; Galla, A; Haun, M; Mcdonald, K; Gagne, N; Lea, J; Kasen, J; Farias, C

    2015-12-01

    The purpose of this investigation was to determine the effects of 3 d of creatine supplementation on thermoregulation and isokinetic muscular performance. Fourteen males performed two exercise bouts following 3 d of creatine supplementation and placebo. Subjects exercised for 60 min at 60-65% of VO2max in the heat followed by isokinetic muscular performance at 60, 180, and 300°·s(-1). Dependent variables for pre- and postexercise included nude body weight, urine specific gravity, and serum creatinine levels. Total body water, extracellular water and intracellular water were measured pre-exercise. Core temperature was assessed every 5 min during exercise. Peak torque and Fatigue Index were used to assess isokinetic muscular performance. Core temperature increased during the run for both conditions. Total body water and extracellular water were significantly greater (P<0.05) following creatine supplementation. No significant difference (P>0.05) was found between conditions for intracellular water, nude body weight, urine specific gravity, and serum creatinine. Pre-exercise scores for urine specific gravity and serum creatinine were significantly less (P<0.05) versus post-exercise. No significant differences (P>0.05) were found in peak torque values or Fatigue Index between conditions for each velocity. A significant (P<0.05) overall velocity effect was found for both flexion and extension. As velocity increased, mean peak torque values decreased. Three d of creatine supplementation does not affect thermoregulation during submaximal exercise in the heat and is not enough to elicit an ergogenic effect for isokinetic muscle performance following endurance activity.

  20. Knee-joint proprioception during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training

    NASA Technical Reports Server (NTRS)

    Bernauer, E. M.; Walby, W. F.; Ertl, A. C.; Dempster, P. T.; Bond, M.; Greenleaf, J. E.

    1994-01-01

    To determine if daily isotonic exercise or isokinetic exercise training coupled with daily leg proprioceptive training, would influence leg proprioceptive tracking responses during bed rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a no-exercise (NOE) training control group (n = 5), and isotonic exercise (ITE, n = 7) and isokinetic exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min periods.d-1, 5 d.week-1. Only the IKE group performed proprioceptive training using a new isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pre-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p < 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9* +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.5%, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both isotonic exercise training (without additional proprioceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

  1. Knee-joint proprioception during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training.

    PubMed

    Bernauer, E M; Walby, W F; Ertl, A C; Dempster, P T; Bond, M; Greenleaf, J E

    1994-12-01

    To determine if daily isotonic exercise or isokinetic exercise training coupled with daily leg proprioceptive training, would influence leg proprioceptive tracking responses during bed rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a no-exercise (NOE) training control group (n = 5), and isotonic exercise (ITE, n = 7) and isokinetic exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min periods.d-1, 5 d.week-1. Only the IKE group performed proprioceptive training using a new isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pre-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p < 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9* +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.5%, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both isotonic exercise training (without additional proprioceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

  2. Knee-Joint Proprioception During 30-Day 6 deg Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

    NASA Technical Reports Server (NTRS)

    Bernauer, E. M.; Walby, W. F.; Ertl, A. C.; Dempster, P. T.; Bond, M.; Greenleaf, J. E.

    1994-01-01

    To determine if daily isotonic exercise or isokinetic exercise training coupled with daily log proprioceptive training, would influence log proprioceptive tracking responses during Bed Rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a NO-Exercise (NOE) training control group (n = 5), and IsoTanic Exercise (ITE, n = 7) and IsoKinetic Exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min period / d, 5 d /week. Only the IKE group performed proprioceptive training using a now isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pro-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p less than 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9 +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.50, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both lsotonic exercise training (without additional propriaceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

  3. Adaptation to vestibular disorientation. XI, The influence of specific and nonspecific gravi-receptors on nystagmic responses to angular acceleration.

    DOT National Transportation Integrated Search

    1969-10-01

    Data from several recent experiments indicate that the otoliths (detectors of linear acceleration) may exert regulatory effects on responses of the semicircular canals (detectors of angular acceleration). This study was designed to explore further th...

  4. Demonstrating the Direction of Angular Velocity in Circular Motion

    NASA Astrophysics Data System (ADS)

    Demircioglu, Salih; Yurumezoglu, Kemal; Isik, Hakan

    2015-09-01

    Rotational motion is ubiquitous in nature, from astronomical systems to household devices in everyday life to elementary models of atoms. Unlike the tangential velocity vector that represents the instantaneous linear velocity (magnitude and direction), an angular velocity vector is conceptually more challenging for students to grasp. In physics classrooms, the direction of an angular velocity vector is taught by the right-hand rule, a mnemonic tool intended to aid memory. A setup constructed for instructional purposes may provide students with a more easily understood and concrete method to observe the direction of the angular velocity. This article attempts to demonstrate the angular velocity vector using the observable motion of a screw mounted to a remotely operated toy car.

  5. Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force.

    PubMed

    Alizadeh Ebadi, Leyla; Çetin, Ebru

    2018-03-13

    The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles' isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball) participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A) 5 min jogging; (B) 5 min jogging followed by 15 s static stretching; (C) 5 min jogging followed by 30 s static stretching; (D) 5 min jogging, followed by static stretching for 45 s). Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.

  6. Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force

    PubMed Central

    Çetin, Ebru

    2018-01-01

    The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles’ isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball) participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A) 5 min jogging; (B) 5 min jogging followed by 15 s static stretching; (C) 5 min jogging followed by 30 s static stretching; (D) 5 min jogging, followed by static stretching for 45 s). Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.

  7. The effect of peculiar complex core balance training on isokinetic muscle functions of the knee and lumbus

    PubMed Central

    Lee, Myungsun; Han, Gunsoo

    2016-01-01

    [Purpose] This study aimed to investigate the effect of peculiar complex core balance training on the isokinetic muscle function of the knee joint and lumbus to provide fundamental data for establishing a training program that focuses on improving the performance and prevention of injury by developing the core and low extremity muscles. [Subjects and Methods] The participants in this study included a total of ten high school athletes involved in a throwing event for over five years. The subjects were randomly divided into two groups: The experimental group (N=5) and the control group (N=5). The experimental group underwent peculiar complex core balance training. [Results] According to the analysis of covariance, there was a significant effect of peculiar complex core balance training. Therefore, the isokinetic muscle function of the knee joint and lumbus in the experimental group participating in peculiar complex core balance training was significantly increased compared to the control group. [Conclusion] It is concluded that peculiar complex core balance training had a positive effect on the isokinetic muscle function of the knee and lumbus in throwing event athletes. PMID:27190470

  8. Nonparetic Knee Extensor Strength Is the Determinant of Exercise Capacity of Community-Dwelling Stroke Survivors

    PubMed Central

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    Objective. To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. Design. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. Results. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO2 peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Conclusions. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living. PMID:25197712

  9. Nonparetic knee extensor strength is the determinant of exercise capacity of community-dwelling stroke survivors.

    PubMed

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO₂ peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living.

  10. Addressing Angular Single-Event Effects in the Estimation of On-Orbit Error Rates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, David S.; Swift, Gary M.; Wirthlin, Michael J.

    2015-12-01

    Our study describes complications introduced by angular direct ionization events on space error rate predictions. In particular, prevalence of multiple-cell upsets and a breakdown in the application of effective linear energy transfer in modern-scale devices can skew error rates approximated from currently available estimation models. Moreover, this paper highlights the importance of angular testing and proposes a methodology to extend existing error estimation tools to properly consider angular strikes in modern-scale devices. Finally, these techniques are illustrated with test data provided from a modern 28 nm SRAM-based device.

  11. Discussion about different cut-off values of conventional hamstring-to-quadriceps ratio used in hamstring injury prediction among professional male football players

    PubMed Central

    Michałowska, Martyna; Walczak, Tomasz; Owen, Adam; Grabski, Jakub Krzysztof; Pyda, Andrzej; Piontek, Tomasz; Kotwicki, Tomasz

    2017-01-01

    Objective To measure the sensitivity and specificity of differences cut-off values for isokinetic Hcon/Qcon ratio in order to improve the capacity to evaluate (retrospectively) the injury of hamstring muscles in professional soccer screened with knee isokinetic tests. Design Retrospective study. Methods Medical and biomechanical data of professional football players playing for the same team for at least one season between 2010 and 2016 were analysed. Hamstring strain injury cases and the reports generated via isokinetic testing were investigated. Isokinetic concentric(con) hamstring(H) and quadriceps(Q) absolute strength in addition with Hcon/Qcon ratio were examined for the injured versus uninjured limbs among injured players, and for the injured and non-injured players. 2 x 2 contingency table was used for comparing variables: predicted injured or predicted uninjured with actual injured or actual uninjured. Sensitivity, specificity, accuracy, positive and negative predictive values, and positive and negative likelihood ratio were calculated for three different cut-off values (0.47 vs. 0.6 vs. 0.658) to compare the discriminative power of an isokinetic test, whilst examining the key value of Hcon/Qcon ratio which may indicate the highest level of ability to predispose a player to injury. McNemar’s chi2 test with Yates’s correction was used to determine agreement between the tests. PQStat software was used for all statistical analysis, and an alpha level of p <0.05 was used for all statistical comparisons. Results 340 isokinetic test reports on both limbs of 66 professional soccer players were analysed. Eleven players suffered hamstring injuries during the analysed period. None of these players sustained recurrence of hamstring injury. One player sustained hamstring strain injury on both legs, thus the total number of injuries was 12. Application of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic test used as a tool for muscle injury detection. The use of 0.47 of Hcon/Qcon as a discriminate value resulted in significantly lower sensitivity when compared to 0.658 threshold (sensitivity of 16.7% vs. 91.7%, respectively; t = 6.125,p = 0.0133). Calculated values of specificity (when three different cut-off were applied) were also significantly different. Threshold of 0.6 of Hcon/Qcon resulted with significantly lower specificity compared to 0.47 value (specificity of 46.9% vs. 94.5%, respectively; t = 153.0,p<0.0001), and significantly higher specificity when compared to 0.658 (specificity of 46.9% vs. 24.1%, respectively; t = 229.0, p<0.0001). Conclusion The use of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic testing. The interpretation of usefulness of isokinetic test as a screening tool in a group of male professional football players to predict hamstring injury occurrence within the next 12 months might be therefore significantly biased due to the different threshold values of Hcon/Qcon. Using one “normative” value as a cut-off (e.g. 0.47 or 0.60, or 0.658) to quantify soccer players (or not) to the group with a higher risk of knee injury might result in biased outcomes due to the natural strength asymmetry that is observed within the group of soccer players. PMID:29216241

  12. Discussion about different cut-off values of conventional hamstring-to-quadriceps ratio used in hamstring injury prediction among professional male football players.

    PubMed

    Grygorowicz, Monika; Michałowska, Martyna; Walczak, Tomasz; Owen, Adam; Grabski, Jakub Krzysztof; Pyda, Andrzej; Piontek, Tomasz; Kotwicki, Tomasz

    2017-01-01

    To measure the sensitivity and specificity of differences cut-off values for isokinetic Hcon/Qcon ratio in order to improve the capacity to evaluate (retrospectively) the injury of hamstring muscles in professional soccer screened with knee isokinetic tests. Retrospective study. Medical and biomechanical data of professional football players playing for the same team for at least one season between 2010 and 2016 were analysed. Hamstring strain injury cases and the reports generated via isokinetic testing were investigated. Isokinetic concentric(con) hamstring(H) and quadriceps(Q) absolute strength in addition with Hcon/Qcon ratio were examined for the injured versus uninjured limbs among injured players, and for the injured and non-injured players. 2 x 2 contingency table was used for comparing variables: predicted injured or predicted uninjured with actual injured or actual uninjured. Sensitivity, specificity, accuracy, positive and negative predictive values, and positive and negative likelihood ratio were calculated for three different cut-off values (0.47 vs. 0.6 vs. 0.658) to compare the discriminative power of an isokinetic test, whilst examining the key value of Hcon/Qcon ratio which may indicate the highest level of ability to predispose a player to injury. McNemar's chi2 test with Yates's correction was used to determine agreement between the tests. PQStat software was used for all statistical analysis, and an alpha level of p <0.05 was used for all statistical comparisons. 340 isokinetic test reports on both limbs of 66 professional soccer players were analysed. Eleven players suffered hamstring injuries during the analysed period. None of these players sustained recurrence of hamstring injury. One player sustained hamstring strain injury on both legs, thus the total number of injuries was 12. Application of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic test used as a tool for muscle injury detection. The use of 0.47 of Hcon/Qcon as a discriminate value resulted in significantly lower sensitivity when compared to 0.658 threshold (sensitivity of 16.7% vs. 91.7%, respectively; t = 6.125,p = 0.0133). Calculated values of specificity (when three different cut-off were applied) were also significantly different. Threshold of 0.6 of Hcon/Qcon resulted with significantly lower specificity compared to 0.47 value (specificity of 46.9% vs. 94.5%, respectively; t = 153.0,p<0.0001), and significantly higher specificity when compared to 0.658 (specificity of 46.9% vs. 24.1%, respectively; t = 229.0, p<0.0001). The use of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic testing. The interpretation of usefulness of isokinetic test as a screening tool in a group of male professional football players to predict hamstring injury occurrence within the next 12 months might be therefore significantly biased due to the different threshold values of Hcon/Qcon. Using one "normative" value as a cut-off (e.g. 0.47 or 0.60, or 0.658) to quantify soccer players (or not) to the group with a higher risk of knee injury might result in biased outcomes due to the natural strength asymmetry that is observed within the group of soccer players.

  13. Mechanical behaviour of hamstring muscles in low-back pain patients and control subjects.

    PubMed

    Tafazzoli, F; Lamontagne, M

    1996-01-01

    The purpose of this study was to measure and compare the passive elastic moment, the stiffness and the damping coefficient of the hip joint, as functions of the hip and knee joint angles in men with and without low-back pain. Two conventional tests, the straight-leg-raising test and the trunk forward flexion, were also performed and compared between these subjects. The passive elastic moment was measured using an isokinetic device in the passive mode. This device raised the lower limb from the horizontal position to the straight-leg-raising angle at a slow and constant angular velocity. A custom-made splint connected with the lever arm of the isokinetic device maintained the knee in extension and the ankle in the neutral position. The damping coefficient of the hip joint was measured for 0, 15, 45, 60, 75 and 90% of straight leg raising angle of each subject, using the suspension method based on small oscillation theory. To ensure that muscles were inactive during the passive hip moment tests, muscle activity was monitored with surface EMG. The stiffness was computed as the ratio of the change in passive elastic moment to the change in the hip angle. The passive elastic moment, the stiffness and the normalized trunk flexion were significantly different between the two groups respectively. There was, however, no difference between the two groups in the results of straight-leg-raise and damping coefficient of the hip. The passive elastic moment was a nonlinear function of the hip flexion angle and showed large intersubject differences, especially as the joint limit was approached. The damping coefficient was a polynomial function of the hip flexion angle. The measured variables were analysed using a discriminant function and it was shown that the two groups were clearly discriminable in a meaningful manner.

  14. Can platelet-rich plasma have a role in Achilles tendon surgical repair?

    PubMed

    De Carli, Angelo; Lanzetti, Riccardo Maria; Ciompi, Alessandro; Lupariello, Domenico; Vadalà, Antonio; Argento, Giuseppe; Ferretti, Andrea; Vulpiani, M C; Vetrano, M

    2016-07-01

    Our hypothesis was that the Achilles tendon healing process after surgical treatment would be promoted by PRP with a faster return to sports activities. Thirty patients with Achilles tendon rupture and surgically treated with a combined mini-open and percutaneous technique were prospectively enroled in the study. Patients were alternately case-by-case assigned to Group A (control group; 15 patients) or Group B (study group; 15 patients). In Group B, PRP was locally infiltrated both during surgery and 14 days after surgery. Patients in both groups were followed up at 1, 3, 6 and 24 months post-operatively via physical examination, VAS, FAOS and VISA-A scales; ultrasonography (US) and MRI were also conducted at one and 6 months; at the 6-month follow-up, isokinetic and jumping capacity tests were also performed. The VAS, FAOS and VISA-A scale showed no difference between the two groups at 1, 3, 6 and 24 months post-operatively. Isokinetic evaluation showed no differences at both angular speeds. Jumping evaluation showed no difference at 6 months. Also US evaluation showed no differences. MRI data analysis before administration of gadolinium did not reveal significant differences between the two groups. Moreover, after intravenous injection of gadolinium, patients in Group B showed signal enhancement in 30 % of patients compared to 80 % in Group A at 6 months, as indirect evidence of better tendon remodelling (P < 0.05). A substantial equivalence in structural and functional results in Achilles tendon ruptures surgically treated with and without addition of PRP is shown by present study. Clinical results, morphological features and jumping capability were similar in both groups. The addition of PRP to the surgical treatment of Achilles tendon rupture does not appear to offer superior clinical and functional results. IV.

  15. [Does transcutaneous electrical nerve stimulation or therapeutic ultrasound increase the effectiveness of exercise for knee osteoarthritis: a randomized controlled study].

    PubMed

    Eyigör, Sibel; Karapolat, Hale; Ibisoğlu, Uğur; Durmaz, Berrin

    2008-01-01

    The aim of this study was to determine if transcutaneous electrical nerve stimulation (TENS) or therapeutic ultrasound (US) increase the effectiveness of exercise on pain, function, muscle strength and quality of life for knee osteoarthritis (OA). Forty-five patients with primary knee OA diagnosis according to American College Rheumatology criteria were sequentially divided into 3 random groups. The patients in group 1 received TENS (with superficial heat and exercise), group 2 received US (with superficial heat and exercise), and group 3 acted as controls (superficial heat and exercise). Outcome measures were included as visual analog scale (VAS), a 20-meter walking test, Lequesne index, WOMAC scores, isokinetic muscle testing, and the Short Form 36 (SF 36). All treatment groups, physical modalities were carried out for a total fifteen sessions. All of the patients were subjected to six weeks of exercise program. All of the treatment groups had significant improvement on activity VAS, 20 meter walking test, Lequesne index, WOMAC scores, and most of the sub-scores of SF36 when compared with their initial status (p<0.05). All of the treatment groups, a significant muscle strength gain in most of the angular velocity in knee extensor PT values after the treatment (p<0.05). However there was no statistically significant difference after the treatment between the all treatment groups (p>0.05). All of the treatment groups were effective on pain, function, muscle strength and quality of life in patients with knee OA. Statistically significant differences could not be found between the treatment groups. The exercise program, as it is cheaper, more easily performed and efficient, may be preferable for the treatment of knee OA. It is difficult to say, TENS or US could increase the effectiveness of isokinetic exercise for pain, function, muscle strength and quality of life of knee OA in this study.

  16. Calibration of EMG to force for knee muscles is applicable with submaximal voluntary contractions.

    PubMed

    Doorenbosch, Caroline A M; Joosten, Annemiek; Harlaar, Jaap

    2005-08-01

    In this study, the influence of using submaximal isokinetic contractions about the knee compared to maximal voluntary contractions as input to obtain the calibration of an EMG-force model for knee muscles is investigated. Isokinetic knee flexion and extension contractions were performed by healthy subjects at five different velocities and at three contraction levels (100%, 75% and 50% of MVC). Joint angle, angular velocity, joint moment and surface EMG of five knee muscles were recorded. Individual calibration values were calculated according to [C.A.M. Doorenbosch, J. Harlaar, A clinically applicable EMG-force model to quantify active stabilization of the knee after a lesion of the anterior cruciate ligament, Clinical Biomechanics 18 (2003) 142-149] for each contraction level. First, the output of the model, calibrated with the 100% MVC was compared to the actually exerted net knee moment at the dynamometer. Normalized root mean square errors were calculated [A.L. Hof, C.A.N. Pronk, J.A. van Best, Comparison between EMG to force processing and kinetic analysis for the calf muscle moment in walking and stepping, Journal of Biomechanics 20 (1987) 167-187] to compare the estimated moments with the actually exerted moments. Mean RMSD errors ranged from 0.06 to 0.21 for extension and from 0.12 to 0.29 for flexion at the 100% trials. Subsequently, the calibration results of the 50% and 75% MVC calibration procedures were used. A standard signal, representing a random EMG level was used as input in the EMG force model, to compare the three models. Paired samples t-tests between the 100% MVC and the 75% MVC and 50% MVC, respectively, showed no significant differences (p>0.05). The application of submaximal contractions of larger than 50% MVC is suitable to calibrate a simple EMG to force model for knee extension and flexion. This means that in clinical practice, the EMG to force model can be applied by patients who cannot exert maximal force.

  17. Comparison between parameters of muscle performance and inflammatory biomarkers of non-sarcopenic and sarcopenic elderly women.

    PubMed

    Lustosa, Lygia Paccini; Batista, Patrícia Parreira; Pereira, Daniele Sirineu; Pereira, Leani Souza Máximo; Scianni, Aline; Ribeiro-Samora, Giane Amorim

    2017-01-01

    Sarcopenia is a multifactorial geriatric syndrome with complex interrelationships. Increased plasma levels of inflammatory mediators increase the catabolic stimuli of the musculature, thereby causing a decrease in mass and muscular function. The objective of this study was to compare the performance of the knee extensors test (by isokinetic dynamometer) and plasma levels of interleukin-6 (IL-6) and soluble receptors of tumor necrosis factor alpha (sTNFR1) between sarcopenics and non-sarcopenics community-dwelling elderly women residents of Brazil. The diagnosis of sarcopenia included measurements of body composition (by densitometry with dual energy source of X-ray), handgrip strength (by Jamar ® dynamometer), and the usual gait velocity according to the recommendations of the European Working Group on Sarcopenia in Older People. In both sarcopenics and non-sarcopenics elderly women, we evaluated the muscle function by knee extensors test (using an isokinetic dynamometer Byodex System 4 Pro ® ) at angular speeds of 60°/s and 180°/s) and also we evaluated the plasma concentrations of IL-6 and sTNFR1. Comparisons of muscle performance between groups were carried out using mixed factorial ANOVA with post hoc Bonferroni test; sTNFR1 and IL-6 variables were analyzed by applying Mann-Whitney U test. Statistical differences were observed between groups regarding muscle power ( P =0.01), total work adjusted to body weight ( P =0.01) at a rate of 180°/s, and plasma levels of sTNFR1 ( P =0.01). Sarcopenic elder women showed lower performance of the lower limbs, especially at a higher speed, predisposing these older women to greater vulnerability in functional activities that require agility and postural stability. Plasma levels of sTNFR1 were higher for non-sarcopenics elderlies. However, due to the observational nature of the study, it was impossible to infer causality among the variables surveyed.

  18. An Inventory on Rotational Kinematics of a Particle: Unravelling Misconceptions and Pitfalls in Reasoning

    ERIC Educational Resources Information Center

    Mashood, K. K.; Singh, Vijay A.

    2012-01-01

    Student difficulties regarding the angular velocity ([image omitted]) and angular acceleration ([image omitted]) of a particle have remained relatively unexplored in contrast to their linear counterparts. We present an inventory comprising multiple choice questions aimed at probing misconceptions and eliciting ill-suited reasoning patterns. The…

  19. Demonstrating the Direction of Angular Velocity in Circular Motion

    ERIC Educational Resources Information Center

    Demircioglu, Salih; Yurumezoglu, Kemal; Isik, Hakan

    2015-01-01

    Rotational motion is ubiquitous in nature, from astronomical systems to household devices in everyday life to elementary models of atoms. Unlike the tangential velocity vector that represents the instantaneous linear velocity (magnitude and direction), an angular velocity vector is conceptually more challenging for students to grasp. In physics…

  20. Application of Linearized Kalman Filter-Smoother to Aircraft Trajectory Estimation.

    DTIC Science & Technology

    1988-06-01

    the report). The kinematic relationships between wind-axis Euler angles and angular rates are given below (Etkin, 1972: 150): q w OS r w s i n* * (4...I values, and those for RP-2 were chosen in order to explore less accurate range measurements combined with more accurate angular measurements. This...was of interest because of the uncertainty in position introduced by large angular measurement uncertainties at long ranges. Finally, radar models RR

  1. State Derivation of a 12-Axis Gyroscope-Free Inertial Measurement Unit

    PubMed Central

    Lu, Jau-Ching; Lin, Pei-Chun

    2011-01-01

    The derivation of linear acceleration, angular acceleration, and angular velocity states from a 12-axis gyroscope-free inertial measurement unit that utilizes four 3-axis accelerometer measurements at four distinct locations is reported. Particularly, a new algorithm which derives the angular velocity from its quadratic form and derivative form based on the context-based interacting multiple model is demonstrated. The performance of the system was evaluated under arbitrary 3-dimensional motion. PMID:22163791

  2. Single-Leg Hop Test Performance and Isokinetic Knee Strength After Anterior Cruciate Ligament Reconstruction in Athletes

    PubMed Central

    Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki

    2017-01-01

    Background: Isokinetic strength and hop tests are commonly used to assess athletes’ readiness to return to sport after knee surgery. Purpose/Hypothesis: The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation (r). Results: The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s (P = .03), flexion total work/body weight at 180 deg/s (P = .04), and flexion peak torque/body weight at 300 deg/s (P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s (r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s (r = –0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types. Conclusion: The single-leg hop tests and isokinetic strength measurements were both useful for a bilateral comparison of knee functional performance and strength. Knee flexion strength deficits and flexion-to-extension ratios seemed to be correlated with single-leg hop test performance. There was no difference in postoperative hop test performance or knee strength according to graft type. PMID:29164167

  3. Linear stability analysis of collective neutrino oscillations without spurious modes

    NASA Astrophysics Data System (ADS)

    Morinaga, Taiki; Yamada, Shoichi

    2018-01-01

    Collective neutrino oscillations are induced by the presence of neutrinos themselves. As such, they are intrinsically nonlinear phenomena and are much more complex than linear counterparts such as the vacuum or Mikheyev-Smirnov-Wolfenstein oscillations. They obey integro-differential equations, for which it is also very challenging to obtain numerical solutions. If one focuses on the onset of collective oscillations, on the other hand, the equations can be linearized and the technique of linear analysis can be employed. Unfortunately, however, it is well known that such an analysis, when applied with discretizations of continuous angular distributions, suffers from the appearance of so-called spurious modes: unphysical eigenmodes of the discretized linear equations. In this paper, we analyze in detail the origin of these unphysical modes and present a simple solution to this annoying problem. We find that the spurious modes originate from the artificial production of pole singularities instead of a branch cut on the Riemann surface by the discretizations. The branching point singularities on the Riemann surface for the original nondiscretized equations can be recovered by approximating the angular distributions with polynomials and then performing the integrals analytically. We demonstrate for some examples that this simple prescription does remove the spurious modes. We also propose an even simpler method: a piecewise linear approximation to the angular distribution. It is shown that the same methodology is applicable to the multienergy case as well as to the dispersion relation approach that was proposed very recently.

  4. The angular structure of ONC201, a TRAIL pathway-inducing compound, determines its potent anti-cancer activity

    PubMed Central

    Wagner, Jessica; Kline, Christina Leah; Pottorf, Richard S.; Nallaganchu, Bhaskara Rao; Olson, Gary L.; Dicker, David T.; Allen, Joshua E.; El-Deiry, Wafik S.

    2014-01-01

    We previously identified TRAIL-inducing compound 10 (TIC10), also known as NSC350625 or ONC201, from a NCI chemical library screen as a small molecule that has potent anti-tumor efficacy and a benign safety profile in preclinical cancer models. The chemical structure that was originally published by Stahle, et. al. in the patent literature was described as an imidazo[1,2-a]pyrido[4,3-d]pyrimidine derivative. The NCI and others generally accepted this as the correct structure, which was consistent with the mass spectrometry analysis outlined in the publication by Allen et. al. that first reported the molecule's anticancer properties. A recent publication demonstrated that the chemical structure of ONC201 material from the NCI is an angular [3,4-e] isomer of the originally disclosed, linear [4,3-d] structure. Here we confirm by NMR and X-ray structural analysis of the dihydrochloride salt form that the ONC201 material produced by Oncoceutics is the angular [3,4-e] structure and not the linear structure originally depicted in the patent literature and by the NCI. Similarly, in accordance with our biological evaluation, the previously disclosed anti-cancer activity is associated with the angular structure and not the linear isomer. Together these studies confirm that ONC201, produced by Oncoceutics or obtained from the NCI, possesses an angular [3,4-e] structure that represents the highly active anti-cancer compound utilized in prior preclinical studies and now entering clinical trials in advanced cancers. PMID:25587031

  5. The angular structure of ONC201, a TRAIL pathway-inducing compound, determines its potent anti-cancer activity.

    PubMed

    Wagner, Jessica; Kline, Christina Leah; Pottorf, Richard S; Nallaganchu, Bhaskara Rao; Olson, Gary L; Dicker, David T; Allen, Joshua E; El-Deiry, Wafik S

    2014-12-30

    We previously identified TRAIL-inducing compound 10 (TIC10), also known as NSC350625 or ONC201, from a NCI chemical library screen as a small molecule that has potent anti-tumor efficacy and a benign safety profile in preclinical cancer models. The chemical structure that was originally published by Stahle, et. al. in the patent literature was described as an imidazo[1,2-a]pyrido[4,3-d]pyrimidine derivative. The NCI and others generally accepted this as the correct structure, which was consistent with the mass spectrometry analysis outlined in the publication by Allen et. al. that first reported the molecule's anticancer properties. A recent publication demonstrated that the chemical structure of ONC201 material from the NCI is an angular [3,4-e] isomer of the originally disclosed, linear [4,3-d] structure. Here we confirm by NMR and X-ray structural analysis of the dihydrochloride salt form that the ONC201 material produced by Oncoceutics is the angular [3,4-e] structure and not the linear structure originally depicted in the patent literature and by the NCI. Similarly, in accordance with our biological evaluation, the previously disclosed anti-cancer activity is associated with the angular structure and not the linear isomer. Together these studies confirm that ONC201, produced by Oncoceutics or obtained from the NCI, possesses an angular [3,4-e] structure that represents the highly active anti-cancer compound utilized in prior preclinical studies and now entering clinical trials in advanced cancers.

  6. Effects of nine weeks isokinetic training on power, golf kinematics, and driver performance in pre-elite golfers.

    PubMed

    Parker, James; Lagerhem, Charlie; Hellström, John; Olsson, M Charlotte

    2017-01-01

    It has previously been shown that isotonic strength training can improve driver performance among golfers, though few studies have investigated effects of strength training on swing kinematics together with driver performance. In this study we investigated whether isokinetic rotational training could improve driver performance and swing kinematic variables amongst elite golfers. Twenty competitive pre-elite golfers (handicap better than -3.0), 13 men and 7 women, were split into two groups, one group received the isokinetic power training (IK) alongside their normal isotonic pre-season strength-training and the other group continued with their normal isotonic pre-season strength-training regime (IT). The IK group completed 12 sessions of isokinetic power training on a standing rotation exercise (10% body weight at 1 m/s) and barbell squat (25 kg plus 10% body weight at 0.5 m/s). The IT group continued with their normal isotonic pre-season strength-training regime. Participants were tested for rotational power, lower body power, golf swing kinematics, and driver performance before and after a nine-week training period. After the nine-week training period both the IK and the IT groups increased their dominant side rotational force and power (effect sizes between 0.50-0.96) and magnitude based inference indicated that IK had a likely (> 80%) more beneficial increase in dominant side rotational force and power. For swing kinematics, IK had a likely (> 80%) more beneficial improvement in lead arm speed and acceleration compared to the IT group. For driver performance, IK had a possible (65%) beneficial effect on ball speed and likely (78%) beneficial effect on carry distance when compared to IT, whereas neither of the groups improved club head speed. In the present study on pre-elite golfers we found that 9 weeks of isokinetic training increased seated rotational force and power, peak arm speed and arm acceleration, ball speed, and carry distance more compared to isotonic training. Even though isokinetic training did not increase CHS, it did result in greater carry distance.

  7. INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

    PubMed

    Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J

    2016-02-01

    Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p < .05) as velocity increased whereas AP increased as velocity increased. PF and AP during pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and AP compared to pulling can be attributed to the muscles involved and the frequency that pushing patterns are used during functional activities. 3.

  8. Factors influencing perceived angular velocity.

    PubMed

    Kaiser, M K; Calderone, J B

    1991-11-01

    The assumption that humans are able to perceive and process angular kinematics is critical to many structure-from-motion and optical flow models. The current studies investigate this sensitivity, and examine several factors likely to influence angular velocity perception. In particular, three factors are considered: (1) the extent to which perceived angular velocity is determined by edge transitions of surface elements, (2) the extent to which angular velocity estimates are influenced by instantaneous linear velocities of surface elements, and (3) whether element-velocity effects are related to three-dimensional (3-D) tangential velocities or to two-dimensional (2-D) image velocities. Edge-transition rate biased angular velocity estimates only when edges were highly salient. Element velocities influenced perceived angular velocity; this bias was related to 2-D image velocity rather than 3-D tangential velocity. Despite these biases, however, judgments were most strongly determined by the true angular velocity. Sensitivity to this higher order motion parameter was surprisingly good, for rotations both in depth (y-axis) and parallel to the line of sight (z-axis).

  9. The vestibulo-ocular reflex of the squirrel monkey during eccentric rotation and roll tilt

    NASA Technical Reports Server (NTRS)

    Merfeld, D. M.; Young, L. R.

    1995-01-01

    The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in six male squirrel monkeys during eccentric rotation. Monkeys were rotated in the dark at a constant velocity of 200 degrees/s (centrally or 79 cm off axis) with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's orientation (facing-motion or back-to-motion) had a dramatic influence on the VOR. These experiments show that: (a) the axis of eye rotation always shifted toward alignment with gravito-inertial force; (b) the peak value of horizontal slow phase eye velocity was greater with the monkey facing-motion than with back-to-motion; and (c) the time constant of horizontal eye movement decay was smaller with the monkey facing-motion than with back-to-motion. All of these findings were statistically significant and consistent across monkeys. In another set of tests, the same monkeys were rapidly tilted about their naso-occipital (roll) axis. Tilted orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the angular rotation, no consistent eye velocity response was observed during or following the tilt for any of the six monkeys. The absence of any eye movement response following tilt weighs against the possibility that translational linear VOR responses are due to simple high-pass filtering of the otolith signals. The VOR response during eccentric rotation was divided into the more familiar angular VOR and linear VOR components. The angular component is known to depend upon semicircular canal dynamics and central influences. The linear component of the response decays rapidly with a mean duration of only 6.6 s, while the axis of eye rotation rapidly aligns (< 10 s) with gravito-inertial force. These results are consistent with the hypothesis that the measurement of gravito-inertial force by the otolith organs is resolved into central estimates of linear acceleration and gravity, such that the central estimate of gravitational force minus the central estimate of linear acceleration approximately equals the otolith measurement of gravito-inertial force.

  10. Low intensity vibration of ankle muscles improves balance in elderly persons at high risk of falling

    PubMed Central

    Toosizadeh, Nima; Mohler, Jane

    2018-01-01

    In our study we examined postural performance of young healthy persons (HY), elderly healthy persons (HE), and elderly persons at high risk of falling (FR). Anterio-posterior (AP) and medio-lateral (ML) ankle and hip angular deviations, as well as linear displacements of the center of mass (COM) were assessed in persons standing with eyes either open or closed, while none, and 40 and 30 Hz vibrations were applied bilaterally to the ankle muscle gastrocnemius. During quiet standing with eyes open, balance parameters in FR group differed from those in healthy groups. ML ankle and hip angular deviations, as well as COM linear displacements were noticeably larger in FR group. During quiet standing with eyes closed, all balance parameters in participants of all groups had a clear trend to increase. During standing with eyes open, 40 Hz vibration increased all but one balance parameter within HY group, ankle angular deviations in HE group, but none in FR group. In response to 30 Hz vibration, only ankle angular deviations and COM linear displacements increased in HY group. There were no changes in both elderly groups. During standing with eyes closed, 40 and 30 Hz vibrations did not produce consistent changes in balance parameters in HY and HE groups. In FR persons, 40 Hz vibration did not change balance parameters. However, in FR groups, 30 Hz vibration decreased ankle and hip angular deviations, and COM linear displacements. The major result of the study is a finding that low intensity vibration of ankle muscles makes balance better in elderly persons at high risk of falling. This result is clinically relevant because it suggests that applying mild vibration to ankle muscles while standing and walking might benefit elderly persons, improving their postural performance and reducing a risk of unexpected falls. PMID:29579098

  11. Effects of rest interval on isokinetic strength and functional performance after short-term high intensity training.

    PubMed

    Pincivero, D M; Lephart, S M; Karunakara, R G

    1997-09-01

    The ability to maximally generate active muscle tension during resistance training has been established to be a primary determinant for strength development. The influence of intrasession rest intervals may have a profound effect on strength gains subsequent to short-term high intensity training. The purpose of this study was to examine the effects of rest interval on strength and functional performance after four weeks of isokinetic training. Fifteen healthy college aged individuals were randomly assigned to either a short rest interval group (group 1, n = 8) or a long rest interval group (group 2, n = 7). Subjects were evaluated for quadriceps and hamstring isokinetic strength at 60 (five repetitions) and 180 (30 repetitions) degrees/second and functional performance with the single leg hop for distance test. One leg of each subject was randomly assigned to a four week, three days/week isokinetic strength training programme for concentric knee extension and flexion performed at 90 degrees/second. Subjects in group 1 received a 40 second rest interval in between exercise sets, whereas subjects in group 2 received a 160 second rest period. A two factor analysis of variance for the pre-test--post-test gain scores (%) showed significantly greater improvements for isokinetic hamstring total work and average power at 180 degrees/second for the trained limb of subjects in group 2 than their contralateral non-trained limb and the subjects in group 1. Significantly greater improvements for the single leg hop for distance were also found for the trained limbs of subjects in both groups as compared with the non-trained limbs. The findings indicate that a relatively longer intrasession rest period resulted in a greater improvement in hamstring muscle strength during short term high intensity training.

  12. Association with isokinetic ankle strength measurements and normal clinical muscle testing in sciatica patients.

    PubMed

    Ustun, N; Erol, O; Ozcakar, L; Ceceli, E; Ciner, O Akar; Yorgancioglu, Z R

    2013-01-01

    Sensitive muscle strength tests are needed to measure muscle strength in the diagnosis and management of sciatica patients. The aim of this study was to assess the isokinetic muscle strength in sciatica patients' and control subjects' ankles that exhibited normal ankle muscle strength when measured clinically. Forty-six patients with L5 and/or S1 nerve compression, and whose age, sex, weight, and height matched 36 healthy volunteers, were recruited to the study. Heel-walking, toe-walking, and manual muscle testing were used to perform ankle dorsiflexion and plantar flexion strengths in clinical examination. Patients with normal ankle dorsiflexion and plantar flexion strengths assessed by manual muscle testing and heel-and toe-walking tests were included in the study. Bilateral isokinetic (concentric/concentric) ankle plantar-flexion-dorsiflexion measurements of the patients and controls were performed within the protocol of 30°/sec (5 repetitions). Peak torque and peak torque/body weight were obtained for each ankle motion of the involved limb at 30°/s speed. L5 and/or S1 nerve compression was evident in 46 patients (76 injured limbs). Mean disease duration was two years. The plantar flexion muscle strength of the patients was found to be lower than that of the controls (p=0.036). The dorsiflexion muscle strength of the patients was found to be the same as that of the controls (p=0.211). Isokinetic testing is superior to clinical muscle testing when evaluating ankle plantar flexion torque in sciatica patients. Therefore, isokinetic muscle testing may be helpful when deciding whether to place a patient into a focused rehabilitation program.

  13. Combined Effects of Lignosus rhinocerotis Supplementation and Resistance Training on Isokinetic Muscular Strength and Power, Anaerobic and Aerobic Fitness Level, and Immune Parameters in Young Males.

    PubMed

    Chen, Chee Keong; Hamdan, Nor Faeiza; Ooi, Foong Kiew; Wan Abd Hamid, Wan Zuraida

    2016-01-01

    This study investigated the effects of Lignosus rhinocerotis (LRS) supplementation and resistance training (RT) on isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters in young males. Participants were randomly assigned to four groups: Control (C), LRS, RT, and combined RT-LRS (RT-LRS). Participants in the LRS and RT-LRS groups consumed 500 mg of LRS daily for 8 weeks. RT was conducted 3 times/week for 8 weeks for participants in the RT and RT-LRS groups. The following parameters were measured before and after the intervention period: Anthropometric data, isokinetic muscular strength and power, and anaerobic and aerobic fitness. Blood samples were also collected to determine immune parameters. Isokinetic muscular strength and power were increased ( P < 0.05) in participants of both RT and RT-LRS groups. RT-LRS group had shown increases ( P < 0.05) in shoulder extension peak torque, shoulder flexion and extension average power, knee flexion peak torque, and knee flexion and extension average power. There were also increases ( P < 0.05) in anaerobic power and capacity and aerobic fitness in this group. Similarly, RT group had increases ( P < 0.05) in shoulder flexion average power, knee flexion and extension peak torque, and knee flexion and extension average power. In addition, increases ( P < 0.05) in anaerobic power and capacity, aerobic fitness, T lymphocytes (CD3 and CD4), and B lymphocytes (CD19) counts were observed in the RT group. RT elicited increased isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters among young males. However, supplementation with LRS during RT did not provide additive benefits.

  14. Olympic weightlifting and plyometric training with children provides similar or greater performance improvements than traditional resistance training.

    PubMed

    Chaouachi, Anis; Hammami, Raouf; Kaabi, Sofiene; Chamari, Karim; Drinkwater, Eric J; Behm, David G

    2014-06-01

    A number of organizations recommend that advanced resistance training (RT) techniques can be implemented with children. The objective of this study was to evaluate the effectiveness of Olympic-style weightlifting (OWL), plyometrics, and traditional RT programs with children. Sixty-three children (10-12 years) were randomly allocated to a 12-week control OWL, plyometric, or traditional RT program. Pre- and post-training tests included body mass index (BMI), sum of skinfolds, countermovement jump (CMJ), horizontal jump, balance, 5- and 20-m sprint times, isokinetic force and power at 60 and 300° · s(-1). Magnitude-based inferences were used to analyze the likelihood of an effect having a standardized (Cohen's) effect size exceeding 0.20. All interventions were generally superior to the control group. Olympic weightlifting was >80% likely to provide substantially better improvements than plyometric training for CMJ, horizontal jump, and 5- and 20-m sprint times, whereas >75% likely to substantially exceed traditional RT for balance and isokinetic power at 300° · s(-1). Plyometric training was >78% likely to elicit substantially better training adaptations than traditional RT for balance, isokinetic force at 60 and 300° · s(-1), isokinetic power at 300° · s(-1), and 5- and 20-m sprints. Traditional RT only exceeded plyometric training for BMI and isokinetic power at 60° · s(-1). Hence, OWL and plyometrics can provide similar or greater performance adaptations for children. It is recommended that any of the 3 training modalities can be implemented under professional supervision with proper training progressions to enhance training adaptations in children.

  15. Combined Effects of Lignosus rhinocerotis Supplementation and Resistance Training on Isokinetic Muscular Strength and Power, Anaerobic and Aerobic Fitness Level, and Immune Parameters in Young Males

    PubMed Central

    Chen, Chee Keong; Hamdan, Nor Faeiza; Ooi, Foong Kiew; Wan Abd Hamid, Wan Zuraida

    2016-01-01

    Background: This study investigated the effects of Lignosus rhinocerotis (LRS) supplementation and resistance training (RT) on isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters in young males. Methods: Participants were randomly assigned to four groups: Control (C), LRS, RT, and combined RT-LRS (RT-LRS). Participants in the LRS and RT-LRS groups consumed 500 mg of LRS daily for 8 weeks. RT was conducted 3 times/week for 8 weeks for participants in the RT and RT-LRS groups. The following parameters were measured before and after the intervention period: Anthropometric data, isokinetic muscular strength and power, and anaerobic and aerobic fitness. Blood samples were also collected to determine immune parameters. Results: Isokinetic muscular strength and power were increased (P < 0.05) in participants of both RT and RT-LRS groups. RT-LRS group had shown increases (P < 0.05) in shoulder extension peak torque, shoulder flexion and extension average power, knee flexion peak torque, and knee flexion and extension average power. There were also increases (P < 0.05) in anaerobic power and capacity and aerobic fitness in this group. Similarly, RT group had increases (P < 0.05) in shoulder flexion average power, knee flexion and extension peak torque, and knee flexion and extension average power. In addition, increases (P < 0.05) in anaerobic power and capacity, aerobic fitness, T lymphocytes (CD3 and CD4), and B lymphocytes (CD19) counts were observed in the RT group. Conclusions: RT elicited increased isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters among young males. However, supplementation with LRS during RT did not provide additive benefits. PMID:27833721

  16. Effect of Wiihabilitation on strength ratio of ankle muscles in adults

    PubMed Central

    Khalil, Aya A.; Mohamed, Ghada A.; El Rahman, Soheir M. Abd; Elhafez, Salam M.; Nassif, Nagui S.

    2016-01-01

    [Purpose] This study was conducted to investigate the effect of Wiihabilitation on the ankle dorsiflexion/plantar flexion strength ratio in adults. [Subjects and Methods] Thirty-two healthy male volunteers were randomly assigned to two equal groups (experimental and control). Participants in the experimental group received a Wiihabilitation training program for six weeks. Data were collected using a Biodex system 3 Isokinetic dynamometer. Peak torques of the dorsiflexors and plantar flexors were measured at an angular velocity of 60°/sec which in turn were used to derive the ankle dorsiflexion/plantar flexion strength ratio. [Results] The mean values of the ankle dorsiflexion/plantar flexion strength ratio decreased significantly between before and after the training in the experimental group, meanwhile there was no significant difference between before and after the training period in the control group . [Conclusion] Wiihabilitation has an impact on the ankle dorsiflexion/plantar flexion strength ratio, so it can be considered an effective training tool in terms of the ankle strength ratio. Thus, it could be recommended for both prevention and rehabilitation of ankle instability patients. PMID:27821951

  17. Effect of Wiihabilitation on strength ratio of ankle muscles in adults.

    PubMed

    Khalil, Aya A; Mohamed, Ghada A; El Rahman, Soheir M Abd; Elhafez, Salam M; Nassif, Nagui S

    2016-10-01

    [Purpose] This study was conducted to investigate the effect of Wiihabilitation on the ankle dorsiflexion/plantar flexion strength ratio in adults. [Subjects and Methods] Thirty-two healthy male volunteers were randomly assigned to two equal groups (experimental and control). Participants in the experimental group received a Wiihabilitation training program for six weeks. Data were collected using a Biodex system 3 Isokinetic dynamometer. Peak torques of the dorsiflexors and plantar flexors were measured at an angular velocity of 60°/sec which in turn were used to derive the ankle dorsiflexion/plantar flexion strength ratio. [Results] The mean values of the ankle dorsiflexion/plantar flexion strength ratio decreased significantly between before and after the training in the experimental group, meanwhile there was no significant difference between before and after the training period in the control group . [Conclusion] Wiihabilitation has an impact on the ankle dorsiflexion/plantar flexion strength ratio, so it can be considered an effective training tool in terms of the ankle strength ratio. Thus, it could be recommended for both prevention and rehabilitation of ankle instability patients.

  18. Vectorial structures of linear-polarized Butterfly-Gauss vortex beams in the far zone

    NASA Astrophysics Data System (ADS)

    Cheng, Ke; Zhou, Yan; Lu, Gang; Yao, Na; Zhong, Xianqiong

    2018-05-01

    By introducing the Butterfly catastrophe to optics, the far-zone vectorial structures of Butterfly-Gauss beam with vortex and non-vortex are studied using the angular spectrum representation and stationary phase method. The influence of topological charge, linear-polarized angle, off-axis distance and scaling length on the far-zone vectorial structures, especially in the Poynting vector and angular momentum density of the corresponding beam is emphasized. The results show that the embedded optical vortex at source plane lead to special dark zones in the far zone, where the number of dark zone equals the absolute value of topological charge of optical vortex. Furthermore, the symmetry and direction of the special dark zones can be controlled by off-axis distance and scaling length, respectively. The linear-polarized angle adjusts only the Poynting vectors of TE and TM terms, but it does not affect those of whole beam. Finally, the vectorial expressions also indicate that the total angular momentum density is certainly zero owing to the far-zone stable structures rather than rotation behaviors.

  19. Commercial video frame rates can produce reliable results for both normal and CP spastic gait's spatiotemporal, angular, and linear displacement variables.

    PubMed

    Nikodelis, Thomas; Moscha, Dimitra; Metaxiotis, Dimitris; Kollias, Iraklis

    2011-08-01

    To investigate what sampling frequency is adequate for gait, the correlation of spatiotemporal parameters and the kinematic differences, between normal and CP spastic gait, for three sampling frequencies (100 Hz, 50 Hz, 25 Hz) were assessed. Spatiotemporal, angular, and linear displacement variables in the sagittal plane along with their 1st and 2nd derivatives were analyzed. Spatiotemporal stride parameters were highly correlated among the three sampling frequencies. The statistical model (2 × 3 ANOVA) gave no interactions between the factors group and frequency, indicating that group differences were invariant of sampling frequency. Lower frequencies led to smoother curves for all the variables, with a loss of information though, especially for the 2nd derivatives, having a homologous effect as the one of oversmoothing. It is proposed that in the circumstance that only spatiotemporal stride parameters, as well as angular and linear displacements are to be used, in gait reports, then commercial video camera speeds (25/30 Hz, 50/60 Hz when deinterlaced) can be considered as a low-cost solution to produce acceptable results.

  20. General relativistic corrections to the weak lensing convergence power spectrum

    NASA Astrophysics Data System (ADS)

    Giblin, John T.; Mertens, James B.; Starkman, Glenn D.; Zentner, Andrew R.

    2017-11-01

    We compute the weak lensing convergence power spectrum, Cℓκκ, in a dust-filled universe using fully nonlinear general relativistic simulations. The spectrum is then compared to more standard, approximate calculations by computing the Bardeen (Newtonian) potentials in linearized gravity and partially utilizing the Born approximation. We find corrections to the angular power spectrum amplitude of order ten percent at very large angular scales, ℓ˜2 - 3 , and percent-level corrections at intermediate angular scales of ℓ˜20 - 30 .

  1. Mechanical design and driving mechanism of an isokinetic functional electrical stimulation-based leg stepping trainer.

    PubMed

    Hamzaid, N A; Fornusek, C; Ruys, A; Davis, G M

    2007-12-01

    The mechanical design of a constant velocity (isokinetic) leg stepping trainer driven by functional electrical stimulation-evoked muscle contractions was the focus of this paper. The system was conceived for training the leg muscles of neurologically-impaired patients. A commercially available slider crank mechanism for elliptical stepping exercise was adapted to a motorized isokinetic driving mechanism. The exercise system permits constant-velocity pedalling at cadences of 1-60 rev x min(-1). The variable-velocity feature allows low pedalling forces for individuals with very weak leg muscles, yet provides resistance to higher pedalling effort in stronger patients. In the future, the system will be integrated with a computer-controlled neuromuscular stimulator and a feedback control unit to monitor training responses of spinal cord-injured, stroke and head injury patients.

  2. Three-dimensional repositioning accuracy of semiadjustable articulator cast mounting systems.

    PubMed

    Tan, Ming Yi; Ung, Justina Youlin; Low, Ada Hui Yin; Tan, En En; Tan, Keson Beng Choon

    2014-10-01

    In spite of its importance in prosthesis precision and quality, the 3-dimensional repositioning accuracy of cast mounting systems has not been reported in detail. The purpose of this study was to quantify the 3-dimensional repositioning accuracy of 6 selected cast mounting systems. Five magnetic mounting systems were compared with a conventional screw-on system. Six systems on 3 semiadjustable articulators were evaluated: Denar Mark II with conventional screw-on mounting plates (DENSCR) and magnetic mounting system with converter plates (DENCON); Denar Mark 330 with in-built magnetic mounting system (DENMAG) and disposable mounting plates; and Artex CP with blue (ARTBLU), white (ARTWHI), and black (ARTBLA) magnetic mounting plates. Test casts with 3 high-precision ceramic ball bearings at the mandibular central incisor (Point I) and the right and left second molar (Point R; Point L) positions were mounted on 5 mounting plates (n=5) for all 6 systems. Each cast was repositioned 10 times by 4 operators in random order. Nine linear (Ix, Iy, Iz; Rx, Ry, Rz; Lx, Ly, Lz) and 3 angular (anteroposterior, mediolateral, twisting) displacements were measured with a coordinate measuring machine. The mean standard deviations of the linear and angular displacements defined repositioning accuracy. Anteroposterior linear repositioning accuracy ranged from 23.8 ±3.7 μm (DENCON) to 4.9 ±3.2 μm (DENSCR). Mediolateral linear repositioning accuracy ranged from 46.0 ±8.0 μm (DENCON) to 3.7 ±1.5 μm (ARTBLU), and vertical linear repositioning accuracy ranged from 7.2 ±9.6 μm (DENMAG) to 1.5 ±0.9 μm (ARTBLU). Anteroposterior angular repositioning accuracy ranged from 0.0084 ±0.0080 degrees (DENCON) to 0.0020 ±0.0006 degrees (ARTBLU), and mediolateral angular repositioning accuracy ranged from 0.0120 ±0.0111 degrees (ARTWHI) to 0.0027 ±0.0008 degrees (ARTBLU). Twisting angular repositioning accuracy ranged from 0.0419 ±0.0176 degrees (DENCON) to 0.0042 ±0.0038 degrees (ARTBLA). One-way ANOVA found significant differences (P<.05) among all systems for Iy, Ry, Lx, Ly, and twisting. Generally, vertical linear displacements were less likely to reach the threshold of clinical detectability compared with anteroposterior or mediolateral linear displacements. The overall repositioning accuracy of DENSCR was comparable with 4 magnetic mounting systems (DENMAG, ARTBLU, ARTWHI, ARTBLA). DENCON exhibited the worst repositioning accuracy for Iy, Ry, Lx, Ly, and twisting. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Angular-Rate Estimation Using Star Tracker Measurements

    NASA Technical Reports Server (NTRS)

    Azor, R.; Bar-Itzhack, I.; Deutschmann, Julie K.; Harman, Richard R.

    1999-01-01

    This paper presents algorithms for estimating the angular-rate vector of satellites using quaternion measurements. Two approaches are compared, one that uses differentiated quatemion measurements to yield coarse rate measurements which are then fed into two different estimators. In the other approach the raw quatemion measurements themselves are fed directly into the two estimators. The two estimators rely on the ability to decompose the non-linear rate dependent part of the rotational dynamics equation of a rigid body into a product of an angular-rate dependent matrix and the angular-rate vector itself This decomposition, which is not unique, enables the treatment of the nonlinear spacecraft dynamics model as a linear one and, consequently, the application of a Pseudo-Linear Kalman Filter (PSELIKA). It also enables the application of a special Kalman filter which is based on the use of the solution of the State Dependent Algebraic Riccati Equation (SDARE) in order to compute the Kalman gain matrix and thus eliminates the need to propagate and update the filter covariance matrix. The replacement of the elaborate rotational dynamics by a simple first order Markov model is also examined. In this paper a special consideration is given to the problem of delayed quatemion measurements. Two solutions to this problem are suggested and tested. Real Rossi X-Ray Timing Explorer (RXTE) data is used to test these algorithms, and results of these tests are presented.

  4. Angular-Rate Estimation using Star Tracker Measurements

    NASA Technical Reports Server (NTRS)

    Azor, R.; Bar-Itzhack, Itzhack Y.; Deutschmann, Julie K.; Harman, Richard R.

    1999-01-01

    This paper presents algorithms for estimating the angular-rate vector of satellites using quaternion measurements. Two approaches are compared, one that uses differentiated quaternion measurements to yield coarse rate measurements which are then fed into two different estimators. In the other approach the raw quaternion measurements themselves are fed directly into the two estimators. The two estimators rely on the ability to decompose the non-linear rate dependent part of the rotational dynamics equation of a rigid body into a product of an angular-rate dependent matrix and the angular-rate vector itself. This decomposition, which is not unique, enables the treatment of the nonlinear spacecraft dynamics model as a linear one and, consequently, the application of a Pseudo-Linear Kalman Filter (PSELIKA). It also enables the application of a special Kalman filter which is based on the use of the solution of the State Dependent Algebraic Riccati Equation (SDARE) in order to compute the Kalman gain matrix and thus eliminates the need to propagate and update the filter covariance matrix. The replacement of the elaborate rotational dynamics by a simple first order Markov model is also examined. In this paper a special consideration is given to the problem of delayed quaternion measurements. Two solutions to this problem are suggested and tested. Real Rossi X-Ray Timing Explorer (RXTE) data is used to test these algorithms, and results of these tests are presented.

  5. Response of an Impact Test Apparatus for Fall Protective Headgear Testing Using a Hybrid-III Head/Neck Assembly

    PubMed Central

    Caccese, V.; Ferguson, J.; Lloyd, J.; Edgecomb, M.; Seidi, M.; Hajiaghamemar, M.

    2017-01-01

    A test method based upon a Hybrid-III head and neck assembly that includes measurement of both linear and angular acceleration is investigated for potential use in impact testing of protective headgear. The test apparatus is based upon a twin wire drop test system modified with the head/neck assembly and associated flyarm components. This study represents a preliminary assessment of the test apparatus for use in the development of protective headgear designed to prevent injury due to falls. By including angular acceleration in the test protocol it becomes possible to assess and intentionally reduce this component of acceleration. Comparisons of standard and reduced durometer necks, various anvils, front, rear, and side drop orientations, and response data on performance of the apparatus are provided. Injury measures summarized for an unprotected drop include maximum linear and angular acceleration, head injury criteria (HIC), rotational injury criteria (RIC), and power rotational head injury criteria (PRHIC). Coefficient of variation for multiple drops ranged from 0.4 to 6.7% for linear acceleration. Angular acceleration recorded in a side drop orientation resulted in highest coefficient of variation of 16.3%. The drop test apparatus results in a reasonably repeatable test method that has potential to be used in studies of headgear designed to reduce head impact injury. PMID:28216804

  6. Perceptual scale expansion: an efficient angular coding strategy for locomotor space.

    PubMed

    Durgin, Frank H; Li, Zhi

    2011-08-01

    Whereas most sensory information is coded on a logarithmic scale, linear expansion of a limited range may provide a more efficient coding for the angular variables important to precise motor control. In four experiments, we show that the perceived declination of gaze, like the perceived orientation of surfaces, is coded on a distorted scale. The distortion seems to arise from a nearly linear expansion of the angular range close to horizontal/straight ahead and is evident in explicit verbal and nonverbal measures (Experiments 1 and 2), as well as in implicit measures of perceived gaze direction (Experiment 4). The theory is advanced that this scale expansion (by a factor of about 1.5) may serve a functional goal of coding efficiency for angular perceptual variables. The scale expansion of perceived gaze declination is accompanied by a corresponding expansion of perceived optical slants in the same range (Experiments 3 and 4). These dual distortions can account for the explicit misperception of distance typically obtained by direct report and exocentric matching, while allowing for accurate spatial action to be understood as the result of calibration.

  7. Inverse Faraday Effect Revisited

    NASA Astrophysics Data System (ADS)

    Mendonça, J. T.; Ali, S.; Davies, J. R.

    2010-11-01

    The inverse Faraday effect is usually associated with circularly polarized laser beams. However, it was recently shown that it can also occur for linearly polarized radiation [1]. The quasi-static axial magnetic field by a laser beam propagating in plasma can be calculated by considering both the spin and the orbital angular momenta of the laser pulse. A net spin is present when the radiation is circularly polarized and a net orbital angular momentum is present if there is any deviation from perfect rotational symmetry. This orbital angular momentum has recently been discussed in the plasma context [2], and can give an additional contribution to the axial magnetic field, thus enhancing or reducing the inverse Faraday effect. As a result, this effect that is usually attributed to circular polarization can also be excited by linearly polarized radiation, if the incident laser propagates in a Laguerre-Gauss mode carrying a finite amount of orbital angular momentum.[4pt] [1] S. ALi, J.R. Davies and J.T. Mendonca, Phys. Rev. Lett., 105, 035001 (2010).[0pt] [2] J. T. Mendonca, B. Thidé, and H. Then, Phys. Rev. Lett. 102, 185005 (2009).

  8. Perceptual Scale Expansion: An Efficient Angular Coding Strategy for Locomotor Space

    PubMed Central

    Durgin, Frank H.; Li, Zhi

    2011-01-01

    Whereas most sensory information is coded in a logarithmic scale, linear expansion of a limited range may provide a more efficient coding for angular variables important to precise motor control. In four experiments it is shown that the perceived declination of gaze, like the perceived orientation of surfaces is coded on a distorted scale. The distortion seems to arise from a nearly linear expansion of the angular range close to horizontal/straight ahead and is evident in explicit verbal and non-verbal measures (Experiments 1 and 2) and in implicit measures of perceived gaze direction (Experiment 4). The theory is advanced that this scale expansion (by a factor of about 1.5) may serve a functional goal of coding efficiency for angular perceptual variables. The scale expansion of perceived gaze declination is accompanied by a corresponding expansion of perceived optical slants in the same range (Experiments 3 and 4). These dual distortions can account for the explicit misperception of distance typically obtained by direct report and exocentric matching while allowing accurate spatial action to be understood as the result of calibration. PMID:21594732

  9. Brownian self-propelled particles on a sphere

    NASA Astrophysics Data System (ADS)

    Apaza-Pilco, Leonardo Felix; Sandoval, Mario

    We present the dynamics of a Brownian self-propelled particle at low Reynolds number moving on the surface of a sphere. The effects of curvature and self-propulsion on the diffusion of the particle are elucidated by determining (numerically) the mean-square displacement of the particle's angular (azimuthal and polar) coordinates. The results show that the long time behavior of its angular mean-square displacement is linear in time. We also see that the slope of the angular MSD is proportional to the propulsion velocity and inverse to the curvature of the sphere. The angular probability distribution function (PDF) of the particle is also obtained by numerically solving its respective Smoluchowski equation.

  10. Modeling and Analysis of Micro-Spacecraft Attitude Sensing with Gyrowheel.

    PubMed

    Liu, Xiaokun; Zhao, Hui; Yao, Yu; He, Fenghua

    2016-08-19

    This paper proposes two kinds of approaches of angular rate sensing for micro-spacecraft with a gyrowheel (GW), which can combine attitude sensing with attitude control into one single device to achieve a compact micro-spacecraft design. In this implementation, during the three-dimensional attitude control torques being produced, two-dimensional spacecraft angular rates can be sensed from the signals of the GW sensors, such as the currents of the torque coils, the tilt angles of the rotor, the motor rotation, etc. This paper focuses on the problems of the angular rate sensing with the GW at large tilt angles of the rotor. For this purpose, a novel real-time linearization approach based on Lyapunov's linearization theory is proposed, and a GW linearized measurement model at arbitrary tilt angles of the rotor is derived. Furthermore, by representing the two-dimensional rotor tilt angles and tilt control torques as complex quantities and separating the twice periodic terms about the motor spin speed, the linearized measurement model at smaller tilt angles of the rotor is given and simplified. According to the respective characteristics, the application schemes of the two measurement models are analyzed from the engineering perspective. Finally, the simulation results are presented to demonstrate the effectiveness of the proposed strategy.

  11. Modeling and Analysis of Micro-Spacecraft Attitude Sensing with Gyrowheel

    PubMed Central

    Liu, Xiaokun; Zhao, Hui; Yao, Yu; He, Fenghua

    2016-01-01

    This paper proposes two kinds of approaches of angular rate sensing for micro-spacecraft with a gyrowheel (GW), which can combine attitude sensing with attitude control into one single device to achieve a compact micro-spacecraft design. In this implementation, during the three-dimensional attitude control torques being produced, two-dimensional spacecraft angular rates can be sensed from the signals of the GW sensors, such as the currents of the torque coils, the tilt angles of the rotor, the motor rotation, etc. This paper focuses on the problems of the angular rate sensing with the GW at large tilt angles of the rotor. For this purpose, a novel real-time linearization approach based on Lyapunov’s linearization theory is proposed, and a GW linearized measurement model at arbitrary tilt angles of the rotor is derived. Furthermore, by representing the two-dimensional rotor tilt angles and tilt control torques as complex quantities and separating the twice periodic terms about the motor spin speed, the linearized measurement model at smaller tilt angles of the rotor is given and simplified. According to the respective characteristics, the application schemes of the two measurement models are analyzed from the engineering perspective. Finally, the simulation results are presented to demonstrate the effectiveness of the proposed strategy. PMID:27548178

  12. Effects of Pedal Speed and Crank Length on Pedaling Mechanics during Submaximal Cycling.

    PubMed

    Barratt, Paul Richard; Martin, James C; Elmer, Steve J; Korff, Thomas

    2016-04-01

    During submaximal cycling, the neuromuscular system has the freedom to select different intermuscular coordination strategies. From both a basic science and an applied perspective, it is important to understand how the central nervous system adjusts pedaling mechanics in response to changes in pedaling conditions. To determine the effect of changes in pedal speed (a marker of muscle shortening velocity) and crank length (a marker of muscle length) on pedaling mechanics during submaximal cycling. Fifteen trained cyclists performed submaximal isokinetic cycling trials (90 rpm, 240 W) using pedal speeds of 1.41 to 1.61 m·s(-1) and crank lengths of 150 to 190 mm. Joint powers were calculated using inverse dynamics. Increases in pedal speed and crank length caused large increases knee and hip angular excursions and velocities (P < 0.05), whereas ankle angular kinematics stayed relatively constant (P > 0.05). Joint moments and joint powers were less affected by changes in the independent variables, but some interesting effects and trends were observed. Most noteworthy, knee extension moments and powers tended to decrease, whereas hip extension power tended to increase with an increase in crank length. The distribution of joint moments and powers is largely maintained across a range of pedaling conditions. The crank length induced differences in knee extension moments, and powers may represent a trade-off between the central nervous system's attempts to simultaneously minimize muscle metabolic and mechanical stresses. These results increase our understanding of the neural and mechanical mechanisms underlying multi-joint task performance, and they have practical relevance to coaches, athletes, and clinicians.

  13. Effects of ultrashort laser pulses on angular distributions of photoionization spectra.

    PubMed

    Ooi, C H Raymond; Ho, W L; Bandrauk, A D

    2017-07-27

    We study the photoelectron spectra by intense laser pulses with arbitrary time dependence and phase within the Keldysh framework. An efficient semianalytical approach using analytical transition matrix elements for hydrogenic atoms in any initial state enables efficient and accurate computation of the photoionization probability at any observation point without saddle point approximation, providing comprehensive three dimensional photoelectron angular distribution for linear and elliptical polarizations, that reveal the intricate features and provide insights on the photoionization characteristics such as angular dispersions, shift and splitting of photoelectron peaks from the tunneling or above threshold ionization(ATI) regime to non-adiabatic(intermediate) and multiphoton ionization(MPI) regimes. This facilitates the study of the effects of various laser pulse parameters on the photoelectron spectra and their angular distributions. The photoelectron peaks occur at multiples of 2ħω for linear polarization while  odd-ordered peaks are suppressed in the direction perpendicular to the electric field. Short pulses create splitting and angular dispersion where the peaks are strongly correlated to the angles. For MPI and elliptical polarization with shorter pulses the peaks split into doublets and the first peak vanishes. The carrier envelope phase(CEP) significantly affects the ATI spectra while the Stark effect shifts the spectra of intermediate regime to higher energies due to interference.

  14. The Effect of Eight Weeks Plyometric Training on Anaerobic Power, Counter Movement Jumping and Isokinetic Strength in 15-18 Years Basketball Players

    ERIC Educational Resources Information Center

    Adigüzel, Niyazi Sidki; Günay, Mehmet

    2016-01-01

    The purpose of this study was to investigate the effect of eight weeks plyometric training on anaerobic power, counter movement jumping and isokinetic strength in 15-18 years aged basketball players. This study was including 30 male Basketball players. The subjects were divided into two groups as: the experimental group (n = 15) and the control…

  15. [Results of shoulder isokinetic testing in volleyball players].

    PubMed

    Michael, J; König, D; Hessling, U; Popken, F; Eysel, P

    2003-06-01

    Isokinetic testing of the shoulder joint shows valuable indication to possible functional disorders and muscle imbalance. Concentric testing of several parameters using the Cybex 6000 practice unit was done by professional volleyball players performing external and internal rotation of the dominant and non-dominant shoulder at speeds of 60 degrees/s an 180 degrees/s. Sex-specific significant differences were shown which are comparable to other kind of sports.

  16. Short-term effects of kinesio tape on joint position sense, isokinetic measurements, and clinical parameters in patellofemoral pain syndrome

    PubMed Central

    Kurt, Emine Eda; Büyükturan, Öznur; Erdem, Hatice Rana; Tuncay, Figen; Sezgin, Hicabi

    2016-01-01

    [Purpose] To evaluate the short-term effects of kinesio tape on joint position sense, isokinetic measurements, kinesiophobia, symptoms, and functional limitations in patients with patellofemoral pain syndrome. [Subjects and Methods] A total of 90 patients (112 knees) with patellofemoral pain syndrome were randomized into a kinesio tape group (n=45) or placebo kinesio tape group (n=45). Baseline isokinetic quadriceps muscle tests and measurements of joint position sense were performed in both groups. Pain was measured with a Visual Analog Scale, kinesiophobia with the Tampa kinesiophobia scale, and symptoms and functional limitations with the Kujala pain scale. Measurements were repeated 2 days after kinesio tape application. [Results] No differences were found between baseline isokinetic muscle measurements and those taken 2 days after application. However, significant improvements were observed in the kinesio tape group, with regard to joint position sense, pain, kinesiophobia, symptoms, and functional limitations after treatment. Examination of the differences between pre- and post-treatment values in both groups revealed that the kinesio tape group demonstrated greater improvements compared to the placebo kinesio tape group. [Conclusion] Although short-term kinesio tape application did not increase hamstring muscle strength, it may have improved joint position sense, pain, kinesiophobia, symptoms, and daily limitations. PMID:27512259

  17. Neuromuscular and muscle-tendon system adaptations to isotonic and isokinetic eccentric exercise.

    PubMed

    Guilhem, G; Cornu, C; Guével, A

    2010-06-01

    To present the properties of an eccentric contraction and compare neuromuscular and muscle-tendon system adaptations induced by isotonic and isokinetic eccentric trainings. An eccentric muscle contraction is characterized by the production of muscle force associated to a lengthening of the muscle-tendon system. This muscle solicitation can cause micro lesions followed by a regeneration process of the muscle-tendon system. Eccentric exercise is commonly used in functional rehabilitation for its positive effect on collagen synthesis but also for resistance training to increase muscle strength and muscle mass in athletes. Indeed, eccentric training stimulates muscle hypertrophy, increases the fascicle pennation angle, fascicles length and neural activation, thus inducing greater strength gains than concentric or isometric training programs. Eccentric exercise is commonly performed either against a constant external load (isotonic) or at constant velocity (isokinetic), inducing different mechanical constraints. These different mechanical constraints could induce structural and neural adaptive strategies specific to each type of exercise. The literature tends to show that isotonic mode leads to a greater strength gain than isokinetic mode. This observation could be explained by a greater neuromuscular activation after IT training. However, the specific muscle adaptations induced by each mode remain difficult to determine due to the lack of standardized, comparative studies. 2010 Elsevier Masson SAS. All rights reserved.

  18. The isokinetic rotator cuff strength ratios in overhead athletes: Assessment and exercise effect.

    PubMed

    Berckmans, Kelly; Maenhout, Annelies G; Matthijs, Lien; Pieters, Louise; Castelein, Birgit; Cools, Ann M

    2017-09-01

    Muscle strength imbalance in the shoulder region can be considered as a predisposing factor in the development of movement dysfunctions, possibly leading to overuse injuries. Repetitive overhead throwing, performed in sports, may result in muscle imbalance between the external (ER) and internal (IR) rotators. Muscle strength measured with an isokinetic device, is reported as a concentric (CON) or eccentric (ECC) force. The balance between an agonist and an antagonist is mentioned as a ratio (CON/CON or ECC/CON). The aim of this systematic literature review is to provide an overview of the existing evidence considering the isokinetic muscle strength ratios of ER and IR of the shoulder in healthy overhead athletes. In addition, the effect of exercise programs on these ratios was investigated. Two online databases (Web of Science and PubMed) were consulted using different search strategies. Articles were selected based on inclusion and exclusion criteria. All included articles were assessed on their methodological quality. There is moderate evidence for a lower functional deceleration ratio (ECC ER/CON IR) at the dominant side. This lower ratio is due to a large overweight of CON IR strength on that side. There is no consensus about which exercise program is the most effective in altering the shoulder isokinetic strength ratios. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Isokinetic analysis of ankle and ground reaction forces in runners and triathletes

    PubMed Central

    Luna, Natália Mariana Silva; Alonso, Angelica Castilho; Brech, Guilherme Carlos; Mochizuki, Luis; Nakano, Eduardo Yoshio; Greve, Júlia Maria D'Andréa

    2012-01-01

    OBJECTIVE: To analyze and compare the vertical component of ground reaction forces and isokinetic muscle parameters for plantar flexion and dorsiflexion of the ankle between long-distance runners, triathletes, and non-athletes. METHODS: Seventy-five males with a mean age of 30.26 (±6.5) years were divided into three groups: a triathlete group (n = 26), a long-distance runner group (n = 23), and a non-athlete control group. The kinetic parameters were measured during running using a force platform, and the isokinetic parameters were measured using an isokinetic dynamometer. RESULTS: The non-athlete control group and the triathlete group exhibited smaller vertical forces, a greater ground contact time, and a greater application of force during maximum vertical acceleration than the long-distance runner group. The total work (180°/s) was greater in eccentric dorsiflexion and concentric plantar flexion for the non-athlete control group and the triathlete group than the long-distance runner group. The peak torque (60°/s) was greater in eccentric plantar flexion and concentric dorsiflexion for the control group than the athlete groups. CONCLUSIONS: The athlete groups exhibited less muscle strength and resistance than the control group, and the triathletes exhibited less impact and better endurance performance than the runners. PMID:23018298

  20. Comparison of whole-body vibration exercise and plyometric exercise to improve isokinetic muscular strength, jumping performance and balance of female volleyball players

    PubMed Central

    Kim, Yong-Youn; Park, Si-Eun

    2016-01-01

    [Purpose] The purpose of this study was to assess the effect of whole-body vibration exercise and plyometric exercise on female volleyball players. [Subjects and Methods] Subjects were randomly allocated to two exercise groups (whole-body vibration exercise group and plyometric exercise group). The exercise was conducted three times each week for 8 weeks. Isokinetic muscular strength, jumping performance, and balance were measured before starting the exercise and after finishing the 8 weeks of exercise. [Results] Measurements of isokinetic muscular strength revealed that the whole-body vibration exercise group showed significant increase after the exercise. However, the plyometric exercise group had no significant increase in lumbar flexion, extension, and knee flexion. Measurements of vertical jumping revealed that, the whole-body vibration exercise group had no significant increase after the exercise. However, the plyometric exercise group showed significant increase. Measurements of balance revealed that, the whole-body vibration exercise group showed significant increase. However, the plyometric exercise group showed no significant increase. [Conclusion] Although both whole-body vibration and plyometric exercises are effective intervention methods, the two methods have different effects on the improvement of isokinetic muscular strength, jumping performance, and balance of female volleyball players. PMID:27942136

  1. Comparison of whole-body vibration exercise and plyometric exercise to improve isokinetic muscular strength, jumping performance and balance of female volleyball players.

    PubMed

    Kim, Yong-Youn; Park, Si-Eun

    2016-11-01

    [Purpose] The purpose of this study was to assess the effect of whole-body vibration exercise and plyometric exercise on female volleyball players. [Subjects and Methods] Subjects were randomly allocated to two exercise groups (whole-body vibration exercise group and plyometric exercise group). The exercise was conducted three times each week for 8 weeks. Isokinetic muscular strength, jumping performance, and balance were measured before starting the exercise and after finishing the 8 weeks of exercise. [Results] Measurements of isokinetic muscular strength revealed that the whole-body vibration exercise group showed significant increase after the exercise. However, the plyometric exercise group had no significant increase in lumbar flexion, extension, and knee flexion. Measurements of vertical jumping revealed that, the whole-body vibration exercise group had no significant increase after the exercise. However, the plyometric exercise group showed significant increase. Measurements of balance revealed that, the whole-body vibration exercise group showed significant increase. However, the plyometric exercise group showed no significant increase. [Conclusion] Although both whole-body vibration and plyometric exercises are effective intervention methods, the two methods have different effects on the improvement of isokinetic muscular strength, jumping performance, and balance of female volleyball players.

  2. Effects of lower extremity injuries on aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function in high school soccer players.

    PubMed

    Ko, Kwang-Jun; Ha, Gi-Chul; Kim, Dong-Woo; Kang, Seol-Jung

    2017-10-01

    [Purpose] The study investigated the effects of lower extremity injuries on aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function in high school soccer players. [Subjects and Methods] The study assessed U High School soccer players (n=40) in S area, South Korea, divided into 2 groups: a lower extremity injury group (n=16) comprising those with knee and ankle injuries and a control group (n=24) without injury. Aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function were compared and analyzed. [Results] Regarding the aerobic exercise capacity test, significant differences were observed in maximal oxygen uptake and anaerobic threshold between both groups. For the anaerobic power test, no significant difference was observed in peak power and average power between the groups; however, a significant difference in fatigue index was noted. Regarding the knee isokinetic muscular test, no significant difference was noted in knee flexion, extension, and flexion/extension ratio between both groups. [Conclusion] Lower extremity injury was associated with reduced aerobic exercise capacity and a higher fatigue index with respect to anaerobic exercise capacity. Therefore, it seems necessary to establish post-injury training programs that improve aerobic and anaerobic exercise capacity for soccer players who experience lower extremity injury.

  3. Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

    NASA Technical Reports Server (NTRS)

    Ronald, Ross G., Jr.; Johnson, D. L.

    2003-01-01

    This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

  4. The photon gas formulation of thermal radiation

    NASA Technical Reports Server (NTRS)

    Ried, R. C., Jr.

    1975-01-01

    A statistical consideration of the energy, the linear momentum, and the angular momentum of the photons that make up a thermal radiation field was presented. A general nonequilibrium statistical thermodynamics approach toward a macroscopic description of thermal radiation transport was developed and then applied to the restricted equilibrium statistical thermostatics derivation of the energy, linear momentum, and intrinsic angular momentum equations for an isotropic photon gas. A brief treatment of a nonisotropic photon gas, as an example of the results produced by the nonequilibrium statistical thermodynamics approach, was given. The relativistic variation of temperature and the invariance of entropy were illustrated.

  5. Relativistic properties of a molecule: energy, linear momentum, angular momentum and boost momentum to order 1/c 2

    NASA Astrophysics Data System (ADS)

    Cameron, Robert P.; Cotter, J. P.

    2018-05-01

    We give an explicit and general description of the energy, linear momentum, angular momentum and boost momentum of a molecule to order 1/c 2, where it necessary to take account of kinetic contributions made by the electrons and nuclei as well as electromagnetic contributions made by the intramolecular field. A wealth of interesting subtleties are encountered that are not seen at order 1/c 0, including relativistic Hall shifts, anomalous velocities and hidden momenta. Some of these have well known analogues in solid state physics.

  6. Compensation effects and relation between the activation energy of spin transition and the hysteresis loop width for an iron(ii) complex.

    PubMed

    Bushuev, Mark B; Pishchur, Denis P; Nikolaenkova, Elena B; Krivopalov, Viktor P

    2016-06-22

    The enthalpy-entropy compensation was observed for the cooperative → spin transition (the phase is a mononuclear complex [FeL2](BF4)2, L is 4-(3,5-dimethyl-1H-pyrazol-1-yl)-2-(pyridin-2-yl)-6-methylpyrimidine). The physical origin of this effect is the fact that the → spin transition is the first order phase transition accompanied by noticeable variations in the Tonset↑, ΔH and ΔS values. Higher ΔH and ΔS values are correlated with higher Tonset↑ values. The higher the enthalpy and entropy of the spin transition, the wider the hysteresis loop. The kinetic compensation effect, i.e. a linear relationship between ln A and Ea, was observed for the → spin transition. Moreover, an isokinetic relationship was detected in this system: the Arrhenius lines (ln k vs. 1/T) obtained from magnetochemical data for different samples of the phase undergoing the → transition show a common point of intersection (Tiso = 490 ± 2 K, ln kiso = -6.0 ± 0.2). The validity of this conclusion was confirmed by the Exner-Linert statistical method. This means that the isokinetic relationship and the kinetic compensation effect (ln A vs. Ea) in this system are true ones. The existence of a true kinetic compensation effect is supported independently by the fact that the hysteresis loop width for the cooperative spin transition ↔ increases with increasing activation barrier height. Estimating the energy of excitations for the phase with Tiso ∼ 490 K yields wavenumbers of ca. 340 cm(-1) corresponding to the frequencies of the stretching vibrations of the Fe(LS)-N bonds, i.e. the bonds directly involved in the mechanism of the spin transition. This is the first observation of the kinetic compensation effect (ln A vs. Ea) and the isokinetic relationship for a cooperative spin crossover system showing thermal hysteresis. Our results provide the first experimental evidence that the higher the activation barrier for the spin transition, the wider the hysteresis loop for a series of related spin crossover systems.

  7. The Effect of Nasoalveolar Molding on Nasal Airway Anatomy: A 9-Year Follow-up of Patients With Unilateral Cleft Lip and Palate.

    PubMed

    Massie, Jonathan P; Bruckman, Karl; Rifkin, William J; Runyan, Christopher M; Shetye, Pradip R; Grayson, Barry; Flores, Roberto L

    2018-04-01

    To determine the effects of nasoalveolar molding (NAM) on nasal airway architecture. Retrospective case-control study of patients with unilateral cleft lip treated with NAM vs without NAM. Tertiary referral center specializing in cleft and craniofacial care. Patients, Participants, and Interventions: Thirty-six patients with complete unilateral cleft lip and alveolus: 19 with NAM therapy and 17 without NAM therapy. Cone beam computed tomography (CBCT) scans were compared in multiple coronal sections and were evaluated for linear and angular septal deviation, inferior turbinate hypertrophy, and linear and 2-dimensional airway area. There were no significant differences in linear or angular septal deviation, inferior turbinate area, linear stenosis, or airway area between NAM- and non-NAM-treated patients. NAM effectively molds the external nasal cartilage and structures but may have limited effects on internal nasal structures.

  8. A novel upwind stabilized discontinuous finite element angular framework for deterministic dose calculations in magnetic fields.

    PubMed

    Yang, R; Zelyak, O; Fallone, B G; St-Aubin, J

    2018-01-30

    Angular discretization impacts nearly every aspect of a deterministic solution to the linear Boltzmann transport equation, especially in the presence of magnetic fields, as modeled by a streaming operator in angle. In this work a novel stabilization treatment of the magnetic field term is developed for an angular finite element discretization on the unit sphere, specifically involving piecewise partitioning of path integrals along curved element edges into uninterrupted segments of incoming and outgoing flux, with outgoing components updated iteratively. Correct order-of-accuracy for this angular framework is verified using the method of manufactured solutions for linear, quadratic, and cubic basis functions in angle. Higher order basis functions were found to reduce the error especially in strong magnetic fields and low density media. We combine an angular finite element mesh respecting octant boundaries on the unit sphere to spatial Cartesian voxel elements to guarantee an unambiguous transport sweep ordering in space. Accuracy for a dosimetrically challenging scenario involving bone and air in the presence of a 1.5 T parallel magnetic field is validated against the Monte Carlo package GEANT4. Accuracy and relative computational efficiency were investigated for various angular discretization parameters. 32 angular elements with quadratic basis functions yielded a reasonable compromise, with gamma passing rates of 99.96% (96.22%) for a 2%/2 mm (1%/1 mm) criterion. A rotational transformation of the spatial calculation geometry is performed to orient an arbitrary magnetic field vector to be along the z-axis, a requirement for a constant azimuthal angular sweep ordering. Working on the unit sphere, we apply the same rotational transformation to the angular domain to align its octants with the rotated Cartesian mesh. Simulating an oblique 1.5 T magnetic field against GEANT4 yielded gamma passing rates of 99.42% (95.45%) for a 2%/2 mm (1%/1 mm) criterion.

  9. A novel upwind stabilized discontinuous finite element angular framework for deterministic dose calculations in magnetic fields

    NASA Astrophysics Data System (ADS)

    Yang, R.; Zelyak, O.; Fallone, B. G.; St-Aubin, J.

    2018-02-01

    Angular discretization impacts nearly every aspect of a deterministic solution to the linear Boltzmann transport equation, especially in the presence of magnetic fields, as modeled by a streaming operator in angle. In this work a novel stabilization treatment of the magnetic field term is developed for an angular finite element discretization on the unit sphere, specifically involving piecewise partitioning of path integrals along curved element edges into uninterrupted segments of incoming and outgoing flux, with outgoing components updated iteratively. Correct order-of-accuracy for this angular framework is verified using the method of manufactured solutions for linear, quadratic, and cubic basis functions in angle. Higher order basis functions were found to reduce the error especially in strong magnetic fields and low density media. We combine an angular finite element mesh respecting octant boundaries on the unit sphere to spatial Cartesian voxel elements to guarantee an unambiguous transport sweep ordering in space. Accuracy for a dosimetrically challenging scenario involving bone and air in the presence of a 1.5 T parallel magnetic field is validated against the Monte Carlo package GEANT4. Accuracy and relative computational efficiency were investigated for various angular discretization parameters. 32 angular elements with quadratic basis functions yielded a reasonable compromise, with gamma passing rates of 99.96% (96.22%) for a 2%/2 mm (1%/1 mm) criterion. A rotational transformation of the spatial calculation geometry is performed to orient an arbitrary magnetic field vector to be along the z-axis, a requirement for a constant azimuthal angular sweep ordering. Working on the unit sphere, we apply the same rotational transformation to the angular domain to align its octants with the rotated Cartesian mesh. Simulating an oblique 1.5 T magnetic field against GEANT4 yielded gamma passing rates of 99.42% (95.45%) for a 2%/2 mm (1%/1 mm) criterion.

  10. The Angular Three-Point Correlation Function in the Quasi-linear Regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buchalter, Ari; Kamionkowski, Marc; Jaffe, Andrew H.

    2000-02-10

    We calculate the normalized angular three-point correlation function (3PCF), q, as well as the normalized angular skewness, s{sub 3}, assuming the small-angle approximation, for a biased mass distribution in flat and open cold dark matter (CDM) models with Gaussian initial conditions. The leading-order perturbative results incorporate the explicit dependence on the cosmological parameters, the shape of the CDM transfer function, the linear evolution of the power spectrum, the form of the assumed redshift distribution function, and linear and nonlinear biasing, which may be evolving. Results are presented for different redshift distributions, including that appropriate for the APM Galaxy Survey, asmore » well as for a survey with a mean redshift of z{approx_equal}1 (such as the VLA FIRST Survey). Qualitatively, many of the results found for s{sub 3} and q are similar to those obtained in a related treatment of the spatial skewness and 3PCF, such as a leading-order correction to the standard result for s{sub 3} in the case of nonlinear bias (as defined for unsmoothed density fields), and the sensitivity of the configuration dependence of q to both cosmological and biasing models. We show that since angular correlation functions (CFs) are sensitive to clustering over a range of redshifts, the various evolutionary dependences included in our predictions imply that measurements of q in a deep survey might better discriminate between models with different histories, such as evolving versus nonevolving bias, that can have similar spatial CFs at low redshift. Our calculations employ a derived equation, valid for open, closed, and flat models, to obtain the angular bispectrum from the spatial bispectrum in the small-angle approximation. (c) (c) 2000. The American Astronomical Society.« less

  11. A new approach to three-dimensional neutron transport solution based on the method of characteristics and linear axial approximation

    NASA Astrophysics Data System (ADS)

    Zheng, Youqi; Choi, Sooyoung; Lee, Deokjung

    2017-12-01

    A new approach based on the method of characteristics (MOC) is proposed to solve the neutron transport equation. A new three-dimensional (3D) spatial discretization is applied to avoid the instability issue of the transverse leakage iteration of the traditional 2D/1D approach. In this new approach, the axial and radial variables are discretized in two different ways: the linear expansion is performed in the axial direction, then, the 3D solution of the angular flux is transformed to be the planar solution of 2D angular expansion moments, which are solved by the planar MOC sweeping. Based on the boundary and interface continuity conditions, the 2D expansion moment solution is equivalently transformed to be the solution of the axially averaged angular flux. Using the piecewise averaged angular flux at the top and bottom surfaces of 3D meshes, the planes are coupled to give the 3D angular flux distribution. The 3D CMFD linear system is established from the surface net current of every 3D pin-mesh to accelerate the convergence of power iteration. The STREAM code is extended to be capable of handling 3D problems based on the new approach. Several benchmarks are tested to verify its feasibility and accuracy, including the 3D homogeneous benchmarks and heterogeneous benchmarks. The computational sensitivity is discussed. The results show good accuracy in all tests. With the CMFD acceleration, the convergence is stable. In addition, a pin-cell problem with void gap is calculated. This shows the advantage compared to the traditional 2D/1D MOC methods.

  12. The mass and angular momentum of reconstructed metric perturbations

    NASA Astrophysics Data System (ADS)

    van de Meent, Maarten

    2017-06-01

    We prove a key result regarding the mass and angular momentum content of linear vacuum perturbations of the Kerr metric obtained through the formalism developed by Chrzarnowski, Cohen, and Kegeles (CCK). More precisely, we prove that the Abbott-Deser mass and angular momentum integrals of any such perturbation vanish when that perturbation was obtained from a regular Fourier mode of the Hertz potential. As a corollary we obtain a generalization of previous results on the completion of the ‘no string’ radiation gauge metric perturbation generated by a point particle. We find that for any bound orbit around a Kerr black hole, the mass and angular momentum perturbations completing the CCK metric are simply the energy and angular momentum of the particle ‘outside’ the orbit and vanish ‘inside’ the orbit.

  13. Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer

    NASA Technical Reports Server (NTRS)

    Wickwire, P. J.; Leach, M.; Ryder, J.; Ploutz-Snyder, R.; Ploutz-Snyder, L.

    2011-01-01

    Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training.

  14. The effects of whole-body vibration exercise on isokinetic muscular function of the knee and jump performance depending on squatting position

    PubMed Central

    Kim, Jaeyuong; Park, Yunjin; Seo, Yonggon; Kang, Gyumin; Park, Sangseo; Cho, Hyeyoung; Moon, Hyunghoon; Kim, Myungki; Yu, Jaeho

    2016-01-01

    [Purpose] The purpose of this study was to investigate the effects of whole-body vibration exercise (WBVE) on isokinetic muscular function of the knee and jump performance depending on different squatting positions. [Subjects] The subjects were 12 healthy adult men who did not exercise regularly between the ages of 27 and 34. [Methods] WBVE was performed with high squat position (SP), middle SP, and low SP. Before and after the intervention, isokinetic muscular function of the knees and jump performance were measured. [Results] Knee flexion peak torque at 60°/s and total work at 180°/s were significantly increased after implementing WBVE. Jump height also significantly increased after completing the exercise at all positions in comparison with the pre-exercise programs. [Conclusion] The results of this study suggest that SP during WBVE is an important factor stimulating positive effects on muscular function. PMID:26957749

  15. Comparison of basic physical fitness, aerobic capacity, and isokinetic strength between national and international level high school freestyle swimmers

    PubMed Central

    Bae, Young-Hyeon; Yu, Jae-Ho; Lee, Suk Min

    2016-01-01

    [Purpose] This study aimed to compare basic physical fitness, aerobic capacity, and isokinetic strength between international and national level freestyle high school student swimmers. [Subjects and Methods] A total of 28 participants (14 international level swimmers and 14 national level freestyle high school student swimmers) with no known pathology were included. We used a cross-sectional study to examine three variables: basic physical fitness, aerobic capacity, and isokinetic strength. [Results] The mean values of these variables in the international level swimmers were higher than those in the national level swimmers. Swimmers are generally physically fit with a good competition record. [Conclusion] An appropriate training program, which considers specific individual characteristics is likely to have a positive impact on the improvement of total physical fitness, and subsequently, on the performance of the freestyle high school swimmer. PMID:27134379

  16. Adaptation to vestibular disorientation. IX, Influence of head position on the habituation of vertical nystagmus.

    DOT National Transportation Integrated Search

    1968-03-01

    Interactions of linear and angular accelerations are frequently experienced by pilots during aircraft maneuvers. Several recent studies have indicated that the otoliths (detectors of linear acceleration) may influence responses of the semicircular ca...

  17. Hamstring and Quadriceps Isokinetic Strength Deficits Are Weak Risk Factors for Hamstring Strain Injuries: A 4-Year Cohort Study.

    PubMed

    van Dyk, Nicol; Bahr, Roald; Whiteley, Rodney; Tol, Johannes L; Kumar, Bhavesh D; Hamilton, Bruce; Farooq, Abdulaziz; Witvrouw, Erik

    2016-07-01

    A hamstring strain injury (HSI) has become the most common noncontact injury in soccer. Isokinetic muscle strength deficits are considered a risk factor for HSIs. However, underpowered studies with small sample sizes unable to determine small associations have led to inconclusive results regarding the role of isokinetic strength and strength testing in HSIs. To examine whether differences in isokinetic strength measures of knee flexion and extension represent risk factors for hamstring injuries in a large cohort of professional soccer players in an adequately powered study design. Cohort study; Level of evidence, 2. A total of 614 professional soccer players from 14 teams underwent isokinetic strength testing during preseason screening. Testing consisted of concentric knee flexion and extension at 60 deg/s and 300 deg/s and eccentric knee extension at 60 deg/s. A clustered multiple logistic regression analysis was used to identify variables associated with the risk of HSIs. Receiver operating characteristic (ROC) curves were calculated to determine sensitivity and specificity. Of the 614 players, 190 suffered an HSI during the 4 seasons. Quadriceps concentric strength at 60 deg/s (odds ratio [OR], 1.41; 95% CI, 1.03-1.92; P = .03) and hamstring eccentric strength at 60 deg/s (OR, 1.37; 95% CI, 1.01-1.85; P = .04) adjusted for bodyweight were independently associated with the risk of injuries. The absolute differences between the injured and uninjured players were 6.9 N·m and 9.1 N·m, with small effect sizes (d < 0.2). The ROC analyses showed an area under the curve of 0.54 and 0.56 for quadriceps concentric strength and hamstring eccentric strength, respectively, indicating a failed combined sensitivity and specificity of the 2 strength variables identified in the logistic regression models. This study identified small absolute strength differences and a wide overlap of the absolute strength measurements at the group level. The small associations between lower hamstring eccentric strength and lower quadriceps concentric strength with HSIs can only be considered as weak risk factors. The identification of these risk factors still does not allow the identification of individual players at risk. The use of isokinetic testing to determine the association between strength differences and HSIs is not supported. © 2016 The Author(s).

  18. Proprioceptive isokinetic exercise test

    NASA Technical Reports Server (NTRS)

    Dempster, P. T.; Bernauer, E. M.; Bond, M.; Greenleaf, J. E.

    1993-01-01

    Proprioception, the reception of stimuli within the body that indicates position, is an important mechanism for optimal human performance. People exposed to prolonged bed rest, microgravity, or other deconditioning situations usually experience reduced proprioceptor and kinesthetic stimuli that compromise body balance, posture, and equilibrium. A new proprioceptive test is described that utilizes the computer-driven LIDO isokinetic ergometer. An overview of the computer logic, software, and testing procedure for this proprioceptive test, which can be performed with the arms or legs, is described.

  19. Isokinetic and isometric strength in osteoarthrosis of the knee. A comparative study with healthy women.

    PubMed

    Tan, J; Balci, N; Sepici, V; Gener, F A

    1995-01-01

    Dynamic stability of the knee joint depends on the appropriate strength ratio of quadriceps and hamstring muscles. The purpose of this investigation was to determine the maximum peak torque (MPT) and MPT ratios of hamstrings to quadriceps (H/Q) muscles in patients with knee osteoarthritis (OA). Two groups of patients were included in the study. The first group consisted of 30 patients (Group A) with the clinical and radiologic findings of knee OA. The second group consisted of 30 patients (Group B) exhibiting knee joint pain without roentgenologic findings of knee OA. The findings of two patient groups were compared with each other and also with 30 healthy subjects (Group C). Isokinetic (at 60 degrees/s and at 180 degrees/s) and isometric (at 30 degrees and at 60 degrees of knee flexion) tests were performed by the rate-limiting isokinetic dynamometer system. Isokinetic and isometric MPT loss of knee flexors and extensors was found in both patient groups with respect to controls, but MPT ratios of H/Q muscles did not show a statistically significant difference compared with the control group. This may be related to the equal strength loss of knee flexors and knee extensors in patients with knee OA. It is concluded that strengthening exercises of hamstring muscles is as important as quadriceps strengthening in rehabilitation of knee OA.

  20. Systems and methods for estimating the structure and motion of an object

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dani, Ashwin P; Dixon, Warren

    2015-11-03

    In one embodiment, the structure and motion of a stationary object are determined using two images and a linear velocity and linear acceleration of a camera. In another embodiment, the structure and motion of a stationary or moving object are determined using an image and linear and angular velocities of a camera.

  1. A rough end for smooth microstate geometries

    DOE PAGES

    Marolf, Donald; Michel, Ben; Puhm, Andrea

    2017-05-03

    Supersymmetric microstate geometries with five non-compact dimensions have recently been shown by Eperon, Reall, and Santos (ERS) to exhibit a non-linear instability featuring the growth of excitations at an “evanescent ergosurface” of infinite redshift. We argue that this growth may be treated as adiabatic evolution along a family of exactly supersymmetric solutions in the limit where the excitations are Aichelburg-Sexl-like shockwaves. In the 2-charge system such solutions may be constructed explicitly, incorpo-rating full backreaction, and are in fact special cases of known microstate geometries. In a near-horizon limit, they reduce to Aichelburg-Sexl shockwaves in AdS 3 × S 3 propagatingmore » along one of the angular directions of the sphere. Noting that the ERS analysis is valid in the limit of large microstate angular momentum j, we use the above identification to interpret their instability as a transition from rare smooth microstates with large angular momentum to more typical microstates with smaller angular momentum. This entropic driving terminates when the angular momentum decreases to j~√n 1n 5 where the density of microstates is maximal. Finally, we argue that, at this point, the large stringy corrections to such microstates will render them non-linearly stable. We identify a possible mechanism for this stabilization and detail an illustrative toy model.« less

  2. Theoretical issues on the spontaneous rotation of axisymmetric plasmas

    NASA Astrophysics Data System (ADS)

    Coppi, B.; Zhou, T.

    2014-09-01

    An extensive series of experiments have confirmed that the observed ‘spontaneous rotation’ phenomenon in axisymmetric plasmas is related to the confinement properties of these plasmas and connected to the excitation of collective modes associated with these properties (Coppi 2000 18th IAEA Fusion Energy Conf. (Sorrento, Italy, 2000) THP 1/17, www-pub.iaea.org/MTCD/publications/PDF/csp_008c/html/node343.htm and Coppi 2002 Nucl. Fusion 42 1). In particular, radially localized modes can extract angular momentum from the plasma column from which they grow while the background plasma has to recoil in the direction opposite to that of the mode phase velocity. In the case of the excitation of the plasma modes at the edge, the loss of their angular momentum can be connected to the directed particle ejection to the surrounding medium. The recoil angular momentum is then redistributed inside the plasma column mainly by the combination of an effective viscous diffusion and an inward angular momentum transport velocity that is connected, for instance, to ion temperature gradient (ITG) driven modes. The linear and quasi-linear theories of the collisionless trapped electron modes and of the toroidal ITG driven modes are re-examined in the context of their influence on angular momentum transport. Internal modes that produce magnetic reconnection and are electromagnetic in nature, acquire characteristic phase velocity directions in high temperature regimes and become relevant to the ‘generation’ of angular momentum. The drift-tearing mode, the ‘complex’ reconnecting mode and the m0 = 1 internal mode belong to this category, the last mode acquiring different features depending on the strength of its driving factor. Toroidal velocity profiles that reproduce the experimental observations are obtained considering a global angular momentum balance equation that includes the localized sources associated with the excited internal electrostatic and electromagnetic modes besides the appropriate diffusive and the inward angular momentum transparent terms.

  3. Spectromicroscopy study of interfacial Co/NiO(001)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van der Laan, Gerrit; Telling, Neil; Potenza, Alberto

    2010-09-26

    Photoemission electron microscopy (PEEM) with linearly polarized x-rays is used to determine the orientation of antiferromagnetic domains by monitoring the relative peak intensities at the 3d transition metal L{sub 2} absorption edge. In such an analysis the orientations of the x-ray polarization E and magnetization H with respect to the crystalline axes has to be taken into account. We address this problem by presenting a general expression of the angular dependence for both x-ray absorption spectroscopy and x-ray magnetic linear dichroism (XMLD) for arbitrary direction of E and H in the (001) cubic plane. In cubic symmetry the angular dependentmore » XMLD is a linear combination of two spectra with different photon energy dependence, which reduces to one spectrum when E or H is along a high-symmetry axis. The angular dependent XMLD can be separated into an isotropic term, which is symmetric along H, and an anisotropic term, which depends on the orientation of the crystal axes. The anisotropic term has maximal intensity when E and H have equal but opposite angles with respect to the [100] direction. The Ni{sup 2+} L{sub 2} edge has the peculiarity that the isotropic term vanishes, which means that the maximum in the XMLD intensity is observed not only for E {parallel} H {parallel} [100] but also for (E {parallel} [110], H {parallel} [110]). We apply the angular dependent theory to determine the spin orientation near the Co/NiO(100) interface. The PEEM images show that the ferromagnetic Co moments and antiferromagnetic NiO moments are aligned perpendicular to each other. By rotating the sample with respect to the linear x-ray polarization we furthermore find that the perpendicular coupling with the ferromagnetic Co layer at the interface causes a canting of the antiferromagnetic Ni moments. This shows that taking into account the angular dependence of the XMLD in the detailed analysis of PEEM images leads to an accurate retrieval of the spin axes of the antiferromagnetic domains.« less

  4. Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

    PubMed Central

    Kim, Won Kuel; Seo, Kyung Mook; Kang, Si Hyun

    2014-01-01

    Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength. PMID:24639931

  5. Study on Aerosol Penetration Through Clothing and Individual Protective Equipment

    DTIC Science & Technology

    2009-05-01

    8.4X10-3 mg.m-3 (2.57X105 particles per cubic meter of air) over a 30 minute period. This scenario represents a very high end threat with a large... Isokinetic air sampling was applied and the effect of aerosol losses in sampling lines and other parts of the test rig were incorporated in analysis...eliminate any “memory” effect. The aerosol sampling (airflow direction control, start of sampling) was operated manually. Isokinetic sampling conditions

  6. Demonstrating the conservation of angular momentum using spherical magnets

    NASA Astrophysics Data System (ADS)

    Lindén, Johan; Slotte, Joakim; Källman, Kjell-Mikael

    2018-01-01

    An experimental setup for demonstrating the conservation of angular momentum of rotating spherical magnets is described. Two spherical Nd-Fe-B magnets are placed on a double inclined plane and projected towards each other with pre-selected impact parameters ranging from zero to a few tens of millimeters. After impact, the two magnets either revolve vigorously around the common center of mass or stop immediately, depending on the value of the impact parameter. Using a pick-up coil connected to an oscilloscope, the angular frequency for the rotating magnets was measured, and an estimate for the angular momentum was obtained. A high-speed video camera captured the impact and was used for measuring linear and angular velocities of the magnets. A very good agreement between the initial angular momentum before the impact and the final angular momentum of the revolving dumbbell is observed. The two rotating magnets, and the rotating electromagnetic field emanating from them, can also be viewed as a toy model for the newly discovered gravitational waves, where two black holes collide after revolving around each other. (Enhanced online)

  7. Angular Rate Sensing with GyroWheel Using Genetic Algorithm Optimized Neural Networks.

    PubMed

    Zhao, Yuyu; Zhao, Hui; Huo, Xin; Yao, Yu

    2017-07-22

    GyroWheel is an integrated device that can provide three-axis control torques and two-axis angular rate sensing for small spacecrafts. Large tilt angle of its rotor and de-tuned spin rate lead to a complex and non-linear dynamics as well as difficulties in measuring angular rates. In this paper, the problem of angular rate sensing with the GyroWheel is investigated. Firstly, a simplified rate sensing equation is introduced, and the error characteristics of the method are analyzed. According to the analysis results, a rate sensing principle based on torque balance theory is developed, and a practical way to estimate the angular rates within the whole operating range of GyroWheel is provided by using explicit genetic algorithm optimized neural networks. The angular rates can be determined by the measurable values of the GyroWheel (including tilt angles, spin rate and torque coil currents), the weights and the biases of the neural networks. Finally, the simulation results are presented to illustrate the effectiveness of the proposed angular rate sensing method with GyroWheel.

  8. Forming Disc Galaxies In Major Mergers: Radial Density Profiles And Angular Momentum

    NASA Astrophysics Data System (ADS)

    Peschken, Nicolas; Athanassoula, E.; Rodionov, S. A.; Lambert, J. C.

    2017-06-01

    In Athanassoula et al. (2016), we used high resolution N-body hydrodynamical simulations to model the major merger between two disc galaxies with a hot gaseous halo each, and showed that the remnant is a spiral galaxy. The two discs are destroyed by the collision, but after the merger, accretion from the surrounding gaseous halo allows the building of a new disc in the remnant galaxy. In Peschken et al. (2017), we used these simulations to study the radial surface density profiles of the remnant galaxies with downbending profiles (type II), i.e. composed of an inner and an outer exponential disc separated by a break. We analyzed the effect of angular momentum on these profiles, and found that the inner and outer disc scalelengths, as well as the break radius, all increase linearly with the total angular momentum of the initial merging system. Following the angular momentum redistribution in our simulations, we find that the disc angular momentum is acquired via accretion from the gaseous halo. Furthermore, high angular momentum systems give more angular momentum to their discs, which affects directly their radial density profile.

  9. Factors influencing perceived angular velocity

    NASA Technical Reports Server (NTRS)

    Kaiser, Mary K.; Calderone, Jack B.

    1991-01-01

    Angular velocity perception is examined for rotations both in depth and in the image plane and the influence of several object properties on this motion parameter is explored. Two major object properties are considered, namely, texture density which determines the rate of edge transitions for rotations in depth, i.e., the number of texture elements that pass an object's boundary per unit of time, and object size which determines the tangential linear velocities and 2D image velocities of texture elements for a given angular velocity. Results of experiments show that edge-transition rate biased angular velocity estimates only when edges were highly salient. Element velocities had an impact on perceived angular velocity; this bias was associated with 2D image velocity rather than 3D tangential velocity. Despite these biases judgements were most strongly determined by the true angular velocity. Sensitivity to this higher order motion parameter appeared to be good for rotations both in depth (y-axis) and parallel to the line of sight (z-axis).

  10. Coherent π-electron dynamics of (P)-2,2'-biphenol induced by ultrashort linearly polarized UV pulses: Angular momentum and ring current

    NASA Astrophysics Data System (ADS)

    Mineo, H.; Lin, S. H.; Fujimura, Y.

    2013-02-01

    The results of a theoretical investigation of coherent π-electron dynamics for nonplanar (P)-2,2'-biphenol induced by ultrashort linearly polarized UV pulses are presented. Expressions for the time-dependent coherent angular momentum and ring current are derived by using the density matrix method. The time dependence of these coherences is determined by the off-diagonal density matrix element, which can be obtained by solving the coupled equations of motion of the electronic-state density matrix. Dephasing effects on coherent angular momentum and ring current are taken into account within the Markov approximation. The magnitudes of the electronic angular momentum and current are expressed as the sum of expectation values of the corresponding operators in the two phenol rings (L and R rings). Here, L (R) denotes the phenol ring in the left (right)-hand side of (P)-2,2'-biphenol. We define the bond current between the nearest neighbor carbon atoms Ci and Cj as an electric current through a half plane perpendicular to the Ci-Cj bond. The bond current can be expressed in terms of the inter-atomic bond current. The inter-atomic bond current (bond current) depends on the position of the half plane on the bond and has the maximum value at the center. The coherent ring current in each ring is defined by averaging over the bond currents. Since (P)-2,2'-biphenol is nonplanar, the resultant angular momentum is not one-dimensional. Simulations of the time-dependent coherent angular momentum and ring current of (P)-2,2'-biphenol excited by ultrashort linearly polarized UV pulses are carried out using the molecular parameters obtained by the time-dependent density functional theory (TD-DFT) method. Oscillatory behaviors in the time-dependent angular momentum (ring current), which can be called angular momentum (ring current) quantum beats, are classified by the symmetry of the coherent state, symmetric or antisymmetric. The bond current of the bridge bond linking the L and R rings is zero for the symmetric coherent state, while it is nonzero for the antisymmetric coherent state. The magnitudes of ring current and ring current-induced magnetic field are also evaluated, and their possibility as a control parameter in ultrafast switching devices is discussed. The present results give a detailed description of the theoretical treatment reported in our previous paper [H. Mineo, M. Yamaki, Y. Teranish, M. Hayashi, S. H. Lin, and Y. Fujimura, J. Am. Chem. Soc. 134, 14279 (2012), 10.1021/ja3047848].

  11. Coherent π-electron dynamics of (P)-2,2'-biphenol induced by ultrashort linearly polarized UV pulses: angular momentum and ring current.

    PubMed

    Mineo, H; Lin, S H; Fujimura, Y

    2013-02-21

    The results of a theoretical investigation of coherent π-electron dynamics for nonplanar (P)-2,2'-biphenol induced by ultrashort linearly polarized UV pulses are presented. Expressions for the time-dependent coherent angular momentum and ring current are derived by using the density matrix method. The time dependence of these coherences is determined by the off-diagonal density matrix element, which can be obtained by solving the coupled equations of motion of the electronic-state density matrix. Dephasing effects on coherent angular momentum and ring current are taken into account within the Markov approximation. The magnitudes of the electronic angular momentum and current are expressed as the sum of expectation values of the corresponding operators in the two phenol rings (L and R rings). Here, L (R) denotes the phenol ring in the left (right)-hand side of (P)-2,2'-biphenol. We define the bond current between the nearest neighbor carbon atoms Ci and Cj as an electric current through a half plane perpendicular to the Ci-Cj bond. The bond current can be expressed in terms of the inter-atomic bond current. The inter-atomic bond current (bond current) depends on the position of the half plane on the bond and has the maximum value at the center. The coherent ring current in each ring is defined by averaging over the bond currents. Since (P)-2,2'-biphenol is nonplanar, the resultant angular momentum is not one-dimensional. Simulations of the time-dependent coherent angular momentum and ring current of (P)-2,2'-biphenol excited by ultrashort linearly polarized UV pulses are carried out using the molecular parameters obtained by the time-dependent density functional theory (TD-DFT) method. Oscillatory behaviors in the time-dependent angular momentum (ring current), which can be called angular momentum (ring current) quantum beats, are classified by the symmetry of the coherent state, symmetric or antisymmetric. The bond current of the bridge bond linking the L and R rings is zero for the symmetric coherent state, while it is nonzero for the antisymmetric coherent state. The magnitudes of ring current and ring current-induced magnetic field are also evaluated, and their possibility as a control parameter in ultrafast switching devices is discussed. The present results give a detailed description of the theoretical treatment reported in our previous paper [H. Mineo, M. Yamaki, Y. Teranish, M. Hayashi, S. H. Lin, and Y. Fujimura, J. Am. Chem. Soc. 134, 14279 (2012)].

  12. Sequential two-photon double ionization of noble gases by circularly polarized XUV radiation

    NASA Astrophysics Data System (ADS)

    Gryzlova, E. V.; Grum-Grzhimailo, A. N.; Kuzmina, E. I.; Strakhova, S. I.

    2014-10-01

    Photoelectron angular distributions (PADs) and angular correlations between two emitted electrons in sequential two-photon double ionization (2PDI) of atoms by circularly polarized radiation are studied theoretically. In particular, the sequential 2PDI of the valence n{{p}6} shell in noble gas atoms (neon, argon, krypton) is analyzed, accounting for the first-order corrections to the dipole approximation. Due to different selection rules in ionization transitions, the circular polarization of photons causes some new features of the cross sections, PADs and angular correlation functions in comparison with the case of linearly polarized photons.

  13. The Gaussian Laser Angular Distribution in HYDRA's 3D Laser Ray Trace Package

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sepke, Scott M.

    In this note, the angular distribution of rays launched by the 3D LZR ray trace package is derived for Gaussian beams (npower==2) with bm model=3±. Beams with bm model=+3 have a nearly at distribution, and beams with bm model=-3 have a nearly linear distribution when the spot size is large compared to the wavelength.

  14. Effects of Pedal Speed and Crank Length on Pedaling Mechanics during Submaximal Cycling

    PubMed Central

    BARRATT, PAUL RICHARD; MARTIN, JAMES C.; ELMER, STEVE J.; KORFF, THOMAS

    2016-01-01

    ABSTRACT During submaximal cycling, the neuromuscular system has the freedom to select different intermuscular coordination strategies. From both a basic science and an applied perspective, it is important to understand how the central nervous system adjusts pedaling mechanics in response to changes in pedaling conditions. Purpose To determine the effect of changes in pedal speed (a marker of muscle shortening velocity) and crank length (a marker of muscle length) on pedaling mechanics during submaximal cycling. Methods Fifteen trained cyclists performed submaximal isokinetic cycling trials (90 rpm, 240 W) using pedal speeds of 1.41 to 1.61 m·s−1 and crank lengths of 150 to 190 mm. Joint powers were calculated using inverse dynamics. Results Increases in pedal speed and crank length caused large increases knee and hip angular excursions and velocities (P < 0.05), whereas ankle angular kinematics stayed relatively constant (P > 0.05). Joint moments and joint powers were less affected by changes in the independent variables, but some interesting effects and trends were observed. Most noteworthy, knee extension moments and powers tended to decrease, whereas hip extension power tended to increase with an increase in crank length. Conclusions The distribution of joint moments and powers is largely maintained across a range of pedaling conditions. The crank length induced differences in knee extension moments, and powers may represent a trade-off between the central nervous system’s attempts to simultaneously minimize muscle metabolic and mechanical stresses. These results increase our understanding of the neural and mechanical mechanisms underlying multi-joint task performance, and they have practical relevance to coaches, athletes, and clinicians. PMID:26559455

  15. CCD Measurements of Double and Multiple Stars at NAO Rozhen and ASV in 2015

    NASA Astrophysics Data System (ADS)

    Cvetković, Z.; Pavlović, R.; Boeva, S.

    2017-04-01

    Results of CCD observations of 154 double or multiple stars, made with the 2 m telescope of the Bulgarian National Astronomical Observatory at Rozhen over five nights in 2015, are presented. This is the ninth series of measurements of CCD frames obtained at Rozhen. We also present results of CCD observations of 323 double or multiple stars made with the 0.6 m telescope of the Serbian Astronomical Station on the mountain of Vidojevica over 23 nights in 2015. This is the fourth series of measurements of CCD frames obtained at this station. This paper contains the results for the position angle and angular separation for 801 pairs and residuals for 127 pairs with published orbital elements or linear solutions. The angular separations are in the range from 1.″52 to 201.″56, with a median angular separation of 8.″26. We also present eight pairs that are measured for the first time and linear elements for five pairs.

  16. Soft Ionic Electroactive Polymer Actuators with Tunable Non-Linear Angular Deformation

    PubMed Central

    Hong, Wangyujue; Almomani, Abdallah; Chen, Yuanfen; Jamshidi, Reihaneh; Montazami, Reza

    2017-01-01

    The most rational approach to fabricate soft robotics is the implementation of soft actuators. Conventional soft electromechanical actuators exhibit linear or circular deformation, based on their design. This study presents the use of conjugated polymers, Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) to locally vary ion permeability of the ionic electroactive polymer actuators and manipulate ion motion through means of structural design to realize intrinsic angular deformation. Such angular deformations are closer to biomimetic systems and have potential applications in bio-robotics. Electrochemical studies reveal that the mechanism of actuation is mainly associated with the charging of electric double layer (EDL) capacitors by ion accumulation and the PEDOT:PSS layer’s expansion by ion interchange and penetration. Dependence of actuator deformation on structural design is studied experimentally and conclusions are verified by analytical and finite element method modeling. The results suggest that the ion-material interactions are considerably dominated by the design of the drop-cast PEDOT:PSS on Nafion. PMID:28773036

  17. Soft Ionic Electroactive Polymer Actuators with Tunable Non-Linear Angular Deformation.

    PubMed

    Hong, Wangyujue; Almomani, Abdallah; Chen, Yuanfen; Jamshidi, Reihaneh; Montazami, Reza

    2017-06-21

    The most rational approach to fabricate soft robotics is the implementation of soft actuators. Conventional soft electromechanical actuators exhibit linear or circular deformation, based on their design. This study presents the use of conjugated polymers, Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) to locally vary ion permeability of the ionic electroactive polymer actuators and manipulate ion motion through means of structural design to realize intrinsic angular deformation. Such angular deformations are closer to biomimetic systems and have potential applications in bio-robotics. Electrochemical studies reveal that the mechanism of actuation is mainly associated with the charging of electric double layer (EDL) capacitors by ion accumulation and the PEDOT:PSS layer's expansion by ion interchange and penetration. Dependence of actuator deformation on structural design is studied experimentally and conclusions are verified by analytical and finite element method modeling. The results suggest that the ion-material interactions are considerably dominated by the design of the drop-cast PEDOT:PSS on Nafion.

  18. Spin angular momentum induced by optical quasi-phonons activated in birefringent uniaxial crystals

    NASA Astrophysics Data System (ADS)

    Mohamadou, B.; Maïmounatou, B.; Erasmus, R. M.

    2017-09-01

    The present report formally establishes the expression of the angular momentum of the quasi-phonons induced by linearly polarized light. The transferred mechanical torque due to phonons is then determined from the spin angular momentum and is shown to be measurable from Raman scattering experiments. To investigate this, the electric field due the excited dipoles and the associated macroscopic dielectric polarization vectors were first calculated using a lattice dynamical model in order to derive in a second step the analytical expression of the angular momentum density arising from the inelastic light scattering by quasi-phonons. The numerical results of the calculated angle dependent mode electric fields and the induced spin angular moments as well as the transferred torques were analyzed with regard to some typical behaviors of the interacting modes and it is shown that the fluctuations of the effective charges is their main origin.

  19. Extreme Ultraviolet Fractional Orbital Angular Momentum Beams from High Harmonic Generation

    PubMed Central

    Turpin, Alex; Rego, Laura; Picón, Antonio; San Román, Julio; Hernández-García, Carlos

    2017-01-01

    We investigate theoretically the generation of extreme-ultraviolet (EUV) beams carrying fractional orbital angular momentum. To this end, we drive high-order harmonic generation with infrared conical refraction (CR) beams. We show that the high-order harmonic beams emitted in the EUV/soft x-ray regime preserve the characteristic signatures of the driving beam, namely ringlike transverse intensity profile and CR-like polarization distribution. As a result, through orbital and spin angular momentum conservation, harmonic beams are emitted with fractional orbital angular momentum, and they can be synthesized into structured attosecond helical beams –or “structured attosecond light springs”– with rotating linear polarization along the azimuth. Our proposal overcomes the state of the art limitations for the generation of light beams far from the visible domain carrying non-integer orbital angular momentum and could be applied in fields such as diffraction imaging, EUV lithography, particle trapping, and super-resolution imaging. PMID:28281655

  20. All joint moments significantly contribute to trunk angular acceleration

    PubMed Central

    Nott, Cameron R.; Zajac, Felix E.; Neptune, Richard R.; Kautz, Steven A.

    2010-01-01

    Computationally advanced biomechanical analyses of gait demonstrate the often counter intuitive roles of joint moments on various aspects of gait such as propulsion, swing initiation, and balance. Each joint moment can produce linear and angular acceleration of all body segments (including those on which the moment does not directly act) due to the dynamic coupling inherent in the interconnected musculoskeletal system. This study presents the quantitative relationships between individual joint moments and trunk control with respect to balance during gait to show that the ankle, knee, and hip joint moments all affect the angular acceleration of the trunk. We show that trunk angular acceleration is affected by all the joints in the leg with varying degrees of dependence during the gait cycle. Furthermore, it is shown that inter-planar coupling exists and a two dimensional analysis of trunk balance neglects important out-of-plane joint moments that affect trunk angular acceleration. PMID:20646711

  1. Kinetic energy and angular momentum of free particles in the gyratonic pp-waves space-times

    NASA Astrophysics Data System (ADS)

    Maluf, J. W.; da Rocha-Neto, J. F.; Ulhoa, S. C.; Carneiro, F. L.

    2018-06-01

    Gyratonic pp-waves are exact solutions of Einstein’s equations that represent non-linear gravitational waves endowed with angular momentum. We consider gyratonic pp-waves that travel in the z direction and whose time dependence on the variable is given by Gaussians, so that the waves represent short bursts of gravitational radiation propagating in the z direction. We evaluate numerically the geodesics and velocities of free particles in the space-time of these waves, and find that after the passage of the waves both the kinetic energy and the angular momentum per unit mass of the particles are changed. Therefore there is a transfer of energy and angular momentum between the gravitational field and the free particles, so that the final values of the energy and angular momentum of the free particles may be smaller or larger in magnitude than the initial values.

  2. Rigidly rotating zero-angular-momentum observer surfaces in the Kerr spacetime

    NASA Astrophysics Data System (ADS)

    Frolov, Andrei V.; Frolov, Valeri P.

    2014-12-01

    A stationary observer in the Kerr spacetime has zero angular momentum if their angular velocity ω has a particular value, which depends on the position of the observer. Worldlines of such zero-angular-momentum observers (ZAMOs) with the same value of the angular velocity ω form a three-dimensional surface, which has the property that the Killing vectors generating time translation and rotation are tangent to it. We call such a surface a rigidly rotating ZAMO surface. This definition allows for a natural generalization to the surfaces inside the black hole, where ZAMO trajectories formally become spacelike. A general property of such a surface is that there exist linear combinations of the Killing vectors with constant coefficients which make them orthogonal on it. In this paper we discuss properties of the rigidly rotating ZAMO surfaces both outside and inside the black hole and the relevance of these objects to a couple of interesting physical problems.

  3. Evaluation of Suited and Unsuited Human Functional Strength Using Multipurpose, Multiaxial Isokinetic Dynamometer

    NASA Technical Reports Server (NTRS)

    Aghazadeh, Fred

    2005-01-01

    The objective of the planned summer research was to develop a procedure to determine the isokinetic functional strength of suited and unsuited participants in order to estimate the coefficient of micro-gravity suit on human strength. To accomplish this objective, the Anthropometry and Biomechanics Facility's Multipurpose, Multiaxial Isokinetic dynamometer (MMID) was used. Development of procedure involved selection and testing of seven routines to be tested on MMID. We conducted the related experiments and collected the data for 12 participants. In addition to the above objective, we developed a procedure to assess the fatiguing characteristics of suited and unsuited participants using EMG technique. We collected EMG data on 10 participants while performing a programmed routing on MMID. EMG data along with information on the exerted forces, effector speed, number of repetitions, and duration of each routine were recorded for further analysis. Finally, gathering and tabulation Of data for various human strengths for updating of MSIS (HSIS) strength requirement, which started in summer 2003, also continued.

  4. Influence of Isokinetic Strength Training of Unilateral Ankle on Ipsilateral One-legged Standing Balance of Adults

    PubMed Central

    Son, Sung Min; Kang, Kyung Woo; Lee, Na Kyung; Nam, Seok Hyun; Kwon, Jung Won; Kim, Kyoung

    2013-01-01

    [Purpose] The purpose of the current study was to investigate the changes in one-legged standing balance of the ipsilateral lower limb following unilateral isokinetic strength training. [Subjects and Methods] Thirty healthy adult volunteers were randomly assigned to either a training group or a control group, so that each group included 15 subjects. Subjects in the training group performed unilateral ankle isokinetic exercises of the dominant leg using the Biodex 3 PRO System for a period of four weeks. Ipsilateral one-legged standing balance was evaluated before and after the intervention with three stability indexes of balance using the Biodex System: Anterior-Posterior Stability Index (APSI), Medial-Lateral Stability Index (MLSI), and Overall Stability Index (OSI). [Results] Comparison of pre- and post-test data revealed significant improvements in strength values (dorsiflexion, plantarflexion, eversion, and inversion) and stability indexes (APSI, MLSI, OSI). [Conclusion] These results suggest that ankle strengthening exercise can be considered as a form of exercise that may assist individuals with improvement of balance. PMID:24259783

  5. The elastic theory of shells using geometric algebra

    PubMed Central

    Lasenby, J.; Agarwal, A.

    2017-01-01

    We present a novel derivation of the elastic theory of shells. We use the language of geometric algebra, which allows us to express the fundamental laws in component-free form, thus aiding physical interpretation. It also provides the tools to express equations in an arbitrary coordinate system, which enhances their usefulness. The role of moments and angular velocity, and the apparent use by previous authors of an unphysical angular velocity, has been clarified through the use of a bivector representation. In the linearized theory, clarification of previous coordinate conventions which have been the cause of confusion is provided, and the introduction of prior strain into the linearized theory of shells is made possible. PMID:28405404

  6. The elastic theory of shells using geometric algebra.

    PubMed

    Gregory, A L; Lasenby, J; Agarwal, A

    2017-03-01

    We present a novel derivation of the elastic theory of shells. We use the language of geometric algebra, which allows us to express the fundamental laws in component-free form, thus aiding physical interpretation. It also provides the tools to express equations in an arbitrary coordinate system, which enhances their usefulness. The role of moments and angular velocity, and the apparent use by previous authors of an unphysical angular velocity, has been clarified through the use of a bivector representation. In the linearized theory, clarification of previous coordinate conventions which have been the cause of confusion is provided, and the introduction of prior strain into the linearized theory of shells is made possible.

  7. Isokinetic and Electromyographic Properties of Muscular Endurance in Short and Long-Term Type 2 Diabetes

    PubMed Central

    Hatef, Boshra; Ghanjal, Ali; Meftahi, Gholam Hossein; Askary-Ashtiani, Ahmadreza

    2016-01-01

    Background: Patients with type 2 diabetes mellitus (T2DM) are subject to progressive reduction of muscle mass and strength. The aim of this study was to assess muscle forces and electromyography (EMG) indices in short and long-term diabetes during an isokinetic exercise. Methods: The peak torque, work, mean power frequency (MPF) and root mean square (RMS) of knee flexors and extensors during 40 isokinetic knee extension-flexion repetitions with a velocity of 150 degree/s were recorded. 18 patients with less than 10 years with T2DM and 12 patients with equal and more than 10 years of disease were compared with 20 gender, body mass index, physical activity and peripheral circulation matched healthy controls. Results: The fatigue index and slope of line across the peak torque values of the knee flexor indicate that patients with long-term T2DM were significantly more resistant to fatigue in comparison with the two other groups (p<0.009). Whereas the MPF decrease during isokinetic protocol interact with grouping in the medial hamstring (p<0.042), but it was independent to groups in other muscles (p<0.0001). The increase of RMS after fatigue protocol interacted with sex for the medial hamstring and vastus lateralis (p<0.039) and interacted with group for the extensor muscles (p<0.045). Discussion & Conclusion: It seems that long-term T2DM cause some neuromuscular adaptations to maintain knee flexor muscle performance during functional activity especially postural control. PMID:27045412

  8. Effect of a lateral step-up exercise protocol on quadriceps and lower extremity performance.

    PubMed

    Worrell, T W; Borchert, B; Erner, K; Fritz, J; Leerar, P

    1993-12-01

    Closed kinetic chain exercises have been promoted as more functional and more appropriate than open kinetic chain exercises. Limited research exists demonstrating the effect of closed kinetic chain exercise on quadriceps and lower extremity performance. The purpose of this study was to determine the effect of a lateral step-up exercise protocol on isokinetic quadriceps peak torque and the following lower extremity activities: 1) leg press, 2) maximal step-up repetitions with body weight plus 25%, 3) hop for distance, and 4) 6-m timed hop. Twenty subjects participated in a 4-week training period, and 18 subjects served as controls. For the experimental group, a repeated measure ANOVA comparing pretest and posttest values revealed significant improvements in the leg press (p < or = .05), step-ups (p < or = .05), hop for distance (p < or = .05), and hop for time (p < or = .05) and no significant increase in isokinetic quadriceps peak torque (p > or = .05). Over the course of the training period, weight used for the step-up exercise increased (p < or = .05), repetitions decreased (p < or = .05), and step-up work did not change (p > or = .05). For the control group, no significant change (p > or = .05) occurred in any variable. The inability of the isokinetic dynamometer to detect increases in quadriceps performance is important because the isokinetic values are frequently used as criteria for return to functional activities. We conclude that closed kinetic chain testing and exercise provide additional means to assess and rehabilitate the lower extremity.

  9. Searching for a 4 α linear-chain structure in excited states of 16O with covariant density functional theory

    NASA Astrophysics Data System (ADS)

    Yao, J. M.; Itagaki, N.; Meng, J.

    2014-11-01

    A study of the 4 α linear-chain structure in high-lying collective excitation states of 16O with covariant density functional theory is presented. The low-spin states are obtained by configuration mixing of particle-number and angular-momentum projected quadrupole deformed mean-field states with the generator coordinate method. The high-spin states are determined by cranking calculations. These two calculations are based on the same energy density functional PC-PK1. We have found a rotational band at low spin with the dominant intrinsic configuration considered to be the one whereby 4 α clusters stay along a common axis. The strongly deformed rod shape also appears in the high-spin region with the angular momentum 13 ℏ to18 ℏ ; however, whether the state is a pure 4 α linear chain is less obvious than for the low-spin states.

  10. dxz/yz subband structure and Chiral Orbital Angular Momentum of Nb doped SrTiO3 surface states

    NASA Astrophysics Data System (ADS)

    Soltani, Shoresh; Cho, Soohyun; Ryu, Hanyoung; Han, Garam; Kim, Timur; Hoesch, Moritz; Kim, Changyoung

    Using angle resolved photoemission spectroscopy (ARPES), we investigate subband structure and chiral orbital angular momentum (OAM) texture on the surface of lightly electron doped SrTiO3 single crystals. Our linearly polarized light ARPES data taken with 51 eV photons, reveal additional subbands for out-of-plane dxz/yzorbitals in addition to the previously reported ones. Our CD-ARPES data reveal a chiral OAM structure which we use as a clue to explain the origin of linear Rashba-like surface band splitting of Ti 3d t2g orbitals. The observed CD signal is enhanced near crossing points, where different orbitals hybridize, compatible with a linear Rashba-like surface band splitting. The work was supported by IBS-R009-G2. S.S., S.C., H.Y. and G. H. acknowledge were supported by Yonsei university, BK21 program.

  11. Angular and linear fields of view of Galilean telescopes and telemicroscopes.

    PubMed

    Katz, Milton

    2007-06-01

    The calculation of the angular fields of view (FOVs) of Galilean telescopes generally necessitates the calculation of the pupils and ports. This, in turn, requires knowledge of the optical design of the telescope, in particular, the focal lengths or powers of the objective and ocular lenses. Equations for finding the FOV that obviate the need to calculate pupils and ports, or even to know the lens powers of the telescope, are presented in this article. The equations can be used to find the FOVs in image space of real Galilean telescopes of known magnification, merely by measuring the distance between the objective and ocular lenses and the diameter of the objective lens. The equations include the effects of eye pupil diameter and eye relief. Linear FOVs (LFOVs) of Galilean telemicroscopes are similarly determined. Two image space angular FOV equations were derived: (1) an equation to determine the angular FOVs of a telescope with various amounts of vignetting and eye relief; and (2) an equivalent equation for the LFOVs of telescopes fitted with lens caps for near vision. The FOV increases linearly with increasing vignetting. Increasing the eye relief results in a nonlinear decrease in the FOV, shown as a fraction of the normalized value for zero eye relief. Decrements in the FOVs with increasing eye relief as a fraction of the normalized field angle when the eye relief = 0 are shown to be constant regardless of the vignetting level. A transition of the objective lens from field stop to aperture stop occurs when the eye pupil diameter exceeds the diameter of the objective lens divided by the magnification. Equations have been derived for Galilean telescopes and telemicroscopes that make it unnecessary to find pupils and ports, or to know the powers of the lenses. They provide a direct and simple evaluation of angular and LFOVs as functions of magnification, objective lens diameter, eye pupil diameter, eye relief, and vignetting, and enable comparisons of actual telescopes.

  12. Optically Stimulated Luminescent Dosimetry for High Dose Rate Brachytherapy

    PubMed Central

    Tien, Christopher Jason; Ebeling, Robert; Hiatt, Jessica R.; Curran, Bruce; Sternick, Edward

    2012-01-01

    Purpose: The objective was to determine whether optically stimulated luminescent dosimeters (OSLDs) were appropriate for in vivo measurements in high dose rate brachytherapy. In order to make this distinction, three dosimetric characteristics were tested: dose linearity, dose rate dependence, and angular dependence. The Landauer nanoDot™ OSLDs were chosen due to their popularity and their availability commercially. Methods: To test the dose linearity, each OSLD was placed at a constant location and the dwell time was varied. Next, in order to test the dose rate dependence, each OSLD was placed at different OLSD-to-source distances and the dwell time was held constant. A curved geometry was created using a circular Accuboost® applicator in order to test angular dependence. Results: The OSLD response remained linear for high doses and was independent of dose rate. For doses up to 600 cGy, the linear coefficient of determination was 0.9988 with a response of 725 counts per cGy. The angular dependence was significant only in “edge-on” scenarios. Conclusion: OSLDs are conveniently read out using commercially available readers. OSLDs can be re-read and serve as a permanent record for clinical records or be annealed using conventional fluorescent light. Lastly, OSLDs are produced commercially for $5 each. Due to these convenient features, in conjunction with the dosimetric performance, OSLDs should be considered a clinically feasible and attractive tool for in vivo HDR brachytherapy measurements. PMID:22888476

  13. Quantification of toy sword kinematics with male pediatric volunteers.

    PubMed

    Beeman, Stephanie M; Rowson, Steven; Duma, Stefan M

    2014-01-01

    While extensive research in toy safety has been performed, data is unavailable with regard to the kinematics of toy swords. To improve upon design criteria, knowledge of a child’s physical capacity is essential. The purpose of this study was to quantify the linear and angular velocities generated by children swinging toy swords. A total of 36 male subjects, ages 4-14 years old, each participated in one trial. Subjects were instructed to swing a toy sword as fast and hard as possible for ~10 seconds. A Vicon motion analysis system was used to capture subject and sword kinematics. Peak linear and angular sword velocities were calculated. A strong correlation was identified between age and velocity. The 8-14 year old males were not significantly different. The 4 year old males generated significantly lower velocities than the 8-14 year old males. The 6 year old males produced significantly lower velocities than the 10- 14 year old males. It was concluded that age had a significant effect on the linear and angular velocities generated by children. The trends observed within this study likely result from typical pediatric and adolescent development. By accounting for the physical capabilities of a specific population, toys can be designed with decreased inherent risks of injury.

  14. Remotely detected vehicle mass from engine torque-induced frame twisting

    NASA Astrophysics Data System (ADS)

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.; Sweeney, Glenn D.

    2017-06-01

    Determining the mass of a vehicle from ground-based passive sensor data is important for many traffic safety requirements. This work presents a method for calculating the mass of a vehicle using ground-based video and acoustic measurements. By assuming that no energy is lost in the conversion, the mass of a vehicle can be calculated from the rotational energy generated by the vehicle's engine and the linear acceleration of the vehicle over a period of time. The amount of rotational energy being output by the vehicle's engine can be calculated from its torque and angular velocity. This model relates remotely observed, engine torque-induced frame twist to engine torque output using the vehicle's suspension parameters and engine geometry. The angular velocity of the engine is extracted from the acoustic emission of the engine, and the linear acceleration of the vehicle is calculated by remotely observing the position of the vehicle over time. This method combines these three dynamic signals; engine induced-frame twist, engine angular velocity, and the vehicle's linear acceleration, and three vehicle specific scalar parameters, into an expression that describes the mass of the vehicle. This method was tested on a semitrailer truck, and the results demonstrate a correlation of 97.7% between calculated and true vehicle mass.

  15. Conical Pendulum--Linearization Analyses

    ERIC Educational Resources Information Center

    Dean, Kevin; Mathew, Jyothi

    2016-01-01

    A theoretical analysis is presented, showing the derivations of seven different linearization equations for the conical pendulum period "T", as a function of radial and angular parameters. Experimental data obtained over a large range of fixed conical pendulum lengths (0.435 m-2.130 m) are plotted with the theoretical lines and…

  16. Coordinate measuring system

    DOEpatents

    Carlisle, Keith [Discovery Bay, CA

    2003-04-08

    An apparatus and method is utilized to measure relative rigid body motion between two bodies by measuring linear motion in the principal axis and linear motion in an orthogonal axis. From such measurements it is possible to obtain displacement, departure from straightness, and angular displacement from the principal axis of a rigid body.

  17. Influence of prolonged intermittent high-intensity exercise on knee flexor strength in male and female soccer players.

    PubMed

    Mercer, Tom H; Gleeson, Nigel P; Wren, Karen

    2003-06-01

    This study investigated the effect of an acute, prolonged, intermittent, high-intensity single-leg pedalling exercise task (PIHIET) on the isokinetic leg strength of the knee flexors in six male and seven female collegiate soccer players. Following determination of single-leg VO(2peak), subjects completed a PIHIET designed to simulate the energetics of soccer match play (approximately 90 min in total; approximately 70% single-leg VO(2peak)). Pre-, mid- and post-PIHIET gravity-corrected indices of knee flexion peak torque (PT) and range of motion-relativised torque at 15% of knee flexion (RRT(15%); 0% = full knee extension) were assessed at a lever-arm angular velocity of 1.05 rad.s(-1)for intervention and control limbs using an isokinetic dynamometer. Repeated measures ANOVAs revealed significant condition (PIHIET, control) x time (pre-, mid-, post-PIHIET) interactions for knee flexion PT (F([2,22])=26.2; P<0.001) and RRT(15%) (F([2,22])=20.1; P<0.001). Flexion PT and RRT(15% )were observed to decrease, pre- to post-intervention, from 92.8 (28.7) N.m to 72.1 (28.0) N.m and from 63.8 (17.5) N.m to 47.9 (18.4) N.m respectively, for the intervention limb alone. These data corresponded to 22.3% and 24.9% mean reductions pre-post intervention in PT and RRT(15%). Exploratory post hoc analysis of the pattern of the relative deterioration (%) of PT and RRT(15%), for the intervention limb alone, revealed a three-way interaction [group (male, female) x parameter (PT, RRT(15%)) x assessment phase (pre- to mid-PIHIET, mid- to post-PIHIET)] (F(1,11)=5.2; P<0.05). This interaction characterised a greater deterioration of strength performance during the mid- to post-PIHIET assessment phase, at the extremes of range of motion (RRT(15%)) for the female group. The greater percentage of mid-post phase strength loss observed in women near the end-range extension may potentially be implicated in the higher incidence of knee injury reported in female soccer players.

  18. Mid-IR Lasers: Challenges Imposed by the Population Dynamics of the Gain System

    DTIC Science & Technology

    2010-09-01

    MicroSystems (IOMS) Central-Field Approximation: Perturbations 1. a) Non-centrosymmetric splitting (Coulomb interaction) ⇒ total orbital angular momentum b...Accordingly: ⇒ total electron-spin momentum 2. Spin-orbit coupling (“LS” coupling) ⇒ total angular momentum lanthanides: intermediate coupling (LS / jj) 3...MicroSystems (IOMS) Luminescence Decay Curves Rate-equation for decay: Solution ( Bernoulli -Eq.): Linearized solution: T. Jensen, Ph.D. Thesis, Univ. Hamburg

  19. Angular intensity and polarization dependence of diffuse transmission through random media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eliyahu, D.; Rosenbluh, M.; Feund, I.

    1993-03-01

    A simple theoretical model involving only a single sample parameter, the depolarization ratio [rho] for linearly polarized normally incident and normally scattered light, is developed to describe the angular intensity and all other polarization-dependent properties of diffuse transmission through multiple-scattering media. Initial experimental results that tend to support the theory are presented. Results for diffuse reflection are also described. 63 refs., 15 figs.

  20. CMB hemispherical asymmetry from non-linear isocurvature perturbations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Assadullahi, Hooshyar; Wands, David; Firouzjahi, Hassan

    2015-04-01

    We investigate whether non-adiabatic perturbations from inflation could produce an asymmetric distribution of temperature anisotropies on large angular scales in the cosmic microwave background (CMB). We use a generalised non-linear δ N formalism to calculate the non-Gaussianity of the primordial density and isocurvature perturbations due to the presence of non-adiabatic, but approximately scale-invariant field fluctuations during multi-field inflation. This local-type non-Gaussianity leads to a correlation between very long wavelength inhomogeneities, larger than our observable horizon, and smaller scale fluctuations in the radiation and matter density. Matter isocurvature perturbations contribute primarily to low CMB multipoles and hence can lead to a hemisphericalmore » asymmetry on large angular scales, with negligible asymmetry on smaller scales. In curvaton models, where the matter isocurvature perturbation is partly correlated with the primordial density perturbation, we are unable to obtain a significant asymmetry on large angular scales while respecting current observational constraints on the observed quadrupole. However in the axion model, where the matter isocurvature and primordial density perturbations are uncorrelated, we find it may be possible to obtain a significant asymmetry due to isocurvature modes on large angular scales. Such an isocurvature origin for the hemispherical asymmetry would naturally give rise to a distinctive asymmetry in the CMB polarisation on large scales.« less

  1. Effect of implant angulation and impression technique on impressions of NobelActive implants.

    PubMed

    Alexander Hazboun, Gillian Brewer; Masri, Radi; Romberg, Elaine; Kempler, Joanna; Driscoll, Carl F

    2015-05-01

    How the configuration of the NobelActive internal conical connection affects implant impressions is uncertain. The purpose of this study was to measure the effect in vitro of closed and open tray impression techniques for NobelActive implants placed at various angulations. Six NobelActive implants were placed in a master maxillary cast as follows: 0 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first molar area, 15 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first premolar area, and 30 degrees of angulation to a line drawn perpendicular to the occlusal plane in the lateral incisor area. Twelve open tray and 12 closed tray impressions were made. Occlusal, lateral, and frontal view photographs of the resulting casts were used to measure the linear and angular displacement of implant analogs. Statistical analysis was performed with a factorial analysis of variance (ANOVA), followed by the Tukey HSD test (α=.05). No significant difference was found in the impressions made of NobelActive implants with the open or closed tray technique (linear displacement: F=0.93, P=.34; angular displacement: F=2.09, P=.15). In addition, implant angulation (0, 15, or 30 degrees) had no effect on the linear or angular displacement of impressions (linear displacement: F=2.72, P=.07; angular displacement: F=0.86, P=.43). Finally, no significant interaction was found between impression technique and implant angulation on NobelActive implants (F=0.25, P=.77; F=1.60, P=.20). Within the limitations of this study, impression technique (open vs closed tray) and implant angulation (0, 15, and 30 degrees) had no significant effect on in vitro impressions of NobelActive implants. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Predictors of chronic ankle instability: Analysis of peroneal reaction time, dynamic balance and isokinetic strength.

    PubMed

    Sierra-Guzmán, Rafael; Jiménez, Fernando; Abián-Vicén, Javier

    2018-05-01

    Previous studies have reported the factors contributing to chronic ankle instability, which could lead to more effective treatments. However, factors such as the reflex response and ankle muscle strength have not been taken into account in previous investigations. Fifty recreational athletes with chronic ankle instability and 55 healthy controls were recruited. Peroneal reaction time in response to sudden inversion, isokinetic evertor muscle strength and dynamic balance with the Star Excursion Balance Test and the Biodex Stability System were measured. The relationship between the Cumberland Ankle Instability Tool score and performance on each test was assessed and a backward multiple linear regression analysis was conducted. Participants with chronic ankle instability showed prolonged peroneal reaction time, poor performance in the Biodex Stability System and decreased reach distance in the Star Excursion Balance Test. No significant differences were found in eversion and inversion peak torque. Moderate correlations were found between the Cumberland Ankle Instability Tool score and the peroneal reaction time and performance on the Star Excursion Balance Test. Peroneus brevis reaction time and the posteromedial and lateral directions of the Star Excursion Balance Test accounted for 36% of the variance in the Cumberland Ankle Instability Tool. Dynamic balance deficits and delayed peroneal reaction time are present in participants with chronic ankle instability. Peroneus brevis reaction time and the posteromedial and lateral directions of the Star Excursion Balance Test were the main contributing factors to the Cumberland Ankle Instability Tool score. No clear strength impairments were reported in unstable ankles. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Acute effects of dynamic exercises on the relationship between the motor unit firing rate and the recruitment threshold.

    PubMed

    Ye, Xin; Beck, Travis W; DeFreitas, Jason M; Wages, Nathan P

    2015-04-01

    The aim of this study was to compare the acute effects of concentric versus eccentric exercise on motor control strategies. Fifteen men performed six sets of 10 repetitions of maximal concentric exercises or eccentric isokinetic exercises with their dominant elbow flexors on separate experimental visits. Before and after the exercise, maximal strength testing and submaximal trapezoid isometric contractions (40% of the maximal force) were performed. Both exercise conditions caused significant strength loss in the elbow flexors, but the loss was greater following the eccentric exercise (t=2.401, P=.031). The surface electromyographic signals obtained from the submaximal trapezoid isometric contractions were decomposed into individual motor unit action potential trains. For each submaximal trapezoid isometric contraction, the relationship between the average motor unit firing rate and the recruitment threshold was examined using linear regression analysis. In contrast to the concentric exercise, which did not cause significant changes in the mean linear slope coefficient and y-intercept of the linear regression line, the eccentric exercise resulted in a lower mean linear slope and an increased mean y-intercept, thereby indicating that increasing the firing rates of low-threshold motor units may be more important than recruiting high-threshold motor units to compensate for eccentric exercise-induced strength loss. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Ring Laser Gyro G-Sensitive Misalignment Calibration in Linear Vibration Environments.

    PubMed

    Wang, Lin; Wu, Wenqi; Li, Geng; Pan, Xianfei; Yu, Ruihang

    2018-02-16

    The ring laser gyro (RLG) dither axis will bend and exhibit errors due to the specific forces acting on the instrument, which are known as g-sensitive misalignments of the gyros. The g-sensitive misalignments of the RLG triad will cause severe attitude error in vibration or maneuver environments where large-amplitude specific forces and angular rates coexist. However, g-sensitive misalignments are usually ignored when calibrating the strapdown inertial navigation system (SINS). This paper proposes a novel method to calibrate the g-sensitive misalignments of an RLG triad in linear vibration environments. With the SINS is attached to a linear vibration bench through outer rubber dampers, rocking of the SINS can occur when the linear vibration is performed on the SINS. Therefore, linear vibration environments can be created to simulate the harsh environment during aircraft flight. By analyzing the mathematical model of g-sensitive misalignments, the relationship between attitude errors and specific forces as well as angular rates is established, whereby a calibration scheme with approximately optimal observations is designed. Vibration experiments are conducted to calibrate g-sensitive misalignments of the RLG triad. Vibration tests also show that SINS velocity error decreases significantly after g-sensitive misalignments compensation.

  5. Vectorial control of nonlinear emission via chiral butterfly nanoantennas: generation of pure high order nonlinear vortex beams.

    PubMed

    Lesina, Antonino Cala'; Berini, Pierre; Ramunno, Lora

    2017-02-06

    We report on a chiral gap-nanostructure, which we term a "butterfly nanoantenna," that offers full vectorial control over nonlinear emission. The field enhancement in its gap occurs for only one circular polarization but for every incident linear polarization. As the polarization, phase and amplitude of the linear field in the gap are highly controlled, the linear field can drive nonlinear emitters within the gap, which behave as an idealized Huygens source. A general framework is thereby proposed wherein the butterfly nanoantennas can be arranged in a metasurface, and the nonlinear Huygens sources exploited to produce a highly structured far-field optical beam. Nonlinearity allows us to shape the light at shorter wavelengths, not accessible by linear plasmonics, and resulting in high purity beams. The chirality of the butterfly allows us to create orbital angular momentum states using a linearly polarized excitation. A third harmonic Laguerre-Gauss beam carrying an optical orbital angular momentum of 41 is demonstrated as an example, through large-scale simulations on a high-performance computing platform of the full plasmonic metasurface with an area large enough to contain up to 3600 nanoantennas.

  6. Mechanical evidence of the orbital angular momentum to energy ratio of vortex beams.

    PubMed

    Demore, Christine E M; Yang, Zhengyi; Volovick, Alexander; Cochran, Sandy; MacDonald, Michael P; Spalding, Gabriel C

    2012-05-11

    We measure, in a single experiment, both the radiation pressure and the torque due to a wide variety of propagating acoustic vortex beams. The results validate, for the first time directly, the theoretically predicted ratio of the orbital angular momentum to linear momentum in a propagating beam. We experimentally determine this ratio using simultaneous measurements of both the levitation force and the torque on an acoustic absorber exerted by a broad range of helical ultrasonic beams produced by a 1000-element matrix transducer array. In general, beams with helical phase fronts have been shown to contain orbital angular momentum as the result of the azimuthal component of the Poynting vector around the propagation axis. Theory predicts that for both optical and acoustic helical beams the ratio of the angular momentum current of the beam to the power should be given by the ratio of the beam's topological charge to its angular frequency. This direct experimental observation that the ratio of the torque to power does convincingly match the expected value (given by the topological charge to angular frequency ratio of the beam) is a fundamental result.

  7. An inventory on rotational kinematics of a particle: unravelling misconceptions and pitfalls in reasoning

    NASA Astrophysics Data System (ADS)

    Mashood, K. K.; Singh, Vijay A.

    2012-09-01

    Student difficulties regarding the angular velocity (\\vec{\\omega }) and angular acceleration (\\vec{\\alpha }) of a particle have remained relatively unexplored in contrast to their linear counterparts. We present an inventory comprising multiple choice questions aimed at probing misconceptions and eliciting ill-suited reasoning patterns. The development of the inventory was based on interactions with students, teachers and experts. We report misconceptions, some of which are parallel to those found earlier in linear kinematics. Fixations with inappropriate prototypes were uncovered. Many students and even teachers mistakenly assume that all rotational motion is necessarily circular. A persistent notion that the direction of \\vec{\\omega } and \\vec{\\alpha } should be ‘along’ the motion exists. Instances of indiscriminate usage of equations were identified.

  8. Superconducting tensor gravity gradiometer for satellite geodesy and inertial navigation

    NASA Technical Reports Server (NTRS)

    Paik, H. J.

    1981-01-01

    A sensitive gravity gradiometer can provide much needed gravity data of the earth and improve the accuracy of inertial navigation. Superconductivity and other properties of materials at low temperatures can be used to obtain a sensitive, low-drift gravity gradiometer; by differencing the outputs of accelerometer pairs using superconducting circuits, it is possible to construct a tensor gravity gradiometer which measures all the in-line and cross components of the tensor simultaneously. Additional superconducting circuits can be provided to determine the linear and angular acceleration vectors. A tensor gravity gradiometer with these features is being developed for satellite geodesy. The device constitutes a complete package of inertial navigation instruments with angular and linear acceleration readouts as well as gravity signals.

  9. Comparisons in the Recovery Response From Resistance Exercise Between Young and Middle-Aged Men.

    PubMed

    Gordon, Joseph A; Hoffman, Jay R; Arroyo, Eliott; Varanoske, Alyssa N; Coker, Nicholas A; Gepner, Yftach; Wells, Adam J; Stout, Jeffrey R; Fukuda, David H

    2017-12-01

    Gordon, JA III, Hoffman, JR, Arroyo, E, Varanoske, AN, Coker, NA, Gepner, Y, Wells, AJ, Stout, JR, and Fukuda, DH. Comparisons in the recovery response from resistance exercise between young and middle-aged men. J Strength Cond Res 31(12): 3454-3462, 2017-The purpose of this study was to compare the effects of a bout of high-volume isokinetic resistance exercise protocol (HVP) on lower-body strength and markers of inflammation and muscle damage during recovery between young and middle-aged adult men. Nineteen recreationally trained men were classified as either a young adult (YA: 21.8 ± 2.0 years; 90.7 ± 11.6 kg) or a middle-aged adult (MA: 47.0 ± 4.4 years; 96.0 ± 21.5 kg) group. The HVP consisted of 8 sets of 10 repetitions, with 1 minute of rest between each set, performed on an isokinetic dynamometer at 60°·s. Maximal voluntary isometric contractions and isokinetic peak torque (PKT) and average torque (AVGT) (measured at 240° and 60°·s, respectively) were assessed at baseline (BL), immediately post (IP), 120 minutes, 24, and 48 hours after HVP. Blood was obtained at BL, IP, 30, 60, 120 minute, 24, and 48 hours after HVP to assess muscle damage and inflammation. All performance data were analyzed using repeated measures analysis of covariance, whereas all inflammatory and muscle damage markers were analyzed using a 2-way (time × group) repeated measures analysis of variance. Results revealed no between-group differences for PKT, AVGT, or rate of torque development at 200 ms (RTD200). No between-group differences in myoglobin, creatine kinase, C-reactive protein, or interleukin-6 were observed. Although BL differences in muscle performance were observed between YA and MA, no between-group differences were noted in performance recovery measures from high-volume isokinetic exercise in recreationally trained men. These results also indicate that the inflammatory and muscle damage response from high-volume isokinetic exercise is similar between recreationally trained, young, and middle-aged adult men.

  10. Test-retest reliability of cardinal plane isokinetic hip torque and EMG.

    PubMed

    Claiborne, Tina L; Timmons, Mark K; Pincivero, Danny M

    2009-10-01

    The objective of the present study was to establish test-retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC - 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range=0.81-0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range=0.49-0.79). The majority of the EMG sampled muscles (n=12 and n=11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC=0.81-0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.

  11. Strength deficits of the shoulder complex during isokinetic testing in people with chronic stroke

    PubMed Central

    Nascimento, Lucas R.; Teixeira-Salmela, Luci F.; Polese, Janaine C.; Ada, Louise; Faria, Christina D. C. M.; Laurentino, Glória E. C.

    2014-01-01

    OBJECTIVES: To examine the strength deficits of the shoulder complex after stroke and to characterize the pattern of weakness according to type of movement and type of isokinetic parameter. METHOD: Twelve chronic stroke survivors and 12 age-matched healthy controls had their shoulder strength measured using a Biodex isokinetic dynamometer. Concentric measures of peak torque and work during shoulder movements were obtained in random order at speeds of 60°/s for both groups and sides. Type of movement was defined as scapulothoracic (protraction and retraction), glenohumeral (shoulder internal and external rotation) or combined (shoulder flexion and extension). Type of isokinetic parameter was defined as maximum (peak torque) or sustained (work). Strength deficits were calculated using the control group as reference. RESULTS: The average strength deficit for the paretic upper limb was 52% for peak torque and 56% for work. Decreases observed in the non-paretic shoulder were 21% and 22%, respectively. Strength deficit of the scapulothoracic muscles was similar to the glenohumeral muscles, with a mean difference of 6% (95% CI -5 to 17). Ability to sustain torque throughout a given range of motion was decreased as much as the peak torque, with a mean difference of 4% (95% CI -2 to 10). CONCLUSIONS: The findings suggest that people after stroke might benefit from strengthening exercises directed at the paretic scapulothoracic muscles in addition to exercises of arm elevation. Clinicians should also prescribe different exercises to improve the ability to generate force and the ability to sustain the torque during a specific range of motion. PMID:25003280

  12. Reliability and relationships among handgrip strength, leg extensor strength and power, and balance in older men.

    PubMed

    Jenkins, Nathaniel D M; Buckner, Samuel L; Bergstrom, Haley C; Cochrane, Kristen C; Goldsmith, Jacob A; Housh, Terry J; Johnson, Glen O; Schmidt, Richard J; Cramer, Joel T

    2014-10-01

    To quantify the reliability of isometric leg extension torque (LEMVC), rate of torque development (LERTD), isometric handgrip force (HGMVC) and RFD (HGRFD), isokinetic leg extension torque and power at 1.05rad·s(-1) and 3.14rad·s(-1); and explore relationships among strength, power, and balance in older men. Sixteen older men completed 3 isometric handgrips, 3 isometric leg extensions, and 3 isokinetic leg extensions at 1.05rad·s(-1) and 3.14rad·s(-1) during two visits. Intraclass correlation coefficients (ICCs), ICC confidence intervals (95% CI), coefficients of variation (CVs), and Pearson correlation coefficients were calculated. LERTD demonstrated no reliability. The CVs for LERTD and HGRFD were ≤23.26%. HGMVC wasn't related to leg extension torque or power, or balance (r=0.14-0.47; p>0.05). However, moderate to strong relationships were found among isokinetic leg extension torque at 1.05rad·s(-1) and 3.14rad·s(-1), leg extension mean power at 1.05rad·s(-1), and functional reach (r=0.51-0.95; p≤0.05). LERTD and HGRFD weren't reliable and shouldn't be used as outcome variables in older men. Handgrip strength may not be an appropriate surrogate for lower body strength, power, or balance. Instead, perhaps handgrip strength should only be used to describe upper body strength or functionality, which may compliment isokinetic assessments of lower body strength, which were reliable and related to balance. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Shoulder isokinetic profile of male handball players of the Brazilian National Team

    PubMed Central

    Andrade, Marília S.; Vancini, Rodrigo L.; de Lira, Claudio A. B.; Mascarin, Naryana C.; Fachina, Rafael J. F. G.; da Silva, Antonio C.

    2013-01-01

    Background Data obtained on an isokinetic dynamometer are useful to characterize muscle status and have been reported in muscle imbalance studies in different types of sport. However, few studies have assessed elite handball players to establish reference values. Objective The purpose of this study was to compare, for the dominant (D) and non-dominant (ND) side, the isokinetic profile of shoulder rotator muscle strength between male handball players (H) and asymptomatic non-athletes (NA). Method Isokinetic concentric and eccentric strength tests for D upper limbs were performed by the H group (n=20) and the NA group (n=12). Internal and external rotator muscle peak torque in concentric action was assessed at 60°/s and 300°/s and in eccentric action at 300°/s. We also calculated conventional balance (the ratio of external rotator peak torque to internal rotator peak torque in concentric action) and functional balance (the ratio of external rotator peak torque in eccentric action to internal rotator peak torque in concentric action). Results In the H group, dominant limbs were stronger in concentric action for external rotation at 60 and 300°/s. The conventional balance ratio for the D side was significantly lower at 60 and 300°/s for H compared to NA. The functional ratio for the D side was significantly lower at 300º/s for H compared to NA. Conclusions Compared to asymptomatic non-athletes, handball players presented significant muscular imbalance resulting from daily sports practice, a known risk factor for shoulder injuries. PMID:24271090

  14. A GEM readout with radial zigzag strips and linear charge-sharing response

    DOE PAGES

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; ...

    2018-01-10

    Here, we study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures aremore » implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Lastly, angular resolutions of 60–84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.« less

  15. A GEM readout with radial zigzag strips and linear charge-sharing response

    NASA Astrophysics Data System (ADS)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  16. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey.

    PubMed

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Cross-sectional study. Twenty-three female ice hockey players aged 15-25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Regression models (adj R (2)) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Field-based assessments, particularly single-leg tests, are an adequate substitute to more expensive and time-consuming laboratory assessments if the purpose is to gain knowledge about key performance characteristics of skating.

  17. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey

    PubMed Central

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    Objectives The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Design Cross-sectional study. Methods Twenty-three female ice hockey players aged 15–25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Results Regression models (adj R2) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Conclusion Field-based assessments, particularly single-leg tests, are an adequate substitute to more expensive and time-consuming laboratory assessments if the purpose is to gain knowledge about key performance characteristics of skating. PMID:27574474

  18. A Framework for Linear and Non-Linear Registration of Diffusion-Weighted MRIs Using Angular Interpolation

    PubMed Central

    Duarte-Carvajalino, Julio M.; Sapiro, Guillermo; Harel, Noam; Lenglet, Christophe

    2013-01-01

    Registration of diffusion-weighted magnetic resonance images (DW-MRIs) is a key step for population studies, or construction of brain atlases, among other important tasks. Given the high dimensionality of the data, registration is usually performed by relying on scalar representative images, such as the fractional anisotropy (FA) and non-diffusion-weighted (b0) images, thereby ignoring much of the directional information conveyed by DW-MR datasets itself. Alternatively, model-based registration algorithms have been proposed to exploit information on the preferred fiber orientation(s) at each voxel. Models such as the diffusion tensor or orientation distribution function (ODF) have been used for this purpose. Tensor-based registration methods rely on a model that does not completely capture the information contained in DW-MRIs, and largely depends on the accurate estimation of tensors. ODF-based approaches are more recent and computationally challenging, but also better describe complex fiber configurations thereby potentially improving the accuracy of DW-MRI registration. A new algorithm based on angular interpolation of the diffusion-weighted volumes was proposed for affine registration, and does not rely on any specific local diffusion model. In this work, we first extensively compare the performance of registration algorithms based on (i) angular interpolation, (ii) non-diffusion-weighted scalar volume (b0), and (iii) diffusion tensor image (DTI). Moreover, we generalize the concept of angular interpolation (AI) to non-linear image registration, and implement it in the FMRIB Software Library (FSL). We demonstrate that AI registration of DW-MRIs is a powerful alternative to volume and tensor-based approaches. In particular, we show that AI improves the registration accuracy in many cases over existing state-of-the-art algorithms, while providing registered raw DW-MRI data, which can be used for any subsequent analysis. PMID:23596381

  19. Feedforward ankle strategy of balance during quiet stance in adults

    PubMed Central

    Gatev, Plamen; Thomas, Sherry; Kepple, Thomas; Hallett, Mark

    1999-01-01

    We studied quiet stance investigating strategies for maintaining balance. Normal subjects stood with natural stance and with feet together, with eyes open or closed. Kinematic, kinetic and EMG data were evaluated and cross-correlated.Cross-correlation analysis revealed a high, positive, zero-phased correlation between anteroposterior motions of the centre of gravity (COG) and centre of pressure (COP), head and COG, and between linear motions of the shoulder and knee in both sagittal and frontal planes. There was a moderate, negative, zero-phased correlation between the anteroposterior motion of COP and ankle angular motion.Narrow stance width increased ankle angular motion, hip angular motion, mediolateral sway of the COG, and the correlation between linear motions of the shoulder and knee in the frontal plane. Correlations between COG and COP and linear motions of the shoulder and knee in the sagittal plane were decreased. The correlation between the hip angular sway in the sagittal and frontal planes was dependent on interaction between support and vision.Low, significant positive correlations with time lags of the maximum of cross-correlation of 250-300 ms were found between the EMG activity of the lateral gastrocnemius muscle and anteroposterior motions of the COG and COP during normal stance. Narrow stance width decreased both correlations whereas absence of vision increased the correlation with COP.Ankle mechanisms dominate during normal stance especially in the sagittal plane. Narrow stance width decreased the role of the ankle and increased the role of hip mechanisms in the sagittal plane, while in the frontal plane both increased.The modulation pattern of the lateral gastrocnemius muscle suggests a central program of control of the ankle joint stiffness working to predict the loading pattern. PMID:9882761

  20. Response of semicircular canal dependent units in vestibular nuclei to rotation of a linear acceleration vector without angular acceleration

    PubMed Central

    Benson, A. J.; Guedry, F. E.; Jones, G. Melvill

    1970-01-01

    1. Recent experiments have shown that rotation of a linear acceleration vector round the head can generate involuntary ocular nystagmus in the absence of angular acceleration. The present experiments examine the suggestion that adequate stimulation of the semicircular canals may contribute to this response. 2. Decerebrate cats were located in a stereotaxic device on a platform, slung from four parallel cables, which could be driven smoothly round a circular orbit without inducing significant angular movement of the platform. This Parallel Swing Rotation (PSR) generated a centripetal acceleration of 4·4 m/sec2 which rotated round the head at 0·52 rev/sec. 3. The discharge frequency of specifically lateral canal-dependent neural units in the vestibular nuclei of cats was recorded during PSR to right and left, and in the absence of motion. The dynamic responses to purely angular motion were also examined on a servo-driven turntable. 4. Without exception all proven canal-dependent cells examined (twenty-nine cells in nine cats) were more active during PSR in the direction of endolymph circulation assessed to be excitatory to the unit, than during PSR in the opposite direction. 5. The observed changes in discharge frequency are assessed to have been of a magnitude appropriate for the generation of the involuntary oculomotor response induced by the same stimulus in the intact animal. 6. The findings suggest that a linear acceleration vector which rotates in the plane of the lateral semicircular canals can be an adequate stimulus to ampullary receptors, though an explanation which invokes the modulation of canal cells by a signal dependent upon the sequential activation of macular receptors cannot be positively excluded. PMID:5501270

  1. A Framework for Linear and Non-Linear Registration of Diffusion-Weighted MRIs Using Angular Interpolation.

    PubMed

    Duarte-Carvajalino, Julio M; Sapiro, Guillermo; Harel, Noam; Lenglet, Christophe

    2013-01-01

    Registration of diffusion-weighted magnetic resonance images (DW-MRIs) is a key step for population studies, or construction of brain atlases, among other important tasks. Given the high dimensionality of the data, registration is usually performed by relying on scalar representative images, such as the fractional anisotropy (FA) and non-diffusion-weighted (b0) images, thereby ignoring much of the directional information conveyed by DW-MR datasets itself. Alternatively, model-based registration algorithms have been proposed to exploit information on the preferred fiber orientation(s) at each voxel. Models such as the diffusion tensor or orientation distribution function (ODF) have been used for this purpose. Tensor-based registration methods rely on a model that does not completely capture the information contained in DW-MRIs, and largely depends on the accurate estimation of tensors. ODF-based approaches are more recent and computationally challenging, but also better describe complex fiber configurations thereby potentially improving the accuracy of DW-MRI registration. A new algorithm based on angular interpolation of the diffusion-weighted volumes was proposed for affine registration, and does not rely on any specific local diffusion model. In this work, we first extensively compare the performance of registration algorithms based on (i) angular interpolation, (ii) non-diffusion-weighted scalar volume (b0), and (iii) diffusion tensor image (DTI). Moreover, we generalize the concept of angular interpolation (AI) to non-linear image registration, and implement it in the FMRIB Software Library (FSL). We demonstrate that AI registration of DW-MRIs is a powerful alternative to volume and tensor-based approaches. In particular, we show that AI improves the registration accuracy in many cases over existing state-of-the-art algorithms, while providing registered raw DW-MRI data, which can be used for any subsequent analysis.

  2. Haptic control of a pneumatic muscle actuator to provide resistance for simulated isokinetic exercise; part II: control development and testing.

    PubMed

    Hall, Kara L; Phillips, Chandler A; Reynolds, David B; Mohler, Stanley R; Rogers, Dana B; Neidhard-Doll, Amy T

    2015-01-01

    Pneumatic muscle actuators (PMAs) have a high power to weight ratio and possess unique characteristics which make them ideal actuators for applications involving human interaction. PMAs are difficult to control due to nonlinear dynamics, presenting challenges in system implementation. Despite these challenges, PMAs have great potential as a source of resistance for strength training and rehabilitation. The objective of this work was to control a PMA for use in isokinetic exercise, potentially benefiting anyone in need of optimal strength training through a joint's range of motion. The controller, based on an inverse three-element phenomenological model and adaptive nonlinear control, allows the system to operate as a type of haptic device. A human quadriceps dynamic simulator was developed (as described in Part I of this work) so that control effectiveness and accommodation could be tested prior to human implementation. Tracking error results indicate that the control system is effective at producing PMA displacement and resistance necessary for a scaled, simulated neuromuscular actuator to maintain low-velocity isokinetic movement during simulated concentric and eccentric knee extension.

  3. Significance of acceleration period in a dynamic strength testing study.

    PubMed

    Chen, W L; Su, F C; Chou, Y L

    1994-06-01

    The acceleration period that occurs during isokinetic tests may provide valuable information regarding neuromuscular readiness to produce maximal contraction. The purpose of this study was to collect the normative data of acceleration time during isokinetic knee testing, to calculate the acceleration work (Wacc), and to determine the errors (ERexp, ERwork, ERpower) due to ignoring Wacc during explosiveness, total work, and average power measurements. Seven male and 13 female subjects attended the test by using the Cybex 325 system and electronic stroboscope machine for 10 testing speeds (30-300 degrees/sec). A three-way ANOVA was used to assess gender, direction, and speed factors on acceleration time, Wacc, and errors. The results indicated that acceleration time was significantly affected by speed and direction; Wacc and ERexp by speed, direction, and gender; and ERwork and ERpower by speed and gender. The errors appeared to increase when testing the female subjects, during the knee flexion test, or when speed increased. To increase validity in clinical testing, it is important to consider the acceleration phase effect, especially in higher velocity isokinetic testing or for weaker muscle groups.

  4. The natural moon illusion: a multifactor angular account.

    PubMed

    Plug, C; Ross, H E

    1994-01-01

    It is argued that the failure to explain the celestial illusion results from conceptual confusion about perceived size and from disregard of the observational evidence relating to the natural moon illusion. The evidence shows that the illusion consists of a perceived angular size enlargement of horizon objects, by a factor of about 1.5-2.0 in diameter in comparison with elevated objects. Most measurements of the illusion have been made in terms of angular size, although in some proposed explanations an illusion of linear size is assumed. The magnitude of the illusion varies, particularly with the detail of the horizon scene. The illusion can be explained as the sum of several factors that affect perceived angular size: size contrast, vergence commands and eye or head position, aerial perspective, and colour. The relative contributions of these factors are assessed.

  5. Fast angular synchronization for phase retrieval via incomplete information

    NASA Astrophysics Data System (ADS)

    Viswanathan, Aditya; Iwen, Mark

    2015-08-01

    We consider the problem of recovering the phase of an unknown vector, x ∈ ℂd, given (normalized) phase difference measurements of the form xjxk*/|xjxk*|, j,k ∈ {1,...,d}, and where xj* denotes the complex conjugate of xj. This problem is sometimes referred to as the angular synchronization problem. This paper analyzes a linear-time-in-d eigenvector-based angular synchronization algorithm and studies its theoretical and numerical performance when applied to a particular class of highly incomplete and possibly noisy phase difference measurements. Theoretical results are provided for perfect (noiseless) measurements, while numerical simulations demonstrate the robustness of the method to measurement noise. Finally, we show that this angular synchronization problem and the specific form of incomplete phase difference measurements considered arise in the phase retrieval problem - where we recover an unknown complex vector from phaseless (or magnitude) measurements.

  6. Alignment of gold nanorods by angular photothermal depletion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Adam B.; Chow, Timothy T. Y.; Chon, James W. M., E-mail: jchon@swin.edu.au

    2014-02-24

    In this paper, we demonstrate that a high degree of alignment can be imposed upon randomly oriented gold nanorod films by angular photothermal depletion with linearly polarized laser irradiation. The photothermal reshaping of gold nanorods is observed to follow quadratic melting model rather than the threshold melting model, which distorts the angular and spectral hole created on 2D distribution map of nanorods to be an open crater shape. We have accounted these observations to the alignment procedures and demonstrated good agreement between experiment and simulations. The use of multiple laser depletion wavelengths allowed alignment criteria over a large range ofmore » aspect ratios, achieving 80% of the rods in the target angular range. We extend the technique to demonstrate post-alignment in a multilayer of randomly oriented gold nanorod films, with arbitrary control of alignment shown across the layers. Photothermal angular depletion alignment of gold nanorods is a simple, promising post-alignment method for creating future 3D or multilayer plasmonic nanorod based devices and structures.« less

  7. Angular momentum transport with twisted exciton wave packets

    NASA Astrophysics Data System (ADS)

    Zang, Xiaoning; Lusk, Mark T.

    2017-10-01

    A chain of cofacial molecules with CN or CN h symmetry supports excitonic states with a screwlike structure. These can be quantified with the combination of an axial wave number and an azimuthal winding number. Combinations of these states can be used to construct excitonic wave packets that spiral down the chain with well-determined linear and angular momenta. These twisted exciton wave packets can be created and annihilated using laser pulses, and their angular momentum can be optically modified during transit. This allows for the creation of optoexcitonic circuits in which information, encoded in the angular momentum of light, is converted into excitonic wave packets that can be manipulated, transported, and then reemitted. A tight-binding paradigm is used to demonstrate the key ideas. The approach is then extended to quantify the evolution of twisted exciton wave packets in a many-body, multilevel time-domain density functional theory setting. In both settings, numerical methods are developed that allow the site-to-site transfer of angular momentum to be quantified.

  8. Effect of gravity orientation on the thermal performance of Stirling-type pulse tube cryocoolers

    NASA Astrophysics Data System (ADS)

    Ross, Ronald G.; Johnson, Dean L.

    2004-06-01

    The effect of angular orientation on the off-state conduction of pulse tube cryocoolers has been previously explored, as has the effect of orientation on the thermal performance of low-frequency (˜2 Hz) GM-style pulse tube refrigerators. The significant effects that have been found are well explained by the presence of free convection that builds up in the hollow pulse tube when the hot end of the pulse tube is not higher than the cold end. This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (˜40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

  9. Rotational cavity optomechanics

    NASA Astrophysics Data System (ADS)

    Wetzel, Wyatt; Rodenburg, B.; Ek, B.; Jha, A. K.; Bhattacharya, M.

    2017-04-01

    We consider optomechanics based on the exchange of orbital angular momentum between light and matter. Specifically we consider a nanoparticle levitated in an optical ring trap in a cavity. The motion of this particle is probed by an angular lattice created by two co-propagating beams carrying equal but opposite angular momenta. Firstwe consider the case where the lattice is weak, so the nanoparticle can execute complete rotations about the cavity axis. We establishanalytically the existence of a linear regime where accurate Doppler velocimetry can be performed on the nanoparticle, and also describe numerically the dynamics in the nonlinear regime where the velocimetry is no longer accurate. Second, we consider the case where the lattice is strong and the nanoparticle executes torsional motion about the cavity axis. We find the presence of an external torque introduces an instability, but can also be used to tune continuously the linear optomechanical coupling whose strength can be measured by homodyning the cavity output field. This research was supported by the National Science Foundation (NSF) (1454931), the Office of Naval Research (N00014-14-1-0803), and the Research Corporation for Science Advancement (20966).

  10. Particle Morphology Effects on Flow Characteristics of PS304 Plasma Spray Coating Feedstock Powder Blend

    NASA Technical Reports Server (NTRS)

    Stanford, Malcolm K.; DellaCorte, Christopher; Eylon, Daniel

    2002-01-01

    The effects of BaF2-CaF 2 particle morphology on PS304 feedstock powder flow ability have been investigated. BaF2-CaF2 eutectic powders were fabricated by comminution (angular) and by gas atomization (spherical). The fluoride powders were added incrementally to the other powder constituents of the PS304 feedstock: nichrome, chromia, and silver powders. A linear relationship between flow time and concentration of BaF2-CaF2 powder was found. Flow of the powder blend with spherical BaF2-CaF2 was better than the angular BaF2-CaF2. Flow ability of the powder blend with angular fluorides decreased linearly with increasing fluoride concentration. Flow of the powder blend with spherical fluorides was independent of fluoride concentration. Results suggest that for this material blend, particle morphology plays a significant role in powder blend flow behavior, offering potential methods to improve powder flow ability and enhance the commercial potential. These findings may have applicability to other difficult-to-flow powders such as cohesive ceramics.

  11. Influence of training on the biokinematics in trotting Andalusian horses.

    PubMed

    Cano, M R; Miró, F; Diz, A M; Agüera, E; Galisteo, A M

    2000-11-01

    The aim of this study was to determine the influence of a 10-month training programme on the linear, temporal and angular characteristics of the fore and hind limbs at the trot in the Andalusian horse, using standard computer-aided videography. Sixteen male Andalusian horses were observed before and after training. Six strides were randomly selected for analysis in each horse and linear, temporal and angular parameters were calculated for fore and hind limbs. The training programme used here produced significant changes in kinematic parameters, such as shortening of stride length, and increase in swing duration and a decrease in hind limb stance percentage. No significant differences were recorded in the angular values for the forelimb joints. In trained horses, the more proximal joints of the hind limb, especially the hip and stifle, had a greater flexion while the fetlock showed a smaller extension angle. At the beginning of the swing phase, hip and stifle joints presented angles that were significantly more flexed. When the hind limbs came into contact with the ground, all the joints presented greater flexion after training.

  12. Relationship between head posture and dentofacial morphology in patients with TMJ osteoarthritis/osteoarthrosis.

    PubMed

    Ioi, Hideki; Matsumoto, Ryusuke; Nishioka, Masato; Goto, Tazuko K; Nakata, Shunsuke; Nakasima, Akihiko; Counts, Amy L

    2008-01-01

    To test whether there is a relationship between head and cervical posture and dentofacial morphology in patients with temporomandibular joint osteoarthritis/osteoarthrosis (OA). The subjects consisted of 34 Japanese females with TMJ OA (aged 24.7 +/- 6.1 years). Six craniocervical angular measurements were constructed for head posture. Two angular and 6 linear measurements were constructed for the skeletal relationship, while 1 angular and 6 linear measurements were constructed for the dental relationship. Pearson correlation coefficients were calculated between head posture and dentofacial variables. In the skeletal relationship, increased craniocervical angulations were significantly associated with a more posterior position of the maxilla, a decreased Frankfort to mandibular plane angle, decreased mandibular length, and a decreased lower facial height. In the dental relationship, increased craniocervical angulations were significantly associated with more posterior positions of the anterior teeth to the basal bone and decreased alveolar height of the anterior-posterior teeth. The hypothesis was rejected. These results suggest that an association may exist between head and cervical posture and dentofacial morphology in patients with TMJ OA.

  13. Photometric analysis of esthetically pleasant and unpleasant facial profile

    PubMed Central

    Fortes, Helena Nunes da Rocha; Guimarães, Thamirys Correia; Belo, Ivana Mara Lira; da Matta, Edgard Norões Rodrigues

    2014-01-01

    Objective To identify which linear, angular and proportionality measures could influence a profile to be considered esthetically pleasant or unpleasant, and to assess sexual dimorphism. Methods 150 standardized facial profile photographs of dental students of both sexes were obtained and printed on photographic paper. Ten plastic surgeons, ten orthodontists and ten layperson answered a questionnaire characterizing each profile as pleasant, acceptable or unpleasant. With the use of a score system, the 15 most pleasant and unpleasant profiles of each sex were selected. The photographs were scanned into AutoCAD computer software. Linear, angular and proportion measurements were obtained using the software tools. The average values between groups were compared by the Student's t-test and the Mann-Whitney test at 5%. Results The linear measures LL-S, LL-H, LL-E, LL-B and Pn-H showed statistically significant differences (p < 0.05). Statistical differences were also found in the angular measures G'.Pn.Pg', G'.Sn.Pg' and Sn.Me'.C and in the proportions G'-Sn:Sn-Me' and Sn-Gn':Gn'-C (p < 0.05). Differences between sexes were found for the linear measure Ala-Pn, angles G'-Pg'.N-Pn, Sn.Me'.C, and proportions Gn'-Sn:Sn-Me' and Ala-Pn:N'-Sn. (p < 0.05). Conclusion The anteroposterior position of the lower lip, the amount of nose that influences the profile, facial convexity, total vertical proportion and lip-chin proportion appear to influence pleasantness of facial profile. Sexual dimorphism was identified in nasal length, nasofacial and lower third of the face angles, total vertical and nasal height/length proportions. PMID:24945516

  14. Photometric analysis of esthetically pleasant and unpleasant facial profile.

    PubMed

    Fortes, Helena Nunes da Rocha; Guimarães, Thamirys Correia; Belo, Ivana Mara Lira; da Matta, Edgard Norões Rodrigues

    2014-01-01

    To identify which linear, angular and proportionality measures could influence a profile to be considered esthetically pleasant or unpleasant, and to assess sexual dimorphism. 150 standardized facial profile photographs of dental students of both sexes were obtained and printed on photographic paper. Ten plastic surgeons, ten orthodontists and ten layperson answered a questionnaire characterizing each profile as pleasant, acceptable or unpleasant. With the use of a score system, the 15 most pleasant and unpleasant profiles of each sex were selected. The photographs were scanned into AutoCAD computer software. Linear, angular and proportion measurements were obtained using the software tools. The average values between groups were compared by the Student's t-test and the Mann-Whitney test at a significance level of 5%. The linear measures LL-S, LL-H, LL-E, LL-B and Pn-H showed statistically significant differences (p < 0.05). Statistical differences were also found in the angular measures G'.Pn.Pg', G'.Sn.Pg' and Sn.Me'.C and in the proportions G'-Sn:Sn-Me' and Sn-Gn':Gn'-C (p < 0.05). Differences between sexes were found for the linear measure Ala-Pn, angles G'-Pg'.N-Pn, Sn.Me'.C, and proportions Gn'-Sn:Sn-Me' and Ala-Pn:N'-Sn. (p < 0.05). The anteroposterior position of the lower lip, the amount of nose that influences the profile, facial convexity, total vertical proportion and lip-chin proportion appear to influence pleasantness of facial profile. Sexual dimorphism was identified in nasal length, nasofacial and lower third of the face angles, total vertical and nasal height/length proportions.

  15. Experimental light scattering by small particles: first results with a novel Mueller matrix scatterometer

    NASA Astrophysics Data System (ADS)

    Penttilä, Antti; Maconi, Göran; Kassamakov, Ivan; Gritsevich, Maria; Hæggström, Edward; Muinonen, Karri

    2017-04-01

    We describe a setup for measuring the full angular Mueller matrix profile of a single mm- to µm-size sample, and verify the experimental results against a theoretical model. The scatterometer has a fixed or levitating sample, illuminated with a laser beam whose full polarization state is controlled. The scattered light is detected with a wave retarder-linear polarizer-photomultiplier tube combination that is attached to a rotational stage, to allow measuring the full angular profile, with the exception of the backscattering direction. By controlling the angle of the linear polarizers and the angle of the axis of the wave retarders before and after the scatterer we record such a combination of intensities that reconstructing the full Mueller matrix of the scatterer is possible. We have performed the first measurements of our calibration sample, a 5 mm sphere (N-BK7 glass, Edmund Optics). We verify the first measurement results by comparing the angular scattering profile against the theoretical results computed using Mie theory. The profiles recorded using the linear polarizers only agree with the theoretical predictions in all scattering angles. With the linear polarizers, we are able to construct the upper left 2×2 submatrix of the full Mueller matrix. The constructed (1,1) and (2,2) elements of the matrix are almost identical, as they should for a sphere, as well as the (1,2) and (2,1) elements. There are some discrepancies, as expected since calibration spheres are never perfect spherical shapes with completely homogeneous internal structure. Acknowledgments: The research is funded by the ERC Advanced Grant No. 320773 (SAEMPL).

  16. Remotely detected vehicle mass from engine torque-induced frame twisting

    DOE PAGES

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.; ...

    2017-06-08

    Determining the mass of a vehicle from ground-based passive sensor data is important for many traffic safety requirements. This paper presents a method for calculating the mass of a vehicle using ground-based video and acoustic measurements. By assuming that no energy is lost in the conversion, the mass of a vehicle can be calculated from the rotational energy generated by the vehicle’s engine and the linear acceleration of the vehicle over a period of time. The amount of rotational energy being output by the vehicle’s engine can be calculated from its torque and angular velocity. This model relates remotely observed,more » engine torque-induced frame twist to engine torque output using the vehicle’s suspension parameters and engine geometry. The angular velocity of the engine is extracted from the acoustic emission of the engine, and the linear acceleration of the vehicle is calculated by remotely observing the position of the vehicle over time. This method combines these three dynamic signals; engine induced-frame twist, engine angular velocity, and the vehicle’s linear acceleration, and three vehicle specific scalar parameters, into an expression that describes the mass of the vehicle. Finally, this method was tested on a semitrailer truck, and the results demonstrate a correlation of 97.7% between calculated and true vehicle mass.« less

  17. Remotely detected vehicle mass from engine torque-induced frame twisting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.

    Determining the mass of a vehicle from ground-based passive sensor data is important for many traffic safety requirements. This paper presents a method for calculating the mass of a vehicle using ground-based video and acoustic measurements. By assuming that no energy is lost in the conversion, the mass of a vehicle can be calculated from the rotational energy generated by the vehicle’s engine and the linear acceleration of the vehicle over a period of time. The amount of rotational energy being output by the vehicle’s engine can be calculated from its torque and angular velocity. This model relates remotely observed,more » engine torque-induced frame twist to engine torque output using the vehicle’s suspension parameters and engine geometry. The angular velocity of the engine is extracted from the acoustic emission of the engine, and the linear acceleration of the vehicle is calculated by remotely observing the position of the vehicle over time. This method combines these three dynamic signals; engine induced-frame twist, engine angular velocity, and the vehicle’s linear acceleration, and three vehicle specific scalar parameters, into an expression that describes the mass of the vehicle. Finally, this method was tested on a semitrailer truck, and the results demonstrate a correlation of 97.7% between calculated and true vehicle mass.« less

  18. Linear thermal circulator based on Coriolis forces.

    PubMed

    Li, Huanan; Kottos, Tsampikos

    2015-02-01

    We show that the presence of a Coriolis force in a rotating linear lattice imposes a nonreciprocal propagation of the phononic heat carriers. Using this effect we propose the concept of Coriolis linear thermal circulator which can control the circulation of a heat current. A simple model of three coupled harmonic masses on a rotating platform permits us to demonstrate giant circulating rectification effects for moderate values of the angular velocities of the platform.

  19. Modification of impulse generation during piqué turns with increased rotational demands.

    PubMed

    Zaferiou, Antonia M; Wilcox, Rand R; McNitt-Gray, Jill L

    2016-06-01

    During initiation of a piqué turn, a dancer generates impulse to achieve the desired lateral translation and whole-body rotation. The goal of this study was to determine how individuals regulate impulse generation when initiating piqué turns with increased rotational demands. Skilled dancers (n=10) performed single (∼360°) and double (∼720°) piqué turns from a stationary position. Linear and angular impulse generated by the push and turn legs were quantified using ground reaction forces and compared across turn conditions as a group and within a dancer using probability-based statistical methods. The results indicate that as the rotation demands of the piqué turn increased, the net angular impulse generated increased whereas net lateral impulse decreased. Early during turn initiation, the free moment contributed to angular impulse generation. Later during turn initiation, horizontal reaction forces were controlled to generate angular impulse. As rotational demands increased, the moment applied increased primarily from redirection of the horizontal reaction force (RFh) at the push leg and a combination of RFh magnitude and moment arm increases at the turn leg. RFh at each leg were coordinated to limit unwanted net linear impulse. Knowledge of observed subject-specific mechanisms is important to inform the design of turning performance training tools. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Angular Size Test on the Expansion of the Universe

    NASA Astrophysics Data System (ADS)

    López-Corredoira, Martín

    Assuming the standard cosmological model to be correct, the average linear size of the galaxies with the same luminosity is six times smaller at z = 3.2 than at z = 0; and their average angular size for a given luminosity is approximately proportional to z-1. Neither the hypothesis that galaxies which formed earlier have much higher densities nor their luminosity evolution, merger ratio, and massive outflows due to a quasar feedback mechanism are enough to justify such a strong size evolution. Also, at high redshift, the intrinsic ultraviolet surface brightness would be prohibitively high with this evolution, and the velocity dispersion much higher than observed. We explore here another possibility of overcoming this problem: considering different cosmological scenarios, which might make the observed angular sizes compatible with a weaker evolution. One of the explored models, a very simple phenomenological extrapolation of the linear Hubble law in a Euclidean static universe, fits quite well the angular size versus redshift dependence, also approximately proportional to z-1 with this cosmological model. There are no free parameters derived ad hoc, although the error bars allow a slight size/luminosity evolution. The supernova Ia Hubble diagram can also be explained in terms of this model without any ad-hoc-fitted parameter. NB: I do not argue here that the true universe is static. My intention is just to discuss which intellectual theoretical models fit better some data of the observational cosmology.

  1. Validity and reliability of the G-Cog device for kinematic measurements.

    PubMed

    Chiementin, X; Crequy, S; Bertucci, W

    2013-11-01

    The aim of this study was to test the validity and the reliability of the G-Cog which is a new BMX powermeter allowing for the measurements of the acceleration on X-Y-Z axis (250 Hz) at the BMX rear wheel. These measurements allow computing lateral, angular, linear acceleration, angular, linear velocity and the distance. Mechanical measurements at submaximal intensities in standardized laboratory conditions and during maximal exercises in the field conditions were performed to analyse the reliability of the G-Cog accelerometers. The performances were evaluated in comparison with an industrial accelerometer and with 2 powermeters, the SRM and PowerTap. Our results in laboratory conditions show that the G-Cog measurements have low value of variation coefficient (CV=2.35%). These results suggest that the G-cog accelerometers measurements are reproducible. The ratio limits of agreement of the rear hub angular velocity differences between the SRM and the G-Cog were 1.010 × ÷ 1.024 (95%CI=0.986-1.034) and between PowerTap and G-Cog were 0.993 × ÷ 1.019 (95%CI=0.974-1.012). In conclusion, our results suggest that the G-Cog angular velocity measurements are valid and reliable compared with SRM and PowerTap and could be used to analyse the kinematics during BMX actual conditions. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Characterization of commercial MOSFET detectors and their feasibility for in-vivo HDR brachytherapy.

    PubMed

    Phurailatpam, Reena; Upreti, Rituraj; Nojin Paul, Siji; Jamema, Swamidas V; Deshpande, Deepak D

    2016-01-01

    The present study was to investigate the use of MOSFET as an vivo dosimeter for the application of Ir-192 HDR brachytherapy treatments. MOSFET was characterized for dose linearity in the range of 50-1000 cGy, depth dose dependence from 2 to 7 cm, angular dependence. Signal fading was checked for two weeks. Dose linearity was found to be within 2% in the dose range (50-1000 cGy). The response varied within 8.07% for detector-source distance of 2-7 cm. The response of MOSFET with the epoxy side facing the source (0 degree) is the highest and the lowest response was observed at 90 and 270 degrees. Signal was stable during the study period. The detector showed high dose linearity and insignificant fading. But due to angular and depth dependence, care should be taken and corrections must be applied for clinical dosimetry. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak

    Here, we study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures aremore » implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Lastly, angular resolutions of 60–84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.« less

  4. Modelling and Closed-Loop System Identification of a Quadrotor-Based Aerial Manipulator

    NASA Astrophysics Data System (ADS)

    Dube, Chioniso; Pedro, Jimoh O.

    2018-05-01

    This paper presents the modelling and system identification of a quadrotor-based aerial manipulator. The aerial manipulator model is first derived analytically using the Newton-Euler formulation for the quadrotor and Recursive Newton-Euler formulation for the manipulator. The aerial manipulator is then simulated with the quadrotor under Proportional Derivative (PD) control, with the manipulator in motion. The simulation data is then used for system identification of the aerial manipulator. Auto Regressive with eXogenous inputs (ARX) models are obtained from the system identification for linear accelerations \\ddot{X} and \\ddot{Y} and yaw angular acceleration \\ddot{\\psi }. For linear acceleration \\ddot{Z}, and pitch and roll angular accelerations \\ddot{θ } and \\ddot{φ }, Auto Regressive Moving Average with eXogenous inputs (ARMAX) models are identified.

  5. Rim inertial measuring system

    NASA Technical Reports Server (NTRS)

    Groom, N. J.; Anderson, W. W.; Phillips, W. H. (Inventor)

    1981-01-01

    The invention includes an angular momentum control device (AMCD) having a rim and several magnetic bearing stations. The AMCD is in a strapped down position on a spacecraft. Each magnetic bearing station comprises means, including an axial position sensor, for controlling the position of the rim in the axial direction; and means, including a radial position sensor, for controlling the position of the rim in the radial direction. A first computer receives the signals from all the axial position sensors and computes the angular rates about first and second mutually perpendicular axes in the plane of the rim and computes the linear acceleration along a third axis perpendicular to the first and second axes. A second computer receives the signals from all the radial position sensors and computes the linear accelerations along the first and second axes.

  6. Preseason Strength Assessment of the Rotator Muscles and Shoulder Injury in Handball Players.

    PubMed

    Forthomme, Bénédicte; Croisier, Jean-Louis; Delvaux, François; Kaux, Jean-François; Crielaard, Jean-Michel; Gleizes-Cervera, Sophie

    2018-02-01

      Few researchers have identified intrinsic risk factors for shoulder injury in team handball players by analyzing measurements of maximal isokinetic rotator muscle strength.   To identify possible intrinsic risk factors for shoulder injury by analyzing measurements of maximal isokinetic rotator muscle strength.   Cross-sectional study.   Male team handball senior divisions (the highest level) in France and Belgium.   A total of 108 male high-level handball players (age = 24 ± 4 years, height = 189 ± 6 cm, mass = 87 ± 11 kg) were enrolled.   All players completed a preseason questionnaire and performed a bilateral isokinetic assessment of the shoulder rotator muscles. On a monthly questionnaire, players reported any shoulder injury that they sustained during the season.   On the preseason questionnaire, 51 of 108 (47%) participants reported a history of dominant-shoulder injury. A total of 106 participants completed the in-season questionnaire, with 22% (n = 23) reporting a shoulder injury on their dominant side during the subsequent season. Fourteen percent (n = 15) sustained microtraumatic injuries, and 8% (n = 8) described a traumatic injury. Backcourt players had a 3.5-times increased risk of injury during the new season compared with players in other positions. Among the isokinetic results, no risk factor for further injury was identified in handball players with microtraumatic injuries. For traumatic injuries, the concentric maximal strength developed by the internal rotators at high speed (240°/s) in the dominant shoulder was a protective factor against the risk of further injury.   These results can potentially identify intrinsic risk factors for shoulder injury and may be used to determine potential interventions for reducing this risk in handball players.

  7. Effect of eccentric isokinetic strengthening in the rehabilitation of patients with knee osteoarthritis: Isogo, a randomized trial

    PubMed Central

    2014-01-01

    Background Femorotibial knee osteoarthritis is associated with muscle weakness in the lower limbs, particularly in the quadriceps, which results in disease progression. The interest of having muscular strengthening as part of the therapeutic arsenal for the medical treatment of knee osteoarthritis is now well established. The functional disability induced by knee osteoarthritis manifests itself principally when walking, notably downhill, during which the muscles are called upon to contract eccentrically. We can therefore think that eccentric muscular strengthening could bring a functional benefit that is superior to concentric muscular strengthening. Methods/Design This is a prospective, randomized, bicenter, parallel-group, international study. Eighty patients aged from 40 to 75 years old, suffering from medical-stage knee osteoarthritis, will undertake 6 weeks of isokinetic muscular strengthening. Randomization determines the mode of muscular strengthening: either exclusively eccentric or exclusively concentric. The principal objective is to demonstrate the superiority of the improvement in the quadriceps isokinetic torque after isokinetic muscular strengthening by the eccentric mode compared to the concentric mode. The following parameters are also evaluated: the variations in the level of pain, the parameters of walking (maximum speed over 10 and 200 meters, analysis on a computerized Gaitrite™ treadmill), static equilibrium (on a FUSYO™ force platform), and the functional status of the patient using the Western Ontario and MacMaster Universities osteoarthritis index (WOMAC) questionnaire after the strengthening period and at 6 months. Discussion A better knowledge of the most effective mode of muscular strengthening is needed to optimize the functional benefits to the patients. In case of superiority in terms of efficacy of the eccentric mode, the latter could be given priority in the rehabilitation treatment of knee osteoarthritis patients. Trial registration Clinical trials.gov number: NCT01586130. PMID:24693988

  8. Dynamics of muscle strength improvement during isokinetic rehabilitation of athletes with ACL rupture and chondromalacia patellae.

    PubMed

    Desnica Bakrac, N

    2003-03-01

    To assess quantitatively dynamics and extent of the increase in muscle strength during isokinetic rehabilitation. daily measurements of muscle strength; detailed testing at the beginning and at the end of rehabilitation. Cybex Rehabilitation Center, Zagreb. 44 athletes (31 m, 13 F, age 16-35), 3 injury-defined groups: athletes with ACL rupture (non-reconstructed and reconstructed) and chondromalacia patellae. all subjects underwent isokinetic rehabilitation on Cybex Orthotron KT2 device, using individually designed protocols (extension and flexion exercises, concentric muscle contractions, 15 treatments). monitoring of daily progress on rehabilitation device and detailed testing on diagnostic device. All patients showed considerable improvement. Muscle strength improved on average 141% (SD=110) in ACL-reconstructed group, 144% (SD=130) for chondromalacia patellae group and 150% (SD=74) for ACL-non-reconstructed group, comparing to initial strength. Dynamic status tested on Cybex Otrhotron diagnostic device prior and after rehabilitation strongly correlated with final progress monitored on the rehabilitation device. Isokinetic rehabilitation is a quick and effective method in treating knee injuries in athletes. Both types of objective criteria have shown significant increase in muscle strength. The improvement of muscle strength was on the average 149% (SD=101), which is about 10% daily for 15 treatments. The greatest progress, 19% per day, occurred during first five days. The athletes were able to resume their sport activities as follows: patients from chondromalacia patellae group, and most of them from the non-reconstructed ACL group were back in competition within a month, while 75% from the ACL reconstructed group came back within 3 months, and the rest of them within 5 months.

  9. Effect of eccentric isokinetic strengthening in the rehabilitation of patients with knee osteoarthritis: Isogo, a randomized trial.

    PubMed

    Jegu, Anne-Gaëlle; Pereira, Bruno; Andant, Nicolas; Coudeyre, Emmanuel

    2014-04-02

    Femorotibial knee osteoarthritis is associated with muscle weakness in the lower limbs, particularly in the quadriceps, which results in disease progression. The interest of having muscular strengthening as part of the therapeutic arsenal for the medical treatment of knee osteoarthritis is now well established.The functional disability induced by knee osteoarthritis manifests itself principally when walking, notably downhill, during which the muscles are called upon to contract eccentrically.We can therefore think that eccentric muscular strengthening could bring a functional benefit that is superior to concentric muscular strengthening. This is a prospective, randomized, bicenter, parallel-group, international study. Eighty patients aged from 40 to 75 years old, suffering from medical-stage knee osteoarthritis, will undertake 6 weeks of isokinetic muscular strengthening. Randomization determines the mode of muscular strengthening: either exclusively eccentric or exclusively concentric.The principal objective is to demonstrate the superiority of the improvement in the quadriceps isokinetic torque after isokinetic muscular strengthening by the eccentric mode compared to the concentric mode.The following parameters are also evaluated: the variations in the level of pain, the parameters of walking (maximum speed over 10 and 200 meters, analysis on a computerized Gaitrite™ treadmill), static equilibrium (on a FUSYO™ force platform), and the functional status of the patient using the Western Ontario and MacMaster Universities osteoarthritis index (WOMAC) questionnaire after the strengthening period and at 6 months. A better knowledge of the most effective mode of muscular strengthening is needed to optimize the functional benefits to the patients. In case of superiority in terms of efficacy of the eccentric mode, the latter could be given priority in the rehabilitation treatment of knee osteoarthritis patients. Clinical trials.gov number: NCT01586130.

  10. Effects of squat lift training and free weight muscle training on maximum lifting load and isolinetic peak torque of young adults without impairments.

    PubMed

    Yeung, S S; Ng, G Y

    2000-06-01

    Manual lifting is a frequent cause of back injury, and there is no evidence as to which training mode can provide the best training effect for lifting performance and muscle force. The purpose of this study was to examine the effects of a squat lift training and a free weight muscle training program on the maximum lifting load and isokinetic peak torque in subjects without known neuromuscular or musculoskeletal impairments. Thirty-six adults (20 male, 16 female) without known neuromuscular or musculoskeletal impairments participated. The subjects' mean age was 21.25 years (SD=1.16, range=20-24). Subjects were divided into 3 groups. Subjects in group 1 (n=12) performed squat lift training. Subjects in group 2 (n=12) participated in free weight resistance training of their shoulder abductors, elbow flexors, knee extensors and trunk extensors. Subjects in group 3 (n=12) served as controls. The maximum lifting load and isokinetic peak torques of the trunk extensors, knee extensors, elbow flexors, and shoulder abductors of each subject were measured before and after the study. Training was conducted on alternate days for 4 weeks, with an initial load of 80% of each subject's maximum capacity and with the load increased by 5% weekly. All groups were comparable for all measured variables before the study. After 4 weeks, subjects in groups 1 and 2 demonstrated more improvement in maximum lifting load and isokinetic peak torque of the back extensors compared with the subjects in group 3, but the 2 training groups were not different. The findings demonstrate that both squat lift and free weight resistance training are equally effective in improving the lifting load and isokinetic back extension performance of individuals without impairments.

  11. Could the negative effects of static stretching in warm-up be restored by sport specific exercise?

    PubMed

    Bengtsson, Victor; Yu, Ji-Guo; Gilenstam, Kajsa

    2017-04-13

    Static stretching (SS) is widely used in warm-up as it is generally believed to increase mobility and reduce the risk of injury; however, SS has been shown to induce transient negative effects on subsequent muscle performance. Interestingly, recent studies have shown that sport specific exercise could restore SS-induced negative effects on certain sports, especially of explosive muscular performance. Whether sport specific exercise could restore SS-induced negative effects on isokinetic muscle performance remains unclear. The present study conducted two different warm-ups: 2-component warm-up and 3-component warm-up on 15 university students. Both protocols contained low intensity aerobic exercise and sport specific exercise, whereas the 3-component warm-up also contained SS which has been previously proven to induce negative effects on subsequent muscle performance. After the warm-ups, the subjects performed an isokinetic test on a Biodex. To make the sport specific exercise mimic the subsequent test, both included concentric isokinetic knee extension. During the tests, muscle performance of peak torque, mean power, and total work was recorded. Comparison of the measurements on each parameter between the two warm-ups was performed using paired t test. The comparisons did not reveal any significant difference in the measurement of any parameter between the two different warm-up protocols, and calculation of Cohen's revealed small effect sizes on all of the three variables. On basis of the present results and that the SS could induce transient negative effects on subsequent muscle performance, we concluded that the negative effects of the SS on the variables were restored by the isokinetic contractions.

  12. Age, weight, and the front abdominal power test as predictors of isokinetic trunk strength and work in young men and women.

    PubMed

    Cowley, Patrick M; Fitzgerald, Sharon; Sottung, Kyle; Swensen, Thomas

    2009-05-01

    First we tested the reliability of two new field tests of core stability (plank to fatigue test [PFT] and front abdominal power test [FAPT]), as well as established measures of core stability (isokinetic trunk extension and flexion strength [TES and TFS] and work [TEW and TFW]) over 3 days in 8 young men and women (24.0 +/- 3.1 years). The TES, TFS, TFW, and FAPT were highly reliable, TEW was moderately reliable, and PFT were unreliable for use during a single testing session. Next, we determined if age, weight, and the data from the reliable field test (FAPT) were predictive of TES, TEW, TFS, and TFW in 50 young men and women (19.0 +/- 1.2 years). The FAPT was the only significant predictor of TES and TEW in young women, explaining 16 and 15% of the variance in trunk performance, respectively. Weight was the only significant predictor of TFS and TFW in young women, explaining 28 and 14% of the variance in trunk performance, respectively. In young men, weight was the only significant predictor of TES, TEW, TFS, and TFW, and explained 27, 35, 42, and 33%, respectively, of the variance in trunk performance. In conclusion, the ability of weight and the FAPT to predict TES, TEW, TFS, and TFW was more frequent in young men than women. Additionally, because the FAPT requires few pieces of equipment, is fast to administer, and predicts isokinetic TES and TEW in young women, it can be used to provide a field-based estimate of isokinetic TES and TEW in women without history of back or lower-extremity injury.

  13. Asymmetries in functional hop tests, lower extremity kinematics, and isokinetic strength persist 6 to 9 months following anterior cruciate ligament reconstruction.

    PubMed

    Xergia, Sofia A; Pappas, Evangelos; Zampeli, Franceska; Georgiou, Spyros; Georgoulis, Anastasios D

    2013-03-01

    Within-subject and between-subject cross-sectional study. To investigate symmetry in hop-test performance, strength, and lower extremity kinematics 6 to 9 months following anterior cruciate ligament reconstruction (ACLR). Despite the extensive body of literature involving persons following ACLR, no study has comprehensively evaluated measures of strength, lower extremity kinematics, and functional performance of functional hop tests in this population. The subjects were 22 men (mean ± SD age, 28.8 ± 11.2 years) who had ACLR using a bone-patellar tendon-bone autograft 6 to 9 (7.01 ± 0.93) months previously and 22 healthy male controls (age, 24.8 ± 9.1 years). Participants completed a self-report questionnaire and underwent isokinetic strength testing and functional and kinematic assessment of the single-, triple-, and crossover-hop tests. Two-way analyses of variance were used to test for differences between the ACLR group and the control group, and between the 2 lower extremities of the ACLR group. Compared to the control group, the ACLR group had greater isokinetic knee extension torque deficits at all speeds (P ≤.001) and greater performance asymmetry for all 3 hop tests (P<.001). Compared to the noninvolved lower extremity, the involved lower extremity of the ACLR group exhibited less ankle dorsiflexion and knee flexion in the phases of propulsion (P ≤.014) and landing (P ≤.032). When compared to the control group, the involved lower extremity exhibited less ankle dorsiflexion in the propulsion phase (P<.001) but higher hip flexion in the landing phase (P = .014). Six to 9 months following ACLR, patients continue to demonstrate functional hop and isokinetic knee extension deficits, as well as kinematic differences, during the propulsion and landing phases of the hop tests.

  14. Comparison of knee function after antegrade and retrograde intramedullary nailing for diaphyseal femoral fractures: results of isokinetic evaluation.

    PubMed

    Daglar, Bulent; Gungor, Ertugrul; Delialioglu, Onder M; Karakus, Dilek; Ersoz, Murat; Tasbas, Bulent Adil; Bayrakci, Kenan; Gunel, Ugur

    2009-10-01

    To evaluate knee function in patients having femoral diaphyseal fractures treated with antegrade or retrograde intramedullary nail insertion. Prospective. Level I referral center. Seventy patients having 71 OTA 32 fractures were randomly allocated into 2 groups to be treated with either antegrade or retrograde intramedullary nails inserted with reaming. Antegrade nail in 41 fractures and retrograde femoral intramedullary nails in 30 fractures. Postoperative knee range of motion, Lysholm Knee Score, and isokinetic knee muscle function testing at least 6 months after documented fracture healing, minimum 1 year postoperatively. Groups had similar data with regard to demographics and injury patterns. Mean follow-up time was 44 (range: 25-80) months. Mean knee flexion angle was 132 and 134 degrees, and mean Lysholm Score was 84 and 83.1 in antegrade and retrograde groups, respectively (P = 0.893 and P = 0.701). Isokinetic evaluation revealed similar results for peak torque deficiencies at 30 and 180 degrees per second and total work deficiencies at 180 degrees per second (P > 0.05). Age affected the knee functioning as the higher the age of the patient is, the lower the Lysholm Score and knee flexion angle (r = -0.449, P = 0.0321 and r = -0.568, P = 0.001, respectively). Knee function seems to have similar clinical results after either antegrade or retrograde nail insertion for femoral diaphyseal fractures when knee range of motion, Lysholm Scores, and isokinetic knee evaluation are considered as outcome measures. With increasing patient age, a decrease in knee functioning should be anticipated in patients with femoral fractures treated with intramedullary nails regardless of technique.

  15. Fluidic angular velocity sensor

    NASA Technical Reports Server (NTRS)

    Berdahl, C. M. (Inventor)

    1986-01-01

    A fluidic sensor providing a differential pressure signal proportional to the angular velocity of a rotary input is described. In one embodiment the sensor includes a fluid pump having an impeller coupled to a rotary input. A housing forming a constricting fluid flow chamber is connected to the fluid input of the pump. The housing is provided with a fluid flow restrictive input to the flow chamber and a port communicating with the interior of the flow chamber. The differential pressure signal measured across the flow restrictive input is relatively noise free and proportional to the square of the angular velocity of the impeller. In an alternative embodiment, the flow chamber has a generally cylindrical configuration and plates having flow restrictive apertures are disposed within the chamber downstream from the housing port. In this embodiment, the differential pressure signal is found to be approximately linear with the angular velocity of the impeller.

  16. Angular Momentum Transport in Turbulent Flow between Independently Rotating Cylinders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paoletti, M. S.; Lathrop, D. P.; Institute for Physical Science and Technology, University of Maryland, College Park, Maryland 20742

    2011-01-14

    We present measurements of the angular momentum flux (torque) in Taylor-Couette flow of water between independently rotating cylinders for all regions of the ({Omega}{sub 1}, {Omega}{sub 2}) parameter space at high Reynolds numbers, where {Omega}{sub 1} ({Omega}{sub 2}) is the inner (outer) cylinder angular velocity. We find that the Rossby number Ro=({Omega}{sub 1}-{Omega}{sub 2})/{Omega}{sub 2} fully determines the state and torque G as compared to G(Ro={infinity}){identical_to}G{sub {infinity}.} The ratio G/G{sub {infinity}} is a linear function of Ro{sup -1} in four sections of the parameter space. For flows with radially increasing angular momentum, our measured torques greatly exceed those of previousmore » experiments [Ji et al., Nature (London), 444, 343 (2006)], but agree with the analysis of Richard and Zahn [Astron. Astrophys. 347, 734 (1999)].« less

  17. Measurement method for roll angular displacement with a high resolution by using diffraction gratings and a heterodyne interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Shanzhi, E-mail: shanzhit@gmail.com; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049; Wang, Zhao

    The roll angle measurement is difficult to be achieved directly using a typical commercial interferometer due to its low sensitivity in axial direction, where the axial direction is orthogonal to the plane of the roll angular displacement. A roll angle measurement method combined diffraction gratings with a laser heterodyne interferometer is discussed in this paper. The diffraction grating placed in the plane of a roll angular displacement and the interferometer arranged in the plane's orthogonal direction, constitute the measurement pattern for the roll angle with high resolution. The roll angular displacement, considered as the linear, can be tested precisely whenmore » the corresponding angle is very small. Using the proposed method, the angle roll measurement obtains the high resolution of 0.002{sup ″}. Experiment has proved its feasibility and practicability.« less

  18. Creating fractional quantum Hall states with atomic clusters using light-assisted insertion of angular momentum

    NASA Astrophysics Data System (ADS)

    Zhang, Junyi; Beugnon, Jerome; Nascimbene, Sylvain

    We describe a protocol to prepare clusters of ultracold bosonic atoms in strongly interacting states reminiscent of fractional quantum Hall states. Our scheme consists in injecting a controlled amount of angular momentum to an atomic gas using Raman transitions carrying orbital angular momentum. By injecting one unit of angular momentum per atom, one realizes a single-vortex state, which is well described by mean-field theory for large enough particle numbers. We also present schemes to realize fractional quantum Hall states, namely, the bosonic Laughlin and Moore-Read states. We investigate the requirements for adiabatic nucleation of such topological states, in particular comparing linear Landau-Zener ramps and arbitrary ramps obtained from optimized control methods. We also show that this protocol requires excellent control over the isotropic character of the trapping potential. ERC-Synergy Grant UQUAM, ANR-10-IDEX-0001-02, DIM NanoK Atocirc project.

  19. Rotating Hele-Shaw cell with a time-dependent angular velocity

    NASA Astrophysics Data System (ADS)

    Anjos, Pedro H. A.; Alvarez, Victor M. M.; Dias, Eduardo O.; Miranda, José A.

    2017-12-01

    Despite the large number of existing studies of viscous flows in rotating Hele-Shaw cells, most investigations analyze rotational motion with a constant angular velocity, under vanishing Reynolds number conditions in which inertial effects can be neglected. In this work, we examine the linear and weakly nonlinear dynamics of the interface between two immiscible fluids in a rotating Hele-Shaw cell, considering the action of a time-dependent angular velocity, and taking into account the contribution of inertia. By using a generalized Darcy's law, we derive a second-order mode-coupling equation which describes the time evolution of the interfacial perturbation amplitudes. For arbitrary values of viscosity and density ratios, and for a range of values of a rotational Reynolds number, we investigate how the time-dependent angular velocity and inertia affect the important finger competition events that traditionally arise in rotating Hele-Shaw flows.

  20. Spectral and angular characteristics of dielectric resonator metasurface at optical frequencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou, Longfang; Department of Electrical and Electronic Engineering, The University of Bristol, Bristol, BS8 1TH; López-García, Martin

    2014-11-10

    The capability of manipulating light at subwavelength scale has fostered the applications of flat metasurfaces in various fields. Compared to metallic structure, metasurfaces made of high permittivity low-loss dielectric resonators hold the promise of high efficiency by avoiding high conductive losses of metals at optical frequencies. This letter investigates the spectral and angular characteristics of a dielectric resonator metasurface composed of periodic sub-arrays of resonators with a linearly varying phase response. The far-field response of the metasurface can be decomposed into the response of a single grating element (sub-array) and the grating arrangement response. The analysis also reveals that couplingmore » between resonators has a non-negligible impact on the angular response. Over a wide wavelength range, the simulated and measured angular characteristics of the metasurface provide a definite illustration of how different grating diffraction orders can be selectively suppressed or enhanced through antenna sub-array design.« less

  1. Test-retest reliability of knee extensor rate of velocity and power development in older adults using the isotonic mode on a Biodex System 3 dynamometer.

    PubMed

    Van Driessche, Stijn; Van Roie, Evelien; Vanwanseele, Benedicte; Delecluse, Christophe

    2018-01-01

    Isotonic testing and measures of rapid power production are emerging as functionally relevant test methods for detection of muscle aging. Our objective was to assess reliability of rapid velocity and power measures in older adults using the isotonic mode of an isokinetic dynamometer. Sixty-three participants (aged 65 to 82 years) underwent a test-retest protocol with one week time interval. Isotonic knee extension tests were performed at four different loads: 0%, 25%, 50% and 75% of maximal isometric strength. Peak velocity (pV) and power (pP) were determined as the highest values of the velocity and power curve. Rate of velocity (RVD) and power development (RPD) were calculated as the linear slopes of the velocity- and power-time curve. Relative and absolute measures of test-retest reliability were analyzed using intraclass correlation coefficients (ICC), standard error of measurement (SEM) and Bland-Altman analyses. Overall, reliability was high for pV, pP, RVD and RPD at 0%, 25% and 50% load (ICC: .85 - .98, SEM: 3% - 10%). A trend for increased reliability at lower loads seemed apparent. The tests at 75% load led to range of motion failure and should be avoided. In addition, results demonstrated that caution is advised when interpreting early phase results (first 50ms). To conclude, our results support the use of the isotonic mode of an isokinetic dynamometer for testing rapid power and velocity characteristics in older adults, which is of high clinical relevance given that these muscle characteristics are emerging as the primary outcomes for preventive and rehabilitative interventions in aging research.

  2. Weekly Time Course of Neuro-Muscular Adaptation to Intensive Strength Training.

    PubMed

    Brown, Niklas; Bubeck, Dieter; Haeufle, Daniel F B; Weickenmeier, Johannes; Kuhl, Ellen; Alt, Wilfried; Schmitt, Syn

    2017-01-01

    Detailed description of the time course of muscular adaptation is rarely found in literature. Thus, models of muscular adaptation are difficult to validate since no detailed data of adaptation are available. In this article, as an initial step toward a detailed description and analysis of muscular adaptation, we provide a case report of 8 weeks of intense strength training with two active, male participants. Muscular adaptations were analyzed on a morphological level with MRI scans of the right quadriceps muscle and the calculation of muscle volume, on a voluntary strength level by isometric voluntary contractions with doublet stimulation (interpolated twitch technique) and on a non-voluntary level by resting twitch torques. Further, training volume and isokinetic power were closely monitored during the training phase. Data were analyzed weekly for 1 week prior to training, pre-training, 8 weeks of training and 2 weeks of detraining (no strength training). Results show a very individual adaptation to the intense strength training protocol. While training volume and isokinetic power increased linearly during the training phase, resting twitch parameters decreased for both participants after the first week of training and stayed below baseline until de-training. Voluntary activation level showed an increase in the first 4 weeks of training, while maximum voluntary contraction showed only little increase compared to baseline. Muscle volume increased for both subjects. Especially training status seemed to influence the acute reaction to intense strength training. Fatigue had a major influence on performance and could only be overcome by one participant. The results give a first detailed insight into muscular adaptation to intense strength training on various levels, providing a basis of data for a validation of muscle fatigue and adaptation models.

  3. Helicon modes in uniform plasmas. III. Angular momentum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stenzel, R. L.; Urrutia, J. M.

    Helicons are electromagnetic waves with helical phase fronts propagating in the whistler mode in magnetized plasmas and solids. They have similar properties to electromagnetic waves with angular momentum in free space. Helicons are circularly polarized waves carrying spin angular momentum and orbital angular momentum due to their propagation around the ambient magnetic field B{sub 0}. These properties have not been considered in the community of researchers working on helicon plasma sources, but are the topic of the present work. The present work focuses on the field topology of helicons in unbounded plasmas, not on helicon source physics. Helicons are excitedmore » in a large uniform laboratory plasma with a magnetic loop antenna whose dipole axis is aligned along or across B{sub 0}. The wave fields are measured in orthogonal planes and extended to three dimensions (3D) by interpolation. Since density and B{sub 0} are uniform, small amplitude waves from loops at different locations can be superimposed to generate complex antenna patterns. With a circular array of phase shifted loops, whistler modes with angular and axial wave propagation, i.e., helicons, are generated. Without boundaries radial propagation also arises. The azimuthal mode number m can be positive or negative while the field polarization remains right-hand circular. The conservation of energy and momentum implies that these field quantities are transferred to matter which causes damping or reflection. Wave-particle interactions with fast electrons are possible by Doppler shifted resonances. The transverse Doppler shift is demonstrated. Wave-wave interactions are also shown by showing collisions between different helicons. Whistler turbulence does not always have to be created by nonlinear wave-interactions but can also be a linear superposition of waves from random sources. In helicon collisions, the linear and/or orbital angular momenta can be canceled, which results in a great variety of field topologies. The work will be contrasted to the research on helicon plasma sources.« less

  4. Phase-space finite elements in a least-squares solution of the transport equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drumm, C.; Fan, W.; Pautz, S.

    2013-07-01

    The linear Boltzmann transport equation is solved using a least-squares finite element approximation in the space, angular and energy phase-space variables. The method is applied to both neutral particle transport and also to charged particle transport in the presence of an electric field, where the angular and energy derivative terms are handled with the energy/angular finite elements approximation, in a manner analogous to the way the spatial streaming term is handled. For multi-dimensional problems, a novel approach is used for the angular finite elements: mapping the surface of a unit sphere to a two-dimensional planar region and using a meshingmore » tool to generate a mesh. In this manner, much of the spatial finite-elements machinery can be easily adapted to handle the angular variable. The energy variable and the angular variable for one-dimensional problems make use of edge/beam elements, also building upon the spatial finite elements capabilities. The methods described here can make use of either continuous or discontinuous finite elements in space, angle and/or energy, with the use of continuous finite elements resulting in a smaller problem size and the use of discontinuous finite elements resulting in more accurate solutions for certain types of problems. The work described in this paper makes use of continuous finite elements, so that the resulting linear system is symmetric positive definite and can be solved with a highly efficient parallel preconditioned conjugate gradients algorithm. The phase-space finite elements capability has been built into the Sceptre code and applied to several test problems, including a simple one-dimensional problem with an analytic solution available, a two-dimensional problem with an isolated source term, showing how the method essentially eliminates ray effects encountered with discrete ordinates, and a simple one-dimensional charged-particle transport problem in the presence of an electric field. (authors)« less

  5. Linear force and moment equations for an annular smooth shaft seal perturbed both angularly and laterally

    NASA Technical Reports Server (NTRS)

    Fenwick, J.; Dijulio, R.; Ek, M. C.; Ehrgott, R.

    1982-01-01

    Coefficients are derived for equations expressing the lateral force and pitching moments associated with both planar translation and angular perturbations from a nominally centered rotating shaft with respect to a stationary seal. The coefficients for the lowest order and first derivative terms emerge as being significant and are of approximately the same order of magnitude as the fundamental coefficients derived by means of Black's equations. Second derivative, shear perturbation, and entrance coefficient variation effects are adjudged to be small.

  6. Dynamic behaviour analysis of an energy accumulation system comprising a composite flywheel

    NASA Astrophysics Data System (ADS)

    Portnov, G. G.; Kulakov, V. L.; Barinov, I. N.

    1994-01-01

    A simple system for energy accumulation comprising a rim and a massive shaft with elastic couplings was considered; the shaft runs in elastic damping bearings. Forced vibrations of the flywheel system induced by linear and angular eccentricities of composite rim were investigated. The effect of variation of different parameters of the system (stiffness of bearings, viscous friction coefficients of bearings, mass and moment of inertia of the shaft) on damping of radial and angular forced vibrations has been estimated.

  7. Two-axis angular effector

    DOEpatents

    Vaughn, Mark R.; Robinett, III, Rush D.; Phelan, John R.; Van Zuiden, Don M.

    1997-01-21

    A new class of coplanar two-axis angular effectors. These effectors combine a two-axis rotational joint analogous to a Cardan joint with linear actuators in a manner to produce a wider range of rotational motion about both axes defined by the joint. This new class of effectors also allows design of robotic manipulators having very high strength and efficiency. These effectors are particularly suited for remote operation in unknown surroundings, because of their extraordinary versatility. An immediate application is to the problems which arise in nuclear waste remediation.

  8. 14 CFR 29.471 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... equilibrium. For limit ground loads— (1) The limit ground loads obtained in the landing conditions in this... equilibrium with linear and angular inertia loads in a rational or conservative manner. (b) Critical centers...

  9. A Sensor-Based Method for Diagnostics of Machine Tool Linear Axes.

    PubMed

    Vogl, Gregory W; Weiss, Brian A; Donmez, M Alkan

    2015-01-01

    A linear axis is a vital subsystem of machine tools, which are vital systems within many manufacturing operations. When installed and operating within a manufacturing facility, a machine tool needs to stay in good condition for parts production. All machine tools degrade during operations, yet knowledge of that degradation is illusive; specifically, accurately detecting degradation of linear axes is a manual and time-consuming process. Thus, manufacturers need automated and efficient methods to diagnose the condition of their machine tool linear axes without disruptions to production. The Prognostics and Health Management for Smart Manufacturing Systems (PHM4SMS) project at the National Institute of Standards and Technology (NIST) developed a sensor-based method to quickly estimate the performance degradation of linear axes. The multi-sensor-based method uses data collected from a 'sensor box' to identify changes in linear and angular errors due to axis degradation; the sensor box contains inclinometers, accelerometers, and rate gyroscopes to capture this data. The sensors are expected to be cost effective with respect to savings in production losses and scrapped parts for a machine tool. Numerical simulations, based on sensor bandwidth and noise specifications, show that changes in straightness and angular errors could be known with acceptable test uncertainty ratios. If a sensor box resides on a machine tool and data is collected periodically, then the degradation of the linear axes can be determined and used for diagnostics and prognostics to help optimize maintenance, production schedules, and ultimately part quality.

  10. A Sensor-Based Method for Diagnostics of Machine Tool Linear Axes

    PubMed Central

    Vogl, Gregory W.; Weiss, Brian A.; Donmez, M. Alkan

    2017-01-01

    A linear axis is a vital subsystem of machine tools, which are vital systems within many manufacturing operations. When installed and operating within a manufacturing facility, a machine tool needs to stay in good condition for parts production. All machine tools degrade during operations, yet knowledge of that degradation is illusive; specifically, accurately detecting degradation of linear axes is a manual and time-consuming process. Thus, manufacturers need automated and efficient methods to diagnose the condition of their machine tool linear axes without disruptions to production. The Prognostics and Health Management for Smart Manufacturing Systems (PHM4SMS) project at the National Institute of Standards and Technology (NIST) developed a sensor-based method to quickly estimate the performance degradation of linear axes. The multi-sensor-based method uses data collected from a ‘sensor box’ to identify changes in linear and angular errors due to axis degradation; the sensor box contains inclinometers, accelerometers, and rate gyroscopes to capture this data. The sensors are expected to be cost effective with respect to savings in production losses and scrapped parts for a machine tool. Numerical simulations, based on sensor bandwidth and noise specifications, show that changes in straightness and angular errors could be known with acceptable test uncertainty ratios. If a sensor box resides on a machine tool and data is collected periodically, then the degradation of the linear axes can be determined and used for diagnostics and prognostics to help optimize maintenance, production schedules, and ultimately part quality. PMID:28691039

  11. Spatial orientation perception and reflexive eye movements--a perspective, an overview, and some clinical implications

    NASA Technical Reports Server (NTRS)

    Guedry, F. E.; Paloski, W. F. (Principal Investigator)

    1996-01-01

    When head motion includes a linear velocity component, eye velocity required to track an earth-fixed target depends upon: a) angular and linear head velocity, b) target distance, and c) direction of gaze relative to the motion trajectory. Recent research indicates that eye movements (LVOR), presumably otolith-mediated, partially compensate for linear velocity in small head excursions on small devices. Canal-mediated eye velocity (AVOR), otolith-mediated eye velocity (LVOR), and Ocular Torsion (OT) can be measured, one by one, on small devices. However, response dynamics that depend upon the ratio of linear to angular velocity in the motion trajectory and on subject orientation relative to the trajectory are present in a centrifuge paradigm. With this paradigm, two 3-min runs yields measures of: LVOR differentially modulated by different subject orientations in the two runs; OT dynamics in four conditions; two directions of "steady-state" OT, and two directions of AVOR. Efficient assessment of the dynamics (and of the underlying central integrative processes) may require a centrifuge radius of 1.0 meters or more. Clinical assessment of the spatial orientation system should include evaluation of central integrative processes that determine the dynamics of these responses.

  12. Hubble Space Telescope Angular Velocity Estimation During the Robotic Servicing Mission

    NASA Technical Reports Server (NTRS)

    Thienel, Julie K.; Queen, Steven Z.; VanEepoel, John M.; Sanner, Robert M.

    2005-01-01

    In 2004 NASA began investigation of a robotic servicing mission for the Hubble Space Telescope (HST). Such a mission would require estimates of the HST attitude and rates in order to achieve a capture by the proposed Hubble robotic vehicle (HRV). HRV was to be equipped with vision-based sensors, capable of estimating the relative attitude between HST and HRV. The inertial HST attitude is derived from the measured relative attitude and the HRV computed inertial attitude. However, the relative rate between HST and HRV cannot be measured directly. Therefore, the HST rate with respect to inertial space is not known. Two approaches are developed to estimate the HST rates. Both methods utilize the measured relative attitude and the HRV inertial attitude and rates. First, a non-linear estimator is developed. The nonlinear approach estimates the HST rate through an estimation of the inertial angular momentum. Second, a linearized approach is developed. The linearized approach is a pseudo-linear Kalman filter. Simulation test results for both methods are given. Even though the development began as an application for the HST robotic servicing mission, the methods presented are applicable to any rendezvous/capture mission involving a non-cooperative target spacecraft.

  13. Linear- and angular-shaped naphthodithiophenes: selective synthesis, properties, and application to organic field-effect transistors.

    PubMed

    Shinamura, Shoji; Osaka, Itaru; Miyazaki, Eigo; Nakao, Akiko; Yamagishi, Masakazu; Takeya, Jun; Takimiya, Kazuo

    2011-04-06

    A straightforward synthetic approach that exploits linear- and angular-shaped naphthodithiophenes (NDTs) being potential as new core structures for organic semiconductors is described. The newly established synthetic procedure involves two important steps; one is the chemoselective Sonogashira coupling reaction on the trifluoromethanesulfonyloxy site over the bromine site enabling selective formation of o-bromoethynylbenzene substructures on the naphthalene core, and the other is a facile ring closing reaction of fused-thiophene rings from the o-bromoethynylbenzene substructures. As a result, three isomeric NDTs, naphtho[2,3-b:6,7-b']dithiophene, naphtho[2,3-b:7,6-b']dithiophenes, and naphtho[2,1-b:6,5-b']dithiophene, are selectively synthesized. Electrochemical and optical measurements of the parent NDTs indicated that the shape of the molecules plays an important role in determining the electronic structure of the compounds; the linear-shaped NDTs formally isoelectronic with naphthacene have lower oxidation potentials and more red-shifted absorption bands than those of the angular-shaped NDTs isoelectronic with chrysene. On the contrary, the performance of the thin-film-based field-effect transistors (FETs) using the dioctyl or diphenyl derivatives were much influenced by the symmetry of the molecules; centrosymmetric derivatives tend to give higher mobility (up to 1.5 cm(2) V(-1) s(-1)) than axisymmetric ones (∼0.06 cm(2) V(-1) s(-1)), implying that the intermolecular orbital overlap in the solid state is influenced by the symmetry of the molecules. These results indicate that the present NDT cores, in particular the linear-shaped, centrosymmetric naphtho[2,3-b:6,7-b']dithiophene, are promising building blocks for the development of organic semiconducting materials. © 2011 American Chemical Society

  14. Computational simulations of hydrogen circular migration in protonated acetylene induced by circularly polarized light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Xuetao; Li, Wen; Schlegel, H. Bernhard, E-mail: hbs@chem.wayne.edu

    2016-08-28

    The hydrogens in protonated acetylene are very mobile and can easily migrate around the C{sub 2} core by moving between classical and non-classical structures of the cation. The lowest energy structure is the T-shaped, non-classical cation with a hydrogen bridging the two carbons. Conversion to the classical H{sub 2}CCH{sup +} ion requires only 4 kcal/mol. The effect of circularly polarized light on the migration of hydrogens in oriented C{sub 2}H{sub 3}{sup +} has been simulated by Born-Oppenheimer molecular dynamics. Classical trajectory calculations were carried out with the M062X/6-311+G(3df,2pd) level of theory using linearly and circularly polarized 32 cycle 7 μmmore » cosine squared pulses with peak intensity of 5.6 × 10{sup 13} W/cm{sup 2} and 3.15 × 10{sup 13} W/cm{sup 2}, respectively. These linearly and circularly polarized pulses transfer similar amounts of energy and total angular momentum to C{sub 2}H{sub 3}{sup +}. The average angular momentum vectors of the three hydrogens show opposite directions of rotation for right and left circularly polarized light, but no directional preference for linearly polarized light. This difference results in an appreciable amount of angular displacement of the three hydrogens relative to the C{sub 2} core for circularly polarized light, but only an insignificant amount for linearly polarized light. Over the course of the simulation with circularly polarized light, this corresponds to a propeller-like motion of the three hydrogens around the C{sub 2} core of protonated acetylene.« less

  15. Inter-Ethnic/Racial Facial Variations: A Systematic Review and Bayesian Meta-Analysis of Photogrammetric Studies

    PubMed Central

    Wen, Yi Feng; Wong, Hai Ming; Lin, Ruitao; Yin, Guosheng; McGrath, Colman

    2015-01-01

    Background Numerous facial photogrammetric studies have been published around the world. We aimed to critically review these studies so as to establish population norms for various angular and linear facial measurements; and to determine inter-ethnic/racial facial variations. Methods and Findings A comprehensive and systematic search of PubMed, ISI Web of Science, Embase, and Scopus was conducted to identify facial photogrammetric studies published before December, 2014. Subjects of eligible studies were either Africans, Asians or Caucasians. A Bayesian hierarchical random effects model was developed to estimate posterior means and 95% credible intervals (CrI) for each measurement by ethnicity/race. Linear contrasts were constructed to explore inter-ethnic/racial facial variations. We identified 38 eligible studies reporting 11 angular and 18 linear facial measurements. Risk of bias of the studies ranged from 0.06 to 0.66. At the significance level of 0.05, African males were found to have smaller nasofrontal angle (posterior mean difference: 8.1°, 95% CrI: 2.2°–13.5°) compared to Caucasian males and larger nasofacial angle (7.4°, 0.1°–13.2°) compared to Asian males. Nasolabial angle was more obtuse in Caucasian females than in African (17.4°, 0.2°–35.3°) and Asian (9.1°, 0.4°–17.3°) females. Additional inter-ethnic/racial variations were revealed when the level of statistical significance was set at 0.10. Conclusions A comprehensive database for angular and linear facial measurements was established from existing studies using the statistical model and inter-ethnic/racial variations of facial features were observed. The results have implications for clinical practice and highlight the need and value for high quality photogrammetric studies. PMID:26247212

  16. Inter-Ethnic/Racial Facial Variations: A Systematic Review and Bayesian Meta-Analysis of Photogrammetric Studies.

    PubMed

    Wen, Yi Feng; Wong, Hai Ming; Lin, Ruitao; Yin, Guosheng; McGrath, Colman

    2015-01-01

    Numerous facial photogrammetric studies have been published around the world. We aimed to critically review these studies so as to establish population norms for various angular and linear facial measurements; and to determine inter-ethnic/racial facial variations. A comprehensive and systematic search of PubMed, ISI Web of Science, Embase, and Scopus was conducted to identify facial photogrammetric studies published before December, 2014. Subjects of eligible studies were either Africans, Asians or Caucasians. A Bayesian hierarchical random effects model was developed to estimate posterior means and 95% credible intervals (CrI) for each measurement by ethnicity/race. Linear contrasts were constructed to explore inter-ethnic/racial facial variations. We identified 38 eligible studies reporting 11 angular and 18 linear facial measurements. Risk of bias of the studies ranged from 0.06 to 0.66. At the significance level of 0.05, African males were found to have smaller nasofrontal angle (posterior mean difference: 8.1°, 95% CrI: 2.2°-13.5°) compared to Caucasian males and larger nasofacial angle (7.4°, 0.1°-13.2°) compared to Asian males. Nasolabial angle was more obtuse in Caucasian females than in African (17.4°, 0.2°-35.3°) and Asian (9.1°, 0.4°-17.3°) females. Additional inter-ethnic/racial variations were revealed when the level of statistical significance was set at 0.10. A comprehensive database for angular and linear facial measurements was established from existing studies using the statistical model and inter-ethnic/racial variations of facial features were observed. The results have implications for clinical practice and highlight the need and value for high quality photogrammetric studies.

  17. The Advantages of Normalizing Electromyography to Ballistic Rather than Isometric or Isokinetic Tasks.

    PubMed

    Suydam, Stephen M; Manal, Kurt; Buchanan, Thomas S

    2017-07-01

    Isometric tasks have been a standard for electromyography (EMG) normalization stemming from anatomic and physiologic stability observed during contraction. Ballistic dynamic tasks have the benefit of eliciting maximum EMG signals for normalization, despite having the potential for greater signal variability. It is the purpose of this study to compare maximum voluntary isometric contraction (MVIC) to nonisometric tasks with increasing degrees of extrinsic variability, ie, joint range of motion, velocity, rate of contraction, etc., to determine if the ballistic tasks, which elicit larger peak EMG signals, are more reliable than the constrained MVIC. Fifteen subjects performed MVIC, isokinetic, maximum countermovement jump, and sprint tasks while EMG was collected from 9 muscles in the quadriceps, hamstrings, and lower leg. The results revealed the unconstrained ballistic tasks were more reliable compared to the constrained MVIC and isokinetic tasks for all triceps surae muscles. The EMG from sprinting was more reliable than the constrained cases for both the hamstrings and vasti. The most reliable EMG signals occurred when the body was permitted its natural, unconstrained motion. These results suggest that EMG is best normalized using ballistic tasks to provide the greatest within-subject reliability, which beneficially yield maximum EMG values.

  18. Intrarater reliability of the Humac NORM isokinetic dynamometer for strength measurements of the knee and shoulder muscles.

    PubMed

    Habets, Bas; Staal, J Bart; Tijssen, Marsha; van Cingel, Robert

    2018-01-10

    To determine the intrarater reliability of the Humac NORM isokinetic dynamometer for concentric and eccentric strength tests of knee and shoulder muscles. 54 participants (50% female, average age 20.9 ± 3.1 years) performed concentric and eccentric strength measures of the knee extensors and flexors, and the shoulder internal and external rotators on two different Humac NORM isokinetic dynamometers, which were situated at two different centers. The knee extensors and flexors were tested concentrically at 60° and 180°/s, and eccentrically at 60° s. Concentric strength of the shoulder internal and external rotators, and eccentric strength of the external rotators were measured at 60° and 120°/s. We calculated intraclass correlation coefficients (ICCs), standard error of measurement, standard error of measurement expressed as a %, and the smallest detectable change to determine reliability and measurement error. ICCs for the knee tests ranged from 0.74 to 0.89, whereas ICC values for the shoulder tests ranged from 0.72 to 0.94. Measurement error was highest for the concentric test of the knee extensors and lowest for the concentric test of shoulder external rotators.

  19. Construction of an isokinetic eccentric cycle ergometer for research and training.

    PubMed

    Elmer, Steven J; Martin, James C

    2013-08-01

    Eccentric cycling serves a useful exercise modality in clinical, research, and sport training settings. However, several constraints can make it difficult to use commercially available eccentric cycle ergometers. In this technical note, we describe the process by which we built an isokinetic eccentric cycle ergometer using exercise equipment modified with commonly available industrial parts. Specifically, we started with a used recumbent cycle ergometer and removed all the original parts leaving only the frame and seat. A 2.2 kW electric motor was attached to a transmission system that was then joined with the ergometer. The motor was controlled using a variable frequency drive, which allowed for control of a wide range of pedaling rates. The ergometer was also equipped with a power measurement device that quantified work, power, and pedaling rate and provided feedback to the individual performing the exercise. With these parts along with some custom fabrication, we were able to construct an isokinetic eccentric cycle ergometer suitable for research and training. This paper offers a guide for those individuals who plan to use eccentric cycle ergometry as an exercise modality and wish to construct their own ergometer.

  20. An investigation of leg and trunk strength and reaction times of hard-style martial arts practitioners.

    PubMed

    Donovan, Oliver O; Cheung, Jeanette; Catley, Maria; McGregor, Alison H; Strutton, Paul H

    2006-01-01

    The purpose of this study was to investigate trunk and knee strength in practitioners of hard-style martial arts. An additional objective was to examine reaction times in these participants by measuring simple reaction times (SRT), choice reaction times (CRT) and movement times (MT). Thirteen high-level martial artists and twelve sedentary participants were tested under isokinetic and isometric conditions on an isokinetic dynamometer. Response and movement times were also measured in response to simple and choice auditory cues. Results indicated that the martial arts group generated a greater body-weight adjusted peak torque with both legs at all speeds during isokinetic extension and flexion, and in isometric extension but not flexion. In isokinetic and isometric trunk flexion and extension, martial artists tended to have higher peak torques than controls, but they were not significantly different (p > 0.05). During the SRT and CRT tasks the martial artists were no quicker in lifting their hand off a button in response to the stimulus [reaction time (RT)] but were significantly faster in moving to press another button [movement time (MT)]. In conclusion, the results reveal that training in a martial art increases the strength of both the flexors and extensors of the leg. Furthermore, they have faster movement times to auditory stimuli. These results are consistent with the physical aspects of the martial arts. Key PointsMartial artists undertaking hard-style martial arts have greater strength in their knee flexor and extensor muscles as tested under isokinetic testing. Under isometric testing conditions they have stronger knee extensors only.The trunk musculature is generally higher under both conditions of testing in the martial artists, although not significantly.The total reaction times of the martial artists to an auditory stimulus were significantly faster than the control participants. When analysed further it was revealed that the decrease in reaction time was due to the movement time component of the total reaction time.The training involved for the practice of the hard-style martial arts increases the strength of muscles involved in kicking. This increased strength is not seen in the trunk muscles. Furthermore, martial artists have a faster response time; the cause of which appears to be only the faster movement time.

  1. An Investigation Of Leg And Trunk Strength And Reaction Times Of Hard-Style Martial Arts Practitioners

    PubMed Central

    Donovan, Oliver O; Cheung, Jeanette; Catley, Maria; McGregor, Alison H.; Strutton, Paul H.

    2006-01-01

    The purpose of this study was to investigate trunk and knee strength in practitioners of hard-style martial arts. An additional objective was to examine reaction times in these participants by measuring simple reaction times (SRT), choice reaction times (CRT) and movement times (MT). Thirteen high-level martial artists and twelve sedentary participants were tested under isokinetic and isometric conditions on an isokinetic dynamometer. Response and movement times were also measured in response to simple and choice auditory cues. Results indicated that the martial arts group generated a greater body-weight adjusted peak torque with both legs at all speeds during isokinetic extension and flexion, and in isometric extension but not flexion. In isokinetic and isometric trunk flexion and extension, martial artists tended to have higher peak torques than controls, but they were not significantly different (p > 0.05). During the SRT and CRT tasks the martial artists were no quicker in lifting their hand off a button in response to the stimulus [reaction time (RT)] but were significantly faster in moving to press another button [movement time (MT)]. In conclusion, the results reveal that training in a martial art increases the strength of both the flexors and extensors of the leg. Furthermore, they have faster movement times to auditory stimuli. These results are consistent with the physical aspects of the martial arts. Key Points Martial artists undertaking hard-style martial arts have greater strength in their knee flexor and extensor muscles as tested under isokinetic testing. Under isometric testing conditions they have stronger knee extensors only. The trunk musculature is generally higher under both conditions of testing in the martial artists, although not significantly. The total reaction times of the martial artists to an auditory stimulus were significantly faster than the control participants. When analysed further it was revealed that the decrease in reaction time was due to the movement time component of the total reaction time. The training involved for the practice of the hard-style martial arts increases the strength of muscles involved in kicking. This increased strength is not seen in the trunk muscles. Furthermore, martial artists have a faster response time; the cause of which appears to be only the faster movement time. PMID:24376366

  2. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    PubMed Central

    Nikolaidou, Maria-Elissavet; Banke, Ingo J.; Laios, Thomas; Petsogiannis, Konstantinos; Mourikis, Anastasios

    2014-01-01

    Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports. PMID:24711944

  3. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    PubMed

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  4. Visual processing of rotary motion.

    PubMed

    Werkhoven, P; Koenderink, J J

    1991-01-01

    Local descriptions of velocity fields (e.g., rotation, divergence, and deformation) contain a wealth of information for form perception and ego motion. In spite of this, human psychophysical performance in estimating these entities has not yet been thoroughly examined. In this paper, we report on the visual discrimination of rotary motion. A sequence of image frames is used to elicit an apparent rotation of an annulus, composed of dots in the frontoparallel plane, around a fixation spot at the center of the annulus. Differential angular velocity thresholds are measured as a function of the angular velocity, the diameter of the annulus, the number of dots, the display time per frame, and the number of frames. The results show a U-shaped dependence of angular velocity discrimination on spatial scale, with minimal Weber fractions of 7%. Experiments with a scatter in the distance of the individual dots to the center of rotation demonstrate that angular velocity cannot be assessed directly; perceived angular velocity depends strongly on the distance of the dots relative to the center of rotation. We suggest that the estimation of rotary motion is mediated by local estimations of linear velocity.

  5. Probing the degenerate states of V-point singularities.

    PubMed

    Ram, B S Bhargava; Sharma, Anurag; Senthilkumaran, Paramasivam

    2017-09-15

    V-points are polarization singularities in spatially varying linearly polarized optical fields and are characterized by the Poincare-Hopf index η. Each V-point singularity is a superposition of two oppositely signed orbital angular momentum states in two orthogonal spin angular momentum states. Hence, a V-point singularity has zero net angular momentum. V-points with given |η| have the same (amplitude) intensity distribution but have four degenerate polarization distributions. Each of these four degenerate states also produce identical diffraction patterns. Hence to distinguish these degenerate states experimentally, we present in this Letter a method involving a combination of polarization transformation and diffraction. This method also shows the possibility of using polarization singularities in place of phase singularities in optical communication and quantum information processing.

  6. γ-ray telescopes using conversions to e+e- pairs: event generators, angular resolution and polarimetry

    NASA Astrophysics Data System (ADS)

    Gros, P.; Bernard, D.

    2017-02-01

    We benchmark various available event generators in Geant4 and EGS5 in the light of ongoing projects for high angular-resolution pair-conversion telescopes at low energy. We compare the distributions of key kinematic variables extracted from the geometry of the three final state particles. We validate and use as reference an exact generator using the full 5D differential cross-section of the conversion process. We focus in particular on the effect of the unmeasured recoiling nucleus on the angular resolution. We show that for high resolution trackers, the choice of the generator affects the estimated resolution of the telescope. We also show that the current available generator are unable to describe accurately a linearly polarised photon source.

  7. Angularly symmetric splitting of a light beam upon reflection and refraction at an air-dielectric plane boundary.

    PubMed

    Azzam, R M A

    2015-12-01

    Conditions for achieving equal and opposite angular deflections of a light beam by reflection and refraction at an air-dielectric boundary are determined. Such angularly symmetric beam splitting (ASBS) is possible only if the angle of incidence is >60° by exactly one third of the angle of refraction. This simple law, plus Snell's law, leads to several analytical results that clarify all aspects of this phenomenon. In particular, it is shown that the intensities of the two symmetrically deflected beams can be equalized by proper choice of the prism refractive index and the azimuth of incident linearly polarized light. ASBS enables a geometrically attractive layout of optical systems that employ multiple prism beam splitters.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, K; Li, X; Liu, B

    Purpose: To accurately measure CT bow-tie profiles from various manufacturers and to provide non-proprietary information for CT system modeling. Methods: A GOS-based linear detector (0.8 mm per pixel and 51.2 cm in length) with a fast data sampling speed (0.24 ms/sample) was used to measure the relative profiles of bow-tie filters from a collection of eight CT scanners by three different vendors, GE (LS Xtra, LS VCT, Discovery HD750), Siemens (Sensation 64, Edge, Flash, Force), and Philips (iBrilliance 256). The linear detector was first calibrated for its energy response within typical CT beam quality ranges and compared with an ionmore » chamber and analytical modeling (SPECTRA and TASMIP). A geometrical calibration process was developed to determine key parameters including the distance from the focal spot to the linear detector, the angular increment of the gantry at each data sampling, the location of the central x-ray on the linear detector, and the angular response of the detector pixel. Measurements were performed under axial-scan modes for most representative bow-tie filters and kV selections from each scanner. Bow-tie profiles were determined by re-binning the measured rotational data with an angular accuracy of 0.1 degree using the calibrated geometrical parameters. Results: The linear detector demonstrated an energy response as a solid state detector, which is close to the CT imaging detector. The geometrical calibration was proven to be sufficiently accurate (< 1mm in error for distances >550 mm) and the bow-tie profiles measured from rotational mode matched closely to those from the gantry-stationary mode. Accurate profiles were determined for a total of 21 bow-tie filters and 83 filter/kV combinations from the abovementioned scanner models. Conclusion: A new improved approach of CT bow-tie measurement was proposed and accurate bow-tie profiles were provided for a broad list of CT scanner models.« less

  9. Circularly polarized light to study linear magneto-optics for ferrofluids: θ-scan technique

    NASA Astrophysics Data System (ADS)

    Meng, Xiangshen; Huang, Yan; He, Zhenghong; Lin, Yueqiang; Liu, Xiaodong; Li, Decai; Li, Jian; Qiu, Xiaoyan

    2018-06-01

    Circularly polarized light can be divided into two vertically linearly polarized light beams with  ±π/2 phase differences. In the presence of an external magnetic field, when circularly polarized light travels through a ferrofluid film, whose thickness is no more than that of λ/4 plate, magneto-optical, magnetic birefringence and dichroism effects cause the transmitted light to behave as elliptically polarized light. Using angular scan by a continuously rotating polarizer as analyzer, the angular (θ) distribution curve of relative intensity (T) corresponding to elliptically polarized light can be measured. From the T  ‑  θ curve having ellipsometry, the parameters such as the ratio of short to long axis, and angular orientation of the long axis to the vertical field direction can be obtained. Thus, magnetic birefringence and dichroism can be probed simultaneously by measuring magneto-optical, positive or negative birefringence and dichroism features from the transmission mode. The proposed method is called θ-scan technique, and can accurately determine sample stability, magnetic field direction, and cancel intrinsic light source ellipticity. This study may be helpful to further research done to ferrofluids and other similar colloidal samples with anisotropic optics.

  10. Heritability of mandibular cephalometric variables in twins with completed craniofacial growth.

    PubMed

    Šidlauskas, Mantas; Šalomskienė, Loreta; Andriuškevičiūtė, Irena; Šidlauskienė, Monika; Labanauskas, Žygimantas; Vasiliauskas, Arūnas; Kupčinskas, Limas; Juzėnas, Simonas; Šidlauskas, Antanas

    2016-10-01

    To determine genetic and environmental impact on mandibular morphology using lateral cephalometric analysis of twins with completed mandibular growth and deoxyribonucleic acid (DNA) based zygosity determination. The 39 cephalometric variables of 141 same gender adult pair of twins were analysed. Zygosity was determined using 15 specific DNA markers and cervical vertebral maturation method was used to assess completion of the mandibular growth. A genetic analysis was performed using maximum likelihood genetic structural equation modelling (GSEM). The genetic heritability estimates of angular variables describing horizontal mandibular position in relationship to cranial base and maxilla were considerably higher than in those describing vertical position. The mandibular skeletal cephalometric variables also showed high heritability estimates with angular measurements being considerably higher than linear ones. Results of this study indicate that the angular measurements representing mandibular skeletal morphology (mandibular form) have greater genetic determination than the linear measurements (mandibular size). The shape and sagittal position of the mandible is under stronger genetic control, than is its size and vertical relationship to cranial base. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. Polarization-direction correlation measurement --- Experimental test of the PDCO methods

    NASA Astrophysics Data System (ADS)

    Starosta, K.; Morek, T.; Droste, Ch.; Rohoziński, S. G.; Srebrny, J.; Bergstrem, M.; Herskind, B.

    1998-04-01

    Information about spins and parities of excited states is crucial for nuclear structure studies. In ``in-beam" gamma ray spectroscopy the directional correlation (DCO) or angular distribution measurements are widely used tools for multipolarity assignment; although, it is known that neither of these methods is sensitive to electric or magnetic character of gamma radiation. Multipolarity of gamma rays may be determined when the results of the DCO analysis are combined with the results of linear polarization measurements. The large total efficiency of modern multidetector arrays allows one to carry out coincidence measurements between the polarimeter and the remaining detectors. The aim of the present study was to test experimentally the possibility of polarization-direction correlation measurements using the EUROGAM II array. The studied nucleus was ^164Yb produced in the ^138Ba(^30Si,4n) reaction at beam energies of 150 and 155 MeV. The angular correlation, linear polarization and direction-polarization correlation were measured for the strong transitions in yrast and non yrast cascades. Application of the PDCO analysis to a transition connecting a side band with the yrast band allowed one to rule out most of the ambiguities in multipolarity assignment occuring if one used angular correlations only.

  12. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides.

    PubMed

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun

    2013-12-01

    Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.

  13. Cephalometric Evaluation of the Hyoid Bone Position in Lebanese Healthy Young Adults.

    PubMed

    Daraze, Antoine

    2018-05-01

    The objectives of this study are to assess hyoid sagittal and vertical position, and potential correlations with gender, skeletal class, and anthropometrics. Twenty-seven cephalometric linear, angular, and ratio measurements for the hyoid were recorded on lateral cephalograms obtained from 117 healthy young Lebanese adults. Anthropometric parameters including height, weight, body mass index (BMI), and neck circumference (NC) were measured. Statistically significant gender differences were demonstrated for 21 out of 27 parameters considered. All linear and two out of three angular measurements defining the vertical hyoid position were larger in males compared with females. Five linear, one angular, and two ratio measurements showed differences in the sagittal dimension. Skeletal classes did not influence the sagittal and vertical hyoid position. Anthropometric variables as height were strongly correlated to the vertical hyoid position, while weight correlated more sagittally. Cephalometric norms for hyoid position were established, sexual dimorphism and ethnic differences were demonstrated. Skeletal patterns did not influence the sagittal and vertical hyoid bone position. Anthropometric parameters, such as BMI correlated the least to both vertical and sagittal hyoid position measurements, while the impact of height and weight as separate entities made a paradigm shift providing accurate and strong correlation of the vertical hyoid position to the height, and the sagittal hyoid position to the weight of individuals. The cephalometric norms for the hyoid bone position in the Lebanese population established in the present study are of paramount clinical importance and should be considered in planning combined orthodontic and breathing disorders treatments.

  14. Lower limb strength in professional soccer players: profile, asymmetry, and training age.

    PubMed

    Fousekis, Konstantinos; Tsepis, Elias; Vagenas, George

    2010-01-01

    Kicking and cutting skills in soccer are clearly unilateral, require asymmetrical motor patterns and lead to the development of asymmetrical adaptations in the musculoskeletal function of the lower limbs. Assuming that these adaptations constitute a chronicity-dependent process, this study examined the effects of professional training age (PTA) on the composite strength profile of the knee and ankle joint in soccer players. One hundred soccer players (n=100) with short (5-7 years), intermediate (8-10 years) and long (>11 years) PTA were tested bilaterally for isokinetic concentric and eccentric strength of the knee and ankle muscles. Knee flexion-extension was tested concentrically at 60°, 180° and 300 °/sec and eccentrically at 60° and 180 °/sec. Ankle dorsal and plantar flexions were tested at 60 °/sec for both the concentric and eccentric mode of action. Bilaterally averaged muscle strength [(R+L)/2] increased significantly from short training age to intermediate and stabilized afterwards. These strength adaptations were mainly observed at the concentric function of knee extensors at 60°/sec (p = 0. 023), knee flexors at 60°/sec (p = 0.042) and 180°/sec (p = 0.036), and ankle plantar flexors at 60o/sec (p = 0.044). A linear trend of increase in isokinetic strength with PTA level was observed for the eccentric strength of knee flexors at 60°/sec (p = 0.02) and 180°/sec (p = 0.03). Directional (R/L) asymmetries decreased with PTA, with this being mainly expressed in the concentric function of knee flexors at 180°/sec (p = 0.04) and at 300 °/sec (p = 0.03). These findings confirm the hypothesis of asymmetry in the strength adaptations that take place at the knee and ankle joint of soccer players mainly along with short and intermediate PTA. Players with a longer PTA seem to adopt a more balanced use of their lower extremities to cope with previously developed musculoskeletal asymmetries and possibly reduce injury risk. This has certain implications regarding proper training and injury prevention in relation to professional experience in soccer. Key pointsMuscle strength increased from the low (5-7 years) to the intermediate professional training age (8-10 years) and stabilized thereafter.Soccer practicing and competition at the professional level induces critical strength adaptations (asymmetries) regarding the function of the knee and ankle musculature.Soccer players with long professional training age showed a tendency for lower isokinetic strength asymmetries than players with intermediate and short professional training age.

  15. Neural processing of gravity information

    NASA Technical Reports Server (NTRS)

    Schor, Robert H.

    1992-01-01

    The goal of this project was to use the linear acceleration capabilities of the NASA Vestibular Research Facility (VRF) at Ames Research Center to directly examine encoding of linear accelerations in the vestibular system of the cat. Most previous studies, including my own, have utilized tilt stimuli, which at very low frequencies (e.g., 'static tilt') can be considered a reasonably pure linear acceleration (e.g., 'down'); however, higher frequencies of tilt, necessary for understanding the dynamic processing of linear acceleration information, necessarily involves rotations which can stimulate the semicircular canals. The VRF, particularly the Long Linear Sled, has promise to provide controlled pure linear accelerations at a variety of stimulus frequencies, with no confounding angular motion.

  16. The biomechanics of concussion in unhelmeted football players in Australia: a case–control study

    PubMed Central

    McIntosh, Andrew S; Patton, Declan A; Fréchède, Bertrand; Pierré, Paul-André; Ferry, Edouard; Barthels, Tobias

    2014-01-01

    Objective Concussion is a prevalent brain injury in sport and the wider community. Despite this, little research has been conducted investigating the dynamics of impacts to the unprotected human head and injury causation in vivo, in particular the roles of linear and angular head acceleration. Setting Professional contact football in Australia. Participants Adult male professional Australian rules football players participating in 30 games randomly selected from 103 games. Cases selected based on an observable head impact, no observable symptoms (eg, loss-of-consciousness and convulsions), no on-field medical management and no injury recorded at the time. Primary and secondary outcome measures A data set for no-injury head impact cases comprising head impact locations and head impact dynamic parameters estimated through rigid body simulations using the MAthematical DYnamic MOdels (MADYMO) human facet model. This data set was compared to previously reported concussion case data. Results Qualitative analysis showed that the head was more vulnerable to lateral impacts. Logistic regression analyses of head acceleration and velocity components revealed that angular acceleration of the head in the coronal plane had the strongest association with concussion; tentative tolerance levels of 1747 rad/s2 and 2296 rad/s2 were reported for a 50% and 75% likelihood of concussion, respectively. The mean maximum resultant angular accelerations for the concussion and no-injury cases were 7951 rad/s2 (SD 3562 rad/s2) and 4300 rad/s2 (SD 3657 rad/s2), respectively. Linear acceleration is currently used in the assessment of helmets and padded headgear. The 50% and 75% likelihood of concussion values for resultant linear head acceleration in this study were 65.1 and 88.5 g, respectively. Conclusions As hypothesised by Holbourn over 70 years ago, angular acceleration plays an important role in the pathomechanics of concussion, which has major ramifications in terms of helmet design and other efforts to prevent and manage concussion. PMID:24844272

  17. Photoelectric angle converter

    NASA Astrophysics Data System (ADS)

    Podzharenko, Volodymyr A.; Kulakov, Pavlo I.

    2001-06-01

    The photo-electric angle transmitter of rotation is offered, at which the output voltage is linear function of entering magnitude. In a transmitter the linear phototransducer is used on the basis of pair photo diode -- operating amplifier, which output voltage is linear function of the area of an illuminated photosensitive stratum, and modulator of a light stream of the special shape, which ensures a linear dependence of this area from an angle of rotation. The transmitter has good frequent properties and can be used for dynamic measurements of an angular velocity and angle of rotation, in systems of exact drives and systems of autocontrol.

  18. Bilinear modeling and nonlinear estimation

    NASA Technical Reports Server (NTRS)

    Dwyer, Thomas A. W., III; Karray, Fakhreddine; Bennett, William H.

    1989-01-01

    New methods are illustrated for online nonlinear estimation applied to the lateral deflection of an elastic beam on board measurements of angular rates and angular accelerations. The development of the filter equations, together with practical issues of their numerical solution as developed from global linearization by nonlinear output injection are contrasted with the usual method of the extended Kalman filter (EKF). It is shown how nonlinear estimation due to gyroscopic coupling can be implemented as an adaptive covariance filter using off-the-shelf Kalman filter algorithms. The effect of the global linearization by nonlinear output injection is to introduce a change of coordinates in which only the process noise covariance is to be updated in online implementation. This is in contrast to the computational approach which arises in EKF methods arising by local linearization with respect to the current conditional mean. Processing refinements for nonlinear estimation based on optimal, nonlinear interpolation between observations are also highlighted. In these methods the extrapolation of the process dynamics between measurement updates is obtained by replacing a transition matrix with an operator spline that is optimized off-line from responses to selected test inputs.

  19. A quasi-linear control theory analysis of timesharing skills

    NASA Technical Reports Server (NTRS)

    Agarwal, G. C.; Gottlieb, G. L.

    1977-01-01

    The compliance of the human ankle joint is measured by applying 0 to 50 Hz band-limited gaussian random torques to the foot of a seated human subject. These torques rotate the foot in a plantar-dorsal direction about a horizontal axis at a medial moleolus of the ankle. The applied torques and the resulting angular rotation of the foot are measured, digitized and recorded for off-line processing. Using such a best-fit, second-order model, the effective moment of inertia of the ankle joint, the angular viscosity and the stiffness are calculated. The ankle joint stiffness is shown to be a linear function of the level of tonic muscle contraction, increasing at a rate of 20 to 40 Nm/rad/Kg.m. of active torque. In terms of the muscle physiology, the more muscle fibers that are active, the greater the muscle stiffness. Joint viscosity also increases with activation. Joint stiffness is also a linear function of the joint angle, increasing at a rate of about 0.7 to 1.1 Nm/rad/deg from plantar flexion to dorsiflexion rotation.

  20. The effect of complex rehabilitation training for 12 weeks on trunk muscle function and spine deformation of patients with SCI.

    PubMed

    Sung, Dong-Hun; Yoon, Seong-Deok; Park, Gi Duck

    2015-03-01

    [Purpose] It is important for patients with incomplete spinal cord injury (SCI) to strengthen their muscle strength and return to the work force one of the ultimate objectives of rehabilitation. This study reports how a single patient with SCI became stabilized in terms of abdominal muscles and back extension muscles, as well as returning the back to the neutral position from spinal deformation, as result of complex exercises performed for 12 weeks. [Subjects] The degree of damage of the subject was rated as C grade. The subject of this study had unstable posture due to paralysis in the lower extremities of the left side after removal of a malignant tumor by surgical operation, and tilting and torsion in the pelvis increased followed by increase of kyphosis in the thoracolumbar spine. The subject was more than two years since diagnosis of incomplete SCI after surgery. [Methods] Using isokinetic lumbar muscle strength measurement equipment, peak torque/weight, total work and average power in flexion and extension of the lumbar region were measured. A trunk measurement system (Formetric 4D, DIERS, Germany), which is a 3D image processing apparatus with high resolution for vertebrae, was used in order to measure 3D vertebrae and pelvis deformation as well as static balance abilities. As an exercise method, a foam roller was used to conduct fascia relaxation massage for warming-up, and postural kyphosis was changed into postural lordosis by lat pull-down using equipment, performed in 5 sets of 15 times preset at 60% intensity of 1RM 4 set of 10 crunch exercises per set using Togu's were done while sitting at the end of Balance pad, and 4 sets of 15 bridge exercises. [Results] All angular speed tests showed a gradual increase in muscle strength. Flexion and extension showed 10% and 3% improvements, respectively. The spine deformation test showed that isokinetic exercise and lat pull-down exercise for 12 weeks resulted in improved spinal shape. [Conclusion] In this study, core stability exercise for deep muscle training and lat pull-down exercise had positive effects on lower extremity muscle strength and the spinal shape of a patient with SCI.

  1. Effects of load on ground reaction force and lower limb kinematics during concentric squats.

    PubMed

    Kellis, Eleftherios; Arambatzi, Fotini; Papadopoulos, Christos

    2005-10-01

    The purpose of this study was to examine the effects of external load on vertical ground reaction force, and linear and angular kinematics, during squats. Eight males aged 22.1 +/- 0.8 years performed maximal concentric squats using loads ranging from 7 to 70% of one-repetition maximum on a force plate while linear barbell velocity and the angular kinematics of the hip, knee and ankle were recorded. Maximum, average and angle-specific values were recorded. The ground reaction force ranged from 1.67 +/- 0.20 to 3.21 +/- 0.29 times body weight and increased significantly as external load increased (P < 0.05). Bar linear velocity ranged from 0.54 +/- 0.11 to 2.50 +/- 0.50 m x s(-1) and decreased significantly with increasing external load (P < 0.05). Hip, knee and ankle angles at maximum ground reaction force were affected by external load (P < 0.05). The force-barbell velocity curves were fitted using linear models with coefficients (r2) ranging from 0.59 to 0.96. The results suggest that maximal force exertion during squat exercises is not achieved at the same position of the lower body as external load is increased. In contrast, joint velocity coordination does not change as load is increased. The force-velocity relationship was linear and independent from the set of data used for its determination.

  2. Comparison of flume and towing methods for verifying the calibration of a suspended-sediment sampler

    USGS Publications Warehouse

    Beverage, J.P.; Futrell, J.C.

    1986-01-01

    Suspended-sediment samplers must sample isokinetically (at stream velocity) in order to collect representative water samples of rivers. Each sampler solo by the Federal Interagency Sedimentation Project or by the U.S. Geological Survey Hydrologic Instrumentation Facility has been adjusted to sample isokinetically and tested in a flume to verify the calibration. The test program for a modified U.S. P-61 sampler provided an opportunity to compare flume and towing tank tests. Although the two tests yielded statistically distinct results, the difference between them was quite small. The conclusion is that verifying the calibration of any suspended-sediment sampler by either the flume or towing method should give acceptable results.

  3. Angular Motion of Projectiles with a Moving Internal Part.

    DTIC Science & Technology

    1977-02-01

    Ball Rotor T317 hellIntermal Projectile RingsM505 Fuze Quasi-linear Angular Motion N\\ ANSTRACT (-jCanhs si rveree side ff naeweemv end identify by...LIST OF FIGURES Figure Page 1. 20mm Shell T282E1 with Arming Ball Rotor .... .......... 20 2. Fast Mode Damping Rate for the 20mm T282E1...fuze has a spherical arming rotor in a cylindrical cavity with small but non-zero clearanc’es (Figure 1). The fourth sa.ell - the 8-inch T317 - showed

  4. Spin angular momentum transfer from TEM00 focused Gaussian beams to negative refractive index spherical particles

    PubMed Central

    Ambrosio, Leonardo A.; Hernández-Figueroa, Hugo E.

    2011-01-01

    We investigate optical torques over absorbent negative refractive index spherical scatterers under the influence of linear and circularly polarized TEM00 focused Gaussian beams, in the framework of the generalized Lorenz-Mie theory with the integral localized approximation. The fundamental differences between optical torques due to spin angular momentum transfer in positive and negative refractive index optical trapping are outlined, revealing the effect of the Mie scattering coefficients in one of the most fundamental properties in optical trapping systems. PMID:21833372

  5. Theoretical proposal for determining angular momentum compensation in ferrimagnets

    NASA Astrophysics Data System (ADS)

    Zhu, Zhifeng; Fong, Xuanyao; Liang, Gengchiau

    2018-05-01

    This work demonstrates that the magnetization and angular momentum compensation temperatures (TMC and TAMC) in ferrimagnets can be unambiguously determined by performing two sets of temperature-dependent current switching, with the symmetry reversals at TMC and TAMC, respectively. A theoretical model based on the modified Landau-Lifshitz-Bloch equation is developed to systematically study the spin torque effect under different temperatures, and numerical simulations are performed to corroborate our proposal. Furthermore, we demonstrate that the recently reported linear relation between TAMC and TMC can be explained using the Curie-Weiss theory.

  6. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Control of the angular distribution of the radiation emitted by phase-locked laser arrays

    NASA Astrophysics Data System (ADS)

    Kachurin, O. R.; Lebedev, F. V.; Napartovich, M. A.; Khlynov, M. E.

    1991-03-01

    A numerical investigation was made of the influence of the number and packing density of a linear array of periodically arranged coherent sources on the efficiency of redistributing the radiation power from the side lobes to the main lobe of the angular distribution of the emitted radiation by using a binary phase corrector mounted in the image-doubling plane. The results are given of experimental investigations of a new device for improving the radiation pattern of phase-locked laser arrays.

  7. cos ( 4 φ ) azimuthal anisotropy in small- x DIS dijet production beyond the leading power TMD limit

    DOE PAGES

    Dumitru, Adrian; Skokov, Vladimir

    2016-07-25

    Here we determine the first correction to the quadrupole operator in high-energy QCD beyond the transverse momentum dependent (TMD) limit of Weizsäcker-Williams and linearly polarized gluon distributions. These functions give rise to isotropic, respectively, ~cos2more » $$\\phi$$ angular distributions in deep inelastic scattering (DIS) dijet production. On the other hand, the correction produces a ~cos4$$\\phi$$ angular dependence which is suppressed by one additional power of the dijet transverse momentum scale (squared) P 2.« less

  8. Correction of eddy current distortions in high angular resolution diffusion imaging.

    PubMed

    Zhuang, Jiancheng; Lu, Zhong-Lin; Vidal, Christine Bouteiller; Damasio, Hanna

    2013-06-01

    To correct distortions caused by eddy currents induced by large diffusion gradients during high angular resolution diffusion imaging without any auxiliary reference scans. Image distortion parameters were obtained by image coregistration, performed only between diffusion-weighted images with close diffusion gradient orientations. A linear model that describes distortion parameters (translation, scale, and shear) as a function of diffusion gradient directions was numerically computed to allow individualized distortion correction for every diffusion-weighted image. The assumptions of the algorithm were successfully verified in a series of experiments on phantom and human scans. Application of the proposed algorithm in high angular resolution diffusion images markedly reduced eddy current distortions when compared to results obtained with previously published methods. The method can correct eddy current artifacts in the high angular resolution diffusion images, and it avoids the problematic procedure of cross-correlating images with significantly different contrasts resulting from very different gradient orientations or strengths. Copyright © 2012 Wiley Periodicals, Inc.

  9. Calibration of a Six-Degree-of-Freedom Acceleration Measurement Device

    DOT National Transportation Integrated Search

    1994-12-01

    This report describes the calibration of a six-degree-of-freedom acceleration measurement system designed for use in the measurement of linear and angular head accelerations of anthropomorphic dummies during crash tests. The calibration methodology, ...

  10. Large angle solid state position sensitive x-ray detector system

    DOEpatents

    Kurtz, David S.; Ruud, Clay O.

    1998-01-01

    A method and apparatus for x-ray measurement of certain properties of a solid material. In distinction to known methods and apparatus, this invention employs a specific fiber-optic bundle configuration, termed a reorganizer, itself known for other uses, for coherently transmitting visible light originating from the scintillation of diffracted x-radiation from the solid material gathered along a substantially one dimensional linear arc, to a two-dimensional photo-sensor array. The two-dimensional photodetector array, with its many closely packed light sensitive pixels, is employed to process the information contained in the diffracted radiation and present the information in the form of a conventional x-ray diffraction spectrum. By this arrangement, the angular range of the combined detector faces may be increased without loss of angular resolution. Further, the prohibitively expensive coupling together of a large number of individual linear diode photodetectors, which would be required to process signals generated by the diffracted radiation, is avoided.

  11. Kelvin-Helmholtz instability of counter-rotating discs

    NASA Astrophysics Data System (ADS)

    Quach, Dan; Dyda, Sergei; Lovelace, Richard V. E.

    2015-01-01

    Observations of galaxies and models of accreting systems point to the occurrence of counter-rotating discs where the inner part of the disc (r < r0) is corotating and the outer part is counter-rotating. This work analyses the linear stability of radially separated co- and counter-rotating thin discs. The strong instability found is the supersonic Kelvin-Helmholtz instability. The growth rates are of the order of or larger than the angular rotation rate at the interface. The instability is absent if there is no vertical dependence of the perturbation. That is, the instability is essentially three dimensional. The non-linear evolution of the instability is predicted to lead to a mixing of the two components, strong heating of the mixed gas, and vertical expansion of the gas, and annihilation of the angular momenta of the two components. As a result, the heated gas will free-fall towards the disc's centre over the surface of the inner disc.

  12. Angular scale expansion theory and the misperception of egocentric distance in locomotor space.

    PubMed

    Durgin, Frank H

    Perception is crucial for the control of action, but perception need not be scaled accurately to produce accurate actions. This paper reviews evidence for an elegant new theory of locomotor space perception that is based on the dense coding of angular declination so that action control may be guided by richer feedback. The theory accounts for why so much direct-estimation data suggests that egocentric distance is underestimated despite the fact that action measures have been interpreted as indicating accurate perception. Actions are calibrated to the perceived scale of space and thus action measures are typically unable to distinguish systematic (e.g., linearly scaled) misperception from accurate perception. Whereas subjective reports of the scaling of linear extent are difficult to evaluate in absolute terms, study of the scaling of perceived angles (which exist in a known scale, delimited by vertical and horizontal) provides new evidence regarding the perceptual scaling of locomotor space.

  13. [Dental arch form reverting by four-point method].

    PubMed

    Pan, Xiao-Gang; Qian, Yu-Fen; Weng, Si-En; Feng, Qi-Ping; Yu, Quan

    2008-04-01

    To explore a simple method of reverting individual dental arch form template for wire bending. Individual dental arch form was reverted by four-point method. By defining central point of bracket on bilateral lower second premolar and first molar, certain individual dental arch form could be generated. The arch form generating procedure was then be developed to computer software for printing arch form. Four-point method arch form was evaluated by comparing with direct model measurement on linear and angular parameters. The accuracy and reproducibility were assessed by paired t test and concordance correlation coefficient with Medcalc 9.3 software package. The arch form by four-point method was of good accuracy and reproducibility (linear concordance correlation coefficient was 0.9909 and angular concordance correlation coefficient was 0.8419). The dental arch form reverted by four-point method could reproduce the individual dental arch form.

  14. Non-contact measurement of helicopter device position in wind tunnels with the use of optical videogrammetry method

    NASA Astrophysics Data System (ADS)

    Kuruliuk, K. A.; Kulesh, V. P.

    2016-10-01

    An optical videogrammetry method using one digital camera for non-contact measurements of geometric shape parameters, position and motion of models and structural elements of aircraft in experimental aerodynamics was developed. The tests with the use of this method for measurement of six components (three linear and three angular ones) of real position of helicopter device in wind tunnel flow were conducted. The distance between camera and test object was 15 meters. It was shown in practice that, in the conditions of aerodynamic experiment instrumental measurement error (standard deviation) for angular and linear displacements of helicopter device does not exceed 0,02° and 0.3 mm, respectively. Analysis of the results shows that at the minimum rotor thrust deviations are systematic and generally are within ± 0.2 degrees. Deviations of angle values grow with the increase of rotor thrust.

  15. Aerodynamic coefficient identification package dynamic data accuracy determinations: Lessons learned

    NASA Technical Reports Server (NTRS)

    Heck, M. L.; Findlay, J. T.; Compton, H. R.

    1983-01-01

    The errors in the dynamic data output from the Aerodynamic Coefficient Identification Packages (ACIP) flown on Shuttle flights 1, 3, 4, and 5 were determined using the output from the Inertial Measurement Units (IMU). A weighted least-squares batch algorithm was empolyed. Using an averaging technique, signal detection was enhanced; this allowed improved calibration solutions. Global errors as large as 0.04 deg/sec for the ACIP gyros, 30 mg for linear accelerometers, and 0.5 deg/sec squared in the angular accelerometer channels were detected and removed with a combination is bias, scale factor, misalignment, and g-sensitive calibration constants. No attempt was made to minimize local ACIP dynamic data deviations representing sensed high-frequency vibration or instrument noise. Resulting 1sigma calibrated ACIP global accuracies were within 0.003 eg/sec, 1.0 mg, and 0.05 deg/sec squared for the gyros, linear accelerometers, and angular accelerometers, respectively.

  16. Clustering of the human skeletal muscle fibers using linear programming and angular Hilbertian metrics.

    PubMed

    Neji, Radhouène; Besbes, Ahmed; Komodakis, Nikos; Deux, Jean-François; Maatouk, Mezri; Rahmouni, Alain; Bassez, Guillaume; Fleury, Gilles; Paragios, Nikos

    2009-01-01

    In this paper, we present a manifold clustering method fo the classification of fibers obtained from diffusion tensor images (DTI) of the human skeletal muscle. Using a linear programming formulation of prototype-based clustering, we propose a novel fiber classification algorithm over manifolds that circumvents the necessity to embed the data in low dimensional spaces and determines automatically the number of clusters. Furthermore, we propose the use of angular Hilbertian metrics between multivariate normal distributions to define a family of distances between tensors that we generalize to fibers. These metrics are used to approximate the geodesic distances over the fiber manifold. We also discuss the case where only geodesic distances to a reduced set of landmark fibers are available. The experimental validation of the method is done using a manually annotated significant dataset of DTI of the calf muscle for healthy and diseased subjects.

  17. [The assessment of functional capacity in workers with the thoracic outlet syndrome. A pilot study].

    PubMed

    Capodaglio, P; Gibellini, R; Grilli, C; Bazzini, G

    1997-01-01

    Occupational specialists are well aware of the lack of objective measurements for the diagnosis and the functional evaluation of workers affected by thoracic outlet syndrome (TOS). Subjects affected by TOS refer pain, sensation of fatigue in the arm frequently aggravated by overhead work. A "stick-up" position tends to close the costoclavicular space and tense the neck and shoulder muscles to bring into play the abnormal compression mechanism that may affect the brachial plexus nerves and the subclavian vessels. In a previous study, we demonstrated the reliability of an isokinetic hand grip endurance test. In this pilot study we asked 7 industrial workers affected by TOS to perform a 30-second isokinetic endurance test for hand gripping with a Lido WorkSET dynamometer. Tests were performed in two positions (resting and "stick-up" position) before and after a 3-week intensive rehabilitation program. In addition, the subjects performed daily aerobic exercise with an arm crank ergometer. Objective indexes of posttreatment improvement were found. Subjects were able to generate higher grip forces during the isokinetic hand grip endurance test and to sustain higher mechanical workload with the arm ergometer at the same intensity level for longer duration after completion of the rehabilitation program.

  18. Velocity associated characteristics of force production in college weight lifters.

    PubMed

    Kanehisa, H; Fukunaga, T

    1999-04-01

    To determine velocity specific isokinetic forces and cross sectional areas of reciprocal muscle groups in Olympic weight lifters. The cross sectional area of the flexor or extensor muscles of the elbow or knee joint was determined by a B-mode ultrasonic apparatus in 34 college weight lifters and 31 untrained male subjects matched for age. Maximum voluntary force produced in the flexion and extension of the elbow and knee joints was measured on an isokinetic dynamometer at 60, 180, and 300 degrees/s. The average cross sectional area was 31-65% higher, and the force was 19-62% higher in weight lifters than in the untrained subjects. The ratio of force to cross sectional area was the same in both groups. The weight lifters showed a lower velocity associated decline in force than untrained subjects in the elbow and knee flexors but not in the extensors. These results indicate that for muscle contractions with velocities between 60 degrees/s and 300 degrees/s the difference in isokinetic force between weight lifters and untrained subjects can be primarily attributed to the difference in the muscle cross sectional area. However, the lower velocity associated decline in force implies that weight lifters may have a higher force per cross sectional area than untrained subjects at velocities above 300 degrees/s.

  19. ACTN3 genotype does not influence muscle power.

    PubMed

    Hanson, E D; Ludlow, A T; Sheaff, A K; Park, J; Roth, S M

    2010-11-01

    The R577X polymorphism within the ACTN3 gene has been associated with elite athletic performance, strength, power, fat free mass, and adaptations to strength training, though inconsistencies exist in the literature. The specific muscle power phenotypes most influenced by the polymorphism are uncertain. The purpose of this study was to examine the association between ACTN3 R577X genotype and muscle power phenotypes. Recreationally active young men and women (N=57) were selected to complete 2 muscle performance assessments, an isokinetic fatigue protocol at testing speeds of 180°  s (-1) and 250°  s (-1) and a 30 s Wingate test. Isokinetic torque and Wingate power significantly decreased over the duration of each test, but no differences in the rate of decline were observed among ACTN3 genotype groups. Similarly, no significant genotype differences were observed for isokinetic peak torque, Wingate absolute or relative peak power, or fatigue index. These results indicate that in recreationally active individuals the ACTN3 R577X polymorphism is not associated with muscle performance phenotypes, supporting recent findings that R577X may only be important for predicting performance in elite athletes. Our data also indicate that using this polymorphism for genetic screening in the lay population is scientifically questionable.

  20. Strength, speed and power characteristics of elite rugby league players.

    PubMed

    de Lacey, James; Brughelli, Matt E; McGuigan, Michael R; Hansen, Keir T

    2014-08-01

    The purpose of this article was to compare strength, speed, and power characteristics between playing position (forwards and backs) in elite rugby league players. A total of 39 first team players (height, 183.8 ± 5.95 cm; body mass, 100.3 ± 10.7 kg; age, 24 ± 3 years) from a National Rugby League club participated in this study. Testing included 10-, 40-m sprint times, sprint mechanics on an instrumented nonmotorized treadmill, and concentric isokinetic hip and knee extension and flexion. Backs, observed to have significantly (p ≤ 0.05) lighter body mass (effect size [ES] = 0.98), were significantly faster (10-m ES = 1.26; 40-m ES = 1.61) and produced significantly greater relative horizontal force and power (ES = 0.87 and 1.04) compared with forwards. However, no significant differences were found between forwards and backs during relative isokinetic knee extension, knee flexion, relative isokinetic hip extension, flexion, prowler sprints, sprint velocity, contact time, or flight time. The findings demonstrate that backs have similar relative strength in comparison with forwards, but run faster overground and produce significantly greater relative horizontal force and power when sprinting on a nonmotorized instrumented treadmill. Developing force and power in the horizontal direction may be beneficial for improving sprint performance in professional rugby league players.

  1. Recovery of calf muscle strength following acute achilles tendon rupture treatment: a comparison between minimally invasive surgery and conservative treatment.

    PubMed

    Metz, Roderik; van der Heijden, Geert J M G; Verleisdonk, Egbert-Jan M M; Tamminga, Rob; van der Werken, Christiaan

    2009-10-01

    The aim of this study was to measure the effect of treatment of acute Achilles tendon ruptures on calf muscle strength recovery. Eighty-three patients with acute Achilles tendon rupture were randomly allocated to either minimally invasive surgery with functional after-treatment or conservative treatment by functional bracing. Calf muscle strength using isokinetic testing was evaluated at 3 months and after 6 or more months posttreatment. To exclusively investigate the effect of treatment on outcome, the authors excluded patients with major complications from the analysis. In 31 of 39 patients in the surgical treatment group and 25 of 34 patients in the conservative treatment group, isokinetic strength tests were performed. In the analysis of differences in mean peak torque, no statistically significant differences were found between surgery and conservative treatment, except for plantar flexion strength at 90 degrees per second at the second measurement, favoring conservative treatment. After 8 to 10 months follow- up, loss of plantar flexion strength was still present in the injured leg in both treatment groups. In conclusion, isokinetic muscle strength testing did not detect a statistically significant difference between minimally invasive surgical treatment with functional after-treatment and conservative treatment by functional bracing of acute Achilles tendon ruptures.

  2. Molecular Dynamics Simulation Studies of Fracture in Two Dimensions

    DTIC Science & Technology

    1980-05-01

    reversibility of trajectories. The microscopic elastic constants, dispersion relation and phonon spectrum of the system were determined by lattice dynamics. These... linear elasticity theory of a two-dimensional crack embedded in an infinite medium. System con- sists of 436 particles arranged in a tri- angular lattice ...satisfying these demands. In evaluating the mechanical energy of his model, Griffith used a result from linear elasticity theory, namely that for any body

  3. Eigensensitivity analysis of rotating clamped uniform beams with the asymptotic numerical method

    NASA Astrophysics Data System (ADS)

    Bekhoucha, F.; Rechak, S.; Cadou, J. M.

    2016-12-01

    In this paper, free vibrations of a rotating clamped Euler-Bernoulli beams with uniform cross section are studied using continuation method, namely asymptotic numerical method. The governing equations of motion are derived using Lagrange's method. The kinetic and strain energy expression are derived from Rayleigh-Ritz method using a set of hybrid variables and based on a linear deflection assumption. The derived equations are transformed in two eigenvalue problems, where the first is a linear gyroscopic eigenvalue problem and presents the coupled lagging and stretch motions through gyroscopic terms. While the second is standard eigenvalue problem and corresponds to the flapping motion. Those two eigenvalue problems are transformed into two functionals treated by continuation method, the Asymptotic Numerical Method. New method proposed for the solution of the linear gyroscopic system based on an augmented system, which transforms the original problem to a standard form with real symmetric matrices. By using some techniques to resolve these singular problems by the continuation method, evolution curves of the natural frequencies against dimensionless angular velocity are determined. At high angular velocity, some singular points, due to the linear elastic assumption, are computed. Numerical tests of convergence are conducted and the obtained results are compared to the exact values. Results obtained by continuation are compared to those computed with discrete eigenvalue problem.

  4. ARE THERE DIFFERENCES IN STRENGTH TESTS USING ISOKINETIC DYNAMOMETRY BETWEEN FIELD AND INDOOR PROFESSIONAL SOCCER PLAYERS?

    PubMed Central

    de Aguiar Leonardi, Adriano Barros; Martinelli, Mauro Olivio; Junior, Aires Duarte

    2015-01-01

    Objective: The objective of this study was to conduct a comparative analysis on isokinetic strength assessments between field and indoor male professional soccer players and correlate the findings with the higher levels of injury risk described in the literature. Methods: We analyzed 16 field soccer players and 15 indoor soccer players. All these professionals were male. Isokinetic muscle strength assessments were made on their knees. Results: The mean weight was 81.81 kg for field soccer and 80.33 kg for indoor soccer. The right and left peak extensor torque left and right for field soccer and indoor soccer were, respectively, 302.50 and 313.31 Nm and 265.20 and 279.80 Nm, and for flexors, 178 and 184.88 Nm and 158.27 and 154 Nm. The peak torque rates according to body weight for the left and right extensors for field soccer and indoor soccer were, respectively, 3.84 and 3.7 Nm/kg and 3.32 and 3.52 Nm/kg, and for flexors, 2.17 and 2.26 Nm/kg and 1.98 and 1.93 Nm/kg. The balance relationships between flexors and extensors on the right and left sides for field soccer and indoor soccer were, respectively, 59.81 and 59.44% and 60.47% and 54.80%. The relationships for extensors between the right and left sides for field soccer and indoor soccer were, respectively, 11.44 and 9.20%, and for the flexors, 7.31 and 8.80%. Conclusions: In accordance with international parameters, comparative analysis on isokinetic strength assessments between field and indoor male professional soccer players before the season showed that there was muscle balance and low probability of injury. There were no statistically significant differences in the parameters analyzed between the players of the two types of soccer. PMID:27042649

  5. ACL deficient potential copers and non-copers reveal different isokinetic quadriceps strength profiles in the early stage after injury

    PubMed Central

    Eitzen, I; Eitzen, TJ; Holm, I; Snyder-Mackler, L; Risberg, MA

    2011-01-01

    Background Isokinetic muscle strength tests using the peak torque value is the most frequently included quadriceps muscle strength measurement for anterior cruciate ligament (ACL) injured subjects. Aims The purpose of this study was to investigate quadriceps muscle performance during the whole isokinetic curve in ACL deficient subjects classified as potential copers or non-copers, and investigate whether these curve profiles were associated with single-leg hop performance. We hypothesized that quadriceps muscle torque at other knee flexion angles than peak torque would give more information about quadriceps muscle strength deficits. Furthermore, we hypothesized that there would be significant torque differences between potential copers and non-copers, and a significant relationship between angle specific torque values and single-leg hop performance. Study Design Cross-sectional study; Level of evidence, 2 Methods Seventy-six individuals with a complete unilateral ACL rupture within the last 3 months were included. The subjects were classified into potential copers and non-copers according to the criteria from Fitzgerald et al12. Isokinetic quadriceps muscle tests were performed at 60°/sec (Biodex 6000). Mean torque values were calculated for peak torque as well as for specific knee flexion angles. The one-leg hop and the 6 meter timed hop tests were included and symmetry indices were used. Results The peak torque value did not identify the largest quadriceps muscle strength deficit. Rather, these were established at knee flexion angles of less than 40°. There were significant differences in angle specific torque values between potential copers and non-copers (p<0.05). Moderate to strong associations were disclosed between angle specific torque values and single-leg hop performance, but only for non-copers (r≥0.32– 0.58). Conclusions Angle specific quadriceps muscle torque values of less than 40° of knee flexion provide more information on the quadriceps strength deficits after ACL injury compared to the commonly used peak torque values. PMID:20110458

  6. Differences in muscle strength after ACL reconstruction do not influence cardiorespiratory responses to isometabolic exercise

    PubMed Central

    Andrade, Marília S.; Lira, Claudio A. B.; Vancini, Rodrigo L.; Nakamoto, Fernanda P.; Cohen, Moisés; Silva, Antonio C.

    2014-01-01

    Objectives To investigate whether the muscle strength decrease that follows anterior cruciate ligament (ACL) reconstruction would lead to different cardiorespiratory adjustments during dynamic exercise. Method Eighteen active male subjects were submitted to isokinetic evaluation of knee flexor and extensor muscles four months after ACL surgery. Thigh circumference was also measured and an incremental unilateral cardiopulmonary exercise test was performed separately for both involved and uninvolved lower limbs in order to compare heart rate, oxygen consumption, minute ventilation, and ventilatory pattern (breath rate, tidal volume, inspiratory time, expiratory time, tidal volume/inspiratory time) at three different workloads (moderate, anaerobic threshold, and maximal). Results There was a significant difference between isokinetic extensor peak torque measured in the involved (116.5±29.1 Nm) and uninvolved (220.8±40.4 Nm) limbs, p=0.000. Isokinetic flexor peak torque was also lower in the involved limb than in the uninvolved limb (107.8±15.4 and 132.5±26.3 Nm, p=0.004, respectively). Lower values were also found in involved thigh circumference as compared with uninvolved limb (46.9±4.3 and 48.5±3.9 cm, p=0.005, respectively). No differences were found between the lower limbs in any of the variables of the incremental cardiopulmonary tests at all exercise intensities. Conclusions Our findings indicate that, four months after ACL surgery, there is a significant deficit in isokinetic strength in the involved limb, but these differences in muscle strength requirement do not produce differences in the cardiorespiratory adjustments to exercise. Based on the hypotheses from the literature which explain the differences in the physiological responses to exercise for different muscle masses, we can deduce that, after 4 months of a rehabilitation program after an ACL reconstruction, individuals probably do not present differences in muscle oxidative and peripheral perfusion capacities that could elicit higher levels of peripheral cardiorepiratory stimulus during exercise. PMID:24838811

  7. No Differences Between Alter G-Trainer and Active and Passive Recovery Strategies on Isokinetic Strength, Systemic Oxidative Stress and Perceived Muscle Soreness After Exercise-Induced Muscle Damage.

    PubMed

    Cooke, Matthew B; Nix, Carrie M; Greenwood, Lori D; Greenwood, Mike C

    2018-03-01

    Cooke, MB, Nix, C, Greenwood, L, and Greenwood, M. No Differences Between Alter G-Trainer and Active and Passive Recovery Strategies on Isokinetic Strength, Systemic Oxidative Stress and Perceived Muscle Soreness After Exercise-Induced Muscle Damage. J Strength Cond Res 32(3): 736-747, 2018-The incidence of muscle injuries is prevalent in elite sport athletes and weekend warriors and strategies that safely and effectively hasten recovery are highly desirable. The purpose of this study was to examine the differences between 3 recovery methods after eliciting muscle damage in recreationally active men relative to maximal isokinetic contractions, perceived muscle soreness, and psychological mood states. Twenty-five recreationally active men (22.15 ± 3.53 years, 75.75 ± 11.91 kg, 180.52 ± 7.3 cm) were randomly matched by V[Combining Dot Above]O2 peak (53.86 ± 6.65 ml·kg·min) and assigned to one of 3 recovery methods: anti-gravity treadmill (G-Trainer) (N = 8), conventional treadmill (N = 8) or static stretching (N = 9). Recovery methods were performed 30 minutes, 24, 48, and 72 hours after a 45-minute downhill run. Following eccentrically biased running, no significant differences were noted in isokinetic knee flexion and extension peak torque, systemic markers of muscle damage, oxidative stress and lipid peroxidation such as serum creatine kinase (CK), superoxide dismutase (SOD), and malondialdehyde (MDA), respectively, and subjective ratings of perceived muscle soreness between recovery methods. The G-Trainer group did however display a higher mood state as indicated by the Profile of Mood State global scores at 24 hours postexercise when compared to the conventional treadmill recovery group (p = 0.035). The improved mood state after the use of the anti-gravity treadmill may provide clinical relevance to other populations.

  8. Soft tissue changes and its stability as a sequlae to mandibular advancement.

    PubMed

    Uppada, Uday Kiran; Sinha, Ramen; Reddy, D Sreenatha; Paul, Dushyanth

    2014-01-01

    To predict the changes and evaluate the stability that occurs in the soft tissues following the skeletal movement subsequent to surgical advancement of the mandible through bilateral sagittal split osteotomy and to provide the patient reliable information with regard to esthetic changes that can be expected following the treatment. Twenty adult patients diagnosed with skeletal class II malocclusion and underwent bilateral sagittal split osteotomy for mandibular advancement by a mean of 8 mm using rigid fixation were included in the study. Soft tissue changes brought about by the surgical procedure and their stability over a period of time were evaluated prospectively using 12 linear (4 vertical and 8 horizontal) and 4 angular measurements on profile cephalograms which were taken preoperatively after the pre-surgical orthodontics (T1) and postoperatively with duration of 1 month (T2) and 6 months (T3) respectively. It was observed that compared to the linear measurements, the angular measurements showed significant changes. The improvement in the esthetic outcome is a direct reflection of the angular changes whereas the linear changes played a contributing role. Following mandibular advancement surgery the profiles of the patients was perceived to have improved with reduction in the facial convexity, an increase in the lower facial height, decrease in the depth of the mentolabial sulcus and improvement in the lip competency with lengthening, straightening and thinning of the lower lip. The soft tissue response and its stability depends on the stability of the surgical procedure itself, postsurgical growth and remodeling of the hard tissues and soft tissue changes as a result of maturation and aging.

  9. Cephalometric features in isolated growth hormone deficiency.

    PubMed

    Oliveira-Neto, Luiz Alves; Melo, Mariade de Fátima B; Franco, Alexandre A; Oliveira, Alaíde H A; Souza, Anita H O; Valença, Eugênia H O; Britto, Isabela M P A; Salvatori, Roberto; Aguiar-Oliveira, Manuel H

    2011-07-01

    To analyze cephalometric features in adults with isolated growth hormone (GH) deficiency (IGHD). Nine adult IGHD individuals (7 males and 2 females; mean age, 37.8 ± 13.8 years) underwent a cross-sectional cephalometric study, including 9 linear and 5 angular measurements. Posterior facial height/anterior facial height and lower-anterior facial height/anterior facial height ratios were calculated. To pool cephalometric measurements in both genders, results were normalized by standard deviation scores (SDS), using the population means from an atlas of the normal Brazilian population. All linear measurements were reduced in IGHD subjects. Total maxillary length was the most reduced parameter (-6.5 ± 1.7), followed by a cluster of six measurements: posterior cranial base length (-4.9 ± 1.1), total mandibular length (-4.4 ± 0.7), total posterior facial height (-4.4 ± 1.1), total anterior facial height (-4.3 ± 0.9), mandibular corpus length (-4.2 ± 0.8), and anterior cranial base length (-4.1 ± 1.7). Less affected measurements were lower-anterior facial height (-2.7 ± 0.7) and mandibular ramus height (-2.5 ± 1.5). SDS angular measurements were in the normal range, except for increased gonial angle (+2.5 ± 1.1). Posterior facial height/anterior facial height and lower-anterior facial height/anterior facial height ratios were not different from those of the reference group. Congenital, untreated IGHD causes reduction of all linear measurements of craniofacial growth, particularly total maxillary length. Angular measurements and facial height ratios are less affected, suggesting that lGHD causes proportional blunting of craniofacial growth.

  10. Green-Kubo relations for the viscosity of biaxial nematic liquid crystals

    NASA Astrophysics Data System (ADS)

    Sarman, Sten

    1996-09-01

    We derive Green-Kubo relations for the viscosities of a biaxial nematic liquid crystal. In this system there are seven shear viscosities, three twist viscosities, and three cross coupling coefficients between the antisymmetric strain rate and the symmetric traceless pressure tensor. According to the Onsager reciprocity relations these couplings are equal to the cross couplings between the symmetric traceless strain rate and the antisymmetric pressure. Our method is based on a comparison of the microscopic linear response generated by the SLLOD equations of motion for planar Couette flow (so named because of their close connection to the Doll's tensor Hamiltonian) and the macroscopic linear phenomenological relations between the pressure tensor and the strain rate. In order to obtain simple Green-Kubo relations we employ an equilibrium ensemble where the angular velocities of the directors are identically zero. This is achieved by adding constraint torques to the equations for the molecular angular accelerations. One finds that all the viscosity coefficients can be expressed as linear combinations of time correlation function integrals (TCFIs). This is much simpler compared to the expressions in the conventional canonical ensemble, where the viscosities are complicated rational functions of the TCFIs. The reason for this is, that in the constrained angular velocity ensemble, the thermodynamic forces are given external parameters whereas the thermodynamic fluxes are ensemble averages of phase functions. This is not the case in the canonical ensemble. The simplest way of obtaining numerical estimates of viscosity coefficients of a particular molecular model system is to evaluate these fluctuation relations by equilibrium molecular dynamics simulations.

  11. Accuracy of Implant Position Transfer and Surface Detail Reproduction with Different Impression Materials and Techniques

    PubMed Central

    Alikhasi, Marzieh; Siadat, Hakimeh; Kharazifard, Mohammad Javad

    2015-01-01

    Objectives: The purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials. Materials and Methods: A metal model with two implants and three grooves of 0.25, 0.50 and 0.75 mm in depth on the flat superior surface of a die was fabricated. Ten regular-body polyether (PE) and 10 regular-body polyvinyl siloxane (PVS) impressions with square and conical transfer copings using open tray and closed tray techniques were made for each group. Impressions were poured with type IV stone, and linear and angular displacements of the replica heads were evaluated using a coordinate measuring machine (CMM). Also, accurate reproduction of the grooves was evaluated by a video measuring machine (VMM). These measurements were compared with the measurements calculated on the reference model that served as control, and the data were analyzed with two-way ANOVA and t-test at P= 0.05. Results: There was less linear displacement for PVS and less angular displacement for PE in closed-tray technique, and less linear displacement for PE in open tray technique (P<0.001). Also, the open tray technique showed less angular displacement with the use of PVS impression material. Detail reproduction accuracy was the same in all the groups (P>0.05). Conclusion: The open tray technique was more accurate using PE, and also both closed tray and open tray techniques had acceptable results with the use of PVS. The choice of impression material and technique made no significant difference in surface detail reproduction. PMID:27252761

  12. Quadriceps Strength in Patients With Isolated Cartilage Defects of the Knee: Results of Isokinetic Strength Measurements and Their Correlation With Clinical and Functional Results

    PubMed Central

    Hirschmüller, Anja; Andres, Tasja; Schoch, Wolfgang; Baur, Heiner; Konstantinidis, Lukas; Südkamp, Norbert P.; Niemeyer, Philipp

    2017-01-01

    Background: Recent studies have found a significant deficit of maximum quadriceps strength after autologous chondrocyte implantation (ACI) of the knee. However, it is unclear whether muscular strength deficits in patients with cartilage damage exist prior to operative treatment. Purpose: To isokinetically test maximum quadriceps muscle strength and quantify the impact of possible strength deficits on functional and clinical test results. Study Design: Cross-sectional study; Level of evidence, 3. Methods: To identify clinically relevant muscular strength deficits, 24 patients (5 females, 19 males; mean age, 34.5 years; body mass index, 25.9 kg/m2) with isolated cartilage defects (mean onset, 5.05 years; SD, 7.8 years) in the knee joint underwent isokinetic strength measurements. Maximal quadriceps strength was recorded in 3 different testing modes: pure concentric contraction (flexors and extensors alternating work; con1), concentric-eccentric (only the extensors work concentrically and eccentrically; con2), and eccentric contraction in the alternating mode (ecc). Results were compared for functional performance (single-leg hop test), pain scales (visual analog scale [VAS], numeric rating scale [NRS]), self-reported questionnaires (International Knee Documentation Committee [IKDC], Knee Injury and Osteoarthritis Outcome Scale [KOOS]), and defect size (cm2). Results: Compared with the uninjured leg, significantly lower quadriceps strength was detected in the injured leg in all isokinetic working modes (con1 difference, 27.76 N·m [SD 17.47; P = .003]; con2 difference, 21.45 N·m [SD, 18.45; P =.025]; ecc difference, 29.48 N·m [SD, 21.51; P = .001]), with the largest deficits found for eccentric muscle performance. Moderate negative correlations were observed for the subjective pain scales NRS and VAS. The results of the IKDC and KOOS questionnaires showed low, nonsignificant correlations with findings in the isokinetic measurement. Moreover, defect sizes (mean, 3.13 cm2) were of no importance regarding the prediction of the strength deficit. The quadriceps strength deficit between the injured and the uninjured leg was best predicted by the results of the single-leg hop test. Conclusion: Patients with isolated cartilage defects of the knee joint have significant deficits in quadriceps muscle strength of the injured leg compared with the uninjured leg. The single-leg hop test may be used to predict quadriceps strength deficits. Future research should address whether preoperative strength training in patients with cartilage defects of the knee could be effective and should be taken into consideration in addition to surgical treatment. PMID:28596973

  13. Reversal of orbital angular momentum arising from an extreme Doppler shift

    PubMed Central

    Toninelli, Ermes; Horsley, Simon A. R.; Hendry, Euan; Phillips, David B.; Padgett, Miles J.

    2018-01-01

    The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes “negative.” In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at ≈100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the “negative frequency” regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. PMID:29581257

  14. Saturation of the Magnetorotational Instability at Large Elssaser Number

    NASA Astrophysics Data System (ADS)

    Julien, Keith; Jamroz, Benjamin; Knobloch, Edgar

    2009-11-01

    The MRI is believed to play an important role in accretion disk physics in extracting angular momentum from the disk and allowing accretion to take place. The instability is investigated within the shearing box approximation under conditions of fundamental importance to astrophysical accretion disk theory. The shear is taken to be the dominant source of energy, but the instability itself requires the presence of a weaker vertical magnetic field. Dissipative effects are suffiently weak that the Elsasser number is large. Thus dissipative forces do not play a role in the leading order linear instability mechanism. However, they are sufficiently large to permit a nonlinear feedback mechanism whereby the turbulent stresses generated by the MRI act on and modify the local background shear in the angular velocity profile. To date this response has been omitted in shearing box simulations and is captured by a reduced pde model derived from the global MHD fluid equations using multiscale asymptotic perturbation theory. Results from simulations of the model indicate a linear phase of exponential growth followed by a nonlinear adjustment to algebraic growth and decay in the fluctuating quantities. Remarkably, the velocity and magnetic field correlations associated with these growth and decay laws conspire to achieve saturation of angular momentum transport.

  15. Experimental evaluation of a MOSFET dosimeter for proton dose measurements.

    PubMed

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-12-07

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations.

  16. Functional phases and angular momentum characteristics of Tkatchev and Kovacs.

    PubMed

    Irwin, Gareth; Exell, Timothy A; Manning, Michelle L; Kerwin, David G

    2017-03-01

    Understanding the technical requirements and underlying biomechanics of complex release and re-grasp skills on high bar allows coaches and scientists to develop safe and effective training programmes. The aim of this study was to examine the differences in the functional phases between the Tkatchev and Kovacs skills and to explain how the angular momentum demands are addressed. Images of 18 gymnasts performing 10 Tkatchevs and 8 Kovacs at the Olympic Games were recorded (50 Hz), digitised and reconstructed (3D Direct Linear Transformation). Orientation of the functional phase action, defined by the rapid flexion to extension of the shoulders and extension to flexion of the hips as the performer passed through the lower vertical, along with shoulder and hip angular kinematics, angular momentum and key release parameters (body angle, mass centre velocity and angular momentum about the mass centre and bar) were compared between skills. Expected differences in the release parameters of angle, angular momentum and velocity were observed and the specific mechanical requirement of each skill were highlighted. Whilst there were no differences in joint kinematics, hip and shoulder functional phase were significantly earlier in the circle for the Tkatchev. These findings highlight the importance of the orientation of the functional phase in the preceding giant swing and provide coaches with further understanding of the critical timing in this key phase.

  17. Determination of optimum viewing angles for the angular normalization of land surface temperature over vegetated surface.

    PubMed

    Ren, Huazhong; Yan, Guangjian; Liu, Rongyuan; Li, Zhao-Liang; Qin, Qiming; Nerry, Françoise; Liu, Qiang

    2015-03-27

    Multi-angular observation of land surface thermal radiation is considered to be a promising method of performing the angular normalization of land surface temperature (LST) retrieved from remote sensing data. This paper focuses on an investigation of the minimum requirements of viewing angles to perform such normalizations on LST. The normally kernel-driven bi-directional reflectance distribution function (BRDF) is first extended to the thermal infrared (TIR) domain as TIR-BRDF model, and its uncertainty is shown to be less than 0.3 K when used to fit the hemispheric directional thermal radiation. A local optimum three-angle combination is found and verified using the TIR-BRDF model based on two patterns: the single-point pattern and the linear-array pattern. The TIR-BRDF is applied to an airborne multi-angular dataset to retrieve LST at nadir (Te-nadir) from different viewing directions, and the results show that this model can obtain reliable Te-nadir from 3 to 4 directional observations with large angle intervals, thus corresponding to large temperature angular variations. The Te-nadir is generally larger than temperature of the slant direction, with a difference of approximately 0.5~2.0 K for vegetated pixels and up to several Kelvins for non-vegetated pixels. The findings of this paper will facilitate the future development of multi-angular thermal infrared sensors.

  18. Determination of Optimum Viewing Angles for the Angular Normalization of Land Surface Temperature over Vegetated Surface

    PubMed Central

    Ren, Huazhong; Yan, Guangjian; Liu, Rongyuan; Li, Zhao-Liang; Qin, Qiming; Nerry, Françoise; Liu, Qiang

    2015-01-01

    Multi-angular observation of land surface thermal radiation is considered to be a promising method of performing the angular normalization of land surface temperature (LST) retrieved from remote sensing data. This paper focuses on an investigation of the minimum requirements of viewing angles to perform such normalizations on LST. The normally kernel-driven bi-directional reflectance distribution function (BRDF) is first extended to the thermal infrared (TIR) domain as TIR-BRDF model, and its uncertainty is shown to be less than 0.3 K when used to fit the hemispheric directional thermal radiation. A local optimum three-angle combination is found and verified using the TIR-BRDF model based on two patterns: the single-point pattern and the linear-array pattern. The TIR-BRDF is applied to an airborne multi-angular dataset to retrieve LST at nadir (Te-nadir) from different viewing directions, and the results show that this model can obtain reliable Te-nadir from 3 to 4 directional observations with large angle intervals, thus corresponding to large temperature angular variations. The Te-nadir is generally larger than temperature of the slant direction, with a difference of approximately 0.5~2.0 K for vegetated pixels and up to several Kelvins for non-vegetated pixels. The findings of this paper will facilitate the future development of multi-angular thermal infrared sensors. PMID:25825975

  19. Hormonal responses of metoclopramide-treated subjects experiencing nausea or emesis during parabolic flight

    NASA Technical Reports Server (NTRS)

    Kohl, Randall L.

    1987-01-01

    The concentrations of adrenocorticotropic hormone (ACTH), vasopressin (AVP), epinephrine (EPI), and norepinephrine (NE) in 22 subjects administered 10 to 20 mg of metoclopramide prior to parabolic flight are measured. The effect of metoclopramide on motion sickness is examined. It is observed that metoclopramide is ineffective in the modulation of motion sickness due to stressful linear and angular acceleration and orbital flight, and it does not affect serum hormones prior to parabolic flight. It is detected that the serum level of AVP declines following emesis induced by parabolic flight and stressful angular acceleration; the serum levels of ACTH and EPI are elevated by parabolic flight and stressful angular acceleration; and serum NE is significantly elevated immediately following emesis. The possible roles of these hormones in the etiology of space motion sickness are discussed.

  20. Characterisation and comparison of event generators for pair conversion: A crucial step for future low energy gamma telescope

    NASA Astrophysics Data System (ADS)

    Gros, P.; Bernard, D.

    2017-05-01

    Gamma ray astronomy suffers from a sensitivity gap between 0.1 and 100Mev. With high angular resolution for the electrons, it will also be possible to probe the linear polarisation of the photons. An accurate simulation is necessary to correctly design and compare these detectors. We establish baseline distributions of key kinematic variables as simulated by a 5D, exact down to threshold, and polarised event generator. We compare them to simulations with the low energy electromagnetic models available in Geant4 and in EGS5. We show that different generators give a different picture of the optimal angular resolution of pair telescopes. We also show that, of all the simulations we used, only the full 5D generator describes accurately the angular asymmetry in the case of polarised photons.

  1. Becoming angular momentum density flow through nonlinear mass transfer into a gravitating spheroidal body

    NASA Astrophysics Data System (ADS)

    Krot, A. M.

    2009-04-01

    A statistical theory for a cosmological body forming based on the spheroidal body model has been proposed in the works [1]-[4]. This work studies a slowly evolving process of gravitational condensation of a spheroidal body from an infinitely distributed gas-dust substance in space. The equation for an initial evolution of mass density function of a gas-dust cloud is considered here. It is found this equation coincides completely with the analogous equation for a slowly gravitational compressed spheroidal body [5]. A conductive flow in dissipative systems was investigated by I. Prigogine in his works (see, for example, [6], [7]). As it has been found in [2], [5], there exists a conductive antidiffusion flow in a slowly compressible gravitating spheroidal body. Applying the equation of continuity to this conductive flow density we obtain a linear antidiffusion equation [5]. However, if an intensity of conductive flow density increases sharply then the linear antidiffusion equation becomes a nonlinear one. Really, it was pointed to [6] analogous linear equations of diffusion or thermal conductivity transform in nonlinear equations respectively. In this case, the equation of continuity describes a nonlinear mass flow being a source of instabilities into a gravitating spheroidal body because the gravitational compression factor G is a function of not only time but a mass density. Using integral substitution we can reduce a nonlinear antidiffusion equation to the linear antidiffusion equation relative to a new function. If the factor G can be considered as a specific angular momentum then the new function is an angular momentum density. Thus, a nonlinear momentum density flow induces a flow of angular momentum density because streamlines of moving continuous substance come close into a gravitating spheroidal body. Really, the streamline approach leads to more tight interactions of "liquid particles" that implies a superposition of their specific angular momentums. This superposition forms an antidiffusion flow of an angular momentum density into a gravitating spheroidal body. References: [1] Krot, A.M. The statistical model of gravitational interaction of particles. Achievement in Modern Radioelectronics (spec.issue"Cosmic Radiophysics", Moscow), 1996, no.8, pp. 66-81 (in Russian). [2] Krot, A.M. Statistical description of gravitational field: a new approach. Proc. SPIE's 14th Annual Intern.Symp. "AeroSense", Orlando, Florida, USA, 2000, vol.4038, pp.1318-1329. [3] Krot, A.M. The statistical model of rotating and gravitating spheroidal body with the point of view of general relativity. Proc.35th COSPAR Scientific Assembly, Paris, France, 2004, Abstract A-00162. [4] Krot, A. The statistical approach to exploring formation of Solar system. Proc.EGU General Assembly, Vienna, Austria, 2006, Geophys.Res.Abstracts, vol.8, A-00216; SRef-ID: 1607-7962/gra/. [5] Krot, A.M. A statistical approach to investigate the formation of the solar system. Chaos, Solitons and Fractals, 2008, doi:10.1016/j.chaos.2008.06.014. [6] Glansdorff, P. and Prigogine, I. Thermodynamic Theory of Structure, Stability and Fluctuations. London, 1971. [7] Nicolis, G. and Prigogine, I. Self-organization in Nonequilibrium Systems:From Dissipative Structures to Order through Fluctuation. John Willey and Sons, New York etc., 1977.

  2. The Physics of Toys.

    ERIC Educational Resources Information Center

    Levinstein, Henry

    1982-01-01

    Outlines a course in which toys are used to demonstrate physics concepts, stressing available or easily constructed toys. A recent lecture sequence included toys demonstrating equilibrium, force/torque, linear/angular momentum conservation, energy conservation/storage, flying, vibrations, programed music, and others. Illustrations of selected toys…

  3. GMTIFS: cryogenic rotary mechanisms for the GMT Integral-Field Spectrograph

    NASA Astrophysics Data System (ADS)

    Hart, John; Espeland, Brady; Bloxham, Gabe; Boz, Robert; Bundy, Dave; Davies, John; Fordham, Bart; Herald, Nick; Sharp, Rob; Vaccarella, Annino; Vest, Colin

    2016-07-01

    A representative range of the rotary mechanisms proposed for use in GMTIFS is described. All are driven by cryogenically rated stepper motors. For each mechanism, angular position is measured by means of eddy current sensors arranged to function as a resolver. These measure the linear displacement of a decentered aluminum alloy target in two orthogonal directions, from which angular position is determined as a function of the displacement ratio. Resolver function and performance is described. For each mechanism, the mechanical design is described and the adequacy of positioning repeatability assessed. Options for improvement are discussed.

  4. Spin in Compton scattering with pronounced polarization dynamics

    NASA Astrophysics Data System (ADS)

    Ahrens, Sven; Sun, Chang-Pu

    2017-12-01

    We theoretically investigate a scattering configuration in Compton scattering, in which the orientation of the electron spin is reversed and, simultaneously, the photon polarization changes from linear polarization into circular polarization. The intrinsic angular momentum of electron and photon are computed along the coincident propagation direction of the incoming and outgoing photon. We find that this intrinsic angular momentum is not conserved in the considered scattering process. We also discuss the generation of entanglement for the considered scattering setup and present an angle-dependent investigation of the corresponding differential cross section, Stokes parameters, and spin expectation.

  5. Bekenstein inequalities and nonlinear electrodynamics

    NASA Astrophysics Data System (ADS)

    Peñafiel, M. L.; Falciano, F. T.

    2017-12-01

    Bekenstein and Mayo proposed a generalized bound for the entropy, which implies some inequalities between the charge, energy, angular momentum, and size of the macroscopic system. Dain has shown that Maxwell's electrodynamics satisfies all three inequalities. We investigate the validity of these relations in the context of nonlinear electrodynamics and show that Born-Infeld electrodynamics satisfies all of them. However, contrary to the linear theory, there is no rigidity statement in Born-Infeld. We study the physical meaning and the relationship between these inequalities, and in particular, we analyze the connection between the energy-angular momentum inequality and causality.

  6. Study on the initial value for the exterior orientation of the mobile version

    NASA Astrophysics Data System (ADS)

    Yu, Zhi-jing; Li, Shi-liang

    2011-10-01

    Single mobile vision coordinate measurement system is in the measurement site using a single camera body and a notebook computer to achieve three-dimensional coordinates. To obtain more accurate approximate values of exterior orientation calculation in the follow-up is very important in the measurement process. The problem is a typical one for the space resection, and now studies on this topic have been widely conducted in research. Single-phase space resection mainly focuses on two aspects: of co-angular constraint based on the method, its representatives are camera co-angular constraint pose estimation algorithm and the cone angle law; the other is a direct linear transformation (DLT). One common drawback for both methods is that the CCD lens distortion is not considered. When the initial value was calculated with the direct linear transformation method, the distribution and abundance of control points is required relatively high, the need that control points can not be distributed in the same plane must be met, and there are at least six non- coplanar control points. However, its usefulness is limited. Initial value will directly influence the convergence and convergence speed of the ways of calculation. This paper will make the nonlinear of the total linear equations linearized by using the total linear equations containing distorted items and Taylor series expansion, calculating the initial value of the camera exterior orientation. Finally, the initial value is proved to be better through experiments.

  7. Walking Drosophila align with the e-vector of linearly polarized light through directed modulation of angular acceleration

    PubMed Central

    Velez, Mariel M.; Wernet, Mathias F.; Clark, Damon A.

    2014-01-01

    Understanding the mechanisms that link sensory stimuli to animal behavior is a central challenge in neuroscience. The quantitative description of behavioral responses to defined stimuli has led to a rich understanding of different behavioral strategies in many species. One important navigational cue perceived by many vertebrates and insects is the e-vector orientation of linearly polarized light. Drosophila manifests an innate orientation response to this cue (‘polarotaxis’), aligning its body axis with the e-vector field. We have established a population-based behavioral paradigm for the genetic dissection of neural circuits guiding polarotaxis to both celestial as well as reflected polarized stimuli. However, the behavioral mechanisms by which flies align with a linearly polarized stimulus remain unknown. Here, we present a detailed quantitative description of Drosophila polarotaxis, systematically measuring behavioral parameters that are modulated by the stimulus. We show that angular acceleration is modulated during alignment, and this single parameter may be sufficient for alignment. Furthermore, using monocular deprivation, we show that each eye is necessary for modulating turns in the ipsilateral direction. This analysis lays the foundation for understanding how neural circuits guide these important visual behaviors. PMID:24810784

  8. Development of Torsional and Linear Piezoelectrically Driven Motors

    NASA Technical Reports Server (NTRS)

    Duong, Khanh; Newton, David; Garcia, Ephrahim

    1996-01-01

    The development of rotary and linear inchworm-motors using piezoelectric actuators is presented. The motors' design has the advantage of a macro and micro stepper motor with high load and speed. The torsional design is capable of fast angular positioning with micro level accuracy. Additionally, the rotary motor, as designed, can be used as a clutch/brake mechanism. Constructed prototype motors of both types along with their characteristics are presented. The torsional motor consists of a torsional section that provides angular displacement and torque, and two alternating clamping sections which provide the holding force. The motor relies on the principal piezoelectric coupling coefficient (d33) with no torsional elements, increasing its torque capability. The linear motor consists of a longitudinal vibrator that provides displacement and load, and two alternating clamping sections which provide the holding force. This design eliminates bending moment, tension and shear applied to the actuator elements, increase its load capability and life. Innovative flexure designs have been introduced for both motor types. Critical issues that affect the design and performance of the motors are explored and discussed. Experiments are performed demonstrating the motor prototypes based on the aforementioned design considerations.

  9. The PAC-MAN model: Benchmark case for linear acoustics in computational physics

    NASA Astrophysics Data System (ADS)

    Ziegelwanger, Harald; Reiter, Paul

    2017-10-01

    Benchmark cases in the field of computational physics, on the one hand, have to contain a certain complexity to test numerical edge cases and, on the other hand, require the existence of an analytical solution, because an analytical solution allows the exact quantification of the accuracy of a numerical simulation method. This dilemma causes a need for analytical sound field formulations of complex acoustic problems. A well known example for such a benchmark case for harmonic linear acoustics is the ;Cat's Eye model;, which describes the three-dimensional sound field radiated from a sphere with a missing octant analytically. In this paper, a benchmark case for two-dimensional (2D) harmonic linear acoustic problems, viz., the ;PAC-MAN model;, is proposed. The PAC-MAN model describes the radiated and scattered sound field around an infinitely long cylinder with a cut out sector of variable angular width. While the analytical calculation of the 2D sound field allows different angular cut-out widths and arbitrarily positioned line sources, the computational cost associated with the solution of this problem is similar to a 1D problem because of a modal formulation of the sound field in the PAC-MAN model.

  10. Joint laxity and the relationship between muscle strength and functional ability in patients with osteoarthritis of the knee.

    PubMed

    van der Esch, M; Steultjens, M; Knol, D L; Dinant, H; Dekker, J

    2006-12-15

    To establish the impact of knee joint laxity on the relationship between muscle strength and functional ability in osteoarthritis (OA) of the knee. A cross-sectional study of 86 patients with OA of the knee was conducted. Tests were performed to determine varus-valgus laxity, muscle strength, and functional ability. Laxity was assessed using a device that measures the angular deviation of the knee in the frontal plane. Muscle strength was measured using a computer-driven isokinetic dynamometer. Functional ability was assessed by observation (100-meter walking test) and self report (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]). Regression analyses were performed to assess the impact of joint laxity on the relationship between muscle strength and functional ability. In regression analyses, the interaction between muscle strength and joint laxity contributed to the variance in both walking time (P = 0.002) and WOMAC score (P = 0.080). The slope of the regression lines indicated that the relationship between muscle strength and functional ability (walking time, WOMAC) was stronger in patients with high knee joint laxity. Patients with knee OA and high knee joint laxity show a stronger relationship between muscle strength and functional ability than patients with OA and low knee joint laxity. Patients with OA, high knee joint laxity, and low muscle strength are most at risk of being disabled.

  11. Impaired control of weight bearing ankle inversion in subjects with chronic ankle instability.

    PubMed

    Terrier, R; Rose-Dulcina, K; Toschi, B; Forestier, N

    2014-04-01

    Previous studies have proposed that evertor muscle weakness represents an important factor affecting chronic ankle instability. For research purposes, ankle evertor strength is assessed by means of isokinetic evaluations. However, this methodology is constraining for daily clinical use. The present study proposes to assess ankle evertor muscle weakness using a new procedure, one that is easily accessible for rehabilitation specialists. To do so, we compared weight bearing ankle inversion control between patients suffering from chronic ankle instability and healthy subjects. 12 healthy subjects and 11 patients suffering from chronic ankle instability conducted repetitions of one leg weight bearing ankle inversion on a specific ankle destabilization device equipped with a gyroscope. Ankle inversion control was performed by means of an eccentric recruitment of evertor muscles. Instructions were to perform, as slow as possible, the ankle inversion while resisting against full body weight applied on the tested ankle. Data clearly showed higher angular inversion velocity peaks in patients suffering from chronic ankle instability. This illustrates an impaired control of weight bearing ankle inversion and, by extension, an eccentric weakness of evertor muscles. The present study supports the hypothesis of a link between the decrease of ankle joint stability and evertor muscle weakness. Moreover, it appears that the new parameter is of use in a clinical setting. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Do oarsmen have asymmetries in the strength of their back and leg muscles?

    PubMed

    Parkin, S; Nowicky, A V; Rutherford, O M; McGregor, A H

    2001-07-01

    The aim of this study was to establish whether asymmetry of the strength of the leg and trunk musculature is more prominent in rowers than in controls. Nineteen oarsmen and 20 male controls matched for age, height and body mass performed a series of isokinetic and isometric strength tests on an isokinetic dynamometer. These strength tests focused on the trunk and leg muscles. Comparisons of strength were made between and within groups for right and left symmetry patterns, hamstring: quadriceps ratios, and trunk flexor and extensor ratios. The results revealed no left and right asymmetries in either the knee extensor or flexor strength parameters (including both isometric and isokinetic measures). Knee extensor strength was significantly greater in the rowing population, but knee flexor strength was similar between the two groups. No difference was seen between the groups for the hamstring: quadriceps strength ratio. In the rowing population, stroke side had no influence on leg strength. No differences were observed in the isometric strength of the trunk flexors and extensors between groups, although EMG activity was significantly higher in the rowing population. Patterns of asymmetry of muscle activity were observed between the left and right erector spinae muscles during extension, which was significantly related to rowing side (P < 0.01). These observations could be related to the high incidence of low back pain in oarsmen.

  13. Velocity associated characteristics of force production in college weight lifters

    PubMed Central

    Kanehisa, H.; Fukunaga, T.

    1999-01-01

    OBJECTIVE: To determine velocity specific isokinetic forces and cross sectional areas of reciprocal muscle groups in Olympic weight lifters. METHODS: The cross sectional area of the flexor or extensor muscles of the elbow or knee joint was determined by a B-mode ultrasonic apparatus in 34 college weight lifters and 31 untrained male subjects matched for age. Maximum voluntary force produced in the flexion and extension of the elbow and knee joints was measured on an isokinetic dynamometer at 60, 180, and 300 degrees/s. RESULTS: The average cross sectional area was 31-65% higher, and the force was 19-62% higher in weight lifters than in the untrained subjects. The ratio of force to cross sectional area was the same in both groups. The weight lifters showed a lower velocity associated decline in force than untrained subjects in the elbow and knee flexors but not in the extensors. CONCLUSIONS: These results indicate that for muscle contractions with velocities between 60 degrees/s and 300 degrees/s the difference in isokinetic force between weight lifters and untrained subjects can be primarily attributed to the difference in the muscle cross sectional area. However, the lower velocity associated decline in force implies that weight lifters may have a higher force per cross sectional area than untrained subjects at velocities above 300 degrees/s. 




 PMID:10205693

  14. The effect of open kinetic chain knee extensor resistance training at different training loads on anterior knee laxity in the uninjured.

    PubMed

    Barcellona, Massimo G; Morrissey, Matthew C

    2016-04-01

    The commonly used open kinetic chain knee extensor (OKCKE) exercise loads the sagittal restraints to knee anterior tibial translation. To investigate the effect of different loads of OKCKE resistance training on anterior knee laxity (AKL) in the uninjured knee. non-clinical trial. Randomization into one of three supervised training groups occurred with training 3 times per week for 12 weeks. Subjects in the LOW and HIGH groups performed OKCKE resistance training at loads of 2 sets of 20 repetition maximum (RM) and 20 sets of 2RM, respectively. Subjects in the isokinetic training group (ISOK) performed isokinetic OKCKE resistance training using 2 sets of 20 maximal efforts. AKL was measured using the KT2000 arthrometer with concurrent measurement of lateral hamstrings muscle activity at baseline, 6 weeks and 12 weeks. Twenty six subjects participated (LOW n = 9, HIGH n = 10, ISOK n = 7). The main finding from this study is that a 12-week OKCKE resistance training programme at loads of 20 sets of 2RM, leads to an increase in manual maximal AKL. OKCKE resistance training at high loads (20 sets of 2RM) increases AKL while low load OKCKE resistance training (2 sets of 20RM) and isokinetic OKCKE resistance training at 2 sets of 20RM does not. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Isokinetic Dynamometry in Healthy Versus Sarcopenic and Malnourished Elderly: Beyond Simple Measurements of Muscle Strength.

    PubMed

    Cramer, Joel T; Jenkins, Nathaniel D M; Mustad, Vikkie A; Weir, Joseph P

    2017-06-01

    This study quantified systematic and intraindividual variability among three repetitions of concentric isokinetic knee extension and flexion tests to determine velocity-related differences in peak torque (PT) and mean power (MP) in healthy elderly (HE) versus sarcopenic and malnourished elderly (SME). In total, 107 HE ( n = 54 men, n = 53 women) and 261 SME ( n = 101 men, n = 160 women) performed three maximal concentric isokinetic knee extension and flexion repetitions at 60°·s -1 and 180°·s -1 . PT for Repetition 3 was lower than Repetitions 1 and 2, while MP for Repetition 1 was lower than Repetitions 2 and 3 in SME. Intraindividual variability among repetitions was correlated with strength, but not age, and was greater in SME, during knee flexion, and at 180°·s -1 . Velocity-related decreases in PT from 60°·s -1 to 180°·s -1 were more pronounced in SME. In summary, (a) the repetition with the highest PT value may be the best indicator of maximal strength, while the average may indicate strength maintenance in SME; (b) intraindividual variability among repetitions reflects functional decrements from HE to SME; and (c) decreases in PT from 60°·s to 180°·s may reflect greater losses of fast-twitch (type II) fiber function.

  16. Comparison of isokinetic muscle strength and muscle power by types of warm-up.

    PubMed

    Sim, Young-Je; Byun, Yong-Hyun; Yoo, Jaehyun

    2015-05-01

    [Purpose] The purpose of this study was to clarify the influence of static stretching at warm-up on the isokinetic muscle torque (at 60°/sec) and muscle power (at 180°/sec) of the flexor muscle and extensor muscle of the knee joint. [Subjects and Methods] The subjects of this study were 10 healthy students with no medically specific findings. The warm-up group and warm-up with stretching group performed their respective warm-up prior to the isokinetic muscle torque evaluation of the knee joint. One-way ANOVA was performed by randomized block design for each variable. [Results] The results were as follows: First, the flexor peak torque and extensor peak torque of the knee joint tended to decrease at 60°/sec in the warm-up with stretching group compared with the control group and warm-up group, but without statistical significance. Second, extensor power at 180°/sec was also not statistically significant. However, it was found that flexor power increased significantly in the warm-up with stretching group at 180°/sec compared with the control group and warm-up group in which stretching was not performed. [Conclusion] Therefore, it is considered that in healthy adults, warm-up including two sets of stretching for 20 seconds per muscle group does not decrease muscle strength and muscle power.

  17. Validity of trunk extensor and flexor torque measurements using isokinetic dynamometry.

    PubMed

    Guilhem, Gaël; Giroux, Caroline; Couturier, Antoine; Maffiuletti, Nicola A

    2014-12-01

    This study aimed to evaluate the validity and test-retest reliability of trunk muscle strength testing performed with a latest-generation isokinetic dynamometer. Eccentric, isometric, and concentric peak torque of the trunk flexor and extensor muscles was measured in 15 healthy subjects. Muscle cross sectional area (CSA) and surface electromyographic (EMG) activity were respectively correlated to peak torque and submaximal isometric torque for erector spinae and rectus abdominis muscles. Reliability of peak torque measurements was determined during test and retest sessions. Significant correlations were consistently observed between muscle CSA and peak torque for all contraction types (r=0.74-0.85; P<0.001) and between EMG activity and submaximal isometric torque (r ⩾ 0.99; P<0.05), for both extensor and flexor muscles. Intraclass correlation coefficients were comprised between 0.87 and 0.95, and standard errors of measurement were lower than 9% for all contraction modes. The mean difference in peak torque between test and retest ranged from -3.7% to 3.7% with no significant mean directional bias. Overall, our findings establish the validity of torque measurements using the tested trunk module. Also considering the excellent test-retest reliability of peak torque measurements, we conclude that this latest-generation isokinetic dynamometer could be used with confidence to evaluate trunk muscle function for clinical or athletic purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Improving strength and postural control in young skiers: whole-body vibration versus equivalent resistance training.

    PubMed

    Mahieu, Nele N; Witvrouw, Erik; Van de Voorde, Danny; Michilsens, Diny; Arbyn, Valérie; Van den Broecke, Wouter

    2006-01-01

    Several groups have undertaken studies to evaluate the physiologic effects of whole-body vibration (WBV). However, the value of WBV in a training program remains unknown. To investigate whether a WBV program results in a better strength and postural control performance than an equivalent exercise program performed without vibration. Randomized, controlled trial. Laboratory. Thirty-three Belgian competitive skiers (ages = 9-15 years). Subjects were assigned to either the WBV group or the equivalent resistance (ER) group for 6 weeks of training at 3 times per week. Isokinetic plantar and dorsiflexion peak torque, isokinetic knee flexion and extension peak torque, explosive strength (high box test), and postural control were assessed before and after the training period. Both training programs significantly improved isokinetic ankle and knee muscle strength and explosive strength. Moreover, the increases in explosive strength and in plantar-flexor strength at low speed were significantly higher in the WBV group than in the ER group after 6 weeks. However, neither WBV training nor ER training seemed to have an effect on postural control. A strength training program that includes WBV appears to have additive effects in young skiers compared with an equivalent program that does not include WBV. Therefore, our findings support the hypothesis that WBV training may be a beneficial supplementary training technique in strength programs for young athletes.

  19. Microscopic analysis of homogeneous electron gas by considering dipole-dipole interaction

    NASA Astrophysics Data System (ADS)

    Bordbar, G. H.; Pouresmaeeli, F.

    2017-12-01

    Implying perturbation theory, the impact of the dipole-dipole interaction (DDI) on the thermodynamic properties of a homogeneous electron gas at zero temperature is investigated. Through the second quantization formalism, the analytic expressions for the ground state energy and the DDI energy are obtained. In this paper, the DDI energy has similarities with the previous works done by others. We show that its general behavior depends on density and the total angular momentum. Especially, it is found that the DDI energy has a highly state-dependent behavior. With the growth of density, the magnitude of DDI energy, which is found to be the summation of all energy contributions of the states with even and odd total angular momenta, grows linearly. It is also found that for the states with even and odd total angular momenta, the DDI energy contributions are corresponding to the positive and negative values, respectively. In particular, an increase of total angular momentum leads to decline in the magnitude of energy contribution. Therefore, the dipole-dipole interaction reveals distinct characteristics in comparison with central-like interactions.

  20. The biomechanics of concussion in unhelmeted football players in Australia: a case-control study.

    PubMed

    McIntosh, Andrew S; Patton, Declan A; Fréchède, Bertrand; Pierré, Paul-André; Ferry, Edouard; Barthels, Tobias

    2014-05-20

    Concussion is a prevalent brain injury in sport and the wider community. Despite this, little research has been conducted investigating the dynamics of impacts to the unprotected human head and injury causation in vivo, in particular the roles of linear and angular head acceleration. Professional contact football in Australia. Adult male professional Australian rules football players participating in 30 games randomly selected from 103 games. Cases selected based on an observable head impact, no observable symptoms (eg, loss-of-consciousness and convulsions), no on-field medical management and no injury recorded at the time. A data set for no-injury head impact cases comprising head impact locations and head impact dynamic parameters estimated through rigid body simulations using the MAthematical DYnamic MOdels (MADYMO) human facet model. This data set was compared to previously reported concussion case data. Qualitative analysis showed that the head was more vulnerable to lateral impacts. Logistic regression analyses of head acceleration and velocity components revealed that angular acceleration of the head in the coronal plane had the strongest association with concussion; tentative tolerance levels of 1747 rad/s(2) and 2296 rad/s(2) were reported for a 50% and 75% likelihood of concussion, respectively. The mean maximum resultant angular accelerations for the concussion and no-injury cases were 7951 rad/s(2) (SD 3562 rad/s(2)) and 4300 rad/s(2) (SD 3657 rad/s(2)), respectively. Linear acceleration is currently used in the assessment of helmets and padded headgear. The 50% and 75% likelihood of concussion values for resultant linear head acceleration in this study were 65.1 and 88.5 g, respectively. As hypothesised by Holbourn over 70 years ago, angular acceleration plays an important role in the pathomechanics of concussion, which has major ramifications in terms of helmet design and other efforts to prevent and manage concussion. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

Top